Atp Procedure

Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 26
At a glance
Powered by AI
The document outlines acceptance test procedures for an OLT including equipment tests, basic configuration tests, and tests for GPON OLT voice and data services.

The document provides test procedures to verify the functionality of an OLT including visual inspections, management access, board management, basic configuration, and configuration of voice and data services over GPON.

The steps include creating a GPON line profile, T-CONT, GEM port, gem mapping, ONT service profile, adding an ONT, and verifying the ONT information.

OLT MA5600T

Acceptance Test Guide

OLT ACCEPTANCE TEST PROCEDURE


For

OLT SMT PROJECT - Batch 1

PT. SERPONG MAS TELEMATIKA


OLT Site Name : SINARMAS LAND PLAZA MMR-1

Document Prepared by Huawei and Approved by SMT

Huawei Technologies Co., Ltd

OLT MA5600T

Acceptance Test Guide

ii

OLT MA5600T

Acceptance Test Guide

TABLE OF CONTENT
Table of Content

...............................................................................................................................................................i
T01 Equipment Test................................................................................................................................................1
T01-01 Visual Check........................................................................................................................................1
T01-0101 Hardware Installation..............................................................................................................1
T01-02 Maintenance & Management...............................................................................................................2
T01-0201 Serial Port Mode.....................................................................................................................2
T01-0202 Outband Telnet Mode..............................................................................................................2
T01-0203 Inband Telnet Mode................................................................................................................3
T01-03 Board Management Test......................................................................................................................3
T01-0301 Auto-finding & Confirming Service Board............................................................................3
T01-0302 Disabling/Enabling a PON Port..............................................................................................5
T01-0303 Resetting Boards.....................................................................................................................6
T01-0304 Rebooting The System............................................................................................................7
T02 Basic Configuration Test.................................................................................................................................7
T02-01 Admin Login........................................................................................................................................7
T02-02 Management VLAN Configuration.....................................................................................................7
T02-0201 Creating a VLAN....................................................................................................................7
T02-0202 Adding a VLAN to a Port.......................................................................................................8
T02-03 Management IP Configuration.............................................................................................................8
T02-0301 Creating an IP Address & Subnetmask...................................................................................8
T02-0302 Creating a Default Route........................................................................................................9
T02-04 Ping Reachability.................................................................................................................................9
T02-0401 IP Gateway Ping......................................................................................................................9
T02-0402 IP NMS Ping.........................................................................................................................10
T02-05 Saving the Configuration...................................................................................................................10
T03 Reliability Test...............................................................................................................................................11
T03-01 Switchover Test..................................................................................................................................11
T03-0101 Active/Standby Switchover of Control Boards.....................................................................11
T03-0102 Backup Protection of Power Boards.....................................................................................12
T03-02 Uplink Protection Test.......................................................................................................................13
T03-0201 Uplink Port 1+1 Backup.......................................................................................................13
T04 Service Function Test.....................................................................................................................................16
T04-01 Triple Play Test..................................................................................................................................16
T04-0101 Multiple Service Profile........................................................................................................16
T04-0102 GPON OLT HSI Service.......................................................................................................17
T04-0103 GPON OLT OTT Service......................................................................................................19
T04-0104 GPON OLT Voice Service....................................................................................................21

iii

OLT MA5600T

Acceptance Test Guide

iv

OLT MA5600T

Acceptance Test Guide

GPON OLT MA5600T


T01 Equipment Test
T01-01 Visual Check
T01-0101 Hardware Installation
Purpose

To check whether the cabinet installation meets the requirements

Network diagram

None

Prerequisite

The cabinet installation must be completed.

Procedure

Verify the quantity of all racks, equipments, cables & accessories.


Check the cabinet appearance.
Check the inside of the cabinet.
Check the cable suit.
Check whether the boards are properly installed & connected to optical fibers and user
cables.
Check the front panels of the boards.
Check the connections of the fuses, power cables and ground cables.
Check the cabinet door and the side panel.
Check the sub rack fan modules
Check all the labels for racks, equipments & cables.

Expected results

1.

In step 1, all the quantity are match with Bill of quantity

2.

In step 2, the cabinet appearance is clean without distortion, scratch, and rustiness.

3.

In step 3, there are no sundries in the cabinet, the bolts are fastened tightly, and no
component in the cabinet is rusty. In addition, the air filter is installed and in clean
condition.

4.

In step 4, the cable suit is complete and the spare cables are bundled properly.

5.

In step 5, the boards are properly installed & connected to optical fibers and
user cables.

6.

In step 6, the front panels are clean; the silk screen is consistent with the board
name and there is no scratch.

7.

In step 7, the fuses, power cables are connected properly and the cabinet is
grounded.

8.

In step 8, the cabinet door, the side panel, and the body of the cabinet are properly
grounded, and the cabinet door can be opened and closed easily.

9.

In step 9, the sub rack fan modules are running well

10. Racks, Equipments & cables are labeled properly


Remarks

SCUN = Control board, GBPD/GBPH = GPON board, X2CS = 10GE uplink board

OLT MA5600T

Acceptance Test Guide

T01-02 Maintenance & Management


T01-0201 Serial Port Mode
Purpose

To verify the maintenance function of the local serial port

Network diagram

None

Prerequisite

The MA5600T must be powered on and must work in the normal state.
The maintenance serial port of the main control card works in normal state.

Procedure

Expected results
Remarks

1.

Use the maintenance serial port cable to connect the maintenance serial port (com
port) of the main control card with one of the serial ports (usually serial port 1) of
the maintenance terminal.

2.

Run the HyperTerminal, enter the connection description, select the corresponding
serial port, and configure its property as follows: 9600bit/s for baudrate, 8 for data
bit, None for parity check, 1 for stop bit, and None for flow control.

3.

After finishing the configuration, use this serial port for connection.

4.

Enter the user name: huawei and the password: r00tw3rk#@! to log in the system.

5.

Run some commands.

The communication of the serial port is in good condition, the login is successful, and
the commands can be executed correctly.
The default baud rate of the maintenance serial port is 9600 bit/s.

T01-0202 Outband Telnet Mode


Purpose

To verify the maintenance function by Telnet session

Network diagram

None

Prerequisite

The MA5600T must be powered on and must work in the normal state.
The network interface card & IP address of the maintenance terminal has been properly
configured.

Procedure

1.

Connect ethernet cable from laptop to the m-eth port of the control card SCUN

2.

Run Telnet on the maintenance terminal using hyperterminal or other telnet


application

3.

Enter the IP address of the network port of main control card into the Telnet
window of the maintenance terminal.

4.

Log in, and run some commands.

Expected results

The connection is normal, the login is successful, and the commands can be executed
successfully.

Remarks

You can use the ping command to check whether the communication between the
maintenance terminal and the control card is in normal state.
The outband ip address of control card is: 192.168.1.1

OLT MA5600T

Acceptance Test Guide

T01-0203 Inband Telnet Mode


Purpose

To verify the maintenance function by inband telnet session

Network diagram

Prerequisite

The MA5600T must be powered on and must work in the normal state.
The OAM-IP address has been properly configured.

Procedure

1.

Log in to the MA5600T (OLT-1) using serial or outband mode.

2.

Run telnet command on the OLT-1 CLI to OLT-2 OAM ip-address using
hyperterminal or other telnet application

3.

After succeed logging into OLT-2, run some commands.

Expected results

The connection is normal, the login is successful, and the commands can be executed
successfully.

Remarks

You can use the ping command to check whether the communication 2 OLTs are in
normal state.
The OAM ip-address can be set based on the data provided, attached with this
document.

T01-03 Board Management Test


T01-0301 Auto-finding & Confirming Service Board
Purpose

To verify the function of automatically finding a service board and confirming the
service board

Network diagram

None

Prerequisite

The MA5600T must be powered on and must work in the normal state.
You must be logged in to the MA5600T from a PC through the upstream port in the
inband management mode or through the maintenance network port in the outband
management mode (telnet IP Address 192.168.1.1) or using console port. Ensure that the
MA5600T can be maintained normally.

Procedure

In the global config mode, run the display board 0 command to query the board status.
Insert a board into an idle slot.
In the global config mode, run the display board 0 command to query the board status.
Run the board confirm command to confirm the board inserted in step 1.
Run the display board 0 command to query the board status.

Expected results

In step 3, you can confirm that the board is automatically found and is in the auto-find
state.
3

OLT MA5600T

Acceptance Test Guide

In step 5, you can confirm that the board is in the normal state.
(Insert the normal command output here)
huawei> display board 0
Command:
display board 0
----------------------------------------------------------SlotID

BoardName Status

SubType0 SubType1 online/Offline

----------------------------------------------------------0
1

H802GPBD Normal

H802GPBD Normal

H802GPBD Normal

H802GPBD Normal

H802GPBD Normal

H802GPBD Normal

H802GPBD Normal

H802GPBD Normal

H801SCUN Active_normal

10

H801SCUN Standby_normal

11
12
13
14
15
16
17

H802GPBD Auto-find

18

H802GPBD Auto-find

19
20

Remarks

21

H801PRTE Normal

22

H801PRTE Normal

The auto-find state of the board can be queried through the display board 0 command
only after the MA5600T reports the alarm of automatically finding a board.

T01-0302 Disabling/Enabling a PON Port


4

OLT MA5600T

Acceptance Test Guide

Purpose

To verify the function of disabling and enabling a PON port

Network diagram

None

Prerequisite

The MA5600T must be powered on and must work in the normal state.
You must be logged in to the MA5600T from a PC through the upstream port in the
inband management mode or through the maintenance network port in the outband
management mode (telnet IP Address 192.168.1.1) or using console port. Ensure that the
MA5600T can be maintained normally.

Procedure

In the global config mode, run the interface gpon 0/1 command to enter the gpon
interface mode.
In the gpon interface mode, run command ont add 0 0 sn-auth 4857544353BA0409
omci ont-lineprofile-id 1 ont-srvprofile-id 1 to add an ONT to PON port 0.
Input command display port state 0 to query the state of pon port 0.
Run the shutdown 0 command to disable the port 0.
Run command display port state 0 to query the state of pon port 0.
Run the undo shutdown 0 command to enable the port 0.
Run command display port state 0 to query the state of pon port 0.

Expected results

In step 3, you can confirm that port is online


In step 5, you can confirm that port is offline
In step 7, you can confirm that the port is online
huawei(config-if-gpon-0/1)#shutdown 0
huawei(config-if-gpon-0/1)#display port state 0
---------------------------------------------------------------------------F/S/P

0/18/0

Optical Module status


Port state

Online

Offline

---------------------------------------------------------------------------huawei(config-if-gpon-0/1)#undo shutdown 0
huawei(config-if-gpon-0/1)#display port state 0
---------------------------------------------------------------------------F/S/P

0/18/0

Optical Module status


Port state

Online

Online

----------------------------------------------------------------------------

Remarks

T01-0303 Resetting Boards


Purpose

To check whether a board can return to the normal state after reset
5

OLT MA5600T

Acceptance Test Guide

Network diagram

None

Prerequisite

1.

The cabinet must be powered on and must work in the normal state.

2.

The MA5600T must work in the normal state.

1.

In the global config mode, run the display board 0 command to query the
service & control board status.

2.

Remove a service board and insert the service board back without powering
off the MA5600T, and then check whether the board is in the normal state
after reset.

3.

In the global config mode, run the display board 0 command to query the
service board status.

4.

Press the RESET button on the front panel of the control board to reset the
control board, and then check whether the control board recovers after reset.

5.

In the global config mode, run the display board 0 command to query the
control board status.

6.

Run the board reset command to reset a service board, and then check
whether the service board recovers after reset

7.

In the global config mode, run the display board 0 command to query the
service board status.

1.

In step 3, the service board is in the normal state.

2.

In step 4, the active control board will be switched-over to standby board.

3.

In step 5, the control board is in the normal state after reset.

4.

In step 7, the service board is in the normal state after reset.

5.

The OLT configuration doesnt change after board resetting.

Procedure

Expected results

Remarks

Board status is failed when service board is removed.


SCUN = Control board, GBPD/GBPH = GPON board, X2CS = 10GE uplink
board

T01-0304 Rebooting The System


6

OLT MA5600T

Acceptance Test Guide

Purpose

To check whether the MA5600T can be rebooted without errors

Network diagram

None

Prerequisite

1.

The cabinet must be powered on and must work in the normal state.

2.

The MA5600T must work in the normal state.

1.

In the global config mode, run the save command to save the existing
configuration

2.

In the global config mode, run the reboot system command to reboot the
MA5600T

1.

The MA5600T can be rebooted successfully without no errors

2.

The OLT configuration doesnt change after system rebooting

Procedure

Expected results

Remarks

T02 Basic Configuration Test


T02-01 Admin Login
Purpose

To verify the function of logging in the system using admin user

Network diagram

None

Prerequisite

The MA5600T must be powered on and must work in the normal state.

Procedure

1.

Access the MA5600T using serial or telnet mode

2. Enter the system using admin username: huawei and admin password:
r00tw3rk#@!
Expected results

The system can be accessed using admin account successfully

Remarks

T02-02 Management VLAN Configuration


T02-0201 Creating a VLAN
Purpose

To verify the function of creating a VLAN on the system

Network diagram

None

Prerequisite

The MA5600T must be powered on and must work in the normal state.

Procedure

1.

Enter the global config mode,

2.

Run the command: vlan 1000 smart to create vlan with id 1000 and type is smart

3.

Run the command: display vlan all

Expected results

In step 2, the vlan can be created successfully


In step 3, the vlan can be queried successfully
7

OLT MA5600T

Remarks

Acceptance Test Guide

The vlan can be set based on the data provided, attached with this document.

T02-0202 Adding a VLAN to a Port


Purpose

To verify the function of adding a vlan to a specified port

Network diagram

None

Prerequisite

The MA5600T must be powered on and must work in the normal state.
The vlan has been configured properly (refer to T02-0201)

Procedure

Expected results

1.

Enter the global config mode,

2.

Run the command: port vlan 1000 0/19 0 to to add vlan 1000 to the port 0/19/0

3.

Run the command: display port vlan 0/19/0

In step 2, the vlan can be added to the specified port (0/19/0) successfully
In step 3, the port vlan list can be queried successfully

Remarks

The vlan can be set based on the data provided, attached with this document.

T02-03 Management IP Configuration


T02-0301 Creating an IP Address & Subnetmask
Purpose

To verify the function of creating an ip address and its subnetmask

Network diagram

None

Prerequisite

The MA5600T must be powered on and must work in the normal state.
The vlan has been configured properly (refer to T02-0201)

Procedure

1.

Enter the global config mode,

2.

Run the command: interface vlan 1000

3.

Run the command: ip address 10.10.10.10 255.255.255.0

4. Run the command: display interface vlan 1000


Expected results

In step 3, the ip address & subnetmask can be created successfully


Instep 4, the ip address & subnetmask can be queried successfully

Remarks

The ip address can be set based on the data provided, attached with this document.
You can use 10.10.10.10 24 instead of 10.10.10.10 255.255.255.0

T02-0302 Creating a Default Route


Purpose

To verify the function of creating a default static route on the MA5600T


8

OLT MA5600T

Acceptance Test Guide

Network diagram

None

Prerequisite

The MA5600T must be powered on and must work in the normal state.
The ip address has been configured properly (refer to T02-0301)

Procedure

Expected results

1.

Enter the global config mode,

2.

Run the command: ip route-static 0.0.0.0 0.0.0.0 10.10.10.1

3.

Run the command: display ip routing-table

In step 2, the ip route can be created successfully


In step 4, the ip route can be queried successfully

Remarks

The ip address can be set based on the data provided, attached with this document.

T02-04 Ping Reachability


T02-0401 IP Gateway Ping
Purpose

To verify that the connectivity of MA5600T to the gateway is OK

Network diagram

Prerequisite

The MA5600T must be powered on and must work in the normal state.
The ip address & ip route has been configured properly (refer to T02-0302)

Procedure

1.

Enter the global config mode,

2.

Run the command: ping [gateway ip-address]

Expected results

The ip address of the gateway can be ping successfully without any losses

Remarks

The ip addresses can be set based on the data provided attached with this document.

T02-0402 IP NMS Ping


Purpose

To verify that the connectivity of MA5600T to the NMS is OK


9

OLT MA5600T

Acceptance Test Guide

Network diagram

Prerequisite

The MA5600T must be powered on and must work in the normal state.
The ip addresses & ip route has been configured properly (refer to T02-0302)

Procedure

1.

Enter the global config mode,

2.

Run the command: ping [nms ip-address]

Expected results

The ip address of the nms can be ping successfully without any losses

Remarks

The ip addresses can be set based on the data provided attached with this document.

T02-05 Saving the Configuration


Purpose

To verify that the configuration data can be sored in the MA5600T system

Network diagram

None

Prerequisite

The MA5600T must be powered on and must work in the normal state.
The configuration is exist

Procedure

Expected results

1.

Enter the global config mode,

2.

Run the command: save

3.

Run the command: reboot system

The configuration data can be saved successfully


The data will still exist after the system is switched off or rebooted.

Remarks

T03 Reliability Test


T03-01 Switchover Test
10

OLT MA5600T

Acceptance Test Guide

T03-0101 Active/Standby Switchover of Control Boards


Purpose

To verify the function of the active/standby switchover by removing/inserting the active


control board

Network diagram

None

Prerequisite

1.

The MA5600T must be configured with the active and standby control boards. The
active control board resides in slot 0/9, and the standby control board resides in slot
0/10. In addition, the MA5600T must be powered on, and must work in the normal
state.

2.

You must be logged in to the MA5600T from a PC through a serial port


(HyperTerminal), a network port (Telnet), or the U2000. Ensure that the MA5600T
can be maintained normally.

1.

Enter the global config mode.

2.

Run the display data sync state command to query the status of data

Procedure

synchronization between the active and standby control boards.


3.

When the data synchronization is complete, remove the active control board.

4.

Check the following information:


(1) Run the display board command to query the board information, and
check whether the original standby control board in slot 0/10 functions as
the active control board.
(2) Check whether the data is lost or modified after the switchover.
huawei>display board 0
Command:
display board 0
------------------------------------------------------------------------SlotID BoardName Status
SubType0 SubType1 Online/Offline
------------------------------------------------------------------------0
H801BIUA Failed
CKMA
Offline
1
2
3
4
5
6
7
8
9
H801SCUN standby_normal
10
H801SCUN Active_normal
11
12
13
14
15
16
17
18
11

OLT MA5600T

Acceptance Test Guide


19
H801GICE Normal
20
H801GICE Normal
21
22
------------------------------------------------------------------------huawei(config)# display data sync state
All of configuration data (such as data originated from user configuration)
synchronizes completely
All of basic operation data (such as device status data, operation log and
alarm, etc.) synchronizes completely
All of dynamic service data (data realtimely changing such as PSTN call data and
PPPOE call data,etc.) synchronizes completely.
User configuration data CRC check values of active and standby boards are
consistent

(3) Check whether services are in the normal state.


Expected results

When the data synchronization is complete, the active/standby switchover caused by


removing/inserting the active control board should not result in loss or modification of
data. The MA5600T can be maintained and services are in normal state after the
switchover.

Remarks

In step 3, if the data is not synchronized, run the duplicate command to duplicate the
data from the active control board to the standby control board. This ensures that the
data on the standby control board is consistent with the data on the active control board.

T03-0102 Backup Protection of Power Boards


Purpose

To verify the function of the protection switchover by removing/inserting one of power


board.

Network diagram

None

Prerequisite

The MA5600T must be configured with the active and standby power boards. The
power boards reside in slot 0/21, and 0/22. In addition, the MA5600T must be powered
on, and must work in the normal state.
You must be logged in to the MA5600T from a PC through a serial port
(HyperTerminal), a network port (Telnet), or the U2000. Ensure that the MA5600T can
be maintained normally.

Procedure

Enter the global config mode


Check whether both power boards are in normal state by running the display board
command.
Unplug one power board from the sub-rack.
Plug in the power board to the subrack after testing.

Expected results

In step 3, the power board will be in the failed


12

OLT MA5600T

Acceptance Test Guide

When one power is plugged out, the system power is still running well, and the
MA5600T is still powered on.
Remarks

T03-02 Uplink Protection Test


T03-0201 Uplink Port 1+1 Backup
Purpose

To verify the function of the upstream port 1+1 backup

Network
diagram

Prerequisite

Procedure

1.

All the devices must be properly connected according to the network diagram. The MA5600T
must work in the normal state.

2.

Upstream ports 0/19/0 and 0/19/1 must be connected to the upper-layer LAN switch through
the optical fibers. Port 0/19/0 must be the active upstream port.

3.

The IP address of the port on the LAN switch connected to the MA5600T must be configured
to xxx.xxx.xxx.xxx.

4.

A PC must be connected to an ONT port. The IP address of the PC must be xxx.xxx.xxx.xxx.

1.

Enter the global config & protect mode on MA5600T.

2.

Run the display protect-group command to query the information about the protection
group.
huawei(config-protect)#display protect-group
{ <cr>|pgid<U><0,63> }:
Command:
display protect-group
Failure: Protect group does not exist

3.

In the protection group mode, run the protect-group first 0/19/0 second 0/19/1 eth
workmode timedelay enable command to create an upstream protection group.

4.

Run the display protect-group command to query the information about the protection
13

OLT MA5600T

Acceptance Test Guide

group.
huawei(config-protect)#display protect-group
Command:
display protect-group
----------------------------------------------------------------------Group ID

:0

Admin State : enable


----------------------------------------------------------------------Member

Role

Operation

State

PeerMember

----------------------------------------------------------------------0/19/0

work

none

active

0/19/1

protect

none

standby

none
none

----------------------------------------------------------------------Total : 1
huawei(config-protect)#quit

5.

Display ONT info

huawei(config-if-gpon-0/5)#display ont info


{ portid<U><0,7> }:0
{all<K>|ontid<U><0,63> }: all
Command:
Display ont info 0 all
----------------------------------------------------------------------------F/S/P ONT
SN
Control Run
Config Match Protect
ID
flag
state state state side
--------------------------------------------------------------------------------------------------------------------------------------------------------F/S/P ONT-ID Description
--------------------------------------------------------------------------------------------------------------------------------------------------------In port 0/ 1/0 , the total of ONTs are: 0, online: 0

6.

Add an ONT to the devices. Run the service-port vlan command to add service ports,
and run the port vlan command to add the aggregation ports to the VLAN with the same
service port.

huawei(config)#ont-lineprofile gpon profile-id 5


huawei(config-gpon-lineprofile-5)#tcont 1 dba-profile-id 6
huawei(config-gpon-lineprofile-5)#gem add 1 eth tcont 1
huawei(config-gpon-lineprofile-5)#mapping-mode vlan
huawei(config-gpon-lineprofile-5)#gem mapping 5 0 vlan 10
huawei(config-gpon-lineprofile-5)#commit
14

OLT MA5600T

Acceptance Test Guide

huawei(config-gpon-lineprofile-5)#quit
huawei(config)#ont-srvprofile gpon profile-id 5
huawei(config-gpon-srvprofile-5)#ont-port pots 2 eth 4
huawei(config-gpon-srvprofile-5)#commit
huawei(config-gpon-srvprofile-5)#quit
huawei(config)#interface gpon 0/5
huawei(config-if-gpon-0/5)#ont add 0 sn-auth 0100000001 omci ont-lineprofile-id 15 ontsrvprofile-id 10
huawei(config-if-gpon-0/5)#display ont info
{ portid<U><0,7> }:0
{ all<K>|ontid<U><0,63> }: all
Command:
Display ont info 0 all
----------------------------------------------------------------------------F/S/P ONT
SN
Control Run
Config Match Protect
ID
flag
state state state side
----------------------------------------------------------------------------0/ 1/0 0 0100000001 active
offline initial initial no
----------------------------------------------------------------------------F/S/P ONT-ID Description
----------------------------------------------------------------------------0/ 1/0
0 ONT_NO_DESCRIPTION
----------------------------------------------------------------------------In port 0/ 1/0 , the total of ONTs are: 1, online: 0

7.

Ping LAN Switch continuously from PC.

8.

Remove the optical fiber from the current working GE port. After the switching of the
protection group, connect the optical fiber back to the GE port.

Expected
results

1.

In step 7, the PC can communicate with the LAN switch.

2.

In step 8, communication between the PC and the LAN switch is interrupted for a while, and
then the communication recovers.

Remarks

The optical ports in a protect group must be configured with auto-negotiation function.When the
protect group is in the forced mode, the switchover of the protect group does not occur and the
communication is interrupted if the Tx fiber is removed from the working port.

T04 Service Function Test


T04-01 Triple Play Test
T04-0101 Multiple Service Profile
15

OLT MA5600T

Purpose

Acceptance Test Guide

To verify the OLT support multiple service profile

Network diagram

Prerequisite
Procedure

1.

The cabinet must be powered on and must work in the normal state.

2.

The MA5600T must work in the normal state.

In the global config mode, run the interface gpon 0/1 command to enter the gpon
interface mode.
In the gpon interface mode, run command ont add 0 0 sn-auth
4857544353BA0409 omci ont-lineprofile-id 1 ont-srvprofile-id 1 to add an ONT
to PON port 0.
Run command :

service-port vlan 792 gpon 0/1/0 ont 0 gemport 792 multi-service user-vlan
792 rx-cttr 6 tx-cttr 6
service-port vlan 796 gpon 0/1/0 ont 0 gemport 796 multi-service user-vlan
796 rx-cttr 7 tx-cttr 7
service-port vlan 794 gpon 0/1/0 ont 0 gemport 794 multi-service user-vlan
794 rx-cttr 8 tx-cttr 8
Expected results

Remarks

1.

In step 3, the OLT can create more than 2 service profiles

2.

The bandwidth of the profile follows the rx-cttr & tx-cttr values

You can run the display service-port all to verify the service-port profile

T04-0102 GPON OLT HSI Service


Purpose

To verify the OLT can deliver the HSI (High Speed Internet) service.

16

OLT MA5600T

Acceptance Test Guide

Network diagram

Prerequisite

You must be logged in to the MA5600T from a PC through the upstream port in the
inband management mode or through the network port in the outband management
mode (telnet). Ensure that the MA5600T can be maintained normally.
All the devices must be properly connected according to the network diagram. The
MA5600T and the ONT must work in the normal state. The boards must be
registered successfully.
The ONT must be added to PON port 0/1/0, and must be configured and bound with
a DBA profile.
1.

Procedure

The service virtual ports carrying the data service must be configured.

Configure the HSI data service.

(1)

Enter the global config mode.

(2)

Run the ont-lineprofile gpon profile-id profile-id command to create a


GPON line profile.

(3)

In the ONT line profile mode, run the tcont tcont-list dba-profile-id
profile-id command to create a T-CONT.

(4)

Run the gemport add gem-index command to add a GEM port to the
PON port.

(5)

Run the gem mapping command to create mapping between the


GEM port and upstream packets.

(6)

Run the commit command to confirm the configuration and then run
the quit command to quit the ONT line profile mode.

(7)

Run the ont-srvprofile gpon command to enter the ONT service


profile mode.

(8)

In the ONT service profile mode, run the ont-port command to set
the information about the ONT port.

(9)

Run the commit command to confirm the configuration and then run
the quit command to quit the ONT service profile mode.

(10) Run the interface gpon frameid/slotid command to enter the GPON
mode.
(11) Run the ont add portid command to add an ONT.
huawei(config-if-gpon-0/1)#display ont info
{ portid<U><0,7> }:0
{ all<K>|ontid<U><0,63> }:all
17

OLT MA5600T

Acceptance Test Guide


Command:
display ont info 0 all
----------------------------------------------------------------------------F/S/P ONT
SN
Control Run
Config Match Protect
ID
flag
state state state side
----------------------------------------------------------------------------0/ 1/0 0 0100000001 active
offline initial initial no
----------------------------------------------------------------------------F/S/P ONT-ID Description
----------------------------------------------------------------------------0/ 1/0
0 ONT_NO_DESCRIPTION
----------------------------------------------------------------------------In port 0/ 1/0 , the total of ONTs are: 1, online: 0

(12) Run the quit command to return to the global config mode.
(13) Run the vlan 792 smart command to create smart VLAN 792.
(14) Run the service-port vlan 792 command to add a service port to
VLAN 792, and bind the network-side VLAN, GEM port, and userside VLAN.
(15) Run the port vlan 792 0/19 0 command to add upstream port 0/19/0
to VLAN 792 so that the upstream port and the service port are in the
same VLAN.
(16) Configure the BRAS. In the BRAS port mode, run the ip address
command to configure the IP address of the port and create a data
service channel.

Expected results

The user can access the HSI (High Speed internet) service normally.

Remarks

All the configuration parameters please follow to the data provided, attached with
this document.

T04-0103 GPON OLT OTT Service


Purpose

To verify the OLT can deliver OTT (TV/Video) service.

18

OLT MA5600T

Acceptance Test Guide

Network diagram

Prerequisite

You must be logged in to the MA5600T from a PC through the upstream port in the
inband management mode or through the network port in the outband management
mode (telnet). Ensure that the MA5600T can be maintained normally.
All the devices must be properly connected according to the network diagram. The
MA5600T and the ONT must work in the normal state. The boards must be
registered successfully.
The ONT must be added to PON port 0/1/0, and must be configured and bound with
a DBA profile.
2.

Procedure

The service virtual ports carrying the data service must be configured.

Configure the OTT data service.

(1)

Enter the global config mode.

(2)

Run the ont-lineprofile gpon profile-id profile-id command to create a


GPON line profile.

(3)

In the ONT line profile mode, run the tcont tcont-list dba-profile-id
profile-id command to create a T-CONT.

(4)

Run the gemport add gem-index command to add a GEM port to the
PON port.

(5)

Run the gem mapping command to create mapping between the


GEM port and upstream packets.

(6)

Run the commit command to confirm the configuration and then run
the quit command to quit the ONT line profile mode.

(7)

Run the ont-srvprofile gpon command to enter the ONT service


profile mode.

(8)

In the ONT service profile mode, run the ont-port command to set
the information about the ONT port.

(9)

Run the commit command to confirm the configuration and then run
the quit command to quit the ONT service profile mode.

(10) Run the interface gpon frameid/slotid command to enter the GPON
mode.
(11) Run the ont add portid command to add an ONT.
huawei(config-if-gpon-0/1)#display ont info
{ portid<U><0,7> }:0
{ all<K>|ontid<U><0,63> }:all
19

OLT MA5600T

Acceptance Test Guide


Command:
Displayont info 0 all
----------------------------------------------------------------------------F/S/P ONT
SN
Control Run
Config Match Protect
ID
flag
state state state side
----------------------------------------------------------------------------0/ 1/0 0 0100000001 active
offline initial initial no
----------------------------------------------------------------------------F/S/P ONT-ID Description
----------------------------------------------------------------------------0/ 1/0
0 ONT_NO_DESCRIPTION
----------------------------------------------------------------------------In port 0/ 1/0 , the total of ONTs are: 1, online: 0

(12) Run the quit command to return to the global config mode.
(13) Run the vlan 796 smart command to create smart VLAN 796.
(14) Run the service-port vlan 796 command to add a service port to
VLAN 796, and bind the network-side VLAN, GEM port, and userside VLAN.
(15) Run the port vlan 796 0/19 0 command to add upstream port 0/19/0
to VLAN 796 so that the upstream port and the service port are in the
same VLAN.
(16) Configure the BRAS. In the BRAS port mode, run the ip address
command to configure the IP address of the port and create a data
service channel.
Expected results

The user can watch the TV program service normally.

Remarks

All the configuration parameters please follow to the data provided, attached with
this document.

T04-0104 GPON OLT Voice Service


Purpose

To verify the OLT can deliver the voice service.

20

OLT MA5600T

Acceptance Test Guide

Network diagram

Prerequisite

You must be logged in to the MA5600T from a PC through the upstream port in the
inband management mode or through the network port in the outband management
mode (telnet). Ensure that the MA5600T can be maintained normally.
All the devices must be properly connected according to the network diagram. The
MA5600T and the ONT must work in the normal state. The boards must be
registered successfully.
The ONT must be added to PON port 0/1/0, and must be configured and bound with
a DBA profile.
3.

Procedure

The service virtual ports carrying the data service must be configured.

Configure the Voice data service.

(1)

Enter the global config mode.

(2)

Run the ont-lineprofile gpon profile-id profile-id command to create a


GPON line profile.

(3)

In the ONT line profile mode, run the tcont tcont-list dba-profile-id
profile-id command to create a T-CONT.

(4)

Run the gemport add gem-index command to add a GEM port to the
PON port.

(5)

Run the gem mapping command to create mapping between the


GEM port and upstream packets.

(6)

Run the commit command to confirm the configuration and then run
the quit command to quit the ONT line profile mode.

(7)

Run the ont-srvprofile gpon command to enter the ONT service


profile mode.

(8)

In the ONT service profile mode, run the ont-port command to set
the information about the ONT port.

(9)

Run the commit command to confirm the configuration and then run
the quit command to quit the ONT service profile mode.

(10) Run the interface gpon frameid/slotid command to enter the GPON
mode.
(11) Run the ont add portid command to add an ONT.
huawei(config-if-gpon-0/1)#display ont info
{ portid<U><0,7> }:0
{ all<K>|ontid<U><0,63> }:all
21

OLT MA5600T

Acceptance Test Guide


Command:
Display ont info 0 all
----------------------------------------------------------------------------F/S/P ONT
SN
Control Run
Config Match Protect
ID
flag
state state state side
----------------------------------------------------------------------------0/ 1/0 0 0100000001 active
offline initial initial no
----------------------------------------------------------------------------F/S/P ONT-ID Description
----------------------------------------------------------------------------0/ 1/0
0 ONT_NO_DESCRIPTION
----------------------------------------------------------------------------In port 0/ 1/0 , the total of ONTs are: 1, online: 0

(12) Run the quit command to return to the global config mode.
(13) Run the vlan 794 smart command to create smart VLAN 794.
(14) Run the service-port vlan 794 command to add a service port to
VLAN 794, and bind the network-side VLAN, GEM port, and userside VLAN.
(15) Run the port vlan 794 0/19 0 command to add upstream port 0/19/0
to VLAN 794 so that the upstream port and the service port are in the
same VLAN.
(16) Configure the BRAS. In the BRAS port mode, run the ip address
command to configure the IP address of the port and create a data
service channel.

Expected results

The user can make or receive a call normally.

Remarks

All the configuration parameters please follow to the data provided, attached with
this document.

22