BBU3900
BBU3900
BBU3900
Issue
V1.5
Date
2012-09-19
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute the warranty of any kind, express or implied.
Website:
http://www.huawei.com
Email:
BBU3900 Description
Contents
Contents
1 Introduction.................................................................................................................................... 1
1.1 Functions of the BBU3900 ............................................................................................................................... 1
1.2 Appearance of the BBU3900............................................................................................................................ 1
1.3 Boards of the BBU3900 ................................................................................................................................... 2
ii
BBU3900 Description
1 Introduction
Introduction
Managing the entire base station in a centralized manner, including OM, signaling
processing and system clock
Providing physical interfaces connecting the base station to the transport network for
information exchange
Processing UL and DL baseband signals and providing CPRI ports for communication
with RF modules
BBU3900 Description
1 Introduction
FAN module
Function
GTMU
Provides four E1s, one FE electrical port, and one FE optical port
Provides four E1s that support both ATM transport and IP transport
Provides one FE electrical port and one FE optical port. Both of them
support the IP transport.
WMPT
BBU3900 Description
1 Introduction
Board
Function
LMPT
WBBPd: providing six CPRI ports for the communication with RF modules
The WBBPd supports the Interference Cancellation (IC) of uplink data and
must be installed in slot 2 or 3. When an RRU carries a cell with the IC
feature enabled, this RRU must be connected to a CPRI port on the
WBBPd
UTRP2: providing two FE/GE optical ports for Ethernet MAC layer
functions including sending and receiving Ethernet link data and MAC
address resolution
UTRP9: providing four FE/GE electrical ports for the MAC layer and
physical layer functions of the Ethernet
Converts the -48 V DC or +24 V DC power input to the +12 V power input
Provides two ports with each transmitting one route of RS485 signals and
another two ports with each transmitting four routes of Boolean signals.
WBBP
LBBP
UTRP
UPEU
UEIU
Provides two ports with each transmitting one route of RS485 signals and
another two ports with each transmitting four routes of Boolean signals
Transmits the information reported by the environment monitoring unit and
alarm information to the main control board
USCU
UBRI
Provides the input port for the external RGPS (such as reused devices),
BITS device, and TOD
BBU3900 Description
1 Introduction
BBU3900 Description
1 Introduction
NOTE
In GU mode, GSM and UMTS share one BBU. The same applies to GL and UL modes.
BBU3900 Description
1 Introduction
Figure 1-8 Typical board configuration of the BBU3900 in GU+L triple mode
Figure 1-9 Typical board configuration of the BBU3900 in GL+U triple mode
NOTE
In GU+L mode, GSM and UMTS share one BBU, and LTE occupies another BBU. The same
applies to GL+U mode.
BBU3900 Description
2 Technical Specifications
Technical Specifications
Capacity
GSM
S24/24/24
UMTS
GSM+UMTS
LTE
Transmission Ports
GSM
GTMU
UMTS
WMPT
UTRP2
UTRP3
8 E1s/T1s
UTRP4
8 E1s/T1s
UTRP6
1 STM-1/OC-3 port
UTRP9
BBU3900 Description
2 Technical Specifications
Mode
Transmission Ports
LTE
LMPT
Specification
Input power
UPEUc: -48 V DC
Voltage range: -38.4 V DC to -57 V DC
Specification
Dimension (H x W x D )
86 mm x 442 mm x 310 mm
Weight
Specification
Operating temperature
Relative humidity
5% RH to 95% RH
Protection rating
IP20
BBU3900 Description
Abbreviation
Full Name
ATM
BBU
Baseband Unit
BITS
CE
Channel Elements
CPRI
DL
Downlink
EDGE
FE
Fast Ethernet
GE
Gigabit Ethernet
GBBP
GLONASS
GPS
GSM
GTMU
HDLC
HSDPA
IC
Interference Cancellation
IP
Internet Protocol
LBBP
LMPT
LMT
LTE
BBU3900 Description
Abbreviation
Full Name
MAC
MIMO
OC-3
OM
OMC
RGPS
SMT
STM-1
TOD
Time of Day
UBRI
UEIU
UL
Uplink
UMTS
UMPT
UPEU
USCU
UTRP
WBBP
WMPT
10