Series-Parallel Connection of Low-Voltage
Sources for Integration of Galvanically
Isolated Energy Storage Systems
Introduction:
The increasing penetration of distributed generation and Energy
Storage Systems (ESS) into the distribution grid is boosting the growth
of Microgrids and Smartgrids. A Front-End Converter (FEC) connects a
given load (which can be generalized as a Microgrid) to the three-phase
distribution line. The main ESS, formed by the battery and a Main
Storage Converter, is intended to support the DC link voltage in case of
load variations or line fluctuations. In this work, the Full- Bridge
Current-Source (FBCS) converter has been selected as a suitable
topology. This main ESS and its associated converter might have
limitations in the power rating and bandwidth (due reliability, expected
operating life or efficiency constraints). These limitations might affect
the transient behavior of the storage system. Upon a power demand from
the load, the power will initially be given by the DC link capacitor,
which in turn will be discharged. It will take some time, depending on
the design, for the ESS to be able to provide the required power to the
DC link. This voltage drift might cause problems in the performance of
the full system.
Copyright 2016LeMenizInfotech. All rights reserved
LeMenizInfotech
36, 100 Feet Road, Natesan Nagar, Near Indira Gandhi Statue,
Pondicherry-605 005.
Call: 0413-4205444, +91 9566355386, 99625 88976.
Web :www.lemenizinfotech.com/ www.ieeemaster.com
Mail : [email protected]
The Master of IEEE Projects
Proposed system:
This work explores the Series-Parallel Connection of a Low
Voltage Supercapacitor Module to obtain a Hybrid Energy Storage
System for grid support applications. The Hybrid System is formed by
the Supercapacitor Module itself, intended to ensure fast performance
upon peak power requirements, together with a battery that provides the
energy requirements. In the full system, the front end converter and the
load interfacing converter share a common DC link. The battery is
connected to the DC link by means of a Full-Bridge Current-Source
bidirectional DC-DC converter.
Copyright 2016LeMenizInfotech. All rights reserved
LeMenizInfotech
36, 100 Feet Road, Natesan Nagar, Near Indira Gandhi Statue,
Pondicherry-605 005.
Call: 0413-4205444, +91 9566355386, 99625 88976.
Web :www.lemenizinfotech.com/ www.ieeemaster.com
Mail : [email protected]
The Master of IEEE Projects
Block diagram:
Full Bridge
Current Source
Inverter
Battery
Supply
12V DC
HF
Transformer
Full Bridge
AC-DC
Converter
Auxiliary
Storage Circuit
Driver Circuit
Output
Capacitor
Load
Buffer Circuit
5V DC
Micro Controller
Circuit
Copyright 2016LeMenizInfotech. All rights reserved