Substation Controller: GE Digital Energy

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8
At a glance
Powered by AI
The document discusses the benefits of the GE D20MX Substation Controller including backwards compatibility, modular hardware, simplified migration of applications, and cyber security features.

The D20MX Substation Controller offers benefits such as reducing legacy D20 RTU upgrade costs by over 50%, minimizing operation and maintenance costs, and introducing modern network security features to enable compliance with NERC-CIP requirements.

The D20MX Substation Controller can execute communications and energy management applications for monitoring and controlling electrical substations. It can amalgamate data from multiple devices, execute local logic, process data through applications, and report results to master stations via different protocols.

GE

Digital Energy

D20MX

Substation Controller
Simple to Advanced Substation
Automation Control
Distribution and transmission industries are under pressure to ensure that their grids
are reliable and to prolong the usability of their assets. Data from these assets can be
collected, aggregated and processed, to provide visibility of system conditions. The MultilinTM
D20MX Substation Controller is a specialized computing platform designed to execute
communications and energy management applications for the monitoring and control of
electrical substations. The D20MX is capable of amalgamating data from multiple slave
devices and D20 I/O modules connected via communication channels into a single database
using various protocols. The D20MX can execute local logic, compile data, process it through
one of multiple applications and report the results upstream to master stations through
different server protocols.
The D20MX represents the next innovation in GEs cyber secure RTU technology for NERCCIP environments. The D20MX is built upon the field-proven Multilin D20 technologies and
continues the tradition of reliable automation and control through high quality and long term
product availability.

Key Benefits
Reduces legacy D20 RTU upgrade expenditures by over 50% through backwards
compatibility with existing D20 installed accessories, such as chassis, modems and D20 I/O
peripheral modules

Economical Life Extension


Backwards compatibility with earlier vintages of D20
RTU chassis including VME and non-VME versions,
reducing upgrade costs of wiring and training
Modular hardware platform combines functions onto
a single board, simplifies ordering, eliminates add-on
expansion memory cards and cables, and decreases
service time and maintenance effort
Employs super capacitors instead of lithium batteries,
extending operation and availability, retaining system
clock and eliminating the need to plan for and replace
dead batteries
Simplified migration of key D20 data collection,
translation and processing applications, minimizing
installation time and training

Cyber Security & Risk Management


Designed for integration into NERC-CIP environments
through native cyber security features

Minimizes operation and maintenance costs of existing D20-based SCADA infrastructure


by leveraging existing designs, processes and infrastructure

Syslog integration into enterprise system assists with


audit compliance

Introduces a new and modern network security feature suite that enables effective
compliance with NERC-CIP requirements through the application of native cyber security
features built into the D20MX Substation Controller

SSH and SFTP provide secure firmware and


configuration file transfer

Applications
Data Concentrator
Automatically consolidates collected information from intelligent electrical devices (IEDs), such
as relays and meters, and communicates to SCADA, EMS, DMS and Data Historian systems

Protocol Converter
Translates different data message formats between devices to support interoperability

Local Automation Platform


Implements popular distribution automation applications such as capacitor bank control,
outage prevention programs, feeder resource optimization and control interlocking, inhibition
and subgrouping

imagination at work

Open standard cyber security allows interoperability


with other IT infrastructures

Flexible and Reliable Operations


Configurable single and dual-IP options provide two
types of LAN redundancy, with built-in dual Ethernet
communication ports
Supports multiple and simultaneous SCADA protocols
for communication to multiple masters, providing
system design flexibility
Robust advanced automation applications, for
example, Mailbox, Failover and programmable logic
executor data transfer applications, based on over two
decades of successful experience with projects and
implementations in live systems

Multilin D20 MX
Advanced Controller
The Multilin D20MX Substation Controller collects, filters, and sorts data from a wide range of intelligent devices (RTUs, relays, meters) in the substation.
The D20MX preserves original data time stamps for accurate sequence of event (SOE) logs, allowing data from large diverse geographic regions and
time zones to be analyzed in extreme detail. Data can be presented simultaneously to multiple SCADA hosts. The D20MX comes with a built-in suite of
protocols and security applications to facilitate integration with various substation devices and SCADA hosts.
D20MX is the sixth generation of D20 CPUs designed to provide a smooth migration path for D20 users to extend the life of aging D20 systems. It
introduces a new and modern network security feature suite that enables effective compliance with NERC-CIP requirements, using open and trusted
standards and protocols that allow integration with modern cyber security systems and tools.

Advanced Substation Controller Connectivity


Sample Enterprise Protocols:
DNP3 Serial and Ethernet [TCP/UDP/IP]
Tejas V
HR6000/XA-21
Modbus Serial (RTU or ASCII)

SCADA

IEC 101/104

EMS

DMS

DATA HISTORIAN

LG-8979
PG&E

D20MX Media Connectivity:


7 serial ports (RS232)
Built-in dual Ethernet ports
Multilin D20MX

(10/100/1000 Base TX or 100 Base FX)


Dual D.20 communication ports

Sample Device Protocols:


Ethernet Switch

DNP3 Serial and Ethernet[TCP/UDP/IP]


Modbus serial (RTU or ASCII)
IEC 101/104
SEL
IRIG-B Support

Bay Controllers

Protection Relays

IEDs/Meters

D20ME Controller Main Connectivity Applications


GE P/N

VER.

SERVER PROT

GE P/N

VER.

APPLICATIONS

B021-0
A068
A033-5

988
311
211

DNP3 DPA
MODBUS DPA
TEJAS V

A185-0
A009

303
805

LG 8979 DPA
PG&E DPA

A101-0
A199

906
106

IEC 60870-5-101/104
HARRIS 6000/XA-21

GE P/N

VER.

CLIENT PROTOCOLS

B023-0
A059
A078-0
B060-0

754
911
610
210

DNP3 DCA
MODBUS DCA
SEL DCA
IEC 60870-5-101/104 DCA

A030
A035
A118
A184-0
B009
B009
A123-0
A113
A036
A027
A088-0
A027-1
A083-0
B058-0

300
211
103
120
400
310
111
301
421
832
203
321
342
231

ACCUMMULATOR FREEZE DTA


ANALOG REFERENCE DTA
FAILOVER DTA
GENERAL ALARM DTA
MAILBOX DTA
MAILBOX DTA
NGC GENERAL DTA
PROGRAMMABLE SYCHRO CHECK RELAY DTA
PROLOGIC EXECUTOR DTA
SOE LOGGER DTA
SUBSTATION MAINTENANCE DTA
COMMUNICATIONS WATCHDOG
CALCULATOR DTA
IEC 870-5 FT1.2 PRIMARY DATA LINK

B085-0

130

B086-0

131

IEC 60870-5-101 BALANCED MODE DATA


LINK
IEC 60870-5 -104 DATA LINK

GEDigitalEnergy.com

Multilin D20 MX
Upgrade of Legacy D20 RTUs

D20MX Upgrade Process

The Multilin D20MX is more than an RTU. Its a commitment to the


ongoing long term availability of GEs automation products. Utilities
have large investments in hardwired automation systems.
Like everything else, this industrial equipment has a lifecycle that
moves from infancy to normal operation, and eventually to the wear
out stages. As a piece of equipment ages it fails more frequently, takes
longer to repair, and eventually reaches the end of its life. Re-design
and forklift replacements require utilities to re-engineer substation
designs, replace field wiring, and retrain staff to manage and maintain
the system, which is a costly endeavor.

The Multilin D20MX provides a cost-effective alternative to upgrades


of legacy D20 RTUs. This means that the investments made in GEs
automation systems keep paying dividends beyond their originally
projected end of life. Simply replace the failed or end of life Multilin
D20 processor module with a Multilin D20MX and migrate the device
configuration to extend the life of the existing D20 Controller. Add
cyber security features for integration into NERC-CIP environments.
As technology changes with market demands, GE continues to invest
in a partnership with their customers through advanced modular
design principals.

RTU UPGRADE SOLUTION

Full replacement of
existing D20 Unit
and existing I/O
modules

D20MX UPGRADE SOLUTION

Upgrade CPU to
D20MX
Retain existingI/O
modules

Retain I/O infrastructure


Replace central
Minimize
Migrate to modern
technologies

INSTALLATION COST

Modify field wiring


Modify engineering
drawings
Building expansion
Marshaling panels
OutagesOUTAGES

Yes
Yes

Not required
Not required

May be required
May be required
Yes

Not required
Not required
Minimal

Yes

Not required

Yes

Minimal

Unknown

Yes

Unknown

Modern open industry


standards

MAINTENANCE

Modify operation
processes
Retrain operations
personnelR
CYBER SECURITY

Built-in cyber security


features
Proprietary solutions

Integration of D20 Substation Controllers into NERC-CIP Environments


The Multilin D20MX supports a comprehensive set of security functions
to allow a seamless integration with existing IT department policies.
Built-in cyber security features, such as Remote Authentication Dial-In
User Service (RADIUS), Role Based Access Control (RBAC), and user
activity logging, provide a complete security toolkit required to enable
effective compliance with NERC-CIP requirements, using open and
trusted standards and protocols, that allow integration with modern
cyber security systems and tools.

RADIUS
RADIUS is a client/server networking protocol that provides centralized
authentication, authorization, and accounting (AAA) management for
computers to connect and use a network service. With RADIUS each
user in your system has their own unique identification login, allowing
you to control who gets access to what devices from where. RADIUS
provides centralized AAA management for computers to connect to the
D20MX.

If one of the current users of your D20MX leaves your company, you
can lock down access to all the devices in your network from a central
location. That user instantly loses access to every D20MX, while other
users remain able to do their jobs without any adverse effects and
costly password change programs.

AAA Network Access


Radius servers use the AAA concept to manage network access by
following a few steps referred to as AAA transactions.

Authentication
The user sends a request to gain access to a particular resource using
access credentials, typically, in the form of user name and password.
The RADIUS server verifies the users credentials and accepts or rejects
access. The D20MX supports primary and secondary RADIUS servers.
If for any reason the D20MX is not able to authenticate the user against
the RADIUS servers, the D20MX verifies the users credentials against
local password files.

GEDigitalEnergy.com

Multilin D20 MX
Authorization
In a typical centralized user authentication system, access terms are
defined on a per user basis. For example, the following authorization
attributes may be associated for a specific user:
Specific D20MX IP address to be accessed by the user
Role ID assigned to the user, where role ID defines which commands
and displays the user is able to access on the D20MX
Allowed time-of-day during which users can access the network

Accounting
When access is granted to the user, their activity can be registered
for security, system integrity monitoring and statistical purposes. For
example, the following users activity can be recorded:
User information
Login time stamp

DESCRPTION

ADMIN

ENGINEER

OPERATOR

OBSERVER

CAN CHANGE
PASSWORD

YES

NO

NO

NO

CAN CLEAR LOGIN


BUFFER

NO

NO

NO

NO

CAN CHANGE SCADA

YES

YES

NO

NO

CAN DOWNLOAD
FIRMWARE

YES

YES

NO

NO

CAN PERFORM
OPERATIONAL
CONTROL
(E.G.: BREAKER
OPERATIONS)

YES

YES

YES

NO

CAN VIEW
OPERATIONAL DATA

YES

YES

YES

YES

Logout time stamp

Advanced Automation

The D20MX provides accounting information by logging the users


activity to a remote syslog server.

Since releasing the first generation D20 back in 1988, GEs automation
experts have learned a lot. Through challenging projects and installations
across the globe, the D20 has evolved into a leader in substation
automation. The culmination of that experience is the sixth generation,
the Multilin D20MX. The following are a sample of the advanced
automation features available today.

RBAC
RBAC is achieved using RADIUS or the D20MXs internal database,
ensuring only authenticated and authorized users gain access to the
system.
When you configure the D20MX to use RADIUS, each D20MX
user is identified by a role ID, which is an integer number
provided by the RADIUS server. The D20MX makes your life
easier by including a pre-configured default RBAC model.
When using RADIUS, revoking user privileges system-wide is as simple
as updating the centralized user database, saving you time and money.

Substation Maintenance
If there is one thing operators hate, its false alarms. The D20MX can
suppress reporting of input points while they are unavailable during
maintenance. This allows users to disable groups of analog and digital
input points by ignoring their actual data and quality changes within
selected applications. While points are suppressed, a predefined
suppression value and the point suppression quality flag are provided
instead. This is useful during maintenance operations to prevent spurious
OFFLINE alarms and inaccurate readings while devices are powered off
or disconnected during the execution of maintenance activities.

Centralized Authentication and Authorization


USER
1. Login attempt

D20MX

NETWORK CONNECTION

RADIUS SERVER

2. D20MX RADIUS client sends users


credentials to RADIUS server

3. Valid user RADIUS server accepts user

4. Invalid user RADIUS server rejects user

GEDigitalEnergy.com

Multilin D20 MX
Accumulator Freeze
Monitoring constantly incrementing and changing values, such as time
of use, and energy consumption across a system, makes accurate
comparisons of data a time-consuming effort . GEs accumulator
freeze application simplifies this process automatically by capturing
the instantaneous value of accumulator records across the system
at the same point in time, giving engineers and operators a clear
understanding of the state of their system.
A popular example of the use of accumulators is energy metering,
where pulse streams from meter pulse generators is proportional to
energy flow. This feature allows users to define groups of accumulator
points whose values are frozen periodically or on demand.

Alarm Management
The D20MX manages alarms based on real substation experience. This
application allows user-defined logical grouping of individual digital
inputs to generate general alarms based on the status of the signals
monitored within each group. Alarm groups are user-definable, with up
to 32766 groups allowed. Status inputs may belong to as many groups
as required.
The great flexibility of this application ensures that each group has its
own meaningful description and configurable latching or non-latching
operation modes. Latching alarms require operator acknowledgement
for optimized management of critical conditions in the system.

System Redundancy
Although the D20 family of RTUs is legendary for quality, GE has
prepared for those rare cases when a processor is unable to function.
Through time tested and utility accepted redundancy mechanisms,
the D20MX is designed for high availability requirements. In redundant
processor mode, one device stands waiting, ready to take over, should
the other unit stop functioning.

automatically synchronized between the two systems. Serial


communication links are automatically switched between the units
based on system health.
The D20MX has redundant Ethernet, enabling automatic switchover
between two sets of Ethernet switches, ensuring there is no single point
of failure in the system.

Control Lockout
The control lockout feature ensures that only a single master station
can access a group of controls at one time, and can lock out groups of
controls to allow for safer local maintenance. Users can create custom
control groups. Any digital output can be included in any control group.

Analog Inputs Monitoring


GEs analog reference provides enhanced and simplified monitoring of
analog input monitoring equipment. Operators define a reference value
used to compare against monitored signals. The application reports
failures in analog input hardware, allowing effective maintenance of the
monitoring devices, reduced downtime and increased reliability of the
system.

SGConfig Setup Software


The Multilin SGConfig software integrates support for the complete
portfolio of GEs Substation Controllers, including the D20MX series. The
SGConfig software introduces an updated graphical user interface while
maintaining configuration processes and workflows available in the
ConfigPro setup software.
Convenient access to product documentation and screencasts is
provided directly from the SGConfig software. (Screencasts are short
instruction videos on popular setup processes.)

Dual D20MX units can be deployed, creating a redundant system where


accumulators, SOE logs, and configurations are

Typical Architecture for Redundant D20 Substation Control System


SCADA Masters

WAN
RS232 Switch
RS232 Communications

D20MX

D20MX

WIRED I/O

Ethernet Switch A

LAN A
LAN B
Substation IED

Substation IED

Substation IED

Ethernet Switch B

GEDigitalEnergy.com

Multilin D20 MX
Hardware Overview
Fully Equipped Out-of-the Box

Backwards Compatibility

Previous generations of D20 RTUs required add-on system components


and software to support Ethernet communications and optional
memory expansion. The new D20MX is equipped by default with
integrated memory, 10/100/1000BASE-TX or 100BASE-FX IEEE
802.3 compliant communications and a core load firmware with a
comprehensive set of key substation automation applications.

The Multilin D20MX is an embedded single board computer powered by


a 667 Mhz power PC CPU pin-for-pin compatible unit with existing D20
VME and non-VME D20 processors and accessories, such as chassis,
D20 remote I/O peripherals, modems.

PCI mezzanine card site


for future expansion

Compatible with classic VME


and non-VME D20 chassis

Built-in 2 x 10/100/1000BaseTX or
2 x 100Base FX Ethernet ports

Super capacitor enables


maintenance-free, battery-less
operation

Integrated CPU, memory,


Ethernet and media interface
in a single D20MX processor

Technical Specifications
SYSTEM

ELECTRICAL

PROCESSOR: 667 MHz embedded PowerQUICC II Pro


MEMORY
1024 MB of 266 MHz DDR2 RAM with ECC
16 MB NVRAM for persistent event storage

100 to 300 V DC (10%) 143 W


output maximum

256 MB firmware flash

Minimum/Maximum DC voltage:

OPERATING SYSTEM: VxWorks

88 V DC / 330 V DC

LED INDICATORS
System status: Power, Ready

DC-DC: 20 to 55 V DC (10%) 135 W


maximum

Ethernet port status: Link and Activity status per port

Minimum/Maximum DC voltage:

Power supply: Power

18 V DC / 60 V DC

IRIG: Flashes when active

PEAK INRUSH CURRENT AT 25 C ON COLD START


AC-DC : 50 A, max at 230 V AC

COMMUNICATIONS
NETWORK CONNECTIONS
Dual redundant Ethernet interface

DC-DC: 50 A, max at 230 V AC


RATED FREQUENCY:

Twisted Pair

10/100/1000BaseTX (Isolated RJ-45 connector)

SERIAL COMMUNICATIONS
D.20 Link, 2 channels
Data rate: 250 kbps

Data rate: 19200 (default)

50/60 Hz nominal (47 to 63 Hz)


(AC/DC)PHYSI

Note: Do not operate the D20MX above 60C for extended


periods of time as this will shorten the life of the super capacitor
and reduce the backup time of the real time clock.
HUMIDITY RATING: 5% to 95% relative humidity, non-

condensing
ENVIRONMENTAL RATING
INGRESS PROTECTION: IP30 (IEC 60529)
INSTALLATION/OVERVOLTAGE CATEGORY: CAT II (2)
POLLUTION DEGREE: 2
USE: Indoor use only
OPERATING ALTITUDE:

Maximum altitude 3000 m [9480 feet]


above sea level

MTBF (MIL-HDBK-217): D20MX Processor Board


Non-VME with 10/100/1000BASE-TX copper: 449,616 hours
at 40C
Non-VME with 100BASE-FX fiber optic: 265,657 hours at
40C
SOFTWARE

OVERALL HEIGHT:

40.34 mm (1.588 in.)

WIDTH:

261.87 mm (10.31 in.)

DEPTH:

160 mm (6.3 in.)

D20MX WEIGHT:

0.7 kg (1.65 lb.)

FIBER CARD WEIGHT: 0.2 kg (0.35 lb.)

Surge protected to 2000 V peak


RS-232, 7 CHANNELS
5-signal (TXD, RXD, RTS#, CTS#, DCD#) DTE ports

2-signal (TXD, RXD)

OPERATING TEMPERATURE: 0C to +70C

PHYSICAL

100BaseFX (Fiber Optic: 1300 nm, 50/125 m, 62.5/125


m multi-mode duplex fiber cable, ST connectors)

MAINTENANCE PORT
RS-232, 1 channel/ 2 ports

Minimum/Maximum AC voltage:
90V AC / 265 V AC

STORAGE
8 MB boot flash

Data rate: independently-selectable; refer to the


application configuration guides.

ENVIRONMENTAL

RATED POWER SUPPLIES


AC-DC: 100 to 240 V AC (10%) 143 W
output maximum

BATTERY SHIPPING RESTRICTIONS


The D20MX does not contain a battery and is therefore not
affected by US DOT or ICAO shipping restrictions.

CONFIGURATION: Performed using SGConfig 7 and



higher
SOE TIME STAMP ACCURACY
TIME SYNC: IRIG-B
TEST
Status point on D20S peripheral toggled at 1 pulse per second,
synchronized to a GPS time signal.
D20MX running under load.

MATERIAL/FINISH:

Galvannealed steel with black


power coat

KIT PACKAGE
LENGTH:

49.5 cm (19.5 in.)

PERFORMANCE
99% of 1 pulse per second events are within 1 ms, and 100%
of the events are within 2 ms over a 15 hour period.

WIDTH:

34.3 cm (13.5 in.)

HEIGHT:

15.2 cm (6 in.)

WEIGHT:

2.54 kg (5.6 lb.)

GEDigitalEnergy.com

Multilin D20 MX
Standards & Protection
EMISSION
EN55011 (CISPR 11)

ISM RF equipment Electromagnetic disturbance characteristics

Radiated Emissions 30 MHz to 1 GHz


Conducted Emissions 150 kHz 30 MHz

IMMUNITY
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 60255-22-6
IEC 60255-22-1
IEC 61000-4-8
IEC 61000-4-9
IEC 60255-22-1
IEC 61000-4-11
IEC 61000-4-16
IEC 61000-4-17
IEC 61000-4-29+

Electrostatic discharge (ESD) immunity test


Radiated, radio-frequency electromagnetic field immunity test
Electrical fast transient/burst immunity test
Surge immunity test
Immunity to conducted disturbances, induced by radio- frequency fields
1 MHz burst immunity test
Power frequency magnetic field immunity test
Pulse magnetic field immunity test
Damped Oscillatory and Ring wave
Voltage dips, short interruptions and voltage variations immunity tests
Test for immunity to conducted, common mode disturbances in the
frequency range 0 Hz to 150 kHz
Ripple on DC input power port immunity test
Voltage dips, short interruptions and voltage variations on DC input
power port immunity test This standard only applies when using high
voltage DC as the source (100 V DC to300 V DC).

SAFETY
EC 61010-1
IEC 60255-5

Safety requirements for electrical equipment for measurement, control


and laboratory use - General requirements
Insulation coordination for measuring relays and protection
equipment- Requirements and tests

Dielectric and Resistance measurements not applicable


due todesign (TVS in circuit)

ENVIRONMENTAL
IEC 60068-2-1

Cold

IEC 60068-2-22
IEC 60068-2-6

Dry Heat
Vibration (sinusoidal)

IEC 60068-2-27

Shock - Operating Response Test Shock - Non-Operating With- stand


Test

IEC 60068-2-29

Bump Non operating test

IEC 60068-2-30
IEC 60068-2-31

Damp heat, cyclic (12 h + 12 h cycle)


Drop and topple

IEC 60068-2-78

Humidity Testing

GEDigitalEnergy.com

2 hours non powered, soak at -40 C, then warm to


-20 C and leave powered for 16 hours
16 hours powered at +70 C
A logarithmic sweep from 10 Hz to 150 Hz to 10 Hz at
1 oct/ min for 1 sweep cycle in the 3 orthogonal axes.
Acceleration level 1 g
Pulse shape: Half sine Pulse duration: 11 ms
- Operating Response Test: Acceleration level: 5 gs
- Non-Operating Withstand Test: Acceleration level:15 gs
- 3 pulses per polarity per axis for a total of 18 pulses
Pulse shape: Half sine Pulse duration: 11 ms
Acceleration level: 10 gs 1000 pulses per polarity per
axis for a total of 6000 pulses
Dropping on each face Dropping on each corner
Toppling (or pushover) For a total of 12 drops
96 hours steady state humidity at 40 C and 93% RH

Ordering Codes
Multilin D20MX
D20MX

CPU Options

D20MX non-VME, dual 10/100/1000BASE-TX Ethernet Ports (front access)

D20MX non-VME dual 100BASE-FX Ethernet Ports (front access)

G
Power Supply

Description

D20MX non-VME, dual 100BASE-FX Ethernet Ports (rear access)


U

Not required

20-60VDC Input, 24V ISO Output

20-60VDC Input, 48V ISO Output

100-300VDC/85-264VAC Input, 24V ISO Output

D
Modem Slots

100-300VDC/85-264VAC Input, 48V ISO Output


U

Empty slot with cover plate

Wesdac D20 202 bin modem

Telenetics 14400 baud modem 2-wire dial up

Telenetics 14400 baud modem 4-wire leased line

D20MX dual 100BASE-FX ST Media Interface Card

Serial Termination Panel

19" Rack Mount Serial IO Westerm Panel

D20 Chassis Mounted Serial IO Westerm Panel

C
D20MX Firmware v1.20

D20 Chassis Mounted Serial IO Westerm Panel w/Extended Bracket


B

D20MX Classic Applications License

D20MX firmware v1.20


U

Not required

A
Future Feature

Classic applications required


U

Future Feature

Not required
U

Future Feature

Not required
U

Not required

Description

Upgrade Kits Order Codes


D20MXK

D20MX Kit Type

Upgrade Kit for D20 Horizontal Chassis

C
D20MX CPU Options

D20MX CPU only


A

D20MX non-VME, dual 10/100/1000BASE-TX Ethernet Ports (front access)

D20MX non-VME dual 100BASE-FX Ethernet Ports (front access)

G
Media Interface Card Options

D20MX non-VME, dual 100BASE-FX Ethernet Ports (rear access)


U

Not required

E
D20MX Firmware v1.20

D20MX dual 100BASE-FX ST Media Interface Card


B

D20MX Classic Applications License

D20MX firmware v1.20


U

Not required

A
Future Feature

Classic applications required


U

Future Feature

Not required
U

Future Feature

Not required
U

Not required

D2X Classic Applications


APPLICATION ID

NAME

A009
A003-5
A036N

PG&E DPA
TEJAS V DPA
PROLOGIC EXECUTOR DTA

A113
A185-0

PSR DCA
8979 DPA

A199-0
A199

HR6000/XA-21
HARRIS 6000/XA-21

Upgrade kits include the necessary items required to upgrade existing D20 RTUs including:
New D20MX CPU [526-3001 or 526-3003 or 526-3005]
Blank Plates [953-1014]
Multilin Products Documentation CD [581-0002]
Multilin D20MX Documentation CD [588-0075]
Ferrite Core for D20 Power Wiring [460-0073]

Digital Energy
650 Markland St.
Markham, ON
Canada L6C 0M1
Toll Free (NA Only): 1-800-547-8629
Tel: 905-927-7070
Fax: 905-927-5098
[email protected]

GEDigitalEnergy.com

0V Cable [975-1237]

Copyright 2013, General Electric Company. All Rights Reserved.

Null Modem Cable [977-0529]

GE reserves the right to make changes to specifications of products described at any


time without notice and without obligation to notify any person of such changes.

GE, the GE monogram, Multilin and D.20 are trademarks of General Electric Company.

imagination at work

GEA-12711C(E)
English
130812

You might also like