Simple Inductance Meter PDF

This document describes the design and construction of a simple inductance meter that can measure inductance values from 10uH to 2H. The meter uses a 74HCT14 Schmitt trigger IC as an oscillator whose pulse width is proportional to the measured inductance. It has 4 switchable ranges calibrated to different maximum inductance values. Improvements over similar designs include the addition of a recovery diode and capacitor to improve accuracy, and using the HCT series IC for its lower switching thresholds and duty cycle. Calibration involves adjusting trimpots to match meter readings to known inductance values. Pictures show the circuit design and implementation on a PCB and in an enclosure.

Uploaded by

Anden pundy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
405 views13 pages

Simple Inductance Meter PDF

This document describes the design and construction of a simple inductance meter that can measure inductance values from 10uH to 2H. The meter uses a 74HCT14 Schmitt trigger IC as an oscillator whose pulse width is proportional to the measured inductance. It has 4 switchable ranges calibrated to different maximum inductance values. Improvements over similar designs include the addition of a recovery diode and capacitor to improve accuracy, and using the HCT series IC for its lower switching thresholds and duty cycle. Calibration involves adjusting trimpots to match meter readings to known inductance values. Pictures show the circuit design and implementation on a PCB and in an enclosure.

Uploaded by

Anden pundy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 13

Simple inductance meter

Introduction:Thismetercanmeasuretheinductanceofthecoilsinawiderangeof10uH2H.Itactsasacomplementtoadigitalvoltmeterora
multimeter.DigitalMultimeterisnowpossibletogetbelowCZK100,butistheinductancemetermultimetersarerare.
Description:Thebasisofthissimplemeterisasixfold74HCT14SchmitttriggerIC.Inductanceofthecoilisderivedfromthetimeperiodfor
whichtheoscillatorkeepthevoltageonthecoilabovethespecifiedlimit(thelowerthresholdofSchmitt).Rangechangeisdonesimplybychanging
thefrequencyofoscillator.IO2aconsistsofanoscillatorwithaswitchablefrequencies.SwitchtobothC5adandP1ad.P1atoP1dtrimmersareused
tocalibratetheranges.IO2bservesasaninverter,andIO2candIO2dasacurrentamplifier.Thesethreeinvertersseparatetheoscillatorfrom
measuringcircuit.Thedutycycleofoscillatorisabout25%.WhentheoutputofIO2c+dgoeslog.1,thecoilinducesthefullvoltage5V.Thisvoltage
thendecreasesexponentiallyandapproacheszero.IO2einvertersensesthevoltage.Outputisinverted,sothecircuitIO2fhasthecorrectthepolarity.
TheoutputofIO2fstayslog.1fromthemomentwhentheoscillatorfliptothelog.1,tillthevoltageacrossthecoildropsbelowthelowerSchmitt's
threshold.PulsewidthatIO2foutputisproportionaltothemeasuredinductancecoil.OutputfilterR4,C6,R6,C7convertsthePWMtotheDC
voltage.Itisthenmeasuredbyadigitalvoltmeter(multimeter)setto200mVrange.Supplyvoltageisstabilizedby7805ir78L05to5V,becauseithas
amajorimpactonaccuracy.CapacitorC4istobeplacedascloseaspossibletoIO2.Inductancemeter'sconsumptionisonlyabout48mAandcanbe
easilypoweredfrom9Vbattery.
Improvements:Thecircuitisinspiredbythe74HC132meters,whichoccursinalmostidenticalforminabouttendifferentsites:)...seeliterature.
Thismindlesslycopiedcircuit,however,sufferfrompooraccuracyandotherproblems.SoIdecidedtomakeanimprovement.IhaveincludedtheRD
cell(D1andR3),whichallowsrecoveryoftheinductance.Withoutit,theinductanceisblockedbytheprotectivediodeontheinputoftheSchmitt
(anodeontheground,thecathodetotheinput),anddoesnotallowtheinductortorecoverbetweeneachcycle.Residualcurrentremainsinthecircuit
onthenextcycleandthemeasurementisgreatlyaffected.ItturnedoutthatitisbettertousethecircuitofaseriesofHCTthanHC.Itsthresholdsare
locatedlower.Oscillatordutycyclechangesfrom50%to25%,whichismoreappropriate(Coilisnotconnectertocurrenttoolongandhasmoretime
torecover).Thelowerthresholdisalsosuitableformeasuringsmallinductances.Lowerthresholdandlowerdutycyclealsoeliminatestheproblemof
originalcircuit:Iftoohighinductancewasconnected,paradoxically,themetershowedzeroinsteadof"1___".Thiswascausedbythatlarge
inductanceinthe50%dutycyclecreatesanearlyrectangularwaveformwithpeakat2.5V,whichisnotenoughtofliptheHCseriesinputs.Withthe
HCTcircuits,thisproblemdoesnotoccur.Thecoilsisconnectedtotwoinvertersinparallel,whichwillincreasethecurrentabilities,reduceinternal
lossesandtherebycontributetotheaccuracy.HCTcircuitsandlowerdutycyclealsoensureslesspowerconsumption.Thediagramsintheliterature
mostlymissingblockingcapacitorsbeforeandafter7805(!!!).HereitisC1toC4.Ifoundthatusingthe200mVrangeprovidesmuchbetteraccuracy
than2Vrange,becausethemeasurementrangeof2Vrequiresworkingwithlongpulses(upto40%)andtheRLcircuit(R2andLX)couldnotmanage
tostabilizebeforethenextcycle.IncombinationwiththelackofD1andR3,thismaymeananerrorofuptotensof%.ThedividerR4,R5circuit
operateswithdutycycleoutputpulsesupto20%.Ifindthatthezerotrimmer(seeliterature)doesnotmakesense,becausetheoutputvoltageof

schmittsinthelog.0isnegligible.Initialinvolvementwasonly12ranges.Iused4ranges,tomeasurethelargerinductance.Higherrangesuselower
frequencieshencethetwostagefilterisused.

Callibration:Eachrangeisnecessarytocalibrateaccordingtoknowninductance.Thisshouldpreferablybeavalueof5090%ofthescale,or
displayofthe"1000""1800".CalibrationofeachscaleismadebysettingtheP1aP1dtrimmersothatthemetershowedthecorrectvalue.Ifyou
failtocalibratethemeter,changethevalueofR1,thevalueoftheP1adorC5ad.Individualrangesarelistedinthetablebelow.Ifyoudonotmeasure
theinductanceofsuchalargerange,somerangesmaybeomitted.

References:

pandatron.cz/?99&meric_civek

freecircuitdiagram.com/2009/05/12/inductancemetercircuit

xtronic.org/circuit/digitalinductimeterformultimeter

electro2.webs.com/Inductance%20Meter.GIF
elektroarea.blogspot.com/2010/03/rangkaianpengukurinduktansi.html

qsl.net/va3iul/Homebrew_RF_Circuit_Design_Ideas/Inductance_meter_using_DVM.gif

cqham.ru/projects/inductance_meter.jpg

geocities.ws/k7hkl_arv/K7HKL_Inductance_Meter.png

Pic.1Theschematicofthesimpleinductancemeter.

Pic.2Modificationforasingleswitch.Youdon'thavetousedoubleswitchinthisversion.

Pic.3Simplifiedcallibration.Youcallibreonlyonerangeandthecallibrationtheofothedrangesisderivedfromit.Thedisadvantageofthisversion
islowaccuracy.Theinternalcapacities,capacitordeviations,etc.affectthemeasurement.

Thewaveformsinthecircuit
Range
I.
II.
III.
IV.

Max.value Conversion Operatingfrequency


2mH
10uH/mV 30kHz
20mH
100uH/mV 3kHz
200mH
1mH/mV
300Hz
2H
10mH/mV 30Hz
Therangesandcalculationformulas

Developmentoftheinductancemeterinthebreadboard.


Theoscillatorwaveformonscopewith74HC14(left)andwith74HCT14(right)

BoardunderIO2(74HCT14).

thePCBboardoftheinductancemeter

RangeswitchPr1(C1addirectlyonit).

CompletedgutsoftheLmeter

Simpleinductancemeterbuildintoabox.

Inductancemeasurement.Toconnectthemultimeterissuitablefemaleconnector,whichwasusedforconnectionofthemainstotheboardofATX
powersupply.

Testovn mie induknost - Inductance meter test

Testingtherangesoftheinductancemeterusingthespeaker.Youcanhearthefrequency300Hzand3kHz,30Hzisheardfaintlyand30kHznotatall.