SVS.435 Steam Turbine Control Upgrades

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4
At a glance
Powered by AI
The key takeaways are the benefits of upgrading mechanical steam turbine governors to electronic governing systems, such as improved efficiency, reduced maintenance costs, and real-time performance data.

Some benefits of upgrading with an electronic governing system include more precise speed control, fewer wearing parts, improved production from driven equipment through enhanced steam management, and real-time turbine operating parameter data.

Elliott Group offers integrated process control systems in partnership with Tri-Sen Systems, as well as single-valve 310SV and self-powered digital TS300 governors.

SERVICES

Steam Turbine Control Upgrades

Improved Systems
Every day a turbine is operated without an upgraded governing system is potentially another day of reduced
efficiency and lost profits. Mechanical governors are sensitive to ambient conditions and have components
that wear, experience fatigue and failure requiring service and excessive downtime and maintenance costs. To
improve the process control stability or reduce plant operations and maintenance costs, upgrade your steam
turbine governor with an electronic governing system. An electronic governor can provide precise speed control
with fewer wearing parts than an equivalent mechanical governor. The electronic governor may also improve
plant production from driven equipment through enhanced steam management while providing real-time data on
turbine operating parameters. An electronic governing system can provide instantaneous data on the turbines
performance and speed while requiring minimal power and eliminating cumbersome mechanical attachments.
As the OEM, Elliott Group has the technical capabilities to define, scope, supply and install electronic governor
upgrades on a wide variety of steam turbines operating in many different applications. Any customer looking to
upgrade will have a governor system tailored to their specific needs to guarantee satisfaction, ensure a reliable
installation process and maximize turbine control reliability. By deciding to make an upgrade now, Elliott can plan
ahead to make changes during your next planned overhaul.

Integrated Process Controls


Elliott customers gain a full scope of rotating machinery excellence integrated with advanced turbomachinery
controls in one package. Elliott Group and Tri-Sen Systems strategic alliance provides Tri-Sen control systems
as standard offerings with all Elliott compressors and turbines, in both new project and installed equipment.
Customers benefit from a single-point of contact no longer addressing software issues, turbomachinery
component questions and retrofit applications separately. Additional benefits include Elliott Global Services
enhanced capability to upgrade and modify aging controls plus site evaluations that can provide anticipated
efficiency gains as well as financial justification for a governor upgrade.

Single-Valve Governor 310SV


This fully integrated and configurable controller is designed to handles start up and protect API-611 or noncritical
API-612 single-valve mechanical drive steam turbines. In addition to speed control, the 310SV provides cascade
control for regulating process variables such as suction/discharge pressure flow or inlet discharge steam pressure.
310SV Governor
Pneumatic Direct-connected Trip
Timing gear with 6 MPUs
Valtek Logix 3200MD positioner
Turbo-Sentry voting overspeed
detection

Redundant Control System


(RCS) controls pneumatic
air supply for trip-system
cylinder

Self-Powered Digital Governor TS300


The TS300 is a compact, self-powered digital controller providing automatic startup and speed control for
API-611 single-valve general-purpose steam turbines driving a mechanical load. Options include aluminum or
stainless steel explosion-proof housing. The TS300 is available in either self-powered with a battery backup or
external power mode.

No Electrical Power
In self-powered mode, the power
is derived from the high-output
magnetic pickups or sourcing analog
input.
TS300 governor with pneumatic
start-up assist
Lockable junction box with push
buttons for field operations
MG10 with 3 Dynalco MPUs
Mechanical trip
Low-powered I/P
10-year LiON battery
Valtek Beta Positioner

Electrical Power
TS300 governor
Pneumatic Direct-connected trip
system
Elliott standard timing gear with 6 MPUs
Valtek Logix 3200MD positioner
Redundant Control System (RCS) controls pneumatic air supply for
trip-system cylinder
MG10

Elliott Group is a global leader in the


design, manufacture and service of
technically advanced centrifugal compressors, steam turbines, power recover expanders and axial compressors
used in the petrochemical, refining, oil
& gas and process industries, as well as
in power applications. Elliott Group is a
wholly owned subsidiary of Ebara Corporation, a major industrial conglomerate headquartered in Tokyo, Japan.

901 North Fourth Street


Jeannette, PA 15644-1473
Telephone: 724-527-2811
Fax: 724-600-8442
Email: [email protected]
www.elliott-turbo.com

2013 Elliott Group

SVS.435.01