0% found this document useful (0 votes)
73 views6 pages

Na Prasad Report Excel

This document provides load combinations and load calculations for a building. It specifies dead loads, superimposed dead loads, and live loads for floor slabs, walls, and roof slabs. It also provides seismic load calculations based on IS 1893 for the building. Load combinations are listed that include dead loads, live loads, and seismic loads in different combinations. Storey weights and lateral seismic forces distributed to each storey are also included.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
73 views6 pages

Na Prasad Report Excel

This document provides load combinations and load calculations for a building. It specifies dead loads, superimposed dead loads, and live loads for floor slabs, walls, and roof slabs. It also provides seismic load calculations based on IS 1893 for the building. Load combinations are listed that include dead loads, live loads, and seismic loads in different combinations. Storey weights and lateral seismic forces distributed to each storey are also included.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 6

3.

LOADING AND LOAD COMBINATIONS


3.1 DEAD LOAD AND SUPER IMPOSED DEAD LOAD
3.1.1 Dead Load is the self weight of the slab
Self weight of 110 mm thick slab

0.11 x

25 =

2.75 kN/m2

1 kN/m2

3.1.1 SIDL
a) From 1st floor level to 3rd floor level
Floor Finishes
b) Roof Level
Floor Finishes

1 kN/m2

3.2 LIVE LOADS


a) From 2st floor level to 3rd floor level
Live Load in rooms
Live Load in Balconies and Corridors
b) Roof level

2
3

Live Load (acessible)

1.5 kN/m2

Live Load (Non-accessible)

1 kN/m2

Live Load

3 kN/m2

c)Stair

Determining Seismic Load based on IS 1893


Seismic zoning factor, Z
Importance factor, I
Structural Performance Factor, K
Dimension of the building along X, Dx
Dimension of the building along Y, Dy
Time preiod of the building along X, Tx
Time preiod of the building along Y, Ty
Soil Type
Basic Seismic coefficient along X, C
Basic Seismic coefficient along Y, C
Design Horizontal Seismic Coefficient, Cd
Seismic Weight of the Building (DL+0.25LL)
Base Shear

=
0.36
=
1
=
1
=
9.98 m
=
12.42 m
=
0.389 sec
=
0.389 sec
= II
=
0.08
=
0.08
=
0.08
=
1123.4
=
326.34

Determining Seismic Load based on IS 1893


Seismic zoning factor, Z
Importance factor, I
Height of the Building
Time preiod of the building along X, Tx
Time preiod of the building along Y, Ty
Soil Type
Seismic zone factor
Average response acceleration coefficient
Response reduction factor
Design Horizontal Seismic Coefficient, Ah
Seismic Weight of the Building (DL+0.25LL)
Base Shear

=
=
=
=
=
=
=
=
=
=
=
=

0.36
1
9m
0.389 sec
0.389 sec
II
0.36
2.5
5
0.09
2491.9 kN
224.271 KN

Distribution of Lateral Forces along different storey


Storey
Storey Level Height (Hi)
Stair Cover
9
2nd floor
6
1st floor
3
Total

Wi
Wi*Hi
Fi=V*(WiHi/WiHi)
135.23 1730.89
34.9176937057
1554.59 9949.38
200.7114278791
1405.18 4496.59
90.7108784152
3095 16176.86

S.NO
1)
2)
3)
4)
5)
6)
7)
8)
9)
10 )
11 )
12 )
13 )

Load Comb
Comb 1
Comb 2
Comb 3
Comb 4
Comb 5
Comb 6
Comb 7
Comb 8
Comb 9
Comb 10
Comb 11
Comb 12
S. WT

Description
1.0 (Dead Load) + 1.3 (Live Load) + 1.25 (Eqx)
1.0 (Dead Load) + 1.3 (Live Load) - 1.25 (Eqx)
1.0 (Dead Load) + 1.3 (Live Load) + 1.25 (Eqy)
1.0 (Dead Load) + 1.3 (Live Load) - 1.25 (Eqy)
0.9 (Dead Load) + 1.25 (Eqx)
0.9 (Dead Load) - 1.25 (Eqx)
0.9 (Dead Load) + 1.25 (Eqy)
0.9 (Dead Load) - 1.25 (Eqy)
1.0 (Dead Load) + 1.3 (SL) + 1.25 (Eqx)
1.0 (Dead Load) + 1.3 (SL) - 1.25 (Eqx)
1.0 (Dead Load) + 1.3 (SL) + 1.25 (Eqy)
1.0 (Dead Load) + 1.3 (SL) - 1.25 (Eqy)
1.0 ( Dead Load ) + 0.25 (Live Load)

a) At Ground Floor level


230 mm thick brick wall load
115mm thick brick wall load
Live Load in rooms
Live Load in Balconies & Corridors

=
=

b) At 1st to 2nd floor level


Dead load
=
Self weight of the Slab + SIDL
115 mm thick brick wall load
=
=
Live Load in rooms
Live Load in Balconies & Corridors
c) Roof level
Dead load
=
Self weight of the Slab + SIDL
Live Load (accessible)
Live Load (Non-accessible)

0.23 x
0.115 x

3x
3x

20 =
20 =
=
=

13.8
6.9
2
3

=
0.115 x

2.75 +
3x

1=
20 =
=
=

3.75
6.9
2
3

=
=
=

2.75 +
1.5 x
1x

1=
0.5 =
0.5 =

3.75
0.75
0.5

kN/m
kN/m
kN/m2
kN/m2

kN/m2
kN/m
kN/m2
kN/m2

kN/m2
kN/m2
kN/m2