QCP 13.0
QCP 13.0
QCP 13.0
Page 1 of 6
PURPOSE
To define the method for the identification, collection, indexing, filing, access, storage, maintenance
and disposition of quality records.
2.0
SCOPE
Records used to demonstrate conformance to specified requirements and the effective operation of
the quality system. This includes both records generated by Eaton and suppliers as applicable.
3.0
APPLICABLE DOCUMENTS
Eaton Record Retention Policy Manual
QP-5
4.0
GENERAL
4.1
Specific requirements for the generation of quality records are defined in the applicable procedures
(e.g. Quality Control Procedure (QCP) and Standard Operating Practice (SOP) etc.).
4.2
4.3
Records shall be maintained in a manner that they are readily retrievable and contained in a suitable
environment to prevent damage or deterioration.
4.4
Where contractually required, records are made available for evaluation by the customer or the
customer's representative for the required period.
4.5
When SAFRAN related documents have reached the end of their required period, Eaton shall request
approval of SAFRAN before the destruction of documents occurs. Record destruction can be halted
upon written request by SAFRAN.
4.6
If customer related documents are destroyed by an unplanned incident, Eaton shall inform the
customer immediately by any means and then in a timely manner in writing so that necessary steps
can be taken by the customer without delay.
5.0
5.1
Users may maintain current records in their area to ensure they are readily retrievable. This retention
of records is considered short term and is generally the current year's and the previous year's
records.
Date of Issue
3/6/87
Prepared By
Revisions
-AN 04/15/16
Approved
signature on file
P. Lozovyy
signature on file
G. Lallathin
QCP 13.0
Page 2 of 6
generating and maintaining records prior to being sent to long term retention.
responsible for retaining records in a manner to ensure they are readily retrievable and are
protected from damage and deterioration.
ensuring that records in short term retention are protected from loss or improper removal by
limiting access to the records to personnel with a legitimate need, as determined by the user
area.
5.2
Repair Station MRO Customer Build Records are electronically scanned upon completion and are
stored in a dedicated backed-up hard-drive. The Build Records (hard copy) are only maintained in
secured short term storage for approximately two months and then forwarded to Long Term
Retention.
6.0
6.1
The procedure for entering records into long term retention and the control of long term record
retention are described in the Eaton Record Retention Policy Manual.
6.2
Retention times for specific records are defined in Table 1, unless otherwise specified quality records
shall be retained for 10 years. In no case shall the retention time be less than seven years after final
payment on the associated contract. In no case shall the retention time be less than the life of the
engine type certificate plus two years.
6.3
Repair Station Long-term Customer Build Records (records greater than two years old) will be kept
in the secured long-term storage area.
MINIMUM
RETENTION
PERIOD
INDEXING METHOD
Initiating Cell
Discarded when
incorporated in
drawing
Supplier Quality
Permanent
Alphabetical by Supplier
TYPE OF RECORD
QCP 13.0
Page 3 of 6
TABLE 1
SHORT TERM
RETENTION
AREA/FUNCTION
MINIMUM
RETENTION
PERIOD
INDEXING METHOD
Permanent
Model/Pump Serial
Number
Current
Gage/Instrument
Number
Quality File
15 yrs.
Part Number
Casting FAI
Quality File
Permanent
Part Number
15 yrs.
Part Number
Characteristic Inspection
Reports (CIR)
15 yrs.
Part Number
Contract Reviews
Program Coordinator
Active + 15 Yrs.
Customer Purchase
Order
Corrective/ Preventive
Action
15 Yrs.
Customer Concessions
Quality Planning
Permanent
Customer/Chronological
Customer Supplied
Material
Customer Service
15 Yrs.
Quality Files
10 Yrs.
Chronological
Instrument Calibration
15 Yrs.
Chronological
Design Reviews
Permanent
Model Number
Engineering Design
Records
Engineering Department
Permanent
Program
Engineering Orders
(E.O.s)
Engineering
Permanent
Part Number/Revision
Level
10 Yrs.
Chronological
Quality Department
Permanent
Part Number
Furnace Logs/Charts
Gear/Shaft Cell
15 Yrs.
Chronological
TYPE OF RECORD
QCP 13.0
Page 4 of 6
TABLE 1
MINIMUM
RETENTION
PERIOD
INDEXING METHOD
TYPE OF RECORD
SHORT TERM
RETENTION
AREA/FUNCTION
Gage Calibration
GMS System
15 Yrs.
Gage Number
Receiving Inspection
15 Yrs.
Government Supplied
Material
Lists-Property
Administrator Unsuitable
Property Correspondence
Lists 15 Yrs.
Lists-Program/Contract
No.
Audits 15 Yrs.
Audits-Service Call
Heat Treat Equipment
Qualification
Manufacturing Eng.
Life of Equipment
Equipment Number
Human Resources
Active Employment
or 15 Yrs.
Employee Name
Inspection Status/
Manufacturing Records
WDS Mainframe
15 Yrs.
Manufacturing Quality
15 Yrs.
Function/ Stamp
Number/ Employee
Internal Audits
Quality Office
15 Yrs.
Quality Office
Instrument Calibration
Instrument Calibration
15 Yrs.
Instrument Number
Machining Equipment
Approvals
SPC Engineers
Life of Equipment
Equipment Identification
Management Reviews
Quality Files
Manufacturing Drawing
Approvals
Manufacturing
Engineering
15 Yrs.
Chronological
6 Months
Part Number/Revision
Level
Print Room
Manufacturing Traveler
Discard
At Completion
N/A
15 Yrs
By Ship Date /
Serial No.
NDT Equipment
Calibration
Instrument Calibration
15 Yrs.
Instrument Identification
Number
15 Yrs.
Month/Part Number
QCP 13.0
Page 5 of 6
TYPE OF RECORD
SHORT TERM
RETENTION
AREA/FUNCTION
MINIMUM
RETENTION
PERIOD
NDT Material
Qualification
15 Yrs.
Chronological
NDT Personnel
Qualification
15 Yrs.
Employee Name
15 Yrs.
Chronological
Nonconformance Reports
(NCR)
Manufacturing Quality
15 Yrs.
Ship Bench
15 Yrs.
Posted on Ovens
15 Yr.
Chronological
Personnel Qualification /
Training
Human Resources
Active Employment
or 15 Yrs.
Employee Name
Personnel Training
Human Resources
15 Yrs.
Employee Name
Plating Logs/Records
Plating Department
15 Yrs.
Chronological
Plating Materials
Qualification
Materials Laboratories
15 Yrs.
Chronological/ S.C.
Number
Manufacturing Eng.
Life of Equipment
Equipment Number
Plating Personnel
Qualification
Human Resources
Active Employment
or 15 Yrs.
Employee Name
Quality Files
15 Yrs.
Chronological
Product Investigation
Reports
15 Yrs.
P.I.R. Number
Product Servicing
Customer Service
15 Yrs.
Purchase Orders
Purchasing Dept.
Active + 15 Yrs.
Part Number
Quality Files
15 Yrs.
Chronological
Quality Plans
Quality Files
15 Yrs.
Model Number
15 Yrs.
Part Number
Risk Releases
Receiving Inspection
15 Yrs.
INDEXING METHOD
QCP 13.0
Page 6 of 6
TYPE OF RECORD
SHORT TERM
RETENTION
AREA/FUNCTION
MINIMUM
RETENTION
PERIOD
INDEXING METHOD
RR Airworthiness
Certificates
Permanent
Chronological
Servicing
Inglewood MRO
2 Yrs.
Part Number/Serial
Number/Work Order
10 Yrs.
Chronological
Software Retention
User Area
Indefinite
Part Number/
Revision Level
Solder Equipment
Calibration
Instrument Calibration
15 Yrs.
Instrument Identification
Number
Solder Personnel
Qualification
15 Yrs.
Employee Name
Source Change/Work
Transfers
Quality Files
15 years
Part Number
Supplier Audits
Supplier Quality
Permanent
Alphabetical by Supplier
Supplier Engineering
Design Records
Supplier Facility
Supplier Quality
15 Yrs.
15 Yrs.
40 Yrs.
Part Number
Visual Acuity
Human Resources
15 Years
Employee Name
X Ray Film
Materials Lab
15 Years
Part Number
Note: For electronic records transferred from computer file, the storage media shall be capable of
maintaining data integrity for the full retention period.