Installation Guide: N5101A Baseband Studio PCI Card

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

Installation Guide

N5101A Baseband Studio PCI Card


Overview
This guide provides instructions on how to install the N5101A Baseband Studio PCI card in a PC. The PCI card is
installed in a PC and is used with a signal source (or an N5515C wireless communications test set) to run Agilent
software applications. This process comprises the following steps:
1. Verify that the hardware you received is correct, and note the license and serial number of each Baseband Studio
PCI card (see page 2).
2. Ensure that your PC and signal source meet the basic installation requirements (see page 4 and page 5).
3. Install the PCI card hardware (for the internal PCI card hardware, see page 6; for external cabling, see page 8).
4. Install the Baseband Studio PCI card driver (see page 9).
After the PCI card installation is complete, the procedure directs you to the software installation guide for instructions
on installing application software used with the PCI card (see page 9).
This document also provides troubleshooting tips (see page 13), application-specific cabling information (see page 14),
Agilent assistance information (see page 15), and a list of additional PCI card-related documentation (see page 16).
NOTE

The Baseband Studio PCI card shown in this document reflects the current PCI card that is being
shipped. Older versions of the PCI card appear considerably different. However, all connectors are
located in the same location as the board shown in this document.

NOTE

A declaration of conformity is on file for the N5101A Baseband Studio PCI card and is available
upon request.

Agilent Part Number: N5101-90001


Printed in USA

January 2005

Agilent Technologies, Inc. 2003 2005

Checking the Shipment


Hardware
For each N5101A Baseband Studio PCI card purchased, you should receive the following items:
Table 1

PCI Card Parts List

1 N5101A Baseband Studio PCI Card

5 Digital Bus Cable (P/N N5101-60003)

2 Installation Guide (P/N N5101-90001)


(This manual. Formerly the Quick Start Guide.)

6 Loopback Fixture (P/N E4400-63583)


(For troubleshooting)

3 GPIO Bracket (P/N N5101-60006)


(Replaceable Parts of GPIO Bracket:
- SMB-to-MCX Cable: P/N 8121-0655
- Ribbon Cable Assembly: P/N N5101-60004)

7 PCI card ISA Retainer & Screws


Retainer: P/N 1400-3295
Screws: P/N 0624-0858 (2 each)

4 SMB to SMB Cables (P/N 8120-5020) (2 each)


(For installation of two PCI cards)

8 Foam Pad (P/N N5101-20005)


(For installation of two PCI cards)

Note: Although the Baseband Studio CD (P/N N5101-90002) is no longer shipped with the product, this installation
guide provides instructions and information for downloading the software that the CD provided in case you no
longer have the documentation that accompanied the CD.

N5101-90001

Entitlement Certificate
Each software application purchase includes one entitlement
certificate. Software applications require a license file to be fully
functional. The entitlement certificate shipped with your application
purchase lists the products purchased, and has two of the four numbers
required to obtain the license file.
Applications are licensed to a specific PCI card; you may
license more than one application to a single PCI card. The
N5101A Baseband Studio PCI card has the other two
numbers needed to obtain the license file.
The license redemption process is described later in the
installation procedure.
From the PCI card, you will need the following numbers. It is
important to record and save these numbers now to avoid the need to
remove your PCI card from the computer later in the installation
procedure.

PCI Card Bar Code License Number


A bar code label that displays this license number is affixed to the PCI card as shown below.
Record the license number here:

Instrument (Model) Serial Number


A label that displays the serial number is affixed to the reverse side of the PCI card as shown below. The serial
number is also displayed on a sticker affixed to the end of the box in which the card is packaged.
Record the serial number here:

Instrument
(Model)
Serial
Number

PCI Card
Bar Code
License
Number

N5101-90001

System Requirements
PC Requirements
Requirements for all applications:

You must be able to log on to your PC using an account with administrative privileges.

The PC and all signal sources must be connected via LAN or GPIB.

Available PCI slot(s) must meet the 2.2 PCI/ISA (or later) specifications (see the bottom of page 13).

Not all computer cases are PCI or ISA compliant. PCI compliant computer cases accommodate the N5101A PCI
card with the metal extender, thus enabling both ends to be restrained. For ISA compliant computer cases, an ISA
retainer (included) must be attached to the N5101A PCI card metal extender to enable the card to fit into the ISA
slots. To avoid reliability issues, the N5101A PCI card must be restrained on both ends. Refer to page 6 for
installation instructions.

Application-specific requirements:
Table 2

N5110A Baseband Studio for Waveform Streaming


Streaming Rate
Slow (5 MSa/s)

Medium (20 MSa/s)

Fast (40 MSa/s)

Processor

Pentium 4, 2 GHz or greater

Pentium 4, 2 GHz or greater

Pentium 4, 2 GHz or greater

Front Side Bus

400 MHz

533 MHz

533 MHz

Memory
(Size, Type)

512 MB, PC2100

1 GB, PC2700

2 GB, PC2700

Available
PCI Slots

1: 32 bit/33 MHz and 1 additional


PCI slot opening

1: 64 bit/66 MHz and 1 additional


PCI slot opening

1: 64 bit/66 MHz or 1: 64 bit/133


MHza and 1 additional PCI slot
opening

HDD
Controller

Generic IDE

Ultra 160 SCSI RAID Controller

Ultra 320 SCSI RAID Controller

Hard Disks

1: Ultra ATA (7200 RPM)

2: Ultra 160 SCSI (10K RPM)

5: Ultra 320 SCSI (15K RPM)

HDD
Configuration

Single Drive with OS + Data

Dual Drive with OS + Data

Dedicated OS Drive, Data on


RAID

Operating
System

Windows 2000 Professional,


SP 3

Windows 2000 Professional, SP 3

Windows 2000 Professional, SP 3

Example

HP XW4100

HP XW8000

HP XW8000 w/add-on HDDs

a. Required for the RAID Controller

N5101-90001

Table 3

N5110B Baseband Studio for Waveform Capture and Playback

Processor

Pentium III, 800 MHz or greater

Memory (RAM)

256 MB minimum

Free Disk Space

200 MB minimum

Available PCI Slots

One 32 bit/33 MHz and one additional PCI slot opening

Operating System

Windows XP Professional, SP 1 or greater -or- Windows 2000 Professional, SP 3 or greater

Table 4

N5115A Baseband Studio for Fading

Processor

Pentium III, 600 MHz or greater

Memory (RAM)

256 MB minimum

Free Disk Space

145 MB minimum

Available PCI Slots

Single-Channel Configuration: One 32 bit/33 MHz and one additional PCI slot opening
Dual-Channel Configuration: Two 32 bit/33 MHz and two additional PCI slot openings

Operating System

Windows XP Professional, SP 1 or greater -or- Windows 2000 Professional, SP 3 or greater

Signal Source Requirements


The PC and signal sources must be connected via LAN or GPIB.
Table 5

Requirements for Signal Sources

Application
N5110B Baseband Studio
for waveform capture and
playback

Source Model

Source Firmware Revision

Source Options

Interface

601 or 602

LAN or GPIB

E8267D

C.04.04

E8767C

C.03.78 or later

602

LAN or GPIB

E4438C

C.03.74 or later

601 or 602

LAN or GPIB

N5110A Baseband Studio


for waveform streaming

E8267C

C.03.31 or later

602

LAN or GPIB

E4438C

C.03.30 or later

601 or 602

LAN or GPIB

N5115A Baseband Studio


for fading

E4438C

C.03.40 or later

601 or 602

LAN or GPIB

E5515C

E6702B:B.03.00 or later,
E6703C:C.01.00 or later, or
E6785C: C.01.00 or later

003
E5515CU Option 504
E5515CU Option 187a

GPIB only

a. E5515CU Option 187 required for W-CDMA usage only.

N5101-90001

Installing the Hardware


PC Hardware and Internal Cables
All Applications:
Power down the PC and disconnect the AC power cable.
Before you install the Baseband Studio PCI card, be sure to note the bar code license number and the model serial
number on the card (described on page 3).
NOTE

The N5101A PCI card is a 64-bit card. If you are using the streaming application from a hard disk a
64-bit slot is required. Otherwise, a 32-bit slot may be used without loss of functionality.

Single-card Installation:
Internal cabling:

1. Connect the GPIO bracket ribbon cable to J3 on the PCI card. The remaining cables can be connected, as shown,
either before or after you install the PCI card in the computer.
Number on
GPIO Bracket
4
5
6
7
8

PCI Card
Connector
J10
J11
J12
J3
J13

SMB-to-MCX Cables
Numbers on
GPIO Bracket
4
5

J13

J10

6
J12
J11

Caution: Use standard


precautions to protect
against electrostatic
discharge when handling
the PCI card.

8
Ribbon
Cable

J3

For connector visibility, the PCI card


is shown without its metal shielding.

2. For PCI compliant computer cases, install the N5101A PCI card and GPIO bracket using two PCI slots in the PC.
Refer to the PCs documentation for specific installation instructions.
PC Rear
Panel

N5101A PCI Card

GPIO Bracket

N5101-90001

3. Ensure that the metal shielding bracket of the PCI card slips into the PCI slot at the front of the case. If it does not
fit, refer to step 4.

PCI Slots
near the front
of the PC

4. For ISA-compliant computer cases, attach the metal extender bracket to the PCI card shielding using the two
screws provided. See the illustration below. The extender will slip into the guides at the front of the ISA-compliant
PC case as shown in the illustration above.

Screw
Card Shielding
Extender

5. Secure the rear of the PCI board (the end with the digital bus connector) to the PC chassis with a mounting screw.
6. Reconnect the AC power cable.
7. If the LAN/GPIB was disconnected, reconnect it.

N5101-90001

Two-card Installation:
Before you install the PCI cards in the PC for the dual-channel fading application, attach the foam pads approximately
1 inch from the top of the PCI card as shown in Figure A of the following illustration.
If the PCI/ISA slots are such that the two cards must be installed side-by-side (as in Figure B), you may need to route
one or both of the ribbon cables under the PCI cards to connect them. This does not damage the cables.
Figure A

Figure B
PCI Card B
Foam
Pad

Back Top
Front Top

1"
Foam
Pad

PCI Card A

Foam Pads

External Cables
Install the digital bus cable for all applications.

1. Inspect the digital bus cable and connectors to ensure that they are clean.
2. Connect a digital bus cable between each N5101A Baseband Studio PCI card and a source (or N5102A Baseband
Studio digital signal interface module), connecting the end of the cable with the EMI suppressor to the source.
Source
Computer

EMI Suppressor:
Connect this end of the
cable to the source.

NOTE

The digital bus cable connector has a release latch on each side. As you make a connection, you must
simultaneously squeeze these release latches (see the illustration below); the connector should snap
into place. A securely connected cable does not come loose when gently pulled.

To disconnect the cable, squeeze the release latches as you remove the connector.

N5101-90001

Installing the Software

If you received a CD-ROM with your N5101A PCI card, follow the instructions in Installing the Baseband Studio
Software using the CD-ROM on page 10 to install your software.

If you do not have a PCI card CD-ROM or if you want to install the most recent Baseband Studio application
version, follow the instructions in this section to install your software.

PCI Card Driver


1. Go to the Agilent Technologies web site: http://www.agilent.com/find/basebandstudio.
2. Click the N5101A product link.

3. On the N5101A Baseband Studio PCI Card page, click the Baseband Studio PCI Card Driver link and follow the
download instructions.

Application Software
To install the Baseband Studio application software, refer to the Agilent Technologies Software (for Baseband Studio
and Signal Studio) Installation Guide (part number E4400-90559). This document leads you through installing the
Baseband Studio software applications. To access this document:
1. Go to the Agilent Technologies web site:

http://www.agilent.com/find/basebandstudio

2. Click the product link for the Baseband Studio application that you wish to download.

3. On the Baseband Studio application page, click the link for the software installation guide and follow the download
instructions. Print this document.

N5101-90001

Installing the Baseband Studio Software using the CD-ROM


The Baseband Studio software CD-ROM is no longer shipped with the N5101A Baseband Studio PCI card. The most
recent versions of the Baseband Studio applications are only available by downloading them from the Agilent web site.
If you have the Baseband Studio software CD-ROM, you can install the older Baseband Studio versions of fading and
waveform streaming without downloading them from the Agilent web site. This section contains the instructions for
installing these older applications using the CD-ROM.

Licensing the Software


Baseband Studio applications require a license file to be fully functional. You will need to provide the following
information to obtain the license file.
From the entitlement certificate:

Order Number
Certificate Number

From the N5101A PCI carda:

PCI card Bar Code License Number


Instrument (Model) Serial Number (optional)

a. Applications are licensed to a specific PCI card; you may license more than one application to a given PCI card.
Refer to page 3 for the location of the bar code license number and the serial number.

1. Go to http://www.agilent.com/find/softwarelicense and follow the software license redemption process to obtain


your license file. The license file will be e-mailed to you promptly.
2. Copy the file into the following program directory: C:\Program Files\Agilent\Baseband Studio\LicenseFiles

3. Make a back-up copy of the license file and store it in a safe place. You will need this back-up file if the license file
is lost or erased.

Installing the Software


1. If not already done, reconnect the AC power cable and turn on the PC.
The PCs Found New Hardware wizard prompts you for a suitable driver, which is located on the Baseband Studio
Software CD.
2. Insert the software CD into your PCs CD-ROM drive.
3. In the Found New Hardware wizard, click Next.
Follow the instructions in this wizard, and accept the driver N5101A.inf. If the wizard does not find the driver
automatically, browse the driver folder on the CD and select it.
4. Locate AgilentBasebandStudioInstall.exe on the CD and run it. The Agilent Baseband Studio-InstallShield Wizard
appears; click Next, and follow the setup instructions. The Baseband Studio PCI card software installs.
5. If not already done, configure Agilent IO Libraries to include the signal source.
See Configuring the Vector Signal Generator Using the LAN Interface on page 11 for an example using the LAN
interface. Signal sources connected using GPIB are configured in a similar manner.
6. Run the Baseband Studio IO Config utility: This utility provides the system configuration and verification required
by Baseband Studio applications.
Start > Programs > Agilent Baseband Studio > Baseband Studio IO Config > IO Config
Follow the on-screen instructions. For details on using this utility, refer to the utilitys help. Run this utility
whenever you make a change that could affect the configuration of the Baseband Studio PCI cards and instruments.

10

N5101-90001

7. After the Baseband Studio software is installed and configured, copy the license file into the directory:
C:\Program Files\Agilent\Baseband Studio\LicenseFiles
For details on obtaining a license file, see Licensing the Software on page 10; for details on using a license file
with an application, refer to the Baseband Studio IO Config help, and the help in the individual applications.
8. Run the Baseband Studio applications (found in the Agilent Baseband Studio directory).
When you initially run a Baseband Studio application, it looks for the required license file.

Configuring the Vector Signal Generator Using the LAN Interface


Direct LAN Connection between PC and Vector Signal Generator:
A direct connection between the PC and a vector signal generator requires a LAN crossover cable. In this case, first do
the following:

1. Select Start > Settings > Network & Dialup Connections.


2. Right-click on the Local Area Connections icon, and select Properties.
3. Select Internet Protocol and click Properties.
4. Click Use the following IP address, and enter the vector signal generators IP address (adding 1 to the last digit),
subnet mask, and default gateway.

5. Click OK, OK.

N5101-90001

11

All Configurations:
1. Run the Agilent IO Libraries IO Config program: Start > Programs > Agilent IO Libraries > IO Config
2. If no interfaces are configured, click Auto Config.
3. Select TCPIP LAN Client (LAN
Instrument).
4. Select TCPIP0 and click Edit.

5. Click Edit VISA.


6. Click Add Device.
7. Enter the signal sources IP
address; a device name is not
required.

8. Click OK, OK, OK, OK to close IO


Config windows.

9. As verification, run the Agilent IO


Libraries Visa assistant program:
Start > Programs >
Agilent IO LIbraries > Visa
Assistant.

10. In the left pane, select the


instrument you just configured; in
the right pane, click the
Formatted I/O tab.

11. Click the SCPI Instr. Lang. radio


button, then the *IDN? button.
Your instruments model and serial
number should appear.

12. Select File > Exit.

12

N5101-90001

Troubleshooting
The Found New Hardware wizard is not displayed
If an N5101A Baseband Studio PCI card was previously installed, you may see a slightly different dialog from the New
Hardware Detected wizard. If this happens, select the file N5101A.sys from the driver directory on the Baseband Studio
CD, rather than the N5101A.inf file.

No Prompt for the N5101A Baseband Studio PCI card driver


If you are not prompted for the N5101A Baseband Studio card driver, turn off the PC and ensure that the PCI card is
securely seated in its slot. Reboot the PC, and log on using an account with administrative privileges.

N5101A Baseband Studio PCI card does not appear in the IO Config utility Select an N5101A List
Ensure that all N5101A Baseband Studio PCI cards are installed correctly:

1.
2.
3.
4.

On the PC desktop, right-click the My Computer icon.


Select Properties.
Click the Hardware tab.
Click Device Manager.
Under Agilent Technologies Test & Measurement Devices, you should see at least one Agilent N5101A listed.
5. Right-click an Agilent Technologies N5101A icon and select Properties.
In the Device status area, you should see the message, This device is working properly. If not, the
N5101A Baseband Studio PCI card is probably not seated properly in the PC.

N5101A PCI Card-PC Installation Compatibility Issues

PCI Long Card


Some PCs will have front card guides in the plane of the N5101A PCB which will support the front edge of the
metal extension plate on the N5101A card. These front card guide slots will be about 305 mm (12 inches) from the
rear card mounting surface and in line with the PCI connector. The N5101A PCB with the installed front metal
plate is compliant with the PCI long card specification. The overall card length is 312 mm (12.283 inches).

ISA Long Card


Some PCs will have ISA-compliant front card guides. These ISA front card guide slots will be about 335 mm
(13 inches) from the rear card mounting surface and offset from the plane of the N5101A PCB and PCI connector
by 14.27 mm (0.562 inches). An ISA retainer (an adaptor with two mounting screws) must be installed onto the
N5101A metal extension plate to support the front of the card.

PC Slot Too Short for N5101A PCI Card


The N5101A front metal extension plate may be removed. If the PC slots are still too short, a PC with PCI or ISA
long card compliant slots is recommended.

N5101-90001

13

Application-Specific Cabling
N5110A Baseband Studio for Waveform Streaming/N5110B Baseband Studio for
Waveform Capture and Playback, External Triggering
The GPIO bracket accepts an input trigger (Start), and
provides two output markers (Ready and Underflow).
For details, refer to the applications help.

Start
Ready
Underflow

N5115A Baseband Studio for Fading, Dual Channel


Recommended Setup:
Connect three SMB-to-SMB cables between the two GPIO brackets as shown. The cables are connected as follows:
Connector on
Master
GPIO Bracket

Connect to

GPIO Bracket
Connector

Slave 8

Master 8

Slave 5

Slave
Master

Alternate Setup:
If you are using two PCI cards for dual-channel fading and your PC has fewer than four open PCI slots, you can
connect the PCI cards internally using three MCX-to-MCX cables (Agilent part number 8121-0620). These cables are
not provided with the PCI card. The cables have MCX (male) connectors on both ends. They are connected as shown
below:
From Master
PCI Card

Connect to

PCI Card

J13

Master J11

J10

Slave J13

J12

Slave J11
Slave PCI Card

Note: Cabling is not connected to connectors


J10 and J12 on the Slave PCI card.

Master PCI Card


J11 J12 J10 J13

14

N5101-90001

Getting Assistance from Agilent


Your local Agilent office can help you with your test and measurement needs. The following Internet URL provides the
information you need to contact your local Agilent office: http://www.agilent.com/find/assist
If you do not have access to the Internet, please contact your field engineer.
NOTE

N5101-90001

In any correspondence or telephone conversation, refer to the product by its model number and full
serial number. With this information, the Agilent representative can determine whether your product is
still within its warranty period.

15

Additional PCI Card-Related Documentation


The following list of PCI card-related documentation is available from the Agilent web site (http://www.agilent.com).
The easiest method of finding this documentation is using the Agilent web site search tool to search for the document
part number.

Agilent N5101A Baseband Studio PCI Card Memory Upgrade Installation Note
Agilent part number: N5101-90003

Agilent Technologies Software Installation Guide for Baseband Studio and Signal Studio
Agilent part number: E4400-90559

Agilent Technologies E5515C Fading Solution Application Guide


Agilent part number: 1000-1894
http://cp.literature.agilent.com/litweb/pdf/1000-1894.pdf

16

N5101-90001