Versatile Configuration
Most distribution assets are not being monitored, mainly due to space limitations, installation cost and
the cost of the monitoring device itself. The Multilin DGCM is a versatile Field RTU (Remote Terminal Unit)
that can monitor and control a wide range of pole top, pad mount, and underground distribution assets.
This compact solution is designed for easy installation on new equipment and retrofit on installed
assets, making distribution modernization a cost-effective endeavor. The Multilin DGCM supports most
wired and wireless communication architectures along with multiple simultaneous industry standard
communication protocols, resulting in a seamless and straightforward integration into DMS, OMS and
SCADA systems.
Key Benefits
Reliable Hardware
Distribution Substation,
LV Systems
Load Monitoring, Theft Detection
Cost-Effective
Integration
Unsolicited messaging for immediate issue
notification
Rogowski coil option reduces installation time
Integrated cellular modem delivers accessible
communication
Compact Footprint
Scalable solution supports multiple
application needs
Variable options (stand-alone, with or without
HMI, with or without an enclosure) for
situational requirements
Application Overview
Distribution systems have grown rapidly in the past few decades, including
the addition of low carbon technologies, causing increased instances of
system losses and poor supply quality. In order to improve operational
planning, grid efficiency, and reliability, utilities need network or topographic
information, real-time load data, as well as the status of distribution assets,
like transformers and feeders.
RING AND CO
NT
ITO
N
O
L
RO
PO
L E -T
O P E Q UIP
ME
N3
TIO
STA
TO
ING & CO
NT
ITOR
R
ON
M
B
SU
NT
ME
UIP
OL
-TO
LE
SU
PO
BS
TAT
IO
Q
PE
N2
NT
MU
NT S
W I TC H G
EA
MO
R/
A
GE
H
ITC
PO
DE
MU
RN
SW
UND
ERG
T
STA
UB
MS
ND
CAB
LES
RMER MONIT
OR
SFO
N
I
A
TR
NG
TR
FRO
1
ION
ROU
IZI
RM
ERG
R
ME
TH
ER
SFO
AN
UND
NG
ROU
ND
CAB
LES
SU
ION
T
IBU
TR
DIS M
LV YSTE
S
ING & CO
NT
ITOR
R
ON
M
L
TIA
LV
GEDigitalEnergy.com
US
IND
EN
SID
RE
N
CO
RID
D IS
T RIB U TI O N S Y
ST
L
RIA
N
CO
ME
SU
OL
ME
OM
/C
L
CIA
EG
EM
OU
ME
UIP
EQ
/R
D
PA
OP
E-T
Key Benefits
Up to 64 DI
& 32 DO
Up to 6
Voltage
Inputs
1 to 6 Feeders
Overcurrent detection per phase (50, 51) for each feeder to identify
faulted circuits and loads approaching overload levels
Up to 6 Current Inputs
DGCM
DGCM
1 to 6 Feeders
Up to 18 Current Inputs
Key Benefits
Compact, cost-effective fault detector for underground cable networks
Rogowski coil option to enable retrofit installation in space-limited
locations and to reduce the need for outages
Early warning and fault detection per phase (50, 51) for each feeder to
reduce fault location and feeder downtime
Multiple communication (cellular and radio) and protocol options for easy
integration into DMS and SCADA systems
Using the Multilin DGCM on cables enables faster fault detection and
isolation, reducing outages and crew deployment time.
GEDigitalEnergy.com
DGCM
Up to 6 Voltage Inputs
1 to 6 Feeders
Up to 18 Current Inputs
Key Benefits
Real-time load and energy monitoring and profiling of up to 6 feeders (18
individual phases)
Quick retrofit installation especially in tight spaces through Rogowski coil
current sensors or traditional CTs
Cost-effective energy monitoring through direct voltage measurements
up to 400V or via LEA voltage sensors
LV Substation
DGCM
mA Inputs
Key Benefits
Voltage Inputs
Current Inputs
GEDigitalEnergy.com
SWITCHING DEVICE
LINE
A
B
C
A
B
C
LOAD
Key Benefits
Cost-effective automation of installed field equipment (reclosers,
switches, sectionalizers, interchange tie closures, tap changers and
capacitor bank controllers)
DGCM
Overcurrent detection per phase (50, 51) for each feeder to identify
faulted circuits and loads approaching overload levels
Energy monitoring and logging to help theft detection
Remote configuration and firmware updates to simplify fleet
management
FlexLogic to allow for the creation of customized control schemes that
can be used in many pole top applications
Supports direct voltage measurements up to 400V or LEA voltage sensors
for cost-effective monitoring
DGCM
mA Inputs
Voltage Inputs
Key Benefits
Current Inputs
End of line voltage and current measurements to help in short term and
long term operational planning
Energy monitoring and logging to help theft detection
Real-time monitoring of voltage for integrating in Volt/VAr control
schemes
Overcurrent detection with alarm/trip to provide early warning signals of
potential failures
Support for multiple communications technologies including cellular and
private radio networks
Volt/VAr control schemes are better optimized using the Multilin DGCM,
as changes in voltage (real-time) are reported almost immediately
(unsolicited messaging) over most utility protocols.
GEDigitalEnergy.com
Hardware Options
140mm/5.51
Base Unit
(Supports Maximum 2 Modules)
3 Voltage Inputs
Up to 18 Current Inputs (2 Cards)
Up to 32 Digital Inputs and 16 Digital Outputs (2 Cards)
Note : Maximum 2 Cards
150mm/5.91
* Base Unit
Analog Inputs
The Multilin DGCM utilizes many traditional and non-traditional sensors:
Traditional CTs
Traditional PTs
Rogowski Coils
LEA Sensors 0 to 12V Output
Rogowski Coils
Rogowski coils can be used on bare conductors for voltages of up to 600V
and on insulated cables for higher voltages. The use of Rogowski coils
shortens the installation time, reducing outage periods and installation
costs.
Rogowski Coil
GEDigitalEnergy.com
Advanced Integration
The Multilin DGCM employs industry standard communications
technologies, making it one of the easiest and most flexible controllers to
use and integrate into new and existing SCADA and DMS infrastructures.
Remote Communication
Multiple communication ports and protocols allow for remote control and
easy access to device and system information.
The Multilin DGCMs integrated cellular modem eliminates the need for
external wireless devices, reducing infrastructure costs.
GSM/GPRS
MDS iNET-II
MDS TransNet
The Multilin DGCM can be used as an I/O extension for relays or for current and voltage measurements into new and existing SCADA and DMS infrastructures.
Indication LED
RJ45 Ethernet Port
Power Supply
Cellular Antenna
GEDigitalEnergy.com
Fault/Level Detections
The Multilin DGCM offers powerful I/O and programmable logic (FlexLogic)
options for advanced automation and control, reducing the need for and
costs associated with additional programmable controllers and discrete
control devices.
Effective fault isolation is a key feature for grid reliability. The Multilin DGCM
provides early warning of downstream overcurrent and earth faults. It can
be programmed to isolate a faulted segment, either independently or from
remote SCADA systems. The Multilin DGCM also offers control, monitoring
and diagnostics in one integrated and efficient design.
Remote Control
For both operational efficiency and reliability, the Multilin DGCM provides
remote control for operating overhead switches and pad mount switchgear.
The Multilin DGCM can be locally locked to prevent remote control operations
during field maintenance. Capable of providing both local and manual
control of switchgear, the compact size of the Multilin DGCM enables it to fit
into existing outdoor distribution substations where space constraints exist.
Overcurrent Protection
The Multilin DGCM has three set point groups. The activation of the groups
can be done either from SCADA, HMI or via a digital input.
FlexLogic
Instantaneous and time overcurrent functions are available for phase, and
neutral currents. A variety of time curves are provided, including IEEE/
ANSI, IEC A/B/C long time inverse and short time inverse definite time and
user-programmable curves.
FlexLogic in the Multilin DGCM helps reduce costs by providing the ability
to create customized control schemes, minimizing the need for auxiliary
components and wiring. Schemes can be configured with FlexLogic,
specifying what actions need be taken, based on the status of fault
detections or control elements, and inputs driven by connected sensors and
equipment .
1
Save
Restore
Default
AND (2)
AND (3)
AND (2)
BNK1 PH HI IOC OP
CONT IP 1 ON (SWITCH 1 OPEN)
AND (2)
AND (2)
TIME
OR (2)
2
4
AND (3)
= VIRTUAL OP 1 (VO1)
3
CURRENT
GEDigitalEnergy.com
The Multilin DGCM provides a 200 channel RMS recorder for advanced
disturbance diagnostic features. Data recording can be set to record from 1
minute to 60 minute intervals. This significantly reduces the time and cost
associated with troubleshooting power system events and reconstructions.
The data can be immediately analyzed for trends, or stored for archival
purposes.
Power Loss
The Multilin DGCM can detect a power loss condition in each phase of the
power distribution line. Open/close commands are blocked, unless currents
and voltages of each phase fall below minimum set values. When the switch
is closed, the power loss detection of the source side is used to control the
open command execution.
Measurements
The Multilin DGCM provides high accuracy metering and recording of AC
signals, measuring the following key parameters:
Basic Measurements
EVENT
DATE
TIME
53
02/03/2012
16:22:44:103
TOC pickup
52
02/03/2012
16:22:44:220
Loss 01 Power
51
02/03/2012
16:22:45:115
50
02/03/2012
16:22:45:175
AS first shot
49
02/03/2012
16:22:47:680
TOC pickup
48
02/03/2012
16:22:47:710
Loss of Power
47
02/03/2012
16:22:48:132
46
02/03/2012
16:22:48:192
A5 second shot
45
02/03/2012
16:22:48:412
Switch Open
CAUSE OF EVENT
02/25/2013
13:05:21.626000
5hr 0 m
15 hr 0 m
02/25/201313:05:21.626000
02/25/201313:05:21.626000
10 hr 0 s
280.000 (Amps)
160.000 (Amps)
-120.000 (Amps)
Frequency
270.000 (Amps)
190.000 (Amps)
-80.000 (Amps)
230.000 (Amps)
130.000 (Amps)
-100.000 (Amps)
Voltage sag/swell
Current unbalance
198.02.000 (Amps)
113.154.000 (Amps)
-84.866.000 (Amps)
Phase B RMS Current Bank1
190.948.000 (Amps)
134.371.000 (Amps)
-56.577.000 (Amps)
Phase C RMS Current Bank1
162.659.000 (Amps)
91.938.000 (Amps)
-70.721.000 (Amps)
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
The Multilin DGCM data logger helps in better understanding the analog
channel behavior, by sampling at a selectable time interval rate of 1 to 60
minutes.
GEDigitalEnergy.com
Application Notes
EnerVista Launchpad
Wiring Diagrams
FAQs
Service Bulletins
10
GEDigitalEnergy.com
Technical Specifications
POWER SUPPLY
COMMUNICATIONS
SERIAL
Range:
60 to 440 VAC
Nominal Frequency:
50/60 Hz
Burden:
<0.25 VA at 120 V
Accuracy: 0.5% Throughout Range
Voltage Withstand: 2xVn Continuously, 3xVn 10s
RS485 Port:
Baud Rates:
Protocol:
24 to 48 VDC
20 to 60 VDC
ETHERNET (COPPER)
Range:
0 to 10 VAC
Nominal Frequency:
50/60 Hz
Input Impedance:
> 10 M
Accuracy: 0.5% Throughout Range
Voltage Withstand: 2xVn Continuously,
3xVn 10s
USB
Standard Specification:
Data Transfer Rate:
DIGITAL INPUTS
Thresholds:
20 to 64 VDC for Low Range
100 to 240 VAC for High Range
Recognition Time:
1/2 Cycle
Debounce Time: 10 to 100 ms, Selectable,
in Steps of 5 ms
Contact Material:
Operate Time:
Continuous Current:
Make and Carry for 4s:
GPRS
DIGITAL I/O
DIMENSIONS
DIGITAL OUTPUTS
IP67
Opto-Coupled
Up to 115 kbps
Modbus RTU, DNP 3.0,
(IEC 60870-5-101 available
Q4 2015)
Silver-Alloy
10 ms
6A
15 A per ANSI C37.90
Type Tests
TEST DESCRIPTION
LEVELS
STANDARD
TEST DESCRIPTION
IMMUNITY
ESD
LEVELS
STANDARD
Dielectric Strength
EN60255-5
Radiated RF Immunity
Impulse
IEC 61010-1:2010
Radiated RF Immunity
IEEE C37.90.2:2004
Fast Transient
4 kV at 5 kHz
IEC 61000-4-4:2012/
IEC60255-22-4
Surge
2 kV
IEC 60255-22-5
Conducted RF Immunity
IEC 61000-4-8:2001
Voltage Dip
0% during 1 cycle
40% during 10/12 cycles
70% during 25/30 cycles
80% during 250/300 cycles
IEC 61000-4-11:2004
Voltage Interruption
IEC 61000-4-11:2004
Radiated RF Emission
Conducted RF Emission
ENVIRONMENTAL
Operating temperature: 40C to + 65C as per IEC 60068
Relative humidity cyclic: IEC 60068-2-30; 55C 95% humidity
MECHANICAL
Sinusoidal vibration: IEC 60068-2-6:2007 Class 1
Shock and bump: IEC 60068-2-27:2008 Class 1
Seismic: IEC 60068-3-3:1991 Class 2
MISCELLANEOUS
EMISSIONEN
Ingress of solid objects and water: IEC 60529:2007 IP44 (with external enclosure) NEMA 3/4
for cabinet
Resistance to mechanical stresses: IEC 61010-1:2010 (Paragraph 8)
Protection against the spread of fire: IEC 61010-1:2010 (Paragraph 9)
IEC 61000-3-2 (2008): Limits for harmonic current emmissions
IEC 61000-3-3 (2008): Limitation of voltage changes, voltage fluctuations and flicker in public
low-voltage supply systems
GEDigitalEnergy.com
11
Ordering Codes
DGCM FIELD RTU
DGCM
Base type
DGCM
Description
Field RTU
Power Supply
Modules
Controller
None
1
2
Wireless Radios
No External Communications
Rogowski Coil
ROGS
Rogowski Coil
Sensors
ROGS
Digital Energy
650 Markland St.
Markham, ON
Canada L6C 0M1
Toll Free (NA Only): 1-800-547-8629
Tel: 905-927-7070
Fax: 905-927-5098
[email protected]
GEDigitalEnergy.com
IEC is a registered trademark of Commission Electrotechnique Internationale.
IEEE is a registered trademark of the Institute of Electrical Electronics Engineers, Inc.
ANSI is a registered trademark of American National Standards Institute, Incorporated.
Microsoft is a registered trademark of Microsoft Corporation.
Modbus is a registered trademark of Schneider Automation.
GE, the GE monogram, Multilin, FlexLogic, EnerVista, MDS and PowerOn are trademarks of the
General Electric Company.
GE reserves the right to make changes to specifications of products described at any time
without notice and without obligation to notify any person of such changes.
Copyright 2015, General Electric Company. All Rights Reserved.
GEA-12715C(E)
English
150209