STM32 Firmware Upgrade Tool UGD V1.00

Download as pdf or txt
Download as pdf or txt
You are on page 1of 18

STM32_Firmware_Upgrade_Tool

User Guide
TRACUT002
Revision: 1.00

http://www.queclink.com
[email protected]

STM32_ Firmware_Upgrade_Tool User Guide

Document Title:

STM32 Firmware_Upgrade_Tool User Guide

Revision:

1.00

Date:

2013-08

Status:

Release

Document Control ID:

TRACUT002

Q
Co ue
nf cli
id nk
en
tia
l

General Notes
Queclink offers this information as a service to its customers, to support application and
engineering efforts that use the products designed by Queclink. The information provided is
based upon requirements specifically provided to Queclink by the customers. Queclink has
not undertaken any independent search for additional relevant information, including any
information that may be in the customers possession. Furthermore, system validation of this
product designed by Queclink within a larger electronic system remains the responsibility of
the customer or the customers system integrator. All specifications supplied herein are
subject to change.

Copyright
This document contains proprietary technical information which is the property of Queclink
Limited., copying of this document and giving it to others and the using or communication of
the contents thereof, are forbidden without express authority. Offenders are liable to the
payment of damages. All rights reserved in the event of grant of a patent or the registration of
a utility model or design. All specification supplied herein are subject to change without
notice at any time.
Copyright Shanghai Queclink Wireless Solutions Co., Ltd. 2013

TRACUT002

-1-

STM32_ Firmware_Upgrade_Tool User Guide

Contents
Contents ............................................................................................................................................2
Figure Index ......................................................................................................................................3
0. Revision history ............................................................................................................................4
1. Tool Introduction...........................................................................................................................5
1.1. System Requirements..........................................................................................................5
1.2. Tool Interface ......................................................................................................................5
1.2.1. Introduction of the UI ...............................................................................................5
Basic Information Setting Area.................................................................................... 6

1.2.1.2.

Tool Configuration Setting Area .................................................................................. 6

1.2.1.3.

Upgrade File Select Area ............................................................................................. 6

1.2.1.4.

Progress Show and Control Area ................................................................................. 6

Q
Co ue
nf cli
id nk
en
tia
l

1.2.1.1.

2. Upgrade Operation Instruction......................................................................................................8


2.1. Step1_Upgrade Prepare.......................................................................................................8
2.2. Step2_Upgrade Tool Basic Setting......................................................................................8
2.3. Step3_Power Off Device...................................................................................................10
2.4. Step4_Click Start Button................................................................................................... 11
2.5. Step5_Connect Device to Upgrade Cable ......................................................................... 11
2.6. Step6_Upgrade Process..................................................................................................... 11
2.7. Step7_Upgrade Accomplishment ......................................................................................13
3. FQA.............................................................................................................................................14
3.1. COM_PORT_OPEN_FAIL...............................................................................................14
3.2. UPDATE FILE NOT FOUND ..........................................................................................15
3.3. Target is not responding ....................................................................................................16
3.4. Progress Bar Does Not Run ..............................................................................................16

TRACUT002

-2-

STM32_ Firmware_Upgrade_Tool User Guide

Figure Index
FIGURE 1: UI OF THE MAIN INTERFACE .........................................................................................6
FIGURE 2: UI OF STOP UPGRADE ......................................................................................................7
FIGURE 3: UI OF PROGRESS BAR......................................................................................................7
FIGURE 4: UI OF SELECTING MODEL NAME..................................................................................9
FIGURE 5: UI OF PORT .........................................................................................................................9
FIGURE 6: UI OF BAUD RATE ...........................................................................................................10
FIGURE 7 : UI OF SELECTING FW FILE ..........................................................................................10
FIGURE 10 : UI OF TRASFERRING ...................................................................................................12

Q
Co ue
nf cli
id nk
en
tia
l

FIGURE 11: UI OF CLEAR DATA PERCENT.....................................................................................12

FIGURE 12: UI OF UPGRADE OK......................................................................................................13


FIGURE 13: UI OF PORT ERROR .......................................................................................................14

FIGURE 14: UI OF UPGRADE WITH INCORRECT FW FILE .........................................................15


FIGURE 15: UI OF TARGET IS NOT RESPONDING ........................................................................16

TRACUT002

-3-

STM32_ Firmware_Upgrade_Tool User Guide

0. Revision history
Date

Author

Description of change

1.00

2013-08

Linda lu

Initial

Q
Co ue
nf cli
id nk
en
tia
l

Revision

TRACUT002

-4-

STM32_ Firmware_Upgrade_Tool_ User Guide

1. Tool Introduction
Queclink _STM32_ Firmware__Upgrade_Tool is PC tool which can be used to upgrade
firmware which provided by Queclink.

1.1. System Requirements


The tool can run in PC without install, and the operation system must be in the list below:
Windows 95
Windows 98
Windows 2000
Windows ME
Windows XP
Windows 7
Windows 8

Q
Co ue
nf cli
id nk
en
tia
l

Any upgraded version of the tool will be informed in advance and provided by Queclink.

1.2. Tool Interface


1.2.1.

Introduction of the UI

The Figure 1 shows the main interface of the tool.

Basic Information
Setting Area

Tool Configuration
Setting Area

Upgrade File
Select Area

Progress Show
and Control Area

TRACUT001

-5-

STM32_ Firmware_Upgrade_Tool_ User Guide

Figure 1: UI of the main interface


1.2.1.1. Basic Information Setting Area
It include <Model Name> setting and <Operation> setting in basic information setting area.

Q
Co ue
nf cli
id nk
en
tia
l

<Model Name>:
It supports gv500w model names to upgrade firmware, .Please select the correct model name in
<Model Name> drop down menu.
<Operation>:
Option Upgrade Firmware and Clear User Data: It is default option. After upgrade firmware in
this option, device will be run in default parameters as factory set. Suggest using this option in
upgrading if not familiar with device.
Option Upgrade Firmware Only: Only upgrade firmware. And protocol parameters will be
saved as before, if firmware supported.

1.2.1.2. Tool Configuration Setting Area

<Port>:
Make sure select correct serial port according to cable between PC and terminal.

<Baud rate>:
It is baud rate to upgrade. It will infect the time of upgrade process. Suggest 460800 or above.
1.2.1.3. Upgrade File Select Area

<Set FW>:
FW file will be found in firmware file. Select correct Fw file which would upgrade to.
1.2.1.4. Progress Show and Control Area

<Start><Stop> button:
Start and stop upgrade process.
Warning:
Click the Stop button to stop upgrading. But if the upgrade process is interrupted, there would be
no valid firmware in the module. So it is strongly recommended never to stop the firmware
upgrade process.

TRACUT001

-6-

Q
Co ue
nf cli
id nk
en
tia
l

STM32_ Firmware_Upgrade_Tool_ User Guide

Figure 2: UI of Stop Upgrade

<Progress Bar>:
Indicate progress of upgrading process.

Figure 3: UI of Progress Bar

TRACUT001

-7-

STM32_ Firmware_Upgrade_Tool_ User Guide

2. Upgrade Operation Instruction

2.1. Step1_Upgrade Prepare


Prepare list is as below:
NO. Contact
Device

Remark

Queclink

You need know the production type of

production

device, like GV500W.

Q
Co ue
nf cli
id nk
en
tia
l

Description

Each device type has its own upgrade

Upgrade

Upgrade Cable

Cable

for

device

cable.

Note: Please make sure upgrade cable


always connect to PC.

Queclink will provide cable driver

Make

Driver of Cable

sure installer

cable can be PL2303_Prolific_DriverInstaller.exe.


identified by But
PC.

driver

also

would

be

found

automatically in WIN 7 or above system


after insert upgrade cable to PC.
Getting from Queclink.

Firmware

Firmware File

which
want

you

to

upgrade to.

Computer

PC for short

Queclink_STM32_Firmware Upgrade
_Upgrade_Tool

tool

Note:

Normally

we

will

compress

the

firmware file to you. But please make


sure decompress this file.

Please refer to Chapter 1.1 system

requirements.

Getting from Queclink.

2.2. Step2_Upgrade Tool Basic Setting

In this step, you must already insert upgrade cable to your PC. And now, open
Queclink_STM32_Firmware_Upgrade_Tool and configure basic information in tool,
including <Module Name>, <Operation>, <Port>, <Baud rate>, and <Set FW>.

TRACUT001

-8-

Q
Co ue
nf cli
id nk
en
tia
l

STM32_ Firmware_Upgrade_Tool_ User Guide

Figure 4: UI of selecting model name

Figure 5: UI of Port

TRACUT001

-9-

Q
Co ue
nf cli
id nk
en
tia
l

STM32_ Firmware_Upgrade_Tool_ User Guide

Figure 6: UI of Baud rate

Figure 7 : UI of Selecting FW File

2.3. Step3_Power Off Device

Make sure power off device, and device does not connect to upgrade cable.

TRACUT001

- 10 -

STM32_ Firmware_Upgrade_Tool_ User Guide

2.4. Step4_Click Start Button

Q
Co ue
nf cli
id nk
en
tia
l

Click Start button in Queclink_STM32_Firmware_Upgrade_Tool.

Figure 8 : UI of Starting Upgrade

2.5. Step5_Connect Device to Upgrade Cable


Connect device to upgrade cable.

Figure 9 : UI of found device

2.6. Step6_Upgrade Process


There are several steps in the progress of upgrading firmware.
TRACUT001

- 11 -

STM32_ Firmware_Upgrade_Tool_ User Guide

Q
Co ue
nf cli
id nk
en
tia
l

Trasferring(0-100%)
Clearing the user data,please wait...
Mission Accomplish.PASS.
Dialogue frames are shown in Figure 8 : UI of , Figure 9.

Figure 8 : UI of Trasferring

Figure 9: UI of Clear data Percent

TRACUT001

- 12 -

STM32_ Firmware_Upgrade_Tool_ User Guide

Q
Co ue
nf cli
id nk
en
tia
l

2.7. Step7_Upgrade Accomplishment

Figure 10: UI of Upgrade OK

TRACUT001

- 13 -

STM32_ Firmware_Upgrade_Tool_ User Guide

3. FQA

Q
Co ue
nf cli
id nk
en
tia
l

3.1. COM_PORT_OPEN_FAIL

Figure 11: UI of Port ERROR

PossibleReason

Solution

COM port is occupied by other tools, this tool cannot open


COM.

Release this COM in other


tools.

Upgrade cable is not connected.

Connect cable to PC.

This COM port is dead.

Reboot PC.

TRACUT001

- 14 -

STM32_ Firmware_Upgrade_Tool_ User Guide

Q
Co ue
nf cli
id nk
en
tia
l

3.2. UPDATE FILE NOT FOUND

Figure 12: UI of Upgrade with Incorrect FW File

PossibleReason

Solution

Wrong FW file select.

Correct the FW file.

TRACUT001

- 15 -

STM32_ Firmware_Upgrade_Tool_ User Guide

Q
Co ue
nf cli
id nk
en
tia
l

3.3. Target is not responding

Figure 13: UI of Target is not responding

PossibleReason

Solution

Target is not responding

Re-upgradey.

3.4. Progress Bar Does Not Run

Follow the standard steps, in step 2.6, progress bar does not run in this step.

TRACUT001

- 16 -

Q
Co ue
nf cli
id nk
en
tia
l

STM32_ Firmware_Upgrade_Tool_ User Guide

Figure 16: UI of Progress Bar Does Not Run

PossibleReason

Solution

Upgrade Cable Broken

Change another upgrade cable to try;

Serial port problem

1) Make sure COM Port is available or try to change


another valid COM Port;
2) Reboot PC and try to upgrade once more.

TRACUT001