Series IRK.136, .142, .162: NEW INT-A-pak Power Modules Thyristor/Diode and Thyristor/Thyristor
Series IRK.136, .142, .162: NEW INT-A-pak Power Modules Thyristor/Diode and Thyristor/Thyristor
Series IRK.136, .142, .162: NEW INT-A-pak Power Modules Thyristor/Diode and Thyristor/Thyristor
C 03/02
SERIES
IRK.136, .142, .162
THYRISTOR/DIODE and
THYRISTOR/THYRISTOR
Features
135 A
140 A
160 A
High Voltage
Electrically Isolated by DBC Ceramic ( Al 2 O 3 )
3500 V RMS Isolating Voltage
Industrial Standard Package
High Surge Capability
Glass Passivated Chips
Modules uses High Voltage Power thyristor/diodes
in three Basic Configurations
Simple Mounting
UL E78996 approved
Applications
DC Motor Control and Drives
Battery Charges
Welders
Power Converters
Lighting Control
Heat and Temperature Control
140
160
85
85
85
300
310
355
ITSM @ 50Hz
3200
4500
4870
@ 60Hz
3360
4712
5100
I2t @ 50Hz
51.5
102
119
KA2s
@ 60Hz
I2t
47
92.5
108
KA2s
515.5
1013
1190
KA2s
VRRM
400 to 1600
TJ range
- 40 to 125
www.irf.com
Electrical Specifications
Voltage Ratings
Type number
IRK.136
04
400
500
IRK.142
08
800
900
IRK.162
12
1200
1300
14
1400
1500
16
1600
1700
IRRM / IDRM
@ 125C
mA
50
Forward Conduction
Parameter
IT(AV) Max. average on-state current
IRK.136
IRK.142
IRK.162
Units Conditions
135
140
160
A
C
@ Case temperature
85
85
85
300
310
355
as AC switch
3200
4500
4870
t = 10ms
on-state, non-repetitive
3360
4712
5100
t = 8.3ms reapplied
surge current
2700
3785
4100
t = 10ms
2800
3963
4300
t = 8.3ms reapplied
51.5
102
119
47
92.5
108
t = 8.3ms reapplied
36.5
71.6
84
t = 10ms
ITSM
I2t
I2t
33.3
65.4
76.7
515.5
1013
1190
0.86
0.83
0.8
1.05
0.98
2.02
1.78
1.67
1.65
1.43
1.38
1.57
1.55
1.54
KA2s
t = 10ms
No voltage
100% VRRM
No voltage
100% VRRM
t = 8.3ms reapplied
KA2s t = 0.1 to 10ms, no voltage reapplied
V
voltage
VT(TO)2 High level value of threshold
voltage
rt1
slope resistance
rt2
slope resistance
V
VTM
IH
200
mA
IL
400
mA
Switching
tgd
tgr
tq
50 - 200
TJ = 25oC
TJ = 25 C
Vd=0,67% VDRM
www.irf.com
IDRM
VINS
50
mA
TJ = 125oC
3500
1000
V/s
IRK.142
IRK.162
Triggering
Parameter
PGM
IRK.136
Units Conditions
12
tp 5ms, TJ = TJ max.
f=50Hz, TJ = TJ max.
tp 5ms, TJ = TJ max.
IGM
-VGT
10
gate voltage
VGT
TJ = - 40C
TJ = 25C
load; Ra = 1
voltage to trigger
2.5
1.7
TJ = TJ max.
270
TJ = - 40C
current to trigger
150
mA
TJ = 25C
load; Ra = 1
VGD
80
0.3
IGD
10
mA
300
A/s
IGT
di/dt
TJ = TJ max.
@ TJ = TJ max., rated VDRM applied
IRK.136
IRK.142
IRK.162
Units Conditions
TJ
-40 to 125
Tstg
temperature range
Max. storage temperature
-40 to 150
RthJC
range
Max. thermal resistance,
junction to case
0.18
RthCS
Mounting
IAP to heatsink
torque 10% busbar to IAP
Approximate weight
wt
Case Style
0.18
0.16
K/W
0.05
K/W
4 to 6
4 to 6
200 (7.1)
Nm
g(oz)
New Int-A-Pak
Devices
120o
90o
60o
180o
120o
90o
60o
30o
IRK.136
0.007
0.01
0.013
0.0155
0.017
0.009
0.012
0.014
0.015
0.017
IRK.142
0.0019
0.0019
0.0020
0.0020
0.0021
0.0018
0.0022
0.0023
0.0023
0.0020
IRK.162
0.0030
0.0031
0.0032
0.0033
0.0034
0.0029
0.0036
0.0039
0.0041
0.0040
www.irf.com
Units
K/W
IRK
162
16
4
Module Type
Circuit Configuration
Outline Table
IRKT
IRKH
IRKL
5 7
4 6
5
4
7
6
www.irf.com
13 0
IRK.136.. Series
R thJC (D C ) = 0.18 K/W
12 0
11 0
C o nd uctio n Angle
10 0
90
30
60
90
80
120
180
70
0
20
40
60
80
10 0
12 0
14 0
IRK .1 3 6 .. Se ries
R thJC (D C ) = 0 .1 8 K/W
12 0
11 0
C o n d u c tio n P e rio d
10 0
30
60
90
90
120
80
180
0
50
RM S Lim it
100
C o nd uctio n Angle
50
0
0
30
60
90
12 0
15 0
180
120
90
60
30
150
DC
180
120
90
60
30
300
250
200
100
C o n d uc tio n P eriod
50
0
0
50
24 0 0
22 0 0
20 0 0
18 0 0
16 0 0
IRK.136.. Series
Per Junction
12 0 0
1
10
10 0
www.irf.com
1 00
1 50
2 00
2 50
In itial TJ = 125 C
@ 60 Hz 0.00 83 s
@ 50 Hz 0.01 00 s
14 0 0
RM S Lim it
26 0 0
25 0
150
28 0 0
2 00
350
30 0 0
15 0
300
200
100
250
DC
70
35 0 0
30 0 0
RRM
25 0 0
20 0 0
15 0 0
IRK.1 36.. Se ries
Pe r Ju nction
10 0 0
0 .0 1
0.1
450
S
R th
W
K/
. 01
=0
/W
4K
e lt
-D
aR
50
K /W
150
IRK.136.. Se rie s
Pe r M odule
TJ = 12 5 C
K /W
0 .6
100
0 .0
0 .4
200
K/
250
K/
K/
C onductio n Angle
25
08
300
0.
16
350
K/
0.
180
120
90
60
30
12
400
0.
0.
1 K/
W
0
0
50
100
150
200
250
300
0
25
50
75
1 00
125
A
hS
R t
90 0
0.
04
60 0
0 .2
K/
K/
50
75
a
e lt
-D
50 0
08
180
(Sine )
180
(Re ct)
12
K/
0.
. 01
=0
0.
70 0
80 0
K/
K /W
M axim um To ta l P o we r Lo ss (W )
1 0 00
40 0
0 .3 5
30 0
K /W
2 x IRK.136.. Series 0 .
6 K /W
Single P hase Brid ge
C onnected
T J = 125 C
20 0
10 0
0
0
55
11 0
165
220
2 07 5
25
100
125
R
th
12 0 0
SA
0.
el
ta
R
6K
/
-D
0 .1
60 0
K/
K/
08
0.1
K/
0.
120
(Rec t)
90 0
04
M a xim u m To ta l Po w e r Lo ss (W )
15 0 0
0 . 25
K /W
3 x IR K.1 3 6.. Serie s
Th ree Ph a se B rid g e 0 .4 K / W
C o n n ec te d
1 K /W
T J = 12 5 C
30 0
0
0
10 0
20 0
3 00
To ta l O u tp u t C u rre nt (A )
4 000
25
50
75
1 00
1 25
www.irf.com
IRK.142.. Series
R thJC (D C ) = 0.18 K/W
120
110
C o nd uctio n Angle
100
30
90
60
90
80
120
180
70
0
30
60
90
1 20
1 50
130
130
IR K.1 4 2 .. Se rie s
R thJC (D C ) = 0 .1 8 K /W
120
110
C o n d uc tio n P e rio d
100
30
60
90
90
120
80
180
DC
70
0
50
200
25 0
180
120
90
60
30
20 0
15 0
RMS Lim it
10 0
C o nd uc tio n Angle
50
0
0
30
60
90
1 20
1 50
35 0
DC
180
120
90
60
30
30 0
25 0
20 0
15 0 R M S L im it
C o nd u c tio n Pe rio d
10 0
IRK .1 4 2 .. Se rie s
P er Ju n c tio n
TJ = 12 5 C
50
0
0
50
In itial T J= 125 C
@ 60 Hz 0.00 83 s
@ 50 Hz 0.01 00 s
40 0 0
35 0 0
30 0 0
25 0 0
IRK.142.. Series
Per Junction
15 0 0
1
10
10 0
www.irf.com
1 50
2 00
2 50
45 0 0
1 00
15 0
25 0
20 0 0
100
M axim um A ve ra ge O n -sta te Po w er Lo ss (W )
5 00 0
4 50 0
4 00 0
3 50 0
3 00 0
2 50 0
2 00 0
1 50 0
0 .0 1
0 .1
400
R
W
/
4K
0.0
W
K/
08
0.
W
K/
12 W
K/
16
0.
0.
th
SA
0.
K/
0 .6
aR
200
K/
e lt
-D
0 .4
25
K /W
180
120
90
60
30
300
.0 1
=0
K/W
C o nductio n A n g le
1K
/W
IRK.142.. Se rie s
Per M odule
T J = 125 C
100
0
0
50
100
150
200
250
300
25
50
75
10 0
12 5
hS
R t
0.
04
/W
1K
2 00
100
To ta l O u tp ut C u rre nt (A )
lta
0 .2
e
-D
.0
=0
2K
/W
0.1
6K
/W
2 x IR K .1 4 2.. Se ries
Sin g le P h a se Brid g e
C o n n ec te d
T J = 12 5 C
20 0
40 0
K/
0 .1
180
(Sine )
180
(Re ct)
60 0
08
0.
80 0
K/
M a xim um Tota l P o w er Lo ss (W )
1 00 0
5K
/W
0 .6 K
/W
0
3 00
25
50
75
10 0
12 5
S
R th
0.
06
K/
e
-D
0.0
8 00
/
2K
0.
120
(Rec t)
0.0
12 0 0
K/
04
8K
/W
l ta
R
16 0 0
0.1
K/
W
3 x IRK.142.. Series
Three P hase Brid ge 0 .1 6 K /W
C o nnected
0.2 K/W
TJ = 125 C
4 00
0
0
5 0 10 0 1 5 0 20 0 25 0 30 0 35 0 4 0 0 450 0
Total O utp ut C urre nt (A)
25
50
75
10 0
12 5
www.irf.com
IRK.162.. Series
R thJ C (D C ) = 0.16 K/W
120
110
C o nd uc tio n Angle
100
90
30
60
90
80
120
180
70
0
30
60
90
1 20
150
180
130
1 30
1 20
1 10
1 00
C on d uctio n P e rio d
30
90
60
80
90
120
70
180
0
50
100
15 0
20 0
2 50
300
4 00
IRK .162.. Se ries
3 50 Per Junction
TJ = 125 C
3 00
180
120
2 50
90
60
2 00
30
RM S Lim it
1 50
1 00
50
C o nd uc tio n Angle
0
0
20
40
60
8 0 10 0 1 20 1 40 1 6 0 1 8 0
40 0
DC
180
120
90
60
30
35 0
30 0
25 0
20 0
RM S Lim it
15 0
C o n du c tio n Pe rio d
10 0
IRK.162.. Se ries
Per Junctio n
T = 125 C
50
0
0
30
4 00 0
In itial T J = 125 C
@ 60 Hz 0.00 83 s
@ 50 Hz 0.01 00 s
3 50 0
3 00 0
2 50 0
2 00 0
IRK.162.. Series
Per Jun ction
1 50 0
1
10
10 0
www.irf.com
9 0 1 2 0 15 0 1 80 2 10 2 4 0 2 7 0
4 50 0
60
DC
60
50 0 0
45 0 0
40 0 0
35 0 0
30 0 0
25 0 0
20 0 0
15 0 0
0.0 1
0 .1
600
S
R th
A
0. 0
K/
2
K/
W
ta
el
-D
6K
/W
0.2
C onductio n An gle
K /W
IRK.162.. Se rie s
Pe r M odule
T J = 125 C
100
04
K/
0 .1
200
K/
0.1
300
08
K/
400
0.
06
180
120
90
60
30
500
0.
0.
0
0
100
200
400
0
300
25
50
75
100
125
0.
8 00
0.2
0 .4
3 00
K/
ta
el
0.3
-D
4 00
5 00
K/
K/
180
(Sine )
180
(Re ct)
04
6 00
12
K/
0.
0.
7 00
08
A
hS
Rt
9 00
K /W
K /W
2 x IRK.162.. Series 0 .6
K /W
Single Phase Brid ge
1 K /W
C onnected
T J = 125 C
2 00
1 00
0
0
50
100
15 0
20 0
25 0
0
3 00
25
50
75
10 0
12 5
04
K/
1 2 50
S
R th
0.
K/
K/
e lt
-D
2 K
/W
7 50
0 .1
120
(Rect)
08
0. 0
0.
1 0 00
1 5 00
0 .2
5 00
K /W
3 x IRK.162.. Series 0 .3 K
/W
Three Phase Brid ge
0.
C onnected
6 K /W
T J = 12 5 C
2 50
0
0
50 1 0 0 15 0 2 00 25 0 3 0 0 3 5 0 4 00 4050
Tota l Output C urrent (A)
25
50
75
100
125
10
www.irf.com
10000
1000
T J = 25C
T J= 125C
100
10
IRK.136.. Series
Per Junction
1000
T = 125C
J
100
10
IRK.142.. Series
Per Junction
1
0
1
Transient Thermal Impedance Z thJC
10000
1000
TJ = 25C
TJ = 125C
100
10
IRK.162.. Series
Per Junction
1
0
1
2
3
4
5
Instantaneous On-state Voltage (V)
0.1
0.01
IRK.136.. Series
0.01
0.1
1
Square Wave Pulse Duration (s)
10
1
Steady State Value
(DC Operation)
0.1
IRK.142.. Series
0.1
1
Square Wave Pulse Duration (s)
10
www.irf.com
(DC Operation)
0.01
0.01
0.001
0.001
TJ = 25C
0.1
IRK.162.. Series
0.01
0.01
0.1
1
Square Wave Pulse Duration (s)
10
11
10
(1)
(2)
(3)
(4)
PG M
PG M
PG M
PG M
=
=
=
=
200 W , tp = 300 s
60 W , tp = 1 m s
30 W , tp = 2 m s
12 W , tp = 5 m s
(4)
(3 ) (2)
(a)
(b )
TJ = -40 C
TJ = 12 5 C
TJ = 25 C
1 00
(1)
VG D
IG D
0 .1
0 .0 0 1
0.0 1
10
100
1 00 0
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
TAC Fax: (310) 252-7309
Visit us at www.irf.com for sales contact information. 03/02
12