GYPROCK 500 Red - Book 2011 PDF
GYPROCK 500 Red - Book 2011 PDF
GYPROCK 500 Red - Book 2011 PDF
Sustainability
CSR produces a range of energy efficient building products and systems which
have the potential to reduce heating and cooling costs of homes and buildings,
essentially saving tonnes of greenhouse gases each year. Many of these
products are also produced from recycled materials thus:
Reducing the demand for raw materials
Lowering emissions and pollution during manufacturing
Saving land-fill space.
CSR Guarantee
CSR Building Products guarantees its Gyprock products to be free of defects
in materials and manufacture.
If a CSR product does not meet our standard, we will, at our option, replace or
repair it, supply an equivalent product, or pay for doing one of these.
CSR recommends that only products, components and systems recommended
by it be used. If this is not done, CSR will need to be satisfied that any defect
in its product is attributable to our failure to meet our standard (and not another
cause) before this guarantee applies.
This guarantee excludes all other guarantees and liability for damage or loss
in connection with defects in CSR's product, other than those imposed by
legislation.
A2
Introduction
Ceiling Systems
Services Systems
Index
IN
A3
System Index
Inside back cover
Introduction
Ceiling Systems
Service Systems
Index to Systems
System
N
005
010
015
025
032
035
039
040
043
044
045
046
050
055
060
061
062
075
080
089
090
091
092
093
110
121
122
123
125
126
127
128
129
131
135
150
152
155
165
167
168
170
171
175
178
179
180
185
186
192
193
194
195
196
197
198
206
207
208
212
216
217
218
222
223
225
IN
Index
A3
Page
N
B10
B10
B10
B10
B10
B10
B11
B12
B14
B14
B14
B14
B12
B12
B27
B27
B27
B12
B12
B29
B29
B29
B29
B29
B22
B33
B33
B33
B22
B34
B34
B34
B34
B22
B22
B23
B23
B23
B36
B36
B36
B37
B37
B23
B37
B37
B23
B35
B35
B38
B38
B38
B38
B38
B38
B38
B15
B15
B15
B16
B16
B15
B15
B17
B17
B17
System
N
226
230
231
235
240
241
243
244
248
249
250
255
275
280
290
291
292
293
294
295
296
297
298
305
310
315
320
325
330
335
350
352
354
355
375
380
390
391
392
393
403
410
411
415
419
425
430
450
455
475
480
493
494
495
496
497
498
500
501
502
503
506
507
508
509
510
Page
N
B17
B18
B18
B18
B19
B19
B19
B19
B31
B31
B15
B16
B16
B16
B24
B24
B24
B24
B25
B25
B26
B25
B26
C6
C6
C6
C6
C6
C6
C7
C7
C7
C7
C7
C8
C8
C16
C16
C16
C16
C15
C15
C15
C15
C15
C13
C13
C13
C13
C13
C13
C23
C23
C23
C23
C23
C23
C11
C11
C11
C11
C12
C12
C12
C12
B20
System
N
512
513
515
516
520
521
522
523
526
527
528
530
531
532
533
534
535
540
541
542
543
544
545
548
549
550
551
555
575
580
582
600
601
605
606
610
611
613
614
630
631
632
652
653
654
660
661
662
663
664
665
670
671
672
674
675
677
678
680
681
682
690
693
694
695
696
Page
N
B20
B20
B20
B20
B21
B21
B21
B21
D12
D12
D12
D12
D12
D12
D12
D12
D12
D10
D10
D10
D10
D11
D11
D10
D11
C9
D11
C9
C9
C9
C9
B11
B11
B11
B11
B13
B13
B13
B13
B23
B22
B22
C7
C8
C8
C8
C14
C14
C14
C14
C8
C14
C14
C14
C10
C10
C9
C9
C10
C10
C10
C21
C21
C22
C22
C21
System
N
697
698
722
723
724
730
731
732
737
738
739
760
761
762
763
764
765
766
767
768
769
774
775
776
777
778
779
780
781
783
784
787
788
795
796
797
798
801
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
829
831
832
Page
N
C22
C22
D16
D16
D16
D16
D16
D16
D6
D7
D7
D6
D6
D6
D6
D6
D6
D6
D7
D7
D7
D8
D8
D8
D8
D9
D9
D8
D8
D8
D8
D9
D9
D17
D17
D17
D17
E6
E6
E6
E6
E6
E6
E6
E6
E7
E7
E7
E7
E7
E7
E7
E7
E7
E7
E6
E8
E8
E8
E8
E8
E8
E8
E8
E9
E9
System
Page
N
N
833
E9
834
E9
835
E9
836
E9
837
E9
838
E9
839
E9
841
E10
845
E10
846
E10
847
E10
848
E10
849
E10
851
E14
852
E14
853
E14
856
E14
857
E14
858
E14
859
E14
860
E15
862
E13
863
E13
864
E13
865
E16
866
E16
867
E13
868
E13
870
E12
871
E12
874
E13
875
E13
876
E13
877
E16
878
E16
890
E19
891
E15
892
E15
893
E15
894
E15
900
C17
901
C17
902
C17
903
C17
911
C18
912
C18
915
C18
916
C18
920
C20
921
C20
923
C20
924
C20
925
C20
927
C20
928
C20
940
B32
940+
B32
ExpressWall
941
B32
942
B32
945
B28
946
B28
947
B28
950
E12
951
E12
952
E12
System
N
953
955
958
959
967
968
969
970
971
972
981
982
983
985
986
987
992
993
994
995
997
75PP
75PP-DC
75SS
75SS-DC
Hebel
Powerwall
001
Hebel
Powerwall
Hebel
Powerwall
PF-001
SS01
SS02
SS04
SS08
SS09
SS10
SS11
SS12
SS13
SS17
SS18
SS19
SS20
SS21
SS22
SS23
SS24
SS26
SS30
SS31
SS32
SS33
SS34
SS38
SS39
SS40
SS41
SS42
SS44
SS45
SS46
IN1
Page
N
E12
E12
E11
E11
B31
B31
B31
B30
B30
B30
E17
E17
E17
E17
E17
E18
E18
E18
E18
E18
E18
D13
D13
D14
D14
D15
B35
C19
E11
F4
F4
F4
F5
F5
F5
F5
F5
F5
F5
F6
F6
F6
F6
F6
F6
F6
F6
F7
F7
F7
F7
F7
F7
F7
F8
F8
F8
F4
F4
F4
ACOUSTIC
OPINION
PKA-052
NOTES:
FRL
STUD DEPTH mm
SYSTEM
N
Report/Opinion
WALL LININGS
51
BOTH SIDES
//
1 x 10mm GYPROCK
Plasterboard CD.
CSR 010
BOTH SIDES
//
1 x 13mm GYPROCK
Plasterboard CD.
SIDE ONE
1 x 13mm GYPROCK
AQUACHEK Plasterboard.
//
Check the typical layout illustration for the basic system format.
CSR 015
//
SYSTEM SPECIFICATION
90
102
118
176
WALL THICKNESS mm
77
90
102
118
176
(a) Nil
2 x 13mm GYPROCK
Plasterboard CD.
WALL THICKNESS mm
90
103
115
131
189
(a) Nil
(c) 75
GW Partition
11kg
TYPICAL
LAYOUT
(d) TSB3/ASB3 Polyester
WALL THICKNESS mm
84
96
112
170
Rondo71
DUO Two-way
Steel angle to
Steel Grid Ceiling
support ceiling grid
(a) Nil
37/30 38/31 40/33 41/34 44/38
System
100mm
min 11kg
42/33insulation
43/34 45/36 46/37 48/40
System insulation (b) 50 GW Partition
System
1x 13mm GYPROCK
50mm
/ / Bradford Glasswool Partition batts
SOUNDCHEK
11kg/m3 to extent specified in table.
plasterboard.
The Red
77
(a) Nil
170
SIDE TWO
BOTH SIDES
112
CSR 032
Floor or roof structure.
96
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
//
84
1 x 13mm GYPROCK
Plasterboard CD.
BOTH SIDES
71
(a) Nil
1 x 13mm GYPROCK
Plasterboard CD.
CSR 025
150
SIDE TWO
SIDE ONE
92
WALL THICKNESS mm
CSR 011
76
Rw / Rw+Ctr
(a) Nil
WALL THICKNESS mm
64
CAVITY INFILL
(Refer to Section A)
CSR 005
GYPROCK
Panel
Ceiling
System
WALL THICKNESS mm
77
90
102
118
176
B9
Book
EXTENT OF INSULATION
SYSTEM N
CEILING LININGS
Nil
Entire Ceiling
Rw
CSR FP01
38
44
21
24
25
42
48
49
30
31
31
SYSTEM SPECIFICATION
45
30-35
30-36
30-36
35
35-36
35-36
ACOUSTIC
OPINION
TYPICAL LAYOUT
PKAA031
Check the typical layout illustration for the appropriate system format.
System insulation
100mm
min
System insulation
Ceiling Framing
43/34
46/38
1500mm max.
Entire Ceiling
48/39
53/45
55/47
59/51
60/52
59/51
55/47
60/52
59/51
G3
J-Track
1400mm max.
Stud
50/41
52/44
Mechanical fire
damper tested and
approved for
AS1530.4
47/38
49/40
Main Runner
6 10mm
clearance to
GYPROCK
plasterboard
Suspended Ceiling
Top Cross Rail
Fix cornice to
ceiling only with
Gyprock Cornice
Cement
Furring
Channel
Stud
Stud
Steel studs at
600mm centres
Stud
Rondo angles
mechanically
fixed to studs
GYPROCK
FYRCHEK
plasterboard
Proprietary
intumescent
damper
Spigot to terminate
with break joint
Proprietary extruded
aluminium track
Stud
Steel studs
at 600mm
centres
Finish as required
GYPROCK plasterboard
ceiling fixed to furring
channel at appropriate
centres
Z2
Furring Channel in
normal setout position
Flexible Mastic
A4
CSR FP02
Stud
6mm
clear
of
soffit
Nil
41/32
FIG Z027: INSTALLATION DETAIL FOR FIRE DAMPER IN SHAFT WALL SYSTEM APPRAISAL: CSIRO FCO 2109
Note: Wall/ceiling intersection details require engineers approval where seismic loads are expected.
100mm max.
to first fastener
(Do not fix
through track)
CEILING LININGS
GYPROCK
plasterboard
ceiling
GYPROCK
plasterboard
Perimeter gaps sealed
Studs bottomed
in track
Steel studs
at 600mm
centres
Z22
Section A
Introduction
Contents
A6
Components
A6 A15
Product Properties
A15 A16
A16
Fire Testing
A17
Lining Design
A18 A20
Building Acoustics
A21
A22 A23
Definitions
A24
A5
Introduction to
The Red Book
Components
CSR manufactures and supplies a diverse range of
plasterboard and fibre cement sheets, acoustic panels
and accessories to suit a multitude of wall, ceiling and
encasement applications.
Gyprock Plasterboard Cd is composed of a gypsum
core encased in a heavy duty linerboard. Available with long
edges recessed (RE) to assist in producing a smooth, even
and continuous surface once jointed, in square edge (SE),
and in combination RE/SE. Gyprock Plasterboard CD
incorporates Controlled Density (CD) technology. Gyprock
Plasterboard CD is suitable for internal walls and ceilings.
Gyprock Supaceil is a 10mm thick sheet designed
to span up to 600mm in ceiling applications. Gyprock
Supaceil is composed of a gypsum core encased in a
heavy duty linerboard. Long edges are recessed for flush
jointing. Gyprock Supaceil incorporates CD (Controlled
Density) technology.
Gyprock Soundchek has been designed to provide
increased acoustic resistance in wall and ceiling systems.
Gyprock Soundchek is composed of a high density
gypsum core encased in a heavy duty linerboard. Long
edges are recessed to assist in producing a smooth, even
and continuous surface once jointed. Gyprock Soundchek
is suitable for internal walls and ceilings.
Gyprock Impactchek is high strength plasterboard
designed for impact areas. It is composed of a glass fibre
reinforced gypsum core plus a fibreglass mesh bonded to
the inside of the back face. 13mm IMPACTCHEK is encased
in a violet linerboard and has equivalent fire and acoustic
performance to 13mm Fyrchek. The long edges of both
are recessed for flush jointing.
Gyprock Aquachek is designed for use in lining the
walls of wet areas of residential and commercial buildings.
It is a gypsum plasterboard with a core treated to make it
resistant to moisture and humidity. It is manufactured to
satisfy the requirements of AS2588 Gypsum Plasterboard.
It is encased with light blue linerboard and the long edges
are recessed.
Gyprock Fyrchek can be used in wall and ceiling
systems where an FRL is to be achieved, or where acoustic
performance is required. Gyprock Fyrchek is composed
of a specially processed glass fibre reinforced gypsum core
encased in a heavy duty pink liner board.
Gyprock FyrchekMR is primarily intended for walls and
ceilings in wet area rooms and for soffits and external walls
that must achieve fire resistance. Gyprock Fyrchek MR is
composed of a specially processed glass fibre reinforced
gypsum core which is treated in manufacture to withstand
the effects of moisture, and encased in a heavy duty light
blue liner board.
A6
Superchek
Gyprock Superchek is 10mm plasterboard with a very
dense core and heavy duty facing. It has an impact resistance
designed to withstand the knocks typical of residential
buildings, and has excellent sound resistance. It spans
600mm on ceilings and has a white paper face to assist
paint coverage.
530mm
eC08 Range
590mm
1130mm
1191mm
1200mm
3600mm
A7
Gyprock Cornice
CSR Gyprock manufactures six popular machine made
cornice profiles to cater for many styles and applications.
Please refer to Table A1 in this section for general product
information.
eclipse ClimaPlus
19mm thick mineral
fibre panels with three
edge options.
GYPRoCk
CoVe CoRNICe
GYPRoCk
JAZZ CoRNICe
GYPRoCk
SYMPhoNY CoRNICe
GYPRoCk
CoNCeRTo CoRNICe
GYPRoCk
TeMPo CoRNICe
GYPRoCk
CLASSIC CoRNICe
Impressions
ClimaPlus
15mm thick mineral
fibre panels with three
edge options.
Mars ClimaPlus
19mm thick mineral
fibre/glasswool
panels with three
edge options.
olympia Micro
ClimaPlus
15mm thick mineral
fibre panels with three
edge options.
GYPRoCk ShAdoWSeT
A8
Mass
mm
kg/m2
10
13
10
13
10
10
13
10
13
13
10
13
13
13
6.5
13
16
13
6.5
8.5
6.5
8.5
6.5
7.2
13.0
8.0
10.4
10.3
10.4
9.3
10.5
12.1
4.25
10.5
12.5
10.7
16
13.5
PERFORATED SHEET
13
10.0
25
19.8
Size
COVE CORNICE
CLASSIC CORNICE
TEMPO
CORNICE
Width (mm)
900
1800
2400
1350
2700
3000
1200
3600
4200
9.7kg/m2
14.3kg/m2
18.8kg/m2
Length
+0 to -4mm
Width
+0 to -3mm
Thickness
+0.25 to -0.25mm
3mm
Mass
kg/m2
55
0.7kg/m
70
0.9kg/m
90
1.3kg/m
90
1.2kg/m
90
1.8kg/m
SYMPHONY CORNICE
75
0.9kg/m
CONCERTO CORNICE
90
1.6kg/m
JAZZ CORNICE
75
1.8kg/m
SHADOWSET
105
1.0kg/m
A9
Steel Components
Stud Adhesive
A10
Masonry Adhesive
Gyprock Masonry Adhesive is used to adhere Gyprock
plasterboards to concrete and all masonry substrates.
Fasteners
CSR Gyprock distributes a comprehensive range of ring
shank nails, hot-dip galvanised clouts, and screws for
use with timber and steel framing to accommodate most
installation applications. For exterior applications, refer to the
appropriate installation guide.
A11
1st Layer
2nd Layer
3rd Layer
6.5mm
Plasterboard
10mm
Plasterboard
13mm
Plasterboard
16mm
Plasterboard
13mm + 16mm
Plasterboard
1st Layer
2nd Layer
3rd Layer
6.5mm
Plasterboard
10mm
Plasterboard
13mm
Plasterboard
16mm
Plasterboard
13mm + 16mm
Plasterboard
1st Layer
6mm Wallboard
2nd Layer
9mm Wallboard
13mm Plasterboard +
6/9mm Wallboard over
16mm Plasterboard +
6/9mm Wallboard over
6mm Wallboard +
13/16mm Plasterboard over
9mm Wallboard +
13/16mm Plasterboard over
NOTES:
Type 'W' screws of equivalent length may be used as an alternative to Type S NP when fixing to timber only.
Predrill 9mm and 12mm Wallboard for easier fixing.
Fixings are suitable for internal applications only.
NP
= Needle Point Screws.
DP
= Drill Point Screws.
GAL = Galvanised.
A12
1st Layer
2nd Layer
6.5mm Plasterboard
3rd Layer
10mm Plasterboard
13mm Plasterboard
16mm Plasterboard
13mm + 16mm
Plasterboard
1st Layer
2nd Layer
3rd Layer
6.5mm Plasterboard
10mm Plasterboard
13mm Plasterboard
16mm Plasterboard
13mm + 16mm
Plasterboard
TABLe A8: FIxING FIBRe CeMeNT ANd PLASTeRBoARd To STeeL 0.5 0.8mm BMT
Lining Thickness
1st Layer
6mm Wallboard
2nd Layer
9mm Wallboard
6mm Wallboard +
13/16mm Plasterboard over
9mm Wallboard +
13/16mm Plasterboard over
13mm Plasterboard +
6/9mm Wallboard over
16mm Plasterboard +
6/9mm Wallboard over
TABLe A9: FIxING FIBRe CeMeNT ANd PLASTeRBoARd To STeeL 0.8 2.4mm BMT
Lining Thickness
1st Layer
2nd Layer
6mm Wallboard
9mm Wallboard
6mm Wallboard +
13/16mm Plasterboard over
9mm Wallboard +
13/16mm Plasterboard over
13mm Plasterboard +
6/9mm Wallboard over
16mm Plasterboard +
6/9mm Wallboard over
NOTES:
Predrill 9mm and 12mm Wallboard for easier fixing.
Fixings are suitable for internal applications only.
NP
= Needle Point Screws.
DP
= Drill Point Screws.
GAL = Hot-Dip Galvanised.
A13
Insulation Materials
Abbreviation
25 Fibertex 450
Soundscreen
35kg/m3
Soundscreen
40kg/m3
60 Soundscreen 1.6
75 Soundscreen 2.0
88 Soundscreen 2.5
50 GW Partition 11kg
75 GW Partition 11kg
11kg/m3
50 GW Partition 14kg
14kg/m3
75 GW Partition 14kg
34.0kg/m3
Batt
Batt
6.7kg/m3
TSB2/ASB2 Polyester
TSB3/ASB3 Polyester
TSB4/ASB4 Polyester
TSB5 Polyester
TBL/1025 Polyester
A14
R3.0 (Glasswool)
Thermal Performance
Gyprock and Cemintel products have been tested to
ASTM C518 for thermal performance.
The R values for Gyprock plasterboards are:
10mm plasterboard = 0.04 0.05 m2K/W.
13mm plasterboard = 0.05 0.07 m2K/W.
16mm plasterboard = 0.07 0.09 m2K/W.
The R values for Cemintel products are:
6mm fibre cement = 0.02 m2K/W.
7.5mm fibre cement = 0.03 m2K/W.
9mm fibre cement = 0.03 m2K/W.
Product
Properties
Thermal & Moisture Stability
Gyprock plasterboard and Cemintel fibre cement
products are stable building materials when subjected to the
normal range of interior temperature and humidity conditions.
Thermal coefficient of Linear Expansion ().
Plasterboard: =16.2 x 10 -6 mm (mm/C) in the
temperature range 4C to 38C.
Fibre cement: = 7.5 x 10-6/C.
Final length is calculated as follows:
Lf = Li (1 + T).
The hygrometric coefficient of expansion ().
P l a s t e r b o a rd : = 7 . 2 x 1 0 -6 m m / m m / % R . H .
(5% 90% R.H.). Final length is calculated as follows:
Lf = Li (1 + RH).
Fibre cement: = 0.18% (expansion from equilibrium to
saturated). Final length is calculated Lf = Li x x (% of
saturation).
Internal Moisture
Gyprock plasterboard must not be used where it will be
in contact with liquid water or an atmosphere of constant
relative humidity above 90%.
Gyprock Plasterboard CD, Gyprock Supaceil and
Gyprock Soundchek are designed for use in dry areas only.
A15
Combustibility
Material &
Construction
Standards
CSR Product
ASEA
m2/kg
Group
Number
Report
10 13mm Plasterboard CD
<250
10mm SUPACEIL
<250
10 13mm SOUNDCHEK
<250
Plasterboard Manufacture:
10 13mm AQUACHEK
<250
6.5mm FLEXIBLE
<250
Plasterboard Installation:
<250
13 16mm FYRCHEK
<250
MR
<250
<250
10mm SUPERCHEK
<250
13mm
IMPACTCHEK
<250
13mm
ECO8
<250
<250
<250
CeminSeal Wallboard
<250
<250
10mm
Diamond White
<250
10mm SUPATONE
<250
<250
Ecophon ADVANTAGE
<250
Ecophon FOCUS
<250
Mars
<250
Eclipse
<250
Impressions
<250
Olympia Micro
<250
13 16mm FYRCHEK
Partition
FRESHTONE
NOTES:
ASEA = Average Specific Extinction Area
WFRA 45759
FAR 2781
FH 3619
FH 3621
FH 3623
A16
Fire Testing
Fire resistance testing is conducted to the Australian
Standard AS1530 part 4 Fire Resistance Tests of Elements
of Building Construction.
This standard gives the test method and criteria of failure for
the various elements of construction such as partition walls,
floor/ceilings and roof/ceilings.
Loadbearing
/30/30
30/30/30
/60/60
60/60/60
/90/90
90/90/90
/120/120
120/120/120
/180/180
180/180/180
1200
1100
TEMPERATURE (C)
1000
900
800
700
600
500
0
30
60
90
Structural Adequacy
Integrity
Failure occurs when the specimen develops cracks or
openings through which flames or hot gases can pass.
Insulation
A17
Lining Design
There are a number of methods for ensuring that plasterboard
linings meet end user expectations. For best results, these
should be considered in the planning stages of a project and
be clearly set out in specifications and contract documents.
It is noted in the plasterboard standard AS/NZS2589.1
Gypsum linings Application and Finishing that it is good
practice to construct a reference area of decorated work
to aid in judging quality of walls and ceilings throughout a
project.
Levels of Finish
A Level of Finish sets out the minimum specifications for
installation processes from framing preparation to lining
decoration. The levels are defined in AS/NZS 2589.1, and are
intended to provide builders, installers and their customers
with defined methods and practices necessary to meet the
customers expectations in terms of the Level of Finish.
It is essential to determine the level of finish required before
the frame construction begins, as specific tolerances are
required for frame alignment as well as for plasterboard fixing
and finishing for each of the levels of finish. Unless these
requirements are met throughout construction, it may not be
possible to attain the desired finish level without extensive
corrective measures.
Critical Light
The impression of flatness of plasterboard is influenced by
factors such as the accuracy of the substrate, the fixing
methods, joint formation and finishing textures. A surface
that appears perfectly flat in one lighting condition can
seem uneven in another. Any imperfection or undulation in
a completed lining installation can become obvious under
critical or glancing light, where the incident light from an
artificial or natural source is nearly parallel to the surface.
DECORATION
Wall covering,
Wallpaper or Texture
Paint
Flat/Matt/Satin/
Low Sheen
Pastel/
Mid-tones
Level 3 Finish
A18
Level 4 Finish
Non-critical
Lighting
Semi-gloss/Gloss
Dark tones
Critical
Lighting
Level 5 Finish
Glancing light
Jointing
Shadow zone
Shadow zone
Jointing
Glancing light
A19
Resistance to Impact
Lining
Bending
Strength
Soft Body
Impact
Resistance
Surface
Damage
Resistance
10mm Superchek
13mm Impactchek
10mm Gyprock
plasterboard CD
13mm EC08
Impact
6mm CeminSeal
Wallboard
Plasterboard Lining
Minimum Radius
(Concave)
Minimum Radius
(Convex)
6.5mm Flexible
Plasterboard
450 mm
250 mm
10mm plasterboard
CD
900 mm
900 mm
13mm plasterboard
CD and 10mm
Supaceil
1000 mm
1000 mm
3m
3m
13mm Perforated
Plasterboard sheet
20m
20m
Rondo Flexi-Track
Ceiling Framing
A20
Building
Acoustics
Building acoustics can be separated into sound absorption
and sound transmission.
Sound absorption relates to control of sound that is generated
within a room and how it affects people in that room.
Sound transmission relates to sound that passes through a
dividing element (direct sound, controlled by the elements
sound insulation), and through the surrounding structure
(indirect or flanking transmission).
Methods of controlling noise in buildings can be based on
systems, structure and lining materials and their absorption
and transmission properties.
CSR recommends that an acoustic engineer be consulted
for all projects where acoustics are important.
Flanking Transmission
1
1
4
2
2
3
6
4
2
3
6
5
1
A21
Building
Acoustics in
Practice
System Performance
The Rw, Rw + Ctr and Ln,w + CI values in this manual refer to
expected results of a laboratory test on an element.
Extensive testing over many years has been carried out
by CSR at laboratories including the Commonwealth
Experimental Building Station (later CSIRO) at North Ryde
NSW, National Acoustic Laboratory at Lindfield NSW, CSIRO
Laboratories at Highett, Victoria and even, up to 1978, at
our own NATA registered laboratory. Extensive development
testing has been carried out at Rintoul Laboratories, Seven
Hills NSW since 1995, and some of the systems subsequently
validated at other laboratories.
Performance values provided by PKA Acoustic Consulting
use a prediction system based on these tests, and the
system has been updated to include the most current CSR
sponsored testing. The prediction system has been calibrated
against the round robin European test of a standard
plasterboard wall in 24 European acoustic laboratories, and
has successfully predicted the performance of a calibration
wall for an acoustic laboratory in Brisbane.
As testing from different laboratories can vary (the European
24 laboratory test of the standard plasterboard wall was
Rw47 to Rw52), it is possible that laboratory tests may be 1
to 2 Rw points above a prediction.
All care has been taken with preparation of these predictions
and it is assumed that construction is strictly in accordance
with this manual and relevant Gyprock and Cemintel
installation guides.
Acoustic Integrity
The acoustic integrity of a system can be influenced by the
combination of elements that make up the system. Single
leaf and uninsulated systems are more dependant on high
quality installation, as relatively minor defects can cause
major degradation of the system performance.
Building systems that allow defects to be hidden from view
have a higher chance of gaps being left unsealed, making
them more vulnerable to performance degradation.
The likelihood and effect of defects occurring with typical
systems is shown in Table A14.
TABLe A14: ACouSTIC INTeGRITY
Wall System
A22
Effect of
Defects on
Performance
High
High Degradation
High
High Degradation
Low
High Degradation
Low
Moderate
Degradation
Low
Low Degradation
Chance of
Gaps Being Left
Unsealed
Background Noise
Low levels of noise transmitted from other areas can be
partially obscured by background noise.
Where the background noise level is low, such as in remote
areas, consideration should be given to providing a higher
than standard level of sound insulation.
Va r i a t i o n i n o c c u p a n t p e r c e p t i o n s o f n o i s e ,
e.g. high, medium or low cost housing.
Background noise levels may be very low.
The lack of simplicity in construction could reduce actual
performance.
A23
Definitions
Rw Weighted Sound Reduction Index. A measure of
the sound insulation performance of a building element. Rw
is a laboratory measurement similar to STC.
Rw is measured and calculated using the procedures from
AS1276 and AS1191. The related field measurement is
abbreviated as DnT,w.
The higher the number the better the insulation
performance.
dnT,w Weighted Standardised Field Level difference.
A measurement of the sound insulation performance of a
building element. It describes the difference in noise level on
each side of a wall or floor, and indicates the level of speech
privacy between spaces. It is measured in the field and is
therefore subject to the inherent inaccuracies involved in
such a measurement.
The higher the number the better the insulation
performance.
Ctr A spectrum adaptation value used to modify the sound
insulation performance of a wall or floor. Sound insulation
performance can be described by Rw or the DnT,w but these
are not accurate for all noises, especially for low frequency
bass noise from modern stereo systems. Ctr values are
negative value which is added to either the Rw or DnT,w.
AS/NZS1276 - sets out testing methodologies for the sound
insulation properties of building elements and incorporates
these factors and explains their use.
Smaller negative Ctr values are more favourable than large
negative values.
dB(A) The A-scale and dB(A) noise level are used to
degrade the performance of a sound level meter to simulate
what humans hear. The human ear is not a perfect listening
device, it is poor at hearing low frequency noise. dB(A) is
used to compare measured sound with perceived sound.
A number of noise criteria refer to, and are measured in
dB(A). The larger the dB(A) level the louder the noise.
Ln,w Weighted Normalised Impact Sound Pressure
Level. A measure of the noise impact performance of a
floor/ceiling. It is measured in very controlled conditions
in a laboratory and is characterised by how much impact
sound reaches the receiving room via the ceiling/floor from
a standard tapping machine test.
A24
Section B
Contents
B2 B4
B4
B4 B6
B6 B7
B7 B8
B9 B12
B13
B14 B16
B17 B19
B20 B22
B23 B24
B25 B27
B28
B29
B30 B31
B32
B33 B36
B37
B38 B39
B39 B41
B42
B43
B44
B44
B45
B46
B47 B52
B53 B65
B1
300mm 300mm
max. cts max. cts
300mm 300mm
max. cts max. cts
Boxed
Studs
Stud Size
BMT
Linings (mm)
10
13
16
CSR 080(-/180/180)
10
13
0.5
51
0.75
0.5
64
0.75
1.15
2.77
3.20
3.38
2.60
2.32
2.32
2.91
3.32
3.52
2.60
2.60
2.60
3.33
3.72
3.91
3.30
2.72
2.72
3.93
4.22
4.35
3.60
3.13
3.25
4.17
4.43
4.52
4.30
3.53
3.58
16
2.32
2.60
2.75
3.28
3.59
10
2.37
2.83
3.51
10
2.93
3.61
76
0.55 0.75 1.15
Maximum Wall Height (m)
3.70 4.43 4.65
4.13 5.02 5.22
4.30 5.25 5.42
3.80 4.10 5.00
3.20 3.58 4.05
3.24 3.82 4.05
3.25
3.87
4.05
0.55
92
0.75
1.15
150
0.75 1.15
4.54
4.94
5.18
4.40
3.61
3.61
4.83
5.50
5.71
4.80
4.13
4.18
5.11
5.75
5.92
5.00
4.69
4.69
6.55
6.99
7.19
7.00
5.33
5.37
7.22
7.54
7.65
7.65
6.81
6.81
3.61
4.20
4.69
5.37
6.81
TABLE B2: MAXIMUM WALL HEIGHT WITH RONDO LIPPED STEEL STUDS NON-LOADBEARING WALLS
WALLS OF SHAFTS AND FIRE ISOLATED EXITS (LOAD = 0.35kPa)
Wall Frame and
Lining Configuration
600mm max. cts
300mm 300mm
max. cts max. cts
300mm 300mm
max. cts max. cts
Boxed
Studs
Stud Size
BMT
Linings (mm)
0.5
51
0.75
0.5
64
0.75
1.15
10
2.42
2.55
2.93
3.49
3.70
3.25
3.81
3.81
13
2.81
2.92
3.29
3.75
3.94
3.65
4.43
16
3.00
3.12
3.45
3.84
3.99
3.78
4.62
92
0.75
1.15
150
0.75 1.15
3.81
3.81
3.81
3.81
3.81
4.60
4.39
4.84
5.06
5.71
5.71
4.77
4.60
5.01
5.20
6.37
6.89
CSR 080(-/180/180)
2.60
2.60
3.30
3.60
4.30
3.78
4.10
4.77
4.40
4.80
5.00
6.37
6.89
10
2.07
2.34
2.34
2.80
3.15
2.76
3.20
3.62
3.06
3.70
3.81
3.81
3.81
13
2.07
2.34
2.34
2.80
3.17
2.76
3.37
3.62
3.06
3.70
4.20
4.83
5.53
16
2.07
2.34
2.34
2.90
3.18
2.76
3.41
3.62
3.06
3.70
4.20
4.83
5.53
10
2.14
2.59
3.15
10
2.65
3.26
NOTES:
Deflection Limit is span/240 to a maximum of 30mm, in accordance
with BCA Specification C1.8.
Tabulated heights do not include axial loads (except self weight) or
shelf loading.
Loadings: Table B1 Pultimate = 0.375 kPa, Pservice = 0.25 kPa.
Loadings: Table B2 Pultimate = 0.525 kPa, Pservice = 0.35 kPa.
Walls are not for external applications.
All loadings in accordance with AS1170:2002.
Walls analysed in accordance with AS4600:1996.
Noggings in accordance with Table B3.
Staggered stud walls use 64mm lipped studs in 92mm track with
Gyprock Staggered Stud Clip.
Tables have been prepared by Rondo Building Services Pty Ltd.
B2
76
0.55 0.75 1.15 0.55
Maximum Wall Height (m)
Number of Noggings
(equally spaced)
0
1
1
2
3
0
TABLE B4: MAXIMUM WALL HEIGHT FOR RONDO QUIET STUD WALLS GENERALLY (UDL = 0.25kPa)
Wall Frame and Lining Configuration
Minimum Plasterboard
Thickness (mm)
600
450
10
3.70
4.02
13
4.13
4.41
16
4.30
4.58
Spacing
TABLE B5: MAXIMUM WALL HEIGHT FOR GYPROCK SECURITYWALL SYSTEMS (UDL = 0.25kPa)
Wall Frame and Lining Configuration
Security Panel
3.0
4.0
3.0
5.2
27
50
TABLE B6: MAXIMUM WALL HEIGHT FOR GYPROCK STRATAWALL WITH H-STUDS AT 600mm CENTRES
Wall Type
or
Wind Loading
Pservice
kPa
0.25
3.0
0.25
3.0
or
TABLE B7: MAXIMUM WALL HEIGHT FOR GYPROCK STRATAWALL WITH C-STUDS AT 600mm CENTRES WALL
SYSTEM FRL /60/60
Wall Type
FRL/60/60
Wind
Loading
Pservice
kPa
0.25
0.35
0.50
Stud C64
Stud C76
Stud C92
0.50
0.75
1.15
0.55
0.75
0.55
0.75
13mm GYPROCK
plasterboards
2.72
3.13
3.53
3.20
3.30*
3.30*
3.30*
13mm FYRCHEK
2.72
3.13
3.53
3.20
3.58
3.60*
3.60*
6 or 9mm
CeminSeal
Wallboard
2.72
3.00*
3.00*
3.00*
3.00*
3.00*
3.00*
13mm GYPROCK
plasterboards
2.34
2.80
3.15
2.76
3.20
3.06
3.30*
13mm FYRCHEK
2.34
2.80
3.15
2.76
3.20
3.06
3.60*
6 or 9mm
CeminSeal
Wallboard
2.34
2.80
3.00*
2.76
3.00*
3.00*
3.00*
13mm GYPROCK
plasterboards
1.95
2.47
2.80
2.32
2.73
2.56
2.96
13mm FYRCHEK
1.95
2.47
2.80
2.32
2.73
2.56
2.96
6 or 9mm
CeminSeal
Wallboard
1.95
2.47
2.80
2.32
2.73
2.56
2.96
NOTE: * Height limits apply for FRL /90/90 and FRL 120/120. Refer to N GYP949 Gyprock StrataWall Installation Guide.
B3
TABLE B8:
MAXIMUM PERMITTED WALL HEIGHT/WIDTH FOR
LAMINATED SERVICES SYSTEMS (0.35 kPa)
Wall Height (maximum)
System N
2400
3000
3600
7200
Structural Design
1200
1200
1200
NA
1200
1200
1200
1200
2200
2100
2000
NA
CSR968-SA
3100
2700
2600
1200
CSR969-SA
4200
3200
3000
NA
CSREC 031-S
CSR968-S
CSR967-SA
CSREC 031-SA
Design
Considerations
Introduction
CSR Gyprock and Cemintel steel frame wall systems
use zinc coated steel components with one or more layers
of Gyprock plasterboard and/or Cemintel fibre cement
linings fixed to one or both sides. A wide choice of systems
is available for both fire rated and non-fire rated applications
in non-loadbearing and loadbearing situations.
These wall systems are most often used in internal nonloadbearing applications, including commercial, industrial,
institutional, residential and high-rise residential construction.
Systems are also available for external walls.
B4
Loadbearing Walls
Fire Resistance
The steel frame wall systems in this manual are suitable
for the stated FRL when designed in accordance with the
structural considerations above. Wall system ratings apply
in either direction, unless noted otherwise.
CSR fire rated steel stud wall systems have been designed
with fire protection that limits the temperature of the
steel framing to a maximum of 450C at the FRL stated.
Therefore the structural design of the framing need only
provide for normal temperature conditions, and no additional
consideration of fire rating is required. In some systems this
temperature is exceeded and the axial capacity of the stud
must be reduced to compensate for the loss of strength. The
percentage reduction is noted for each affected systems.
To protect structural steel beams and columns that are
entirely within a wall, the FRL of the wall system must be at
least equivalent to that required by the structural member.
For example, a wall system with FRL 90/90/90 provides FRL
90// for a steel column within the wall.
Framing & Lining
Steel framed walls required to have an FRL must comply
with the following:
B5
Caulking
To attain the specified FRL, all perimeter gaps and
penetrations must be carefully and completely filled with
appropriate caulking material. CSR Gyprock Fire Mastic or
other tested fire and acoustic rated material of equivalent or
better performance must be used.
Vermiculite plaster has no capacity to accommodate building
movement and may not be suitable for use as a general purpose
fire rated caulking. Its use is specified in some wall/ceiling
junctions, refer to brochure NGYP570, Gyprock Ceiling
Systems Installation Guide.
Acoustic Performance
The acoustic performance of wall systems is expressed in
terms of Rw and Rw+Ctr where appropriate. The performance
of the as-built system may be affected by sound flanking, the
effectiveness of workmanship and caulking, the presence
and treatment of penetrations, and the inclusion of structural
elements and bridging items. Refer to Section A for detailed
information on addressing these issues.
General Notes.
The acoustic performance of systems may be adversely
affected by the use of studs with higher BMT or closer
spacings than those specified, or by the use of additional
linings fixed with battens.
In non-fire rated systems, to attain the stated acoustic
performance, use Gyprock Wet Area Acrylic Sealant,
Gyprock Fire Mastic or other tested acoustic rated material
of equivalent or better performance.
The acoustic performance of CSR wall systems is not
adversely affected by:
The order of lining sheets that are fixed direct to framing.
The substitution of Aquachek for Gyprock Plasterboard
CD of the same thickness.
The substitution of Gyprock Fyrchek MR for Fyrchek of
the same thickness.
Installation
Framing
CSR recommends steel components manufactured by
Rondo Building Services Pty Ltd. Additional information
on the steel components can be obtained from the Rondo
Building Services Pty Ltd, telephone 1300 367 663. Other
steel components of equivalent performance may be used,
however, it is the responsibility of the manufacturer of the
component to substantiate equivalent performance with the
recommended component.
For detailed information on wall junctions, intersections, frame
attachments and penetrations, refer to guide NGYP544,
Gyprock Steel Frame Wall Systems.
Shaftwall , SecurityWall , Party Wall, Cinema Wall,
Laminated systems and StrataWall systems have additional
installation details. Refer to the relevant installation guide.
Walls curved in plan may be built with steel stud frames.
Selection information on stud centres and plasterboard
thickness for various curvatures can be found in brochure
NGYP544, Gyprock Steel Frame Wall Systems.
B6
Control Joints
Control joints must be installed to allow for structural
movement. Allowance for movement must be made through
the frame, lining and any tiles.
Components
Lining & Fixing Materials
Framing
CSR recommends steel components manufactured by
Rondo Building Services Pty Ltd. Additional information
on the steel components can be obtained from the Rondo
Building Services Pty Ltd.
Other steel components of equivalent performance may be
used, however, it is the responsibility of the manufacturer of
the component to substantiate equivalent performance with
the recommended component.
External Walls
CSR external wall systems rely on a range of cladding
systems to provide weather resistance. There is a range of
effectiveness of these systems, and CSR recommends the
cladding be installed with a drained cavity. Cavity systems
allow drainage and drying of any water that penetrates, and
are known to have good long-term performance.
Sarking is also recommended to provide additional weather
protection to framing and lining.
External walls require specific design for condensation
control and energy efficiency, depending on the climate and
internal environment. Contact CSR Bradford for information
on thermal insulation systems and products.
Stud
BMT (mm)
51
64
76
92
150
0.50*
0.55*
0.75
1.15
Stud
BMT (mm)
0.55
Length (mm)
2700
3000
3600
Stud BMT
Stud Depth
Length
(mm)
(mm)
(mm)
64CH55
0.55
64
3000 / 3600
64CH90
0.90
64
4500
102CH90
0.55
102
3600 / 4300
102CH90
0.90
102
5500
B7
35.0
35.5
8.0
30
37
Depth
Depth
30
BMT
0.75
BMT
1.15
18
8.0
6.35
35.0
33.5
6mm
92mm
Rondo
64mm
Lipped
Steel
Stud
Rondo
92mm
Track
6mm
43mm
CSR Gyprock
Staggered Stud Clip
5.0
Depth
BMT
0.50/0.55
5.0
35.4
64 or 102mm
25mm
35mm
B8
ACOUSTIC
OPINION
PKA-052
FRL
Report/Opinion
SYSTEM
N
STUD DEPTH mm
WALL LININGS
BOTH SIDES
1 x 10mm GYPROCK
Plasterboard CD.
BOTH SIDES
1 x 13mm GYPROCK
Plasterboard CD.
//
SIDE ONE
1 x 13mm GYPROCK
AQUACHEK Plasterboard.
//
CSR 015
//
WALL THICKNESS mm
77
102
118
176
77
102
118
176
(a) Nil
WALL THICKNESS mm
90
115
131
189
(a) Nil
71
96
112
170
(a) Nil
170
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
112
WALL THICKNESS mm
//
96
2 x 13mm GYPROCK
Plasterboard CD.
BOTH SIDES
84
(a) Nil
CSR 032
71
SIDE TWO
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
//
BOTH SIDES
CSR 025
(a) Nil
1 x 13mm GYPROCK
Plasterboard CD.
1 x 13mm GYPROCK
Plasterboard CD.
150
SIDE TWO
SIDE ONE
92
WALL THICKNESS mm
CSR 011
76
(a) Nil
WALL THICKNESS mm
CSR 010
64
Rw / Rw+Ctr
(Refer to Section A)
CSR 005
//
51
CAVITY INFILL
77
102
118
176
B9
ACOUSTIC
OPINION
PKA-052
FRL
Report/Opinion
SYSTEM
N
STUD DEPTH mm
WALL LININGS
BOTH SIDES
2 x 10mm GYPROCK
SUPERCHEK
plasterboard.
//
CSR 039
91
116
132
190
SIDE TWO
2 x 13mm GYPROCK
SOUNDCHEK
Plasterboard.
SIDE ONE
WALL THICKNESS mm
WALL THICKNESS mm
90
115
131
189
77
102
118
176
(a) Nil
63
88
104
162
(a) Nil
1 x 6mm CeminSeal
Wallboard.
SIDE ONE
1 x 9mm CeminSeal
Wallboard.
1 x 13mm GYPROCK
Plasterboard CD.
BOTH SIDES
(a) Nil
SIDE TWO
CSR 601
B10
WALL THICKNESS mm
//
1 x 6mm CeminSeal
Wallboard.
CSR 605
(a) Nil
BOTH SIDES
//
150
1 x 13mm GYPROCK
SOUNDCHEK
Plasterboard.
CSR 600
//
92
SIDE ONE
1 x 13mm GYPROCK
IMPACTCHEK.
//
76
(a) Nil
WALL THICKNESS mm
CSR 033
64
Rw / Rw+Ctr
(Refer to Section A)
CSR 035
//
51
CAVITY INFILL
69
94
110
168
(a) Nil
SIDE TWO
1 x 13mm GYPROCK
Plasterboard CD.
70
95
111
169
ACOUSTIC
OPINION
PKA-052
FRL
Report/Opinion
SYSTEM
N
CSR 606
STUD DEPTH mm
WALL LININGS
SIDE ONE
/60/60
30/30/30
60/60/60*
FAR2357
WALL THICKNESS mm
/90/90
60/60/60
FAR2357
114
172
77
102
118
176
SIDE TWO
1 x 16mm GYPROCK
FYRCHEK plasterboard
(against studs).
SIDE ONE
89
114
130
188
83
108
124
182
(a) Nil
SIDE TWO
FAR2357
2 x 13mm GYPROCK
FYRCHEK Plasterboard.
1 x 16mm GYPROCK
FYRCHEK Plasterboard.
1 x 13mm GYPROCK
FYRCHEK Plasterboard.
SIDE ONE
(a) Nil
/90/90
and
30/30/30
98
WALL THICKNESS mm
*ACR 5%
From Fyrchek
lined side ONLY
86
1 x 16mm GYPROCK
FYRCHEK plasterboard.
CSR 038
73
1 x 16mm GYPROCK
FYRCHEK Plasterboard.
FAR2357
/60/60
30/30/30
60/60/60*
BOTH SIDES
CSR 040
(a) Nil
CSR 055
*ACR15%
SIDE ONE
1 x 6mm CeminSeal
Wallboard.
/90/90
60/60/60
90/90/90*
(a) Nil
WALL THICKNESS mm
CSR 615
150
1 x 13mm GYPROCK
FYRCHEK plasterboard.
*ACR15%
92
1 x 13mm GYPROCK
Plasterboard CD.
BOTH SIDES
76
(a) Nil
SIDE TWO
CSR 050
64
Rw / Rw+Ctr
(Refer to Section A)
1 x 9mm CeminSeal
Wallboard.
//
51
CAVITY INFILL
WALL THICKNESS mm
90
115
131
189
(a) Nil
SIDE TWO
1 x 13mm GYPROCK
Plasterboard CD.
80
105
121
179
B11
ACOUSTIC
OPINION
PKA-052
FRL
Report/Opinion
SYSTEM
N
STUD DEPTH mm
WALL LININGS
*ACR15%
FAR2357
CAVITY INFILL
CSR 614
1 x 6mm CeminSeal
Wallboard.
1 x 13mm GYPROCK
FYRCHEK plasterboard.
BOTH SIDES
FAR2357
1 x 6mm CeminSeal
Wallboard.
CSR 611
BOTH SIDES
CeminSeal
1 x 6mm
Wallboard (against studs).
1 x 16mm GYPROCK
FYRCHEK plasterboard.
FAR2357
CSR 075
*ACR10%
130
188
95
120
136
194
95
120
136
194
(a) Nil
103
128
144
202
(a) Nil
1 x 9mm CeminSeal
Wallboard.
1 x 16mm GYPROCK
FYRCHEK plasterboard.
101
126
142
200
(a) Nil
BOTH SIDES
2 x 16mm GYPROCK
FYRCHEK plasterboard.
B12
114
2 x 13mm GYPROCK
FYRCHEK plasterboard.
CSR 080
FAR2357
102
(a) Nil
WALL THICKNESS mm
/180/180
and
120/120/120
89
CSR 613
FAR2357
WALL THICKNESS mm
/120/120
90/90/90
BOTH SIDES
FAR2357
(a) Nil
WALL THICKNESS mm
/120/120
90/90/90
120/120/120*
150
*ACR15%
*ACR15%
92
(a) Nil
1 x 16mm GYPROCK
FYRCHEK plasterboard
(against studs).
/120/120
60/60/60
90/90/90*
76
WALL THICKNESS mm
/90/90
60/60/60
90/90/90*
64
Rw / Rw+Ctr
(Refer to Section A)
CSR 610
/90/90
30/30/30
60/60/60*
51
115
140
156
214
ACOUSTIC
OPINION
PKA-052
FRL
Report/Opinion
SYSTEM
N
WALL LININGS
CSR 043
BOTH SIDES
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
//
STUD DEPTH mm
CAVITY INFILL (Refer to Section A)
(a) Nil
42/35
50/41
51/42
49/42
(e) 60
Soundscreen
1.6
WALL THICKNESS mm
CSR 048
BOTH SIDES
2 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
//
CSR 044
/60/60
30/30/30
60/60/60*
BOTH SIDES
1 x 13mm GYPROCK
FYRCHEK plasterboard.
*ACR15%
FAR2357
CSR 045
/90/90
and
30/30/30
FAR2357
49/43
57/49
58/50
56/50
(e) 60
Soundscreen
2.0 batts
58/49
WALL THICKNESS mm
144
(a) Nil
41/34
49/40
51/42
48/41
(e) 60
Soundscreen
2.0 batts
51/41
WALL THICKNESS mm
118
(a) Nil
48/42
56/48
58/50
56/50
(e) 60
Soundscreen
1.6
WALL THICKNESS mm
/90/90
60/60/60
FAR2357
144
48/42
59/48
1 x 16mm GYPROCK
FYRCHEK Plasterboard.
58/50
56/50
(e) 60
Soundscreen
1.6
WALL THICKNESS mm
CSR 049
57/48
(a) Nil
1 x 6mm CeminSeal
Wallboard.
FAR2357
118
CSR 046
*ACR15%
51/41
(a) Nil
2 x 13mm GYPROCK
FYRCHEK Plasterboard.
/90/90
60/60/60
90/90/90*
92
Rw / Rw+Ctr
57/48
136
(a) Nil
45/38
53/44
54/45
SIDE TWO
52/45
2 x 16mm GYPROCK
FYRCHEK Plasterboard.
54/44
SIDE ONE
1 x 16mm GYPROCK
FYRCHEK Plasterboard.
WALL THICKNESS mm
140
B13
ACOUSTIC
OPINION
PKA-052
NOT
Deemed
Discontinuous
Construction
FRL
Report/Opinion
SYSTEM
N
WALL LININGS
CSR 110
BOTH SIDES
1 x 13mm GYPROCK
Plasterboard CD.
//
CAVITY WIDTH mm
CAVITY INFILL (Refer to Section A)
BOTH SIDES
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
//
BOTH SIDES
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
//
38/31
41/34
46/37
48/39
47/38
49/40
45/38
47/40
47/37
49/39
(e) 60
Soundscreen
1.6
118
176
(a) Nil
41/34
44/38
49/40
51/43
50/41
52/44
48/41
50/44
50/40
52/43
112
170
(a) Nil
42/35
45/39
50/41
52/44
51/42
53/45
49/42
51/45
51/41
53/44
118
176
WALL THICKNESS mm
CSR 135
//
SIDE ONE
(a) Nil
44/37
47/40
2 x 10mm GYPROCK
SUPERCHEK
plasterboard.
52/43
54/45
53/44
55/46
51/44
53/46
1.6
53/43
55/45
WALL THICKNESS mm
118
176
(a) Nil
38/31
42/35
46/37
49/40
47/38
50/41
SIDE TWO
45/38
48/41
1 x 6mm CeminSeal
Wallboard.
47/37
50/40
111
169
(a) Nil
39/32
42/35
47/38
49/40
48/39
50/41
46/39
48/41
1.6
48/38
50/40
WALL THICKNESS mm
118
176
SIDE TWO
1 x 6mm CeminSeal
Wallboard.
CSR 631
CSR 632
//
SIDE ONE
1 x 13mm GYPROCK
Plasterboard CD.
//
SIDE ONE
1 x 13mm GYPROCK
Plasterboard CD.
SIDE TWO
1 x 13mm GYPROCK
IMPACTCHEK.
B14
Rw / Rw+Ctr
WALL THICKNESS mm
CSR 131
150
(a) Nil
WALL THICKNESS mm
CSR 125
92
(e) 60
Soundscreen
WALL THICKNESS mm
(e) 60
Soundscreen
ACOUSTIC
OPINION
PKA-052
NOT
Deemed
Discontinuous
Construction
FRL
Report/Opinion
SYSTEM
N
WALL LININGS
CSR 132
BOTH SIDES
2 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
//
CAVITY WIDTH mm
CAVITY INFILL (Refer to Section A)
/60/60
30/30/30
60/60/60*
BOTH SIDES
1 x 13mm GYPROCK
FYRCHEK plasterboard.
*ACR15%
FAR2357
CSR 153
49/43
51/45
58/50
59/51
58/50
59/51
56/50
57/51
58/49
59/50
(e) 60
Soundscreen
1.6
144
202
(a) Nil
41/34
44/38
49/40
51/43
50/41
52/44
48/41
50/44
50/40
52/43
118
176
(a) Nil
50/44
52/46
58/50
59/51
59/51
60/52
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
57/51
58/52
59/50
60/51
150
208
SIDE ONE
(a) Nil
45/38
48/42
2 x 13mm GYPROCK
FYRCHEK plasterboard.
53/44
55/47
54/45
56/48
52/45
54/48
1.6
54/44
56/47
WALL THICKNESS mm
131
189
(a) Nil
41/34
44/38
49/40
51/43
50/41
52/44
48/41
50/44
50/40
52/43
124
182
BOTH SIDES
1 x 16mm GYPROCK
FYRCHEK plasterboard.
*ACR15%
FAR2357
CSR 152
/90/90
30/30/30
SIDE TWO
1 x 13mm GYPROCK
FYRCHEK plasterboard.
FAR2357
CSR 155
/90/90
60/60/60
90/90/90*
BOTH SIDES
1 x 16mm GYPROCK
FYRCHEK plasterboard.
*ACR15%
FAR2357
WALL THICKNESS mm
(e) 60
Soundscreen
WALL THICKNESS mm
(a) Nil
47/41
50/44
55/47
57/49
1 x 6mm CeminSeal
Wallboard.
56/48
58/50
54/48
56/50
1.6
56/47
58/49
WALL THICKNESS mm
130
188
CSR 630
/90/90
30/30/30
60/60/60*
*ACR15%
FAR2357
Rw / Rw+Ctr
WALL THICKNESS mm
/90/90
60/60/60
90/90/90*
150
(a) Nil
WALL THICKNESS mm
CSR 150
92
1 x 13mm GYPROCK
FYRCHEK plasterboard.
(e) 60
Soundscreen
B15
ACOUSTIC
OPINION
PKA-052
TEST
TL461
NOT
Deemed
Discontinuous
Construction
FRL
Report/Opinion
SYSTEM
N
WALL LININGS
CSR 175
/120/120
90/90/90
120/120/120*
BOTH SIDES
2 x 13mm GYPROCK
FYRCHEK plasterboard.
*ACR10%
FAR2357
CAVITY WIDTH mm
CAVITY INFILL (Refer to Section A)
/180/180
120/120/120
FAR2357
B16
BOTH SIDES
2 x 16mm GYPROCK
FYRCHEK plasterboard.
150
Rw / Rw+Ctr
(a) Nil
48/42
50/44
56/48
57/49
58/50
59/51
56/50
57/51
58/50
58/49
144
202
(a) Nil
48/42
50/44
56/48
57/49
58/50
59/51
56/50
57/51
1.6
57/48
58/49
WALL THICKNESS mm
156
214
WALL THICKNESS mm
CSR 180
92
(e) 60
Soundscreen
ACOUSTIC
OPINION
PKA-052
Discontinuous
Construction
FRL
Report/Opinion
SYSTEM
N
CAVITY WIDTH mm
WALL LININGS
CAVITY INFILL
BOTH SIDES
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
CSR 250
BOTH SIDES
1 x 13mm GYPROCK
FYRCHEK plasterboard.
*ACR15%
FAR2357
*ACR15%
46/40
47/41
48/42
53/45
54/46
55/47
56/48
55/47
55/47
56/48
57/49
52/46
53/47
54/48
55/49
54/45
55/46
56/47
57/48
174
226
276
326
(a) Nil
44/38
45/39
46/40
47/41
52/44
53/45
54/46
55/47
54/46
54/46
55/47
56/48
51/45
52/46
53/47
54/48
53/44
54/45
55/46
56/47
174
226
276
326
(a) Nil
50/44
51/45
52/46
53/47
58/50
59/51
60/52
61/53
1 x 13mm GYPROCK
FYRCHEK plasterboard.
60/52
60/52
61/53
62/54
57/51
58/52
59/53
60/54
59/50
60/51
61/52
62/53
186
238
288
338
1 x 6mm CeminSeal
Wallboard.
FAR2357
(e) 60
Soundscreen
1.6
WALL THICKNESS mm
CSR 204
/90/90
30/30/30
FAR2357
SIDE ONE
(a) Nil
50/44
51/45
52/46
53/47
2 x 13mm GYPROCK
FYRCHEK plasterboard.
58/50
59/51
60/52
61/53
60/52
60/52
61/53
62/54
57/51
58/52
59/53
60/54
59/50
60/51
61/52
62/53
193
245
295
345
300
45/39
WALL THICKNESS mm
CSR 207
/90/90
30/30/30
60/60/60*
250
(a) Nil
WALL THICKNESS mm
/60/60
30/30/30
60/60/60*
200
Rw / Rw+Ctr
(Refer to Section A)
CSR 208
//
148
WALL THICKNESS mm
B17
ACOUSTIC
OPINION
PKA-052
Discontinuous
Construction
SYSTEM
N
CSR 217
CAVITY WIDTH mm
WALL LININGS
SIDE ONE
FAR2357
(a) Nil
48/42
49/43
50/44
51/45
60/52
60/52
61/53
62/54
61/53
62/54
63/55
63/55
59/53
60/54
60/54
61/55
1 x 13mm GYPROCK
FYRCHEK plasterboard.
61/52
62/53
62/53
63/54
187
239
289
339
(a) Nil
44/38
45/39
46/40
47/41
56/48
56/48
57/49
58/50
57/49
58/50
59/51
59/51
55/49
56/50
57/51
57/51
57/48
58/49
58/49
59/50
180
232
282
332
49/43
51/45
52/46
52/46
1 x 16mm GYPROCK
FYRCHEK plasterboard.
FAR2357
WALL THICKNESS mm
(e) 2 x 60
Soundscreen
1.6
WALL THICKNESS mm
(a) Nil
CSR 206
/90/90
60/60/60
90/90/90*
*ACR15%
FAR2357
57/49
59/51
60/52
60/52
1 x 10mm GYPROCK
Plasterboard CD.
59/51
60/52
61/53
61/53
1 x 16mm GYPROCK
FYRCHEK plasterboard.
56/50
58/52
59/53
59/53
58/49
60/51
61/52
61/52
200
252
302
352
(a) Nil
44/38
45/39
46/40
47/41
52/44
53/45
54/46
55/47
54/46
54/46
55/47
56/48
51/45
52/46
53/47
54/48
53/44
54/45
55/46
56/47
180
232
282
332
WALL THICKNESS mm
CSR 255
/90/90
60/60/60
90/90/90*
*ACR15%
FAR2357
BOTH SIDES
1 x 16mm GYPROCK
FYRCHEK plasterboard.
(e) 60
Soundscreen
1.6
WALL THICKNESS mm
B18
300
BOTH SIDES
*ACR15%
250
SIDE TWO
CSR 218
/90/90
60/60/60
90/90/90*
200
Rw / Rw+Ctr
(Refer to Section A)
2 x 13mm GYPROCK
FYRCHEK plasterboard.
/90/90
30/30/30
148
CAVITY INFILL
ACOUSTIC
OPINION
PKA-052
TEST
ATF 1740
Discontinuous
Construction
NOTES:
Unless otherwise specified cavity infill is required in one
stud row only.
CSR 216 requires batts in each stud row.
*ACR = Axial Capacity Reduction
FRL
Report/Opinion
SYSTEM
N
CAVITY WIDTH mm
WALL LININGS
BOTH SIDES
2 x 13mm GYPROCK
FYRCHEK plasterboard
*ACR10%
FAR2357
FAR2357
50/44
51/45
52/46
53/47
58/50
59/51
60/52
61/53
60/52
60/52
61/53
62/54
57/51
58/52
59/53
60/54
1.6
59/50
60/51
61/52
62/53
(e) 60
Soundscreen
200
252
302
352
50/44
52/46
53/47
53/47
BOTH SIDES
58/50
60/52
61/53
61/53
1 x 6mm CeminSeal
Wallboard (against studs).
60/52
61/53
62/54
62/54
1 x 16mm GYPROCK
FYRCHEK plasterboard.
57/51
59/53
60/54
60/54
59/50
61/52
62/53
62/53
192
244
294
344
(a) Nil
50/44
51/45
52/46
53/47
58/50
59/51
60/52
61/53
60/52
60/52
61/53
62/54
57/51
58/52
59/53
60/54
59/50
60/51
61/52
62/53
212
264
314
364
WALL THICKNESS mm
CSR 280
/180/180
120/120/120
BOTH SIDES
2 x 16mm GYPROCK
FYRCHEK plasterboard.
FAR2357
WALL THICKNESS mm
FRL
Report/Opinion
SYSTEM
N
CSR 216
/60/60
30/30/30
60/60/60*
CAVITY WIDTH mm
WALL LININGS
CAVITY INFILL
(Refer to Section A)
SIDE ONE
1 x 13mm GYPROCK
FYRCHEK Plasterboard.
(*ACR15%)
SIDE TWO
FAR 2357
1 x 16mm GYPROCK
FYRCHEK Plasterboard.
300
(a) Nil
WALL THICKNESS mm
*ACR15%
250
(a) Nil
CSR 212
/120/120
60/60/60
90/90/90*
200
Rw / Rw+Ctr
(Refer to Section A)
CSR 275
/120/120
90/90/90
120/120/120*
148
CAVITY INFILL
55/50
50 GW Partition 11kg
WALL THICKNESS mm
201
B19
ACOUSTIC
OPINION
or
TEST
Test
ATF 1912
Test
ATF 19322
Opinion
RP 02267S
Discontinuous
Construction
FRL
Report/Opinion
SYSTEM
N
CSR 222
/120/120
WFRA
21241
WALL LININGS
WFRA
21241
(a) Nil
52/44
53/45
56/48
59/51
56/48
153
177
54/46
WALL THICKNESS mm
(a) Nil
53/45
1 x 13mm GYPROCK
plasterboard CD.
58/50
59/51
58/50
153
177
(a) Nil
53/45
53/45
WFRA
21241
1 x 13mm GYPROCK
SOUNDCHEK.
/120/90
58/50
STUD SIDE
58/50
1 x 6mm CeminSeal
Wallboard.
58/50
146
170
WALL THICKNESS mm
CSR 226
/120/90
WFRA
21241
B20
Rw / Rw+Ctr
1 x 13mm GYPROCK
plasterboard CD.
STUD SIDE
CSR 225
100
1 x 13mm GYPROCK
plasterboard CD.
/120/120
76
STUD SIDE
CSR 223
(a) Nil
54/46
55/47
1 x 13mm GYPROCK
plasterboard CD.
59/51
STUD SIDE
1 x 9mm CeminSeal
Wallboard.
60/52
59/51
149
173
ACOUSTIC
OPINION
or
TEST
Opinion
RP 02267S
Discontinuous
Construction
FRL
Report/Opinion
SYSTEM
N
CSR 230
/120/120
WFRA
21241
WFRA
21241
WFRA
21241
Rw / Rw+Ctr
60/50
60/50
1 x 13mm GYPROCK
plasterboard CD.
61/51
61/51
60/50
60/50
211
239
STUD SIDE
50 GW Partition 11kg
62/53
62/53
1 x 13mm GYPROCK
SOUNDCHEK.
62/53
62/53
61/52
62/53
211
239
50 GW Partition 11kg
60/50
60/50
61/51
61/51
60/50
1 x 13mm GYPROCK
SOUNDCHEK.
STUD SIDE
1 x 13mm GYPROCK
AQUACHEK.
92
50 GW Partition 11kg
CSR 235
64
1 x 13mm GYPROCK
plasterboard CD.
/120/120
STUD SIDE
CSR 231
/120/120
STUD DEPTH mm
WALL LININGS
211
239
B21
ACOUSTIC
OPINION
or
TEST
Opinion
RP 02267S
Discontinuous
Construction
20mm gap.
2 x 25mm GYPROCK Shaft Liner Panel in H-Studs at
600mm maximum centres.
20mm gap.
Cavity insulation as per system table.
Steel studs at 600mm maximum centres
Lining material as per system table fixed to studs - Side 2.
FRL
Report/Opinion
SYSTEM
N
CSR 240
/120/120
SIDE 1 AND 2
64
76
Rw / Rw+Ctr
(a) Nil
58/47
58/47
62/53
62/53
63/54
62/53
62/53
245
269
(a) Nil
59/48
60/49
SIDE 1 AND 2
64/55
65/56
1 x 13mm GYPROCK
SOUNDCHEK.
63/54
63/54
245
269
1 x 13mm GYPROCK
plasterboard CD.
WFRA
21241
STUD DEPTH mm
WALL LININGS
CSR 241
/120/120
WFRA
21241
CSR 243
/120/120
SIDE 1 AND 2
1 x 13mm GYPROCK
AQUACHEK.
WFRA
21241
(a) Nil
58/47
58/47
62/53
63/54
63/54
62/53
63/54
245
269
62/53
62/53
63/54
237
261
CSR 244
/60/60
SIDE 1 AND 2
SF 45743
1 x 9mm CeminSeal
Wallboard.
B22
Steel Frame Internal Wall Systems Party Wall 25mm Fire Barrier
SYSTEM SPECIFICATION
ACOUSTIC
OPINION
PKA-052
FRL
Report/Opinion
SYSTEM
N
STUD DEPTH mm
WALL LININGS
64
76
Rw / Rw+Ctr
CSR 100
(a) 75 GW Partition 14kg
60/48
61/49
60/60/60
BOTH SIDES
62/50
62/50
EWFA 45743
2 x 10mm GYPROCK
Plasterboard CD.
61/49
62/50
257
289
CSR 101
(a) 75 GW Partition 14kg
62/50
62/51
60/60/60
BOTH SIDES
63/52
63/52
EWFA 45743
2 x 13mm GYPROCK
Plasterboard CD.
63/51
63/52
269
301
CSR 102
(a) 75 GW Partition 14kg
60/48
61/49
60/60/60
BOTH SIDES
62/50
62/50
EWFA 45743
1 x 13mm GYPROCK
SOUNDCHEK.
61/49
62/50
243
275
CSR 103
60/60/60
EWFA 45743
BOTH SIDES
61/49
61/50
1 x 6mm CeminSeal
Wallboard.
62/50
62/51
63/51
63/52
249
281
1 x 10mm GYPROCK
AQUACHEK.
B23
Steel Frame Internal Wall Systems Party Wall 41mm Fire Barrier
SYSTEM SPECIFICATION
ACOUSTIC
OPINION
PKA-052
Discontinuous
Construction
SYSTEM
N
STUD DEPTH mm
WALL LININGS
64
76
92
Rw / Rw+Ctr
(Refer to Section A)
CSR 111
(a) 50 GW Partition 11kg
61/48
61/48
62/50
90/90/90
BOTH SIDES
63/50
63/50
64/52
EWFA 45743
1 x 13mm GYPROCK
Plasterboard CD.
62/48
62/48
63/50
235
259
291
61/48
61/48
62/50
63/50
63/50
64/52
64/51
64/51
65/53
228
252
284
CSR 113
SIDE ONE
1 x 6mm CeminSeal
Wallboard.
90/90/90
SIDE TWO
EWFA 45743
1 x 13mm GYPROCK
Plasterboard CD.
CSR 114
(a) 50 GW Partition 11kg
61/48
61/49
62/50
90/90/90
BOTH SIDES
63/50
63/51
64/52
EWFA 45743
1 x 6mm CeminSeal
Wallboard.
62/48
62/49
63/50
221
245
277
CSR 115
(a) 50 GW Partition 11kg
62/50
62/50
63/51
90/90/90
BOTH SIDES
63/51
63/51
64/52
EWFA 45743
1 x 13mm GYPROCK
AQUACHEK.
63/50
63/50
64/51
235
259
291
B24
ACOUSTIC
OPINION
PKA-054
Discontinuous
Construction
FRL
Report/Opinion
SYSTEM
N
WALL LININGS
CSR 290
BOTH SIDES
1 x 13mm GYPROCK
Plasterboard CD.
//
TRACK WIDTH mm
51
46/37
47/39
53/44
54/46
54/45
55/47
53/44
54/46
131
144
(a) Nil
47/39
48/40
54/46
55/47
55/47
56/48
54/46
55/47
131
144
WALL THICKNESS mm
CSR 291
BOTH SIDES
/60/60
1 x 13mm GYPROCK
FYRCHEK plasterboard.
FAR2039
WALL THICKNESS mm
CSR 292
BOTH SIDES
1 x 16mm GYPROCK
FYRCHEK plasterboard.
/90/90
FAR2039
1 x 10mm GYPROCK
plasterboard CD.
(a) Nil
51/43
53/45
58/50
60/52
59/51
61/53
58/50
60/52
157
170
WALL THICKNESS mm
SYSTEM SPECIFICATION
64
Rw / Rw+Ctr
ACOUSTIC
OPINION
PKA-054
Discontinuous
Construction
FRL
Report/Opinion
SYSTEM
N
WALL LININGS
CAVITY WIDTH mm
CAVITY INFILL (Refer to Section A)
84
96
Rw / Rw+Ctr
CSR 293
/90/90
FAR2039
BOTH SIDES
(a) Nil
50/42
51/43
1 x 16mm GYPROCK
FYRCHEK plasterboard.
57/49
58/50
57/49
58/50
163
175
1 x 10mm GYPROCK
plasterboard CD.
WALL THICKNESS mm
B25
ACOUSTIC
OPINION
PKA-054
Discontinuous
Construction
FRL
Report/Opinion
SYSTEM
N
TRACK WIDTH mm
WALL LININGS
/60/60
BOTH SIDES
FCO 2039
1 x 13mm GYPROCK
FYRCHEK plasterboard.
BOTH SIDES
/90/90
1 x 16mm GYPROCK
FYRCHEK plasterboard.
FCO 2039
1 x 10mm GYPROCK
plasterboard CD.
48/40
50/42
51/43
55/47^
57/49
58/50
58/50^
59/51
53/45^
55/47
56/48
154
177
190
(a) Nil
52/45
54/47
55/48
59/52^
61/54
62/55
62/55^
63/56
57/50^
59/52
60/53
180
203
216
(a) Nil
49/41
51/43
52/44
56/48^
58/50
59/51
59/51^
60/52
54/46^
56/48
57/49
160
183
196
WALL THICKNESS mm
CSR 297
/90/90
BOTH SIDES
FCO 2039
1 x 16mm GYPROCK
FYRCHEK plasterboard.
64
(a) Nil
WALL THICKNESS mm
CSR 295
51
Rw / Rw+Ctr
(Refer to Section A)
CSR 294
WALL THICKNESS mm
B26
28
CAVITY INFILL
ACOUSTIC
OPINION
PKA-054
Discontinuous
Construction
FRL
Report/Opinion
SYSTEM
N
WALL LININGS
CAVITY WIDTH mm
84
96
112
Rw / Rw+Ctr
CSR 296
/90/90
FCO 2039
BOTH SIDES
(a) Nil
52/44
53/46
54/47
1 x 16mm GYPROCK
FYRCHEK plasterboard.
60/52
61/54
62/55
59/51
60/53
61/54
186
198
214
1 x 10mm GYPROCK
plasterboard CD.
WALL THICKNESS mm
CSR 298
(a) Nil
48/40
49/41
50/42
/90/90
BOTH SIDES
56/48
57/49
58/50
FCO 2039
1 x 16mm GYPROCK
FYRCHEK plasterboard.
55/47
56/48
57/49
166
178
194
WALL THICKNESS mm
SYSTEM SPECIFICATION
ACOUSTIC
OPINION
FRL
Report/Opinion
SYSTEM
N
WALL LININGS
TRACK/PANEL
27
50
Rw / Rw+Ctr
CSR 284
BOTH SIDES
FRL
//
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
(a) Nil
WALL THICKNESS mm
49
71
55
77
CSR 285
FRL
//
BOTH SIDES
(a) Nil
1 x 13mm GYPROCK
Plasterboard CD.
WALL THICKNESS mm
B27
ACOUSTIC
OPINION
NOT
Deemed
Discontinuous
Construction
SYSTEM
N
CSR 060
STUD DEPTH mm
WALL LININGS
FAR2357
1 x 13mm GYPROCK
FYRCHEK plasterboard.
SIDE TWO
CSR 061
BOTH SIDES
2 x 13mm GYPROCK
FYRCHEK plasterboard.
*ACR10%
CAVITY INFILL
FAR2357
/180/180
and
120/120/120
FAR2357
BOTH SIDES
2 x 16mm GYPROCK
FYRCHEK plasterboard.
150
45/38
45/38
47/40
48/42
53/44
52/43
54/45
55/47
54/45
54/45
56/47
56/48
52/45
52/45
53/46
54/48
54/44
54/45
55/45
56/47
131
143
159
217
(a) Nil
48/42
49/43
49/43
51/45
56/48
56/48
56/48
58/50
57/49
58/50
58/50
59/51
55/49
56/50
55/49
57/51
57/48
58/49
57/48
59/50
144
156
172
230
(a) Nil
48/42
48/42
49/43
50/44
56/48
55/47
56/48
57/49
57/49
57/49
58/50
58/50
55/49
55/49
55/49
56/50
57/48
57/48
57/48
58/49
156
168
184
242
(e) 60
Soundscreen
1.6
(e) 60
Soundscreen
1.6
(e) 60
Soundscreen
1.6
B28
92
(a) Nil
CSR 062
76
Rw / Rw+Ctr
(Refer to Section A)
/90/90
and
30/30/30
/120/120
90/90/90
120/120/120*
64
ACOUSTIC
OPINION
PKA-201001
NOT
Deemed
Discontinuous
Construction
FRL
Report/Opinion
SYSTEM
N
WALL LININGS
Rw
CSR 945
120/120/120
FAR2357
77
BOTH SIDES
77
3 x 16mm GYPROCK
FYRCHEK plasterboard
77
CSR 946
SIDE ONE
3 x 16mm GYPROCK
FYRCHEK plasterboard
120/120/120
SIDE TWO
FAR2357
4 x 16mm GYPROCK
FYRCHEK plasterboard
471
79
79
79
487
CSR 947
120/120/120
FAR2357
81
BOTH SIDES
81
4 x 16mm GYPROCK
FYRCHEK plasterboard
81
503
B29
ACOUSTIC
OPINION
PKA-052
FRL
Report/Opinion
SYSTEM
N
WALL LININGS
CAVITY INFILL
(Refer to Section A)
Rw / Rw+Ctr
CSR 085
//
1 x 13mm GYPROCK CD
plasterboard.
(a) Nil
24/22
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
(a) Nil
25/22
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
(a) Nil
31/28
2 x 13mm GYPROCK
FYRCHEK plasterboard.
(a) Nil
33/30
2 x 16mm GYPROCK
FYRCHEK plasterboard.
(a) Nil
33/30
CSR 086
//
CSR 089
//
CSR 090
/30/30
and
30/30/30
FAR2357
/60/60
and
60/60/60
CSR 091
FAR2357
B30
ACOUSTIC
OPINION
PKA-052
FRL
Report/Opinion
Fire rated from
lined side only
SYSTEM
N
STUD DEPTH mm
WALL LININGS
CAVITY INFILL
(Refer to Section A)
ALL
Rw / Rw+Ctr
CSR 092
/90/90
and
90/90/90
3 x 13mm GYPROCK
FYRCHEK plasterboard.
(a) Nil
36/33
3 x 16mm GYPROCK
FYRCHEK plasterboard.
(a) Nil
36/33
FAR2357
Fire rated from
lined side only
/120/120
and
120/120/120
CSR 093
FAR2357
B31
ACOUSTIC
OPINION
PKA-052
FRL
Report/Opinion
SYSTEM
N
CSR 970
BRANZ
LOP 493
CSR 971
Test SI 1517
B32
38/31
42/35
43/34
47/38
49/40
42/35
46/39
48/38
80
118
(a) Nil
41/34
46/40
46/37
51/43
53/45
SIDE ONE
45/38
50/44
2 x 13mm GYPROCK
FYRCHEK plasterboard.
52/43
90
128
(a) Nil
41/34
46/40
46/37
51/43
53/45
SIDE ONE
45/38
50/44
2 x 16mm GYPROCK
FYRCHEK plasterboard.
52/43
96
134
BETWEEN STUDS
1 x 25mm GYPROCK
SHAFT LINER PANEL.
FAR3637
Rw / Rw+Ctr
1 x 16mm GYPROCK
FYRCHEK plasterboard.
/90/90
CAVITY INFILL
102
(a) Nil
BETWEEN STUDS
SIDE ONE
CSR 977
64
(Refer to Section A)
1 x 25mm GYPROCK
SHAFT LINER PANEL.
/60/60
/120/120
STUD DEPTH mm
WALL LININGS
BETWEEN STUDS
1 x 25mm GYPROCK
SHAFT LINER PANEL.
(e) 60
Soundscreen
1.6
WALL THICKNESS mm
WALL THICKNESS mm
WALL THICKNESS mm
ACOUSTIC
OPINION
PKA-052
FRL
Report/Opinion
SYSTEM
N
WALL LININGS
CAVITY INFILL
(Refer to Section A)
Rw
CSR 967S
/90/90
WFRA 21898
3 x 13mm GYPROCK
FYRCHEK plasterboard
(screw fixing).
(a) Nil
35
3 x 13mm GYPROCK
FYRCHEK plasterboard
(screw & adhesive fixing).
(a) Nil
35
3 x 16mm GYPROCK
FYRCHEK plasterboard
(screw fixing).
(a) Nil
36
3 x 16mm GYPROCK
FYRCHEK plasterboard
(screw & adhesive fixing).
(a) Nil
36
(a) Nil
37
CSR 967SA
/90/90
WFRA 21898
CSR 968S
/120/120
WFRA 21898
CSR 968SA
/120/120
WFRA 21898
CSR 969SA
1 x 16mm GYPROCK
FYRCHEK plasterboard.
/120/120
1 x 25mm GYPROCK
SHAFT LINER PANEL.
WFRA 21898
1 x 16mm GYPROCK
FYRCHEK plasterboard
(screw & adhesive fixing).
B33
ACOUSTIC
OPINION
PKA-052
FRL
Report/Opinion
SYSTEM
N
CSR 136
STUD SIZE mm
WALL LININGS
SHAFT SIDE
WALL SIDE
WFRA 21898
CSR 137
/90/90
/90/90
WFRA 21898
54/45
55/46
55/46
56/47
53/46
53/46
54/47
55/45
55/45
56/46
128
140
156
47/40
48/41
49/42
55/46
56/47
56/47
56/47
57/48
58/49
54/47
55/48
56/49
1.6
56/46
57/47
58/48
128
140
156
(a) Nil
46/39
47/40
49/42
54/45
55/46
56/47
55/46
56/47
58/49
53/46
54/47
56/49
55/45
56/46
58/48
128
140
156
(a) Nil
46/39
47/40
47/40
54/45
55/46
54/45
55/46
56/47
56/47
53/46
54/47
54/47
55/45
56/46
56/46
121
133
149
SHAFT SIDE
SHAFT SIDE
3 x 13mm GYPROCK
FYRCHEK plasterboard.
WALL SIDE
1 x 6mm CeminSeal
Wallboard.
B34
47/40
54/45
(a) Nil
1 x 13mm GYPROCK
AQUACHEK.
CSR 139
46/39
54/45
3 x 13mm GYPROCK
FYRCHEK plasterboard.
WALL SIDE
WFRA 21898
46/39
SHAFT SIDE
3 x 13mm GYPROCK
FYRCHEK plasterboard.
/90/90
(a) Nil
(e) 60
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
CSR 138
92
1 x 13mm GYPROCK
plasterboard CD.
WALL SIDE
WFRA 21898
76
Rw / Rw+Ctr
(Refer to Section A)
3 x 13mm GYPROCK
FYRCHEK plasterboard.
/90/90
64
CAVITY INFILL
Soundscreen
1.6
WALL THICKNESS mm
(e) 60
Soundscreen
WALL THICKNESS mm
(e) 60
Soundscreen
1.6
WALL THICKNESS mm
(e) 60
Soundscreen
1.6
WALL THICKNESS mm
ACOUSTIC
OPINION
PKA 052
FRL
Report/Opinion
SYSTEM
N
CSR 140
STUD SIZE mm
WALL LININGS
SHAFT SIDE
WALL SIDE
WFRA 21898
CSR 141
/120/120
/120/120
WFRA 21898
47/40
55/46
54/45
55/46
56/47
56/47
53/46
54/47
54/47
55/45
56/46
56/46
137
149
165
(a) Nil
47/40
49/42
49/42
55/46
57/48
56/47
56/47
58/49
58/49
54/47
56/49
56/49
1.6
56/46
58/48
58/48
137
149
165
(a) Nil
46/39
47/40
49/42
54/45
55/46
56/47
55/46
56/47
58/49
53/46
54/47
56/49
55/45
56/46
58/48
137
149
165
(a) Nil
46/39
47/40
49/42
54/45
55/46
56/47
55/46
56/47
58/49
53/46
54/47
56/49
1.6
55/45
56/46
58/48
130
142
158
SHAFT SIDE
1 x 13mm GYPROCK
AQUACHEK.
CSR 143
47/40
54/45
3 x 16mm GYPROCK
FYRCHEK plasterboard.
WALL SIDE
WFRA 21898
46/39
SHAFT SIDE
3 x 16mm GYPROCK
FYRCHEK plasterboard.
/120/120
(a) Nil
(e) 60
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
CSR 142
92
1 x 13mm GYPROCK
plasterboard CD.
WALL SIDE
WFRA 21898
76
Rw / Rw+Ctr
(Refer to Section A)
3 x 16mm GYPROCK
FYRCHEK plasterboard.
/120/120
64
CAVITY INFILL
SHAFT SIDE
3 x 16mm GYPROCK
FYRCHEK plasterboard.
WALL SIDE
1 x 6mm CeminSeal
Wallboard.
Soundscreen
1.6
WALL THICKNESS mm
(e) 60
Soundscreen
WALL THICKNESS mm
(e) 60
Soundscreen
1.6
WALL THICKNESS mm
(e) 60
Soundscreen
WALL THICKNESS mm
B35
ACOUSTIC
OPINION
or
TEST
RP 02267S
FRL
Report/Opinion
SYSTEM
N
WALL LININGS
CAVITY INFILL
Rw / Rw + Ctr
(Refer to Section A)
CSR 248
FACE SIDE
/90/30
(a) Nil
36/33
1 x 13mm GYPROCK
Plasterboard CD.
WFRA 21241
WALL THICKNESS mm
64
CSR 249
/120/90
WFRA 21241
FACE SIDE
(a) Nil
36/33
1 x 13mm GYPROCK
FYRCHEK.
WALL THICKNESS mm
B36
64
ACOUSTIC
OPINION
PKA-055
FRL
Report/Opinion
SYSTEM
N
WALL LININGS
MAXIMUM GIRT
SPACING (mm)
CAVITY INFILL
600
(a) Nil
33
900
(a) Nil
34
1200
(c) Nil
36
(Refer to Section A)
Rw
CSR 940
EXTERNAL SIDE
60/60/60
2 x 16mm GYPROCK
FYRCHEK MR
plasterboard
CSR 941
EXTERNAL SIDE
90/90/90
3 x 13mm GYPROCK
FYRCHEK MR
plasterboard
CSR 942
120/120/120
(from outside only)
FAR2357
EXTERNAL SIDE
3 x 16mm GYPROCK
FYRCHEK MR
plasterboard
B37
ACOUSTIC
OPINION
PKA-055
FRL
Report/Opinion
SYSTEM
N
WALL LININGS
MAXIMUM GIRT
SPACING (mm)
CAVITY INFILL
(Refer to Section A)
Rw
CSR 933
EXTERNAL SIDE
//
Nil
(a) Nil
35
600
(a) Nil
38
CSR 934
60/60/60
(from outside only)
FAR2357
B38
EXTERNAL SIDE
2 x 16mm GYPROCK
FYRCHEK MR
plasterboard
ACOUSTIC
OPINION
PKA-055
FRL
Report/Opinion
SYSTEM
N
WALL LININGS
STUD DEPTH mm
92
150
Rw / Rw + Ctr
EXTERNAL SIDE
(a) Nil
43/36
Nil
CSR 932
THERMAL
Rt(WIN)
Rt(SUM)
44/38
1.8
1.5
50/43
51/45
2.5
2.3
51/43
52/45
3.1
2.8
149
207
(a) Nil
43/30
43/32
1.3
1.2
50/37
51/39
2.7
2.4
51/37
52/39
3.2
2.9
168
226
INTERNAL SIDE
//
1 x 13 GYPROCK
Plasterboard CD.
CSR 935
EXTERNAL SIDE
1 x 16mm GYPROCK
FYRCHEK MR
plasterboard
/90/90
60/60/60
INTERNAL SIDE
FAR2357
1 x 16mm GYPROCK
FYRCHEK plasterboard
ACOUSTIC
OPINION
PKA-055
FRL
Report/Opinion
SYSTEM
N
WALL LININGS
GIRT DEPTH mm
CAVITY INFILL (Refer to Section A)
150
Rw / Rw + Ctr
CSR 166
EXTERNAL SIDE
//
(a) Nil
27/24
1 x 8mm Cemintel
RendaLine.
193
B39
ACOUSTIC
OPINION
PKA-055
FRL
Report/Opinion
SYSTEM
N
WALL LININGS
STUD DEPTH mm
CAVITY INFILL (Refer to Section A)
76
THERMAL
Rw / Rw+Ctr
Rt(WIN)
Rt(SUM)
(a) Nil
38/31
1.7
1.5
46/37
3.1
2.8
1 x 10mm GYPROCK
Plasterboard CD.
45/35
2.6
2.4
CSR 165
//
WALL THICKNESS mm
SYSTEM SPECIFICATION
129
ACOUSTIC
OPINION
PKA-055
FRL
Report/Opinion
SYSTEM
N
CSR 167
WALL LININGS
EXTERNAL SIDE
1 x 13mm GYPROCK
FYRCHEK MR
plasterboard.
60/60/60
(from outside only)
INTERNAL SIDE
FAR2357
STUD DEPTH mm
76
Rw
Rt(WIN)
Rt(SUM)
(a) Nil
40
1.2
1.1
46
2.6
2.4
47
2.7
2.5
1 x 10mm GYPROCK
Plasterboard CD.
CSR 168
60/60/60
FAR2357
EXTERNAL SIDE
1 x 13mm GYPROCK
FYRCHEK MR
plasterboard.
INTERNAL SIDE
1 x 16mm GYPROCK
FYRCHEK plasterboard.
B40
WALL THICKNESS mm
THERMAL
142
(a) Nil
42
1.2
1.1
48
2.6
2.4
49
2.7
2.5
WALL THICKNESS mm
148
ACOUSTIC
OPINION
PKA-055
FRL
Report/Opinion
SYSTEM
N
CSR 170
60/60/60
(from outside only)
FAR2357
WALL LININGS
STUD DEPTH mm
CAVITY INFILL (Refer to Section A)
60/60/60
FAR2357
THERMAL
Rw / Rw+Ctr
Rt(WIN)
Rt(SUM)
EXTERNAL SIDE
(a) Nil
40/32
1.8
1.5
As per system
specification
45/36
2.6
2.3
INTERNAL SIDE
45/35
3.1
2.8
1 x 10mm GYPROCK
Plasterboard CD.
CSR 171
76
WALL THICKNESS mm
129
EXTERNAL SIDE
(a) Nil
43/35
1.8
1.6
As per system
specification
47/38
2.6
2.4
INTERNAL SIDE
48/38
3.1
2.9
1 x 16mm GYPROCK
FYRCHEK plasterboard.
SYSTEM SPECIFICATION
WALL THICKNESS mm
135
ACOUSTIC
OPINION
PKA-055
FRL
Report/Opinion
SYSTEM
N
CSR 179
90/90/90
FAR2357
STUD DEPTH mm
76
Rw
Rt(WIN)
Rt(SUM)
EXTERNAL SIDE
(a) Nil
45
1.3
1.2
As per system
specification
51
2.7
2.5
52
3.2
2.9
WALL LININGS
2 x 13mm GYPROCK
FYRCHEK plasterboard.
CSR 178
90/90/90
FAR2357
151
EXTERNAL SIDE
As per system
specification
INTERNAL WALL SIDE
1 x 6mm CeminSeal
Wallboard (to stud).
1 x 16mm GYPROCK
FYRCHEK plasterboard.
WALL THICKNESS mm
THERMAL
(a) Nil
45
1.2
1.2
51
2.6
2.4
52
2.7
2.5
WALL THICKNESS mm
147
B41
ACOUSTIC
OPINION
PKA-055
Sarking.
Lining material to external side as per system table.
Steel studs at 600mm maximum centres.
Lining material to internal side as per system table.
NOTES:
Acoustic performance valid for studs of 0.80 BMT.
*ACR = Axial Capacity Reduction.
FRL
Report/Opinion
SYSTEM
N
CSR 118
WALL LININGS
EXTERNAL SIDE OF STUD
1 x 13mm GYPROCK
FYRCHEK MR
plasterboard.
30/30/30
(from outside only)
FAR2357
INTERNAL SIDE
1 x 10mm GYPROCK
Plasterboard CD.
CSR 121
60/60/60*
(from outside only)
*ACR 5%
FAR2357
INTERNAL SIDE
1 x 10mm GYPROCK
Plasterboard CD.
CSR 119
90/90/90
(from outside only)
FAR2357
INTERNAL SIDE
1 x 10mm GYPROCK
Plasterboard CD.
CSR 122
60/60/60
90/90/90*
*ACR 15%
INTERNAL SIDE
FAR2357
1 x 16mm GYPROCK
FYRCHEK plasterboard.
CSR 123
120/120/120
(from outside only)
INTERNAL SIDE
FAR2357
1 x 10mm GYPROCK
Plasterboard CD.
CSR 120
120/120/120
/180/180
FAR2357
B42
STUD DEPTH mm
CAVITY INFILL (Refer to Section A)
76
THERMAL
Rw
Rt(WIN)
Rt(SUM)
(a) Nil
33 37
1.0
1.0
39 43
2.4
2.2
40 44
2.9
2.7
36 40
1.0
1.0
39 43
2.4
2.2
40 44
3.0
2.7
37 41
1.1
1.0
43 47
2.4
2.2
44 48
2.9
2.7
38 42
1.1
1.0
41 45
2.5
2.3
42 46
3.0
2.8
Batts
1.5
Batts
1.5
Batts
1.5
129
132
142
138
(a) Nil
37 41
1.1
1.1
43 47
2.4
2.2
44 48
3.0
2.7
148
(a) Nil
42 46
1.3
1.2
48 52
2.6
2.4
49 53
3.1
2.8
140
Steel Frame External Wall Systems Texture Base Sheet For Houses
SYSTEM SPECIFICATION
ACOUSTIC
OPINION
PKA-052
FRL
Report/Opinion
SYSTEM
N
CSR 127
WALL LININGS
EXTERNAL SIDE OF STUD
1 x 13mm GYPROCK
FYRCHEK MR
plasterboard.
60/60/60
(from outside only)
INTERNAL SIDE
FAR2357
STUD DEPTH mm
60/60/60*
*ACR 15%
FAR2357
INTERNAL SIDE
(a) Nil
40/33
60/60/60
(from outside only)
INTERNAL SIDE
FAR2357
Rt(SUM)
42/35
0.5
0.5
46/37
48/39
1.9
1.8
47/37
49/39
2.4
2.2
107
123
41/34
42/35
0.5
0.5
47/38
48/39
1.9
1.8
48/38
49/39
2.5
2.3
113
129
(a) Nil
41/34
42/35
0.5
0.5
47/38
48/39
1.9
1.8
48/38
49/39
2.4
2.2
110
126
(a) Nil
42/35
44/37
0.6
0.5
48/39
50/41
2.0
1.8
49/39
51/41
2.5
2.3
116
132
WALL THICKNESS mm
(a) Nil
(b) 75 Gold Batts 1.5
(c) 75
60/60/60
90/90/90*
*ACR 15%
FAR2357
Soundscreen
2.0
WALL THICKNESS mm
1 x 10mm GYPROCK CD
plasterboard.
CSR 129
THERMAL
Rt(WIN)
1 x 16mm GYPROCK
FYRCHEK plasterboard.
CSR 126
92
Rw / Rw + Ctr
1 x 10mm GYPROCK
Plasterboard CD.
CSR 128
76
WALL THICKNESS mm
WALL THICKNESS mm
B43
ACOUSTIC
OPINION
PKA-055
FRL
Report/Opinion
SYSTEM
N
WALL LININGS
Rw / Rw + Ctr
THERMAL
Rt(WIN)
Rt(SUM)
CSR 937
(a) Nil
60/51
65/56
2.5
2.3
INTERNAL SIDE
1 x 13mm GYPROCK
Plasterboard CD.
//
WALL THICKNESS mm
229
ACOUSTIC
OPINION
TYPICAL LAYOUT
2010675.1/
2401A/R1/JH
FRL
Report/Opinion
SYSTEM
N
WALL LININGS
STUD DEPTH mm
70
90
THERMAL
Rw / Rw+Ctr
(a) Nil
46/40
Rt(WIN)
Rt(SUM)
46/40
0.9
0.9
53/44
53/45
2.8
2.6
177
197
HEBEL 1401
240/180/180
(from outside only)
FSV0356
INTERNAL SIDE
1 x 10mm GYPROCK
Plasterboard CD.
WALL THICKNESS mm
B44
ACOUSTIC
OPINION
PKA-055
FRL
Report/Opinion
SYSTEM
N
CSR 184
FRL
60/60/60
from outside only
refer to
Masonry
Manufacturer
FAR 2357
and refer to
Masonry
Manufacturer
CSR 186
FAR 2357
and refer to
Masonry
Manufacturer
Soundscreen
2.5
92
THERMAL
Rw / Rw+Ctr
Rt(WIN)
Rt(SUM)
52/44
0.5
0.5
59/51
2.1
2.0
59/50
3.2
2.9
252
(a) Nil
55/48
0.6
0.6
62/55
2.2
2.0
62/54
3.2
2.9
258
(a) Nil
55/48
0.6
0.6
62/55
2.2
2.0
62/54
3.3
3.0
58/51
0.7
0.7
65/58
2.2
2.1
65/57
3.3
3.0
2 x 13mm GYPROCK
FYRCHEK plasterboard.
CSR 187
FAR 2357
and refer to
Masonry
Manufacturer
(a) Nil
1 x 16mm GYPROCK
FYRCHEK plasterboard.
FRL
90/90/90
CSR 185
STUD DEPTH mm
FRL
60/60/60
FRL
120/120/120
WALL LININGS
(b) 75 Gold
2 x 16mm GYPROCK
FYRCHEK plasterboard.
Batts
1.5
268
274
B45
SYSTEM SPECIFICATION
6-20mm gap
SYSTEM
N
CSR Gyprock
Universal
Encasement Clips
PLASTERBOARD
LINING
CSR 192
30//
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
CSIRO
FCO 1494
Each layer of
GYPROCK
FYRCHEK
plasterboard fixed at
200mm maximum
centres to all
framing
CSR 193
60//
2 x 13mm GYPROCK
FYRCHEK
plasterboard.
CSIRO
FCO 1494
2 x 16mm GYPROCK
FYRCHEK
plasterboard.
CSIRO
FCO 1494
Apply External
Corner Bead and
set all corners
Rondo Track
fixed to column
at ends and
800mm max.
centres
CSR 195
90//
RHS/SHS
Steel Column
18mm
Each layer of
GYPROCK FYRCHEK
plasterboard fixed at
200mm maximum
centres to all tracks
CSR 196
120//
CSIRO
FCO 1494
3 x 13mm GYPROCK
FYRCHEK
plasterboard.
200mm max.
B46
EC08 Partition
EC08 Fire
EC08 Impact
B47
ACOUSTIC
OPINION
PKA-056
FRL
Report/Opinion
SYSTEM
N
STUD DEPTH mm
WALL LININGS
BOTH SIDES
1 x 13mm GYPROCK
ECO8 Partition.
SIDE ONE
1 x 6mm CeminSeal
Wallboard.
//
CSR EC110
//
CSR EC620
//
B48
90
102
118
176
WALL THICKNESS mm
70
95
111
169
(a) Nil
SIDE TWO
WALL THICKNESS mm
(a) Nil
103
128
144
202
(a) Nil
SIDE TWO
1 x 13mm GYPROCK
ECO8 Impact
SIDE ONE
1 x 13mm GYPROCK
Plasterboard CD.
//
77
WALL THICKNESS mm
CSR EC305
2 x 13mm GYPROCK
ECO8 Partition
2 x 13mm GYPROCK
ECO8 Partition
//
(a) Nil
BOTH SIDES
1 x 13mm GYPROCK
ECO8 Partition.
CSR EC115
150
1 x 13mm GYPROCK
ECO8 Partition
92
SIDE TWO
SIDE ONE
76
(a) Nil
WALL THICKNESS mm
CSR EC605
64
Rw / Rw+Ctr
(Refer to Section A)
CSR EC105
//
51
CAVITY INFILL
WALL THICKNESS mm
77
102
118
176
(a) Nil
SIDE TWO
1 x 13mm GYPROCK
ECO8 Impact
SIDE ONE
1 x 6mm CeminSeal
Wallboard.
WALL THICKNESS mm
70
95
111
169
ACOUSTIC
OPINION
PKA-056
FRL
Report/Opinion
SYSTEM
N
STUD DEPTH mm
WALL LININGS
BOTH SIDES
1 x 13mm GYPROCK
ECO8 Impact.
FAR 2357
&
EWFA 24040
- /60/60
BOTH SIDES
1 x 13mm GYPROCK
ECO8 Fire.
FAR 2357
&
BWA 23035
CSR EC615
- /60/60
FAR 2357
&
BWA 23035
1 x 13mm GYPROCK
ECO8 Fire.
CSR EC210
- /90/90
FAR 2357
&
BWA 23035
- /120/120
FAR 2357
&
BWA 23035
2 x 13mm GYPROCK
ECO8 Fire.
WALL THICKNESS mm
176
77
102
118
176
83
108
124
182
(a) Nil
WALL THICKNESS mm
90
115
131
189
(a) Nil
103
128
144
202
(a) Nil
118
BOTH SIDES
102
WALL THICKNESS mm
- /120/120
90
CSR EC215
77
(a) Nil
SIDE TWO
2 x 13mm GYPROCK
ECO8 Impact.
FAR 2357
&
EWFA 24040
2 x 13mm GYPROCK
ECO8 Fire.
BOTH SIDES
CSR EC315
SIDE TWO
1 x 13mm GYPROCK
ECO8 Fire.
(a) Nil
1 x 6mm CeminSeal
Wallboard.
SIDE ONE
150
1 x 13mm GYPROCK
ECO8 Fire.
92
WALL THICKNESS mm
SIDE ONE
76
(a) Nil
WALL THICKNESS mm
CSR EC205
64
Rw / Rw+Ctr
(Refer to Section A)
CSR EC310
- /60/60
51
CAVITY INFILL
103
128
144
202
B49
ACOUSTIC
OPINION
PKA-056
FRL
Report/Opinion
SYSTEM
N
CAVITY WIDTH mm
WALL LININGS
FAR 2357
&
BWA 23035
39/32
41/34
44/38
47/38
49/40
51/43
BOTH SIDES
48/39
50/41
52/44
1 x 13mm GYPROCK
ECO8 Fire
46/39
48/41
50/44
48/38
50/40
52/43
102
118
176
(a) Nil
41/34
42/35
45/39
49/40
50/41
52/44
BOTH SIDES
50/41
51/42
53/45
1 x 13mm GYPROCK
ECO8 Impact
48/41
49/42
51/45
1.6
50/40
51/41
53/44
102
118
176
CSR EC320
FAR 2357
&
EWFA 24040
(e) 60
Soundscreen
WALL THICKNESS mm
B50
150
(a) Nil
WALL THICKNESS mm
- /60/60
92
Rw / Rw+Ctr
(Refer to Section A)
CSR EC220
- /60/60
76
CAVITY INFILL
ACOUSTIC
OPINION
PKA-056
FRL
Report/Opinion
SYSTEM
N
CAVITY WIDTH mm
WALL LININGS
BOTH SIDES
2 x 13mm GYPROCK
ECO8 Impact.
FAR 2357
&
EWFA 24040
CAVITY INFILL
CSR EC225
BOTH SIDES
FAR 2357
&
BWA 23035
2 x 13mm GYPROCK
ECO8 Fire.
250
300
Rw / Rw+Ctr
(a) Nil
51/45
53/47
54/48
54/48
59/51
61/53
62/54
62/54
61/53
62/54
63/55
63/55
58/52
60/54
61/55
61/55
60/51
62/53
63/54
63/54
200
252
302
352
(a) Nil
50/44
51/45
52/46
53/47
58/50
59/51
60/52
61/53
60/52
60/52
61/53
62/54
57/51
58/52
59/53
60/54
59/50
60/51
61/52
62/53
200
252
302
352
(e) 60
Soundscreen
1.6
WALL THICKNESS mm
/120/120
200
(Refer to Section A)
CSR EC325
/120/120
148
WALL THICKNESS mm
ACOUSTIC
OPINION
PKA-054
Discontinuous
Construction
FRL
Report/Opinion
SYSTEM
N
TRACK WIDTH mm
WALL LININGS
FAR 2039
&
BWA 23035
BOTH SIDES
1 x 13mm GYPROCK
ECO8 Fire.
64
(a) Nil
48/40
50/42
51/43
55/47^
57/49
58/50
58/50^
59/51
53/45^
55/47
56/48
WALL THICKNESS mm
51
Rw / Rw+Ctr
(Refer to Section A)
CSR EC230
- /60/60
28
CAVITY INFILL
154
177
190
B51
ACOUSTIC
OPINION
PKA-056
FRL
Report/Opinion
SYSTEM
N
WALL LININGS
CAVITY INFILL
(Refer to Section A)
Rw
(a) Nil
35
CSR EC031
- /90/90
FC0 1786
&
BWA 23035
B52
LINING
3 x 13mm GYPROCK
ECO8 Fire.
For additional information, refer to GYP544, Gyprock Steel Frame Wall Systems Installation Guide.
NON-FIRE RATED
Fixing Specifications
Screw
along sheet
centreline
at every
second
stud
200mm
min.
300mm
max.
Screws
Adhesive
Refer to Section A
Location
Field
Sheet
Width
900mm
1200mm
1350mm
Adhesive Daubs at
300mm max. centres
and 200mm min.
from fastener points
3 daubs
4 daubs
5 daubs
Screw at every
second stud along
sheet centreline
Recessed
Edges
Butt joints
Screws at 200mm
centres
Corners &
Openings
Screws at 300mm
max. centres
SUITABLE FOR:
200mm
max.
300mm
max.
300mm
max.
200mm
min.
FIG B3: FASTENER FIXING SINGLE LAYER HORIZONTAL SHEETING NON-TILED AREAS
For additional information, refer to GYP544, Gyprock Steel Frame Wall Systems Installation Guide.
NON-FIRE RATED
Fixing Specifications
For Level 4 finish, form butt
joints between framing
400mm
max.
300mm
max.
Screws
Refer to Section A
Location
Field
Screws at 400mm
max. centres
Sheet
Width
900mm
1200mm
1350mm
4 Screws
4 Screws
5 Screws
Recessed
Edges
Butt joints
Screws at 200mm
max. centres
Corners &
Openings
Screws at 300mm
max. centres
SUITABLE FOR:
200mm
max.
B53
For additional information, refer to GYP544, Gyprock Steel Frame Wall Systems Installation Guide.
NON-FIRE RATED
Fixing Specifications
Screws
Adhesive
Refer to Section A
Location
Field
Adhesive Daubs at
300mm max. centres
and 200mm min.
from fastener points
Screw at top and
bottom and 1200mm
max. cts
Recessed
Edges
Corners &
Openings
Screws at
300mm max. centres
300mm
max.
400mm
max.
300mm
max.
200mm
min.
Screw at
1200mm
max.
vertical
centres
SUITABLE FOR:
300mm
max.
200mm
min.
Noggings may not be permitted
in staggered stud systems
For additional information, refer to GYP544, Gyprock Steel Frame Wall Systems Installation Guide.
NON-FIRE RATED
Fixing Specifications
200mm
max.
300mm
max.
400mm
max.
CSR Bradford Acoustic
Insulation if required
400mm
max.
200mm
min.
Screw at
1200mm
max.
vertical
centres
Screws
Adhesive
Refer to Section A
1st Layer
Recessed
Edges &
Field
2nd Layer
Field
Adhesive Daubs at
300mm max. centres
and 200mm min.
from fastener points.
Screw at top and
bottom and 1200mm
max.cts
Recessed
Edges
Corners &
Openings
Screws at 300mm
max. centres
SUITABLE FOR:
300mm
max.
400mm
max.
B54
FIG B6: INSTALLATION DETAIL FOR INTERNAL WALL SYSTEMS CEMINSEAL WALLBOARD NON-TILED AREAS
HORIZONTAL SHEETING ADHESIVE/FASTENER FIXING
200mm
max.
NON-FIRE RATED
Fixing Specifications
Screws
Adhesive
Refer to Section A
Location
Field
Sheet
Width
900mm
1200mm
1350mm
Adhesive Daubs at
230mm max. centres
and 200mm min.
from fastener points
3 daubs
4 daubs
5 daubs
Screw through
temporary block
at every second
stud along sheet
centreline
Recessed
Edges
Butt joints
Screws at 200mm
centres
Corners &
Openings
Screws at 200mm
max. centres
Daubs of GYPROCK
Acrylic Stud Adhesive
200mm
max.
230mm
max.
SUITABLE FOR:
230mm
max.
200mm
min.
FIG B7: INSTALLATION DETAIL FOR INTERNAL WALL SYSTEMS CEMINSEAL WALLBOARD NON-TILED AREAS
HORIZONTAL SHEETING FASTENER FIXING
200mm
max.
300mm
max.
Screws
Refer to Section A
Location
Field
Screws at 300mm
max. centres
Sheet
Width
900mm
1200mm
1350mm
4 Screws
5 Screws
6 Screws
Recessed
Edges
Butt joints
Screws at 200mm
max. centres
Corners &
Openings
Screws at 300mm
max. centres
SUITABLE FOR:
200mm
max.
B55
FIG B8: INSTALLATION DETAIL FOR INTERNAL WALL SYSTEMS SINGLE LAYER VERTICAL SHEETING
For additional information, refer to GYP544, Gyprock Steel Frame Wall Systems Installation Guide.
FIRE RATED
200mm max.
Fixing Specifications
Screws
300mm
max.
600mm
min.
Refer to Section A
Location
Field
Screws at 300mm
max. centres
Recessed
Edges
Screws at
300mm max. centres
Butt
Joints
Screws at
200mm max. centres
Corners &
Openings
Screws at
300mm max. centres
SUITABLE FOR:
300mm
max.
300mm
max.
Refer to perimeter
details
FIG B9: INSTALLATION DETAIL FOR INTERNAL WALL SYSTEMS SINGLE LAYER HORIZONTAL SHEETING
For additional information, refer to GYP544, Gyprock Steel Frame Wall Systems Installation Guide.
FIRE RATED
Fixing Specifications
Screws
300mm
max.
300mm
max.
Recessed joints to be
offset a minimum 300mm
in opposing sides when not
backed by nogging
Refer to Section A
Location
Field
Screws at 300mm
max. centres
Recessed
Edges
Screw at
each stud
Butt
Joints
Screws at
200mm max. centres
Corners &
Openings
Screws at
300mm max. centres
SUITABLE FOR:
200mm
max.
200mm
max.
Refer to perimeter
details
B56
FIG B10: INSTALLATION DETAIL FOR INTERNAL WALL SYSTEMS TWO LAYER VERTICAL SHEETING
For additional information, refer to GYP544, Gyprock Steel Frame Wall Systems Installation Guide.
FIRE RATED
Fixing Specifications
300mm
max.
CSR Bradford Acoustic
Insulation if required
600mm
max.
200mm max.
laminating screws
Screws
Refer to Section A
1st Layer
Recessed
Edges
& Field
Screws at 600mm
max. centres
2nd Layer
Field
Screws at 300mm
max. centres
Recessed
Edges
Screws at
300mm max. centres
Butt
Joints
Screws at
200mm max. centres
Corners &
Openings
Screws at
300mm max. centres
SUITABLE FOR:
200mm
max.
300mm
max.
300mm
max.
Refer to perimeter
details
Noggings may not be permitted
in staggered stud systems
FIG B11: INSTALLATION DETAIL FOR INTERNAL WALL SYSTEMS TWO LAYER VERTICAL+HORIZONTAL SHEETING
For additional information, refer to GYP544, Gyprock Steel Frame Wall Systems Installation Guide.
FIRE RATED
Fixing Specifications
200mm
max.
300mm
max.
300mm
max.
600mm
max.
600mm
max.
Refer to Section A
1st Layer
Recessed
Edges
& Field
Screws at 600mm
max. centres
2nd Layer
Field
Screws at 300mm
max. centres
Recessed
Edges
Screw at
each stud
Butt
Joints
Screws at
200mm max. centres
Corners &
Openings
Screws at
300mm max. centres
SUITABLE FOR:
Refer to perimeter
details
Screws
Where butt
joints are
formed off
studs, laminate
to first layer
with laminating
screws at
200mm max.
B57
FIG B12: INSTALLATION DETAIL FOR INTERNAL WALL SYSTEMS TWO LAYER HORIZONTAL SHEETING
For additional information, refer to GYP544, Gyprock Steel Frame Wall Systems Installation Guide.
Stagger fasteners
at butt joints
FIRE RATED
Fixing Specifications
300mm
max.
600mm
max.
Two layers of GYPROCK
FYRCHEK plasterboard
to each side of wall in
accordance with system
specifications
Refer to perimeter
details
B58
Screws
Refer to Section A
1st Layer
Recessed
Edges &
Field
Screws at 600mm
max. centres
2nd Layer
Field
Screws at 300mm
max. centres
Recessed
Edges
Screw at
each stud
Butt
Joints
Screws at
200mm max. centres
Corners &
Openings
Screws at
300mm max. centres
SUITABLE FOR:
Where butt
joints are
formed off
studs,
laminate to
first layer
with
laminating
screws at
200mm
max.
Noggings may not be permitted
in staggered stud systems
For additional information, refer to GYP544, Gyprock Steel Frame Wall Systems Installation Guide.
FIRE RATED
Fixing Specifications for
Vertical Sheeting (shown)
600mm
300mm
600mm
300mm
Screws
Refer to Section A
1st Layer
Recessed
Edges,
Field,
Corners &
Openings
Screws at 600mm
max. centres on
studs
2nd Layer
Recessed
Edges
Field
Screws at 300mm
max. centres on
studs
Butt Joints
Laminating Screws at
200mm max. centres
Corners &
Openings
Screws at 300mm
max. centres
3rd Layer
Recessed
Edges,
Field, Butt
Joints
Corners &
Openings
Laminating screws
at 400x400mm max.
grid
FIRE RATED
400mm
400mm
Refer to perimeter
details
400mm
Refer to Section A
1st Layer
Recessed
Edges,
Field,
Butt Joints,
Corners &
Openings
Screws at 600mm
max. centres on
studs
2nd Layer
Recessed
Edges
Screws at 600mm
max. centres on
studs
Field
Screws at 300mm
max. centres on
studs
Corners &
Openings
Screws at 300mm
max. centres
Butt Joints
Screws at 200mm
max. centres on
studs
3rd Layer
Recessed
Edges,
Field, Butt
Joints
Corners &
Openings
Laminating screws
at 400x400mm max.
grid
SUITABLE FOR:
B59
FIG B14: INSTALLATION DETAIL FOR STEEL FRAME EXTERNAL WALL SYSTEM
TWO OR THREE LAYER VERTICAL SHEETING
For additional information, refer to GYP544, Gyprock Steel Frame Wall Systems Installation Guide.
200mm
400mm
200mm
Refer to
system table
for girt spacing
200mm
400mm
200mm
FIRE RATED
Fixing Specifications for
Vertical Sheeting (shown)
Screws
B60
SUITABLE FOR:
Refer to Section A
1st Layer
Field &
Butt Joints
Screws at 200mm
max. centres to all
girts
Recessed
Edges &
Butt Joints
Laminating Screws at
200mm max. centres
Field
Laminating Screws at
400 x 400mm max.
grid
Lost
studs
35 x 35 x 0.8mm
angle screw fixed at
400mm centres to
each stud
First layer
600mm
Nogging as required
600mm
Screws
Refer to Section A
1st Layer
Recessed
Edges,
Field,
Corners &
Openings
Screws at 600mm
max. centres on
studs
2nd Layer
Recessed
Edges
Field
Screws at 300mm
max. centres on
studs
Butt Joints
Laminating Screws at
200mm max. centres
Corners &
Openings
Screws at 300mm
max. centres
3rd Layer
Recessed
Edges,
Field, Butt
Joints
Corners &
Openings
Laminating screws
at 400x400mm max.
grid
300mm
FIRE RATED
Fixing Specifications for
Horizontal Sheeting
400mm
Refer to
perimeter
details
400mm
400mm
SUITABLE FOR:
Set outer
layer joints
from
accessible
side
Screws
Refer to Section A
1st Layer
Recessed
Edges,
Field,
Butt Joints,
Corners &
Openings
Screws at 600mm
max. centres on
studs
2nd Layer
Recessed
Edges
Screws at 600mm
max. centres on
studs
Field
Screws at 300mm
max. centres on
studs
Corners &
Openings
Screws at 300mm
max. centres
Butt Joints
Screws at 200mm
max. centres on
studs
3rd Layer
Recessed
Edges,
Field, Butt
Joints
Corners &
Openings
Laminating screws
at 400x400mm max.
grid
Alternative stud
type for in-line
stud framing
B61
FIRE RATED
Fixing Specifications for
Vertical Sheeting (shown)
J Track
C-H Studs
300mm
max.
25mm GYPROCK
Shaft Liner Panels
600mm
max.
300mm
max.
Screws
Refer to Section A
1st Layer
Recessed
Edges, &
Field
Screws at 600mm
max. centres on
studs
2nd Layer
Field
Screws at 300mm
max. centres
Recessed
Edges
Screws at
300mm max. centres
Butt
Joints
Screws at
200mm max. centres
Corners &
Openings
Screws at
300mm max. centres
IMPORTANT
300mm
max.
1st layer of
GYPROCK FYRCHECK
plasterboard
600mm
max.
FIRE RATED
75mm
IBS Backing
Rod at head
of 1st layer
Steel Angle
internal
framing
400mm
max.
75mm
600mm max.
400mm
max.
Apply adhesive*
and screw fix
2nd layer to
vertical steel
angles with
25/45mm
Gyprock screws.
Fix body with
laminating
screws at
600mm max.
horizontal x
400mm max.
vertical centres
Apply adhesive*
and screw fix
body of 3rd
layer with
laminating
screws only at
600mm max.
horizontal x
400mm max.
vertical centres
B62
SecurityWall
Track 27
FIRE RATED
300mm
max.
Gyprock
SecurityWall
Panel 27
1x 13mm
GYPROCK
FYRCHEK
plasterboard
Refer to Section A
1st Layer
Recessed
Edges, &
Field
Screws at 600mm
max. vertical centres
x 300mm max.
horizontal centres
Butt
Joints
Screws at
200mm max. centres
Corners &
Openings
Screws at
300mm max. centres
600mm
max.
Cavity
Insulation
Blanket
Base Track
300mm
max.
FIRE RATED
Security Wall
Track 27
Screws
Adhesive
Refer to Section A
1st Layer
Recessed
Edges, &
Field
Screws at 600mm
max. vertical centres
to all stud profiles
OR
Screws at 600mm
max. vertical centres
and 300mm max.
horizontal centres to
steel sheeting
200mm
min.
2nd Layer
Recessed
Edges
Screws at corners
and 600mm max. cts
300mm
max.
Field
Rows of Adhesive
Daubs at 600mm
max. horizontal cts x
300mm max. vertical
cts and 200mm min.
from fastener points
Screw along
centreline at 1200mm
max. cts
Butt
Joints
Screws at
200mm max. centres
Corners &
Openings
Screws at
300mm max. centres
300mm
max.
Gyprock
SecurityWall
Panel 27
200mm
max.
1x 10mm
GYPROCK
plasterboard CD
1x 16mm
GYPROCK
FYRCHEK
plasterboard
600mm
max.
Cavity
Insulation
Blanket
Base Track
300mm
max.
600mm
max.
B63
FIRE RATED
Security Wall
Track 50
1st Layer
Gyprock
SecurityWall
Panel 50
216mm
typical.
1x 13mm
GYPROCK
FYRCHEK
plasterboard
Screws
Butt
Joints
Screws at
216mm max. centres
Corners &
Openings
Screws at
300mm max. centres
600mm
max.
Cavity
Insulation
Blanket
300mm
max.
Base Track
FIRE RATED
Security Wall
Track 50
Gyprock
SecurityWall
Panel 50
1x 10mm
GYPROCK
plasterboard CD
1x 16mm
GYPROCK
FYRCHEK
plasterboard
200mm min.
600mm
max.
300mm max.
600mm
max.
433mm
typical
B64
Refer to Section A
1st Layer
Recessed
Edges
& Field
Screws at 600mm
max. vertical centres
to all stud profiles
OR
Screws at 600mm
max. vertical centres
x 300mm max.
horizontal centres to
all steel ribs
2nd Layer
Recessed
Edges
Screws at 450mm
max. cts
Field
Rows of Adhesive
Daubs at 600mm
max. horizontal cts x
300mm max. vertical
cts and 200mm min.
from fastener points
Screw along
centreline at 1300mm
max.cts
Butt
Joints
Screws at
200mm max. centres
Corners &
Openings
Screws at
300mm max. centres
216mm
typical
Cavity
Insulation
Batts
Base Angles
Screws
Adhesive
300mm
max.
433mm
typical
Screw along sheet
centreline at
1200mm max. cts
400mm
max. ctrs
450mm
max. ctrs
400mm
max. ctrs
450mm
max. ctrs
Butt Joints
in 3rd/4th
layers offset
600mm min.
Stagger joints
300mm min.
400mm
max. ctrs
Stagger joints
300mm min.
450mm
max. ctrs
FIRE RATED
Fixing Specifications
Screws
SUITABLE FOR:
Refer to Section A
1st Layer
At all studs
Screws at 400mm
max. centres
Recessed
Edges,
Field &
Butt Joints
Laminating screws at
450mm max.
horizontal centres
and 400mm max.
vertical centres
B65
Notes
B66
Section C
Contents
Timber Stud Height Tables
C2
Introduction
C3
Design Considerations
C3 C4
Installation
C5
Components
C5
C6 C9
Double Stud
C10 C12
Party Wall
C13 C14
Staggered Stud
C15 C17
Resilient Mount
C18 C19
C20 C21
C22 C23
C24
Hebel Powerpanel
C25
Masonry
C26 C27
Rendaline
C28 C29
Commercial ExpressWall
C30
C31
C32 C37
C1
Timber Grade
and Sheeting
Configuration
600mm cts.
450mm
cts.
70
F5
35
F8
45
35
F11
45
35
MGP 10
45
35
45
MGP 12
MGP 15
35
45
35
45
3.5
3.9
3.8
4.1
3.1
3.2
3.3
3.3
3.6
3.0
3.6
90
3.7
4.0
4.1
4.4
4.3
4.7
4.2
4.6
4.6
5.0
4.9
5.3
120
5.0
5.4
5.5
5.9
5.7
6.0
5.6
6.0
6.0
6.0
6.0
6.0
70
3.2
3.5
3.5
3.8
3.7
4.0
3.6
3.9
3.9
4.3
4.1
4.5
90
4.1
4.5
4.5
4.9
4.7
5.1
4.6
5.1
5.0
5.5
5.3
5.8
120
5.5
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
70
2.7
2.9
2.9
3.2
3.1
3.3
3.0
3.3
3.3
3.6
3.5
3.8
90
3.4
3.7
3.8
4.1
4.0
4.3
3.9
4.2
4.2
4.6
4.5
4.9
120
4.6
5.0
5.0
5.5
5.3
5.8
5.2
5.7
5.6
6.0
6.0
6.0
600mm cts.
300mm 300mm
cts.
cts.
Timber Grade
and Sheeting
Configuration
600mm cts.
450mm
cts.
F5
35
F8
45
35
F11
45
35
MGP 10
45
35
45
MGP 12
35
MGP 15
45
35
45
70
3.1
3.4
3.4
3.7
3.6
3.9
3.5
3.8
3.8
4.2
4.1
4.4
90
4.0
4.4
4.4
4.8
4.6
4.8
4.5
5.0
4.9
5.4
5.2
5.7
120
5.4
5.8
5.9
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
70
3.4
3.7
3.8
4.1
3.9
4.3
3.9
4.2
4.2
4.6
4.5
4.9
90
4.4
4.8
4.9
5.3
5.1
5.5
5.0
5.5
5.4
5.9
5.8
6.0
120
5.9
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
70
2.9
3.1
3.2
3.3
3.6
3.9
3.0
3.6
3.5
3.9
3.8
4.1
90
3.7
4.0
4.1
4.4
4.3
4.7
4.2
4.6
4.6
5.0
4.9
5.3
120
5.0
5.4
5.5
5.9
5.7
6.0
5.6
6.0
6.0
6.0
6.0
6.0
600mm cts.
300mm 300mm
cts.
cts.
C2
Introduction
CSR Gyprock & Cemintel timber frame wall systems are
assemblies constructed from timber components with one
or more layers of Gyprock plasterboard and/or Cemintel
linings fixed to one or both sides.
A wide range of systems is available including fire rated walls,
internal and external walls, and for loadbearing applications.
Timber frame wall systems are typically used in multiresidential applications.
Design
Considerations
structural design
All walls must be designed for the applied loads. Guidance
is given for the selection of studs in non-loadbearing internal
walls only. For loadbearing walls and walls subject to wind
pressures, walls shall be designed to the appropriate
Australian Standards or construction manuals.
Non-Loadbearing Walls
Maximum wall height and the required stud size may be
selected from Table C1 or C2 appropriate for the selected
system. These walls are designed for lateral loads only, using
the composite action of the frame and sheeting.
Non-loadbearing walls in this manual have been designed
as follows for a minimum design pressure of 0.25kPa and a
maximum deflection of (height 240) or 30mm maximum.
(Based on BCA Specification C1.8, 3.4 (b)).
Wall plates must be fixed to floors and ceilings at 600mm
maximum centres. Each plate fixing is required to withstand
a shear load of 0.75kN for a UDL of 0.25kPa
Tall multi-residential buildings often have exterior operable
doors and windows, resulting in internal walls being subject
to wind pressure. In these cases, walls must be designed
for the appropriate loads.
Loadbearing Walls
Walls designed as loadbearing, with studs at 600mm
maximum centres and lined with GYPROCK FYRCHEK,
meet the requirements of BCA Specification C1.8 Clause
3.4 Walls generally.
The building designer must ensure loadbearing walls have
been designed:
To resist all applied loads.
To be in accordance with AS1720.1 or AS1684.
Assuming no contribution to axial strength is required of
the wall linings.
To meet the stated Fire Resistance Level (FRL), the axial load
capacity of some wall systems is reduced. This is a result
of loss of stud section from charring during a fire test. The
systems are noted with an Axial Capacity Reduction (ACR)
Group number. In these systems, the designer must increase
the applied loads to compensate for the axial capacity
reduction percentage, as shown in Table C3.
TABLE C3: AxiAL CAPACiTY REduCTioN (%) duE To
ThE EFFECT oF TimBER ChAR
Timber Size
Group 1
Group 2
Group 3
90x45
0%
0%
25%
90x35
0%
10%
30%
70x45
3%
25%
40%
70x35
8%
35%
45%
Fire Resistance
The timber frame wall systems in this manual are suitable
for the stated FRL when designed in accordance with the
structural considerations above. Wall system ratings apply
in either direction unless noted otherwise.
The fire design of timber framing is based on the principle that
a particular level of char is acceptable without compromising
the performance of the wall. CSR has carried out testing to
verify the char limit, and where it is exceeded, the allowable
axial capacity of the stud is reduced to account for the loss
of section.
To protect structural timber and steel beams and columns
within a wall, the FRL of the wall system must be at least
equivalent to that required by the structural member. For
example, a wall system with FRL 90/90/90 provides FRL
90// for a steel column within the wall.
C3
Acoustic Performance
C4
Installation
Framing
For detailed information on wall junctions, intersections,
frame attachments and penetrations, refer to Section Z of
this guide and Woods & Forests publication, Timber Framed
Construction for Mult-Residential Buildings.
Walls curved in plan may be built with timber stud frames.
Table for stud centres and plasterboard thickness for various
curvatures can be found in CSR Gyprock Residential
Installation, Guide NGYP547.
Gyprock Party Wall systems have additional installation
requirements. Refer to brochure NGYP513 Gyprock Party
Wall Systems.
External Walls
Gyprock timber frame external wall systems rely on a
range of cladding systems to provide weather resistance.
There is a range of effectiveness of these systems, and
CSR Gyprock recommends the cladding be installed with
a drained cavity. Cavity systems allow drainage and drying
of any water that penetrates, and are known to have good
long-term performance.
Sarking is also recommended to provide additional weather
protection to framing and lining.
External walls require specific design for condensation
control and energy efficiency, depending on the climate and
internal environment. Contact CSR Bradford for information
on thermal insulation systems and products.
Components
Control Joints
Framing
C5
ACousTiC
oPiNioN
PKA-051
FRL
Report/Opinion
sYsTEm
N
sTud dEPTh mm
WALL LiNiNgs
(a) Nil
Both SideS
1 x 10mm GYPROCK
Plasterboard CD.
Both SideS
//
1 x 13mm GYPROCK
Plasterboard CD.
Side one
1 x 13mm GYPROCK
Plasterboard CD.
//
Side two
1 x 13mm GYPROCK
AQUACHEK plasterboard.
CsR 315
Both SideS
//
2 x 10mm GYPROCK
Plasterboard CD.
33/26
35/28
34/25
36/27
37/28
39/30
2.0
35/25
37/27
38/28
40/30
32/25
34/27
34/27
36/29
90
110
140
160
(a) Nil
33/26
34/27
36/29
37/30
37/28
38/29
40/31
41/32
38/28
39/29
41/31
42/32
35/28
36/29
37/30
38/31
96
116
146
166
(a) Nil
34/27
35/28
37/30
38/31
38/29
39/30
41/32
42/33
39/29
40/30
42/32
43/33
36/29
37/30
38/31
39/32
96
116
146
166
(a) Nil
38/31
39/32
41/35
42/36
42/33
43/34
45/37
46/38
43/33
44/34
46/37
47/38
40/33
41/34
42/36
43/37
110
130
160
180
(a) Nil
40/33
42/36
43/37
44/38
44/35
46/38
47/39
48/40
45/35
47/38
48/39
49/40
42/35
44/38
44/38
45/39
122
142
172
192
Soundscreen
WALL THICKNESS mm
WALL THICKNESS mm
CsR 320
Both SideS
//
2 x 13mm GYPROCK
Plasterboard CD.
WALL THICKNESS mm
CsR 322
//
C6
140
32/25
WALL THICKNESS mm
CsR 311
120
30/23
WALL THICKNESS mm
CsR 310
90
Rw / Rw+Ctr
(Refer to Section A)
CsR 305
//
70
CAViTY iNFiLL
Side one
(a) Nil
34/27
35/28
37/30
38/31
1 x 13mm GYPROCK
Plasterboard CD.
38/29
39/30
41/32
42/33
Side two
39/29
40/30
42/32
43/33
1 x 13mm GYPROCK
IMPACTCHEK
plasterboard.
36/29
37/30
38/31
39/32
96
116
146
166
WALL THICKNESS mm
ACousTiC
oPiNioN
PKA-051
FRL
Report/Opinion
sYsTEm
N
sTud dEPTh mm
WALL LiNiNgs
(a) Nil
Both SideS
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
//
37/30
38/31
39/32
39/30
41/32
42/33
43/34
2.0
40/30
42/32
43/33
44/34
37/30
39/32
39/32
40/33
90
110
140
160
Soundscreen
(a) Nil
34/27
35/28
38/30
38/31
1 x 10mm GYPROCK
AQUACHEK plasterboard.
38/29
39/30
41/32
42/33
Side two
39/26
40/30
42/32
43/33
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
36/29
37/30
38/31
39/32
90
110
140
160
(a) Nil
37/30
38/31
40/34
41/35
Both SideS
41/32
42/33
44/36
45/37
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
42/32
43/33
45/36
46/37
39/32
40/33
41/35
42/36
96
116
146
166
(a) Nil
42/35
44/38
45/39
46/40
Both SideS
46/37
48/40
49/41
50/42
2 x 10mm GYPROCK
SUPERCHEK
plasterboard.
47/37
49/40
50/41
51/42
44/37
46/40
46/40
47/41
110
130
160
180
(a) Nil
33/26
34/27
37/30
37/30
37/28
38/29
41/32
41/32
38/28
39/29
42/32
42/32
35/28
36/29
39/32
38/31
89
119
139
159
(a) Nil
35/28
37/30
39/32
39/32
39/30
41/32
43/34
43/34
40/30
42/32
44/34
44/34
37/30
39/32
41/34
40/33
92
112
142
162
WALL THICKNESS mm
WALL THICKNESS mm
CsR 335
//
WALL THICKNESS mm
CsR 326
Side one
1 x 13mm GYPROCK
Plasterboard CD.
//
Side two
1 x 6mm CeminSeal
Wallboard.
CsR 327
//
Side one
1 x 13mm GYPROCK
Plasterboard CD.
Side two
1 x 9mm CeminSeal
Wallboard.
140
Side one
CsR 354
//
120
35/28
WALL THICKNESS mm
CsR 330
90
Rw / Rw+Ctr
(Refer to Section A)
CsR 325
//
70
CAViTY iNFiLL
WALL THICKNESS mm
WALL THICKNESS mm
C7
ACousTiC
oPiNioN
PKA-051
FRL
Report/Opinion
sYsTEm
N
sTud dEPTh mm
WALL LiNiNgs
(a) Nil
37/30
38/31
38/29
39/30
41/32
42/33
2.0
39/29
40/30
42/32
43/33
36/29
37/30
38/31
39/32
82
102
132
152
(a) Nil
41/34
43/37
45/39
45/39
45/36
47/39
49/41
49/41
46/36
48/39
50/41
50/41
1 x 6mm CeminSeal
Wallboard.
43/36
45/39
46/40
46/40
102
122
152
172
Soundscreen
WALL THICKNESS mm
Both SideS (Any order)
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
CsR 352
/60/60
and
30/30/30
FAR 2303
WALL THICKNESS mm
(a) Nil
38/31
39/32
42/35
42/36
1 x 10mm GYPROCK
Plasterboard CD.
42/33
43/34
46/37
46/38
1 x 13mm GYPROCK
FYRCHEK plasterboard.
43/33
44/34
47/37
47/38
Side two
40/33
41/34
43/36
43/37
106
126
156
176
(a) Nil
35/28
37/30
38/31
39/33
39/30
41/32
42/33
43/35
40/30
42/32
43/33
44/35
37/30
39/32
39/32
40/34
96
116
146
166
(a) Nil
34/27
36/29
39/33
39/33
38/29
40/31
43/35
43/35
39/29
41/31
44/35
44/35
36/29
39/32
40/34
40/34
102
122
152
172
(a) Nil
41/34
43/37
45/39
45/39
45/36
47/39
49/41
49/41
46/36
48/39
50/41
50/41
43/36
45/39
46/40
46/40
108
128
158
178
1 x 13mm GYPROCK
FYRCHEK plasterboard.
CsR 350
/60/60
and
30/30/30
Both SideS
1 x 13mm GYPROCK
FYRCHEK plasterboard.
FAR 2303
WALL THICKNESS mm
WALL THICKNESS mm
CsR 355
/60/60
and
60/60/60
Both SideS
1 x 16mm GYPROCK
FYRCHEK plasterboard.
FAR 2303
WALL THICKNESS mm
CsR 660
/60/60
and
60/60/60
FAR 2303
Both SideS
1 x 6mm CeminSeal
Wallboard (against studs).
1 x 13mm GYPROCK
FYRCHEK plasterboard.
WALL THICKNESS mm
C8
140
35/28
1 x 6mm CeminSeal
Wallboard.
//
120
34/27
Both SideS
CsR 653
90
Rw / Rw+Ctr
(Refer to Section A)
CsR 654
//
70
CAViTY iNFiLL
ACousTiC
oPiNioN
PKA-051
FRL
Report/Opinion
sYsTEm
N
CsR 652
/90/90
and
60/60/60
Side one
Side Two
2 x 16mm GYPROCK
FYRCHEK plasterboard.
CsR 665
Both SideS
1 x 6mm CeminSeal
Wallboard (against studs).
1 x 16mm GYPROCK
FYRCHEK plasterboard.
* ACR Group 3
FAR 2303
/90/90
and
60/60/60
FAR 2303
(a) Nil
39/32
41/34
42/36
43/37
43/34
45/36
46/38
47/39
2.0
44/34
46/36
47/38
48/39
41/34
43/36
43/37
44/38
118
138
168
188
(a) Nil
43/37
44/38
45/39
46/40
47/39
48/40
49/41
50/42
48/39
49/40
50/41
51/42
45/39
46/40
46/40
47/41
114
134
164
184
Soundscreen
WALL THICKNESS mm
(a) Nil
43/37
44/38
45/39
46/40
47/39
48/40
49/41
50/42
1 x 16mm GYPROCK
FYRCHEK plasterboard.
48/39
49/40
50/41
51/42
Side two
45/39
46/40
46/40
47/41
124
144
174
194
42/36
44/38
45/39
46/40
46/38
48/40
49/41
50/42
47/38
49/40
50/41
51/42
44/38
46/40
46/40
47/41
122
142
172
192
42/36
44/39
45/39
45/39
46/38
48/40
49/41
49/41
2.0
47/38
49/40
50/41
50/41
44/38
46/40
46/40
46/40
134
154
184
204
WALL THICKNESS mm
(a) Nil
Both SideS
2 x 13mm GYPROCK
FYRCHEK plasterboard.
FAR 2303
(b) 75 Gold
Batts
1.5
WALL THICKNESS mm
CsR 380
FAR 2303
(a) Nil
Both SideS
2 x 16mm GYPROCK
FYRCHEK plasterboard.
Soundscreen
WALL THICKNESS mm
140
CsR 375
/120/120
and
120/120/120
120
1 x 6mm CeminSeal
Wallboard.
2 x 16mm GYPROCK
FYRCHEK plasterboard.
/120/120
and
90/90/90
90
Rw / Rw+Ctr
WALL THICKNESS mm
CsR 667
70
CAViTY iNFiLL
(Refer to Section A)
1 x 16mm GYPROCK
FYRCHEK plasterboard.
FAR 2303
/90/90
60/60/60
90/90/90*
sTud dEPTh mm
WALL LiNiNgs
C9
ACousTiC
oPiNioN
PKA-051
Discontinuous
Construction
sYsTEm
N
sTud dEPTh mm
WALL LiNiNgs
CAViTY iNFiLL
48/42
49/43
50/44
Both SideS
55/47
57/49
58/50
59/51
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
56/47
58/49
59/50
60/51
54/48
56/50
57/51
58/52
186
226
286
326
(a) Nil
44/37
45/39
48/42
49/43
53/44
54/46
57/49
58/50
54/44
55/46
58/49
59/50
52/45
53/47
56/50
57/51
172
212
272
312
(a) Nil
48/42
49/43
50/44
51/45
57/49
58/50
59/51
60/52
58/49
59/50
60/51
61/52
56/50
57/51
58/52
59/53
178
213
278
318
(a) Nil
45/39
47/41
49/43
50/44
54/46
56/48
58/50
59/51
55/46
57/48
59/50
60/51
53/47
55/49
57/51
58/52
186
226
286
326
(a) Nil
50/44
52/46
53/47
54/48
59/51
61/53
62/54
63/55
60/51
62/53
63/54
64/55
58/52
60/54
61/55
62/56
212
252
312
352
(a) Nil
45/39
46/40
48/42
49/43
54/46
55/47
47/49
58/50
55/46
56/47
58/49
59/50
53/47
54/48
56/50
57/51
192
232
292
332
Both SideS
1 x 6mm CeminSeal
Wallboard .
WALL THICKNESS mm
CsR 675
Both SideS
1 x 9mm CeminSeal
Wallboard.
WALL THICKNESS mm
CsR 550
/60/60
and
30/30/30
Both SideS
1 x 13mm GYPROCK
FYRCHEK plasterboard.
FAR 2303
WALL THICKNESS mm
CsR 677
Both SideS (Any order)
/60/60
and
30/30/30
1 x 13mm GYPROCK
Plasterboard CD.
1 x 13mm GYPROCK
FYRCHEK plasterboard.
FAR 2303
WALL THICKNESS mm
CsR 555
/60/60
and
60/60/60
FAR 2303
Both SideS
1 x 16mm GYPROCK
FYRCHEK plasterboard.
WALL THICKNESS mm
C10
140
46/40
CsR 674
//
120
(a) Nil
WALL THICKNESS mm
//
90
Rw / Rw+Ctr
(Refer to Section A)
CsR 553
//
70
ACousTiC
oPiNioN
PKA-051
Discontinuous
Construction
sYsTEm
N
sTud dEPTh mm
WALL LiNiNgs
CAViTY iNFiLL
Both SideS
1 x 16mm GYPROCK
FYRCHEK plasterboard.
FAR 2303
Both SideS
/60/60
and
60/60/60
1 x 10mm GYPROCK
Plasterboard CD.
1 x 16mm GYPROCK
FYRCHEK plasterboard.
FAR 2303
/60/60
and
60/60/60
46/40
48/42
49/43
58/50
59/51
61/53
61/53
59/50
60/51
62/53
62/53
57/51
58/52
59/53
60/54
192
232
292
332
(a) Nil
50/44
52/46
53/47
54/48
59/51
61/53
62/54
63/55
60/51
62/53
63/54
64/55
58/52
60/54
61/55
62/56
212
252
312
352
Side one
(a) Nil
48/42
50/44
51/45
52/46
1 x 16mm GYPROCK
FYRCHEK plasterboard.
57/49
59/51
60/52
61/53
58/49
60/51
61/52
62/53
56/50
58/52
59/53
60/54
198
238
298
338
(a) Nil
51/45
52/46
53/47
54/48
60/52
61/53
62/54
63/55
61/52
62/53
63/54
64/55
59/53
60/54
61/55
62/56
198
238
298
338
(a) Nil
51/45
52/46
54/48
55/49
60/52
61/53
63/55
64/56
61/52
62/53
64/55
65/56
59/53
60/54
62/56
63/57
204
244
304
344
(a) Nil
51/45
52/46
54/48
55/49
60/52
61/53
63/55
64/56
61/52
62/53
64/55
65/56
59/53
60/54
62/56
63/57
204
244
304
344
FAR 2303
1 x 6mm CeminSeal
Wallboard
CsR 680
Both SideS
/60/60
and
60/60/60
1 x 6mm CeminSeal
Wallboard (against studs).
1 x 13mm GYPROCK
FYRCHEK plasterboard.
FAR 2303
WALL THICKNESS mm
WALL THICKNESS mm
CsR 681
/60/60
and
60/60/60
Both SideS
1 x 16mm GYPROCK
FYRCHEK plasterboard
(against studs).
1 x 6mm CeminSeal
Wallboard.
FAR 2303
CsR 682
/90/90
60/60/60
90/90/90*
* ACR Group 3
FAR 2303
Both SideS
1 x 6mm CeminSeal
Wallboard (against studs).
1 x 16mm GYPROCK
FYRCHEK plasterboard.
WALL THICKNESS mm
WALL THICKNESS mm
140
45/39
WALL THICKNESS mm
CsR 579
120
(a) Nil
WALL THICKNESS mm
CsR 678
90
Rw / Rw+Ctr
(Refer to Section A)
CsR 556
/60/60
and
60/60/60
70
C11
ACousTiC
oPiNioN
PKA-051
Discontinuous
Construction
sYsTEm
N
sTud dEPTh mm
WALL LiNiNgs
CAViTY iNFiLL
Both SideS
2 x 13mm GYPROCK
FYRCHEK plasterboard.
FAR 2303
/120/120
and
120/120/120
Both SideS
2 x 16mm GYPROCK
FYRCHEK plasterboard.
FAR 2303
/120/120
and
120/120/120
FAR 2303
Both SideS
3 x 16mm GYPROCK
FYRCHEK plasterboard.
52/46
54/48
54/48
60/52
61/53
63/55
63/55
61/52
62/53
64/55
64/55
59/53
60/54
62/56
62/56
212
252
312
352
(a) Nil
51/45
52/46
53/47
54/48
60/52
61/53
62/54
63/55
61/52
62/53
63/54
64/55
59/53
60/54
61/55
62/56
224
264
324
364
(a) Nil
54/48
55/49
56/50
57/51
63/55
64/56
65/57
66/58
64/55
65/56
66/57
67/58
62/56
63/57
64/58
65/59
256
296
356
396
WALL THICKNESS mm
C12
140
51/45
WALL THICKNESS mm
CsR 582
120
(a) Nil
WALL THICKNESS mm
CsR 580
90
Rw / Rw+Ctr
(Refer to Section A)
CsR 575
/120/120
and
90/90/90
70
Timber Frame internal Wall systems Party Wall with 25mm Fire Barrier
sYsTEm sPECiFiCATioN
ACousTiC
oPiNioN
PKA-018
Discontinuous
Construction
sYsTEm
N
sTud dEPTh mm
WALL LiNiNgs
CsR 360
CAViTY iNFiLL
Both sides (Refer to section A)
70
90
Rw / Rw+Ctr
60/47
61/49
60/60/60
Both SideS
61/48
62/50
EWFA 45743
1 x 10mm GYPROCK
SUPERCHEK.
61/48
62/50
225
265
61/49
62/50
WALL THICKNESS mm
CsR 361
60/60/60
Both SideS
62/50
63/51
EWFA 45743
2 x 10mm GYPROCK
Plasterboard CD.
62/50
63/51
245
285
61/49
62/50
WALL THICKNESS mm
CsR 362
60/60/60
Both SideS
62/50
63/51
EWFA 45743
1 x 13mm GYPROCK
SOUNDCHEK.
62/50
63/51
231
271
62/50
63/51
WALL THICKNESS mm
CsR 363
Both SideS (Any order)
60/60/60
1 x 6mm CeminSeal
Wallboard.
62/50
63/51
EWFA 45743
1 x 10mm GYPROCK
AQUACHEK plasterboard.
63/51
64/52
237
277
WALL THICKNESS mm
CsR 364
60/60/60
EWFA 45743
61/49
62/50
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
62/50
63/51
63/51
64/52
245
285
1 x 10mm GYPROCK
plasterboard CD.
WALL THICKNESS mm
C13
Timber Frame internal Wall systems Party Wall with 41mm Fire Barrier
sYsTEm sPECiFiCATioN
ACousTiC
oPiNioN
PKA-018
Discontinuous
Construction
sYsTEm
N
sTud dEPTh mm
WALL LiNiNgs
CAViTY iNFiLL
Both sides (Refer to Section A)
CsR 368
70
90
Rw / Rw+Ctr
63/51
64/52
90/90/90
Both SideS
64/52
65/53
EWFA 45743
1 x 10mm GYPROCK
SUPERCHEK
63/50
64/51
241
281
64/52
65/53
WALL THICKNESS mm
CsR 369
90/90/90
Both SideS
65/53
66/54
EWFA 45743
2 x 10mm GYPROCK
Plasterboard CD
64/51
65/52
261
301
64/52
65/53
WALL THICKNESS mm
CsR 370
90/90/90
Both SideS
65/53
66/54
EWFA 45743
1 x 13mm GYPROCK
SOUNDCHEK
64/51
65/52
247
287
63/50
64/52
WALL THICKNESS mm
CsR 371
90/90/90
Both SideS
64/51
65/53
EWFA 45743
1 x 6mm CeminSeal
Wallboard
64/50
65/52
233
273
63/51
64/52
WALL THICKNESS mm
CsR 372
90/90/90
Both SideS
64/52
65/53
EWFA 45743
1 x 13mm GYPROCK
AQUACHEK Plasterboard
63/50
64/51
247
287
WALL THICKNESS mm
C14
ACousTiC
oPiNioN
PKA-051
NOT
Deemed
Discontinuous
Construction
FRL
Report/Opinion
sYsTEm
N
WALL LiNiNgs
CsR 425
(a) Nil
Both SideS
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
//
PLATE WidTh mm
Both SideS
//
1 x 13mm GYPROCK
Plasterboard CD.
Side one
1 x 10mm GYPROCK
Plasterboard CD.
//
Side two
1 x 6mm CeminSeal
Wallboard.
CsR 662
//
Side one
1 x 10mm GYPROCK
SUPERCHEK.
Side two
1 x 6mm CeminSeal
Wallboard.
140
43/36
44/37
50/41
52/43
53/44
2.0
51/41
53/43
54/44
48/41
49/42
50/43
110
140
160
(a) Nil
40/33
41/34
43/36
49/40
50/41
52/43
50/40
51/41
53/43
47/40
47/40
49/42
116
146
166
(a) Nil
38/31
40/33
41/34
47/38
49/40
50/41
48/38
50/40
51/41
45/38
46/39
47/40
106
136
156
(a) Nil
41/34
43/36
44/37
50/41
52/43
53/44
51/41
53/43
54/44
48/41
49/42
50/43
106
136
156
Soundscreen
WALL THICKNESS mm
CsR 661
120
Rw / Rw+Ctr
41/34
WALL THICKNESS mm
CsR 422
90
WALL THICKNESS mm
WALL THICKNESS mm
C15
ACousTiC
oPiNioN
PKA-051
NOT
Deemed
Discontinuous
Construction
FRL
Report/Opinion
sYsTEm
N
PLATE WidTh mm
WALL LiNiNgs
CAViTY iNFiLL
40/33
42/35
43/36
49/40
51/42
52/43
50/40
52/42
53/43
47/40
48/41
49/42
102
132
152
(a) Nil
44/37
45/39
47/41
53/44
54/46
56/48
54/44
55/46
57/48
51/44
51/45
53/47
108
138
158
(a) Nil
40/33
41/34
43/36
49/40
50/41
52/43
50/40
51/41
53/43
47/40
47/40
49/42
109
139
159
(a) Nil
49/43
50/44
51/45
Both SideS
58/50
59/51
60/52
2 x 10mm GYPROCK
SUPERCHEK
plasterboard.
59/50
60/51
61/52
56/50
56/50
57/51
130
160
180
(a) Nil
41/34
44/37
44/38
50/41
53/44
53/45
51/41
54/44
54/45
48/41
50/43
50/44
116
146
166
(a) Nil
42/35
43/37
44/38
51/42
52/44
53/45
52/42
53/44
54/45
49/42
49/43
50/44
122
152
172
1 x 6mm CeminSeal
Wallboard.
WALL THICKNESS mm
CsR 664
Both SideS
1 x 9mm CeminSeal
Wallboard.
WALL THICKNESS mm
CsR 666
Side one
1 x 13mm GYPROCK
Plasterboard CD.
//
Side two
1 x 6mm CeminSeal
Wallboard.
CsR 430
//
WALL THICKNESS mm
WALL THICKNESS mm
CsR 450
/60/60
and
30/30/30
Both SideS
1 x 13mm GYPROCK
FYRCHEK plasterboard.
FAR 2303
WALL THICKNESS mm
CsR 455
/60/60
and
60/60/60
FAR 2303
Both SideS
1 x 16mm GYPROCK
FYRCHEK plasterboard.
WALL THICKNESS mm
C16
140
(a) Nil
Both SideS
//
120
Rw / Rw+Ctr
(Refer to Section A)
CsR 663
//
90
ACousTiC
oPiNioN
PKA-051
NOT
Deemed
Discontinuous
Construction
FRL
Report/Opinion
sYsTEm
N
PLATE WidTh mm
WALL LiNiNgs
Both SideS
1 x 6mm CeminSeal
Wallboard.(against studs).
1 x 13mm GYPROCK
FYRCHEK plasterboard.
FAR 2303
CAViTY iNFiLL
/60/60
and
60/60/60
Both SideS
1 x 16mm GYPROCK
FYRCHEK plasterboard
(against studs).
1 x 6mm CeminSeal
Wallboard.
FAR 2303
CsR 672
/90/90
and
90/90/90*
Both SideS
1 x 6mm CeminSeal
Wallboard (against studs).
* ACR Group 3
1 x 16mm GYPROCK
FYRCHEK plasterboard.
FAR 2303
48/42
49/43
50/44
57/49
58/50
59/51
58/49
59/50
60/51
55/49
55/49
56/50
128
158
178
(a) Nil
49/43
50/44
51/45
58/50
59/51
60/52
59/50
60/51
61/52
59/50
56/50
57/51
134
164
184
(a) Nil
49/43
50/44
51/45
58/50
59/51
60/52
59/50
60/51
61/52
59/50
56/50
57/51
134
164
184
(a) Nil
49/43
50/44
51/45
58/50
59/51
60/52
59/50
60/51
61/52
56/50
56/50
57/51
142
172
192
(a) Nil
48/42
49/43
50/44
57/49
58/50
59/51
58/49
59/50
60/51
55/49
55/49
56/50
154
184
204
WALL THICKNESS mm
WALL THICKNESS mm
CsR 475
/120/120
and
90/90/90
Both SideS
2 x 13mm GYPROCK
FYRCHEK plasterboard.
FAR 2303
WALL THICKNESS mm
CsR 480
/120/120
and
120 /120/120
FAR 2303
Both SideS
2 x 16mm GYPROCK
FYRCHEK plasterboard.
WALL THICKNESS mm
140
(a) Nil
WALL THICKNESS mm
CsR 671
120
Rw / Rw+Ctr
(Refer to Section A)
CsR 670
/60/60
and
60/60/60
90
C17
ACousTiC
oPiNioN
PKA-051
NOT
Deemed
Discontinuous
Construction
FRL
Report/Opinion
sYsTEm
N
sTud dEPTh mm
WALL LiNiNgs
CAViTY iNFiLL
44/38
45/39
46/40
Both SideS
50/41
52/44
53/45
53/45
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
51/41
53/44
54/45
54/45
48/41
50/44
50/44
51/45
124
144
174
194
42/35
43/36
45/38
45/39
50/41
51/42
53/44
52/44
2.0
51/41
52/42
54/44
53/44
48/41
49/42
50/43
50/44
117
137
167
187
Side two
1 x 6mm CeminSeal
Wallboard.
CsR 403
//
47/40
48/42
48/42
53/44
55/46
56/48
55/47
54/44
56/46
57/48
56/47
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
51/44
53/46
53/47
53/47
128
148
178
198
(a) Nil
44/37
45/38
47/40
47/40
52/43
53/44
55/46
54/45
53/43
54/44
56/46
55/45
50/43
51/44
52/45
52/45
128
148
178
198
44/37
46/39
47/40
48/42
52/43
54/45
55/46
55/47
53/43
55/45
56/46
56/47
50/43
52/45
52/45
53/47
124
144
174
194
C18
45/38
1 x 10mm GYPROCK
AQUACHEK plasterboard.
//
(c) 75
Soundscreen
(a) Nil
Side two
CsR 411
2 x 10mm GYPROCK
SUPERCHEK
plasterboard.
2 x 10mm GYPROCK
SUPERCHEK
plasterboard.
//
(a) Nil
Side Two
CsR 410
140
42/35
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
//
120
(a) Nil
CsR 407
90
Rw / Rw+Ctr
(Refer to Section A)
CsR 406
//
70
Batts
1.5
ACousTiC
oPiNioN
PKA-051
NOT
Deemed
Discontinuous
Construction
FRL
Report/Opinion
sYsTEm
N
sTud dEPTh mm
WALL LiNiNgs
CAViTY iNFiLL
Both SideS
1 x 16mm GYPROCK
FYRCHEK plasterboard.
FAR 2303
/120/120
and
90/90/90
2 x 13mm GYPROCK
FYRCHEK plasterboard.
FAR 2303
43/37
44/38
44/38
49/40
51/43
52/44
51/43
50/40
52/43
53/44
52/43
47/40
49/43
49/43
49/43
130
150
180
200
48/42
49/43
50/44
51/45
56/48
57/49
58/50
58/50
2.0
57/48
58/49
59/50
59/50
54/48
55/49
55/49
56/50
150
170
200
220
(a) Nil
48/42
49/43
50/44
50/44
56/48
57/49
58/50
57/49
57/48
58/49
59/50
58/49
54/48
55/49
55/49
55/49
162
182
212
232
Soundscreen
CsR 419
/120/120
and
120/120/120
FAR 2303
Both SideS
2 x 16mm GYPROCK
FYRCHEK plasterboard.
140
41/34
(a) Nil
Both SideS
120
(a) Nil
CsR 415
90
Rw / Rw+Ctr
(Refer to Section A)
CsR 414
/60/60
and
60/60/60
70
C19
ACousTiC
oPiNioN
PKA-051
FRL
Report/Opinion
sYsTEm
N
WALL LiNiNgs
sTud dEPTh mm
CAViTY iNFiLL (Refer to Section A)
70
Rw / Rw+Ctr
CsR 386
one Side only
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
//
(a) Nil
26/24
WALL THICKNESS mm
80
CsR 387
one Side only
//
(a) Nil
26/24
1 x 13mm GYPROCK
Plasterboard CD.
WALL THICKNESS mm
83
CsR 388
one Side only
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
//
(a) Nil
30/28
WALL THICKNESS mm
83
CsR 389
one Side only
//
(a) Nil
29/27
1 x 16mm GYPROCK
FYRCHEK plasterboard.
WALL THICKNESS mm
C20
86
ACousTiC
oPiNioN
PKA-051
FRL
Report/Opinion
/30/30
and
30/30/30
sYsTEm
N
(a) Nil
Rw / Rw+Ctr
35/32
WALL THICKNESS mm
96
CsR 391
one Side only
(a) Nil
35/32
2 x 16mm GYPROCK
FYRCHEK plasterboard.
WALL THICKNESS mm
102
CsR 392
one Side only
(a) Nil
38/35
3 x 13mm GYPROCK
FYRCHEK plasterboard.
/120/120
and
120/120/120
70
2 x 13mm GYPROCK
FYRCHEK plasterboard.
/90/90
and
90/90/90
sTud dEPTh mm
CsR 390
/60/60
and
60/60/60
WALL LiNiNgs
WALL THICKNESS mm
109
CsR 393
one Side only
(a) Nil
38/35
3 x 16mm GYPROCK
FYRCHEK plasterboard.
WALL THICKNESS mm
118
C21
ACousTiC
oPiNioN
PKA-055
Sarking.
Lining material as per system table to external side.
Timber studs at 600mm maximum centres.
Cavity insulation as per system table.
Lining material as per system table to internal side.
NOTES:
*ACR = Axial Capacity Reduction. (Refer to Table C3).
Acoustic performance valid for 35mm wide studs at
600mm centres.
FRL
Report/Opinion
sYsTEm
N
CsR 906
WALL LiNiNgs
Rt(sum)
(a) Nil
35
1.0
0.9
38
2.4
2.2
39
2.9
2.7
154
(a) Nil
36
1.0
1.0
1 x 16mm GYPROCK
FYRCHEK MR plasterboard.
39
2.4
2.2
40
3.0
2.7
157
(a) Nil
38
1.1
1.0
1 x 16mm GYPROCK
FYRCHEK MR plasterboard.
41
2.5
2.3
42
3.0
2.8
163
(a) Nil
38
1.1
1.0
2 x 13mm GYPROCK
FYRCHEK MR plasterboard.
41
2.4
2.2
42
2.9
2.7
167
(a) Nil
40
1.1
1.1
43
2.4
2.2
44
3.0
2.7
173
(a) Nil
44
1.3
1.2
47
2.6
2.4
48
3.1
2.8
195
CsR 900
60/60/60*
from outside only
* ACR Group 2
FAR 2303
CsR 901
60/60/60
FAR 2303
1 x 16mm GYPROCK
FYRCHEK plasterboard.
CsR 907
90/90/90
from outside only
FAR 2303
1 x 10mm GYPROCK
Plasterboard CD.
CsR 908
FAR 2303
1 x 10mm GYPROCK
Plasterboard CD.
CsR 909
120/120/120
FAR 2303
120/120/120
from outside only
C22
ThERmAL
Rt(win)
FAR 2303
90
Rw
1 x 16mm GYPROCK
FYRCHEK MR plasterboard.
30/30/30
sTud dEPTh mm
CAViTY iNFiLL (Refer to Section A)
ACousTiC
oPiNioN
Sarking.
Lining material as per system table to external side.
Timber studs at 600mm maximum centres.
Cavity insulation as per system table.
Lining material as per system table to internal side.
NOTES:
*ACR = Axial Capacity Reduction. (Refer to Table C3).
Acoustic performance valid for 35mm wide studs at
600mm centres.
FRL
Report/Opinion
sYsTEm
N
WALL LiNiNgs
externAl wAll Side
60/60/60
and
(90/90/90*
CsR 911
1 x 6mm
CSR CeminSeal
Wallboard (against studs)
1 x 16mm GYPROCK
FYRCHEK MR
plasterboard.
1 x 16mm GYPROCK
FYRCHEK plasterboard.
externAl wAll Side
CsR 912
* ACR Group 3
FAR 2303
90
ThERmAL
Rw
Rt(win)
Rt(sum)
(a) Nil
40
1.1
1.0
43
2.5
2.3
44
3.0
2.8
FAR 2303
90/90/90*
sTud dEPTh mm
CAViTY iNFiLL (Refer to Section A)
1 x 6mm
CSR CeminSeal
Wallboard (against studs)
1 x 16mm GYPROCK
FYRCHEK MR
plasterboard.
169
(a) Nil
44
1.2
1.1
48
2.5
2.3
49
3.0
2.8
179
C23
Timber Frame External Wall systems Texture Base sheet for houses
sYsTEm sPECiFiCATioN
ACousTiC
oPiNioN
Sarking.
Lining material as per system table to external side.
Timber studs at 600mm maximum centres.
Cavity insulation as per system table.
Lining material as per system table to internal side.
NOTES:
*ACR = Axial Capacity Reduction. (Refer to Table C3).
Acoustic performance valid for 35mm wide studs at 600mm
centres.
FRL
Report/Opinion
sYsTEm
N
CsR 902
60/60/60*
from outside only
60/60/60*
* ACR Group 1
FAR 2303
60/60/60
and
90/90/90*
* ACR Group 3
FAR 2303
C24
0.5
1 x 13mm GYPROCK
FYRCHEK MR plasterboard.
46/37
3.2
2.9
45/35
2.4
2.2
120
(a) Nil
40/33
0.5
0.5
1 x 13mm GYPROCK
FYRCHEK MR plasterboard.
46/37
3.2
2.9
45/35
2.5
2.3
WALL THICKNESS mm
126
(a) Nil
45/39
0.6
0.6
1 x 16mm GYPROCK
FYRCHEK MR plasterboard.
51/43
3.3
3.0
50/41
2.5
2.3
2 x 13mm GYPROCK
FYRCHEK plasterboard.
CsR 916
WALL THICKNESS mm
FAR 2303
Rt(sum)
0.5
1 x 16mm GYPROCK
FYRCHEK plasterboard.
* ACR Group 3
ThERmAL
Rt(win)
40/33
CsR 915
90
Rw / Rw+Ctr
(a) Nil
1 x 10mm GYPROCK
Plasterboard CD.
CsR 903
sTud dEPTh mm
CAViTY iNFiLL (Refer to Section A)
* ACR Group 1
FAR 2303
60/60/60
and
90/90/90*
WALL LiNiNgs
WALL THICKNESS mm
139
(a) Nil
45/39
0.6
0.6
51/43
3.2
3.0
50/41
2.5
2.3
WALL THICKNESS mm
135
ACousTiC
oPiNioN
2010675.1/
2401A/R1/Jh
FRL
Report/Opinion
sYsTEm
N
WALL LiNiNgs
hEBEL 1400
240/180/180
from outside only
FSV 0536
sTud dEPTh mm
90
Rw / Rw+Ctr
(a) Nil
46/40
ThERmAL
Rt(win)
Rt(sum)
46/40
0.9
0.9
53/44
53/45
2.8
2.6
177
197
70
C25
ACousTiC
oPiNioN
PKA-055
sYsTEm
N
CsR 923
60/60/60
from outside only
WALL LiNiNgs
60/60/60
from outside only
CsR 925
60/60/60
from outside only
CsR 920
60/60/60
FAR 2303
60/60/60*
59/50
2.1
2.0
60/51
3.2
2.9
* ACR Group 1
FAR 2303
Refer to masonry
manufacturer
C26
WALL THICKNESS mm
250
externAl Side
(a) Nil
53/46
0.5
0.5
60/53
2.1
2.0
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
61/54
3.2
2.9
externAl Side
(a) Nil
56/49
0.6
0.6
63/56
2.2
2.0
2 x 10mm GYPROCK
SUPERCHEK
plasterboard.
64/57
3.2
3.0
externAl Side
(a) Nil
54/46
0.6
0.6
61/53
2.2
2.0
62/54
3.2
2.9
1 x 16mm GYPROCK
FYRCHEK plasterboard.
CsR 927
Rt(sum)
0.5
internAl Side
Refer to masonry
manufacturer
Rt(win)
0.5
internAl Side
Refer to masonry
manufacturer
Rw / Rw+Ctr
52/44
internAl Side
Refer to masonry
manufacturer
ThERmAL
(a) Nil
1 x 10mm GYPROCK
Plasterboard CD.
CsR 924
90
externAl Side
internAl Side
Refer to masonry
manufacturer
sTud dEPTh mm
externAl Side
Masonry veneer wall with
FRL 60/60/60.
internAl Side
1 x 6mm CeminSeal
Wallboard (against studs).
1 x 13mm GYPROCK
FYRCHEK plasterboard.
WALL THICKNESS mm
WALL THICKNESS mm
WALL THICKNESS mm
250
260
256
(a) Nil
54/46
0.6
0.6
61/53
2.2
2.0
62/54
3.2
2.9
WALL THICKNESS mm
259
ACousTiC
oPiNioN
PKA-055
sYsTEm
N
CsR 921
90/90/90
internAl Side
Refer to masonry
manufacturer
* ACR Group 3
FAR 2303
Refer to masonry
manufacturer
externAl Side
Masonry veneer wall with
FRL 90/90/90.
FAR 2303
90/90/90*
WALL LiNiNgs
2 x 13mm GYPROCK
FYRCHEK plasterboard.
CsR 928
externAl Side
Masonry veneer wall with
FRL 90/90/90.
internAl Side
1 x 6mm CeminSeal
Wallboard (against studs).
1 x 16mm GYPROCK
FYRCHEK plasterboard.
sTud dEPTh mm
CAViTY iNFiLL (Refer to Section A)
90
ThERmAL
Rw / Rw+Ctr
Rt(win)
Rt(sum)
(a) Nil
56/49
0.6
0.6
63/56
2.2
2.0
64/57
3.3
3.0
WALL THICKNESS mm
266
(a) Nil
56/49
0.6
0.6
63/56
2.2
2.0
64/57
3.2
3.0
WALL THICKNESS mm
262
C27
ACousTiC
oPiNioN
PKA-051
Sarking.
Timber studs at 600mm maximum centres.
Cavity insulation as per system table.
Lining material as per system table to internal side.
NOTES:
Acoustic performance valid for 35mm wide studs at 600mm
centres.
FRL
Report/Opinion
sTud dEPTh mm
90
Rw
Rt(win)
Rt(sum)
(a) Nil
39
1.7
1.5
internAl Side
45
2.5
2.3
1 x 10mm GYPROCK
Plasterboard CD.
45
3.6
3.3
sYsTEm
N
WALL LiNiNgs
CsR 690
//
WALL THICKNESS mm
sYsTEm sPECiFiCATioN
ThERmAL
143
ACousTiC
oPiNioN
Sarking.
1 x 13mm GYPROCK FYRCHEK MR plasterboard.
Timber studs at 600mm maximum centres.
Cavity insulation as per system table.
Lining material as per system table to internal side.
NOTES:
*ACR = Axial Capacity Reduction. (Refer to Table C3).
Acoustic performance valid for 35mm wide studs at 600mm
centres.
FRL
Report/Opinion
sYsTEm
N
CsR 693
60/60/60
sTud dEPTh mm
90
Rw
Rt(win)
Rt(sum)
externAl Side
(a) Nil
45
1.2
1.1
As per system
specification.
51
2.6
2.4
53
3.7
3.4
WALL LiNiNgs
internAl Side
FAR 2303
1 x 16mm GYPROCK
FYRCHEK plasterboard.
CsR 696
60/60/60*
From outside only
* ACR Group 2
FAR 2303
C28
WALL THICKNESS mm
ThERmAL
162
externAl Side
(a) Nil
43
1.2
1.1
As per system
specification.
49
2.6
2.4
51
3.7
3.3
internAl Side
1 x 10mm GYPROCK
Plasterboard CD.
WALL THICKNESS mm
156
ACousTiC
oPiNioN
PKA-051
sTud dEPTh mm
90
Rw
Rt(win)
Rt(sum)
externAl Side
(a) Nil
48
1.8
1.6
As per system
specification.
50
2.6
2.4
50
3.6
3.3
sYsTEm
N
CsR 694
60/60/60
WALL LiNiNgs
internAl Side
FAR 2303
1 x 16mm GYPROCK
FYRCHEK plasterboard.
CsR 697
60/60/60
From outside only
149
externAl Side
(a) Nil
45
1.8
1.5
As per system
specification.
47
2.6
2.3
47
3.6
3.3
internAl Side
FAR 2303
WALL THICKNESS mm
ThERmAL
1 x 10mm GYPROCK
Plasterboard CD.
WALL THICKNESS mm
sYsTEm sPECiFiCATioN
143
ACousTiC
oPiNioN
PKA-055
sYsTEm
N
CsR 695
internAl Side
* ACR Group 3
1 x 6mm CeminSeal
Wallboard (against studs).
FAR 2303
90
Rw
Rt(win)
Rt(sum)
(a) Nil
51
1.2
1.2
54
2.6
2.4
55
3.7
3.4
WALL THICKNESS mm
ThERmAL
161
externAl Side
(a) Nil
50
1.3
1.2
As per system
specification.
53
2.7
2.5
54
3.7
3.4
internAl Side
2 x 13mm GYPROCK
FYRCHEK plasterboard.
sTud dEPTh mm
1 x 16mm GYPROCK
FYRCHEK plasterboard.
CsR 698
FAR 2303
externAl Side
As per system specification.
90/90/90*
90/90/90
WALL LiNiNgs
WALL THICKNESS mm
165
C29
ACousTiC
oPiNioN
PKA-055
FRL
Report/Opinion
sYsTEm
N
WALL LiNiNgs
CsR 905
sTud dEPTh mm
90
Rw
Rt(win)
ThERmAL
Rt(sum)
(a) Nil
41
1.2
1.1
46
2.6
2.4
45
60/60/60*
from outside only
* ACR Group 2
FAR 2303
WALL THICKNESS mm
sYsTEm sPECiFiCATioN
160
ACousTiC
oPiNioN
PKA-055
sYsTEm
N
WALL LiNiNgs
CsR 936
externAl Side
//
Masonry veneer
block wall with 1 x
9mm. CSR Cemintel
ExpressWall cladding
system.
internAl Side
1 x 13mm GYPROCK
Plasterboard CD.
C30
sTud dEPTh mm
CAViTY iNFiLL (Refer to Section A)
90
ThERmAL
Rw / Rw+Ctr
Rt(win)
Rt(sum)
(a) Nil
53/39
0.8
0.8
59/45
2.4
2.2
59/45
2.9
2.7
WALL THICKNESS mm
345
sYsTEm sPECiFiCATioN
FRL
Report/Opinion
sYsTEm
N
75mm
max.
WALL LiNiNgs
CsR 493
1 x 13mm
GYPROCK
FYRCHEK
plasterboard.
30/ /
CSIRO
FCO 1494
CsR 494
2 x 13mm
GYPROCK
FYRCHEK
plasterboard.
60/ /
CSIRO
FCO 1494
75mm
max.
CsR 496
2 x 16mm
GYPROCK
FYRCHEK
plasterboard.
90/ /
CSIRO
FCO 1494
CsR 498
120/ /
CSIRO
FCO 1494
3 x 13mm
GYPROCK
FYRCHEK
plasterboard.
300mm max.
Apply External
Angle Bead to all
corners and set
200mm
max.
C31
NoN-FiRE RATEd
Temporary fastener through
block at every second stud
200mm
min. from fastener
Nails 150mm max.
Screws 200mm max.
300mm
max.
300mm
max.
200mm
min. from
fastener
CSR Gyprock Acrylic
Stud Adhesive
Fixing specifications
Nails,
Screws &
Adhesive
Refer to Section A
Location
Field
Sheet
Width
900mm
1200mm
1350mm
Adhesive Daubs at
300mm max. centres
and 200mm min. from
fastener points
Adhesive
Daubs across board
3 daubs
4 daubs
5 daubs
Recessed
Edges
Nail or screw
at each stud
Butt
Joints on
studs
Corners &
Openings
Nails or screws at
300mm max. centres
SUITABLE FOR:
300mm
max.
Fasteners at 10 to 16mm
from sheet edges
NoN-FiRE RATEd
Fixing specifications
Double Nails
50mm apart
at 300mm
max.
centres
OR
Screws
at
400mm
max.
centres
300mm
max.
Nails or
Screws
Refer to Section A
Location
Field
Recessed
Edges
1 Nail or 1 Screw
at each stud
Butt
Joints on
studs
Butt joints
between
studs
Corners &
Openings
Nails or screws at
300mm max. centres
SUITABLE FOR:
C32
Fasteners at 10 to 16mm
from sheet edges
FiRE RATEd
Fixing specifications for
horizontal sheeting
Fasteners
Refer to Section A
Location
Field
Recessed
Edges
Butt
Joints
Nails at
150mm max. centres
or
Screws at
200mm max. centres.
Corners,
Openings,
Top &
Bottom
Nails at
150mm max. centres
or
Screws at
300mm max. centres
300mm min.
300mm
max.
2 Nails
50mm
apart or
1 Screw
SUITABLE FOR:
Fasteners at 10 to 16mm
from sheet edges
FiRE RATEd
Nails at 150mm max.
Screws at 300mm max.
300mm
max.
2 Nails
50mm
apart or
1 Screw
300mm
max.
Refer to Section A
Location
Field
Recessed
Edges
Nails or Screws at
300mm max. centres
Butt
Joints on
noggings
Nails at
150mm max. centres
or
Screws at
200mm max. centres
Corners,
Openings,
Top &
Bottom
Nails at
150mm max. centres
or
Screws at
300mm max. centres
SUITABLE FOR:
C33
FiRE RATEd
Fixing specifications
Nails at 150mm max.
Screws at 300mm max.
300mm min.
2 Nails
50mm
apart or
1 Screw
Fasteners
Refer to Section A
1st Layer
Edges &
Field
Nails or Screws at
600mm max. centres
Recessed
Edges
Butt
Joints
Nails at
150mm max. centres
or
Screws at
200mm max. centres.
Corners &
Openings
Nails at
150mm max. centres
or
Screws at
300mm max. centres
NOTE:
Second layer butt joints may
be formed between studs with
laminating screws at 200mm max.
centres each side of joint.
600mm
max.
SUITABLE FOR:
Fasteners at 10 to 16mm
from sheet edges
Fig C7: iNsTALLATioN dETAiL TimBER sTud WiTh REsiLiENT mouNTEd FuRRiNg ChANNEL
gYPRoCK FYRChEK TWo LAYER hoRiZoNTAL shEETiNg sCREW FixiNg
Rondo Track or Angle
fixed to ceiling frame
FiRE RATEd
Fixing specifications
300mm
max.
300mm min.
600mm
max.
Refer to Section A
1st Layer
Edges &
Field
Fasteners
Field
Recessed
Edges
Butt
Joints
Screws at
200mm max. centres
Corners &
Openings
Screws at
300mm max. centres
NOTE:
Single layer systems are fixed to the
same specifications as detailed for
the 2nd layer.
Second layer butt joints may
be formed between studs with
laminating screws at 200mm max.
centres each side of joint.
200mm
max.
SUITABLE FOR:
Rondo Track or
Angle fixed to floor
C34
Fasteners at 10 to 16mm
from sheet edges
600mm
600mm
Fasteners
Nails or Screws
Refer to Section A
1st Layer
Recessed
Edges,
Field,
Corners &
Openings
Screws or Nails at
600mm max. centres
on studs
300mm
300mm
Recessed
Edges
Screws or Nails at
300mm max. centres
on studs
Field
1 Screw or 2 Nails at
300mm max. centres
on studs
400mm
3rd Layer
Recessed
Edges,
Field,
Corners &
Openings
Laminating screws at
400x400mm max. grid
400mm
Refer to Section Z for
perimeter details
FiRE RATEd
Fixing specifications for
horizontal sheeting
SUITABLE FOR:
Fasteners
Nails or Screws
Refer to Section A
1st Layer
Recessed
Edges,
Field,
Corners &
Openings
Screws or Nails at
600mm max. centres
on studs
Screws or Nails at
600mm max. centres
on studs
Field
1 Screw or 2 Nails at
300mm max. centres
on studs
3rd Layer
Recessed
Edges,
Field,
Corners &
Openings
Laminating screws at
400x400mm max. grid
C35
NoN-FiRE RATEd
Fixing specifications
200mm
max.
200mm
max.
200mm
max.
Nails &
Adhesive
Refer to Section A
Location
Field
Adhesive Daubs at
230mm max. centres
and 200mm min. from
fastener points
3 daubs
4 daubs
5 daubs
Sheet
Width
900mm
1200mm
1350mm
Top &
Bottom
Plates
Nails at 200mm
maximum centres
Recessed
Edges
Nails at
each stud
Butt
Joints
Nails at
200mm max. centres.
Corners &
Openings
Nails at
200mm max. centres
SUITABLE FOR:
230mm
max.
200mm
min.
FiRE RATEd
Studs at 600mm maximum
centres
Fixing specifications
200mm
max.
Fasten GYPROCK
FYRCHEK plasterboard
at 600mm maximum
centres and 10 to 16mm
from sheet edges
CSR Bradford Insulation
where applicable
One layer of GYPROCK
FYRCHEK plasterboard
and one layer of CSR
Fibre Cement Wallboard
to each side of wall
Refer to Section A
1st Layer
Edges &
Field
Nails or Screws at
600mm max. centres
Top &
Bottom
Plates
Nails at
200mm max. centres
Recessed
Edges
Nails at
each stud
Butt
Joints
Nails at
200mm max. centres
Corners &
Openings
Nails at
200mm max. centres
200mm
max.
600mm max.
300mm min.
Fasteners
SUITABLE FOR:
200mm
max.
C36
200mm max.
Fasteners 50mm
min. from sheet
corners
FiRE RATEd
Fixing specifications
200mm
max.
200mm
max.
Refer to Section A
1st Layer
Edges &
Field
Nails or Screws at
600mm max. centres
Sarking
Fasteners
Recessed
Joints,
Field,
Top &
Bottom
Plates
Nails to framing at
200mm max. centres
Corners &
Openings
Nails at
200mm max. centres
SUITABLE FOR:
600mm
max.
200mm
max.
NOTE: Fixing spacings for Cemintel Texture Base Sheet may need to be reduced to meet wind loadings. Refer to
publication NFC122, Cemintel Texture Base Sheet & Texture Coating System guide.
C37
Notes
C38
Section D
Contents
Stud Selection Tables
D2 D3
Introduction
D3
Design Considerations
D3 D4
Installation
D5
Components
D5
System Specifications
Stud One Side
D6 D8
D9 D11
D12 D13
D14 D15
D16 D18
FRL Upgrade
D19 D20
D21
D22 D23
D1
BMT
51
0.5
64
0.75
0.5
0.75
76
1.15
Linings (mm)
600mm max. cts
0.55
0.75
92
1.15
150
0.55
0.75
1.15
0.75
1.15
10
2.32
2.60
2.72
3.13
3.53
3.20
3.58
4.05
3.61
4.13
4.69
5.33
6.81
13
2.32
2.60
2.72
3.25
3.58
3.24
3.82
4.05
3.61
4.18
4.69
5.37
6.81
16
2.32
2.60
2.75
3.28
3.59
3.25
3.87
4.05
3.61
4.20
4.69
5.37
6.81
TABLE D2: mAximum WALL hEighT WiTh RONDO LiPPED STEEL STuDS NON-LOADBEARiNg WALLS
WALLS Of ShAfTS AND fiRE iSOLATED ExiTS (LOAD uDL = 0.35kPa)
Stud Size
Wall Frame and
Lining Configuration
51
BMT
0.5
64
0.75
0.5
0.75
76
1.15
Linings (mm)
600mm max. cts
0.55
0.75
92
1.15
150
0.55
0.75
1.15
0.75
1.15
10
2.07
2.34
2.34
2.80
3.15
2.76
3.20
3.62
3.06
3.70
3.81
3.81
3.81
13
2.07
2.34
2.34
2.80
3.17
2.76
3.37
3.62
3.06
3.70
4.20
4.83
5.53
16
2.07
2.34
2.34
2.90
3.18
2.76
3.41
3.62
3.06
3.70
4.20
4.83
5.53
NOTES:
Deflection Limit is span/240 to a maximum of 30mm, in accordance with BCA Specification C1.8.
Tabulated heights do not include axial loads (except self weight) or shelf loading.
Loadings: Table D1 Pultimate = 0.375 kPa, Pservice = 0.25 kPa.
Loadings: Table D2 Pultimate = 0.525 kPa, Pservice = 0.35 kPa.
Walls are not for external applications.
All loadings in accordance with AS1170:2002.
Walls analysed in accordance with AS4600:1996.
Noggings in accordance with Table D3.
Tables have been prepared by Rondo Building Services Pty Ltd.
Number of Noggings
(equally spaced)
0.0 - 3.0
3.0 - 6.0
6.0 - 8.0
D2
308 (16mm)
900
129 (28mm)
NOTES: Support clips include
direct fixing clips.
1200
Gyprock
Timber Grade
and Sheeting
Configuration
600mm cts.
F5
35
F8
45
35
F11
45
35
MGP 10
45
35
45
MGP 12
MGP 15
35
45
35
45
70
2.7
2.9
2.9
3.2
3.1
3.3
3.0
3.3
3.3
3.6
3.5
3.8
90
3.4
3.7
3.8
4.1
4.0
4.3
3.9
4.2
4.2
4.6
4.5
4.9
120
4.6
5.0
5.0
5.5
5.3
5.8
5.2
5.7
5.6
6.0
6.0
6.0
NOTES:
Stud heights have been determined based on a maximum deflection of H240 or 30mm maximum.
Noggings at 1350mm maximum centres, measured vertically.
Introduction
Gyprock plasterboard and CeminSeal Wallboard can
be used with masonry walls for effective fire and acoustic
solutions. These linings can eliminate the need for render,
increase the fire rating of the masonry, or provide an acoustic
performance to meet sound transmission and sound impact
ratings.
Systems incorporating masonry and an insulated cavity are
generally used where there is a requirement for excellent
acoustic performance and discontinuous construction. The
provision of a cavity also allows the inclusion of services.
Gyprock plasterboard may be directly applied to the
masonry substrate, screw fixed to metal furring channels
that are fixed to the masonry, or may be fixed to separate
stud framing. CeminSeal Wallboard may be fixed to furring
channels or studs.
Systems in this section are suitable for a wide range of
masonry products. These are typically clay and concrete
blocks, autoclaved aerated concrete blocks and panels, and
may include cast concrete elements. Minimum performance
conditions apply to the substrates to achieve the system
performance values, and these are stated in the system
specifications. Specific fixing details apply to each type of
substrate.
These wall systems are generally used in internal applications
in commercial, industrial, institutional, domestic and high-rise
domestic construction, or in the renovation of older buildings.
A number of systems for external masonry veneer walls can
be found in Section B and Section C.
Design
Considerations
Structural Performance
All wall elements must be designed for the applied loads.
Vertical loads may be supported by the masonry element
of the wall, or for non-fire rated walls, by the stud framing.
Lateral loads should be considered separately for framed
and masonry parts of a wall. To achieve the specified sound
performance, ties from masonry to the stud framing must
not be used.
framed Wall Elements
Guidance is given in Tables D1, D2, & D5 for the selection of
Rondo studs and for timber studs in non-loadbearing internal
walls only for 0.25kPa and 0.35kPa. For other brands of
studs, studs that are required to be loadbearing, and studs
subject to higher lateral pressures, contact the manufacturer
for design information. Maximum spans for Rondo furring
channels are given in Table D4.
Tall multi-residential buildings often have exterior operable
doors and windows, resulting in internal walls being subject
to wind pressure. In these cases, walls must be designed
for the appropriate loads.
Stud frames that are part of a masonry wall system may be
loadbearing. A qualified person must complete the structural
design of loadbearing wall systems. Walls with shelving
attached are considered loadbearing.
D3
fire Resistance
For systems without a stated Fire Resistance Level (FRL),
the system FRL is equal to the FRL of the masonry wall
element. The FRL of masonry walls is dependant on the
height and width of the wall; contact the manufacturer for
more information.
To achieve the required fire performance of a wall, it is
essential that installation is in accordance with the masonry
manufacturers details and relevant installation standards. This
should include fire sealing at the wall head and perimeters,
and filling of mortar joints. All gaps and penetrations should
be effectively fire sealed.
Vermiculite plaster has no capacity to accommodate building
movement and may not be suitable for use as a general
purpose fire rated caulking. Its use is specified in some wall/
ceiling junctions. Refer to the Gyprock Ceiling Systems
Installation Guide, NGYP570.
In systems with Gyprock Fyrchek plasterboard fixed to
furring channels, fixing, jointing and fire sealing must be
in accordance with Section B of this manual. FYRCHEK
plasterboard must be fully screw fixed, and Gyprock Acrylic
Stud Adhesive must not be relied on.
Acoustic Performance
The acoustic performance of some systems is dependant
on a minimum Rw of the masonry wall element. This is to
be the tested performance of the masonry without render
or sheet linings, and must be verified by the masonry unit
manufacturer.
Installation of the masonry element of the wall must be in
accordance with the manufacturers details for the tested
product.
Systems that meet the BCA requirements for discontinuous
construction are noted in the system specifications. These
have studs that are separated from the masonry by at least
12mm. The plasterboard lining on the studs (the wall leaf)
therefore has a separation of at least 12mm plus the depth
of the stud, which exceeds the BCA minimum of 20mm.
Ties between masonry and stud framing must not be used.
D4
Installation
masonry
framing
Components
Lining & fixing materials
Refer to Section A of this manual for detailed information
on Gyprock and Cemintel lining products, masonry
adhesive, and for fastener specifications for fixing GYPROCK
plasterboard to steel studs and furring channel.
framing
control Joints
Control joints must be installed to allow for structural
movement. Allowance for movement must be made through
the masonry and any direct fixed lining, and through framed
wall elements.
masonry
For systems in this section, masonry may include clay or
concrete blocks, autoclaved aerated concrete blocks and
panels, and reinforced concrete. Brick and block substrates
shall comply with AS3700.
D5
AcOuSTic
OPiNiON
PKA-053
Discontinuous
Construction
masonry
Wall
Requirements
SySTEm
N
cSR 737
56/46
57/47
1 x 13mm GYPROCK
plasterboard CD
57/47
58/48
55/45
56/46
100
128
56/48
58/50
1 x 13mm GYPROCK
plasterboard CD
57/49
59/51
55/47
57/49
107
135
1 x 13mm GYPROCK
plasterboard CD.
Refer to Masonry
Wall Manufacturer
for FRL Details
58/50
59/52
1 x 13mm GYPROCK
plasterboard CD
59/51
60/53
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
57/49
58/51
107
135
Masonry side
61/54
62/55
1 x 13mm GYPROCK
plasterboard CD
62/55
63/56
60/53
61/54
120
148
stud side
2 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
D6
Masonry side
stud side
cSR 762
Masonry side
stud side
cSR 761
Rw / Rw+ctr
1 x 6mm CeminSeal
Wallboard.
Tested
Brick,
Block or
concrete
Wall with Rw
> 41
92
Masonry side
stud side
cSR 760
64
AcOuSTic
OPiNiON
PKA-053
Discontinuous
Construction
masonry
Wall
Requirements
SySTEm
N
cSR 763
59/49
60/50
1 x 13mm GYPROCK
plasterboard CD
60/50
61/51
58/48
59/49
100
128
59/51
61/53
1 x 13mm GYPROCK
plasterboard CD
60/52
62/54
58/50
60/52
107
135
1 x 13mm GYPROCK
plasterboard CD.
Refer to Masonry
Wall Manufacturer
for FRL Details
61/53
62/55
1 x 13mm GYPROCK
plasterboard CD
62/54
63/56
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
60/52
61/54
107
135
Masonry side
64/57
65/58
1 x 13mm GYPROCK
plasterboard CD
65/58
66/59
63/56
64/57
120
148
stud side
2 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
Masonry side
stud side
cSR 766
Masonry side
stud side
cSR 765
Rw / Rw+ctr
1 x 6mm CeminSeal
Wallboard.
Tested
Brick,
Block or
concrete
Wall with Rw
> 44
92
Masonry side
stud side
cSR 764
64
D7
AcOuSTic
OPiNiON
PKA-053
Discontinuous
Construction
masonry
Wall
Requirements
SySTEm
N
cSR 738
61/51
62/53
1 x 13mm GYPROCK
plasterboard CD
62/52
63/54
60/50
61/52
100
128
60/51
62/54
1 x 13mm GYPROCK
plasterboard CD
61/52
63/55
59/50
61/53
104
132
1 x 10mm GYPROCK
plasterboard CD.
Refer to Masonry
Wall Manufacturer
for FRL Details
61/53
63/55
1 x 13mm GYPROCK
plasterboard CD
62/54
64/56
60/52
62/54
107
135
1 x 13mm GYPROCK
plasterboard CD.
63/55
64/57
1 x 13mm GYPROCK
plasterboard CD
64/56
65/58
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
62/54
63/56
107
135
Masonry side
66/59
67/60
1 x 13mm GYPROCK
plasterboard CD
67/60
68/61
65/58
66/59
120
148
stud side
2 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
D8
Masonry side
stud side
cSR 769
Masonry side
stud side
cSR 768
Masonry side
stud side
cSR 767
Rw / Rw+ctr
1 x 6mm CeminSeal
Wallboard.
Tested
Brick,
Block or
concrete
Wall with Rw
> 46
92
Masonry side
stud side
cSR 739
64
AcOuSTic
OPiNiON
PKA-053
Discontinuous
Construction
masonry
Wall
Requirements
SySTEm
N
cSR 774
61/46
Both sides
61/46
62/47
1 x 6mm CeminSeal
Wallboard.
58/43
59/44
164
220
59/45
60/47
Both sides
60/46
61/48
1 x 10mm GYPROCK
plasterboard CD.
57/43
58/45
172
228
60/47
62/49
Both sides
61/48
63/50
1 x 13mm GYPROCK
plasterboard CD.
58/45
60/47
178
234
62/49
63/50
63/50
64/51
60/47
61/48
178
234
cSR 780
cSR 781
Both sides
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
Rw / Rw+ctr
60/45
cSR 775
Refer to Masonry
Wall Manufacturer
for FRL Details
92
Tested
Brick,
Block or
concrete
Wall with Rw
> 41
64
D9
AcOuSTic
OPiNiON
PKA-053
Discontinuous
Construction
masonry
Wall
Requirements
SySTEm
N
cSR 776
63/48
Both sides
63/48
64/49
1 x 6mm CeminSeal
Wallboard.
60/45
61/46
164
220
62/48
63/50
Both sides
63/49
64/51
1 x 10mm GYPROCK
plasterboard CD.
60/46
61/48
172
228
63/50
64/51
Both sides
64/51
65/52
1 x 13mm GYPROCK
plasterboard CD.
61/48
62/49
178
234
64/51
66/53
65/52
67/54
62/49
64/51
178
234
cSR 783
cSR 784
Both sides
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
D10
Rw / Rw+ctr
62/47
cSR 777
Refer to Masonry
Wall Manufacturer
for FRL Details
92
Tested
Brick,
Block or
concrete
Wall with Rw
> 44
64
AcOuSTic
OPiNiON
PKA-053
Discontinuous
Construction
masonry
Wall
Requirements
SySTEm
N
cSR 778
66/51
Both sides
66/51
67/52
1 x 6mm CeminSeal
Wallboard.
63/48
64/49
164
220
64/50
66/53
Both sides
65/51
67/54
1 x 10mm GYPROCK
plasterboard CD.
62/48
64/51
172
228
65/52
67/54
Both sides
66/53
68/55
1 x 13mm GYPROCK
plasterboard CD.
63/50
65/52
178
234
67/54
68/55
68/55
69/56
65/52
66/53
178
234
cSR 787
cSR 788
Both sides
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
Rw / Rw+ctr
65/50
cSR 779
Refer to Masonry
Wall Manufacturer
for FRL Details
92
Tested
Brick,
Block or
concrete
Wall with Rw
> 46
64
D11
AcOuSTic
OPiNiON
PKA-053
Discontinuous
Construction
masonry
Wall
Requirements
WALL LiNiNgS
cSR 540
Both sides
Tested
Brick,
Block or
concrete
Wall with
Rw > 41
1 x 13mm
GYPROCK
plasterboard CD.
cSR 541
57/45
59/47
58/46
60/48
(c) TBL1025
55/43
57/45
142
170
59/47
60/49
60/48
61/50
(c) TBL1025
57/45
58/47
142
170
Both sides
1 x 13mm
GYPROCK
SOUNDCHEK
plasterboard.
cSR 542
Both sides
1 x 13mm
GYPROCK
plasterboard CD.
60/48
62/50
62/50
64/52
(c) TBL1025
58/46
60/48
142
170
Refer to
Masonry Wall
Manufacturer
for FRL Details
cSR 543
62/50
63/52
63/51
64/53
(c) TBL1025
60/48
61/50
142
170
Both sides
1 x 13mm
GYPROCK
SOUNDCHEK
plasterboard.
cSR 548
stud side
1 x 13mm
GYPROCK
plasterboard CD.
Furring side
1 x 6mm
CeminSeal
Wallboard.
D12
Rw / Rw+ctr
(Refer to Section A)
Tested
Brick,
Block or
concrete
Wall with
Rw > 44
92
(Refer to Section A)
Refer to
Masonry Wall
Manufacturer
for FRL Details
64
fuRRiNg cAViTy
iNfiLL
60/48
62/50
62/50
64/52
(c) TBL1025
58/46
60/48
135
163
AcOuSTic
OPiNiON
PKA-053
Discontinuous
Construction
masonry
Wall
Requirements
WALL LiNiNgS
cSR 549
Both sides
1 x 10mm
GYPROCK
plasterboard CD.
Both sides
Tested
Brick,
Block or
concrete
Wall with
Rw > 46
1 x 13mm
GYPROCK
plasterboard CD.
61/48
63/51
63/50
65/53
(c) TBL1025
59/46
61/49
136
164
62/50
64/52
63/51
65/53
(c) TBL1025
60/48
62/50
142
170
64/52
65/54
65/53
66/55
(c) TBL1025
62/50
63/52
142
170
Both sides
Refer to
Masonry Wall
Manufacturer
for FRL Details
1 x 13mm
GYPROCK
SOUNDCHEK
plasterboard.
cSR 551
stud side
1 x 13mm
GYPROCK
plasterboard CD.
Furring side
1 x 6mm
CeminSeal
Wallboard.
Rw / Rw+ctr
(Refer to Section A)
cSR 545
92
(Refer to Section A)
cSR 544
64
fuRRiNg cAViTy
iNfiLL
62/50
64/52
63/51
65/53
(c) TBL1025
60/48
62/50
135
163
D13
AcOuSTic
OPiNiON
PKA-053
NOT
Deemed
Discontinuous
Construction
masonry
Wall
Requirements
SySTEm
N
cSR 530
WALL LiNiNgS
Masonry side
1 x 13mm GYPROCK
plasterboard CD
Furring side
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
Tested
Brick,
Block or
concrete
Wall with Rw
> 41
Refer to Masonry
Wall Manufacturer
for FRL Details
cSR 531
Masonry side
1 x 13mm GYPROCK
plasterboard CD
Furring side
2 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
cSR 526
Masonry side
1 x 13mm GYPROCK
plasterboard CD
Furring side
1 x 9mm CeminSeal
Wallboard.
cSR 532
Masonry side
1 x 13mm GYPROCK
plasterboard CD
Furring side
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
Tested
Brick,
Block or
concrete
Wall with Rw
> 44
Refer to Masonry
Wall Manufacturer
for FRL Details
cSR 533
Masonry side
1 x 13mm GYPROCK
plasterboard CD
Furring side
2 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
cSR 527
Masonry side
1 x 13mm GYPROCK
plasterboard CD
Furring side
1 x 9mm CeminSeal
Wallboard.
D14
Rw / Rw+ctr
55/42
53/40
71
58/45
56/43
84
55/42
53/40
67
58/45
56/43
71
61/48
59/46
84
58/45
56/43
67
AcOuSTic
OPiNiON
PKA-053
NOT
Deemed
Discontinuous
Construction
masonry
Wall
Requirements
SySTEm
N
cSR 534
WALL LiNiNgS
Masonry side
1 x 13mm GYPROCK
plasterboard CD
Furring side
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
Tested
Brick,
Block or
concrete
Wall with Rw
> 46
Refer to Masonry
Wall Manufacturer
for FRL Details
cSR 535
Masonry side
1 x 13mm GYPROCK
plasterboard CD
Furring side
2 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
cSR 528
Masonry side
1 x 13mm GYPROCK
plasterboard CD
Furring side
1 x 9mm CeminSeal
Wallboard.
Rw / Rw+ctr
60/47
58/45
71
63/50
61/48
84
60/47
58/45
67
D15
AcOuSTic
TEST
OR
OPiNiON
ATf-1023
Discontinuous
Construction
fRL
Report/Opinion
SySTEm
N
WALL LiNiNgS
cAViTy iNfiLL
(Refer to Section A)
Rw / Rw+ctr
hEBEL 1030/1031
up to
/240/240
Both sides
64/59
1 x 10mm GYPROCK
plasterboard CD.
FCO 2073
WALL THICKNESS mm
SySTEm SPEcificATiON
200
AcOuSTic
TEST
OR
OPiNiON
2010861.1/
0505A/
R2/Vf
Discontinuous
Construction
fRL
Report/Opinion
SySTEm
N
WALL LiNiNgS
Rw / Rw+ctr
hEBEL 1000/1001
up to
/180/180
FCO 2073
Both sides
1 x 13mm GYPROCK
FYRCHEK plasterboard.
WALL THICKNESS mm
D16
62/54
200
AcOuSTic
TEST
OR
OPiNiON
2010861.1/
0505A/
R2/Vf
Discontinuous
Construction
fRL
Report/Opinion
SySTEm
N
WALL LiNiNgS
Rw / Rw+ctr
hEBEL 1006/1007
up to
/180/180
Both sides
62/51
1 x 13mm GYPROCK
FYRCHEK plasterboard
FCO 2073
WALL THICKNESS mm
SySTEm SPEcificATiON
228
AcOuSTic
TEST
OR
OPiNiON
Discontinuous
Construction
fRL
Report/Opinion
SySTEm
N
WALL LiNiNgS
cAViTy iNfiLL
(Refer to Section A)
Rw / Rw+ctr
hEBEL 1032/1033
up to
/240/240
FCO 2073
Both sides
1 x 10mm GYPROCK
plasterboard CD.
WALL THICKNESS mm
64/59
256
D17
AcOuSTic
OPiNiON
PKA-A073
Discontinuous
Construction
fRL
Report/Opinion
SySTEm
N
hEBEL 1302
Both sides
1 x 10mm GYPROCK
plasterboard CD.
Both sides
1 x 13mm GYPROCK
plasterboard CD.
Both sides
/90/90
90/90/90
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
WFRA 45771-3
49/38
61/48
63/51
56/43
59/47
255
295
(a) Nil
49/38
50/39
63/51
64/52
58/46
60/48
261
301
(a) Nil
52/41
53/42
66/54
67/56
61/49
63/52
261
301
(a) Nil
48/37
50/39
62/49
63/51
57/44
59/47
255
295
(a) Nil
50/39
51/40
65/52
66/55
60/47
62/51
253
293
hEBEL 1305
Both sides
1 x 10mm GYPROCK
AQUACHEK
plasterboard.
hEBEL 1306
Both sides
1 x 9mm CeminSeal
Wallboard.
D18
Rw / Rw+ctr
47/36
hEBEL 1304
90
(a) Nil
hEBEL 1303
70
AcOuSTic
TEST
OR
OPiNiON
N/A
fRL
Report/Opinion
SySTEm
N
WALL LiNiNgS
ADDiTiONAL fRL
cSR 730
Both sides
1 x 16mm GYPROCK
FYRCHEK plasterboard
cSR 731
masonry
Wall
Both sides
2 x 13mm GYPROCK
FYRCHEK plasterboard.
x/y/Z
FCO 382
cSR 732
Both sides
2 x 16mm GYPROCK
FYRCHEK plasterboard.
D19
AcOuSTic
TEST
OR
OPiNiON
N/A
fRL
Report/Opinion
SySTEm
N
WALL LiNiNgS
ADDiTiONAL fRL
Lining on fire side
cSR 722
one side
1 x 16mm GYPROCK
FYRCHEK plasterboard
cSR 723
masonry
Wall
one side
2 x 13mm GYPROCK
FYRCHEK plasterboard.
x/y/Z
FCO 382
cSR 724
one side
2 x 16mm GYPROCK
FYRCHEK plasterboard.
D20
SySTEm
N
FCO 1356
PLASTERBOARD
LiNiNg
Steel reinforced
concrete column
cSR 795
1 x 16mm
GYPROCK
FYRCHEK
plasterboard.
x+30/ /
cSR 796
2 x 13mm
GYPROCK
FYRCHEK
plasterboard.
x+60/ /
2 x 16mm
GYPROCK
FYRCHEK
plasterboard.
cSR 798
1 x 25mm
GYPROCK
SHAFT LINER
PANEL.
x+120/ /
Steel reinforced
concrete column
Furring Channel
N308 or Centre
Fix Batten N333
at 600mm max.
centres
50mm
600mm max.
max.
Anchor Clip N237 fixed with metal fasteners at 100mm max.
from each end and 1200mm max. centres along column
cSR 797
x+120/ /
GYPROCK
FYRCHEK
plasterboard fixed
at 200mm
maximum centres
to all framing
Direct fasten
each layer of
GYPROCK
FYRCHEK
plasterboard with
Tapcon 10g
screws (or
equivalent) at 400
x 400mm max.
horizontal and
vertical centres
200mm max.
Apply
External
Angle
Bead to
all
corners
and set
Note: Butt joints in single layer systems to be
backed by furring channel or nogging
75mm
max.
400mm max.
D21
fig D4: iNSTALLATiON DETAiL mASONRy WALL (ExcEPT AAc) VERTicAL ShEETiNg ADhESiVE fixiNg
For additional information, refer to GYP547, Gyprock Residential Installation Guide
Adhesive daubs
50mm max.
from sheet
edge
Adhesive daubs
at 230mm max.
centres
Adhesive daubs
100mm max from
top edge of sheet
Adhesive daubs
50mm max.
from sheet
edge
NON-fiRE RATED
fiRE RATED
fixing Specifications
Adhesive
Adhesive daubs
at 460mm max.
centres
Adhesive
daubs
at 460mm
max.
centres
GYPROCK
Plasterboard
Adhesive daubs
100mm max from
bottom edge of
sheet
Refer to Section A
Location
Field
Adhesive at 460mm
max. centres
beginning 100mm
max. from top and
bottom sheet edges
and 50mm max.
from recessed sheet
edges
Butt Joints,
Corners &
Openings
Adhesive at 460mm
max. centres 50mm
max. from sheet
edges
NON-fiRE RATED
fiRE RATED
300mm min.
300mm
max.
CSR Gyprock
Resilient Mounts or
Furring Anchor Clips
at 1200mm max.
from tracks and
1200mm max.
centres between
600mm
min
600mm
min
600mm
max.
300mm
max.
Rondo Furring
Channel at 600mm
maximum
horizontal centres
Caulk all perimeter
gaps with CSR
Gyprock Fire Mastic
to achieve stated fire
rated and acoustic
performance
Rondo Track or
Angle fixed to floor
D22
fixing Specifications
Screws
Refer to Section A
1st Layer
Edges &
Field
Screws at 600mm
max. centres
2nd Layer
Field
Screws at 300mm
max. centres
Recessed
Edges
Screw at
each furring
Butt
Joints
Screws at
200mm max. centres
Angles &
Openings
Screws at
300mm max. centres
NOTE:
Single layer systems using fire
rated or non-fire rated Gyprock
plasterboard are fixed to the same
specifications as detailed for the 2nd
layer.
200mm
max.
Fasteners at 10 to 16mm
from sheet edges
fig D6: iNSTALLATiON DETAiL hEBEL AAc WALL VERTicAL ShEETiNg ScREW fixiNg
For additional information, refer to CSR Hebel Design Guide Acoustic Wall Systems
NON-fiRE RATED
fiRE RATED
10-16mm
max.
fixing Specifications
GYPROCK
Plasterboard
Fixings
Location
Field, Butt
Joints &
Edges
Screws at 600mm
max. horizontal
centres x 300mm
max. vertical centres
6mm min.
gap
600 mm
max.
fig D7: iNSTALLATiON DETAiL hEBEL AAc WALL hORiZONTAL ShEETiNg ScREW fixiNg
For additional information, refer to CSR Hebel Design Guide Acoustic Wall Systems
NON-fiRE RATED
fiRE RATED
fixing Specifications
CSR Hebel AAC Panel
Fixings
Location
Field, Butt
Joints &
Edges
Screws at 600mm
max. horizontal
centres x 300mm
max. vertical centres
GYPROCK
Plasterboard
300mm
max.
6mm min.
gap
10-16mm
min. from
each edge
600mm
max.
D23
Notes
D24
Section E
Ceiling Systems
Contents
Introduction
E2
Design Considerations
E2 E3
Installation
E4
Components
E4 E5
System Specifications
loor/Ceiling Systems
F
(Timber Flooring)
E6 E15
loor/Ceiling Systems
F
(Concrete Flooring)
E16 E23
oof/Ceiling Systems
R
(Pitched Roofing)
E24 E29
oof/Ceiling Systems
R
(Steel Sheet Roofing)
E30 E33
eiling Systems
C
Fire Rated from Above
E34
E35
E36
E37 E38
E39 E43
E1
Introduction
CSR has developed a wide range of floor/ceiling and
roof/ceiling systems to meet specific fire and acoustic
requirements. The systems include ratings for sound
transmission, sound impact and sound absorption, for fire
resistance up to FRL 120/120/120, and for up to 60 minutes
Resistance to Incipient Spread of Fire (RISF).
Generally, the fire resistance of floor and roof/ceiling systems
is assessed from below, in accordance with the standard
fire test of AS1530.4. This is the requirement of the BCA
where lightweight construction is used for compartmentation
and separation. Some elements such as fire-isolated
passageways are required to have an FRL when tested from
outside. A number of ceiling systems are available that offer
fire resistance from above to meet this requirement.
CSR ceiling systems use various fixing techniques for the
attachment of linings. These include:
a) Direct fixing to timber and steel joists or truss bottom
chords.
b) Screw fixing to steel furring channels.
c) Screw fixing to resilient or resiliently mounted furring
channels.
d) Screw fixing to suspended concealed metal grid.
e) Lay-in tiles in suspended exposed metal grid or Fricker
Easy Access System.
Design
Considerations
Structural
All floor, roof and ceiling framing must be designed for
the applied loads. Guidance for the selection of Rondo
suspension and grid components is given in brochure
NGYP570 Gyprock Ceiling Systems Installation Guide.
For other elements, refer to the appropriate design standards
or handbooks, or contact the manufacturer for design
information.
CSR recommends a minimum design pressure of 0.25kPa
(downward) for the ceiling framing. Other wind pressures may
be applicable; the designer should refer to AS/NZS1170.
Wind loads on external ceilings can be similar to those on
adjacent walls. Pressures can be positive or negative and
the lining, grid and structure should be designed to resist
the loads. Internal suspension components, even with down
struts, may not be suitable.
Fire Performance
Gyprock fire rated ceiling systems have been designed with
fire protection that protects the framing. This means that no
consideration of steel or timber framing design need be given
for the fire rating.
E2
Acoustic Performance
Sound Transmission
Sound flanking, the effectiveness of workmanship and
caulking, the presence and treatment of penetrations, and
the inclusion of structural elements and bridging items, may
affect the acoustic performance of ceiling systems. Refer to
Section A for detailed information.
Alternative structural framing systems including steel, and
composite steel/timber joists, laminated timber joists, and
trussed or plywood web joists may be used without reducing
the system rating. The stated or implied minimum cavity
depth must also be maintained.
For effective control of sound in the flanking path of a floor
or roof space, acoustically rated walls should continue to
the underside of the floor or roof above. Alternatively, select
a detail from section G equivalent to the required Rw or
Rw + Ctr performance of the wall.
Ceilings systems beneath concrete slabs are unlikely to
achieve greater than DnT,w 65 due to the number of flanking
paths and variations in building construction.
Rw and Rw+Ctr values published are estimated performance
in a laboratory, and the higher values may be beyond the
limits of some laboratories to measure.
In non-fire rated systems, to attain the stated sound
transmission performance, use a tested acoustic sealant.
All penetrations should be treated to maintain the acoustic
integrity of the system.
The values given for roofs assume that there are no vents,
skylights or similar penetrations, and that the eaves are not
vented. Note that the effect of such penetrations will be lower
for ceilings lined with multiple layers of plasterboard.
Sound impact performance is stated as Ln,w + CI. Note that
a lower value of Ln,w + CI has a higher impact performance.
Values refer to expected laboratory performance, and
assume relatively stiff floor joists. Installations with joists of
lower stiffness may reduce the impact performance.
Floors finished with carpet and underlay achieve better
impact performance than those with hard surfaces such as
floorboards and tiles. If carpet is subsequently removed (from
a system that uses it in its performance value), the floor may
no longer meet the BCA impact requirements.
Sound Absorption
Gyprock Perforated Plasterboard, Ecophon, Fricker and
USG ceiling products have sound absorption qualities. These
products may be used to influence the reverberation time of
a room in order to improve the sound quality.
Product performance is expressed as NRC, and values vary
from 0 (total reflection) to 1.00 (total absorption). NRC values
can be found in system CSR 890
E3
Jointing
24mm
4.5mm
Gyprock
Resilient
Mount
20mm
Components
Furring Channel
N129 or N308
40mm (N129)
28mm (N308)
Installation
GYPROCK Plasterboard
Control Joints
Control joints are used to reduce the possibility of cracks
forming from structural movement, thermal and moisture
movement and the like. Locations for joints should be chosen
by the designer with regard to building shape, structural
breaks, changes of substrate, and joint appearance.
Gyprock
Resilient
Mount
NOTE: For fire rated systems with single layer lining fixed
direct to joists, no control joint detail is available. Use a
double layer system or furring channels where control joints
are required.
Suspended Ceilings
For detailed information on installation and maintenance of
suspension systems, contact CSR Fricker Comprador on
1300 374 253.
E4
Resilient Mount to
Top Cross Rail Clip
Gyprock Screw
Furring Channel
Other
Sarking with mass at least 350g/m2 is specified in some
roof/ceiling systems to achieve the acoustic value. Suitable
products are Bradford Thermofoil 733 and Thermotuff SS.
1200mm
80mm
1040mm
440mm
160mm
1200mm
3600mm
440mm
Overall 3600mm
GYPROCK/CEMINTEL Product
General Applications
Thickness
(mm)
(mm)
350
NA
450
NA
450
450
600
450
600
450
600
NA
16mm FYRCHEK
600
450
TABLe e2: MAXiMuM SPAnS FOR MeTAL BATTen/FuRRinG CHAnneL uSeD in CeiLinGS
Gyprock Plasterboard
Layers x Thickness
N581*
N308*
N129*
Resilient Furring
Furring Channel
Furring Channel
Spacing of Furring
Spacing of Furring
450
600
600
600
450
600
Spacing of Furring
450
600
1000
900
1550
1400
600
1000
1550
1 x 10mm SUPERCHEK
600
600
1100
1000
1550
1400
1 x 16mm FYRCHEK
600
600
1100
1050
1550
1400
2 x 13/16mm FYRCHEK
600
600
1100
900
1400
1300
900
800
1300
1200
3 x 16 FYRCHEK
NOTE: Furring to be continuous over 2 or more spans. Dead load deflection Span360. * Includes Internal UDL of 0.25kPa.
E5
Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
FRL
Report/Opinion
SYSTeM
n
CeiLinG LininGS
Rw / Rw+Ctr
Bare Floor
Ln,w+Ci
Carpet +
underlay
Ln,w+Ci
(a) Nil
40/34
80-85
60-65
43/36
80-85
60-62
43/36
80-85
60-62
(a) Nil
39/32
60 65
42/34
60 65
42/34
60 65
(a) Nil
37/30
60 65
40/32
60 65
40/32
60 65
(a) Nil
43/37
55 60
46/39
80 85
55 60
46/39
80 85
55 60
CAViTY inFiLL
(Refer to Section A)
CSR 799
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
//
CSR 801
1 x 13mm GYPROCK
Plasterboard CD.
//
CSR 803
1 x 10mm GYPROCK
SUPACEIL
plasterboard.
//
CSR 804
//
E6
2 x 10mm GYPROCK
SUPERCHEK.
Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
FRL
Report/Opinion
SYSTeM
n
CeiLinG LininGS
Rw / Rw+Ctr
Bare Floor
Ln,w+Ci
Carpet +
underlay
Ln,w+Ci
(a) Nil
40/34
55 60
43/36
55 60
43/36
55 60
(a) Nil
40/34
55 60
43/36
55 60
43/36
55 60
(a) Nil
43/37
55 60
46/39
80 85
55 60
46/39
80 85
55 60
(a) Nil
43/37
55 60
46/39
80 85
55 60
46/39
80 85
55 60
(a) Nil
42/36
55 60
45/38
80 85
55 60
45/38
80 85
55 60
(a) Nil
45/39
80 85
50 55
48/41
80 85
50 55
48/41
80 85
50 55
CAViTY inFiLL
(Refer to Section A)
CSR 805
1 x 13mm GYPROCK
FYRCHEK
Plasterboard.
30/30/30
EWFA 26162
NOTE: Framing at
450mm max. centres.
CSR 820
1 x 16mm GYPROCK
FYRCHEK
Plasterboard.
30/30/30
EWFA 26162
CSR 806
60/60/60
2 x 13mm GYPROCK
FYRCHEK
Plasterboard.
+RISF 30
minutes
EWFA 26162
CSR 809
60/60/60
+RISF 60
minutes
EWFA 26162
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).
CSR 807
90/90/90
2 x 16mm GYPROCK
FYRCHEK
Plasterboard.
+RISF 60
minutes
EWFA 26162
CSR 808
120/120/120
+RISF 60
minutes
EWFA 26162
3 x 16mm GYPROCK
FYRCHEK
Plasterboard.
E7
Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
FRL
Report/Opinion
SYSTeM
n
CeiLinG LininGS
Rw / Rw+Ctr
Bare Floor
Ln,w+Ci
Carpet +
underlay
Ln,w+Ci
(a) Nil
39/32
60 65
44/35
60 65
44/35
60 65
(a) Nil
39/32
80-85
60-65
44/37
75-80
60-62
44/37
75-80
60-62
(a) Nil
42/36
80-85
60-62
47/41
75-80
55-60
47/41
75-80
55-60
(a) Nil
40/34
80-85
60-62
45/39
75-80
55-60
45/39
75-80
55-60
(a) Nil
41/34
55 60
46/37
80 85
55 60
46/37
80 85
55 60
(a) Nil
45/39
75-80
55-60
50/44
70-75
50-55
50/44
70-75
50-55
CAViTY inFiLL
(Refer to Section A)
CSR 810
1 x 10mm GYPROCK
SUPACEIL
plasterboard.
//
CSR 886
1 x 10mm GYPROCK
Plasterboard CD.
//
CSR 885
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
//
CSR 811
1 x 13mm GYPROCK
Plasterboard CD.
//
CSR 812
1 x 6mm CeminSeal
Wallboard.
//
CSR 888
//
E8
2 x 10mm GYPROCK
SUPERCHEK
plasterboard.
Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
SYSTeM
n
CSR 815
30/30/30
CeiLinG LininGS
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
Furring channel at
450mm maximum
centres.
EWFA 26162
Rw / Rw+Ctr
Bare Floor
Ln,w+Ci
Carpet +
underlay
Ln,w+Ci
(a) Nil
42/36
55 60
47/39
80 85
55 60
47/39
80 85
55 60
(a) Nil
42/36
55 60
47/39
80 85
55 60
47/39
80 85
55 60
(a) Nil
45/39
80 85
55 60
50/42
75 80
55 60
50/42
75 80
55 60
(a) Nil
45/39
80 85
55 60
50/42
75 80
55 60
50/42
75 80
55 60
(a) Nil
44/38
80 85
55 60
49/41
80 85
55 60
49/41
80 85
55 60
(a) Nil
47/41
80 85
55 60
52/44
75 80
55 60
52/44
75 80
55 60
CAViTY inFiLL
(Refer to Section A)
CSR 816
1 x 16mm GYPROCK
FYRCHEK
plasterboard.
30/30/30
EWFA 26162
CSR 814
60/60/60
2 x 13mm GYPROCK
FYRCHEK
plasterboard.
+RISF 30
minutes
EWFA 26162
CSR 819
60/60/60
+RISF 60
minutes
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).
EWFA 26162
CSR 817
90/90/90
2 x 16mm GYPROCK
FYRCHEK
plasterboard.
+RISF 60
minutes
EWFA 26162
CSR 818
120/120/120
+RISF 60
minutes
EWFA 26162
3 x 16mm GYPROCK
FYRCHEK
plasterboard.
E9
Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
SYSTeM
n
CeiLinG LininGS
Rw / Rw+Ctr
Bare Floor
Ln,w+Ci
Carpet +
underlay
Ln,w+Ci
(a) Nil
46/37
75 80
55 60
55/46
65 70
50 55
54/44
65 70
50 55
(a) Nil
46/40
75 80
55 60
55/47
65 70
50 55
54/45
65 70
50 55
(a) Nil
49/43
75 80
55 60
58/50
65 70
50 55
57/48
65 70
50 55
CAViTY inFiLL
(Refer to Section A)
CSR 821
1 x 13mm GYPROCK
Plasterboard CD.
//
CSR 823
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
//
CSR 824
//
E10
2 x 10mm GYPROCK
SUPERCHEK
plasterboard.
Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
SYSTeM
n
CSR 825
30/30/30
CeiLinG LininGS
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
Furring channel at
450mm maximum
centres.
EWFA 26162
Rw / Rw+Ctr
Bare Floor
Ln,w+Ci
Carpet +
underlay
Ln,w+Ci
(a) Nil
47/41
75 80
55 60
56/48
65 70
50 55
55/46
65 70
50 55
(a) Nil
46/40
75 80
55 60
55/47
65 70
50 55
54/45
70 75
50 55
(a) Nil
50/44
70 75
50 55
59/51
60 62
45 50
58/48
60 62
45 50
(a) Nil
50/44
70 75
50 55
59/51
60 65
45 50
58/48
60 65
45 50
(a) Nil
50/44
70 75
50 55
59/51
60 62
45 50
58/48
60 62
45 50
(a) Nil
49/43
70-75
35-40
59/53
60-62
35-40
59/52
60-62
35-40
CAViTY inFiLL
(Refer to Section A)
CSR 826
1 x 16mm GYPROCK
FYRCHEK
plasterboard.
30/30/30
EWFA 26162
CSR 829
60/60/60
+RISF 60
minutes
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).
EWFA 26162
CSR 822
60/60/60
2 x 13mm GYPROCK
FYRCHEK
plasterboard.
+RISF 30
minutes
EWFA 26162
CSR 827
90/90/90
2 x 16mm GYPROCK
FYRCHEK
plasterboard.
+RISF 60
minutes
EWFA 26162
CSR 828
120/120/120
+RISF 60
minutes
EWFA 26162
3 x 16mm GYPROCK
FYRCHEK
plasterboard.
E11
Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
FRL
Report/Opinion
SYSTeM
n
CeiLinG LininGS
Rw / Rw+Ctr
Bare Floor
Ln,w+Ci
Carpet +
underlay
Ln,w+Ci
(a) Nil
46/39
80 85
60 65
52/45
75 80
55 60
52/45
75 80
55 60
(a) Nil
46/40
80 85
60 65
52/46
75 80
55 60
52/46
75 80
55 60
(a) Nil
48/42
80 85
60 65
54/48
75 80
55 60
54/48
75 80
55 60
56/50
70 75
55 60
(a) Nil
49/43
80 85
60 65
54/49
75 80
55 60
54/49
75 80
55 60
56/51
70 75
55 60
CAViTY inFiLL
(Refer to Section A)
CSR 831
1 x 13mm GYPROCK
Plasterboard CD.
//
CSR 833
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
//
CSR 832
2 x 13mm GYPROCK
Plasterboard CD.
//
CSR 834
//
E12
2 x 10mm GYPROCK
SUPERCHEK
plasterboard.
Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
SYSTeM
n
CeiLinG LininGS
Rw / Rw+Ctr
Bare Floor
Ln,w+Ci
Carpet +
underlay
Ln,w+Ci
(a) Nil
46/40
80 85
60 65
52/46
75 80
55 60
52/46
75 80
55 60
(a) Nil
49/43
80 - 85
55 - 60
55/49
70 - 75
50 - 55
55/49
70 - 75
50 - 55
(a) Nil
50/44
75 80
55 60
56/50
70 75
50 55
56/50
70 75
50 55
58/52
70 75
50 55
(a) Nil
49/43
80 85
55 60
55/49
70 75
50 55
55/49
70 75
50 55
57/51
70 75
50 55
(a) Nil
52/46
75 80
55 60
58/52
70 75
50 55
58/52
70 75
50 55
60/54
65 70
50 55
CAViTY inFiLL
(Refer to Section A)
CSR 835
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
30/30/30
EWFA 26162
Furring channel at
450mm maximum
centres.
CSR 836
60/60/60
2 x 13mm GYPROCK
FYRCHEK
plasterboard.
+RISF 30
minutes
EWFA 26162
CSR 839
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
60/60/60
+RISF 60
minutes
EWFA 26162
1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).
CSR 837
90/90/90
2 x 16mm GYPROCK
FYRCHEK
plasterboard.
+RISF 60
minutes
EWFA 26162
CSR 838
120/120/120
+RISF 60
minutes
EWFA 26162
3 x 16mm GYPROCK
FYRCHEK
plasterboard.
E13
Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
SYSTeM
n
CeiLinG LininGS
Rw / Rw+Ctr
Bare Floor
Ln,w+Ci
Carpet +
underlay
Ln,w+Ci
(a) Nil
48/41
75 80
55 60
54/47
70 75
50 55
54/47
70 75
50 55
56/49
65 70
50 55
(a) Nil
48/42
75 80
55 60
54/48
70 75
50 55
54/48
70 75
50 55
56/50
65 70
50 55
(a) Nil
51/45
70 - 75
50 - 55
57/51
60 - 62
45 - 50
57/51
60 - 62
45 - 50
CAViTY inFiLL
(Refer to Section A)
CSR 841
1 x 13mm GYPROCK
Plasterboard CD.
//
CSR 845
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
30/30/30
EWFA 26162
Furring channels at
450mm maximum
centres.
CSR 846
60/60/60
+RISF 30
minutes
EWFA 26162
E14
2 x 13mm GYPROCK
FYRCHEK
plasterboard.
Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
SYSTeM
n
CeiLinG LininGS
Rw / Rw+Ctr
Bare Floor
Ln,w+Ci
Carpet +
underlay
Ln,w+Ci
(a) Nil
52/46
70 75
50 55
58/52
60 62
45 50
58/52
60 62
45 50
60/54
60 62
40 45
(a) Nil
51/45
70 75
50 55
57/51
60 62
45 50
57/51
60 62
45 50
59/53
60 62
45 50
(a) Nil
54/48
70 75
45 50
60/54
60 62
40 45
60/54
60 62
40 45
62/56
60 62
40 45
CAViTY inFiLL
(Refer to Section A)
CSR 849
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
60/60/60
+RISF 60
minutes
EWFA 26162
1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).
CSR 847
90/90/90
2 x 16mm GYPROCK
FYRCHEK
plasterboard.
+RISF 60
minutes
EWFA 26162
CSR 848
120/120/120
+RISF 60
minutes
EWFA 26162
3 x 16mm GYPROCK
FYRCHEK
plasterboard.
E15
Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
FRL
Report/Opinion
SYSTeM
n
CeiLinG LininGS
Rw / Rw+Ctr
Bare Floor
Ln,w+Ci
Carpet +
underlay
Ln,w+Ci
(a) Nil
56/46
70-75
35-40
60/50
65-70
35-40
59/49
65-70
35-40
(a) Nil
57/47
70-75
35-40
61/53
65-70
35-40
60/52
65-70
35-40
(a) Nil
56/46
70-75
35-40
60/50
65-70
35-40
59/49
65-70
35-40
(a) Nil
58/49
65-70
35-40
62/54
65-70
35-40
61/53
65-70
35-40
(a) Nil
59/50
65-70
35-40
64/56
60-65
35-40
63/55
60-65
35-40
(a) Nil
60/52
65-70
35-40
65/57
60-65
35-40
64/56
60-65
35-40
CAViTY inFiLL
(Refer to Section A)
CSR 257
Refer to
AS3600
1 x 10mm GYPROCK
Plasterboard CD.
CSR 258
Refer to
AS3600
1 x 13mm GYPROCK
Plasterboard CD.
CSR 259
1 x 10mm GYPROCK
SUPACEIL
plasterboard.
Refer to
AS3600
CSR 260
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
Refer to
AS3600
CSR 261
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
Refer to
AS3600
CSR 262
Refer to
AS3600
E16
2 x 10mm GYPROCK
SUPERCHEK.
Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
FRL
Report/Opinion
SYSTeM
n
CSR 263
30/30/30
EWFA 26162
CeiLinG LininGS
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
Furring channel at
450mm maximum
centres.
Rw / Rw+Ctr
Bare Floor
Ln,w+Ci
Carpet +
underlay
Ln,w+Ci
(a) Nil
58/49
65-70
35-40
63/55
65-70
35-40
62/54
65-70
35-40
(a) Nil
59/50
65-70
35-40
62/54
60-65
40-45
61/53
60-65
40-45
(a) Nil
61/53
65-70
35-40
66/58
60-65
35-40
65/57
60-65
35-40
(a) Nil
62/54
65-70
35-40
66/58
60-65
35-40
65/57
60-65
35-40
(a) Nil
63/56
65-70
35-40
68/61
60-65
35-40
67/60
60-65
35-40
CAViTY inFiLL
(Refer to Section A)
CSR 264
60/60/60
2 x 13mm GYPROCK
FYRCHEK
plasterboard.
+RISF 30
minutes
EWFA 26162
CSR 265
60/60/60
+RISF 60
minutes
EWFA 26162
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).
CSR 266
90/90/90
2 x 16mm GYPROCK
FYRCHEK
plasterboard.
+RISF 60
minutes
EWFA 26162
CSR 267
120/120/120
+RISF 60
minutes
EWFA 26162
3 x 16mm GYPROCK
FYRCHEK
plasterboard.
E17
Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
FRL
Report/Opinion
SYSTeM
n
CeiLinG LininGS
Rw / Rw+Ctr
Bare Floor
Ln,w+Ci
Carpet +
underlay
Ln,w+Ci
(a) Nil
57/47
70-75
40-45
61/51
65-70
40-45
60/50
65-70
40-45
(a) Nil
58/48
65-70
40-45
62/54
60-62
40-45
61/53
60-62
40-45
(a) Nil
57/47
70-75
40-45
61/51
65-70
40-45
60/50
65-70
40-45
(a) Nil
59/50
62-66
40-45
63/55
60-62
40-45
62/54
60-62
40-45
(a) Nil
60/51
62-66
40-45
65/56
60-62
40-45
64/55
60-62
40-45
(a) Nil
61/53
62-66
40-45
66/58
55-60
40-45
65/57
55-60
40-45
CAViTY inFiLL
(Refer to Section A)
CSR 337
Refer to
AS3600
1 x 10mm GYPROCK
Plasterboard CD.
CSR 959
Refer to
AS3600
1 x 13mm GYPROCK
Plasterboard CD.
CSR 339
1 x 10mm GYPROCK
SUPACEIL
plasterboard.
Refer to
AS3600
CSR 340
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
Refer to
AS3600
CSR 341
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
Refer to
AS3600
CSR 342
Refer to
AS3600
E18
2 x 10mm GYPROCK
SUPERCHEK.
Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
FRL
Report/Opinion
SYSTeM
n
CSR 343
30/30/30
EWFA 26162
CeiLinG LininGS
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
Furring channel at
450mm maximum
centres.
Rw / Rw+Ctr
Bare Floor
Ln,w+Ci
Carpet +
underlay
Ln,w+Ci
(a) Nil
59/50
62-66
40-45
64/55
58-62
40-45
63/54
58-62
40-45
(a) Nil
60/52
62-66
40-45
67/59
55-60
40-45
66/58
55-60
40-45
(a) Nil
62/54
60-64
40-45
67/59
55-60
40-45
66/58
55-60
40-45
(a) Nil
63/55
60-64
40-45
66/58
55-60
40-45
65/57
55-60
40-45
(a) Nil
64/57
60-62
40-45
68/61
55-60
40-45
68/61
55-60
40-45
CAViTY inFiLL
(Refer to Section A)
CSR 344
60/60/60
2 x 13mm GYPROCK
FYRCHEK
plasterboard.
+RISF 30
minutes
EWFA 26162
CSR 345
60/60/60
+RISF 60
minutes
EWFA 26162
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).
CSR 346
90/90/90
2 x 16mm GYPROCK
FYRCHEK
plasterboard.
+RISF 60
minutes
EWFA 26162
CSR 347
120/120/120
+RISF 60
minutes
EWFA 26162
3 x 16mm GYPROCK
FYRCHEK
plasterboard.
E19
Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
FRL
Report/Opinion
SYSTeM
n
CeiLinG LininGS
CSR 457
Refer to
AS3600
1 x 10mm GYPROCK
Plasterboard CD.
CSR 458
Refer to
AS3600
1 x 13mm GYPROCK
Plasterboard CD.
CSR 459
1 x 10mm GYPROCK
SUPACEIL
plasterboard.
Refer to
AS3600
CSR 460
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
Refer to
AS3600
CSR 461
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
Refer to
AS3600
CSR 462
Refer to
AS3600
E20
2 x 10mm GYPROCK
SUPERCHEK.
Rw / Rw+Ctr
Bare Floor
Ln,w+Ci
Carpet +
underlay
Ln,w+Ci
(a) Nil
60/53
65-70
40-45
65/58
60-65
40-45
66/59
60-65
40-45
65/58
60-65
40-45
(a) Nil
61/54
65-70
40-45
66/59
60-65
40-45
67/60
60-65
40-45
66/59
60-65
40-45
(a) Nil
60/53
65-70
40-45
65/58
60-65
40-45
66/59
60-65
40-45
65/58
60-65
40-45
(a) Nil
62/55
65-70
40-45
67/60
60-65
40-45
68/61
60-65
40-45
67/60
60-65
40-45
(a) Nil
63/56
60-65
40-45
68/61
55-60
40-45
69/62
55-60
40-45
68/61
55-60
40-45
(a) Nil
65/58
60-65
40-45
70/63
55-60
40-45
71/64
55-60
40-45
70/63
55-60
40-45
CAViTY inFiLL
(Refer to Section A)
Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
FRL
Report/Opinion
SYSTeM
n
CSR 463
30/30/30
EWFA 26162
CeiLinG LininGS
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
Furring channel at
450mm maximum
centres.
CSR 464
60/60/60
2 x 13mm GYPROCK
FYRCHEK
plasterboard.
+RISF 30
minutes
EWFA 26162
CSR 465
60/60/60
+RISF 60
minutes
EWFA 26162
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).
CSR 466
90/90/90
2 x 16mm GYPROCK
FYRCHEK
plasterboard.
+RISF 60
minutes
EWFA 26162
CSR 467
120/120/120
+RISF 60
minutes
EWFA 26162
3 x 16mm GYPROCK
FYRCHEK
plasterboard.
Rw / Rw+Ctr
Bare Floor
Ln,w+Ci
Carpet +
underlay
Ln,w+Ci
(a) Nil
62/55
60-65
40-45
67/60
55-60
40-45
68/61
55-60
40-45
67/60
55-60
40-45
(a) Nil
65/58
60-62
40-45
70/63
55-60
40-45
71/64
55-60
40-45
70/63
55-60
40-45
(a) Nil
67/61
60-65
40-45
72/66
55-60
40-45
73/67
55-60
40-45
72/66
55-60
40-45
(a) Nil
67/61
60-65
40-45
72/66
55-60
40-45
73/67
55-60
40-45
72/66
55-60
40-45
(a) Nil
69/63
55-60
40-45
74/68
50-55
40-45
75/69
50-55
40-45
74/68
50-55
40-45
CAViTY inFiLL
(Refer to Section A)
E21
Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
FRL
Report/Opinion
SYSTeM
n
CeiLinG LininGS
CSR 557
Refer to
AS3600
1 x 10mm GYPROCK
Plasterboard CD.
CSR 958
Refer to
AS3600
1 x 13mm GYPROCK
Plasterboard CD.
CSR 559
1 x 10mm GYPROCK
SUPACEIL
plasterboard.
Refer to
AS3600
CSR 560
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
Refer to
AS3600
CSR 561
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
Refer to
AS3600
CSR 562
Refer to
AS3600
E22
2 x 10mm GYPROCK
SUPERCHEK.
Rw / Rw+Ctr
Bare Floor
Ln,w+Ci
Carpet +
underlay
Ln,w+Ci
(a) Nil
61/53
60-65
40-45
66/58
55-60
40-45
67/59
55-60
40-45
66/58
55-60
40-45
(a) Nil
62/55
60-65
40-45
67/60
55-60
40-45
68/61
55-60
40-45
67/60
55-60
40-45
(a) Nil
61/53
60-65
40-45
66/58
55-60
40-45
67/59
55-60
40-45
66/58
55-60
40-45
(a) Nil
63/56
60-62
40-45
68/61
55-60
40-45
69/62
55-60
40-45
68/61
55-60
40-45
(a) Nil
64/57
60-62
40-45
69/62
55-60
40-45
70/63
55-60
40-45
69/62
55-60
40-45
(a) Nil
66/60
60-62
40-45
71/65
55-60
40-45
72/66
55-60
40-45
71/65
55-60
40-45
CAViTY inFiLL
(Refer to Section A)
Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
FRL
Report/Opinion
SYSTeM
n
CSR 563
30/30/30
EWFA 26162
CeiLinG LininGS
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
Furring channels at
450mm maximum
centres.
CSR 564
60/60/60
2 x 13mm GYPROCK
FYRCHEK
plasterboard.
+RISF 30
minutes
EWFA 26162
CSR 565
60/60/60
+RISF 60
minutes
EWFA 26162
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).
CSR 566
90/90/90
2 x 16mm GYPROCK
FYRCHEK
plasterboard.
+RISF 60
minutes
EWFA 26162
CSR 567
120/120/120
+RISF 60
minutes
EWFA 26162
3 x 16mm GYPROCK
FYRCHEK
plasterboard.
Rw / Rw+Ctr
Bare Floor
Ln,w+Ci
Carpet +
underlay
Ln,w+Ci
(a) Nil
63/56
60-62
40-45
68/61
55-60
40-45
69/62
55-60
40-45
68/61
55-60
40-45
(a) Nil
66/59
60-62
40-45
71/64
55-60
40-45
72/65
55-60
40-45
71/64
55-60
40-45
(a) Nil
68/62
60-62
40-45
73/67
55-60
40-45
74/68
55-60
40-45
73/67
55-60
40-45
(a) Nil
68/62
60-62
40-45
73/67
55-60
40-45
74/68
55-60
40-45
73/67
55-60
40-45
(a) Nil
70/64
55-60
40-45
75/69
50-55
40-45
76/70
50-55
40-45
75/69
50-55
40-45
CAViTY inFiLL
(Refer to Section A)
E23
Roof/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
FRL
Report/Opinion
SYSTeM
n
CeiLinG LininGS
CAViTY inFiLL
Steel Roofing
with Anticon
(Refer to Section A)
Tiled Roof
without Sarking
Tiled Roofing
with Sarking
Rw / Rw+Ctr
CSR 948
1 x 10mm GYPROCK
Plasterboard CD.
//
NOTE: Framing at
450mm max. centres.
42/32
40/35
42/36
43/34
41/36
43/38
42/32
40/35
42/36
43/33
41/36
43/37
44/35
42/37
44/39
43/33
41/36
43/37
42/32
40/35
42/36
43/34
41/36
43/38
42/32
40/35
42/36
44/35
45/39
46/40
46/37
46/40
48/41
44/35
45/39
46/40
47/38
46/41
48/42
49/40
47/43
49/44
47/38
46/41
48/42
49/40
50/44
51/45
51/42
51/45
53/46
49/40
50/44
51/45
CSR 952
1 x 13mm GYPROCK
Plasterboard CD.
//
CSR 949
1 x 10mm GYPROCK
SUPACEIL
plasterboard.
//
CSR 950
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
//
CSR 953
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
//
CSR 951
//
E24
2 x 10mm GYPROCK
SUPERCHEK.
Roof/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
FRL
Report/Opinion
SYSTeM
n
CeiLinG LininGS
CAViTY inFiLL
Steel Roofing
with Anticon
(Refer to Section A)
Tiled Roof
without Sarking
Tiled Roofing
with Sarking
Rw / Rw+Ctr
CSR 954
30/30/30
EWFA 26162
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
44/35
42/38
45/39
46/38
43/39
46/40
NOTE: Framing at
450mm max. centres.
44/35
42/38
45/39
49/40
47/43
50/44
51/42
48/44
51/45
49/40
47/43
50/44
49/40
47/43
50/44
51/42
48/44
51/45
49/40
47/43
50/44
51/42
50/45
52/46
52/44
51/45
53/47
51/42
50/45
52/46
54/45
53/48
55/49
55/47
54/49
56/50
54/45
53/48
55/49
CSR 956
60/60/60
2 x 13mm GYPROCK
FYRCHEK
plasterboard.
+RISF 30
minutes
EWFA 26162
CSR 870
60/60/60
+RISF 60
minutes
EWFA 26162
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).
CSR 871
90/90/90
2 x 16mm GYPROCK
FYRCHEK
plasterboard.
+RISF 60
minutes
EWFA 26162
CSR 955
120/120/120
+RISF 60
minutes
EWFA 26162
3 x 16mm GYPROCK
FYRCHEK
plasterboard.
E25
Roof/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
FRL
Report/Opinion
SYSTeM
n
CeiLinG LininGS
CAViTY inFiLL
Steel Roofing
with Anticon
(Refer to Section A)
Tiled Roof
without Sarking
Tiled Roofing
with Sarking
Rw / Rw+Ctr
CSR 862
1 x 10mm GYPROCK
Plasterboard CD.
//
44/34
42/37
44/38
45/36
43/38
45/40
44/34
42/37
44/38
45/35
43/38
45/39
46/37
44/39
46/41
45/35
43/38
45/39
45/35
43/38
45/39
46/37
44/39
46/41
45/35
43/38
45/39
46/37
47/41
48/42
48/39
48/42
50/43
46/37
47/41
48/42
49/40
48/43
50/44
51/42
49/45
51/46
49/40
48/43
50/44
47/37
45/40
47/41
48/39
46/41
48/43
47/37
45/40
47/41
CSR 842
1 x 13mm GYPROCK
Plasterboard CD.
//
CSR 868
1 x 6mm CeminSeal
Wallboard.
//
CSR 863
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
//
CSR 864
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
//
CSR 843
//
E26
2 x 10mm GYPROCK
Plasterboard CD.
Roof/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
FRL
Report/Opinion
SYSTeM
n
CSR 844
30/30/30
EWFA 26162
CeiLinG LininGS
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
Furring channels at
450mm maximum
centres.
CAViTY inFiLL
Steel Roofing
with Anticon
(Refer to Section A)
Tiled Roof
without Sarking
Tiled Roofing
with Sarking
Rw / Rw+Ctr
46/37
44/40
47/41
48/40
45/41
48/42
46/37
44/40
47/41
51/42
49/45
52/46
53/44
50/46
53/47
51/42
49/45
52/46
51/42
49/45
52/46
53/44
50/46
53/47
51/42
49/45
52/46
53/44
52/47
54/48
54/46
53/47
55/49
53/44
52/47
54/48
56/47
55/50
57/51
57/49
56/51
58/52
56/47
55/50
57/51
CSR 874
60/60/60
2 x 13mm GYPROCK
FYRCHEK
plasterboard.
+RISF 30
minutes
EWFA 26162
CSR 875
60/60/60
+RISF 60
minutes
EWFA 26162
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).
CSR 876
90/90/90
2 x 16mm GYPROCK
FYRCHEK
plasterboard.
+RISF 60
minutes
EWFA 26162
CSR 867
120/120/120
+RISF 60
minutes
EWFA 26162
3 x 16mm GYPROCK
FYRCHEK
plasterboard.
E27
Roof/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
FRL
Report/Opinion
SYSTeM
n
CeiLinG LininGS
CAViTY inFiLL
Steel Roofing
with Anticon
(Refer to Section A)
Tiled Roof
without Sarking
Tiled Roofing
with Sarking
Rw / Rw+Ctr
CSR 850
1 x 13mm GYPROCK
Plasterboard CD.
//
47/37
44/40
47/41
48/39
46/41
48/43
47/37
44/40
47/41
46/36
44/39
46/40
47/38
45/40
47/42
46/36
44/39
46/40
48/39
49/43
50/44
50/41
50/44
52/45
48/39
49/43
50/44
51/42
50/45
52/46
53/44
51/47
53/48
51/42
50/45
52/46
53/44
54/48
55/49
55/46
55/49
58/50
53/44
54/48
55/49
CSR 854
1 x 10mm GYPROCK
SUPACEIL
plasterboard.
//
CSR 851
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
//
CSR 853
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
//
CSR 852
//
E28
2 x 10mm GYPROCK
SUPERCHEK
plasterboard.
Roof/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
FRL
Report/Opinion
SYSTeM
n
CSR 855
30/30/30
EWFA 26162
CeiLinG LininGS
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
Furring channels at
450mm maximum
centres.
CAViTY inFiLL
Steel Roofing
with Anticon
(Refer to Section A)
Tiled Roof
without Sarking
Tiled Roofing
with Sarking
Rw / Rw+Ctr
48/39
46/42
49/43
50/42
47/43
50/44
48/39
46/42
49/43
53/44
51/47
54/48
55/46
52/48
55/49
53/44
51/47
54/48
53/44
51/47
54/48
55/46
53/48
55/49
53/44
51/47
54/48
55/46
54/49
56/50
56/48
55/49
57/51
55/46
54/49
56/50
58/49
57/52
59/53
59/51
58/53
60/54
58/49
57/52
59/53
CSR 856
60/60/60
2 x 13mm GYPROCK
FYRCHEK
plasterboard.
+RISF 30
minutes
EWFA 26162
CSR 857
60/60/60
+RISF 60
minutes
EWFA 26162
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).
CSR 858
90/90/90
2 x 16mm GYPROCK
FYRCHEK
plasterboard.
+RISF 60
minutes
EWFA 26162
CSR 859
120/120/120
+RISF 60
minutes
EWFA 26162
3 x 16mm GYPROCK
FYRCHEK
plasterboard.
E29
Roof/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
FRL
Report/Opinion
SYSTeM
n
CeiLinG LininGS
CAViTY inFiLL
(Refer to Section A)
Rw / Rw+Ctr
CSR 891
1 x 13mm GYPROCK
Plasterboard CD.
//
46/37
46/37
45/36
45/36
47/38
47/38
CSR 896
1 x 10mm GYPROCK
SUPACEIL
plasterboard.
//
CSR 898
30/30/30
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
Furring channels at
450mm maximum
centres.
EWFA 26162
CSR 892
60/60/60
+RISF 30
minutes
EWFA 26162
CSR 893
60/60/60
+RISF 60
minutes
EWFA 26162
2 x 13mm GYPROCK
FYRCHEK
plasterboard.
48/39
48/39
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
50/42
50/42
52/44
52/44
1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).
CSR 894
120/120/120
+RISF 60
minutes
EWFA 26162
E30
3 x 16mm GYPROCK
FYRCHEK
plasterboard.
Roof/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
FRL
Report/Opinion
SYSTeM
n
CeiLinG LininGS
CAViTY inFiLL
(Refer to Section A)
Rw / Rw+Ctr
CSR 065
1 x 10mm GYPROCK
Plasterboard CD.
//
45/36
45/36
46/36
46/36
45/36
45/36
47/38
47/38
48/39
48/39
49/40
49/40
CSR 860
1 x 13mm GYPROCK
Plasterboard CD.
//
CSR 066
1 x 10mm GYPROCK
SUPACEIL
plasterboard.
//
CSR 067
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
//
CSR 068
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
//
CSR 069
//
2 x 10mm GYPROCK
SUPERCHEK
plasterboard.
E31
Roof/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
FRL
Report/Opinion
SYSTeM
n
CSR 070
30/30/30
EWFA 26162
CeiLinG LininGS
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
Furring channels at
450mm maximum
centres.
CAViTY inFiLL
(Refer to Section A)
Rw / Rw+Ctr
47/38
47/38
CSR 071
60/60/60
+RISF 30
minutes
EWFA 26162
CSR 072
60/60/60
+RISF 60
minutes
EWFA 26162
2 x 13mm GYPROCK
FYRCHEK
plasterboard.
51/41
51/41
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
51/43
51/43
51/43
51/43
1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).
CSR 073
90/90/90
+RISF 60
minutes
EWFA 26162
E32
2 x 16mm GYPROCK
FYRCHEK
plasterboard.
Roof/Ceiling Systems
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA056
FRL
Report/Opinion
SYSTeM
n
CeiLinG LininGS
Rw / Rw+Ctr
CSR 873
1 x 13mm GYPROCK
Plasterboard CD.
//
46/37
46/37
47/38
47/38
45/36
45/36
CSR 877
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
//
CSR 872
30/30/30
EWFA 26162
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
Furring channels at
450mm maximum
centres.
CSR 878
60/60/60
+RISF 30
minutes
EWFA 26162
CSR 880
60/60/60
+RISF 60
minutes
EWFA 26162
2 x 13mm GYPROCK
FYRCHEK
plasterboard.
51/42
51/42
1 x 13mm GYPROCK
FYRCHEK
plasterboard.
52/43
52/43
50/42
50/42
52/44
52/44
1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).
CSR 865
90/90/90
2 x 16mm GYPROCK
FYRCHEK
plasterboard.
+RISF 60
minutes
EWFA 26162
CSR 866
120/120/120
+RISF 60
minutes
EWFA 26162
3 x 16mm GYPROCK
FYRCHEK
plasterboard.
E33
ACOuSTiC
OPiniOn
PKA052
FRL
Report/Opinion
60/60/60
from top
only
SYSTeM
n
Above
CSR 981
FAR 2358
60/60/60
from top
only
CeiLinG LininGS
CSR 982
FAR 2358
E34
38/31
42/33
45/36
(a) Nil
33/30
(a) Nil
44/37
50/41
(a) Nil
36/33
(a) Nil
36/33
CSR 986
Above
120/120/120
3 x 16mm GYPROCK FYRCHEK.
from top
CSR 985
below
only
FAR 2358
(a) Nil
Nil.
Above
120/120/120
2 x 16mm GYPROCK FYRCHEK.
from top
CSR 983
below
only
FAR 2358
Rw / Rw+Ctr
Above
FAR 2358
90/90/90
from top
only
Nil.
ACOuSTiC
OPiniOn
PKA052
FRL
Report/Opinion
60/60/60
FAR 2358
SYSTeM
n
CeiLinG LininGS
Above & below
90/90/90
Above & below
from below
120/120/120 CSR 992 2 x 16mm GYPROCK FYRCHEK
plasterboard.
from above
FAR 2358
Rw / Rw+Ctr
41/35
45/37
(a) Nil
47/41
51/43
(a) Nil
49/43
53/45
Above
SYSTeM SPeCiFiCATiOn
ACOuSTiC
OPiniOn
PKA052
FRL
Report/Opinion
60/60/60
from top
only
SYSTeM
n
CeiLinG LininGS
Above
CSR 987
FAR 2358
90/90/90
FAR 2358
CSR 995
Rw / Rw+Ctr
64
102
(a) Nil
38/31
42/35
43/34
47/38
(a) Nil
41/34
46/40
46/37
51/43
(a) Nil
44/37
48/42
49/40
53/45
E35
ACOUSTIC
OPINION
PKA-A071
=TL413
=TLi413
SYSTEM
N
CEILING LININGS
CAVITY INFILL
Rw / Rw+Ctr
Ln,w+CI
Hebel 1600
240/240/240
from above
FCO 1303
//
from below
240/240/240
from above
FCO 1303
120/120/120
from below
Nil
(a) Nil
33/30
45
3 x 16mm GYPROCK
FYRCHEK plasterboard
58/54
34
Hebel 1635
EWFA 26162
E36
ACOuSTiC
OPiniOn
OR
TeST
TYPiCAL LAYOuT
Refer to
CSR Fricker
OR
Fricker Easy Access System with appropriate acoustic
ceiling tiles
OR
Fricker Ceiling Tile
Material &
Thickness
Mineral Fibre
19mm
Mineral Fibre
15mm
Mineral Fibre
15mm
Mineral Fibre
15mm
Mineral Fibre
19mm
Mineral Fibre
15mm
Mineral Fibre
15mm
Mineral Fibre
15mm
Mineral Fibre
15mm
Mineral Fibre
15mm
Fricker 610-A
Fricker 611-A
Fricker 616-A
Ceiling System
Edge
Details
Colour
NRC
CAC
(db)
LR
SQ
SLT
FLB
SQ
SLT
SQ
SLT
SQ
SLT
White
White
White
White
White
White
White
White
White
.70-.80
.75-.85
.70-.80
.50-.60
.50-.60
.55
.55
.50
.50
35
35
35
33-35
33-35
33-35
33-35
30-35
30-35
89%
89%
89%
84%
84%
84%
84%
87%
87%
SQ
White
.70
35
87%
SQ
TB
AK
SQ
TB
AK
SQ
SBK
SQ
SBK
SQ
SBK
White
White
White
White
White
White
White
White
White
White
White
White
.55-.60
.55-.60
.55-.60
.55-.60
.55-.60
.55-.60
.70
.70
.55
.55
.70
.70
36-40
36-40
36-40
36-40
36-40
36-40
33-39
33-39
33-39
33-39
33-39
33-39
87%
87%
87%
87%
87%
87%
88%
88%
88%
88%
88%
88%
TWE
TWA
OWE
FC
WP
notes:
edge Details
Ceiling System
SQ = Square,
SLT = Shadowline Tapered
FLB = Fineline Bevel
TB = Tegular
SBK = Kerfed, Bevelled and Cut Back
AK = Shiplap
AK (F) = Tongue & Groove direct fix
Custom tile options, metal pan perforations and module sizes are available. Please contact your local CSR Fricker Comprador sales office on
1300 FRICKER (1300 374 253) for further information or detailed technical data sheets on individual products.
Shadowline
tapered
Tegular /
Fineline Bevel
Kerfed, Bevelled
and Cut Back
Shiplap
Shiplap (F)
E37
ACOuSTiC
OPiniOn
OR
TeST
TYPiCAL LAYOuT
Refer to
CSR Fricker
OR
Fricker Easy Access System with appropriate acoustic
ceiling tiles
OR
Fricker Ceiling Tile
Ceiling System
Edge
Details
Colour
NRC
CAC
(db)
LR
SQ
AK
TB
AK (F)
SQ
AK (F)
White Frost
White Frost
White Frost
White Frost
White Frost
White Frost
.85
.80
.80
.75
.95
.95
21
25
23
n/a
30
n/a
85%
85%
85%
85%
85%
85%
Ecophon Solo S
Glasswool
40mm
SQ
White Frost
n/a
n/a
85%
Glasswool
20mm
SQ
White Frost
.80
n/a
84%
SQ
White Frost
.85-.95
n/a
84%
SQ
Turquoise
.95-1.0
n/a
49%
Glasswool
40mm
SQ
SQ
SQ
Brown 610
Cerise 810
Med Grey 920
.95-1.0
.95-1.0
.95-1.0
n/a
n/a
n/a
14%
16%
34%
Plasterboard
13mm
SQ
.49
n/a
n/a
SQ
TB
SQ
TB
.70
.70
.85
.85
13
13
30
30
68%
68%
68%
68%
Ecophon Focus A
Ecophon Focus Ds
Ecophon Focus E
Ecophon Focus F
Ecophon Master A
Ecophon Master F
Material &
Thickness
Glasswool
20mm
Glasswool
40mm
Glasswool
20mm
Glasswool
40mm
Steel 0.7mm
Steel 0.7mm
TWE
TWA
OWE
FC
WP
notes:
edge Details
Ceiling System
SQ = Square,
SLT = Shadowline Tapered
FLB = Fineline Bevel
TB = Tegular
SBK = Kerfed, Bevelled and Cut Back
AK = Shiplap
AK (F) = Tongue & Groove direct fix
Custom tile options, metal pan perforations and module sizes are available. Please contact your local CSR Fricker Comprador sales office on
1300 FRICKER (1300 374 253) for further information or detailed technical data sheets on individual products.
E38
Shadowline
tapered
Tegular /
Fineline Bevel
Kerfed, Bevelled
and Cut Back
Shiplap
Shiplap (F)
FiG e3: inSTALLATiOn DeTAiL SinGLe LAYeR ADHeSiVe & nAiL/SCReW FiXinG
For additional information, refer to GYP570, Gyprock Ceiling Systems Installation Guide.
For 1350mm width sheets, hold
sheet with temporary fastener
through block at every second joist
until adhesive sets
Timber or steel
framing
Adhesive Daubs
nOn-FiRe RATeD
Fixing Specifications
230mm
max.
centres
2 Nails 50 to
75mm apart
or 1 screw
200mm
min. cts
200mm
min. cts
300mm max.
for cornice finish
150mm max.
for set finish
Fasteners
Adhesive
Refer to Section A
Gyprock Stud Adhesive
Location
Field
Sheet
Width
900mm
1200mm
1350mm
Adhesive Daubs at
230mm max. centres
and 200mm min. from
fastener points
2 daubs
4 daubs
4 daubs
Recessed
Joints
Centreline
of
Sheet
2 nails at 50 to 75mm
apart or 1 screw at each
frame member
Butt
Joints
between
framing
Butt
Joints on
framing
Openings
Sheet
Ends
FiG e4: inSTALLATiOn DeTAiL TWO LAYeR ADHeSiVe & SCReW FiXinG
For additional information, refer to GYP570, Gyprock Ceiling Systems Installation Guide.
2nd Layer
Fasteners
Adhesive
1st Layer
Body
Sheet
Width
900mm
1200mm
1350mm
Butt Joints
on framing
Sheet
Ends &
Openings
2nd Layer
Body
200mm max.
230mm
max.
300mm
max.
300mm max.
for cornice finish
150mm max.
for set finish
200mm min.
Adhesive
Daubs
nOn-FiRe RATeD
Fixing Specifications
1st Layer Refer to Section A
Gyprock Stud Adhesive
Screws
230mm max.
200mm min.
Temporary block
Refer to Section A
Gyprock Stud Adhesive
Fixing & Spacing
Screw fix to each
framing member at
300mm max. centres
4 screws equally spaced
5 screws equally spaced
6 screws equally spaced
Screw fix at 200mm
max. centres
Screw fix at 300mm
max. centres
E39
For additional information, refer to GYP570, Gyprock Ceiling Systems Installation Guide.
nOn-FiRe RATeD
Practical
minimum 150mm
Structural support
of timber, steel or
concrete
Fixing Specifications
Screws
Suspended Grid at
600mm maximum
centres
Recessed
Joints
& Body
Sheet
Width
900mm
1200mm
1350mm
300mm
max.
Refer to Section A
Location
Openings
Sheet
Ends
For additional information, refer to GYP570, Gyprock Ceiling Systems Installation Guide.
Framing at 600mm centres
nOn-FiRe RATeD
Fixing Specifications
Screws
Refer to Section A
Location
Recessed
Joints &
Body
Openings
E40
For additional information, refer to GYP570, Gyprock Ceiling Systems Installation Guide.
FiRe RATeD
Refer to system
specifications
Fixing Specifications
Fasteners
Body of
Sheet
Butt
Joints
Openings
Fasten at
150mm max. centres
Sheet
Ends
15mm
40mm
25mm
150mm
max.
40mm
15mm
min.
Refer to Section A
Location
200mm max.
150mm max.
Perimeter track/angle
required in fire rated
ceiling systems (refer
to Perimeter Details)
FiG e8: inSTALLATiOn DeTAiL One OR TWO LAYeR nAiL OR SCReW FiXinG
FOR SYSTeMS WiTH LininG ABOVe OR BeLOW FRAMinG
For additional information, refer to GYP570, Gyprock Ceiling Systems Installation Guide.
FiRe RATeD
Refer to system
specifications
Fixing Specifications
Fasteners
40mm
25mm
40mm
40mm 40mm
200mm
max.
150mm
max.
15mm
15mm
min.
25mm
Body of
Sheet
1st & 2nd
Layer
Butt
Joints
1st Layer
Butt
Joints
2rd layer
Sheet
Ends
Openings
200mm max.
Refer to Section A
Location
Begin 1st
layer with half
width sheet
E41
FiG e9: inSTALLATiOn DeTAiL THRee LAYeR FiXinG TO STeeL OR TiMBeR FRAMinG nAiL OR SCReW FiXinG
For additional information, refer to GYP570, Gyprock Ceiling Systems Installation Guide.
FiRe RATeD
Fixing Specifications
Fasteners
25mm
40mm
25mm
40mm
40mm
150mm
max.
150mm
40mm
40mm
15mm
15mm
min.
Body of
Sheet
1st & 2nd
Layers
Butt
Joints
1st & 2nd
Layers
Butt
Joints
3rd layer
Sheet
Ends all
Layers
Body of
Sheet 3rd
Layer
Laminating screws at
400mm max. in each
direction
Openings
200mm max.
150mm
max.
15mm
40mm
400mm
max.
Perimeter track/angle
required in fire rated
ceiling systems (refer
to Perimeter Framing
& Caulking)
200mm
max.
400mm
max.
Refer to Section A
Location
For additional information, refer to GYP570, Gyprock Ceiling Systems Installation Guide.
FiRe RATeD
Top Layers Fixing Specifications
Fasteners
300mm
max.
150mm
max.
Refer to Section A
Location
Body of
Sheet
All Layers
Butt
Joints
Sheet
Ends
200mm
max.
150mm
max.
FiRe RATeD
150mm
max.
200mm
max.
150mm
max.
Bottom Layers
Fixing Specifications
Fasteners
Refer to Section A
Sheet
fixing
E42
FiG e11: TYPiCAL inSTALLATiOn DeTAiL ROnDO DuO eXPOSeD GRiD SuSPenDeD CeiLinG SYSTeM
Practical minimum
150mm
Wall Angle
Trim
1200mm max.
between suspension
points
Main
Tee
300mm
Tile Hold Down Clip
N703 (optional)
Cross Tee
600mm
300mm
GYPROCK plasterboard
or accoustic tile
1200mm
600mm
Cross Tee
Duo 4
Main Tee
Duo 1/Duo 3
FiG e12: TYPiCAL inSTALLATiOn DeTAiL FRiCKeR eASY ACCeSS SYSTeM WiTH ACOuSTiC CeiLinG TiLeS
Fricker Suspension Clip
and 5mm hanging rod
staggered at 1200mm
centres
Fricker Top Hat Cross
Runner every third tile
Modules of
1000 x 1000mm to
1500 x 1500mm
Tiles can be
rotated 90 in
modules
E43
notes
E44
Section F
Services Systems
Contents
Introduction
F2
Fire Resistance
F2
Acoustic Performance
F2
F3
Components
F3
System Specifications
F4
F5
F6
F7
F9
F1
Introduction
Gyprock Services Systems are ducts, risers, bulkheads
and ceilings that provide protection from noise generated by
building services. These services include water supply pipes,
waste and storm water pipes, and air conditioning ducts.
The BCA has deemed to satisfy performance requirements
that vary depending on the room use adjacent to the service,
and there are some State variations. The requirements are
R w + Ctr = 25 to a kitchen or non-habitable room, and
Rw + Ctr = 40 for habitable rooms other than kitchens. The
State variations are for Rw = 30 and Rw = 45 for the same
respective room types.
For services located within separating walls, refer to
Section Z for details and performance information.
Fire Resistance
The services systems in this section have no Fire Resistance
Level. They may be used in conjunction with fire rated
wall and ceiling systems selected from elsewhere in this
manual.
Acoustic
Performance
The acoustic transmission performance of the services
systems is dependent on the type of support framing. In
some systems, higher ratings can be achieved with timber
framing compared to light steel framing. In cavity systems,
this does not apply.
Services systems used as bulkheads or ceilings may
incorporate downlights. The distribution of downlights in
a services system is specified as the maximum number
permitted in a 5m 2 area. The lights shall be evenly
distributed and no closer than 900mm apart. Where higher
concentrations of lights are required, an acoustic engineer
should be consulted.
Penetrations for downlights must be neat and tight to the
fitting. No additional sealing is required. Ensure insulation
material is kept clear of fittings and that transformers are
supported separately from the plasterboard lining.
The installation of exhaust grilles and ducting may reduce the
performance of the systems. The building designer should
contact the exhaust system manufacturer for performance
details.
Similarly, access panels might be required. Contact the panel
manufacturer for suitable products.
Lagging of pipes or ducts is specified in some services
systems. Lagging must provide complete coverage for the
full extent of the pipe or duct.
Maximum
number of
downlights as
per system
specification
F2
Locally remove
insulation
Framing &
Lining
Framing shown in the system layout is indicative only. The
designer should ensure that framing elements are suitable for
the application. For systems specified with timber framing,
linings must be fixed directly to solid timber joists or studs of
minimum dimension 70 x 35mm that are spaced at 600mm
maximum centres. For all other framing construction, select
services systems that are specified for steel framing.
Except for fire grade plasterboard, fixing to framing may be
fastener only or combination fastener/adhesive. Refer to the
Gyprock Residential Installation Guide, NGYP547 and
Cemintel Wet Area Lining Systems, NFC101 for detailed
fixing, jointing and finishing information.
It should be noted that for all systems, setting joints is only
required for the outer layer.
For walls and ceilings, insulation must not be compressed
between the lining and any lagging or the service being
protected.
FIG F2: InsulaTIon CompRessIon
Components
Refer to Section A of this manual for detailed information on
CSR Gyprock plasterboard and Cemintel lining products,
jointing compounds, and fastener specifications.
CSR recommends steel components manufactured by
Rondo Building Services Pty Ltd. Additional information
on the steel components can be obtained from the Rondo
Building Services Pty Ltd, telephone 1300 367 663.
Downlights may be of any non-gimbal type with glass cover,
suitable for a circular cut-out of up to 80mm diameter. Lights
weighing more than 250g must be supported separately
from the plasterboard lining.
Acoustilag 45 consists of 25mm Bradford glasswool
bonded to 4.5kg/m2 loaded vinyl. The glasswool side is to
be installed facing the service pipe or duct.
Lagging is to completely cover the service duct or pipe. Remove
a 50mm wide strip of glasswool and overlap at joints. Tape with
a quality aluminium tape.
75mm 25mm
Insulation
Service
lagging
F3
aCousTIC
opInIon
pKa058
system n
linings
CsR ss44
Insulation
(Refer to System Specification)
pipe lagging
maximum n
downlights
per 5m2
Rw + Ctr
Nil
26
Acoustilag 45
40
Nil
30
Acoustilag 45
42
(a) Nil
Nil
25
Nil
28
Nil
28
Acoustilag 45
42
(a) Nil
Nil
26
Acoustilag 45
43
(a) Nil
Nil
31
(b) Nil
Acoustilag 45
45
1 x 10mm GYPROCK
AQUACHEK plasterboard.
CsR ss45
1 x 6mm CeminSeal
Wallboard.
CsR ss01
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
CsR ss02
1 x 13mm GYPROCK
plasterboard CD.
CsR ss04
2 x 10mm GYPROCK
plasterboard CD.
CsR ss46
2 x 16mm GYPROCK
FYRCHEK plasterboard.
F4
aCousTIC
opInIon
pKa058
system n
linings
Insulation
(Refer to System Specification)
pipe lagging
maximum n
downlights Rw + Ctr
per 5m2
CsR ss08
(a) 75 GW Partition 11kg
Nil
25
Acoustilag 45
38
Nil
27
Acoustilag 45
41
Nil
26
(b) Nil
Acoustilag 45
36
Acoustilag 45
40
(a) Nil
Nil
27
(b) Nil
Acoustilag 45
41
Acoustilag 45
43
Nil
Nil
25
Acoustilag 45
42
Nil
Nil
31
Acoustilag 45
44
1 x 10mm GYPROCK
AQUACHEK plasterboard.
CsR ss10
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
CsR ss11
1 x 13mm GYPROCK
plasterboard CD.
CsR ss12
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
CsR ss13
2 x 10mm GYPROCK
plasterboard CD.
CsR ss17
2 x 16mm GYPROCK
FYRCHEK plasterboard.
F5
aCousTIC
opInIon
pKa058
system n
linings
CsR ss20
Insulation
(Refer to System Specification)
pipe lagging
maximum n
downlights
per 5m2
Rw
Nil
30
Acoustilag 45
50
Nil
31
Acoustilag 45
52
Nil
31
Acoustilag 45
52
Nil
31
Acoustilag 45
52
(a) Nil
Nil
31
Acoustilag 45
54
(a) Nil
Nil
34
Nil
40
1 x 10mm GYPROCK
AQUACHEK plasterboard.
CsR ss18
1 x 6mm CeminSeal
Wallboard.
CsR ss21
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
CsR ss22
1 x 13mm GYPROCK
plasterboard CD.
CsR ss23
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.
CsR ss19
2 x 16mm GYPROCK
FYRCHEK plasterboard.
F6
aCousTIC
opInIon
pKa058
system n
linings
CsR ss30
Insulation
(Refer to System Specification)
pipe lagging
maximum n
downlights
per 5m2
Rw
(a) Nil
Nil
22
Acoustilag 45
48
Nil
30
Acoustilag 45
51
Nil
30
Acoustilag 45
51
Nil
30
Acoustilag 45
50
Nil
31
Acoustilag 45
52
(a) Nil
Nil
34
(b) Nil
Acoustilag 45
55
1 x 10mm GYPROCK
AQUACHEK plasterboard.
CsR ss38
1 x 6mm CeminSeal
Wallboard.
CsR ss31
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.
CsR ss32
1 x 13mm GYPROCK
plasterboard CD.
CsR ss34
2 x 10mm GYPROCK
plasterboard CD.
CsR ss39
2 x 16mm GYPROCK
FYRCHEK plasterboard.
F7
aCousTIC
opInIon
pKa052
system n
linings
CsR ss40
Insulation
(Refer to System Specification)
maximum n
downlights Rw/Rw+Ctr
per 5m2
Nil
46/37
Nil
46/39
Inner Layer
Nil
49/40
Nil
49/42
Inner Layer
Nil
53/44
Nil
53/46
Inner Layer
1 x 13mm GYPROCK SOUNDCHEK plasterboard.
Outer Layer/CeILIng
CsR ss41
2 x 13mm GYPROCK FYRCHEK.
Outer Layer/CeILIng
CsR ss42
2 x 13mm GYPROCK FYRCHEK.
Outer Layer/CeILIng
2 x 13mm GYPROCK Plasterboard CD.
F8
1 x 13mm
GYPROCK
Plasterboard CD
Waste Pipe
75mm Bradford
Glasswool
Partition Batts 11kg/m3
75mm min.
clearance
75 Partition Batts - 11kg/m3
1 x 10mm
GYPROCK
Plasterboard CD
each side of steel
studs
Habitable room
1 x 13mm GYPROCK
Plasterboard CD
Non-habitable room
Waste
Pipe
75mm Bradford
Glasswool
Partition Batts 11kg/m3
Acoustilag 45
Timber or
steel framing
1 x 13mm
GYPROCK
Plasterboard CD
each side of steel
studs
Habitable room
1 x 13mm GYPROCK
Plasterboard CD
600mm min.
Non-habitable room
F9
notes
F10
Section G
Contents
Introduction
G2
G3 G12
G13 G15
G16 G18
G1
Introduction
Acoustic Performance
Flanking sounds reach adjoining areas by indirect paths,
rather than through the dividing element. The components
and cavities of the walls, floors and ceilings that surround the
dividing element are the main paths for flanking transmission.
When designing for room-to-room performance, all flanking
paths should be considered, as well as the dividing element
itself.
The flanking path values in this section are a guide to the
maximum sound transmission values that would be achieved
in a laboratory test. The rating assumes that the dividing
wall that is being flanked has an equivalent or higher sound
transmission performance (Rw or Rw + Ctr) than the flanking
value. Where a flanking system has a rating higher than that
of the dividing wall, the room-to-room transmission should
be taken as the wall value.
Each flanking path system is represented by a typical layout,
and is associated with one or more details. The details
show an example of the construction required, but must be
amended to suit the system specification and lining. Dividing
walls shown as single studs may be substituted with other
construction such as staggered studs, double studs and
masonry walls to achieve the same results.
Panel ceiling systems must have no lights or penetrations
within 600mm of dividing wall and plasterboard ceilings
must have no acoustically untreated penetrations in rooms
adjacent to dividing wall.
Building systems and construction methods can vary greatly
from site to site. CSR recommends that where acoustic
performance is important, an acoustic engineer be consulted
to assess the suitability of the flanking system values detailed
in this section.
G2
ACOUSTIC
OPINION
TYPICAL LAYOUT
PKAA031
Steel angle to
support ceiling grid
100mm
min
System insulation
GYPROCK
Panel
Ceiling
System
EXTENT OF INSULATION
SYSTEM N
CEILING LININGS
Nil
Entire Ceiling
Rw
CSR FP01
38
44
45
21
24
25
42
48
49
30
31
31
30-35
30-36
30-36
35
35-36
35-36
SYSTEM SPECIFICATION
ACOUSTIC
OPINION
TYPICAL LAYOUT
PKAA031
System insulation
100mm
min
System insulation
Ceiling Framing
GYPROCK
plasterboard
ceiling
CEILING LININGS
Nil
Entire Ceiling
Rw / Rw+Ctr
CSR FP02
41/32
47/38
48/39
43/34
49/40
50/41
46/38
52/44
53/45
55/47
59/51
60/52
54/46
58/50
59/51
55/47
59/51
60/52
G3
ACOUSTIC
OPINION
TYPICAL LAYOUT
Fix wall track to ceiling
frame with Rondo 704
Partition Clip
System
insulation
PKAA031
Finish Bead as
required
GYPROCK Panel
Ceiling System
continuous over
wall in Rondo
DUO Two-way
Steel Grid
Continuous bead of
CSR Gyprock
Sealant or a closed
cell foam tape
above wall track
CEILING LININGS
Nil
Entire Ceiling
Rw
(a) 1 x 10mm GYPROCK Plasterboard panel.
CSR FP03
35
40
42
18-21
18-24
18-25
25-30
25-31
25-31
30-35
30-36
30-36
30-35
30-36
30-36
SYSTEM SPECIFICATION
ACOUSTIC
OPINION
TYPICAL LAYOUT
System insulation
Ceiling framing
PKAA031
Tape and
set or
cornice
finish
GYPROCK
plasterboard
ceiling system
continuous
over wall
CEILING LININGS
Nil
Entire Ceiling
Rw
CSR FP04
G4
37
42
42
39
45
45
43
48
50
47
48
50
47
48
50
48
48
50
ACOUSTIC
OPINION
TYPICAL LAYOUT
PKAA031
600mm
Finish Bead as
required
GYPROCK Panel
Ceiling System
continuous over
wall in Rondo
DUO Two-way
Steel Grid
Continuous bead of
CSR Gyprock
Sealant or a closed
cell foam tape
above wall track
Bradford
Glasswood 11kg/m3
compressed 30%
SYSTEM N
CSR FP10
CEILING LININGS
Rw
45
42
42
SYSTEM SPECIFICATION
ACOUSTIC
OPINION
TYPICAL LAYOUT
PKAA031
Ceiling
framing
600mm
GYPROCK
plasterboard
ceiling system
continuous
over wall
Tape and
set or
cornice
finish
Bradford
Glasswood 11kg/m3
compressed 30%
SYSTEM N
CSR FP11
CEILING LININGS
Rw
50
50
50
50
50
50
G5
ACOUSTIC
OPINION
TYPICAL LAYOUT
PKAA031
50mm Glasswool
seal continuous over
wall, held in place
with track or angle
10mm GYPROCK
plasterboard min.
continuous over wall
and fixed to soffit
GYPROCK Panel
Ceiling System in
Rondo DUO
Two-way Steel Grid
Finish Bead as
required
Fix track to ceiling
frame with Rondo
N704
SYSTEM N
Continuous bead of
CSR Gyprock
Sealant above wall
track
CEILING LININGS
Rw
48
35-40
40-45
40-45
CSR FP16
SYSTEM SPECIFICATION
ACOUSTIC
OPINION
TYPICAL LAYOUT
PKAA031
50mm Glasswool
seal continuous over
wall, held in place
with track or angle
10mm GYPROCK
plasterboard min.
continuous over wall
and fixed to soffit
Ceiling frame
GYPROCK
plasterboard
ceiling system
continuous
over wall
Wall with required
sound rating
SYSTEM N
CSR FP17
G6
CEILING LININGS
Rw
50
50
50
50
50
50
ACOUSTIC
OPINION
TYPICAL LAYOUT
PKAA031
Bradford Wavebar Quadzero
(4.0kg/m2) continuous over
wall and fixed to soffit
300mm min.
600mm min.
GYPROCK Panel
Ceiling System in
Rondo DUO
Two-way Steel Grid
Finish Bead as
required
Continuous bead of
CSR Gyprock Sealant
or closed cell foam
tape above wall track
SYSTEM N
50mm Glasswool
Blanket continuous
over wall
CEILING LININGS
Rw
48
35-40
40-45
40-45
CSR FP20
SYSTEM SPECIFICATION
ACOUSTIC
OPINION
TYPICAL LAYOUT
PKAA031
Bradford Wavebar Quadzero
(4.0kg/m2) continuous over
wall and fixed to soffit
300mm min.
50mm Glasswool
Blanket continuous
over wall
600mm min.
GYPROCK
plasterboard
ceiling system
continuous
over wall
Wall with required
sound rating
SYSTEM N
CSR FP21
CEILING LININGS
Rw / Rw+Ctr
50/40
50/40
50/41
50/42
50/42
50/42
G7
ACOUSTIC
OPINION
TYPICAL LAYOUT
Floor or roof structure
PKAA031
GYPROCK panel
ceiling system
50mm Bradford
Partition batts
11kg/m3 1200mm
each side of wall
Wall system with
required rating
SYSTEM N
CEILING LININGS
Rw
48
40
45
45
CSR FP025
SYSTEM SPECIFICATION
ACOUSTIC
OPINION
TYPICAL LAYOUT
Floor or roof structure
PKAA031
50mm Bradford
Partition batts
11kg/m3 1200mm
each side of wall
SYSTEM N
CEILING LININGS
Rw
50
52
54
55
CSR FP26
G8
ACOUSTIC
OPINION
TYPICAL LAYOUT
PKAA031
Roof structure.
500mm minimum average cavity height.
Roof framing
with 500mm
min. average
cavity
R2.5 Glasswool
Gold Batts
13mm + 16mm
GYPROCK FYRCHEK
Plasterboard
50mm Bradford
partition batts 11kg/m3
Lower ceiling
SYSTEM N
Rw / Rw+Ctr
65/53
66/54
66/54
67/55
CSR FP31
SYSTEM SPECIFICATION
ACOUSTIC
OPINION
TYPICAL LAYOUT
PKAA031
Sheet metal or
tiled roof
Roof framing with 500mm
min. average cavity
Roof structure.
Bradford Gold
batts R2.5
GYPROCK
plasterboard ceiling
SYSTEM N
CSR FP35
CEILING LININGS
Furring channel
and min. 40mm
cavity
Tape and set or
cornice finish
Rw / Rw+Ctr
47/39
51/43
52/44
53/45
59/51
G9
ACOUSTIC
OPINION
TYPICAL LAYOUT
Sheet metal or tiled roof
PKAA031
Roof structure.
Bradford Rockwool insulation between
battens.
Bradford Gold
batts R2.5
GYPROCK
plasterboard ceiling
(no acoustically
untreated lights,vents
or similar penetrations)
SYSTEM N
CSR FP40
CEILING LININGS
Rw / Rw+Ctr
65/55
65/55
SYSTEM SPECIFICATION
ACOUSTIC
OPINION
TYPICAL LAYOUT
PKAA031
20mm
0mm clearance
to stud and
GYPROCK
plasterboard
100mm max.
to first fastener
(Do not fix through
track)
SYSTEM N
CSR FP45
G10
Rw / Rw+Ctr
(a) 100mm
55/50
(b) 125mm
55/52
(c) 150mm
56/53
(d) 175mm
57/54
(e) 200mm
58/55
(f) 225mm.
58/56
(g) 250mm.
58/56
ACOUSTIC
OPINION
PKAA031
Roof structure.
500mm minimum average cavity height.
Bradford Gold Batts R1.5.
Ceiling lining as per system table fixed to framing.
CSR Party Wall system with required sound rating.
Central barrier extending to underside of roof battens.
SYSTEM N
CEILING LININGS
CSR FP50
Rw / Rw+Ctr
66/54
66/54
Non-combustible roofing
Roof battens
Roof framing
Wall Clips at
each H-Stud
both sides of wall
Roof sarking.
For roofs without sarking,
protect Rockwool with
damp course under tiles
600mm max.
Blocking to support
ceiling lining
No acoustically
untreated lights,
vents or similar
penetrations
200mm min.
Wall Clips at
each H-Stud
both sides of wall
No acoustically
untreated lights,
vents or similar
penetrations
GYPROCK SHAFT
LINER PANEL
20-40mm gap
each side of wall
G11
ACOUSTIC
OPINION
TYPICAL LAYOUT
Continuously
fill gap with
Gyprock
sealant
PKAA031
System insulation
Continuously
fill gap with
Gyprock
sealant
GYPROCK
plasterboard ceiling
system direct fixed to
joists or to furring/batten
CEILING LININGS
FIXED TO FURRING OR
BATTEN
Rw / Rw+Ctr
CSR FP55
G12
53/47
53/47
55/49
55/49
58/52
58/52
57/51
57/51
58/52
58/52
ACOUSTIC
OPINION
TYPICAL LAYOUT
Wall with required
sound rating
Discontinuous
flooring
PKAA031
Continuously
fill gap with
Gyprock
sealant
SYSTEM N
Rw / Rw+Ctr
CSR FP60
60/55
SYSTEM SPECIFICATION
ACOUSTIC
OPINION
TYPICAL LAYOUT
PKAA031
Continuously
fill gap with
Gyprock
sealant
SYSTEM N
Rw / Rw+Ctr
CSR FP61
48/42
G13
ACOUSTIC
OPINION
TYPICAL LAYOUT
PKAA031
Continuously
fill gap with
Gyprock
sealant
SYSTEM N
Rw / Rw+Ctr
CSR FP62
45/39
SYSTEM SPECIFICATION
TYPICAL LAYOUT
ACOUSTIC
OPINION
PKAA031
Continuously
fill gap with
Gyprock
sealant
G14
SYSTEM N
Rw / Rw+Ctr
CSR FP63
45/39
ACOUSTIC
OPINION
TYPICAL LAYOUT
PKAA031
Stud
GYPROCK
plasterboard
Fill gap with CSR Gyprock
Sealant for acoustic
integrity
Studs bottomed
in track
10mm max. gap
at bottom of sheet
SYSTEM N
CSR FP75
Rw / Rw+Ctr
(a) 100mm
55/50
(b) 125mm
55/52
(c) 150mm
56/53
(d) 175mm
57/54
(e) 200mm
58/55
(f) 225mm.
58/56
(g) 250mm.
58/56
G15
ACOUSTIC
OPINION
TYPICAL LAYOUT
PKAA031
GYPROCK
plasterboard as
per system table
Tape and
set corners
SYSTEM N
CSR FP80
WALL LININGS
Rw / Rw+Ctr
45/40
48/43
50/45
50/45
50/45
SYSTEM SPECIFICATION
ACOUSTIC
OPINION
TYPICAL LAYOUT
Stud frame wall system with min.
75mm Bradford Gold batts
PKAA031
GYPROCK
plasterboard as
Steel Angle (75 x 75 x
per system table
0.7mm BMT) fixed to
stud with panhead screw
at 600mm max. cts
Tape and
set corners
CSR Gyprock
Staggered Studs
and Clips
SYSTEM N
CSR FP82
G16
WALL LININGS
Rw / Rw+Ctr
51/43
53/45
54/46
53/45
54/46
ACOUSTIC
OPINION
PKAA031
10mm
nom. gap
from
masonry
to lining
SYSTEM N
CSR FP84
WALL LININGS
Rw / Rw+Ctr
51/43
52/44
54/46
53/45
54/46
SYSTEM SPECIFICATION
ACOUSTIC
OPINION
TYPICAL LAYOUT
Stud frame wall system with min.
75mm Bradford Gold batts
PKAA031
Sealant
GYPROCK
plasterboard as
per system table
Tape and
set corners
Sealant
SYSTEM N
CSR FP86
WALL LININGS
Rw / Rw+Ctr
58/50
58/50
G17
ACOUSTIC
OPINION
TYPICAL LAYOUT
PKAA031
Finish corners
as required
SYSTEM N
CSR FP88
Rw / Rw+Ctr
(a) 90kg/m2
53/48
(b) 150kg/m2
55/50
(c) 200kg/m2
56/51
SYSTEM SPECIFICATION
ACOUSTIC
OPINION
TYPICAL LAYOUT
PKAA031
GYPROCK
plasterboard as
per system table
Tape and
set corners
BARRIER
SYSTEM N
WALL LININGS
Nil
CSR FP90
G18
39/30
59/50
41/32
60/51
45/37
60/52
43/35
60/52
45/37
60/52
Section Z
Contents
Junctions
Z2 Z6
Z7 Z8
Z9
Z10 Z11
Z12 Z16
Penetrations
Service Penetrations
Acoustic & Fire Performance
Z17 Z18
Penetration Details
Z19 Z24
Z1
6 10mm
clearance to
GYPROCK
plasterboard
100mm max.
to first fastener
(Do not fix
through track)
Stud
6mm
clear
of
soffit
Stud
Suspended Ceiling
Top Cross Rail
20mm gap
100mm max.
(do not fix
through track)
NOTE: Stopping bead
or cornice finish as
required. Do not rigidly
fix cornice to walls
where friction joints are
used
Fix cornice to
ceiling only with
Gyprock Cornice
Cement
Stud
GYPROCK plasterboard
ceiling fixed to furring
channel at appropriate
centres
Proprietary extruded
aluminium track
Stud
Z2
Finish as required
Flexible Mastic
Furring Channel in
normal setout position
Stud
GYPROCK
plasterboard
Studs bottomed
in track
10mm max. gap
at bottom of sheet
System
insulation
Ceiling framing
Tape and
set or
cornice
finish
GYPROCK
plasterboard
ceiling system
continuous
over wall
100mm
min
System insulation
System insulation
Ceiling Framing
Finish Bead as
required
GYPROCK Panel
Ceiling System
continuous over
wall in Rondo
DUO Two-way
Steel Grid
Continuous bead of
CSR Gyprock
Sealant or a closed
cell foam tape
above wall track
Steel angle to
support ceiling grid
System insulation
GYPROCK
plasterboard
ceiling
100mm
min
GYPROCK Panel
Ceiling System
50mm Bradford
Partition batts
11kg/m3 1200mm
each side of wall
GYPROCK
plasterboard ceiling
system
GYPROCK panel
ceiling system
50mm Bradford
Partition batts
1200mm each
side of wall
Wall system with
required rating
Z3
CSR Gyprock
Staggered Stud Clip
10mm GYPROCK
AQUACHEK or
FYRCHEK MR
1 or 2 layers of GYPROCK
FYRCHEK MR
Single
or
double
stud
wall
system
Waterproofing sealer
applied to face of
plasterboard behind
tiled area
Vertical Corner
Angle Flashing
Ceramic Tiles
Nogging for
plasterboard fixing
Flashing Tape
(25mm min.)
Flexible Sealant
Screw fix
J-track to
stud
6mm
Preformed
Shower Base
Mortar Bed
Single
or
double
stud
wall
system
10mm GYPROCK
AQUACHEK
1 or 2 layers of
GYPROCK
FYRCHEK MR
Ceramic Tiles
Flashing Tape
(25mm min.)
Vertical Corner
Angle Flashing
Ceramic Tiles
Timber Stud
Insitu Internal Membrane
applied to face of
wall lining and floor
Approved Flashing
when required by
building regulations
Masking Tape
Foam plastic rod
used as essential
bond breaker
Mortar Bed
Flexible Sealant
Single
or
double
stud
wall
system
Continuously
fill 6mm gap
with CSR
Gyprock Fire
Mastic to
13mm
minimum
depth
6mm
Bath
Support Batten
fixed to framing
Mortar Bed
Z4
6 10mm
clearance to
plasterboard
100mm max. to
first fastener. Do
not fix through
head track
Stud
15mm
clear
of
soffit
100mm
max. to
Nogging
track
60mm
max.
Stud 15mm
clear of soffit
N8 Tek
screw one
side only
GYPROCK
FYRCHEK
plasterboard
1, 2 or 3 layers
N8 Tek
screw both
sides
100mm max. to
first fastener. Do
not fix through
head track
Suspended Ceiling
Top Cross Rail
Stud
10mm Gap
6mm Gap
Gyprock Fire
Mastic
Rondo P50
2 or 3 layers
GYPROCK
FYRCHEK
plasterboard
Stud
1, 2 or 3 layers
GYPROCK
FYRCHEK
plasterboard
Stud
GYPROCK
FYRCHEK
plasterboard
1, 2 or 3 layers
Studs bottomed
in track
10mm Gap
10mm Gap
Continuously fill gap
with CSR Gyprock
Fire Mastic to 13mm
minimum depth
Backing Rod
2 or 3 layers
GYPROCK
FYRCHEK
plasterboard
Stud
1, 2 or 3 layers
GYPROCK
FYRCHEK
plasterboard
Z5
FRL 90/90/90
16mm GYPROCK
FYRCHEK
plasterboard
13mm GYPROCK
FYRCHEK
plasterboard
13mm GYPROCK
FYRCHEK plasterboard
Stud
GYPROCK
Staggered
Stud Clip
Stopping bead
and set finish
1.0mm steel strip
with 50mm min.
overlap
400mm
max.
75mm max.
Rebate 12mm
wide max. x 5mm
deep max.
12mm MDF skirting
with 1.0mm steel strip
behind. Separately fix
skirting and steel with
two screws per stud
Staggered
stud profiles
NOTE: Wall/ceiling
junction may be
finished square, with
stopping bead or with
cornice.
15mm
Continuously fill gap
with CSR Gyprock
Fire Mastic to depth
of first layer
GYPROCK
plasterboard
Staggered
stud profiles
bottomed in
track/angle
GYPROCK
plasterboard
GYPROCK
Staggered
stud clip
16mm GYPROCK
FYRCHEK
plasterboard
75mm max. to
first fastener.
Stud
16mm GYPROCK
FYRCHEK
plasterboard
Stopping bead
and set finish
1.0mm steel strip
with 50mm min.
overlap
400mm
max.
Rebate 10mm
wide max. x 6mm
deep max.
12mm MDF skirting
with 1.0mm steel strip
behind. Separately fix
skirting and steel with
two screws per stud
75mm max.
15mm
Continuously fill gap
with Gyprock Fire
Mastic/FB1 to depth
of first layer
Staggered
studs
NOTE: Wall/ceiling
junction may be
finished square, with
stopping bead or with
cornice.
GYPROCK
plasterboard
GYPROCK
plasterboard
75mm max. to
first fastener.
Z6
Extent of FRL
600mm max.
100mm max.
Track
100mm max.
to first track
fixing
Set corners
Bottom track
fastened to floor
with metal fasteners
Stud
GYPROCK
FYRCHEK
plasterboard
Fix at 600mm
max. centres
along track
Metal track
fixings
Track
Track
100mm max.
Metal track
fixings
ax
Track
10
0m
Track
100mm max.
to first track
fixing
Metal track
fixings
GYPROCK
FYRCHEK
plasterboard
Fix at 600mm
max. centres
along track
Track
Metal track
fixings
GYPROCK
FYRCHEK
plasterboard
Z7
GYPROCK
plasterboard
64 mm x 0.75mm
BMT Steel stud
Attach with
plasterboard
laminating screws at
600 mm centres
Tape and
set corners
CSR Gyprock
Staggered Studs
and Clips
Finish corners
as required
Z8
15-20mm
gap
Finish surface
as per external angles
Additional stud to
form control joint
Stud in
normal
position
RONDO P35
Control Joint
RONDO P35
Control Joint
or alternative
Backing Rod
non fire rated 22mm dia.
Tracks discontinuous
at control joint
Additional stud to
form control joint
15mm min.
Finish surface
as per external angles
Finish surface
as per external angles
Backing Rod
non fire rated
22mm dia. for
acoustic integrity
15-20mm
gap
Finish surface
as per external angles
RONDO P35
Control Joint
15mm min.
Stud in
normal
position
GYPROCK
Plasterboard
RONDO P35
Control Joint
15-20mm
gap
Additional stud to
form control joint
Stud in
normal
position
15-20mm
2 x 16mm GYPROCK
FYRCHEK plasterboard
20mm min.
RONDO P35
Control Joint
or alternative
Backing Rod
non fire rated
22mm dia.
Stud in
normal
position
Tracks discontinuous
at control joint
Additional stud to
form control joint
Cemintel
Wallboard
Backing Rod
non fire rated
22mm dia. for
acoustic integrity
15-20mm
gap
13mm GYPROCK
FYRCHEK plasterboard
20mm min.
Finish surface
as per external angles
Finish surface
as per external angles
15-20mm
2 x 13mm GYPROCK
FYRCHEK plasterboard
Stud in normal
position
RONDO Stopping
Bead and set over
Additional stud to
form control joint
Track
Do not fix
plasterboard
to end stud
10mm
100 to 150mm
13 or 16mm GYPROCK
FYRCHEK plasterboard
Tracks discontinuous
at control joint
10mm
Cemintel
Wallboard
Z9
Continuous back-block of
GYPROCK FYRCHEK same
thickness as ceiling sheet
60 to 70mm
Furring
Channel
Furring Channel
RONDO P35
Control Joint
with set finish
15 to 20mm gap
1 layer GYPROCK
FYRCHEK
plasterboard screw
fixed to furring
channel each side of
joint at 200mm max.
centres
RONDO P35
Control Joint
with set finish
15 to 20mm gap
GYPROCK FYRCHEK
plasterboard fixed to
N140 Track at 200mm
max. centres
Continuous back-block of
GYPROCK FYRCHEK same
thickness as ceiling sheet
Fix one side of back-block
with laminating screws at
600mm max. centres or
plaster based adhesive
Furring
Channel
60 to 70mm
Furring Channel
RONDO P35
Control Joint
with set finish
15 to 20mm gap
2 layers GYPROCK
FYRCHEK
plasterboard screw
fixed to furring each
side of joint at 200mm
max. centres
RONDO P35
Control Joint
with set finish
15 to 20mm gap
GYPROCK FYRCHEK
plasterboard fixed with
laminating screws to
layer above at 200mm
max. centres
Continuous back-block of
GYPROCK FYRCHEK same
thickness as ceiling sheet
Fix one side of back-block
with laminating screws at
600mm max. centres or
plaster based adhesive
Furring
Channel
each side
of joint
RONDO P35
Control Joint
with set finish
Furring Channel
15 to 20mm gap
3rd layer of GYPROCK
FYRCHEK plasterboard
fixed with laminating screws
at 200mm max. centres
Z10
RONDO P35
Control Joint
with set finish
15 to 20mm gap
Continuously and
completely fill gap
with CSR Gyprock
Fire Mastic
1 layer GYPROCK
FYRCHEK plasterboard
continuous across joint
Laminating screws at
200mm max. centres
RONDO
Stopping Bead
with set finish
10 to 12mm gap
Continuously and
completely fill gap
with CSR Gyprock
Fire Mastic
2 layers GYPROCK
FYRCHEK plasterboard
continuous across joint
Laminating screws at
200mm max. centres
RONDO
Stopping Bead
with set finish
Laminating screws at
200mm max. centres
Trimmers at 450mm
max. centres
Joist
Joist
RONDO P35
Control Joint
with set finish
200mm min.
GYPROCK
FYRCHEK
plasterboard
15 to 20mm gap
300mm min.
Joist
200mm min.
GYPROCK
FYRCHEK
plasterboard
15 to 20mm gap
RONDO P35
Control Joint
with set finish
Laminating screws at
200mm max. centres
Laminating screws at
200mm max. centres
Trimmers at 450mm
max. centres
300mm min.
Joist
RONDO P35
Control Joint
with set finish
200mm min.
15 to 20mm gap
Joist
GYPROCK
FYRCHEK
plasterboard
Joist
200mm min.
15 to 20mm gap
RONDO P35
Control Joint
with set finish
Aluminium Foil under joist,
300 x 150 x 0.15mm
GYPROCK
FYRCHEK
plasterboard
Z11
Step 1:
Step 2:
Choose a suitable
ceiling perimeter
framing detail.
Refer to
FIG Z101
to
FIG Z130
Choose a suitable
perimeter caulking
detail.
Refer to
FIG Z140
to
FIG Z147
FIG: Z102
600mm max.
Ceiling Joist
Angle may be
required as backing
for caulking
1 or 2 layers of
GYPROCK FYRCHEK
GYPROCK
Plasterboard
1 or 2 layers of
GYPROCK FYRCHEK
Packer to suit
Non fire
rated or
lower
rated
timber
wall
system
FIG: Z103
FIG: Z104
600mm max.
200mm max.
Ceiling Joist
1, 2 or 3 layers of
GYPROCK FYRCHEK
Z12
GYPROCK
Plasterboard
1, 2 or 3 layers of
GYPROCK FYRCHEK
Non fire
rated or
lower
rated
timber
wall
system
CEILING PERIMETER FRAMING AT JUNCTION WITH FIRE RATED STEEL FRAMED WALL
FIG: Z111
FIG: Z112
600mm max.
200mm max.
1, 2 or 3 layers of
GYPROCK FYRCHEK
Rondo Wall Track fixed at
600mm max. centres with
metal fasteners
1, 2 or 3 layers of
GYPROCK FYRCHEK
Fire rated
wall system
Refer to FIG Z100
FIG: Z113
FIG: Z114
600mm max.
1, 2 or 3 layers of
GYPROCK FYRCHEK
FIG: Z115
FIG: Z116
200mm max.
600mm max.
1, 2 or 3 layers of
GYPROCK FYRCHEK
Steel Angle fixed at
600mm max. centres with
metal fasteners
Refer to FIG Z100
1, 2 or 3 layers of
GYPROCK FYRCHEK
1, 2 or 3 layers of
GYPROCK FYRCHEK
Fire rated
wall system
Z13
FIG: Z122
1, 2 or 3 layers of
GYPROCK FYRCHEK
Masonry
wall system
600mm max.
1, 2 or 3 layers of
GYPROCK FYRCHEK
FIG: Z123
FIG: Z124
600mm max.
Refer to FIG Z100
Ceiling Joist
1, 2 or 3 layers of
GYPROCK FYRCHEK
Packer to suit
Continuous strip of 16mm
GYPROCK FYRCHEK
1, 2 or 3 layers of
GYPROCK FYRCHEK
FIG: Z125
FIG: Z126
600mm max.
Refer to FIG Z100
Ceiling Joist
1, 2 or 3 layers of
GYPROCK FYRCHEK
Angle may be
required as backing
for caulking
Wire Mesh (galvanised)
nailed to wall plate
Render
Z14
Packer to suit
Masonry
wall system
1, 2 or 3 layers of
GYPROCK FYRCHEK
FIG: Z127
FIG: Z128
600mm max.
Ceiling Joist
1, 2 or 3 layers of
GYPROCK FYRCHEK
Angle may be
required as backing
for caulking
Gyprock Masonry Adhesive
(large daubs to bridge cavity)
Packer to suit
Masonry
wall system
GYPROCK
Plasterboard CD
1, 2 or 3 layers of
GYPROCK FYRCHEK
FIG: Z129
FIG: Z130
600mm max.
200mm max.
Masonry
wall system
1, 2 or 3 layers of
GYPROCK FYRCHEK
1, 2 or 3 layers of
GYPROCK FYRCHEK
Rondo Wall Track fixed at
600mm max. centres with
metal fasteners
Refer to FIG Z100
Z15
10mm
min.
Wall System
Wall System
FIG: Z140
Backing rod
(non fire rated)
Continuously fill gap at
edge of sheet with
CSR Gyprock Fire Mastic
min. 16mm depth
FIG: Z141
FIG: Z144
Wall System
Wall System
FIG: Z145
Wall System
FIG: Z142
Timber moulding
Continuously fill gap at
edge of all sheets with
Vermiculite plaster
FIG: Z146
FIG: Z147
70mm max.
Masonry
wall system
Z16
Wall System
6mm gap
max.
Service Penetrations
Acoustic Performance
The acoustic performance of walls and ceilings can be
reduced by penetrations for plumbing, electrical switches,
light fittings, etc. For construction that is acoustically
sensitive, it is recommended that, wherever possible, such
penetrations are avoided. In other cases, rated proprietary
sealants and products should be used.
There is a wide range of services and materials that may
be required to penetrate sound rated walls and ceilings,
and in varied configurations and concentrations. CSR
recommends that an acoustic engineer be consulted for
advice on all details for projects with specific acoustic
objectives.
Fire and acoustic rated switch boxes are available from
manufacturers such as PROMAT, CLIPSAL and HPM to
assist in maintaining the acoustic integrity of wall systems.
Wall system CSR 075 has been tested without penetrations,
and also in the configuration shown in FIG Z201, using
PROMAT fire rated switch boxes. An acoustic performance
of Rw52 was recorded in both cases. (CSIRO Nth Ryde Test
N HAS 029). Designers should contact the manufacturer
for performance in other walls and configurations. CSR
recommends that wherever electrical penetrations are
made, 75mm CSR Bradford Glasswool Partition batts be
incorporated in the wall cavity to assist acoustic integrity.
Refer to FIG Z201 & Z203.
Gyprock
Silencer
Gyprock
Silencer
Gyprock
Silencer
Mixer
only
Water supply
Concrete Slab
Power supply
Z17
Deflection
gap
Silencer inside
track and held by
Rondo clip
GYPROCK FYRCHEK
plasterboard (number of
layers and thickness in
accordance with wall
system specifications)
Head
Track
Fire Performance
Gyprock
Silencer
Base Track
or Angle
Gyprock
Silencer
50mm
200mm
50mm
Z18
Penetration Details
FIG Z204: TYPICAL ELECTRICAL SERVICES
INSTALLATION WITH GYPROCK SILENCER
GYPROCK
Plasterboard CD
General purpose
power outlet
CSR Gyprock
Fire Mastic
thickness 15mm
min.
Where wall
system has only
one layer of
GYPROCK
FYRCHEK,
provide extra
200mm wide
border and fix
with laminating
screws
20mm
25mm
150mm max.
Gyprock
SecurityWall
Panel
CSR Gyprock
Fire Mastic
GYPROCK FYCHECK
Plasterboard
Gyprock
Silencer
Steel or copper
metal pipe
system, 1.5mm
min. wall
thickness
2 layer
GYPROCK
FYRCHEK
wall system
GYPROCK
FYCHECK MR
Plasterboard
GYPROCK
AQUACHEK
plasterboard
Mixer
tap set
Gyprock
Silencer
GYPROCK FYRCHEK
fixed to studs and
noggings around cutout
at 150mm maximum
centres
Z19
GYPROCK
FYRCHEK
Electrical
Cables
Cable
Tray
PVC pipe
Proprietary
Fire Collar
IBS strips
50 x 19mm
16mm
16mm
16mm
PROMAT
Fyre Collar
fixed to support
framing
GYPROCK
FYRCHEK
wall lining
Cable Tray
PVC Pipe
PROMAT
Fyre Collar
fixed to support
framing
IBS strips
50 x 19mm
25mm
GYPROCK
FYRCHEK
1 or 2
layers
10-30mm
CSR Gyprock
Fire Mastic
Z20
FIG Z212: INSTALLATION DETAIL FOR FIRE DAMPER IN STUD WALL SYSTEM
Appraisal: PROMAT FCO 2106
Boxed studs
Deflection Head
Track fixed to studs
Promaseal IBS backing
rod 20% larger diameter
than gap (gap 15-30mm).
Promaseal Acrylic Mastic
over (5mm min. depth)
Caulk between
plasterboard and
damper body sides
with Promaseal
Acrylic Mastic 5mm
min. depth
Mechanical fire
damper tested and
approved for
AS1530.4
1 or 2 layers
GYPROCK
FYRCHEK
Plasterboard as
per FRL
Damper seal angles
75 x 50 x 1.2mm MS
Boxed studs
Deflection Head
Track fixed to studs
Sheetmetal
Riser
Sheetmetal ductwork
Perimeter of duct sealed with
Lorient Intumescent Mastic
Z21
FIG Z214: INSTALLATION DETAIL FOR FIRE DAMPER IN SHAFT WALL SYSTEM
FRL /120/. Appraisal: CSIRO FCO 2109
1500mm max.
J-Track
Mechanical fire
damper tested and
approved for
AS1530.4
1400mm max.
Steel studs
at 600mm
centres
Rondo angles
mechanically
fixed to studs
GYPROCK
FYRCHEK
plasterboard
Steel studs at
600mm centres
Proprietary
intumescent
damper
Spigot to terminate
with break joint
Z22
Ceiling
suspension
system
Fire Damper
Floor Joist
Fire Damper
Frame
GYPROCK FYRCHEK
plasterboard layers
and thickness
appropriate for system
Trimmers
50 x 50mm min.
Air Diffuser
Volume Dampers
Furring Channel
Part N129
1 or 2 layers of GYPROCK
FYRCHEK plasterboard
Stirrup fabricated
from stud or furring
*Cup head bolts and N226 clips
85 x 7mm
*Light fitting
support
450mm
141mm
127mm
50 50
7mm
Two layers
16mm
GYPROCK
FYRCHEK
*Support
250 x 50 x 3mm
285mm
2 layer x 16mm
GYPROCK FYRCHEK
*Light trim
Z23
Wall Studs
IBS Strip
50 x 20mm
Timber
support
plate
520mm high
wire mesh
Shield,
200mm
diameter
1, 2 or 3 layers
of GYPROCK
FYRCHEK
plasterboard
6mm
15mm min.
100mm max.
Gyprock Fire
Mastic
Wafer head
screw
Wall Studs
Rondo Nogging
Bracket No.501
PVC Pipe
Wafer head
screw
1, 2 or 3 layers
of GYPROCK
FYRCHEK
plasterboard
Fire collar
fixed to
support
framing
Z24
Section IN
Index
Contents
Index to Systems
IN2 IN3
IN1
Page N
System N
Page N
System N
Page N
System N
Page N
System N
Page N
005
B9
126
B43
248
B36
362
C13
535
D15
010
B9
127
B43
249
B36
363
C13
540
D12
011
B9
128
B43
250
B17
364
C13
541
D12
015
B9
129
B43
255
B18
368
C14
542
D12
025
B9
131
B14
257
E16
369
C14
543
D12
032
B9
132
B15
258
E16
370
C14
544
D13
033
B10
135
B14
259
E16
371
C14
545
D13
035
B10
136
B34
260
E16
372
C14
548
D12
038
B11
137
B34
261
E16
375
C9
549
D13
039
B10
138
B34
262
E16
380
C9
550
C10
040
B11
139
B34
263
E17
386
C20
551
D13
043
B13
140
B35
264
E17
387
C20
553
C10
044
B13
141
B35
265
E17
388
C20
555
C10
045
B13
142
B35
266
E17
389
C20
556
C11
046
B13
143
B35
267
E17
390
C21
557
E22
048
B13
150
B15
275
B19
391
C21
559
E22
049
B13
152
B15
280
B19
392
C21
560
E22
050
B11
153
B15
284
B27
393
C21
561
E22
055
B11
155
B15
285
B27
403
C18
562
E22
060
B28
165
B40
290
B25
406
C18
563
E23
061
B28
166
B39
291
B25
407
C18
564
E23
062
B28
167
B40
292
B25
410
C18
565
E23
065
E31
168
B40
293
B25
411
C18
566
E23
066
E31
170
B41
294
B26
414
C19
567
E23
067
E31
171
B41
295
B26
415
C19
575
C12
068
E31
175
B16
296
B27
419
C19
579
C11
069
E31
178
B41
297
B26
422
C15
580
C12
070
E32
179
B41
298
B27
425
C15
582
C12
071
E32
180
B16
305
C6
430
C16
600
B10
072
E32
184
B45
310
C6
450
C16
601
B10
073
E32
185
B45
311
C6
455
C16
605
B10
075
B12
186
B45
315
C6
457
E20
606
B11
080
B12
187
B45
320
C6
458
E20
610
B12
085
B30
192
B46
322
C6
459
E20
611
B12
086
B30
193
B46
325
C7
460
E20
613
B12
089
B30
195
B46
326
C7
461
E20
614
B12
090
B30
196
B46
327
C7
462
E20
615
B11
091
B30
204
B17
330
C7
463
E21
630
B15
092
B31
206
B18
335
C7
464
E21
631
B14
093
B31
207
B17
337
E18
465
E21
632
B14
100
B23
208
B17
339
E18
466
E21
652
C9
101
B23
212
B19
340
E18
467
E21
653
C8
102
B23
216
B19
341
E18
475
C17
660
C8
103
B23
217
B18
342
E18
480
C17
661
C15
110
B14
218
B18
343
E19
493
C31
662
C15
111
B24
222
B20
344
E19
494
C31
663
C16
113
B24
223
B20
345
E19
496
C31
664
C16
114
B24
225
B20
346
E19
498
C31
665
C9
115
B24
226
B20
347
E19
526
D14
666
C16
118
B42
230
B21
350
C8
527
D14
667
C9
119
B42
231
B21
352
C8
528
D15
670
C17
120
B42
235
B21
354
C7
530
D14
671
C17
121
B42
240
B22
354
C8
531
D14
672
C17
122
B42
241
B22
355
C8
532
D14
674
C10
123
B42
243
B22
360
C13
533
D14
675
C10
125
B14
244
B22
361
C13
534
D15
677
C10
IN2
System N
Page N
System N
Page N
System N
Page N
System N
Page N
System N
Page N
678
C11
816
E9
876
E27
680
C11
817
E9
877
E33
959
E18
FP62
G14
967
B33
FP63
681
C11
818
E9
878
G14
E33
968
B33
FP75
682
C11
819
E9
G15
880
E33
969
B33
FP80
690
C28
820
G16
E7
885
E8
970
B32
FP82
693
C28
G16
821
E10
886
E8
971
B32
FP84
694
G17
C29
822
E11
888
E8
977
B32
FP86
G17
695
C29
823
E10
890
E37
981
E34
FP88
G18
696
C28
824
E10
891
E30
982
E34
G17
697
C29
825
E11
892
E30
983
E34
698
C29
826
E11
893
E30
985
E34
722
D20
827
E11
894
E30
986
E34
723
D20
828
E11
896
E30
987
E35
724
D20
829
E11
898
E30
992
E35
730
D19
831
E12
900
C22
993
E35
731
D19
832
E12
901
C22
994
E35
732
D19
833
E12
902
C24
995
E35
FP90
HEBEL
1000/1001
HEBEL
1006/1007
HEBEL
1030/1031
HEBEL
1032/1033
HEBEL 1302
E35
HEBEL 1303
D18
B52
HEBEL 1304
D18
B48
HEBEL 1305
D18
B48
HEBEL 1306
D18
HEBEL 1400
C25
737
738
739
760
D6
D8
D8
D6
834
835
836
837
E12
E13
E13
E13
903
905
905
906
C24
C24
C30
C22
997
EC031
EC105
EC110
D16
D17
D16
D17
D18
761
D6
838
E13
906
C24
EC115
B48
762
D6
839
E13
907
C22
EC205
B49
Hebel 1404
B44
B49
HEBEL 1600
E36
E36
763
D7
841
E14
908
C22
EC210
764
D7
842
E26
909
C22
EC215
B49
HEBEL 1635
765
D7
843
E26
911
C23
EC220
B50
SS01
F4
766
D7
844
E27
912
C23
EC225
B51
SS02
F4
767
D8
845
E14
920
C26
EC230
B51
SS04
F4
768
D8
846
E14
921
C27
EC305
B48
SS08
F5
769
D8
847
E15
923
C26
EC310
B49
SS10
F5
774
D9
848
E15
924
C26
EC315
B49
SS11
F5
775
D9
849
E15
925
C26
EC320
B50
SS12
F5
776
D10
850
E28
927
C26
EC325
B51
SS13
F5
777
D10
851
E28
928
C27
EC605
B48
SS17
F5
778
D11
852
E28
932
B39
EC615
B49
SS18
F6
779
D11
853
E28
933
B38
EC620
B48
SS19
F6
780
D9
854
E28
934
B38
FP01
G3
SS20
F6
781
D9
855
E29
935
B39
FP02
G3
SS21
F6
783
D10
856
E29
936
C30
FP03
G4
SS22
F6
784
D10
857
E29
937
B44
FP04
G4
SS23
F6
787
D11
858
E29
940
B37
FP10
G5
SS30
F7
788
D11
859
E29
941
B37
FP11
G5
SS31
F7
795
D21
860
E31
941
B37
FP16
G6
SS32
F7
796
D21
862
E26
945
B29
FP17
G6
SS34
F7
797
D21
863
E26
946
B29
FP20
G7
SS38
F7
798
D21
864
E26
947
B29
FP21
G7
SS39
F7
805
E7
865
E33
948
E24
FP25
G8
SS40
F8
806
E7
866
E33
949
E24
FP26
G8
SS41
F8
807
E7
867
E27
950
E24
FP31
G9
SS42
F8
808
E7
868
E26
951
E24
FP35
G9
SS44
F4
809
E7
870
E25
952
E24
FP40
G10
SS45
F4
810
E8
871
E25
953
E24
FP45
G10
SS46
F4
811
E8
872
E33
954
E25
FP50
G11
812
E8
873
E33
955
E25
FP55
G12
814
E9
874
E27
956
E25
FP60
G13
815
E9
875
E27
958
E22
FP61
G13
IN3
Contact Details
Disclaimer
This guide is current at September 2011 and supersedes
all previous versions of the Fire and Acoustic Design Guide.
CSR has taken all reasonable care in producing this guide,
however CSR makes no representations or warranties,
express or implied, as to the accuracy, reliability or
completeness of the guide, and disclaims all liability, direct
or indirect (and whether or not arising out of the negligence,
default or lack of care of CSR) for any loss or damage
(whether foreseeable or not) suffered by the recipient or
any other person arising out of, or in connection with, any
use or reliance by any of them on the guide. Liability which
cannot legally be excluded is limited to the maximum extent
possible.
Information including acoustic and fire rating has been
sourced from recognised third parties and is current at
the time of printing. Systems, Standards and Building
Codes are subject to change. To ensure the information
is current, check the websites www.gyprock.com.au and
www.cemintel.com.au or contact CSR.
The guide is copyright CSR Limited (A.B.N 90 000 001 276)
and its related bodies corporate (CSR). Copyright 2011.
www.gyprock.com.au
CSR Cemintel Web Site
www.cemintel.com.au
CSR Gyprock Sales Support
Telephone: 13 17 44
Facsimile: 1800 646 364
CSR designLINk Technical Support Service
Telephone: 1800 621 117
Facsimile: 1800 069 904
Email: [email protected]
New South Wales and ACT
376 Victoria Street, Wetherill Park NSW 2164
Queensland
768 Boundary Road, Coopers Plains QLD 4108
Victoria
277 Whitehall Street, Yarraville VIC 3013
South Australia
Lot 100 Sharp Court, Mawson Lakes SA 5095
Western Australia
21 Sheffield Road, Welshpool WA 6106
Tasmania
PO Box 61, Glenorchy TAS 7010
Northern Territory
Cnr Stuart Hwy & Angliss St, Berrimah NT 0828
The following are trade marks of CSR Limited and are under license. CSR,
Gyprock, Supaceil, Soundchek, Aquachek, Impactchek, Superchek,
Fyrchek, FyrchekMR, ECO8, Bradford, designLINK, Cemintel,
SeminSeal, RendaLine, StrataWall, ExpressWall.
Publication GYP500.BMS9600.1111