OpenScape Alarm Response Professional V3, Service Documentation, Issue 1

Download as pdf or txt
Download as pdf or txt
You are on page 1of 134

Documentation

OpenScape Alarm Response Professional


OScAR-Pro V3 R2 Classic Applications
Administrator Manual

A31003-S1730-S103-1-7620

Communication for the open minded

Siemens Enterprise Communications


www.siemens-enterprise.com

Our Quality and Environmental Management Systems are implemented according to the requirements of the ISO9001 and ISO14001 standard certified by an external certification company.

Copyright Siemens Enterprise


Communications GmbH & Co. KG 2010
Hofmannstr. 51, 80200 Mnchen
Siemens Enterprise Communications GmbH & Co. KG
is a Trademark Licensee of Siemens AG
Reference No.: A31003-S1730-S103-1-7620

Communication for the open minded


Siemens Enterprise Communications
www.siemens-enterprise.com

The information provided in this document contains


merely general descriptions or characteristics of
performance which in case of actual use do not
always apply as described or which may change as
a result of further development of the products. An
obligation to provide the respective characteristics
shall only exist if expressly agreed in the terms of
contract. Availability and technical specifications are
subject to change without notice.
OpenScape, OpenStage and HiPath are registered
trademarks of Siemens Enterprise
Communications GmbH & Co. KG.
All other company, brand, product and service
names are trademarks or registered trademarks of
their respective holders.

DAKS Rel7 Hardware_IVZ.fm


Nur fr den internen Gebrauch

Table of Content

Table of Content
1 Conventions and Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1 Overview of chapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.2 Notations and symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13 Data protection and data safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

X
1-1
1-2
1-3
1-4

2 Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1


3 Server Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
4 Product Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
4.1 Subrack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
4.2 Boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
4.2.1 General information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
4.2.1.1 Power supply boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
4.2.1.2 Bus boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
4.2.1.3 Status indicator for bus boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
4.2.1.4 Status indicator Power supply boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
4.2.2 ACP-41: AC Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
4.2.3 DCP-41: DC Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
4.2.4 CPC-41: Controller board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14
4.2.5 PRA-41: Primary-rate adapter (E1/T1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16
4.2.6 BRA-41: Basic-rate adapter (S0). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-18
4.2.7 DSP-41: Digital signal processor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20
4.2.8 SIO-41: Serial interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-22
4.2.9 DIO-41: Digital inputs and outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24
4.2.10 AIO-41: Audio interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-26
4.3 CompactFlash card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-28
4.4 Add ons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-29
4.4.1 USB adapter for DCF-77 radio receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-29
4.4.2 DCF-77 radio receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-30
4.4.3 Printer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-32
4.4.4 USB/RS232 interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-33
4.5 Line extensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-34
4.5.1 CSA-Converter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-34
4.5.2 E-Link: Line extension modem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-35
4.5.3 Dialing modem (analog) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-36
4.5.4 Dialing modem (digital) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-36
4.5.5 GSM modem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-36
4.5.6 Transmission kit for OScAR-Pro to PC/Host . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-37
4.5.7 Transmission kit for PC/Host. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-38
4.5.8 Transmission kit for OScAR-Pro to Printer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-39
4.5.9 Transmission kit for Printer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-40

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

X-1

DAKS Rel7 Hardware_IVZ.fm

Table of Content

Nur fr den internen Gebrauch

4.6 General adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


4.6.1 DCE adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.6.1.1 DCE-01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.6.1.2 DCE-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.6.2 DTE adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.6.3 PRN adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.6.4 PRT adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.6.5 RJ45 socket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.6.6 Patch field. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.6.7 Converter from RS422/RS485 to RS232 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.7 General cable cords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.7.1 DC power cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.7.2 AC connector cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.7.3 USB cable cord. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.7.4 Patch cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.7.5 Connector cable for digital inputs and outputs . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.7.6 RS232 data cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.7.7 Connector cable OScAR-Pro to CV422-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.7.8 Connector cable Sigmasys to CV422-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.8 Profibus-DP with ET 200. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.8.1 Input module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.8.2 Terminal block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.8.3 Electric power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.8.4 Profibus adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.8.5 Profibus-Server connector cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.8.6 Profibus extension cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.8.7 Installation of the bus connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.8.8 Top-hat rail for Profibus modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4-41
4-41
4-41
4-42
4-43
4-44
4-45
4-46
4-46
4-47
4-48
4-48
4-49
4-49
4-50
4-51
4-55
4-56
4-57
4-58
4-58
4-58
4-59
4-59
4-60
4-61
4-62
4-62

5 Hardware Operations on the OScAR-Pro Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1


5.1 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
5.2 Country-specific safety instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4
5.2.1 Denmark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4
5.2.2 Finland . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4
5.2.3 Sweden. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4
5.3 Rack installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5
5.4 Convert to tabletop solution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-8
5.5 Install boards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-9
5.6 Remove boards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-12
5.7 Insert and Remove the CompactFlash card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-14
5.8 Install a bus expansion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-15

X-2

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

DAKS Rel7 Hardware_IVZ.fm


Nur fr den internen Gebrauch

Table of Content

6 Wiring plans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1


6.1 CPC-41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
6.2 PRA-41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
6.3 BRA-41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
6.4 SIO-41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8
6.5 DIO-41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-10
6.6 Line extension of the COM interface (CSA-01-0X) . . . . . . . . . . . . . . . . . . . . . . . . . . 6-12
6.7 Line extension of the Protocol printer for logging (Leiser) . . . . . . . . . . . . . . . . . . . . . 6-14
6.8 Line extension of the Host interface (Leiser) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-16
6.9 Line extension via E-Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-18
6.10 Line extension Sigmasys fire alarm system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-20
6.11 Contact inputs via Profibus-DP with ET 200L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-22
6.11.1 Overall wiring plan. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-22
6.11.2 Module and power supply for make contacts . . . . . . . . . . . . . . . . . . . . . . . . . . 6-23
6.11.3 Module wiring for break contacts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-24
7 Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Z-1

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

X-3

DAKS Rel7 Hardware_IVZ.fm

Table of Content

X-4

Nur fr den internen Gebrauch

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

DAKS Rel7 Hardware_TVZ.fm


Nur fr den internen Gebrauch

List of Tables
Table 1-1
Table 1-2
Table 3-1
Table 4-1
Table 4-2
Table 4-3
Table 4-4
Table 4-5
Table 4-6
Table 4-7
Table 4-8
Table 4-9
Table 4-10
Table 4-11
Table 4-12
Table 4-13
Table 4-14
Table 4-15
Table 4-16
Table 4-17
Table 4-18
Table 4-19
Table 4-20
Table 4-21
Table 4-22
Table 6-1
Table 6-2
Table 6-3
Table 6-4
Table 6-5
Table 6-6
Table 6-7
Table 6-8
Table 6-9
Table 6-10

List of Tables

Overview of chapters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2


Notations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
System specification of the OScAR-Pro server. . . . . . . . . . . . . . . . . . . . . 3-1
Population options of the power supply units: ACP-41 and DCP-41. . . . . 4-4
Connectors and outputs of the front plate ACP-41 . . . . . . . . . . . . . . . . . 4-11
Connectors and outputs of the front plate DCP-41 . . . . . . . . . . . . . . . . . 4-13
Connectors and outputs of the front plate CPC-41 . . . . . . . . . . . . . . . . . 4-15
Connectors and outputs of the front plate PRA-41 . . . . . . . . . . . . . . . . . 4-17
Connectors and outputs of the front plate BRA-41 . . . . . . . . . . . . . . . . . 4-19
Outputs of the front plate DSP-41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21
Connectors and outputs of the front plate SIO-41. . . . . . . . . . . . . . . . . . 4-23
Connectors and outputs of the front plate DIO-41. . . . . . . . . . . . . . . . . . 4-25
Connectors and outputs of the front plate AIO-41. . . . . . . . . . . . . . . . . . 4-27
USB adapter for DCF-77 radio receiver . . . . . . . . . . . . . . . . . . . . . . . . . 4-29
AD450: DCF-77 radio receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-30
Position of DIL switches on the interface board. . . . . . . . . . . . . . . . . . . . 4-32
Line extension E-Link IV, Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-35
DC power cord - Pin assignment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-48
DIO connector cable K-31100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-52
DIO connector cable - PIN assignment . . . . . . . . . . . . . . . . . . . . . . . . . . 4-53
Profibus-Server connector cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-60
Profibus-Server connector cable - PIN assignment . . . . . . . . . . . . . . . . 4-60
Profibus extension cables - PIN assignment. . . . . . . . . . . . . . . . . . . . . . 4-61
Profibus extension cables - PIN assignment. . . . . . . . . . . . . . . . . . . . . . 4-61
Installation of the bus connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-62
Wiring plan: CPC-41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
Wiring plan: PRA-41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5
Wiring plan: BRA-41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
Wiring plan: SIO-41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-9
Wiring plan: DIO-41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-11
Wiring plan: Line extension of the COM interface (CSA-01-0X) . . . . . . . 6-13
Wiring plan: Line extension of the protocol printer for logging (Leiser) . . 6-15
Wiring plan: Line extension of the Host interface (Leiser). . . . . . . . . . . . 6-17
Wiring Plan: Line extension E-Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-19
Wiring Plan: Line extension Sigmasys fire alarm system . . . . . . . . . . . . 6-21

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

0-1

DAKS Rel7 Hardware_TVZ.fm

List of Tables

0-2

Nur fr den internen Gebrauch

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

DAKS Rel7 Hardware_AVZ.fm


Nur fr den internen Gebrauch

List of Images
Image 2-1
Image 4-1
Image 4-2
Image 4-3
Image 4-4
Image 4-5
Image 4-6
Image 4-7
Image 4-8
Image 4-9
Image 4-10
Image 4-11
Image 4-12
Image 4-13
Image 4-14
Image 4-15
Image 4-16
Image 4-17
Image 4-18
Image 4-19
Image 4-20
Image 4-21
Image 4-22
Image 4-23
Image 4-24
Image 4-25
Image 4-26
Image 4-27
Image 4-28
Image 4-29
Image 4-30
Image 4-31
Image 4-32
Image 4-33
Image 4-34
Image 4-35
Image 4-36
Image 4-37
Bild 4-38
Image 4-39

List of Images

Overview OScAR-Pro Release 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3


Racks - Casing front - 5 slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
Racks - Casing front - with optional bus - 12 slots . . . . . . . . . . . . . . . . . . 4-3
Population option of the power supply unit: ACP-41 . . . . . . . . . . . . . . . . . 4-4
Population option of the power supply unit: DCP-41. . . . . . . . . . . . . . . . . 4-5
Population option of the power supply units: ACP-41, ACP-41. . . . . . . . . 4-5
Population options of the power supply units: DCP-41, DCP-41 . . . . . . . 4-5
Population options of the power supply units: ACP-41, DCP-41. . . . . . . . 4-6
Population options of the power supply units: DCP-41, ACP-41. . . . . . . . 4-6
Population options of bus boards for systems w. 5 or 12 slots . . . . . . . . . 4-7
Front plate ACP-41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
Front plate DCP-41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
Front plate CPC-41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14
Front plate PRA-41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16
Front plate BRA-41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-18
Front plate DSP-41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20
Front plate SIO-41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-22
Front plate DIO-41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24
Front plate AIO-41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-26
USB adapter for DCF-77 radio receiver . . . . . . . . . . . . . . . . . . . . . . . . . 4-29
AD450: DCF-77 radio receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-30
Position of DIL switches on the interface board . . . . . . . . . . . . . . . . . . . 4-32
CSA Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-34
Line extension E-Link IV, Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-35
Transmission kit for OScAR-Pro to PC/Host . . . . . . . . . . . . . . . . . . . . . . 4-37
Transmission kit for PC/Host. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-38
Transmission kit for OScAR-Pro to Printer . . . . . . . . . . . . . . . . . . . . . . . 4-39
Transmission kit for Printer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-40
DCE adapter with a local handshake . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-41
DCE adapter with remote handshake . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-42
DTE adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-43
PRN adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-44
PRT adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-45
The RJ-45 socket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-46
Converter from RS422/RS485 to RS232 . . . . . . . . . . . . . . . . . . . . . . . . 4-47
DC power cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-48
Patch cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-50
DIO connector cable K-31100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-52
RS232 data cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-55
Connector cable OScAR-Pro to CV442-1 . . . . . . . . . . . . . . . . . . . . . . . . 4-56

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

0-1

DAKS Rel7 Hardware_AVZ.fm

List of Images

Image 4-40
Image 4-41
Image 4-42
Image 4-43
Image 4-44
Image 6-1
Image 6-2
Image 6-3
Image 6-4
Image 6-5
Image 6-6
Image 6-7
Image 6-8
Image 6-9
Image 6-10
Image 6-11
Image 6-12
Image 6-13

0-2

Nur fr den internen Gebrauch

Connector cable Sigmasys to CV442-1 . . . . . . . . . . . . . . . . . . . . . . . . . . 4-57


Profibus adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-59
Profibus-Server connector cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-60
Profibus extension cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-61
Installation of the bus connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-62
Wiring plan: CPC-41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
Wiring plan: PRA-41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
Wiring plan: BRA-41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
Wiring plan: SIO-41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8
Wiring plan: DIO-41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-10
Wiring plan: Line extension of the COM interface (CSA-01-0X). . . . . . . . 6-12
Wiring plan: Line extension of the protocol printer for logging (Leiser) . . 6-14
Wiring plan: Line extension of the host interface (Leiser). . . . . . . . . . . . . 6-16
Wiring Plan: Line extension E-Link. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-18
Wiring Plan: Line extension Sigmasys fire alarm system . . . . . . . . . . . . . 6-20
Overall wiring plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-22
Modules and power supply for make contacts . . . . . . . . . . . . . . . . . . . . . 6-23
Module wiring for break contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-24

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

DAKS Rel7 Hardware_01.fm


Conventions and Operating Instructions

Conventions and Operating Instructions

Readers and qualifications


This manual is written for service engineers and technicians who need to carry out the initial
installation and start up of OScAR-Pro.
To perform the tasks described in this manual all service engineers and technicians need to be
trained on OScAR-Pro and must have a sound knowledge of telecommunication engineering.
Contents
This chapter covers the following areas:

Section 1.1, Overview of chapters

Section 1.2, Notations and symbols

Section 13, Data protection and data safety

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

1-1

DAKS Rel7 Hardware_01.fm

Conventions and Operating Instructions


Overview of chapters

1.1

Nur fr den internen Gebrauch

Overview of chapters

This document covers the following chapters:

Chapter

Description

Chapter 1, Conventions and


Operating Instructions

This chapter lists the notations and symbols that are used
throughout the manual. It also gives you helpful work instructions and provides valuable information on data protection
and data safety.

Chapter 2, Product Overview This chapter gives you an overview of OScAR-Pro Release 7,
its components and functions.
Chapter 3, Server Specifica- This chapter covers the technical specification of the OScARtion
Pro server
Chapter 4, Product Components

This chapter gives you an overview of the boards, cable cords,


adapters, line extensions and other external components

Chapter 5, Hardware Opera- This chapter contains important safety instructions and shows
tions on the OScAR-Pro Serv- you how to install the boards and other components
er
Chapter 6, Wiring plans

This chapter gives you an overview of the wiring that is needed to connect the OScAR-Pro Server with external components

Chapter 7, Declaration of
Conformity

This chapter contains the Declaration of Conformity of OScAR-Pro Release 7.

Table 1-1

1-2

Overview of chapters

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

1.2

DAKS Rel7 Hardware_01.fm


Conventions and Operating Instructions
Notations and symbols

Notations and symbols

Notations
The following definitions are used in this document:
Text

All texts from files that are described in this manual and all entries
that are added to those files appear in the non-proportional Courier typeface.

The password 123456 ...

Details and instructions in the continuous text that are of particular importance or must be heeded appear in bold print. Buttons
and menus are also output in bold print.

The file global.cfg

Files and directories are output in the non-proportional


Courier typeface.

<Place holder>

Entries and outputs, both of which may vary depending on the individual situation in which they appear, are placed in <angle
brackets> and appear in italics.

[beginning of value range All default values and all value range details from data fields are
... end of value range; de- placed in squared brackets and appear in italics. The [x] after an
fault setting] or [X]
entry option for a database field indicates that this entry option is
also the default value.
Table 1-2

Notations

Symbols
The following symbols are used in this manual:
The "i" is used to indicate additional helpful information.

The exclamation mark is used to indicate important information to which the reader
should give particular attention.
Warning
The warning sign is used to alert you to a hazardous or high risk situation. It means
that you are currently exposed to a risk situations that can cause physical injury. Before you start working with any apparatus, please be aware of the risks that may arise
in connection with the electric currents of the device and follow the standard practice
to avoid accidents.

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

1-3

DAKS Rel7 Hardware_01.fm

Conventions and Operating Instructions


Data protection and data safety

13

Nur fr den internen Gebrauch

Data protection and data safety

In order to comply with the legal provisions that apply when providing service, be it service at
the customer's site or teleservice, we strongly urge all readers to follow the below-listed rules.
This will not only help you to protect the interests and concerns of your/our customers and clients, but also to avoid adverse or unwanted repercussions and liability.
Please help ensure the full protection and safety of data by being aware of these issues
as you work:

Always make sure that only authorized persons have access to your client and customer
data.

Assign passwords whenever you can and do not grant unauthorized persons access to
your passwords, for example by writing them down.

Always make sure that no unauthorized persons can process (e. g. save, edit, transmit,
block, or delete) or utilize customer data in any way.

Always make sure that no unauthorized persons have access to data storage mediums, for
example to backup disks or logging printouts. This applies both to service work provided
at the customer direct and to the storage and transport of data mediums.

Always make sure that every data storage medium that is no longer needed is properly and
fully destroyed. Also be careful not to leave behind any papers that could become openly
accessible to others.

We urge all readers to work together closely with the clients' contact persons. This will
help to build trust and at the same time reduce your own workload.

1-4

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

DAKS Rel7 Hardware_02.fm


Product Overview

Product Overview

The central component of every OScAR-Pro system (see Image 2-1) is the OScAR-Pro server.
It is this server that realizes all switching and transmission tasks.
The OScAR-Pro server supports both the classic TDM telephony and voice over IP (VoIP):

TDM
In TDM telephony networks, the OScAR-Pro server is connected digitally to one or more
PBXs like a sub-system with an own dial plan. Depending on the bus boards that are installed, the connection can be realized with up to 480 channels (S0, E1 or S2M, T1).
In combination with HiPath/OpenScape, the Siemens network protocol CorNet-NQ is used
as D-channel protocol. Especially in combination with HiPath/OpenScape 4000, this
makes it possible for OScAR-Pro server to utilize, even worldwide, all HiPath/OpenScapefeatures that are available throughout the network, for example alarm and emergency calls,
forced release and display control.
The network protocols QSIG, DSS1 and NI2 are used in combination with any PBX and
public network providers.

VoIP
Here the OScAR-Pro server is connected to the TCP/IP network and acts like an SIP gateway with up to 60 channels at maximum data rates of 1000 Mbit/s.
The network communications protocol that is used is SIP (Session Initiation Protocol) in
combination with the standard G.711 for voice encoding, whereas RTP (Real-Time Transport Protocol) is used to log the data transport, and SDP (Session Description Protocol) is
used as session description protocol.

The OScAR-Pro server has 2 slots for the power supply. The slots can be used in any combination to connect one or two PSUs:

ACP-41
Power supply voltage 115 or 230 V AC (start of value range)

DCP-41
48 V DC from the 48V telephone battery of the PBX system

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

2-1

DAKS Rel7 Hardware_02.fm

Product Overview

Nur fr den internen Gebrauch

The bus board CPC-41 serves as the central control computer of the OScAR-Pro server:

CPC-41
The bus board CPC-41 is used for all central processes of the OScAR-Pro server. Here,
the following interfaces can be utilized:
2x Ethernet 10-/100-/1000Base-T for the IP connection to the LAN
1x RS232 interface for the basic settings and external servicing and maintenance of
the OScAR-Pro server
2x USB2.0-Host to link up:

System printer for system- and process messages

DCF-77 radio clock receiver via adapter DUA-41 for the synchronization with the
DCF-77 standard time

The following bus boards are used to connect TDM channels:

PRA-41
Primary-Rate Adapter for E1 (S2M) with max. 4x30 B-channels, or T1 with max. 4x23 Bchannels.

BRA-41
Basic-Rate-Adapter for S0 with max. 4x2 B-channels.
Different B-channel protocols can be used for the individual interfaces.

The OScAR-Pro server can be equipped with the following additional bus boards:

DSP-41
The DSP bus board has the following functions:
Switching network and conferences
Storage and playback of voice announcements
Encode and decode the payload for VoIP (e.g. RTP data)
Generate the central timing for TDM

AIO-41
Audio frequency interface to couple analog audio signals in and out (4 x IN, 4 x OUT)

DIO-41
16 digital inputs, electrically isolated with internal or external feed
8 digital outputs, isolated electrically or among one another
1 relay output

2-2

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

DAKS Rel7 Hardware_02.fm


Product Overview

SIO-41
Bus board with 4 serial interfaces (RS232, RS422, RS485), each electrically isolated from
one another and from the housing to connect external systems:
Nurse call system ESPA 4.4.4 via RS232 or RS422
Profibus-DP ber RS485
Fire alarm system, central building control system via RS232 or RS422
Send SMS messages to GSM handsets using an analog/ISDN or radio modem
Other Host systems via RS232 or RS422
Different protocols can be used for the individual interfaces.

Image 2-1 Overview OScAR-Pro Release 7

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

2-3

DAKS Rel7 Hardware_02.fm

Product Overview

2-4

Nur fr den internen Gebrauch

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

DAKS Rel7 Hardware_03.fm


Server Specification

Nur fr den internen Gebrauch

Server Specification

The table below offers a detailed overview of the OScAR-Pro server properties:
Description

Value

Dimensions

height
width
depth

150 mm
449 mm
282 mm

Weight

max. configuration

7500 g

Electric power supply

AC power supply
Voltage range
Electric current requirement
DC power supply
Voltage range
Electric current requirement

Air cooling

100 V - 240 V 50/60 Hz


0.55 A - 0.39 A
36 V - 60 V
1.3 A- 0.8 A

Convective air cooling

Operating temperature 5 C ... 35 C


Humidity

max. 95%, non-condensing

MTBF

> 400,000 h (over a 5-year period under report)

System bus

32/64 bit cPCI bus


3U

cPCI Standards

System expansions

cPCI bus with 5 slots


cPCI bus with 12 slots

Table 3-1

PICMG 2.0 Compact PCI


PICMG 2.1 Hot Swap
PICMG 2.6 Bridging
PICMG 2.10 Keying
PICMG 2.11 Power Interface

System specification of the OScAR-Pro server

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

3-1

DAKS Rel7 Hardware_03.fm

Server Specification

Description

Nur fr den internen Gebrauch

Value

Certifications/Declara- EN 55022
tions of conformity
EN 55024
EN 61000-3-2
EN 61000-3-3
EN 60950-1
IEC 60950-1
FCC Part 15 B
CE marking
CB Scheme
CB Reports
Table 3-1

3-2

System specification of the OScAR-Pro server

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

DAKS Rel7 Hardware_04.fm


Product Components

Product Components
Warning
All external components that are connected to the OScAR-Pro server must meet and
comply with the pertinent legal provisions that are currently in force in the country in
which they are operated.

Overview
This chapter offers a detailed overview of the hardware properties of the different product components.
Contents
4.1 Subrack
4.2 Boards
4.2.1 General information
4.2.2 ACP-41: AC Power supply
4.2.3 DCP-41: DC Power supply
4.2.4 CPC-41: Controller board
4.2.5 PRA-41: Primary-rate adapter (E1/T1)
4.2.6 BRA-41: Basic-rate adapter (S0)
4.2.7 DSP-41: Digital signal processor
4.2.8 SIO-41: Serial interfaces
4.2.9 DIO-41: Digital inputs and outputs
4.2.10 AIO-41: Audio interface
4.3 CompactFlash card
4.4 Add ons
4.4.1 USB adapter for DCF-77 radio receiver
4.4.2 DCF-77 radio receiver
4.4.3 Printer
4.4.4 USB/RS232 interface
4.5 Line extensions
4.5.1 CSA-Converter
4.5.2 E-Link: Line extension modem
4.5.3 Dialing modem (analog)
4.5.4 Dialing modem (digital)
4.5.5 GSM modem
4.5.6 Transmission kit for OScAR-Pro to PC/Host
4.5.7 Transmission kit for PC/Host
4.5.8 Transmission kit for OScAR-Pro to Printer
4.5.9 Transmission kit for Printer

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-1

DAKS Rel7 Hardware_04.fm

Product Components

Nur fr den internen Gebrauch

4.6 General adapters


4.6.1 DCE adapter
4.6.2 DTE adapter
4.6.3 PRN adapter
4.6.4 PRT adapter
4.6.5 RJ45 socket
4.6.6 Patch field
4.6.7 Converter from RS422/RS485 to RS232
4.7 General cable cords
4.7.1 DC power cord
4.7.2 AC connector cable
4.7.3 USB cable cord
4.7.4 Patch cable
4.7.5 Connector cable for digital inputs and outputs
4.7.6 RS232 data cable
4.7.7 Connector cable OScAR-Pro to CV422-1
4.7.8 Connector cable Sigmasys to CV422-1
4.8 Profibus-DP with ET 200
4.8.1 Input module
4.8.2 Terminal block
4.8.3 Electric power supply
4.8.4 Profibus adapter
4.8.5 Profibus-Server connector cable
4.8.6 Profibus extension cables
4.8.7 Installation of the bus connector
4.8.8 Top-hat rail for Profibus modules

4-2

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

4.1

DAKS Rel7 Hardware_04.fm


Product Components
Subrack

Subrack

Properties:

Shielded metal sub-rack

19 construction

Height: 3U = 3HU (U = units, HU = height units)

For tabletop operation with feet, or mounted in a 19" rack (convertible)

Image 4-1

Racks - Casing front - 5 slots

Image 4-2

Racks - Casing front - with optional bus - 12 slots

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-3

DAKS Rel7 Hardware_04.fm

Product Components
Boards

4.2

Nur fr den internen Gebrauch

Boards
For further details on how to install the boards please see Chapter 5, Hardware Operations on the OScAR-Pro Server.

4.2.1

General information

4.2.1.1 Power supply boards


You can power supply your system with one or two PSUs of the types ACP-41 (see Section
4.2.2 ACP-41: AC Power supply) or DCP-41 (see Section 4.2.3 DCP-41: DC Power supply).
The PSUs can be inserted in slots P1 and P2. Table 4-1 and Image 4-3 show the different ways
and combinations in which the PSUs can be mounted. PSUs that are used in parallel operation
work in load-sharing (power distribution)
Population option

Slot P1

Slot P2

Image 4-3

ACP-41

Image 4-4

DCP-41

Image 4-5

ACP-41

ACP-41

Image 4-6

DCP-41

DCP-41

Image 4-7

ACP-41

DCP-41

Image 4-8

DCP-41

ACP-41

Table 4-1

Population options of the power supply units: ACP-41 and DCP-41

Image 4-3

Population option of the power supply unit: ACP-41

4-4

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

DAKS Rel7 Hardware_04.fm


Product Components
Boards

Image 4-4

Population option of the power supply unit: DCP-41

Image 4-5

Population option of the power supply units: ACP-41, ACP-41

Image 4-6

Population options of the power supply units: DCP-41, DCP-41

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-5

DAKS Rel7 Hardware_04.fm

Product Components
Boards

Nur fr den internen Gebrauch

Image 4-7

Population options of the power supply units: ACP-41, DCP-41

Image 4-8

Population options of the power supply units: DCP-41, ACP-41

4-6

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

4.2.1.2

DAKS Rel7 Hardware_04.fm


Product Components
Boards

Bus boards

Please follow the below instructions when selecting a slot to install a bus board:

The slot S1 must always be populated with a CPC-41 bus board.

Even if the OScAR-Pro server is operated with a bus expansion the S2 slot must be either
populated with a DSP-41 or SIO-41 bus board, or remain vacant.

The remaining bus boards (PRA-41, BRA-41, DIO-41, SIO-41, AIO-41) can be used in any
combination on the slots S3 - S5 and, in combination with an already installed bus expansion, also on the slots S6 - S12.

Image 4-9

Population options of bus boards for systems w. 5 or 12 slots

Please note that the bus boards have no jumpers, switches or other components that
require modification by the user. Also, the entire bus board configuration is done via
software only.

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-7

DAKS Rel7 Hardware_04.fm

Product Components
Boards

4.2.1.3

Nur fr den internen Gebrauch

Status indicator for bus boards

This status is indicated in form of a 3-color light-emitting diode (red, yellow, green). The belowlisted attributes apply to all bus boards:

OFF
Possible reasons why a status indicator is not lit:
No power supply
Bus board inserted wrong
Electronic fuse ON

Red
Reset

Red blinking
Internal error

Yellow
Booting

Yellow blinking
Basic system ready,
For CPC-41: Connection via VCON possible (see Configuration
Manual)
For all other bus boards: Operating system active and operating, application or other bus board software inactive

Green-red blinking
OScAR-Pro server not enabled

Green-yellow blinking Application activated, working data ot available

Green
Ready-to-operate

Green blinking
Ready-to-operate, only CPC-41

Green fast blinking


Active and operating

If for any reason the electronic safety fuse of a bus board is triggered, causing the
bus board to shut off as a consequence (status indicator: OFF), please make sure
that the OScAR-Pro server is disconnected from all power supplies (see Section
4.2.2 ACP-41: AC Power supply and/or Section 4.2.3 DCP-41: DC Power supply),
and remains powered off for at least 5 seconds before it is powered up again.

4-8

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

4.2.1.4

DAKS Rel7 Hardware_04.fm


Product Components
Boards

Status indicator Power supply boards

This status is indicated in form of a 3-color light-emitting diode (red, yellow, green). The following attributes are the same for all PSUs:

OFF
Possible reasons why a status indicator is not lit:
No power supply
Fuse ON

Yellow
Ready-to-operate, Load-Sharing-Operation (power distribution)
OFF

Green
Ready-to-operate, load-sharing-operation (power distribution) activated, provided 2 power supplies are mounted

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-9

DAKS Rel7 Hardware_04.fm

Product Components
Boards

4.2.2

ACP-41: AC Power supply

Order number:

Image 4-10

4-10

Nur fr den internen Gebrauch

TNK:ACP-41-0X

Front plate ACP-41

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

DAKS Rel7 Hardware_04.fm


Product Components
Boards

Element

Description

Status

see Section 4.2.1.4 Status indicator Power supply boards

ON/OFF

ON/OFF switch to activate/deactivate the power supply

Power

IEC jack for an IEC inlet connector for non-heating apparatus to connect the PSU to the mains power supply
Technical details:
Input voltage 100 ... 240 V AC

Table 4-2

Connectors and outputs of the front plate ACP-41

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-11

DAKS Rel7 Hardware_04.fm

Product Components
Boards

4.2.3

DCP-41: DC Power supply

Order number:

Image 4-11

4-12

Nur fr den internen Gebrauch

TNK:DCP-41-0X

Front plate DCP-41

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

DAKS Rel7 Hardware_04.fm


Product Components
Boards

Element

Description

Status

see Section 4.2.1.4 Status indicator Power supply boards

ON/OFF

ON/OFF switch to activate/deactivate the power supply

Power

Connector jack to connect the PSU to the 48V DC power supply.


Technical details:
Input voltage 36 ... 60 V DC
Connector pin assignment:
A1
- DC
A2
Earth
A3
+ DC

Table 4-3

Connectors and outputs of the front plate DCP-41

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-13

DAKS Rel7 Hardware_04.fm

Product Components
Boards

4.2.4

CPC-41: Controller board

Order number:

Image 4-12

4-14

Nur fr den internen Gebrauch

TNK:CPC-41-0X

Front plate CPC-41

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

DAKS Rel7 Hardware_04.fm


Product Components
Boards

Nur fr den internen Gebrauch

Element

Description

Reset

Reset button to reset all installed boards with the exception of the
power supply boards (ACP-41, DCP-41)

Status

see Section 4.2.1.3 Status indicator for bus boards

RS232

RS232 interface with RJ45 jack:


Service interface for the basic OScAR-Pro server settings

USB A
USB B

Pin 1:
Pin 2:
Pin 3:
Pin 4:
Pin 5:
Pin 6:
Pin 7:
Pin 8:

n. c.
RTS
GND
TxD
RxD
n. c.
CTS
n. c.

Pin 1:
Pin 2:
Pin 3:
Pin 4:

VBus
DD+
GND

USB 2.0 interface:

Ethernet interface A, B
ETH A
ETH B

RJ45 jack for connectivity to the LAN (10-,100-,1000Base-T) via


patch or cross-patch cable

Pin 1:
Pin 2:
Pin 3:
Pin 4:
Pin 5:
Pin 6:
Pin 7:
Pin 8:

Pin name Used for


10-/100Base T
MX0+
Tx+
MX0TxMX1+
Rx+
MX2+
MX2not used
MX1RxMX3+
not used
MX3not used

LED B1

Activity of the Ethernet interface

LED B2

Physical contact is established to the LAN (link)

LED A1

see LED B1

LED A2

see LED B2

Table 4-4

Used for
1000Base T
BI_DA+
BI_DABI_DB+
not usedBI_DC+
BI_DCBI_DBBI_DD+
BI_DD-

Connectors and outputs of the front plate CPC-41

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-15

DAKS Rel7 Hardware_04.fm

Product Components
Boards

4.2.5

PRA-41: Primary-rate adapter (E1/T1)

Order number:

Image 4-13

4-16

Nur fr den internen Gebrauch

TNK:PRA-41-0X

Front plate PRA-41

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

DAKS Rel7 Hardware_04.fm


Product Components
Boards

Nur fr den internen Gebrauch

Element

Description

Status

see Section 4.2.1.3 Status indicator for bus boards

E1/T1 Interface A, B, C, D
E1/T1 A
E1/T1 B
E1/T1 C
E1/T1 D

RJ45 socket for connectivity to the PBX.


Technical details:
Input resistance E1
Input resistance T1

120
100
Pin 1:
Pin 2:
Pin 3:
Pin 4:
Pin 5:
Pin 6:
Pin 7:
Pin 8:

LED A1

Status indicator:
OFF
red
yellow
green
green blinking

Rx+
Rxn. c.
Tx+
Txn. c.
n. c.
n. c.

Interface closed
Layer 1 inactive
Layer 1 active, Layer 2 inactive
Layer 1 and Layer 2 active
Layer 1 inactive, Layer 2 active

LED A2

Status indicator:
OFF
E1/T1 closed
yellow
Layer 3 active (all B-channels occupied)
green
Layer 3 active (at least 1 B channel occupied)

LED B1

see LED A1

LED B2

see LED A2

LED C1

see LED A1

LED C2

see LED A2

LED D1

see LED A1

LED D2

see LED A2

Table 4-5

Connectors and outputs of the front plate PRA-41

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-17

DAKS Rel7 Hardware_04.fm

Product Components
Boards

4.2.6

BRA-41: Basic-rate adapter (S0)

Order number:

Image 4-14

4-18

Nur fr den internen Gebrauch

TNK:BRA-41-0X

Front plate BRA-41

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

DAKS Rel7 Hardware_04.fm


Product Components
Boards

Nur fr den internen Gebrauch

Element

Description

Status

see Section 4.2.1.3 Status indicator for bus boards

S0 interface A, B, C, D
S0 A
S0 B
S0 C
S0 D

RJ45 jack for connectivity to the PBX via patch cable

LED A1

Status indicator:
OFF
red
yellow
green
green blinking

Technical details:
Input resistance S0

100
Pin 1:
Pin 2:
Pin 3:
Pin 4:
Pin 5:
Pin 6:
Pin 7:
Pin 8:

n. c.
n. c.
Tx+
RxRx+
Txn. c.
n. c.

Interface closed
Layer 1 inactive
Layer 1 active, Layer 2 inactive
Layer 1 and Layer 2 active
Layer 1 inactive, Layer 2 active

LED A2

Status indicator:
OFFs
S0 closed
yellow
Layer 3 active (all B-channels occupied)
green
Layer 3 active (at least 1 B channel occupied)

LED B1

see LED A1

LED B2

see LED A2

LED C1

see LED A1

LED C2

see LED A2

LED D1

see LED A1

LED D2

see LED A2

Table 4-6

Connectors and outputs of the front plate BRA-41

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-19

DAKS Rel7 Hardware_04.fm

Product Components
Boards

4.2.7

DSP-41: Digital signal processor

Order number:

Image 4-15

4-20

Nur fr den internen Gebrauch

TNK:DSP-41-0X

Front plate DSP-41

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

DAKS Rel7 Hardware_04.fm


Product Components
Boards

Element

Description

Status

see Section 4.2.1.3 Status indicator for bus boards

LED 1

Status indicator:
Universal LEDs
This function depends on the application that is currently active.
Possible colors are: red, yellow, green

LED 2
LED 3
Table 4-7

Outputs of the front plate DSP-41

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-21

DAKS Rel7 Hardware_04.fm

Product Components
Boards

4.2.8

SIO-41: Serial interfaces

Order number:

Image 4-16

4-22

Nur fr den internen Gebrauch

TNK:SIO-41-0X

Front plate SIO-41

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

DAKS Rel7 Hardware_04.fm


Product Components
Boards

Nur fr den internen Gebrauch

Element

Description

Status

see Section 4.2.1.3 Status indicator for bus boards

Communication interface A, B, C, D
COM A
COM B
COM C
COM D

RJ45 socket for connectivity to external systems (e.g. a nurse call


system):
RS232
RS422
RS485
The interfaces COM A, B, C and D are electrically isolated from one
another and from the system ground.
Pin 1:
Pin 2:
Pin 3:
Pin 4:
Pin 5:
Pin 6:
Pin 7:
Pin 8:

RS232
n. c.
RTS
GND
TxD
RxD
n. c.
CTS
DTR

RS422
n. c.
Tx+/Y
GND
Tx-/Z
Rx+/A
n. c.
Rx-/B
n. c.

LED A1

Status indicator:
Universal LED
This function depends on the application that is currently active.
Possible colors are: red, yellow, green
Standard function: TxD (green for data transfer)

LED A2

Status indicator:
Universal LED
This function depends on the application that is currently active.
Possible colors are: red, yellow, green
Standard function: RxD (green for data transfer)

LED B1

see LED A1

LED B2

see LED B2

LED C1

see LED A1

LED C2

see LED B2

LED D1

see LED A1

LED D2

see LED B2

Table 4-8

Connectors and outputs of the front plate SIO-41

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-23

DAKS Rel7 Hardware_04.fm

Product Components
Boards

4.2.9

DIO-41: Digital inputs and outputs

Order number:

Image 4-17

4-24

Nur fr den internen Gebrauch

TNK:DIO-41-0X

Front plate DIO-41

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

DAKS Rel7 Hardware_04.fm


Product Components
Boards

Element

Description

Status

see Section 4.2.1.3 Status indicator for bus boards

Digital I/O

37-Pin Sub-D jack to connect different inputs and outputs via the DIO
connector cable cord K-31100 (see Section 4.7.5 Connector cable
for digital inputs and outputs)
16 electrically isolated inputs
Technical details:
Internal feeding possible to connect contacts directly
External power supply:
10.5 .. 60V DC
Uin
Rin
15 k
8 electrically isolated outputs, also isolated from each other
Technical details:
Umax
60 V DC
Imax
0.1 A
RON
11
1 Relay output
Technical details:
60 V DC
Umax
Imax
1A
Pmax
30 W

Table 4-9

Connectors and outputs of the front plate DIO-41

Pin assignment for Digital I/O:


see Section 4.7.5 Connector cable for digital inputs and outputs

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-25

DAKS Rel7 Hardware_04.fm

Product Components
Boards

Nur fr den internen Gebrauch

4.2.10 AIO-41: Audio interface


Order number:

Image 4-18

4-26

TNK:AIO-41-0X

Front plate AIO-41

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

DAKS Rel7 Hardware_04.fm


Product Components
Boards

Nur fr den internen Gebrauch

Element

Description

Status

see Section 4.2.1.3 Status indicator for bus boards

LED 1

Universal LEDs
This function depends on the application that is currently active.
Possible colors are: red, yellow, green

IN 1
IN 2
IN 3
IN 4

Audio input
The level settings are configured via software.
Technical details:
Connection
Stereo jack socket 3.5 mm
Input voltage: Uin = 775 mV eff. (0 dBm)
Input resistance:
Rin = 6 k
Pin 1:
Pin 2:
Pin 3:

OUT 1
OUT 2
OUT 3
OUT 4

IN 3, IN 4
IN 3
IN 4
GND

Audio output
The level settings are configured via software.
Technical details:
Connection
Stereo jack socket 3.5 mm
Output voltage:
Uout = 775 mV eff. (0 dBm)
Output resistance:Rout = 600
Pin 1:
Pin 2:
Pin 3:

Table 4-10

IN 1, IN 2
IN 1
IN 2
GND

OUT 1, OUT 2
OUT 1
OUT 2
GND

OUT 3, OUT 4
OUT 3
OUT 4
GND

Connectors and outputs of the front plate AIO-41

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-27

DAKS Rel7 Hardware_04.fm

Product Components
CompactFlash card

4.3

Nur fr den internen Gebrauch

CompactFlash card

Order number:

TNK:CF-1G-01

Function:

The CompactFlash card is a mass storage device format in the OScAR-Pro server. It is used to store all non-volatile data that is needed by the OScAR-Pro server to operate properly, such as data on
the operating system, driver, license details, applications and announcements.

Technical details:

Storage capacity:

1GB

Note
The CompactFlash card TNK:CF-1G-01 cannot be replaced with a commercially
available CompactFlash card.

4-28

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

DAKS Rel7 Hardware_04.fm


Product Components
Add ons

Nur fr den internen Gebrauch

4.4

Add ons

4.4.1

USB adapter for DCF-77 radio receiver

Order number:

TNK:DUA-41-0X

Function:

Adapter to connect the DCF-77 radio receiver (AD 450) via USB

Image 4-19

USB adapter for DCF-77 radio receiver

Element

Description

Status indicator:
OFF
ON intermittently
OFF intermittently

No power supply from USB


Initializing
Time receipt synchronous

USB connector to link up the DUA-41 module with the USB port at the
CPC-41 controller of the OScAR-Pro server

Port for the DCF-77 receiver unit AD 450

Table 4-11

USB adapter for DCF-77 radio receiver

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-29

DAKS Rel7 Hardware_04.fm

Product Components
Add ons

4.4.2

Nur fr den internen Gebrauch

DCF-77 radio receiver

Order number:

TNK:AD450

Function:

Radio receiver to synchronize the OScAR-Pro server with the official time in the Germany time zone

Technical details:

Measurements:

Cable length:
Cable extension:

Image 4-20

Length 65 mm
Depth 35 mm
Height 90 mm (with connection plate)
10 m
Max. 200 m
Cable properties: 2-wire twisted pair cable cord, minimum cross
section 2 x 0.25 mm

AD450: DCF-77 radio receiver

Element

Description

Status indicator:
OFF
No power supply from the connection cable
Blinking 1x per s Good radio reception
Flickering
Interference of the radio reception

Connection cable open at both ends for connectivity to DUA-41(see


Section 4.4.1 USB adapter for DCF-77 radio receiver)

Table 4-12

4-30

AD450: DCF-77 radio receiver

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

DAKS Rel7 Hardware_04.fm


Product Components
Add ons

Please follow the below instructions when you install the DCF-77 radio receiver:

Mount the apparatus as high up as possible and not in buildings with exterior walls that are
highly insulated and shielded, nor in buildings with a metallic roof construction.

Minimum distance from sources of interference 2 - 3 m.

Mount the reception housing horizontal.

If necessary, shorten the connection cable to avoid an antenna effect.

After the connection is made and the receiver is adjusted, wait 30 seconds before assessing the radio reception (see Table 4-12, Status indicator).

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-31

DAKS Rel7 Hardware_04.fm

Product Components
Add ons

4.4.3

Nur fr den internen Gebrauch

Printer

Order number:

TNK:LP-OML280

Function:

Protocol printer for logging, with direct connectivity to the OScARPro server

For further details on the OKI Microline 280 please see the installation CDs included
in the printer delivery package.
The printer automatically detects if it is running on a a serial or USB interface.
The DIL switches covered below only have relevance if the printer is operated on one of the
serial interfaces. Please make sure the DIL switches on the interface board are configured as
described in Image 4-21 or Table 4-13 (see Printer Manual).

Image 4-21

Element

Position of DIL switches on the interface board

Def. settg.

Description

ON

No parity

ON

ON

Data format 8 bits

ON

Busy/ready report

ON

Normal printer mode, no test mode

ON

ON

ON

SW1

Table 4-13

4-32

Busy signal via Pin 20

Position of DIL switches on the interface board.

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

DAKS Rel7 Hardware_04.fm


Product Components
Add ons

Nur fr den internen Gebrauch

Element

Def. settg.

Description

OFF

Transmission rate 9600 baud

ON

ON

ON

Printer spooler in system, printer operating in handshaking


mode

OFF

Busy signal active when space for only 256 characters remains in buffer

OFF

Busy timing 2

ON

do not change

OFF

SW2

Table 4-13

4.4.4

Position of DIL switches on the interface board.

USB/RS232 interface

Order number:

TNK:USB/RS232-0X

Function:

Adapter to convert a RS232 interface to a USB interface for connectivity to a CPC-41

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-33

DAKS Rel7 Hardware_04.fm

Product Components
Line extensions

Nur fr den internen Gebrauch

4.5

Line extensions

4.5.1

CSA-Converter

Order number:

TNK:CSA-01-0X

Function:

To convert an RS-422 interface into an RS-232 interface (see Section 6.6 Line extension of the COM interface (CSA-01-0X)).

Image 4-22

CSA Adapter

Pin assignment RS422: Pin 1:


Pin 2:
Pin 3:
Pin 4:
Pin 5:
Pin 6:
Pin 7:
Pin 8:

n. c.
Rx+/A
GND
Rx-/B
Tx+/Y
n. c.
Tx-/Z
n. c.

Pin assignment RS232: Pin 1:


Pin 2:
Pin 3:
Pin 4:
Pin 5:
Pin 6:
Pin 7:
Pin 8:

DSR
RTS
GND
TxD
RxD
DCD
CTS
DTR

The CSA adapter is powered through the RS232 connection and needs no other
electric power supply.

4-34

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

4.5.2

DAKS Rel7 Hardware_04.fm


Product Components
Line extensions

E-Link: Line extension modem

Order number:

TNK:E-LINK4-T

Function:

Line extension for a RS232 interface (SIO-41 or CPC-41) to connect


to a Host, PC or printer

The following settings must be made for the E-Link 4 to operate correctly (see User Manual ELink IV).

Image 4-23

Line extension E-Link IV, Settings

Element

Switch mode

SC1

Pos. 3

SC2

Pos. 7

SC3

Pos. 3: Master
Pos. 2: Slave

SC4

Pos. D

SC5

Pos. 0

Table 4-14

Line extension E-Link IV, Settings

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-35

DAKS Rel7 Hardware_04.fm

Product Components
Line extensions

Nur fr den internen Gebrauch

Element

Switch mode

S1

Switch 1 = OFF
Switch 2 = OFF
Switch 3 = OFF
Switch 4 = OFF
Switch 5 = ON
Switch 6 = ON
Switch 7 = ON
Switch 8 = OFF

Table 4-14

4.5.3

Line extension E-Link IV, Settings

Dialing modem (analog)

Order number: TNK:AMOD56k


Function:

Remote maintenance of the OScAR-Pro server via dialing modem

For further details on how to use the dialing modem please see the User Manual.

4.5.4

Dialing modem (digital)

Order number:

TNK:DMOD56k

Function:

Remote maintenance of the OScAR-Pro server via dialing modem

For further details on how to use the dialing modem please see the User Manual.

4.5.5

GSM modem

Order number:

TNK:FM-TC35I

Function:

Dispatch of SMS messages via GSM modem

For further details on how to use the dialing modem please see the User Manual.

4-36

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

4.5.6

DAKS Rel7 Hardware_04.fm


Product Components
Line extensions

Transmission kit for OScAR-Pro to PC/Host

Order number:

TNK:V2X-90-WPZ105

Function:

Connection on the OScAR-Pro side to link-up a PC or Host to a serial interface of the OScAR-Pro server (SIO-41) with a line extension

Technical details:

Cable length:

Image 4-24

10 m

Transmission kit for OScAR-Pro to PC/Host

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-37

DAKS Rel7 Hardware_04.fm

Product Components
Line extensions

4.5.7

Nur fr den internen Gebrauch

Transmission kit for PC/Host

Order number:

TNK:VX2-09-WPZ105

Function:

Connection on the side of the PC or Host to link-up to a serial interface of the OScAR-Pro server (SIO-41) with a line extension

Technical details:

Cable length:

Image 4-25

4-38

5m

Transmission kit for PC/Host

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

4.5.8

DAKS Rel7 Hardware_04.fm


Product Components
Line extensions

Transmission kit for OScAR-Pro to Printer

Order number:

TNK:V2X-90-WPZ104

Function:

Connection on the OScAR-Pro side to link-up a printer with a line


extension, with the printer being connected to the OScAR-Pro server via USB/RS232 interface (see Section 4.4.4 USB/RS232 interface).

Technical details:

Cable length:

Image 4-26

10 m

Transmission kit for OScAR-Pro to Printer

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-39

DAKS Rel7 Hardware_04.fm

Product Components
Line extensions

4.5.9

Nur fr den internen Gebrauch

Transmission kit for Printer

Order number:

TNK:VX2-WPZ104

Function:

Connection on the printer side to link-up a printer with a line extension, with the printer being connected to the OScAR-Pro server via
USB/RS232 interface (see Section 4.4.4 USB/RS232 interface).

Technical details:

Cable length:

Image 4-27

4-40

5m

Transmission kit for Printer

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

4.6

General adapters

4.6.1

DCE adapter

DAKS Rel7 Hardware_04.fm


Product Components
General adapters

4.6.1.1 DCE-01
Order number:

TNK:A-DCE-01

Function:

Adapter to convert an RJ45 jack to a SUB D-09-F jack to connect


the OScAR-Pro server to a DTE (e.g. a PC, see Chapter 6, Wiring
plans), with a local handshake.

Image 4-28

DCE adapter with a local handshake

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-41

DAKS Rel7 Hardware_04.fm

Product Components
General adapters

4.6.1.2

Nur fr den internen Gebrauch

DCE-02

Order number:

TNK:A-DCE-02

Function:

Adapter to convert an RJ45 jack to a SUB D-09-F jack to connect


the OScAR-Pro server to a DTE (e.g. a PC, see Chapter 6, Wiring
plans), with a remote handshake

Image 4-29

4-42

DCE adapter with remote handshake

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

4.6.2

DAKS Rel7 Hardware_04.fm


Product Components
General adapters

DTE adapter

Order number:

TNK:A-DTE-0X

Function:

Adapter to convert an RJ45 jack to a SUB D-09-M jack to connect


the OScAR-Pro server to a DCE (for example to a modem)

Image 4-30

DTE adapter

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-43

DAKS Rel7 Hardware_04.fm

Product Components
General adapters

4.6.3

Nur fr den internen Gebrauch

PRN adapter

Order number:

TNK:A-PRN-0X

Function:

Adapter to convert an RJ45 jack to a SUB D-15-M jack to connect


the OScAR-Pro server to a Siemens PBX (HiPath/OpenScape) via
the PRA-41 (see Section 4.2.5 PRA-41: Primary-rate adapter (E1/
T1), Section 6.2 PRA-41)

Image 4-31

4-44

PRN adapter

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

4.6.4

DAKS Rel7 Hardware_04.fm


Product Components
General adapters

PRT adapter

Order number:

TNK:A-PRT-0X

Function:

Adapter to convert an RJ45 jack to a SUB D-15-M jack to connect


the OScAR-Pro sever to a Siemens PBX (HiPath/OpenScape) via
the PRA-41 (see Section 4.2.5 PRA-41: Primary-rate adapter (E1/
T1), Section 6.2 PRA-41), with the help of a Siemens S2M cable
cord 530267-Z88-A100.

Image 4-32

PRT adapter

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-45

DAKS Rel7 Hardware_04.fm

Product Components
General adapters

4.6.5

Nur fr den internen Gebrauch

RJ45 socket

Order number:

TNK:UAE/8/8/8AP

Function:

Link-up external components to the OScAR-Pro server

The RJ45 socket can be used for the following functions:

To connect a BRA-41 to a PBX (see Section 6.3 BRA-41)

As a line extension for serial interfaces (see: Section 6.6 Line extension of the COM interface (CSA-01-0X), Section 6.7 Line extension of the Protocol printer for logging (Leiser),
Section 6.8 Line extension of the Host interface (Leiser), Section 6.9 Line extension via
E-Link)
The Pin assignment of the RJ45 socket connectors results from the interface to which it is connected.

Image 4-33

4.6.6

The RJ-45 socket

Patch field

Order number:

not available

Function:

Link-up of external components to the OScAR-Pro server

The patch field can be used analogous to the RJ45 jack (see Section 4.6.5 RJ45 socket).

4-46

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

4.6.7

DAKS Rel7 Hardware_04.fm


Product Components
General adapters

Converter from RS422/RS485 to RS232

Order number:

TNK:CV422-1

Function:

Physical conversion of a RS422 signal to a RS232 signal. The


CV422-1 is used to link-up a remote Sigmasys fire alarm system
(see Section 6.10 Line extension Sigmasys fire alarm system).

Technical details:

Power supply

Power consumption

Image 4-34

12 .. 24 VAC/DC
150 mA at 12 VDC

Converter from RS422/RS485 to RS232

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-47

DAKS Rel7 Hardware_04.fm

Product Components
General cable cords

Nur fr den internen Gebrauch

4.7

General cable cords

4.7.1

DC power cord

Order number:

TNK:K-51001-0600

Function:

DC connector cable for DCP-41

Technical details:

Length

6m

Image 4-35

DC power cord

Pin assignment
PIN

Function

Color

A1

-DC

blue

A2

Earth

green-yellow

A3

+DC

brown

Table 4-15

4-48

DC power cord - Pin assignment

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

4.7.2

AC connector cable

Order number:

TNK:K-AC-D-0180

Function:

AC connector cable for ACP-41

Technical details:

Length

Connection:

1.80 m
Schuko safety plug

4.7.3

DAKS Rel7 Hardware_04.fm


Product Components
General cable cords

USB cable cord

Order number:

TNK:K-USBAB-0300

Function:

Cable cord to connect the following components:


Printer
DCF-77 receiver unit via DUA-41

Technical details:

Length

Connection:

3.00 m
Plug type A/B

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-49

DAKS Rel7 Hardware_04.fm

Product Components
General cable cords

4.7.4

Nur fr den internen Gebrauch

Patch cable

Order number:

TNK:K-CAT6-0300

Function:

Connector cable to connect different interfaces (LAN, S0, S2M,


RS232, RS422, Profibus)

Technical details:

Length

Category:

PIN assignment

Image 4-36

4-50

3.00 m
CAT6
in keeping with EIA/TIA T568A or EIA/TIA T568B, respectively

Patch cable

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

4.7.5

DAKS Rel7 Hardware_04.fm


Product Components
General cable cords

Connector cable for digital inputs and outputs

Order number:

TNK:K-31100-xxxx

Function:

Link-up of the DIO-41 to connect digital inputs and outputs

Technical details:

Length:

12 m - 25 m, standard length = 6 m

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-51

DAKS Rel7 Hardware_04.fm

Product Components
General cable cords

Plus connection:

Image 4-37

Nur fr den internen Gebrauch

SUB D-37-M

DIO connector cable K-31100

Element

Description

[1]

SUB D-37-M, solder connection

Table 4-16

4-52

DIO connector cable K-31100


A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

DAKS Rel7 Hardware_04.fm


Product Components
General cable cords

Nur fr den internen Gebrauch

Element

Description

[2]

Cable housing
shielded case
connect cable shield to case

[3]

Cable type:
AMW style 2464/1061 80C 300V
UL no.
E148702
Cross section AWG26

Table 4-16

DIO connector cable K-31100

Pin assignment:
PIN

Function

Color

Description

IN1

white

Input 1

IN3

green

Input 3

IN5

gray

Input 5

IN7

blue

Input 7

IN9

black

Input 9

IN11

white brown

Input 11

IN13

white yellow

Input 13

IN15

white orange

Input 15

IN24V

white red

Internal feeding is possible to connect contacts directly.

10

OUT1a

white violet

Output 1a

11

OUT2a

brown green

Output 2a

12

OUT3a

brown gray

Output 3a

13

OUT4a

brown blue

Output 4a

14

OUT5a

brown black

Output 5a

15

OUT6a

green white

Output 6a

16

OUT7a

green gray

Output 7a

17

OUT8a

green blue

Output 8a

18

REL-NC

green black

Relay break contact

19

REL-NO

20

IN2

Table 4-17

n. c.
brown

Input 2

DIO connector cable - PIN assignment

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-53

DAKS Rel7 Hardware_04.fm

Product Components
General cable cords

Nur fr den internen Gebrauch

PIN

Function

Color

Description

21

IN4

yellow

Input 4

22

IN6

orange

Input 6

23

IN8

red

Input 8

24

IN10

violet

Input 10

25

IN12

white green

Input 12

26

IN14

white gray

Input 14

27

IN16

white blue

Input 16

28

INCOM

white black

Common reference point

29

OUT1b

brown white

Output 1b

30

OUT2b

brown yellow

Output 2b

31

OUT3b

brown orange

Output 3b

32

OUT4b

brown red

Output 4b

33

OUT5b

brown violet

Output 5b

34

OUT6b

green brown

Output 6b

35

OUT7b

green orange

Output 7b

36

OUT8b

green red

Output 8b

37

REL-C

green violet

Relay change-over contact

Table 4-17

4-54

DIO connector cable - PIN assignment

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

4.7.6

DAKS Rel7 Hardware_04.fm


Product Components
General cable cords

RS232 data cable

Bestellnummer:

TNK:K-10225-0500

Funktion:

Cabel to connect the RS232-jack of the CSA-converter (see Section


4.5.1 CSA-Converter) including the DC-Connector for the connection of a a mains power supply (TNK:NT-CSA-0X) for the CSA-Converter.

Technische Daten:

Lnge:

3m

braun
gelb
grn
wei

braun
gelb
grn
wei

Bild 4-38

Anschluss fr
Steckernetzteil
RS232 data cable

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-55

DAKS Rel7 Hardware_04.fm

Product Components
General cable cords

4.7.7

Nur fr den internen Gebrauch

Connector cable OScAR-Pro to CV422-1

Order number:

TNK:K-10225/2-XXXX

Function:

Connection of the Sigmasys fire alarm system to the CV422-1 converter (see Section 4.6.7 Converter from RS422/RS485 to RS232)
to link-up a remote Sigmasys fire alarm system (see Section 6.10
Line extension Sigmasys fire alarm system).

Technical details:

Length

Plug connection:

5.00 m
SUB D-09-F
Heat shrink tube brown
white
brown
black
red
black
Heat shrink tube red

Image 4-39

4-56

Connector cable OScAR-Pro to CV442-1

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

DAKS Rel7 Hardware_04.fm


Product Components
General cable cords

Nur fr den internen Gebrauch

4.7.8

Connector cable Sigmasys to CV422-1

Order number:

TNK:K-10209/2-XXXX

Function:

Connection of the OScAR-Pro server to the the CV422-1 converter


(see Section 4.6.7 Converter from RS422/RS485 to RS232) to
link-up a remote Sigmasys fire alarm system (see Section 6.10
Line extension Sigmasys fire alarm system).

Technical details:

Length

Plug connection:

5.00 m
SUB D-09-F
Heat shrink tube brown
white
brown
red
black
Heat shrink tube red

Image 4-40

Connector cable Sigmasys to CV442-1

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-57

DAKS Rel7 Hardware_04.fm

Product Components
Profibus-DP with ET 200

4.8

Nur fr den internen Gebrauch

Profibus-DP with ET 200

Whenever standalone actuators or sensors need to be connected to one or more central locations, for example input contacts, we recommend the Profibus technology (Process field bus).
Here, a two-wire data shielded and twisted data cable is needed to connect the different Profibus components.
In combination with OScAR-Pro the total length of the Profibus cable, based on a maximum
data rate of 93.75 kbit/s, may not exceed 1200 meters.
Up to 22 standalone line trunk units with an overall maximum of 704 inputs can be connected
to the OScAR-Pro server.
Each line trunk unit can support 32, 64, 96 or 128 inputs.

4.8.1

Input module

Order number:

TNK:ET200L32DI

Technical details:

Number of inputs

32

4.8.2

Terminal block

Order number:

4-58

TNK:TB32L

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

4.8.3

Electric power supply

Order number:

TNK:ML50.100

Technical details:

Input voltage:

Output voltage:

Uin = 115/230 VAC


Uout = 24 V DC

4.8.4

DAKS Rel7 Hardware_04.fm


Product Components
Profibus-DP with ET 200

Profibus adapter

Order number:

TNK:A-PFB-0X

Function:

Adapter to connect the OScAR-Pro server to a Profibus

Image 4-41

Profibus adapter

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-59

DAKS Rel7 Hardware_04.fm

Product Components
Profibus-DP with ET 200

4.8.5

Nur fr den internen Gebrauch

Profibus-Server connector cable

Order number:

TNK:K-10221-XXXX

Technical details:

Standard length:

Max. length:

3m
990 m

Image 4-42

Profibus-Server connector cable

Element

Description

[1]

Bus connector 6ES7 972-0BA50-0XA0

[2]

Connector cable FC 6XV1 830-0EH10

[3]

Bus terminator switch

Table 4-18

Profibus-Server connector cable

Pin assignment
PIN

Function

Color

Shield

RxD/TxD-N

red

RxD/TxD-P

green

Table 4-19

4-60

Profibus-Server connector cable - PIN assignment

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

DAKS Rel7 Hardware_04.fm


Product Components
Profibus-DP with ET 200

Nur fr den internen Gebrauch

4.8.6

Profibus extension cables

Order number:

TNK:K-10222-XXXX

Technical details:

Standard length:

Max. length:

0.6 m
990 m

Image 4-43

Profibus extension cables

Element

Description

[1]

Bus connector 6ES7 972-0BA50-0XA0

[2]

Connector cable FC 6XV1 830-0EH10

[3]

Bus terminator switch

Table 4-20

Profibus extension cables - PIN assignment

Pin assignment
PIN

Function

Color

Shield

RxD/TxD-N

red

RxD/TxD-P

green

Table 4-21

Profibus extension cables - PIN assignment

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

4-61

DAKS Rel7 Hardware_04.fm

Product Components
Profibus-DP with ET 200

4.8.7

Nur fr den internen Gebrauch

Installation of the bus connector

Step 1

Image 4-44

Step 2

Step 3

Installation of the bus connector

Step by step instruction how to install the bus connector:


Step 1

Unfasten the screws of the strain relief lid or flip open the strain relief
lid, and swing the lid to the side. Keep the screws for later use.
Lift the translucent wire guide

Step 2

Slide the Profibus cables into the wire guide path:


Green -> A2, Red -> B2
Now press the translucent wide guide back down

Step 3

Slide the strain relief lid back into its original position or close the lid
with a snap, and fasten the screws.
Put the switch to Off

Table 4-22

4.8.8

Installation of the bus connector

Top-hat rail for Profibus modules

Order number:

TNK:HS00055

Technical details:

Length

0.55 m

4-62

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

DAKS Rel7 Hardware_04.fm


Product Components
Profibus-DP with ET 200

4-63

DAKS Rel7 Hardware_05.fm

Hardware Operations on the OScAR-Pro Server

Nur fr den internen Gebrauch

Hardware Operations on the OScAR-Pro Server

Overview
The first section of this chapter covers the global safety instructions that need to be followed
when putting the OScAR-Pro system into operation. The sections thereafter offer step-be-step
instructions for the different hardware operations on the OScAR-Pro server.
Contents
5.1 General safety instructions
5.3 Rack installation
5.4 Convert to tabletop solution
5.5 Install boards
5.6 Remove boards
5.7 Insert and Remove the CompactFlash card
5.8 Install a bus expansion

5-1

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

5.1

DAKS Rel7 Hardware_05.fm


Hardware Operations on the OScAR-Pro Server
General safety instructions

General safety instructions


Warning
Make sure you read the installation instructions carefully before you connect the system to the electric power source.
Warning
The OScAR-Pro server may only be put into operation by service engineers trained
on OScAR-Pro.
Warning
Make sure you follow the general safety instructions and the ESD protection measures.
Warning
The OScAR-Pro server may not be operated in explosion-risk areas or rooms.

Warning
The OScAR-Pro server you are working on might be connected with more than one
power cord. Please make sure that ALL power cords are removed before you carry
out any servicing work.
Warning
The OScAR-Pro server may only be operated in buildings that have a short circuit or
overload protection. Please always make sure that no fuse protection or interrupter
with over 240 V AC, 16 A (in the US with 120 V AC, 20 A, respectively) is used on
the phase conductors (all current-carrying conductors).
Warning
After disconnecting the DC power cord, make sure that no current-carrying parts of
the DC power plug come into contact with metallic objects.
Warning
Do not perform any operations on the system during a thunderstorm; do not connect
or pull any cords.

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

5-2

DAKS Rel7 Hardware_05.fm

Hardware Operations on the OScAR-Pro Server


General safety instructions

Nur fr den internen Gebrauch

Warning
The jacks marked "Ethernet", "USB Q", "USB B", "RS232", "COM A", "COM B",
"COM C", "COM D", "Digital I/O", "IN 1", "IN 2", "N 3", "IN 4", "OUT 1", "OUT 2", "OUT
3", and "OUT 4" are safety switches with extra low voltage (Safety Extra Low Voltage,
SELV). Please be careful to connect SELV switches only to other SELV switches.
Warning
The jacks marked "E1/T1 A", "E1/T1 B", "E1/T1 C", "E1/T1 D", "S0 A", "S0 B", "S0
C", and "S0 D" are safety switches with TNV-1 circuits.
Warning
If the system runs on AC power supply please be sure to connect the OScAR-Pro
server only to schuko sockets that are fully earthed and in keeping with the legal provisions of the country in which is it used.
Warning
If the system runs on DC power supply please be sure to connect the OScAR-Pro
server only to DC voltage sources that are fully earthed and in keeping with the legal
provisions of the country in which is it used.
Warning
Make sure that the vent holes of the OScAR-Pro server are not covered.

Warning
The OScAR-Pro server can be operated as a tabletop solution or installed in a rack
in a EDP or laboratory environment, and requires a dry, clean, well-ventilated and air
conditioned surrounding. The system is cooled exclusively by way of convection, i.e.
there are no fans in the OScAR-Pro server. For more details on the required ambient
temperature and the humidity please see Chapter 3 , Server Specification.
Warning
Switch fuses are safety-relevant system components and may not be exchanged or
replaced by the user.

5-3

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

DAKS Rel7 Hardware_05.fm


Hardware Operations on the OScAR-Pro Server
Country-specific safety instructions

Warning
The OScAR-Pro server may only be repaired or serviced by the producer and with
the original parts.
No components or parts of the boards may be replaced or exchanged by the user.
Warning
This product may only be disposed in keeping with the pertinent statutory laws and
regulations.
Note: The OScAR-Pro server has no batteries.

5.2

Country-specific safety instructions

5.2.1

Denmark
Vigtigt
Lederen med grn/gul isolation m kuntilsluttes en klemme mrket
(IEC 417, No. 5019) eller (IEC 417, No. 5017).
For tilslutning af de vrige ledere, se medflgende installationsvejledning".

5.2.2

Finland
Variotus
Laite on liitettv suojamaadoituskoskettimilla varustettuun pistorasiaan.

5.2.3

Sweden
Varning
Apparaten skall anslutas till jordat uttag.

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

5-4

DAKS Rel7 Hardware_05.fm

Hardware Operations on the OScAR-Pro Server


Rack installation

5.3

Nur fr den internen Gebrauch

Rack installation
Warning
If additional devices are installed in the rack (e.g. other apparatus, drawers or cables), please make sure that they do not in any way obstruct the venting of the OScAR-Pro server. In particular, the vent holes located the socket and at the top of the
OScAR-Pro server housing may not be obstructed or closed.
Warning
If extractable shelves or drawers are used, make sure their dimension and nominal
load is properly calculated. Also always make sure the dimension of your rack is calculated with pulled-out drawer, to ensure that the rack will not topple if a drawer is
extracted.
Warning
To avoid accidents or injuries during the installation of the OScAR-Pro server in a
rack or while carrying out servicing work, special precautionary measures must be
taken to safeguard the stability of the system. The below guidelines serve to ensure
your safety:
If the OScAR-Pro server is the only installation in the rack, make sure you place
the OScAR-Pro server at the bottom of the rack.
If the OScAR-Pro server is mounted together with other installations in the rack,
make sure the rack is filled from bottom to top with the heaviest installation placed
at the bottom.
If the original rack comes with stabilizer accessories, all stabilizers must be mounted before the OScAR-Pro server is placed in the rack or serviced.
Warning
The OScAR-Pro server may not be installed in a rack if this causes interference or
impairs the functions of the other installations in the same rack (e.g. if it covers the
vent holes of other housings or blocks the vent holes of the rack itself etc.).
Warning
Due to the convection ventilation of the system, please make sure you always leave
an opening of 1 HU both above and below the OScAR-Pro server in the rack.

5-5

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

DAKS Rel7 Hardware_05.fm


Hardware Operations on the OScAR-Pro Server
Rack installation

The OScAR-Pro server can be installed in any standard 19-inch rack with the following technical data:

Width of rack opening 19

Depth of rack opening min. 300 mm

Height dimension

5 HU
Note: Due to the convection ventilation of the system, please make
sure that you always leave an opening of 1 HU both above and below
the OScAR-Pro server in the rack to ensure sufficient airing (see:
Warning).

To install the OScAR-Pro server in a rack you need the rack installation kit (order number:
TNK:GHG-R-01) containing the grab handles with the fastening screws, and a TORX wrench.
Do not remove the feet of the subrack.

Step-by-step instruction how to install the OScAR-Pro server in a rack:


Step

Description

First, remove the grab handles of the tabletop [2] from the subrack [1] by unfastening the fastening screws [3] (use the TORX wrench included in the delivery).

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

5-6

DAKS Rel7 Hardware_05.fm

Hardware Operations on the OScAR-Pro Server


Rack installation

Step

Nur fr den internen Gebrauch

Description

Now fasten the grab handles for the rack case [2] with the fastening screws [3] at
the subrack [1]
3

Now attach OScAR-Pro server (subrack with grab handles) [1] to the rack [4] with
the fastening screws [2] and cage nuts [3].
Note:
The fastening screws[2], cage nuts [3] and Rack [4] are not included in
the delivery.

5-7

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

5.4

DAKS Rel7 Hardware_05.fm


Hardware Operations on the OScAR-Pro Server
Convert to tabletop solution

Convert to tabletop solution

To convert the OScAR-Pro server to a tabletop solution, please use the retrofit kit (order number: TNK:GHG-S-01) containing the grab handles, fastening screws and a TORX wrench.
To convert the OScAR-Pro server to a tabletop solution, please follow the step-by-step instructions of section Section 5.3, "Rack installation" (how to install the OScAR-Pro server in a rack)
in the reverse order.

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

5-8

DAKS Rel7 Hardware_05.fm

Hardware Operations on the OScAR-Pro Server


Install boards

5.5

Nur fr den internen Gebrauch

Install boards
Warning
Make sure ALL power cords (ACP-41 and DCP-41) are disconnected before you carry out any service work on the OScAR-Pro server.
Warning
Make sure you pull all connections to the bus boards you want to remove.

Note
Bus boards can be mounted and removed during the ongoing operation of the system without the risk of causing defects. However, to safeguard the proper operation
of the system after a modification you need to reset the system first.

The boards (power supply boards, bus boards) may not be installed arbitrarily.
For details on the rules governing the configurations that are supported, please refer to the sections:

Configuration of PSUs:

Section 4.2.1.1, "Power supply boards"

Configuration of bus boards:

Section 4.2.1.2, "Bus boards"

If a different board is already inserted in one of the slots in question, please make sure you start
by removing it by following the instructions in Section 5.6, "Remove boards".

5-9

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

DAKS Rel7 Hardware_05.fm


Hardware Operations on the OScAR-Pro Server
Install boards

Step-by-step instruction how to install a board:


Step

Description

Switch the OScAR-Pro server to OFF

Disconnect all power cords (see: Warning)


Cut all connections to the board you want to insert
(see: Warning)

Remove the empty slot cover [2] from the slot:


First remove the fastening screws [1]
Then remove the empty slot cover [2]
4

Plug the PSU [1] or bus board [3] in the vacant slot:
Insert the board into the guide bar [2]

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

5-10

DAKS Rel7 Hardware_05.fm

Hardware Operations on the OScAR-Pro Server


Install boards

Step

Nur fr den internen Gebrauch

Description

Attach the board:


Press safety lever [2] up until it locks
Pull the fastening screws [1] tight
6

If needed, connect external connections to the mounted bus board

Connect all power cables, including to the newly inserted PSU if needed

Finally, switch the OScAR-Pro server back ON

5-11

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

5.6

DAKS Rel7 Hardware_05.fm


Hardware Operations on the OScAR-Pro Server
Remove boards

Remove boards
Warning
Make sure ALL power cords (ACP-41 and DCP-41) are disconnected before you carry out any service work on the OScAR-Pro server.
Warning
Make sure you pull all the connections to the bus boards you want to remove.

Warning
Please be sure to close all subrack slots that are not filled with boards with empty
slot covers.
Step-by-step instruction how to remove a board:
Step

Description

Switch the OScAR-Pro server to OFF

If you want to remove a PSU, make sure all power cords are disconnected
(see Warning)
Cut all connections to the bus board you want to remove
(see: Warning)

Remove the board:


Remove the fastening screws [1]
Press down the safety lever [2] to unlock the board
Now remove the board from the slot

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

5-12

DAKS Rel7 Hardware_05.fm

Hardware Operations on the OScAR-Pro Server


Remove boards

Step

Nur fr den internen Gebrauch

Description

After the PSU or bus board has been removed, be sure to close the vacant slot
with an empty slot cover:
Place the empty slot cover [1] over the vacant slot
5

Attach the empty slot cover:


Pull the fastening screws [1] tight
6

Now connect all power cords again

Finally, switch the OScAR-Pro server back ON

5-13

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

5.7

DAKS Rel7 Hardware_05.fm


Hardware Operations on the OScAR-Pro Server
Insert and Remove the CompactFlash card

Insert and Remove the CompactFlash card

Normally the CompactFlash card does not need to be replaced unless there is a defect on the
card itself.
Step-by-step instruction how to insert and remove a CompactFlash card:
Step

Description

First remove the bus board CPC-41: see Section 5.6, "Remove boards"

CompactFlash card
CPC-41

Now pull the CompactFlash card you want to remove from the CPC-41
3
CPC-41

CompactFlash card

Next insert the new CompactFlash card:


The contacts must be face down
Be careful that the narrow lead on the side of the card points to the left
Be careful that the wide lead on the side of the card points to the right
4

Now install the bus board CPC-41 again: see Section 5.5, "Install boards"

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

5-14

DAKS Rel7 Hardware_05.fm

Hardware Operations on the OScAR-Pro Server


Install a bus expansion

5.8

Nur fr den internen Gebrauch

Install a bus expansion


Warning
Make sure ALL power cords (ACP-41 and DCP-41) are disconnected before you carry out any service work on the OScAR-Pro server.
Warning
Make sure ALL connections to ALL bus boards are pulled (CPC-41, PRA-41, BRA41, SIO-41, DIO-41 and AIO-41).
To install the bus expansion, all bus- and power supply boards must be removed from
the subrack.

The bus expansion adds another 5 slots to the standard bus that consists of 7 slots.
Step-by-step instruction how to install a bus expansion:
Step

Description

Switch the OScAR-Pro server to OFF

Make sure all power cords of the OScAR-Pro server are pulled
(see Warning)

Make sure all connections to the other boards are cut


(see above Warning)

Now remove all bus boards and PSUs from the subrack (see Section 5.6, "Remove boards",also see above Warning)

Attach the 14 guide bars [1] for the bus boards.


Make sure that the grounding springs face to the front side.

5-15

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

Step

DAKS Rel7 Hardware_05.fm


Hardware Operations on the OScAR-Pro Server
Install a bus expansion

Description

Remove the back plate [1]:


Remove the fastening screws [2]
Lift off the back plate
7

You will see the standard bus [1] for 5 slots and the circuit board for the power supply [2].

Disconnect the connecting wires:


Remove the fastening screws [3] from the relevant printed circuit board to disconnect the black [5] and orange [6] power supply lines
Remove the fastening screws [4]
Disconnect the signal transmission line [7]
Put the fastening screws and the wafers aside for later use in Step 11
when you will to re-connect the power supply lines.

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

5-16

DAKS Rel7 Hardware_05.fm

Hardware Operations on the OScAR-Pro Server


Install a bus expansion

Step

Nur fr den internen Gebrauch

Description

Add the bus expansion [1]


9

Attach and loosely connect the 14 fastening screws M2.5x8 for alignment. Do not yet pull tight the fastening screws (see Step 10)!

5-17

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

Step

DAKS Rel7 Hardware_05.fm


Hardware Operations on the OScAR-Pro Server
Install a bus expansion

Description

10

Plug in the bus components:


H.110 Bridge [1]
cPCI-Bridge [2]
To align the bus expansion insert one bus board (any) each in slot
5 and slot 12.
Insert and pull tight the 14 fastening screws M2.5x8.
Now remove the bus boards from slots 5 and 12 again.

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

5-18

DAKS Rel7 Hardware_05.fm

Hardware Operations on the OScAR-Pro Server


Install a bus expansion

Step

Nur fr den internen Gebrauch

Description

11

Attach the connecting wires:


Mount the signal transmission line
Attach the power supply lines black [2][3] and orange [4][5] using the fastening
screws and wafers (see Step 7)
12

The bus expansion with 7 extra slots is now installed

Place the back plate back onto the housing to close the housing

5-19

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

Step

DAKS Rel7 Hardware_05.fm


Hardware Operations on the OScAR-Pro Server
Install a bus expansion

Description

13

To attach the back plate [1] pull tight the fastening screws [2]
14

Remove the fastening screws [2] to lift the empty slot covers [1]
15

Now plug in all bus boards and PSUs in the subrack: see Section 5.5, "Install
boards"

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

5-20

DAKS Rel7 Hardware_05.fm

Hardware Operations on the OScAR-Pro Server


Install a bus expansion

Step

Nur fr den internen Gebrauch

Description

16

Close all vacant slots with empty slot covers [1] (7 slot covers included in the delivery)
17

Link up all external connections to the bus boards

18

Now connect all power cords again

19

Finally, switch the OScAR-Pro server back ON

5-21

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

DAKS Rel7 Hardware_06.fm


Wiring plans

Wiring plans

Overview
This chapter covers the ways in which the boards of the OScAR-Pro server can be connected
to the various external components.
Contents
6.1 CPC-41
6.2 PRA-41
6.3 BRA-41
6.4 SIO-41
6.5 DIO-41
6.6 Line extension of the COM interface (CSA-01-0X)
6.7 Line extension of the Protocol printer for logging (Leiser)
6.8 Line extension of the Host interface (Leiser)
6.9 Line extension via E-Link
6.10 Line extension Sigmasys fire alarm system
6.11 Contact inputs via Profibus-DP with ET 200L
6.11.1 Overall wiring plan
6.11.2 Module and power supply for make contacts
6.11.3 Module wiring for break contacts

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

6-1

DAKS Rel7 Hardware_06.fm

Wiring plans
CPC-41

6.1

Nur fr den internen Gebrauch

CPC-41
tetronik

External
components
1)

1)

2)

Image 6-1

Wiring plan: CPC-41

1) For details on the extension of serial connections for the host and modem see
Section 6.6, "Line extension of the COM interface (CSA-01-0X)"
Section 6.8, "Line extension of the Host interface (Leiser)" and
Section 6.9, "Line extension via E-Link"
2) For details on the extension of serial connections for the logging printer see
Section 6.7, "Line extension of the Protocol printer for logging (Leiser)" and
Section 6.9, "Line extension via E-Link"

6-2

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

DAKS Rel7 Hardware_06.fm


Wiring plans
CPC-41

Nur fr den internen Gebrauch

Element

Description

CPC-41

Control computer

K-CAT6-0300

Standard patch cable

K-USBAB-0300

USB connector cable

Modem

Data Communication Equipment (short DCE)/modem


e.g. telephone modem, E-Link

A-DTE-0X

Adapter to connect the CPC-41 to a DCE device


Pin 1:
Pin 2:
Pin 3:
Pin 4:
Pin 5:
Pin 6:
Pin 7:
Pin 8:
Pin 9:

DCD
RxD
TxD
DTR
GND
DSR
RTS
CTS
RI

PC/Host

Data Terminal Equipment (DTE)

A-DCE-0X

Adapter to connect the CPC-41 to a DTE device


Pin 1:
Pin 2:
Pin 3:
Pin 4:
Pin 5:
Pin 6:
Pin 7:
Pin 8:
Pin 9:

DCD
RxD
TxD
DTR
GND
DSR
RTS
CTS
RI

USB/RS232-0X

Adapter to convert from USB to RS232

LP-OML280

Protocol printer for logging

DUA-41-0X

Adapter to connect a DCF-77 Radio receiver

DCF AD 450

DCF-77 radio receiver

Table 6-1

Wiring plan: CPC-41

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

6-3

DAKS Rel7 Hardware_06.fm

Wiring plans
PRA-41

6.2

Nur fr den internen Gebrauch

PRA-41
tetronik

Image 6-2

External
components

Wiring plan: PRA-41

Warning
For ISDN connections install connection cables with a diameter of at least 0.4 mm
(AWG26 or superior).

6-4

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

DAKS Rel7 Hardware_06.fm


Wiring plans
PRA-41

Element

Description

PRA-41

Primary-Rate Adapter

K-CAT6-0300

Standard patch cable

530267-Z88-A100

Siemens S2M cable 530267-Z88-A100 to network several PBX systems

PBX

Private branch exchange

A-PRN-0X

Adapter to enable direct connectivity of the PRA-41 to a Siemens


PBX (HiPath/OpenScape)
Pin 8:
Rx+
Pin 15: RxPin 1:
Tx+
Pin 9:
TxPin 3:
connected to Pin 10
Pin 7:
connected to Pin 14
Pin 2, 4-6, 11-13: n. c.

A-PRT-0X

Adapter to enable connectivity of the PRA-41 to a Siemens PBX


(HiPath/OpenScape) via a Siemens S2M cable 530267-Z88-A100
Pin 8:
Tx+
Pin 15: TxPin 1:
Rx+
Pin 9:
RxPin 2-7, 10, 11-14: n. c.

RJ45

Pin assignment of the patch cable plug to connect the PRA-41 to a


PBX (any).
Pin 1:
Rx+
Pin 2:
RxPin 4:
Tx+
Pin 5:
TxPin 3, 6-8: n. c

Table 6-2

Wiring plan: PRA-41

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

6-5

DAKS Rel7 Hardware_06.fm

Wiring plans
BRA-41

6.3

Nur fr den internen Gebrauch

BRA-41
tetronik

Image 6-3

External
components

Wiring plan: BRA-41

Warning
For ISDN connections install connection cables with a diameter of at least 0.4 mm
(AWG26 or superior).

6-6

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

DAKS Rel7 Hardware_06.fm


Wiring plans
BRA-41

Element

Description

PRA-41

Primary-Rate Adapter

K-CAT6-0300

Standard patch cable

PBX

Private branch exchange

UAE/8/8/8AP

Universal jack for S0 to connect the BRA-41 to a PBX


Pin 4:
RxPin 5:
Rx+
Pin 3:
Tx+
Pin 6:
TxPin 1,2 7, 8: n. c
[S]
Shield

RJ45

Pin assignment of the patch cable plug to connect the PRA-41 to a


PBX (any).
Pin 4:
RxPin 5:
Rx+
Pin 3:
Tx+
Pin 6:
TxPin 1,2 7, 8: n. c

Table 6-3

Wiring plan: BRA-41

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

6-7

DAKS Rel7 Hardware_06.fm

Wiring plans
SIO-41

6.4

Nur fr den internen Gebrauch

SIO-41
tetronik

External
components

1)

1)

1)

Image 6-4

Wiring plan: SIO-41

1) For details on the extension of serial connections please Section 6.6, "Line
extension of the COM interface (CSA-01-0X)", see Section 6.8, "Line extension
of the Host interface (Leiser)", Section 6.9, "Line extension via E-Link"

6-8

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

DAKS Rel7 Hardware_06.fm


Wiring plans
SIO-41

Nur fr den internen Gebrauch

Element

Comment

SIO-41

Serial Interface

K-CAT6-0300

Standard patch cable

Modem

Data Communication Equipment (DCE)/modem


e.g. telephone modem, E-Link

A-DTE-0X

Adapter to connect the CPC-41 to a DCE device


Pin 1:
Pin 2:
Pin 3:
Pin 4:
Pin 5:

DCD
RxD
TxD
DTR
GND

PC/Host

Data Terminal Equipment (DTE)


e.g. a PC, nurse call system, host computer etc.

A-DCE-0X

Adapter to connect the CPC-41 to a DTE device


Pin 1:
Pin 2:
Pin 3:
Pin 4:
Pin 5:

DCD
RxD
TxD
DTR
GND

Pin 6:
Pin 7:
Pin 8:
Pin 9:

DSR
RTS
CTS
RI

Pin 6:
Pin 7:
Pin 8:
Pin 9:

DSR
RTS
CTS
RI

Profibus

Profibus terminal block as connector element at the OScAR-Pro


server

A-PFB-0X

Adapter to connect the SIO-41 to Profibus-DP


Pin 1:
SHLD
Pin 3:
RxD/TxD-P
Pin 8:
RxD/Txd-N
Pin 5:
DGND
Pin 2, 4, 6, 7, 9: n. c.

UAE/8/8/8AP

Socket for an RS422 interface.


Pin 2:
Tx+/Y
Pin 3:
GND
Pin 4:
Tx-/Z
Pin 5:
Rx+/A
Pin 7:
Rx-/B
Pin 1, 6, 8: n. c.

Table 6-4

Wiring plan: SIO-41

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

6-9

DAKS Rel7 Hardware_06.fm

Wiring plans
DIO-41

6.5

Nur fr den internen Gebrauch

DIO-41
tetronik

External
components

Circuit diagram_ Inputs

Circuit diagram_ Outputs

Circuit diagram_ Relay contacts

Image 6-5

6-10

Wiring plan: DIO-41

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

DAKS Rel7 Hardware_06.fm


Wiring plans
DIO-41

Element

Comment

DIO-41

Digital inputs and outputs

K-31100-xxxx

DIO connector cable

Technical data

37 pin Sub-D jack to connect different inputs and outputs via the DIO
connector cable cord K-31100 (see Section 4.7.5, "Connector cable
for digital inputs and outputs")
16 electrically isolated inputs
Technical data:
Internal feeding possible to connect contacts directly
External power supply:
10.5 .. 60V DC
Uin
Rin
15 k
8 electrically isolated outputs, also isolated from each other
Technical data:
Umax
60 V DC
0.1 A
Imax
RON
11
1 Relay output
Technical data:
Umax
60 V DC
1A
Imax
Pmax
30 W

Table 6-5

Wiring plan: DIO-41

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

6-11

DAKS Rel7 Hardware_06.fm

Wiring plans
Line extension of the COM interface (CSA-01-0X)

6.6

Nur fr den internen Gebrauch

Line extension of the COM interface (CSA-01-0X)

tetronik

External components

RS422
Inhouse
cable network
max. 1000 m

Image 6-6

6-12

Wiring plan: Line extension of the COM interface (CSA-01-0X)

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

DAKS Rel7 Hardware_06.fm


Wiring plans
Line extension of the COM interface (CSA-01-0X)

Element

Comment

SIO-41

Serial Interface card


Ports utilized:
COM A
COM B
COM C
COM D

Modem

Data Communication Equipment (DCE)/Modem


e.g. GSM radio modem

A-DTE-0X

Adapter to connect the OScAR-Pro server to a DCE device


Pin 1:
Pin 2:
Pin 3:
Pin 4:
Pin 5:

DCD
RxD
TxD
DTR
GND

Pin 6:
Pin 7:
Pin 8:
Pin 9:

DSR
RTS
CTS
n. c.

PC/Host

Data Terminal Equipment (DTE)


e.g. a nurse call system

A-DCE-0X

Adapter to connect the OScAR-Pro server to a DTE device


Pin 1:
Pin 2:
Pin 3:
Pin 4:
Pin 5:

K-CAT6-0300

Standard patch cable

UAE/8/8/8AP

Socket for an RS422 interface.

DCD
RxD
TxD
DTR
GND

Pin 6:
Pin 7:
Pin 8:
Pin 9:

DSR
RTS
CTS
n. c.

Pin 2:
Tx+/Y
Pin 3:
GND
Pin 4:
Tx-/Z
Pin 5:
Rx+/A
Pin 7:
Rx-/B
Pin 1, 6, 8: n. c.

CSA-01-0X
Table 6-6

Conversion from RS422 to RS232


Wiring plan: Line extension of the COM interface (CSA-01-0X)

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

6-13

DAKS Rel7 Hardware_06.fm

Wiring plans
Line extension of the Protocol printer for logging (Leiser)

6.7

Nur fr den internen Gebrauch

Line extension of the Protocol printer for logging (Leiser)


tetronik

External
components

Inhouse cable
network

Image 6-7

6-14

Wiring plan: Line extension of the protocol printer for logging (Leiser)

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

DAKS Rel7 Hardware_06.fm


Wiring plans
Line extension of the Protocol printer for logging (Leiser)

Element

Comment

CPC-41

Control computer
Ports utilized:
USB A
USB B

A-USB/RS232-0X

Adapter to convert from USB to RS232

Leiser V2x-90-WP Z104

Transmission kit for OScAR-Pro to Printer

Leiser Vx2-WP Z104

Transmission kit for Printer

UAE/8/8/8AP

Female half connector to extend the RS422 interface

LP-OML280

Protocol printer for logging

Table 6-7

Wiring plan: Line extension of the protocol printer for logging (Leiser)

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

6-15

DAKS Rel7 Hardware_06.fm

Wiring plans
Line extension of the Host interface (Leiser)

6.8

Nur fr den internen Gebrauch

Line extension of the Host interface (Leiser)


tetronik

External
components

Inhouse cable
network

Image 6-8

6-16

Wiring plan: Line extension of the host interface (Leiser)

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

DAKS Rel7 Hardware_06.fm


Wiring plans
Line extension of the Host interface (Leiser)

Element

Comment

SIO-41

Serial Interface card


Ports utilized:
COM A
COM B
COM C
COM D

K-CAT6-0300

Standard patch cable

Leiser V2x-90-WP Z105

Transmission kit for OScAR-Pro to PC/Host

Leiser Vx2-09-WP Z105

Transmission kit for PC/Host

PC/Host

Data Terminal Equipment (DTE)


e.g. a PC, nurse call system, host computer etc.

Table 6-8

Wiring plan: Line extension of the Host interface (Leiser)

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

6-17

DAKS Rel7 Hardware_06.fm

Wiring plans
Line extension via E-Link

6.9

Nur fr den internen Gebrauch

Line extension via E-Link


tetronik
components

External
components

green

red

Inhouse
cable network

red

green

Image 6-9
6-18

Wiring Plan: Line extension E-Link


A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

DAKS Rel7 Hardware_06.fm


Wiring plans
Line extension via E-Link

Nur fr den internen Gebrauch

Element

Comment

CPC-41

Control computer
Ports utilized:
RS232

SIO-41

Serial Interface card


Ports utilized:
COM A
COM B
COM C
COM D

K-CAT6-0300

Standard patch cable

USB/RS232-0X

Adapter to convert from USB to RS232

K-10300-0150

Extension and connector cable D-09-M to D-09-F

UAE/8/8/8AP

Female half connector for the line extension

E-Link 4-T

E-Link modem for line extension

E-Link 9295010200

E-Link special cable cord to connect a the E-Link modem to the


female half connector (UAE/8/8/8AP)

AD-D25MD9F

Adapter between SUB D-09-F and SUB D-25-M

D-09-M/D-25-M

Adapter between SUB D-09-M and SUB D-25-M

A-DTE-0X

Adapter to connect the CPC-41 to a DCE device


Pin 1:
Pin 2:
Pin 3:
Pin 4:
Pin 5:

DCD
RxD
TxD
DTR
GND

Pin 6:
Pin 7:
Pin 8:
Pin 9:

DTE

Data Terminal Equipment (DTE)


e.g. a PC, nurse call system, host computer or other

LP-OML280

Protocol printer for logging

Table 6-9

DSR
RTS
CTS
RI

Wiring Plan: Line extension E-Link

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

6-19

DAKS Rel7 Hardware_06.fm

Wiring plans
Line extension Sigmasys fire alarm system

6.10

Nur fr den internen Gebrauch

Line extension Sigmasys fire alarm system


tetronik
components

External
components

RS422
Inhouse cable
network
max. 1000 m

brown
yellow

white
green

Image 6-10

6-20

Wiring Plan: Line extension Sigmasys fire alarm system

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

DAKS Rel7 Hardware_06.fm


Wiring plans
Line extension Sigmasys fire alarm system

CV

Element

Comment

SIO-41

Serial Interface card


Ports utilized:
COM A
COM B
COM C
COM D

K-CAT6-0300

Standard patch cable

UAE/8/8/8AP

Female half connector for the line extension.

CSA-01-0X

Conversion from RS422 to RS232

K-10401-0300

Adapter to connect the CSA-Converter to the power supply and


to Sigmasys.

NT-CSA-0X

Power supply for the CSA-Converter


input voltage
230 V
output voltage
9V
max. output current
250 mA

Sigmasys

Fire alarm system

Table 6-10

Wiring Plan: Line extension Sigmasys fire alarm system

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

6-21

DAKS Rel7 Hardware_06.fm

Wiring plans
Contact inputs via Profibus-DP with ET 200L

6.11

Nur fr den internen Gebrauch

Contact inputs via Profibus-DP with ET 200L

6.11.1 Overall wiring plan


Profibus adapter A-PFB-0X

Maximum length of bus line in total


1200 m at 93.75kbit/s
(cable type: 6XV1 830-0EH10)
ET 200 L

Switch: OFF

ET 200 L

Switch: OFF

ET 200 L

Switch: ON

Image 6-11

Overall wiring plan

Switch the bus termination resistor switch at the Bus ends to "ON"

6-22

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

DAKS Rel7 Hardware_06.fm


Wiring plans
Contact inputs via Profibus-DP with ET 200L

Nur fr den internen Gebrauch

6.11.2 Module and power supply for make contacts

br 1

bl 1

to max. 3 additional modules


Module addressing
e.g. 01

Power supply
ML50/100

bl
gn/ge

br

Input
power supply
AC 230V

Circuit diagram:

Logic

Image 6-12

Modules and power supply for make contacts

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

6-23

DAKS Rel7 Hardware_06.fm

Wiring plans
Contact inputs via Profibus-DP with ET 200L

Nur fr den internen Gebrauch

6.11.3 Module wiring for break contacts


from the power supply or from
previous module

Module addressing
e.g. 01

Circuit diagram:

Logic

Image 6-13

6-24

Module wiring for break contacts

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Nur fr den internen Gebrauch

DAKS Rel7 Hardware_07.fm


Declaration of Conformity

Declaration of Conformity

Note: The OScAR-Pro Release 7 and the OScAR-Pro V3 are identical in construction.

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

7-1

DAKS Rel7 Hardware_07.fm

Declaration of Conformity

7-2

Nur fr den internen Gebrauch

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

DAKS Rel7 Hardware_SIX.fm

Index

Nur fr den internen Gebrauch

Index

Zahlen
19" construction 4-3
19"Rack 4-3, 5-6

A
AC connector cable 4-49
ACP-41 2-1, 4-4, 4-5, 4-6, 4-10, 4-11, 4-15,
4-49, 5-9, 5-12, 5-15
AD 450 4-29, 6-3
A-DCE 4-41, 6-3, 6-9, 6-13
Add ons 4-29
AD-D25MD9F 6-19
A-DTE 4-43, 6-3, 6-9, 6-13, 6-19
AIO-41 2-2, 4-7, 4-26, 4-27, 5-15
Air cooling 3-1
A-PFB 4-59, 6-9, 6-22
A-PRN 4-44, 6-5
A-PRT 4-45, 6-5
Attributions 1-3

B
Boards 1-2, 2-1, 2-2, 4-4, 4-15, 5-4, 5-9, 512, 5-15, 5-20, 6-1
Installation 5-9
remove 5-12, 5-14
BRA-41 2-2, 4-7, 4-18, 4-19, 4-46, 5-15, 6-6,
6-7
Break contacts (normally closed) 6-24
Bus boards 4-7, 4-8, 5-9, 5-12, 5-15
Bus connector 6ES7 972-0BA50-0XA0 4-60,
4-61
Bus expansion 5-15, 5-17, 5-19
Bus terminator switch 4-60

Convert to tabletop solution 5-8


CPC-41 2-2, 4-7, 4-8, 4-14, 4-15, 4-29, 4-33,
4-35, 5-15, 6-2, 6-3, 6-9, 6-15, 6-19
cPCI 3-1, 5-18
CSA-01-0X 6-13, 6-21
CSA-0X 6-12

D
D-09-F 6-19
D-09-M 6-19
D-09-M/D-25-M 6-19
Data protection 1-2
Data safety 1-2, 1-4
Data security 1-4
Data storage mediums 1-4
DC power cord 4-48
DCF-77 2-2, 4-29, 4-30, 4-31, 4-49, 6-3
DCP-41 2-1, 4-4, 4-5, 4-6, 4-12, 4-13, 4-15,
4-48, 5-9, 5-12, 5-15
Declarations of conformity 3-2
Dialing modem 4-36
DIL switch 4-32
Dimensions 3-1
DIO-41 2-2, 4-24, 4-25, 4-51, 5-15, 6-10, 611
DSP-41 2-2, 4-7, 4-20, 4-21
DTE 4-41, 4-42, 6-3, 6-9, 6-13, 6-17, 6-19
DUA-41 2-2, 4-29, 4-30, 4-49, 6-3

E
E1 2-1, 2-2, 4-16, 4-17, 4-53, 5-3
E-Link 4-35, 6-3, 6-9, 6-18, 6-19
E-Link 4-T 6-19
E-Link 9295010200 6-19
ESPA 4.4.4 2-3
ET 200L 6-22

GSM 4-36

Certifications 3-2
CompactFlash card 4-28
Connector cable FC 6XV1 830-0EH10 4-60,
4-61
Contact inputs via Profibus-DP 6-22

H
H.110 Bridge 5-18
Hardware operations 5-1
HiPath 2-1, 4-44, 4-45, 6-5
HiPath4000 2-1

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Z-1

DAKS Rel7 Hardware_SIX.fm

Index

Nur fr den internen Gebrauch

Host interface 6-16, 6-17


Humidity 3-1, 5-3

I
IEC inlet connector for non-heating apparatus
4-11
IEC jack 4-11
Inlet connector for non-heating apparatus 411
Inputs 6-10

K
K-10300-0150 6-19
K-10401-0300 6-21
K-31000-xxxx 6-11
K-31100 4-25, 4-52, 6-11
K-CAT6-0300 6-3, 6-5, 6-7, 6-9, 6-13, 6-17,
6-19, 6-21
K-USBAB-0300 6-3

L
LAN 2-2, 4-15, 4-50
LED 4-15, 4-17, 4-19, 4-21, 4-23, 4-27
Leiser V2x-90-WP Z104 6-15
Leiser V2x-90-WP Z105 6-17
Leiser Vx2-09-WP Z105 6-17
Leiser Vx2-WP Z104 6-15
Light-emitting diode 4-8, 4-21, 4-23, 4-27
Line 4-35
Line extension 1-2, 4-34, 4-35, 4-37, 4-38, 439, 4-40, 4-46, 6-14, 6-15, 6-16, 6-17, 6-18,
6-19, 6-20, 6-21
LP-OML280 6-3, 6-15, 6-19

M
Make contacts (normally open) 6-23
Modem 4-35, 4-36, 4-43, 6-3, 6-9, 6-13
MTBF 3-1

N
Notations 1-2, 1-3
NT-CSA-0X 6-21

O
OKI Microline 280 4-32

Z-2

OpenScape 4-44, 4-45, 6-5


OpenScape 4000 2-1
Operating temperature 3-1
Outputs 6-10
Overall wiring plan 6-22

P
Patch field 4-46
Power cords 5-2, 5-9, 5-10, 5-11, 5-12, 5-13,
5-15, 5-21
Power supply 2-1, 3-1, 4-4, 4-8, 4-9, 4-10, 411, 4-12, 4-13, 4-15, 4-29, 4-30, 4-48, 4-59,
5-16
PRA-41 2-2, 4-7, 4-16, 4-17, 4-44, 4-45, 6-4,
6-5, 6-7
Printer 4-32, 6-3, 6-14, 6-15
Product Components 4-1
Profibus 4-50, 4-59
Profibus adapter 4-59
Profibus DP 4-58, 6-9, 6-22
Profibus extension cables 4-61
Profibus modules 4-62
Profibus-DP 2-3
Profibus-Server connector cable 4-60
Protocol printer for logging 4-32, 6-14, 6-15

R
Rack installation 5-5, 5-6
Relay output 2-2, 4-25, 6-11
RJ45 4-15, 4-17, 4-19, 4-23, 4-41, 4-42, 443, 4-44, 4-45, 4-46, 4-47, 6-5, 6-7
RS232 2-2, 2-3, 4-15, 4-23, 4-33, 4-35, 4-50,
5-3, 6-3, 6-15, 6-19
RS485 2-3, 4-23

S
S0 2-1, 2-2, 4-18, 4-19, 4-50, 5-3, 6-7
S2M 2-1, 2-2, 4-45, 4-50, 6-5
Safety instructions 1-2, 5-1, 5-2
Sigmasys 6-20, 6-21
SIO-41 2-3, 4-7, 4-22, 4-23, 4-35, 4-37, 4-38,
5-15, 6-8, 6-9, 6-13, 6-17, 6-19, 6-21
Slot 2-1, 4-3, 4-4, 4-7, 5-9, 5-10, 5-12, 5-13,
5-15, 5-16, 5-18, 5-21
Slots 3-1, 4-3, 5-19
07/2010
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

DAKS Rel7 Hardware_SIX.fm

Index

Nur fr den internen Gebrauch

SMS 4-36
Status indicator 4-9, 4-17, 4-19, 4-21, 4-23,
4-29, 4-30, 4-31
SUB D-09-F 4-41, 4-42, 6-19
SUB D-09-M 4-43, 6-19
SUB D-15-M 4-44, 4-45
SUB D-25-M 6-19
SUB D-37-M 4-52
Subrack 4-3, 5-6, 5-7, 5-12, 5-15, 5-20
Symbols 1-2, 1-3

T
T1 2-1, 2-2, 4-16, 4-17, 5-3
Target audience 1-1
The Ethernet 2-2, 4-15, 5-3
The Patch cable 4-50, 4-56, 6-3, 6-5, 6-7, 69, 6-13, 6-17, 6-19, 6-21
TNK:ACP-41-0X 4-10
TNK:AD450 4-30
TNK:A-DCE-01 4-41
TNK:A-DCE-02 4-42
TNK:A-DTE-0X 4-43
TNK:AIO-41-0X 4-26
TNK:AMOD56k 4-36
TNK:A-PFB-0X 4-59
TNK:A-PRN-0X 4-44
TNK:A-PRT-0X 4-45
TNK:A-USB/RS232-01 4-33
TNK:BRA-41-0X 4-18
TNK:CF-1G-01 4-28
TNK:CPC-41-0X 4-14
TNK:CSA-01 4-34
TNK:DCP-41-0X 4-12
TNK:devolo MicroLink 56k 4-36
TNK:DIO-41-0X 4-24
TNK:DSP-41-0X 4-20
TNK:DUA-41-0x 4-29
TNK:E-LINK4-T 4-35
TNK:ET200L32DI 4-58
TNK:FM-TC35I 4-36
TNK:GHG-R-01 5-6
TNK:GHG-S-01 5-8
TNK:HS00055 4-62
TNK:K-10221-XXXX 4-60

TNK:K-10222-XXXX 4-61
TNK:K-10225-0500 4-55
TNK:K-31100-xxxx 4-51
TNK:K-51001-0600 4-48
TNK:K-AC-D-0180 4-49
TNK:K-CAT6-0300 4-50, 4-56, 4-57
TNK:K-USBAB-0300 4-49
TNK:LP-OML280 4-32
TNK:ML50.100 4-59
TNK:NT-CSA-0X 4-55
TNK:PRA-41-0X 4-16
TNK:SIO-41-0X 4-22
TNK:TB32L 4-58
TNK:UAE/8/8/8AP 4-46, 4-47
TNK:V2X-90-WPZ104 4-39
TNK:V2X-90-WPZ105 4-37
TNK:VX2-09-WPZ105 4-38
TNK:VX2-WPZ104 4-40
Transmission kit for DAKS to PC/Host 4-37,
6-17
Transmission kit for DAKS to Printer 4-39, 615
Transmission kit for PC/Host 4-38, 6-17
Transmission kit for Printer 4-40, 6-15

U
UAE/8/8/8aP 6-7, 6-9, 6-13, 6-15, 6-19, 6-21
USB 2-2, 4-15, 4-29, 4-32, 4-33, 4-49, 5-3, 63, 6-15
USB/RS232-0X 6-3, 6-19

V
VCON 4-8
VoIP 2-1, 2-2

W
Warning 1-3, 4-1, 5-2, 5-3, 5-4, 5-5, 5-6, 5-9,
5-12, 5-15
Weight 3-1
Wiring plans 6-1

A31003-S1730-S103-1-7620
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

Z-3

DAKS Rel7 Hardware_SIX.fm

Index

Z-4

Nur fr den internen Gebrauch

07/2010
OScAR-Pro V3 R2 Classic Applications, Administrator Manual

You might also like