Flatpack2

Power Systems
Overview:
The Eltek Valere Flatpack2 line consists of versatile,
scalable, and highly-configurable systems tailored to
customer requirements.
Use of established
componentsincluding the efficient and reliable
Flatpack2 rectifier, the robust Smartpack controller,
and flexible distribution unitsmakes for optimal
system design and cost-effective deployment.

Flatpack2 +24V 600A

Flatpack2 Power System

Flatpack2 Rectifiers

The Flatpack2 (FP2) power core features an impressive


array of distribution configurations and options. Its
compact design and efficient use of space complement
sites with limited floor and rack space, opening room for
better airflow and additional equipment. Flatpack2
chassis are designed to mount in standard 19 or 23
telecommunications racks. Standard, fully-populated
configurations accommodate four to sixteen Flatpack2
rectifiers, yielding total power output ranges of 8kW to
32kW.

Distribution Features
o Breaker alarming
o Low-voltage disconnect (LVD) contactor options
o Horizontal load landings, vertical bulk battery
landings
o Three distribution options for different power levels:
o Small 1U, 175A shelf with controller slot, LVD
option, up to six protected output buses, and up
to two unprotected battery buses
o Three-bus, 600A, 19 wide, 4U high panel with
20 positions for plug-in circuit breakers or fuse
holders, up to two LVD contactors, and rear bulk
battery terminals
o Three-bus, 600A, 23 wide, 4U or 6U high panel
with 24 positions for plug-in circuit breakers or
fuse holders, emergency power-off (EPO)
switch, up to two LVD contactors, and rear bulk
battery terminals; an additional 23 distribution
panel option doubles the number of cable
landings.

CORE Telecom
www.eltekvalere.com

Systems

o New! Flatpack2 HE with 96% typical efficiency


o Input voltage range: 85 290 VAC
o 2000W DC output (constant power)
o 1U in height; 4.25 in width
o Hot-swap/hot-plug functionality
o Automatic active load sharing

Smartpack Controllers
o Provide comprehensive system monitoring and
control in a single unit
o Local and remote interfaces
o PowerSuite software for computer interface
o Advanced battery-monitoring and thermal
compensation
o Various models providing up to six configurable
alarm inputs and output relays
o Web model for TCP/IP or SNMP communication
o Slave controller option for larger systems

Power Shelves
o Accommodate up to four rectifiers each
o 1U height (1.75); 19 width
o Individual and dual AC feed options
o Mounting brackets for 19 and 23 racks

(888) 375-8826

Copyright 2008, Eltek Valere


www.coretelecom.net
2048206 R2

Document
2048206 R2

Flatpack2 Power Systems


Configurations
Flatpack2 Systems
Standard Systems*

-48V/150A

-48V/300A

-48V/600A

+24V/600A

+24V/1200A

Output Power

8kW

14kW

32kW

16kW

32kW

Maximum Output
Current (DC)

168A

294A

672A

672A

1344A

Image

2RU (3.5)

6RU (10.5)

9RU (15.75)

7RU (12.25)

10RU (17.5)

Controller Slots

Rectifier Slots

16

16

Distribution
Dimensions**

Height: 1RU (1.75)


Width: 19 (rack)
Depth: 18.75

Total Height**

Height: 4RU (7.0)


Width: 19 (rack)
Depth: 18.75

Height: 4RU (7.0)


Width: 23 (rack)
Depth: 21.75

Height: 4RU (7.0)


Width: 23 (rack)
Depth: 21.75

Height: 6RU (10.5)


Width: 23 (rack)
Depth: 21.75

Configurable Load
Buses

Up to 6 (or 3 pairs)

Protected Load
Landings

Up to 6 (or 3 pairs)

Up to 20

Up to 24

Up to 24

Up to 24

Load Landing Lug Sizes

Two-hole 1/4-20 on
5/8 centers, up to
#1 AWG

Two-hole 1/4-20 on
5/8 centers, up to
#1 AWG

Two-hole 1/4-20 on
5/8 centers, up to
#1 AWG

Two-hole 1/4-20 on
5/8 centers, up to
#1 AWG

Two-hole 1/4-20 on
5/8 centers, up to
#1 AWG

Bulk Battery Landings

2 (optional)

Two-hole 1/4-20 on
5/8 centers

Two-hole 3/8-16 on
1 centers

Two-hole 3/8-16 on
1 centers

Two-hole 3/8-16 on
1 centers

Two-hole 3/8-16 on
1 centers

Battery Landing Lug


Sizes

Up to 1

Up to 2

Up to 2

Up to 2

Up to 2

EPO Circuit and Service


Bypass Switch

No

No

Yes

Yes

Yes

Additional Distribution
Panel Option

No

No

Yes

Yes

Yes

LVD Contactor

*Please consult with a sales representative for other available configurations


**Dimensions are approximate

Applicable Standards#
NEBS
IEC 60950-1
UL 60950-1

Level 3 (GR-63-CORE, GR-1089-CORE)


Electrical safety

EN 55022
(CISPER 22)

Radiated disturbance at enclosure port


Conducted emission at DC output ports
Conducted emission at AC mains ports

EN 61000-3-2
EN 61000-3-3 20

Harmonic current emissions

EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-9

Electrostatic discharge (ESD) immunity test


Electromagnetic field immunity test
Electrical fast transient/burst immunity test
Surge immunity test
Conducted radio-frequency (RF) immunity test

EN 61000-4-11

Voltage dips, short interruptions and voltage variations

Power frequency magnetic field/pulse magnetic field

Agency approvals for the 48V/150A configuration are pending

www.eltekvalere.com
Headquarters:
Eltek Valere
1303 E. Arapaho Rd. Richardson, TX. 75081, USA
Phone: +1 (469) 330-9100
Fax: +1 (469) 330-2955

CORE Telecom Systems

PAGE
OF 5
(888)2 375-8826

www.coretelecom.net

Document
2048206 R2

Flatpack2 Power Systems


Distributions

Flatpack2 150A

The -48V/150A system offers five standard distribution configurations which are defined by the number of
breaker or fuse positions available. Distribution consists of up to three sets of two parallel buses, with each bus
having its own front-access, plug-in breaker (or plug-in fuse holder) position and rear-access cable landing. This
parallel configuration permits each set of two buses to be linked together by a two-pole plug-in breaker.
Additionally, one low-voltage disconnect (LVD) contactor may be installed.
FP2 -48V/150A
Configurations*

2B 2L

2B 2L GMT

2B 4L

4L GMT

6L

100A battery breaker positions

60A load breaker positions

12-position, 65A GMT fuse block

No

Yes

No

Yes

No

2 unprotected bulk battery landings

No

No

No

Yes

Yes

*Please consult with a sales representative for other available configurations

Flatpack2 300A, 600A, and 1200A


The larger Flatpack2 systems make use of a unique front-access distribution section that features three discrete
parallel buses. Each bus has positions for breaker holders that screw into one of the three buses. This
arrangement facilitates a variety of convenient uses for each bus, such as protected battery connections, loadshedding, and converter output. Kits are available for double-pole and triple-pole breakers. Bulk battery cable
landings are available in the rear of these distributions. There are also options for up to two LVD contactors.
Return
Landings
Breaker
Holder

Cable
Landing

BUS 1
BUS 2
BUS 3

Distributions*
Distribution Dimensions

300A

600A

Height: 4RU (7.0)


Width: 19 (rack)
Depth: 24

1200A

Height: 4RU (7.0)


Width: 23 (rack)
Depth: 24

Height: 6RU (10.5)


Width: 23 (rack)
Depth: 24

Controller Slot(s)

One (1) in power shelf

Two (2) in separate shelf

Two (2) integrated in distribution

Alarm Card(s)

Integrated

Separate shelf

Integrated

Configurable Load Buses

Protected Load Landings

Up to 20

Up to 24

Up to 24

Load Landing Lug Sizes

Two-hole 1/4-20 on 5/8 centers,


up to #1 AWG
4

Bulk Battery Landings


Battery Landing Lug Sizes

Two-hole 1/4-20 on 5/8 centers,


up to #1 AWG
8

Two-hole 3/8-16 on 1 centers, up


to 250 MCM

Two-hole 1/4-20 on 5/8 centers,


up to #1 AWG
8

Two-hole 3/8-16 on 1 centers, up


to 777 MCM

Two-hole 3/8-16 on 1 centers, up


to 777 MCM

Up to 2

Up to 2

Up to 2

EPO Circuit and Service


Bypass Switch

No

Yes

Yes

Optional Auxiliary
Distribution Panel

No

Yes

Yes

LVD Contactors

*Please consult with a sales representative for other available configurations

www.eltekvalere.com
Headquarters:
Eltek Valere
1303 E. Arapaho Rd. Richardson, TX. 75081, USA
Phone: +1 (469) 330-9100
Fax: +1 (469) 330-2955

CORE Telecom Systems

PAGE
OF 5
(888)3 375-8826

www.coretelecom.net

Document
2048206 R2

Flatpack2 Power Systems


Power Modules

Flatpack2 Rectifiers

Flatpack2 rectifiers are available in two voltages: 48V and 24V. They are hot-swap, switched-mode power supply
units that deliver a constant 2000W of DC power.
Flatpack2 Rectifiers*

48V 2000W

HE (48V 2000W)

24V 2000W

Module Image

AC Input Voltage

Range: 85-300 VAC


Nominal: 185-275 VAC

Range: 85-300 VAC


Nominal: 185-275 VAC

Range: 85-290 VAC


Nominal: 176-275 VAC

Maximum AC Current

11.6 Arms

12.5 Arms

13.4 Arms

DC Output Voltage

43.5-57.6 VDC

43.5-57.6 VDC

21.0-29.0 VDC

Maximum DC Current

41.7A

41.7A

84.0A

Typical Efficiency

>96%

92%

89%

Operating Temperature

-40C to +75C (-40F to +167F)

-40C to +75C (-40F to +167F)

-40C to +75C (-40F to +167F)

Storage Temperature

-40C to +85C (-40F to +185F)

-40C to +85C (-40F to +185F)

-40C to +85C (-40F to +185F)

Cooling

One fan, front-to-back airflow

Two fans, front-to-back airflow

Two fans, front-to-back airflow

Dimensions

Height: 41.5 mm (1.63)


Width: 109 mm (4.29)
Depth: 327 mm (12.87)

Height: 41.5 mm (1.63)


Width: 109 mm (4.29)
Depth: 327 mm (12.87)

Height: 41.5 mm (1.63)


Width: 109 mm (4.29)
Depth: 327 mm (12.87)

Weight

1.95 kg (4.30 lbs)

1.9 kg (4.19 lbs)

1.9 kg (4.19 lbs)

*Please consult with a sales representative for other available models

Flatpack Converters
Flatpack DC-DC Converters can be ordered for Flatpack2 systems. Converter shelves are delivered in sets of two
or four shelves (four or eight converters, respectively). Each shelf accommodates up to two converter modules.
In 300A, 600A, and 1200A distributions, converter output can be routed to one of the three parallel load buses.
Flatpack DC-DC
Converters*

48V to 24V

24V to 48V

Module Image

Input Voltage

40-60 VDC

19.8-32.0 VDC

Input Current

32A at 40 VDC

73A at 19.8 VDC

Output Voltage

24-28 VDC

55 VDC

Output Current

40A at 24 VDC

23A

Output Power

1100W at 27.5 VDC

1250W

Typical Efficiency

90%

90%

Operating Temperature

-40C to +75C (-40F to +167F)


Power limiting may occur above +65C (+149F)

-40C to +75C (-40F to +167F)


Power limiting may occur above +65C (+149F)

Storage Temperature

-40C to +85C (-40F to +185F)

-40C to +85C (-40F to +185F)

Dimensions

Height: 43 mm (1.69)
Width: 218 mm (8.58)
Depth: 240 mm (9.45)

Height: 43 mm (1.69)
Width: 218 mm (8.58)
Depth: 240 mm (9.45)

Weight

<3 kg (<6.6 lbs)

<3 kg (<6.6 lbs)

*Please consult with a sales representative for other available models

www.eltekvalere.com
Headquarters:
Eltek Valere
1303 E. Arapaho Rd. Richardson, TX. 75081, USA
Phone: +1 (469) 330-9100
Fax: +1 (469) 330-2955

CORE Telecom Systems

PAGE
OF 5
(888)4 375-8826

www.coretelecom.net

Document
2048206 R2

Flatpack2 Power Systems


Controller Modules

Smartpack Controller

Smartpack is a robust, comprehensive control and monitoring device used for Eltek Valeres Flatpack2 systems.
The controller communicates with each Flatpack2 rectifier through a CAN bus and provides real-time monitoring
and control information. The Smartpack controller is accompanied by the PowerSuite software program for PC
interface. Alarm inputs and output relays can be increased by using a master/slave configuration in systems that
can accommodate two controllers.

Smartpack Modules*

Extended

Web/SNMP

Slave

Rear View

Rear View

Front View

Module Image

24 60 VDC

24 60 VDC

24 60 VDC

Configurable Alarm Inputs

Form C Output Relays

Computer Interface

USB

USB
Ethernet

USB

Front Display

Input Voltage

Yes

Yes

No

Battery Symmetry Inputs

Temperature Sense Inputs

Battery Current/Fuse Fail


Monitoring

Yes

Yes

Yes

LVD Control

Up to 2 contactors

Up to 2 contactors

Up to 2 contactors

Dimensions

Height: 44 mm (1.73)
Width: 109 mm (4.29)
Depth: 140 mm (5.51)

Height: 44 mm (1.73)
Width: 109 mm (4.29)
Depth: 140 mm (5.51)

Height: 44 mm (1.73)
Width: 109 mm (4.29)
Depth: 140 mm (5.51)