Tgr100 User Manual v12 Astel Controls

Download as pdf or txt
Download as pdf or txt
You are on page 1of 28

TGR 100

GSM REMOTE CONTROL UNIT


OPERATING INSTRUCTIONS v1.2

CONTENTS
Preface............................................................................................................................................... 3
Features ............................................................................................................................................. 3
Precautions ........................................................................................................................................ 3
Controls And Connectors ................................................................................................................... 4
Installation .......................................................................................................................................... 5
DC power supply and Accumulator connection............................................................................ 5
Control connections ..................................................................................................................... 6
Relays connection ................................................................................................................. 6
Digital outputs connection...................................................................................................... 6
Alarm connections ....................................................................................................................... 7
Digital inputs connection........................................................................................................ 7
Analog inputs connection....................................................................................................... 7
Temperature sensors connection .......................................................................................... 8
Other connections........................................................................................................................ 8
Speaker and Microphone connection .................................................................................... 8
Remote keyboard connection ................................................................................................ 8
I2C bus connection................................................................................................................ 9
RS-232 connection ................................................................................................................ 9
Instructions....................................................................................................................................... 10
Login .......................................................................................................................................... 10
Controls ..................................................................................................................................... 10
Relays.................................................................................................................................. 10
Digital outputs...................................................................................................................... 11
Alarms........................................................................................................................................ 12
Digital inputs ........................................................................................................................ 12
Analog inputs....................................................................................................................... 13
Temperature sensors .......................................................................................................... 14
GPS receiver ....................................................................................................................... 15
Other alarm functions................................................................................................................. 17
Alarm set-up .............................................................................................................................. 19
Other functions .......................................................................................................................... 19
DTMF instructions...................................................................................................................... 21
SIM card locations ..................................................................................................................... 22
Technical Specifications................................................................................................................... 24
Optional Accessories........................................................................................................................ 24
Warranty........................................................................................................................................... 26
Declaration Of Conformity ................................................................................................................ 27

_______________________________________________________________________________________________

PREFACE

FEATURES

The TGR 100 is a high-efficient GSM remote


controller specially designed to use as standalone unit or in the combination with other
video surveillance or alarm equipment. Built-in
GSM module with different interfaces enable
simple and easy control and management of
complete electrical and electronic equipment
through GSM mobile phone. Built-in relays
enable remote control of different household
and other devices as are air-conditioning and
heating. The connections with other alarm
equipment and additional sensors enable
remote intruder and fire surveillance and
voltage and temperature measuring and
management.
The control of the unit is possible by the help of
SMS text messages or by the help of tone
(DTMF) dialing. Alarming is possible by
receiving the SMS text messages or by alarm
calls or by the combination of both of them.
Interactive voice responder confirms the
requests during DTMF control or inform about
the kind of alarm when alarm occurs. The unit
enables also speaker and microphone
connection
to
remote
communication.
Programming is possible by the help of SMS
text messages or with PC by the help of RS232 serial interface.
This GSM remote control unit comes in three
versions, Basic, Advance and Reference,
every model is available also with GPS
receiver.

built-in GSM module with SIM interface


built-in GPS module for position
management and alarming***
SMS control (alarms, relays, etc)
DTMF (PSTN, ISDN, GSM) control*
IVR interactive voice responder**
temperature measuring and management*
analog voltage measuring and
management*
alarm sensor management
remote keyboard interface
speaker and microphone interface**
PC remote and local management**
wide range power supply
ABS casing
accumulator connection

PRECAUTIONS

The remote control unit has to be installed


and used in accordance with the
instructions of this manual only.
The power supply has to be disconnected
before installation.
Avoid using the remote control unit under
the presence of appliances generating
strong magnetic fields like radar, wheather
station and in places subject to direct
sunlight.
Do turn power off immediately and refer
servicing to qualified service personnel if
the remote control unit does not operate
normally
following
the
operating
instructions.

CONTROLS AND CONNECTORS

(9) RS-232**
Terminal block to connect RS-232 control
equipment.

(1) DIGITAL IN
Terminal block to connect 8 different sensors.
(2) OPEN C.*
Terminal block to connect 4 different relays or
other control units.

(10) SP MIC**
Terminal block to
Microphone.

(3) RELAY*
Terminal block to connect 4 different devices.

connect

Speaker

and

(11) REMOTE**
Terminal block to connect external keyboard.

(4) DC - ACCU
Terminal block to connect Accumulator and DC
power supply.

(12) ANALOG IN*


Terminal block to connect 4 different voltage
sources.

(5) GPS antenna connector***


SMA connector to connect GPS antenna.

(13) I2C**
Terminal block
equipment.

(6) Status LED


LED to show the status, LED blinks in normal
operation.

to

connect

I2C

control

(14) SENSOR*
Terminal block to connect 3 temperature or
other sensors.

(7) Alarm LED


LED to show the alarm status, lights when
alarm occurs.

(15) GSM module LED


LED to show the GSM module status, lights in
normal operation..

(8) GSM antenna connector


SMA connector to connect GSM antenna.

INSTALLATION
All the diagrams in this manual show the installation of the GSM Remote Control Unit, model
TGR 100G Reference.
Note:
The main DC power supply has to be switched off before installation.
Also refer to the instruction manual of the equipment to be connected.
The total power consumption of all sensors, relays and other devices supplied from the
unit has not exceed 500mA.
Avoid the installation in extremely hot and cold places and near appliances generating strong
magnetic fields. The installation have to be realize by a qualified personel.
Note:
The GSM and GPS antennas have to be connected before the unit is switched-on.
The SIM card have to be inserted before the unit is switched-on. The SIM location 3
(password) has to be empty. The PIN code request have to be disabled.
DC power supply and Accumulator connection
The power supply have to be connected to the DC terminal block connector with right polarity and
protected with a fuse (not included). The power supply voltage have to be from 12 - 30VDC. The
back-up accumulator have to be connected to the ACCU terminal block connector with right polarity
and also protected with a fuse (not included).
Note:
The declared accumulator voltage have to be the same as the DC power supply voltage.

F0.5A

F0.5A

Control connections
Relays connection*
The relay control outputs are suitable to control four different household and other devices as are airconditioning and heating, connected directly or through external relays. First two relays have NO and
NC contacts, other two relays have only NO contacts.
Note:
The total DC curent consumption of connected equipment to each relay must not exceed
1A when the equipment are controlled directly from the unit. The maximum voltage
connected to the relays must not exceed 30V.

F1
P

P
P

DC
N

Digital outputs connection*


The digital outputs are suitable to control four different household and other devices connected
through external relays.
Note:
The total DC curent consumption of each connected relay must not exceed 100mA.

GND
F1
P
P
N


+
DC

+
DC

Alarm connections
Digital inputs connection
The digital inputs are suitable to connect eight different sensors like IR intruder sensors, smoke
sensors, water inlet sensors (floating switches) with NO or NC contacts. The sensors can be supplied
directly from the unit and connected to one of +ACCU terminal block.
Note:
The total power consumption of each sensor supplied from the unit must not exceed
100mA.

S1 S3 S5 S7
S2 S4 S6 S8

Analog inputs connection*


The analog inputs are suitable to connect four different voltage sources and to measure their
voltages.
Note:
Only the DC voltage can be connected to the analog inputs.
The maximum DC voltage connected to each input must not exceed 30Vdc.

Temperature sensors connection*


The unit is designed to connect maximum three temperature sensors to measure the temperature in
different places.
Note:
Only the specified sensors can be connected to the temperature sensors inputs.

T1

T2

T3

Other connections
Speaker and Microphone connection**
The unit is designed to connect the microphone which enables to listen the voice and low-power
speaker for communication and notification.
Note:
Only the specified speaker and microphone can be connected to the unit.

Remote keyboard connection**


The unit is designed to connect the simple remote keyboard which enables operating with the unit to
enable and disable the alarming and other functions.
Note:
Only the specified remote keyboard can be connected to the unit.

KEYBOARD
I2C bus connection**
The unit is designed to connect also the devices using the I2C protocols.
Note:
Only the devices using I2C protocol can be connected to the I2C interface.

I2C bus
device

RS-232 connection**
The unit is designed to connect also the devices using the RS-232 serial interface control like
personal computer or other devices.
Note:
Only the devices using RS-232 serial interface can be connected to the RS-232 port.

PC

INSTRUCTIONS
Login
The default setting of password is 1234.
To send the password
PWDxxxx

x=1..9

PWD1234 (if the password is 1234)


(PWD instruction should be uppercase, other instructions uppercase or lowercase)
PWD1234_instr1_instr2_instr3
(first should be sent the password then space and then instructions)
To change the password
NPWxxxx

x=1..9

NPW2222 (if the new password is 2222)

Controls
Relays*
To receive a status of relays:
REL
Received SMS:
NAME
REL1:REL1:12.10
REL2:REL2:ON
REL3:REL3:OFF
REL4:REL4:REM
To switch-on the relay:
RELxON

x=1..4

REL1ON (to switch-on the relay 1)


To switch-off the relay:
RELxOFF

x=1..4

REL1OFF (to switch-off the relay 1)


To switch-on the relay for selected time duration:
RELxONhh.mm.ss x=1..4
hh=0..24
mm=0..60
ss=0..59
REL1ON12.10.00 (to switch-on the relay for 12 hours, 10 minutes)
10

To switch-on the relay when alarm occurs:


RELxALMhh.mm.ss x=1..4
hh=0..24
mm=0..59
ss=0..59
REL2ALM00.10.30 (switching-on the relay 2 for 10 minutes, 30 seconds)
To confirm the alarm by switching-off the relay
RELxALM

x=1..4

REL2ALM (temporary switching-off the relay 2)


To switch-on audio or other indication when alarming is enabled/disabled:
RELxREM

x=1..4

REL4REM (to switch-on audio or other indication on the relay 4)


Digital outputs*
To receive a status of open-collector outputs:
OCE
Received SMS:
NAME
OCE1:OCE1:12.10.00
OCE2:OCE2:ON
OCE3:OCE3:OFF
OCE4:OCE4:REM
To switch-on the open-collector output
OCExON

x=1..4

OCE1ON (to switch-on the open-collector output 1)


To switch-off the open-collector output
OCExOFF

x=1..4

OCE1OFF (to switch-off the open-collector output 1)


To switch-on the open-collector for selected time duration:
OCExONhh.mm

x=1..4
hh=0..24
mm=0..60
ss=0..59

OCE1ON12.10.00 (to switch-on the open-collector 1 for 12 hours, 10 minutes)

11

To switch-on audio indication when alarming is enabled/disabled:


OCExREM

x=1..4

OCE4REM (to switch-on audio indication on the open-collector output 4)

Alarms
Digital inputs
To receive alarm status on digital inputs:
ADS
Received SMS:
NAME
ALM:
D1:IN1:OFF
D2:IN2:OFF
D3:IN3:ON
D4:IN4:OFF
D5:IN5:OFF
D6:IN6:OFF
D7:IN7:REM
D8:IN8:REM
(when switching-on/off of alarming is enabled by the help of the digital inputs D7 in D8)
To enable alarms on digital inputs:
ADSxxxxxxxx

x=1 or 0

ADS00100000 (to enable alarm on digital input 3)


To receive alarm triggering on digital inputs:
ADT
Received SMS:
NAME
TRG:
D1:HIGH
D2:HIGH
D3:LOW
D4:LOW
D5:LOW
D6:LOW
D7:REM
D8:REM
(when switching-on/off of alarming is enabled by the help of the digital inputs D7 in D8)

12

To define alarm triggering on digital inputs:


ADTxxxxxxxx

x=1 or 0

1- to activate the alarm when the input is high open contact


0- to activate the alarm when the input is low close contact
ADT11100000 (1.,2. high inputs, 3, 4.,5.,6.,7.,8., - low inputs)
Alarming:
Received SMS:
NAME
ALARM:IN3:LOW
Analog inputs*
To receive alarm status on analog inputs:
AAS
Received SMS:
NAME
ALM:
A1:V1:OFF
A2:V2:OFF
A3:V3:OFF
A4:V4:ON
A5:DC:ON
A6:ACCU:ON
To enable alarms on analog inputs:
AASxxxx

x=1 or 0

AAS000111 (to enable alarm on analog input 4,5,6)


To receive alarm triggering on analog inputs:
AAT
Received SMS:
NAME
TRG:
A1:Low:10.2V
High:20.2V
A2:Low:0.0V
High:30.0V
A3:Low:0.0V
High:30.0V
A4:Low:11.0V
High:30.0V
A5:Low:10.0V
High:14.0V
A6:Low:10.0V
High:14.0V
13

To define alarm triggering on analog inputs:


AATxsnn.n.snn.n

x=1..6
s=L or H
nn.n=number with decimal point, max. 30.0

AAT1L10.2H20.2
(to activate the alarm when input voltage is lower than 10.2V and higher than 20.2V)
Alarming:
Received SMS:
NAME
ALARM:V4:10.5V
ALARM:DC:9.5V
ALARM:ACCU:9.5V
Temperature sensors*
To receive alarm status on temperature sensors:
ATS
Received SMS:
NAME
ALM:
T1:TEMP1:OFF
T2:TEMP2:OFF
T3:TEMP3:ON
To enable alarms on temperature sensors:
ATSxxxx

x=1..3

ATS001 (to enable alarm on sensor 3)


To receive alarm triggering on temperature sensors:
ATT
Received SMS:
NAME
TRG:
T1:Low:20.0C
High:30.0C
T2:Low:-50.0C
High:120.0C
T3:Low:2.0C
High:38.0C

14

To define alarm triggering on temperature sensors:


ATTxsnn.n.snn.n

x=1..3
s=L or H
nn.n= number with decimal point

ATT1L10.5H20.5
(to activate the alarm when temperature on sensor 1 is lower than 10.5C and higher than 20.5C)
Alarming:
Received SMS:
NAME
ALARM:TEMP3:38.5C
GPS receiver***
To receive alarm status on pre-defined positions:
AGS
Received SMS:
NAME
ALM:
P1:POS1:ON
P2:POS2:OFF
P3:POS3:OFF
P4:POS4:ON
To enable alarms on pre-defined positions:
AGSxxxx

x=1 or 0

AGS1001 (to enable GPS alarm on position 1 and 4)


To receive alarm triggering on pre-defined positions:
AGT
Received SMS:
NAME
TRG:
P1:Out:0.25km
P2:In:0.20km
P3:In:0.20km
P4:In:0.30km

15

To define distances and mode for alarm triggering:


AGTxsn.nnu

x=1..4
s=I or O (IN or OUT)
n.nn=number, max. 9.99
u=k or n or m (km, nm, m)

AGT1O0.25k
(to activate the alarm when the distance from position 1 is longer than 0.25 km)
AGT4I0.30k
(to activate the alarm when the distance to position 4 is shorter than 0.30 km)
To receive pre-defined positions for alarm triggering:
AGC
Received SMS:
NAME
POS:
P1:Lat:45,45.281N
Lon:013,49.892E
P2:Lat:0
Lon:0
P3:Lat:0
Lon:0
P4:Lat:45,48.390N
Lon:013,48.300E
To define positions for alarm triggering:
AGCxann,nn.nnnbnnn,nn.nnn

x=1..4
a=n,s
b=e,w
n=1-9

AGC1n45,45.281e013,49.892 (position 1 is 45,45.281N in 013,49.892E)


To avtomatically insert the alarm position by the help of momentary position:
AGMx

x=1..4

AGM1 (to avtomatically insert momentary position to alarm position P1)


Alarming:
Received SMS:
NAME
ALARM:GPS.POS1:OUT

16

GPS receiver status:


Received SMS:
NAME
GPS:UNLOCKED (when at least one AGS is ON and GPS signal is unlocked)
Received SMS:
NAME
GPS:LOCKED (when at least one AGS is ON and GPS signal is repeatedly locked)

Other alarm functions


To generally switch-on the alarming:
ALMON
(the delay time of alarming is reset)
To generally switch-off the alarming:
ALMOFF
To generally switch-on the alarming with delay:
ALMONhh.mm.ss

hh=0..24
mm=0..59
ss=0..59

ALMON00.02.30 (the delay of alarming for 2 minutes, 30 seconds)


(when the alarming is switched-on/off by the remote control the delay time remains the same)
To enable the switching-on/off of alarming by the remote control on the inputs KEY1 and KEY2:**
REMKON
REMKON (switching-on/off of alarming is enabled)
To enable the switching-on/off of alarming by the remote control on the inputs D7and D8:
REMDON
REMDON (switching-on/off of alarming is enabled)
To disable the switching-on/off of alarming by the remote control on the inputs KEY1 and KEY2:**
REMKOFF
REMKOFF (switching-on/off of alarming is disabled)
To disable the switching-on/off of alarming by the remote control on the inputs D7and D8:
REMDOFF
REMDOFF (switching-on/off of alarming is disabled)
17

To check the remote control status:


REM
Received SMS:
NAME
REMOTE ALARMS:
KEY:ON (switching-on/off of alarming is enabled on the inputs KEY1 in KEY2)
DIG:OFF (switching-on/off of alarming is disabled by the help of the digital inputs D7 in D8)
To receive alarm status:
ALM
Received SMS:
NAME
ALARMS:ON (the alarming is switched-on)
Received SMS:
NAME
ALARMS:ON.DEL:00.02.30
(the alarming is switched-on with delay of 2 minutes and 30 seconds)
To check alarmed functions:
ALMCHK
Received SMS:
NAME
ALARM:IN7:LOW
Received SMS:*
NAME
ALARM:V4:10.5V
Received SMS:*
NAME
ALARM:DC:9.5V
Received SMS:*
NAME
ALARM:ACCU:9.5V
Received SMS:*
NAME
ALARM:TEMP3:38.5C
Received SMS:***
NAME
ALARM:GPS.POS1:OUT

18

Alarm set-up
To set-up the alarming of the unit:
Write the GSM numbers for receiving SMS to the SIM card location from 43 to 52.
Write the phone numbers for calling to the SIM card location from 90 to 99.**
Write the location of the first GSM number for receiving SMS to the SIM card location 8.
Write the location of the last GSM number for receiving SMS to the SIM card location 9.
Write the location of the first phone number for calling to the SIM card location 1.**
Write the location of the last phone number for calling to the SIM card location 2.**
Set all the alarms status and triggering by instructions ADS, ADT, AAS*, AAT*, ATS*, ATT* and
on the models with GPS receiver also by the AGS***, AGT***, AGC*** or AGMx***.
When the remote control is used set the switching-on/off of alarming by instructions REMKON* or
REMDON and audio or other indication by instructions RELxREM* or OCExREM*.
When the relays are used with alarming set the relay time by instruction RELxALM*.
Switch-on the alarming by instructions ALMON or ALMONhh.mm.ss or with remote control.

Other functions
To receive the status of digital inputs:
DIG
Received SMS:
NAME
D1:IN1:LOW
D2:IN2:LOW
D3:IN3:LOW
D4:IN4:HIGH
D5:IN5:HIGH
D6:IN6:HIGH
D7:IN7:LOW
D8:IN8:HIGH
To receive the voltage on the analog inputs:
ANG*
Received SMS:
NAME
A1:V1:11.0V
A2:V2:5.8V
A3:V3:5.9V
A4:V4:10.5V
A5:DC:9.5V
A6:ACCU:9.5V
To receive the temperature on the temperature sensors:
TMP*
Received SMS:
NAME
T1:TEMP1:23.5C
T2:TEMP2:23.0C
T3:TEMP3:22.0C
19

To receive the momentary GPS position:


GPS***
Received SMS:
NAME
Lat:45,45.281N
Lon:013,49.892E
Altitude: 288.3m
To receive status of the digital inputs, the voltage on the analog inputs, the temperature on the
temperature sensors and momentary GPS position:
SMS*
To receive GSM operator, signal, power supply voltage, accumulator voltage, GPS receiver status
and software version:
MON
To define the GSM tel. number to which the SMS answer of requested instruction would be sent:
FWDx_instr

x=GSM tel. number

FWD0038641123456_rel (to send the relay status on GSM tel. number 0038641123456)
To write the number to the location on the SIM card
PBWs&x&

s=location on the SIM card


x=number

PBW55&0038641123456& (to write the number 0038641123456 on the location 55)


To write the name to the location on the SIM card
PBWs&&n

s=location on the SIM card


n=name

PBW55&&kiko (to write the name KIKO on the location 55)


To write the name and number to the location on the SIM card
PBWs&x&n

s=location on the SIM card


x=number
n=name

PBW55&0038641123456&kiko
(to write the number 0038641123456 and name KIKO on the location 55)
To delete the contents on the location on the SIM card
PBWs&&

s=location on the SIM card

PBW55&& (to delete the contents on the location 55)


20

To receive the contents on the location on the SIM card


PBRs

s=location on the SIM card

PBR55 (to receive the contents on the location 55)

DTMF instructions*
#1234#

password

#81x#
#80x#

to switch-on the relays


to switch-off the relays

#71x#
#70x#

to switch-on open-collector outputs


to switch-off open-collector outputs

#98#
#97#
#60#

to generally enable all alarms:


to generally disable all alarms:
to check alarmed functions

#95#
#96#

to switch-on a microphone
to switch-on a microphone and speaker

#91#

to receive the status (like SMS instruction)

21

SIM card locations


s&x&n

s=location on the SIM card


x=number
n=name

Location (s):
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49

&location of the first call number& &0& - no call**


&location of the last call number&**
password (4 digits)
reserved
reserved
reserved
reserved
&location of the first SMS number&
&0& - no SMS
&location of the last SMS number&
reserved
&&IN1
&&IN2
&&IN3
&&IN4
&&IN5
&&IN6
&&IN7
&&IN8
&&REL1*
&&REL2*
&&REL3*
&&REL4*
&&OC1*
&&OC2*
&&OC3*
&&OC4*
&&TEMP1*
&&TEMP2*
&&TEMP3*
&&NAME
reserved
reserved
reserved
reserved
reserved
&&V1*
&&V2*
&&V3*
&&V4*
&&ACCU
&&DC
reserved
&SMS number 1&
&SMS number 2&
&SMS number 3&
&SMS number 4&
&SMS number 5&
&SMS number 6&
&SMS number 7&
22

50
51
52
53
54
55
56
57
58
59
60
61
...
90
91
92
93
94
95
96
97
98
99

&SMS number 8&


&SMS number 9&
&SMS number 10&
reserved
reserved
&&POS1***
reserved
&&POS2***
reserved
&&POS3***
reserved
&&POS4***
reserved
&call number 1&**
&call number 2&**
&call number 3&**
&call number 4&**
&call number 5&**
&call number 6&**
&call number 7&**
&call number 8&**
&call number 9&**
&call number 10&**

23

TECHNICAL SPECIFICATIONS
Power supply
Accumulator (option)
Relays*
Digital outputs*
Digital inputs
Analog inputs*
Temperature sensor interface*
Keyboard interface**
Audio interface**
I2C interface**
PC serial interface**
Casing
Protection
Dimensions
Weight

12-30 Vdc
1, the same voltage as power supply
2 x NO/COM, 2 x NO/NC/COM
4, open-collector
8, NO, TTL, 12V
4 (6), 0-30 Vdc (10 bit, 2LSB)
3, I2C interface
1
1, speaker, microphone
1
1, RS-232
ABS
IP-65 (VDE)
210x165x55mm
0.7 kg

GSM module
Quad-band
SIM card interface
Antenna connector

E-GSM-900, GSM-850, DCS-1800, PCS-1900


3V
SMA

GPS module***
GPS receiver
Sensitivity
Antenna connector
Antenna power supply

20- channel parallel GPS receiver


-159 dBW min.
SMA
3-5 Vdc

(*) only for ADVANCE and REFERENCE models


(**) only for REFERENCE model
(***) only for TGR 100G models with GPS receiver

OPTIONAL ACCESSORIES

Temperature sensor TT 01
Temperature sensor TT 02
IR intruder sensor TIR 01
IR intruder sensor TIR 02
IR intruder sensor TIR 03W
Smoke sensor TF 01
Smoke sensor TF 02W
Water inlet sensor TW 01
Magnetic Switch TM 02
Magnetic Switch TM 03W

GSM antenna TAGM 01


GSM antenna TAGM 03
GPS antenna TAGP 02
Accumulator TAC 12
Keyboard TKB 120
Transmitter TRT 04W
Receiver TRR 04W
Keyfob Transmitter TRC 04W

Design and specifications subject to change without notice.

24

WARRANTY
1. The equipment manufactured by ASTEL d.o.o. is warranted to be free from defects in workmaship
and materials under normal use and service.
2. This Warranty is in effect for of two years from the date of purchase by the user. Proof of purchase
must be included, to establish that it is inside the warranty period.
3. This Warranty is transferrable and covers the product for the specified time period.
4. In case any part od the equipment proves to be defective, other than those parts excluded in
paragraph 5 below, the owner should do the following:
(a) prepare a detailed written statement of the nature and circumstances of the defect, to the best
of the Owners knowledge, including the date of purchase, the place of purchase, the name and
adress of the installer, and the Purchasers name, adress and telephone number;
(b) the Owner should return the defective part or unit along with the statement referenced in the
preceding paragraph to the warrantor, ASTEL d.o.o., or an authorized distributor,
postage/shipping prepaid and at the expense of the Purchaser;
(c) if upon the Warrantors or authorized distributors examination, the defect is determined to
result from defective material or workmanship, the equipment will be repaired or replaced at the
Warrantors option without charge, and returned to the Purchaser at the Warrantors expense;
(d) no refund of the purchase price will be granted to the Purchaser, unless the Warrantor is
unable to remedy the defect after having a reasonable number of opportunities to do so. Prior
to refund of the purchase price, Purchaser must submit a statement in writing from a
professional boating equipment supplier that the installation instructions of the Operating
Instructions manual have been complied with and that the defect remains;
(e) warranty service shall be performed only by the Warrantor, or an authorized distributor, and
any attempt to remedy the defect by anyone else shall render this warranty void.
5. There shall be no warranty for defects or damages coused by faulty installation or hook-up, abuse
or misuse of the equipment including exposure to excessive heat, salt or fresh water spray, or
water immersion except for equipment spacially designed as waterproof.
6. There shall be no responsibility or liability whatsoever on the part of the Warrantor or its
employees and representatives for injury to any person or persons, or damage to property, loss of
income or profit, or any other consequential or resulting damage or cost which may be claimed to
have been incurred through the use or sale of the equipment, including any possible failure or
malfunction of the equipment, or part thereof.
7. The Warrantor assumes no liability for incidental or consequential damages of any kind including
damages arising from collision with other vessels or objects.

25

DECLARATION OF CONFORMITY
according to IEC Guide 22 and EN 45014

Manufacturer's Name:

ASTEL, Podjetje za projektiranje, proizvodnjo in


trgovino, d.o.o.

Manufacturer's Address:

Dutovlje 138
6221 Dutovlje
Slovenija

declares that the products


Item, Product Name and Model Number: 1. GSM Remote Control Unit TGR 100 series

conform to the following Product Specifications:


Radio Spectrum:

EN 300 511 and 3GPP 51.010-1

EMC:

EN 301 489-1 and EN 301 489-7

Electrical Safety:

EN 60950

Supplementary Information:
The products herewith comply with the requirements of the following Directives and carry the CEmarking accordingly:
- the R&TTE Directive 1999/5/EC
- the Low Voltage Directive 73/23/EEC
- the EMC Directive 89/336/EEC
ASTEL d.o.o.
Dutovlje 138
6221 Dutovlje
Slovenija
11th May, 2005

26

DECLARATION OF CONFORMITY
according to IEC Guide 22 and EN 45014

Manufacturer's Name:

ASTEL, Podjetje za projektiranje, proizvodnjo in


trgovino, d.o.o.

Manufacturer's Address:

Dutovlje 138
6221 Dutovlje
Slovenija

declares that the products


Item, Product Name and Model Number: 1. GSM Remote Control Unit TGR 100G series

conform to the following Product Specifications:


Radio Spectrum:

EN 300 511 and 3GPP 51.010-1

EMC:

EN 301 489-1 and EN 301 489-7


EN 50082-1 and EN 61000-6-1

Electrical Safety:

EN 60950

Supplementary Information:
The products herewith comply with the requirements of the following Directives and carry the CEmarking accordingly:
- the R&TTE Directive 1999/5/EC
- the Low Voltage Directive 73/23/EEC
- the EMC Directive 89/336/EEC
ASTEL d.o.o.
Dutovlje 138
6221 Dutovlje
Slovenija
11th May, 2005

27

ASTEL d.o.o., Dutovlje 138, 6221 Dutovlje, Slovenia


Tel: +386 5 7310771, +386 5 7310772
Fax:+386 5 7310789
E-mail: [email protected]
Web: www.astel-controls.com
28

You might also like