UL - LM 79 08 - Photometric - HB 0615 120

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

Optical Report For Solid-State

Lighting Products

This laboratory is accredited in accordance with the recognized International Standard


ISO/IEC 17025:2005. This accreditation demonstrates technical competence for a defined
scope and the operation of a laboratory quality management system (refer to the joint ISOILAC-IAF Communiqu dated January 2009).

Standard Used :

Date of Test :
Date of Issue :
Report Number :

IESNA LM-79-08, Approved Method :


Electrical and Photometric Measurements
of Solid-State Lighting Products.
December 23, 2015 to December 25, 2015
December 25, 2015
GO1512220401

www.GO-SAFETY.com.tw

www.GO-SAFETY.com.tw

www.GO-SAFETY.com.tw

TEST REPORT
The Optical Report For Solid-State Lighting Products
Report Number.................................... : GO1512220401
Date of test ............................................ : December 23, 2015 to December 25, 2015
Date of issue .......................................... : December 25, 2015
Tested by
(printed name and signature)................. : Johnson Wang
Reported by
(printed name and signature)................. : Johnson Wang
Approved by
(printed name and signature) ................ : David Yuan

Johnson Wang
Johnson Wang
David Yuan

Testing Laboratory ............................. : Great One Global Certification Co., Ltd.


Address .................................................. :

9F-2, No. 120, Qiaohe Rd., Zhonghe Dist., New Taipei


City 235, Taiwan (R.O.C.)

Applicants name................................. : PT Solarens Ledindo.


Address .................................................. :

Metro Indah Mall J 33, Jl. Soekarno-Hatta 590, Bandung


40286, West Java, Indonesia.

IESNA LM-79-08, Approved Method: Electrical and


Standard Used ..................................... : Photometric Measurements of Solid-State Lighting
Products
Test item description ........................... :
Product Name ........................................ : LED High Bay Light
Model/Type reference ........................... : HB-0615-120
Ratings .................................................. : 120 Vac to 277 Vac, 50/60 Hz, 1.5 A, 120 W
Reported By :

Reviewed By :

Johnson Wang
Johnson Wang
Project Engineer

David Yuan
Manager

1. The test results of this report relate only to the tested sample identified in this report.
2. This report shall not be reproduced, in full or in portion, except for having written approval from
Great One Global Certification Co., Ltd.
3. The data in report cannot be used for advertisement, publication and promotion.
GO1512220401

www.GO-SAFETY.com.tw

Page : 1/13

SUMMARY OF PHOTOMETRY TEST:


1. Test Method :
The sample was tested according to the LM-79-2008.
A Type C High Speed Mirror Type Goniophotometer was used to measure the intensity (candelas)
at each angle of distribution for each sample..
A Spectroradiometer and a Integrating Sphere were used to measure correlated color temperature,
chromaticity coordinates, and the color rendering index for each sample. Chromaticity
coordinates, correlated color temperature and color rendering index were calculated from the
spectral radiant flux measurements taken at 5 nm intervals over the range of 380 to 780 nm.The
calibration of the sphere photometer-spectroradiometer system is traceable to the National Institute
of Standards and Technology.
The ambient temperature shall be maintained at 25C 1C. Each sample was operated at input
rated voltage in its designated orientation.
Electrical measurements including voltage, current, and power were measured using the
Yokogawa Power Analyzer.
Deviation from Standard operating procedures None.

2.Test item particulars :


Tested lamp ....................................................: continuous wave lamps

pulsed lamps

Tested lamp system ......................................... : LED


Lamp cap ........................................................: N/A
Bulb ................................................................: N/A
Rated of the lamp ............................................. : 120 Vac to 277 Vac, 50/60 Hz, 1.5 A, 120 W
Temperature by measurement ......................... : 25.5 C
Humidity by measurement .............................. : 56.0 % to 60.0 %

3.Description of EUT Setup :


Operating Orientation ....................................: The light source is considered as horizontal
Light Source ...................................................: LED
Stabilization time ...........................................: 1 Hour

GO1512220401

www.GO-SAFETY.com.tw

Page : 2/13

4. Photograph of EUT of Sample :


Angle Definition :

GO1512220401

www.GO-SAFETY.com.tw

Page : 3/13

RESULTS
(1) Input Voltage / Frequency : 120.00 Vac / 60 Hz
(2) Input Watt : 121.00 W
(3) Input Current : 1.015 A
(4) Total Luminous Flux Output : 13342.78 lm
(5) Luminaire Efficacy : 110.27 lm/W
(6) Central Intensity : 15227.590 cd
(7) Maximum Intensity : 15240.150 cd
(8) PF : 0.994
(9) Beam Angle : (C0-C180) : 55.2, (C90-C270) : 54.4
(10) Correlated Color Temperature (CCT) : 4825 K
(11) Duv : -0.00063
(12) Color Rendering Index (CRI) : 85.1

Measurement Results : See Appendix A for details.

GO1512220401

www.GO-SAFETY.com.tw

Page : 4/13

Equipment List
Equipment
ID

Equipment Type

Cal. Date

Due Date

L201

Integrating Sphere

N/A

N/A

L202

Spetroradiometer

N/A

N/A

L203

AC Power Source

N/A

N/A

L222

Power Meter

2015/10/09

2016/10/08

L217

Goniophotometer
Photo Detector

N/A

N/A

L218

Goniophotometer System

N/A

N/A

L219

AC Power Source

N/A

N/A

L220

Power Meter

2015/08/26

2016/08/25

L221

Luminous Intensity Lamp

2015/11/12

2016/11/11

L242

DC Standard Light

2015/10/13

2016/10/12

Range Used

V : Auto
(0~300Vac)
A : Auto
(0~20A)

AC 0~150VAC4.2A
AC0~300VAC2.1A
V : Auto
(0~300Vac)
A : Auto
(0~20A)

~ End of Report ~

GO1512220401

www.GO-SAFETY.com.tw

Page : 5/13

Appendix A
Great One Global Certification Co., Ltd.
===========================================================================
Product: HB-0615-120
Manufacturer: PT Solarens Ledindo.
Sample No.: 15122204-1
Date: 12-25-2015
Tested By: Johnson Wang
Reviewed By: David Yuan

Test Condition
Temperature: 25.5C
Spectrum Range: 350-800 nm

RH: 60.0%
Scan Step: 5 nm

Spectroradiometric Parameters
1.0
0.8
0.6
0.4
0.2
0

350

425

500

575

650

725

800

Spectral Distribution

SDCM:ANSI_LED_5000K
x0=0.3447 y0=0.3553

Chromaticity Coordinates: x=0.3500 y=0.3543 u'=0.2137 v'=0.4867


Correlated Color Temperature: 4825 K

Dominant Wavelength: 574.0 nm(E)

Chromaticity Difference: -0.00063Duv

Purity: 0.1133

Color Ratio: Kr=34.5% Kg=54.8% Kb=10.7%

Peak Wavelength: 450.0 nm

Bandwidth: 25.4nm

Color Tolerance: 0.0 SDCM

Rendering Index: Ra=85.1

Radiant Flux: 42.067 W

R1=84

R2=89

R3=91

R4=85

R5=84

R6=83

R7=90

R9=29

R10=72

R11=84

R12=61

R13=86

R14=95

R15=81

GO1512220401

www.GO-SAFETY.com.tw

R8=75

Page : 6/13

Appendix A
PT Solarens Ledindo. HB-0615-120
Light Distribution Curve [Unit: cd]

180

-90

90
3048.03
6096.06
9144.09
12192.12
15240.15
0

15240.15
12192.12
9144.09
6096.06
3048.03
0.00

-180

-135

-90

-45

45

90

135

180

C0/C180:
C90/C270:
Equipment: GMS1980
Temperature(C): 25.5

GO1512220401

Date: 2015/12/23
Humidity(%): 60.0%

www.GO-SAFETY.com.tw

Operator: Johnson Wang


Distance(m): 9.00

Page : 7/13

Appendix A
PT Solarens Ledindo. HB-0615-120
Lux distance Curve

1.0m

15227.59lx

2.0m
3.0m
4.0m
5.0m
6.0m
7.0m
8.0m
9.0m
10.0m
11.0m
12.0m

3806.90lx
1691.96lx
951.72lx
609.10lx
422.99lx
310.77lx
237.93lx
188.00lx
152.28lx
125.85lx
105.75lx

Equipment: GMS1980
Temperature(C): 25.5

GO1512220401

Date: 2015/12/23
Humidity(%): 60.0%

www.GO-SAFETY.com.tw

Operator: Johnson Wang


Distance(m): 9.00

Page : 8/13

Appendix A
PT Solarens Ledindo HB-0615-120
ISO-Intensity(V-H)8

90

Imax:15240.15cd

[Unit:cd]

75
60
45
30
15
0
-15
-30
-45
-60
-75
-90
-90

-75

-60

-45

-30

-15

15

30

45

60

75

90

(10%Imax) 1521.06
(20%Imax) 3042.12
(30%Imax) 4563.18
(40%Imax) 6084.23
(50%Imax) 7605.29
(60%Imax) 9126.35
(70%Imax) 10647.4
(80%Imax) 12168.5
(90%Imax) 13689.5
Equipment: GMS1980
Temperature(C): 25.5

GO1512220401

Date: 2015/12/23
Humidity(%): 60.0%

www.GO-SAFETY.com.tw

Operator: Johnson Wang


Distance(m): 9.00

Page : 9/13

Appendix A
PT Solarens Ledindo. HB-0615-120
ISO illuminance diagram
0.8d/h

Imax:15240.15cd

[Unit:lx] H=9.0m

0.7

0.5

0.3

0.2

0.0

0.2

0.3

0.5

0.7

0.8d/h

0.8d/h

0.7

0.5

0.3

0.2

0.0

0.2

0.3

0.5

0.7

0.8d/h

(10%Emax) 18.79803
(20%Emax) 37.59592
(30%Emax) 56.39395
(40%Emax) 75.19197
(50%Emax) 93.99
(60%Emax) 112.7879
(70%Emax) 131.5864
(80%Emax) 150.3839
(90%Emax) 169.1815

Equipment: GMS1980
Temperature(C): 25.5

GO1512220401

Date: 2015/12/23
Humidity(%): 60.0%

www.GO-SAFETY.com.tw

Operator: Johnson Wang


Distance(m): 9.00

Page : 10/13

Appendix A
PT Solarens Ledindo. HB-0615-120
Intensity data(cd)
C/()
0.0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
100.0
110.0
120.0
130.0
140.0
150.0
160.0
170.0
180.0
190.0
200.0
210.0
220.0
230.0
240.0
250.0
260.0
270.0
280.0
290.0
300.0
310.0
320.0
330.0
340.0
350.0
360.0

0.0
15227.59
15230.83
15230.83
15224.76
15229.62
15223.14
15210.99
15230.02
15226.79
15210.58
15221.52
15226.38
15203.70
15239.34
15226.38
15239.34
15229.62
15215.85
15227.59
15230.83
15230.83
15224.76
15229.62
15223.14
15210.99
15230.02
15226.79
15210.58
15238.53
15224.76
15206.94
15231.24
15240.15
15231.24
15225.57
15240.15
15227.59

Equipment: GMS1980
Temperature(C): 25.5

GO1512220401

5.0
14963.13
14975.68
14967.18
14955.27
14952.03
14953.25
14926.52
14946.12
14937.21
14924.25
14937.21
14946.12
14926.52
14953.25
14952.03
14955.27
14967.18
14975.68
14963.13
14975.68
14967.18
14955.27
14952.03
14953.25
14926.52
14946.12
14937.21
14924.25
14937.21
14946.12
14926.52
14953.25
14952.03
14955.27
14967.18
14975.68
14963.13

10.0
14235.75
14243.85
14223.60
14199.30
14164.47
14153.54
14101.13
14095.05
14065.65
14046.61
14065.65
14095.05
14101.13
14153.54
14164.47
14199.30
14223.60
14243.85
14235.75
14243.85
14223.60
14199.30
14164.47
14153.54
14101.13
14095.05
14065.65
14046.61
14065.65
14095.05
14101.13
14153.54
14164.47
14199.30
14223.60
14243.85
14235.75

15.0
13016.70
13030.88
12998.48
12951.90
12901.27
12830.40
12769.65
12735.23
12719.02
12696.75
12719.02
12735.23
12769.65
12830.40
12901.27
12951.90
12998.48
13030.88
13016.70
13030.88
12998.48
12951.90
12901.27
12830.40
12769.65
12735.23
12719.02
12696.75
12719.02
12735.23
12769.65
12830.40
12901.27
12951.90
12998.48
13030.88
13016.70

20.0
11384.55
11384.55
11354.17
11311.65
11256.98
11194.20
11123.33
11078.77
11036.25
11024.10
11036.25
11078.77
11123.33
11194.20
11256.98
11311.65
11354.17
11384.55
11384.55
11384.55
11354.17
11311.65
11256.98
11194.20
11123.33
11078.77
11036.25
11024.10
11036.25
11078.77
11123.33
11194.20
11256.98
11311.65
11354.17
11384.55
11384.55

25.0
9088.20
9080.10
9043.65
8991.00
8940.38
8893.80
8849.25
8829.00
8798.63
8804.70
8798.63
8829.00
8849.25
8893.80
8940.38
8991.00
9043.65
9080.10
9088.20
9080.10
9043.65
8991.00
8940.38
8893.80
8849.25
8829.00
8798.63
8804.70
8798.63
8829.00
8849.25
8893.80
8940.38
8991.00
9043.65
9080.10
9088.20

Date: 2015/12/23
Humidity(%): 60.0%

www.GO-SAFETY.com.tw

30.0
6273.45
6267.38
6232.95
6182.33
6145.88
6115.50
6085.13
6079.05
6075.00
6079.05
6075.00
6079.05
6085.13
6115.50
6145.88
6182.33
6232.95
6267.38
6273.45
6267.38
6232.95
6182.33
6145.88
6115.50
6085.13
6079.05
6075.00
6079.05
6075.00
6079.05
6085.13
6115.50
6145.88
6182.33
6232.95
6267.38
6273.45

35.0
3836.16
3827.49
3808.86
3781.89
3757.83
3721.14
3711.02
3713.69
3725.19
3742.61
3725.19
3713.69
3711.02
3721.14
3757.83
3781.89
3808.86
3827.49
3836.16
3827.49
3808.86
3781.89
3757.83
3721.14
3711.02
3713.69
3725.19
3742.61
3725.19
3713.69
3711.02
3721.14
3757.83
3781.89
3808.86
3827.49
3836.16

40.0
2200.37
2194.70
2179.95
2154.03
2131.52
2119.37
2118.56
2127.71
2140.43
2144.48
2140.43
2127.71
2118.56
2119.37
2131.52
2154.03
2179.95
2194.70
2200.37
2194.70
2179.95
2154.03
2131.52
2119.37
2118.56
2127.71
2140.43
2144.48
2140.43
2127.71
2118.56
2119.37
2131.52
2154.03
2179.95
2194.70
2200.37

Operator: Johnson Wang


Distance(m): 9.00

Page : 11/13

Appendix A
PT Solarens Ledindo. HB-0615-120
Intensity data(cd)
C/()
0.0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
100.0
110.0
120.0
130.0
140.0
150.0
160.0
170.0
180.0
190.0
200.0
210.0
220.0
230.0
240.0
250.0
260.0
270.0
280.0
290.0
300.0
310.0
320.0
330.0
340.0
350.0
360.0

45.0
1253.88
1244.97
1227.96
1211.60
1202.28
1199.61
1204.88
1210.38
1212.41
1210.95
1212.41
1210.38
1204.88
1199.61
1202.28
1211.60
1227.96
1244.97
1253.88
1244.97
1227.96
1211.60
1202.28
1199.61
1204.88
1210.38
1212.41
1210.95
1212.41
1210.38
1204.88
1199.61
1202.28
1211.60
1227.96
1244.97
1253.88

Equipment: GMS1980
Temperature(C): 25.5

GO1512220401

50.0
744.80
740.99
732.89
724.38
717.66
715.23
717.90
721.14
722.76
724.14
722.76
721.14
717.90
715.23
717.66
724.38
732.89
740.99
744.80
740.99
732.89
724.38
717.66
715.23
717.90
721.14
722.76
724.14
722.76
721.14
717.90
715.23
717.66
724.38
732.89
740.99
744.80

55.0
478.71
477.90
476.12
473.12
466.64
463.16
462.75
465.18
468.99
472.64
468.99
465.18
462.75
463.16
466.64
473.12
476.12
477.90
478.71
477.90
476.12
473.12
466.64
463.16
462.75
465.18
468.99
472.64
468.99
465.18
462.75
463.16
466.64
473.12
476.12
477.90
478.71

60.0
328.21
328.62
329.18
328.94
324.73
320.76
319.71
320.68
324.41
326.75
324.41
320.68
319.71
320.76
324.73
328.94
329.18
328.62
328.21
328.62
329.18
328.94
324.73
320.76
319.71
320.68
324.41
326.75
324.41
320.68
319.71
320.76
324.73
328.94
329.18
328.62
328.21

65.0
233.60
233.77
234.50
234.82
232.15
229.88
229.07
229.55
231.42
233.04
231.42
229.55
229.07
229.88
232.15
234.82
234.50
233.77
233.60
233.77
234.50
234.82
232.15
229.88
229.07
229.55
231.42
233.04
231.42
229.55
229.07
229.88
232.15
234.82
234.50
233.77
233.60

70.0
167.43
167.59
167.99
168.32
167.10
165.89
165.32
165.56
166.78
167.43
166.78
165.56
165.32
165.89
167.10
168.32
167.99
167.59
167.43
167.59
167.99
168.32
167.10
165.89
165.32
165.56
166.78
167.43
166.78
165.56
165.32
165.89
167.10
168.32
167.99
167.59
167.43

Date: 2015/12/23
Humidity(%): 60.0%

www.GO-SAFETY.com.tw

75.0
120.61
120.61
121.42
121.58
121.01
119.96
119.56
119.96
121.01
121.34
121.01
119.96
119.56
119.96
121.01
121.58
121.42
120.61
120.61
120.61
121.42
121.58
121.01
119.96
119.56
119.96
121.01
121.34
121.01
119.96
119.56
119.96
121.01
121.58
121.42
120.61
120.61

80.0
84.40
84.81
85.86
85.70
85.45
84.40
83.84
84.24
85.45
85.45
85.45
84.24
83.84
84.40
85.45
85.70
85.86
84.81
84.40
84.81
85.86
85.70
85.45
84.40
83.84
84.24
85.45
85.45
85.45
84.24
83.84
84.40
85.45
85.70
85.86
84.81
84.40

85.0
54.03
54.76
55.81
55.65
55.32
54.27
53.87
54.35
55.49
55.24
55.49
54.35
53.87
54.27
55.32
55.65
55.81
54.76
54.03
54.76
55.81
55.65
55.32
54.27
53.87
54.35
55.49
55.24
55.49
54.35
53.87
54.27
55.32
55.65
55.81
54.76
54.03

Operator: Johnson Wang


Distance(m): 9.00

Page : 12/13

Appendix A
PT Solarens Ledindo. HB-0615-120
Intensity data(cd)
C/()
0.0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
100.0
110.0
120.0
130.0
140.0
150.0
160.0
170.0
180.0
190.0
200.0
210.0
220.0
230.0
240.0
250.0
260.0
270.0
280.0
290.0
300.0
310.0
320.0
330.0
340.0
350.0
360.0

90.0
29.32
29.32
29.32
28.92
29.08
29.32
29.16
29.40
29.24
28.84
29.24
29.40
29.16
29.32
29.08
28.92
29.32
29.32
29.32
29.32
29.32
28.92
29.08
29.32
29.16
29.40
29.24
28.84
29.24
29.40
29.16
29.32
29.08
28.92
29.32
29.32
29.32

Equipment: GMS1980
Temperature(C): 25.5

GO1512220401

Date: 2015/12/23
Humidity(%): 60.0%

www.GO-SAFETY.com.tw

Operator: Johnson Wang


Distance(m): 9.00

Page : 13/13