0% found this document useful (0 votes)
329 views8 pages

Base Plate

This document provides details for designing the fixed base connection of a column. It includes the geometry of the column, base plate, anchor bolts, and concrete footing. Loads applied include axial force, shear forces, and bending moments. Resistance calculations are presented for the compression zone in the concrete, tension zone with anchor bolt failure modes, and bending of the base plate. The design complies with Eurocode standards for structural steel, concrete, and anchorages. Key values calculated include the bearing resistance of the concrete, tensile resistance of the anchor bolts, and plastic resistance of the base plate to bending.

Uploaded by

IMJ J
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
329 views8 pages

Base Plate

This document provides details for designing the fixed base connection of a column. It includes the geometry of the column, base plate, anchor bolts, and concrete footing. Loads applied include axial force, shear forces, and bending moments. Resistance calculations are presented for the compression zone in the concrete, tension zone with anchor bolt failure modes, and bending of the base plate. The design complies with Eurocode standards for structural steel, concrete, and anchorages. Key values calculated include the bearing resistance of the concrete, tensile resistance of the anchor bolts, and plastic resistance of the base plate to bending.

Uploaded by

IMJ J
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Page 1 of 8

Autodesk Robot Structural Analysis Professional 2015

Fixed column base design


Eurocode 3: EN 1993-1-8:2005/AC:2009 + CEB Design Guide: Design of fastenings in
concrete

Ratio
0.99

GENERAL
1
Connection no.:
Connection name: Fixed column base

GEOMETRY
COLUMN
Section: 323 Dia
Lc =
5.00

[m]
[Deg]

Column length
Inclination angle

[mm]

Height of column section

[mm]

Width of column section

13

[mm]

Thickness of the web of column section

tfc =

13

[mm]

Thickness of the flange of column section

rc =

[mm]

Radius of column section fillet

121.93

[cm2]

Cross-sectional area of a column

=
hc =

0.0
323

bfc =

323

twc =

Ac =
Iyc =

14718.31
Moment of inertia of the column section
[cm4]
Metal
Steel
- 345 MPa
Material:
fyc =
345.00
[MPa]
Resistance
fuc =
448.00
[MPa]
Yield strength of a material

COLUMN BASE
lpd =

500

[mm]

Length

bpd =

500

[mm]

Width

tpd =

30
[mm]
Thickness
Material: Metal - Steel - 345 MPa
fypd =
345.00
[MPa]
Resistance
fupd =
448.00
[MPa]
Yield strength of a material

ANCHORAGE
The shear plane passes through the UNTHREADED portion of the bolt.
8.8
Class =
Anchor class
fyb =
640.00
[MPa]
Yield strength of the anchor material
fub =
800.00
[MPa]
Tensile strength of the anchor material
d=
As =

30
5.61

[cm2]

Bolt diameter
Effective section area of a bolt

[cm2]

Area of bolt section

Av =

7.07

nH =

nV =

[mm]

Number of bolt columns

Number of bolt rows


Horizontal spacing eHi = 135;135 [mm]
Vertical spacing eVi =

135;135 [mm]

mhtml:file://C:\Users\user.SANDUN\Documents\Autodesk\Output\ra_res.mht

9/5/2016

Page 2 of 8

Anchor dimensions
L1 =

60

[mm]

1000

[mm]

Washer
lwd =

50

[mm]

Length

bwd =

60

[mm]

Width

twd =

10

[mm]

Thickness

ls =

600

[mm]

Length

hs =

200

[mm]

Height

ts =

20

[mm]

Thickness

L2 =

STIFFENER

MATERIAL FACTORS
M0 =

1.00

Partial safety factor

M2 =

1.25

Partial safety factor

C =

1.50

Partial safety factor

SPREAD FOOTING
1500
1500
2000

[mm]
[mm]
[mm]

Spread footing length


Spread footing width
Spread footing height

Concrete
Class C30/37
fck =
30.00

[MPa]

Characteristic resistance for compression

L=
B=
H=

Grout layer
tg =

30

[mm]

Thickness of leveling layer (grout)

fck,g =

12.00

[MPa]

Characteristic resistance for compression

Cf,d =

0.30

Coeff. of friction between the base plate and concrete

WELDS
ap =

[mm]

Footing plate of the column base

as =

[mm]

Stiffeners

LOADS
Case: Manual calculations.
Nj,Ed =

-56.00

[kN]

Axial force

Vj,Ed,y =

10.00

[kN]

Shear force

Vj,Ed,z =

10.00

[kN]

Mj,Ed,y =

120.00

[kN*m]

Bending moment

Mj,Ed,z =

31.00

[kN*m]

Bending moment

Shear force

RESULTS
COMPRESSION ZONE
COMPRESSION OF CONCRETE
fcd =
20.00
[MPa]
fj =

40.00

[MPa]

Design compressive resistance


Design bearing resistance under the base plate

EN 1992-1:[3.1.6.(1)]
[6.2.5.(7)]

c = tp (fyp/(3*fj*M0))
c=
beff =
leff =

51
114

[mm]
[mm]

Additional width of the bearing pressure zone


Effective width of the bearing pressure zone under the flange

425

[mm]

Effective length of the bearing pressure zone under the flange

Ac0 =

485.20

[cm2]

Area of the joint between the base plate and the foundation

Ac1 =

4366.76

[6.2.5.(4)]
[6.2.5.(3)]
[6.2.5.(3)]
EN 1992-1:[6.7.(3)]

Maximum design area of load distribution


[cm2]
Frdu = Ac0*fcd*(Ac1/Ac0) 3*Ac0*fcd

EN 1992-1:[6.7.(3)]

Frdu =

EN 1992-1:[6.7.(3)]

j =

2911.17

[kN]

0.67

Bearing resistance of concrete


Reduction factor for compression

[6.2.5.(7)]

Design bearing resistance

[6.2.5.(7)]

fjd = j*Frdu/(beff*leff)
fjd =

40.00

[MPa]

mhtml:file://C:\Users\user.SANDUN\Documents\Autodesk\Output\ra_res.mht

9/5/2016

Page 3 of 8

Ac,n =

1971.98

[cm2]

Bearing area for compression

[6.2.8.2.(1)]

Ac,y =

940.18

[cm2]

Bearing area for bending My

[6.2.8.3.(1)]

Ac,z =

940.18

[cm2]

Bearing area for bending Mz

[6.2.8.3.(1)]

Fc,Rd,i = AC,i*fjd
Fc,Rd,n =

7887.92

[kN]

Bearing resistance of concrete for compression

[6.2.8.2.(1)]

Fc,Rd,y =

3760.71

[kN]

Bearing resistance of concrete for bending My

[6.2.8.3.(1)]

Fc,Rd,z =

3760.71

[kN]

Bearing resistance of concrete for bending Mz

[6.2.8.3.(1)]

COLUMN FLANGE AND WEB IN COMPRESSION


1.00
CL =
Section class
Wpl,y =
3538.31
Plastic section modulus
[cm3]
Mc,Rd,y =
1220.72
[kN*m]
Design resistance of the section for bending
hf,y =

288

EN 1993-1-1:[5.5.2]
EN1993-1-1:[6.2.5.(2)]
EN1993-1-1:[6.2.5]

[mm]

Distance between the centroids of flanges

[6.2.6.7.(1)]

[kN]

Resistance of the compressed flange and web

[6.2.6.7.(1)]

Fc,fc,Rd,y = Mc,Rd,y / hf,y


Fc,fc,Rd,y =

4241.55

Wpl,z =

3538.31

[cm3]

Mc,Rd,z =

1220.72

[kN*m]

hf,z =

288

Plastic section modulus


Design resistance of the section for bending

EN1993-1-1:[6.2.5.(2)]
EN1993-1-1:[6.2.5]

[mm]

Distance between the centroids of flanges

[6.2.6.7.(1)]

[kN]

Resistance of the compressed flange and web

[6.2.6.7.(1)]

Fc,fc,Rd,z = Mc,Rd,z / hf,z


Fc,fc,Rd,z =

4241.55

RESISTANCES OF SPREAD FOOTING IN THE COMPRESSION ZONE


Nj,Rd = Fc,Rd,n
Nj,Rd =

7887.92
[kN]
FC,Rd,y = min(Fc,Rd,y,Fc,fc,Rd,y)

Resistance of a spread footing for axial compression

FC,Rd,y =
3760.71
[kN]
FC,Rd,z = min(Fc,Rd,z,Fc,fc,Rd,z)

Resistance of spread footing in the compression zone

[6.2.8.3]

FC,Rd,z =

Resistance of spread footing in the compression zone

[6.2.8.3]

3760.71

[kN]

[6.2.8.2.(1)]

TENSION ZONE
STEEL FAILURE
Ab =

5.61
[cm2]
800.00
[MPa]
0.85
Beta =
Ft,Rd,s1 = beta*0.9*fub*Ab/M2

Effective anchor area

[Table 3.4]

Tensile strength of the anchor material


Reduction factor of anchor resistance

[Table 3.4]
[3.6.1.(3)]

Ft,Rd,s1 =

Anchor resistance to steel failure

[Table 3.4]

fub =

274.67

Ms =

[kN]

1.20

fyb =

640.00

Partial safety factor


[MPa]

CEB [3.2.3.2]

Yield strength of the anchor material

CEB [9.2.2]

Anchor resistance to steel failure

CEB [9.2.2]

Ft,Rd,s2 = fyb*Ab/Ms
Ft,Rd,s2 =

299.20

[kN]

Ft,Rd,s = min(Ft,Rd,s1,Ft,Rd,s2)
Ft,Rd,s =

274.67

PULL-OUT FAILURE
fck =
30.00

[kN]

[MPa]

Anchor resistance to steel failure

Characteristic compressive strength of concrete

EN 1992-1:[3.1.2]

fctd = 0.7*0.3*fck2/3/C
fctd =

1.35

Design tensile resistance

EN 1992-1:[8.4.2.(2)]

1 =

1.00

Coeff. related to the quality of the bond conditions and concreting conditions

EN 1992-1:[8.4.2.(2)]

2 =

1.00

Coeff. related to the bar diameter

EN 1992-1:[8.4.2.(2)]

[MPa]

fbd = 2.25*1*2*fctd
fbd =

3.04

[MPa]

Design value of the ultimate bond stress

EN 1992-1:[8.4.2.(2)]

hef =

1000

[mm]

Effective anchorage depth

EN 1992-1:[8.4.2.(2)]

[kN]

Design uplift capacity

EN 1992-1:[8.4.2.(2)]

Ft,Rd,p = *d*hef*fbd
Ft,Rd,p =

286.63

CONCRETE CONE FAILURE


hef =
365
[mm]

Effective anchorage depth

CEB [9.2.4]

NRk,c0 = 7.5[N0.5/mm0.5]*fck*hef1.5
NRk,c0 =
scr,N =

286.46

[kN]

Characteristic resistance of an anchor

CEB [9.2.4]

1095

[mm]

Critical width of the concrete cone

CEB [9.2.4]

mhtml:file://C:\Users\user.SANDUN\Documents\Autodesk\Output\ra_res.mht

9/5/2016

Page 4 of 8

ccr,N =

548

[mm]

Critical edge distance

CEB [9.2.4]

Ac,N0 =

22500.00

[cm2]

Maximum area of concrete cone

CEB [9.2.4]

Ac,N =

22500.00

[cm2]

Actual area of concrete cone

CEB [9.2.4]

Factor related to anchor spacing and edge distance

CEB [9.2.4]

Minimum edge distance from an anchor

CEB [9.2.4]

A,N = Ac,N/Ac,N0
A,N =
1.00
548
c=
[mm]
s,N = 0.7 + 0.3*c/ccr.N 1.0
s,N = 1.00

Factor taking account the influence of edges of the concrete member on the distribution of stresses in the concrete CEB [9.2.4]

ec,N = 1.00

Factor related to distribution of tensile forces acting on anchors

CEB [9.2.4]

re,N = 0.5 + hef[mm]/200 1.0


re,N = 1.00

Shell spalling factor

CEB [9.2.4]

ucr,N = 1.00

Factor taking into account whether the anchorage is in cracked or non-cracked concrete

CEB [9.2.4]

Mc =

Partial safety factor

2.16

CEB [3.2.3.1]

Ft,Rd,c = NRk,c0*A,N*s,N*ec,N*re,N*ucr,N/Mc
Ft,Rd,c =

132.62

[kN]

Design anchor resistance to concrete cone failure

SPLITTING FAILURE
hef =
1000

[mm]

Effective anchorage depth

CEB [9.2.5]

EN 1992-1:[8.4.2.(2)]

NRk,c0 = 7.5[N0.5/mm0.5]*fck*hef1.5
NRk,c0 =

1299.04

[kN]

Design uplift capacity

CEB [9.2.5]

scr,N =

2000

[mm]

Critical width of the concrete cone

CEB [9.2.5]

ccr,N =

1000

[mm]

Critical edge distance

CEB [9.2.5]

Ac,N0 =

57840.25

[cm2]

Maximum area of concrete cone

CEB [9.2.5]

Ac,N =

22500.00

[cm2]

Actual area of concrete cone

CEB [9.2.5]

Factor related to anchor spacing and edge distance

CEB [9.2.5]

Minimum edge distance from an anchor

CEB [9.2.5]

A,N = Ac,N/Ac,N0
A,N =

0.39

548
c=
[mm]
s,N = 0.7 + 0.3*c/ccr.N 1.0
s,N = 0.86

Factor taking account the influence of edges of the concrete member on the distribution of stresses in the concrete CEB [9.2.5]

ec,N = 1.00

Factor related to distribution of tensile forces acting on anchors

CEB [9.2.5]

re,N = 0.5 + hef[mm]/200 1.0


re,N = 1.00

Shell spalling factor

CEB [9.2.5]

ucr,N = 1.00

Factor taking into account whether the anchorage is in cracked or non-cracked concrete

CEB [9.2.5]

h,N = (h/(2*hef))2/3 1.2


h,N =

1.00

Coeff. related to the foundation height

M,sp =

2.16

Partial safety factor

CEB [9.2.5]
CEB [3.2.3.1]

Ft,Rd,sp = NRk,c0*A,N*s,N*ec,N*re,N*ucr,N*h,N/M,sp
Ft,Rd,sp =

202.19

[kN]

Design anchor resistance to splitting of concrete

CEB [9.2.5]

TENSILE RESISTANCE OF AN ANCHOR


Ft,Rd = min(Ft,Rd,s , Ft,Rd,p , Ft,Rd,c , Ft,Rd,sp)
Ft,Rd =

132.62

[kN]

Tensile resistance of an anchor

BENDING OF THE BASE PLATE


Bending moment Mj,Ed,y
leff,1 =

250

[mm]

Effective length for a single bolt for mode 1

[6.2.6.5]

leff,2 =

250
116
19.41

[mm]
[mm]
[kN*m]

Effective length for a single bolt for mode 2


Distance of a bolt from the stiffening edge
Plastic resistance of a plate for mode 1

[6.2.6.5]
[6.2.6.5]
[6.2.4]

19.41

[kN*m]

Plastic resistance of a plate for mode 2

m=
Mpl,1,Rd =
Mpl,2,Rd =

[6.2.4]

FT,1,Rd =

670.18

[kN]

Resistance of a plate for mode 1

[6.2.4]

FT,2,Rd =

391.91

[kN]

Resistance of a plate for mode 2

[6.2.4]

FT,3,Rd =
530.48
[kN]
Resistance of a plate for mode 3
Ft,pl,Rd,y = min(FT,1,Rd , FT,2,Rd , FT,3,Rd)

[6.2.4]

Ft,pl,Rd,y =

[6.2.4]

391.91

[kN]

Tension resistance of a plate

Bending moment Mj,Ed,z


leff,1 =

250

[mm]

Effective length for a single bolt for mode 1

[6.2.6.5]

leff,2 =

250
116
19.41

[mm]
[mm]
[kN*m]

Effective length for a single bolt for mode 2


Distance of a bolt from the stiffening edge
Plastic resistance of a plate for mode 1

[6.2.6.5]
[6.2.6.5]
[6.2.4]

19.41

[kN*m]

Plastic resistance of a plate for mode 2

[6.2.4]

Resistance of a plate for mode 1

[6.2.4]

m=
Mpl,1,Rd =
Mpl,2,Rd =
FT,1,Rd =

670.18

[kN]

mhtml:file://C:\Users\user.SANDUN\Documents\Autodesk\Output\ra_res.mht

9/5/2016

Page 5 of 8

FT,2,Rd =

391.91

Resistance of a plate for mode 2

[6.2.4]

FT,3,Rd =

530.48

[kN]
Resistance of a plate for mode 3
Ft,pl,Rd,z = min(FT,1,Rd , FT,2,Rd , FT,3,Rd)

[6.2.4]

Ft,pl,Rd,z =

391.91

[6.2.4]

[kN]

[kN]

Tension resistance of a plate

RESISTANCES OF SPREAD FOOTING IN THE TENSION ZONE


FT,Rd,y = Ft,pl,Rd,y
FT,Rd,y =

391.91

[kN]

Resistance of a column base in the tension zone

[6.2.8.3]

[kN]

Resistance of a column base in the tension zone

[6.2.8.3]

FT,Rd,z = Ft,pl,Rd,z
FT,Rd,z =

391.91

CONNECTION CAPACITY CHECK


Nj,Ed / Nj,Rd 1,0 (6.24)

0.01 < 1.00

verified

(0.01)

ey =

2143

[mm]

zc,y =

144

[mm]

Axial force eccentricity


Lever arm FC,Rd,y

[6.2.8.1.(2)]

[mm]

Lever arm FT,Rd,y

[6.2.8.1.(3)]

zt,y =
Mj,Rd,y =

203
145.53

[kN*m]

[6.2.8.3]

Connection resistance for bending

Mj,Ed,y / Mj,Rd,y 1,0 (6.23)

0.82 < 1.00

[6.2.8.3]
verified

(0.82)

ez =

554

[mm]

zc,z =

144

[mm]

Axial force eccentricity


Lever arm FC,Rd,z

[6.2.8.1.(2)]

[mm]

Lever arm FT,Rd,z

[6.2.8.1.(3)]

zt,z =
Mj,Rd,z =

203
183.45

[kN*m]

[6.2.8.3]

Connection resistance for bending

[6.2.8.3]

Mj,Ed,z / Mj,Rd,z 1,0 (6.23)

0.17 < 1.00

verified

(0.17)

Mj,Ed,y / Mj,Rd,y + Mj,Ed,z / Mj,Rd,z 1,0

0.99 < 1.00

verified

(0.99)

SHEAR
BEARING PRESSURE OF AN ANCHOR BOLT ONTO THE BASE PLATE
Shear force Vj,Ed,y
d,y = 0.49

Coeff. taking account of the bolt position - in the direction of shear

b,y = 0.49

Coeff. for resistance calculation F1,vb,Rd

[Table 3.4]

k1,y = 2.46

Coeff. taking account of the bolt position - perpendicularly to the direction of shear

[Table 3.4]

[Table 3.4]

F1,vb,Rd,y = k1,y*b,y*fup*d*tp / M2
F1,vb,Rd,y = 392.02

[kN]

Resistance of an anchor bolt for bearing pressure onto the base plate

[6.2.2.(7)]

Shear force Vj,Ed,z


d,z = 0.49

Coeff. taking account of the bolt position - in the direction of shear

b,z = 0.49

Coeff. for resistance calculation F1,vb,Rd

[Table 3.4]

k1,z = 2.46

Coeff. taking account of the bolt position - perpendicularly to the direction of shear

[Table 3.4]

[Table 3.4]

F1,vb,Rd,z = k1,z*b,z*fup*d*tp / M2
F1,vb,Rd,z = 392.02

[kN]

Resistance of an anchor bolt for bearing pressure onto the base plate

SHEAR OF AN ANCHOR BOLT


b =
0.25
Avb =
fub =
M2 =

7.07

[cm2]

800.00

[MPa]

[6.2.2.(7)]

Coeff. for resistance calculation F2,vb,Rd

[6.2.2.(7)]

Area of bolt section

[6.2.2.(7)]

Tensile strength of the anchor material

[6.2.2.(7)]

Partial safety factor

[6.2.2.(7)]

[kN]

Shear resistance of a bolt - without lever arm

[6.2.2.(7)]

[kN*m]

Characteristic bending resistance of an anchor

CEB [9.3.2.2]

Lever arm length

CEB [9.3.2.2]

Partial safety factor

CEB [3.2.3.2]

1.25

F2,vb,Rd = b*fub*Avb/M2
F2,vb,Rd =

112.19

M =

2.00

MRk,s =

1.76

lsm =

60

Ms =

1.20

Factor related to the fastening of an anchor in the foundation


[mm]

CEB [9.3.2.2]

Fv,Rd,sm = M*MRk,s/(lsm*Ms)
Fv,Rd,sm =

48.79

[kN]

Shear resistance of a bolt - with lever arm

CEB [9.3.1]

CONCRETE PRY-OUT FAILURE

mhtml:file://C:\Users\user.SANDUN\Documents\Autodesk\Output\ra_res.mht

9/5/2016

Page 6 of 8

NRk,c =

286.46

Design uplift capacity

CEB [9.2.4]

k3 =

2.00

[kN]

Factor related to the anchor length

CEB [9.3.3]

Mc =

2.16

Partial safety factor

CEB [3.2.3.1]

Fv,Rd,cp = k3*NRk,c/Mc
Fv,Rd,cp =

265.24

[kN]

Concrete resistance for pry-out failure

CEB [9.3.1]

CONCRETE EDGE FAILURE


Shear force Vj,Ed,y
VRk,c,y0 = 1596.06 [kN] Characteristic resistance of an anchor

CEB [9.3.4.(a)]

A,V,y =

0.67

Factor related to anchor spacing and edge distance

h,V,y =

1.00

Factor related to the foundation thickness

CEB [9.3.4.(c)]

s,V,y =

0.90

Factor related to the influence of edges parallel to the shear load direction

CEB [9.3.4.(d)]

ec,V,y =

1.00

Factor taking account a group effect when different shear loads are acting on the individual anchors in a group CEB [9.3.4.(e)]

,V,y =

1.00

Factor related to the angle at which the shear load is applied

CEB [9.3.4.(f)]

ucr,V,y =

1.00

Factor related to the type of edge reinforcement used

CEB [9.3.4.(g)]

Mc =

2.16

Partial safety factor

CEB [9.3.4]

CEB [3.2.3.1]

Fv,Rd,c,y = VRk,c,y0*A,V,y*h,V,y*s,V,y*ec,V,y*,V,y*ucr,V,y/Mc
Fv,Rd,c,y =

443.35

[kN]

Concrete resistance for edge failure

CEB [9.3.1]

Shear force Vj,Ed,z


VRk,c,z0 = 1596.06 [kN] Characteristic resistance of an anchor

CEB [9.3.4.(a)]

A,V,z =

0.67

Factor related to anchor spacing and edge distance

h,V,z =

1.00

Factor related to the foundation thickness

CEB [9.3.4.(c)]

s,V,z =

0.90

Factor related to the influence of edges parallel to the shear load direction

CEB [9.3.4.(d)]

ec,V,z =

1.00

Factor taking account a group effect when different shear loads are acting on the individual anchors in a group CEB [9.3.4.(e)]

,V,z =

1.00

Factor related to the angle at which the shear load is applied

CEB [9.3.4.(f)]

ucr,V,z =

1.00

Factor related to the type of edge reinforcement used

CEB [9.3.4.(g)]

Mc =

2.16

Partial safety factor

CEB [9.3.4]

CEB [3.2.3.1]

Fv,Rd,c,z = VRk,c,z0*A,V,z*h,V,z*s,V,z*ec,V,z*,V,z*ucr,V,z/Mc
Fv,Rd,c,z =

443.35

[kN]

SPLITTING RESISTANCE
Cf,d =
0.30
Nc,Ed =

56.00

Concrete resistance for edge failure

CEB [9.3.1]

Coeff. of friction between the base plate and concrete

[6.2.2.(6)]

[kN]

Compressive force

[6.2.2.(6)]

[kN]

Slip resistance

[6.2.2.(6)]

Ff,Rd = Cf,d*Nc,Ed
Ff,Rd =

16.80

SHEAR CHECK
Vj,Rd,y = nb*min(F1,vb,Rd,y, F2,vb,Rd, Fv,Rd,sm, Fv,Rd,cp, Fv,Rd,c,y) + Ff,Rd
Vj,Rd,y =

602.28

[kN]

Connection resistance for shear

Vj,Ed,y / Vj,Rd,y 1,0

0.02 < 1.00

CEB [9.3.1]
verified

(0.02)

Vj,Rd,z = nb*min(F1,vb,Rd,z, F2,vb,Rd, Fv,Rd,sm, Fv,Rd,cp, Fv,Rd,c,z) + Ff,Rd


Vj,Rd,z =

602.28

[kN]

Connection resistance for shear

CEB [9.3.1]

Vj,Ed,z / Vj,Rd,z 1,0

0.02 < 1.00

verified

(0.02)

Vj,Ed,y / Vj,Rd,y + Vj,Ed,z / Vj,Rd,z 1,0

0.03 < 1.00

verified

(0.03)

STIFFENER CHECK
Radial stiffeners
M1 =
5.97
Q1 =

[kN*m]

Bending moment acting on a stiffener

85.66

[kN]

zs =

56

[mm]

Location of the neutral axis (from the plate base)

Is =

4774.07

[cm4]

Moment of inertia of a stiffener

Shear force acting on a stiffener

d =

3.30

[MPa]

Normal stress on the contact surface between stiffener and plate

EN 1993-1-1:[6.2.1.(5)]

g =

21.71

[MPa]

Normal stress in upper fibers

EN 1993-1-1:[6.2.1.(5)]

=
z =

21.41

[MPa]

Tangent stress in a stiffener

EN 1993-1-1:[6.2.1.(5)]

37.24

[MPa]

Equivalent stress on the contact surface between stiffener and plate

EN 1993-1-1:[6.2.1.(5)]

max (g, / (0.58), z ) / (fyp/M0) 1.0 (6.1)

0.11 < 1.00

verified

mhtml:file://C:\Users\user.SANDUN\Documents\Autodesk\Output\ra_res.mht

(0.11)

9/5/2016

Page 7 of 8

WELDS BETWEEN THE COLUMN AND THE BASE PLATE


=

1.15

[MPa]

Normal stress in a weld

[4.5.3.(7)]

1.15

[MPa]

Perpendicular tangent stress

[4.5.3.(7)]

yII =

0.19

[MPa]

Tangent stress parallel to Vj,Ed,y

[4.5.3.(7)]

zII =

0.19

[MPa]

Tangent stress parallel to Vj,Ed,z

[4.5.3.(7)]

W =

0.90

Resistance-dependent coefficient

[4.5.3.(7)]

/ (0.9*fu/M2)) 1.0 (4.1)

0.00 < 1.00

verified

(0.00)

(2
(2

/ (fu/(W*M2))) 1.0 (4.1)

0.01 < 1.00

verified

(0.01)

/ (fu/(W*M2))) 1.0 (4.1)

0.01 < 1.00

verified

(0.01)

+ 3.0
+ 3.0

(yII2
(zII2

+
+

2))
2))

VERTICAL WELDS OF STIFFENERS


Radial stiffeners
=
39.57

[MPa]

Normal stress in a weld

[4.5.3.(7)]

39.57

[MPa]

Perpendicular tangent stress

[4.5.3.(7)]

II =

26.77

[MPa]

Parallel tangent stress

[4.5.3.(7)]

z =

91.72

[MPa]

Total equivalent stress

[4.5.3.(7)]

W =

0.90

Resistance-dependent coefficient

max (, II * 3, z) / (fu/(W*M2)) 1.0 (4.1)

0.23 < 1.00

[4.5.3.(7)]
verified

(0.23)

TRANSVERSAL WELDS OF STIFFENERS


Radial stiffeners
=
42.78

[MPa]

Normal stress in a weld

[4.5.3.(7)]

42.78

[MPa]

Perpendicular tangent stress

[4.5.3.(7)]

II =

33.22

[MPa]

Parallel tangent stress

[4.5.3.(7)]

z =

103.10

[MPa]

Total equivalent stress

[4.5.3.(7)]

W =

0.90

Resistance-dependent coefficient

max (, II * 3, z) / (fu/(W*M2)) 1.0 (4.1)

0.26 < 1.00

[4.5.3.(7)]
verified

(0.26)

CONNECTION STIFFNESS
Bending moment Mj,Ed,y
beff =

114

[mm]

Effective width of the bearing pressure zone under the flange

[6.2.5.(3)]

leff =

425

[mm]

Effective length of the bearing pressure zone under the flange

[6.2.5.(3)]

k13,y = Ec*(beff*leff)/(1.275*E)
k13,y =
leff =
m=

27

[mm]

Stiffness coeff. of compressed concrete

250
116

[mm]
[mm]

Effective length for a single bolt for mode 2


Distance of a bolt from the stiffening edge

[mm]

Stiffness coeff. of the base plate subjected to tension

[Table 6.11]

325

[mm]

Effective anchorage depth

[Table 6.11]

[mm]

Stiffness coeff. of an anchor subjected to tension

[Table 6.11]

[Table 6.11]
[6.2.6.5]
[6.2.6.5]

k15,y = 0.850*leff*tp3/(m3)
k15,y =
Lb =
k16,y = 1.6*Ab/Lb
k16,y =
0,y =

0.59

Column slenderness

[5.2.2.5.(2)]

Sj,ini,y =

22505.25

[kN*m]

Initial rotational stiffness

[Table 6.12]

Sj,rig,y =

185450.73

[kN*m]

Stiffness of a rigid connection

Sj,ini,y < Sj,rig,y SEMI-RIGID

[5.2.2.5]
[5.2.2.5.(2)]

Bending moment Mj,Ed,z


k13,z = Ec*(Ac,z)/(1.275*E)
k13,z =
leff =
m=

38

[mm]

Stiffness coeff. of compressed concrete

250
116

[mm]
[mm]

Effective length for a single bolt for mode 2


Distance of a bolt from the stiffening edge

[mm]

Stiffness coeff. of the base plate subjected to tension

[Table 6.11]

325

[mm]

Effective anchorage depth

[Table 6.11]

[Table 6.11]
[6.2.6.5]
[6.2.6.5]

k15,z = 0.850*leff*tp3/(m3)
k15,z =
Lb =
k16,z = 1.6*Ab/Lb

mhtml:file://C:\Users\user.SANDUN\Documents\Autodesk\Output\ra_res.mht

9/5/2016

Page 8 of 8

k16,z =

0,z =

[mm]

0.59

Stiffness coeff. of an anchor subjected to tension

[Table 6.11]

Column slenderness

[5.2.2.5.(2)]

Sj,ini,z =

49944.47

[kN*m]

Initial rotational stiffness

Sj,rig,z =

185450.73

[kN*m]

Stiffness of a rigid connection

Sj,ini,z < Sj,rig,z SEMI-RIGID

[6.3.1.(4)]
[5.2.2.5]
[5.2.2.5.(2)]

WEAKEST COMPONENT:
BASE PLATE - BENDING

REMARKS
Stiffeners extend outside contour of the base plate. 600 [mm] > 500 [mm]
0 [mm] >= -11 [mm]
Web weld thickness < 3 mm

Connection conforms to the code

mhtml:file://C:\Users\user.SANDUN\Documents\Autodesk\Output\ra_res.mht

Ratio 0.99

9/5/2016