Interroll Zone Control Card
Interroll Zone Control Card
Interroll Zone Control Card
The ZoneControl is the single zone control for the RollerDrive EC310. The ZoneControl can be used to create
stand-alone, zero pressure accumulation conveyors which require no higher-order control. Additional functions and
communication to upstream and downstream conveyors can be provided via digital inputs and outputs (I/Os). No
DriveControls are needed to set up a conveyor as the ZoneControls include their functions.
Design
information
Configuration
Functions
106
Electrical data
Rated voltage
Temporarily permissible voltage range
Permissible voltage undulation
Rated current
Max. start-up current
Fuse
Protection rate
Ambient conditions
Ambient temperature in operation
Ambient temperature during transport and storage
Max. temperature change
Max. air humidity
Cable cross-sections
Power Supply
Inputs / Outputs (I/O)
ZoneControl
24V DC
18to26V DC
3 %, recommended: < 1 %
2.0A
5.0A
present, non-replaceable
IP20
0to+40C
-20to+75C
1 % in 3 h; 2 cycles in compliance with IEC 60068-2-14
90 %, non-condensing
Speed adjustment
-- DIP switch (per accumulation zone)
-- External analogue signal (for the entire conveyor system)
The effective current in the application depends on the conveyor weight, conveyor speed and number of cycles.
Switching a second RollerDrive, status reading, starting and stopping of individual zones via I/Os
DriveControls Overviewp100
DriveControl
Technical Data
Product Description
Properties
RollerDrive EC310p88
Refer to the Planning Section from p 168 onwards for help with planning and design
107
Zo n eC o n t r o l
Dimensions and Connections
ZoneControl
Power
130
118
DriveControl
1
2
Earth
+24 V DC
1
2
3
4
5
6
7
8
1
4
6.5
55
42
Pos. 5
Inputs/Outputs
6.5
6
3
108
2.5
24
Pos. 1
Pos. 2
Pos. 3
RollerDrive Connection
1
2
3
4
5
+24 V DC
Direction of rotation
Earth
Fault input
Analogue speed output
1
2
3
+24 V DC
Sensor signal input
Earth
1
2
3
+24 V DC
Sensor signal input
Earth
Construction
Start sensor
Zone sensor
108
DriveControls Overviewp100
RollerDrive EC310p88
1 Zone 1
6 Zone sensor
2 Zone 2
7 RollerDrive
3 Zone 3
4 Conveyor direction
9 Peer-to-peer connection
5 ZoneControl
10 Material to be conveyed
Refer to the Planning Section from p 168 onwards for help with planning and design
109