The document provides calculations for footing sizing and column loads for four columns supporting the Keystone Library. It is determined that the existing footing sizes of 49 square feet are insufficient for Columns 3 and 4, which require 54 and 59.625 square feet respectively. Interior and exterior girder designs are also analyzed, with wide flange steel sections selected based on moment, shear, and deflection requirements.

Uploaded by

api-260940359
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
13K views5 pages

3 2 10documentation

The document provides calculations for footing sizing and column loads for four columns supporting the Keystone Library. It is determined that the existing footing sizes of 49 square feet are insufficient for Columns 3 and 4, which require 54 and 59.625 square feet respectively. Interior and exterior girder designs are also analyzed, with wide flange steel sections selected based on moment, shear, and deflection requirements.

Uploaded by

api-260940359
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 5

Seth Dilday

11/4/2016

Footing Analysis for Keystone Library


Designer: Seth Dilday, Axel Nava, Gabriel Nava

Seth Dilday
11/4/2016

Column Load Calculations


Column 2: (25800 * 2) + (51600 * 2) = 154800 lbs
Column 3: 12* 30 (50) = 18000 lbs
18000 lbs + 154800 = 172800 lbs
Column 4: (24*30) (50) = 36000 lbs
36000 lbs + 154800 = 190800 lbs
Soil Bearing Pressure Calculations
Footing dimensions = 84 x 84 x 24
Soil Bearing Pressure = 3500 psf
2 * 150 lbs/ft^3 = 300 psf
3500 psf - 300 psf = 3200 psf
Required Footing Area Calculations
Column 2:
154800 lbs/ 3200 psf = 48.375 sf
Column 3:
172800 lbs/ 3200 psf = 54 sf
Column 4:
190800 lbs/ 3200 psf = 59.625 sf
Comparison of Required Area to Existing Area
Column 2:
49 >= 48.375 :)
Column 3:
49 <= 54 :(
Column 4:
49 <= 59.625 :(
New Footing Size

Seth Dilday
11/4/2016
Column 3:
Required dimensions are 7.35 x 7.35
Column 4:
Required dimensions are 7.73 x 7.73

Interior Girder Calculations


Include the loading and beam diagrams.
18009
Calculate the end reaction and maximum moment.
18009
120120.03
Calculate the required nominal moment.
200600.4501
Determine the required plastic section modulus and select an efficient wide flanges
48.144
W12x35
Check the shear strength.
27013.5
112500
Calculate deflection limits.
1
2/3
Calculate actual deflections.
1.06
Select a final design.
w16x31
Exterior Girder Calculations
1. Include the loading and beam diagrams.
9000.4

Seth Dilday
11/4/2016
2. Calculate the end reaction and maximum moment.
9000.4
60,032.668

3. Calculate the required nominal moment.


100,254.555
4. Determine the required plastic section modulus and select an efficient wide flange.
24.0610933
W12x19
5. Check the shear strength.
13500.6
85,728
6. Calculate deflection limits.
1
2/3
7. Calculate actual deflections.
1.17 :(
W12x22 .976
.651
8. Select a final design
W12x22

Seth Dilday
11/4/2016