AQ 09 12 FAN Service Manual PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 88

SPLIT-TYPE AIR CONDITIONER

Basic : AQ12FA
Model : AQ12FA
AQ09FA
AS12FAXFA
AS12FBAXAP
Model Code : AQ12FAN/AQ12FAX
AQ09FAN/AQ09FAX
AS12FANXFA/AS12FAXXFA
AS12FBANXAP/AS12FBAXXAP

SERVICE

Manual

AIR CONDITIONER

AQ12FAN/AQ12FANSER/AS12FANXFA/AS12FBANXAP

THE FEATURE OF PRODUCT

Good Morning Mode

Catechin Filter

Silver Nano Evaporator

Deodorizing Filter

Anti-Bacterial Cross Fan

AQ12FAX/AQ12FAXSER/AS12FAXXFA/AS12FBAXXAP

For more information, Please access to our service web site(http://itself.sec.samsung.co.kr)

Operating Instructions and Installation

Contents
11. Precautions ................................................................................................................................................... 1-1
1-1 Installing the air conditioner ...................................................................................................................

1-1

1-2 Power supply and circuit breaker ..........................................................................................................

1-1

1-3 During operation

........................................................................................................................................

1-1

1-4 Disposing of the unit .................................................................................................................................

1-2

1-5 Others .............................................................................................................................................................

1-2

12. Product Specifications ........................................................................................................................ 2-1


2-1 The Feature of Product

.............................................................................................................................

2-1

2-2 Product Specifications

..............................................................................................................................

2-2

2-3 The Comparative Specifications of Product .......................................................................................

2-4

2-4 Accessory and Option Specifications ...................................................................................................

2-5

13. Alignment and Adjustments ......................................................................................................... 3-1


3-1 Test Mode ......................................................................................................................................................

3-1

3-2 Error Mode and Check Method ..............................................................................................................

3-3

3-3 Setting Option Setup Method ................................................................................................................

3-7

14. Disassembly and Reassembly ...................................................................................................... 4-1


4-1 Indoor Unit ....................................................................................................................................................

4-1

4-2 Outdoor Unit

4-4

...............................................................................................................................................

15. Exploded Views and Parts List ..................................................................................................... 5-1


5-1 Indoor Unit ....................................................................................................................................................

5-1

5-2 Outdoor Unit ................................................................................................................................................

5-5

5-3 Assy Control In ............................................................................................................................................

5-9

16. Electrical Parts List


17. Wiring Diagram

.................................................................................................................................

6-1

........................................................................................................................................

7-1

18. Schematic Diagram

...............................................................................................................................

8-1

19. Circuit Descriptions ............................................................................................................................... 9-1


9-1 PCB Circuit Descriptions ...........................................................................................................................

9-1

9-2 Refrigerating Cycle Diagram ...................................................................................................................

9-2

Samsung Electronics

Operating Instructions and Installation

Contents
10. PCB Diagram ................................................................................................................................................ 10-1
11. Operating Instructions ....................................................................................................................... 11-1
11-1 Name of Each Part .................................................................................................................................... 11-1
11-2 Main Function

...........................................................................................................................................

11-3

11-3 Wireless Remote Control-Buttons and Display ............................................................................... 11-5

12. Troubleshooting ...................................................................................................................................... 12-1


12-1 Basic Breakdown Diagnosis Items ....................................................................................................... 12-1
12-2 Trouble check in the initial status......................................................................................................... 12-2
12-3 Breakdown diagnosis by symptoms ................................................................................................... 12-3
12-4 PCB Inspection Method .......................................................................................................................... 12-10
12-5 Main Part Inspection Method................................................................................................................ 12-12

13. Block Diagram ............................................................................................................................................ 13-1


14. Reference Sheet ........................................................................................................................................ 14-1
14-1 Index for Model Name ............................................................................................................................ 14-1
14-2 Refrigerant Pressure during the Charging
14-3 Pressure & Capacity mark

.......................................................................................

14-2

......................................................................................................................

14-2

14-4 Q & A for Non-trouble ............................................................................................................................. 14-3


14-5 Cleaning/Filter Change ........................................................................................................................... 14-6
14-6 Installation .................................................................................................................................................. 14-8
14-7 Installation Diagram of Indoor Unit and Outdoor Unit ................................................................ 14-9

Samsung Electronics

2. Product Specifications
2-1 The Feature of Product
Good Morning Mode

Catechin Filter
Catechin, extracted from the green tea, is contained in the filter and deactivates captured bacteria and unpleasant odors.

Silver Nano Evaporator

Deodorizing Filter
Activated carbon is incorporated in the filter, efficiently absorbing cigarette smoke, pet odors, and other unpleasant smells, replacing
them with clean, refreshing air.

Anti-Bacterial Cross Fan

Samsung Electronics

2-1

2-2 Product Specifications


Model
Item

AQ12FA
INDOOR UNIT

Type
Cooling/Heating(ISO)
COOLING/HEATING(SASO)
Dehumidifying
Perfor- Air volume
mance
Noise

EER

AS12FAXFA

OUTDOOR UNIT

INDOOR UNIT

OUTDOOR UNIT

WALL-MOUNTED

WALL-MOUNTED

KW

3.5/3.8

3.5

BTU/h

KCAL

l/h

1.2

1.2

Cooling

m3/min(H/
M/L)

10.2/8.3/6.1

17

10.2/8.3/6.1

17

Cooling

Db(H/L)

41

54

41

54

COOLING/HEATING(ISO)
COOLING/HEATING(SASO)

POWER
POWER
CONSUMPTION

COOLING/HEATING(ISO)

OPERATING
CURRENT

COOLING/HEATING(ISO)

COOLING/HEATING(SASO)

COOLING/HEATING(SASO)

W/W

2.82/3.22

2.73

BTU/WH

BTU/WH

PH-V-HZ

1-220/240-50

1-220/240-50

1240/1180

1280

6.2/5.3

5.8

Power POWER FACTOR COOLING

86.96/96.80

95.95

STARTING CURRENT

21

21

5.5

5.5

25

25

LENGTH
POWER CORD

NUMBER OF CORE WIRRE


CAPACITY

mm

Outer Dimension WxHxD


Weight(Net)
Refrigerant

825285189

660475242

Kg

8.4

30

8.4

26

mmxL(m)

6.357.5

6.357.5

Gas

mmxL(m)

12.77.5

12.77.5

DxL(m)

182

182

Rotary G4B129JXAEL

Rotary 44D124DXAEL

induction Moter(PSC)

induction Moter(PSC)

13000

12400

POE(FREOL68ES-T)

SUNISO.4GSD/NOC

Moter

Type
Rated Output

Oil Type
Type
Blower

720548265

inch

Type
Compressor

825285189

Liquid

Drain Hose
Size

Motor

Type
Rated Output

Heat exchanger
Refrigerant Control Unit

Cross-flow

Propeller

Cross-flow

Propeller

Resin/steel

Steel

Resin/steel

Steel

37

58

37

58

2ROW 14STEP

1ROW 20STEP

2ROW 14STEP

1ROW 18STEP

Capillary tube

Capillary tube

Freezer Oil Capacity

cc

360

450

Refrigerant to changer

R410A,920g

R22,700g

INLET

INLET

Protection Device(OLP)
Cooling Test Condition

INDOOR UNIT:DB27C/WB19C OUTDOOR UNIT:DB35C WB 24C

Maximum Operation Condition

INDOOR UNIT:DB32C/WB23C OUTDOOR UNIT:DB43C WB 26C

2-2

Samsung Electronics

Model
Item

AQ12FASER
INDOOR UNIT

Type
Cooling/Heating(ISO)
COOLING/HEATING(SASO)
Dehumidifying
Perfor- Air volume
mance
Noise

EER

AS12FBAXAP

OUTDOOR UNIT

INDOOR UNIT

OUTDOOR UNIT

WALL-MOUNTED

WALL-MOUNTED

KW

3.5/3.8

BTU/h

12000/13000

12000

KCAL

3500

l/h

1.2

1.2

Cooling

m3/min(H/
M/L)

10.2/8.3/6.1

17

10.2/8.3/6.1

25

Cooling

Db(H/L)

41

54

41

54

COOLING/HEATING(ISO)
COOLING/HEATING(SASO)

POWER
POWER
CONSUMPTION

COOLING/HEATING(ISO)

OPERATING
CURRENT

COOLING/HEATING(ISO)

COOLING/HEATING(SASO)

COOLING/HEATING(SASO)

W/W

2.78/3.3

2.7

BTU/WH

9.48/11.30

8.7

BTU/WH

PH-V-HZ

1-220/240-60

1-220-60

1260/1150

1300

5.8/5.3

Power POWER FACTOR COOLING

94.4

98.48

STARTING CURRENT

21

21

5.5

5.5

LENGTH
POWER CORD

NUMBER OF CORE WIRRE


CAPACITY

Outer Dimension WxHxD


Weight(Net)
Refrigerant

825285189

660475242

inch

Kg

8.4

30

8.4

26

mmxL(m)

6.35*5.0

6.35*5.0

Gas

mmxL(m)

12.7*5.0

12.7*5.0

DxL(m)

18*2

18*2

Rotary 44D129MXAEL-DO

Rotary 44B135IXAEL

induction Moter(PSC)

induction Moter(PSC)

12730

13400

Moter

Type
Rated Output

Oil Type

NOC & Suniso-4GSD


Type

Blower

25
720548265

Type
Compressor

25
825285189

Liquid

Drain Hose
Size

A
mm

Motor

Type
Rated Output

Heat exchanger
Refrigerant Control Unit

NOC & Suniso-4GSD

Cross-flow

Propeller

Cross-flow

Propeller

Resin/steel

Steel

Resin/steel

Steel

30

58

30

58

2ROW 14STEP

1ROW 20STEP

2ROW 14STEP

1ROW 18STEP

Capillary tube

Capillary tube

Freezer Oil Capacity

cc

450

360

Refrigerant to changer(R22)

830

600

INLET

INLET

Protection Device(OLP)
Cooling Test Condition

INDOOR UNIT:DB27C/WB19C OUTDOOR UNIT:DB35C WB 24C

Maximum Operation Condition

INDOOR UNIT:DB29C/WB19C OUTDOOR UNIT:DB46C WB 24C

Samsung Electronics

2-3

2-3 The Comparative Specifications of Product


AQ12FA
AQ12FASER

Item

AS12FAXFA
AS12FBAXAP

Indoor Unit

Design

Outdoor Unit

Net Weight
Outer Dimension
(WidthxHeightxDepth)

Indoor Unit
Outdoor Unit

33.8kg

Indoor Unit
Outdoor Unit

Outdoor Unit

Air Purifying System

Indoor Display

Filter

29.0kg
1,080x315x205mm

720x548x265mm

Indoor Unit

Noise

2-4

8.4kg

660x475x242mm
36dB
47dB

47dB
Silver Nano Filter
Catechin Filter
Deodorizing Filter
LED

Samsung Electronics

2-4 Accessory and Option Specifications


2-4-1 Accessories
Item

Descriptions

Code-No.

Q'TY

Installation Plate

DB97-02851B

DB93-03170M
(H/P)

Remark

Remote Control
DB93-03170N
(C/O)

Batteries for Remote Control

DB47-90024A

Owners Manual

Installation Manual

Indoor
Unit

TIONS
OWNER'S INSTRUC
INSTRUCCIONES
MANUAL DE
PER L'USO
ISTRUZIONIINSTRU
ES
MANUAL DE ATION
MANUEL D'UTILISEISUNG
GEBRAUCHSANW
Air ConditionerSplit
Splut-type Room
domstico sistema
ad unit Separate
Aire acondicionado
d'aria per ambienti
Split
Condizionatorede ar condicionado tipo
Aparelho
type spar
Climatiseur de
e
Geteilte raumklimaanlag

TIONS
OWNER'S INSTRUC
INSTRUCCIONES
MANUAL DE
PER L'USO
ISTRUZIONIINSTRU
ES
MANUAL DE ATION
MANUEL D'UTILISEISUNG
GEBRAUCHSANW
Air ConditionerSplit
Splut-type Room
domstico sistema
ad unit Separate
Aire acondicionado
d'aria per ambienti
Split
Condizionatorede ar condicionado tipo
Aparelho
type spar
Climatiseur de
e
Geteilte raumklimaanlag

3-wire Assembly Cable


(18)

5-wire Assembly Cable


(24)

Outdoor
Unit
Drain Plug

DB67-20011A

Rubber Leg

DB73-20134A

Assembly Pipe, 6.35mm

DB62-02672D

1
Accessory
Box

Assembly Pipe, 9.52mm


(09)

Samsung Electronics

DB62-02672G

2-5

Product Specifications

Accessories(cont.)
Item

Descriptions

Code-No.

Q'TY

DB62-02672H

Vinyl Tape, Width 80mm

DB72-00459A

Drain Plug

DB67-20011A

Rubber Leg

DB73-20134A

Cable-Tie

DB65-10088C

Cement Nail

M4x16 Tapping Screws

6002-000215

Drain Hose, length 2m

DB67-00274A

Putty 100g

DB98-10568A

Assembly Pipe, 12.70mm


(12)

2-6

Remark

Accessory
Box

Samsung Electronics

5. Exploded Views and Parts List


5-1 Indoor Unit

1-2

14

1-1

15

10
12

16

11

13

4
2-1

2-2
2-3

3-8

3-6

5-1

3-4
5-4

3-1

3-7
5-2

3-2

5-3

3-5
3-3

5-1

Samsung Electronics

Operating
Exploded
Instructions
Views
and
and
Installation
Parts List

Part List
No.
1

Code No.

Description

Specification

AQ12FA

QTY
SA/SNA
AQ12FASER AS12FAXFA AS12FBAXAP

DB94-00454B ASSY BACK BODY

ASSY

SA

1-1

DB61-01632A BODY BACK

HIPS

SNA

1-2

DB69-00834A CUSHION-BODY BACK

EPS

SNA

DB96-06693D ASSY EVAP-TOTAL

ASSY

SA

SA

SNA

DB96-06693E
2-1

DB63-00850A COVER-BEARING

ABS

2-2

DB96-05153C ASSY TUBE EVAP IN

ASSY

SA

SA

SA

SA

DB96-04852A
2-3

DB96-03054K ASSY TUBE EVAP OUT

ASSY

DB96-04851B
3

DB94-00457H ASSY TRAY DRAIN

ASSY

SA

3-1

DB63-00848A TRAY DRAIN

ABS

SA

3-2

DB61-01635A BLADE-H

HIPS

SA

3-3

DB61-01636A BLADE-V

PP

SA

3-4

DB63-00849A TRAY-STABILIZER

ASB

SNA

3-5

DB69-00839A CUSHION EPS-TRAY RH

EPS

SNA

3-6

DB73-00180A RUBBER-CAP DRAIN

GUM-EPM

SNA

3-7

DB95-20138A ASSY MOTOR-STEPPING

GSP-24RW-046

SA

3-8

DB94-00458B ASSY DRAIN-HOSE

ASSY

SA

DB93-04192N ASSY CONTROL IN

ASSY

SA

DB93-04192E

ASSY

SA

DB93-04192P

ASSY

SA

DB93-04192F

ASSY

SA

DB92-00853A ASSY PANEL FRONT

ASSY

SA

5-1

DB64-00989A PANEL FRONT

HIPS

SA

5-2

DB92-00848A ASSY GRILLE-AIR INLET

ASSY, HIPS

SA

5-3

DB97-02064A ASSY COVER-DISPLAY

HIPS,PC

SA

5-4

DB63-01591A GUARD-AIR FILTER

PP

SA

DB97-02851B ASSY-PLATE HANGER

SGCC, T0.6

SA

DB61-01638A HOLDER-PIPE

HIPS

SA

DB63-00844A COVER TERMINAL

HIPS

SA

DB93-03170M ASSY REMOCON

H/P

SA

DB93-03170N

C/O

SA

10

DB96-03149A ASSY EVAP-SUPPORT RH

HIPS

SA

11

DB31-00219A MOTOR FAN

50/60Hz

SA

12

DB94-00456A ASSY CROSS FAN

AS+GF20%

SA

13

DB97-02075A ASSY BOLT-SPECIAL

SA

14

DB94-00455A ASSY BEARING-RUBBER

SA

15

DB94-40007A ASSY BEARING-MOTOR

SA

Samsung Electronics

5-2

PART LIST
SVC LOC

CODE NO

DESCRIPTION

SPECIFICATIONQ

Q'TY

SA/SNA

A0071

DB94-00454J

ASSY BACK BODY

E,Y,GRAY,R22,LF&RH,EXPORT

SA

A0120

DB94-00455A

ASSY BEARING-RUBBER

SS-PJT,CR,BLK SSEC

SA

A0252

DB96-10256A

ASSY U-BEND

C1220T-0,OD7,T0.41,RING 1.3

SA

A0696

DB93-04192N

ASSY CONTROL IN

C/O,-,9K/12K,-,-,-,IN,-,

SA

A0748

DB90-02167B

ASSY COVER-CONTROL IN

WW1-PJT,SSEC

SA

A0755

DB90-03094A

ASSY COVER-DISPLAY

FORTE,SSEC

SA

A0821

DB94-00456A

ASSY-CROSS FAN

SS-PJ,SSEC

SA

A1008

DB96-06862A

ASSY EVAP-TOTAL

FORTE1-INV,SSEC

SA

A1032

DB96-03149B

ASSY EVAP-SUPPORT RH

SS-PJT,-,HIPS,-,-,-

SA

A1203

DB92-00848F

ASSY GRILLE-AIR INLET

FORTE,SSEC

SA

A1579

DB95-20138A

ASSY MOTOR-STEPPING

GSP-24RW-046,AS-568

SA

A1698

DB92-00853F

ASSY PANEL FRONT

NO,-,NO,WHITE,RIGHT,VAL

SA

A1756

DB93-04181A

ASSY PCB MAIN

WW2-P/J,EXP,MAIN ,SSEC

SA

A1756

DB93-04203A

ASSY PCB MAIN

WW1-P/J,EXP,POWER,SSEC

SA

A1839

DB97-02851B

ASSY-PLATE HANGER

KFR-35GW/WAB,CHINA

SA

A1879

DB93-01549F

ASSY-POWER CORD

MID,E,CB

SA

A1928

DB93-03170M

ASSY REMOCON

WW-PJT(Forte), Exp,ARH-462

SA

A2303

DB94-00457J

ASSY TRAY DRAIN

WHITE,RH,1M,Y,R22,-,EXPO

SA

A2355

DB96-03056A

ASSY TUBE EVAP IN

SS-PJT,SSEC 12K

SA

A2356

DB96-03174A

ASSY TUBE EVAP OUT

SS-PJT,SSEC 9K

SA

B0147

DB61-01635C

BLADE-H

FORTE,HIPS,SC-06106R,650.5*56*22

SA

B0179

DB61-01636A

BLADE-V

SS-P/J,PP,BLK,-,SSEC

SA

C0916

DB39-01174A

CONNECT WIRE-PBA

SS-P/J,-,-,1-PIN,-,BRN,

SA

C1485

DB63-00844D

COVER-TERMINAL

FORTE,ABS,2.5,96.4,123,V0

SA

G0120

DB63-01591A

GUARD-AIR FILTER

WW1,PP,2.0,303.4,371.9,

SA

H0286

DB61-01638B

HOLDER-PIPE

VIVACE1,HIPS,2.5,68.5,153.5,

SA

M0039

DB31-00219A

MOTOR FAN

YDK-016S41408-01,SS-P/J Motor

SA

P0021

DB64-00989E

PANEL FRONT

FORTE,HIPS,2.5,285,822,-,WHI

SA

S0224

DB67-60030A

SPRING-SENSOR

WW2-PJT,SGCC,-,-,-,-,-,T0.

SA

T0125

DB62-02813A

TUBE-CU

-,C1220T-O,0.28,7.0,-,-,Tw0.25 H

705.6

SA

5-2 Outdoor Unit(H/P)

20

14-4

14-2

19
18

14

14-1

16

14-3

10

14-5

9
11

3-2

13

12

7
6

3-1

15

4
17
1

2
5

5-3

Samsung Electronics

Exploded Views and Parts List

Part List

No.

Code No.

Description

Specification

AQ12FA

QTY
SA/SNA
AQ12FASER

DB90-01341A ASSY-CABI FRONT

ASSY

SA

DB63-00847A GUARD FAN

PP

SA

DB90-01332A ASSY CABINET-SIDE LF

ASSY

SA

3-1

DB64-01094A CABINET-SIDE LF

SGCC

SA

3-2

DB64-00992A HANDLE-LF

PP

SA

DB90-01546H ASSY CABINET-SIDE RH

ASSY

SA

DB63-00853A COVER-CONTROL

ABS-V0

SA

DB90-01330B ASSY BASE OUT

ASSY

SA

DB99-00401A ASSY VALVE-BRACKET

SGCC

SA

DB94-00668B ASSY PARTITION

ASSY

SA

DB61-01644A BRACKET-MOTOR

SGCC T1.6

SA

10

DB97-02225A ASSY SUPPORT-PLATE B/M

SGCC

SA

11

DB31-00220A MOTOR FAN

YDK020S62213-03

SA

12

DB67-00397A FAN-PROPELLER

AS+GF20%

SA

13

DB60-30020A SCREW-MACHINE

SA

14

DB93-03914F ASSY CONTROL OUT

SA

SA

ASSY

DB93-04248A
14-1

2301-001375

C-FILM

1.5uF/450VAC

SNA

14-2

2501-001237

C-OIL

35uF/450VAC

SNA

2501-001238

40uF/450VAC

SNA

14-3

DB65-40049E TERMINAL-BLOCK

4P

SNA

14-4

DB61-02184A CASE CONTROL OUT

SGCC

SNA

14-5

DB93-00481K ASSY LEAD WIRE-COMP

SNA

15

G4B129JXAEL ROTARY COMPRESSOR

R410A, 50Hz

SA

44D129MXAEL

R22, 50Hz

SA

DB96-05976B ASSY COND

ASSY

SA

DB96-03861G

ASSY

SA

17

DB62-03859A INSULATION-SOUND

EVA+FELT

SA

18

DB96-03858E ASSY TUBE CAPILLARY

ASSY

SA

DB96-03858G

ASSY

SA

DB96-06726A ASSY VALVE 4WAY

ASSY

SA

DB96-07154A

ASSY

SA

DB61-02891A GUIDE-SCREEN

P.E.H. 100%

SA

16

19

20

Samsung Electronics

5-4

5-3 Outdoor Unit(C/O)

11

11-10

11-9
11-1

11-5
11-3
11-4

11-2

8
4
6
10

14
12

16

17
5-1
15

13

5-2

5-5

Samsung Electronics
5-8

Exploded Views and Parts List

Part List
No.

Code No.

Description

Specification

QTY
SA/SNA
AS12FAXFA AS12FBAXAP

DB90-01875A ASSY BASE-OUT PAINT

ASSY

SA

DB94-00927A ASSY-BRACKET VALVE

PP

SA

DB90-01279C ASSY-BRACKET MOTOR

ASSY

SA

DB94-00431D ASSY PARTITION

ASSY

SA

DB90-02372B ASSY CABINET FRONT

ABS-V0

SA

5-1

DB64-01517A CABINET FRONT

PP

SNA

5-2

DB81-00650A BELL MOUSE

PP

SNA

DB64-01518B CABINET-SIDE

PP

SA

DB63-01428A COVER-CONTROL OUT

PP

SA

DB67-00036A FAN-PROPELLER

ASSY

SA

DB31-00034A MOTOR FAN-OUT

ASS025WTVA

SA

10

DB60-30020A SCREW-MACHINE

SGCC

SA

11

DB93-03879B ASSY CONTROL OUT

YDK020S62213-03

SA

2501-001237

35uF/450VAC

SNA

11-1

C-OIL

2501-001236

30uF/450VAC

SNA

11-2

DB93-00481C ASSY LEAD WIRE

ASSY

SNA

11-3

DB61-01102A HOLDER-CAPACITOR

ABS

SNA

11-4

DB65-40049E TERMINAL-BLOCK

4P

SNA

11-5

2301-001375

1.5uF/450VAC

SNA

11-6

DB61-01196A CASE-CONTROL OUT

PP

SNA

44D124DXAEL ROTARY COMPRESSOR

R22, 50Hz

SA

44B135IXAEL

R22, 60Hz

13

DB72-00720A SPONGE-COMP SIDE

14

DB96-05701B ASSY COND

ASSY

DB96-05701A

ASSY

DB96-06390A ASSY TUBE SUCTION

ASSY

DB96-06390B

ASSY

DB96-06389A ASSY TUBE DISCHARGE

ASSY

DB96-06389B

ASSY

DB96-05608E ASSY TUBE CAPILLARY

ASSY

12

15

16

17

Samsung Electronics

C-FILM

SA
1

SA
1

SA
SA

1
1

SA

SA
SA

SA

SA

5-6

5-4 Ass'y Control In


DB93-04479A
A-TYPE

5-9

B-TYPE

Samsung Electronics

Exploded Views and Parts List

Part List
DB93-04479F
No.

Code No.

1
2
3
4

6002-000231
6501-000123
DA02-10017J
DB32-00020E

TH,+,-,2S,M4,L12,ZPC(YEL),SWRCH18A,DACT-140,-,W3.6,L146,NTR,NYLON66
3M #8915,-,T0.15,W18,L55M,-,103AT,-,-,-20~+100,-,-,-,-,SSEC

1
2
1
1

SA
SNA
SNA
SA

SCREW-TAPPING
CABLE TIE
TAPE ETC-FILAMENT
THERMISTOR-WIRE
ASSY
DB39-01165E CONNECT WIRE

Description

Specification

SNA

6
7
8
9
10

DB61-01980A
DB61-02618B
DB62-03861C
DB63-00851A
DB65-00176D

WW2-P/J,#1015 16 AWG,-,1P,-,BLU,-,175022-1
(AMP),175057-1 (AMP),TP,220V/50Hz,4mm,120mm,-,,TUBE?SSEC
AQT24W6WE,ABS,2.0,-,-,BLACK,FORTE,ABS,2.0,156,257,BLACK,SSEC
NEW-WW1,PEB-2,GREEN,15,20,30,SSEC
SS-PJT,ABS,-,-,-,-,-,NO,SSEC
WW1,JXW,4PIN,4mm,36.4*47,BLK,600V,30A

1
1
1
1
1

SA
SA
SNA
SNA
SNA

1
1
1

SNA
SNA
SC

1
1
2

SA
SA
SA

HOLDER-WIRE CLAMP
CASE CONTROL-IN
SEAL-CONTROL IN
COVER-DRAIN
TERMINAL BLOCKTERMINAL
11 DB68-02809A LABEL BAR CODE
-,-,-,-,W170,L115,-,-,-,FOR PACKING CASE
12 DB91-00309A ASSY-SCREW TAPPING WW-INV,M3*20,PH,+,ZPC(YEL)
13 DB93-01638F ASSY POWER CORD
NO PLUG,EXPORT,250V/20A,2340mm,13mm,N,

QTY SA/SNA

MG630591,WHITE,NO,H05VV-F 3*2.5,WW2-PJT,H05VV-F
3*2.5
14 DB93-04181A ASSY PCB MAIN
WW2-P/J,EXP,MAIN ,SSEC
15 DB93-04203E ASSY PCB MAIN
WW-P/J?H/P?25A,POWER,SSEC
16 DB97-02418A ASSY-SCREW TAPPING SS-P/J,TH,M4*L14

DB93-04479G
No.

Code No.

1
2
3
4

6002-000231
6501-000123
DA02-10017J
DB32-00020E

Description

SCREW-TAPPING
CABLE TIE
TAPE ETC-FILAMENT
THERMISTOR-WIRE
ASSY
DB39-01165E CONNECT WIRE

Specification
TH,+,-,2S,M4,L12,ZPC(YEL),SWRCH18A,DACT-140,-,W3.6,L146,NTR,NYLON66
3M #8915,-,T0.15,W18,L55M,-,103AT,-,-,-20~+100,-,-,-,-,SSEC

WW2-P/J,#1015 16 AWG,-,1P,-,BLU,-,175022-1
(AMP),175057-1 (AMP),TP,220V/50Hz,4mm,120mm,-,,TUBE?SSEC
6 DB61-01980A HOLDER-WIRE CLAMP AQT24W6WE,ABS,2.0,-,-,BLACK,7 DB61-02618B CASE CONTROL-IN
FORTE,ABS,2.0,156,257,BLACK,SSEC
8 DB62-03861C SEAL-CONTROL IN
NEW-WW1,PEB-2,GREEN,15,20,30,SSEC
9 DB63-00851A COVER-DRAIN
SS-PJT,ABS,-,-,-,-,-,NO,SSEC
10 DB65-00061F TERMINAL BLOCK
C/O,2P,N(1),1,2TAB,2SCREW,300V,20A,36.4*24.2,BLACK,N(1),1
11 DB68-02809A LABEL BAR CODE
-,-,-,-,W170,L115,-,-,-,FOR PACKING CASE
12 DB91-00309A ASSY-SCREW TAPPING WW-INV,M3*20,PH,+,ZPC(YEL)
13 DB93-01638F ASSY POWER CORD
NO PLUG,EXPORT,250V/
20A,2340mm,13mm,N,MG630591,WHITE,NO,H05VV-F
3*2.5,WW2-PJT,H05VV-F 3*2.5
14 DB93-04181A ASSY PCB MAIN
WW2-P/J,EXP,MAIN ,SSEC
15 DB93-04203F ASSY PCB MAIN
WW-P/J?C/O?25A,POWER,SSEC
16 DB97-02418A ASSY-SCREW TAPPING SS-P/J,TH,M4*L14

Samsung Electronics

QTY SA/SNA
1
2
1
1

SA
SNA
SNA
SA

SNA

1
1
1
1
1

SA
SA
SNA
SNA
SNA

1
1
1

SNA
SNA
SA

1
1
2

SA
SA
SA

5-10

Exploded Views and Parts List

DB93-04193A

3-26

Samsung Electronics

Exploded Views and Parts List

Part List
DB93-04193C
No.

Code No.

Description

Specification

QTY SA/SNA

6501-000123 CABLE TIE

DACT-140,-,W3.6,L146,NTR,NYLON66

SNA

103AT,-,-,-20~+100,-,-,-,-,SSEC

SA

DB32-00020E THERMISTOR-WIRE
ASSY
DB39-01165E CONNECT WIRE

SNA

DB61-01980A HOLDER-WIRE CLAMP

WW2-P/J,#1015 16 AWG,-,1P,-,BLU,-,175022-1
(AMP),175057-1 (AMP),TP,220V/50Hz,4mm,120mm,-,,TUBE?SSEC
AQT24W6WE,ABS,2.0,-,-,BLACK,-

SA

DB61-02893A CASE CONTROL-IN

WW2,ABS(V0),2.0,179,269,BLACK,SSEC

SA

DB63-00851A COVER-DRAIN

SS-PJT,ABS,-,-,-,-,-,NO,SSEC

SNA

WW1,JXW,4PIN,4mm,36.4*47,BLK,600V,30A

SNA

DB65-00176D TERMINAL BLOCKTERMINAL


DB68-02809A LABEL BAR CODE

-,-,-,-,W170,L115,-,-,-,FOR PACKING CASE

SNA

DB91-00309A ASSY-SCREW TAPPING WW-INV,M3*20,PH,+,ZPC(YEL)

SNA

SA

11 DB93-04128E ASSY PCB-POWER

HO5VV-F,-,250V 20A,2,000 ? 20,-,-,-,Gray,,3G*2.5,WW2,SSEC


WW2-P/J?H/P?1-STEP,POWER,SSEC

SA

12 DB93-04181A ASSY PCB MAIN

WW2-P/J,EXP,MAIN ,SSEC

SA

SA

10 DB93-01638D ASSY POWER CORD

13 DB97-02418A ASSY-SCREW TAPPING SS-P/J,TH,M4*L14

DB93-04193D
No.

Code No.

Description

Specification

QTY SA/SNA

6501-000123 CABLE TIE

DACT-140,-,W3.6,L146,NTR,NYLON66

SNA

103AT,-,-,-20~+100,-,-,-,-,SSEC

SA

DB32-00020E THERMISTOR-WIRE
ASSY
DB39-01165E CONNECT WIRE

SNA

DB61-01980A HOLDER-WIRE CLAMP

WW2-P/J,#1015 16 AWG,-,1P,-,BLU,-,175022-1
(AMP),175057-1 (AMP),TP,220V/50Hz,4mm,120mm,-,,TUBE?SSEC
AQT24W6WE,ABS,2.0,-,-,BLACK,-

SA

DB61-02893A CASE CONTROL-IN

WW2,ABS(V0),2.0,179,269,BLACK,SSEC

SA

DB63-00851A COVER-DRAIN

SS-PJT,ABS,-,-,-,-,-,NO,SSEC

SNA

DB65-00061F TERMINAL BLOCK

SNA

DB68-02809A LABEL BAR CODE

C/O,2P,N(1),1,2TAB,2SCREW,300V,20A,36.4*24.2,BLACK,N(1),1
-,-,-,-,W170,L115,-,-,-,FOR PACKING CASE

SNA

DB91-00309A ASSY-SCREW TAPPING WW-INV,M3*20,PH,+,ZPC(YEL)

SNA

HO5VV-F,-,250V 20A,2,000 ? 20,-,-,-,Gray,,3G*2.5,WW2,SSEC


WW2-P/J?C/O?0-STEP,POWER,SSEC

SA

SA

WW2-P/J,EXP,MAIN ,SSEC

SA

SA

10 DB93-01638D ASSY POWER CORD


11 DB93-04128D ASSY PCB-PAWER
FORTE
12 DB93-04181A ASSY PCB MAIN

13 DB97-02418A ASSY-SCREW TAPPING SS-P/J,TH,M4*L14

Samsung Electronics

3-27

Operating Instructions and Installation

8. Schematic Diagram
8-1. Main PCB

This Document can not be used without Samsung's authorization.

3-40

Samsung Electronics
8-1

Operating Instructions and Installation

8-2. Power PCB

This Document can not be used without Samsung's authorization.

Samsung Electronics

3-41

4. Disassembly and Reassembly


Stop operation of the air conditioner and remove the power cord before repairing the unit.

4-1 Indoor Unit


No

Parts

Front Grille

Procedure

Remark

1) Stop the air conditioner operation and


shut off the main power.

2) Open the Front Grille by pulling right and


left sides of the hook.

3) Loosen 1 of the right screw and detach


the Terminal Cover.
4) Detach the thermistor from the Front
Grille.

5) Loosen 3 fixing screws of Front Grille.

4-1

Samsung Electronics

Disassembly and Reassembly

No

Parts

Procedure

Remark

6) Unlock 3 hooks to fix Panel Front and


Tray Drain.

7) Unlock 3 hooks to fix Panel Front and


Back-Body.

Control-In
(Main PCB)

1) Take all the connector of PCB upper side


out. (Inclusion Power Cord)
2) Detach the outdoor unit connection wire
from the Terminal Block.
3) Loosen 4 fixing screws of Assy Control-In.

Tray Drain

1) Pull Tray Drain out from the Back Body.

Samsung Electronics

4-2

Disassembly and Reassembly

No

Parts

Heat Exchanger

Procedure

Remark

1) Loosen 2 fixing earth screws of right side.


2) Detach the Connection Pipe.
3) Detach the Holder Pipe at the rear side.

4) Loosen the 4 fixing screws of right and left


side.
5) Lifting the Heat Exchanger up a little to
push the up side for separation from the
indoor unit.

4-3

Fan Motor
&
Cross Fan

1) Loosen the fixing screw.


2) Detach the Fan Motor from the Fan.
3) Detach the Fan From the left Holder
Bearing.

Samsung Electronics

4-2 Outdoor Unit


12K H/P
No

Parts

Common Work

Procedure

Remark

1) Loosen the fixing screw of the


Cover Control.

2) Loosen the fixing screws on right and left,


back Cabinet-Side edge and a fixing screw
on the Cabinet-Front lower to detach the
Cabinet-Front.

3) Loosen the fixing screws of the


Assy-Control out.

4) Loosen the fixing screws of the


Cabinet-Side RH.

5) Loosen the fixing screws of the


Cabinet-Side LF.

Samsung Electronics

4-4

Operating Instructions
Disassembly
and Reassembly
and Installation

No

Parts

Fan
&
Motor

Heat Exchanger

Compressor

Procedure

Remark

1) Detach the Nut Flange.(Turn counterclockwise


because the screw is right-handed)
2) Detach the Fan.
3) Loosen 4 fixing screws to detach
the Motor.

1) Loosen 3 fixing screws of the Bar Steel.


2) Loosen 2 fixing screws on both sides.
3) Disassemble the pipe in both inlet and
outlet with welding torch.
4) Detach the Heat Exchanger.

1) Loosen the Terminal Cover nut to open the


Terminal Cover.
2) Disassemble the cloth sound felt.
3) Disassemble the pipe in both inlet and
outlet of the Compressor with welding
torch.

4) Loosen the 3 bolts at the bottom.


5) Detach the Compressor.

4-5

Samsung Electronics

12K C/O
No

Parts

Common Work

Procedure

Remark

1) Loosen 2 fixing screws and separate the


Cover Terminal.

2) Loosen 2 fixing screws and separate the


Cover Control.
3) Separate the connection wire from the
Terminal Block.

4) Loosen 6 fixing screws and separate the


Cabinet Front.

5) Loosen 1 fixing screw of Assy E-part.

6) Loosen 12 fixing screws and separate the


Cabinet-Side

Samsung Electronics

4-6

No

Parts

Fan
&
Motor

Procedure

Remark

1) Remove the Nut Flange.


(Turn to the clockwise)
2) Separate the Fan.

3) Loosen 4 fixing screws to separate the


Motor.
4) Loosen 2 fixing screws and separate the
Motor Bracket from the Base.

4-7

Heat Exchanger

1) Loosen 2 fixing screws of left and right side.


2) Disassemble the inlet and outlet pipe by
welding.
3) Separate the Heat Exchanger.

Compressor

1) Open the Terminal Cover of Compressor and


unscrew the Connection Terminal.
2) Disassemble the inlet and outlet pipe of
Compressor by welding.
3) Loosen 3 bolts of the lower part.
4) Separate the Compressor.

Samsung Electronics

MEMO

Samsung Electronics

4-8

12. Troubleshooting
Check the basic items first to judge if the problem was caused by breakdown or misuse. If none of the basic items are related to the
problem, please scrutinize the machine according to the Breakdown Diagnosis by Symptoms method.

12-1 Basic Breakdown Diagnosis Items


1. The input voltage should be rating voltage 10% range.
The airconditioner may not operate properly if the voltage is out of this range.
2. Is the link cable linking the indoor unit and the outdoor unit linked properly?
Check the terminals if the indoor unit and outdoor unit are properly linked by the same number of cables.
Otherwise the airconditioner may not operate properly.
3. When a problem occurs due to the contents illustrated in the table below it is a symptom not related to the malfunction of the
airconditioner.
No

Operation of air conditioner

Explanation

The OPERATION indication LED(GREEN) blinks when a


power plug of the indoor unit is plugged in for the first time.

It indicates power is on. The LED stops blinking if the operation


ON/OFF button on the remote control unit is pushed.

In a COOL operation mode, the compressor does not


operate at a room temperature higher than the setting
temperature that the INDOOR FAN should operate.
In a HEAT operation mode, the compressor does not operate
at a room temperature lower than the setting temperature
that indoor fan should operate.

In happens after a delay of 3 minutes when the compressor


is reoperated. The same phenomenon occurs when a power
is on.
As a phenomenon that the compressor is reoperated after a
delay of 3 minutes, the indoor fan is adjusted automatically
with reference to a temperature of the air blew.

Fan speed setting is not allowed in DRY(

Compressor stops operation intermittently in DRY(

Compressor of the outdoor unit is operating although it is


turned off in a HEAT mode.

When the unit is turned off while de-ice is activated,


the compressor continues operation for up to 9 minutes
(maximum) until the deice is completed.

Timer LED(GREEN) of the indoor unit lights up and the


air conditioner does not operate.

Timer is being activated and the unit is in ready mode.


The unit operates normally if the timer operation is cancelled.

The compressor and indoor fan stop intermittently in


HEAT mode.

The compressor and indoor fan stop intermittently if room


temperature exceeds a setting temperature in order to protect
the compressor from overheated air in a HEAT mode.

Indoor fan and outdoor fan stop operation intermittently


in a HEAT mode.

The compressor operates in a reverse cycle to remove


exterior ice in a HEAT mode, and indoor fan and outdoor fan
do not operate intermittently for within 20% of the total heater
operation

The compressor stops intermittently in a COOL mode or


DRY mode, and fan speed of the indoor unit decreases.

The compressor stops intermittently or the fan speed of the


indoor unit decreases to prevent inside/outside air frozen
depending on the inside/outside air temperature.

Samsung Electronics

The speed of the indoor fan is set to LL in DRY mode.


Fan speed is selected automatically in AUTO mode.

) mode.
) mode.

Compressor operation is controlled automatically in DRY


mode depending on the room temperature and humidity.

12-1

12-2 Trouble check in the initial status


12-2-1 Diagnosis and marking of the part in trouble.
Please check the air conditioner operation status and write the check result in the chart in the room.
LAMP
OPERATION

Description

TIMER

TURBO

Indoor unit room temperature sensor error


(open or short)
Indoor unit heat exchanger temperature sensor error
(open or short)
Indoor fan motor mal function
EEPROM error
Option error
(option wasnt set up or option data error)
: Lamp off

: Lamp flickering

12-2-2 Operation with abnormal motion


No
1

12-2

Abnormal condition
No response from
the remote control
operation signal.

Inspection

Initial Diagnosis

Plug out and plug in 5 seconds later. Able to operate the OK


remote control.

Unable to operate the Press the TURBO button with the


outdoor unit
remote control.
In 3 minutes, check the voltage
between the indoor unit terminal
block N1 and 1.

Unable to operate Press the button in the indoor unit.


the remote control. If it operates, the remote control and
indoor unit receiver are in trouble.
If not, the indoor unit is in trouble.
AC200V ~ AC240V Problem with the outdoor unit or PCB
No power source
displayed.

Problem with the relay (RY71) or PCB

Samsung Electronics

Troubleshooting

12-3 Breakdown diagnosis by symptoms


12-3-1 No Power (completely dead)-Initial diagnosis
1. Checklist :
1) Is input voltage normal?
2) Is AC power linked correctly?
3) Is input voltage of DC regulator IC KA7812 (IC01) normal? (11.8VDC-12.2VDC)
4) Is output voltage of DC regulator IC KA7805 (IC02) normal? (4.5VDC-5.5VDC)
2. Troubleshooting procedure

Unplug the power cord and plug it after 5 seconds

Press the Power Button on


the remote control unit to operate the air
conditioner

operate

Check the display board

does not operate

Check the indoor unit control board

Check whether two wires


of power cord are connected correctly to the
terminal block and control board.

No

Reconnect wires correctly

Yes

Check whether the fuse


on the control board is normal.
F701: 3.15(2.5)[A]/250[V]

No

Replace fuse

Yes

Check the output of


SMPS on the control board.
Input power: AC23015%[V]
IC02 Input: DC12[V]
IC02 output: DC5[V]

No

Replace the control board

Yes

Check the setting temperature

Samsung Electronics

12-3

Troubleshooting

12-3-2 When the Indoor Unit Fan Does Not Operate. (Initial Diagnosis)
1. Checklist :
1) Is the indoor unit fan motor properly connected with the connector (CN72)?
2) Is the AC voltage correct?
3) Is HALL IC in indoor fan motor properly connected with the connector (CN44)?
4) Is the running capacitor (CR71) properly connected with PCB board?
2. Troubleshooting procedure

After unplugging out the power cord should


be reconnected within 5 seconds.
Yes
No

Does the OPERATION lamp blink?

Check as in the procedure


"No power parts"

Yes

Does the Solid State Relay(SS71) work properly?


Test rod location
+

SS71-

SS71-

No

Micom is
out of order.

Micom
should be replaced

No

PCB is
out of order.

PCB should be
replaced.

Normal
Voltage
12V

Yes

Is the supply voltage of the fan motor sufficient?


Test rod location
PCB CN72

Condition

pin #3 and #5

Fan operate

Normal
Voltage
About AC
180V
Motor Fan-Capacitor is out of order

Yes

Fan motor
is out of order.

12-4

Replace Motor
Fan-Capacitor

Fan motor
should be replaced.

Samsung Electronics

Troubleshooting

12-3-3 When the Outdoor Unit Does Not Operate. (Initial Diagnosis)
1. Checklist :
1) Is input voltage normal?
2) Is the set temperature of the remote control higher than room temperature in COOL mode?
3) Is the set temperature of the remote control lower than room temperature in HEAT mode?
4) Is the POWER IN wire_power(N) linked correctly?
5) Is the outdoor unit properly connected with the TERMINAL BLOCK connector(N1, L1, 1, 2, 3, 4 or N1,1, 2, 3)?
2. Troubleshooting procedure
After unplugging out the power cord should be
reconnected within 5 seconds.

No

Does the OPERATION lamp blink

Check as in the procedure


"No Power parts"

Yes

Room temperature sensor is


out of order

Yes

Does the timer lamp blink during operation?

No
@

#
No

Is the power relay RY71 operated by adjusting


the room temperature?
Test rod location
+

Condition

IC04 Pin No.38

GND

RY71 ON

PCB should be checked.

Micom is
out of order.

Normal
Voltage

PCB should be checked.

DC4.8V

Yes

Is rating voltage 10% range applied relay between


Terminal block No. N1 and No. 1

No

Power relay is
out of order

Power relay should be


replaced.

Yes

Outdoor unit is out of order.


No

!
Yes

Is the room sensor normal register?


10C

20C

30C

17.96k

12.09k

8.3k

Samsung Electronics

12-5

Troubleshooting

12-3-4 When the UP/DOWN Louver Motor Does Not Operate. (Initial Diagnosis)
1. Checklist :
1) Is input voltage normal?
2) Is the UP/DOWN louver motor properly connected with the connector (CN61)?
2. Troubleshooting procedure

Remove power cord and plug in again approx.


5 seconds.

Does the OPERATION lamp blink?

No

Check as in the procedure


"No Power parts".

Yes

Does operation start when


swing button of the remote control unit
pushed?

Yes

Normal

No

Voltage at pin #57~#60


of micom (IC04) change?
(Squarewave)

No

Micom (IC04) is faulty.

Yes

Voltage at pin #14 ~ #16 of


IC06(ULN2003A) and pin 14#
of IC05 change?(Squarewave)

No

Driver IC05/06 (ULN2003A) is faulty.

Yes

UP/DOWN louver motor is faulty.

12-6

Samsung Electronics

Troubleshooting

12-3-5 In the HEAT mode, When there is no warm air current. Check this first;
1) Is the set temperature of Remote Control lower than room temperature in Heat mode?
2) Is the Indoor PCB properly connected with WIRE[power(N),fan(H),4-way,fan(L)]?

After training on, the heating operation


should start in 5 minutes.
No

Is the number #38 of Micom (IC04)


DC5.0V?

No

Abnormal Micom

Yes

Is the number checking


#13 of IC05 (ULN2003A) LOW?

No

Abnormal Micom

Yes

Is the voltage between


CN71 #1 and CN71 #5 rating voltage
10% range

No

Abnormal IC05

Yes

Abnormal 4-Way valve of Outdoor Unit.


or connecting Cable

4-Way valve should be replaced


or connecting Cable Check.

Samsung Electronics

No

Abnormal RY73

PCB should be replaced.

12-7

Troubleshooting

12-3-6 Room temperature sensor failure


LAMP
OPERATION

Description

TIMER

TURBO

Indoor unit room temperature sensor error(open or short)


: Lamp off

: Lamp flickering

Detach the assembly sensor from the


ASS'Y PCB CN43 connector and measure
the sensor resistance with an ohmmeter (tester).

Is the sensor resistance value


10K 3% at the room temperature
of 25C?

No

ASS'Y Sensor Replace


SENSOR Resistance Value : 20C-12.09k
SENSOR Resistance Value : 30C-8.31k
SENSOR Resistance Value : 35C-6.94k
SENSOR Resistance Value : 40C-5.83k

Yes

Connect the sensor to CN43,


supply power, and measure the voltage of
#1 and #2 of the CN43 connector.

Yes

Poor ASS'Y PCB Replace

Below 0.5V?

No

Yes

Over 4.9V?

Poor ASS'Y PCB Replace

No

MICOM Error or Connector(CN43) check

12-8

Samsung Electronics

Troubleshooting

12-3-7 Room Pipe sensor failure


LAMP
OPERATION

Description

TIMER

TURBO

Indoor unit heat exchanger temperature sensor error


(open or short)
: Lamp off

: Lamp flickering

1. Check the assembly condition of the sensor connector(CN43) on the indoor unit Main PCB and if not assembled, reassemble the
connector accurately.
2. Detach the room pipe sensor connector(CN43) and check the resistance between connector 3 and 4.
Temperature(C)

Resistance Value(Kohm)

Temperature(C)

Resistance Value(Kohm)

15

14.68

30

8.31

20

12.09

35

6.94

25

10

40

5.83

Others
The data tolerance
is 3%.

If the above data is not met, replace the room pipe sensor.
3. Assemble the room pipe sensor to PCB, plug in, and check the voltage of connector 3 and 4. If the resistance is below 0.5V or
over 4.9V, replace the indoor Main PCB. (short or disconnected in the PCB board)

12-3-8 When the remote control is not receiving.


1. Check if the connector was normally assembled.
2. Put the set in operation and check the voltage of Vout(+) and Gnd(-) of the RM01 while operating the
remote control. When the voltage descends below 3V, the assembly module PCB is normal and the main PCB is poor.
Then replace the main PCB.

Samsung Electronics

12-9

12-4 PCB Inspection Method


12-4-1 Pre-inspection Notices
1. Check if you pulled out the AC power plug when you eliminate the PCB or front panel.
2. Don't hold the PCB side not impose excessive force on it to eliminate the PCB.
3. Don't pull the lead wire but hold the whole housing to connect or disconnect a connector to the PCB.

12-4-2 Inspection Procedure


1. Check connector connection and peeling of PCB or bronze coating pattern when you think the PCB is broken.
2. The PCB is composed of the 2 parts.
POWER PCB Part : relay, room fan motor driving circuit and control circuit,
power circuit of DC12V and DC5V, and buzzer driving circuit.
Main PCB Part: MICOM and surrounding circuit,LED lamp,sensor driving circuit,Switch

12-4-3 Detailed Inspection Procedure


No

Procedure

Plug out and pull the PCB


out of the electronic box.
Check the PCB fuse.

1) Is the fuse disconnected? (F701)

Supply power.
If the operating lamp
twinkles at this time,
the above 1)~3) have
no relation.

Checking the power voltage.

Press the ON/OFF button


and operate TURBO
mode.
But, exclude the
RESERVE operation.

Inspection Method

Overcurrent
Indoor Fan Motor Short
AC Part Pattern Short of the MAIN PCB

1) Is the wire_power(N) and comp_RY71 input voltage


AC200V~AC240V?

Power Cord is fault, Fuse open. Wrong


Power Cable Wiring, AC Part is faulty.

2) Is the voltage between both terminals of the


C103 on the 2nd side of the transformer AC12V
0.5V?

Switching Trans or Power Circuit is faulty

3) Is the voltage between both terminals of OUT


and GND of IC02(KA78L05) DC5V 0.5V?

Power Circuit is faulty, Load Short

Checking the power voltage.


1) Check the voltage of the relay(RY71) coil(IC05 PIN
#13 and GND : 0V, PIN#4 and GND : 5V) during
operation(3 minutes after TURBO operation).

Relay(RY71) Coil Disconnection, IC05 is


faulty

2) Check the voltage of both terminals of


terminal block 1 and N1 after 3 minute
operation.: AC220V

Relay(RY71) Contact is faulty

Press the ON/OFF button. 1) Is the voltage over AC180V being imposed
on terminal #3 and #5 of the fan motor
1. FAN Speed [High]
connector(CN72)?
2. Continuous Operation

12-10

Cause

Fan Motor of the indoor is faulty

2) The fan motor of the indoor unit doesn't run.

Fan Motor Connector(CN72) is faulty

3) The power voltage between terminal #3 and #5


of the connector(CN72) is 0V.

ASS'Y POWER OR MAIN PCB is faulty


Connection is faulty

Samsung Electronics

Troubleshooting

12-4-4 Temperature Sensor Feature Conversion Table(Room Temperature Sensor); 103AT


Temperature Sensor Resistance Temperature Sensor Resistance Temperature Sensor Resistance Temperature Sensor Resistance
[C]
[C]
[C]
[C]
[Kohm]
[Kohm]
[Kohm]
[Kohm]
70
69
68
67
66
65
64
63
62
61
60

2.229
2.296
2.365
2.437
2.512
2.589
2.669
2.752
2.838
2.928
3.021

49
48
47
46
45
44
43
42
41
40

4.300
4.444
4.594
4.749
4.912
5.080
5.256
5.439
5.630
5.828

29
28
27
26
25
24
23
22
21
20

8.622
8.944
9.281
9.632
10
10.380
10.780
11.200
11.630
12.090

9
8
7
6
5
4
3
2
1
0

18.700
19.480
20.290
21.150
22.050
22.990
23.900
25.030
26.130
27.280

59
58
57
56
55
54
53
52
51
50

3.116
3.216
3.319
3.426
3.537
3.652
3.772
3.897
4.026
4.161

39
38
37
36
35
34
33
32
31
30

6.033
6.246
6.468
6.699
6.941
7.192
7.455
7.729
8.015
8.313

19
18
17
16
15
14
13
12
11
10

12.560
13.060
13.570
14.120
14.680
15.280
15.900
16.550
17.240
17.960

-1
-2
-3
-4
-5
-6
-7
-8
-9

28.470
29.720
31.040
32.430
33.890
35.430
37.050
38.760
40.560

Temperature Sensor Characteristic Curve


Temperature
( C)
70
60
50
40
30

At the temperature of 25 C(10K)

20
10
0
-10
-9
5

10

15

20

25

30

35

40

Resistance Value (Kohm)

Samsung Electronics

12-11

12-5 Main Part Inspection Method


Part
Room Temperature Sensor

Room Fan Motor

Breakdown Inspection Method


Measure resistance with a tester
Normal

At the normal temperature 37k~8.3k(-7C~+30C) *Refer to Table 12-3-4.

Abnormal

, 0. . . Open or Short

Measure the resistance between terminals of the connector (CN72) with a tester.
Abnormal

Outdoor Fan Motor

Measure the resistance between motor wires with a tester.


Abnormal

Stepping Motor

12-12

, 0. . . Open or Short

, 0. . . Open or Short

Measure the resistance between the red wire and each terminal wire with a tester.
Normal

About 300 at the normal temperature (20C ~ 30C)

Abnormal

, 0. . . Open or Short

Samsung Electronics

MEMO

Samsung Electronics

12-13

3. Alignment and Adjustments


3-1 Test Mode
How to Approach Test Mode
You can approach the Test Mode by pressing the on/off switch of
indoor unit for 5 seconds.

on/off switch

Test Mode Operation Option


After installing the air conditioner, check whether each subordinate is normally operated or not by operating the Test Mode.
Temperature Display Part : Display the set option at one-second intervals. (Only for models having the temperature display part)
ex) 0b0000-1730F8 : 0b00001730F80b ...(Repeat)
When an error occurs, display the Error Mode.
LED Display
LAMP
Waiting Operation

OPERATION

TIMER

TURBO

Cause

Indoor temperature
sensor error
(OPEN /SHORT)

Follow-up Measures

Check assembling status of the sensor parts


connector on the indoor unit main PCB
Measure the resistance value on both sides
connector no. 1 and no. 2 (E1), no. 3 and no. 4
(E2) by separating the sensor parts connector
Temp. Resistance Temp. Resistance
(C) Value(K) (C) Value(K)

Indoor heat exchanger


temperature sensor error
(OPEN /SHORT)

15

14.68

30

8.31

20

12.09

35

6.94

25

10.00

40

5.83

Others
The error of
DATA is
2%.

* If not meet the above DATA, replace sensors.

Indoor fan motor speed


detecting error
(Occur when it continues
for 15 seconds at below
450rpm)

Check assembling status of the Motor Hall IC


output connector (CN44) on the indoor unit
main PCB

EEPROM error
(Option memory)
* Display only for models
having the returning
function for the power failure

Blink all lamps

Samsung Electronics

When there is an option


related error
When options are not set
When there is an option
data error

Reset options
Replace the PCB

Reset options

3-1

Alignment and Adjustments

Test Mode Operation Option(cont.)


Operation Mode : Cool mode. Operate the cool mode by operating the compressor by force without the compressor ON/OFF
according to the set temperature/indoor temperature. (Do not follow the antifreeze control)
Up-down louver : Up-down swing mode
Indoor Fan : High

Because the Test Mode operate the cool mode by force not related to the set temperature / indoor temperature, check
whether each subordinate is operated normally or not after completing installation and must turn off the power of the
air conditioner.

3-2

Samsung Electronics

3-2 Error Mode and Check Method


LAMP
Description

OPERATION

TIMER

TURBO

Indoor unit room temperature sensor error


(open or short)
Indoor unit heat exchanger temperature sensor error
(open or short)
Indoor fan motor mal function
EEPROM error
Option error
(option wasnt set up or option data error)
: Lamp off

Samsung Electronics

: Lamp flickering

3-3

Alignment and Adjustments

3-2-1 Room temperature sensor Error


LAMP
Description

OPERATION

TIMER

TURBO

Indoor unit room temperature sensor error


(open or short)

Detach the assembly sensor from the


ASS'Y main PCB CN43 connector and measure
the sensor resistance with an ohmmeter (tester)
between Pin #1 and #2.

Is the sensor resistance value


10K3% at the room temperature
of 25C?

No

ASS'Y Sensor Replace


SENSOR Resistance Value : 20C-12.09k
30C-8.31k
35C-6.94k
40C-5.83k

Yes
Connect the sensor to CN43,
supply power, and measure the voltage of
#1 and #2 of the CN43 connector.

Below 0.5V?

Yes

Poor ASS'Y PCB Replace

No
Over 4.9V?

Yes

Poor ASS'Y PCB Replace

No
MICOM Error or Connector(CN43) check

3-4

Samsung Electronics

Alignment and Adjustments

3-2-2 Room Pipe sensor Error


LAMP
OPERATION

Description

TIMER

TURBO

Indoor unit heat exchanger temperature sensor error


(open or short)
1. Check the assembly condition of the sensor connector(CN43) on the indoor unit Main PCB and if not assembled, reassemble
the connector accurately.
2. Detach the room pipe sensor connector(CN43) and check the resistance between Pin #3 and #4.
Temperature(C)

Resistance Value(Kohm)

Temperature(C)

Resistance Value(Kohm)

15

14.68

30

8.31

20

12.09

35

6.94

25

10

40

5.83

Others
The data tolerance
is 3%.

If the above data is not met, replace the room pipe sensor.
3. Assemble the room pipe sensor to PCB, plug in, and check the voltage of connector 3 and 4. If the resistance is below 0.5V or
over 4.9V, replace the indoor Main PCB. (short or disconnected in the PCB board)

Samsung Electronics

3-5

Alignment and Adjustments

3-2-3 Indoor Unit Fan Motor Error


LAMP
OPERATION

Description

TIMER

TURBO

Indoor fan motor mal function

1. Checklist :
1) Is the indoor unit fan motor properly connected with the connector (CN72)?
2) Is the AC voltage correct?
3) Is HALL IC in indoor fan motor properly connected with the connector (CN44)?
4) Is the running capacitor (CR71) properly connected with PCB board?
2. Troubleshooting procedure
After unplugging out the power cord should
be reconnected within 5 seconds.
Yes
Does the OPERATION lamp blink?

No

Check as in the procedure "No Power".

Yes
Does the Solid State Relay(SS71) work properly?
Test rod location
+

SS71-

SS71-

No

Micom is
out of order.

Micom should be replaced

No

PCB is
out of order.

PCB should be replaced.

Normal
Voltage
12V
Yes

Is the power relay RY71 operated by


adjusting the room temperature?
Test rod location

PCB CN72

Condition

Normal
Voltage

pin #3 and #5

Fan operating

About AC180V
Motor Fan-Capacitor is out of order

Yes

Fan motor is out of order.

3-6

Replace Motor
Fan-Capacitor

Fan motor should be replaced.

Samsung Electronics

3-3 Setting Option Setup Method

Option No. :
Step 1 : Enter the Option Setup mode.
1st

Take out the batteries of remote control.

2nd

Press the temp.

button simultaneously and

insert the battery again.


3rd

Make sure the remote control display shown as

Step 2 : Enter the Option Setup mode and select your option according to the following procedure.

1
The default value is
Otherwise, push the

.
button to

Every time you push the button, the display panel reads
repeatedly.
1

Push the

button to set the display panel to

Every time you push the button, the display panel reads
...
repeatedly.

5
6

button to set the display panel to

Every time you push the button, the display panel reads
...
repeatedly.

Push the

or

Push the

button to set the display panel to

Every time you push the button, the display panel reads
...
repeatedly.

Push the

button to set the display panel to

Every time you push the button, the display panel reads
...
repeatedly.
Setting is not required if you must
a value which has a default.

Push the

button to set the display panel to

Every time you push the button, the display panel reads
...
repeatedly.

7
8

Samsung Electronics

10

3-7

Alignment and Adjustments

7
Press

Push the

button, then the default value is

button to set the display panel to

Every time you push the button, the display panel reads
...
repeatedly.

7
8
9

Push the

button to set the display panel to

Every time you push the button, the display panel reads
...
repeatedly.

10

11

10

12

Push the

button to set the display panel to

Every time you push the button, the display panel reads
...
repeatedly.

11

Push the

button to set the display panel to

Every time you push the button, the display panel reads
...
repeatedly.

12

Setting is not required if you must


a value which has a default.

Push the

button to set the display panel to

Every time you push the button, the display panel reads
...
repeatedly.

Step 3 : Upon completion of the selection, check you made right selections.
to set the display part to and check the display part.
Press the Mode Selection key,
The display part shows

Press the Mode Selection key,


The display part shows

to set the display part to

and check the display part.

Step 4 : Pressing the ON/OFF button ( )


When pressing the operation ON/OFF key with the direction of remote control for unit, the sound ''Ding'' or ''Diriring'' is
heard and the OPERATION ICON( ) lamp of the display is flickering at the same time, then the input of option is completed. (If the diriring sound isn't heard, try again pressing the ON/OFF button.)

Step 5 : Unit operation test-run


First, Remove the battery from the remote control.
Second, Re-insert the battery into the remote control.
Third, Press ON/OFF button(

) with the direction of remote control for set.

Error Mode
1stIf all lamps of indoor unit are flickering, Plug out, plug in power plug again and press ON/OFF key to retry.
2nd If the unit is not working properly or all lamps are continuously flickering after setting the option code, see if the correct option
code is set up for its model.

3-8

Samsung Electronics

Alignment and Adjustments

OPTION ITEMS
REMOCON
SEG1

SEG2

SEG3

SEG4

SEG5

SEG6

SEG7

SEG8

SEG9

SEG10

SEG11

SEG12

AQ12FA

AQ12FASER

AS12FAXFA

AS12FBAXAP

MODEL

Samsung Electronics

3-9

13. Block Diagram


*: OPTION

CONTROLLER
IC-MCU
HEAT EXCHANGER SENSOR
ROOM TEMPERATURE SENSOR
INFRARED SIGNAL
RESET
CIRCUIT

BLADE CONTROL
INDOOR FAN MOTOR CONTROL
COMPRESSOR CONTROL
OUTDOOR FAN MOTOR CONTROL
4 WAY VALVE CONTROL (*)
TEMPERATURE CONTROL
TIMER
BUZZER CONTROL

DISPLAY PART
OPERATION
TURBO
TIMER

OSCILLATION
CIRCUIT
ZERO
VOLTAGE
DETECT

REMOTE CONTROL

POWER ON/OFF

MODE
(AUTO, COOL, DRY,
FAN),HEAT*

COMPRESSOR CONTROL SIGNAL


OUTDOOR FAN MOTOR CONTROL
SIGNAL
4 WAY VALVE CONTROL SIGNAL*
STEPPING MOTOR CONTROL
SIGNAL
BUZZER CONTROL SIGNAL

TRIGGER
SIGNAL

INDOOR FAN MOTOR

SSR

TURBO OPERATION

FAN SPEED SELECT


(H/M/L/AUTO)

COMPRESSOR DRIVE
OUTDOOR FAN MOTOR DRIVE
4 WAY VALVE DRIVE*
STEPPING MOTOR DRIVE
BUZZER DRIVE

COMPRESSOR
OUTDOOR FAN MOTOR
4 WAY VALVE*
BUZZER

STEPPING MOTOR
: BLADE UP/DOWN

FLAP

DC5V
ON, OFF TIMER
SELECT

TEMPERATURE
SELECT(UP/DOWN)

VOLTAGE REGULATOR

DC12V
SMPS POWER BLOCK

GOOD MORNING
OPERATION

AC INPUT

13-1

Samsung Electronics

Block Diagram

DISPLAY PART

REMOTECONTROL PART
INDOOR FAN CONTROL PART

AC/DC PART
CONNECT
C/W MAIN
PBA

ZERO CROSSING PART


Samsung Electronics

BUZZER CONTROL PART


13-2

10. PCB Diagram


The red number connecter is not used.
8

10

11

14

12

13

Power

Temperature Sensor

Motor RPM Feedback

BLADE-H Motor

Remocon Module

10

HVPS(High voltage Generator)

Humidity Sensor

11

DISPLAY PCB Connection

Anios

12

Melody PCB Connection

Auto grill 1

13

Test Board Connection

Auto grill 2

14

Indoor Fan Motor

Samsung Electronics

10-1

7. Wiring Diagram
H/P

This Document can not be used without Samsung's authorization.

7-1

Samsung Electronics

C/O

This Document can not be used without Samsung's authorization.

Samsung Electronics

7-2

6. Electrical Parts List


MAIN PCB : DB93-04128A
Location No.

Code No.

Description

D101
D102
D103
D104
D105
Q601
Q101

0402-000137
0402-000137
0402-000137
0402-000137
0402-000137
0501-000303
0501-000398

Q102

0501-000398 TR-SMALL SIGNAL

Q602

0501-000398 TR-SMALL SIGNAL

Q603

0501-000398 TR-SMALL SIGNAL

ICO1

1203-000243 IC-POSI.FIXED REG.

ICO2
VA71
R103
R104
R105
R605
R606
R609
R610
R102
R608
R602
R603
R601
R101
R607
C107
C108
C102
C104
C106
CR71

1203-000429
1405-000154
2001-000429
2001-000429
2001-000429
2001-000429
2001-000429
2001-000429
2001-000429
2001-000591
2001-000734
2001-000780
2001-000780
2001-000855
2007-000290
2007-000290
2202-000128
2202-000128
2202-000780
2202-000780
2202-000780
2301-001363

IC-POSI.FIXED REG.
VARISTOR
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CHIP
R-CHIP
C-CERAMIC,MLC-AXIAL
C-CERAMIC,MLC-AXIAL
C-CERAMIC,MLC-AXIAL
C-CERAMIC,MLC-AXIAL
C-CERAMIC,MLC-AXIAL
C-FILM,LEAD-PPF

XC71
C101
C103
C601
C105
BZ61
RY72

2301-001439
2401-000173
2401-000711
2401-002300
2401-003036
3002-001129
3501-001154

C-FILM,LEAD-PPF
C-AL
C-AL
C-AL
C-AL
BUZZER-PIEZO
RELAY-MINIATURE

RY73

3501-001154 RELAY-MINIATURE

RY74

3501-001154 RELAY-MINIATURE

RY71
SS71
F701
F702
CN72

3501-001268
3502-000115
3601-000263
3601-001209
3711-000262

6-1

DIODE-RECTIFIER
DIODE-RECTIFIER
DIODE-RECTIFIER
DIODE-RECTIFIER
DIODE-RECTIFIER
TR-SMALL SIGNAL
TR-SMALL SIGNAL

RELAY-POWER
SSR
FUSE-CARTRIDGE
FUSE-RADIAL LEAD
HEADER-BOARD TO
CABLE

Specification

QTY

1N4007,1KV,1A,DO-41,TP
1N4007,1KV,1A,DO-41,TP
1N4007,1KV,1A,DO-41,TP
1N4007,1KV,1A,DO-41,TP
1N4007,1KV,1A,DO-41,TP
KSA733,PNP,250mW,TO-92,TP,120-240
KSC945-Y,NPN,250mW,TO92,TP,120-240
KSC945-Y,NPN,250mW,TO92,TP,120-240
KSC945-Y,NPN,250mW,TO92,TP,120-240
KSC945-Y,NPN,250mW,TO92,TP,120-240
7812,TO-220,3P,-,PLASTIC,11.5/
12.5V,16W,0TO+125C,1A,-,ST,78L05A,TO-92,3P,-,PLASTIC,4.6/
460Vdc,2500A,17.5x7.5mm,TP
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
3.3KOHM,5%,1/8W,AA,TP,1.8X3.2MM
4.7KOHM,5%,1/8W,AA,TP,1.8X3.2MM
470OHM,5%,1/8W,AA,TP,1.8X3.2MM
470OHM,5%,1/8W,AA,TP,1.8X3.2MM
560OHM,5%,1/4W,AA,TP,2.4X6.4MM
100ohm,5%,1/8W,TP,2012
100ohm,5%,1/8W,TP,2012
10nF,+80-20%,50V,Y5V,TP,2.5x4.
10nF,+80-20%,50V,Y5V,TP,2.5x4.
100nF,+80-20%,50V,Y5V,-,3.5x19mm,100nF,+80-20%,50V,Y5V,-,3.5x19mm,100nF,+80-20%,50V,Y5V,-,3.5x19mm,2000nF,+105%,450V,BK,38x18x30mm,33
220nF,10%,275V,BK,18x10x15.8mm,15
1000uF,20%,35V,GP,TP,13x25,5
2200uF,20%,25V,GP,TP,16x25,7.5
47?F,20%,50V,GP,TP,6.3x11,5mm
100uF,20%,16V,GP,TP,5X11mm,5mm
85DB,-,-,2KHZ,12Vdc,200mW,3000mA,1FormA,10mS,
10mS
12Vdc,200mW,3000mA,1FormA,10mS,
10mS
12Vdc,200mW,3000mA,1FormA,10mS,
10mS
12V,0.9W,25000mA,SPST,20mS,10mS
12Vdc,-,2A,1mS,1mS
250V,3.15A,TIME-LAG,GLASS,5x20mm
250V,1A,TIME-LAG,-,8.5x8mm
1WALL,3P,1R,7.92MM,STRAIGHT,SN,
WHT

1
1
1
1
1
1
1

SA/SNA Remark
SNA
SNA
SNA
SNA
SNA
SNA
SNA

SNA

SNA

SNA

SNA

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA

1
1
1
1
1
1
1

SNA
SNA
SNA
SNA
SNA
SNA
SA

SA

SA

1
1
1
1
1

SA
SNA
SNA
SNA
SNA

Samsung Electronics

MAIN PCB : DB93-04128A(cont.)


Location No.
CN73

Code No.

Description

J1

3711-003845 HEADER-BOARD TO
CABLE
3812-001283 WIRE-NO SHEATH CU

J2

3812-001283 WIRE-NO SHEATH CU

J3

3812-001283 WIRE-NO SHEATH CU

J4

3812-001283 WIRE-NO SHEATH CU

J5

3812-001283 WIRE-NO SHEATH CU

J6

3812-001283 WIRE-NO SHEATH CU

J7

3812-001283 WIRE-NO SHEATH CU

J8

3812-001283 WIRE-NO SHEATH CU

TR-1
TR-2
TR-3
TR-4
4-WAY
FAN(H)
FAN(L)
POWER(N)
RY-1
RY-2
RY-3
RY-4
ST11

6042-000105
6042-000105
6042-000105
6042-000105
6042-001009
6042-001009
6042-001009
6042-001009
6042-001009
6042-001009
6042-001009
6042-001009
DB26-00066A

POWER(N)

DB39-01270E CONNECT WIRE

FAN(H)

DB39-01270F CONNECT WIRE

4-WAY

DB39-01270G CONNECT WIRE

FAN(L)

DB39-01270H CONNECT WIRE

EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
TRANS POWER

DB41-00495A PCB-POWER
F701

DB61-00924A HOLDER-FUSE
DB62-03085A HEAT SINK

Samsung Electronics

Specification

QTY

SA/SNA Remark

BOX,11P,1R,2mm,STRAIGHT,SN,WHT

SNA

TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,ID1.6,OD2.0,L6,NI PLT,C2600BD
ID1.6,OD2.0,L6,NI PLT,C2600BD
ID1.6,OD2.0,L6,NI PLT,C2600BD
ID1.6,OD2.0,L6,NI PLT,C2600BD
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
-,WW2-VE,-,8-PIN,230V/AC,16.5V/
DC,400mA,-,50hz,-,-,-,-,-,SSEC
WW2-P/J,#1015 18 AWG,-,1P,,BLU,-,175022-1 (AMP),ST780400
(KET),TP,220V/50Hz,4mm,170mm,-,,TUBE?SSEC
WW2-P/J,#1015 18 AWG,-,1P,,RED,-,175022-1 (AMP),ST780400
(KET),TP,220V/50Hz,4mm,160mm,-,,TUBE?SSEC
WW2-P/J,#1015 18 AWG,-,1P,,BLK,-,175022-1 (AMP),ST780400
(KET),TP,220V/50Hz,4mm,160mm,-,,TUBE?SSEC
WW2-P/J,#1015 18 AWG,-,1P,,BLU,-,175022-1 (AMP),ST780400
(KET),TP,220V/50Hz,4mm,160mm,-,,TUBE?SSEC
WW2-P/J,FR-1,ONELAYER,VERSION1,T1.6,-,-,-,-,SSEC
-,FH-51B,-,-,-,-,SSEC
-,A6063,25,15,15,-,-,SSEC

SNA

SNA

SNA

SNA

SNA

SNA

SNA

SNA

1
1
1
1
1
1
1
1
1
1
1
1
1

SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA

SNA

SNA

SNA

SNA

SNA

1
1

SNA
SNA

6-2

Electrical Parts List

MAIN PCB : DB93-04128B


Location No.

Code No.

Description

D101
D102
D103
D104
D105
Q601
Q101

0402-000137
0402-000137
0402-000137
0402-000137
0402-000137
0501-000303
0501-000398

DIODE-RECTIFIER
DIODE-RECTIFIER
DIODE-RECTIFIER
DIODE-RECTIFIER
DIODE-RECTIFIER
TR-SMALL SIGNAL
TR-SMALL SIGNAL

Q102

0501-000398

TR-SMALL SIGNAL

Q602

0501-000398

TR-SMALL SIGNAL

Q603

0501-000398

TR-SMALL SIGNAL

ICO1

1203-000243

IC-POSI.FIXED REG.

ICO2
VA71
R103
R104
R105
R605
R606
R609
R610
R102
R608
R602
R603
R601
R101
R607
C107
C108
C102
C104
C106
CR71

1203-000429
1405-000154
2001-000429
2001-000429
2001-000429
2001-000429
2001-000429
2001-000429
2001-000429
2001-000591
2001-000734
2001-000780
2001-000780
2001-000855
2007-000290
2007-000290
2202-000128
2202-000128
2202-000780
2202-000780
2202-000780
2301-001363

IC-POSI.FIXED REG.
VARISTOR
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CHIP
R-CHIP
C-CERAMIC,MLC-AXIAL
C-CERAMIC,MLC-AXIAL
C-CERAMIC,MLC-AXIAL
C-CERAMIC,MLC-AXIAL
C-CERAMIC,MLC-AXIAL
C-FILM,LEAD-PPF

XC71
C101
C103
C601
C105
BZ61
RY72

2301-001439
2401-000173
2401-000711
2401-002300
2401-003036
3002-001129
3501-001154

C-FILM,LEAD-PPF
C-AL
C-AL
C-AL
C-AL
BUZZER-PIEZO
RELAY-MINIATURE

RY74

3501-001154

RELAY-MINIATURE

RY71
SS71
F701
F702
CN72

3501-001268
3502-000115
3601-000263
3601-001209
3711-000262

CN73

3711-003845

RELAY-POWER
SSR
FUSE-CARTRIDGE
FUSE-RADIAL LEAD
HEADER-BOARD TO
CABLE
HEADER-BOARD TO
CABLE

6-3

Specification

QTY

SA/SNA Remark

1N4007,1KV,1A,DO-41,TP
1N4007,1KV,1A,DO-41,TP
1N4007,1KV,1A,DO-41,TP
1N4007,1KV,1A,DO-41,TP
1N4007,1KV,1A,DO-41,TP
KSA733,PNP,250mW,TO-92,TP,120-240
KSC945-Y,NPN,250mW,TO92,TP,120-240
KSC945-Y,NPN,250mW,TO92,TP,120-240
KSC945-Y,NPN,250mW,TO92,TP,120-240
KSC945-Y,NPN,250mW,TO92,TP,120-240
7812,TO-220,3P,-,PLASTIC,11.5/
12.5V,16W,0TO+125C,1A,-,ST,78L05A,TO-92,3P,-,PLASTIC,4.6/
460Vdc,2500A,17.5x7.5mm,TP
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
3.3KOHM,5%,1/8W,AA,TP,1.8X3.2MM
4.7KOHM,5%,1/8W,AA,TP,1.8X3.2MM
470OHM,5%,1/8W,AA,TP,1.8X3.2MM
470OHM,5%,1/8W,AA,TP,1.8X3.2MM
560OHM,5%,1/4W,AA,TP,2.4X6.4MM
100ohm,5%,1/8W,TP,2012
100ohm,5%,1/8W,TP,2012
10nF,+80-20%,50V,Y5V,TP,2.5x4.
10nF,+80-20%,50V,Y5V,TP,2.5x4.
100nF,+80-20%,50V,Y5V,-,3.5x19mm,100nF,+80-20%,50V,Y5V,-,3.5x19mm,100nF,+80-20%,50V,Y5V,-,3.5x19mm,2000nF,+105%,450V,BK,38x18x30mm,33
220nF,10%,275V,BK,18x10x15.8mm,15
1000uF,20%,35V,GP,TP,13x25,5
2200uF,20%,25V,GP,TP,16x25,7.5
47?F,20%,50V,GP,TP,6.3x11,5mm
100uF,20%,16V,GP,TP,5X11mm,5mm
85DB,-,-,2KHZ,12Vdc,200mW,3000mA,1FormA,10mS,
10mS
12Vdc,200mW,3000mA,1FormA,10mS,
10mS
12V,0.9W,25000mA,SPST,20mS,10mS
12Vdc,-,2A,1mS,1mS
250V,3.15A,TIME-LAG,GLASS,5x20mm
250V,1A,TIME-LAG,-,8.5x8mm
1WALL,3P,1R,7.92MM,STRAIGHT,SN,
WHT
BOX,11P,1R,2mm,STRAIGHT,SN,WHT

1
1
1
1
1
1
1

SNA
SNA
SNA
SNA
SNA
SNA
SNA

SNA

SNA

SNA

SNA

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA

1
1
1
1
1
1
1

SNA
SNA
SNA
SNA
SNA
SNA
SA

SA

1
1
1
1
1

SA
SNA
SNA
SNA
SNA

SNA

Samsung Electronics

Electrical Parts List

MAIN PCB : DB93-04128B(cont.)


Location No.

Code No.

Description

J1

3812-001283

WIRE-NO SHEATH CU

J2

3812-001283

WIRE-NO SHEATH CU

J3

3812-001283

WIRE-NO SHEATH CU

J4

3812-001283

WIRE-NO SHEATH CU

J5

3812-001283

WIRE-NO SHEATH CU

J6

3812-001283

WIRE-NO SHEATH CU

J7

3812-001283

WIRE-NO SHEATH CU

J8

3812-001283

WIRE-NO SHEATH CU

TR-1
TR-2
TR-3
TR-4
FAN(H)
FAN(L)
POWER(N)
RY-1
RY-2
RY-3
RY-4
ST11

6042-000105
6042-000105
6042-000105
6042-000105
6042-001009
6042-001009
6042-001009
6042-001009
6042-001009
6042-001009
6042-001009
DB26-00066A

EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
TRANS POWER

POWER(N)

DB39-01270E

CONNECT WIRE

FAN(H)

DB39-01270F

CONNECT WIRE

FAN(L)

DB39-01270H

CONNECT WIRE

DB41-00495A

PCB-POWER

DB61-00924A
DB62-03085A

HOLDER-FUSE
HEAT SINK

F701

Samsung Electronics

Specification
TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,ID1.6,OD2.0,L6,NI PLT,C2600BD
ID1.6,OD2.0,L6,NI PLT,C2600BD
ID1.6,OD2.0,L6,NI PLT,C2600BD
ID1.6,OD2.0,L6,NI PLT,C2600BD
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
-,WW2-VE,-,8-PIN,230V/AC,16.5V/
DC,400mA,-,50hz,-,-,-,-,-,SSEC
WW2-P/J,#1015 18 AWG,-,1P,,BLU,-,175022-1 (AMP),ST780400
(KET),TP,220V/50Hz,4mm,170mm,-,,TUBE?SSEC
WW2-P/J,#1015 18 AWG,-,1P,,RED,-,175022-1 (AMP),ST780400
(KET),TP,220V/50Hz,4mm,160mm,-,,TUBE?SSEC
WW2-P/J,#1015 18 AWG,-,1P,,BLU,-,175022-1 (AMP),ST780400
(KET),TP,220V/50Hz,4mm,160mm,-,,TUBE?SSEC
WW2-P/J,FR-1,ONELAYER,VERSION1,T1.6,-,-,-,-,SSEC
-,FH-51B,-,-,-,-,SSEC
-,A6063,25,15,15,-,-,SSEC

QTY

SA/SNA Remark

SNA

SNA

SNA

SNA

SNA

SNA

SNA

SNA

1
1
1
1
1
1
1
1
1
1
1
1

SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA

SNA

SNA

SNA

SNA

1
1

SNA
SNA

6-4

Electrical Parts List

MAIN PCB : DB93-04128D


Location No.

Code No.

Description

D101
D102
D103
D104
D105
Q601
Q101

0402-000137
0402-000137
0402-000137
0402-000137
0402-000137
0501-000303
0501-000398

DIODE-RECTIFIER
DIODE-RECTIFIER
DIODE-RECTIFIER
DIODE-RECTIFIER
DIODE-RECTIFIER
TR-SMALL SIGNAL
TR-SMALL SIGNAL

Q102

0501-000398 TR-SMALL SIGNAL

Q602

0501-000398 TR-SMALL SIGNAL

Q603

0501-000398 TR-SMALL SIGNAL

ICO1

1203-000243 IC-POSI.FIXED REG.

ICO2
VA71
R103
R104
R105
R605
R606
R609
R610
R102
R608
R602
R603
R601
R101
R607
C107
C108
C102
C104
C106
CR71

1203-000429
1405-000154
2001-000429
2001-000429
2001-000429
2001-000429
2001-000429
2001-000429
2001-000429
2001-000591
2001-000734
2001-000780
2001-000780
2001-000855
2007-000290
2007-000290
2202-000128
2202-000128
2202-000780
2202-000780
2202-000780
2301-001363

XC71
C101
C103
C601
C105
BZ61
RY71
F701
F702
CN72

2301-001439
2401-000173
2401-000711
2401-002300
2401-003036
3002-001129
3501-001268
3601-000263
3601-001209
3711-000262

IC-POSI.FIXED REG.
VARISTOR
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CHIP
R-CHIP
C-CERAMIC,MLC-AXIAL
C-CERAMIC,MLC-AXIAL
C-CERAMIC,MLC-AXIAL
C-CERAMIC,MLC-AXIAL
C-CERAMIC,MLC-AXIAL
C-FILM,LEAD-PPF

J1

C-FILM,LEAD-PPF
C-AL
C-AL
C-AL
C-AL
BUZZER-PIEZO
RELAY-POWER
FUSE-CARTRIDGE
FUSE-RADIAL LEAD
HEADER-BOARD TO
CABLE
3711-003845 HEADER-BOARD TO
CABLE
3812-001283 WIRE-NO SHEATH CU

J2

3812-001283 WIRE-NO SHEATH CU

J3

3812-001283 WIRE-NO SHEATH CU

J4

3812-001283 WIRE-NO SHEATH CU

CN73

3-32

Specification

QTY

SA/SNA Remark

1N4007,1KV,1A,DO-41,TP
1N4007,1KV,1A,DO-41,TP
1N4007,1KV,1A,DO-41,TP
1N4007,1KV,1A,DO-41,TP
1N4007,1KV,1A,DO-41,TP
KSA733,PNP,250mW,TO-92,TP,120-240
KSC945-Y,NPN,250mW,TO92,TP,120-240
KSC945-Y,NPN,250mW,TO92,TP,120-240
KSC945-Y,NPN,250mW,TO92,TP,120-240
KSC945-Y,NPN,250mW,TO92,TP,120-240
7812,TO-220,3P,-,PLASTIC,11.5/
12.5V,16W,0TO+125C,1A,-,ST,78L05A,TO-92,3P,-,PLASTIC,4.6/
460Vdc,2500A,17.5x7.5mm,TP
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
3.3KOHM,5%,1/8W,AA,TP,1.8X3.2MM
4.7KOHM,5%,1/8W,AA,TP,1.8X3.2MM
470OHM,5%,1/8W,AA,TP,1.8X3.2MM
470OHM,5%,1/8W,AA,TP,1.8X3.2MM
560OHM,5%,1/4W,AA,TP,2.4X6.4MM
100ohm,5%,1/8W,TP,2012
100ohm,5%,1/8W,TP,2012
10nF,+80-20%,50V,Y5V,TP,2.5x4.
10nF,+80-20%,50V,Y5V,TP,2.5x4.
100nF,+80-20%,50V,Y5V,-,3.5x19mm,100nF,+80-20%,50V,Y5V,-,3.5x19mm,100nF,+80-20%,50V,Y5V,-,3.5x19mm,2000nF,+105%,450V,BK,38x18x30mm,33
220nF,10%,275V,BK,18x10x15.8mm,15
1000uF,20%,35V,GP,TP,13x25,5
2200uF,20%,25V,GP,TP,16x25,7.5
47?F,20%,50V,GP,TP,6.3x11,5mm
100uF,20%,16V,GP,TP,5X11mm,5mm
85DB,-,-,2KHZ,12V,0.9W,25000mA,SPST,20mS,10mS
250V,3.15A,TIME-LAG,GLASS,5x20mm
250V,1A,TIME-LAG,-,8.5x8mm
1WALL,3P,1R,7.92MM,STRAIGHT,SN,
WHT
BOX,11P,1R,2mm,STRAIGHT,SN,WHT

1
1
1
1
1
1
1

SNA
SNA
SNA
SNA
SNA
SNA
SNA

SNA

SNA

SNA

SNA

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA

1
1
1
1
1
1
1
1
1
1

SNA
SNA
SNA
SNA
SNA
SNA
SA
SNA
SNA
SNA

SNA

TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,-

SNA

SNA

SNA

SNA

Samsung Electronics

Electrical Parts List

MAIN PCB : DB93-04128D(cont.)


Location No.

Code No.

Description

J5

3812-001283 WIRE-NO SHEATH CU

J6

3812-001283 WIRE-NO SHEATH CU

J7

3812-001283 WIRE-NO SHEATH CU

J8

3812-001283 WIRE-NO SHEATH CU

TR-1
TR-2
TR-3
TR-4
4-WAY
FAN(H)
FAN(L)
POWER(N)
RY-1
RY-2
RY-3
RY-4
ST11

6042-000105
6042-000105
6042-000105
6042-000105
6042-001009
6042-001009
6042-001009
6042-001009
6042-001009
6042-001009
6042-001009
6042-001009
DB26-00066A

POWER(N)

DB39-01270A CONNECT WIRE

EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
TRANS POWER

DB41-00495A PCB-POWER
F701

DB61-00924A HOLDER-FUSE
DB62-03085A HEAT SINK

Samsung Electronics

Specification
TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,ID1.6,OD2.0,L6,NI PLT,C2600BD
ID1.6,OD2.0,L6,NI PLT,C2600BD
ID1.6,OD2.0,L6,NI PLT,C2600BD
ID1.6,OD2.0,L6,NI PLT,C2600BD
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
-,WW2-VE,-,8-PIN,230V/AC,16.5V/
DC,400mA,-,50hz,-,-,-,-,-,SSEC
WW2-P/J,#1015 18 AWG,-,1P,,BLU,-,175022-1 (AMP),ST780400
(KET),TP,220V/50Hz,4mm,170mm,-,,SSEC
WW2-P/J,FR-1,ONELAYER,VERSION1,T1.6,-,-,-,-,SSEC
-,FH-51B,-,-,-,-,SSEC
-,A6063,25,15,15,-,-,SSEC

QTY

SA/SNA Remark

SNA

SNA

SNA

SNA

1
1
1
1
1
1
1
1
1
1
1
1
1

SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA

SNA

SNA

1
1

SNA
SNA

3-33

Electrical Parts List

MAIN PCB : DB93-04128E


Location No.

Code No.

Description

D101
D102
D103
D104
D105
Q601
Q101

0402-000137
0402-000137
0402-000137
0402-000137
0402-000137
0501-000303
0501-000398

DIODE-RECTIFIER
DIODE-RECTIFIER
DIODE-RECTIFIER
DIODE-RECTIFIER
DIODE-RECTIFIER
TR-SMALL SIGNAL
TR-SMALL SIGNAL

Q102

0501-000398 TR-SMALL SIGNAL

Q602

0501-000398 TR-SMALL SIGNAL

Q603

0501-000398 TR-SMALL SIGNAL

ICO1

1203-000243 IC-POSI.FIXED REG.

ICO2
VA71
R103
R104
R105
R605
R606
R609
R610
R102
R608
R602
R603
R601
R101
R607
C107
C108
C102
C104
C106
CR71

1203-000429
1405-000154
2001-000429
2001-000429
2001-000429
2001-000429
2001-000429
2001-000429
2001-000429
2001-000591
2001-000734
2001-000780
2001-000780
2001-000855
2007-000290
2007-000290
2202-000128
2202-000128
2202-000780
2202-000780
2202-000780
2301-001363

IC-POSI.FIXED REG.
VARISTOR
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CARBON
R-CHIP
R-CHIP
C-CERAMIC,MLC-AXIAL
C-CERAMIC,MLC-AXIAL
C-CERAMIC,MLC-AXIAL
C-CERAMIC,MLC-AXIAL
C-CERAMIC,MLC-AXIAL
C-FILM,LEAD-PPF

XC71
C101
C103
C601
C105
BZ61
RY72

2301-001439
2401-000173
2401-000711
2401-002300
2401-003036
3002-001129
3501-001154

C-FILM,LEAD-PPF
C-AL
C-AL
C-AL
C-AL
BUZZER-PIEZO
RELAY-MINIATURE

RY73

3501-001154 RELAY-MINIATURE

RY71
F701
F702
CN72

3501-001268
3601-000263
3601-001209
3711-000262

J1

RELAY-POWER
FUSE-CARTRIDGE
FUSE-RADIAL LEAD
HEADER-BOARD TO
CABLE
3711-003845 HEADER-BOARD TO
CABLE
3812-001283 WIRE-NO SHEATH CU

J2

3812-001283 WIRE-NO SHEATH CU

CN73

3-34

Specification

QTY

SA/SNA Remark

1N4007,1KV,1A,DO-41,TP
1N4007,1KV,1A,DO-41,TP
1N4007,1KV,1A,DO-41,TP
1N4007,1KV,1A,DO-41,TP
1N4007,1KV,1A,DO-41,TP
KSA733,PNP,250mW,TO-92,TP,120-240
KSC945-Y,NPN,250mW,TO92,TP,120-240
KSC945-Y,NPN,250mW,TO92,TP,120-240
KSC945-Y,NPN,250mW,TO92,TP,120-240
KSC945-Y,NPN,250mW,TO92,TP,120-240
7812,TO-220,3P,-,PLASTIC,11.5/
12.5V,16W,0TO+125C,1A,-,ST,78L05A,TO-92,3P,-,PLASTIC,4.6/
460Vdc,2500A,17.5x7.5mm,TP
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
1KOHM,5%,1/8W,AA,TP,1.8X3.2MM
3.3KOHM,5%,1/8W,AA,TP,1.8X3.2MM
4.7KOHM,5%,1/8W,AA,TP,1.8X3.2MM
470OHM,5%,1/8W,AA,TP,1.8X3.2MM
470OHM,5%,1/8W,AA,TP,1.8X3.2MM
560OHM,5%,1/4W,AA,TP,2.4X6.4MM
100ohm,5%,1/8W,TP,2012
100ohm,5%,1/8W,TP,2012
10nF,+80-20%,50V,Y5V,TP,2.5x4.
10nF,+80-20%,50V,Y5V,TP,2.5x4.
100nF,+80-20%,50V,Y5V,-,3.5x19mm,100nF,+80-20%,50V,Y5V,-,3.5x19mm,100nF,+80-20%,50V,Y5V,-,3.5x19mm,2000nF,+105%,450V,BK,38x18x30mm,33
220nF,10%,275V,BK,18x10x15.8mm,15
1000uF,20%,35V,GP,TP,13x25,5
2200uF,20%,25V,GP,TP,16x25,7.5
47?F,20%,50V,GP,TP,6.3x11,5mm
100uF,20%,16V,GP,TP,5X11mm,5mm
85DB,-,-,2KHZ,12Vdc,200mW,3000mA,1FormA,10mS,
10mS
12Vdc,200mW,3000mA,1FormA,10mS,
10mS
12V,0.9W,25000mA,SPST,20mS,10mS
250V,3.15A,TIME-LAG,GLASS,5x20mm
250V,1A,TIME-LAG,-,8.5x8mm
1WALL,3P,1R,7.92MM,STRAIGHT,SN,
WHT
BOX,11P,1R,2mm,STRAIGHT,SN,WHT

1
1
1
1
1
1
1

SNA
SNA
SNA
SNA
SNA
SNA
SNA

SNA

SNA

SNA

SNA

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA

1
1
1
1
1
1
1

SNA
SNA
SNA
SNA
SNA
SNA
SA

SA

1
1
1
1

SA
SNA
SNA
SNA

SNA

TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,-

SNA

SNA

Samsung Electronics

Electrical Parts List

MAIN PCB : DB93-04128E(cont.)


Location No.

Code No.

Description

J3

3812-001283 WIRE-NO SHEATH CU

J4

3812-001283 WIRE-NO SHEATH CU

J5

3812-001283 WIRE-NO SHEATH CU

J6

3812-001283 WIRE-NO SHEATH CU

J7

3812-001283 WIRE-NO SHEATH CU

J8

3812-001283 WIRE-NO SHEATH CU

TR-1
TR-2
TR-3
TR-4
4-WAY
FAN(H)
FAN(L)
POWER(N)
RY-1
RY-2
RY-3
RY-4
ST11

6042-000105
6042-000105
6042-000105
6042-000105
6042-001009
6042-001009
6042-001009
6042-001009
6042-001009
6042-001009
6042-001009
6042-001009
DB26-00066A

POWER(N)

DB39-01270A CONNECT WIRE

FAN(H)

DB39-01270B CONNECT WIRE

4-WAY

DB39-01270C CONNECT WIRE

EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
EYELET
TRANS POWER

DB41-00495A PCB-POWER
F701

DB61-00924A HOLDER-FUSE
DB62-03085A HEAT SINK

Samsung Electronics

Specification
TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,TCWA,300V,52mm(TAPING),1/
0.6mm,-,ID1.6,OD2.0,L6,NI PLT,C2600BD
ID1.6,OD2.0,L6,NI PLT,C2600BD
ID1.6,OD2.0,L6,NI PLT,C2600BD
ID1.6,OD2.0,L6,NI PLT,C2600BD
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
ID1.8,OD2.2,L3,-,BRASS
-,WW2-VE,-,8-PIN,230V/AC,16.5V/
DC,400mA,-,50hz,-,-,-,-,-,SSEC
WW2-P/J,#1015 18 AWG,-,1P,,BLU,-,175022-1 (AMP),ST780400
(KET),TP,220V/50Hz,4mm,170mm,-,,SSEC
WW2-P/J,#1015 18 AWG,-,1P,,PINK,-,175022-1 (AMP),ST780400
(KET),TP,220V/50Hz,4mm,170mm,-,,SSEC
WW2-P/J,#1015 18 AWG,-,1P,,BLK,-,175022-1 (AMP),ST780400
(KET),TP,220V/50Hz,4mm,170mm,-,,SSEC
WW2-P/J,FR-1,ONELAYER,VERSION1,T1.6,-,-,-,-,SSEC
-,FH-51B,-,-,-,-,SSEC
-,A6063,25,15,15,-,-,SSEC

QTY

SA/SNA Remark

SNA

SNA

SNA

SNA

SNA

SNA

1
1
1
1
1
1
1
1
1
1
1
1
1

SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA

SNA

SNA

SNA

SNA

1
1

SNA
SNA

3-35

Electrical Parts List

MAIN PCB : DB93-04181A


Location No.
D901
Q401
Q901
Q902
IC05
IC06
TURBO1
OPERATION1
TIMER1
RM01
IC07
R-OPTION3
R-OPTION4
R903
R301
R401
R403
R409
R501
R404
R405
R902
R901
R406
R407
R402
R905
R906
R909
R910
C301
C402
C403
C501
C503
C504
C901
C904
C905
C907
C401
C903
C902
C906
C909
X501
SWO1
CN61
CN43
CN44

3-36

Code No.

Description

0401-000133 DIODE-SWITCHING
0501-000534 TR-SMALL SIGNAL

Specification

RLS4148,75V,150mA,LL-34,TP
2SC2412K,NPN,200mW,SOT23,TP,180-390
0504-000001 TR-DIGITAL
DTA114EKA,PNP,200mW,10K/
10K,SOT-23,TP
0504-000001 TR-DIGITAL
DTA114EKA,PNP,200mW,10K/
10K,SOT-23,TP
0506-000175 TR-ARRAY
2003,NPN,7,1W,SOP-16,ST,1000
0506-000175 TR-ARRAY
2003,NPN,7,1W,SOP-16,ST,1000
0601-000360 LED
ROUND,RED,3mm,635nm,3.2x4.5mm
0601-001375 LED
ROUND,GRN,3mm,570nm,3.8x5.3mm
0601-001375 LED
ROUND,GRN,3mm,570nm,3.8x5.3mm
0609-001204 Module Remocon
HORIZONTAL,6.5mm,TR
1103-001016 IC-EEPROM
93C56,256x8/
128x16Bit,SOP,8P,5x4mm,-,2.7/5.5V,-,-,40to+85C,10uA,-,TP
2007-000029 R-CHIP
0ohm,5%,1/8W,TP,2012
2007-000029 R-CHIP
0ohm,5%,1/8W,TP,2012
2007-000300 R-CHIP
10Kohm,5%,1/8W,TP,2012
2007-000468 R-CHIP
1Kohm,5%,1/8W,TP,2012
2007-000468 R-CHIP
1Kohm,5%,1/8W,TP,2012
2007-000468 R-CHIP
1Kohm,5%,1/8W,TP,2012
2007-000468 R-CHIP
1Kohm,5%,1/8W,TP,2012
2007-000477 R-CHIP
1Mohm,5%,1/8W,TP,2012
2007-000766 R-CHIP
330ohm,5%,1/8W,TP,2012
2007-000766 R-CHIP
330ohm,5%,1/8W,TP,2012
2007-000872 R-CHIP
4.7Kohm,5%,1/8W,TP,2012
2007-000947 R-CHIP
47ohm,5%,1/8W,TP,2012
2007-001067 R-CHIP
6.8Kohm,1%,1/8W,TP,2012
2007-001067 R-CHIP
6.8Kohm,1%,1/8W,TP,2012
2007-001071 R-CHIP
6.8Kohm,5%,1/8W,TP,2012
2007-001318 R-CHIP
1Kohm,5%,1/4W,TP,3216
2007-001318 R-CHIP
1Kohm,5%,1/4W,TP,3216
2007-001318 R-CHIP
1Kohm,5%,1/4W,TP,3216
2007-001318 R-CHIP
1Kohm,5%,1/4W,TP,3216
2203-000192 C-CER,CHIP
100nF,+80-20%,50V,Y5V,2012
2203-000192 C-CER,CHIP
100nF,+80-20%,50V,Y5V,2012
2203-000192 C-CER,CHIP
100nF,+80-20%,50V,Y5V,2012
2203-000192 C-CER,CHIP
100nF,+80-20%,50V,Y5V,2012
2203-000192 C-CER,CHIP
100nF,+80-20%,50V,Y5V,2012
2203-000192 C-CER,CHIP
100nF,+80-20%,50V,Y5V,2012
2203-000192 C-CER,CHIP
100nF,+80-20%,50V,Y5V,2012
2203-000192 C-CER,CHIP
100nF,+80-20%,50V,Y5V,2012
2203-000192 C-CER,CHIP
100nF,+80-20%,50V,Y5V,2012
2203-000192 C-CER,CHIP
100nF,+80-20%,50V,Y5V,2012
2203-000260 C-CER,CHIP
10nF,10%,50V,X7R,2012
2203-000260 C-CER,CHIP
10nF,10%,50V,X7R,2012
2203-000444 C-CER,CHIP
1nF,10%,50V,X7R,2012
2203-000444 C-CER,CHIP
1nF,10%,50V,X7R,2012
2401-003107 C-AL
47uF,20%,16V,GP,TP,5x7,5
2802-001198 RESONATOR-CERAMIC 10MHZ,0.5%,BK,8X3X5.5MM
3404-001220 SWITCH-TACT
12V,50mA,160gf,6.1x6.1x5.0mm,SPST
BOX,5P,1R,2.5MM,ANGLE,SN,WHT
3711-000992 HEADER-BOARD TO
CABLE
BOX,4P,1R,2mm,ANGLE,SN,NTR
3711-004067 HEADER-BOARD TO
CABLE
BOX,3P,1R,2.5MM,ANGLE,TIN,BLU
3711-005319 HEADER-BOARD TO
CABLE

QTY

SA/SNA Remark

1
1

SNA
SNA

SNA

SNA

1
1
1
1
1
1
1

SNA
SNA
SNA
SNA
SNA
SNA
SNA

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA
SNA

SNA

SNA

Samsung Electronics

Electrical Parts List

MAIN PCB : DB93-04181A(cont.)


Location No.
IC04

Code No.

Description

DB09-00516A IC MICOM

DB41-00510A PCB-MAIN
CN02

DB93-04187A ASSY-CONNECT WIRE

Samsung Electronics

Specification
S3C848AXZZ-QT8A,,64P,+5V,10MHz,STM-0648-OA, ROM
Size: 48K bytes,8BIT,8BIT,QFP,QFP,,8BIT,-40~+85
WW2-P/J,FR-4,TWOLAYER,VERSION1,T1.6,65*80,-,-,,VE,SSEC
WW2,,26AWG,12-PIN,250mm

QTY

SA/SNA Remark

SA

SNA

SNA

3-37

9. Circuit Descriptions
9-1 PCB Circuit Descriptions
9-1-1 Main PCB

INDOOR TEMPERATURE SENSOR


INPUT PART
STEP MOTOR CONTROL PART
REMOTE RECEIVER PART
DISPLAY CONTROL PART
MOTOR RPM FEEDBACK

This Document can not be used without Samsung's authorization.

Samsung Electronics

9-1

PCB Circuit Descriptions

PCB Circuit Descriptions

9-1-2 Power PCB

INDOOR FAN CONTROL PART

AC/DC PART

ZERO CROSSING PART

LOAD DRIVE RELAY PART

BUZZER DRIVE PART

This Document can not be used without Samsung's authorization.

Samsung Electronics

9-2

9-2 Refrigerating Cycle Diagram

Outdoor Unit

Indoor Unit

Capillary tube
T1

2 way valve

Note
Check valve

Liquid side

Heat
Exchanger
(Condenser)

Cross Fan

Heat
Exchanger
(Evaporator)

Propeller Fan

Capillary tube

T2
Gas side
3 way valve

4 way valve

Cooling
Compressor

9-4

Heating
Gas Leak Check Point

Samsung Electronics

11. Operating Instructions


11-1 Name of Each Part
11-1-1 Indoor Unit
The design and shape are subject to change according to the model.

Air Inlet

Temperature sensor

Power(On/Off) button
Air lter
(under the grille)

Air ow blades
(outlet)

Operation indicator
(GREEN)
Timer indicator
(GREEN)
Turbo indicator
(RED)
Power(On/Off) button

11-1

Samsung Electronics

11-1-2 Outdoor Unit

H/P
Air Inlet(Rear)

Air Outlet

Connection Valve

C/O
Air Inlet(Rear)

Air Outlet

Connection Valve

Samsung Electronics

11-2

11-2 Main Function


11-2-1 Basic Function
Mode

Explanation

Auto Mode

Press the

button on the remote control until

Cool Mode

Press the

button on the remote control until

Press the
is displayed.

is displayed.

is displayed.

button to select the fan speed until the required setting

Automatic (rotated :
Low
Medium
High
Maximum

11-3

Remark

Dry Mode

Press the

button on the remote control until

is displayed.

Fan Mode

Press the

button on the remote control until

is displayed.

Samsung Electronics

Operating Instructions

11-2-2 Applied Function


Mode
Turbo Function

Explanation
Press the

Remark

button.

After 30 minutes, the air conditioner is reset automatically to the


previous setting.

You can select the Turbo function in the Auto, Cool and Heat mode.
If you select this function in the Dry or Fan mode, the mode
changes to the Auto mode.

Samsung Electronics

11-4

11-3 Wireless Remote Control-Buttons and Display

Remote control
transmission indicator
Operating mode
AUTO, COOL, DRY,
FAN, HEAT)
Temperature setting

Turbo mode
Good Morning mode
Fan speed
Air ow direction
On Timer setting
Off Timer setting

Mode selection button


(AUTO, COOL, DRY,
FAN, HEAT)
Temperature adjustment
buttons
Turbo button
Fan speed adjustment
button
Swing button
On Timer button
Off Timer button

Battery discharge indicator


Good Morning button

11-5

On/Off &
Timer Set/Cancel button

Samsung Electronics

14. Reference Sheet


14-1 Index for Model Name
Private Expert Model for Split Type and Europe Type

Model Code

Model name

18

Product
Cooling Only

AS

Heat Pump

AQ

Inverter
Inverter

14-1

Capacity
Btu

Project

Serial Version

BIG

New

Forte

1st VE Model

GP

2nd VE Model

HB

WW Premium

Moderato

Neo Classic

Deluxe Classic

Presto

Tiffany

Vivace

WW

Tsar

Buyer Code
MIDDLE EAST

MID

RUSSIA

SER

Samsung Electronics

14-2 Refrigerant Pressure during the Charging


Outdoor Unit Temperature

Low Pressure kg/cm2(PSIC)

Less than 20C

4.5 ~ 4.7(64~67)

Less than 24C

4.7 ~ 4.8(67~68)

Less than 28C

4.8 ~ 4.9(68~70)

Less than 32C

4.9 ~ 5.0(70~71)

Less than 36C

5.0 ~ 5.1(71~73)

Less than 40C

5.1 ~ 5.2 (73~74)

Less than 44C

5.2 ~ 5.3 (74~75)

14-3 Pressure & Capacity mark


Power/Heat
W

cal/s

kcal/h

Btu/h

HP

kg.m/s

lbm/s

0.23885

0.85985

3.4121

0.001341

0.10197

0.73756

4.1868

3.6

14.286

0.0056146

0.42693

3.088

1.163

0.27778

3.9683

0.0015596

0.11859

0.85778

0.29307

0.06999

0.252

3.9302x10

0.029885

0.21616

745.7

178.11

641.19

2,544.4

76.04

550

9.8067

2.3423

8.4322

33.462

0.013151

7.233

1.3558

0.32383

1.1658

4.6262

0.0018182

0.13826

Samsung Electronics

-4

14-2

14-4 Q & A for Non-trouble


Classification

Cooling

Class
Q

The cooling is weak.

When it is hot outside, its cooling capacity decreases due to the increase of the ambient temperature.
When the dust filter gets blocked or warm outside air gets in, the cooling capacity will decrease. So,
make sure to clean the dust filter frequently, prevent heat loss by closing the doors and insulate the
cooling area by using curtains, blinds, shades or window tinting.

The cooling is good generally. But, it gets weak when it is considerably hot.

It occurs when the outdoor unit is exposed to direct sun light and heat-up air is not ventilated well.
So, set up a sunblind over the outdoor unit and keep stuff away from the unit to increase the ventilation.
When the cooling capacity decreases during a heat wave, clean the heat exchanger of the outdoor unit or
spray some cold water to the heat exchanger to increase the cooling capability.

The cooling is weak. Does it need refrigerant charging?

It is not correct charging refrigerant regularly. Except that you have moved in several times or the
connection pipes are broken, the refrigerant does not run low. So, when refrigerant is additionally
charged, it could be costly and cause a product's failure. When the refrigerant leaks, all of it will escape
in a short time resulting in cooling failure and no water coming out of the drain hose. So, if water comes
out from the drain hose, it indicates the normal operation of the product and it does not need refrigerant
charging.

It fails to do cooling.

When the air conditioner is set to Ventilation or the desired temperature is set higher than the current
temperature, it fails to do cooling. In this case, select Cooling or set the desired temperature lower.

It floods the floor.

Place the drain hose properly. When it is not placed properly, the drain water would flow back flooding
the floor. So, straighten out the drain hose for the water to be drained well.

Water drips at the drain connection (service valve) of the outdoor unit.

When a glass bottle is taken out of the refrigerator, moisture gets condensed on its surface due to the
temperature differences. The same principle applies to the air conditioner. When cold refrigerant goes
through the copper tube, moisture gets condensed on the surface of the tube and the connection areas.
To prevent the water condensation, the pipes are insulated. But, the connection areas of the outdoor unit
are not insulated for the purpose of maintenance or repair, and water gets condensed due to the temperature differences and drips down. Generally, it evaporates right away. But, when it drips much during
muggy days, put a water pan on the floor.

It leaks even though a drain pump is used.

It occurs when the drain pump is plugged out or it is out of order. Check the power of the drain pump
and the position of the drain hose, and when the pump is faulty, contact the drain pump manufacturer.
Samsung Electronics do not manufacture drain pumps. So, we are not able to correct the drain pump
problems.

Whenever the air conditioner is turned on, it irritates my eyes and gives me a headache.

There are no components in the air conditioner irritating the eyes and sending out chemical smells.
But, when the air conditioner is turned on, other smell sources are sucked into the air conditioner and get
out of it. So, find and root out the smell sources. Generally, it occurs at a interior renovated place,
a pharmacy, a gasoline handling place, a tire shop, a second-hand book shop or an electronic
component handling place; when its chemical or musty smells are sucked in and sent out, it can be misled
that the air conditioner generates them. So, find and root out the problem or refresh the room frequently.

Leakage

Smells

14-3

Description

Samsung Electronics

Q & A for Non-trouble(cont.)


Classification

Smells

Class

Description

Whenever the air conditioner is turned on, it stinks.

There are no components in the air conditioner sending out chemical smells. But, when the air conditioner
is turned on, other smell sources are sucked into the air conditioner and get out of it. So, find and root out
the smell sources. Generally, when the drain hose is taken out to the washing room or there are sources
of smells such as a diaper bin, a shoe shelf or a socks bin, bad smells generate. Also, it occurs where glass
cleaners or air fresheners are used; when they are sucked in interacting with dusts and moistures inside,
bad smells generate. These kinds of organic materials noxious to human bodies. So, we recommend
against the use of them.

Whenever the air conditioner is turned on, it smells sour.

When the room is papered recently, its paste smells would be sucked inside. Also, when the air conditioner is installed in the study room of young boys loving sweat-generating activities such as the basketball,
excessive sweats evaporate and get sucked into the air conditioner resulting in bad smells. So, find and
root out the problem or refresh the room frequently.

Whenever the air conditioner is turned on, it smells musty.

It is due to the improper keeping of the product after its use. When keeping the product, dry up the
inside with the operation of Ventilation to prevent must. When the product is kept without drying up the
inside with Ventilation, mold would grow inside resulting in must. So, open the windows and switch on
the Ventilation function to get rid of the saturated smell inside.

Whenever the air conditioner is turned on, it sends out bad smells such as stale smells.

It occurs generally when there are pet animals in the house. Their smells stay at the same place.
But, when the air conditioner is turned on, the air gets circulated resulting in the circulation of the smells.
So, find and root out the problem or refresh the room frequently.

It sends out bad smells.

When the air filter is filthy, it could send out bad smells. So, clean the filter and ventilate the room with
the windows open while operating the Ventilation function.

It won't start.

There is a power failure or it is plugged out. Also, check if the power distribution panel is switched off.

It goes off during operation.

When the hot air does not escape properly, it goes off during operation. It occurs when it does not
ventilate properly because the outdoor unit is covered, the back of the outdoor unit is blocked by a
cardboard or a plywood panel, and the front of the outdoor unit is blocked by the closed window or
other obstacles. Clear the above obstacles from the outdoor unit.

It generally works properly. But, when it's considerably hot, it goes off during operation.

It occurs when the outdoor unit is exposed to direct sunlight and the hot air does not escape properly.
Set up a sun blind over the outdoor unit and clear the neighboring obstacles from the outdoor unit to
provide good ventilation. When it goes off frequently during a heat wave, it would prevent the turn-off and
increase the cooling capacity cleaning the outdoor unit or spraying some water to the heat exchanger.

Operation

Samsung Electronics

14-4

Q & A for Non-trouble(cont.)


Classification

Operation

Class
Q

The remote controller won't operate.

When the batteries run out or the transmitter or receiver of the remote controller is blocked by obstacles,
change the batteries or keep the obstacles away from the controlling area. Also, the remote controller may
not work under intensive light from a 3-wave length lamp or a neon sign due to the EMI. In this case, take
the remote controller closer to the receiver.

Who installs the air conditioner? (Relocation/Re-installation)

When relocating or re-installing the air conditioner, make sure to contact Samsung Electronics Service
Center or Authorized Service Agent and have them to do the job. (If not, it could cause personal injury or
product damage.)
The cost for the relocation/re-installation of the air conditioner is subject to the customer's expense.
There is a cost table. But, our service engineer needs to visit to total up the cost correctly.
When you move in, make sure to contact Samsung Electronics Service Center or Authorized Service Agent
in advance to streamline the process.

Is it possible to install the outdoor unit outside?

It is possible to install it at a designated place in the apartment or on the rooftop nearby.


But, it's illegal hanging an angle iron case with the outdoor unit in it outside the apartment.
Also, it is illegal obstructing passers-by with the outdoor unit installed outside.

What can be done to install the outdoor unit facing the road because it is a commercial building?

The following is an excerpt from Building Code going into effect from JUNE 1st 2005. "The exhaust pipe of
a cooling or ventilation facility installed in a building adjacent to the streets of commercial or residential
areas shall be installed higher than 2m to prevent the exhaust air from blowing directly to passers-by and
the current facilities shall be corrected by MAY 31st 2005." So, please install it higher than 2m or not to blow
the hot exhausting air directly to passers-by.

What about installing a windscreen during installation not to blow hot air directly to passers-by?

When the hot air from the front of the outdoor unit is blocked, the product's performance will be
affected and it will fail to operate properly. So, keep it at least 300mm away from its surrounding walls and
give it good ventilation.

Installation

14-5

Description

Samsung Electronics

14-5 Cleaning/Filter Change


14-5-1 Cleaning Your Air Conditioner
For the best use of your air conditioner, you must clean it every 2 weeks regularly to remove the dust that accumulates on the air filter.

Before cleaning your air conditioner, ensure that you have switched off the breaker used for the unit.

1. Slide the lower front grille down.


2. Slide the upper front grille up slightly, then open the grille by pulling right
and left sides of the grille.
3. Disassemble the upper front grille by opening the grille completely.
4. Lift out the bottom edge of the air filters and pull down to release them.
5. Remove all dust on the air filters with a vacuum cleaner or brush.
6. When you have finished, insert the top part of the filters into their slot
and push down on the bottom edge until they click into place.

Front grille
Air lter

7. Clean the front grille with a damp cloth and mild detergent
(do NOT use benzene, solvents or other chemicals).
8. Fix the left side of grille support, then insert the right side of grille support.

Body groove
Body

Front grille
Hook
Body

Note : If you have not used the air conditioner for a long period of time, set the fan
going for three to four hours to dry the inside of the air conditioner thoroughly.
To close the upper front grille completely after cleaning filters, turn on and turn off the air conditioner.

Samsung Electronics

14-6

Reference Sheet

14-5-2 Cleaning Deodorizing and Bio Filters (Option)


To remove minute dust particles and odors, deodorizing and Bio filters are installed in the air conditioner.
You should clean the filters every 3 months.
1. Open the upper front grille by pulling right and left sides of the grille.

Deodorizing Filter

2. Pull out the deodorizing and Bio filters.


3. Wash the filters with clean water, then dry them in the shade.
4. Insert the filters into the original position.
Note : You can change the position of filters with each other.

Bio Filter

5. Close the front grille.

14-7

Samsung Electronics

14-6 Installation
14-6-1 Before Installation
Keep the air conditioner outlet and inlet free from its surroundings.
In case of installation, keep the symmetry and fix it to prevent vibration.
The pipe length shall meet the standard as far as possible.

14-6-2 Installation Procedure


Location
Install the product in an area to guarantee the best cooling effect, convenience of piping and electric work, and inexistence of
vibration or wind.

Wall Drilling
Drill the wall downward in a diameter of 60 to 65mm.

Fixing Indoor Unit & Outdoor Unit


Fix the air conditioner indoor unit securely to the wall. Secure the outdoor unit in a suitable position.

Pipe Spooling & Connecting


You shall cut the pipe with a pipe cutter and grind all the burrs of the cut surface.
Pipe expansion may continue until the pipe surface becomes uneven or torn apart.
Be sure to use a torque wrench to tighten pipes or flare nuts.
<Torque & Depth>
Outer Diameter(D)

Torque(kgfcm)

Depth(A)

6.35mm(1/4")

140~170

1.3mm

9.52mm(3/8")

250~280

1.8mm

12.70mm(1/2")

380~420

2.0mm

15.88mm(5/8")

440~480

2.2mm

19.05mm(3/4")

990~1,210

2.2mm

D
A

Leak Test
Put an inert gas like nitrogen in the outdoor unit pipe and put soap bubbles or other test liquids on the pipe surface for the
leak test.

Drain Hose Connecting


Install the drain hose downward to drain water naturally. Be sure to pour water into the hose to check if it drains well.

Electric & Earth Work


Electric and earth work shall meet the "Electric Facility Technology Standard" and the "Internal Wire Regulation" of the Electric
Business Laws.

Inspection & Trial Run


Upon completion of the tests, you shall make a trial run while you explain the main functions of the air conditioner to finish the
installation.

Samsung Electronics

14-8

14-7 Installation Diagram of Indoor Unit and Outdoor Unit


14-7-1 Air-Purge Procedure
1) Connect each assembly pipe to the appropriate valve on
the outdoor unit and tighten the flare nut.

Indoor unit

Outdoor unit

Gas pipe side

Liquid pipe side D

2) Connect the charging hose of low pressure side of


manifold gauge to the packed valve having a
service port (3/8" Packed valve) as shown at the
figure.

3) Open the valve of the low pressure side of manifold


gauge counter-clockwise.

4) Purge the air from the system using vacuum pump for
about 30 minutes.
- After that, please recheck that pressure is stabilized.
- Close the valve of the low pressure side of manifold
gauge clockwise.
- Remove the hose of the low pressure side
of manifold gauge.

5) Set valve cork of both liquid side and gas side of packed
valve to the open position.

6) Mount the valve stem nuts to the 2 way and


3 way valve. And mount the service port cap to
3 way valve.

Vacuum Pump

Valve stem

Stem cap

7) Check for gas leakage.


- At this time, especially check for gas
leakage from the 3 way valve's stem nuts,
and from the service port cap.

A
(gas)

B
(liquid)

14-9

Samsung Electronics

Reference Sheet

14-7-2 "Pump down" Procedure


Pump down will be carried out when an evaporator is replaced or when the unit is relocated in another area.

1) Remove the caps from the 3 way valve and the


3 way valve.

2) Turn the 3 way valve clockwise to close and


connect a pressure gauge (low pressure side)
to the service valve, and open the 3 way valve
again.

3 way Valve

2 way Valve

3) Set the unit to cool operation mode.


(Check if the compressor is operating.)

4) Turn the 3 way valve clockwise to close.

5) When the pressure gauge indicates "0" turn the


3 way valve clockwise to close.

6) Stop operation of the air conditioner.

7) Close the cap of each valve.

Relocation of the air conditioner


Refer to this procedure when the unit is relocated.
Carry out the pump down procedure (refer to the details of pump down).
Remove the power cord.
Disconnect the assembly cable from the indoor and outdoor units.
Remove the flare nut connecting the indoor unit and the pipe.
At this time, cover the pipe of the indoor unit and the other pipe using a cap or vinyl plug to avoid foreign material
entering.
Disconnect the pipe connected to the outdoor unit.
At this time, cover the valve of the outdoor unit and the other pipe using a cap or vinyl plug to avoid foreign
material entering.
Make sure you do not bend the connection pipes in the middle and store together with the cables.
Move the indoor and outdoor units to a new location.
Remove the mounting plate for the indoor unit and move it to a new location.

Samsung Electronics

14-10

ELECTRONICS

This Service Manual is a property of Samsung Electronics Co., Ltd.


Any unauthorized use of Manual can be punished under applicable
International and/or domestic law.

Samsung Electronics Co., Ltd. Sep. 2006.


Printed in China.
Code No. DB98-00000A(1)

1. Precautions
1-1 Installing the air conditioner
Users should not install the air conditioner by themselves.
Ask the dealer or authorized company to install the air conditioner except the window-type air conditioner in U.S.A and Canada.
If you dont install the air conditioner properly, it may cause a fire, a water leakage or an electric shock.
You must install the air conditioner according to the national wiring regulations and safety regulations.
Install the indoor unit higher than 2.5m from the floor to avoid the injury caused by the operation of the fan.
(except the window-type air conditioner)
The manufacturer is not responsible for any accidents or injury caused by an incorrect installation.
When installing the built-in type air conditioner, keep all electric cables such as the power cable and the connection cord in pipes,
ducts, or cable channels to protect them from the danger of impact or any other incidents.

1-2 Power supply and circuit breaker


If the power cord of the air conditioner is damaged, it must be replaced by the manufacturer or a qualified person in order to avoid
a hazard.
The air conditioner must be plugged into an independent circuit if applicable or connect the power cable to the auxiliary circuit
breaker.
An all pole disconnection from the power supply must be incorporated in the fixed wiring with a contact opening of >3mm.
Do not extend an electric cord to the air conditioner.
The air conditioner must be plugged in after you complete the installation.

1-3 During operation


Do not repair the air conditioner at your discretion.
It is recommended to contact a service center directly.
Never spill any kind of liquid on the air conditioner.
If this happens, turn off the air conditioner and contact an authorized service center.
Do not insert anything between the airflow blades to prevent damage of the inner fan and consequent injury.
Keep children away from the air conditioner.
Do not place any obstacles in front of the air conditioner.
Do not spray any kind of liquid into the indoor unit. If this happens, turn off the air conditioner and contact a service center.
Make sure that the air conditioner is well ventilated at all times:
Do not place a cloth or other materials over it.
Remove the batteries if you dont use the remote control for a long time. (If applicable)
Use the remote control within 7 meters from the indoor unit. (If applicable)

Samsung Electronics

1-1

1-4 Disposing of the unit


Before throwing out the air conditioner, remove the batteries from the remote control.
When you dispose of the air conditioner, consult your dealer. If pipes are removed incorrectly, refrigerant may blow out and cause
air pollution. When it contacts with your skin, it can cause skin injury.
The package of the air conditioner should be recycled or disposed of properly for environmental reasons.

1-5 Others

1-2

Never store or load the air conditioner upside down or sideways to prevent the damage to the compressor.
Young children or infirm persons should be always supervised when they use the air conditioner.
Max current is measured according to IEC standard for safety.
Current is measured according to ISO standard for energy efficiency.

Samsung Electronics