Thermal Insulation
30% of overall ducting
Accoustic Insulation
15% of overall ducting
Supply Grill/Supplu Diffuser/collar damper
(Total cfm/450)Sq.Ft
Fresh Air Damper
(CFM/500)Sq.Ft
Return Grill/diffuser ((Sq ft) lesser velocity
equal to 1.5 times supply grill/diffuser
1 Ton=80Sq Ft of Ducting
Duct Static Pressure-0.1inch per 100ft
1000 cfm to 3000 cfm fan
Max 23-24 Rs/cfm
3000cfm to 10000cfm fan
Max 15-16 Rs/cfm
10,000 to 24,000 and above
Max 13 Rs/cfm
large AHU
50-65mm Static Pressure
Small AHU
40 mm Static Pressure
Pressure Dtop Across Wet Scrubber
18mm
chennai
150Sqft/TR
Bangalore
180 Sqft/TR
Mysore
200Sqft/TR
Power Consumption(Water Cooled)
0.9KW/ TON
Power Consumption(Air Cooled)
1.35 KW/TON
Cooling tower water circulation rate/TR
0.8m3/hr
1 MW of power generation (heat recovery)
300 ton of chilling is possible
40% efficiency for GENSET without waste heat recovery,with waste heat recovery total cyc
VAM-low efficiency m/c
1 TR = 3024 kcal/hr of heat removal is possible.
Normal 7.2 cfm per person / 1 air change
Cafetaria 10 cfm / person
Hi wall split units - 1 TR - max - Rs 26,000 (including copper piping +electrical + insulation
VRF - 1 TON Rs 60,000 per ton (low side & high side )
Thumb rule
value(RS)
21,000
15,000
6,500
10,000
4,000
26
9,000
38,000
30,000
all ducting
all ducting
50)Sq.Ft
q.Ft
times supply grill/diffuser (Sq ft)
tatic Pressure
ic Pressure
0.6 KW/ton for chiller + 0.3 KW /ton for lowside(like pumps,AHU,cooling tower)
1.2 kw/ton for chiller + 0.15 kw/ton for Pumps,AHU's
hilling is possible
ste heat recovery total cycle efficiency of 75 % is possible.
REMARKS
YORK MAKE
YORK MAKE
Includes primary,secondary pumps and its all interconnecting pipes and valves.
Includes primary,secondary,condensor pumps,cooling towers and its all interconnecting pipes and val
Includes chilled water piping distribution form secondary pump discharge to primary pump suction an
includes ducting,insulation,damper,grills etc
CFM
0-2500
2500-5000
5000-10000
1000-15000
15000-20000
>20000
Erection labour
CFM
0-2500
2500-5000
5000-10000
1000-15000
15000-20000
>20000
Remark
From Murali
From Murali
From Murali
From Murali
From Murali
From Murali
on
on
on
on
on
on
21/03/12
21/03/13
21/03/14
21/03/15
21/03/16
21/03/17
S.No.
Brand
YORK
BLUE STAR
VOLTAS
CARRIER
5
6
TRANE/ALL BRAND
HITACHI
Dealers/Contractors
UPSPL
GURU HVAC
ABS
MAGNA COOL
AIRCON
VKBS
KNND
PSYCROMETRIC
UNIMECH
SURAJ MANI
24 ASSURE
AHU
1000-3000
3000-5000
5000-8000
>8000
VENTILATION
1000-5000
>5000
Item
Primary Pumps
Qty
Suction side
1
1
1
1
discharge side
1
1
1
1
Secondary Pumps
Item
Butterfly isolation valve
Y-strainer
Suction side
flexible bellows
pressure gauge
discharge side
1
1
1
1
Item
condensor Pumps
Butterfly isolation valve
Y-strainer
Suction side
flexible bellows
pressure gauge
discharge side
Qty
1
1
1
1
Qty
1
1
1
1
Maximum Power
1
1
1
1
Air cooled
Water
Cooled
QxH /6354xeffi
Chillers(AIR/
WATER
COOLED)
Item
IN
butterfly isolation valve
Motorized on/off valve
flexible bellows
Pressure gauge
Test points
Drain valve
Thermowell for BMS
By pass valve with Modulating actuator
out
AHU/FCU
IN
Item
ball valve / butterfly isolation valve
Y-strainer
flexible bellows
Pressure gauge
Temperature gauge
3 way control valve with modulating actuator
Drain valve
Thermowell for BMS
out
Qty
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Qty
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
-Static Pr in inches
ffic- over all efficeincy of the pump 0.75
1 hp = 0.746 kw
STANDARD
NON STANDARD
STANDARD
STANDARD
STANDARD
STANDARD
NON STANDARD
ONLY FOR CHILLER WITH PRIMARY PUMPS
ALONE,BUT IT IS NON STANDARD.
STANDARD
STANDARD FOR CHILLER WITH ONLY SECONDARY PUMPS
STANDARD
STANDARD
STANDARD
STANDARD
NON STANDARD
STANDARD
STANDARD
NON-STANDARD
NON-STANDARD
NON-STANDARD
APPLICABLE ONLY IF SECONDARY PUMPS DOES NOT EXISTS
NON STANDARD
NON STANDARD
STANDARD
NON STANDARD
APPLICABLE ONLY IF SECONDARY PUMPS EXISTS
NON-STANDARD
NON-STANDARD
NON-STANDARD
STANDARD
NON STANDARD
hp = 0.746 kw
conversions
1 hp = 0.746 kw
1 gpm = 0.0631 lps
1 LPS = 15.85 GPM
1 metre = 3.28 feet
1 feet = 30 cm
1 m3 = 1000 litres
1 sq m = 10.86 sq ft
1 l/s = 3.6 m3/hr
I TR = 3.5 KW
12000
1 TR =4.7 HP
4.7
1HP = 0.8 TR
one ton refrigeration
It is the heat removal rate required to freeze one mertric ton of water to ice in 24 hrs.
It is the trem used to indicate the capacity of the refrigeration and air conditioning.
1 TON of refrigeration = 12,000 BTU/Hr = 3000 Kcal/Hr.
1 Kcal = 3.97 BTU
HP = BKW/0.745
BKW = (Q X H / 367.2 X Eff.) x Sp.gravity
Q - m3/hr H - m
m3/hr =3.6 lps
m3/hr =0.06 lpm
m3/hr =0.273 IGPM
m3/hr =4.4 USGPM
H (m) = P x 10 / sp.gravity
P - kg/cm2
3 phase
cos pai=0.91
root 3 = 1.732
i=current(Amp)
1kw
1TR
1TR
1W
1BTU/HR
1.3404825737 hp
12000 BTU/HR
3500 W
3.43 BTU/HR
0.29 W
1 KW
1 hp
1 tr
1 kw
=
=
=
=
2.2 kw
1 hp
1 tr
1TR =
1TR =
1 j/s
1 kj/s
=
=
3024 k cal hr
1 Kcal / s
=
3.5112 KW
1 watts
1 kw
0.84 k cal / s
4.18 Kj/s
1.34 hp
0.746 kw
3.5 kw
0.286 tr
=
=
0.8 tr
1.25 hp
VRF - TOSHIBA
70 - 80 % OF 100 TR (IDU)
100 TR
7.84
11.2
9.8
al cost saving.
be very low -Electrical
d at the same time another compressor can be working (Individual Compresser maintenance is possible )
SET - GENERATER - SINCE STARTING CURRENT REQUIRED FOR CHILLER WILL BE VERY LOW.
d only 1 % of the time in 365 days.
42 % of the time in 365 days.
45 % of the time in 365 days.
nce is possible )
York
Ikw value / TR
others
0.7 0.80 & less
0.65 0.70 & less
0.60 & below 0.60 - 0.65
<0.50 0.50 - 0.55
1.3
1.18
1.15 ?
IPLV - 0.80 - 0.90
IPLV -0.75
full load 1.2(ikw)
1.3
1.2 range
wrty
oh
pm
cont
negtn
G.P
Standard
%
DIVIDE BY factor
1
0.99 1.010101
12.5
0.875 1.154401
10
0.9 1.282668
2
0.98 1.308845
5
0.95 1.377731
30.5
%
wrty
oh
pm
cont
negtn
G.P
1
12.5
10
2
5
30.5
DIVIDE BY
factor
0.99 1.01010101
0.875 1.15440115
0.9 1.28266795
0.98 1.30884485
0.95 1.37773142
balu
nagaraj
THERMOSTATIC EXPANSION
VALVE(FROM PARTHIBAN) BUYING COST
5.5TR
8.5TR
11.5TR
DRIER
prestige
hilton hotel
ERECTION
3750
5500
7500
1000
1000
1000
800
500
ilton hotel
julinrobert
1 AIR CHANGE:
20 air change:
Negative pressure:
Positive pressure:
Kitchen exhaust:
chemical process / fumes removal
Electrical room:
General application (freshness)
Car parking:
Fire / smoke:
Air conditioning:
normal ventilation:
30 - 35 air change
30 - 35 air change
12 air change
10 - 12 air change
8 - 10 air change
15 - 20 air change
8-11 air change
8 air change
Application:
High quantity of air is required
High static pressure
Low or medium quantity of air
low or medium static pressure
AMBIATOR
CFM X 60
VOLUME
(CFM /100)*1.75
No unit
pplied will be lower than the air exhausted. Eg:toilet , kitchen ,flammable fume area etc
pplied will be higher than the air exhausted.eg:good air conditioning systems ,electrical rooms.
SISW BACK WARD CURVED FAN IS GENERALLY PREFERRED FOR KITCHN EXHAUST
DIDW BACK WARD / FORWARD IS GENERALLY PREFERRED FOR FRESH AIR APPLIC
FOR KITCHEN EXHAUST ,FRESH AIR FAN IS CHOOSEN AT 80 % OF EXHAUST FAN
n defined direction without duct. Jet fans are choosen based on cfd analysis.thumb rule 1 jet fan for 2400 sqft ar
Example
EXPLANATION
100
133
ft^2x(ft/min) x60 /
ft x ft xft
Margin %
0.25
100
125
0.20
cal rooms.
0.25 G.P
0.20 G.P
ceiling
floor
total
Rs 300 / sqft
Rs250 / sqft
for removing latent heat ( water vapour from human body due to phase change ) one didicated chiller
ahu ,ducting ,insualtion ,piping is required.
Total heat removed = sensible heat + latent heat
shall be selected to operate at 14 - 19 deg C ,Delta T is 5 deg (power consumption say 0.35 kw /tr is possible)
ge ) one didicated chiller shall be choosen to operate at 7 -12 deg C ,delta T is 5 deg (power consumption say 0
475
770
128
length(m) Nos
2.2
6
slotted
MS
140
350
128
Run Mts
770
770
sup+labour
Rate/length
352
1575
diff
MS/kg (Rs)
75
MS 1 mtr (kg)
3.5
Total
271040
1212750
941710