Datasheet

OptiSwitch 906G Series - Converged L2 & L3 Service Demarcation


Product Highlights
Carrier Ethernet service demarcation
- MEF-compliant CE2.0 services
- MEF 9, MEF14, and MEF 21 compliance
Unified Master-OSTM control plane for all models
2.5Gbps rate for high-speed service offerings
- Enables service providers to offer higher speed
services without the cost of a 10GE port
Carrier-grade resiliency - sub 50ms recovery time
- ELPS G.8031 and ERPS G.8032
Hierarchical QoS for premium SLAs
End-to-end Service OAM to monitor SLAs
L1 Shaping
MPLS LER & LSR functionality
Full range of L2 and L3/IP Services
- L2 Carrier Ethernet, MPLS, MPLS-TP (*)
and IPv4/IPV6 (*) Forwarding & Routing
sFlow support for Application-Aware Networking
SyncE and IEEE1588v2 PTP Timing & Synchronization
Zero-touch provisioning with rapid service turn-up
and customer web portal
- MRVs Pro-Vision Service Provisioning and NMS
Temperature hardened models

(**)

OS906G Series
The OptiSwitch 906G series is a complete product line that comprises MEF-compliant
CE2.0 carrier-class intelligent Ethernet Demarcation service devices.
The OS906G portfolio includes 1/2 19 devices, full 19 devices with dual redundant
and pluggable power supplies, temperature hardened models, and timing &
synchronization supporting models.
The OptiSwitch 906G series was perfectly designed to converge premium L2 and L3
services into single cost effective and yet scalable unified devices.
The OS906G series enables premium manageable end-to-end Ethernet services
with extensive traffic management, performance management, and HW-based OAM
tools ensuring strict Service Level Agreements (SLAs) across optical packet switched
networks.

Applications

The OptiSwitch 906G provides Ethernet demarcation functionality for SLA-based


business Ethernet services, Ethernet mobile backhaul, including Synchronous
Ethernet and IEEE1588v2 PTP Timing & Synchronization support, and External
Ethernet Network-to-Network interfaces with end-to-end Ethernet services across
multiple service providers.

Business Ethernet Services


Mobile Backhaul Services
Carrier Ethernet enabled Cloud Services
Inter-operator E-NNI Services

WAN

LAN

4G/eNodeB
OS-906G

PS2 FAN

PS1 PWR
CONSOLE EIA-232

24

23

CONSOLE EIA-232
22

24

21

23

MGT ETH

PS2

PS1 MGT TMP FAN

10

12

14

11

13

16

18

20

22

24

15

17

19

21

23

25
10GE-XFP

RST

26
10GE-XFP

OptiSwitch
9124-410G
L
A

L
A

L
A

L
A
2

EM9005 PS/DC

27
10GE-XFP

28
10GE-XFP

EM9005 PS/AC

ADD

BITS
L

MGT ETH

S1

S2

BITS
L

MGT ETH

S1

S2

S1

PS1 PWR
CONSOLE EIA-232

S2

EXP
47 49 51 53 55 57 59 61

Metro Ethernet Network

OS-906G

PS2 FAN

BITS
L

MGT ETH

PS1 PWR
CONSOLE EIA-232

RNC/S-GW

OS-906G

PS2 FAN

CAUTION
This assembly contains
electronically sensitive
components

IN

OUT

COM

DROP
47 49 51 53 55 57 59 61

MS9-OADM8

Optical Packet
Switched Network

OS-906G

PS2 FAN

PS1 PWR
CONSOLE EIA-232

BITS
L

MGT ETH

S1

OS-906G

S2

PS2

PS1

CONSOLE EIA-232
USB HOST

10

11

13
10GE-XFP

12

TMP

14
10GE-XFP

PS2 FAN

OptiSwitch OS940

FAN

PS1 PWR
CONSOLE EIA-232

L
A

L
A

L
A

L
A
1

15
10GE-XFP

Carrier Ethernet Demarcation - UNI

- Bandwith on demand
- SLA & Performance Monitoring
Cloud Services

OS-906G

PS1 PWR
CONSOLE EIA-232

BITS
L

S1

S2

3G
Node B

Mobile Backhaul (NGN Packet Switched Network)

Operator 1

E -NNI

Operator 2

BITS
L

MGT ETH

End - to - end Service OAM

End - to - end Service OAM

PS2 FAN

MGT ETH

16
10GE-XFP

S1

S2

Carrier Ethernet enabled


Cloud Connectivity

End - to - end Service OAM

Inter-operator - E-NNI

For inter-provider connecting points, the OS906G serves as a demarcation device at carrier-to-carrier on-net locations and provides External
Ethernet Network-to-Network interfaces (E-NNI) that separate two different service provider networks. In such a deployment scenario, the
OS906G enables Ethernet service delivery over multiple carrier transport networks with end-to-end visibility and control.
The OS906G series includes 4 basic models (noted in the ordering information section on the last page):
1. 19 1U device with internal AC/DC power supply and optional redundant and external AC/DC power supply
2. Full 19 1U device with dual pluggable & redundant AC or DC power supplies
3. Temperature-hardened (-40C to 65C) full 19 1U device with dual pluggable & redundant AC or DC power supplies (future HW option)
4. Temperature-hardened (-40C to 65C), SyncE and IEEE1588v2 (Master *, Slave, BC) supporting devices. Full 19 1U with dual pluggable &
redundant AC/DC power supply.
(*) Future Software release
(**) For selected models
Not sure which solution best meets your needs? Visit www.mrv.com or e-mail us at [email protected]

VPN Services & Protection


Compliant to MEF Ethernet Virtual Circuit (EVC), the OS906G offers the following 3 types of VPN service:
1. Layer 1 Optical VPN a cross-connect mode without MAC address learning
2. Layer 2 VPN VLAN-based tunneling, Q-in-Q stacking, swapping, or mapping services
3. Layer 2.5 VPN a label-based MPLS VC for direct connection into MPLS domains or H-VPLS MTU-s
All the above VPN services can be fully protected using port redundancy, dual-homing, and/or ring topology with a recovery time less than 50 ms.
In addition to L2 VPN, the OS900 offers integrated IP router services to save on cost of an external router, and provides a single
demarcation platform for managed L2 VPN and IP services.

Advanced Traffic Management


The OS906G series enables a value-added network infrastructure, with end-to-end per flow QoS.
It supports full CoS and QoS (MEF 14 model) including classification of flows, rate limiting, shaping, WFQ scheduling, and strict priority
for lower delay/jitter and guaranteed throughput in real-time applications. In addition, it enables dynamic/adaptive buffer pools to
prevent bursty traffic starvation and ensure effectiveness of queuing resources.
For network convergence applications that have a clear boundary between the customers and the carriers networks, CoS layers
(802.1p, IP ToS, and MPLS EXP bits) can be mapped/marked to preserve priorities or mapped into predefined protection profiles
preconfigured by the provider.

Hierarchical QoS CoS-Aware Rate Limit


Defining premium SLAs is a key requirement for service differentiation.
The OS906G enables traffic management based on innovative CoS-aware rate limit to dynamically reuse bandwidth profiles. Dynamic
QoS allows sharing of defined rate limited flows controlled by an aggregate profile applied to a user network interface or an EVC.
In the new service offering, the consolidated real-time, high-priority and best effort data require different rates and marked Class
of Service (CoS). Dynamic QoS helps to share/borrow the bandwidth allocated for real-time or high priority applications at a time
when these services are not active. Such an offering contributes to a more efficient way of provisioning bandwidth at the access/
demarcation interfaces of the network without complex configuration settings at the aggregation layer.

End-to-end OAM - IEEE802.1ag , ITU-T Y.1731, IP-SLA & RFC2544, ITU-T Y.1564 Service turn-up (*)
The OS906G series incorporates connectivity, discovery, and fault management along with performance statistics of delay, jitter, and frame
loss for demarcation and intermediate points of service. OS906G series offers hardware-based SLA measurment tools with nanosecond
accuracy.
The OS906G demarcation series is a standard-compliant and interoperable OAM solution that enables:
1. End-to-end Connectivity Fault Management per IEEE802.1ag
2. End-to-end Performance Measurement per ITU Y.1731
3. IP SLA with HW-based time stamping (IP-VPN measurements)
4. RFC2544 Layer 2 and 3 testing at up to 1Gbps rate
5. MEF SOAM per MEF10.2
6. Y.1563 Service Availability Measurement based on SLM/SLR
7. Y.1564 service turn-up (*)

Per-service Performance Monitoring


The OS906G offers real-time and history reporting on various service performance metrics, including port/VPN-EVC utilization,
transmission errors, as well as QoS threshold exceptions.
Each service can be tracked for statistical information to help in baselining and troubleshooting traversing services. This capability
enables users to verify service guarantees and increase network reliability by validating network performance. Performance
monitoring uses pro-active monitoring to regulate traffic in a continuous, reliable, and predictable manner so as to enable
measurement of network performance and health.

End-to-end Service Provisioning and OAM


Pro-Vision is MRVs carrier-class service provisioning & management
platform that offers service providers a wide range of applications &
tools to fully manage and control large-scale MEF compliant Carrier
Ethernet based data, voice, and video services.

Network Operation Center

Pro-Vision R

XML OSS
SMN

SMN

)elbapac NALVSI( tiBagiG : epyT


edoMitluM-scitpOrebiF

tmgM rrEtmX XR XT

: epyT lacisyhP

pU si kniL

sutatS kniL

ffO si eerTpS

eerT gninnapS

delbanE

troP lla

etatS troP

kniL cF xR

32
3
3

32

rebmuN troP
rebmuN tolS
rebmuN troP tolS edisnI

B514C5A10200 sserddA CAM


delbasiD

troP lla

xelpud _lluF

troP lla

lortnoC wolF
edoM xelpuD

sailA

gnitnuoccA
verP

txeN

shparG scitsitatS
agiGecrof

troP lla

edoM NALVSI

troP lla

deepS troP
edoM NALVSI

eerT gninnapS
pleH

stnC stroP
scitsitatS NOMR
KO

lecnaC

SMN

541hn : )stroP( shparG scitsitatS stroP


sraB eniL mdpS

SNMP

ylpitluM
1

6378016411

5909708

1
1
1
1

eliT

0
0

setyB tupnI
stekcaP tsacinU tupnI
stekcaP tsacinU-noN tupnI
stekcaP dedracsiD tupnI

stekcaP rorrE tupnI

stekcaP locotorP nwonknU tupnI

32
32
32

65694

59844

stekcaP rorrE tuptuO

32

)stekcap( htgneL eueuQ tuptuO

32

setyB tuptuO
stekcaP tsacinU tuptuO
stekcaP tsacinU-noN tuptuO
stekcaP dedracsiD tuptuO

teseR

SMN

32
32
32

32
32
32
32

:sa shparg ddA

Automated Control

The GUI-based software allows service provisioning, monitoring and


troubleshooting with an easy-to-use central network management
application. Pro-Vision provides rapid service creation, powerful
performance monitoring including real-time performance metrics,
port, and EVC utilization.
Pro-Vision offers a Web-based customer portal that allows
monitoring of real time service performance and SLA verification
based on the customers view. Pro-Vision supports standard based
Web services northbound interface using SOAP/XML, CORBA, and
SNMP for interconnection with SP & equipment vendor OSS systems.

(*) Future Software release

Master-OS

Service
Provider
OSS/BSS

TM

WAN

LAN

OS-906G

PS2 FAN

PS1 PWR
CONSOLE EIA-232

PS1 PWR
CONSOLE EIA-232

BITS
L

MGT ETH

S1

BITS
L

S1

S2

Metro Ethernet Network

OS-906G

PS2 FAN

MGT ETH

S2

OS-906G

PS2 FAN

PS1 PWR
CONSOLE EIA-232

PS2

CONSOLE EIA-232
USB HOST

10

11

12

13
10GE-XFP

PS1

TMP

14
10GE-XFP

OptiSwitch OS940

FAN
L
A

L
A

L
A

L
A
1

15
10GE-XFP

16
10GE-XFP

BITS
L

MGT ETH

S1

S2

Service Specifications
MEF Services

MEF-compliant CE2.0 services


UNI Type 1 and Type 2
External-NNI & Internal-NNI
EPL, E-Line, E-Tree, E-LAN, E-Access per MEF9
EPL, E-Line, E-Tree, and E-LAN Traffic Management per MEF14
OAM Implementation Agreement (IA) per MEF17
All interfaces can be configured as UNI or NNI

Packet Switching Services


IEEE802.1Q and IEEE802.1ad provider bridges
- 4K active VLANs/EVCs
- Selective Q-in-Q stacking per ACL criteria
- Private VLAN
- Inner classification on double tagged frames
- Configurable Ethertype values
Configurable jumbo frames per port/EVC- up to16 KB
Transparent cross-connect mode
- Per System, per port, or per EVC non-learning mode
Layer 2 tunneling of control protocols

Packet Ring and Link Protection Services

ERPS per ITU-T G.8032v2/Y.1344


ELPS per ITU-T G.8031
MSTP per IEEE 802.1s
Sub 50 ms network recovery for ring and dualhomed
topologies
Link Aggregation (LAG n+1) static and LACP
- Load balancing based on L2-3-4 headers
Link level 1:1 Loss of Signal (LOS) protection
Hardware-based OAM CFM messages for fault detection and
link fallback
Bi-directional Link Fault Reflection

Multicast and IP Services


Wire-speed multicast replication
IGMP v1,v2 snooping , proxy, and fast leave, PIM-SM, PIM-SSM
Wire-speed IPv4 and IPv6 packet fowarding and routing
- RIP, RIPng, OSPFv2, OSPFv3 , BGP4, BGP4+, VRRP
- BFD
- DHCP server/client/relay

Layer 2.5 Services

MPLS LER & LSR functionality


Ethernet over MPLS pseudowire with Traffic Engineering
MPLS Protection based on FRR detour mode and dual-homed
spoke MTU-s
MPLS BFD for MPLS OAM (based on RFC 5884)
MPLS OAM (MPLS PING / MPLS Traceroute)

High Availability
Pluggable 1:1 Hot-swappable dual redundant power
- AC and/or DC (for OS906G-M models)
Ambient temperature sensor for alerting
Dual image and rollback processes
Modular control plane - Master-OS

Traffic Management
Traffic management per flow/EVC/Port
Shaping and policing at L1/L2/L3
Ingress and egress policing and shaping
Color aware and color unaware BW-profile per MEF 10.2
Congestion avoidance mechanisms: Tail-Drop and Weighted
(*) Future Software release

Random Early Discard (WRED)


Scheduling Mechanisms: Strict-Priority (SP), round-rubin (RR),

and weighted round-rubin (WRR)


Classification by L1, L2, L3 and L4 criteria (Physical port, MAC,

Ethertype, double VLAN tags, IP/ TCP/UDP)


Marking or/and Remarking profiles based on: IEEE802.1p,

DSCP, and MPLS EXP


8 hardware Service Level queues for every physical and extra

port
Counters per UNI, CoS, EVC, control protocols - 4K counters

Security
Wire-speed ACLs on L2, L3, and L4 headers
- Ingress and Egress ACLs
- Multiple actions in single ACL
MAC filters and MAC limit per port/per VLAN
UNI Broadcast/Multicast/Unicast rate control
Flood limit of OAM frames
DHCP Relay Agent Information Option 82 per RFC 3046
ACL for management sessions from NOC

Management & Diagnostics Tools

Out-of-band management via EIA-232 console port


Out-of-band Ethernet management port
Industry Standard CLI
Link Layer Discovery Protocol (LLDP) per IEEE802.1ab
Hierarchical Administration policy
TELNET, SSHv2, SNMPv3, RMON (4 groups)
Port mirroring - ingress & egress traffic to analyzer port
RADIUS and TACACS+ AAA
Configuration load/save with FTP or Secure Copy (SCP)
Network Time Protocol (NTPv3)
Internal / Remote Syslog
IPv6 management
Supported by MRVs ProVision Service Provisioning and NMS

Standard-based OAM
EFM Link OAM per IEEE802.3ah
- discovery, port-loopback, and dying gasp
End-to-end Service OAM per IEEE802.1ag
- Connectivity Fault Management per service MEP/MIP
- In-service EVC loopbacks, linktrace and continuity check
End-to-end Performance Measurement ITU-T Y.1731
MEF SOAM PM (MEF 35)
End-to-end IP SLA measurement
- Jitter, Latency andLoss per service with ns accuracy
RFC2544 internal tester for wire-speed throughput
measurement
Y.1563 MEF 10.2 service availability and resilency
measurement
Y.1564 service turn-up (*)
Optical signal level monitoring (SFP SFF-8472)
Copper cable diagnostics (TDR) on RJ45 ETH ports
Integrated 3rd party OAM probes for end-to-end proactive
speech and video quality & performance measurement to
assure strict SLAs to the service providers customers

Timing & Synchronization Services


(for OS906G-M/MBH and OS906G-M/MBH/E)

ITU-T G.8261, G.8262, G.8264 , ITU -T G.703


ITU-T G.736, G742, G.813, G.823, G.824
IEEE1588v2 PTP Telecom Profile
IEEE1588v2 PTP Master */Slave/BC modes

Technical Specifications
Regulatory compliance

Temperature Range
Extended Temperature Range

OS906G
OS906G-M
FCC Part 15 (class A); EMC Directive (class A emission, immunity); Low Voltage Directive (electrical safety);
RoHS Directive; WEEE Directive; CE; TUV-R (USA, Canada); GOST (for selective products); REACH SVHC;
ETSI (for selective products); NEBS Level 3 Certified (OS906G-M/E and OS906G-M-MBH/E),
C-Tick (for selective products).
Operating Temp: 0oC to 50oC (32 to 122 oF) Storage Temp: -40oC to +70 oC (-40 to 158 oF)
NA

Humidity (max.)
Physical dimensions
WxDxH

Weight
MTBF

Max. Power Consumption


Power Feeding

Optional desktop power supply

-40oC to +65 oC (-40 to 149 oF):


applicable for OS906G-M/E and OS906G-M-MBH/E
85% (non-condensing)

219.6 x 265 x 43.65mm3


(8.64 x 10.43 x 1.72 inch3)
1.05 kg (2.31 lb)

444.0 x 230 x 43.65mm3


(17.3 x 9.05 x 1.72 inch3)
1.7 kg (3.74 lb) - without PS
2.45 kg (5.39 lb) - with PS
OS906G-AC 148410 hr @ 25 oC
597850 hr @ 25 oC (OS906G-M/E)
OS906G-DC 485496 hr @ 25 oC
525456 hr @ 25 oC (OS906G-M)
437168 hr @ 25 oC (OS906G-M-MBH/E)
23W
30W
AC Input Voltage Line (frequency 50 to 60Hz):
100 to 240 Vac
DC Input Voltage:
18 to 60 Vdc
5V, 8A, 40W

NA

All statements, technical information and recommendations related to the products herein are based upon information believed to be reliable or accurate. However, the
accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. Please contact MRV Communications for more information.
MRV Communications and the MRV Communications logo are trademarks of MRV Communications, Inc. Other trademarks are the property of their respective holders.

MRV-OS-906G
Rev.3 04

Copyright 2014 MRV Communications, Inc. All Rights Reserved.

You might also like