Troubleshooting When Service Code
Troubleshooting When Service Code
Fuse No.
Fuse capacity
Destination of power
Engine throttle and pump controller (Controller power supply)
10A
Switch power
supply
(Fusible link:
A34)
Switch power
supply
(Fusible link:
A34)
Switch power
supply
(Fusible link:
A34)
Constant power
supply
(Fusible link:
A35)
20-266
(11)
20A
10A
10A
10A
Horn switch
10A
(Spare)
10A
10A
10A
10
10A
(Spare)
11
20A
12
20A
13
20A
Light switch
14
10A
15
10A
16
10A
17
20A
Monitor panel
18
10A
Starting switch
19
10A
Room lamp
20
10A
(Spare)
Travel alarm
DC/DC converter
Radio
Air conditioner unit
PC200/220(LC)-7
TROUBLESHOOTING
Problems which occur when controller power supply of engine throttle and pump controller is defective
a The controller power supply (FB1-1) of the engine throttle and pump controller drives the controller system.
a Accordingly, if the controller power supply is turned off, the controller cannot control the governor motor and
battery relay and the following problems occur.
1) The engine can be started but cannot be stopped.
2) The engine speed cannot be controlled with the fuel control dial.
a If the above problems occur, check the related fuse (FB1-1) and "green LED" of the engine throttle and pump
controller to see if the power is supplied normally.
Lighting: The controller power is supplied (There is not an error and the power supply is normal).
Flashing: The controller power is supplied (There is an error).
Put out: The controller power is not supplied.
PC200/220(LC)-7
20-267
(5)
TROUBLESHOOTING
Problems which occur when solenoid power supply of engine throttle and pump controller is defective
a The solenoid power supply (FB1-2) of the engine throttle and pump controller is used by the controller to drive
the solenoids and relays.
a Accordingly, if the solenoid power supply is turned off, when the controller outputs the power to the solenoids
or relays, the power is not supplied to any of the solenoids and relays and all or some of the following error
codes are displayed simultaneously.
[E212]: Disconnection in travel junction solenoid
[E213]: Disconnection in swing holding brake solenoid
[E214]: Disconnection in pump merge-divider solenoid
[E215]: Disconnection in 2-stage relief solenoid
[E216]: Disconnection in travel speed shifting solenoid
[E223]: Disconnection in LS-EPC solenoid
[E233]: Disconnection in PC-EPC solenoid
[E248]: Disconnection in attachment flow rate adjustment EPC solenoid (when attachment is installed)
a If the above problems occur, check the related fuse (FB1-2) and inlet voltage of the engine throttle and pump
controller.
1) Disconnect connector C03 of the controller and connect a T-adapter to the wiring harness side.
2) Turn the starting switch ON.
3) Measure the voltage between each of pins (2) and (12) and each of pins (31), (32), and (33).
Pins (2) and (3) are the power supply pins and pins (31), (32), and (33) are the ground pins.
If the voltage is 20 30 V, it is normal.
20-268
(5)
PC200/220(LC)-7
PC200/220(LC)-7
20-301
(5)
TROUBLESHOOTING
Service Code in Electrical System E317 (Disconnection in governor motor Phase A and B) .................... 20-372
Service Code in Electrical System E318 (Short-circuiting in governor motor Phase A and Phase B) ....... 20-374
Service Code in Electrical System E501 ("Model Selection" function not provided yet) ............................ 20-376
Service Mode in Electrical System E502 (Model selecting signal fault) ..................................................... 20-377
Failure Code in Mechanical System A000N1 (Out-of-rate engine rotation at high idle) ............................. 20-378
Failure Code in Mechanical System A000N2 (Out-of-rate engine rotation at low idle) .............................. 20-378
Failure Code in Mechanical System AA10NX (Air cleaner clogging) ......................................................... 20-379
Failure Code in Mechanical System AB00KE (Abnormally lowered charging voltage).............................. 20-380
Failure Code in Mechanical System B@BAZG (Abnormally lowered engine oil pressure) ........................ 20-382
Failure Code in Mechanical System B@BAZK (Abnormally lowered engine oil level)............................... 20-383
Failure Code in Mechanical System B@BCNS (Engine coolant overheating) ........................................... 20-384
Failure Code in Mechanical System B@BCZK (Abnormally lowered radiator coolant level) ..................... 20-385
Failure Code in Mechanical System B@HANS (Hydraulic oil overheating)................................................ 20-386
20-302
(11)
PC200/220(LC)-7
Service Code
Failure Code
Display in
monitor panel
Display in
monitor panel
Display in
monitor panel
Failure
phenomenon
Failure content
Response from
monitor panel
or controller
Action taken by the monitor panel or controller to protect an affected system or equipment, when they
detect some failure.
Phenomenon
occurring on
machine
Phenomenon that occurs on the machine, resulting from the above action taken by the monitor panel or
controller
Relative
information
20-304
PC200/220(LC)-7
TROUBLESHOOTING
This is part of the electrical circuit diagram which shows the portion where the failure occurred.
Connector No.: Indicates (Type - numbers of a pin) (color)
Arrow: Roughly indicates the location in the machine where it is installed.
PC200/220(LC)-7
20-305
(1)
TROUBLESHOOTING
E101
Service Code
Failure Code
E101
DAF0KT
Failure
phenomenon
Failure content
The voltage in the firm power source circuit for Monitor Panel (battery) has dropped below 12 V or
exceeded 36 V.
Response from
Monitor Panel
None in particular
Phenomenon
occurring on
machine
A display for information on the failure history (in the electrical system) cannot be called.
Cause
Disconnection of wiring
harness
3
(Disconnection or
connector contact fault)
Resistance
value
Below 1 z
Resistance
value
Below 1 z
Resistance
value
Below 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
for the troubleshooting.
Grounding fault of wiring
harness
4
(Contact with grounding
circuit)
20-306
(5)
Resistance
value
Above
1 Mz
Resistance
value
Above
1 Mz
Resistance
value
Above
1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
for the troubleshooting.
C03
Voltage
20 30 V
PC200/220(LC)-7
E101
PC200/220(LC)-7
20-307
E112
Service Code
Failure Code
E112
DY2DKB
Failure
phenomenon
Short-circuiting in normal rotation system of windshield wiper motor drive (in monitor panel system)
Failure content
Abnormal current flew to the windshield wiper motor normal rotation circuit, when power is provided.
Response from
Monitor Panel
Power supply to the windshield wiper motor normal rotation circuit is turned OFF.
Phenomenon
occurring on
machine
Cause
Windshield wiper motor
defective
1
(Internal short-circuiting
or grounding fault)
and
Above 1 M
and grounding
Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
for the troubleshooting.
Between wiring harness between P01 (female)
W04 (male)
and grounding
and
Resistance
value
Above 1 M
Turn the engine starting switch OFF for the preparations, and hold it in the ON position
for the troubleshooting.
P01
20-308
Between
and grounding
Voltage
OFF
Below 3 V
ON
Below 3 V20 30 V
(at constant cycle)
PC200/220(LC)-7
E112
PC200/220(LC)-7
20-309
E113
Service Code
Failure Code
E113
DY2EKB
Failure
phenomenon
Short-circuiting in reverse rotation system of windshield wiper motor drive (in Monitor Panel system)
Failure content
Abnormal current flew to the reverse rotation circuit of the windshield wiper motor drive, when the
windshield wiper was set in motion.
Response from
Monitor Panel
Power supply to the reverse rotation circuit of the windshield wiper motor drive was switched OFF.
Phenomenon
occurring on
machine
Cause
Windshield wiper motor
defective
1
(Internal short-circuiting
or grounding fault)
and
Above 1 M
and grounding
Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
for the troubleshooting.
Between wiring harness between P01 (female)
W04 (male)
and grounding
and
Resistance
value
Above 1 M
Turn the engine starting switch OFF for the preparations, and hold it in the ON position
for the troubleshooting.
P01
20-310
Between
and grounding
Voltage
OFF
Below 3 V
ON
Below 3 V20 30 V
(at constant cycle)
PC200/220(LC)-7
TROUBLESHOOTING
E113
PC200/220(LC)-7
20-311
(1)
TROUBLESHOOTING
E114
Service Code
Failure Code
E114
DY2CKB
Failure
phenomenon
Abnormal current flew to the window washer drive circuit, when the circuit was grounded and power was
switched ON.
Response from
Monitor Panel
Power supply to the grounding in the window washer motor circuit was switched OFF.
Phenomenon
occurring on
machine
Failure content
Cause
Window washer drive
1 motor defective
(Internal short-circuiting)
Short-circuiting of wiring
harness
2
(Contact with 24 V
circuit)
Resistance value
5 20 z
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
for the troubleshooting.
Between wiring harness from P01 (female) (3) to J04 to
A50 (female) (2) and grounding, or between wiring harness between P01 (female) (3) and D04 (female) (8) and
grounding
Voltage
Below 1 V
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
for the troubleshooting.
3 Monitor panel defective
20-312
(7)
P01
Between (3) and grounding
Voltage
OFF
20 30 V
ON
Below 1 V
PC200/220(LC)-7
TROUBLESHOOTING
E114
PC200/220(LC)-7
20-313
(1)
TROUBLESHOOTING
E114
Service Code
Failure Code
E114
DY2CKB
Failure
phenomenon
Abnormal current flew to the window washer drive circuit, when the circuit was grounded and power was
switched ON.
Response from
Monitor Panel
Power supply to the grounding in the window washer motor circuit was switched OFF.
Phenomenon
occurring on
machine
Failure content
Cause
Window washer drive
1 motor defective
(Internal short-circuiting)
Short-circuiting of wiring
harness
2
(Contact with 24 V
circuit)
Resistance value
5 20 z
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
for the troubleshooting.
Between wiring harness from P01 (female) (3) to J04 to
A50 (female) (2) and grounding, or between wiring harness between P01 (female) (3) and D02 (female) (7) and
grounding
Voltage
Below 1 V
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
for the troubleshooting.
3 Monitor panel defective
20-313-1
(11)
P01
Between (3) and grounding
Voltage
OFF
20 30 V
ON
Below 1 V
PC200/220(LC)-7
TROUBLESHOOTING
E114
PC200/220(LC)-7
20-313-2
(5)
TROUBLESHOOTING
E115
Service Code
Failure Code
E115
DY20KA
Failure
phenomenon
Failure content
Response from
Monitor Panel
Phenomenon
occurring on
machine
Relative
information
Input of W signal at both ends of movement (ON or OFF) can be confirmed in the monitor function.
(Code No. 049: Monitor input 3)
Cause
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position for the troubleshooting.
Windshield wiper motor
1 defective
(Internal disconnection)
Disconnection of wiring
harness
2
(Disconnection or faulty
contact with connector)
W04 (female)
Resistance value
Below 1 z
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position for the troubleshooting.
Wiring harness between P01 (female) (5) and W04 (male)
(6)
Resistance
value
Below 1 z
Resistance
value
Below 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
for the troubleshooting.
P01
3 Monitor panel defective
Between (5) and grounding
20-314
(5)
Voltage
Below 1 V
20 30 V
PC200/220(LC)-7
E115
PC200/220(LC)-7
20-315
E116
Service Code
Failure Code
E116
DY20MA
Failure
phenomenon
Failure content
P signal in the retraction range is not inputted, when the wiper is retracted.
Response from
Monitor Panel
Power supply to the windshield wiper motor is switched OFF, when the wiper is
retracted.
Phenomenon
occurring on
machine
Relative
information
It can be checked in the monitoring function whether P signal (ON or OFF) in the retraction operation
range is inputted or not. (Code No. 049: Monitor Input 3)
Cause
Windshield wiper motor
1 defective
(Internal disconnection)
Disconnection of wiring
harness
2 (Disconnection or defective contact with connector)
and
Resistance value
Retraction range
Below 1
Operation range
Above 1 M
Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
Wiring harness between P01 (female)
and grounding
Resistance
value
Below 1
Resistance
value
Below 1
Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
P01
20-316
and grounding
Voltage
Retraction range
Below 1V
Operation range
20 30 V
PC200/220(LC)-7
TROUBLESHOOTING
E116
PC200/220(LC)-7
20-317
(1)
TROUBLESHOOTING
E201
Service Code
Failure Code
E201
DW91KB
Failure
phenomenon
Failure content
Abnormal current flew to the travel interlocking circuit, when power was supplied to the circuit.
Response from
controller
Phenomenon
occurring on
machine
Relative
information
Operation of the travel interlocking solenoid (ON or OFF) can be checked in the monitoring function.
(Code No. 023: Solenoid)
Cause
Travel interlocking solenoid defective
1
(Internal short-circuiting
or grounding fault)
Assembled-type diode
2 D03 defective
(Internal short-circuiting)
Resistance value
20 60 z
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
D03 (male)
Resistance value
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Between wiring harness from C03 (female) (7) to J06 to
V02 (female) (1) and grounding, or between wiring harness between C03 (female) (7) and D03 (female) (3) and
grounding
Resistance
value
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it running during the
troubleshooting.
4
Governor pump
controller defective
C03
Between (7) and grounding
20-318
(7)
Voltage
Straight forward
Below 1 V
Steering
20 30 V
PC200/220(LC)-7
TROUBLESHOOTING
E201
PC200/220(LC)-7
20-319
(1)
TROUBLESHOOTING
E201
Service Code
Failure Code
E201
DW91KB
Failure
phenomenon
Failure content
Abnormal current flew to the travel interlocking circuit, when power was supplied to the circuit.
Response from
controller
Phenomenon
occurring on
machine
Relative
information
Operation of the travel interlocking solenoid (ON or OFF) can be checked in the monitoring function.
(Code No. 023: Solenoid)
Cause
Travel interlocking solenoid defective
1
(Internal short-circuiting
or grounding fault)
Resistance value
20 60 z
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Between wiring harness from C03 (female) (7) to V02
(female) (1) and grounding, or between wiring harness
between C03 (female) (7) and grounding
Resistance
value
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it running during the
troubleshooting.
3
Governor pump
controller defective
20-319-1
(7)
C03
Between (7) and grounding
Voltage
Straight forward
Below 1 V
Steering
20 30 V
PC200/220(LC)-7
TROUBLESHOOTING
E201
PC200/220(LC)-7
20-319-2
(5)
TROUBLESHOOTING
E203
Service Code
Failure Code
E03
E203
DW45KB
Failure
phenomenon
Failure content
Abnormal current flew to the swing holding brake solenoid circuit, when power was supplied to the circuit.
Response from
controller
Power supply to the swing holding brake solenoid circuit is switched OFF.
Even after the failure cause disappears of itself, the swing holding brake does not return to normalcy,
unless the engine starting switch is once turned OFF.
Phenomenon
occurring on
machine
The upper structure cannot swing. (The swing holding brake is not released)
Relative
information
Operation of the swing holding brake solenoid (ON or OFF) can be checked in the monitoring function.
(Code No. 023: Solenoid 1)
If there is no abnormality with the solenoid or wiring harness, the upper structure can swing by turning
the emergency swing brake releasing switch to the FREE position.
(In this case, however, the swing holding brake does not work, when stopping the machine)
Cause
Swing holding brake
solenoid defective
1
(Internal short-circuiting
or grounding fault)
Assembled-type diode
2 D03 defective
(Internal short-circuiting)
Resistance value
20 60 z
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
D03 (male)
Resistance value
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness from C03 (female) (37) to D01 to J02 to
X05 to J06 to V05 (female) (1), or between wiring harness
between C03 (female) (37) and D03 (female) (4) and
grounding
Resistance
value
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it running during the
troubleshooting.
4
Governor pump
controller defective
C03
Between (37) and grounding
20-320
(7)
Voltage
NEUTRAL
Below 1 V
Swing
20 30 V
PC200/220(LC)-7
TROUBLESHOOTING
E203
Electrical Circuit Diagram for Swing Holding Brake of Governor Pump Controller
PC200/220(LC)-7
20-321
(1)
TROUBLESHOOTING
E203
Service Code
Failure Code
E03
E203
DW45KB
Failure
phenomenon
Failure content
Abnormal current flew to the swing holding brake solenoid circuit, when power was supplied to the circuit.
Response from
controller
Power supply to the swing holding brake solenoid circuit is switched OFF.
Even after the failure cause disappears of itself, the swing holding brake does not return to normalcy,
unless the engine starting switch is once turned OFF.
Phenomenon
occurring on
machine
The upper structure cannot swing. (The swing holding brake is not released)
Relative
information
Operation of the swing holding brake solenoid (ON or OFF) can be checked in the monitoring function.
(Code No. 023: Solenoid 1)
If there is no abnormality with the solenoid or wiring harness, the upper structure can swing by turning
the emergency swing brake releasing switch to the FREE position.
(In this case, however, the swing holding brake does not work, when stopping the machine)
Cause
Swing holding brake
solenoid defective
1
(Internal short-circuiting
or grounding fault)
Resistance value
20 60 z
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness from C03 (female) (37) to D01 to J02 to
X05 to V05 (female) (1), or between wiring harness
between C03 (female) (37) and grounding
Resistance
value
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it running during the
troubleshooting.
3
Governor pump
controller defective
20-321-1
(7)
C03
Between (37) and grounding
Voltage
NEUTRAL
Below 1 V
Swing
20 30 V
PC200/220(LC)-7
TROUBLESHOOTING
E203
Electrical Circuit Diagram for Swing Holding Brake of Governor Pump Controller
PC200/220(LC)-7
20-321-2
(5)
TROUBLESHOOTING
E204
Service Code
Failure Code
E204
DWJ0KB
Failure
phenomenon
Failure content
Abnormal current flew to the merge/divide solenoid circuit, when power was supplied to the circuit.
Response from
controller
Phenomenon
occurring on
machine
In L mode, the work equipment moves slowly, or the swing speed is slow in its single operation.
(Front and rear pumps are not separated)
Relative
information
Operation of the merge/divide solenoid (ON or OFF) can be checked in the monitoring function.
(Code No. 023: Solenoid 1)
Cause
Merge/divide solenoid
defective
1
(Internal short-circuiting
or grounding fault)
Assembled-type diode
2 D03 defective
(Internal short-circuiting)
Grounding fault of wiring
harness
3
(Contact with grounding
circuit)
Resistance value
20 60 z
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
D03 (male)
Resistance value
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness from C03 (female) (17) to J06 to V03
(female) (1), or between wiring harness between C03
(female) (17) and D03 (female) (1) and grounding
Resistance
value
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it running during the
troubleshooting.
4
Governor pump
controller defective
20-322
(7)
C03
Voltage
NEUTRAL
Below 1 V
20 30 V
PC200/220(LC)-7
TROUBLESHOOTING
E204
PC200/220(LC)-7
20-323
(1)
TROUBLESHOOTING
E204
Service Code
Failure Code
E204
DWJ0KB
Failure
phenomenon
Failure content
Abnormal current flew to the merge/divide solenoid circuit, when power was supplied to the circuit.
Response from
controller
Phenomenon
occurring on
machine
In L mode, the work equipment moves slowly, or the swing speed is slow in its single operation.
(Front and rear pumps are not separated)
Relative
information
Operation of the merge/divide solenoid (ON or OFF) can be checked in the monitoring function.
(Code No. 023: Solenoid 1)
Cause
Merge/divide solenoid
defective
1
(Internal short-circuiting
or grounding fault)
Resistance value
20 60 z
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness from C03 (female) (17) to V03 (female)
(1), or between wiring harness between C03 (female) (17)
and grounding
Resistance
value
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it running during the
troubleshooting.
3
Governor pump
controller defective
20-323-1
(7)
C03
Voltage
NEUTRAL
Below 1 V
20 30 V
PC200/220(LC)-7
TROUBLESHOOTING
E204
PC200/220(LC)-7
20-323-2
(5)
TROUBLESHOOTING
E205
Service Code
Failure Code
E205
DWK0KB
Failure
phenomenon
Failure content
Abnormal current flew to the 2-stage relief solenoid circuit, when power was supplied to the circuit.
Response from
controller
Phenomenon
occurring on
machine
The one-touch power max. switch does not work. (The main relief valve is not set to high pressure)
Relative
information
Operation of the 2-stage relief solenoid (ON or OFF) can be checked in the monitoring function.
(Code No. 023: Solenoid 1)
Cause
2-stage relief solenoid
defective
1
(Internal short-circuiting
or grounding fault)
Assembled-type diode
2 D03 defective
(Internal short-circuiting)
Grounding fault of wiring
harness
3
(Contact with grounding
circuit)
Resistance value
20 60 z
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
D03 (male)
Resistance value
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness from C03 (female) (28) to J06 to V06
(female) (1), or between wiring harness between C03
(female) (28) and D03 (female) (2) and grounding
Resistance
value
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
4
Governor pump
controller defective
C03
Between (28) and grounding
20-324
(5)
Working mode
Voltage
Below 1 V
L mode
20 30 V
PC200/220(LC)-7
TROUBLESHOOTING
E205
Electric Circuit Diagram for 2-stage Relief Solenoid in Governor Pump Controller
PC200/220(LC)-7
20-325
(1)
TROUBLESHOOTING
E205
Service Code
Failure Code
E205
DWK0KB
Failure
phenomenon
Failure content
Abnormal current flew to the 2-stage relief solenoid circuit, when power was supplied to the circuit.
Response from
controller
Phenomenon
occurring on
machine
The one-touch power max. switch does not work. (The main relief valve is not set to high pressure)
Relative
information
Operation of the 2-stage relief solenoid (ON or OFF) can be checked in the monitoring function.
(Code No. 023: Solenoid 1)
Cause
2-stage relief solenoid
defective
1
(Internal short-circuiting
or grounding fault)
Resistance value
20 60 z
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness from C03 (female) (28) to V06 (female)
(1), or between wiring harness between C03 (female) (28)
and grounding
Resistance
value
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
3
Governor pump
controller defective
20-325-1
(7)
C03
Between (28) and grounding
Working mode
Voltage
Below 1 V
L mode
20 30 V
PC200/220(LC)-7
TROUBLESHOOTING
E205
Electric Circuit Diagram for 2-stage Relief Solenoid in Governor Pump Controller
PC200/220(LC)-7
20-325-2
(5)
TROUBLESHOOTING
E206
Service Code
Failure Code
E206
DW43KB
Failure
phenomenon
Failure content
Abnormal current flew to the travel speed shifting solenoid, when power was supplied to the circuit.
Response from
controller
Power supply to the travel speed shifting solenoid circuit is switched OFF.
Even after the failure cause disappears of itself, the machine operation does not return to normalcy,
unless the engine starting switch is once turned OFF.
Phenomenon
occurring on
machine
Relative
information
Operation of the travel speed shifting solenoid (ON or OFF) can be checked in the monitoring function.
(Code No. 023: Solenoid 1)
Cause
Travel speed shifting
solenoid defective
1
(Internal short-circuiting
or grounding fault)
Assembled-type diode
2 D04 defective
(Internal short-circuiting)
Grounding fault of wiring
harness
3
(Contact with grounding
circuit)
Resistance value
20 60 z
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
D04 (male)
Resistance value
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness from C03 (female) (27) to J06 to V04
(female) (1), or between wiring harness between C03
(female) (27) and D04 (female) (2) and grounding
Resistance
value
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it running during the
troubleshooting.
4
Governor pump
controller defective
C03
Between (27) and grounding
20-326
(7)
Voltage
Lo + Neutral
Below 1 V
Hi + Travel
20 30 V
PC200/220(LC)-7
TROUBLESHOOTING
E206
Electrical Circuit Diagram for Travel Speed Shifting Solenoid in Governor Pump Controller
PC200/220(LC)-7
20-327
(1)
TROUBLESHOOTING
E206
Service Code
Failure Code
E206
DW43KB
Failure
phenomenon
Failure content
Abnormal current flew to the travel speed shifting solenoid, when power was supplied to the circuit.
Response from
controller
Power supply to the travel speed shifting solenoid circuit is switched OFF.
Even after the failure cause disappears of itself, the machine operation does not return to normalcy,
unless the engine starting switch is once turned OFF.
Phenomenon
occurring on
machine
Relative
information
Operation of the travel speed shifting solenoid (ON or OFF) can be checked in the monitoring function.
(Code No. 023: Solenoid 1)
Cause
Travel speed shifting
solenoid defective
1
(Internal short-circuiting
or grounding fault)
Resistance value
20 60 z
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness from C03 (female) (27) to V04 (female)
(1), or between wiring harness between C03 (female) (27)
and grounding
Resistance
value
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it running during the
troubleshooting.
3
Governor pump
controller defective
20-327-1
(7)
C03
Between (27) and grounding
Voltage
Lo + Neutral
Below 1 V
Hi + Travel
20 30 V
PC200/220(LC)-7
TROUBLESHOOTING
E206
Electrical Circuit Diagram for Travel Speed Shifting Solenoid in Governor Pump Controller
PC200/220(LC)-7
20-327-2
(5)
TROUBLESHOOTING
E211
Service Code
Failure Code
E211
DW91KA
Failure
phenomenon
Failure content
No current flows to the travel interlocking solenoid circuit, when power is supplied to the circuit.
Response from
controller
None in particular (The solenoid does not function as there is current flowing to it)
When the failure cause disappears of itself, the machine operation returns to normalcy.
Phenomenon
occurring on
machine
Relative
information
Operation of the travel interlocking solenoid (ON or OFF) can be checked in the monitoring function.
(Code No. 023: Solenoid 1)
a The solenoid detects disconnection, when power is ON. Hence be sure to check it with power ON after
the repairs. (For how to turn power ON or OFF, refer to the troubleshooting under Service Code [E201].)
Cause
Travel interlocking
1 solenoid defective
(Internal disconnection)
Disconnection of wiring
harness
2 (Disconnection or defective contact with connector)
Short-circuiting of wiring
harness
3
(Contact with 24 V circuit)
Governor pump
controller defective
20-328
(7)
Resistance value
20 60 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness from C03 (female) (7) to J06 to V02
(female) (1)
Resistance
value
Below 1 z
Resistance
value
Below 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
Wiring harness from C03 (female) (7) to J06 to V02
(female) (1), or between wiring harness C03 (female) (7)
and D03 (female) (3) and grounding
Voltage
Below 1 V
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
C03 (female)
Resistance value
20 60 z
PC200/220(LC)-7
TROUBLESHOOTING
E211
Electrical Circuit Diagram for Travel Interlocking Solenoid in Governor Pump Controller
PC200/220(LC)-7
20-329
(1)
TROUBLESHOOTING
E211
Service Code
Failure Code
E211
DW91KA
Failure
phenomenon
Failure content
No current flows to the travel interlocking solenoid circuit, when power is supplied to the circuit.
Response from
controller
None in particular (The solenoid does not function as there is current flowing to it)
When the failure cause disappears of itself, the machine operation returns to normalcy.
Phenomenon
occurring on
machine
Relative
information
Operation of the travel interlocking solenoid (ON or OFF) can be checked in the monitoring function.
(Code No. 023: Solenoid 1)
a The solenoid detects disconnection, when power is ON. Hence be sure to check it with power ON after
the repairs. (For how to turn power ON or OFF, refer to the troubleshooting under Service Code [E201].)
Cause
Travel interlocking
1 solenoid defective
(Internal disconnection)
Disconnection of wiring
harness
2 (Disconnection or defective contact with connector)
Short-circuiting of wiring
harness
3
(Contact with 24 V circuit)
Governor pump
controller defective
20-329-1
(7)
Resistance value
20 60 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness from C03 (female) (7) to V02 (female) (1)
Resistance
value
Below 1 z
Resistance
value
Below 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
Wiring harness from C03 (female) (7) to V02 (female) (1),
or between wiring harness C03 (female) (7) and grounding
Voltage
Below 1 V
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
C03 (female)
Resistance value
20 60 z
PC200/220(LC)-7
TROUBLESHOOTING
E211
Electrical Circuit Diagram for Travel Interlocking Solenoid in Governor Pump Controller
PC200/220(LC)-7
20-329-2
(5)
TROUBLESHOOTING
E213
Service Code
Failure Code
E03
E213
DW45KA
Failure
phenomenon
Failure content
No current flows to the swing holding brake solenoid circuit, when power is supplied to the circuit.
Response from
controller
None in particular (The solenoid does not function as there is no current flowing to it)
When the failure cause disappears of itself, the machine operation returns to normalcy.
Phenomenon
occurring on
machine
The machine's upper structure does not swing. (The swing holding brake is not released)
Relative
information
Operation of the swing holding brake solenoid (ON or OFF) can be checked in the monitoring function.
(Code No. 023: Solenoid 1)
If there is abnormality neither with the solenoid nor with wiring harnesses, the upper structure can swing
by moving the emergency swing brake release switch to the FREE position. (In this case, however, the
parking brake does not work, when stopping the machine)
a While in troubleshooting, hold both the swing lock switch and the emergency swing release switch in
the OFF position.
a The solenoid detects disconnection, when power is ON. Hence be sure to check it with power ON after
the repairs. (For how to turn power ON or OFF, refer to the troubleshooting under Service Code [E203].)
Cause
Resistance value
20 60 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
X05 (female)
Between (3) and (4)
Resistance value
OFF
Below 1 z
LOCK
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
D01 (male)
Continuity
Diode mode
Continued
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
Disconnection of
wiring harness
4 (Disconnection or
defective contact
with connector)
Short-circuiting of
Wiring harness
5
(Contact with 24V
circuit)
Governor pump
controller defective
20-330
(7)
Wiring harness between C03 (female) (37) and D01 (female) (7)
Resistance
value
Below 1 z
Wiring harness from D01 (female) (3) to J02 to X05 (male) (3)
Resistance
value
Below 1 z
Wiring harness from X05 (male) (4) to J06 to V05 (female) (1)
Resistance
value
Below 1 z
Resistance
value
Below 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position during the troubleshooting.
Between wiring harness between C03 (female) (37) and D01
(female) (7) and grounding
Voltage
Below 1 V
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
C03 (female)
Disconnect D01 and connect pins
Between (37) and grounding (3) and (7) of the female side.
Resistance value
20 60 z
PC200/220(LC)-7
TROUBLESHOOTING
E213
Electrical Circuit Diagram for Swing Holding Brake Solenoid in Governor Pump Controller
PC200/220(LC)-7
20-331
(5)
TROUBLESHOOTING
E213
Service Code
Failure Code
E03
E213
DW45KA
Failure
phenomenon
Failure content
No current flows to the swing holding brake solenoid circuit, when power is supplied to the circuit.
Response from
controller
None in particular (The solenoid does not function as there is no current flowing to it)
When the failure cause disappears of itself, the machine operation returns to normalcy.
Phenomenon
occurring on
machine
The machine's upper structure does not swing. (The swing holding brake is not released)
Relative
information
Operation of the swing holding brake solenoid (ON or OFF) can be checked in the monitoring function.
(Code No. 023: Solenoid 1)
If there is abnormality neither with the solenoid nor with wiring harnesses, the upper structure can swing
by moving the emergency swing brake release switch to the FREE position. (In this case, however, the
parking brake does not work, when stopping the machine)
a While in troubleshooting, hold both the swing lock switch and the emergency swing release switch in
the OFF position.
a The solenoid detects disconnection, when power is ON. Hence be sure to check it with power ON after
the repairs. (For how to turn power ON or OFF, refer to the troubleshooting under Service Code [E203].)
Cause
Resistance value
20 60 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
X05 (female)
Between (3) and (4)
Resistance value
OFF
Below 1 z
LOCK
Above 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
D01 (male)
Continuity
Diode mode
Continued
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
Disconnection of
wiring harness
4 (Disconnection or
defective contact
with connector)
Short-circuiting of
Wiring harness
5
(Contact with 24V
circuit)
Governor pump
controller defective
20-331-1
(7)
Wiring harness between C03 (female) (37) and D01 (female) (7)
Resistance
value
Below 1 z
Wiring harness from D01 (female) (3) to J02 to X05 (male) (3)
Resistance
value
Below 1 z
Resistance
value
Below 1 z
Wiring harness between C03 (female) (3) (13) (23) and V05
(female) (2)
Resistance
value
Below 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position during the troubleshooting.
Between wiring harness between C03 (female) (37) and D01
(female) (7) and grounding
Voltage
Below 1 V
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
C03 (female)
Between (37) and (3) (13)
(23)
Resistance value
20 60 z
PC200/220(LC)-7
TROUBLESHOOTING
E213
Electrical Circuit Diagram for Swing Holding Brake Solenoid in Governor Pump Controller
PC200/220(LC)-7
20-331-2
(5)
TROUBLESHOOTING
E214
Service Code
Failure Code
E214
DWJ0KA
Failure
phenomenon
Failure content
No current flows to the merge/divide solenoid circuit, when power is supplied to the circuit.
Response from
controller
None in particular (The solenoid does not function as there is no current flowing to it)
When the failure cause disappears of itself, the machine operation returns to normalcy.
Phenomenon
occurring on
machine
In L mode, speeds of the work equipment and swing in its single operation are too fast
(Front and rear pumps are not separated)
Relative
information
Operation of the merge/divide solenoid (ON or OFF) can be checked in the monitoring function.
(Code No. 023: Solenoid 1)
a The solenoid detects disconnection, when power is ON. Hence be sure to check it with power ON after
the repairs. (For how to turn power ON or OFF, refer to the troubleshooting under Service Code [E204].)
Cause
Merge/divide solenoid
1 defective
(Internal disconnection)
Disconnection of wiring
harness
2 (Disconnection or defective contact with connector)
Short-circuiting of wiring
harness
3
(Contact with 24 V circuit)
Governor pump
controller defective
20-332
(7)
Resistance value
20 60 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness from C03 (female) (17) to J06 to V03
(female) (1)
Resistance
value
Below 1 z
Resistance
value
Below 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
Wiring harness from C03 (female) (17) to J06 to V03
(female) (1), or between wiring harness between C03
(female) (17) and D03 (female) (1) and grounding
Voltage
Below 1 V
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
C03 (female)
Resistance value
20 60 z
PC200/220(LC)-7
TROUBLESHOOTING
E214
PC200/220(LC)-7
20-333
(1)
TROUBLESHOOTING
E214
Service Code
Failure Code
E214
DWJ0KA
Failure
phenomenon
Failure content
No current flows to the merge/divide solenoid circuit, when power is supplied to the circuit.
Response from
controller
None in particular (The solenoid does not function as there is no current flowing to it)
When the failure cause disappears of itself, the machine operation returns to normalcy.
Phenomenon
occurring on
machine
In L mode, speeds of the work equipment and swing in its single operation are too fast
(Front and rear pumps are not separated)
Relative
information
Operation of the merge/divide solenoid (ON or OFF) can be checked in the monitoring function.
(Code No. 023: Solenoid 1)
a The solenoid detects disconnection, when power is ON. Hence be sure to check it with power ON after
the repairs. (For how to turn power ON or OFF, refer to the troubleshooting under Service Code [E204].)
Cause
Merge/divide solenoid
1 defective
(Internal disconnection)
Disconnection of wiring
harness
2 (Disconnection or defective contact with connector)
Short-circuiting of wiring
harness
3
(Contact with 24 V circuit)
Governor pump
controller defective
20-333-1
(7)
Resistance value
20 60 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness from C03 (female) (17) to V03 (female) (1)
Resistance
value
Below 1 z
Resistance
value
Below 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
Wiring harness from C03 (female) (17) to V03 (female) (1)
and grounding
Voltage
Below 1 V
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
C03 (female)
Resistance value
20 60 z
PC200/220(LC)-7
TROUBLESHOOTING
E214
PC200/220(LC)-7
20-333-2
(5)
TROUBLESHOOTING
E215
Service Code
Failure Code
E215
DWK0KA
Failure
phenomenon
Failure content
No current flows to the 2-stage relief solenoid circuit, when power is supplied to the circuit.
Response from
controller
None in particular (The solenoid does not function as there is no current flowing to it)
When the failure cause disappears of itself, the machine operation returns to normalcy.
Phenomenon
occurring on
machine
Relative
information
Operation of the 2-stage relief solenoid (ON or OFF) can be checked in the monitoring function.
(Code No. 023: Solenoid 1)
a The solenoid detects disconnection, when power is ON. Hence be sure to check it with power ON after
the repairs. (For how to turn power ON or OFF, refer to the troubleshooting under Service Code [E205].)
Cause
2-stage relief solenoid
1 defective
(Internal disconnection)
Disconnection of wiring
harness
2 (Disconnection or defective contact with connector)
Short-circuiting of wiring
harness
3
(Contact with 24 V circuit)
Governor pump
controller defective
20-334
(7)
Resistance value
20 60 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness from C03 (female) (28) to J06 to V06
(female) (1)
Resistance
value
Max. 1 z
Resistance
value
Max. 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
Wiring harness from C03 (female) (28) to J06 to V06
(female) (1), or between wiring harness between C03
(female) (28) and D03 (female) (2) and grounding
Voltage
Max. 1 V
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
C03 (female)
Resistance value
20 60 z
PC200/220(LC)-7
TROUBLESHOOTING
E215
Electrical Circuit Diagram for 2-stage Relief Solenoid in Governor Pump Controller
PC200/220(LC)-7
20-335
(1)
TROUBLESHOOTING
E215
Service Code
Failure Code
E215
DWK0KA
Failure
phenomenon
Failure content
No current flows to the 2-stage relief solenoid circuit, when power is supplied to the circuit.
Response from
controller
None in particular (The solenoid does not function as there is no current flowing to it)
When the failure cause disappears of itself, the machine operation returns to normalcy.
Phenomenon
occurring on
machine
Relative
information
Operation of the 2-stage relief solenoid (ON or OFF) can be checked in the monitoring function.
(Code No. 023: Solenoid 1)
a The solenoid detects disconnection, when power is ON. Hence be sure to check it with power ON after
the repairs. (For how to turn power ON or OFF, refer to the troubleshooting under Service Code [E205].)
Cause
2-stage relief solenoid
1 defective
(Internal disconnection)
Disconnection of wiring
harness
2 (Disconnection or defective contact with connector)
Short-circuiting of wiring
harness
3
(Contact with 24 V circuit)
Governor pump
controller defective
20-335-1
(7)
Resistance value
20 60 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness between C03 (female) (28) and V06
(female) (1)
Resistance
value
Max. 1 z
Resistance
value
Max. 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
Wiring harness from C03 (female) (28) to V06 (female) (1)
and grounding
Voltage
Max. 1 V
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
C03 (female)
Resistance value
20 60 z
PC200/220(LC)-7
TROUBLESHOOTING
E215
Electrical Circuit Diagram for 2-stage Relief Solenoid in Governor Pump Controller
PC200/220(LC)-7
20-335-2
(5)
TROUBLESHOOTING
E216
Service Code
Failure Code
E216
DW43KA
Failure
phenomenon
Failure content
No current flows to the travel speed shifting solenoid circuit, when power is supplied to the circuit.
Response from
controller
None in particular (The solenoid does not function as there is no current flowing to it)
When the failure cause disappears of itself, the machine operation returns to normalcy.
Phenomenon
occurring on
machine
Relative
information
Operation of the travel speed shifting solenoid (ON or OFF) can be checked in the monitoring function.
(Code No. 023: Solenoid 1)
a The solenoid detects disconnection, when power is ON. Hence be sure to check it with power ON after
the repairs. (For how to turn power ON or OFF, refer to the troubleshooting under Service Code [E206].)
Cause
Travel speed shifting
1 solenoid defective
(Internal disconnection)
Disconnection of wiring
harness
2 (Disconnection or defective contact with connector)
Short-circuiting of wiring
harness
3
(Contact with 24 V circuit)
Governor pump
controller defective
20-336
(7)
Resistance value
20 60 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness from C03 (female) (27) to J06 to V04
(female) (1)
Resistance
value
Max. 1 z
Resistance
value
Max. 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
Wiring harness from C03 (female) (27) to J06 to V04
(female) (1), or between wiring harness between C03
(female) (27) and D04 (female) (2) and grounding
Voltage
Max. 1 V
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
C03 (female)
Resistance value
20 60 z
PC200/220(LC)-7
TROUBLESHOOTING
E216
Electrical Circuit Diagram for Travel Speed Shifting Solenoid in Governor Pump Controller
PC200/220(LC)-7
20-337
(1)
TROUBLESHOOTING
E216
Service Code
Failure Code
E216
DW43KA
Failure
phenomenon
Failure content
No current flows to the travel speed shifting solenoid circuit, when power is supplied to the circuit.
Response from
controller
None in particular (The solenoid does not function as there is no current flowing to it)
When the failure cause disappears of itself, the machine operation returns to normalcy.
Phenomenon
occurring on
machine
Relative
information
Operation of the travel speed shifting solenoid (ON or OFF) can be checked in the monitoring function.
(Code No. 023: Solenoid 1)
a The solenoid detects disconnection, when power is ON. Hence be sure to check it with power ON after
the repairs. (For how to turn power ON or OFF, refer to the troubleshooting under Service Code [E206].)
Cause
Travel speed shifting
1 solenoid defective
(Internal disconnection)
Disconnection of wiring
harness
2 (Disconnection or defective contact with connector)
Short-circuiting of wiring
harness
3
(Contact with 24 V circuit)
Governor pump
controller defective
20-337-1
(7)
Resistance value
20 60 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness between C03 (female) (27) and V04
(female) (1)
Resistance
value
Max. 1 z
Resistance
value
Max. 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
Wiring harness from C03 (female) (27) to V04 (female) (1)
and grounding
Voltage
Max. 1 V
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
C03 (female)
Resistance value
20 60 z
PC200/220(LC)-7
TROUBLESHOOTING
E216
Electrical Circuit Diagram for Travel Speed Shifting Solenoid in Governor Pump Controller
PC200/220(LC)-7
20-337-2
(5)
TROUBLESHOOTING
E217
Service Code
Failure Code
E217
DA2SKQ
Failure
phenomenon
Failure content
A model code signal was inputted which indicates another model that is not registered in the controller.
Response from
controller
Phenomenon
occurring on
machine
Relative
information
Model names (expressed in number) that the controller recognizes can be confirmed in the monitoring
function. (Code No. 002 and 003: Controller Model Code)
a Input of model selecting signals (ON or OFF) can be confirmed in the monitoring
function.(Code No. 027:Switch Input 2)
Cause
Disconnection of wiring
harness
2 (Disconnection or defective contact with connector)
Resistance value
Max. 1 z
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness between C02 (female) (17) and C09
(male) (3)
Resistance
value
Max. 1 z
Resistance
value
Max. 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Grounding fault of wiring
harness
3
(Contact with grounding
circuit)
Resistance
value
Min. 1 Mz
Resistance
value
Min. 1 Mz
Resistance
value
Min. 1 Mz
Resistance
value
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
4
Governor pump
controller defective
20-338
(5)
C02
Voltage
20 30 V
Max. 1 V
PC200/220(LC)-7
TROUBLESHOOTING
E217
Electrical Circuit Diagram for Model Selecting Connector in Governor Pump Controller
PC200-7
PC200/220(LC)-7
20-339
(1)
TROUBLESHOOTING
E217
PC220-7
User Code
Service Code
Failure Code
E217
DA2SKQ
Failure
phenomenon
Failure content
A model code signal was inputted which indicates another model that is not registered in the controller.
Response from
controller
Phenomenon
occurring on
machine
Relative
information
Model names (expressed in number) that the controller recognizes can be confirmed in the monitoring
function. (Code No. 002 and 003: Controller Model Code)
a Input of model selecting signals (ON or OFF) can be confirmed in the monitoring
function.(Code No. 027:Switch Input 2)
Cause
Resistance value
Max. 1 z
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Disconnection of wiring
harness
2 (Disconnection or defective contact with connector)
Resistance
value
Max. 1 z
Resistance
value
Max. 1 z
Resistance
value
Max. 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Grounding fault of wiring
harness
3
(Contact with grounding
circuit)
Resistance
value
Min. 1 Mz
Resistance
value
Min. 1 Mz
Resistance
value
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
4
Governor pump
controller defective
20-340
(5)
C02
Voltage
20 30 V
Max. 1 V
PC200/220(LC)-7
E217
Electrical Circuit Diagram for Model Selecting Connector in Governor Pump Controller
PC220-7
PC200/220(LC)-7
20-341
E218
Service Code
Failure Code
E218
DA2SKA
Failure
phenomenon
Failure content
A failure occurred in S-NET communication between the monitor and controller in the past.
(The machine operation returned to normalcy, when the display was resumed)
Response from
controller
While the failure is still continuing, the machine operation is controlled by the following default setting.
1) Working mode: E mode
2) Travel speed: Lo
3) Auto-decelerator: ON
4) Attachment oil flow rate: Minimum ( )
When the failure cause disappears of itself, the machine operation returns to normalcy.
Phenomenon
occurring on
machine
Relative
information
This Service Code No. is displayed to inform that there was a failure occurred in the past, when S-NET
communication between the monitor panel and the governor pump controller is returned to normalcy.
The communication has already returned to normalcy by the time this Service Code No. is displayed.
But thoroughly diagnose all the related equipment and circuits, and remove all potential causes for a
failure in order to prevent recurrence of failures.
The working mode cannot be changed. (The display changes normally in the monitor panel)
The travel speed cannot be shifted. (The display changes normally in the monitor panel)
The auto-decelerator cannot be released. (The display changes normally in the monitor panel)
The attachment oil flow rate cannot be changed. (The display changes normally in the monitor panel) ( )
Cause
Disconnection of wiring
harness
1 (Disconnection or defective contact with connector)
and C02
and C02
Resistance
value
Below 1
Resistance
value
Below 1
Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
Between wiring harness between P02 (female)
C02 (female)
and grounding
and
Resistance
value
Above 1 M
Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
Between wiring harness between P02 (female)
C02 (female)
and grounding
and
Voltage
Below 1 V
Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
4 Monitor panel defective
P02 (male)
Between
Governor pump
controller defective
69V
Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
C02 (male)
Between
20-342
and
Voltage
and
Voltage
69V
PC200/220(LC)-7
TROUBLESHOOTING
E218
Electrical Circuit Diagram for S-NET Communication between Monitor Panel and Governor Pump
Controller
PC200/220(LC)-7
20-343
(1)
TROUBLESHOOTING
E222
Service Code
Failure Code
E222
DXE0KB
Failure
phenomenon
Response from
controller
Phenomenon
occurring on
machine
The travel speed is slow at Mi and Lo, or in L mode, speeds of the work equipment and swing are too
fast. (The LS valve set pressure cannot be controlled)
Relative
information
Failure content
Cause
LS-EPC solenoid defective
1
(Internal short-circuiting
or grounding fault)
Grounding fault of wiring
harness
2
(Contact with grounding
circuit)
Resistance value
7 14 z
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Between wiring harness between C03 (female) (6) and
V22 (female) (1) and grounding
Resistance
value
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
3
Governor pump
controller defective
C03 (female)
Resistance value
7 14 z
Min. 1 Mz
20-344
(5)
PC200/220(LC)-7
TROUBLESHOOTING
E223
Service Code
Failure Code
E223
DXE0KA
Failure
phenomenon
Failure content
Response from
controller
None in particular (The solenoid does not function as there is no current flowing to it)
When the failure cause disappears of itself, the machine operation returns to normalcy.
Phenomenon
occurring on
machine
The travel speed is slow at Mi and Lo, or in L mode, speeds of the work equipment and swing are too
fast. (The LS valve set pressure cannot be controlled)
Relative
information
Cause
LS-EPC solenoid defec1 tive
(Internal short-circuiting)
Disconnection of wiring
harness
2 (Disconnection or defective contact with connector)
Short-circuiting of wiring
harness
3
(Contact with 24 V circuit)
Governor pump
4
controller defective
Resistance value
7 14 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Between wiring harness between C03 (female) (6) and
V22 (female) (1) and grounding
Resistance
value
Max. 1 z
Resistance
value
Max. 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
Between wiring harness between C03 (female) (6) and
V22 (female) (1) and grounding
Voltage
Max. 1 V
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
C03 (female)
Resistance value
7 14 z
PC200/220(LC)-7
20-345
(5)
TROUBLESHOOTING
E224
Service Code
Failure Code
E224
DHPAMA
Failure
phenomenon
Failure content
Signal voltage from the F pump pressure sensor dropped below 0.3 V or exceeded 4.72 V.
Response from
controller
Phenomenon
occurring on
machine
Relative
information
Input from the F pump pressure sensor (pressure) can be confirmed in the monitor function.
(Code No. 011: F pump pressure)
Cause
A51
Voltage
Power supply
4.5 5.5 V
Signal
0.5 4.5 V
The pressure sensor voltage is measured with the wiring harness connected.
Accrdinaly, if the voltage is abnormal, check the wiring harness and controller, too, for
another cause of the trouble, and then judge.
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
Disconnection of wiring
harness
3 (Disconnection or defective contact with connector)
Resistance
value
Max. 1 z
Resistance
value
Max. 1 z
Resistance
value
Max. 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
Between wiring harness between C01 (female) (8) and
A51 (female) (C) and grounding
Resistance
value
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
Between wiring harness between C01 (female) (22), J07
and A51 (female) (B) and grounding
Voltage
Max. 1 V
Voltage
Max. 1 V
a Turn the engine starting switch OFF for the preparations, and keep the engine running
during the troubleshooting.
6
Governor pump
controller defective
20-346
(5)
C01
Voltage
Power supply
4.5 5.5 V
Signal
0.5 4.5 V
PC200/220(LC)-7
TROUBLESHOOTING
E224
Electrical Circuit Diagram for F Pump Pressure Sensor in Governor Pump Controller
PC200/220(LC)-7
20-347
(1)
TROUBLESHOOTING
E225
Service Code
Failure Code
E225
DHPBMA
Failure
phenomenon
Failure content
Signal voltage from the R pump pressure sensor dropped below 0.3 V or exceeded 4.42 V.
Response from
controller
Phenomenon
occurring on
machine
Relative
information
Input from the R pump pressure sensor (pressure) can be confirmed in the monitor function.
(Code No. 012: R pump pressure)
Cause
A52
Voltage
Power supply
4.5 5.5 V
Signal
0.5 4.5 V
The pressure sensor voltage is measured with the wiring harness connected.
Accrdinaly, if the voltage is abnormal, check the wiring harness and controller, too, for
another cause of the trouble, and then judge.
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
Disconnection of wiring
harness
3 (Disconnection or defective contact with connector)
Resistance
value
Max. 1 z
Resistance
value
Max. 1 z
Resistance
value
Max. 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
Between wiring harness between C01 (female) (2) and
A52 (female) (C) and grounding
Resistance
value
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
Between wiring harness between C01 (female) (22), J07
and A52 (female) (B) and grounding
Voltage
Max. 1 V
Voltage
Max. 1 V
a Turn the engine starting switch OFF for the preparations, and keep the engine running
during the troubleshooting.
6
Governor pump
controller defective
20-348
(5)
C01
Voltage
Power supply
4.5 5.5 V
Signal
0.5 4.5 V
PC200/220(LC)-7
TROUBLESHOOTING
E225
Electrical Circuit Diagram for R Pump Pressure Sensor in Governor Pump Controller
PC200/220(LC)-7
20-349
(1)
TROUBLESHOOTING
E226
Service Code in Electrical System E226 (Abnormality in pressure sensor power source)
User Code
Service Code
Failure Code
E226
DA25KP
Failure
phenomenon
Failure content
Abnormal current flew to the power source circuit (5 V) for the pressure sensors and potentiometer.
Response from
controller
The controller turns OFF power supply to the power source circuit (5 V).
Even when the failure cause disappears of itself, the current does not return to normalcy, unless the engine starting switch is once turned OFF.
Phenomenon
occurring on
machine
Signals from the pressure sensors and potentiometer are not inputted correctly.
The Service Code of "pressure sensor abnormal" and that of "potentiometer abnormal" are displayed at
the same time.
Cause
Pressure sensor or
1 potentiometer defective
(Internal short-circuit)
E06 Connector
E10 Connector
A51 Connector
A52 Connector
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
Governor pump
controller defective
20-350
(5)
Resistance
value
Min. 1 Mz
Resistance
value
Min. 1 Mz
Resistance
value
Min. 1 Mz
Resistance
value
Min. 1 Mz
Resistance
value
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
C01
Voltage
4.5 5.5 V
PC200/220(LC)-7
TROUBLESHOOTING
E226
Electrical Circuit Diagram for Sensor Power Source in Governor Pump Controller
PC200/220(LC)-7
20-351
(1)
TROUBLESHOOTING
E227
Service Code
Failure Code
E227
DLE2MA
Failure
phenomenon
Failure content
A normal pulse signal is not inputted to the signal circuit in the engine rotation sensor.
Response from
controller
Phenomenon
occurring on
machine
Relative
information
Input from the engine rotation sensor (rpm) can be confirmed in the monitor function.
(Code No. 010: Engine RPM)
Cause
Engine rotation sensor
fault
1
(Internal short-circuiting
or disconnection)
2
Disconnection of wiring
harness
3 (Disconnection or defective contact with connector)
Short-circuiting of wiring
harness
Resistance value
500 1,000 z
Min. 1 Mz
For the inspection and adjustment, refer to the section of "Adjusting Engine Rotation
Sensor" in this manual.
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness between C02 (female) (40) and E04
(female) (1)
Resistance
value
Max. 1 z
Resistance
value
Max. 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
(Contact with 24 V cir- Between wiring harness between C02 (female) (40) and
cuit)
E04 (female) (1) and grounding
Voltage
Max. 1 V
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
5
Governor pump
controller defective
C02 (female)
Resistance value
500 1,000 z
Min. 1 Mz
Electrical Circuit Diagram for Engine Rotation Sensor of Governor Pump Controller
20-352
(5)
PC200/220(LC)-7
TROUBLESHOOTING
E228
Service Code
Failure Code
E228
D196KB
Failure
phenomenon
Abnormal current flew to the attachment return switching relay circuit , when it was grounded (power ON).
Response from
controller
The controller turned OFF power to the attachment return switching relay circuit.
Even when the failure cause disappears of itself, the current does not return to normalcy.
Phenomenon
occurring on
machine
The hydraulic circuit for attachments is not switched to the single operation circuit.
(The switching valve is not switched to the tank circuit)
Relative
information
It can be confirmed in the monitor function how the attachment return switching relay circuit works (ON
or OFF). (Code No. 024:Solenoid 2)
This error code detects abnormality on the primary side (coil side) of the attachment return selector relay
and cannot detect abnormality on the secondary side (contact side).
Failure content
Cause
Attachment return
1 switching relay defective
(Internal short-circuiting)
Short-circuiting of wiring
harness
2
(Contact with 24 V circuit)
Resistance value
100 500 z
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
Between wiring harness between C02 (female) (8) and
R20 (female) (2) and grounding
Voltage
Max. 1 V
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
3
Governor pump
controller defective
C03
Between (8) and grounding
Working mode
Voltage
20 30 V
B mode
Max. 1 V
Electrical Circuit Diagram for Attachment Return Switching Relay and Solenoid
PC200/220(LC)-7
20-353
(5)
TROUBLESHOOTING
E232
Service Code
Failure Code
E02
E232
DXA0KB
Failure
phenomenon
Failure content
Response from
controller
Phenomenon
occurring on
machine
As load to the pump increases, the engine rotation drops sharply and sometimes the engine stalls.
(The pump absorption torque cannot be controlled)
Relative
information
Cause
PC-EPC solenoid defective
1
(Internal short-circuiting
or grounding fault)
Resistance value
7 14 z
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
S25 (male)
Emergency pump
drive switch
Normal
Resistance value
Min. 1 Mz
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Between wiring harness from C03 (female) (16) to S25
(female) (3) and grounding
Resistance
value
Min. 1 Mz
Resistance
value
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
4
Governor pump
controller defective
20-354
(5)
C03 (female)
Resistance value
7 14 z
Min. 1 Mz
PC200/220(LC)-7
TROUBLESHOOTING
E232
PC200/220(LC)-7
20-355
(1)
TROUBLESHOOTING
E233
Service Code
Failure Code
E02
E233
DXA0KA
Failure
phenomenon
Failure content
Response from
controller
None in particular (The solenoid does not function as there is no current flowing to it)
When the failure cause disappears of itself, the current returns to normalcy.
Phenomenon
occurring on
machine
As load to the pump increases, the engine rotation drops sharply and sometimes the engine stalls.
(The pump absorption torque cannot be controlled)
Relative
information
PC-EPC solenoid
1 defective
(Internal short-circuiting)
Resistance value
7 14 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Emergency pump driving
2 switch defective
(Internal disconnection)
S25
Emergency pump
driving switch
Resistance value
Normal
Max. 1 z
Emergency
Min. 1 Mz
Normal
Max. 1 z
Emergency
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Disconnection of wiring
harness
3 (Disconnection or
defective contact with
connector)
Short-circuiting of wiring
harness
4
(Contact with 24 V circuit)
Governor pump
controller defective
20-356
(5)
Resistance
value
Max. 1 z
Resistance
value
Max. 1 z
Resistance
value
Max. 1 z
Resistance
value
Max. 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
Between wiring harness between C03 (female) (16) and
S25 (female) (3) and grounding
Voltage
Max. 1 V
Voltage
Max. 1 V
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
C03 (female)
Resistance value
7 14 z
PC200/220(LC)-7
TROUBLESHOOTING
E233
PC200/220(LC)-7
20-357
(1)
TROUBLESHOOTING
E238
Service Code
Failure Code
E238
D196KA
Failure
phenomenon
Failure content
When the attachment switching relay circuit is disconnected from grounding (power OFF), 24 V voltage
is not generated.
Response from
controller
None in particular
If the failure cause disappears, the governor returns to normalcy.
Phenomenon
occurring on
machine
The hydraulic circuit for attachments cannot be switched to the single operation
(The switch valve cannot be switched to the tank circuit)
Relative
information
It can be confirmed in the monitor function how the attachment return switching relay circuit works (ON
or OFF). (Code No. 024:Solenoid 2)
This error code detects abnormality on the primary side (coil side) of the attachment return selector relay
and cannot detect abnormality on the secondary side (contact side).
Cause
Disconnection of wiring
harness
3 (Disconnection or
defective contact with
connector)
Resistance value
100 500 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness between C02 (female) (8) and R20
(female) (2)
Resistance
value
Max. 1 z
Resistance
value
Max. 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Between wiring harness between C02 (female) (8) and
R20 (female) (2) and grounding
Resistance
value
Min. 1 Mz
Resistance
value
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
5
Governor pump
controller defective
C03
Between (8) and grounding
20-358
(5)
Working mode
Voltage
20 30 V
B mode
Max. 1 V
PC200/220(LC)-7
TROUBLESHOOTING
E238
Electrical Circuit Diagram for Attachment Return Switching Relay and Solenoid in Governor Pump
Controller
PC200/220(LC)-7
20-359
(1)
TROUBLESHOOTING
E245
Service Code
Failure Code
E245
DXE4KB
Failure
phenomenon
Abnormal current flew to the attachment oil flow rate adjusting EPC solenoid circuit.
Response from
controller
The controller reduces to zero (0) power to the attachment oil flow rate adjusting EPC solenoid circuit.
Even when the failure cause disappears, the EPC solenoid circuit does not return to normalcy, unless
the engine starting switch is once turned OFF.
Phenomenon
occurring on
machine
The attachments do not move. (The PPC source pressure is not supplied to the service PPC valve)
Relative
information
It can be confirmed in the monitor function how power (ampere) is supplied to the attachment oil flow
rate adjusting EPC solenoid circuit. (Code No. 017: Service solenoid current)
Failure content
Cause
Attachment oil flow rate
adjusting EPC defective
1
(Internal short-circuiting
or grounding fault)
Grounding fault of wiring
harness
2
(Contact with grounding
circuit)
Resistance value
7 14 z
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Between wiring harness between C03 (female) (26) and
V30 (female) (1) and grounding
Resistance
value
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
3
Governor pump
controller defective
C03 (female)
Resistance value
7 14 z
Min. 1 Mz
Electrical Circuit Diagram for Attachment Oil Flow Rate Adjusting EPC Solenoid in Governor Pump
Controller
20-360
(5)
PC200/220(LC)-7
TROUBLESHOOTING
E246
Service Code
Failure Code
E246
DXE4KA
Failure
phenomenon
Failure content
No current flew to the attachment oil flow rate adjusting EPC solenoid circuit.
Response from
controller
None in particular (The solenoid does not work, as there is no current flowing to it)
If the failure cause disappears, the EPC solenoid circuit returns to normalcy of itself.
Phenomenon
occurring on
machine
The attachments do not move. (The PPC source pressure is not supplied to the service PPC valve)
Relative
information
It can be confirmed in the monitor function how power (ampere) is supplied to the attachment oil flow
rate adjusting EPC solenoid circuit. (Code No. 017: Service solenoid current)
Cause
Attachment oil flow rate
adjusting EPC defective
1
(Internal short-circuiting
or grounding fault)
Disconnection of wiring
harness
2 (Disconnection or defective contact with connector)
Short-circuiting of wiring
harness
3
(Contact with 24 V circuit)
Governor pump
controller defective
Resistance value
7 14 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Between wiring harness between C03 (female) (26) and
V30 (male) (1) and grounding
Resistance
value
Max. 1 z
Resistance
value
Max. 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
Between wiring harness between C03 (female) (26) and
V30 (female) (1) and grounding
Voltage
Max. 1 V
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
C03 (female)
Resistance value
7 14 z
Electrical Circuit Diagram for Attachment Oil Flow Rate Adjusting EPC Solenoid in Governor Pump
Controller
PC200/220(LC)-7
20-361
(5)
TROUBLESHOOTING
E256
Service Code
Failure Code
E256
DA20KT
Failure
phenomenon
Failure content
Response from
controller
None in particular
Even if the failure cause disappears, the nonvolatile memory does not return to normalcy, unless the
engine starting switch is once turned OFF.
Phenomenon
occurring on
machine
In some cases control parameters of the machines change, resulting in increase or decrease of the machine's power.
Relative
information
Recorded in the nonvolatile memory are part of the machine control parameters
Presumed
cause and
standard value
in normalcy
20-362
(1)
Cause
Governor pump
controller defective
PC200/220(LC)-7
TROUBLESHOOTING
E306
Service Code
Failure Code
E306
DK54KZ
Failure
phenomenon
Failure content
Signal voltage from the governor potentiometer dropped below 0.4 V or exceeded 4.6 V.
Response from
controller
The controller exercises control by computing the motor position through voltage right before a failure
occurred.
Even if the failure cause disappears of itself, the governor potentiometer does not return to normalcy,
unless the engine starting switch is once turned OFF.
Phenomenon
occurring on
machine
Relative
information
Input from the governor potentiometer (voltage) can be confirmed in the monitor function.
(Code No. 031: Governor potentiometer voltage)
The engine cannot attain the specified rotation at high idle. (A bit lower)
The engine cannot attain the specified rotation at low idle (A bit higher)
The auto-decelerator or automatic warming-up function does not work.
There is hunting while the engine is running.
The engine stalls.
The engine does not stop.
Cause
1
Governor potentiometer
2 defective
(Internal failure)
E10 (male)
Resistance value
4.0 6.0 kz
0.25 5.0 kz
0.25 5.0 kz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Disconnection of wiring
harness
3 (Disconnection or defective contact with connector)
Resistance
value
Max. 1 z
Resistance
value
Max. 1 z
Resistance
value
Max. 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Between wiring harness between C01 (female) (13) and
E10 (female) (B) and grounding
Resistance
value
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
Between wiring harness from C01 (female) (22) to J07 to
E10 (female) (A) and grounding
Voltage
Max. 1 V
Voltage
Max. 1 V
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
6
Governor pump
controller defective
20-364
(11)
C01
Resistance value
Power supply
4.5 5.5 V
Signal
0.5 4.5 V
PC200/220(LC)-7
TROUBLESHOOTING
E306
PC200/220(LC)-7
20-365
(1)
TROUBLESHOOTING
E308
Service Code
Failure Code
E05
E308
DK10KZ
Failure
phenomenon
Failure content
Signal voltage from the from fuel dropped below 0.23 V or exceeded 4.77 V.
Response from
controller
The controller exercises control by computing the fuel dial position through voltage right before a failure
occurred.
If the failure cause disappears, the fuel dial returns to normalcy.
Phenomenon
occurring on
machine
Relative
information
Input from the fuel dial (voltage) can be confirmed in the monitor function.
(Code No. 030: Fuel dial voltage)
If the fuel dial had been set at FULL before a failure occurred, it does not change to PARTIAL.
If the fuel dial had been set at PARTIALLY before a failure occurred, it does not change to FULL.
There is hunting while the engine is running.
The engine cannot attain the specified rotation at high idle and lacks power.
Cause
Sensor power source
1
defective
Disconnection of wiring
harness
2 (Disconnection or defective contact with connector)
Resistance value
4.0 6.0 kz
0.25 5.0 kz
0.25 5.0 kz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Disconnection of wiring
harness
3 (Disconnection or defective contact with connector)
Resistance
value
Max. 1 z
Resistance
value
Max. 1 z
Resistance
value
Max. 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Between wiring harness between C01 (female) (19) and
E06 (female) (2) and grounding
Resistance
value
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
Between wiring harness from C01 (female) (22) to J07 to
E06 (female) (1) and grounding
Voltage
Max. 1 V
Voltage
Max. 1 V
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
6
Governor pump
controller defective
20-366
(11)
C01
Resistance value
Power supply
4.5 5.5 V
Signal
0.5 4.5 V
PC200/220(LC)-7
TROUBLESHOOTING
E308
PC200/220(LC)-7
20-367
(1)
TROUBLESHOOTING
E315
Service Code
Failure Code
E315
D110KB
Failure
phenomenon
Abnormal current flew to the battery relay drive circuit, when power was supplied to the circuit.
Response from
controller
Phenomenon
occurring on
machine
Relative
information
It can be confirmed in the monitor function how the battery relay works (ON or OFF).
(Code No. 037: Controller output)
Failure content
Cause
Governor pump
controller defective
20-368
(5)
Battery relay
Continued
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Between wiring harness from C03 (female) (4) to D01 to
J01 to A21 (BR terminal) and grounding
Resistance
value
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
C03
Voltage
ON o OFF
20 30 V
(for 4 to 7 seconds)
PC200/220(LC)-7
E315
PC200/220(LC)-7
20-369
E316
Service Code
Failure Code
E316
DY10K4
Failure
phenomenon
Failure content
There is a big difference between signals from the potentiometer and the set values in the controller.
Response from
controller
Phenomenon
occurring on
machine
Cause
4 Governor motor defective (short-circuiting) If Service Code [E318] is displayed, troubleshoot that failure first.
5 Governor lever adjustment improper
Refer to the section of "Inspection and Adjustment - Special Function of Monitor Panel" in this manual.
20-370
PC200/220(LC)-7
TROUBLESHOOTING
E317
Service Code in Electrical System E317 (Disconnection in governor motor Phase A and B)
User Code
Service Code
Failure Code
E05
E317
DY10KA
Failure
phenomenon
Failure content
No current flew to the governor motor, when power was supplied to the motor.
Response from
controller
None in particular.
If the failure cause disappears, the governor returns to normalcy.
Phenomenon
occurring on
machine
Relative
information
Operation of the governor motor (current) can be confirmed in the monitor function.
(Code No. 033: Governor motor Phase A current, Code No. 034: Governor motor Phase B current)
Cause
Resistance value
Between
and
2.5 7.5 z
Between
and
2.5 7.5 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Disconnection of wiring
harness
2 (Disconnection or defective contact with connector)
and E11
Resistance
value
Max. 1 z
and E11
Resistance
value
Max. 1 z
and E11
Resistance
value
Max. 1 z
and E11
Resistance
value
Max. 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
3
Governor pump
controller defective
20-372
(11)
C03 (female)
Resistance value
Between
and
2.5 7.5 z
Between
and
2.5 7.5 z
PC200/220(LC)-7
TROUBLESHOOTING
E317
PC200/220(LC)-7
20-373
(1)
TROUBLESHOOTING
E318
Service Code
Failure Code
E318
DY10KB
E05
Failure
phenomenon
Failure content
Abnormal current flew to the governor motor, when power is supplied to the motor.
Response from
controller
None in particular
If the failure cause disappears, the governor motor returns to normalcy.
Phenomenon
occurring on
machine
Relative
information
Operation of the governor motor (current) can be confirmed in the monitor function.
(Code No. 033: Governor motor Phase A current, Code No. 034: Governor motor Phase B current)
Cause
E11 (male)
Resistance value
Between
and
2.5 7.5 z
Between
and
2.5 7.5 z
Between
and grounding
Min. 1 Mz
Between
and grounding
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Disconnection of wiring
harness
2 (Disconnection or defective contact with connector)
and
Resistance
value
Min. 1 Mz
and
Resistance
value
Min. 1 Mz
and
Resistance
value
Min. 1 Mz
and
Resistance
value
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
C03 (female)
Governor pump
controller defective
20-374
(11)
Resistance value
Between
and
2.5 7.5 z
Between
and
2.5 7.5 z
Between
and grounding
Min. 1 Mz
Between
and grounding
Min. 1 Mz
Between
and grounding
Min. 1 Mz
Between
and grounding
Min. 1 Mz
PC200/220(LC)-7
E318
PC200/220(LC)-7
20-375
E501 / E502
Service Code in Electrical System E501 ("Model Selection" function not provided yet)
User Code
Service Code
Failure Code
E501
DA2AKM
Failure
phenomenon
Failure content
Response from
controller
Phenomenon
occurring on
machine
Relative
information
Model names that the controller recognizes (figure) can be confirmed in the monitor function.
(Code No. 150: Model Code)
Cause
Presumed
cause and
standard value
in normalcy
20-376
Governor pump
controller defective
PC200/220(LC)-7
TROUBLESHOOTING
E501 / E502
Service Code
Failure Code
E502
DA20KT
Failure
phenomenon
Failure content
Response from
controller
Phenomenon
occurring on
machine
Relative
information
(Model names that the controller recognizes (figure) can be confirmed in the monitor function.
(Code No. 150: Model Code)
Cause
Presumed
cause and
standard value
in normalcy
Governor pump
controller defective
PC200/220(LC)-7
20-377
(1)
TROUBLESHOOTING
A000N1 / A000N2
Failure Code in Mechanical System A000N1 (Out-of-rate engine rotation at high idle)
User Code
Service Code
Failure Code
A000N1
Failure
phenomenon
Failure content
Engine rotation above 2,350 rpm was detected for more than 10 seconds, while the engine was running.
Response from
controller
None in particular
If the failure cause disappears of itself, the engine rotation returns to normalcy.
Phenomenon
occurring on
machine
There is a possibility that the engine is damaged, if is used continuously without adjustment.
Relative
information
Input from the engine rotation sensor (rpm) can be confirmed in the monitor function.
(Code No. 010: Engine rotation)
Cause
Presumed
cause and
standard value
in normalcy
Check if there has been an internal or external factor that would cause
Failure in engine mechanthe engine to overrun at high idle, and troubleshoot the mechanical sysical system
tem of the engine.
Governor pump
controller defective
Failure Code in Mechanical System A000N2 (Out-of-rate engine rotation at low idle)
User Code
Service Code
Failure Code
A000N2
Failure
phenomenon
Failure content
Engine rotation below 500 rpm was detected for more than 10 seconds, while the engine was running.
Response from
controller
None in particular
If the failure cause disappears of itself, the rotation returns to normalcy.
Phenomenon
occurring on
machine
There is a possibility that the engine is damaged, if it is used continuously without adjustment.
Relative
information
Input from the engine rotation sensor (rpm) can be confirmed in the monitor function.
(Code No. 010: Engine rotation)
Cause
Presumed
cause and
standard value
in normalcy
20-378
(11)
Check if there has been an internal or external factor that would cause
Failure in engine mechanthe engine to overrun at high idle, and troubleshoot the mechanical sysical system
tem of the engine.
Governor pump
controller defective
PC200/220(LC)-7
TROUBLESHOOTING
AA10NX
Service Code
Failure Code
AA10NX
Failure
phenomenon
Failure content
While the engine was running, the signal circuit in the air cleaner clogging switch was opened (i.e. disconnected from grounding circuit).
Response from
monitor panel
None in particular
Phenomenon
occurring on
machine
There is a possibility that the engine is damaged, if it is used continuously without corrective action.
Relative
information
This Failure Code is recorded, when the air cleaner clogging caution symbol is displayed in the monitor
panel while the engine is running.
Input from the air cleaner clogging switch (ON or OFF) can be confirmed in the monitor panel.
(Code No. 046: Monitor input 2)
Cause
Air cleaner clogged
1 (when the system is in
normal condition)
Air cleaner clogging
2 switch defective
(Internal disconnection)
Disconnection of wiring
harness
3 (Disconnection or defective contact with connector)
Air cleaner
Resistance value
Max. 1 z
When clogged
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it running during the
troubleshooting.
Wiring harness between P02 (female) (5) and A31
(female) (1)
Resistance
value
Max. 1 z
Resistance
value
Max. 1 z
a Turn the engine starting switch OFF for the preparations, and keep the engine running
during the troubleshooting.
4 Monitor panel defective
P02
Between (5) and grounding
Air cleaner
Voltage
Max. 1 V
When clogged
20 30 V
PC200/220(LC)-7
20-379
(5)
TROUBLESHOOTING
AB00KE
Service Code
Failure Code
AB00KE
Failure
phenomenon
Failure content
Generation signal from the alternator is not inputted, while the engine is running.
Response from
monitor panel
None in particular
Phenomenon
occurring on
machine
There is a possibility that the battery may not be charged, if charging is continued without corrective
action.
Relative
information
This Failure Code is recorded, if the charging caution symbol is displayed in the monitor panel, while the
engine is running.
Input from the alternator (voltage) can be confirmed in the monitor function.
(Code No. 043: Charging voltage)
Cause
Alternator defective
(short generating output)
Disconnection of wiring
harness
2 (Disconnection or defective contact with connector)
Grounding fault of wiring
harness
3
(Contact with grounding
circuit)
20-380
(5)
Engine rotation
Voltage
27.5 29.5 V
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness from P02 (female) (11) to J02 to E12
(female) (1)
Resistance
value
Max. 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness from P02 (female) (11) to J02 to E12
(female) (1), or between P02 (female) (11) and D01 (female)
(6), or between P02 (female) (11) and A27 (female) (2)
Resistance
value
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and keep the engine running
during the troubleshooting.
P02
Engine rotation
Voltage
27.5 29.5 V
PC200/220(LC)-7
TROUBLESHOOTING
AB00KE
Electrical Circuit Diagram for Engine Start, Stop and Charging in Monitor Panel
PC200, 200LC-7 Serial No. 200001 250000
PC220, 220LC-7 Serial No. 60001 65000
PC200/220(LC)-7
20-381
(5)
TROUBLESHOOTING
AB00KE
Electrical Circuit Diagram for Engine Start, Stop and Charging in Monitor Panel
PC200, 200LC-7 Serial No. 250001 and up
PC220, 220LC-7 Serial No. 65001 and up
20-381-1
(8)
PC200/220(LC)-7
TROUBLESHOOTING
B@BAZG
Failure Code in Mechanical System B@BAZG (Abnormally lowered engine oil pressure)
User Code
Service Code
Failure Code
B@BAZG
Failure
phenomenon
Failure content
The signal circuit in the engine oil pressure switch was closed (i.e. connected with grounding), while the
engine was running.
Response from
monitor panel
None in particular
Phenomenon
occurring on
machine
There is a possibility that the engine may seize, if the engine is kept running without corrective action.
Relative
information
This Failure Code is recorded, if the engine oil pressure caution symbol is displayed in the monitor panel,
while the engine is running.
Input from the engine oil pressure switch (ON or OFF) can be confirmed in the monitor function.
(Code No. 046: Monitor input 2)
Cause
Engine oil pressure low1 ered (the system in normal condition)
Engine oil pressure
2 switch defective
(Internal short-circuiting)
Resistance value
Min. 1 Mz
When lowered
Max. 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Between wiring harness between P02 (female) (7) and E02
(terminal) and grounding
Resistance
value
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and keep the engine running
during the troubleshooting.
4 Monitor panel defective
P02
Between (7) and grounding
Voltage
20 30 V
When lowered
Max. 1 V
Electrical Circuit Diagram for Engine Oil Pressure Switch in Monitor Panel
20-382
(5)
PC200/220(LC)-7
TROUBLESHOOTING
B@BAZK
Failure Code in Mechanical System B@BAZK (Abnormally lowered engine oil level)
User Code
Service Code
Failure Code
B@BAZK
Failure
phenomenon
Failure content
The signal circuit in the engine oil level switch was opened (i.e. disconnected from grounding), when the
engine is stopped (with the starting switch in the ON position).
Response from
monitor panel
None in particular
Phenomenon
occurring on
machine
There is a possibility that the engine seizes if it is kept running without a corrective action.
Relative
information
This Failure Code is recorded if the engine oil level caution symbol is displayed, when the engine is
stopped (with the starting key in the ON position).
Input from the engine oil level switch (ON or OFF) can be confirmed in the monitor function. (Code No.
046: Monitor input 2)
Cause
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
E03 (male)
Between (1) and grounding
Resistance value
Max. 1 z
When lowered
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness between P02 (female) (8) and E03 (female)
(1)
Resistance
value
Max. 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
4 Monitor panel defective
P02
Between (8) and grounding
Voltage
Max. 1 V
When lowered
20 30 V
Electrical Circuit Diagram for Engine Oil Level Switch in Monitor Panel
PC200/220(LC)-7
20-383
(5)
TROUBLESHOOTING
B@BCNS
Service Code
Failure Code
B@BCNS
Failure
phenomenon
Failure content
The engine coolant sensor inputted a signal of 102C, while the engine was running.
Response from
monitor panel
Phenomenon
occurring on
machine
There is a possibility that the engine seizes, if it is kept running without a corrective action.
Relative
information
This Failure Code is recorded, if the engine coolant temperature gauge is displayed in the red range,
when the engine is running.
Input from the engine coolant temperature sensor (temperature) can be confirmed in the monitor function. (Code No. 041: Engine coolant temperature)
Cause
Engine Overheating
1 (system in normal condition)
E05 (male)
Between (1) and (2)
Between (2) and grounding
Engine coolant
temperature
Resistance value
90 3.5 kz
10 100 C
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Between wiring harness between P02 (female) (1) and
E05 (female) (2) and grounding
Resistance
value
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
4 Monitor panel defective
P02 (female)
Between (1) and (13)
Between (1) and grounding
Engine coolant
temperature
10 100 C
Resistance value
90 3.5 kz
Min. 1 Mz
Electrical Circuit Diagram for Engine Coolant Temperature Sensor in Monitor Panel
20-384
(11)
PC200/220(LC)-7
TROUBLESHOOTING
B@BCZK
Failure Code in Mechanical System B@BCZK (Abnormally lowered radiator coolant level)
(Multi-monitor only)
User Code
Service Code
Failure Code
B@BCZK
Failure
phenomenon
Failure content
The signal circuit in the radiator coolant level switch was opened (i.e. disconnected from grounding).
Response from
monitor panel
None in particular
Phenomenon
occurring on
machine
There is a possibility that the engine seizes, if it is kept running without a corrective action.
Relative
information
This Failure Code is recorded, if the radiator coolant level caution symbol is displayed in the monitor
panel, when the engine is running.
Input from the radiator coolant level switch (ON or OFF) can be confirmed in the monitor function.
(Code No. 045: Monitor input 1)
Cause
Radiator coolant level
1 lowered (system in normal condition)
Radiator coolant level
2 switch defective
(Internal disconnection)
Disconnection of wiring
harness
3 (Disconnection or defective contact with connector)
Resistance value
Max. 1 z
When lowered
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness between P02 (female) (3) and A33 (female)
(1)
Resistance
value
Max. 1 z
Resistance
value
Max. 1 z
a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
4 Monitor panel defective
P02
Between (3) and grounding
Engine coolant
temperature
Resistance value
Max. 1 V
When lowered
20 30 V
Electrical Circuit Diagram for Radiator Coolant Level Switch in Monitor Panel
PC200/220(LC)-7
20-385
(11)
TROUBLESHOOTING
B@HANS
Service Code
Failure Code
B@HANS
Failure
phenomenon
Failure content
The hydraulic oil temperature sensor inputted a signal of 102C, while the engine was running.
Response from
monitor panel
None in particular
Phenomenon
occurring on
machine
There is a possibility that the engine seizes, if it is kept running without a corrective action.
Relative
information
This Failure Code is recorded, if the hydraulic oil temperature gauge is displayed in the red range, when
the engine is running.
Input from the hydraulic oil temperature sensor (temperature) can be confirmed in the monitor function.
(Code No. 044: Hydraulic oil temperature)
Cause
Hydraulic oil overheat1 ing (system in normal
condition)
Hydraulic oil temperature
2 sensor defective
(Internal short-circuiting)
Resistance value
90 3.5 kz
10 100 C
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Between wiring harness between P02 (female) (12) and
A61 (female) (2) and grounding
Resistance
value
Min. 1 Mz
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
4 Monitor panel defective
P02 (female)
Between (12) and (13)
Between (12) and grounding
Resistance value
90 3.5 kz
Min. 1 Mz
Electrical Circuit Diagram for Hydraulic Oil Temperature Sensor in Monitor Panel
20-386
(5)
PC200/220(LC)-7