Lab. Vapor Pressure

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4
At a glance
Powered by AI
Vapor pressure increases as temperature increases according to the Clausius-Clapeyron equation. The enthalpy of vaporization can be calculated from the slope of a plot of ln(P) vs 1/T.

The Clausius-Clapeyron equation relates the natural log of vapor pressure to the inverse of temperature, with the slope of the line yielding the enthalpy of vaporization. Three key assumptions are that the enthalpy of vaporization is constant with temperature and pressure, the volume of the liquid is negligible compared to the gas, and the gas behaves ideally.

Three key assumptions are made: 1) the enthalpy of vaporization is constant and independent of temperature and pressure, 2) the volume of the liquid is negligible compared to the gas, and 3) the change in volume is given by the ideal gas law.

Vapor Pressure and

Enthalpy of Vaporization
When a liquid is placed in a container, and the container is sealed tightly, a portion of the liquid
will evaporate. The newly formed gas molecules exert pressure in the container, while some of
the gas condenses back into the liquid state. If the temperature inside the container is held
constant, then at some point equilibrium will be reached. At equilibrium, the rate of condensation
is equal to the rate of evaporation. The pressure at equilibrium is called vapor pressure, and will
remain constant as long as the temperature in the container does not change.
This equilibrium relationship between vapor and liquid can be derived from the thermodynamic
master equation.
(1)

dG = VdP SdT

If the liquid and vapor phases are at equilibrium with one another, then G = 0. Rearranging the
master equation and substituting in the equation for the change of entropy for vaporization gives
a general equation for phase transitions:
(2)

S = Hvap / T

(3)

dP =

H m,Trans
TVm

dT

Equation (3) can be solved by making the assumption that the enthalpy of transition is
independent of T & P, and that the change in volume can be attributed solely to the ideal gas
volume. With these assumptions in place, the Clausius-Clapeyron equation describes how
vapor pressure changes with changes in temperature, as well as describes how the enthalpy of
vaporization affects those changes.
(4)

ln

P2 H vap
=
P1
R

1 1

T2 T1

P = vapor pressure, T is Kelvin temperature, Hvap is the molar enthalpy of vaporization, and R
is the universal gas constant (in units of J/K*mol).
If we let P1 and T1 be fixed and equal to the values for standard conditions (Po = 1bar, Tovap =
standard boiling point), then equation (4) can be re-written for other T & P conditions as

H vap

(5)

ln P =

(6)

C = constant =

Gentry, 2011

RT

+C
+ H vap
o
vap

RT

+ ln( P o )

(solving for To, Po=1bar)

Theoretical equations are only as good as the assumptions made to derive them. In this case, the
three principal assumptions are that:
1) Hvap is constant, independent of both T and P,
2) The volume of the liquid is negligible compared to the volume of the gas, and
3) V is given by the volume of an ideal gas.
If the gases do not obey the ideal gas law, then we must correct the Clausius-Clapeyron equation
using a real gas equation such as compressibility.
(7)

Z Vactual / Videal

(8)

ln P =

H vap
Z RT

or Vactual = Z nRT/P

+C

One method we can use to estimate the compressibility factor is the Berthelot equation.
(9)

9 PTc
Z = 1+
128 Pc T

1 6 Tc

where Tc and Pc are the critical temperature and pressure of the liquid taken from the literature.
[for example, http://webbook.nist.gov/chemistry]
It should be pointed out that the Clausius-Clapeyron equation also assumes that Hvap is
independent of temperature. In reality we know that the enthalpy of transition changes as you
move away from the standard vaporization temperature. This is due to there being differences in
the heat capacities for solids and liquids.
(10)

o
H vap (T ) = H vap
+ o (C p ,vapor C p ,liquid ) dT
T

We will be applying the assumption of Hvap=constant over only a small temperature range, so
errors due to the assumption should be small.

OBJECTIVES
In this experiment, you will introduce a specific volume of a volatile liquid into a closed vessel,
and measure the pressure in the vessel at several different temperatures. Since there will be
residual air in the vessel as well, you will need to use Daltons Law of Partial Pressure to extract
the vapor pressure from the observed pressure.
By analyzing your measurements, you will be able to calculate the relationship between Pvap and
T and calculate the Hvap of the liquid.

-2-

PROCEDURE
1. CAUTION: The alcohol used in this experiment is flammable. Be sure that there are no open
flames in the room during the experiment. Notify your teacher immediately if an accident
occurs.
2. Connect a Gas Pressure Sensor to Channel 1 of the Vernier computer interface. Connect a
Temperature Probe to Channel 2 of the interface. Connect the interface to the computer with
the proper cable. Use the clear tubing to connect the white rubber stopper to the Gas
Pressure Sensor. (About one-half turn of the fittings will secure the tubing tightly.)
3. Pour 3-5mL of ethanol into an Erlenmeyer flask. Then insert the white stopper snugly into
the neck of the Erlenmeyer flask to avoid losing any of the gas that will be produced as the
liquid evaporates. Important: Close the valve on the white stopper.
4. Put the stoppered flask in an empty 1 liter beaker that you will later use as a temperature
bath. Include a magnetic stir bar so that the liquid can be mixed during the warming process.
5. Start the Logger Pro program on your computer. Open the file 34 Vapor from the
to begin data collection.
Advanced Chemistry with Vernier folder. Click
6. When the readings stabilize, click
. We will use this room-temperature pressure later
to insure that we do not have a gas leak at the top of the flask.
7. AFTER taking a room temperature pressure reading, add ice and water to cover the flask up
to the bottom of the stopper. Place the Temperature Probe in the ice bath as well. Monitor
the pressure and temperature readings. When the pressure and temperature readings
stabilize, click
to record the readings.
8. Use the hot plate to start warming your water bath. Do not take any further measurements
(other than the initial ice bath pressure) until all of the ice has melted and sufficient mixing
has taken place to get uniform temperature across the bath. [You can physically remove
most of the ice and replace with cold water to speed the process.]
9. Continue to slowly warm the system, taking temperature/pressure measurements every 35C. *** Note the word slowly you want to insure enough time that the temperature of
the liquid and vapor inside the flask remains in equilibrium with the temperature of the
surrounding water bath.
You should have observed a pressure drop when you put the system in ice, and you should
have recovered the initial pressure when you got back close to room temperature. If either of
these fails to happen, you likely have a pressure leak in your apparatus.
10. Repeat Step 12 until your temperature approaches 40C. Do not warm the water bath
beyond 40C because the pressure increase may pop the stopper out of the flask. If you must
remove some of the water in the bath, do it carefully so as not to disturb the flask.
Let me repeat that. The stoppers on the flasks are not very secure. The easiest way to have
problems is to let gas escape from the stoppers. This will occur if there is too much jostling,
especially at higher temperatures where there is excess pressure inside the flask.
11. After you have completed your readings, click
to end the data collection. Record the
various temperatures and pressures in your lab book. Do not exit Logger Pro until your data
are recorded.

-3-

DATA ANALYSIS
1. Since air was present in the flask before the ethanol was added, the observed pressure inside
the flask was a combination of air pressure and ethanol vapor pressure. We therefore need
to correct for this air pressure. We know from Daltons Law of Partial Pressure that Ptot = Pair
+ PEtOH. You should be able to browse the internet to find the vapor pressure of ethanol as a
function of temperature. Use these literature data to interpolate a value of PEtOH at your
lowest temperature. Use Daltons Law to determine Pair at this temperature. You can then
use the ideal gas law to adjust Pair at your other temperatures.
Calculate the resultant vapor pressures for ethanol, PEtOH, (in bar) as a function of
temperature.
2. The Clausius-Clapeyron equation says that a plot of ln(P) vs. (1/T) should have a linear
relationship with one another.
(a) What are the expected parametric expressions for the slope and the intercept for your
data?
(b) Using linear regression, obtain your experimental values for slope and intercept and use
the slope to calculate your experimental heat of vaporization.
3. Compare your experimental heat of vaporization to a literature value for ethanol
4. Use the Clausius-Clapeyron equation to extrapolate your data and find the normal boiling
point. How does your number compare to the literature value? Comments?
5. The assumption was made that ethanol behaves like an ideal gas. Using Eqn. 9, what is the
calculated compressibility, Z, for ethanol at 298K? If you use this to correct for your
calculations, what is your corrected heat of vaporization? (Assume that Z stays constant over
the temperature range that we looked at.)
6. The assumption was made that Hvap is independent of temperature. Using the literature
value for the standard heat of vaporization, what is the change in Hvap when going from
298K to 273K, given that the heat capacities for ethanol are Cp,liq = 112 J/mol*K and Cp,gas =
65.2 J/mol*K? [Note that you must first calculate each Hvap compared to the standard
vaporization temperature for ethanol.]