GSM g20 Alarm System Manual

Download as pdf or txt
Download as pdf or txt
You are on page 1of 14

G20E & G20EA

GSM ALARM SYSTEM

Dear users,
-1-

Thank you for purchasing our products. Please read through this manual before using this product so
as to operate the product properly.
The GSM alarm system adopts the newest GSM network and Digital Signal Processing technology,
and is widely used in security field. With SMS data transmission and voice platform of GSM
network, it really realizes wireless alarm control and remote managements and solves the limitation
of wired data transmission in telephone and wired network.
Perfect structure, convenient installation, easy operation with wireless control keyboard are designed
for the idea of people-oriented, which will make you feel easy and comfortable while use this
system.
People is center, technology is first is our companys action rule. Customer Satisfaction is our
consistent pursuit. Perfect system, excellent services, sincere attitudes will bring you a new
enjoyment.

-2-

Contents
I.Instruction..............................................................................................................................1
.Installation...............................................................................3
2.1 Alarm Hosts section figure..................................................................................................3
2.2 Insert a valid SIM into the alarm host..........................................4
2.3 Run...................................................4
. Operation steps..........................................................4
3.1 Set by keyboard...................................................5
3.1.1 Password verification................................................................5
3.1.2 Set/delete three mobile phone numbers for SMS alarm............................................5
3.1.3 Set/delete three phone numbers for auto-dialing alarm.............................................5
3.1.4 Change password of the alarm host...........................................6
3.1.5 Set new ID of the alarm host.........................................6
3.1.6 Set type of 8 wireless guarding zone.............................................7
3.1.7 Set time of the alarm host..............................................7
3.1.8 Set/cancel the time of arm/disarm/partial arm...................................................................7
3.1.9 Prohibit/allow sending SMS while arm/disarm the system by controller or keyboard.......8
3.1.10 Alarm............................................................................................................................... 8
3.1.11 Exit setting status......................................................8
. SMS control command........................................................................................8
4.1 Set three mobile phone numbers for SMS alarm...................................................................9
4.2 Set three phone numbers for auto-dialing alarm-...........................................9
4.3 Delete alarm phone numbers.................................................................................................9
4.4 Change password of the alarm host...................................................9
4.5 Arm/disarm..............................................................10
4.6 Change guard zones name..........................................10
4.7 Inquire hosts arm/disarm status..............................................11
4.8 Inquire hosts external power status.....................................................11
. Usage...............................................................................11
5.1 Arm/partial arm/disarm by remote controller...............................................11
5.2 Emergency alarm.................................................11
5.3 External power failurealarm.....................................................11
-3-

5.4 Alarm and handle.....................................................11


. Operation Cautions...........................................................12
. Encode the wireless detectors and remote controller.............................................13
Appendix: Operationguideline...................................................14

-4-

1. Instruction
The alarm system adopts SMS data transmission and voice platform of GSM network to send control
command and receive alarm remotely. The system can be set delayed-arm. When a signal is detected
by detectors, the detectors will send alarm signal to host immediately, then the host sends alarm SMS
to its preset mobile phone numbers, and meanwhile dials its preset telephone/mobile phone numbers
automatically and drive wiretap. In addition, the color LCD can show the time, date and the status of
arm, disarm, GSM signal, power, alarm etc. With the LCD, it is very easy for you to operate.
Following are the specific functions,
1. With Wavecome double frequency GSM module.
2. With color LCD show screen and keyboard on the host.
3. 10 wireless guarding zones (1 wireless SOS zone, 1 fire alarm zone, and other 8 wireless guarding
zones can be defined by user ) and 1 external power failure alarm zone.
4. Send SMS to 3 preset mobile phone numbers automatically while alarming.
5. Call 3 preset phone numbers automatically and monitor at site while alarming.
6. Set the time of arm/partial arm/disarm.
7. Arm/disarm by the keyboard on the host, remote controller or SMS.
8. Program the alarm host by keyboard or SMS.
9. Modify the name of 8 wireless guarding zones and inquire the status of alarm host by SMS
demand.
10. Define the 8 wireless guarding zones as arm/partial arm by keyboard on the alarm host.
11. With standby rechargeable battery
12. The alarm host automatically stores system status, while its power is off.
13. Connect with the alarm center through GSM network.

Specification
a) GSM
GSM frequency: 900/1800MHz or 850/1900MHz
Consumption: 1W (while sending message)
b) Working frequency of detectors
-5-

315M & 433M (optional)


c) External power failure alarm
Start-time: less than 2s
d) Alarm response time
Less than 8s (GSM in normality)
e) The volume of siren
More than 110db
f) Power
Power requirements: AC 110-220V 50Hz or 60Hz
Working power consumptionless than 3W
Standby batteryDC 8.4V
Standby battery working hours: more than 15 Hours
g) Working conditions
Operating temperature: -20 ~ 60
Humidity: 20% to 95%
h) Weight of alarm host
Net weight: 0.5Kg
Gross weight: 0.75Kg
i) Dimension of alarm host
Dimension: 160mm (Long)113mm(Wide)38mm(High)

. Installation
2.1 Alarm Hosts section figure

-6-

2.2 Insert a valid SIM into the alarm host


Before installing the host, remove the SIM slot cover with screwdriver and insert SIM card.

2.3 Run
Make sure that the power supply is connected correctly, and turn on the host power switch. The alarm
host will search the GSM network automatically within 25 seconds after it is started. Then the LCD
display turns on and shows the time and the status of arm, disarm, GSM signal etc. The COM is
twinkling. When the external power is normal, the LCD display keeps on. If there is no external power,
it is off automatically after operation.
. Operation steps
Note: When setting by the keyboard, every time you press the button you will hear di sound
for confirmation. If theres no voice, you can press it again. To cancel the input numbers, please
press CLS button before inputting OK. If the LCD display shows FAIL, please check and
reset it.
3.1 Set by keyboard
3.1.1 Password verification
Press SET, input password + OK, then you will hear di,di sound for confirmation. While SET
and SMS appear on LCD display, it means that the password is correct.
Note: The initial password is 1234 (must be four numbers).
3.1.2 Set/delete three mobile phone numbers for SMS alarm.
a) Set the mobile phone number
After passing the verification of password, press SET button, when SET, SMS appears on the
LCD display, input serial number + mobile phone number + OK

-7-

Example: Set 1368888888 as the first mobile phone number for SMS alarm. Input: 1+ 1368888888 +
OK, then you will hear di, di sound for confirmation.
According to the method, you can finish the setting of the other two mobile phone numbers.
Note: Serial number can only be 1, 2, 3 and the number 1 is the first mobile phone number. for SMS
alarm. The phone No. must be less than/in 20 numbers.
b) Delete the mobile phone number
Input: serial numberOK, then you can cancel the mobile phone numbers.
3.1.3 Set/delete three phone numbers for auto-dialing alarm
a) After passing the verification of password, press SET button, when SET, TEL appears on the
LCD display.
Input: serial numberphone number + OK
Example: Set 1368888888 as the first phone number for auto-dialing alarm. Input: 4 + 1368888888 +
OK, then you will hear di, di sound for confirmation.
Note: Serial number can only be 4, 5, 6 and the number 4 is the first phone number for auto-dialing
alarm. The phone number can be mobile phone or telephone, but mustnt be more than 20 numbers.
b) Delete the phone number
Input: serial numberOK, then you can cancel it.
3.1.4 Change password of the alarm host
After passing the verification of password, press SET, when SET, PAS appears on the LCD display,
Input: 7new password + OK,
Example: Set 4321 as the new password.
Input: 7 + 4321 + OK, then you will hear di, di sound for confirmation.
Note: The initial password is 1234 (must be four numbers).
3.1.5 Set new ID of the alarm host
After passing the verification of password, press SET, when SET,ID appears on the LCD display.
Input: 0 + six new ID numbers + OK,
Note: the initial ID is 000000.
Example: Set 123456 as the new ID.
Input: 0 + 123456 + OK, then you will hear di, di sound for confirmation.
3.1.6 Set type of 8 wireless guarding zones
After passing the verification of password, press SET, when SET, TYPE
appears on the LCD display,
Input: + zone numbers (When there is illegal intrusion, the zones will alarm in partial arm mode) +
OK
Example: Set zone 4, 6, 8 as alarm zones in partial arm mode, input + 4 6 8 + OK, then you will
hear di, di sound for confirmation. When alarming, zone 4, 6, 8 will alarm but other five zones will
not alarm in partial arm mode.
3.1.7 Set time of the alarm host
After passing the verification of password,
press SET, when SET, appears on the

-8-

LCD display,
Input: 8 + year/month/day/hour/minute/second (each with two numbers) + OK, then you will hear di,
di sound for confirmation.
Example: Suppose the present time is 12:13.05 and the date is 08-01-2007, input 8 +
070108121305+OK.
3.1.8 Set/cancel the time of arm/disarm/partial arm
a) Timing arm
In arming status, press SET, when SET,
appears on the LCD display, then Input: * +
time (hour/ minute) + OK.
Example: Set 16:08 as the arm time, input *
+ 1608 + OK, then you will hear di, di sound for confirmation.
To cancel it, press * + 9999 + OK in arm mode.
b) Timing partial arm
In partial arm status, press SET, when
SET, appears on the LCD display, then
input: * + time (hour/minute) + OK.
Example: Set 16:25 as the partial arm time,
input * + 1625 + OK, then you will hear di, di sound for confirmation.
To cancel it, press * + 9999 + OK in partial arm mode.
c) Timing disarm
In disarming status, press SET, when SET,
appears on the LCD display, then input: *
+ time (hour/minute) + OK.
Example: Set 16:35 as the disarm time,
input * + 1635 + OK, then you will hear di, di sound for conformation.
To cancel it, press * + 9999 + OK in disarm mode.
3.1.9 Prohibit/allow sending SMS when arm/disarm the system by controller or keyboard
After passing the verification of password, press SET, when SET appears on LCD display, input 9 +
OK, then you will hear di, di sound for confirmation.
3.1.10 Alarm
When the host alarms, ,
SMS,
TEL
and
guarding zones will appear
on the LCD display and it
will drive siren to sound
for
90
seconds.
(P:
external power failure, E:
SOS alarm, F: fire alarm,
1-8
wireless
guarding
zone).
3.1.11 Exit setting status
In the setting status, the
host
will
exit
-9-

automatically if there is no response within 15 seconds.


After setting successfully, press ESC to exit.
. SMS control command
4.1 Set three mobile phone numbers for SMS alarm.
Input SMS: 4 numbers for password + DD + serial number + mobile phone number.
Example: Set 1388888888 as the first mobile phone number for SMS alarm. The hosts password is
1234.
Send SMS: 1234DD11388888888
Note: The serial number shows alarm sequence (must be 1,2, 3).
4.2 Set three phone numbers for auto-dialing alarm
Input SMS: 4 numbers for password + DD + serial number + phone number.
Example: Set 01088888888 as the first phone number for auto-dialing alarm. The hosts password is
1234.
Send SMS: 1234DD401088888888
Note: The serial number shows alarm sequence (must be 4, 5, 6).
4.3 Delete alarm phone numbers
Input SMS: 4 numbers for password +DD + serial number.
Example: The hosts password is 1234. If you want to delete the first alarm phone number,
Send SMS: 1234DD1
Note: The serial number shows alarm sequence (must be 1, 2, 3, 4, 5, 6).
4.4 Change password of alarm host
Input SMS: 4 numbers for password + DD +7 + 4 new numbers for password
Example: The initial password is 1234, if you want to set 5678 as the new password,
Send SMS: 1234DD75678.
4.5 Arm/disarm
SMS for remote arm: 4 numbers for password +A1
SMS for remote disarm: 4 numbers for password +A2
Example: The hosts password is 1234. If you want to set the host in arm mode.
Send SMS: 1234A1
4.6 Change zones name
Input SMS: 4 numbers for password + DM + zones code (2 numbers) + changed name
Reply SMS: Changed zones name
Example: The password is 1234. If you want to change zone 06s name to be PIR alarm for
bedroom.
Send SMS: 1234DM06 PIR alarm for bedroom
Note: Changed name should be less than 24 characters.
Zones code: 01 to 08, each code with two numbers.

- 10 -

4.7 Inquire hosts arm/disarm status


Input SMS: 4 numbers for password + W1
Reply SMS: The hosts arm/disarm status
4.8 Inquire hosts external power status
Input SMS: 4 numbers for password + W2
Reply SMS: The hosts external power status

. Usage
5.1 Arm/disarm by remote controller
a) Arm: Press on remote controller,
the host will make di sound,
the LCD display is on, is twinkling.
30 seconds later, the host enters
into arm mode and the is on. If you
want to arm the system quickly,
please press .
b) Partial arm: press ,
the host will make di
sound, the LCD display is
on. is twinkling. 30
seconds later, the host
enters into partial arm
mode and is on. Press
the , the host will enter
into partial arm mode
immediately.
c) Disarm: Press to
close the system, the host
enters into disarm status
after the host makes di, di
sound and the is on.
5.2 Emergency alarm
When
an
emergency
alarm occurs, press and
the host will enter into
emergency alarm status
immediately and the siren
will alarm for 90 seconds
to inform the neighbors.
At the same time, it will
automatically dial
the
preset
alarm
phone
- 11 -

numbers cycled for three times and send SMS of Emergency alarm
5.3 External power failure alarm
When the system checks out that there is something wrong with the external power or the external
power is off for more than 2 seconds, it will enter into alarm status immediately. At the same time, the
system will automatically dial the preset phone numbers cycled for three times and send the SMS of
External power failed.
When the power supply is on, the system will stop alarming immediately and send the SMS of
External power is OK.
5.4 Alarm and Handle
When an alarm occurs, the siren will alarm for 90 seconds to inform the
neighbors. At the same time, the system will automatically send SMS to report the guarding zones and
dial the preset phone numbers. When any phone is answered, you can monitor the alarm site. If the
phone line is busy or cant put through, the system will auto-dial the next phone number circularly till
one of them is answered. If nobody answers the phone, the system will stop dialing after auto-dialing
circularly for three times.

. Operation Cautions
1. Make sure the equipments have no water.
2. Install the system in a hidden place.
3. Turn off the power supply before insert/take out the SIM card.
4. Connect the power supply firmly and provide good heat dissipation.
5. Dont install the system close to the objects which generate strong interference, such as TV
set and computer.
6. Check all the detectors and their battery in time and change them when voltage is low.
7. Inspect the GSM alarm system termly.
8. This product is designed for the indoor use rather than outdoor use.

- 12 -

. Encode the wireless detectors and Remote controller


Name

Wireless address code of product


(A0 to A7)
Note: You can see the code (A0A7) from PCB in the products

D0
13

D1
12

D2
11

D3
10

Alarm Host

There is a label with wireless


address code on the back of alarm
host. It is corresponded to A0-A7
from right to left.
A0~A7: The same as the wireless
address code of alarm host.

NC

NC

NC

NC

NC

NC

NC

NC

1
1

1
0

1
0

0
1

Zone03

Zone04

Zone 05

Zone 06

Zone 07

Zone 08

0
0

1
1

1
1

0
0

Remote Controller
PIR
Sensor,
Magnetic
Door
contact,
Beam
detector,
etc.

Zone 01
Zone02

Smoke detector
Gas detector
Emergency button
Remark: 1.Request High level N connect with H
0..Request Low level N connect with L
2..No connect
NC...No request

Appendix
Operation Guideline
By following steps, you can operate it easily though it is the first time to use this product.
1. Remove the SIM slot cover with screwdriver and insert a valid SIM card into the alarm host.
(Please see 2.2).
2. Make sure the power supply is connected; turn on the host power switch. (Please see 2.3).
3. Set the mobile phone/telephone numbers for SMS alarm and auto-dialing alarm. (For details,
please see 3.1.2, 3.1.3, 4.1, 4.2).
4. Set time of the alarm host (for details, please see 3.1.7 ).
5. As per the operation instruction of page 13, encode the wireless detectors and remote controller to
match with the alarm host, and allocate the detectors to wireless zones separately. Please make sure
to record the corresponding zone number of each detector.
6. Set zone type (please see 3.1.6 for details.).
8. Change zones name according to your needing (Please see 4.6 for more details).
9. Change password of the alarm host. (Please see 3.1.4 and 4.4 for more details.).
10. Set time of arm/disarm according to your needing. (Please see 3.1.8 for more details)
For specific operation, please read this manual carefully.

- 13 -

- 14 -

You might also like