False Air - Measuerment Overview

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 11
At a glance
Powered by AI
The passage discusses different methods for calculating false air intake in kilns using oxygen measurements and accounting for moisture.

Two methods are described for calculating false air - one using oxygen measurements on a dry basis and one using measurements on a wet basis.

The parameters used in the calculations include inlet and outlet gas volumes and moistures, inlet and outlet oxygen levels, and the assumed oxygen content of false air.

PLANT

Oxygen Measurements %

Kiln Number
Exit Bottom
Stage Cyclone

P/H Exit

Stack
Direct
Operation

Stack
Compound
Operation

Definitions:
Direct - kiln running without mills
Compound - kiln running with all mills
Assumptions for Gas Moisture Content
Preheater Gases
Stack Direct
Stack Compound
Coal Mill Stack
Air

5
15
12
15
1

%
%
%
%
%

Note) 1. Assume Bottom Stage Cyclone Exit and P/H Exit gas moisture is same (False air moisture is not considered)

Coal Mill Stack

O2 Measured
Dry or Wet

alse air moisture is not considered)

Date Measured

False Air %P/H Volume Wet


False Air
Preheater to Preheater to
Preheater
Stack Direct
Stack
Compound

Coal Mill
System False
Air %
Preheater
Gases Used

Dry

Bucket Elevator

Vertical

Yes

Baghouse

Wet

Air Lift

Ball Mill

No

Electro-Filter

Pump

Tandem Hammer Mill

3
4
5
6
7
8
A
C
D

Roller Press

Electro-Filter

PLANT

Kiln Number

Number P/H
Cyclone Stages

Design of Raw
Meal Feed to
Preheater

Pump type Kiln Raw Mill Design


Feed Transport
Air Volume
nm3/hr

Number of Raw
Mill Circuits per
Kiln

Separate Raw
Mill and Filter
Fans

Main Filter
Design

Coal Mill Design

Bucket EleVertical

Yes

Air Lift

Ball Mill

No

Pump

Tandem Hammer Mill

4
5
6
7
8
A
B
C
D

Roller Press

Baghouse
Electro-Filter

False Air Calculation using Oxygen Measurements on Dry Basis

Oxygen measurements on Dry Basis


False Air
Volume
Oxygen
Moisture
Inlet Gases
Volume (wet) V
Oxygen
O2i
Moisture
mi

x
21 %
ma %
Outlet gases
Volume (wet) (V*(100-mi)+x*(100-ma))/(100-mo)
Oxygen
O2o
Moisture
mo

SYSTEM

Oxygen balance on dry basis


O2 in
Inlet gases
False Air

O2 out
V*(100-mi)/100*O2i
x*21*(100-ma)/100

Outlet gases (V*(100-mi)/100+x*(100-ma)/100)*O2o

Setting equal and rearranging


x*(21*(100-ma)/100-O2o*(100-ma)/100)=V*(100-mi)/100*(O2o-O2i)
x/V = (100-mi)*(O2o-O2i)/((100-ma)*(21-O2o))

False Air Calculation using Oxygen Measurements on Wet Basis

Oxygen measurements on Wet Basis


False Air
Volume
Oxygen
Moisture
Inlet Gases
Volume (wet) V
Oxygen
O2i
Moisture
mi

x
21 %
ma %
Outlet gases
Volume (wet) (V*(100-mi)+x*(100-ma))/(100-mo)
Oxygen
O2o
Moisture
mo

SYSTEM

Oxygen balance on wet basis


O2 in
Inlet gases
False Air

O2 out
V*O2i
x*21

Outlet gases (V*(100-mi)+x*(100-ma))/(100-mo)*O2o

Setting equal and rearranging


x*(21-O2o*(100-ma)/(100-mo))=V*(O2o*(100-mi)/(100-mo)-O2i)
x/V=(O2o*(100-mi)/(100-mo)-O2i)/(21-O2o*(100-ma)/(100-mo))