SCHEDULE OF RATES
FOR CIVIL WORKS
60
Description of Item
Unit
Unit Rate
Unit
Unit Rate
Description of Item
Erection and maintenance of site office and removal the same after completion
of work in accordance with the conditions of contract. In addition to the office
required for his own use, the Contractor shall provide and maintain furnished field
office for the use of the Engineer and his staff. The field office is to have a concrete
floor, adequate foundation, brick walls, false ceiling of hard board with seasoned
Garjan wood frame and painted, and all windows are to be glazed and provided with
steel grill. Outside and inside wall surface are to be painted on plaster acceptable to
the Engineer. The field office shall be maintained in a secure and watertight condition
by the Contractor until the completion of the contract and shall be provided with
electricity, running water and sewerage. All doors shall be fitted with approved locks
and windows shall be provided with screen/blinds. Before construction the Contractor
shall submit plans and drawings showing proposed details and location for the field
office, including foundations, access roads, shades, layout of electrical and water
supply and hard standings thereto for the approval of the engineer. The Engineer
may require revision of the plans prior to giving approval for construction. The
Contractor shall also submit details proposed furniture, fittings and other items of
equipment and plant to the engineer for approval. These items shall be of the
standard quality suitable for site. The office, complete with furnishings, fittings,
access roads and hard standings shall be ready for occupation by the Engineer
within 28 days of the date when the Contractor first occupies the site. The Contractor
will provide day and night guards and a tea boy for the field office. At the end of the
project all materials, equipment and plant, furniture, fittings recovered from
dismantling the office and removing access road will be the property of the
Contractor. No interim payment shall be certified unless Engineers office with
required facilities are constructed and accepted by the Engineer.
(This is a time related item. Proportionate payment for this item shall be made
distributing in each bill on the basis of percentage progress of the whole works under
contract)
01.1.1
Engineers site office of minimum 15 sqm plinth area with providing furniture, first aidbox, safety helmet, level / theodolite, consumables, stationeries etc.
L.S.
Tk.
125,251.00
01.1.2
Engineers site office of minimum 38 sqm plinth area with providing security fencing,
5 Kva stand-bye generator, furniture, first aid-box, safety helmet, level / theodolite,
consumables, stationeries etc.
L.S.
Tk.
389,014.00
01.1.3
Engineers site office of minimum 38 sqm plinth area with providing security fencing,
5 Kva stand-bye generator, IBM compatible PC with monitor, uninterruptible power
supply (UPS), Laserjet printer (minimum 25 ppm), furniture, first aid-box, safety
helmet, level/theodolite/EDM, consumables, stationeries etc.
L.S.
Tk.
502,145.00
01.1.4
Engineers site office of minimum 38 sqm plinth area with providing security fencing,
5 Kva stand-bye generator, IBM compatible PC with monitor, uninterruptible power
supply (UPS), Laserjet printer (minimum 25 ppm), photocopier, 6 cft. Freeze,
furniture, first aid-box, safety helmet, level/theodolite/EDM, consumables,
stationeries etc.
L.S.
Tk.
534,467.00
Item No.
61
Description of Item
Unit
Unit Rate
01.1.5
Engineers site office of minimum 10 sqm plinth area with providing furniture, first aidbox, safety helmet, consumables, stationeries etc for low value simple work of short
duration (not more than six months).
L.S.
Tk.
23,916.00
01.1.6
each
Tk.
52,871.00
01.1.7
Providing and maintenance one project profile signboards of the size not
exceeding 1 m x 2 m, to be placed at a suitable place of the site including
submission of proposals for the materials of the signboards and text layout to the
Engineer for approval which will be positioned as directed by the Engineer and
removing the same on completion of the Works or as instructed by the Engineer.
sqm.
Tk.
207.00
01.2.1
Per
tender
Tk.
19,451.00
The as-built drawings must show the permanent works as actually constructed and
reflect the revision of Tender Drawings and Drawings supplied to the Contractor
during the Contract as well as revisions of drawings supplied by the Contractor
during the Contract.
(One set of as-built drawings shall be considered for measurement and payment)
01.2.2
sqm of
drawing
sheet
Tk.
267.00
01.2.3
Providing minimum ten (10) copies coloured post-card size progress photograph of
works under contract taken by professional photographer which record the progress
of the Works.
month
Tk.
42.00
01.2.4
Per
tender
Tk.
29,165.00
01.2.5
month
Tk.
12,371.00
Item No.
62
Description of Item
Unit
01.2.6
month
Tk.
1,802.00
01.3
Providing layout and carry over PWD Bench-Mark (BM) at site from nearby BM
pillar, Property lines, existing ground level (EGL), formation ground level (FGL),
highest flood levels (HFL), plinth levels (PL), mean sea level (MSL), setting and
marking all pillars, marker, pegs etc. showing and maintaining reduced levels (RLs)
including locating, establishing, protecting all public utilities within the premise of
work and finally all to be presented in black and white.
sqm.
Tk.
4.00
01.4
Mobilization and cleaning site before commencing actual physical work and during
contract period and demobilization after completion of the Works under contract
accepted by Engineer.This work shall also covers clayey cleaning and clearing,
cutting or filling, dressing the project area on and in the ground to an extent that all
the events of works of the project can be executed smoothly in a working
environment with a particular attention on safety and security in all respects, and to
stockpile the end outcome to a place for disposal agreed by the Engineer, where,
payments are to be based on ground area determined by the Engineer and be
proportionate to the percentage progress of work under contract as a whole in all
respects and approved by the Engineer.
sqm.
Tk.
21.00
1.5
Providing Expertised architect having relevant experience (s) more than 5years for
detail documentation of architectural themes, drawings, workingout shop drawings,
communication with theme architect & getting approval , specifying architectural
needs according to approved master architectural themes & plan, certifying as built
drawing for the approval etc & jobs assigned by the HOPE or his official at site
(max man month not greater than 1/4th of Project duration & payment for the item
subject to submission of CV & approved by approving authority)
Per
month
Tk.
60,000.00
1.6
Providing Expertised Engneer having relevant experience(s) more than 10years, for
the project documentation, progress study & adjustment, preparation of project
Material schedule and Testing schdule for approval etc. & jobs assigned by the
HOPE or his official, at site (max man month not greater than 1/4th of Project
duration & payment for the item subject to submission of CV & approved by
approving authority)
Per
month
Tk.
100,000.00
1.7
Pick - up (double Cab) for transport of Test samples, work samples & emmergency
services etc. in/c fuel etc. (total usage not more than 1/6th of project duration.)
Per
month
Tk.
65,000.00
Unit Rate
Item No.
63
Description of Item
Unit
Unit Rate
Unit
Unit Rate
Description of Item
02.1
Earth work in excavation in all kinds of soil for foundation trenches including.
layout, providing center lines, local bench-mark pillars, leveling, ramming and
preparing the base, fixing bamboo spikes and marking layout with chalk powder,
providing necessary tools and plants, protecting and maintaining the trench dry etc.,
stacking, cleaning the excavated earth at a safe distance out of the area enclosed by
the layout etc. all complete and accepted by the Engineer, subject to submit method
statement of carrying out excavation work to the Engineer for approval. However,
Engineers approval shall not relieve the contractor of his responsibilities and
obligations under the contract.
02.1.1
sqm.
Tk.
11.00
02.1.2
cum
Tk.
67.00
02.1.3
cum
Tk.
96.00
02.1.4
cum
Tk.
144.00
02.1.5
cum
Tk.
166.00
02.1.6
Extra rate for each additional 0.5 meter depth exceeding 1.5 meter.
cum
Tk.
16.00
02.1.7
cum
Tk.
2.12
02.2
hour
Tk.
333.00
02.3
rm.
Tk.
75.00
02.4
Supplying wooden ballah having an average diameter not less than 150 mm
(without barks) at one third distance from larger end with a minimum end diameter of
100 mm for retaining purpose and driving to a depth as per design and drawing by
any method including all arrangement for staging, hoisting, carrying etc. complete
and accepted by the Engineer.
rm.
Tk.
714.00
Item No.
64
Description of Item
Unit
Unit Rate
02.5
Palisading work by supplying bitumen drum sheet walling tied with 20 BWG G.I.
wire fixing the same with already driven borrak bamboo posts with half split borrak
bamboo runners @ 450mm c/c horizontally with iron nails, G.I wire etc. all complete
and accepted by the Engineer. (Rate is excluding the cost of bamboo post).
sqm.
Tk.
596.00
02.6
rm.
Tk.
269.00
02.7.1
sqm.
Tk.
678.00
02.7.2
Shore protection work during excavation in foundation trenches to protect loss due
to damage of property by Palisading beyond 1.5 m depth accepted by the
Engineer [the rate is including cost of vertical post]
sqm.
Tk.
1,217.00
02.8
sqm.
Tk.
130.00
02.9
Removing sludge or semi-liquid clay/substances etc not suitable for pumping out
or carrying by head load from the bottom of any marshy land, lake, ditch, pond by
mixing fine local sand of F.M. 0.8 or less to a proportion such that it can be carried to
an intermediate point of disposal and cutting the same including stacking and
spreading properly on a suitable place to dry in the sun for a certain days and
dispose the dried sludge or clay to a safe distance etc. complete and accepted by
the Engineer subject to submit method statement to the Engineer for carrying out the
works including ultimate disposal of the sludge under this item for approval. However
Engineers approval shall not relieve the Contractor of his responsibilities and
obligations under the contract.
cum
Tk.
678.00
02.10.1
Sand filling in foundation trenches and plinth with sand having F.M. 0.5 to 0.8 in
150mm layers including leveling, watering and compaction to achieve minimum dry
density of 90% with optimum moisture content (Modified proctor test) by ramming
each layer up to finished level as per design supplied by the design office only etc. all
complete and accepted by the Engineer.
cum
Tk.
602.00
02.10.2
Sand filling in foundation trenches and plinth with coarse sand having min. F.M. 1.2
in 150mm in layers including leveling, watering and compaction to achieve minimum
dry density of 90% with optimum moisture content (Modified proctor test) by ramming
each layer up to finished level as per design supplied by the design office only etc. all
complete and accepted by the Engineer.
cum
Tk.
1,043.00
02.10.3
Sand filling in foundation trenches and plinth with coarse sand having min. F.M. 2.2
in 150mm layers including leveling, watering and compaction to achieve minimum
dry density of 90% with optimum moisture content (Modified proctor test) by ramming
each layer up to finished level as per design supplied by the design office only etc. all
complete and accepted by the Engineer.
cum
Tk.
1,760.00
Item No.
65
Description of Item
Unit
Unit Rate
02.11
cum
Tk.
3,652.00
02.12
cum
Tk.
4,508.00
02.13
Earth filling in foundation trenches and plinth in 150 mm layer with earth available
within 90 m of the building site to achive minimum dry density of 90% with
optimum moisture content (Modified proctor test) including carrying watering,
leveling, dressing and compacting to a specified percentage each layer up to finished
level etc. all complete and accepted by the Engineer.
cum
Tk.
114.00
02.14
Clearing and disposing of excavated earth from the construction site by truck or
any other means to a place within 30 km radius of the city or town area including
loading, unloading at both ends, leveling and dressing the carried earth etc. complete
accepted by the Engineer.
cum
Tk.
457.00
02.15
Earth filling in foundation trenches and plinth in 150 mm layers with carted earth
carried by truck or any other means loading and unloading at both ends including
leveling, watering and compacting to achive minimum dry density of 90% with
optimum moisture content (modified proctor test) including local carriage each layer
up to finished level including cost of water and test (carried from beyond 300 m) etc.
all complete and accepted by the Engineer.
02.15.1
cum
Tk.
443.00
02.15.2
cum
Tk.
367.00
02.15.3
cum
Tk.
329.00
02.15.4
For other than Dhaka, Ctg., Sylhet, Rajshahi, Barishal, Khulna metropolitan area and
N'ganj district
cum
Tk.
291.00
02.16
02.16.1
02.16.1.1
cum
Tk.
441.73
02.16.1.2
cum
Tk.
265.00
02.16.2
Item No.
66
Description of Item
Unit
Unit Rate
02.16.2.1
cum
Tk.
284.25
02.16.2.2
By Dredging
cum
Tk.
188.00
02.16.3
02.16.3.1
cum
Tk.
250.70
02.16.3.2
By Dredging
cum
Tk.
164.00
02.16.4
For other than Dhaka, Ctg., Sylhet, Rajshahi, Barishal, Khulna metropolitan area and
N'ganj district
02.16.4.1
cum
Tk.
217.16
02.16.4.2
By Dredging
cum
Tk.
140.00
02.17
cum
Tk.
364.00
Item No.
67
Description of Item
Unit
Unit Rate
Description of Item
Unit
Unit Rate
03.1
One layer of brick flat soling in foundation or in floor with first class or picked
jhama bricks including preparation of bed and filling the interstices with local sand,
leveling etc. complete and accepted by the Engineer.
sqm.
Tk.
355.00
03.2
One layer of Herring bone bond (HBB) brick soling in foundation or in floor with
first class or picked jhama bricks including preparation of bed and filling the
interstices with local sand, leveling including the supply of water,other charges, costs
of tools and plants etc. all complete and accepted by the Engineer.
sqm.
Tk.
562.00
03.3
Brick on end edging including preparation of bed and filling the interstices with local
sand, leveling, maintaining alignment grid etc. all complete and accepted by the
Engineer.
rm.
Tk.
88.00
03.4
Mass concrete (1:3:6) in foundation or floor with cement, sand (F.M. 1.2) and
picked jhama chips including breaking chips, screening, mixing, laying, compacting
to levels and curing for at least 7 days including the supply of water, electricity and
other charges and costs of tools and plants etc. all complete and accepted by the
Engineer. (Cement: CEM-II/A-M)
03.4.1
Mass concrete in foundation (1:3:6) with cement, brick chips and sand of F.M. 1.2
cum
Tk.
6,319.00
03.4.2
Mass concrete in floor (1:3:6) with cement brick chips and sand of F.M. 1.2
cum
Tk.
6,241.00
03.5
Mass concrete (1:2:4) in foundation or floor with cement, sand (F.M. 1.2) and
picked jhama chips including breaking chips, screening, mixing, laying, compacting
to levels and curing for at least 7 days including the supply of water, electricity and
other charges and costs of tools and plants etc. all complete and accepted by the
Engineer. (Cement: CEM-II/A-M)
03.5.1
Mass concrete in foundation (1:2:4) with brick chips and local sand of F.M. 1.2
cum
Tk.
7,481.00
03.5.2
Mass concrete in floor (1:2:4) with brick chips and local sand of F.M. 1.2
cum
Tk.
7,403.00
03.6
Damp proof course (DPC) (1:1.5:3) in cement concrete with cement, sand (F.M.
1.2) and picked jhama or stone chips including breaking chips, screening, centering,
shuttering, casting, curing and finished with a coat of bitumen including the supply of
water, electricity and other charges and costs of tools and plants etc. all complete
and accepted by the Engineer. (Cement: CEM-II/A-M)
03.6.1
75 mm or 3" thick damp proof course (1:1.5:3) with brick chips and 50% Sylhet
sand (F.M. 2.2) and 50% local sand (F.M. 1.2)
sqm.
Tk.
1,002.00
03.6.2
75 mm or 3" thick damp proof course (1:1.5:3) with Sylhet sand (F.M. 2.2) and
stone chips.
sqm.
Tk.
1,174.00
03.6.3
150 mm or 6" thick damp proof course (1:1.5:3) with Sylhet sand (F.M. 2.2) stone
chips and water-proofing admixture/agent approved by the Engineer.
cum
Tk.
12,711.00
03.7
Supplying and laying of single layer polythene sheet weighing one kilogram per 6.5
square meter in floor or any where below cement concrete complete in all respect
and accepted by the Engineer.
sqm.
Tk.
34.00
Item No.
68
Description of Item
Unit
Unit Rate
Description of Item
Unit
Unit Rate
04.1
Brick works with first class bricks in cement sand (F.M. of sand 1.2) mortar (1:6)
in foundation and plinth, filling the joints/interstices fully with mortar, racking out the
joints, cleaning and soaking the bricks at least for 24 hours before use and curing at
least for 7 days etc. all complete including cost of water, electricity and other charges
and accepted by the Engineer. (Cement: CEM-II/A-M)
cum
Tk.
5,327.00
04.2
Brick works of width one brick or one and a half brick length with first class
bricks in cement sand (F.M. 1.2) mortar (1:6) in superstructure including raking
out joints, filling the interstices with mortar, cleaning and soaking the bricks at least
for 24 hours before use and washing of sand, necessary scaffolding, curing at least
for 7 days etc. all complete (measurement to given as 250 mm width for one brick
length and 375 mm for one brick and a half brick length) and accepted by the
Engineer.(Cement: CEM-II/A-M)In ground floor
cum
Tk.
5,637.00
04.3
Brick works with first class bricks in cement sand (F.M. 1.2) mortar (1:4) in
exterior walls including filling the interstices with mortar, raking out joints, cleaning
and socking the bricks at least for 24 hours before use and washing of sand,
necessary scaffolding, curing at least for 7 days etc. all complete including cost of
water, electricity and other charges (measurement to given as 250 mm width for one
brick length and 375 mm for one brick and a half brick length) accepted by the
Engineer. (Cement: CEM-II/A-M). In ground floor
cum
Tk.
6,013.00
04.4
Exposed brick works (for exterior wall without outside plaster) with special
quality sorted out first class bricks, very carefully laid in cement sand (F.M. 1.2)
mortar (1:4)) in superstructure with uniform width and depth joints, true to vertical
and horizontal lines including raking out joints scaffolding, soaking the bricks at least
for 24 hours before use, washing and screening of sand. Curing at least for 7 days
and high class flush pointing with cement sand (F.M. 1.2) mortar (1:1) including cost
of water, electricity and other charges etc all complete and accepted by the
Engineer. (Cement: CEM-II/A-M). In ground floor
cum
Tk.
6,984.00
04.5
Exposed brick works (for exterior wall without outside plaster) with automatic
machine made first class bricks, very carefully laid in cement sand (F.M. 1.2)
mortar (1:4)) in superstructure with uniform width and depth joints, true to vertical
and horizontal lines including raking out joints scaffolding, soaking the bricks at least
for 24 hours before use, washing and screening of sand. Curing at least for 7 days
and high class flush pointing with cement sand (F.M. 1.2) mortar (1:1) including cost
of water, electricity and other charges etc all complete and accepted by the
Engineer. (Cement: CEM-II/A-M). In ground floor
cum
Tk.
6,984.00
04.6
Brick works with 10 holes machine made bricks of approved size (9.5" x 4.5" x
2.75") having uniform colour carefully laid in cement sand (F.M. 1.2) mortar (1:4) in
superstructure with uniform width and depth joints, true to vertical and horizontal
lines including raking out joints, filling the interstices with mortar, cleaning and
soaking bricks at least for 24 hours before use and washing and screening of sand,
necessary scaffolding, curing at least for 7 days and pointing with cement sand (F.M.
1.2) mortar (1:2) including cost of water, electricity and other charges etc. complete
and accepted by the Engineer. (Cement: CEM-II/A-M) In ground floor
cum
Tk.
10,950.00
Item No.
69
Description of Item
Unit
Unit Rate
04.7
Brick work with 9.5" x 4.5" x 2.75" size machine made solid klinker facing
bricks having uniform colour carefully laid in cement sand (F.M. 1.2) mortar (1:4) in
superstructure with uniform width and depth joints, true to vertical and horizontal
lines including raking out joints, filling the interstices with mortar, cleaning and
soaking bricks at least for 24 hours before use and washing and screening of sand,
necessary scaffolding, curing at least for 7 days and pointing with cement sand (F.M.
1.2) mortar (1:2) including cost of water, electricity and other charges etc. complete
and accepted by the Engineer.(Cement: CEM-II/A-M)In ground floor
cum
Tk.
8,874.00
04.8
Brick works with 9.5" x 4.5" x 2.75" size 10 hole machine made Rock-face or
textured klinker facing bricks having uniform colour carefully laid in cement sand
(F.M. 1.2) mortar (1:4) in superstructure with uniform width and depth joints, true to
vertical and horizontal lines including raking out joints, filling the interstices with
mortar, cleaning and soaking bricks at least for 24 hours before use and washing
and screening of sand, necessary scaffolding, curing at least for 7 days and pointing
with cement sand (F.M. 1.2) mortar (1:2) including cost of water, electricity and other
charges etc. all complete and accepted by the Engineer. (Cement: CEM-II/A-M)
In ground floor
cum
Tk.
8,757.00
04.9
Brick works with 9.5" x 4.5" x 2.75" size 3 hole machine made reinforced
klinker facing bricks having uniform colour carefully laid in cement sand (F.M.1.2)
mortar (1:4) in superstructure with uniform width and depth joints, true to vertical
and horizontal lines including raking out joints, filling the interstices with mortar,
cleaning and soaking bricks at least for 24 hours before use and washing and
screening of sand, necessary scaffolding, curing at least for 7 days and pointing with
cement sand (F.M. 1.2) mortar (1:2) including cost of water, electricity and other
charges etc. all complete and accepted by the Engineer. (Cement: CEM-II/A-M) In
ground floor
cum
Tk.
12,296.00
04.10
Extra cost shall be incorporated in the estimate for each additional floor for brick
works (item No.- 4.2 to 4.9)
04.10.1
cum
Tk.
130.00
04.10.2
Add for each additional floor from 6th floor to 9th floor
cum
Tk.
182.00
04.10.3
Add for each additional floor for 10th floor and above
cum
Tk.
208.00
04.11
Extra cost for brick-work for each additional meter (or part of meter) free
height of brick wall beyond 4 m from the respective floor in auditorium, go-down,
overhead water tank etc. as description of the item No. in 16, 17, 18 and 19 including
cost of water, electricity and other charges etc. all complete and accepted by the
Engineer. (Extra cost shall be incorporated in the estimate only when both sides of
wall is uninterruptedly free beyond 4.00 meter)
cum
Tk.
136.00
04.12
Providing brick works for 200 x 100 mm facing in superstructure with 200 x 100
x 50 mm machine made klinker hard pressed facing bricks of approved quality in
cement sand (F.M. 1.2) mortar (1:4), including racking out joints, cutting the bricks to
required size wherever necessary including high class recessed pointing, cleaning
and soaking the bricks at least for 24 hours before use and washing and screening of
sand, necessary scaffolding, curing at least for 7 days for all floors up to 4th floor
including cost of water, electricity and other charges etc. all complete and accepted
by the Engineer.(100 x 200 mm face should be placed for facing).(Cement: CEMII/A-M)In ground floor
sqm.
Tk.
1,586.00
Item No.
70
Description of Item
Unit
Unit Rate
04.13
sqm.
Tk.
2,091.00
04.14
sqm.
Tk.
2,065.00
04.15
125 mm brick work with first class bricks in cement sand (F.M. 1.2) mortar (1:6)
and making bond with connected walls including necessary scaffolding, raking out
joints, cleaning and soaking the bricks for at least 24 hours before use and washing
of sand curing at least for 7 days in all floors including cost of water, electricity and
other charges etc. all complete and accepted by the Engineer. (Cement: CEM-II/AM) In ground floor
sqm.
Tk.
798.00
04.16
125 mm brick works with first class bricks in cement sand (F.M. 1.2) mortar (1:4)
and making bond with connected walls including necessary scaffolding, raking out
joints, cleaning and soaking the bricks for at least 24 hours before use and washing
of sand curing at least for 7 days in all floors including cost of water, electricity and
other charges etc. all complete and accepted by the Engineer. (Cement: CEM-II/AM) In ground floor
sqm.
Tk.
837.00
04.17
Exposed 125 mm thick pointing extra ordinary ornamental brick work with
sorted out first class bricks in cement sand (F.M. 1.2) mortar (1:4) and making
bond with connected walls including necessary scaffolding, raking out joints, cleaning
and soaking the bricks for at least 24 hours before use and washing of sand curing at
least for 7 days in all floors including cost of water, electricity and other charges etc.
all complete and accepted by the Engineer.(Cement: CEM-II/A-M)In ground floor
sqm.
Tk.
1,016.00
04.18
Exposed 125 mm thick pointing extra ordinary ornamental brick work with
automatic machine made first class bricks in cement sand (F.M. 1.2) mortar (1:4)
and making bond with connected walls including necessary scaffolding, raking out
joints, cleaning and soaking the bricks for at least 24 hours before use and washing
of sand curing at least for 7 days in all floors including cost of water, electricity and
other charges etc. all complete and accepted by the Engineer. (Cement: CEM-II/AM) In ground floor
sqm.
Tk.
1,030.00
Item No.
71
Description of Item
Unit
Unit Rate
04.19
Providing 125 mm thick (Partition walls) brick work in superstructure brick work
(1:4) in cement sand (F.M. 1.2) mortar with 10 hole machine made ceramic
bricks of approved size having uniform colour, carefully laid in cement mortar and
depth joints true to vertical and horizontal lines including. racking out joints, filling the
interstices with same mortar, making bond with connected walls, cleaning, soaking
brick at least 24 hours and washing of sand, curing 7 days in all floors, including cost
of water, electricity and other charges accepted by the Engineer. (Cement: CEM-II/AM) In ground floor
sqm.
Tk.
1,499.00
04.20
Fancy screen work with different size hollow machine made design blocks with
uniform colour, carefully laid in coloured cement sand (F.M. 1.2) mortar (1:3) in all
floors in wall with uniform mortar joints, true to vertical and horizontal line including
racking out joints, cleaning and soaking the blocks for minimum 24 hours before use
including washing and screening of sand, scaffolding, curing etc. complete in all
respect including supply of all necessary materials including cost of water, electricity
and other charges accepted by the Engineer. (Cement: CEM-II/A-M)
04.20.1
With design block No. 3 (MCW) size: 4" x 4" x 4" or equivalent volume & design
In ground floor
sqm.
Tk.
4,102.00
04.20.2
With design block No. 1 (MCW) size: 5.5" x 5.5" x 4" or equivalent volume & design
In ground floor
sqm.
Tk.
2,403.00
04.20.3
With design block No. 20 (MCW) size: 6" x 6" x 4" or equivalent volume and design
In ground floor
sqm.
Tk.
2,323.00
04.21
Extra cost shall be incorporated in the estimate for each additional floor for brick
and screen block works (item No.- 4.12 to 4.20)
04.21.1
sqm.
Tk.
24.00
04.21.2
Add for each additional floor from 6th floor to 9th floor
sqm.
Tk.
32.00
04.21.3
Add for each additional floor for 10th floor and above
sqm.
Tk.
40.00
04.22
Klinker paving brick works in floor or pavement with machine made pressed bricks
of approved quality in cement sand (F.M. 1.2) mortar (1:4) on minimum 12 mm thick
cement sand (F.M. 1.2) mortar (1:4) including raking out joints, cutting the bricks to
required size soaking the same 24 hours before use wherever necessary including
high class flush pointing in cement mortar (1:2), cleaning, curing at least for 7 days
etc. including washing and screening of sand, cost of water, electricity and other
charges complete and standard practice accepted by the Engineer.(Cement: CEMII/A-M)
04.22.1
100 mm thick brick on edge pavement with 200 x 100 x 50 mm size klinker facing
bricks.
sqm.
Tk.
2,599.00
04.22.2
50 mm thick flat brick pavement with 200 x 100 x 50 mm klinker paving bricks in 1:4
cement sand mortar having 200 x 100 mm face at top.
sqm.
Tk.
1,523.00
04.22.3
sqm.
Tk.
2,013.00
Item No.
72
Description of Item
Unit
Unit Rate
04.23
125 mm thick brick pavement or flooring with first class brick on edge in cement
sand (F.M. 1.2) mortar (1:4) on minimum 12 mm thick cement sand (F.M. 1.2) mortar
(1:4) including cutting the bricks as per requirement, cleaning and racking out joints,
finishing with flush pointing with cement sand (F.M. 1.2) mortar (1:2) and curing for at
least 7 days etc. including cost of water, washing and screening of sand (F.M. 1.2),
electricity and other charges complete and standard practice accepted by the
Engineer. (Cement: CEM-II/A-M)
sqm.
Tk.
943.00
04.24
sqm.
Tk.
1,578.00
04.25
75 mm thick cement concrete (1:3:6) with cement in flooring best quality coarse
sand and 19 mm down graded picked chips including breaking chips, screening,
mixing, laying, compacting, washing and screening of sand of F.M 1.2 and curing at
least for 7 days etc. including cost of water, electricity and other charges etc. all
complete and accepted by the Engineer. Cement: CEM-II/A-M)
sqm.
Tk.
526.00
04.26
25 mm thick artificial patent stone (1:2:4) flooring with cement, best quality coarse
sand (50% quantity of Sylhet sand or coarse sand of equivalent F.M. 2.2 and 50%
best local sand of FM 1.2) and 12 mm down well graded brick chips including
breaking chips, screening, laying the concrete in alternate panels, compacting and
finishing the top with neat cement and curing at least 7 days in all floors including
cost of water, electricity and other charges etc. all complete and accepted by the
Engineer.(Cement: CEM-II/A-M)In ground floor
sqm.
Tk.
332.00
04.27
38 mm thick artificial patent stone (1:2:4) flooring with cement, best quality coarse
sand (50% quantity of Sylhet sand or coarse sand of equivalent F.M. 2.2 and 50%
best local sand of FM 1.2) and 12 mm down well graded brick chips including
breaking chips, screening, laying the concrete in alternate panels, compacting and
finishing the top with neat cement and curing at least 7 days in all floors including
cost of water, electricity and other charges etc. all complete and accepted by the
Engineer. (Cement: CEM-II/A-M) In ground floor
sqm.
Tk.
423.00
04.28
25 mm thick artificial patent stone (1:2:4) flooring with cement, best quality coarse
sand (50% quantity of Sylhet sand or coarse sand of equivalent F.M. 2.2 and 50%
best local sand of FM 1.2) and 12 mm down well graded stone chips, laying the
concrete in alternate panels, compacting and finishing the top with neat cement and
curing at least 7 days in all floors including cost of water, electricity and other
charges etc. all complete and accepted by the Engineer. (Cement: CEM-II/A-M)
In ground floor
sqm.
Tk.
390.00
04.29
38 mm thick artificial patent stone (1:2:4) flooring with cement, best quality coarse
sand (50% quantity of Sylhet sand or coarse sand of equivalent F.M. 2.2 and 50%
best local sand of FM 1.2) and 12 mm down well graded stone chips, laying the
concrete in alternate panels, compacting and finishing the top with neat cement and
curing at least 7 days in all floors including cost of water, electricity and other
charges
etc.
all
complete
and
accepted
by
the
Engineer.
Cement: (CEM-II/A-M) In ground floor
sqm.
Tk.
510.00
Item No.
73
Description of Item
Unit
04.30
25 mm thick artificial patent stone (1:1.5:3) flooring with cement, best quality
coarse sand (50% quantity of Sylhet sand or coarse sand of equivalent F.M. 2.2 and
50% best local sand of FM 1.2) and 12 mm down well graded stone chips, laying
the concrete in alternate panels, compacting and finishing the top with neat cement
and curing at least 7 days in all floors including cost of water, electricity and other
charges etc. all complete and accepted by the Engineer. (Cement: CEM-II/A-M) In
ground floor
sqm.
Tk.
409.00
04.31
38 mm thick artificial patent stone (1:1.5:3) flooring with cement, best quality
coarse sand (50% quantity of Sylhet sand or coarse sand of equivalent F.M. 2.2 and
50% best local sand of FM 1.2) and 12 mm down well graded stone chips, laying
the concrete in alternate panels, compacting and finishing the top with neat cement
and curing at least 7 days in all floors including cost of water, electricity and other
charges etc. all complete and accepted by the Engineer.(Cement: CEM-II/A-M)In
ground floor
sqm.
Tk.
539.00
04.32
Extra cost shall be incorporated in the estimate for each additional floor for patent
stone works.
04.32.1
sqm.
Tk.
24.00
04.32.2
Add for each additional floor from 6th floor to 9th floor
sqm.
Tk.
32.00
04.32.3
Add for each additional floor for 10th floor and above
sqm.
Tk.
40.00
Unit Rate
Item No.
74
Description of Item
Unit
Unit Rate
Unit
Unit Rate
Description of Item
05.1
10 mm thick finished and 12 mm laying thickness situ mosaic work on floor with
one part of 10 mm machine crushed well graded dust free and properly washed
marble chips and one part of mixture containing white cement / grey cement
including preparation of mix. and laying the same over minimum 25 mm thick artificial
patent stone flooring with brick chips (1:2:4) including making suitable panel,
compacting, curing at least for 7 days, cutting with pumic stone (No. 40, No. 80,
No.120)/cutting with mosaic machine and finishing with Minar stone and spreading
oxalic acid including breaking brick chips, screening, washing mosaic chips and
supply of all necessary materials and water, electricity and other charges in all
respect accepted by the Engineer. (Cement: CEM-II/A-M)
05.1.1
and
glass
strip
using
100%
white
cement.
sqm.
Tk.
1,500.00
05.1.2
With Indian
In ground floor
and
glass
strip
using
100%
grey
cement.
sqm.
Tk.
1,233.00
05.1.3
With Pakistani
In ground floor
using
100%
white
cement.
sqm.
Tk.
1,533.00
05.1.4
With Indian chips and without glass strip using 100% white cement.
In ground floor
sqm.
Tk.
1,315.00
05.1.5
With Indian chips and without glass strip using 100% grey cement.In ground floor
sqm.
Tk.
1,109.00
05.1.6
With Pakistani chips and without glass strip using 100% white cement.
In ground floor
sqm.
Tk.
1,347.00
05.2
12 mm thick finished and laying thickness 14.5 mm cast in situ mosaic work on
floor with one part of 10 mm machine crushed well graded dust free and properly
washed marble chips and one part of mixture containing 100% white cement
including preparation of mix and laying the same over minimum 25 mm thick artificial
patent stone flooring with brick-chips (1:2:4) including making suitable panel,
compacting, curing at least for 7 days, cutting with pumic stone (No. 40, No. 80, No.
120)/ mosaic cutting machine and finishing with Minar stone including breaking brick
chips screening, spreading oxalic acid, washing mosaic chips and supply of all
necessary materials and water, electricity and other charges in all respect accepted
by the Engineer. (Cement: CEM-II/A-M)
05.2.1
sqm.
Tk.
1,582.00
05.2.2
sqm.
Tk.
1,618.00
05.2.3
sqm.
Tk.
1,396.00
05.2.4
sqm.
Tk.
1,432.00
chips
chips
and
glass
strip
Item No.
75
Description of Item
Unit
Unit Rate
05.3
10 mm thick finished and laying thickness 12.5 mm silver grey situ mosaic work
on floor with one part of 10 mm machine crushed well graded, dust free and
properly washed marble chips and one part of mixture containing white cement and
grey cement in proportion (1:1) including preparation of mix and laying the same
over minimum 25 mm thick artificial patent stone flooring with brick-chips (1:2:4)
including making suitable panel, compacting, curing at least for 7 days, cutting with
pumic stone (No. 40, No. 80, No. 120) and finishing with Minar stone including
breaking brick chips, screening, washing mosaic chips and supply of all necessary
materials including and water, electricity and other charges in all respect accepted by
the Engineer. (Cement: CEM-II/A-M)
05.3.1
sqm.
Tk.
1,369.00
05.3.2
sqm.
Tk.
1,402.00
05.3.3
sqm.
Tk.
1,184.00
05.3.4
sqm.
Tk.
1,216.00
05.4
12 mm thick finished and laying thickness 14.5 mm silver grey cast in situ mosaic
work on floor with one part of 10 mm machine crushed well graded dust free and
properly washed marble chips and one part of mixture containing white cement dust
free and properly washed marble chips and one part of mixture containing white
cement and grey with cement in proportion (1:1) including. preparation of mix and
laying the same over minimum 25 mm thick artificial patent stone flooring with brickchips (1:2:4) including making suitable panels, compacting, curing at least for 7 days,
cutting with pumic stone (No. 40. No. 80, No. 120) and finishing with Minar stone
including breaking brick chips, screening, washing mosaic chips and supply of all
necessary materials and water, electricity and other charges in all respect accepted
by the Engineer. (Cement: CEM-II/A-M)
05.4.1
sqm.
Tk.
1,435.00
05.4.2
sqm.
Tk.
1,471.00
05.4.3
sqm.
Tk.
1,250.00
05.4.4
sqm.
Tk.
1,286.00
05.5
10 mm thick finished and laying thickness 12.5 mm situ mosaic work on wall with
one part of 10 mm machine crushed well graded dust free and properly washed
marble chips and one part of mixture containing 100% white cement including
preparation of mix and laying the same on 12 mm thick cement plaster (1:4) to wall,
compacting, curing at least for 7 days, cutting with pumic stone (No. 40, No. 80, No.
120) including finishing the corners and edges and also finishing with Minar stone
and supplying all necessary materials in and water, electricity and other charges in
all respect accepted by the Engineer. (Cement: CEM-II/A-M)
Item No.
76
Description of Item
Unit
Unit Rate
05.5.1
sqm.
Tk.
1,461.00
05.5.2
sqm.
Tk.
1,493.00
05.6
10 mm thick finished and laying thickness silver grey situ mosaic work on wall
with one part of 10 mm machine crushed well graded, dust free and properly washed
marble chips and one part of mixture containing white cement and grey cement in
proportion (1:1) including preparation of mix. and laying the same on 12 mm thick
cement plaster (1:4) to wall, compacting, curing at least for 7 days, cutting with pumic
stone (No. 40, No. 80, No 120) including finishing the corners and edges and also
finishing with Minar stone and supplying all necessary materials in and water,
electricity and other charges in all respect accepted by the Engineer. (Cement: CEMII/A-M)
05.6.1
sqm.
Tk.
1,330.00
05.6.2
sqm.
Tk.
1,362.00
05.6.3
sqm.
Tk.
1,199.00
05.7
10 mm thick finished laid in 12.5 mm thickness coloured situ mosaic work in floor
with one part of 10 mm machine crushed well graded, dust free and properly washed
marble chips and one part of mixture containing white and grey cement in proportion
(1:9) and necessary quantity of approved colouring materials including preparation of
mix and laying the same over min 25 mm thick artificial patent stone flooring with
brick-chips (1:2:4) including making suitable panel, compacting, curing at least for 7
days, cutting with pumic stone (No. 40, No. 80, No. 120) and finishing with Minar
stone including breaking brick chips, screening, washing mosaic chips and supply of
all necessary materials in all respects and water, electricity and other charges in all
respect accepted by the Engineer. (Cement: CEM-II/A-M)
05.7.1
sqm.
Tk.
1,557.00
05.7.2
sqm.
Tk.
1,590.00
05.7.3
sqm.
Tk.
1,372.00
05.7.4
sqm.
Tk.
1,273.00
Item No.
77
Description of Item
Unit
Unit Rate
05.8
05.8.1
sqm.
Tk.
1,639.00
05.8.2
sqm.
Tk.
1,675.00
05.8.3
sqm.
Tk.
1,453.00
05.8.4
sqm.
Tk.
1,489.00
05.9
10 mm thick finished and laying thickness 12.5 mm coloured situ mosaic on walls
with one part of 10 mm machine crushed well graded, dust free and properly washed
marble chips and one part of mixture containing white cement and grey cement in
proportion (9:1) and necessary quantity of approved colouring materials including
preparation of mix and laying the same on 12 mm thick cement sand (F.M. 1.2)
plaster (1:4) to walks including compacting, curing at least for 7 days, cutting with
pumic stone (No. 40, No. 80, No. 120) including finishing the corners and edges and
also finishing with Minar stone and supply of all necessary materials etc. and water,
electricity and other charges complete in all respect accepted by the Engineer.
(Cement: CEM-II/A-M)
05.9.1
sqm.
Tk.
1,518.00
05.9.2
sqm.
Tk.
1,550.00
05.10
05.10.1
200 x 200 x 20 mm (finished) mosaic terrazzo tiles flooring with Indian chips.
In ground floor
sqm.
Tk.
1,458.00
Item No.
78
Description of Item
Unit
05.10.2
200 x 200 x 20 mm (finished) mosaic terrazzo tiles flooring with Pakistani chips.
In ground floor
sqm.
Tk.
1,489.00
05.11
Extra cost shall be incorporated in the estimate for mosaic and terrazzo tiles work
above ground floor (item No.- 5.1 to 5.10).
05.11.1
sqm.
Tk.
8.00
05.11.2
sqm.
Tk.
16.00
05.11.3
Add for each additional floor for 10th floor and above
sqm.
Tk.
24.00
Unit Rate
Item No.
79
Description of Item
Unit
Unit Rate
Description of Item
Unit
Unit Rate
06.1
Marble stone flooring with Indian black/ white marble stone of approved quality,
texture and size over 25 mm thick cement sand (F.M. 1.2) mortar (1:2) including.
placing cement slurry below the stone, cutting the marble stone to desired size,
grinding and finishing the edges, setting in position in proper level filling the gaps
with white cement and colouring pigments including supplying all necessary
equipments/materials and finishing the top by pumic stone and necessary auxiliary
materials and water, electricity and other charges complete in all respect accepted
by the Engineer.(Cement: CEM-II/A-M)
06.1.1
sqm.
Tk.
6,277.00
06.1.2
sqm.
Tk.
5,696.00
06.2
Marble stone flooring with Indian coloured/ grey marble stone of approved
quality, texture and size over 25 mm thick cement sand (F.M. 1.2) mortar (1:2)
including. placing cement slurry below the stone, cutting the marble stone to desired
size, grinding and finishing the edges, setting in position in proper level filling the
gaps with white cement and colouring pigments including supplying all necessary
equipments/materials and finishing the top by pumic stone and necessary auxiliary
materials and water, electricity and other charges complete in all respect accepted
by the Engineer. (Cement: CEM-II/A-M)
06.2.1
sqm.
Tk.
6,471.00
06.2.2
sqm.
Tk.
5,825.00
06.3
Supplying and setting Indian marble stone of approved quality, textured and size
on walls over 12 mm thick cement sand (F.M. 1.2) mortar (1:2) including cutting and
grinding the marble stone slab/tile setting in position keeping horizontal and vertical
alignment correct, filling the joints with white cement, cutting and grinding the top
surface, finishing etc including water, electricity and other charges complete in all
respect accepted by the Engineer. (Cement: CEM-II/A-M)
06.3.1
sqm.
Tk.
5,213.00
06.3.2
sqm.
Tk.
5,601.00
06.4
Marble stone flooring with 18mm thick Italian coloured/ grey marble stone of
approved quality, texture and size over 25 mm thick cement sand (F.M. 1.2) mortar
(1:2) including. placing cement slurry below the stone, cutting the marble stone to
desired size, grinding and finishing the edges, setting in position in proper level filling
the gaps with white cement and colouring pigments including supplying all necessary
equipments/materials and finishing the top by pumic stone and necessary auxiliary
materials and water, electricity and other charges complete in all respect accepted
by the Engineer.(Cement: CEM-II/A-M)In ground floor
sqm.
Tk.
8,281.00
Item No.
80
Description of Item
Unit
Unit Rate
06.5
Labour Cost for making moulding in marble stone as per Architectural drawing
including cutting, grinding, finishing, supplying necessary equipment etc. complete in
all respect as per direction of the Engineer in Charge. (Cement: CEM-II/A-M)
06.5.1
rm.
Tk.
343.00
06.5.2
rm.
Tk.
339.00
06.5.3
rm.
Tk.
302.00
06.6
Supplying, fitting and fixing country made glazed wall tiles ,irrespective of color
&/or design, with on 20 mm thick cement sand (F.M. 1.2) mortar (1:3) base and
raking out the joints with repective joint filler & binder including cutting, laying and
hire charge of machine and finishing with care etc. including water, electricity and
other charges complete all respect accepted by the Engineer.
(Cement: CEM-II/A-M). In ground floor
06.6.1
sqm.
Tk.
1,230.00
06.6.2
Wall tiles more than 250x330 & less than 250x400 in sizes or equivalent
sqm.
Tk.
1,339.00
06.6.3
sqm.
Tk.
1,624.00
06.7
06.7.1
sqm.
Tk.
1,455.00
06.7.2
sqm.
Tk.
1,590.00
06.8
06.8.1
sqm.
Tk.
1,509.00
06.8.2
sqm.
Tk.
1,604.00
06.9
Supplying, fitting and fixing countr made mirror polished homogeneous floor tiles
irrespective of color &/or design, with cement sand (F.M. 1.2) mortar (1:4) base
and raking out the joints with white cement including cutting and laying the tiles in
proper way and finishing with care etc. all complete and accepted by the Engineer.
(Cement: CEM-II/A-M) In ground floor
06.9.1
sqm.
Tk.
1,645.00
06.9.2
sqm.
Tk.
1,780.00
06.9.3
sqm.
Tk.
2,038.00
Item No.
81
Description of Item
Unit
06.10
Supplying, fitting and fixing country made GP homogeneous stair tiles irrespective
of color &/or design, with cement sand (F.M. 1.2) mortar (1:4) base and raking out
the joints with white cement including cutting and laying the tiles in proper way and
finishing with care etc. all complete and accepted by the Engineer. (Cement: CEMII/A-M) In ground floor
sqm.
Tk.
1,536.00
06.11
Supplying, fitting and fixing country made floor tiles irrespective of color &/or
design,with adhesives in full thickness of tiles ,filler/tiles grout in/c cutting, shaping,
placing in proper level etc. all complete as direction of the Engineer in charge. In
ground floor
06.11.1
sqm.
Tk.
1,360.00
06.11.1.1
Sqm.
TK.
1,439.00
06.11.2
sqm.
Tk.
1,224.00
06.11.2.1
Sqm.
TK.
1,364.00
06.11.3
sqm.
Tk.
1,374.00
06.11.3.1
Sqm.
TK.
1,432.00
06.11.4
sqm.
Tk.
1,279.00
06.11.4.1
Sqm.
TK.
1,350.00
06.11.5
sqm.
Tk.
1,414.00
06.11.5.1
Sqm.
TK.
1,472.00
06.11.6
sqm.
Tk.
1,550.00
06.11.6.1
Sqm.
TK.
1,635.00
06.11.7
sqm.
Tk.
1,808.00
06.11.7.1
Sqm.
TK.
1,880.00
06.12
Extra Rate for each additional floor for Tiles and Marble Stone Works
06.12.1
sqm.
Tk.
8.00
06.12.2
Add for each addl. floor for 6th floor to 9th floor
sqm.
Tk.
16.00
06.12.3
Add for each addl. floor for 10th floor and above
sqm.
Tk.
24.00
Unit Rate
Item No.
82
Description of Item
Unit
Unit Rate
Description of Item
Unit
Unit Rate
07.1.1
07.1.1.1
Concrete
cum
Tk.
7,319.00
07.1.1.2
sqm.
Tk.
354.00
07.1.2
07.1.2.1
Concrete
cum
Tk.
7,319.00
07.1.2.2
sqm.
Tk.
413.00
07.1.3
In foundation beam
07.1.3.1
Concrete
cum
Tk.
7,319.00
07.1.3.2
sqm.
Tk.
355.00
07.1.4
Padestals, column capitals, lift walls and walls upto Ground Floor
07.1.4.1
Concrete
cum
Tk.
7,420.00
Item No.
83
Description of Item
07.1.4.2
07.1.5
07.1.5.1
Unit
Unit Rate
sqm.
Tk.
412.00
Concrete
cum
Tk.
7,722.00
07.1.5.2
sqm.
Tk.
394.00
07.1.6
Tee beams, Ell beams and Rectangular beams etc upto Ground Floor
07.1.6.1
Concrete
cum
Tk.
7,319.00
07.1.6.2
sqm.
Tk.
485.00
07.1.7
07.1.7.1
Concrete
cum
Tk.
7,319.00
07.1.7.2
sqm.
Tk.
459.00
07.1.8
Cornice, railing, drop walls, louver, fins etc upto Ground Floor
07.1.8.1
Concrete
cum
Tk.
7,587.00
07.1.8.2
sqm.
Tk.
344.00
07.1.9
07.1.9.1
Concrete
cum
Tk.
7,587.00
07.1.9.2
sqm.
Tk.
395.00
07.1.10
07.1.10.1
Concrete
cum
Tk.
7,587.00
07.1.10.2
sqm.
Tk.
381.00
07.1.11
07.1.11.1
Concrete
cum
Tk.
7,587.00
07.1.11.2
sqm.
Tk.
584.00
Item No.
84
Description of Item
Unit
Unit Rate
Reinforced cement concrete works using steel shutter, with minimum cement
content relates to mix ratio 1:2:4 having minimum f 'cr = 24 Mpa, and satisfying a
specified compressive strength f c= 19 Mpa at 28 days on standard cylinders as per
standard practice of Code ACI/BNBC/ASTM & cement conforming to BDS EN-197-1CEM1, 52.5N (52.5MPa) / ASTM-C 150 Type I, best quality sand [50% quantity of
best local sand (F.M. 1.2) and 50% quantity of Sylhet sand or coarse sand of
equivalent F.M. 2.2] and 20 mm down well graded picked jhama brick chips
conforming ASTM C-33 including breaking chips and screening, making, placing
shutter in position and maintaining true to plumb, making shutter water-tight
properly, placing reinforcement in position; mixing in standard mixer machine with
hoper fed by standard measuring boxes, casting in forms, compacting by vibrator
machine and curing at least for 28 days, removing centering-shuttering after
specified time approved; including cost of water, electricity, additional testing
charges of materials and cylinders required by engineer, other charges etc. all
complete approved and accepted by the Engineer. (Rate is excluding the cost of
reinforcement and its fabrication, placing and binding etc)
07.2.1
07.2.1.1
Concrete
cum
Tk.
7,319.00
07.2.1.2
sqm.
Tk.
382.00
07.2.2
07.2.2.1
Concrete
cum
Tk.
7,319.00
07.2.2.2
sqm.
Tk.
391.00
07.2.3
Foundation beam
07.2.3.1
Concrete
cum
Tk.
7,319.00
07.2.3.2
sqm.
Tk.
323.00
07.2.4
Padestals, column, column capitals, lift walla and walls upto Ground Floor
07.2.4.1
Concrete
cum
Tk.
7,420.00
07.2.4.2
sqm.
Tk.
373.00
07.2.5
07.2.5.1
Concrete
cum
Tk.
7,722.00
07.2.5.2
sqm.
Tk.
380.00
07.2.6
Tee beams, Ell beams and Rectangular beams etc upto Ground Floor
07.2.6.1
Concrete
cum
Tk.
7,319.00
Item No.
85
Description of Item
07.2.6.2
07.2.7
07.2.7.1
Unit
Unit Rate
sqm.
Tk.
415.00
Concrete
cum
Tk.
7,319.00
07.2.7.2
sqm.
Tk.
498.00
07.2.8
07.2.8.1
Concrete
cum
Tk.
7,587.00
07.2.8.2
sqm.
Tk.
344.00
07.2.9
07.2.9.1
Concrete
cum
Tk.
7,587.00
07.2.9.2
sqm.
Tk.
410.00
07.2.10
07.2.10.1
Concrete
cum
Tk.
7,587.00
07.2.10.2
sqm.
Tk.
403.00
07.2.11
07.2.11.1
Concrete
cum
Tk.
7,587.00
07.2.11.2
sqm.
Tk.
584.00
07.3.1
Item No.
86
Description of Item
Unit
Unit Rate
07.3.1.1
Concrete
cum
Tk.
10,203.00
07.3.1.2
sqm.
Tk.
354.00
07.3.2
07.3.2.1
Concrete
cum
Tk.
10,203.00
07.3.2.2
sqm.
Tk.
413.00
07.3.3
In foundation beam
07.3.3.1
Concrete
cum
Tk.
10,203.00
07.3.3.2
sqm.
Tk.
355.00
07.3.4
Padestals, column capitals, lift walls and walls upto Ground Floor
07.3.4.1
Concrete
cum
Tk.
10,304.00
07.3.4.2
sqm.
Tk.
412.00
07.3.5
07.3.5.1
Concrete
cum
Tk.
10,607.00
07.3.5.2
sqm.
Tk.
394.00
07.3.6
Tee beams, Ell beams and Rectangular beams etc upto Ground Floor
07.3.6.1
Concrete
cum
Tk.
10,203.00
07.3.6.2
sqm.
Tk.
485.00
07.3.7
07.3.7.1
Concrete
cum
Tk.
10,203.00
07.3.7.2
sqm.
Tk.
459.00
07.3.8
Cornice, railing, drop walls, louver, fins etc upto Ground Floor
07.3.8.1
Concrete
cum
Tk.
10,472.00
07.3.8.2
sqm.
Tk.
344.00
07.3.9
07.3.9.1
Concrete
cum
Tk.
10,472.00
07.3.9.2
sqm.
Tk.
395.00
07.3.10
07.3.10.1
Concrete
cum
Tk.
10,472.00
Item No.
87
Description of Item
07.3.10.2
07.3.11
07.3.1.1
07.3.11.2
Unit
Unit Rate
sqm.
Tk.
381.00
Concrete
cum
Tk.
10,472.00
sqm.
Tk.
584.00
Reinforced cement concrete works using steel shutter with minimum cement
content relates to mix ratio 1:2:4 having minimum f 'cr = 27 Mpa, and satisfying a
specified compressive strength f 'c = 22 Mpa at 28 days on standard cylinders as
per standard practice of Code ACI/BNBC/ASTM & Cement conforming to BDS EN197-1- CEM1, 52.5N (52.5MPa) / ASTM-C 150 Type I, best quality Sylhet sand or
coarse sand of equivalent F.M. 2.2 and 20 mm down well graded stone chips
conforming to ASTM C-33, making, placing shutter in position and maintaining true
to plumb, making shutter water-tight properly, placing reinforcement in position;
mixing in standard mixer machine with hoper fed by standard measuring boxes,
casting in forms, compacting by vibrator machine and curing at least for 28 days,
removing centering-shuttering after specified time approved; including cost of water,
electricity, additional testing charges of materials and cylinders required by
engineer, other charges etc. all complete approved and accepted by the Engineer.
(Rate is excluding the cost of reinforcement and its fabrication, placing and
binding etc)
07.4.1
07.4.1.1
Concrete
cum
Tk.
10,203.00
07.4.1.2
sqm.
Tk.
382.00
07.4.2
07.4.2.1
Concrete
cum
Tk.
10,203.00
07.4.2.2
sqm.
Tk.
391.00
07.4.3
Foundation beam
07.4.3.1
Concrete
cum
Tk.
10,203.00
07.4.3.2
sqm.
Tk.
323.00
07.4.4
Padestals, column, column capitals, lift walla and walls upto Ground Floor
07.4.4.1
Concrete
cum
Tk.
10,304.00
Item No.
88
Description of Item
07.4.4.2
07.4.5
07.4.5.1
Unit
Unit Rate
sqm.
Tk.
373.00
Concrete
cum
Tk.
10,607.00
07.4.5.2
sqm.
Tk.
380.00
07.4.6
Tee beams, Ell beams and Rectangular beams etc upto Ground Floor
07.4.6.1
Concrete
cum
Tk.
10,203.00
07.4.6.2
sqm.
Tk.
415.00
07.4.7
07.4.7.1
Concrete
cum
Tk.
10,203.00
07.4.7.2
sqm.
Tk.
498.00
07.4.8
07.4.8.1
Concrete
cum
Tk.
10,472.00
07.4.8.2
sqm.
Tk.
344.00
07.4.9
07.4.9.1
Concrete
cum
Tk.
10,472.00
07.4.9.2
sqm.
Tk.
410.00
07.4.10
07.4.10.1
Concrete
cum
Tk.
10,472.00
07.4.10.2
sqm.
Tk.
403.00
07.4.11
07.4.11.1
Concrete
cum
Tk.
10,472.00
07.4.11.2
sqm.
Tk.
584.00
Item No.
89
Description of Item
Unit
Unit Rate
07.5.1
07.5.1.1
Concrete
cum
Tk.
7,982.00
07.5.1.2
sqm.
Tk.
354.00
07.5.2
07.5.2.1
Concrete
cum
Tk.
7,982.00
07.5.2.2
sqm.
Tk.
413.00
07.5.3
In foundation beam
07.5.3.1
Concrete
cum
Tk.
7,982.00
07.5.3.2
sqm.
Tk.
355.00
07.5.4
Padestals, column capitals, lift walls and walls upto Ground Floor
07.5.4.1
Concrete
cum
Tk.
8,082.00
07.5.4.2
sqm.
Tk.
412.00
07.5.5
07.5.5.1
Concrete
cum
Tk.
8,384.00
07.5.5.2
sqm.
Tk.
394.00
07.5.6
Tee beams, Ell beams and Rectangular beams etc upto Ground Floor
07.5.6.1
Concrete
cum
Tk.
7,982.00
Item No.
90
Description of Item
07.5.6.2
07.5.7
07.5.7.1
Unit
Unit Rate
cum
Tk.
485.00
Concrete
cum
Tk.
7,982.00
07.5.7.2
sqm.
Tk.
459.00
07.5.8
Cornice, railing, drop walls, louver, fins etc upto Ground Floor
07.5.8.1
Concrete
cum
Tk.
8,250.00
07.5.8.2
sqm.
Tk.
344.00
07.5.9
07.5.9.1
Concrete
cum
Tk.
8,250.00
07.5.9.2
sqm.
Tk.
395.00
07.5.10
07.5.10.1
Concrete
cum
Tk.
8,250.00
07.5.10.2
sqm.
Tk.
381.00
07.5.11
07.5.11.1
Concrete
cum
Tk.
8,250.00
sqm.
Tk.
584.00
07.5.11.2
07.6
Reinforced cement concrete works using steel shutter with minimum cement
content relates to mix ratio 1:1.5:3 having minimum f'cr = 30 Mpa, and satisfying a
specified compressive strength fc = 25 Mpa at 28 days on standard cylinders as per
standard practice of Code ACI/BNBC/ASTM & Cement conforming to BDS EN-1971- CEM1, 52.5N (52.5MPa) / ASTM-C 150 Type I, best quality Sylhet sand or
coarse sand of equivalent F.M. 2.2 and 20 mm down well graded stone chips
conforming to ASTM C-33, making, placing shutter in position and maintaining true
to plumb, making shutter water-tight properly, placing reinforcement in position;
mixing with standard mixer machine with hopper, fed by standard measuring boxes,
casting in forms, compacting by vibrator machine and curing at least for 28 days,
removing centering-shuttering after specified time approved; including cost of water,
electricity, additional testing charges of materials and cylinders required by
engineer, other charges etc. all complete approved and accepted by the Engineer.
(Rate is excluding the cost of reinforcement and its fabrication, placing and
binding etc)
Item No.
91
Description of Item
Unit
Unit Rate
07.6.1
07.6.1.1
Concrete
cum
Tk.
10,526.00
07.6.1.2
sqm.
Tk.
382.00
07.6.2
07.6.2.1
Concrete
cum
Tk.
10,526.00
07.6.2.2
sqm.
Tk.
391.00
07.6.3
Foundation beam
07.6.3.1
Concrete
cum
Tk.
10,526.00
07.6.3.2
sqm.
Tk.
323.00
07.6.4
Padestals, column, column capitals, lift walla and walls upto Ground Floor
07.6.4.1
Concrete
cum
Tk.
10,626.00
07.6.4.2
sqm.
Tk.
373.00
07.6.5
07.6.5.1
Concrete
cum
Tk.
10,929.00
07.6.5.2
sqm.
Tk.
380.00
07.6.6
Tee beams, Ell beams and Rectangular beams etc upto Ground Floor
07.6.6.1
Concrete
cum
Tk.
10,526.00
07.6.6.2
sqm.
Tk.
415.00
07.6.7
07.6.7.1
Concrete
cum
Tk.
10,526.00
07.6.7.2
sqm.
Tk.
498.00
07.6.8
07.6.8.1
Concrete
cum
Tk.
10,794.00
07.6.8.2
sqm.
Tk.
344.00
07.6.9
07.6.9.1
Concrete
cum
Tk.
10,794.00
07.6.9.2
sqm.
Tk.
410.00
07.6.10
07.6.10.1
Concrete
cum
Tk.
10,794.00
07.6.10.2
sqm.
Tk.
403.00
Item No.
92
Description of Item
Unit
Unit Rate
07.6.11
07.6.11.1
Concrete
cum
Tk.
10,794.00
07.6.11.2
sqm.
Tk.
584.00
07.7.1
07.7.1.1
Concrete
cum
Tk.
10,526.00
07.7.1.2
sqm.
Tk.
354.00
07.7.2
07.7.2.1
Concrete
cum
Tk.
10,526.00
07.7.2.2
sqm.
Tk.
413.00
07.7.3
In foundation beam
07.7.3.1
Concrete
cum
Tk.
10,526.00
07.7.3.2
sqm.
Tk.
355.00
07.7.4
Padestals, column capitals, lift walls and walls upto Ground Floor
07.7.4.1
Concrete
cum
Tk.
10,626.00
07.7.4.2
sqm.
Tk.
412.00
Item No.
93
Description of Item
Unit
Unit Rate
07.7.5
07.7.5.1
Concrete
cum
Tk.
10,929.00
07.7.5.2
sqm.
Tk.
394.00
07.7.6
Tee beams, Ell beams and Rectangular beams etc upto Ground Floor
07.7.6.1
Concrete
cum
Tk.
10,526.00
07.7.6.2
sqm.
Tk.
485.00
07.7.7
07.7.7.1
Concrete
cum
Tk.
10,526.00
07.7.7.2
sqm.
Tk.
459.00
07.7.8
Cornice, railing, drop walls, louver, fins etc upto Ground Floor
07.7.8.1
Concrete
cum
Tk.
10,794.00
07.7.8.2
sqm.
Tk.
344.00
07.7.9
07.7.9.1
Concrete
cum
Tk.
10,794.00
07.7.9.2
sqm.
Tk.
395.00
07.7.10
07.7.10.1
Concrete
cum
Tk.
10,794.00
07.7.10.2
sqm.
Tk.
381.00
07.7.11
07.7.11.1
Concrete
cum
Tk.
10,794.00
07.7.11.2
sqm.
Tk.
584.00
Item No.
94
Description of Item
Unit
Unit Rate
Reinforced cement concrete works using steel shutter with minimum cement
content relates to mix ratio 1:1.25:2.5 having minimum f'cr = 40 Mpa, and
satisfying a specified compressive strength fc = 32 Mpa at 28 days on standard
cylinders as per standard practice of Code ACI/BNBC/ASTM & Cement conforming
to BDS EN-197-1- CEM1, 52.5N (52.5MPa)/ ASTM-C 150 Type I, and adding
approved high range water reducing admixture of complying specific type
(generally be Type-G) under ASTM-C 494, best quality coarse sand [Sylhet sand
or coarse sand of equivalent F.M. 2.2], 20 mm down well graded crushed stone chips
conforming to ASTM C-33, including breaking chips and screening through proper
sieves, making and placing shutter in position and maintaining true to plumb,
making shutter water-tight properly, placing reinforcement in position; mixing with
standard mixer machine with hoper and fed by standard measuring boxes, casting in
forms, compacting by vibrator machine and curing at least for 28 days, removing
centering-shuttering after specified time approved; including cost of water,
electricity, additional testing charges of materials and cylinders required by
engineer, other charges etc. all complete approved and accepted by the Engineer.
(Doses of admixture in the mix to be fixed by mix design) (Rate is excluding the
cost of reinforcement and its fabrication, placing and binding etc and admixture)
07.8.1
07.8.1.1
Concrete
cum
Tk.
10,970.00
07.8.1.2
sqm.
Tk.
382.00
07.8.2
07.8.2.1
Concrete
cum
Tk.
10,970.00
07.8.2.2
sqm.
Tk.
391.00
07.8.3
Foundation beam
07.8.3.1
Concrete
cum
Tk.
10,970.00
07.8.3.2
sqm.
Tk.
323.00
07.8.4
Padestals, column, column capitals, lift walla and walls upto Ground Floor
07.8.4.1
Concrete
cum
Tk.
11,071.00
07.8.4.2
sqm.
Tk.
373.00
07.8.5
07.8.5.1
Concrete
cum
Tk.
10,970.00
07.8.5.2
sqm.
Tk.
415.00
07.8.6
Tee beams, Ell beams and Rectangular beams etc upto Ground Floor
07.8.6.1
Concrete
cum
Tk.
10,970.00
07.8.6.2
sqm.
Tk.
498.00
Item No.
95
Description of Item
Unit
Unit Rate
07.8.7
07.8.7.1
Concrete
cum
Tk.
11,239.00
07.8.7.2
sqm.
Tk.
403.00
07.8.8
07.8.8.1
Concrete
cum
Tk.
11,239.00
07.8.8.2
sqm.
Tk.
584.00
07.9
cum
Tk.
190.00
07.10
Concrete
sqm.
Tk.
21.00
07.11
sqm.
Tk.
19.00
07.12
cum
Tk.
194.00
07.13
Concrete
sqm.
Tk.
49.00
07.14
sqm.
Tk.
41.00
07.15
cum
Tk.
194.00
07.16
Concrete
sqm.
Tk.
29.00
07.17
07.17.1
cum
Tk.
82.00
07.17.2
Add for each addl. floor from 6th floor to 9th floor
cum
Tk.
109.00
07.17.3
Add for each addl. floor for 10th floor & above
cum
Tk.
136.00
07.18
Extra rate for RCC work in additional floor: Formwork / shuttering including
curing
07.18.1
sqm.
Tk.
31.00
07.18.2
Add for each addl. floor from 6th floor to 9th floor
sqm.
Tk.
46.00
07.18.3
Add for each addl. floor for 10th floor & above
sqm.
Tk.
62.00
07.19
Extra cost for making as-cast surface of the concrete approved and accepted by
the Engineer. (formwork cost)
sqm.
Tk.
308.00
Item No.
07.20
96
Description of Item
Unit
Unit Rate
Supplying, best quality pliable, cold applied pre-formed self adhesive rubberized/
bituminous water proofing membrane of approved brand / origin / manufacturer from
an authorized local agent or manufacturer having minimum thickness 1.5 mm, lined
with 2 ply cross laminated high density polyethylene film performances and
properties all conforming to ASTM standards and laying, placing, fixing on made up
firm and dry surfaces free from hollows, sharp protrusions, contaminates etc. laid
over-lap by at least 75 mm along the edges and 125 mm at ends ensuring good
initial bond with the surfaces all complete under the strict accordance with the
manufacturer recommendations and instructions providing all safety provisions in all
respects and accepted by the Engineer. (supplied by only manufacturer's authorised
dealer with certificate of origin ) under following specification:
Backing(HDPE) thickness minimum 0.10mm
Membrane thickness
minimum 1.40mm
Total thickness
minimum 1.50mm
Cold flexibility greater than (-) 200C : ASTM D146
07.20.1
liter
Tk.
189.00
07.20.2
liter
Tk.
195.00
07.20.3
liter
Tk.
200.00
07.20.4
liter
Tk.
183.00
07.20.5
liter
Tk.
207.00
07.20.6
liter
Tk.
225.00
Item No.
97
Description of Item
Unit
Unit Rate
07.20.7
Supply and use of water-reducing high range and retarding chemical admixture
in concrete, complying ASTM C-494 Type - G of approved brand/origin/manufacturer
and supplied by only manufacturer's authorised dealer with certificate of
origin :The admixture required to produce concrete of consistency by 12% or
greater (flowing concrete) and for higher strength of concrete and intend to retard
setting time of concrete.
liter
Tk.
171.00
07.21
Supplying, best quality pliable, cold applied pre-formed self adhesive rubberized/
bituminous water proofing membrane of approved brand / origin / manufacturer from
an authorized local agent or manufacturer having minimum thickness 1.5 mm, lined
with 2 ply cross laminated high density polyethylene film performances and
properties all conforming to ASTM standards and laying, placing, fixing on made up
firm and dry surfaces free from hollows, sharp protrusions, contaminates etc. laid
over-lap by at least 75 mm along the edges and 125 mm at ends ensuring good
initial bond with the surfaces all complete under the strict accordance with the
manufacturer recommendations and instructions providing all safety provisions in all
respects and accepted by the Engineer. (supplied by only manufacturer's authorised
dealer with certificate of origin ) under following specification:
Backing(HDPE) thickness minimum 0.10mm
Membrane thickness
minimum 1.40mm
Total thickness
minimum 1.50mm
Cold flexibility greater than (-)200C : ASTM D146
Pliability: "No crack" tested in ASTM D146
Tensile Strength(film only) min 3.50MPa( 35000kN/m2) testing in ASTM D882
Tensile strength (composite) at least 2.40MPa or N/mm2
Elongation (composite) min 300%
Cycling Over Crack at (-) 320C No effect 100cycles ASTM C836-89a
Puncture Resistance greater than 240N ASTM E 154-88
Resistance to Hydrostatic Head at least 50m ASTM D5385
Tear Resistance min 4.0Mpa (N/mm2)
Adhesion to Primed Concrete min 4.0N/mm : ASTM D1000
Water Vapor Transmission Less than 0.10g/m2 per hour : ASTM E96
Water absorption in 24 hour Less than 0.33% ASTM D570
Heat Stability (+) 900C Environmental Complience to conform : ASTM D543
07.21.1
sqm.
Tk.
956.00
07.21.2
sqm.
Tk.
855.00
07.21.3
sqm.
Tk.
891.00
Item No.
07.22
98
Description of Item
Unit
20 mm thick water-proofing work in masonry or on concrete surface with sandcement mortar mixed with specified admixture (supplied from authorized local
agent or from manufacturer comply with ASTM/BS/IS requirements, confirming
current compliance of the admixture to specification requirements like physical
properties, uniformity and equivalence in composition, performance requirements,
delivered in sealed containers having and confirming plainly marked the proprietary
name of the admixture type under this specification, net weight and or volume,
manufacturing and expiry date, shelve life, non aggressiveness to environment and
metals in concrete etc.) under the strict accordance with manufacturer
recommendations / instructions and providing safety provisions in all respect etc. on
sound, firm surfaces all complete including cleaning the surface from dust, loose
particles, remains of oil, grease etc. all complete approved and accepted by the
Engineer. (Cement: CEM-II/A-M)
sqm.
Unit Rate
Tk.
508.00
Item No.
99
Description of Item
Unit
Unit Rate
Unit
Unit Rate
Description of Item
08.1
Supplying, fabrication, and fixing to details as per design : Ribbed or deformed bar
reinforcement for Reinforced Cement Concrete, produced and marked in
accordance with BDS ISO 6935 - 2: 2006 (or standard subsequently released
from BSTI) including straightening and cleaning rust, if any, bending and binding in
position with supply of G.I. wires, splices or laps what so ever etc. complete in all
respects and accepted by the Engineer ( Measurement shall be recorded only on
Standard Mass per Unit length of Bars, while, dia of bars exceeds its standard)
08.1.1
Grade 300 ( RB 300 : complying BDS ISO 6935-2:2006) ribbed or deformed bar
produced and marked according to Bangladesh Standard with minimum yield
strength, fy (ReH)= 300MPa,but fy not exceeding 314MPa and what ever is the
yield strength within allowable limit as per BNBC sec 8.3.3.5 / ACI 318-11 sec
21.1.5.2, the ratio of ultimate tensile strength fu to yield strength fy, shall be at
least 1.25 and minimum elongation after fracture and minimum total elongation at
maximum force is 17% and 8% respectively : up to ground floor
08.1.2
Grade 400 (RB 400 / 400W: complying BDS ISO 6935-2:2006) ribbed or deformed
bar produced and marked according to Bangladesh Standard, with minimum yield
strength, fy (ReH)= 400 Mpa but fy not exceeding 418MPa and what ever is the
yield strength within allowable limit as per BNBC sec 8.3.3.5 /ACI 318-11 sec
21.1.5.2, the ratio ultimate tensile strength fu to yield strength fy, shall be at
least 1.25 and minimum elongation after fracture and minimum total elongation at
maximum force is 16% and 8% respectively : up to ground floor
08.2
Extra rate for M.S. Fabrication work in additional floor shall be incorporated in the
estimate
08.2.1
Per kg
Tk.
81.91
Per kg
Tk.
85.00
Per kg
Tk.
0.39
08.2.2
Add for each addl. floor from 6th floor to 9th floor
Per kg
Tk.
0.77
08.2.3
Add for each addl. floor for 10th floor and above
Per kg
Tk.
1.15
08.3
Mild steel Grade 250 with minimum fy = 250 MPa work in roof truss: supplying and
fabrication of mild steel sections as per design. Hoisting, fitting and fixing in position
with bolts and nuts or rivets or welded and providing two coats of anti-corrosive paint
over a prime coat of red oxide paint etc. complete and accepted by the
Engineer.(Measurement to be given for Truss member only).
Per kg
Tk.
125.00
08.4
Supplying fan hook 300-grade ( RB300) of 16 mm diameter M.S. rod (one meter
straight length) having rounded hook at the middle of bar in proper size so as to be
concealed within fan cup including fabrication and fitting fixing in all floor accepted by
the Engineer.
each
Tk.
103.00
08.5
Item No.
100
Description of Item
Unit
Unit Rate
08.5.1
rm.
Tk.
1,745.00
08.5.2
rm.
Tk.
1,461.00
08.5.3
rm.
Tk.
2,399.00
08.6
Supplying, fitting and fixing PVC water stopper at RCC construction joint in
basements providing 1.5" x 2.5" wooden batten at the top and bottom of water
stopper, binding in place with GI wires etc.
rm.
Tk.
850.00
08.7
Supplying, fitting and fixing 10" wide 16 SWG Aluminium Sheet water stopper in
construction joint of RCC vertical.
rm.
Tk.
286.00
08.8
Providing bearing joints fixed or free with 250 x 375 x 10 mm M.S. (Grade - A36)
shoe plate fitted in the truss angles with 16 mm diameter M.S. rod counter sunk
rivets, welded and anchored to 250 x 375 x 10 mm .M.S shoe plate by two Nos. 19
mm dia M.S. U rod embedded in the bed of the lintel around the reinforcement,
cleaning and greasing the joints for all floors etc. all complete and accepted by the
Engineer.
each
Tk.
3,146.00
Item No.
101
Description of Item
Unit
Unit Rate
Unit
Unit Rate
Description of Item
09.1
Boring/drilling for cast in situ pile up to the required depth and diameter with
minimum 6 m long temporary steel casing, true to vertical, providing bentonite slurry
and maintaining water level in the hole, washing the hole for at least 30 minutes,
clean the bore-hole and make the bore- hole ready for placing steel cage and
concreting including hire charge of rig set with winch machine, tripod stand, trimie
pipe, cost of fuel, lubricant, mobilization, demobilization, maintenance, spares, standbyes, insurance coverage, water, electricity and other charges all compete approved
and accepted by the Engineer. Before commencing boring operation Contractor shall
submit the method statement of cast-in-situ pile work including sequence of boring
and casting, disposal of spoils, test result of materials to the Engineer for approval.
However, Engineers approval shall not relieve the Contractor of his responsibilities
and obligations under contract.
09.1.1
400 mm dia
09.1.1.1
Depth up to 20 m
rm
Tk.
536.00
09.1.1.2
rm
Tk.
4.00
09.1.2
450 mm dia
09.1.2.1
Depth up to 20 m
rm
Tk.
680.00
09.1.2.2
rm
Tk.
5.00
09.1.3
500 mm dia
09.1.3.1
Depth up to 20 m
rm
Tk.
839.00
09.1.3.2
rm
Tk.
7.00
09.1.4
550 mm dia
09.1.4.1
Depth up to 20 m
rm
Tk.
1,014.00
09.1.4.2
rm
Tk.
8.00
09.1.5
600 mm
09.1.5.1
Depth up to 20 m
rm
Tk.
1,209.00
09.1.5.2
rm
Tk.
9.00
Item No.
102
Description of Item
Unit
Unit Rate
09.2
Removing of spoils / mud accumulated during boring for cast in situ pile by wash
boring from working site to a safe distance by contractors own arrangement i.e. with
container set in truck or on cart including loading, unloading everything complete as
per standard practice. (Quantity should be given three times of solid volume of
boring)
cum
Tk.
378.00
09.3
Cast in situ pile with reinforced cement concrete works of high slump by adding high
range water reducing admixture (ASTM C494 Type A or F complying item 7.20.1 or
7.20.6) with minimum cement content relates to mix ratio 1 : 1.5 : 3 having minimum
f'cr = 26 Mpa, and satisfying a specified compressive strength fc = 21 Mpa at 28
days on standard cylinders as per standard practice of Code ACI/BNBC/ASTM &
cement conforming to BDS EN-197-1- CEM1, 52.5N (52.5MPa) / ASTM-C 150 Type
I, best quality coarse sand [Sylhet sand or coarse sand of equivalent F.M.2.2], 20
mm down well graded crushed stone chips conforming to ASTM C-33, including
breaking chips, screening through proper sieves, making, placing re-bar cage in
position, placing and removing tri-pod as per requirement, pouring the concrete in
bore-hole with the help of a trimie pipe, maintaining the trimie pipe immersed in
concrete by at least 1 meter throughout the period of concreting, maintaining
required slump, etc. mixing the aggregates with standard mixer machine with hoper,
casting in forms, all complete including water, electricity, testing of materials and
concrete etc and other charges as per design, drawing etc all complete approved
and accepted by the Engineer. (Rate is excluding the cost of reinforcement and its
fabrication, binding, welding , placing and admixture ( approx doses 150 to 250ltr per
bag of cement which to fix by mix design) )
cum
Tk.
11,578.00
09.4
Providing and making point welding at contact point of the spiral binders at
reasonable intervals with the main reinforcements by electric arc welding for
construction of cast in situ bored pile carefully with highly oxidized electrodes making
the points prominent and accepted by the Engineer (rate is inclusive of all materials
labour, tools and plants, electricity and all equipment).
point
3.9
09.5
Providing and making welded splice over two sides of contact by welding of
minimum 300 mm length at the lap of main reinforcement in re-bar cage to be placed
in bore-hole where necessary by electric arc welding with highly oxidized electrodes
making the joint prominent and accepted by the Engineer. (rate is inclusive of all
materials labour, tools and plants, electricity and all equipment).
rm of
weld
Tk.
472.83
09.6
Labour for breaking head of hardened cast in situ bored pile/pre-cast pile up to
a required length by any means but without damaging the rest and removing the
dismantled materials such as concrete to a safe distance including scraps and
cleaning concrete from steel/M.S. rods, straightening and bending of pile bars,
preparation and making platform where necessary, carrying, all sorts of handling,
stacking the same properly after clearing, leveling and dressing the situ and clearing
the bed etc. complete in all respects and accepted by the Engineer.
(Measurement will be given for the actual pile head volume to be broken)
cum
Tk.
3,603.00
Item No.
09.7
103
Description of Item
Unit
Unit Rate
Conducting static load test as per ASTM D1143 or equivalent standard for the castin-situ/pre-cast pile providing required scaffolding, bracing, jacks, pressure test
gauge, loading unloading, Kentledge and other plants and equipment including
staging, mobilization, demobilization, hire charge, gunny bags, sand and filling
sacs/gunny bags for loading, record readings and preparation of results in standard
forms and other incidental charges per standard practice and procedures including
submission of load test report, furnishing all graph and chart etc. complete in all
respects approved and accepted by the Engineer (Minimum two cyclic loading; one
at service load and another cycle at double the load of service load then to continue
loading till failure of the pile). Before commencing load test, Contractor shall submit
method statement for conducting load test to the Engineer for approval. However,
Engineers approval shall not relieve the Contractor of his responsibilities and
obligations under Contract.
Load Test and Report shall be conducted under the supervission of a professional
Geotechnical Engineer registered in BPERB or Geotechnical Firm registerd in PWD.
Boring and Pouring logs / Driving logs of Piles and Method statement shall be the
part of load test report. (Rates on Load test under the supervision of Experts in the
laboratory of unversities and HBRI can be found in Chapter-32)
09.7.1
Per test
Tk.
53,423.00
09.7.2
Per test
Tk.
100,856.00
09.7.3
Per test
Tk.
138,368.00
09.7.4
Per test
Tk.
198,458.00
09.7.5
Per test
Tk.
245,302.00
09.7.6
Per test
Tk.
293,566.00
09.8
09.8.1
For intermediate loading from 25 tonne to 75 tonne for each additional tonne
Per
tonne
Tk.
1,050.83
09.8.2
For intermediate loading from 75 tonne to 125 tonne for each additional tonne.
Per
tonne
Tk.
1,050.83
09.8.3
For intermediate loading from 125 tonne to 175 tonne for each additional tonne.
Per
tonne
Tk.
1,050.83
09.8.4
For intermediate loading from 175 tonne to 225 tonne for each additional tonne.
Per
tonne
Tk.
1,050.83
09.8.5
For intermediate loading from 225 tonne to 275 tonne for each additional tonne.
Per
tonne
Tk.
1,050.83
Item No.
104
Description of Item
Unit
Unit Rate
09.9
Pre-cast pile made in reinforced cement concrete with minimum cement content
relates to mix ratio 1:1.5:3 having minimum f'cr = 30 Mpa, and satisfying specified
compressive strength fc = 25 Mpa at 28 days on standard cylinders as per standard
practice of Code ACI/BNBC/ASTM & cement conforming to BDS EN-197-1- CEM1,
52.5N (52.5MPa) / ASTM-C 150 Type I, best quality coarse sand (F.M.2.2), 20 mm
down well graded stone chips conforming to ASTM C-33, mixing in standard mixture
machine and fed by standard measuring boxes, including all related works like cost
of breaking chips, screening through proper sieves, cleaning and washing, centering
and shuttering with M.S sheet, M.S angle, F.I bar, nuts and bolts, champering edges
if so, preparation of casting beds, laying polythene there in, placing reinforcement
cages in position, casting, compacting by vibrators and tapered rods as where
necessary, curing for 28 days etc. cost of water, electricity and other charges,
providing fitting fixing pile shoe in position as per design and drawing, tools, plants &
equipments, mobilization, demobilization, hire charge of driving set, labour, test of
materials and concrete etc. all complete as per design, drawing and accepted by the
Engineer. (Rate is excluding the cost of reinforcement and its fabrication, binding,
welding and placing)
09.9.1
rm
Tk.
850.00
09.9.2
rm
Tk.
1,176.00
09.9.3
rm
Tk.
1,520.00
09.9.4
each
Tk.
2,559.00
09.10
Mobilization and demobilization of drop hammer type pre-cast pile driving rig.
Per set
per site
Tk.
3,417.00
09.11
Driving 250 mm x 250 mm size pre-cast pile with drop hammer type rig, and
maintaining Driving Log in prescibed format Before commencing driving
operation, Contractor shall submit method statement for carrying the driving
operation including sequence of driving to the Engineer for approval. However,
Engineers approval shall not relieve the Contractor of his responsibilities and
obligations under contract.
09.11.1
Up to 6 m
rm
Tk.
322.00
09.11.2
From above 6 m to 12 m
rm
Tk.
354.00
09.11.3
From above 12 m to 15 m
rm
Tk.
389.00
09.12
Driving 300 mm x 300 mm size pre-cast pile with drop hammer type rig and
maintaining Driving Log in prescibed format. Before commencing driving
operation, Contractor shall submit method statement for carrying the driving
operation including sequence of driving to the Engineer for approval. However,
Engineers approval shall not relieve the Contractor of his responsibilities and
obligations under contract.
09.12.1
Up to 6 m
rm
Tk.
483.00
09.12.2
From above 6 m to 12 m
rm
Tk.
531.00
09.12.3
From above 12 m to 15 m
rm
Tk.
584.00
Item No.
105
Description of Item
Unit
Unit Rate
09.13
Driving 360 mm x 360 mm size pre-cast pile with drop hammer type rig and
maintaining Driving Log in prescibed format. Before commencing driving
operation, Contractor shall submit method statement for carrying the driving
operation including sequence of driving to the Engineer for approval. However,
Engineers approval shall not relieve the Contractor of his responsibilities and
obligations under contract.
09.13.1
Up to 6 m
rm
Tk.
623.00
09.13.2
From above 6 m to 12 m
rm
Tk.
685.00
09.13.3
From above 12 m to 15 m
rm
Tk.
754.00
09.13.4
From above 15 m to 18 m
rm
Tk.
898.00
09.14
Per set
per site
Tk.
177,757.00
09.15
Driving 250 mm x 250 mm size pre-cast pile by rig fitted with automatic diesel
operated hammer and maintaining Driving Log in prescibed format. Before
commencing driving operation by rig fitted with automatic diesel operated hammer,
Contractor shall submit method statement for carrying the operation including
sequence of driving to the Engineer for approval. However, Engineers approval shall
not relieve the Contractor of his responsibilities and obligations under contract.
rm
Tk.
597.00
09.16
Driving 300 mm x 300 mm size pre-cast pile by rig fitted with automatic diesel
operated hammer and maintaining Driving Log in prescibed format. Before
commencing driving operation by rig fitted with automatic diesel operated hammer,
Contractor shall submit method statement for carrying the operation including
sequence of driving to the Engineer for approval. However, Engineers approval shall
not relieve the Contractor of his responsibilities and obligations under contract.
rm
Tk.
818.00
09.17
Driving 360 mm x 360 mm size pre-cast pile by rig fitted with automatic diesel
operated hammer and maintaining Driving Log in prescibed format. Before
commencing driving operation by rig fitted with automatic diesel operated hammer,
Contractor shall submit method statement for carrying the operation including
sequence of driving to the Engineer for approval. However, Engineers approval shall
not relieve the Contractor of his responsibilities and obligations under contract.
rm
Tk.
895.00
09.18
Pre-cast driven micro-pile with reinforced cement concrete works with minimum
cement content relates to mix ratio 1:1.25:2.5 having minimum f'cr = 35 Mpa, and
satisfying a specified compressive strength fc = 30 Mpa at 28 days on standard
cylinders as per standard practice of Code ACI/BNBC/ASTM & cement conforming to
BDS EN-197-1- CEM1,52.5N (52.5MPa) / ASTM-C 150 Type I, best quality coarse
sand (F.M.2.5) and 20 mm down well-graded stone chips conforming to ASTM C-33,
mixing in standard mixture machine with hoper and fed by standard measuring
boxes, including cost of breaking chips, screening through proper sieves, cleaning
and washing, centering and shuttering with M.S sheet, M.S angle, F.I bar, nuts and
bolts, preparation of bed, laying polythene, placing of reinforcement cage, casting,
compacting by vibrators and tapered rods, curing for 28 days etc. including cost of
water, electricity and other charges, providing pile shoe as per design and drawing,
driving the pile up to the design depth as per standard practice or specified method
providing head cushion, all equipments including mobilization, demobilization and
hire charge of driving set, shampering, test of materials and concrete etc. including
carrying all complete approved and accepted by the Engineer. (Rate is excluding the
cost of reinforcement and its fabrication, binding, welding and placing and driving
pile)
Item No.
106
Description of Item
Unit
Unit Rate
09.18.1
180 mm x180 mm x 7.6 m Pile with reinforced cement concrete (1 : 1.25 : 2.5) with
stone chips
rm
Tk.
463.00
09.18.2
205 mm x 205 mm x 7.6 m Pile with reinforced cement concrete (1 : 1.25 : 2.5) with
stone chips
rm
Tk.
576.00
09.18.3
rm
Tk.
170.00
09.18.4
Driving of 205 mm x 205 mm x 7.6 m Pre-cast Pile, and maintaining Driving Log in
prescibed format
rm
Tk.
200.00
09.19
PDA (Pile Driving Analyzer) Test : Conducting High Strain Dynamic Testing of
piles by an expert & licensed usre of the software(s) as per ASTM D4945, providing
all relevant materials ,equipment,experts,labors,mobilization and demobilization,data
acquisition, CAPWAP analysis, preperation of resultsin standard formsetc. complete
in all respects, approved and accepted by the engineer, where, report shall contain
relevant pile log, prevailing soil investigation report at the place, copy of expertise &
licensing.
09.19.1
PDA test upto 200 metric ton as ultiumate pile capacity : only one pile at a site to
test in single run
each
Tk.
162,377.00
09.19.2
PDA test upto 200 metric ton as ultiumate pile capacity : upto two pile at a site to
test in single run
each
Tk.
148,060.00
09.19.3
PDA test upto 200 metric ton as ultiumate pile capacity : upto three pile at a site to
test in single run
each
Tk.
135,426.00
09.19.4
PDA test upto 200 metric ton as ultiumate pile capacity : upto four pile at a site to
test in single run
each
Tk.
124,253.00
09.19.5
PDA test upto 200 metric ton as ultiumate pile capacity : five pile at a site to test in
single run (Each successive rates for more than five test piles at a site in single run
may be asked)
each
Tk.
114,349.00
09.20
PIT (Pile integrity test) : Conducting low strain dynamic testing of pile as per ASTM
D5882-The standard method for low-strain integrity testing of pile by a qualified and
approved PIT expert, preparing pile heads and providing all relevant materials,
equipment, experts, labour, mobilization, demobilization, data acquisition and
analysis, preparation of results in standard forms and compiling final report with
recommendations on the tests etc. complete in all respects approved and accepted
by the Engineer. (Report shall contain driving log / Boring and pouring logs, Graphs
& Statement on "Calliberation Pile" (pile that tested for its capacity and PIT done
eralier on it, at a place of known soil profiles), Soil investigation report. (Caliberation
pile shall be made and tested first).
Method statement for conducting PIT shall be submitted the Engineer for approval,
and shall be the part of PIT report, However, Engineer's approval shall not relieve
the contractor of his responsibilities and obligations under contract.
09.20.1
Mobilization & demobilization within 100km of Dhaka to site and PIT on12(twelve)
Piles or less
upto 1st
12pile
Tk.
24,021.00
09.20.2
Additional charge on Mobilization & demobilization beyond 100km off Dhaka to site
per km
Tk.
30.00
Item No.
107
Description of Item
09.20.3
For PIT test of each additional pile after 12(twelve) pile tested.
09.21
Pre-cast spliced pile jointing by supplying, fitting, fixing prefabricated square shaped
two steel caps made up by 6mm thick ASTM A36 complied M.S plate, sides formed
by bent in channel shape to have only two line of joinery on faces, having min 50 mm
dia hole on its web; capping by min 12 mm thick ASTM A36 complied M.S plate
shaping the edges in 45, having min 40 mm dia hole at centre to pass 25 mm M.S
bar 433 mm in length; jointed at channels root by welding; caps fitted with 2 nos BDS
ISO 6935-2009: B420 DWR complied d20 U-bar 1244mm in length by welding,
equidistance from centre holes of cap and shall have min 75 mm clear from pile
faces; and finally, the system be fitted in correct alignments on pile head positions
waiting for concreting; both the pile heads fitted with the steel caps be welded
together through v-notehes in field, while one of the companion segment of piles
drived in ground and other one placed over it maintaining true verticality; all complete
as per direction and stepwise approval leading to final approval of Engineer in
charge.
09.21.1
Unit
Unit Rate
per pile
Tk.
1,201.00
each
Tk.
13,568
09.21.2
each
Tk.
11,777
09.21.3
each
Tk.
10,159
09.22
09.22.1
Driving pre-cast pile made in square cut ends(tip) without shoe of any size in
the range, 250mmx250mm to 450mmx450mm having pile segment up to 21.0m in
length; by Hydraulic Static Pile driver of approx. 180.00 tonne (metric ton) capacity;
arranged with necessary cranes, power source, maintaining driving log and record of
pressure exerted on piles driven in to desired RL or Capacity level ; complete in all
respect including mobilizing demobilizing of machines & equipment, handling of
piles, dressing & leveling of site, way making, surveying, layout setting etc ended
with the submission of pile driving report in three copies duly signed by professional
engineer and approved by the engineer.
per rm
Tk.
932
09.22.1.1
Making Pre-Cast Piles with Square Cut ends with lengths upto 21.0m in
reinforced cement concrete works having minimum cement content relates to mix
ratio 1:1.5:3, leading minimum f'cr = 30 Mpa, and satisfying specified compressive
strength fc = 25 Mpa at 28 days on standard cylinders as per standard practice of
Code ACI/BNBC/ASTM & cement conforming to BDS EN-197-1- CEM1,52.5N
(52.5MPa) / ASTM-C 150 Type I, best quality coarse sand (F.M.2.2), 20 mm down
well graded stone chips conforming to ASTM C-33, mixing in standard mixture
machine fitted with hopper and fed by standard measuring boxes, including all
related works like cost of breaking chips, screening through proper sieves, cleaning
and washing, centering and shuttering with M.S sheet, M.S angle, F.I bar, nuts and
bolts, champering edges if so, preparation of casting beds, laying polythene there
in, providing reinforcement & placing fitting fixing in position, casting concrete,
compacting by vibrators and tapered rods as where necessary, curing for 28 days
etc. cost of water, electricity and other charges, as per design and drawing, tools,
plants & equipments, mobilization, demobilization, labour, test of materials and
concrete etc. complete in all respect as per design, drawing and accepted by the
Engineer.
per cum
Tk.
22,807.04
Item No.
108
Description of Item
Unit
Unit Rate
Unit
Unit Rate
Description of Item
10.1
Supplying, fitting and fixing 0.457 mm thick corrugated galvanized iron sheet
(Bangladesh made) having min weight 63-65 kg per bundle (2'-6" width 70 72 rft
long) fitted and fixed on M.S. sections with 'J' hook or wooden purlin with screws,
limpet washers and putty etc. all complete and accepted by the Engineer.
10.1.1
sqm
Tk.
585.00
10.1.2
sqm
Tk.
588.00
10.2
Supplying, fitting and fixing 1.5 mm thick fiber glass sheet roofing fitted and fixed
on M.S. sections with 'J' hook or wooden purlin with screws, limpet washers and
putty etc. all complete and accepted by the Engineer.
sqm
Tk.
1,240.00
10.3
0.27 mm thick galvanized iron plain sheet ridging with 300 mm lap on either side
fitted and fixed with galvanized bolts and nuts etc. all complete and accepted by the
Engineer.
10.3.1
Galvanized
rm
Tk.
356.00
10.3.2
Colored
rm
Tk.
397.00
10.4
1.5 mm thick plain fiberglass sheet ridging with 300 mm lap on either side fitted
and fixed with galvanized bolts and nuts etc. all complete and accepted by the
Engineer.
rm
Tk.
618.00
10.5
Saftey Canopy: Supplying temporary safety canopy & around construction work
place where public safety is possibly be endangered due to constructional activities,
which shall be made of aligning truss system of steel sections at 1800 mm c/c as
maximum and making flooring system by corrugated galvanized iron sheets of
approx 0.45mm thick. Placed on steel sections aligned perpendicular to truss at 900
mm c/c as maximum. All fitted. Fixed in position providing necessary anchors,
cables, wires, ties etc. by standard anchoring & welding, nut-bolts etc, all complete
and certified for safe and accepted by the Engineer
sqm
Tk.
1,531.00
Item No.
109
Description of Item
Unit
Unit Rate
Description of Item
Unit
Unit Rate
11.1
Supplying and making door and window frames (Chowkat) for all floors with
matured natural seasoned wood of required size including painting two coats of coal
tar to the surface in contact with wall, fitting and fixing in position etc. complete and
accepted by the Engineer. (All sizes of wood are finished).
11.1.1
cum
Tk.
122,093.00
11.1.2
Mehgoni
cum
Tk.
117,144.00
11.1.3
Silkarai
cum
Tk.
159,093.00
11.1.4
cum
Tk.
173,938.00
11.1.5
Chittagong Teak
cum
Tk.
243,217.00
11.2
Supplying, fitting and fixing M.S. flat bar clamp of 225 x 38 x 6 mm size having
bifurcated ends to door and window frames with necessary screws and encasing
inside the wall with cement concrete (1:2:4) etc. complete and accepted by the
Engineer.
each
Tk.
86.00
11.3
Supplying, fitting and fixing M.S. flat bar clamp 150 x 38 x 6 mm size having
bifurcated ends to door and window frames with rowel plug, necessary screws etc.
including cutting groove in Chowkat if necessary etc. complete in all respect
accepted by the Engineer.
each
Tk.
89.00
11.4
Supplying, fitting and fixing double leaf door frame for all floors with 38 x 38 x 6 mm
M.S. angle fitted with 250 mm long 6 Nos. of iron clamps of same size (with one end
bifurcated) with the vertical members of the frame, fixing the frame in wall with
cement concrete (1:2:4), mending good the damages, fixing 6 Nos. of 100 mm size
iron hinges with the vertical members of the frame all complete including cutting,
sizing, welding, fabricating, carrying from work-shop to site and local carriage, curing
etc. complete as per plan and drawing and accepted by the Engineer.
rm
Tk.
563.00
11.5
Supplying, fitting and fixing of door frame for single leaf in all floors with 38 x 38 x 6
mm M.S. angle, fixing 130 mm long 6 Nos. of iron clamps of same size (with one end
bifurcated) with the vertical members of the frame, fixing the frame in wall with
cement concrete (1:2:4), mending good the damages, fixing 4 Nos. of 100 mm size
iron hinges with the vertical members of the frame all complete including cutting,
sizing, welding, fabricating, carriage from workshop to site including local carriage,
curing etc. as per plan and drawing etc. all complete and accepted by the Engineer.
(Running meter of the doorframe will be considered towards measurement).
rm
Tk.
554.00
11.6
Supplying seasoned wood and making roof truss of any size with wall plates as
per design in/c supplying, fabricating and hoisting, scaffolding, fitting and fixing in
position with bolts, nuts, coal tarring in 2 coats etc. all complete and accepted by the
Engineer.
(All sizes of wood are finished).
11.6.1
cum
Tk.
105,986.00
Item No.
110
Description of Item
Unit
Unit Rate
11.6.2
Mehgoni
cum
Tk.
101,532.00
11.6.3
Silkarai (Chittagong)/Chickrashi
cum
Tk.
141,615.00
11.7
Supplying and making seasoned wooden hand rail of stair case etc. including
necessary molding with proper corner finishing as per design, fitted and fixed in
position in all floors etc. all complete and accepted by the Engineer.
11.7.1
Silkarai / Chickrashi
cum
Tk.
155,849.00
11.7.2
Chittagong Teak
cum
Tk.
231,560.00
11.7.3
Mehgoni
cum
Tk.
115,766.00
11.7.4
Local Sal
cum
Tk.
120,220.00
Item No.
111
Description of Item
Unit
Unit Rate
Unit
Rate
Description of Item
12.1
Supplying, fitting and fixing 38 mm thick well matured, seasoned (min 10" wide
plank) solid wood single leaf door shutter having top rail style of sections 100 mm
x 38 mm, lock rail 125 x 38 mm and bottom rail 225 x 38 mm. Closed joints with 25
mm x 12 mm size wooden peg and provided with best quality 4 Nos. 100 mm iron
hinges 2 (two) Nos. best quality 12 mm dia 300 mm and 200 mm long iron tower and
socket bolts, 2 (two) Nos. heavy type nickel plated handle, hinged cleats, buffer
blocks and finished by sand papering etc. all complete in all floors and accepted by
the Engineer.(All sizes of wood are finished)
12.1.1
Kathal
sqm
Tk.
6,840.00
12.1.2
Gamari
sqm
Tk.
6,242.00
12.1.3
Teak Chambal
sqm
Tk.
8,534.00
12.1.4
Chittagong Teak
sqm
Tk.
11,324.00
12.1.5
Chapalish
sqm
Tk.
6,541.00
12.2
Supplying, fitting and fixing 38 mm thick well matured, natural seasoned (min 10"
wide plank) solid wood single leaf flush door shutter having a frame of top lock
and bottom rail of sections 100 mm x 12 mm styles 100 mm x 38 mm covered with
100 mm x 12 mm plank, screwed to each face and provided with best quality 4 Nos.
100 mm iron hinges, 2 (two) Nos. best quality 12 mm dia 300 mm and 200 mm long
iron tower and socket bolts, 2 (two) Nos. heavy type nickel plated handles, hinged
cleats, buffer blocks and finished by sand papering etc. all complete in all floors and
accepted by the Engineer. (All sizes of wood are finished)
12.2.1
Kathal
sqm
Tk.
5,886.00
12.2.2
Gamari
sqm
Tk.
5,354.00
12.2.3
Teak Chambal
sqm
Tk.
7,393.00
12.2.4
Chittagong Teak
sqm
Tk.
9,875.00
12.2.5
Chapalish
sqm
Tk.
5,620.00
12.3
Supplying, fitting and fixing 38 mm finished well matured, natural seasoned (min 10"
wide plank) wooden ornamental special design (equivalent hatil) both sides single
panel flush door shutter with top and middle rail 150 mm x 38mm bottom rail 225
mm x 38 mm and style 125 mm x 38 mm, having vertical panels 175 mm x 38 mm
in./c minimum 12 mm lap to each panel providing 4 nos, best quality 100 mm brass
hinges, 12 mm dia best quality 200 mm & 300 mm brass socket and tower bolts
2(two) now heavy type best quality brass handle hinges cleats, wooden buffer blocks
in/c supply of necessary nails and screws finished by making design by machine
finished etc. all complete in all floors and accepted by the Engineer (Ctg. teak
wood).
sqm
Tk.
14,344.00
Item No.
112
Description of Item
Unit
Unit Rate
12.4
Supplying, fitting and fixing 38 mm thick well matured, natural seasoned (min 10"
wide plank) wooden double leaf panel door shutters. Top rail and styles of
sections 100 mm x 38 mm, lock rail 125 mm x 38 mm and bottom rail 225mm x 38
mm, paneling 38 mm thick both sides raised, provided with best quality 6 Nos. 100
mm iron hinges, 2 (two) Nos. best quality 12 mm dia 300 mm and 225 mm long iron
tower and socket bolts, 2 (two) Nos. heavy type nickel plated handle, 1 No. hatchbolt hinged cleats, buffer blocks and finished by sand papering, necessary screws
etc. all complete in all floors and accepted by the Engineer. (Double leaf. All sizes of
wood are finished)
12.4.1
Kathal
sqm
Tk.
8,242.00
12.4.2
Gamari
sqm
Tk.
7,496.00
12.4.3
Teak Chambal
sqm
Tk.
10,358.00
12.4.4
Chittagong Teak
sqm
Tk.
13,844.00
12.4.5
Chapalish
sqm
Tk.
7,869.00
12.5
Supplying, fitting and fixing 38 mm thick well matured, natural seasoned (min.10"
wide plank) wooden double leaf panel door shutters. Top rail and styles of
sections 100 mm x 38 mm. lock rail 125 mm x 38 mm and bottom rail 225 mm x 38
mm. paneling 25 mm thick one side raised, provided with best quality 6 nos. 100 mm
iron hinges, 2 (two) Nos. best quality 12 mm dia 300 mm and 200 mm long iron
tower and socket bolts, 2 (two) Nos. heavy type nickel plated handles, 1 No. hatchbolt hinged cleats, buffer blocks and finished by sand papering, necessary screws
etc. all complete in all floors and accepted by the Engineer.(Double leaf. All sizes of
wood are finished)
12.5.1
Kathal
sqm
Tk.
7,172.00
12.5.2
Gamari
sqm
Tk.
6,535.00
12.5.3
Teak Chambal
sqm
Tk.
8,976.00
12.5.4
Chittagong Teak
sqm
Tk.
11,947.00
12.5.5
Chapalish
sqm
Tk.
6,854.00
12.6
Supplying, fitting and fixing 38 mm finished thick well matured, natural seasoned
(min. 10" wide plank) wooden grooved single panel flush door shutters with top
and middle rail 100 mm x 38 mm, bottom rail 225 mm x 38 mm and style 100 mm x
38 mm, having vertical panels 100 x 38 mm including keeping 6 mm x 12 mm even
groove all around and minimum 12 mm grooved lap to each panel. Providing 4 Nos.
best quality 100 mm iron hinges, 12 mm dia best quality 200 mm and 300 mm iron
socket and tower bolts, 2 (two) Nos. heavy type best quality nickel plated handle
hinged cleats, wooden buffer blocks including supply of necessary nails and screws,
finished by sand papering etc. complete in all respect in all floors as per drawing and
as per standard practice and accepted by the Engineer. (All sizes of wood are
finished).
12.6.1
Kathal
sqm
Tk.
7,934.00
12.6.2
Gamari
sqm
Tk.
7,228.00
Item No.
113
Description of Item
Unit
Unit Rate
12.6.3
Chittagong Teak
sqm
Tk.
13,223.00
12.6.4
Chapalish
sqm
Tk.
7,581.00
12.7
Supplying, fitting and fixing 36 mm thick and having density 400 kg/cum solid
particle board single leaf flush door for all floors for internal use made of well
matured mechanical seasoned Rubber (Malaysian timber) or other approved wooden
frame having finished size 35 x 50 mm around upon which 1.2 mm thick veneer (total
two Nos. of veneers one of 0.7 mm horizontally made of gorjon and another of 0.5
mm vertically made of Burma Teak or Champa or Chapalish or Garjan wood) with
necessary screws are pested on each side by mechanized process and provided
with best quality 4 Nos. 100 mm iron hinges, 2 Nos. best quality 12 mm iron dia 300
mm and 225 mm long iron tower and socket bolts, 2 (two) Nos. heavy type nickel
plated handles, hinged cleats, buffer blocks etc. complete and accepted by the
Engineer.
12.7.1
sqm
Tk.
5,061.00
12.7.2
Champ veneered
sqm
Tk.
3,831.00
12.7.3
Chapalish veneered
sqm
Tk.
3,818.00
12.7.4
Garjan veneered
sqm
Tk.
3,519.00
12.8
Manufacturing and supplying, fitting, fixing well matured, natural seasoned (min 10"
wide plank) wooden fixed louver shutters having 62 x 125 mm frame and inner
horizontal wooden louver 150 x 25 mm size spaced @ 50 mm c/c fixed with frame in
grooves including cost of screws, nails, 12 mm x 12 mm size wooden bit, preparing
the surface by sand papering etc. complete in all respect as per drawing and
accepted by the Engineer. (All sizes of wood are finished).
12.8.1
Gamari
sqm
Tk.
9,594.00
12.8.2
Chittagong Teak
sqm
Tk.
20,620.00
12.8.3
Chapalish
sqm
Tk.
10,242.00
12.9
Supplying, fitting and fixing well matured, natural seasoned (min 10 wide plank)
wooden glazed ventilator louver shutters for all floors having wooden outer frame
of section 62 x 125 mm (finished) with 62 x 125 mm (finished) size vertical divider
with inner 50 mm x 38 mm shutter and with 3 Nos. horizontal 38 mm x 38 mm sash
bar in each part and inner horizontal glazed louver of size 150 x 6 mm (local) fixed in
frame @ 154 mm c/c by cutting grooves in the frame including cost of screws,
wooden bit, pivots, sand papering, cutting glass to required size etc. all complete as
per design, drawing and as per standard practice and accepted by the Engineer. (All
sizes of wood are finished).
12.9.1
Gamari
sqm
Tk.
6,491.00
12.9.2
Teak Chambal
sqm
Tk.
9,417.00
12.9.3
Chittagong Teak
sqm
Tk.
12,979.00
12.9.4
Chapalish
sqm
Tk.
6,873.00
Item No.
114
Description of Item
Unit
Unit Rate
12.10
Supplying fitting and fixing 38 mm thick well matured, natural seasoned (min 10"
wide plank) wooden door shutters for all floors having styles and rails of section
150 mm x 38 mm and 5 mm glass panes fitted and fixed with wooden batten, putty
and nails including supplying and fitting and fixing 50 mm dia best quality round door
lock. 12 mm dia, 1200 mm long iron tower bolt and 8 Nos. 100 mm iron hinges to
each shutters, 2 Nos. nickel plated handle, hinged cleats, buffer blocks, screws,
finished with necessary sand papering and putty works etc. complete and accepted
by the Engineer. (All sizes of wood are finished).
12.10.1
Chittagong Teak
sqm
Tk.
8,016.00
12.10.2
Silkarai
sqm
Tk.
6,112.00
12.11
Supplying, fitting and fixing 25 mm thick well matured natural seasoned (min 10
wide plank) Kathal wood door and window shutters for all floors having 75 x 25
mm Z battens, provided with best quality 3 Nos. 100 mm iron hinges, 2 Nos. 62 mm
dia iron ring fitted with nuts, 2 Nos. best quality 12 mm dia, 300 mm and 225 mm
long iron tower and socket bolts, hinged cleats, buffer blocks, screws and finished
with sand papering in all floors etc. complete and accepted by the Engineer. (All
sizes of wood are finished).
sqm
Tk.
5,505.00
12.12
Supplying, fitting and fixing 38 mm thick well matured natural seasoned (min 10"
wide plank) wood glazed window shutters for all floors having horizontal and
vertical sections of 87 x 38 mm and sash bar 38 x 38 mm fitted with 3 mm glass
panes with putty and nails and provided with best quality 4 Nos. 75 mm iron hinges,
2 (two) Nos. best quality 12 mm dia 250 mm and 150 mm long iron tower and socket
bolts, nickel plated handles 225 mm long catch hooks or hinged cleats, buffer blocks,
necessary screws and finished with sand papering for all floors etc. complete and
accepted by the Engineer. (All sizes of wood are finished).
12.12.1
Kathal
sqm
Tk.
5,567.00
12.12.2
Gamari
sqm
Tk.
5,125.00
12.12.3
Teak Chambal
sqm
Tk.
6,820.00
12.12.4
Chittagong Teak
sqm
Tk.
8,882.00
12.12.5
Chapalish
sqm
Tk.
5,346.00
12.13
Supplying, fitting and fixing 38 mm thick well matured, seasoned (min 10" wide
plank) wood window shutter one third glazed and two third raised paneling on
both sides and 38 mm thick for all floors having horizontal and vertical sections of 87
mm x 38 mm and sash bars 38 x 38 mm fitted with 3 mm glass panes with putty and
nails and provided with best quality 4 Nos. 75 mm iron hinges. 2 (two) Nos. best
quality 12 mm dia 250 mm and 150 long iron tower and socket bolts, nickel plated
handles, 225 mm long catch hooks or hinged cleats, buffer blocks and finished by
sand papering for all floors etc. complete and accepted by the Engineer. (All sizes of
wood are finished).
12.13.1
Kathal
sqm
Tk.
8,126.00
12.13.2
Gamari
sqm
Tk.
7,333.00
12.13.3
Teak Chambal
sqm
Tk.
10,374.00
Item No.
115
Description of Item
Unit
Unit Rate
12.13.4
Chittagong Teak
sqm
Tk.
14,077.00
12.13.5
Chapalish
sqm
Tk.
7,729.00
12.14
cum
Tk.
16,203.00
12.15.1
Supplying, fitting and fixing steel glazed window shutter for all floors with frames as
per design having 25 x 25 x 5 mm angle section for Chowkat and shutters and 50 x
25 x 5 mm T- section used for vertical member and 25 x 5 mm F.I. bar for making
box (combining with angle) and 25 x 19 x 5 mm Tee used for glass divider etc.
including all cost of charges for welding, riveting etc. supplying all essential fittings,
like iron hinges, plate handle, pin-stopper, adjustable cleat and clamps, fitting and
fixing the frame including. supplying, fitting, fixing 3 mm glass panes by pucca putty
and making necessary holes in walls and R.C.C works and necessary fitting with
C.C. (1:2:4) and mending good the damages including. all cost of carriage, workshop
charges, electricity, and labour for fittings, fixing, curing etc. all complete and
accepted by the Engineer.
sqm
Tk.
5,572.00
12.15.2
Supplying, fitting and fixing M.S. door shutter made with 1.5 x 1.5 x angle outer
frame, inner member 1 x F.I. bar, cladding with 16 BWG M.S. sheet, hinged with
2 x 2 x M.S. angle Chowkat.
sqm
Tk.
5,828.00
12.16
Supplying, fitting and fixing steel glazed window shutter for all floors with frames as
per design having 19 x 19 x 19 x 3 mm Z-section in frame and 19 x 3 mm F.I. bar for
making T-section for horizontal dividers of shutters and 25 x 3 mm F.I. bar for middle
vertical members of frame including all cost of charges for fabrication and
manufacture by welding riveting etc. supplying all essential fittings like 2 Nos.
stopper, handle, 150 mm long 3 Nos. adjustable cleats, iron pins, hinges, 150 mm
long 4 Nos. clamps, for fitting frame including supplying, fitting, fixing 3 mm glass
panes by pucca putty and making necessary holes in brick and R.C.C. wall or
member as necessary filling with C.C. (1:2:4) and mending good the damages
including all cost of carriage, electricity, workshop charges and labour in fitting, fixing
etc. all complete as per drawing and design and accepted by the Engineer.
12.16.1
With provision for fan-light (total wt of grill without glass panes is min 28.13 kg for
15 sft)
sqm
Tk.
3,549.00
12.16.2
Without provision for fan-light (total wt of grill without glass panes is min 24.84 kg
for 15 sft)
sqm
Tk.
3,304.00
12.17
Manufacturing, supplying fitting and fixing of fixed glazed frame for all floors with
outer member of 19 x 19 x 19 x 3 mm Z-section and vertical and horizontal dividers
of 19 x 19 x 3 mm T-section including all cost of fabrication and welding, supplying
and fixing of 19 x 19 x 3 mm angle clamps of 150 mm length (with one end
bifurcated) of required Nos, with the frame, fixing the frame in wall with (1:2:4)
cement concrete in the hole for clamp after making necessary grooves, supplying
and fixing of 3 mm glass panes with pucca putty, mending good all damages,
painting iron face with two coats of synthetic enamel paint over a coat of anticorrosive priming to approved colour and quality etc. cost of electricity, workshop
charges, carriage etc. all complete as per drawing and accepted by the Engineer.
[Rate is excluding the cost of painting](Scope of work of this item is in staircase and
over partition wall etc.)
sqm
Tk.
3,156.00
Item No.
116
Description of Item
Unit
Unit Rate
12.18
Supplying, fitting and fixing 25 mm thick wooden double leaf fly proof wire mesh
window shutter for all floors with 75 x 25 mm vertical and horizontal style and sash
bar of 38 x 25 mm section provided with 24 B.W.G. G.I wire mesh netting of 20 mesh
fitted and fixed with shutter by 12 x 12 mm wooden bit, brass screws, nails etc.
including supply of all necessary fittings such as 2 Nos. 150 mm long brass tower
and socket bolt of best quality 4 Nos. 75 mm brass hinges, heavy type 2 Nos. 150
mm long catch hook and 100 mm long brass handle 2 Nos. including fitting and fixing
the same in position with frame with supply of necessary screws and nails etc.
complete and accepted by the Engineer. (All sizes of wood are finished)
12.18.1
Kathal
sqm
Tk.
4,740.00
12.18.2
Teak Chambal
sqm
Tk.
5,542.00
12.18.3
Chittagong Teak
sqm
Tk.
6,864.00
12.19
Supplying, fitting and fixing of well matured louver shutter having 75.50mm x 38mm
size all around frame and inner horizontal wooden louver blade 65mm x 20mm
spaced @ 38mm c/c, fixed with frame in grooves including cost of nails, handle,
tower bolt, screws (brass fitting) etc. all complete in all respect as per drawing and
direction of the Engineer in charge.
sqm
Tk.
14,259.00
12.20
Supplying, fitting and fixing 3" X 3/4" Chittagong Teak wood moulding bit as per
design etc. all complete approved and accepted by the Engineer.
rm
Tk.
1,090.00
12.21
Extra cost for using brass/ SS fittings in place of iron fittings in doors & windows
for all floors (super quality local).
12.21.1
sqm
Tk.
479.00
12.21.2
SS fittings of door
sqm
Tk.
292.00
12.21.3
sqm
Tk.
823.00
12.21.4
SS fittings of windows
sqm
Tk.
562.00
12.22
Supplying, fitting and fixing of made in hydraulic door closer (big size) including all
necessary tools and accessories etc. all complete approved and accepted by the
Engineer.
each
Tk.
2,521.00
12.23.1
Supplying, fitting and fixing MORTICE door lock approved and accepted by the
Engineer.
each
Tk.
1,620.00
12.23.2
Supplying, fitting and fixing Rim/ round door lock approved and accepted by the
Engineer.
each
Tk.
962.00
12.24
Supplying, fitting and fixing of best quality magnetic door shock absorber including
all necessary tools and accessories etc. all complete approved and accepted by the
Engineer
each
Tk.
272.00
12.25
Supplying, fitting and fixing best quality heavy type 19 mm dia and to 300 mm long
brass hasp bolt including cutting grooves in door shutter and frames, screws etc. all
complete approved and accepted by the Engineer.
each
Tk.
403.00
Item No.
117
Description of Item
Unit
Unit Rate
13.2
Description of Item
Unit
Supplying, fitting and fixing window grills made of 16 mm dia M.S. rod @ 100 mm
c/c fitted with 3 (three) Nos. horizontal M.S. flat bar (38 x 6 mm) including fabrication,
welding, riveting, cost of electricity, workshop charges, carriage, fixing with preplaced clamps in walls/RCC member for all floors etc. complete and accepted by the
Engineer. (Total weight per sqm should be approx. 22.8 kg and add or deduct @ Tk.
35.00 for each kg excess or less respectively)
sqm
Tk.
2,161.00
sqm
Tk.
1,545.00
sqm
Tk.
1,640.00
Tk.
1,515.00
Tk.
2,262.94
Tk.
2,041.00
Supplying, fitting and fixing window grills of any design made of mild steel section
approx. 20 x 3 mm) with outer frame of approx 25 x 6 mm) F.I. bar fabricating,
welding, cost of electricity, workshop charges, carriage, fixing with pre-placed clamps
in walls or RCC member, all necessary tools and plants etc complete for all floors
and accepted by the Engineer. (Total weight per sqm should be approx 11.0 kg. and
add or deduct @ Tk. 140 for each kg. excess or less respectively)
Unit Rate
13.3
Supplying, fitting and fixing window grills of any design made with approx 20 x 5 mm
F.I. bar as inner and outer section; including fabricating, welding cost of electricity
and tools and plants etc. complete for all floors accepted by the Engineer.
(Total weight per sqm should be min 12 kg. and add or deduct. @ Tk. 136 for each
kg. excess or less respectively)
13.3.1
Supplying, fitting and fixing window grills of any design made with approx 20 x 5 mm
F.I. bar as inner members but no outer frame; including fabricating, welding cost of
electricity and tools and plants etc. complete for all floors accepted by the Engineer.
(Total weight per sqm should be approx 10 kg. and add or deduct. @ Tk. 152 for
each kg. excess or less respectively)
13.4.1
Supplying, fitting, fixing window grills of any design made with approx 25 x 6 mm F.I.
bar as both outer and inner section; including fabrication, welding, cost of electricity
workshop charges, carriage, cutting grooves, mending good the damages, tools and
plants etc. complete for all floors accepted by the Engineer. (Total weight per sqm
should be approx 21 kg. and add or deduct @ Tk. 113 for each kg. excess or less
respectively)
13.4.1.1
Supplying, fitting, fixing window grills of any design made with approx 25 x 6 mm F.I.
bar as inner section but no outer frame; including fabrication, welding, cost of
electricity workshop charges, carriage, cutting grooves, mending good the damages,
tools and plants etc. complete for all floors accepted by the Engineer. (Total weight
per sqm should be approx 18 kg. and add or deduct @ Tk. 108 for each kg. excess
or less respectively)
13.4.2
Supplying, fitting and fixing window grill made of M.S. section approx 25 x 6mm outer
frame and approx 20 x 5mm inner member as per drawing and design approved and
accepted by the Engineer. (Total weight per sqm should be min 14 kg. and add or
deduct @ Tk. 125 for each kg. excess or less respectively)
sqm
Tk.
1,747.85
13.5.1
Supplying, fitting and fixing window grill made of approx12mm x 12mm M.S. solid bar
140mm c/c with outer frame of approx 38 x 6mm F.I. bar as per design approved and
accepted by the Engineer.
sqm
Tk.
2,416.00
13.5.2
Supplying, fitting and fixing window grill made of approx 10mm x 10mm M.S. solid
bar 140mm c/c with outer frame of approx 38 x 6mm F.I. bar as per design approved
and accepted by the Engineer.
sqm
Tk.
2,159.00
sqm
Item No.
118
Description of Item
Unit
13.5.3
Supply, fitting and fixing window grill made of approx 12 x 12mm hollow M.S. box
made of minimum 16 BWG M.S. sheet @ 100mm c/c with outer frame of 38 x 6mm
F.I. bar as per drawing approved and accepted by the Engineer.
sqm
Tk.
13.6
Supplying, fitting and fixing window grills made of mild steel section 25 mm x 3
mm including fabrication, welding, cost of electricity, workshop charges, carriage,
fixing with pre-placed clamps in walls or RCC member, all necessary tools and plants
etc complete for all floors and accepted by the Engineer.
(Total weight per sqm should be min 0.81 kg. and add or deduct @ Tk. 59.00 for
each kg. excess or less respectively)
sqm
Tk.
1,629.00
13.7
Supplying, fitting and fixing veranda grill made of 10 mm dia M.S. rods provided
75 mm c/c in any position both ways as per design with outside frame 25 x 25 x 6
mm M.S. angle including fabricating welding in each point painting 2 coats of
synthetic enamel paint over a coat of anti-corrosive priming including cost of
electricity, tools and plants, workshop charges, carriage of the same including cutting
groves in the R.C.C. or brick work, mending good the damages with C.C. (1:2:4) etc.
complete for all floors accepted by the Engineer. [Rate is excluding the cost of
painting]
(Total weight per sqm should be min 57.68 kg. and add or deduct @ Tk. 35.00 for
each kg. excess or less respectively)
sqm
Tk.
2,080.00
13.8
Supplying, fitting and fixing and fixing verandah grills made of 3/8 dia M.S. rod
placed @ 3 c/c both ways fitted with outer frame of M.S. angle 1 x 1 x as per
drawing and approved and accepted by the Engineer.
sqm
Tk.
2,353.00
Unit Rate
2,206.00
Item No.
119
Description of Item
Unit
Unit Rate
Unit
Unit Rate
Description of Item
Supplying fitting and fixing of Aluminium swing door with spandrel as per the U.S.
Architectural Aluminium Manufacturers Association (AAMA) standard specification
having 1.8 mm thick wall frame size 101.60 mm. 44.45 mm. 83.21 mm). 2.33 mm
thick shutter size (54 mm, 46 mm), 0.99 mm thick door glass bit (size 16.54 mm.
14.49 mm 0.115 kg/m), 2.5 mm thick clousure section (size 101.60 mm, 42.93 mm
1.2 mm), 106.60 mm clousure cover (0.45 kg/m), 4 mm thick floor bottom (size
101.60 mm. 12.70 mm 1 kg/m), 1.8 mm thick shutter bottom (size 82.6 mm, 43.99
mm, 0.60 kg/m), 1.8 mm thick shutter top (size 51 mm, 43.99 mm, 1.88 kg/m) and
2.3 mm to 4.01 mm thick handle (size 101.60 mm, 38.10 mm, 25.40 mm short, 1.35
kg/m) section of all aluminum members will be anodized to aluminium bronze/silver
colour with a coat not less than 15 micrones in thickness and density of 4 mg per
square cm etc. including all accessories like swing door clousure, swing door lock,
swing door mohiar, labour charge, fabrication, fitting fixing in position, carriage and
electricity charge keeping provision for fitting 5 mm thick glass including neoprene
sealant etc. complete in all respect as per drawing and accepted by the Engineer.
(Total weight min 23 kg/m2)
14.1.1
S.S colour
sqm
Tk.
6,148.00
14.1.2
Bronze colour
sqm
Tk.
6,052.00
14.1.3
Silver colour
sqm
Tk.
5,913.00
14.2
Supplying fitting and fixing of Aluminium swing door as per the U.S. Architectural
Aluminium Manufacturers Association (AAMA) standard specification having 1.8 mm
thick wall frame size 101.60 mm. 44.45 mm. 83.21 mm). 2.33 mm thick shutter size
(54 mm, 46 mm), 0.99 mm thick door glass bit (size 16.54 mm. 14.49 mm 0.115
kg/m), 2.5 mm thick clousure section (size 101.60 mm, 42.93 mm 1.2 mm), 106.60
mm clousure cover (0.45 kg/m), 4 mm thick floor bottom (size 101.60 mm. 12.70 mm
1 kg/m), 1.8 mm thick shutter bottom (size 82.6 mm, 43.99 mm, 0.60 kg/m), 1.8 mm
thick shutter top (size 51 mm, 43.99 mm, 1.88 kg/m) and 2.3 mm to 4.01 mm thick
handle (size 101.60 mm, 38.10 mm, 25.40 mm short, 1.35 kg/m) section of all
aluminum members will be anodized to aluminium bronze/silver colour with a coat
not less than 15 micrones in thickness and density of 4 mg per square cm etc.
including all accessories like swing door clousure, swing door lock, swing door
mohiar, labour charge, fabrication, fitting fixing in position, carriage and electricity
charge keeping provision for fitting 5 mm thick glass including neoprene sealant etc.
complete in all respect as per drawing and accepted by the Engineer.
(Total weight min 23 kg/m2)
14.2.1
S.S colour
sqm
Tk.
5,966.00
14.2.2
Bronze colour
sqm
Tk.
5,890.00
14.2.3
Silver colour
sqm
Tk.
5,781.00
Item No.
120
Description of Item
Unit
Unit Rate
14.3
Supplying, fitting and fixing of Aluminium composite swing doors with fixed
partition as per the U. S. Architectural Aluminium Manufacturers Association
(AAMA) standard specification having 1.5 mm thick wall frame (size101.60, 44.45
mm, 0.86 kg/m), 1.8 mm thick shutter side (size 54 mm, 46 mm, 1.2 kg/m ), 1 mm
thick door glass bit (size 16.54 mm, 14. 49 mm, 0.115 kg/m), 1.8 mm thick closure
section (size 101.54 mm, 42.93 mm, 1.20 kg/m), 1.5 thick closure cover (101.60
mm, 0.45 kg/m), 4 mm thick floor bottom (size 101.60 mm, 12.70 mm, 1 kg/m), 1.8
mm thick shutter bottom (size 86.60 mm, 43.99 mm , 0.60 kg/m), 1.8 mm thick
shutter top (size 51 mm, 43.99 mm, 1.88 kg/m) 2.3mm to 4.01mm thick handle
(short) (size 101.60 mm, 38.10 mm, 25.40 mm, 1.35 kg/m), 1.5 mm thick top and
side (size 101.60 mm, 44.45 mm, 1.3 kg/m), 1.50 mm thick bottom (size 101.35 mm,
44.45 mm, 1.10 kg/m), 1.50 mm thick bottom cover (44.32 mm, 19.61mm, 0.392
kg/m), 1.50 mm thick grouve cover size 83.21 mm, 16.00 mm, 0.57 kg/m), 0.99 mm
thick fixed glass protector (size 39.09 mm, 14.81 mm, 0.188 kg/m), 0.99 mm thick
fixed glass protector bit (size 15.75 mm, 14.81 mm, 0.13 kg/m) section of all
aluminium members will be anodized to aluminium bronze/silver colour with a coat
not less 15 microns in thickness and density of 4 mg per square cm etc. (Total
weight min 69.699 kg) keeping provision for 5mm of glass panes with cost
including all accessories like swing door clouser, swing door lock , swing door
mohair, flush bolt , bolts and nuts including sealants, labour charge for fitting , fixing
by angles, screws, mohiar, washer, machinery, cost of fabrication, making the
grooves, mending good the damages, electricity etc. complete in all respect as per
drawing and accepted by the Engineer.
14.3.1
S.S colour
sqm
Tk.
3,085.00
14.3.2
Bronze colour
sqm
Tk.
3,040.00
14.3.3
Silver colour
sqm
Tk.
2,982.00
14.4
Supplying, fitting and fixing of Aluminium sliding doors as per the U.S. Architectural
Aluminium Manufacturers Association (AAMA) standard specification having 1.2 mm
thick outer bottom (size 75.50 mm, 17.79 mm, 0.528 kg/m), 1.2 mm thick outer top
(size 75.50 mm, 26.80 mm, 0.78 kg/m) 1.2 mm thick shutter top (size 33 mm, 26.80
mm, 0.536 kg/m), 1.2 mm shutter bottom (size 60 mm, 24 mm, 0.736 kg/m), 1.2 mm
thick outer side(size 75.50 mm, 19.90 mm, 0.616 kg/m) 1.5 mm thick shutter lock
(size 49.20 mm, 26.20 mm, 0.661 kg/m), 1.2 mm thick inter lock (size 34.40 mm,
32.10 mm, 0.665 kg/m), 1.2 mm thick shutter divider (size 31.75 mm, 0.535 kg/m)
sections all aluminium members (Total weight 14.789 kg) will be anodized to
aluminium bronze/silver colour with a coat not less than 15 microns in thickness and
density of 4 mg per square cm etc. including all accessories like handle, sliding
door key lock , sliding door wheel, sliding door mohiar, sliding door neoprene, bolts
and nuts including sealants, keeping provision for fitting 5mm thick glass including
labour charge for fitting of accessories, making grooves and mending good
damages, carriage, and electricity complete in all respect as per drawing and
accepted by the Engineer. Size up to: 2100 mm x 2100 mm
14.4.1
S.S colour
sqm
Tk.
2,447.00
14.4.2
Bronze colour
sqm
Tk.
2,413.00
14.4.3
Silver colour
sqm
Tk.
2,366.00
Item No.
121
Description of Item
Unit
Unit Rate
14.5
Supplying, fitting and fixing of Aluminium sliding doors as per the U.S. Architectural
Aluminium Manufacturers Association (AAMA) standard specification having 1.2 m
mm thick outer bottom (size 75.50 mm, 17.79 mm, 0.528 kg/m), 1.2 mm thick outer
top (size 75. 50 mm, 26.80 mm 0.78 kg/m), 1.2 mm thick shutter top (size 33 mm,
26.80 mm, 0.536 kg/m), 1.2 mm thick shutter bottom (size 60 mm, 24 mm, 0.736
kg/m), 1.2 mm thick side (size 75.50 mm, 19.90 mm, 0.616 kg/m), 1.2 mm thick
sliding fixed side (31 mm, 26 mm , 0.422 kg/m) 1.2 mm thick shutter lock (size 49.20
mm , 26. 20 mm , 0.661 kg/m), 1.2 mm thick inter lock (size 34.40 mm, 32.10 mm,
0.665 kg/m) 1.2 mm thick shutter divider (size 31.75 mm, 0.535 kg/m) and 1.4 mm to
1.5 mm thick spandrel (7.14 mm, 0.70 kg/m) sections all aluminium members (total
weight 19.72 kg) will be anodized to aluminium bronze/silver colour with a coat not
less than 15 microns in thickness and density of 4 mg per square cm etc. including
all accessories like sliding door key lock, sliding door whee , sliding door mohiar,
sliding door neoprene, bolts and nuts including sealants, keeping provision for fitting
5mm thick glass including labour charge for fitting of accessories, making grooves
and mending good damages, carriage, and electricity complete in all respect as per
drawing and accepted by the Engineer. Size up to: 1800 mm x 2100 mm
14.5.1
S.S colour
sqm
Tk.
3,336.00
14.5.2
Bronze colour
sqm
Tk.
3,282.00
14.5.3
Silver colour
sqm
Tk.
3,223.00
14.6
Supplying, fitting and fixing of Aluminium sliding window as per the U.S.
Architectural Aluminium Manufacturers Association (AAMA) standard specification
having 1.2 mm thick outer bottom (size 75.50 mm, 32mm), 1.2 mm thick outer top
(size 75.50 mm, 16.80 mm), 1.2 mm thick shutter top (size 33 mm.26.80, 22 mm),
1.2 mm thick shutter bottom (size 60mm, 24.40 mm), 1.2 mm thick outer side (size
75.50 mm,19.90 mm), 1.2 mm thick sliding fixed side (size 31 mm, 26 mm),1.2 mm
thick shutter lock (size 49.20 mm 26.20 mm) and 1.2 mm thick inter lock (size 34.40
mm, 32.10 mm) sections all aluminium members (total weight kg/sqm) will be
anodized to aluminium bronze/silver colour with a coat not less than 15 micron in
thickness and density of 4 mg per square cm etc. including all accessories like
sliding door key lock, sliding door wheel, sliding door mohiar, sliding door neoprene,
bolts and nuts including sealants, keeping provision for fitting 5 mm thick glass
including labour charge for fitting of accessories, making grooves and mending good
damages, carriage, and electricity complete in all respect as per drawing and
accepted by the Engineer.
14.6.1
Size up to: 1500 mm x 1400 mm. (total weight minimum 9.081 kg)
14.6.1.1
S.S colour
sqm
Tk.
2,728.00
14.6.1.2
Bronze colour
sqm
Tk.
2,681.00
14.6.1.3
Silver colour
sqm
Tk.
2,620.00
14.6.2
14.6.2.1
S.S colour
sqm
Tk.
3,682.00
14.6.2.2
Bronze colour
sqm
Tk.
3,620.00
14.6.2.3
Silver colour
sqm
Tk.
3,537.00
Item No.
14.7
122
Description of Item
Unit
Unit Rate
14.7.1
14.7.1.1
S.S colour
sqm
Tk.
4,143.00
14.7.1.2
Bronze colour
sqm
Tk.
4,072.00
14.7.1.3
Silver colour
sqm
Tk.
3,991.00
14.7.2
14.7.2.1
S.S colour
sqm
Tk.
4,678.00
14.7.2.2
Bronze colour
sqm
Tk.
4,600.00
14.7.2.3
Silver colour
sqm
Tk.
4,509.00
14.7.3
14.7.3.1
S.S colour
sqm
Tk.
9,564.00
14.7.3.2
Bronze colour
sqm
Tk.
9,424.00
14.7.3.3
Silver colour
sqm
Tk.
9,252.00
Item No.
123
Description of Item
Unit
Unit Rate
14.8
Supplying, fitting and fixing of Aluminium fixed composite window as per the U.S.
Architectural Aluminium Manufacturers Association (AAMA) standard specification
having 1.2 mm thick outer bottom (size 75.50 mm, 32 mm, 0.695 kg/m), 1.2 mm thick
outer top (size 75.50mm, 26.80 mm, 0.78 kg/m), 1.2 mm thick shutter top (size 33
mm, 26.80 mm, 0.536 kg/m), 1.25 mm thick shutter bottom (size 60 mm, 24.40 mm,
0.736 kg/m), 1.2 mm thick outer side (size 75.50 mm, 19.90 mm, 0.616 kg/m), 1.2
mm thick sliding fixed side (size 31 mm, 26 mm, 0.422 kg/m), 1.2 mm thick shutter
lock (size 49.20 mm, 26.20 mm, 0.661 kg/m), 1.2 mm thick inter lock (size 34.40 mm,
32.10 mm 0.665 kg/m) 1.2 mm thick bottom cover (size 37.78 mm, 31.78 mm, 0.313
kg/m), 1.2 mm thick grouve cover (76.20 mm, 38.10 mm, 0.912 kg/m), 1.2 mm thick
grouve cover ( size 57.15 mm, 15.80 mm, 0.452 kg/m) and 1.2 mm thick top and side
(size 76.20 mm, 38.10 mm, 0.3 kg/m) sections all aluminium members (total weight
12.297 kg) will be anodized aluminium bronze/silver colour with a coat not less than
15 micron in thickness and density of 4 mg per square cm etc. including all
accessories like sliding door key lock, sliding door wheel, sliding door mohiar, sliding
door neoprene, bolts and nuts including sealants, keeping provision for fitting 5 mm
thick glass including labour charge for fitting of accessories, making grooves and
mending good damages, carriage, and electricity complete in all respect as per
drawing and accepted by the Engineer. Size up to: 1500mm x 2100 mm.
14.8.1
S.S colour
sqm
Tk.
2,918.00
14.8.2
Bronze colour
sqm
Tk.
2,870.00
14.8.3
Silver colour
sqm
Tk.
2,771.00
14.9
Supplying, fitting and fixing of Aluminium top hung/casement windows as per the
U.S. Architectural Aluminium Manufacturers Association (AAMA) standard
specification having 1.2 mm thick casement outer (size 38.86 mm, 36.36 mm,
0.395kg/m), 1.9 mm thick casement shutter (size 47.62 mm, 28.57 mm, 0.692 kg/m),
and 1.245 mm thick shutter glass clip (size 15.87 mm, 27 mm, 0.188 kg/m) sections
of all aluminium members will (total weight 7.584 kg) be anodized to aluminium
bronze/silver colour with a coat not less than 15 micron in thickness and density of 4
mg per square cm etc. including all accessories 4-bar hinge, casement handle, bolts
and nuts keeping provision for fitting 5 mm thick glass including labour charge for
fitting of accessories, making grooves and mending good damages, carriage, and
electricity complete in all respect as per drawing and accepted by the Engineer.
14.9.1
S.S colour
sqm
Tk.
9,629.00
14.9.2
Bronze colour
sqm
Tk.
9,531.00
14.9.3
Silver colour
sqm
Tk.
9,386.00
14.10
Supplying fitting and fixing of Aluminium corrugated curtain wall as per the U.S.
Architectural Aluminium Manufacturers Association (AAMA) standard specification
having 1.2 mm thick bottom cover (size 37.78 mm 31.78 mm, 0.313 kg/m), 1.2 mm
thick grouve cover (size 76.20 m 38.10 mm, 0.912 kg/m), 1.2 mm thick grouve cover
(size 57.15 mm, 15.80 mm 0.45 kg/m), 1.2mm thick top and side (size 76.2 mm,
57.15 mm, 0.153 kg/m) and 1.8 mm thick spandrel (7.14 mm, 0.70 kg/m) sections of
all aluminium members will be anodized to aluminium bronze/silver colour with a coat
not less than 15 micron in thickness and density of 4 mg square cm etc. including all
accessories like rivet, screws fixed neoprene etc. complete in all respect as per
drawing and accepted by the Engineer.
Item No.
124
Description of Item
Unit
Unit Rate
14.10.1
14.10.1.1
S.S colour
sqm
Tk.
4,830.00
14.10.1.2
Bronze colour
sqm
Tk.
4,726.00
14.10.1.3
Silver colour
sqm
Tk.
4,622.00
14.10.2
14.10.2.1
S.S colour
sqm
Tk.
6,143.00
14.10.2.2
Bronze colour
sqm
Tk.
6,021.00
14.10.2.3
Silver colour
sqm
Tk.
5,881.00
14.11
Supplying fitting and fixing of Aluminium fixed fan light as per the U.S. Architectural
Aluminium Manufacturers Association (AAMA) standard specification mm, 0.313
kg/m) 1.2 mm thick bottom cover (size 76.2 mm, 38.10 mm, 0.76 kg/m) and 2.5 mm
thick grouve cover section (size 57.15mm, 15.80 mm, 0.425 kg/m) and 1.2 thick top
and side section (76.20 mm, 16 mm, 38.10 mm, 0.961 kg/m) fixed with above
mentioned frames and all aluminium members (Total weight 5.365kg) will be
anodized to aluminium bronze/silver colour with a coat not less than 15 micron in
thickness and density of 4 mg per square cm etc. including all accessories,
neoprene, sealant, nut and bolt etc. complete in all respect as per drawing and
accepted by the Engineer.
14.11.1
S.S colour
sqm
Tk.
3,657.00
14.11.2
Bronze colour
sqm
Tk.
3,606.00
14.11.3
Silver colour
sqm
Tk.
3,405.00
14.12
Supplying fitting and fixing of Aluminium fixed louver as per the U.S. Architectural
Aluminium Manufacturers Association (AAMA) standard specification having 1.2mm
thick wall frame (size 76.20 mm, 38.10 mm, 0.707 kg/m), 5 mm thick louver section
(size 55.02 mm, 37.39 mm, 0.22kg/m) and 2.50 mm thick louver outer section (size
39.67 mm, 15.06 mm, 0.265 kg/m) and inner inclined aluminium louver section fixed
with above mentioned frame and all aluminium members (total weight 7.992 kg) will
be anodized to aluminium bronze/silver colour with a coat not less than 15 micron in
thickness and density of 4 mg per square cm etc. including all accessories,
neoprene, sealant, nuts and bolts etc. complete in all respect as per drawing and
accepted by the Engineer.
14.12.1
S.S colour
sqm
Tk.
6,546.00
14.12.2
Bronze colour
sqm
Tk.
6,388.00
14.12.3
Silver colour
sqm
Tk.
6,231.00
Item No.
125
Description of Item
Unit
14.13
Supplying, fitting, fixing of Aluminium sliding fly proof Netting shutter as per the
U.S. Architectural Aluminium Manufacturers Association (AAMA) standard
specification having 1.2mm thick 38mm x 18mm aluminium outer frame, 1.2mm thick
38mm x 12mmmosquito net shutter frame (mesh section).All aluminium members
(total weight 12.79 kg) will be anodized to aluminium SS/ bronze/silver colour with a
coat not less than 15 micron in thickness and density of 4 mg per square cm etc.
including all accessories like wheel, sealent, rubber, bolts and nuts keeping provision
for fitting fiber mesh including labour charge for fitting of accessories, making
grooves and mending good damages, carriage, and electricity complete in all
respect as per drawing and accepted by the Engineer.
sqm
Tk.
2,069.00
14.14
Supplying, fitting and fixing in Aluminium door frames, windows, partitions and
curtain wall distortion free glass of approved quality and shade including cost of
fitting fixing all necessary accessories etc. complete in all respect as per drawing and
accepted by the Engineer.
14.14.1
sqm
Tk.
1,077.00
14.14.2
sqm
Tk.
1,310.00
14.14.3
sqm
Tk.
1,224.00
14.14.4
sqm
Tk.
1,416.00
14.15
sqm
Tk.
5,994.00
14.16
Supplying, fitting and fixing of aluminium curtain wall with aluminium top
hung/casement windows as per the US Architectural aluminium Manufacturer's
Association (AAMA) Standard Specification having 100 mm , 50mm, 2mm curtain
wall sub-mullim outer and inner frame, 15 mm thick casement outer frame (size
38.86 mm 36.6mm), 1.9 mm thick casement shutter (size 47.62mm, 28.57mm,) 1.2
mm thick shutter glass strips, all aluminium member will be powder coated with coal
not less than 1.5 micron in thickness including all accessories 4 bar hinge casement
handle, 50 m x 50mm x 6m aluminium angle, steel rowel bolt, screws , rivets norton
tape masking tape, structural sealant, gum bracket rod etc. all complete in all respect
as per drawing and direction of the Engineer in charge.
sqm
Tk.
8,238.00
14.17
Supplying, fitting and fixing of aluminium curtain wall and aluminium top
hung/basement windows ad per the US Architectural aluminium Manufacturer's
Association (AAMA) Standard Specification having 50 mm , 50mm, 2mm curtain wall
sub-mullim outer and inner frame, 15 mm thick casement outer frame (size 38.86
mm 36.6mm), 1.9 mm thick casement shutter (size 47.62mm, 28.57mm,) 1.2 mm
thick shutter glass strips, all aluminium member will be powder coated with coal not
less than 1.5 micron in thickness including all accessories 4 bar hinge casement
handle, 50 m x 50mm x 6m aluminium angle, steel rowel bolt, screws , rivets norton
tape masking tape, structural sealant, gum bracket rod etc. all complete in all respect
as per drawing and direction of the Engineer in charge.
sqm
Tk.
6,901.00
Unit Rate
Item No.
126
Description of Item
Unit
Unit Rate
Description of Item
Unit
Unit Rate
15.1
Minimum 12 mm thick cement sand (F.M. 1.2) plaster (1:4) with fresh cement to
wall both inner-and outer surface, finishing the corner and edges including washing
of sand cleaning the surface, scaffolding and curing at least for 7 days, cost of water,
electricity and other charges etc. all complete in all respect as per drawing and
accepted by the Engineer. (Cement: CEM-II/A-M). Ground floor.
sqm
Tk.
214.00
15.2
Minimum 12 mm thick cement sand (F.M. 1.2) plaster with neat cement finishing
to plinth wall (1:4) with cement up to 150 mm below ground level with neat cement
finishing including washing of sand, finishing the edges and corners and curing at
least for 7 days, cost of water, electricity and other charges etc. all complete in all
respect as per drawing and accepted by the Engineer. (Cement: CEM-II/A-M)
Ground floor.
sqm
Tk.
246.00
15.3
Minimum 12 mm thick cement sand (F.M. 1.2) plaster with neat cement finishing
to dado (1:4) with cement up to 150 mm with neat cement finishing including
washing of sand, finishing the edges and corners and curing at least for 7 days, cost
of water, electricity and other charges etc. all complete in all respect as per drawing
and accepted by the Engineer. (Cement: CEM-II/A-M). Ground floor.
sqm
Tk.
263.00
15.4
Minimum 12 mm thick cement sand (F.M. 1.2) plaster (1:6) having with fresh
cement to wall both inner-and outer surface, finishing the corner and edges including
washing of sand cleaning the surface, scaffolding and curing at least for 7 days, cost
of water, electricity and other charges etc. all complete in all respect as per drawing
and accepted by the Engineer.(Cement: CEM-II/A-M)Ground floor.
sqm
Tk.
198.00
15.5
Minimum 6 mm thick cement sand (F.M. 1.2) plaster (1:4) with fresh cement to
ceiling R.C.C. columns, beams, surface of stair case, sunshades, cornices, railings,
drop wall, louvers, fins and finishing the corners and edges including washing of
sand cleaning the surface, scaffolding and curing at least for 7 days, cost of water,
electricity and other charges etc. all complete in all respect as per drawing and
accepted by the Engineer. (Cement: CEM-II/A-M). Ground floor.
sqm
Tk.
186.00
15.6
Minimum 6 mm thick cement sand (F.M. 1.2) plaster (1:3) with fresh cement to
ceiling R.C.C. columns, beams, surface of stair case, sunshades, cornices, railings,
drop wall, louvers, fins and finishing the corners and edges including washing of
sand cleaning the surface, scaffolding and curing at least for 7 days, cost of water,
electricity and other charges etc. all complete in all respect as per drawing and
accepted by the Engineer. (Cement: CEM-II/A-M). Ground floor.
sqm
Tk.
191.00
15.7
Flush pointing to brick wall with cement sand (F.M. 1.2) mortar (1:2) with cement
including raking out the joints, and necessary scaffolding curing at least for 7 days,
cost of water, electricity and other charges etc. all complete in all respect as per
drawing and accepted by the Engineer. (Cement: CEM-II/A-M). Ground floor.
sqm
Tk.
117.00
15.8
Rule pointing to brick wall with cement sand (F.M. 1.2) mortar (1:2) with fresh
cement and raking out the joints, scaffolding, curing at least for 7 days, cost of water,
electricity and other charges etc. all complete in all respect as per drawing and
accepted by the Engineer. (Cement: CEM-II/A-M). Ground floor.
sqm
Tk.
149.00
Item No.
127
Description of Item
Unit
15.9
Raised or tack pointing work to brick wall with cement sand (F.M. 1.2) mortar
(1:2) with fresh cement minimum 12 x 20 mm in size including raking out the joints
and necessary scaffolding, curing at least for 7 days, cleaning each and every brick,
cutting the bricks with pumic stone where necessary etc. all complete in all floors,
cost of water, electricity and other charges etc. all complete in all respect as per
drawing and accepted by the Engineer. (Cement: CEM-II/A-M) Ground floor.
sqm
Tk.
359.00
15.10
Providing drip course or Nosing at the edge of sunshade or cornice with cement
sand (F.M. 1.2) mortar (1:2) with fresh cement including scaffolding, curing at least
for 7 days, cost of water, electricity and other charges etc. all complete in all respect
as per drawing and accepted by the Engineer.(Cement: CEM-II/A-M)Ground floor.
rm
Tk.
91.00
15.11.1
Making groove in plaster on outside wall upto 50mm X 6mm size including
scaffolding, curing etc. complete as per drawing and accepted by the Engineer.
rm
Tk.
18.00
15.11.2
Making groove in plaster on outside wall upto 38mm X 6mm size including
scaffolding, curing etc. complete as per drawing and accepted by the Engineer..
rm
Tk.
27.00
15.12
Extra rate for plaster and all types of pointing shall be incorporated in the estimate
15.12.1
sqm
Tk.
11.00
15.12.2
Add for each additional floor from 6th floor to 9th floor
sqm
Tk.
17.00
15.12.3
sqm
Tk.
22.00
15.13
Average 100 mm thick finished lime terracing with 20 mm down graded first class
brick chips (Khoa), surki from 1st class bricks and min lime content 500kg per
2.83cubic meter (stone lime brought at site, not being powdered in open air and to be
slaked in presence of engineer-in-charge and to be measured in volume three days
after slaking for using in the mix) in the proportion 7:2:2 (brick chips : surki : lime)
including preparation of the mix on the ground by making a suitable platform under
proper polythene cover. Cutting the mix twice daily with limewater (1:10) at least for 7
days until the mix attain desirable consistency. Laying the mix in proper slope,
beating the same with standard koppa for minimum 7 days to gain maximum
consolidation, making ghoondy and neat finishing with lime Surki mortar (1:2) and
curing for 21 days providing polythene cover after each day work and cleaning etc.
complete in all respect accepted by the Engineer.
cum
Tk.
12,015.00
15.14
sqm
Tk.
1,777.00
15.15
75 x 75 mm cornice of brick masonry in cement sand (F.M. 1.2) mortar (1:6) having
minimum 12 mm thick cement sand (F.M. 1.2) plaster (1:6) including scaffolding and
curing at least for 7 days in all floors accepted by the Engineer. (Cement: CEM-II/AM)
rm
Tk.
174.00
15.16
sqm
Tk.
211.00
Unit Rate
Item No.
128
Description of Item
Unit
Unit Rate
Description of Item
Unit
Unit Rate
16.1
White washing by three coats, lime mixture prepared at least 12 hours before use,
slacking stone lime, supply of gums, blue, stirring thoroughly, removing the floating
materials from the mixer, surface cleaning to free from all foreign materials before
application of each coat, applying one vertical and one horizontal wash for each coat
and successive coat is to be applied after drying up of previous coat including hair
brass, providing necessary scaffolding and cleaning plinth, floors, doors, windows,
portions and ventilators by washing, rubbing, oiling if necessary after white wash for
all floors including cost of water, electricity and other charges etc. complete in all
respect in all floors and accepted by the Engineer.
sqm.
Tk.
18.00
16.2
Colour wash with yellow orchard/any other colour pigment by two coats over a
prime coat of white wash, lime mixture prepared at least 12 hours before use,
slacking stone lime, supply of gums, blue, stirring thoroughly, removing the floating
materials from the mixer, surface cleaning to free from all foreign materials before
application of each coat, applying one vertical and one horizontal wash for each coat
and successive coat is to be applied after drying up of previous coat including hair
brass, providing necessary scaffolding and cleaning plinth, floors, doors, windows,
portions and ventilators by washing, rubbing, oiling if necessary after white wash for
all floors including cost of water, electricity and other charges etc. complete in all
respect in all floors and accepted by the Engineer.
sqm.
Tk.
20.00
16.3
Cement Paint of approved quality and colour delivered from authorized local agent
of the manufacturer in a sealed container, made from water based powder mixed
with water (1:1), applying first coat, curing the same after six hours for 24 hours,
second coat applied and curing the same for 7 (seven) days etc, taking care and
cleaning the surface fully from grease, oily substances, old paints, lime wash,
fungus, algae etc., sand papering the surface before applying 1st and 2nd coat,
complete including cost of electricity, water and other changes etc. complete in all
floors and accepted by the Engineer.
sqm.
Tk.
128.00
16.4
sqm.
Tk.
189.00
16.5
sqm.
Tk.
193.00
16.6
Painting to door and window frames and shutters in two coats with approved best
quality and colour of synthetic enamel paint delivered from authorized local agent
of the manufacturer in a sealed container, having highly water resistant, high
bondibilty, flexible, using specific brand thinner applied by brass/roller/spray over a
coat of priming elapsing time for drying including surface cleaning from dust, oil or
dirt, smoothening, finishing and polishing with sand paper and necessary tools,
scaffolding, testing charges etc. all complete in all floors approved and accepted by
the Engineer.
sqm.
Tk.
183.00
Item No.
129
Description of Item
Unit
Unit Rate
16.7
Approved best quality and colour synthetic polyvinyl distemper delivered from
authorized local agent of the manufacturer in a sealed container, applying to wall and
ceiling in 2 coats over a coat of brand specified primer or sealer elapsing specified
time for drying/ recoating matt finish including cleaning and sand papering making
the surface free from loose and flaky materials, dirt, grease, wax, polish, scraping all
chalked and scaled materials, applying the paint by brush/roller and necessary
scaffolding etc. all complete in all floors accepted by the Engineer.
sqm.
Tk.
147.00
16.8.1
Plastic emulsion paint of approved best quality and colour delivered from
authorized local agent of the manufacturer in a sealed container, applying to wall and
ceiling in two coats over a coat of brand specified primer or sealer elapsing
specified time for drying or recoating including cleaning drying, making free from dirt,
grease, wax, removing all chalked and scaled materials, fungus, mending good the
surface defects, sand papering the surface and necessary scaffolding, spreading by
brush/ roller/spray etc. all complete in all floors accepted by the Engineer.
sqm.
Tk.
159.00
16.8.2
Plastic emulsion paint of approved best quality and colour delivered from
authorized local agent of the manufacturer in a sealed container, applying to wall and
ceiling in two coats over lime putty of specified brand applied on primer or sealer
elapsing specified time for drying/recoating including cleaning drying, making free
from dirt, grease, wax, removing all chalked and scaled materials, fungus, mending
good the surface defects, sand papering the surface and necessary scaffolding,
spreading by brush/ roller/spray etc. all complete in all floors accepted by the
Engineer.
Lime putty to be applied as per manufacturer instructions approved and accepted by
the Engineer.
sqm.
Tk.
221.00
16.9.1
Acrylic emulsion painting (silky finish) of approved best quality and colour
delivered from authorized local agent of the manufacturer in a sealed container,
applying to wall and ceiling in two coats over a coat of brand specified primer or
sealer including cleaning, drying, making free from loose and flaky materials, dirt,
grease, wax, removing all chalked and scaled materials, fungus, elapsing specified
time for drying, re-coating, flaking paints, mending good the surface defects, sand
papering the surface, smoothing by putty and necessary scaffolding, testing charges,
applied by brush/roller/spray etc. all complete in all floors accepted by the Engineer.
sqm.
Tk.
162.00
16.9.2
Acrylic emulsion painting (silky finish) of approved best quality and colour
delivered from authorized local agent of the manufacturer in a sealed container,
applying to wall and ceiling in two coats over lime putty of specified brand applied
on primer or sealer elapsing specified time for drying/recoating including cleaning
drying, making free from dirt, grease, wax, removing all chalked and scaled
materials, fungus, mending good the surface defects, sand papering the surface and
necessary scaffolding, spreading by brush/ roller/spray etc. all complete in all floors
accepted by the Engineer.
sqm.
Tk.
218.00
16.10
omitted
16.11
omitted
16.12
Textured paint of approved best quality and colour delivered from authorized local
agent of the manufacturer in a sealed container, applying to wall and ceiling
including cleaning, drying, making free from dirt, grease, wax, removing all chalked
and scaled materials, fungus if required must be treated with fungicidal solution,
flaking paints, mending good the surface defects, sand preparing the surface and
necessary scaffolding, applied by brush/roller/spray etc. all complete in all floors
accepted by the Engineer.
sqm.
Tk.
578.00
Item No.
130
Description of Item
Unit
16.13
Chlorinated rubber paint of approved quality and colour delivered from authorized
local agent of the manufacturer in a sealed container, applying to concrete surfaces
and walls in three coats elapsing specified time for drying and re-coating including
cleaning, drying, making free from dirt, grease, wax, removing all chalked and scaled
materials, fungus (if required must be treated with fungicidal solution) flaking paints,
washing the surface with soap water/caustic soda, mending good the surface
defects, smoothening the surface by putty sand papering the surface and necessary
scaffolding, applied by brush/roller/spray etc. all complete in all floors and accepted
by the Engineer.
sqm.
Tk.
306.00
16.14
French polishing to door and window frames and shutters three coats over a coat
of priming including putty, cleaning finishing and polishing with sand paper etc. all
complete in all floors accepted by the Engineer.
sqm.
Tk.
293.00
16.15
Wood varnishing of approved quality and colour delivered from authorized local
agent of the manufacturer in a sealed container using brand specified thinner to door
and window frame and shutter in three coats, applied with brush including cleaning
oil, grease, dirt, making dry, sand papering, if required washing with weak detergent
solution, stripping out the colour straps, finishing the surface, etc. all complete in all
floors accepted by the Engineer.
16.15.1
Yacht
sqm.
Tk.
147.00
16.15.2
Egg-shell
sqm.
Tk.
150.00
16.15.3
Matt
sqm.
Tk.
149.00
Unit Rate
Item No.
131
Description of Item
Unit
Unit Rate
Description of Item
Unit
Unit Rate
17.1
rm.
Tk.
1,167.00
17.2
Constructing surface drain of 600 mm (av.) depth and 225 mm clear width at
the bottom and 525 mm at the top having 125 mm thick cement concrete (1:2:4) curb
up to 300 mm from the bottom over one layer of polythene on top brick flat soling and
the side slopes of the remaining 300 mm height provided with 125 mm thick first
class brick work in cement mortar (1:6) including minimum 12 mm thick cement sand
(F.M. 1.2) plaster (1:3) including neat cement finishing the surfaces and back of the
drain up to 150 mm below ground level with fresh cement (conforming to BDS 232)
curing at least for 7 days including excavation of all kinds of soil, back filling with fine
sand (F.M. 0.8) consolidating and dressing, including cost of water, electricity, other
charges etc. complete and accepted by the Engineer. (Cement: CEM-II/A-M)
rm.
Tk.
2,340.00
17.3
Providing apron with 50 mm thick cement concrete (1:2:4) with cement, coarse sand
and picked jhama chips including breaking chips and one layer brick flat soling at
bottom with first class or picked jhama bricks including cutting earth for preparation
of bed and filling the interstices with local sand (F.M. 0.8) including finishing,
dressing, curing at least for 7 days etc. all complete, including cost of water,
electricity, other charges accepted by the Engineer. (Cement: CEM-II/A-M)
sqm.
Tk.
832.00
17.4.1
Supplying, laying, fitting fixing best quality 225 mm dia (internal) machine made
R.C.C. pipe over 100 mm thick cement concrete (1:3:6) at base and sides including
single brick flat soling and gasket with cement mortar (1:4) joints, cutting and filling
trenches up to required depth including excavation of soil etc. all complete in all
respects as per type plan and accepted by the Engineer (average depth of trench is
3'-6"). (Cement: CEM-II/A-M)
rm.
Tk.
911.00
17.4.2
rm.
Tk.
1,188.00
17.5
Supplying, laying and fitting-fixing 900 mm dia RCC pipe of approved quality and
accepted by the Engineer. [Rate is excluding cost for excavation, back-fill, materials
for back-fill and bedding]
rm.
Tk.
9,661.00
Item No.
132
Description of Item
Unit
Unit Rate
Description of Item
Unit
Rate
18.1.1
Supplying, fitting and fixing plain particle board complying unit wt 499 to
550kg/m3 , bending strength 0.35N/mm2 , max swelling 8% , moisture content not
more than 10% , for ceiling of 12 mm thick with best quality and well seasoned
Garjan wood frame of section 75 x 38 mm at 600 x 600 mm in grid suspended from
ceiling or roof or beam by 12 SWG double ply G.I. wire fixed to the ceiling by rowel
plug, screws, hooks, nails etc. maintaining straight lines and desired finished level at
bottom face with vertical strut as required including cutting holes in slabs or beams
by electric drill machine and mending good the damages, if any, during execution of
the work including cost and carriage of all materials, accessories, labour for
installation, electricity charge, scaffolding, screws, nails etc. including. painting 2
coats over a coat of priming with best quality and approved colour synthetic enamel
as per item no 16.6 of this schedule of etc. all complete as per drawing design and
accepted by the Engineer. (All sizes of wood are finished)
sqm.
Tk.
2,674.00
18.1.2
Supplying, fitting and fixing plain particle board as in itme 18.11 for ceiling of 12
mm for auditorium and other type of tall structures beyond 4 m up to 8 m,
which do not cover the above item [Item No. 153(a)]. Description of item is the same
as in item No. 153(a) above.
sqm.
Tk.
2,860.00
18.1.3
Supplying, fitting and fixing of ceiling with 12 mm thick melamine board laminated
by mechanical hot press with a milk white PVC membrane in aluminium frame
suspended from ceiling.
sqm.
Tk.
1,522.00
18.2.1
Supplying, fitting and fixing gypsum board ceiling of 9 mm thick board laminated by
mechanical hot press with a milk white PVC membrane with Aluminium T-bar frame
in natural anodized finish at 600 x 600 mm in grid suspended from ceiling by 12
SWG double ply wire fixed to the ceiling by rowel plug, screws, hooks, nails etc.
maintaining straight lines and desired finished level a bottom face with vertical
wooden strut as required including making holes in slabs, or beams by electric drill
machine and mending good the damages, if any, during execution of the work
including cost of all materials, electricity, accessories, scaffoldings, labour for
installation, screws, nails, etc. all complete as per drawing, design and accepted by
the Engineer.
sqm.
Tk.
1,692.00
18.2.2
sqm.
Tk.
1,962.00
18.2.3
Supplying, fitting and fixing of 9 mm thick perforated gypsum board false ceiling
with aluminium T bar frame in natural anodized frame at 600 mm x 600 mm grid
suspended from ceiling by 12 SWG double ply G.I. Wire
sqm.
Tk.
1,751.00
18.3.1
Supplying, fitting and fixing 12 mm thick Burma Teak (BT) Veneered board in
walling with best quality and well seasoned Garjan wood frame of section 75 x 38
mm at 600 x 600 mm in grid, fitted and fixed to wall by plugs, nails, screws etc.
including treatment of inner surface with termite and damp proofing agent
maintaining leveled and finished exposed faces including. making holes in wall and
mending good the damages. If any, during execution of the work including. cost and
carriage of all materials, electricity, accessories, labour for installation, scaffolding,
screws, nails etc. including French polishing 3 coats over a coat of priming as per
item No. 137 of the schedule etc. all complete as per design, approved sample and
accepted by the Engineer.
sqm.
Tk.
3,379.00
18.3.2
sqm.
Tk.
2,360.00
Item No.
133
Description of Item
Unit
Unit Rate
Description of Item
Unit
Rate
Manufacturing, supplying, fitting and fixing collapsible gate of any design and
shape made of 3/4" x 3/4" x 1/8" channel placed @ 112 mm c/c vertically and
connecting the same with each other by 20 x 3 mm M.S flat bar scissors 525 mm/
600 mm long provided in 3 rows including cutting the different M.S. members to
required sizes, fabricating, welding, riveting with required size rivets, providing
required size wheels, pulling handles on both sides, suitable locking arrangement,
electrodes, grease and finally placing the same in position in between 2 (two) Nos.
50 x 50 x 6 mm M.S. Tee rail made by welding 2 Nos. 50 x 6 mm M.S. flat bar fitted
and fixed at top and bottom with R.C.C. lintel/roof slab, floors and side wall with
required Nos. 150 mm to 225 mm long 38 x 6 mm M.S. flat bar clamps one end
welded with the gate member and the other end bifurcated and embedded in C.C. at
the respective point including cutting holes and mending good the damages by
pouring concrete (1:2:4) into the holes and finishing, etc complete, painting 2 (two)
coats with approved best quality synthetic enamel paint over a coat of anticorrosive
painting, both end carriage, including greasing, electrodes, curing etc. complete as
per drawing and design and accepted by the Engineer.
sqm.
Tk.
3,531.00
-do- -do- Collapsible gate made of 3/4" x 3/4" x 1/8" M.S. angle as vertical member
and 3/4" x 1/8" F.I bar as scissors.
sqm.
Tk.
4,045.00
19.1.3
-do- -do- Collapsible gate made of 1" x 1" x 1/8" M.S. angle as vertical member and
1" x 1/8" F.I bar as scissors.
sqm.
Tk.
4,876.00
19.2.1
Supplying, fitting, fixing, and installation of ordinary type M.S. gate (double leaf) of
any design and shape with 38 x 38 x 6 mm M.S. Angle outer frame having 16 mm
dia M.S. rod placed vertically @ 75 mm c/c. at bottom part and top part (arrows) and
also placed horizontally at bottom for interconnection of 16 mm dia M.S. rod placed
vertically as per design, the top part covered with 18 BWG M.S. sheet and fixed with
4 Nos. 38 x 6 mm F.I. bars placed diagonally and 4 Nos. 38 x 6 mm F.I. bars placed
horizontally and vertically all passing through the center, providing locking
arrangements on 3 mm thick M.S. plate one for main gate and one for minimum 300
x 1025 mm pocket gate with 38 x 38 x 6 mm M.S. angle and 16 mm dia M.S. rod
placed vertically @ 75 mm c/c, providing 38 x 38 x 6 mm M.S. angle clamps fitted
and fixed with the outer frame of the main gate, the clamp being embedded in R.C.C.
or R.C.C. core pillar with cement concrete (1:2:4) in masonry including cutting holes
and mending good the damages, finishing, curing etc. including riveting, welding as
and where necessary, painting two coats with approved quality of synthetic enamel
paint over a coat of priming of anti-corrosive paint etc. all complete as per drawing,
design and accepted by the Engineer. (Rate is excluding the cost of paint).
sqm.
Tk.
5,756.00
19.2.2
Manufacturing, supplying and fitting-fixing security door with 7/8 dia M.S. rod and
outer frame with 2 x 2 x M.S. angle complete as per drawing and accepted by
the Engineer.
sqm.
Tk.
10,070.00
Item No.
134
Description of Item
Unit
Unit Rate
19.3
Supplying, fitting, fixing, and installation of ordinary type M.S. security gate of any
design and shape with 50 x 50 x 6 mm M.S. angle outer frame and two 50 x 50 x 6
mm angle placed diagonally having 22 mm dia M.S. rod placed vertically @ 115 mm
c/c. and also 38 x 6 mm F.I placed horizontally, the bottom part covered with 3 mm
thick M.S. sheet providing locking arrangements on 3 mm thick M.S. plate providing
heavy type clamps fitted and fixed with the outer frame of the main gate, the clamp
being embedded in R.C.C. or R.C. core pillar with cement concrete (1:2:4) in
masonry including cutting holes and mending good the damages, finishing, curing
etc. including fabrication, riveting, welding as and where necessary, etc. all complete
as per drawing, design and accepted by the Engineer.
sqm.
Tk.
5,007.00
19.4
Supplying, fitting, fixing and installation ordinary type M.S. gate (double leaf) of
any design and shape with 38 x 38 x 6 mm M.S. angle box (made by welding 2 Nos.
38 x 38 x 6 mm angle) outer frame having 25 x 50 x 25 x 5 mm M.S. channel (made
by welding 2 Nos. of angle) placed part diagonally after cutting and shaping as per
requirement part horizontally @ 75 mm C/C the two part of each leaf being
separated by a vertical member of 38 x 38 x 6 M.S. box and welded the each ends of
diagonal and horizontal members properly with the box frame as per architectural
drawing providing full locking arrangement on 3 mm thick M.S. plates providing 38 x
38 x 6 mm M.S. angle clamps, fitting fixing with the outer frame of the gate the
clamp being embedded in R.C.C. pillars with cement concrete (1:2:4) including.
cutting holes and mending good the damages, finishing, curing and where necessary
painting two coats with approved quality of synthetic enamel paint over a coat of
priming of anticorrosive paint etc. all complete including making and providing 50 x 6
mm M.S. rail and 38 mm wheel for smooth movement of the gate etc. all complete as
per drawing, design and accepted by the Engineer. [Rate is excluding the cost of
painting]
sqm.
Tk.
7,991.00
19.5
Manufacturing, supplying, fitting and fixing G.I. pipe gate of any design and shape
having 38 mm dia G.I. pipe outer frame and 19 mm dia. G.I. pipe vertical member
placed @ 75 mm c/c by welding at top and bottom of G.I. pipe frame, cutting the
pipes in proper shape and size including making semicircular band at the corners of
the outer frame without damaging the pipe, covering 50% of the gate area with 18
BWG M.S. sheet, providing also two extra horizontal 38 mm dia G.I. pipes welded
with vertical post, providing 6 Nos. huskle domney with R.C.C. or R.C.C core pillar
with cement concrete (1:2:4) in masonry including cutting holes, mending the
damages, making provision for minimum 0.61 m x 1.4 m pocket gate having its outer
frame and inner vertical members made with 19 mm dia G.I. pipe including
necessary locking arrangements. Painting the gate with 2 (two) coats of synthetic
enamel paint over a coat of anti-corrosive priming, welding as and where necessary
including necessary locking arrangement and providing 2 Nos. 16 mm M.S. socket
bolts etc. all complete as per design and drawing and accepted by the Engineer.
[Rate is excluding the cost of painting]
sqm.
Tk.
9,307.00
Item No.
135
Description of Item
Unit
19.6
Supplying, fitting and fixing of rolling shutter of any design and shape made of 24
SWG G.P. sheet unit minimum 69 mm width having 10 mm and 12 mm dia circular
folding at ends, rolled in machine, locked together properly to form rolling shutter, top
of the shutter to be fitted with circular spring box made of 22 BWG sheet, containing
best quality spring made in China, nutted with 38 mm G.I. pipe at one end and the
other end nutted to shutter including fitting the G.I. pipe again with 375 x 300 x 6 mm
pankha at ends with side guide channel (side channel consist of 50 x 100 x 6 mm
M.S. plate with 2 x 19 x 3 mm F.I. bar, middle channel consist of 2 x 150 mm x 6 mm
M.S. plate with 2 x19 mm x 6 mm fixed to wall or column with clamps embedded in
R.C.C. part by cement concrete (1:2:4) including cutting holes (minimum 3 x 25 mm
x6 mm) mending the damages, finishing, curing, bottom end of shutter fitted to folded
G.P. sheet (min 125 mm width in two layers), which is again fitted to 25 x 25 x 3 mm
angle, providing handle with F.I. bar 25 x 6 mm and locking arrangement in both
sides, painting two coats with approved colour and brand of synthetic enamel paint
over a coat of priming etc. complete in all respect accepted by the Engineer. [Rate is
excluding the cost of painting]
sqm.
Tk.
5,300.00
19.7
Manufacturing, Supplying, fitting, fixing of ordinary type M.S. folding gate with
12mm x 12mm MS square solid bar and 25 mm x 25mm x 6 mm MS Angle box
frame including fabrication, welding, cost of electricity, workshop charges, carriage,
cutting grooves, mending good the damages, finishing, curing etc. including
fabrication, riveting, welding as and where necessary, etc. all complete as per
drawing, design and accepted by the Engineer.
sqm.
Tk.
4,865.00
Unit Rate
Item No.
136
Description of Item
Unit
Unit Rate
Description of Item
Unit
Rate
20.1
Manufacturing, supplying, fitting and fixing stair railing of any standard height of any
design and shape with square box (2 Nos. in each tread) made by thorough
welding of 2 Nos. 19 x 19 x 3 mm M.S. angle to provide hand-rail, engraving each
box 150 mm in the concrete by 50 x 50 x 6 mm anchor plate at base welding 38 mm
x 6 mm F.I. bar inclined plain with the top of the box to fit in the grooved wooden rail
by necessary screws including cutting grooves in concrete, mending good the
damages with cement concrete (1:2:4), applying first class polish to hand rail, 2 (two)
coats of synthetic enamel paint of approved quality over a prime coat etc. finished in
all respect for all floors and accepted by the Engineer.(Exposed area of railing will be
considered for measurement, rate is excluding cost of hand-rail and cost of painting).
sqm
Tk.
3,273.00
20.2
Manufacturing, supplying, fitting and fixing stair railing of standard height of any
design and shape with square box (2 No. box in each tread) made by thorough
welding of 2 Nos. 25 x 25 x 5 mm M.S. angle, engraving each box 150 mm in the
concrete by 50 x 50 x 6 mm anchor plate at base welding 50 x 50 x 6 mm F.I. bar in
inclined plain with the top of the box fit in the grooved wooden rail and 2 Nos. 225 x
25 mm finished section of wooden strip fitted and fixed at mid height of railing at both
side of M.S. angle box in inclined plain parallel to the hand rail etc. fitted and fixed by
necessary screws, nails including cutting grooves in concrete mending good the
damages with cement concrete (1:2:4) applying 1st class French polish to wooden
hand rail and inclined wooden strip and painting to F.I bar and square box with 2
(two) coats of synthetic enamel paint of approved quality and colour over a prime
coat etc. complete in all respect for all floors and accepted by the Engineer.
(Exposed area of railing will be considered for measurement, rate is excluding cost of
polishing and painting)
sqm
Tk.
6,471.00
20.3
Supplying, fitting and fixing 12 mm dia G.I pipe stair railing of any standard height
of any design and shape with 50 x 50 x 6 mm M.S. plate at the base of 12 mm dia
G.I. Pipe and fitted and fixed by welding. Placing the pipes vertically @ 125 mm c/c
(1 Nos. in each steps) 150 mm embedded into the R.C.C tread of stair case after
cutting grooves and mending good the damages with C.C. and providing 38 x 6 mm
F.I. bar on the top of G.I. pipe to provide wooden/G.I. pipe hand rail of any design
including polishing painting etc. all complete and accepted by the Engineer.
(Exposed area of railing will be considered for measurement, rate is excluding the
cost of pain, wood for railing)
20.3.1
sqm
Tk.
1,932.00
20.3.2
sqm
Tk.
2,479.00
20.4
Supplying, fitting and fixing stainless steel (SS) stair railing of standard height with
2 mm thick 2.5 dia pipe for hand-rail as per drawing and accepted by the Engineer.
sqm
Tk.
7,008.00
20.5.1
Supplying, fitting and fixing 12 mm dia G.I pipe stair railing of any standard height
of any design and shape with 50 x 50 x 6 mm M.S. plate at the base of 12 mm dia
G.I. Pipe and fitted and fixed by welding. Placing the pipes vertically @ 125 mm c/c
(1 Nos. in each steps) 150 mm embedded into the R.C.C tread of stair case after
cutting grooves and mending good the damages with C.C. and providing 38 x 6 mm
F.I. bar on the top of G.I. pipe to provide wooden/G.I. pipe hand rail of any design
including polishing painting etc. all complete and accepted by the Engineer.(Exposed
area of railing will be considered for measurement, rate is excluding the cost of pain,
wood for railing)
sqm
Tk.
3,467.00
Item No.
137
Description of Item
Unit
Unit Rate
20.5.2
sqm
Tk.
3,972.00
20.6
Supplying, fitting and fixing verandah railing with 2mm thick 50 mm, 25 mm and 20
mm diameter stainless steel pipes as per approved design and accepted by the
Engineer.
sqm
Tk.
11,391.00
20.7
20.7.1
Providing 1.5" x 1.5" x 1/4" M.S. angle to the nosing of steps of staircase
rm
Tk.
376.00
20.7.2
Providing nosing 1.25" x 1.25" x 1/4" M.S. angle to the nosing of steps of stair case.
rm
Tk.
325.00
20.7.3
Providing 1" x 1" x 1/4" size M.S. angle to the nosing of stair case.
rm
Tk.
276.00
20.7.4
Providing 1.5" x 1.5" x 1/4" brass angle to the nosing of steps of stair case
rm
Tk.
1,206.00
Item No.
138
Description of Item
Unit
Unit Rate
Description of Item
Unit
Rate
21.1
Supplying, fitting and fixing steel grill fencing in boundary wall of any design and
shape with 31 x 6 mm F.I. bar @ 150 mm c/c placed vertically after cutting as per
required measurement. Welding the said F.I. bar with 2 Nos. horizontal 30 x 6 mm
F.I. bar placed one at top and another at bottom including embedding/fixing the
horizontal F.I. bar in position including cutting grooves in wall up to 150 mm depth
and mending good the damages with C.C. (1:2:4) finished with two coats of painting
with synthetic enamel paint over a coat of anti-corrosive paint etc. complete as per
drawing and design and accepted by the Engineer. (Rate is excluding the cost of
painting)
sqm
Tk.
1,929.00
21.2
Supplying, fitting and fixing steel grill fencing of any design and shape made with
19 mm x 3 mm tube (angle box made with 2 Nos.19 x 19 x 3 mm angle in by
continuous welding) placed vertically @ 150 mm c/c and welding the said vertical
boxes with two Nos. horizontal 25 x 25 x 6 mm angle box (made with 2 Nos. 25 x 25
x 6 mm angle by welding), placing one at bottom and another at top and again fitted
and fixed by welding the said horizontal tube box (with vertical 38 x 38 x 6 mm angle
box post made with 2 Nos. 38 x 38 x 6 mm angle by welding) provided 1800 mm c/c
including embedding the tube box post in brick R.C.C. pillar or core wall up to 375
mm depth after cutting grooves in wall/pillar including mending good the damages
with C.C. (1:2:4) and finishing, curing, 2 coats of approved synthetic enamel paint
over a coat anti-corrosive paint etc. all complete as per design, drawing and
accepted by the Engineer.(Rate is excluding the cost of painting)
sqm
Tk.
4,470.00
21.3
Manufacturing, supplying, fitting and fixing M.S. grill fencing as per design with
outer frames having 38 x 38 x 6 mm M.S. angle and inner members having 6 mm dia
M.S. rod placed @ 110 mm c/c diagonally on both direction, welding each cris-cross
end of rod with corners of outer frame including cutting rods and size angles to
required shapes and size and setting the entire fence with the previously installed
tube (angle box) post including thorough and full welding the frame with the angle
box posts, painting 2 coats of synthetic enamel paint over a coat of anti-corrosive
priming etc. all complete as per drawing and accepted by the Engineer.
(Rate is excluding the cost of angle box post and its installation and excluding the
cost of paint)
sqm
Tk.
2,238.00
21.4
Manufacturing, supplying, fitting and fixing M.S. tube (angle box) post (bottom end
bifurcated) made by thorough welding of two Nos. 38 x 38 x 6 mm M.S. angle and
vertically placing the post into C.C. or R.C.C. foundation including cutting angle to
required shape and size including covering the top of the post with 6 mm thick M.S.
plate etc. all complete as per drawing. (Rate is excluding the cost of C.C./R.C.C.
foundation and paint)
sqm
Tk.
932.00
21.5
Providing barbed wire fencing with R.C.C (1:2:4) pillars @ 2.43 m c/c. and of
section 100 mm x 100 mm at top and 150 mm x 150 mm at bottom of 2.13 m total
height (1.37 m above G.L. and 0.76 m below G.L.) including 150 mm thick, 450 mm
square spread footings (pillars reinforced with 4 Nos. 10 mm dia main rod and 6 mm
dia stirrups @ 150 mm c/c, footing reinforced with 5 Nos. 10 mm dia rod both ways)
supplying, fitting and fixing 8 lines of barbed wire horizontally (fixed with the post
through 6 mm dia, rods embedded in to the post) and 2 lines diagonally from post to
post with 12 BWG 2 ply barbed wire, with 4 points barbs @ at least 112 mm c/c
including 6 mm thick (1:4) cement plaster up to 1500 mm length of the pillars etc.
complete and accepted by the Engineer. (Rate is excluding the cost of concrete and
reinforcement which is to be paid as per corresponding items in the schedule)
sqm
Tk.
139.00
Item No.
139
Description of Item
Unit
21.6
Providing barbed wire fencing with average 100 mm dia best quality local bullah
post of 1.98 m total height (1.37 m above G.L. and min. 0.60 m embedded in the
ground) placed at 1800 mm c/c with 9 Nos. horizontal lines and 2 Nos. diagonal lines
of 12 BWG 2 ply barbed wire with 4 points barbs @ at least 112 mm c/c in each way
of 1.8 m including embedded the post tightly in ground and providing a cement
concrete base of 200 x 200 x 300 mm around ballah at E.G.L, stretching the wires
and fixing with the post with the help of minimum 62 mm long G.I. nails including
supply of all materials etc. all complete and accepted by the Engineer.(Rate is
excluding the cost of ballah and its driving/fixing and concrete which is to be paid as
per corresponding items in the schedule)
sqm
Tk.
240.00
21.7
Supplying, fitting and fixing 12 BWG barbed wire (2 ply, 4 points) in fencing work
@ 150 mm c/c in both horizontally and vertically, supported by 38 x 38 x 6 mm
M.S. angle post (300 mm embedded in R.C.C. or in brick work with a cement
concrete base of 75 x 75 x 300 mm) 600 mm vertical and 450 mm inclined or as per
requirement @ 2.4 m c/c including straightening, binding the joints with 18 BWG wire
making holes in the angle etc. in /c supplying of all necessary materials complete in
all respect and accepted by the Engineer. (Rate is excluding the cost of R.C.C or
brick work or C.C. which is to be paid as per corresponding items in the schedule)
sqm
Tk.
760.00
Unit Rate
Item No.
140
Description of Item
Unit
Unit Rate
Description of Item
Unit
Rate
22.1
rm
Tk.
54.00
22.2
Supplying, fitting and fixing of 20mm dia foreign made aluminium pipe curtain rail
for door and window including cutting and fitting fixing as per required measurement
and supplying necessary screws, electric drill and rowel plug including charge of
electricity etc. complete and accepted by the Engineer.
rm
Tk.
552.00
22.3
Supplying, fitting and fixing 10mm thick clear tempered glass door including all
accessories 1 set maintenance auto closed special quality 2 nos clamping device, 1
set locking device, top hinge and handle etc. complete in all respect as per drawing
and direction of the Engineer in Charge.
sqm
Tk.
13,075.00
22.4
Supplying, fitting and fixing 10mm thick clear glass partition with 44mm, 44mm,
1.5mm aluminium box, protector bit (single), protector bit (double) in/c all accessories
etc. all complete and as per drawing and direction of the Engineer in Charge.
sqm
Tk.
3,238.00
22.5
Supplying, fitting and fixing of C.T wood strip (62 x 25 x 20 mm) for fixing of
aluminium curtain rails as per design and drawing fitted and fixed in position
including supply of screws, nails, drilling etc. and two coats of French polishing over
a coat of priming etc. all complete and accepted by the Engineer. (Rate is excluding
the cost of polishing and painting etc.)
rm
Tk.
646.00
22.6
Supplying, fitting and fixing vertical Venetian blinds made with glass fiber fabrics
(foreign made) with supply of all materials (foreign made) such as Head rail
(Aluminium), end cap-set, rod till, sigger (stopper) runner, spacer (link), Handling
cord, ball chain, link chair, cord-weight weight-plate plastic washer, glass fiber
fabrics, and head cap-set etc. all complete and accepted by the Engineer.
sqm
Tk.
1,655.00
22.7
Supplying, fitting and fixing horizontal Venetian blinds 1" width made with
aluminium foils/ strips (foreign made) with supply of all materials (foreign made) such
as head rail, bottom rail, rod till, head cap, bottom cap, gear box, stick, support and
cap, cord drum and support, bracket, cord lock, cord equalizer, top holder, ladder,
cord, handling cord and aluminium foils etc. all complete and accepted by the
Engineer.
sqm
Tk.
1,270.00
22.8
Supplying, fitting, fixing of steel iron rack made of 50 x 50 x 6.35 mm vertical and
horizontal angle post, welding 63.5 mm x 6.35 mm F.I. bar placed horizontally as
bracing for the posts, 38 x 6.35 mm cross F.I. bars welded with vertical post, 12.7
mm thick M.S plate welded as cup shape at the bottom of post, supplying and fitting
rivets, charge for wielding, drilling, carrying, cutting, straightening, in required sizes
etc in all respect as per drawing, design and accepted by the Engineer.
sqm
Tk.
9,334.00
Item No.
141
Description of Item
Unit
Unit Rate
22.9
Supplying fitting, fixing of uPVC plastic door or window frame having specific
gravity 1.35 - 1.45, and other physical, chemical, thermal, fire resistivity properties
etc. as per BSTI approved manufacturer standards or ASTM, BS/ISO/IS standards
fitted and fixed in brick wall/ R.C.C wall with 6 Nos. GI clamp, 4Nos inner joint GI
clamp, 2 Nos. outer GI joint clamp, 16 Nos. rivet making necessary grooves and
mending good the damages, finishing, curing, carriage etc complete in all respect
accepted by the Engineer.
rm
Tk.
248.00
22.10
Supplying, fitting, fixing of uPVC hollow or solid plastic door shutter having
specific gravity 1.35 - 1.45, thickness 1.7 mm-2.2 mm, and other physical, chemical,
thermal, fire resistivity properties etc. as per BSTI approved manufacturer standards
or ASTM, BS/ISO/IS standards of different sizes fitted fixed with uPVC plastic door
frame weighing 5.82 kg/m2 with at least 3 Nos. SS hinges by min 64 Nos. 3.17 mm
and 3.97 mm 12.7 mm long rivets, 12 Nos. 25.4 mm SS screws, 9.38 mm, 150
mm long SS tower bolts 2 Nos., 146 mm SS handle by rivet 2 Nos., G.I inner joint
234.95 mm x 127 mm clamp, 76.2 mm x 57.15 mm, 25 mm dia 1 no SS haspbolt,
special type round lock, carrying the same to the site and local carriage etc.
complete in all respect accepted by the Engineer
22.10.1
each
Tk.
3,259.00
22.10.2
each
Tk.
3,369.00
22.10.3
each
Tk.
3,557.00
22.10.4
each
Tk.
3,683.00
22.11
Supplying, fitting, fixing uPVC plastic or glass partition in plastic frame fabricated
by 70 x 50 x 2 mm T and 50 x 40 x 2 mm / 50 x 30 x 2 mm L-sections, providing
partition with 156 x 25 mm uPVC hollow section having wall thickness 2.5 mm /
partition with 5 mm thick glass. Physical, chemical, thermal, fire resistivity properties
etc of the materials as per BSTI approved manufacturer standards or ASTM,
BS/ISO/IS standards, fitted and fixed in brick wall or R.C.C wall with 6 Nos. GI
clamp, 4 Nos. inner joint GI clamp, 2 Nos. outer GI joint clamp, 16 Nos. rivet making
necessary grooves and mending good the damages, finishing, curing, carriage etc
complete in all respect and accepted by the Engineer.
22.11.1
each
Tk.
2,419.00
22.11.2
With 5 mm glass
each
Tk.
2,431.00
22.12
Supplying, fitting, fixing of uPVC Profile for door, window and fixed partition
frames applications having specific gravity 1.36-1.43, and other physical, chemical,
thermal, fire resistivity properties etc. as per BSTI approved manufacturer standards
or ASTM, BS/ISO/IS standards including all accessories fittings with 6 Nos. steel
clamps complete in all respect as per drawing and accepted by the Engineer.
rm
Tk.
439.00
22.13
Supplying, fitting, fixing swing door shutter made of low density free foam (LDFF)
sheet having standard size 4' x 8'. Physical properties: density: 0.55-0.68 g/cm3,
weighing 1.3 kg/sft, providing new sash (4"), sliding glass bead, rubber, screws, 3"
hinges 4 Nos., 4" tower bolt 2 Nos., 6" handle 2 Nos. etc. including all accessories
complete in all respect as per drawing and accepted by the Engineer.
22.13.1
each
Tk.
8,762.00
22.13.2
each
Tk.
9,027.00
Item No.
142
Description of Item
Unit
22.13.3
each
Tk.
9,293.00
22.14
Supplying fitting fixing of plastic wall paneling with 3 mm sheet, weighing 0.188
kg/sft fitted and mending good the damages, carriage to the site including glass
bead, partition frame, rubber, 5 mm clear glass fitted and fixed with screws, steel
clamp accepted by the Engineer.
sqm
Tk.
1,119.00
22.15
Supplying, fitting, fixing of uPVC Profile fixed partition with 5 mm clear glass,
weighing 1.032 kg/sft fitted and mending good the damages, carriage etc. complete
in all respect accepted by the Engineer
sqm
Tk.
3,129.00
22.16
Supplying, fitting, fixing of uPVC profile sliding window having gross weighing 1.3
kg/sft (including glass) fitted and mending good the damages, carries etc complete in
all respect accepted by the Engineer.
22.16.1
sqm
Tk.
4,374.00
22.16.2
sqm
Tk.
3,388.00
22.17
Supplying, fitting, fixing of plastic wood paneling in false ceiling with 6 mm sheet,
weighing 0.358 kg/sft fitted and mending good the damages, carries etc complete in
all respect accepted by the Engineer
sqm
Tk.
1,147.00
22.18
Supplying, fitting and fixing approved quality 190 mm x 190 mm size glass bricks in
round stair wall complete in all respect and accepted by the Engineer.
sqm
Tk.
13,740.00
22.19
Supplying, and fitting and fixing 50 mm thick rock or glass wool padding of
approved quality and accepted by the Engineer.
sqm
Tk.
3,509.00
Unit Rate
Item No.
143
Description of Item
Unit
Unit Rate
Unit
Rate
Description of Item
23.1
23.1.1
cum
Tk.
142.00
23.1.2
cum
Tk.
5.30
23.1.3
cum
Tk.
7.77
23.1.4
cum
Tk.
10.24
23.1.5
Extra each additional lead of 0.3 m or part there of beyond initial lead 30 meter
cum
Tk.
20.84
23.2.1
Bailing out water by 1 cusec diesel operated pump including hire charge of
pump, fuel, operator, spares and maintenance etc. complete.
Per hour
Tk.
458.00
23.2.2
Bailing out water by 1 cusec electricity operated pump including hire charge of
pump, fuel, operator, spares and maintenance etc. complete
Per hour
Tk.
373.00
Item No.
144
Description of Item
Unit
Unit Rate
Unit
Rate
Description of Item
24.1
Earth work in road embankment up to a lift of 1.5 m in all kinds of soil including
cutting and throwing earth in layers not exceeding 150 mm in thickness, breaking
clods up to 40 mm size in each layer, ramming, leveling and dressing as per required
side slope and alignment with earth borrowed from the road side Govt. acquired land
for any leads and maintaining the embankment true to level and side slopes as per
profiles for one year from the date of completion including making dug, bailing,
profiling etc. complete and accepted by the Engineer.
24.1.1
cum
Tk.
111.00
24.1.2
cum
Tk.
126.00
24.1.3
cum
Tk.
142.00
24.1.4
cum
Tk.
158.00
24.1.5
cum
Tk.
173.00
24.1.6
cum
Tk.
189.00
24.2
Earthwork in box cutting in all types of soil. Removing soil to a safe distance,
maintaining proper alignment, camber and grade including leveling, dressing and
compacting the sub grade as per drawing and accepted by the Engineer
24.2.1
sqm
Tk.
38.00
24.2.2
sqm
Tk.
54.00
24.3
Creating turf on the side slopes and top of embankment with good quality turf not
less than 225 mm square chunk, watering till the grass grown including all leads and
lifts etc. complete and accepted by the Engineer.
sqm
Tk.
13.00
24.4
Single layer brick flat soling in road work with first class or picked jhama bricks as
per alignment, camber and grade including filling joints with sand (F.M. 0.50) etc.
complete including cost of all materials and accepted by the Engineer.
sqm
Tk.
368.00
24.5
Brick on edges pavement in herring bone bond (HBB) with first class or picked
jhama bricks as per alignment, camber and grade over 12 mm thick sand cushion
(F.M. 0.50) including filling the joints with the same sand including cost of all
materials and accepted by the Engineer.
sqm
Tk.
601.00
24.6
Double brick flat soling in roadwork with first class or picked jhama bricks as per
camber and grade and filling the joints with fine sand (F.M. 0.50) and also providing
12 mm thick sand cushion in between the two layers of brick flat soling with the same
quality of sand including cost of all materials and accepted by the Engineer.
sqm
Tk.
744.00
24.7
Brick on end edging (75 mm across the road) with first class or picked jhama bricks
and filling the gaps with fine sand (F.M. 0.50) including cutting trenches, true to level
and grade, removing earth, refilling and ramming the sides properly including cost of
all materials and accepted by the Engineer.
rm
Tk.
93.00
Item No.
145
Description of Item
Unit
Unit Rate
24.8
Breaking picked jhama, first class bricks or bats including cost of bricks and bats
and stacking in measurable sizes at site accepted by the Engineer
24.8.1
cum
Tk.
3,068.00
24.8.2
cum
Tk.
3,172.00
24.9
Labour for compacted water bound Macadam base course with graded metal of
crushed well burnt, picked jhama or first class bricks and bats having compacted
thickness made as per specifications including local handling and spreading
uniformly to proper grade, camber and super elevation, hand packing, rolling
properly with 8 to 10 ton capacity power driven Road Roller and watering profusely
for compaction of 100% MDD (standard) blinding with sand (F.M. 0.80) @ 12 m3 per
m2 including fuel, lubricants, spares, maintenance, driver etc. all complete and
accepted by the Engineer.
cum
Tk.
613.00
24.10
Providing compacted sub-base base course with well graded metal of crushed well
burnt p.j. / 1st class brick bats and sand (FM 0.8) with mixing proportion 2 : 1 having
compacted thickness made as per specification including local handling, spreading
uniformly to proper grade camber and super elevation, packing rolling properly with 8
to 10 ton capacity power driven road roller and watering properly for compaction of
100% MDD (standard) blinding with sand including cost of fuel, lubricants, spares,
maintenance, driver etc. all complete and accepted by the Engineer in charge.
cum
Tk.
3,379.00
24.11
sqm
Tk.
1,046.00
24.12
sqm
Tk.
858.00
24.13
sqm
Tk.
626.00
Item No.
146
Description of Item
Unit
Unit Rate
24.14
sqm
Tk.
885.00
24.15
sqm
Tk.
737.00
24.16
sqm
Tk.
495.00
24.17
Providing tack coat @ 7.32 kg of bitumen per 10 sqm including heating bitumen up
to 1760C to 1880C and spreading etc. all complete (cost of bitumen included)
accepted by the Engineer.
sqm
Tk.
87.00
24.18
Providing seal coat with 4 cft of Sylhet sand (FM 2.2) mixed with @ 7.32 kg of
bitumen per 10 sqm of road surface including supplying and spreading of 0.09 cum
of sand (F.M. 0.80) including heating bitumen up to 176 degree to 190 degree
Celsius and spreading etc. all complete (cost of bitumen included) accepted by the
Engineer.
sqm
Tk.
186.00
24.19
Premixed bituminous seal coat with 0.12 cum of pea gravels mixed with 80 kg of
bitumen per cum of pea gravels and laid over 10 sqm, road surface, spreading with
proper camber, grade, surface blinding with dry sand (F.M. 2.5) @ 0.09 cum per 10
sqm, rolling the suface with min 8 ton power driven roller etc. all complete and
accepted by the Engineer.
sqm
Tk.
235.00
24.20
Providing bitumenous painting with 4.54 kg of bitumin per 10 sqm. of road surface
including supplying and spreading of 0.09 cum of sand (FM 1.20) with heating
bitumen upto 176 degree to 196 degree celsius, surface rolling with min 8 ton power
driven roller etc. all complete and accepted by the Engineer.
sqm
Tk.
104.00
24.21
Providing painting top of the road surface as road marking in two coats with
approved best quality and colour of synthetic approved quality of paint from
authorized local agent of the manufacturer in a sealed container having highly water
resistant, high bondability, flexible, using specific brand thinner applied by brass/
roller or others over a coat of priming elapsing time for drying including surface
cleaning from dust, oil or dirt, smoothening, finishing necessary tools etc. all
complete in approved and accepted by the Engineer.
sqm
Tk.
223.00
Item No.
24.22
147
Description of Item
Unit
Providing expansion joints across the R.C.C. road pavement with 20 mm gap
between the adjacent panels. Supplying dowel bars of size 12 mm dia 600 mm long
M.S rod placed at 750 mm c/c. 300 mm of the bar fixed within one slab keeping
remaining portion the bar free within the adjacent slab being inserted in 20 mm dia
300 mm long P.V.C. pipe embedded in the slab, inside of pipe fully greased, filling
the gap between the slabs (with admixture) of hot bitumen and coarse sand (F.M.
2.5) in proportion (2:1) finishing the top with bitumen, spreading coarse sand over the
joint, all complete as per plan, drawing and accepted by the Engineer.
rm
Unit Rate
Tk.
317.00
Item No.
148
Description of Item
Unit
Unit Rate
Description of Item
Unit
Rate
25.1
Labour charge for scraping lawn surface up to 38 mm thick by spade, picking up all
sorts of bricks bats, rubbish by suitable tools, removing the same by head load or by
any other means and stacking the same to a safe distance beyond 300 m including
supply of tools and plants etc. all complete and accepted by the Engineer.
sqm
Tk.
7.10
25.2
sqm
Tk.
15.00
25.3
Leveling and dressing of lawn area to proper slope and grade by spading the
same up to 150 mm including supplying tools and plants etc. all complete and
accepted by the Engineer.
sqm
Tk.
4.70
25.4
Supplying of best and approved quality alluvial loamy silty soil including loading,
unloading at both ends, properly stacking at site including supply of tools and plants
etc. all complete and accepted by the Engineer.
cum
Tk.
567.00
25.5
Supplying well decomposed cow dung carried by trucks or any other means
including loading, unloading at both ends, stacking the same at site including supply
of tools and plants etc. all complete and accepted by the Engineer.
cum
Tk.
1,183.00
25.6
Labour charge for spreading the alluvial loamy silty soil from the stacks at site on
the lawn surface, leveling, dressing the same including supply all necessary tools
and plants etc. all complete and accepted by the Engineer.
cum
Tk.
115.00
25.7
Supplying lawn grass of approved quality by truck or any other means, sorting the
grass to proper size, washing the grass, dibbling the grass 6 mm to 50 mm apart,
irrigation of lawn area till the grass grown at least for two months after plantation,
weeding the undesirable grass, mowing the lawn grass by lawn mower up to two
months after plantation, applying urea fertilizer on the lawn surface @ 1 kg per 9.29
sqm including supply of tools and plants etc. all complete and accepted by the
Engineer.
sqm
Tk.
41.00
25.8
Labour charge for mixing well decomposed cow dung with alluvial loamy silty
soil and excavated earth, removing the excess earth to safe distance including
supply of tools and plants etc. all complete and accepted by the Engineer.
cum
Tk.
107.00
25.9
Supplying and providing, fitting, fixing bamboo jafry fencing by best quality muli
bamboo split 20mm in width, having 75 mm x 75 mm mesh placed horizontally and
diagonally doing 25 mm framing a square shape in both ways and both sides
tightened with G.I wire fitted with Borrak bamboo post of 100 mm dia and placed
firmly in position at 1800 mm apart including supply of tools and plants, digging hole
and filling back etc. all complete and accepted by the Engineer.
sqm
Tk.
364.00
Item No.
149
Description of Item
Unit
25.10
Supplying and providing, fitting, fixing muli bamboo tree guard 1200 mm long and
500 mm dia fixing with best quality muli bamboo split 20 mm in size having 75 mm x
75 mm a square holes with 20 mm wide bamboo splits strengthen with 4 Nos. 20 mm
wide bamboo split in both sides tightened with G.I wire fitted with 3 Nos. 63 mm dia
borrak bamboo post of 1800 mm long of which 600 mm will be driven into earth by
digging hole followed by fill back including supply of tools and plants all complete as
per direction of engineer-in-charge.
each
Tk.
481.00
25.11
Earth work in excavation to make a pit of 600 x 600 x 450 mm (depth) for
plantation, applying cow dung mixing with loamy silty soil and excavated earth,
planting the plants, tightened with 1800 mm long borrak bamboo post with jute rope
including supply of tools and plants all complete and accepted by the Engineer.
each
Tk.
110.00
25.12
sqm
Tk.
364.00
25.13
sqm
Tk.
183.00
25.14
Carrying of rubbish, taking up all sorts of bricks, brick-bats and rubbish gravel
chips, loading and unloading at both ends including supply of tools and plants etc. all
complete and accepted by the Engineer.
cum
Tk.
111.00
25.15
Supply and carrying of 12.20 m long 100 mm dia borrak bamboo at site, loading
and unloading at both end stacking the same at site including supply of tools and
plants etc. all complete and accepted by the Engineer.
each
Tk.
378.00
25.16
Supply and carrying of 7.62 m long 50 mm to 62.5 mm dia muli bamboo at site,
loading and unloading at both end stacking the same at site including supply of tools
and plants etc. all complete and accepted by the Engineer.
each
Tk.
171.00
Unit Rate
Item No.
150
Description of Item
Unit
Unit Rate
Unit
Rate
Description of Item
26.1
Supplying, fitting and fixing European type glazed porcelain commode "S" type
465 x 340 x 415 mm in size, approximately 14 kg by weight, plastic seat cover and
preparing the base with cement concrete and with wire mesh or rods, if necessary, in
all floors including making holes wherever required and mending good the damages
and fitting, fixing finishing etc. complete with all necessary fittings and connection
approved and accepted by the Engineer.
26.1.1
Standard
26.1.1.1
BISF White
each
Tk.
3,091.00
26.1.1.2
BISF Coloured
each
Tk.
3,175.00
26.1.1.3
each
Tk.
3,259.00
26.2
Supplying, fitting and fixing European type glazed porcelain low-down, capacity 10
liter, 490 x 190 x 350 mm in size, approximately 14 kg by weight, on walls by screws
and F.I. bar clamps, rowel plugs, making holes wherever required and mending good
the damages and fitting, fixing finishing etc. complete with all necessary fittings and
connection approved and accepted by the Engineer.
26.2.1
Standard
26.2.1.1
BISF White
each
Tk.
2,096.00
26.2.1.2
BISF Coloured
each
Tk.
2,468.00
26.2.1.3
each
Tk.
2,840.00
26.3
Supplying, fitting and fixing European type glazed porcelain Combi closet, in/c
plastic seat cover, cystern system, preparing the base with cement concrete and with
wire mesh or rods if necessary, in all floors including making holes wherever required
and mending good the damages and fitting, fixing, finishing etc. complete with all
necessary fittings and connection approved and accepted by the Engineer.
26.3.1
Standard
26.3.1.1
each
Tk.
7,242.00
26.3.1.2
each
Tk.
7,242.00
26.3.1.3
BISF Special coloured Item No. 115A/415A, 700 x 410 x 795 mm,31.5kg
each
Tk.
8,679.00
26.3.2
Super
26.3.2.1
each
Tk.
10,698.20
26.3.2.2
each
Tk.
13,907.66
26.3.2.3
each
Tk.
16,047.30
Item No.
151
Description of Item
Unit
Unit Rate
26.3.3
Superior
26.3.3.1
White , 700x360x785,36(+/-)36.5kg
each
Tk.
15,502.00
26.3.3.2
Coloured 700x360x785,36(+/-)36.5kg
each
Tk.
20,152.60
26.3.3.3
each
Tk.
30,228.90
26.4
26.4.1
White
each
Tk.
21,353.00
26.4.2
Coloured
each
Tk.
27,869.00
26.4.3
Special coloured
each
Tk.
30,661.00
26.5
Supplying, fitting and fixing Bangladesh pattern, long pan with foot-rest, made of
Vitreous China and preparing the base of pan with cement mortar (1:4) and with wire
mesh or rods, if necessary in all floors including making holes wherever required and
mending good the damages and fitting, fixing, finishing etc. complete with all
necessary fittings and connection approved and accepted by the Engineer.
26.5.1
Standard
26.5.1.1
each
Tk.
1,902.00
26.5.1.2
each
Tk.
1,971.00
26.5.1.3
each
Tk.
2,044.00
26.5.2
Super
26.5.2.1
each
Tk.
2,190.00
26.5.2.2
each
Tk.
2,607.00
26.5.2.3
each
Tk.
3,023.00
26.6
Supplying, fitting and fixing Bangladesh pattern long pan, made of Vitreous China
and preparing the base of pan with cement concrete and with wire mesh or rods if
necessary in all floors including making holes wherever required and mending good
the damages and fitting, fixing, finishing etc. complete with all necessary fittings and
connection approved and accepted by the Engineer.
26.6.1
Standard
26.6.1.1
each
Tk.
1,106.00
Item No.
152
Description of Item
Unit
Unit Rate
26.6.2
Coloure
omitted
each
26.6.3
Special coloured
omitted
each
26.7
Supplying, fitting and fixing plastic low-down including all fittings and accessories
each
Tk.
2,017.00
26.8
each
Tk.
174.00
26.9
Supplying, fitting and fixing white glazed vitreous W/H Wash Basin including
excluding pedastal, fitting, fixing the same in position with heavy type C.I. Brackets.
30 mm dia PVC waste water pipe with brass coupling (not exceeding 750 mm in
length), basin waste with chain plug including making holes in walls and floors and
fitting with wooden blocks, screws and mending good the damages, finishing etc. all
complete approved and accepted by the Engineer.
26.9.1
Standard
26.9.1.1
each
Tk.
2,372.00
26.9.1.2
each
Tk.
2,450.00
26.9.1.3
each
Tk.
2,712.00
26.9.1.4
BISF-211 White,595x430x190,10kg
each
Tk.
1,997.69
26.9.1.5
each
Tk.
2,359.03
26.9.1.6
each
Tk.
2,655.10
26.9.1.7
each
Tk.
1,937.72
26.9.1.8
each
Tk.
1,989.10
26.9.1.9
each
Tk.
2,065.29
26.9.1.10
each
Tk.
1,375.22
26.9.1.11
each
Tk.
1,410.97
26.9.1.12
each
Tk.
1,390.14
26.9.1.13
each
Tk.
1,249.07
26.9.1.14
each
Tk.
1,283.62
26.9.1.15
each
Tk.
1,261.18
26.9.1.16
each
Tk.
1,997.68
Item No.
153
Description of Item
Unit
Unit Rate
26.9.1.17
each
Tk.
2,049.75
26.9.1.18
each
Tk.
2,017.89
Cabiet Basin
26.9.1.19
each
Tk.
2,754.56
26.9.1.20
each
Tk.
2,825.99
26.9.1.21
each
Tk.
2,785.98
Corner Basin
26.9.1.22
each
Tk.
1,424.84
26.9.1.23
each
Tk.
1,712.17
26.9.1.24
each
Tk.
1,921.17
26.10
Supplying, glazed vitreous W/H Wash Basin in/c pedastal approx. size
656x510x845, 26kg by weight including fitting, fixing the same in position with heavy
type C.I. Brackets. 30 mm dia PVC waste water pipe with brass coupling (not
exceeding 750 mm in length). 12mm plastic lead (connection) pipe with brass
coupling, basin waste with chain plug including making holes in walls and floors and
fitting with wooden blocks, screws and mending good the damages, finishing etc. all
complete approved and accepted by the Engineer.
26.10.1
Superior
26.10.1
White
each
Tk.
5,798.00
26.10.2
Coloured
each
Tk.
7,240.00
26.10.3
Special coloured
each
Tk.
8,200.00
26.11
Supplying, white glazed vitreous W/H Wash Basin in/c pedastal and fitting, fixing
the same in position with heavy type C.I. brackets, 32 mm dia PVC waste water pipe
with brass coupling (not exceeding 750 mm in length), 32 mm dia C.P. basin waste
with chain plug, bracket including making holes in walls and floors and fitting with
wooden blocks, screws and mending good the damages with cement mortar (1:4),
etc. all complete approved and accepted by the Engineer.
26.11.1
Super
26.11.1.1
each
Tk.
9,642.00
26.11.1.2
each
Tk.
12,236.00
26.11.1.3
each
Tk.
13,965.00
26.12
Supplying, fitting and fixing basin pedestal, with rowel plug and screws etc. all
complete approved and accepted by the Engineer.
Item No.
154
Description of Item
Unit
Unit Rate
26.12.1
Standard
26.12.1.1
each
Tk.
1,091.00
26.12.1.2
each
Tk.
1,137.00
26.12.1.3
each
Tk.
1,186.00
26.12.2
Super
26.12.2.1
each
Tk.
2,192.00
26.12.2.2
each
Tk.
2,798.00
26.12.2.3
each
Tk.
3,201.00
26.12.3
Superior
26.12.3.1
each
Tk.
3,333.00
26.12.3.2
each
Tk.
4,281.00
26.12.3.3
each
Tk.
4,913.00
26.13
Supplying, fitting and fixing glazed vitreous standing bowl urinal, fitting, fixing the
same in position after making holes in walls and floors, providing 32 mm dia plastic
waste pipe with brass coupling up to grading below, 12 mm dia plastic connection
pipe with brass coupling, 12 mm dia brass stop cock including mending good the
damages with cement mortar (1:4) etc. all complete approved and accepted by the
Engineer.
26.13.1
Standard
26.13.1.2
each
Tk.
1,957.00
26.13.1.3
each
Tk.
2,164.00
26.13.1.4
each
Tk.
2,406.00
26.13.2
Super
26.13.2.1
each
Tk.
2,553.00
26.13.2.2
each
Tk.
3,072.00
26.13.2.3
each
Tk.
3,418.00
26.14
Supplying, fitting and fixing glazed vitreous china flat or squatting urinal
510x380x85mm in size, approx. 9.5 kg by weight with flushing inlet fitted in cement
mortar (1:4) with painted cast iron body: one gallon capacity, automatic flushing
cistern in each group etc. including 12 mm brass controlling valve, 32 mm dia PVC
flush pipe with brass coupling, 12 mm dia plastic lead (connection) pipe including
mending good the damages with 1:4 cement mortar etc. all complete approved and
accepted by the Engineer.
Item No.
155
Description of Item
Unit
Unit Rate
26.14.1
BISF -White
each
Tk.
1,495.00
26.14.2
BISF -Coloured
each
Tk.
1,549.00
26.14.3
each
Tk.
1,603.00
26.15
Supplying, fitting and fixing ,porcelain sink fitted and fixed with heavy type C.I.
brackets, 12 mm dia C.P. bib cock, 40 mm dia C.P. chain plug. 40 mm dia. C.P.
waste, 40 mm dia PVC waste pipe with brass coupling (750 mm length) including
making holes in walls and floors and mending good the damages with cement mortar
(1:4) etc. all complete approved and accepted by the Engineer.
26.15.1
each
Tk.
2,817.00
26.15.2
each
Tk.
3,524.00
26.16
Supplying, fitting and fixing single bowl stainless steel sink with sink tray size
(450 x 1050 mm.) with heavy type CI steel brackets 12mm dia C.P. bib-cock 40 mm
dia C.P. chain plug. 40 mm dia C.P. waste. 40 mm dia PVC waste pipe with brass
coupling (750 mm length) including making hole in walls and floors and mending
good the damages, finishing with 1:4 cement mortar etc. all complete approved and
accepted by the Engineer. (Malaysia / Singapore / Thailand made or equivalent)
each
Tk.
4,090.00
26.17
Supplying, fitting and fixing double bowl stainless steel sink with sink tray with
heavy type CI or steel brackets 12 mm dia C.P. chain plug. 40 mm dia C.P. waste,
40 mm dia PVC waste pipe with brass coupling (750 mm length) including making
hole in walls and floors and mending good the damages, finishing etc. all complete
approved and accepted by the Engineer. (Malaysia / Singapore / Thailand made or
equivalent)
each
Tk.
7,596.00
26.18
Supplying, fitting and fixing of 450 x 600 mm size and 5 mm thick unframed super
quality mirror with hard boards at the back with all necessary fitting including
making holes in walls and mending good the damages with cement mortar (1:4) etc.
all complete approved and accepted by the Engineer. (Made in Japan or equivalent)
each
Tk.
786.00
26.19
Supplying, fitting and fixing of 450 x 350 mm size and 5 mm thick unframed super
quality mirror with hard boards at the back with all necessary fitting including
making holes in walls and mending good the damages with cement mortar (1:4) etc.
all complete approved and accepted by the Engineer. (Made in Japan or equivalent)
each
Tk.
621.00
26.20
Supplying, fitting and fixing super quality 600 x 125 mm coloured glass (plate)
shelf having 5 mm thickness with fancy C.P. brackets, screws and frames including
making holes in walls and mending good the damages with cement mortar (1:4) etc.
all complete approved and accepted by the Engineer.
each
Tk.
1,258.00
26.21
Supplying, fitting and fixing super quality 600 x 125 mm white glass (plate) shelf
having 5 mm thickness with fancy C.P. brackets, screws and frames including
making holes in walls and mending good the damages with cement mortar (1:4) etc.
all complete approved and accepted by the Engineer.
each
Tk.
689.00
26.22
Supplying, fitting and fixing super quality C.P. Towel rail of 600 mm long and 20
mm in dia with C.P. holder including making holes in walls and mending good the
damages with cement mortar (1:4) etc. all complete approved and accepted by the
Engineer.
each
Tk.
637.00
Item No.
156
Description of Item
Unit
Unit Rate
26.23
Supplying, fitting and fixing medium quality C.P. Towel rail of 600 mm long and 20
mm in dia with C.P. holder including making holes in walls and mending good the
damages with cement mortar (1:4) etc. all complete approved and accepted by the
Engineer.
each
Tk.
537.00
26.24
Supplying, fitting and fixing standard toilet paper holder of 150 x 150 x 126 mm size
including making holes in walls and mending good the damages with cement mortar
(1:4) etc. all complete approved and accepted by the Engineer.
26.24.1
BISF white
each
Tk.
192.00
26.24.2
BISF colored
each
Tk.
227.00
26.25
Supplying, fitting and fixing of special coloured toilet paper holder Size (150 mm x
150 mm x 126 mm) including making holes in walls and mending good the damages
with cement mortar (1:4) etc. all complete approved and accepted by the Engineer.
26.25.1
each
Tk.
581.00
26.25.2
each
Tk.
743.00
26.25.2
- do - Standard size stainless steel bracket and holder rod with cover.
each
Tk.
406.00
26.25.3
each
Tk.
340.00
26.26
Supplying, fitting and fixing standard size soap tray including making holes in walls
and mending good the damages with cement mortar (1:4) etc. all complete approved
and accepted by the Engineer.
26.26.1
each
Tk.
211.00
26.26.2
each
Tk.
321.00
26.26.3
each
Tk.
375.00
26.26.4
each
Tk.
335.00
26.27
Supplying, fitting and fixing 125 mm dia stainless steel floor grating in traps or in
drains including making holes in walls/floors and mending good the damages with
cement mortar (1:4) etc. all complete approved and accepted by the Engineer.
each
Tk.
198.00
26.28
Supplying, fitting and fixing 62 mm dia stainless steel floor grating in traps or in
drains including making holes in walls/floors and mending good the damages with
cement mortar (1:4) etc. all complete approved and accepted by the Engineer.
each
Tk.
145.00
26.29
Supplying, fitting and fixing plastic grating with hinged cover size 150 x 150 mm in
traps or in drains including making holes in walls/floors and mending good the
damages with cement mortar (1:4) etc. all complete approved and accepted by the
Engineer.
each
Tk.
345.00
Item No.
157
Description of Item
Unit
Unit Rate
Supplying 100 mm inside diameter HCI rainwater down pipe, fitting and fixing in
position with head and shoes, bends, trap, tee, offset, clamps and nails etc. complete
in all floors approved and accepted by the Engineer.
rm
Tk.
1,864.00
26.31
Supplying 100 mm inside diameter best quality uPVC rain water down pipe fitting,
fixed in position with head and shoes, bends, min.20 mm width F.I. Bar clamp and
nails, and including all accessories such as round grating/domed roof grating bands,
sockets approved and accepted by the Engineer.
rm
Tk.
642.00
26.32
Supplying 50 mm inside dia HCI soil, waste and ventilation pipe each piece
having over length 1800 mm, thickness 6.5mm, spigot diameter 80 mm, weight min
12 kg fitted and fixed in position with sockets thickness min 8.5 mm, internal depth
min 68 mm, bead's outside diameter min 90 mm, ears flange length min 150 mm,
caulking clearance min 10 mm produced in foundry grade pig iron as per BSTI
approved manufacturer standard fitting and fixing in position including head and
shoes bends made of minimum 20 mm x 3 mm F.I. bar or equivalent, trap, tee,
offset, clamps and nails etc. complete in all floors approved and accepted by the
Engineer.
rm
Tk.
962.00
26.33
Supplying 100 mm inside dia HCI soil, waste and ventilation pipe each piece
having over length 1800 mm, thickness 6.5 mm, spigot diameter 117 mm, weight min
24.85 kg fitted and fixed in position with sockets thickness min 6.5 mm, internal
depth min 75 mm, bead's outside diameter min155 mm, ears flange length min 208
mm, caulking clearance min 8 mm produced in foundry grade pig iron as per BSTI
approved manufacturer standard fitting and fixing in position including head and
shoes bends made of minimum 20 mm x 3 mm F.I. bar or equivalent, trap, tee,
offset, clamps and nails etc. complete in all floors accepted by the Engineer.
rm
Tk.
1,813.00
26.34
Supplying 150 mm inside dia HCI soil, waste and ventilation pipe each piece
having over length 1800 mm, thickness 6.5mm, spigot diameter 117mm, weight min
41kg fitted and fixed in position with sockets thickness min 7mm, internal depth min
100 mm bead's outside diameter min 200mm, ears flange length min 258 mm,
caulking clearance min 9 mm produced in foundry grade pig iron fitting and fixing in
position including head and shoes, bends, trap, tee, off-set, clamps and nails etc.
complete in all floors approved and accepted by the Engineer.
rm
Tk.
2,640.00
26.35
Supplying 50 mm inside dia best quality uPVC soil, waste and ventilation pipe
having specific gravity 1.35 - 1.45, wall thickness 2.5 - 3.0 mm, and other physical,
chemical, thermal, fire resistivity properties etc. as per BSTI approved manufacturer
standards or ASTM, BS/ISO/IS standards fitted and fixed in position with sockets,
bends, of uPVC Pipe with all accessories such as Round grating /domed roof grating
bands, sockets etc. approved and accepted by the Engineer (length: 6000 mm
each).
rm
Tk.
446.00
26.36
Supplying 100 mm inside dia best quality uPVC soil, waste and ventilation pipe
having specific gravity 1.35-1.45, wall thickness 3.4- 4.0 mm, and other physical,
chemical, thermal, fire resistivity properties etc. as per BSTI approved manufacturer
standards or ASTM, BS/ISO/IS standards fitted and fixed in position with sockets,
bends, with all accessories such as Round grating/domed roof grating bands,
sockets etc. approved and accepted by the Engineer (length: 6000 mm each).
rm
Tk.
739.00
Item No.
158
Description of Item
Unit
Unit Rate
26.37
Supplying 150 mm inside dia best quality uPVC soil, waste and ventilation pipe
having specific gravity 1.35 - 1.45, wall thickness 4.5 mm - 5.2 mm, and other
physical, chemical, thermal, fire resistivity properties etc. as per BSTI approved
manufacturer standards or ASTM, BS/ISO/IS standards fitted and fixed in position
with sockets, bends, with all accessories such as Round grating/domed roof grating
bands, sockets etc. approved and accepted by the Engineer (length: 6000 mm
each).
rm
Tk.
1,073.00
26.38
Supplying, fitting and fixing G.I. pipe conforming to the standard BS-1387 & BDS1031, having chemical composition (in%) Carbon 0.17-0.25, Manganese 0.95-1.20,
Sulphur 0.060 max, Phosphorous 0.060 max, Tensile properties : miminum Yield
Strength 188 MPa, minimum Tensile Strength 313 MPa and marking for a)
Manufacturer b) Material c) Wall thickness d) Nominal outside dia e) Intended
use etc. on the body of the pipe with all special fittings, such as bends, elbows,
sockets, reducing sockets, tee, unions, jam-nuts etc. including cutting trenches
where necessary and fitting the same with earth duly rammed and fixing in walls with
holder bats and making hole in floors, walls and consequent mending good the
damages etc. all complete in all respects approved and accepted by the Engineer.
(Pipes manufactured by National Tubes Limited under Steel & Engineeing Corporation,
Ministry of Industries, Government of Bangladesh shall be given priority)
26.38.1
15 mm dia G.I. pipe with wall thickness 2.65 mm, outside diameter min 21 mm,
weight 1.31 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
rm
Tk.
301.00
26.38.2
20 mm dia G.I. Pipe with wall thickness 2.65 mm, outside diameter min 26.5 mm,
weight 1.70 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
rm
Tk.
390.00
26.38.3
25 mm dia G.I. Pipe with wall thickness 3.25 mm, outside diameter min 33.3 mm,
weight 2.59 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
rm
Tk.
508.00
26.38.4
32 mm dia G.I. Pipe with wall thickness 3.25 mm, outside diameter min 42 mm,
weight 3.33 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
rm
Tk.
644.00
26.38.5
40 mm dia G.I. Pipe with wall thickness 3.25 mm, outside diameter min 47.9 mm,
weight 3.83 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
rm
Tk.
869.00
26.38.6
50 mm dia G.I. Pipe with wall thickness 3.65 mm, outside diameter min 59.7 mm,
weight 5.38 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
rm
Tk.
1,083.00
26.38.7
62~65 mm dia G.I. Pipe with wall thickness 3.25 mm, outside diameter min 75.2 mm,
weight 6.15 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
rm
Tk.
1,541.00
26.38.8
75~80 mm dia G.I. Pipe with wall thickness 3.25 mm, outside diameter min 87.9 mm,
weight 7.22 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
rm
Tk.
1,899.00
26.38.9
100 mm dia G.I. Pipe with wall thickness 3.65 mm, outside diameter min 113 mm,
weight 10.42 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
rm
Tk.
2,520.00
26.39
Supplying different inside dia uPVC pressure pipe C-Grade / Having density 1350
kg/m3, opacity 0.2% of visible light as per ISO 7686, minimum required strength 25
MPa conforming to BDS-1:2013, 4.4.1, 4.4.2 for water supply having specific
gravity 1.35 - 1.45, and other physical, chemical, thermal, fire resistivity properties
etc. as per BSTI approved manufacturer standards or ASTM, BS/ISO/IS standards
fitted and fixed in position with sockets, bends, with all accessories such as Round
grating/domed roof grating, bends, sockets etc. approved and accepted by the
Engineer. (length: 6000 mm each)
Item No.
159
Description of Item
Unit
Unit Rate
26.39.1
rm
Tk.
152.00
26.39.2
rm
Tk.
200.00
26.39.3
rm
Tk.
214.00
26.39.4
rm
Tk.
277.00
26.39.5
rm
Tk.
325.00
26.39.6
rm
Tk.
411.00
26.39.7
rm
Tk.
546.00
26.39.8
rm
Tk.
674.00
26.39.9
rm
Tk.
920.00
26.40
Supplying different inside dia best quality CPVC pressure pipe Having density 1350
kg/m3, opacity 0.2% of visible light as per ISO 7686, minimum required strength 25
MPa conforming to BDS-1:2013, 4.4.1, 4.4.2 for water supply having specific
gravity 1.35 - 1.45, and other physical, chemical, thermal, fire resistivity properties
etc. as per BSTI approved manufacturer standards or ASTM, BS/ISO/IS standards
fitted and fixed in position with sockets, bends, with all accessories such as Round
grating/domed roof grating, bends, sockets etc. approved and accepted by the
Engineer. (length: 6000 mm each)
26.40.1
rm
Tk.
246.00
26.40.2
rm
Tk.
344.00
26.40.3
rm
Tk.
353.00
26.40.4
rm
Tk.
528.00
26.40.5
rm
Tk.
650.00
26.40.6
rm
Tk.
1,077.00
26.41
Supplying different inside dia best quality ABS pressure pipe for water supply
having specific gravity 1.35 - 1.45, and other physical, chemical, thermal, fire
resistivity properties etc. as per BSTI approved manufacturer standards or ASTM,
BS/ISO/IS standards fitted and fixed in position with sockets, bends, with all
accessories such as Round grating/domed roof grating, bends, sockets etc.
approved and accepted by the Engineer. (length: 6000 mm each)
26.41.1
rm
Tk.
406.00
26.41.2
rm
Tk.
470.00
26.41.3
rm
Tk.
439.00
26.41.4
rm
Tk.
780.00
26.41.5
rm
Tk.
983.00
Item No.
160
Description of Item
26.41.6
26.42
Supplying, fitting and laying HCI soil pipe each piece having over length 1800 mm,
thickness 5.5 mm, spigot diameter 116 mm, weight min 24.85 kg fitted and fixed in
position with sockets thickness min 6.5 mm, internal depth min 75 mm, bead's
outside diameter min 155 mm, ears flange length min 208 mm, caulking clearance
min 7.5 mm produced in foundry by grade pig iron as per BSTI approved
manufacturer standard fitting and fixing in position including head, shoes, bends,
trap, tee, offset, clamps and nails etc. complete in all floors approved and accepted
by the Engineer.
26.42.1
Unit
Unit Rate
rm
Tk.
1,725.00
rm
Tk.
1,561.00
26.42.2
rm
Tk.
2,089.00
26.43
Supplying, fitting and laying up to depth of invert 100 mm inside dia best quality
uPVC pressure soil pipe having specific gravity 1.3 -1.45, and other physical,
chemical, thermal, fire resistivity properties etc. as per BSTI approved manufacturer
standards or ASTM, BS/ISO/IS standards fitted and fixed in position with sockets,
bends, with all accessories such as Round grating/domed roof grating etc. complete
approved and accepted by the Engineer (length: 6000 mm each).
26.43.1
uPVC soil pipe 100 mm dia wall thickness 2.7 mm - 3.4 mm,
rm
Tk.
553.00
26.43.2
uPVC soil pipe 150 mm dia wall thickness 4.0 mm - 4.5 mm,
rm
Tk.
724.00
26.44
Supplying, fitting and fixing laying Pipes up to depth of invert dia R.C.C pipe having
1.83 meter in length made of stone chips with 40 mm cement joint including all
fittings and specials like plain bend, Tees, reducing sockets, junctions, door bends
cowls, anti-siphon, gasket and cement joints, making holes in walls and mending
good the damages etc. all complete approved and accepted by the Engineer.
26.44.1
rm
Tk.
864.00
26.44.2
rm
Tk.
1,347.00
26.44.3
rm
Tk.
2,213.00
26.44.4
rm
Tk.
2,843.00
26.45
Supplying 100 mm dia uPVC pipe for waste including fitting, fixing etc. all complete
approved and accepted by the Engineer.
rm
Tk.
575.00
26.46.1
Supplying 150 mm dia uPVC pipe for underground laying including fitting, fixing etc.
all complete approved and accepted by the Engineer.
rm
Tk.
764.00
26.46.2
Supplying 200 mm dia uPVC for underground laying including fitting, fixing etc. all
complete approved and accepted by the Engineer.
rm
Tk.
1,459.00
26.46.3
Supplying 250 mm dia uPVC for underground laying including fitting, fixing etc. all
complete approved and accepted by the Engineer.
rm
Tk.
2,019.00
26.46.4
Supplying uPVC waste pipe 280 mm dia with wall thickness 6.9 mm - 8.6 mm for
underground laying including fitting, fixing etc. all complete approved and accepted
by the Engineer.
rm
Tk.
2,463.00
Item No.
161
Description of Item
26.46.5
Supplying uPVC waste pipe 315 mm dia with wall thickness 7.7 mm - 9.7 mm for
underground laying including fitting, fixing etc. all complete approved and accepted
by the Engineer.
26.47
Supplying, fitting and fixing G.I. Union with sealant etc. complete in all respects
approved and accepted by the Engineer.
26.47.1
Unit
Unit Rate
rm
Tk.
3,368.00
each
Tk.
104.00
26.47.2
each
Tk.
136.00
26.47.3
each
Tk.
163.00
26.47.4
each
Tk.
209.00
26.47.5
each
Tk.
302.00
26.47.6
each
Tk.
357.00
26.47.7
each
Tk.
659.00
26.47.8
each
Tk.
843.00
26.47.9
each
Tk.
1,166.00
26.48
Supplying, fitting and fixing best quality G.I. gate valve with sealant etc. complete
approved and accepted by the Engineer.
26.48.1
each
Tk.
321.00
26.48.2
each
Tk.
521.00
26.48.3
each
Tk.
617.00
26.48.4
each
Tk.
876.00
26.48.5
each
Tk.
975.00
26.48.6
each
Tk.
1,631.00
26.48.7
each
Tk.
3,277.00
26.48.8
each
Tk.
4,386.00
26.48.9
each
Tk.
7,171.00
26.49
Supplying, fitting and fixing best quality G.I. Globe valve, threaded joint with sealant
etc. complete approved and accepted by the Engineer.
26.49.1
each
Tk.
321.00
26.49.2
each
Tk.
454.00
26.49.3
each
Tk.
753.00
Item No.
162
Description of Item
Unit
Unit Rate
26.49.4
each
Tk.
1,150.00
26.49.5
each
Tk.
1,350.00
26.49.6
each
Tk.
2,020.00
26.49.7
each
Tk.
3,341.00
26.49.8
each
Tk.
4,582.00
26.49.9
each
Tk.
6,279.00
26.50
Supplying, fitting and fixing best quality G.I. Check valve, threaded joint with sealant
etc. complete approved and accepted by the Engineer.
26.50.1
each
Tk.
357.00
26.50.2
each
Tk.
425.00
26.50.3
each
Tk.
617.00
26.50.4
each
Tk.
876.00
26.50.5
each
Tk.
1,035.00
26.50.6
each
Tk.
1,631.00
26.50.7
each
Tk.
2,797.00
26.50.8
each
Tk.
3,845.00
26.50.9
each
Tk.
6,211.00
26.51
Supplying, fitting and fixing best quality G.I. Float valve, threaded joint Pit valve etc.
complete approved and accepted by the Engineer.
26.51.1
each
Tk.
337.00
26.51.2
each
Tk.
444.00
26.51.3
each
Tk.
494.00
26.51.4
each
Tk.
835.00
26.51.5
each
Tk.
1,113.00
26.52
Supplying, fitting and fixing European type HCI P-Trap drainage pipe preparing the
base with cement concrete in 1:2:4 and with wire mesh or rods if necessary, in all
floors including making holes wherever required and mending good the damages
and fitting, fixing complete with all necessary fittings and connection approved and
accepted by the Engineer.
26.52.1
each
Tk.
1,109.00
26.52.2
each
Tk.
1,249.00
Item No.
163
Description of Item
Unit
Unit Rate
26.52.3
each
Tk.
1,572.00
26.52.4
each
Tk.
1,431.00
26.53
Supplying different inside dia best quality uPVC pressure waste pipe having
specific gravity 1.35 -1.45, wall thickness 2.7 mm - 3.4 mm, and other physical,
chemical, thermal, fire resistivity properties etc. as per BSTI approved manufacturer
standards or ASTM, BS/ISO/IS standards, fitted and fixed in position with sockets,
bends, with all accessories such as Round grating/domed roof grating bands,
sockets etc. complete approved and accepted by the Engineer.
26.53.1
each
Tk.
491.00
26.53.2
each
Tk.
575.00
26.53.3
each
Tk.
669.00
26.53.4
each
Tk.
490.00
26.54.
Supplying, fitting and fixing best quality faucets etc. complete approved and
accepted by the Engineer
26.54.1
12 mm CP bib cock
each
Tk.
682.00
26.54.2
each
Tk.
1,063.00
26.54.3
each
Tk.
195.00
26.55
Supplying, fitting and fixing best quality CP pillar cock etc. complete approved and
accepted by the Engineer
26.55.1
each
Tk.
840.00
26.55.2
each
Tk.
978.00
26.56
Supplying, fitting and fixing best quality concealed fixed sink cock etc. complete
approved and accepted by the Engineer
26.56.1
each
Tk.
921.00
26.56.2
each
Tk.
967.00
26.57.1
Supplying, fitting and fixing CP Basin Mixture with all necessary hardware and
consumables approved and accepted by the Engineer.
each
Tk.
2,338.00
26.57.2
Supplying, fitting and fixing CP Single Handle Basin Mixture with all necessary
hardware and consumables approved and accepted by the Engineer.
each
Tk.
1,934.00
26.58
Supplying, fitting and fixing CP Shower Mixture including Shower Head only with
all necessary hardware and consumables approved and accepted by the Engineer.
each
Tk.
3,404.00
26.59
Supplying, fitting and fixing CP Shower Mixture including Shower Head and
faucet with all necessary hardware and consumables approved and accepted by the
Engineer.
each
Tk.
4,867.00
Item No.
164
Description of Item
Unit
Unit Rate
26.60
Supplying, fitting and fixing CP Bath tub Mixture with Shower Head only including
all necessary hardware and consumables approved and accepted by the Engineer.
each
Tk.
5,110.00
26.61
Supplying, fitting and fixing CP Self closing pillar cock with all necessary hardware
and consumables approved and accepted by the Engineer
each
Tk.
971.00
26.62
Supplying, fitting and fixing Special/Fancy quality C.P. concealed/ surface stop
cock with all necessary hardware and consumables approved and accepted by the
Engineer.
26.62.1
each
Tk.
307.00
26.62.2
each
Tk.
382.00
26.62.3
each
Tk.
919.00
26.62.4
each
Tk.
1,018.00
26.62.5
each
Tk.
1,077.00
26.62.6
each
Tk.
1,175.00
26.63
Supplying, fitting and fixing Special/Fancy quality C.P. concealed/ Surface Angle
stop cock etc. complete approved and accepted by the Engineer.
26.63.1
each
Tk.
789.00
26.63.2
12 mm CP medium quality surface & heavy type fancy angle stop cock
each
Tk.
827.00
26.63.3
each
Tk.
795.00
26.63.4
each
Tk.
647.00
26.63.5
each
Tk.
795.00
26.63.6
each
Tk.
952.00
26.64
Groove cutting in brick work, R.C.C floor, including cost for concealing of G.I. pipe
work (12 mm and 20 mm dia) in brick wall by cutting groove in wall, lintel, beam etc.
by any means carefully without damaging the structure and filling the grooves with
C.C (4:2:1) after laying of pipe including cost of scaffolding, finishing, curing etc. all
complete approved and accepted by the Engineer.
26.64.1
rm
Tk.
49.00
26.64.2
rm
Tk.
74.00
26.65
Supply and fitting-fixing cleansing shower for ablution including holder of following
types:
26.65.1
each
Tk.
610.00
26.65.2
each
Tk.
1,008.00
26.66
Supply and fitting-fixing hand / push shower for ablution including holder
Item No.
165
Description of Item
Unit
Unit Rate
26.66.1
each
Tk.
2,628.00
26.66.2
each
Tk.
899.00
26.67
Supplying, fitting fixing of food grade plastic overhead water reservoir tank
including all necessary fittings, hardware and consumables etc. all complete
approved and accepted by the Engineer.
26.67.1
each
Tk.
13,381.00
26.67.2
each
Tk.
19,537.00
26.67.3
each
Tk.
25,790.00
26.68
Supply and installation of food-grade plastic internal mini water tank for the use in
kitchen, bathroom and toilet for emergency storage and supply of water
manufactured from liner low density polyethylene (ILDPE) roto-grade (ultra violet)
stabilized which complies FDA (Federal Department of Agriculture, USA) regulations
21 CFR 1277. 152, having food grade quality where no recycled material is used
carrying, lifting, fitting, fixing in position including supply of necessary hardware,
consumables, fittings etc. all complete approved and accepted by the Engineer.
26.68.1
each
Tk.
3,816.00
26.68.2
each
Tk.
5,979.00
26.68.3
each
Tk.
7,882.00
26.69
Supply and installation of foreign made food grade stainless steel water tank
including supply of hardware, consumables, fittings etc. all complete approved and
accepted by the Engineer.
26.69.1
each
Tk.
10,862.00
26.69.2
each
Tk.
19,005.00
26.69.3
each
Tk.
32,035.00
26.69.4
each
Tk.
63,293.00
26.69.5
each
Tk.
68,740.00
26.70
Supply and installation of 400 gallon capacity Ferro-cement water tank including
necessary hardware, fittings and consumables etc. all complete approved and
accepted by the Engineer.
each
Tk.
7,886.00
26.71
Supplying, fitting and fixing 12 mm dia, 450 mm long Plastic flexible lead
(connection) pipe approved and accepted by the Engineer.
each
Tk.
65.00
26.72
Supplying, fitting and fixing 12 mm dia, 600 mm long Plastic flexible lead
(connection) pipe approved and accepted by the Engineer.
each
Tk.
99.00
26.73
Supplying, fitting and fixing 12 mm dia 450 mm long metal cover connection pipe
approved and accepted by the Engineer.
each
Tk.
350.00
Item No.
26.74
166
Description of Item
Unit
Unit Rate
Supplying, fitting and fixing 12 mm dia 600 mm long metal cover connection pipe
approved and accepted by the Engineer.
each
Tk.
399.00
Construction of masonry inspection pit with 250 mm thick brick work in cement
mortar (1:4) including necessary earth work, side filling and one layer brick flat
soling, 75 mm thick (1:3:6) base concrete for making invert channel and 12 mm thick
(1:2) cement plaster with neat finishing etc. all complete up to a depth of 700 mm
approved and accepted by the Engineer.
26.75.1
Clear 450 x 450 mm and depth 450 to 600 mm, average 525 mm for single 150 mm
dia R.C.C. pipes and 400 mm PVC pipe.
each
Tk.
3,433.00
26.75.2
Clear 520 x 525 mm and depth 675 to 825 mm, average 750 mm for single 225 mm
dia R.C.C. pipes and 400 mm PVC pipe.
each
Tk.
5,012.00
26.75.3
Clear 600 x 600 mm and depth 750 to 900 mm, average 825 mm for single 300 mm
dia R.C.C. pipes and 375 mm and 400 mm PVC pipe.
each
Tk.
6,882.00
26.75.4
Master-pit of Size: Clear 600 x 500 mm and average 750 mm depth for Septic tank.
each
Tk.
3,710.00
26.76
Construction and placing of R.C.C. inspection pit cover (slab) in (1:2:4) with 1%
reinforcement excluding M.H. cover with locking/unlocking arrangement including
necessary earth work, side filling shuttering, curing, cement plaster (1:4) with neat
finishing on edges and top etc. all complete approved and accepted by the Engineer.
26.76.1
each
Tk.
1,309.00
26.76.2
each
Tk.
1,512.00
26.76.3
each
Tk.
1,734.00
26.77
Construction and placing of R.C.C inspection pit cover (slab) with supplying and
provisions for placing, fitting, fixing 450 mm dia C.I. Man-hole cover with locking/unlocking arrangement including concrete (1:2:4) with approx. 1% re-enforcement,
necessary earth cutting, or cleaning, side filling, curing etc. with minimum 12 mm
cement plaster (1:4) and neat cement finishing on edges and top all complete and
accepted by the Engineer.
26.77.1
950 x 950 x 75 mm R.C.C. pit cover with 450 mm dia C.I. manhole cover.
each
Tk.
2,371.00
26.77.2
1025 x 1025 x 75 mm R.C.C. pit cover with 450 mm dia C.I. manhole cover.
each
Tk.
2,534.00
26.77.3
1100 x 1100 x 75 mm R.C.C. pit cover with 450 mm dia C.I. manhole cover.
each
Tk.
2,755.00
26.78
26.78.1
Clear 450 x 450 mm and depth 450 to 600 mm, average 525 mm for single 150 mm
dia R.C.C. pipes and 400 mm PVC pipe with pit cover and 450 mm dia C.I. man-hole
cover.
each
Tk.
5,804.00
Item No.
167
Description of Item
Unit
Unit Rate
26.78.2
Clear 525 x 525 mm and depth 675 to 825 mm, average 750 mm for single 225 mm
dia R.C.C. pipes and 400 mm PVC pipe with pit cover and 450 mm dia C.I. man-hole
cover.
each
Tk.
7,546.00
26.78.3
Clear 600 x 600 mm and depth 750 to 900 mm, average 825 mm for single 300 mm
dia R.C.C. pipes and 375 mm and 400 mm PVC pipe with pit cover and 450 mm dia
C.I. man-hole cover.
each
Tk.
9,637.00
26.79
Construction of septic tank of different sizes with walls of brick work in cement
mortar (1:6) having a lining of minimum 125 mm R.C.C cast against the walls as per
approved type plan over a brick flat soling and 150 mm thick reinforced cement
concrete flooring (1:2:4) with 125 mm thick walls in partition and 12 mm thick cement
plaster (1:4) with N.C.F. to insides of walls on floor and all around outside walls by
18" height at top including supplying fitting and fixing of two R.C.C. Tees and
providing 450 mm dia water sealed heavy type C.I. manhole cover with
locking/unlocking arrangement and 100 mm thick R.C.C (1:2:4) top slab, including
centering, shuttering, fabricating, casting and curing etc. complete up to required
depth including necessary earth work in excavation and shoring, bailing out water
and side filling including the cost of all materials, operations and incidental charges.
etc. all complete as per type plan approved and accepted by the Engineer. (Rate is
including cost of reinforcement and its fabrication, binding and placing)
26.79.1
each
Tk.
235,777.00
26.79.2
each
Tk.
183,339.00
26.79.3
For 50 users
each
Tk.
121,488.00
26.79.4
For 30 users
each
Tk.
84,996.00
26.79.5
For 20 users
each
Tk.
80,127.00
26.79.6
For 10 users
each
Tk.
46,516.00
26.80
Construction of soak well of different sizes (medium and large sizes) with 250 mm
thick solid brick work and 250 mm honey comb brick work with cement mortar (1:6)
as per design over R.C.C. (1:2:4) well curb with 1% reinforcement up to the depth as
per drawing with 450 mm dia water sealed heavy type. C.I. manhole cover with
locking arrangement, filling the well up to the required depth with graded khoa and
sand including supplying and fabricating M.S. Rod, casting, curing including
necessary earth work in excavation, side filling and bailing out water including cost of
all materials etc. all complete as per drawing, design approved and accepted by the
Engineer. (Rate is including cost of reinforcement and its fabrication, binding and
placing)
26.80.1
200 users
each
Tk.
76,366.00
26.80.2
100 users
each
Tk.
67,733.00
26.80.3
50 users
each
Tk.
57,356.00
Item No.
168
Description of Item
Unit
Unit Rate
26.81
Construction of soak well of different sizes (small sizes) with 250 mm thick solid
brick work and 250 mm honey comb brick work with cement mortar (1:6) as per
design over R.C.C. (1:2:4) well curb with 1% reinforcement up to the depth as per
drawing with 450 mm dia water sealed heavy type. C.I. manhole cover with locking
arrangement, filling the well up to the required depth with graded khoa and sand
including supplying and fabricating M.S. Rod, casting, curing including necessary
earth work in excavation, side filling and bailing out water including cost of all
materials etc. all complete as per drawing, design approved and accepted by the
Engineer.
26.81.1
20 to 30 users
each
Tk.
48,863.00
26.81.2
10 users
each
Tk.
33,790.00
26.82
Supplying, fitting, fixing of Reverse Osmosis Water Purifier of foreign made for
purification of water by reverse osmosis system to have potable water confirming
WHO standard and Bangladesh concentration parameters including installation
charge, carriage, sundries etc. complete approved and accepted by the Engineer.
(excluding cost of pipe, pipe line laying and accessories required for pipe line laying)
26.82.1
each
Tk.
21,318.00
26.82.2
each
Tk.
25,238.00
26.82.3
each
Tk.
26,636.00
26.82.4
each
Tk.
79,433.00
26.83
each
Tk.
4,391.00
26.84
each
Tk.
666.00
Item No.
169
Description of Item
Unit
Unit Rate
Unit
Rate
Description of Item
(Note: Tender for test & observation well must be called beforehand. Tender
for main production well will then be called on the basis of required data
obtained from the test well. Requirements of water must be guiding factor in
dimensioning the main well.
SINKING OF 38 mm DIA TEST AND OBSERVATION WELL
27.1
Per set
Tk.
7,034.00
27.2
Boring by using 100 mm dia cutter and 40 mm dia heavy type G.I pipe having wall
thickness 2.9 mm, outside diameter min 47.8 mm, weight 3.517 kg/m, capability to
withstand 50 kg/cm2 and other equipments capable of drilling up to a depth 500
meter by water jet system through all sorts of strata. Protection of caving by
supplying necessary casing pipe. Collection of soil samples at every 3 meter interval
and at every change of strata and preserves them in a controlled environment for
analysis and laboratory test. Finally withdrawal of boring and casing pipes etc.
complete and accepted by the Engineer.
27.2.1
From 0.0 m to 50 m = 50 m
rm
Tk.
154.00
27.2.2
From 50 m to100 m = 50 m
rm
Tk.
177.00
27.2.3
rm
Tk.
203.00
27.2.4
rm
Tk.
234.00
27.2.5
rm
Tk.
269.00
27.2.6
Beyond 250 m
rm
Tk.
309.00
27.3
27.3.1
Fitting, fixing No. 6 Hand-pump set including all necessary accessories etc complete
and accepted by the Engineer.
each
Tk.
2,738.00
Item No.
170
Description of Item
Unit
Unit Rate
27.3.2
38/40 mm dia heavy type G.I pipe conforming to standard BS-1387 & BDS-1031,
having chemical composition (in%) Carbon 0.17-0.25, Manganese 0.95-1.20,
Sulphur 0.060 max, Phosphorous 0.060 max, Tensile properties: miminum Yield
Strength 188 MPa, minimumTensile Strength 313 MPa and marking for a)
Manufacturer b) Material c) Wall thickness d) Nominal outside dia e) Intended use
etc. on the body of the pipe having wall thickness 2.9 mm, weight 3.517 kg/m
capability to withstand 50 kg/cm2 hydraulic pressure.
rm
Tk.
680.00
27.3.3
38/40 mm dia water grade uPVC pipe having wall thickness 2.5-3.00 mm
rm
Tk.
141.00
27.3.4
rm
Tk.
175.00
27.3.5
each
Tk.
87.00
27.3.6
each
Tk.
66.00
27.3.7
Supplying, fitting fixing observation well inside the housing pipe of the deep tube
well: 100'-0" depth
each
Tk.
21,806.00
27.3.8
Supplying, fitting fixing tube-well log describing technical information of the tube-well
as per instruction and accepted by the Engineer.
each
Tk.
2,859.00
27.3.9
Filling the top 0.6 meter of the bore hole around the top pipe with sanitary seal of
concrete of proportion 1:2:4 as per design accepted by the Engineer.
each
Tk.
51.00
27.4
Complete development of the tube well to obtain sand and turbidity free water at a
satisfactory yield confirmed by tests as per specification and accepted by the
Engineer. Water sample must be taken from 3 separate aquifers from three tubewell.
27.4.1
27.4.1.1
L.S.
Tk.
6,186.00
27.4.1.2
L.S.
Tk.
9,279.00
27.4.1.3
L.S.
Tk.
12,372.00
27.4.2
27.4.2.1
rm
Tk.
35.57
27.4.2.2
rm
Tk.
53.35
27.4.2.3
rm
Tk.
71.14
Item No.
27.5
171
Description of Item
Unit
Unit Rate
"Furnishing design of a production well by testing of water and soil samples from
a test bores up to 350 m depth collecting samples of water from the best suitable
aquifer, filling in sterilized air-tight glass bottles having no air space inside; collecting
soil (sand, solids etc) at 3 m interval and at each change of soil strata from the bores,
arranging them in the cell of a box in an orderly manner. carrying out test of water for
(1) pH, (2) CO2 (3) Chloride, (4) Fluoride, (5) Iron, (6) Manganese, (7) NitrateNitrogen, (8)Total alkalinity, (9) Total hardness, (10) Arsenic, (11) Turbidity, followed
by test reports along with Bangladesh Standards of potable water and (12) Sieve
analysis on soils throughout a bore, leading to ascertain the best suitable sustained
aquifers, depths and slot sizes of strainer, types and dia of tube well for specific
yield, thickness of shrouding around strainer, fineness modulus of shrouding
materials, mechanical units (pumps, compressor) for testing and operation of the
tube well, maintaining test bore functional till tube well installation, testing etc. is
finished, finally filling and sealing the left over test bore permanently, including
carrying water and soil samples under direct responsibility of Engineer-in-charge to
BRTC, BUET or other reputed laboratory, approved by the authority, submitting the
report and design details all complete and accepted by the Engineer and maintaining
the mobilized tools and plant at site till satisfactory test results are found (if not, next
test bore may be executed with the approval of concern S.E. / Design Office)
Total No. of test on water: 11 types of test x 1 test bore x one set sample (3
specimen) = 11 Nos. test (each specimen 1.5 liter of water)
Sieve analysis: min 9 Nos. Sample x one test x One bore = 9 Nos. test
(Samples are of 1 kg dry wt. each)"
There are about 55 (fifty-five) tests for potable water Quality Standard according to
Bangladesh Environment Conservation Rules-12 (Schedule-3), 1997, under ECA
1995 of Ministry of Environment and Forest. Therefore, additional test/ tests on water
or sieve analysis of soil if required, other than the above specified 12 (twelve) tests,
may be carried out for public interest as per direction of the design engineer on
actual payment including profit, VAT and all other charges.
27.5.1
L.S.
Tk.
32,223.00
27.5.2
L.S.
Tk.
53,237.00
27.5.3
L.S.
Tk.
79,855.00
27.6
each
Tk.
380.00
Per set
Tk.
35,302.00
PRODUCTION WELL
27.7
27.7.1
Item No.
172
Description of Item
Unit
Unit Rate
27.7.2
Per set
Tk.
37,824.00
27.7.3
Per set
Tk.
40,345.00
27.8
Preparation and making gravel pack around the tube well fixtures with supply of
designed graded pea gravels free from any substance harmful to pipe and health
confirmed by test (Passing through 10 mesh and retained on 40 mesh) including
sieving, washing etc. complete as per standard specification and accepted by the
Engineer. (The rate is inclusive of the cost of extra amount required for caving and
extra depth below the tube well fixtures, shrouding should not be more than 15 m
above the strainer and measurement should be allowed from bottom of the tube-well
fixture to top of the gravel pack)
cum
Tk.
3,087.00
27.9
cum
Tk.
7,982.00
Boring: Execution 325 mm dia of boring through all sorts of strata by reverse
circulation or any other approved method (Method other than reverse circulation is to
be applied only for wells deeper than 152 meter). Boring for 325 mm dia vertical hole
up to designed depth and collection of soil samples at every 3 meter interval or as
required and at every change in soil stratum including sinking and with drawing
necessary casing pipe and all necessary arrangements complete as per specification
and accepted by the Engineer. (Measurement will be allowed from E.G.L. to bottom
of the blind pipe and the rate is inclusive of the cost of extra depth or of further boring
required due to caving and siltation)
27.10.1
From 0.0 m to 50 m = 50 m
rm
Tk.
750.00
27.10.2
From 50 m to 100 m = 50 m
rm
Tk.
862.00
27.10.3
rm
Tk.
992.00
27.10.4
rm
Tk.
1,140.00
27.10.5
rm
Tk.
1,311.00
27.10.6
Beyond 250 m
rm
Tk.
1,508.00
27.11
Supplying the following tube well fixtures and pipes having density 1350 kg/m3,
opacity 0.2% of visible light as per ISO 7686, minimum required strength 25 MPa
conforming to BDS-1:2013, 4.4.1, 4.4.2 at working site as per standard practice and
accepted by the Engineer.
27.11.1
each
Tk.
90.00
27.11.2
50 mm dia water grade uPVC blind pipe/sand trap of wall thickness 2.5 to 3.00 mm
rm
Tk.
182.00
27.11.3
50 mm dia strainer of any slot as per design made with grade uPVC pipe of wall
thickness 2.5 to 3 mm
rm
Tk.
221.00
Item No.
173
Description of Item
27.11.4
27.11.5
125mm dia water grade uPVC Housing pipe of wall thickness 5.5 to 6.4mm
27.11.6
Unit
Unit Rate
rm
Tk.
607.00
each
Tk.
736.00
rm
Tk.
364.00
27.12
rm
Tk.
66.00
27.13
Complete development of the tube well by air compressor and pump of suitable
capacity by alternate surging and pumping or any specified method until satisfactory
yield. is achieved in sand and turbid free water confirmed by laboratory test using
necessary quantity of cologne and conducting step drawn-down test before and after
the development as per specification and accepted by the Engineer.
(Development should be started within 24 hours of completion of shrouding)
27.13.1
each
Tk.
22,308.00
27.13.2
each
Tk.
28,257.00
27.14
Per hour
Tk.
651.00
27.15
each
Tk.
1,106.00
27.16
Filling of the borehole around the tube well from top of the shrouding up to the
bottom of sanitary seal by withdrawn selected soil or local clay free from any
substances harmful to pipes and health as per standard specification and accepted
by the Engineer.
rm
Tk.
24.00
Item No.
27.17
174
Description of Item
Unit
Unit Rate
Protective top cover: Supplying and fitting fixing best quality 150 mm dia 4 mm
thick MS. Pipe 1.0 m (3'-4") long one end blocked with 200 mm dia 4 mm thick M.S.
plate and other end minimum 300 mm (1'-0") embedded in sanitary seal for
protection of uPVC Housing Pipe as per standard specification and accepted by the
Engineer.
each
Tk.
3,826.00
Boring: Execution 350 mm dia of boring through all sorts of strata by reverse
circulation or any other approved method (Method other than reverse circulation is to
be applied only for wells deeper than 152 meter). Boring for 350 mm dia vertical hole
up to designed depth and collection of soil samples at every 3 meter interval or as
required and at every change in soil stratum including sinking and with drawing
necessary casing pipe and all necessary arrangements complete as per specification
and accepted by the Engineer. (Measurement will be allowed from E.G.L. to bottom
of the blind pipe and the rate is inclusive of the cost of extra depth or of further boring
required due to caving and siltation)
27.18.1
From 0.0 m to 50 m = 50 m
rm
Tk.
792.00
27.18.2
From 50 m to100 m = 50 m
rm
Tk.
910.00
27.18.3
rm
Tk.
1,047.00
27.18.4
rm
Tk.
1,204.00
27.18.5
rm
Tk.
1,384.00
27.18.6
Beyond 250 m
rm
Tk.
1,592.00
27.19
Supplying the following tube well fixtures and having density 1350 kg/m3, opacity
0.2% of visible light as per ISO 7686, minimum required strength 25 MPa conforming
to BDS-1:2013, 4.4.1, 4.4.2 at working site as per standard practice and accepted by
the Engineer.
27.19.1
each
Tk.
123.00
27.19.2
75 mm dia water grade uPVC blind pipe/sand trap of wall thickness 3.5 to 4.1 mm
rm
Tk.
312.00
27.19.3
75 mm dia strainer of any slot as per design made with grade uPVC pipe of wall
thickness 3.5 to 4.1 mm
rm
Tk.
347.00
27.19.4
each
Tk.
769.00
27.19.5
150 mm dia water grade uPVC Housing pipe having wall thickness 6.6 mm to 7.6
mm
rm
Tk.
953.00
27.19.6
rm
Tk.
364.00
Item No.
175
Description of Item
Unit
Unit Rate
27.20
rm
Tk.
74.00
27.21
Complete development of the well by suitable air compressor and pump of suitable
capacity by alternate surging and pumping un till satisfactory yield, sand free water
and the turbidity condition is reached using necessary quantity of calgon and
conducting step draw down test before and after the development as per
specification and accepted by the Engineer. (Development should be started within
24 hours of completion of shrouding)
27.21.1
each
Tk.
28,390.00
27.21.2
each
Tk.
34,068.00
27.22
Pumping test of the well by designed turbine/submersible pump with supply of testing
equipments for pressure/ velocity/ discharge etc. and all materials for 72 hours
including yield drawn and recovery test etc. complete as per specification and
accepted by the Engineer.
hour
Tk.
807.00
27.23
each
Tk.
1,342.00
27.24
Filling of the bore-hole around the tube well from top of the shrouding up to the
bottom of sanitary seal by withdrawn selected soil or local clay free from any
substances harmful to pipes and health as per standard specification and accepted
by the Engineer.
rm
Tk.
28.00
27.25
Protective top cover: Supplying and fitting fixing best quality 200 mm dia 4 mm
thick M.S. pipe 1.0 m (3'-4") long one end blocked with 250 mm dia 4 mm thick M.S.
plate and other end minimum 300 mm (1'-0) embedded in sanitary seal for protection
of uPVC housing pipe as per standard specification and accepted by the Engineer.
each
Tk.
5,317.00
Boring: Execution 400 mm dia of boring through all sorts of strata by reverse
circulation or any other approved method (Method other than reverse circulation is to
be applied only for wells deeper than 152 meter) Boring for 400 mm dia vertical hole
up to designed depth and collection of soil samples at every 3 meter interval or as
required and at every change in soil stratum including sinking and with drawing
necessary casing pipe and all necessary arrangements complete as per specification
and accepted by the Engineer.(Measurement will be allowed from E.G.L. to bottom
of the blind pipe and the rate is inclusive of the cost of extra depth or of further boring
required due to caving and siltation)
27.26.1
From 0.0 m to 50 m = 50 m
rm
Tk.
833.00
27.26.2
From 50 m to 100 m = 50 m
rm
Tk.
958.00
27.26.3
rm
Tk.
1,102.00
Item No.
176
Description of Item
Unit
Unit Rate
27.26.4
rm
Tk.
1,267.00
27.26.5
rm
Tk.
1,457.00
27.26.6
Beyond 250 m
rm
Tk.
1,676.00
27.27
Supplying the following tube well fixtures and pipes Having density 1350 kg/m3,
opacity 0.2% of visible light as per ISO 7686, minimum required strength 25 MPa
conforming to BDS-1:2013, 4.4.1, 4.4.2 at working site as per standard practice and
accepted by the Engineer
27.27.1
each
Tk.
198.00
27.27.2
100 mm dia water grade uPVC blind pipe/ sand trap having wall thickness 4.5mm to
5.2mm
rm
Tk.
472.00
27.27.3
100 mm dia strainer of any slot as per design made with water grade uPVC pipe
having wall thickness 4.5 mm to 5.2 mm
rm
Tk.
507.00
27.27.4
each
Tk.
861.00
27.27.5
200 mm dia water grade uPVC Housing pipe having wall thickness 6.6mm to 7.8mm
to 9.0mm
rm
Tk.
804.00
27.27.6
rm
Tk.
364.00
27.28
rm
Tk.
85.00
27.29
27.29.1
each
Tk.
35,123.00
27.29.2
each
Tk.
42,147.00
27.30
hour
Tk.
852.00
27.31
each
Tk.
1,579.00
Item No.
177
Description of Item
Unit
Unit Rate
27.32
Filling of the borehole around the tube-well from top of the shrouding up to the
bottom of sanitary seal by withdrawn selected soil or local clay free from any
substances harmful to pipes and health as per standard specification and accepted
by the Engineer.
rm
Tk.
32.00
27.33
Protective top cover: Supplying and fitting fixing best quality 250 mm dia 4 mm
thick M.S. pipe. 1.0 m (3'-4") long one end blocked with 300 mm dia 4 mm thick M.S.
plate and other end minimum 300 (1'-0") embedded in sanitary seal for protection of
uPVC Housing pipe as per standard specification and accepted by the Engineer.
each
Tk.
8,468.00
Boring: Execution 600 mm dia of boring through all sorts of strata by reverse
circulation or any other approved method (Method other than reverse circulation is to
be applied only for wells deeper than 152 meter). Boring for 600 mm dia vertical hole
up to designed depth and collection of soil samples at every 3 meter interval or as
required and at every change in soil stratum including sinking and with drawing
necessary casing pipe and all necessary arrangements complete as per specification
and accepted by the Engineer. (Measurement will be allowed from E.G.L. to bottom
of the blind pipe and the rate is inclusive of the cost of extra depth or of further boring
required due to caving and siltation)
27.34.1
From 0.0 m to 50 m = 50 m
rm
Tk.
1,020.00
27.34.2
From 50 m to 100 m = 50 m
rm
Tk.
1,173.00
27.34.3
rm
Tk.
1,349.00
27.34.4
rm
Tk.
1,551.00
27.34.5
rm
Tk.
1,783.00
27.34.6
Beyond 250 m
rm
Tk.
2,051.00
27.35
Supplying the following tube-well fixtures and pipes having density 1350 kg/m3,
opacity 0.2% of visible light as per ISO 7686, minimum required strength 25 MPa
conforming to BDS-1:2013, 4.4.1, 4.4.2 at working site as per standard practice and
accepted by the Engineer.
27.35.1
Best quality 150 mm dia uPVC cap for blind pipe/ sand trap.
each
Tk.
473.00
27.35.2
150 mm dia water grade uPVC blind pipe/ sand trap having wall thickness 6.6 mm
to7.6 mm
rm
Tk.
1,042.00
27.35.3
150 mm dia strainer of any slot as per design made with grade uPVC pipe of wall
thickness 6.6 to 7.6 mm
rm
Tk.
1,086.00
27.35.4
each
Tk.
999.00
27.35.5
200 mm dia water grade uPVC Housing pipe of wall thickness 6.6 mm to 7.8 mm
rm
Tk.
1,668.00
27.35.6
rm
Tk.
364.00
Item No.
178
Description of Item
Unit
Unit Rate
27.36
rm
Tk.
90.00
27.37
Complete development of the tube well by suitable air compressor and pump of
suitable capacity by alternate surging and pumping until satisfactory yield, sand free
water and the turbidity condition is reached using necessary quantity of calgon and
conducting step draw down test before and after the development as per
specification and accepted by the Engineer. (Development should be started within
24 hours of completion of shrouding)
27.37.1
each
Tk.
41,814.00
27.37.2
each
Tk.
47,390.00
27.38
hour
Tk.
973.00
27.39
each
Tk.
1,895.00
27.40
Filling of the borehole around the tube well from top of the shrouding up to the
bottom of sanitary seal by withdrawn selected soil or local clay as free from any
substances harmful to pipes and health per standard specification and accepted by
the Engineer.
rm
Tk.
43.00
27.41
Protective top cover: Supplying and fitting fixing best quality 250 mm dia 4 mm
thick M.S. pipe 1.0 m (3'-4") long one end blocked with 300 dia 4 mm thick M.S. plate
and other end minimum 300 (1'-0") embedded in sanitary seal for protection of uPVC
Housing pipe as per standard specification and accepted by the Engineer.
each
Tk.
8,343.00
Boring: Execution of 600 mm dia boring through all sorts of strata by reverse
circulation or any other approved method (Method other than reverse circulation is to
be applied only for wells deeper than 152 meter) for boring 600 mm dia vertical hole
up to designed depth and collection of soil samples at every 3 meter interval and at
every change of formation including sinking and withdrawing necessary casing pipe
and all necessary arrangements complete as per specification and accepted by the
Engineer. (Measurement will be allowed from G.L. to bottom of the blind pipe and the
rate is inclusive of the cost of extra depth of boring required for caving and siltation)
27.42.1
From 0.0 m to 50 m = 50 m
rm
Tk.
1,020.00
27.42.2
From 50 m to 100 m = 50 m
rm
Tk.
1,173.00
27.42.3
rm
Tk.
1,349.00
27.42.4
rm
Tk.
1,551.00
27.42.5
rm
Tk.
1,783.00
Item No.
179
Description of Item
27.42.6
Beyond 250 m
27.43
Supplying the following tube well fixtures and pipes conforming to standard BS1387 & BDS-1031, having chemical composition (in%) Carbon 0.17-0.25,
Manganese 0.95-1.20, Sulphur 0.060 max, Phosphorous 0.060 max, Tensile
properties: miminum Yield Strength 188 MPa, minimumTensile Strength 313 MPa
and marking for a) Manufacturer b) Material c) Wall thickness d) Nominal outside dia
e) Intended use etc. on the body of the pipe at working site as per standard practice
and accepted by the Engineer.
27.43.1
27.43.2
150 mm dia G.I. Pipe having wall thickness 5.4 mm, weight 21.2 kg/m can withstand
50 kg/ cm2 hydraulic pressure for blind pipe/sand trap
27.43.3
150 mm dia strainer of slot opening as per design including tagging 4 Nos. 12 mm
dia M.S. rod continuously.
27.43.3.1
Unit
Unit Rate
rm
Tk.
2,051.00
each
Tk.
1,213.00
rm
Tk.
3,031.00
Stainless steel strainer of continuous slot having weight 28.84 kg per meter.
rm
Tk.
14,871.00
27.43.3.2
rm
Tk.
10,700.00
27.43.4
rm
Tk.
3,510.00
27.43.5
each
Tk.
6,197.00
27.43.6
rm
Tk.
9,970.00
27.43.7
each
Tk.
364.00
27.43.8
350 mm dia M.S. cap having 6 mm thick for housing pipe covering.
each
Tk.
2,036.00
27.44
rm
Tk.
351.00
27.45
Complete development of the tube well by suitable air compressor and pump of
suitable capacity by alternate surging and pumping until satisfactory yield, sand free
water and the turbidity condition is reached using necessary quantity of calgon and
conducting step draw down test before and after the development as per
specification and accepted by the Engineer. (Development should be started within
24 hours of completion of shrouding)
27.45.1
each
Tk.
41,814.00
27.45.2
each
Tk.
47,390.00
27.46
hour
Tk.
1,002.00
Item No.
180
Description of Item
Unit
Unit Rate
27.47
each
Tk.
1,935.00
27.48
Filling of the borehole around the tube well from top of the shrouding up to the
bottom of sanitary seal by withdrawn selected soil or local clay free from any
substances harmful to pipes and health as per standard specification and accepted
by the Engineer.
rm
Tk.
43.00
Boring: Execution of 800 mm dia boring through all sorts of strata by reverse
circulation or any other approved method (Method other than reverse circulation is
to be applied only for wells deeper than 152 meter). For boring 800 mm dia vertical
hole up to designed depth and collection of soil samples at every 3 meter interval
and at every change of formation including sinking and withdrawing necessary
casing pipe and all necessary arrangements complete as per specification and
accepted by the Engineer. (Measurement will be allowed form G.L. to bottom of the
blind pipe and the rate is required for caving and siltation)
27.49.1
From 0.0 m to 50 m = 50 m
rm
Tk.
1,137.00
27.49.2
From 50 m to 100 m = 50 m
rm
Tk.
1,308.00
27.49.3
rm
Tk.
1,504.00
27.49.4
rm
Tk.
1,730.00
27.49.5
rm
Tk.
1,989.00
27.49.6
Beyond 250 m
rm
Tk.
2,288.00
27.50
Supplying the following tube-well fixtures and pipes conforming to standard BS1387 & BDS-1031, having chemical composition (in%) Carbon 0.17-0.25,
Manganese 0.95-1.20, Sulphur 0.060 max, Phosphorous 0.060 max, Tensile
properties: miminum Yield Strength 188 MPa, minimumTensile Strength 313 MPa
and marking for a) Manufacturer b) Material c) Wall thickness d) Nominal outside dia
e) Intended use etc. on the body of the pipe at working site as per standard practice
and accepted by the Engineer.
27.50.1
200 mm dia M.S. cap 6mm thick for blind pipe/ sand strap
each
Tk.
1,581.00
27.50.2
200 mm dia 6 mm thick tube well pipe and blank G.I. pipe of wt. 33.45 kg per meter
can withstand minimum 700 psi hydraulic pressure
rm
Tk.
7,005.00
27.50.3
200 mm dia strainer of slot opening as per design including tagging 4 Nos. 12 mm
dia M.S. rod continuously.
27.50.3.1
200 mm dia stainless steel strainer of continuous slot having 38.36 kg per meter.
rm
Tk.
16,973.00
Item No.
181
Description of Item
Unit
Unit Rate
27.50.3.2
rm
Tk.
10,940.00
27.50.4
rm
Tk.
13,118.00
27.50.5
each
Tk.
10,977.00
27.50.6
rm
Tk.
13,409.00
27.50.7
each
Tk.
364.00
27.50.8
each
Tk.
1,977.00
27.51
Complete installation of 200 mm dia deep tube well fixtures such as expanded
top pipes, reducer, and tube well pipes, strainer, blind pipe. Pipe cap etc. Fitting and
fixing socket, welding and additional welding with fibre and placing in position with
proper size M.S. centralizer @ 3 meter c/c in strainer position including blind pipe
etc. complete as per standard practice and accepted by the Engineer.
rm
Tk.
383.00
27.52
Complete development of the tube well by suitable air compressor and pump of
suitable capacity by alternate surging and pumping until satisfactory yield, sand free
water and the turbidity condition is reached using necessary quantity of calgon and
conducting step draw down test before and after the development as per
specification and accepted by the Engineer. (Development should be started within
24 hours of completion of shrouding).
27.52.1
each
Tk.
38,647.00
27.52.2
each
Tk.
43,194.00
27.53
Pumping test of the well by designed turbine/submersible pump with supply of testing
equipments for pressure/ velocity/ discharge etc. and all materials for 72 hours
including yield drawn and recovery test etc. complete as per specification and
accepted by the Engineer.
hour
Tk.
1,044.00
27.54
each
Tk.
2,211.00
27.55
Filling of the borehole around the tube well from top of the shrouding up to the
bottom of sanitary seal by withdrawn selected soil or local clay free from any
substances harmful to pipes and health as per standard specification and accepted
by the Engineer.
rm
Tk.
43.00
Item No.
182
Description of Item
Unit
Unit Rate
Boring: Execution of 325 mm dia boring through all sorts of strata by reverse
circulation or any other approved method (Method other than reverse circulation is to
be applied only for wells deeper than 152 meter) for boring 325 mm dia vertical hole
up to designed depth and collection of soil samples at every 3 meter interval and at
every change of formation including sinking and withdrawing necessary casing pipe
and all necessary arrangements complete as per specification and accepted by the
Engineer.(Measurement will be allowed from G.L. to bottom of the blind pipe and the
rate is inclusive of the cost of extra depth of boring required for caving and siltation)
27.56.1
From 0.0 m to 50 m = 50 m
rm
Tk.
750.00
27.56.2
From 50 m to 100 m = 50 m
rm
Tk.
862.00
27.56.3
rm
Tk.
992.00
27.56.4
rm
Tk.
1,140.00
27.56.5
rm
Tk.
1,311.00
27.56.6
Beyond 250 m
rm
Tk.
1,508.00
27.57
Supplying the following tube-well fixtures and pipes conforming to standard BS1387 & BDS-1031, having chemical composition (in%) Carbon 0.17-0.25,
Manganese 0.95-1.20, Sulphur 0.060 max, Phosphorous 0.060 max, Tensile
properties: miminum Yield Strength 188 MPa, minimumTensile Strength 313 MPa
and marking for a) Manufacturer b) Material c) Wall thickness d) Nominal outside dia
e) Intended use etc. on the body of the pipe at working site as per standard practice
and accepted by the Engineer.
27.57.1
150 mm dia 6mm thick M.S. cap for blind pipe/ sand trap.
each
Tk.
1,213.00
27.57.2
50 mm dia 4.85 mm thick tube well pipe and blank G.I. pipe
rm
Tk.
851.00
27.57.3
50 mm dia strainer of slot opening as per design including tagging 4 Nos. 12 mm dia
M.S. rod continuously.
27.57.3.1
50 mm dia stainless steel strainer of continuous slot having 28.84 kg per meter.
rm
Tk.
5,782.00
27.57.3.2
rm
Tk.
5,782.00
27.57.4
rm
Tk.
2,388.00
27.57.5
each
Tk.
3,210.00
27.57.6
rm
Tk.
3,317.00
27.57.7
each
Tk.
364.00
27.57.8
each
Tk.
1,542.00
Item No.
183
Description of Item
Unit
Unit Rate
27.58
rm
Tk.
351.00
27.59
Compete development of the tube well by suitable air compressor and pump of
suitable capacity by alternate surging and pumping until satisfactory yield, sand free
water and the turbidity condition is reached using necessary quantity of calgon and
conducting step draw down test before and after the development as per
specification and accepted by the Engineer. (Development should be started within
24 hours of completion of shrouding)
27.59.1
each
Tk.
22,308.00
27.59.2
each
Tk.
25,282.00
27.60
hour
Tk.
839.00
27.61
each
Tk.
1,106.00
27.62
Filling of the borehole around the tube well from top of the shrouding up to the
bottom of sanitary seal by withdrawn selected soil or local clay free from any
substances harmful to pipes and health as per standard specification and accepted
by the Engineer.
rm
Tk.
25.00
Boring: Execution of 350 mm dia boring through all sorts of strata by reverse
circulation or any other approved method (Method other than reverse circulation is to
be applied only for wells deeper than 152 meter) for boring 350 mm dia vertical hole
up to designed depth and collection of soil samples at every 3 meter interval and at
every change of formation including sinking and withdrawing necessary casing pipe
and all necessary arrangements complete as per specification and accepted by the
Engineer. (Measurement will be allowed from G.L. to bottom of the blind pipe and the
rate is inclusive of the cost of extra depth of boring required for caving and siltation)
27.63.1
From 0.0 m to 50 m = 50 m
rm
Tk.
791.00
27.63.2
From 50 m to 100 m = 50 m
rm
Tk.
910.00
27.63.3
rm
Tk.
1,047.00
27.63.4
rm
Tk.
1,204.00
27.63.5
rm
Tk.
1,384.00
Item No.
184
Description of Item
27.63.6
Beyond 250 m
27.64
Supplying the following tube-well fixtures and pipes conforming to standard BS1387 & BDS-1031, having chemical composition (in%) Carbon 0.17-0.25,
Manganese 0.95-1.20, Sulphur 0.060 max, Phosphorous 0.060 max, Tensile
properties: miminum Yield Strength 188 MPa, minimumTensile Strength 313 MPa
and marking for a) Manufacturer b) Material c) Wall thickness d) Nominal outside dia
e) Intended use etc. on the body of the pipe at working site as per standard practice
and accepted by the Engineer.
27.64.1
150 mm dia 6mm thick M.S. cap for blind pipe/ sand trap.
27.64.2
75 mm dia 4.85 mm thick tube well pipe and blank G.I. pipe
27.64.3
75 mm dia strainer of slot opening as per design including tagging 4 Nos. 12 mm dia
M.S. rod continuously.
27.64.3.1
Unit
Unit Rate
rm
Tk.
1,592.00
each
Tk.
1,209.00
rm
Tk.
1,328.00
75 mm dia stainless steel strainer of continuous slot having 28.84 kg per meter.
rm
Tk.
7,753.00
27.64.3.2
rm
Tk.
7,753.00
27.64.4
rm
Tk.
5,167.00
27.64.5
each
Tk.
3,210.00
27.64.6
each
Tk.
3,317.00
27.64.7
each
Tk.
364.00
27.64.8
rm
Tk.
1,542.00
27.65
rm
Tk.
341.00
27.66
Complete development of the tube well by suitable air compressor and pump of
suitable capacity by alternate surging and pumping until satisfactory yield, sand free
water and the turbidity condition is reached using necessary quantity of calgon and
conducting step draw down test before and after the development as per
specification and accepted by the Engineer. (Development should be started within
24 hours of completion of shrouding)
27.66.1
each
Tk.
28,390.00
27.66.2
each
Tk.
32,175.00
Item No.
185
Description of Item
Unit
Unit Rate
27.67
hour
Tk.
897.00
27.68
each
Tk.
1,342.00
27.69
Filling of the borehole around the tube well from top of the shrouding up to the
bottom of sanitary seal by withdrawn selected soil or local clay free from any
substances harmful to pipes and health as per standard specification and accepted
by the Engineer.
rm
Tk.
29.00
Boring: Execution of 400 mm dia boring through all sorts of strata by reverse
circulation or any other approved method (Method other than reverse circulation is to
be applied only for wells deeper than 152 meter) for boring 400 mm dia vertical hole
up to designed depth and collection of soil samples at every 3 meter interval and at
every change of formation including sinking and withdrawing necessary casing pipe
and all necessary arrangements complete as per specification and accepted by the
Engineer. (Measurement will be allowed from G.L. to bottom of the blind pipe and the
rate is inclusive of the cost of extra depth of boring required for caving and siltation)
27.70.1
From 0.0 m to 50 m = 50 m
rm
Tk.
833.00
27.70.2
From 50 m to 100 m = 50 m
rm
Tk.
958.00
27.70.3
rm
Tk.
1,102.00
27.70.4
rm
Tk.
1,267.00
27.70.5
rm
Tk.
1,457.00
27.70.6
Beyond 250 m
rm
Tk.
1,676.00
27.71
Supplying the following tube-well fixtures and pipes conforming to standard BS1387 & BDS-1031, having chemical composition (in%) Carbon 0.17-0.25,
Manganese 0.95-1.20, Sulphur 0.060 max, Phosphorous 0.060 max, Tensile
properties: miminum Yield Strength 188 MPa, minimumTensile Strength 313 MPa
and marking for a) Manufacturer b) Material c) Wall thickness d) Nominal outside dia
e) Intended use etc. on the body of the pipe at working site as per standard practice
and accepted by the Engineer.
27.71.1
Supplying 150 mm 6mm thick M.S. cap for blind pipe/ sand trap.
each
Tk.
1,213.00
27.71.2
Supplying 100 mm dia 6 mm thick tube well pipe and blank G.I. pipe
rm
Tk.
1,780.00
27.71.3
100 mm dia strainer of slot opening as per design including tagging 4 Nos. 12 mm
dia M.S. rod continuously.
186
Item No.
Description of Item
Unit
Unit Rate
27.71.3.1
Supplying 100 mm dia stainless steel strainer of continuous slot having 28.84 kg per
meter.
rm
Tk.
6,994.00
27.71.3.2
Supplying 100 mm dia 2.5 mm thick stainless steel bridge type strainer
rm
Tk.
6,994.00
27.71.4
rm
Tk.
5,626.00
27.71.5
each
Tk.
3,631.00
27.71.6
rm
Tk.
3,992.00
27.71.7
each
Tk.
210.00
27.71.8
Supplying 200 mm dia M.S. cap of 6 mm thick for housing pipe covering.
each
Tk.
2,150.00
27.72
rm
Tk.
383.00
27.73
Complete development of the tube well by suitable air compressor and pump of
suitable capacity by alternate surging and pumping until satisfactory yield, sand free
water and the turbidity condition is reached using necessary quantity of calgon and
conducting step draw down test before and after the development as per
specification and accepted by the Engineer. (Development should be started within
24 hours of completion of shrouding)
27.73.1
each
Tk.
35,123.00
27.73.2
each
Tk.
39,806.00
27.74
hour
Tk.
939.00
27.75
each
Tk.
1,579.00
27.76
Filling of the borehole around the tube well from top of the shrouding up to the
bottom of sanitary seal by withdrawn selected soil or local clay free from any
substances harmful to pipes and health as per standard specification and accepted
by the Engineer.
rm
Tk.
32.00
Supplying and sinking 40 mm dia water grade uPVC tube well pipe having wall
thickness 2.5 mm to 3.0 mm including trial boring and with all necessary fittings as
required etc. all complete and accepted by the Engineer.
27.77.1
rm
Tk.
152.00
27.77.2
rm
Tk.
273.00
Item No.
187
Description of Item
Unit
Unit Rate
27.78
Supplying and sinking 3 m long uPVC strainer with all necessary fittings as
required etc. complete and accepted by the Engineer.
each
Tk.
486.00
27.79
Supplying, fitting and fixing No. 6 pump for 40 mm dia tube well with all
necessary fittings including 0.61 m long 40 mm dia G.I. Pipe etc. all complete as per
accepted by the Engineer.
each
Tk.
931.00
27.80
Construction of platform of size 1.4 m x 1.0 m and outlet drain up to1 meter long,
as per drawing with 75 mm thick cement concrete of f'c min17MPa with brick chips
and cement content relates to 1:2:4, over a brick flat soling and providing 125 mm x
75mm brick band in 1:6 all around, including finished with 12 mm thick cement
plaster in 1:4 followd by neat cement finishing all complete and accepted by the
Engineer.
each
Tk.
4,552.00
Supplying and sinking uPVC, uPVC tube well pipe, strainer including trial boring
having density 1350 kg/m3, opacity 0.2% of visible light as per ISO 7686, minimum
required strength 25 MPa conforming to BDS-1:2013, 4.4.1, 4.4.2 with all necessary
fittings as required etc. all complete and accepted by the Engineer.
27.81.1
rm
Tk.
405.00
27.81.2
rm
Tk.
225.00
27.81.3
each
Tk.
436.00
27.82
Supplying, fitting and fixing deep set tube well pump (Hand set) with all necessary
fittings as required such as No. 6 pump, 50 mm dia G.I. pipe 0.61 m long, 50 mm x
40 mm reducing socket, 40 mm dia pipe Nipple 1.22 m long cylinder, Tie foot ball, tie
plunger, 3 Nos. 10 mm dia socket, 4 Nos. 10mm dia nuts, 5 Nos. end threaded 10
mm dia M.S. rod 3 m long, necessary quantity of solution and tape etc. complete and
accepted by the Engineer.
each
Tk.
5,808.00
Item No.
188
Description of Item
Unit
Unit Rate
Unit
Rate
Description of Item
PART-A (LOW PRESSURE LINE)
28.1
Pipe line installation: Installation of 50 psi, APl, 5L, Grade-B, ERW Natural pipe line
for supplying Titas Gas including, supplying, fitting, fixing and laying different sizes
M.S. pipes with necessary tape and primer including. cutting trenches (450 x 910
mm) in all kinds of soil, cleaning, cutting, applying coal-tar, wrapping the pipes and
back filling the trenches, excavating earth including. leveling, dressing and removing
excess earth in all respect as per specification of Titas Gas T and D Co. Ltd. and
accepted by the Engineer.[Rate is excluding the cost of welding and back filling with
sand at the bottom by 300 mm in thick (compacted)]
(Pipes manufactured by National Tubes Limited under Steel & Engineeing Corporation, Ministry of
Industries, Government of Bangladesh shall be given priority)
28.1.1
75 mm N.D (88.90 mm O.D) M.S pipe, weight min 8.3 kg/m, standard test pressure
176 kg/ m2, wall thickness min 11.29 mm
rm
Tk.
1,509.00
28.1.2
50 mm N.D. (60.30 mm O.D) M.S pipe, weight min 5.44 kg/m, standard test pressure
176 kg/ m2, wall thickness min 3.91 mm
rm
Tk.
972.00
28.1.3
25 mm N.D. (33.40 mm O.D) M.S pipe weight min 2.50 kg/m, standard test pressure
50 kg/ m2, wall thickness min 3.38 mm
rm
Tk.
728.00
28.1.4
20 mm N.D. (26.70 mm O.D) M.S pipe weight min 1.68 kg/m, standard test pressure
50 kg/ m2, wall thickness min 2.87 mm
rm
Tk.
418.00
28.2
Back filling the trenches with sand (F.M 0.8) in 150 mm layer, compaction each
layer up to finished level as per standard practice and accepted by the Engineer.
cum
Tk.
644.00
28.3
Providing Butt welded joints with pipes to Tees, Elbows, Saddles, end caps etc
above or below ground including. cutting and V-leveling in each end of the pipe,
grinding by machine etc. complete as per specification of Titas Gas T and D C Ltd.
and accepted by the Engineer.
28.3.1
each
Tk.
166.00
28.3.2
each
Tk.
141.00
28.3.3
each
Tk.
110.00
28.3.4
each
Tk.
94.00
28.4
Supplying, fitting and fixing the following materials including carriage to the work site
from Titas Gas Store as per specification of Titas Gas (T and D) Co. Ltd. and
accepted by the Engineer. (Rate is excluding the cost of welding)
28.4.1
each
Tk.
263.00
28.4.2
each
Tk.
292.00
28.4.3
each
Tk.
178.00
Item No.
189
Description of Item
Unit
Unit Rate
28.4.4
50 mm x 90 Elbow
each
Tk.
226.00
28.4.5
25 mm x 90 Elbow
each
Tk.
77.00
28.4.6
50 mm x 25 mm 45 Elbow
each
Tk.
106.00
28.4.7
50 mm x 25 mm Reducer.
each
Tk.
116.00
28.4.8
20 mm plug, Socket
each
Tk.
268.00
28.4.9
50mm X 20 mm saddle
each
Tk.
236.00
28.4.10
each
Tk.
109.00
28.4.11
each
Tk.
98.00
28.5
Supplying, welding, fitting and fixing of different sizes Valve Tee/ Service Tee to
connect the pipe line with the Titas Gas Main pipe line etc. all complete in all respect
as per specification of Titas Gas T and D Co. Ltd. approved and accepted by the
Engineer.
28.5.1
each
Tk.
20,427.00
28.5.2
50 mm x 25 mm Valve Tee
each
Tk.
2,470.00
28.5.3
25 mm x 25 mm Service Tee
each
Tk.
3,475.00
28.5.4
50 mm x 25 mm Service Tee
each
Tk.
4,836.00
28.6
Supplying, fitting and fixing in position different dia I/F (Insulated Flange) etc .all
complete in all respect as per specification of Titas Gas T and D Co. Ltd. approved
and accepted by the Engineer. 50 mm N.D. (60.30 mm O.D) Insulation Flange.
each
Tk.
6,609.00
28.7
each
Tk.
63,844.00
28.8
Testing and purging the pipe lines properly as per specification of Titas Gas T and
D Co. Ltd. and accepted by the Engineer.
rm
Tk.
24.00
28.9
Supplying, fitting and fixing ball valve class 150 RF including supplying of 2 Nos.
flange along with necessary nuts and bolts welding the flange etc. all complete in all
respect as per specification of Titas Gas T and D Co. Ltd. approved and accepted by
the Engineer
28.9.1
each
Tk.
15,511.00
28.9.2
each
Tk.
10,243.00
28.10
Cutting permanent pucca (rigid/flexible) road and mending good the damages
etc. all complete in all respect and accepted by the Engineer.
Item No.
190
Description of Item
Unit
Unit Rate
28.10.1
Bituminous Road
sqm
Tk.
576.00
28.10.2
R.C.C. Road
sqm
Tk.
861.00
28.11.1
20 mm N.D
rm
Tk.
326.00
28.11.2
12 mm N.D.
rm
Tk.
302.00
28.12
Supplying, fitting and fixing in position different dia one-way brass stop cock (best
quality and heavy type) etc. complete in all respect as per specification of Titas Gas
T and D Co. Ltd. approved and accepted by the Engineer.
28.12.1
12 mm x 6 mm N.D.
each
Tk.
229.00
28.12.2
20 mm x 20 mm N.D.
each
Tk.
367.00
28.13
Testing and purging the house line properly as per specifications Titas Gas T and
D Co. Ltd. and accepted by the Engineer.
rm
Tk.
16.00
Item No.
191
Description of Item
Unit
Unit Rate
Description of Item
Unit
Rate
29.1
Supplying anti-termite chemicals named DURS BAN 20 EC and mixing the same
with pure water in required proportion (For DURSBAN 20 EC I Ltd. in 19 liters of
pure water) and spraying the emulsified mixture @ 5 liters per square meter of soil
surface by chemical sprayer or by any other means to the sides and bottom of the
foundation trench and over plinth filling or floor bed accepted by the Engineer.
sqm
Tk.
204.00
29.2
Extra cost for supplying anti termite chemicals named DURS BAN 20 EC and
mixing the same with pure water as per specification in item No. 1 and using the
same emulsified water as mixing water in cement-sand mortar of brick works in
foundation and up to plinth and accepted by the Engineer.
cum
Tk.
1,501.00
29.3
Supplying anti-termite chemicals named DURS BAN 20 EC and mixing the same
with pure water as per specification in item No. 1 and spraying the emulsified mixture
with hand sprayer over both outside and inside back fill in foundation trenches
@ 7.50 liters per sqm of the vertical surface area of the foundation wall accepted by
the Engineer. (The maximum depth of the back fill to be treated is 500 mm. and the
measurement for depth should not be given more than 500 mm)
sqm
Tk.
305.00
29.4
Per
hole
Tk.
39.00
29.5
rm
Tk.
202.00
29.6
cum
Tk.
15.00
29.7
sqm
Tk.
148.00
Item No.
192
Description of Item
Unit
29.8
Per
board
Tk.
235.00
29.9
Destruction of termite nest around an infested building, tree stumps in lawn with the
treatment of DURS BAN 20 EC by excavation of soil in affected area up to a depth of
1.5 meter, mixing the DURS BAN 20 EC solution to be mixed with water in 1:19 ratio
with the soil and laying the same in same place etc. all complete as per direction
including. cost of all materials and chemicals etc. complete and accepted by the
Engineer.
each
nest
Tk.
1,474.00
Unit Rate
Item No.
193
Description of Item
Unit
Unit Rate
Unit
Rate
Description of Item
30.1
70 mm thick partition wall excluding plaster thickness with Concrete Hollow block
having compressive strength of 4.14~5N/mm2 of size (390 x 70 x 190) mm in
compliance with ASTM C129, fairly uniform thickness and texture and individual
Block shell thickness should not be less than 16 mm, water absorption not more than
7%, laying with 8-10 mm thick mortar (with admixture) of cement, lime and sand
in ratio 1:1:6 (sand not less than 1.2 F.M) filling the interstices with mortar and
making bond with connecting walls including necessary scaffolding and curing for
min 3 (three) days on mortar joints by jute /brush in wet, followed by impervious /wet
covering for another 4 (four) days etc all complete and accepted by the Engineer.
30.1.1
Ground floor
sqm
Tk.
598.00
30.1.2
sqm
Tk.
24.82
30.1.3
Add for each addl floor for 6th floor to 9th floor
sqm
Tk.
33.10
30.1.4
Add for each addl floor for 10th floor and above
sqm
Tk.
41.37
30.2
70 mm thick partition wall excluding plaster thickness with Concrete Hollow block
having compressive strength of 4.14~5N/mm2 of size (390 x 70 x 190) mm
compliance with ASTM C129, thickness of individual Block shell should not be less
than 16 mm, water absorption not more then 7 % lying with 8 to 10 mm thick mortar
(with admixture) of cement and sand in ratio 1:6 (sand not less than 1.2 F.M)
filling the interstices with mortar and making bond with connecting walls including
necessary scaffolding and curing for min 3(three) days on mortar joints by jute/brush
in wet, followed by impervious/wet covering for another 4 (four) days etc all complete
and accepted by the Engineer.
30.2.1
Ground floor
sqm
Tk.
578.00
30.2.2
sqm
Tk.
24.82
30.2.3
Add for each addl floor for 6th floor to 9th floor
sqm
Tk.
33.10
30.2.4
Add for each addl floor for 10th floor and above
sqm
Tk.
41.37
30.3
30.3.1
Ground floor
sqm
Tk.
654.00
30.3.2
sqm
Tk.
24.82
Item No.
194
Description of Item
Unit
Unit Rate
30.3.3
Add for each addl floor for 6th floor to 9th floor
sqm
Tk.
33.10
30.3.4
Add for each addl floor for 10th floor and above
sqm
Tk.
41.37
30.4
90 mm thick partition wall with Concrete Hollow block having compressive strength
of 4.14~5N/mm2 of size (390 x 90 x 190) mm in compliance with ASTM C129,
thickness of individual Block shell should not be less than 16 mm, water absorption
not more than 7%, lying with specified mortar (with admixture) of cement, and
sand in ratio 1:6 (sand not less than 1.2 F.M), filling the interstices with mortar and
making bond with connecting walls including necessary scaffolding and curing for
min 3 (three) days on mortar joints by jute /brush in wet, followed by impervious /wet
covering for another 4 (four) days curing etc. all complete and accepted by the
Engineer.
30.4.1
Ground floor
sqm
Tk.
634.00
30.4.2
sqm
Tk.
24.82
30.4.3
Add for each addl floor for 6th floor to 9th floor
sqm
Tk.
33.10
30.4.4
Add for each addl floor for 10th floor and above
sqm
Tk.
41.37
30.5
140 mm thick load bearing wall with Concrete Hollow block having compressive
strength of 13~18N/mm2 of size (390 x 140 x 190) mm compliance with ASTM C90,
thickness of individual Block shell should not be less then 25 mm, water absorption
not more than 7%, laying with mortar (with admixture) of cement, lime and sand
in ratio 1:1:6 (sand not less than 1.2 F.M), filling the interstices with mortar and
making bond with connecting walls including necessary scaffolding and curing for
min 3 (three) days on mortar joints by jute /brush in wet, followed by impervious /wet
covering for another 4 (four) days etc all complete and accepted by the Engineer.
30.5.1
Ground floor
sqm
Tk.
915.00
30.5.2
sqm
Tk.
33.10
30.5.3
Add for each addl floor for 6th floor to 9th floor
sqm
Tk.
41.37
30.5.4
Add for each addl floor for 10th floor and above
sqm
Tk.
49.65
30.6
140 mm thick partition wall with Concrete Hollow block having compressive
strength of 4.14~5N/mm2 of size (390 x 140 x 190) mm in compliance with ASTM
C129, thickness of individual Block shell should not be less than 16 mm, water
absorption not more than 7%, laying with specified mortar (with admixture) of
cement and sand in ratio 1:6 (sand not less than 1.2 F.M), filling the interstices with
mortar and making bond with connecting walls including necessary scaffolding and
curing for min 3 (three) days on mortar joints by jute /brush in wet, followed by
impervious /wet covering for another 4( four) days curing etc all complete and
accepted by the Engineer.
30.6.1
Ground floor
sqm
Tk.
888.00
30.6.2
sqm
Tk.
33.10
30.6.3
Add for each addl floor for 6th floor to 9th floor
sqm
Tk.
41.37
30.6.4
Add for each addl floor for 10th floor and above
sqm
Tk.
49.65
Item No.
195
Description of Item
Unit
Unit Rate
30.7
140 mm thick load bearing wall with Concrete Hollow block having compressive
strength of 13~18N/mm2 of size (390 x 140 x 190) mm compliance with ASTM C90,
thickness of individual Block shell should not be less then 25 mm, water absorption
not more than 7%, laying with mortar (with admixture) of cement, lime and sand
in ratio 1:1:6 (sand not less than 1.2 F.M), filling the interstices with mortar and
making bond with connecting walls including necessary scaffolding and curing for
min 3 (three) days on mortar joints by jute /brush in wet, followed by impervious /wet
covering for another 4 (four) days etc all complete and accepted by the Engineer.
30.7.1
Ground floor
sqm
Tk.
1,144.00
30.7.2
sqm
Tk.
33.10
30.7.3
Add for each addl floor for 6th floor to 9th floor
sqm
Tk.
41.37
30.7.4
Add for each addl floor for 10th floor and above
sqm
Tk.
49.65
30.8
140 mm thick load bearing wall with Concrete Hollow block having compressive
strength of 13~18 N/mm2 of size (390 x140 x 190) mm in compliance with ASTM
C90, thickness of individual Block shell should not be less than 25 mm, water
absorption not more than 7%, laying with mortar (with admixture) of cement and
sand in ratio 1:6 (sand not less than 1.2 F.M), filling the interstices with mortar and
making bond with connecting walls including necessary scaffolding and curing for
min 3 (three) days on mortar joints by jute /brush in wet, followed by impervious /wet
covering for another 4 (four) days etc all complete and accepted by the Engineer.
(rate is excluding the cost of grouting and reinforcement)
30.8.1
Ground floor
sqm
Tk.
1,117.00
30.8.2
sqm
Tk.
33.10
30.8.3
Add for each addl floor for 6th floor to 9th floor
sqm
Tk.
41.37
30.8.4
Add for each addl floor for 10th floor and above
sqm
Tk.
49.65
30.9
190 mm thick load bearing wall with Concrete Hollow block having compressive
strength of 4.14~5 N/mm2 of size (390 x 190 x 190) mm compliance with ASTM C90,
thickness of individual Block shell should not be less than 25 mm, water absorption
not more than 7%, laying with mortar (with admixture) of cement, lime and sand
in ratio 1:1:6 (sand not less than 1.2 F.M), filling the interstices with mortar and
making bond with connecting walls including necessary scaffolding and curing for
min 3 (three) days on mortar joints by jute /brush in wet, followed by impervious /wet
covering for another 4 (four) days etc all complete and accepted by the Engineer.
(rate is excluding the cost of grouting and reinforcement)
30.9.1
Ground floor
sqm
Tk.
1,318.00
30.9.2
sqm
Tk.
41.37
30.9.3
Add for each addl floor for 6th floor to 9th floor
sqm
Tk.
49.65
30.9.4
Add for each addl floor for 10th floor and above
sqm
Tk.
57.92
Item No.
196
Description of Item
Unit
Unit Rate
30.10
190 mm thick load bearing wall with Concrete Hollow block having compressive
strength of 13~18 N/mm2 of size (390 x 190 x 190) mm in compliance with ASTM
C90, thickness of individual block shell should not be less than 25 mm, water
absorption not more than 7%, laying with mortar (with admixture) of cement and
sand in ratio 1:6 (sand not less than 1.2 F.M), filling the interstices with mortar and
making bond with connecting walls including necessary scaffolding and curing for
min 3 (three) days on mortar joints by jute /brush in wet, followed by impervious /wet
covering for another 4 (four) days etc all complete and accepted by the Engineer.
(Rate is excluding cost of grouting and reinforcement)
30.10.1
Ground floor
sqm
Tk.
1,293.00
30.10.2
sqm
Tk.
41.37
30.10.3
Add for each addl floor for 6th floor to 9th floor
sqm
Tk.
49.65
30.10.4
Add for each addl floor for 10th floor and above
sqm
Tk.
57.92
30.11
Supplying, carrying and placing of (600 x 200 x 150) mm concrete ceiling block on
properly leveled shutter accepted by the Engineer.
30.11.1
Ground floor
each
Tk.
89.00
30.11.2
each
Tk.
3.08
30.11.3
Add for each addl floor for 6th floor to 9th floor
each
Tk.
3.84
30.11.4
Add for each addl floor for 10th floor and above
each
Tk.
4.61
30.12
Supplying, carrying and placing of (600 x 200 x200) mm concrete ceiling block on
properly leveled shutter accepted by the Engineer
30.12.1
Ground floor
each
Tk.
120.00
30.12.2
each
Tk.
3.84
30.12.3
Add for each addl floor for 6th floor to 9th floor
each
Tk.
6.92
30.12.4
Add for each addl floor for 10th floor and above
each
Tk.
8.07
30.13
30.13.1
Ground floor
sqm
Tk.
203.00
30.13.2
sqm
Tk.
11.03
30.13.3
Add for each addl floor for 6th floor to 9th floor
sqm
Tk.
16.55
30.13.4
Add for each addl floor for 10th floor and above
sqm
Tk.
22.07
Item No.
197
Description of Item
Unit
Unit Rate
30.14.1
Supplying and placing of approx. 60 mm thick grey Uni-Block paving for walk way
having compressive strength of 15 N/mm2 on compacted sand bed of 50 mm on
stabilized soil base, and filling all interstices with sand, cleaning etc. accepted by the
Engineer.
sqm
Tk.
799.00
30.14.2
Supplying and placing of approx. 60 mm thick coloured Uni-Block for paving walk
way having compressive strength of 15 N/mm2 on compacted sand bed of 50 mm on
stabilized soil base, and filling all interstices with sand, cleaning etc. accepted by the
Engineer.
sqm
Tk.
1,019.00
30.15.1
Supplying and placing of 60 mm thick grey Uni-Block for paving foot-path, major
walk way, car porch having compressive strength of 49 N/mm2 on compacted sand
bed of 50 mm on stabilized soil base, and filling all interstices with sand, cleaning
etc. accepted by the Engineer.
sqm
Tk.
1,081.00
30.15.2
sqm
Tk.
1,155.00
30.16.1
Supplying and placing of 80 mm grey Uni-Block for paving Heavy Trafic areas,
Roads Rounds Abuts, Industrial Yards etc having compressive strength of 49
N/mm2 on compacted sand bed of 50 mm on stabilized soil base, and filling all
interstices with sand, cleaning etc. accepted by the Engineer.
sqm
Tk.
1,330.00
30.16.2
Supplying and placing of 80 mm thick coloured Uni-Block for paving Heavy trafic
areas, road, industrial yard etc having compressive strength of 49 N/mm2 on
compacted sand bed of 50 mm on stabilized soil base, and filling all interstices with
sand, cleaning etc. accepted by the Engineer.
sqm
Tk.
1,590.00
30.17.1
sqm
Tk.
1,399.00
30.17.2
sqm
Tk.
1,605.00
30.18.1
Supplying and placing of grey engraved cement concrete tiles (250 x 250 mm) in
size having minimum thickness 24 mm over 12 mm sand cement mortar (4:1) each
at a distance of 6 mm apart and filling the joints with cement sand mortar (1:4)
including raking out joints and cutting the tiles to required sizes wherever necessary
with high class recessed pointing, cleaning and washing of sand, curing for min 3
(three) days on mortar joints by jute /brush in wet, followed by impervious /wet
covering for another 4 (four) days etc. all complete and accepted by the Engineer.
30.18.1.1
Ground floor
sqm
Tk.
919.00
30.18.1.2
sqm
Tk.
31.28
30.18.1.3
Add for each addl floor for 6th floor to 9th floor
sqm
Tk.
39.10
30.18.1.4
Add for each addl floor for 10th floor and above
sqm
Tk.
46.92
Item No.
198
Description of Item
Unit
Unit Rate
30.18.2
Supplying and placing of coloured engraved cement concrete tiles (250 x 250
mm) in size having minimum thickness 24 mm over 12 mm sand cement mortar (4:1)
each at a distance of 6 mm apart and filling the joints with cement sand mortar (1:4)
including raking out joints and cutting the tiles to required sizes wherever necessary
with high class recessed pointing, cleaning and washing of sand, curing for min 3
(three) days on mortar joints by jute /brush in wet, followed by impervious /wet
covering for another 4 (four) days etc. all complete and accepted by the Engineer.
30.18.2.1
Ground floor
sqm
Tk.
1,035.00
30.18.2.2
sqm
Tk.
31.28
30.18.2.3
Add for each addl floor for 6th floor to 9th floor
sqm
Tk.
39.10
30.18.2.4
Add for each addl floor for 10th floor and above
sqm
Tk.
46.92
30.19.1
215 mm thick wall (excluding plaster thickness) with 215 x 100 x 65 mm concrete
solid block having minimum compressive strength of 21 N/mm2 of size with 6 mm
thick cement sand mortar in 1:6 in superstructure including racking out the joints,
filling the interstices with mortar and making bond with connecting walls including
necessary scaffolding and curing for min. 3 (three) days on mortar joint by jute/ brush
in wet followed by impervious covering for another 4 (four) days etc. all complete and
accepted by the Engineer.
30.19.1.1
Ground floor
sqm
Tk.
1,791.00
30.19.1.2
sqm
Tk.
31.28
30.19.1.3
Add for each addl floor for 6th floor to 9th floor
sqm
Tk.
39.10
30.19.1.4
Add for each addl floor for 10th floor and above
sqm
Tk.
46.92
30.19.2
100 mm thick wall (excluding plaster thickness) with 215 x 100 x 65 mm concrete
solid block having minimum compressive strength of 21N/mm2 of size with 6 mm
thick cement sand mortar in 1:6 in superstructure including racking out the joints,
filling the interstices with mortar and making bond with connecting walls including
necessary scaffolding and curing for min. 3 (three) days on mortar joint by jute/ brush
in wet followed by impervious covering for another 4 (four) days etc. all complete and
accepted by the Engineer.
30.19.2.1
Ground floor
sqm
Tk.
909.00
30.19.2.2
sqm
Tk.
31.28
30.19.2.3
Add for each addl floor for 6th floor to 9th floor
sqm
Tk.
39.10
30.19.2.4
Add for each addl floor for 10th floor and above
sqm
Tk.
46.92
30.20.1
38 mm thick Grey cladding work in facing on superstructure with (200 x 90x 38)
mm size concrete clad pested with 20 mm thick cement mortar (1:4) to be placed at
6 mm apart, filling the interstices with same mortar, raking out joints and cutting the
clad to required sizes wherever necessary with high class recessed pointing,
cleaning and washing of sand, necessary scaffolding, curing for min 3 (three) days
on mortar joints by jute /brush in wet, followed by impervious /wet covering for
another 4 (four) days etc. all complete for up to 4th floor accepted by the Engineer.
Item No.
199
Description of Item
Unit
Unit Rate
30.20.1.1
Ground floor
sqm
Tk.
1,337.00
30.20.1.2
sqm
Tk.
31.28
30.20.1.3
Add for each addl floor for 6th floor to 9th floor
sqm
Tk.
39.10
30.20.1.4
Add for each addl floor for 10th floor and above
sqm
Tk.
46.92
30.20.2
30.20.2.1
Ground floor
sqm
Tk.
1,136.00
30.20.2.2
sqm
Tk.
31.28
30.20.2.3
Add for each addl floor for 6th floor to 9th floor
sqm
Tk.
39.10
30.20.2.4
Add for each addl floor for 10th floor and above
sqm
Tk.
46.92
30.20.3
50 mm thick Grey cladding work in facing on superstructure with (400 x100 x 50)
mm size concrete clad pested with 20 mm thick cement mortar (1:4) to be placed at
6 mm apart, filling the interstices with same mortar, raking out joints and cutting the
clad to required sizes wherever necessary with high class recessed pointing,
cleaning and washing of sand, necessary scaffolding, curing for min 3 (three) days
on mortar joints by jute /brush in wet, followed by impervious /wet covering for
another 4 (four) days etc. all complete for up to 4th floor accepted by the Engineer.
30.20.3.1
Ground floor
sqm
Tk.
1,052.00
30.20.3.2
sqm
Tk.
31.28
30.20.3.3
Add for each addl floor for 6th floor to 9th floor
sqm
Tk.
39.10
30.20.3.4
Add for each addl floor for 10th floor and above
sqm
Tk.
46.92
30.20.4
30.20.4.1
Ground floor
sqm
Tk.
1,110.00
30.20.4.2
sqm
Tk.
31.28
30.20.4.3
Add for each addl floor for 6th floor to 9th floor
sqm
Tk.
39.10
Item No.
200
Description of Item
30.20.4.4
Add for each addl floor for 10th floor and above
30.20.5
15 mm thick Grey cladding work in facing on superstructure with (420 x 330 x 15)
mm size concrete clad pested with 20 mm thick cement mortar (1:4) to be placed at
6 mm apart, filling the interstices with same mortar, raking out joints and cutting the
clad to required sizes wherever necessary with high class recessed pointing,
cleaning and washing of sand, necessary scaffolding, curing for min 3 (three) days
on mortar joints by jute /brush in wet, followed by impervious /wet covering for
another 4 (four) days etc. all complete for up to 4th floor accepted by the Engineer.
30.20.5.1
Unit
Unit Rate
sqm
Tk.
46.92
Ground floor
sqm
Tk.
700.00
30.20.5.2
sqm
Tk.
31.28
30.20.5.3
Add for each addl floor for 6th floor to 9th floor
sqm
Tk.
39.10
30.20.5.4
Add for each addl floor for 10th floor and above
sqm
Tk.
46.92
30.20.6
30.20.6.1
Ground floor
sqm
Tk.
700.00
30.20.6.2
sqm
Tk.
31.28
30.20.6.3
Add for each addl floor for 6th floor to 9th floor
sqm
Tk.
39.10
30.20.6.4
Add for each addl floor for 10th floor and above
sqm
Tk.
46.92
30.21.1
Supplying, carrying, placing, providing (418 x 330 x 17) mm size of red colour
concrete roof tiles on pre-fixed and pre-fabricated truss and fixing each tile to the
roof members of truss accepted by the Engineer.
sqm
Tk.
68.00
30.21.2
Supplying, carrying, placing, providing (418 x 330 x 17) mm size of oriental colour
concrete roof tiles on pre-fixed and pre-fabricated truss and fixing each tile to the
roof members of truss accepted by the Engineer.
sqm
Tk.
63.00
30.21.3
Supplying, carrying, placing, providing (418 x 330 x 17) mm size of antique red
colour concrete roof tiles on pre-fixed and pre-fabricated truss and fixing each tile
to the roof members of truss accepted by the Engineer.
sqm
Tk.
68.00
30.21.4
Supplying, carrying, placing, providing (418 x 330 x 17) mm size of green colour
concrete roof tiles on pre-fixed and pre-fabricated truss and fixing each tile to the
roof members of truss accepted by the Engineer.
sqm
Tk.
73.00
30.22
Supplying, carrying, placing, providing of concrete Kerb stone size (600 x 300 x
100) mm approved and accepted by the Engineer.
sqm
Tk.
195.00
Item No.
201
Description of Item
Unit
Unit Rate
Description of Item
Unit
Rate
Per site
Tk.
9,303.00
31.2
Field visit , fixing location of bore holes citing respective coordinates in X, Y &
Z axes with respect to pre-determind datum(BM) and inspection of sampling and
samples by the Geo-tech. Expert / Engineer
Per site
Tk.
5,697.00
31.3
31.3.1
Per point
Tk.
839.00
31.3.2
Installation of boring equipment at site: for depth of water above 750 mm to 1500
mm and accepted by the Engineer.
Per point
Tk.
4,223.00
31.3.3
Per point
Tk.
5,715.00
31.4
31.4.1
Boring 100 mm dia bore-hole by wash boring method: 0 to 15 meter including the
depths for SPT operation and accepted by the Engineer.
rm
Tk.
214.00
31.4.2
rm
Tk.
235.00
31.4.3
Boring 100 mm dia bore-hole by wash boring method: 25meter to 35 meter including
the depths for SPT operation and as and accepted by the Engineer.
rm
Tk.
241.00
31.4.4
rm
Tk.
246.00
31.4.5
Boring 100 mm dia bore-hole by wash boring method: 45 meter & above including
the depths for SPT operation and accepted by the Engineer.
rm
Tk.
256.00
31.5
31.5.1
Per point
Tk.
90.00
Item No.
202
Description of Item
Unit
Unit Rate
31.5.2
Per point
Tk.
100.00
31.5.3
Per point
Tk.
108.00
31.5.4
Per point
Tk.
139.00
31.5.5
Per point
Tk.
214.00
31.6
Per
sample
Tk.
113.00
31.7
Per
sample
Tk.
97.00
31.8
Plate load test: mobilization, demobilization, arrangement of plates for loading and
all other required materials, execution of tests, recording the data, preparation and
submission of test report (if desired by S.E. Design Circle) and accepted by the
Engineer.
Per test
Tk.
19,517.00
31.9
Per site
Tk.
10,462.00
Carrying out different test on soil samples collected from the sub-soil
investigation site accepted by the Engineer.
31.10
Specific gravity
per set of
test
Tk.
150.00
31.11
Grain size Analysis of soil by Sieve and Hydrometer analysis & Specific gravity test,
And Providing ASTM Classification of Soil
per set of
test
Tk.
1,050.00
31.12
per set of
test
Tk.
113.00
31.13
per set of
test
Tk.
600.00
31.14
per set of
test
Tk.
600.00
31.15
31.15.1
per set of
test
Tk.
300.00
31.15.2
per set of
test
Tk.
300.00
31.16
per set of
test
Tk.
226.00
31.17
Void ratio
per set of
test
Tk.
750.00
31.18
per set of
test
Tk.
150.00
31.19
per set of
test
Tk.
1,126.00
31.20
per set of
test
Tk.
863.00
31.21
per set of
test
Tk.
1,200.00
Item No.
203
Description of Item
Unit
Unit Rate
31.22
per set of
test
Tk.
1,500.00
31.23
per set of
test
Tk.
3,000.00
31.24
per set of
test
Tk.
1,650.00
31.25
Shear test
31.25.1
per set of
test
31.25.1.1
per set of
test
Tk.
1,200.00
31.25.1.2
per set of
test
Tk.
1,050.00
31.25.1.3
per set of
test
Tk.
1,200.00
31.25.2
31.25.2.1
Consolidated undrained triaxial test with pore pressure for cohesive and non cohesive soil
per set of
test
Tk.
3,450.00
31.25.2.2
Consolidated undrained triaxial test without pore pressure for cohesive soil
per set of
test
Tk.
1,050.00
31.25.2.3
per set of
test
Tk.
1,500.00
31.25.2.4
per set of
test
Tk.
1,200.00
31.25.3
per set of
test
Tk.
2,100.00
31.26
per set of
test
Tk.
900.00
31.27
per set of
test
Tk.
2,250.00
31.28
per set of
test
Tk.
2,400.00
31.29
per set of
test
Tk.
2,250.00
31.30
Non-repetitive static plate load test of soil (ASTM D-1196-64, reapproved in 1977
per set of
test
Tk.
2,100.00
31.31
Compaction test
31.31.1
Standard proctor
per set of
test
Tk.
1,800.00
31.31.2
Modified proctor
per set of
test
Tk.
1,950.00
Item No.
204
Description of Item
Unit
Unit Rate
Sub - Soil investigation by exploratory borings and/ or by CPT, DCP etc. collecting
and necessary testing of samples in numbers as required for Stratification of Layers,
physical parameters of soils like Atterberg limits,Specific Gravity, Gain size
distribution(by wet seive, Hydrometer if required) ,shrinkage & swelling, Settlement ;
C - values and other Strength parameters to ascertain Bearing Capacity , Skin
friction, End bearings etc at layers of interest as per respective National/International
standards and entering all theese data & information in necessary Tables & Graphs ,
furnishing them in the form of Standard Sub-Soil Investigation Report duly signed by
competent Engineer & Exploratory Office.
31.32.1
per bore
Tk.
8,675.00
31.32.2
per bore
Tk.
9,108.00
31.32.3
per bore
Tk.
11,364.00
31.32.4
per bore
Tk.
13,637.00
31.32.5
per bore
Tk.
16,364.00
31.32.6
per bore
Tk.
19,637.00
31.32.7
per bore
Tk.
23,564.00
31.32.8
per bore
Tk.
28,277.00
31.33
Extra cost per site for Mobilization & demobilization in addition to any item
under 31.32
31.33.1
Per site
Tk.
9,303.00
31.33.2
Other than divisional city : cost in addition to item 31.33.1 for the distance from
respective divisional HQ to site.
per km
Tk.
20.00
31.34
Extra cost per bore hole , if the same is under water by more than 1.5m in depth
Tk.
4,223.00