A
X-01
X-02
X-03
5000
X-04
X-02
1800
1250
8T16-03
8T16-03
8T16-05
6Y12-06
6Y12-04
23T08-07-200
8T08-07-200
23T08-07-200
6Y12-01
6Y12-02
X-03
8T08-07-200
6Y12-01
X-04
1250
6Y12-06
6Y12-04
X-04
1800
1250
8T16-05
X-02
250x 600 BEAM SB01
X-03
5000
1250
X-01
X-01
NOTES:
1. All dimensions are in millimeters
2. Use class class 25 for bases &beams ,
class 25 for columns and 20 for the slab
3.Read this drawing in conjunction
with relevant Architectural drawings.
4. Minimum cover for concrete is:
a. Foundation = 50mm
b. Columns = 25mm
c. Beams = 25mm
d. Slabs = 25mm
5. All reinforcement to be twisted bars
B.S 4449.
6. All steel reinforcement must be
approved by the Structural Engineer
6Y12-02
X-01
X-02
X-03
X-04
250x 600 BEAM SB03
SCALE 1:25
3T10
T8-07
1
1 1
3T10
3T10
SECTION X01-X01
5 5 5 5 5 5 5 5
T8-07
5 5 5 5 5 5 5 5
3T10
3T10
SECTION X02-X02
6 6 6
T8-07
2
2 2 2
3T10
3T10
SECTION X03-X03
3 3 3 3 3 3 3 3
T8-07
3 3 3 3 3 3 3 3
3T10
3T10
SECTION X04-X04
X-03
5000
X-04
T8-07
3T10
SECTION X03-X03
1800
1 1
3T10
3T10
5 5 5 5 5 5 5 5
5 5 5 5 5 5 5 5
4 4 4 4
SECTION X02-X02
3T10
3T10
T8-07
SECTION X01-X01
200
X-02
3T10
3T10
3T10
3T10
X-01
3T10
3T10
200
4 4 4 4
3T10
3T10
3T10
6
200
3 3 3 3 3 3 3 3
3T10
3T10
200
T8-07
200
200
3 3 3 3 3 3 3 3
3T10
3T10
200
3T10
3T10
200
3T10
6 6 6
T8-07
2
2 2 2
3T10
SIGN DATE APPROVED
C4
3T10
C3
SECTION X04-X04
C2
C1
7Y12-22-200T1
1250
REVISION
REV
1250
C0
4Y10-21-200T2
CLIENT
5T10-18-200T2
AUSTIN NZIVO
8T16-03
8T16-05
6Y12-06
6Y12-04
4Y10-15-200T2
4Y10-20-200B2
7Y12-19-200B1
P.O BOX ******,
*******
7Y12-14-200T1
PROJECT
7Y12-16-200B1
PROPOSED KINDERGATEN
7Y12-13-200T1
14Y10-17-200B2
23T08-07-200
4Y10-09-200T2
8T08-07-200
6Y10-11-200B2
6Y12-01
X-01
6Y12-02
X-02
X-03
[email protected]
X-04
ARCHITECT
HK CONSULT LTD
16Y10-08-200B2
3T10
3T10
3T10
3T10
4
4 4 4 4
T8-07
1
1 1
3T10
3T10
3T10
3T10
5 5 5 5 5 5 5 5
T8-07
5 5 5 5 5 5 5 5
3T10
200
3 3 3 3 3 3 3 3
7Y12-07-200B1
200
T8-07
200
200
3T10
3T10
P.O BOX 12531-00400,
NAIROBI, KENYA
TEL:254 (020)5286184
Email:
[email protected]SCALE 1:25
3 3 3 3 3 3 3 3
BELHMANN CONSULTANTS
P.O BOX 36014-00200,
NAIROBI, KENYA
TEL:254717865382/704845027
7Y12-06-200T1
4Y10-05-200T2
250x 600 BEAM SB02
3T10
CONSULTING CIVIL STRUCTURAL ENGINEER
7Y12-10-200B1
7Y12-04-200T1
4Y10-03-200T2
3T10
LR N0. *************************
6Y10-12-200T2
3T10
4Y10-02-200B2
7Y12-01-200B1
3T10
6
6 6 6
T8-07
2
2 2 2
3T10
SLAB DETAILS
DRAWING TITLE
BEAM & STAIRCASE DETAILS
SCALE 1:20
Designed by
Checked by
SECTION X01-X01
SECTION X02-X02
SECTION X03-X03
SECTION X04-X04
Drawn by
D.O.O
N.B
Scale
Date
AS INDICATED ON THE DRAWING
Job No.
Status
Approved by
01-KTNGL
B.O.O
D.O.O
May 2016
ACAD File:
Drawing No.01/2016/KTNGL-04
STR01-KTNGL
CO REV