Example Calculations: Example Calculation For A Single Strong-Bolt 2 Anchor Using SD

Anchors

Uploaded by

mordidomi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
272 views2 pages

Example Calculations: Example Calculation For A Single Strong-Bolt 2 Anchor Using SD

Anchors

Uploaded by

mordidomi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry

Example Calculations Mechanical Anchors (ACI 318 App. D / ICC-ES AC193)


Example calculation for a single Strong-Bolt 2
anchor using SD:

1,600 lb.
560 lb.

Determine if a single 12" diameter carbon-steel Strong-Bolt 2 torquecontrolled expansion anchor with a minimum 3 78" embedment
(hef = 3 38 inches) installed 4" from the edge of a 12" deep spandrel
beam is adequate for a strength level tension load of 1,600 lb. for wind
and a reversible strength level shear load of 560 lb. for wind. The anchor
will be in the tension zone, away from other anchors in fc = 3,000 psi
normal-weight concrete.

338"

4"

Reference the appropriate tables in this catalog for Strong-Bolt 2 anchor


performance values as determined from testing in accordance with ACI
355.2 and ICC-ES AC193.
REFERENCE

Note: Calculations are performed in accordance with ACI 318-11.


1. Determine the factored tension
and shear design loads:

ACI 318, 9.2.1

Nua = 1.0W = 1.0 x 1,600 = 1,600 lb.


Vua = 1.0W = 1.0 x 560 = 560 lb.
2. Design considerations:

D.4.1.1

This is a combined tension and shear interaction


problem where values for both Nn and Vn need
to be determined. Nn is the lesser of the design
tension strength controlled by: steel (Nsa),
concrete breakout (Ncb), or pull-out (nNpn).
Vn is the lesser of the design shear strength
controlled by: steel (Vsa), concrete breakout
(Vcb), or pryout (Vcp).

REFERENCE

4. Concrete breakout capacity


under tension loading:

D.5.2

Ncb Nua

D.4.1.1

A
Ncb = Nc ed,N c,N cp,N Nb
A
Nco

Eq. (D-3);

where:

Nb = kc a fc hef1.5

Eq. (D-6)

substituting:
A

Ncb = Nc ed,N c,N cp,N kc afc hef1.5


A
Nco


where:
This catalog

D.4.1.1


kc = kcr = 17
(Anchor is installed in a tension zone, therefore,
cracking is assumed at service loads

Nsa = 12,100 lb.

This catalog

= 1.0 for normal-weight concrete

8.6.1

= 0.75

This catalog

cp,N = 1.0

D.5.2.7
Eq. (D-10)

Calculating for Nsa:

c
ed,N = 0.7 + 0.3 a,min when ca,min < 1.5 hef
1.5hef

Nsa = 0.75 x 1 x 12,100 = 9,075 lb. > 1,600 lb. O.K.

by observation, ca,min = 4 < 1.5hef

3. Steel capacity under tension Loading:

D.5.1

Nsa Nua

n = 1 (single anchor)

Appendix

CALCULATIONS AND DISCUSSION

(4)
ed,N = 0.7 + 0.3
= 0.94
1.5(3.375)

Would you like help with these calculations?


Visit www.strongtie.com to download the
SimpsonStrongTie Anchor Designer software.


c,N = 1.0 assuming cracking
at service loads (ft > fr)

D.5.2.6


= 0.65 for Condition B
(no supplementary reinforcement provided)

This catalog

ANco = 9hef2
= 9(3.375)2
= 102.52 in.2

Eq. (D-5)

ANc = (ca1 + 1.5hef)(2 x 1.5hef)


= (4 + 1.5(3.375))(2 x 1.5(3.375))
= 91.76 in.2

Fig. RD.5.2.1(a)

A
Nc = 91.76 = 0.90
A
Nco 102.52
Calculating for Ncb:
Ncb = 0.65 x 0.90 x 0.94 x 1.0 x 1.0 x 17 x 1.0 x


3,000 x (3.375)1.5 = 3,175 lb. > 1,600 lb. O.K.

Continued on next page
326

C-A-2016 2015 SIMPSON STRONG-TIE COMPANY INC.

CALCULATIONS AND DISCUSSION

Note: Rebar not


shown for clarity

Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry

Example Calculations Mechanical Anchors (ACI 318 App. D / ICC-ES AC193)


CALCULATIONS AND DISCUSSION

REFERENCE

CALCULATIONS AND DISCUSSION

REFERENCE

5. Pullout capacity under tension loading:

D.5.3

9. Concrete pryout strength:

D.6.3

Pullout capacity, Np,cr, is established by reference tests in cracked concrete


by the reliability test of ACI 355.2. Data from the anchor prequalification
testing must be used. Reference Strong-Bolt 2 anchor characteristic
tension design values table for the 5 percent fractile value, Np,cr.

nVcp Vua

D.4.1.1

Vcp = kcp Ncb

Eq. (D-40)

Npn Nua

D.4.1.1

n=1

This catalog

kcp = 2.0 and = 0.70

This catalog

This catalog

kcp Ncb = 2.0 x 3,175 = 9,769 lb.


0.65

D.6.3.1

D.4.1.1

nVcp = 0.70 x 1 x 9,769 = 6,838 lb. > 560 lb. O.K.

0.5

= 4,091 lb.

Npn = 0.65 x 4,091 = 2,659 lb. > 1,600 lb. O.K.


6. Check all failure modes under tension loading:
Summary:
Steel capacity
= 9,075 lb.
Concrete breakout capacity = 3,175 lb.
Pullout capacity
= 2,659 lb. Controls
Nn = 2,659 lb. as pullout capacity controls

10. Check all failure modes under shear Loading:


Summary:
Steel capacity

= 4,703 lb.

7. Steel capacity under shear loading:

D.6.1

Concrete breakout capacity = 2,224 lb. Controls

Vsa Vua

D.4.1.1

Pryout capacity

Vsa = 7,235 lb.

This catalog

= 0.65

This catalog

Vn = 2,224 lb. as concrete breakout capacity controls

Calculating for Vsa:


Vsa = 0.65 x 7,235 = 4,703 lb. > 560 lb. O.K.

= 6,838 lb.

11. Check interaction of tension and shear forces:

D.7
D.7.1

8. Concrete breakout capacity under shear loading:

D.6.2

If 0.2 Vn Vua, then the full tension


design strength is permitted.

Vcb Vua

D.4.1.1

By observation, this is not the case.

Eq. (D-30)

If 0.2 Nn Nua, then the full shear


design strength is permitted

A
Vcb = Vc ed,V c,V h,v Vb
AVco

where:
0.2

da a fc ca11.5
Vb = 7 e
da

D.7.2

By observation, this is not the case.

( )

C-A-2016 2015 SIMPSON STRONG-TIE COMPANY INC.

D.4.1.1

Eq. (D-33)

substituting:
A
Vcb = Vc ed,V c,V h,v 7 e
AVco
d

( )

N
V
ua + ua 1.2
N
V
n
n

da a fc ca11.5

0.2

Eq. (D-42)

1,600 + 560 = 0.60 + 0.25 = 0.85 < 1.2 O.K.


2,224
2,659

where:

= 0.70 for Condition B
(no supplementary reinforcement provided)

D4.4(c)(i)

AVco = 4.5ca12

= 4.5(4)2
AVco = 72 in.2

Eq. (D-32)

AVc = 2(1.5ca1)(1.5ca1)

= 2(1.5(4))(1.5(4))
AVc = 72 in.2

Fig. RD.6.2.1(a)

A
Vc = 72 = 1
A
Vco 72

Therefore:

12. Summary

A single 12" diameter carbon-steel Strong-Bolt 2 anchor
at a 3 78" embedment depth is adequate to resist the
applied strength level tension and shear wind loads of 1,600 lb.
and 560 lb., respectively.

Appendix

Np,cr = 3,735 x

= 0.65

3,000
2,500

where:

D.6.2.1

ha = 12 in.
h,v = 1.0 since ha > 1.5 Ca1

D.6.2.8

ed,V = 1.0 since ca2 > 1.5ca1

Eq. (D-37)


c,V = 1.0 assuming cracking
at service loads (ft > fr)

D.6.2.7

da = 0.5 in.

= 3.375 in.

D.6.2.2

a = 1.0 for normal-weight concrete


ca1 = 4 in.

8.6.1

0.2

Vcb = 0.70 x 1 x 1.0 x 1.0 x1.0 x 7 x 3.375


x 0.5 x 1.0
0.5


x 3,000 x (4)1.5 = 2,224 lb. > 560 lb. O.K.

327