Equipo 1. A distillation column separating ethanol from water is shown.

Pressure is 1 kg/cm2. Instead of having a reboiler, steam (pure water


vapor) is injected directly into the bottom of the column to provide heat.
The injected steam is a saturated vapor. The feed is 30 wt % ethanol and
is at 20 C. Feed flow rate is 100 kg/min. Reflux is a saturated liquid. We
desire a distillate concentration of 60 wt % ethanol and a bottoms
product that is 5 wt % ethanol. The steam is input at 100 kg/min. What is
the external reflux ratio, L/D?

Equipo 2. A distillation column separating ethanol from water is shown.


Pressure is 1 kg/cm2. Instead of having a condenser, a stream of pure
liquid ethanol is added directly to the column to serve as the reflux. This
stream is a saturated liquid. The feed is 40 wt % ethanol and is at 20
C. Feed flow rate is 2000 kg/h. We desire a distillate concentration of 80
wt % ethanol and a bottoms composition of 5 wt % ethanol. A total
reboiler is used, and the boilup is a saturated vapor. The cooling stream
is input at C = 1000 kg/h. Find the external boilup rate. Note: Set up the
equations, solve in equation form for including explicit equations for all
required terms, read off all required enthalpies from the enthalpy
composition diagram, and then calculate
a numerical answer.
Equipo 3. A distillation column is separating ethanol from water at a
pressure of 1 kg/cm2. A two-phase feed of 20 wt% ethanol at 93C is
input at 100 kg/min. The column has a total condenser and a partial
reboiler. The distillate composition is 90 wt % ethanol. Distillate and
reflux are at 20C. Bottoms composition is 1 wt % ethanol. Reflux ratio is
L0/D = 3. A liquid side stream is withdrawn above the feed stage. Side
stream is 70 wt % ethanol, and side stream flow rate is 10 kg/min. Find
D, B, Qc, and QR.
Equipo 4. A continuous, steady-state distillation column is fed a mixture
that is 70 mol% n-pentane and 30 mol% n-hexane. Feed rate is 1000
kmol/h. Feed is at 35C. Column is at 101.3 kPa. The vapor distillate
product is 99.9 mol% n-pentane and the bottoms product is 99.9 mol%
n-hexane. The system has a partial condenser (thus the distillate product

is a saturated vapor) and operates at an external reflux ratio of L/D =


2.8. The reboiler is a partial reboiler. Find D, B, Qc & Q R. Use DePriester
chart to determine boiling points.
Equipo 5. A distillation column is separating 500 kmol/h of a mixture that
is 76 mol% methanol and 24 mol% water. The bottoms product contains
0.00002 mole fraction methanol, and the distillate is 0.9999 mol%
methanol. The boilup ratio = 1.5. Estimate the reboiler heat duty QR.
Equipo 6. A mixture of oxygen and nitrogen is to be distilled at low
temperature. The feed rate is 25,000 kmol/h and is 21 mol% oxygen and
79 mol% nitrogen. An ordinary column will be used. Column pressure is 1
atm. The feed is a superheated vapor at 100 K. We desire a bottoms
composition of 99.6 mol% oxygen and a distillate that is 99.7 mol%
nitrogen. Reflux ratio is L0/D = 4, and reflux is returned as a saturated
liquid. Find D, B, QR, and Qc.

Equipo 7. A mixture of water and ammonia is to be distilled in an


ordinary distillation system at a pressure of 6 kg/cm2. The feed is 30 wt
% ammonia and is at 20 C. We desire a distillate product that is 98 wt %
ammonia and a 95% recovery of the ammonia in the distillate. The
external reflux ratio is L0/D = 2.0. Reflux is returned at 20 C. Find D,
B, xB, QR, and Qc per mole of feed.