0% found this document useful (0 votes)
278 views2 pages

CIP Programs PDF

The document describes 14 cleaning programs supported by the Tetra Alcip 100 machine. Each program consists of a series of cleaning cycles like pre-rinsing, use of chemicals like lye and acid, disinfection, and rinsing. The programs are designed to clean objects like pipes, tanks, and filling machines using different combinations and sequences of cleaning cycles.

Uploaded by

Nguyen Hai
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
278 views2 pages

CIP Programs PDF

The document describes 14 cleaning programs supported by the Tetra Alcip 100 machine. Each program consists of a series of cleaning cycles like pre-rinsing, use of chemicals like lye and acid, disinfection, and rinsing. The programs are designed to clean objects like pipes, tanks, and filling machines using different combinations and sequences of cleaning cycles.

Uploaded by

Nguyen Hai
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Cleaning Programs

2 Process Description

Cleaning Programs
A total of 14 different cleaning programs are supported by the
Tetra Alcip 100. Each program is designed to handle cleaning of objects as
sanitary pipes, tanks, heat exchangers and filling machines.
Program 1
LYE

Program 2
ACID

Program 3
LYE & ACID

Initial
Pre-rinse
Lye
Intermediate rinse 1
Final rinse
End

Initial
Pre-rinse
Acid
Intermediate rinse 2
Final rinse
End

Initial
Pre-rinse
Lye
Intermediate rinse 1
Acid
Intermediate rinse 2
Final rinse
End

Program 4
ACID & LYE

Program 5
LYE & ACID & LYE

Program 6
LYE & HOT WATER

Initial
Pre-rinse
Acid
Intermediate rinse 2
Lye
Intermediate rinse 1
Final rinse
End

Initial
Pre-rinse
Lye
Intermediate rinse 1
Acid
Intermediate rinse 2
Lye
Intermediate rinse 1
Final rinse
End

Initial
Pre-rinse
Lye
Intermediate rinse 1
Hot water
Final rinse (skipped if final
rinse temperature setpoint
= 0)
End

Program 7
LYE& ACID &
HOT WATER

Program 8
ACID & LYE &
HOT WATER

Program 9
LYE & DISINFECTION

Initial
Pre-rinse
Lye
Intermediate rinse 1
Acid
Intermediate rinse 2
Hot water
Final rinse (skipped if final
rinse temperature setpoint
= 0)
End

Initial
Pre-rinse
Acid
Intermediate rinse 2
Lye
Intermediate rinse 1
Hot water
Final rinse (skipped if final
rinse temperature setpoint
= 0)
End

Initial
Pre-rinse
Lye
Intermediate rinse 1
Disinfection
End

(Cont'd)

Doc. No. OM-1225510-0101

2 - 15 (24)

Cleaning Programs

2 Process Description

(Cont'd)

2 - 16 (24)

Program 10
LYE & ACID &
DISINFECTION

Program 11
DISINFECTION

Program 12
FINAL RINSE

Initial
Pre-rinse
Lye
Intermediate rinse 1
Acid
Intermediate rinse 2
Disinfection
End

Initial
Disinfection
End

Initial
Final rinse
End

Program 13
DISINFECTION & FINAL
RINSE

Program 14
HOT WATER

Initial
Disinfection
Final rinse
End

Initial
Hot water
Final rinse (skipped if final
rinse temperature setpoint
= 0)
End

Doc. No. OM-1225510-0101

You might also like