Thiết bị ghép kênh PCM

Download as pdf or txt
Download as pdf or txt
You are on page 1of 29

Loop-AM3440

Access DCS-MUX
AM3440-A

Description
The Loop-AM3440-A/B/C series are Access DCS-MUXs
that combine various digital access interfaces into E1 or T1
lines for convenient transport and switching. The
Loop-AM3440 Access DCS-MUX provides access for a
variety of TDM, IP, and voice interfaces detailed on the
next page. These interfaces are compatible with other
Loop products. Using these products, a DTE interface can
be extended over copper wire pairs or any E1/T1 transport
facility. Each Quad E1/T1 plug-in card can have as many
as DS0 124/96 time slots from G.SHDSL, RS232, X.21,
V.35, V.36 and EIA530 / RS449 interfaces, which can be
multiplexed to fill 4 E1/T1 lines. The AM3440 also supports
fiber optical plug-in cards, which can be used to aggregate
up to 4 E1 channels onto a single fiber optical interface to
connect with other AM3440 devices or with the O9310-E1.

AM3440-B

AM3440-C

Each of the 3 models of AM3440, the A, the B, and the C,


has a number of plug-in slots in single slot size and mini
size. Card size to slot compatibility is detailed on the next
page.

Features
y
y
y
y
y
y
y
y
y
y
y
y

Full front access (ETSI) Shelf


Support of DS0 DACS (Digital Access Cross-Connect
System) with full cross-connect
Dual controller, dual power with load sharing
1 for 1 protection via Y-BOX
1 for 1 protection, E1, T1, FOM
PDH ring protection, QE1, QT1, FOM, Mini QE1
Console, Telnet, and Inband management support
SNMP v.1 and v.3
Craft interface port for connection to external Intelligent
Front Panel
Compatible to a SNMP based GUI network management
system and supported by LoopView and Loop iNMS
Three types of chassis available: AM3440-A, AM3440-B,
AM3440-C
All the plug-in cards are hot-pluggable
Item
AM3440-A AM3440-B AM3440-C
Chassis

5U

2.5U

3U

# of Mini-slots

# of Single slots

12

Maximum E1
Channels

64

28

36

Maximum T1
Channels

52

16

24

Cross-Connect
Backplane
Capacity

128 Mbps

56 Mbps

72 Mbps

This unit is a full cross-connect and can act as a mini


DACS: one or more of the WAN ports can be used as a
Drop & Insert function with fractional E1/T1 lines, which
can be muxed into a full E1/T1 line.
Redundancy is available in dual CPU controller and power
supply options, making it an excellent fit for critical
applications. The chassis does not need fan cooling, and
thus does not have a fan, though an external fan tray is
available.
The AM3440 supports local control and diagnostics by
using an external 2-line by 40-character LCD display and
keypads, or by using a VT-100 terminal connected to the
console port. The AM3440 also supports Ethernet, Telnet,
and SNMP, so that it can be controlled and diagnosed from
remote locations. An in-band management channel with
GUI is available. In addition to the LCD display, there is
LED indication for all plug-in cards.
The AM3440 consists of a rugged reinforced aluminum
chassis, giving this equipment a more durable structure
and a longer physical life.

Loop-AM3440 cards:
The Mini-Slot Cards plug into the Mini-Slots of the AM3440. The Single-Slot Cards plug into single slots. The
Dual-Slot Cards plug into two adjacent single slots.
Plug-in cards
AM3440-A AM3440-B AM3440-C
1-channel E1 (Single E1 interface)

1-channel T1 (Single T1 interface)

Mini Quad E1 (Four E1 interfaces)

1-channel E1 ATM/Frame Relay


D
D
D
1-channel T1 ATM/Frame Relay
D
D
D
Fiber optical interface

1-channel X.21

1-channel V.35

1-channel RS232

Mini-Slot
1-channel EIA530

Quad 2W/4W E&M (Four E&M voice interfaces)

QFXS/QFXO (Four FXS/FXO voice interfaces)

2-LAN port/32 WAN port Router

2-LAN port/64 WAN port Router-A

3-channel Terminal Server

Phone Line Monitor (PLM) cards

1-channel OCU-DP

3-channel E1

4-channel E1

4-channel T1

8-channel OCU-DP

2-channel G.SHDSL (2 pairs) w/o line power

4-channel G.SHDSL (1 pair) w/o line power

8-channel G.703 card at 64 Kbps data rate

8-channel Dry Contact I/O

8-channel Dry Contact I/O type B

8-channel 2W/4W E&M

12-channel FXS

Single-Slot
12-channel FXO

12-channel Magneto

Conference card

1-channel low speed optical (C37.94)

4-channel low speed optical (C37.94)

8-channel RS232 with X.50 subrate

8-LAN-port/ 64-WAN-port Router-B

4-channel TDMoE

8-channel Data Bridge

1FOMA

8-channel UDTEA

6-channel X.21/V.11

6-channel V.35

6-channel V.36

6-channel EIA530/RS449 card

Dual-Slot
2-channel G. SHDSL (2 pairs) with line power

4-channel G. SHDSL (1 pair) with line power

24-channel FXS

24-channel FXO

Note: = Supported
= Not supported
* = Future Option
D= Discontinued

Ordering Information
To specify options, choose from the list below:
Note:
1. RoHS compliant units are identified by the letter G appearing immediately at the end of ordering code.
2. AM3440 chassis types:
AM3440-CHA: 5U chassis with 128 Mb/s cross-connect capacity backplane
AM3440-CHB: 2.5U chassis with 56 Mb/s cross-connect capacity backplane
AM3440-CHC: 3U chassis with 72 Mb/s cross-connect capacity backplane
Model
(non RoHS compliant)
Main Unit
Loop-AM3440-CHA

Model
(RoHS compliant)
Loop-AM3440-CHA-G

Loop-AM3440-CHB

Loop-AM3440-CHB-G

Loop-AM3440-CHC

Loop-AM3440-CHC-G

Main Unit for DS0 SNCP function


Loop-AM3440-CHAJ
Loop-AM3440-CHAJ-G
Loop-AM3440-CHCJ

Loop-AM3440-CHCJ-G

CPU Module
Loop-AM3440-CCA-T

Loop-AM3440-CCA-T-G

Loop-AM3440-CCA-E

Loop-AM3440-CCA-E-G

Mini Plug-in Module (Select 1 to 4 cards from list below)


Loop-AM3440-E75-G
Loop-AM3440-E75

Description

Wideband Main Unit without CPU,


power and plug-in cards
Wideband Main Unit without CPU,
power and plug-in cards
Wideband Main Unit without CPU,
power and plug-in cards
Wideband Main Unit without CPU,
power and plug-in cards, applicable to
use with 3E1 card
Wideband Main Unit without CPU,
power and plug-in cards, applicable to
use with 3E1 card

Note

AM3440-A, B, C type Chassis.


19/23 ear mount included.
Note: For other ear mount requests,
please contact your nearest Loop
sales representative.

Must order AM3440-CHAJ for DS0


SNCP function
Must order AM3440-CHCJ for DS0
SNCP function

CPU card with T1 External Clock


(order two for redundancy)
CPU card with E1 External Clock
(order two for redundancy)

Loop-AM3440-T1
Loop-AM3440-M4E75

Loop-AM3440-T1-G

Loop-AM3440-M4E120

Loop-AM3440-M4E120-G

Loop-AM3440-AFRE

Loop-AM3440-AFRE-G

Loop-AM3440-AFRT

Loop-AM3440-AFRT-G

Loop-AM3440-RT

Loop-AM3440-RT-G

Loop-AM3440-RTA

Loop-AM3440-RTA-G

Loop-AM3440-FOM-opt

Loop-AM3440-FOM-opt-G

Loop-AM3440-TS

Loop-AM3440-TS-G

Loop-AM3440-1X21

Loop-AM3440-1X21-G

1-channel of E1plug-in card w/ 75


ohm
1-channel of E1 plug-in card w/ 120
ohm
1-channel T1 plug-in card
Mini Quad E1 plug-in card
Includes a three meter conversion
with 75 ohm
cable, please make a note on which
cable you need.
(Loop-ACC-CAB-DB25M300-8BNCM or
Loop-ACC-CAB-DB25M300-8BNCF)
Mini Quad E1 plug-in card
Includes a three meter conversion
with 120 ohm
cable (Loop-ACC-CAB-DB25M300-4RJ48M)
E1 Frame Relay to ATM
inter-working or Frame Relay to
Frame Relay concentration plug-in
card
Discontinued
T1 Frame Relay to ATM inter-working
or Frame Relay to Frame Relay
concentration plug-in card
2-LAN ports/32 WAN port
Router/Bridge plug-in card
2-LAN ports/64 WAN port
router/bridge plug-in card
Fiber Optical plug-in card
For opt option, please refer to the
table below for detail information
3-chanel Terminal Server plug-in
Includes a one meter conversion
card
cable (Loop-ACC-CAB-DB44M
-100- 2DB25F-1DB09F-TS)
1-channel X.21 plug-in card

Loop-AM3440-1RS232

Loop-AM3440-1RS232- G

1-channel RS232 plug-in card

Loop-AM3440-E120

Loop-AM3440-E120-G

Loop-AM3440-M4E75-G

Loop-AM3440-1V35

Loop-AM3440-1V35- G

1-channel V.35 plug-in card

Loop-AM3440-1E530

Loop-AM3440-1E530- G

Loop-AM3440-1ODP

Not available

1-channel EIA530 plug-in card


1 port OCU-DP Interface card

Loop-AM3440-Q2EM-m-Tn-x

Loop-AM3440-Q4EM-m-Tn-x

AM3440-CHB and AM3440-CHC


only
Limited Quantity
Loop-AM3440-Q2EM-m-Tn-x-G Quad 2 Wire E&M voice plug-in card AM3440-CHB and AM3440-CHC
only

Loop-AM3440-Q4EM-m-Tn-x-G Quad 4 Wire E&M voice plug-in card

Quad FXS voice plug-in card

Loop-AM3440-QFXS-x-pt

Loop-AM3440-QFXS-x-pt-G

Loop-AM3440-QFXS-M-x-pt

Loop-AM3440-QFXS-M-x-pt-G Quad FXS with MP 16 KHz voice


plug-in card

Loop-AM3440-QFXS-M12-x-pt Loop-AM3440-QFXS-M12-x-pt- Quad FXS with MP 12 KHz voice


plug-in card
G
Loop-AM3440-QFXS-GS-x-pt
Loop-AM3440-QFXS-GM-x-pt

Loop-AM3440-QFXS-GS-x-pt- Quad FXS with GS plug-in card


G
Loop-AM3440-QFXS-GM-x-pt- Quad FXS with GS and MP
16 KHz voice plug-in card
G

Where
m = B for normal E&M or TO
(transmission only)
= A for tandem operation
n = 1 to 5 E&M Signaling Type
= O for TO (transmission only)
For m, n and x option, please refer to
the table below for detail information
AM3440-CHB and AM3440-CHC
only
GS = Ground Start
MP = Metering Pulse Transmit 12/16
KHz
pt=power type
For x option, please refer to the table
below for detail information
For pt option, please refer to the table
below fro detail information
QFXS-GM includes all QFXS card
functions

Loop-AM3440-QFXO-x
Loop-AM3440-QFXO-M-x
Loop-AM3440-QFXO-M12-x
Loop-AM3440-QFXO-GS-x
Loop-AM3440-QFXO-GM-x

Quad FXO voice plug-in card


Quad FXO with MP 16 KHz voice
plug-in card
Loop-AM3440-QFXO-M12-x-G Quad FXO with MP 12 KHz voice
plug-in card
Loop-AM3440-QFXO-GS-x-G Quad FXO with GS plug-in card
Loop-AM3440-QFXO-GM-x-G Quad FXO with GS and MP
16 KHz voice plug-in card
Loop-AM3440-QFXO-x-G
Loop-AM3440-QFXO-M-x-G

AM3440-CHB and AM3440-CHC


only
GS = Ground Start
MP = Metering Pulse Receive
12/16 KHz
For x option, please refer to the
table below for detail information
QFXO-GM includes all QFXO card
functions

Loop-AM3440-PLM(A)

Not available

Loop-AM3440-PLM(B)

Not available

Phone Line Monitor (A) Line plug-in Need to order in pair


card with phone line monitor
Available in AM3440-B/C only
Phone Line Monitor (B) Monitor
plug-in card

Single Slot Plug-in Module


Not available

Loop-AM3440-8UDTEA-G

8-port universal data interface card


that supports RS232/RS422/RS485
DCE interface via software
configurable

Not available

Loop-AM3440-3E1-cc-G

3-channel E1 plug-in card with DS0


(64K bps) SNCP protection
Note: DS0 SNCP protection only
support E1 frame mode

Order with Loop-AM3440-CHAJ


or Loop-AM3440-CHCJ ONLY
For cc option, please refer to the
table below for detail information
For controller hardware version J and
software version 8.02.01 or newer
versions.

Not available

Loop-AM3440-TDMoE-PPM-G

TDMoE card with 2 GbE combo


interfaces and 2 Ethernet interfaces
(10/100/1000BaseT) plug-in module
Support G.823 Traffic

Not available

Loop-AM3440-TDMoE-PPB-G

TDMoE card with 2 GbE combo


interfaces and 2 Ethernet interfaces
(10/100/1000BaseT) plug-in module
Support G.823 Synchronization

Loop-AM3440-4E1-cc
Loop-AM3440-4T1
Loop-AM3440-2GH

Loop-AM3440-4E1-cc-G
Loop-AM3440-4T1-G
Loop-AM3440-2GH-G

Loop-AM3440-4GH

Loop-AM3440-4GH-G

Loop-AM3440-8CD

Loop-AM3440-8CD-G

Loop-AM3440-8DC

Loop-AM3440-8DC-G

4-channel E1 plug-in card


For cc option, please refer to the
table below for detail information
4-channel T1 plug-in card
2-channel G.SHDSL plug-in card (2
pair)
4-channel G.SHDSL plug-in card (1
pair)
8-channel G.703 plug-in card at 64
Kbps data rate
8-channel dry contact plug-in card
with maximum voltage 100 Vdc or
250 Vac

Not available

Loop-AM3440-8DCB-G

8-channel dry contact type B plug-in


card with maximum voltage 220 Vdc
or 250 Vac

Loop-AM3440-1C37

Loop-AM3440-1C37-G

1- channel C37.94 plug-in card

Loop-AM3440-4C37

Loop-AM3440-4C37-G

4- channel C37.94 plug-in card

Loop-AM3440-ODP

Not available

8-channel OCU-DP plug-in card

Loop-AM3440-8RS232-RJ

Loop-AM3440-8RS232-RJ-G

8-port RS232 plug-in card with X.50


subrate multiplexing scheme and
X.54 encoding, with 8 RJ48
connectors for 8 RS232 Async ports

Loop-AM3440-8RS232-DB

Loop-AM3440-8RS232-DB-G

8-port RS232 plug-in card with X.50


subrate multiplexing scheme and
X.54 encoding, with 2 RJ48
connectors and 2 DB44 connectors
for Async and Sync ports

Not available

Loop-AM3440-8DBRA-RJ-G

8-channel data bridge plug-in card,


with 8 RJ48 connectors for 8 data
bridge Async ports

Not available

Loop-AM3440-8DBRA-DB-G

8-channel data bridge plug-in card,


with 2 RJ48 connectors and 2DB44
connectors for 8 data bridge Async
ports

Loop-AM3440-RTB

Loop-AM3440-RTB-G

8-LAN ports/64 WAN ports


router/bridge plug-in card

Not available
Loop-AM3440-1FOMA-opt-G

1FOMA Fiber Optical Interface with


1x9 optical port

For AM3440-CHA only.


Limited Quantity

Two conversion cables are included


(DB44 connector to two DB25 and
one DB9 connector;
(Loop-ACC-CAB-DB44M-1002DB25F-1DB09F-DB).

Two conversion cables are included


(DB44 connector to two DB25 and
one DB9 connector;
(Loop-ACC-CAB-DB44M-1002DB25F-1DB09F-DB).
For controller hardware version F and
software version 6.05.02 or newer
versions.
For opt option, please refer to the
table below for detail information
For controller hardware version F and
software version V8.15.01 or newer
versions.

Not available

Loop-AM3440-CONF-G

Conference plug-in card with two


RS232 data ports, two FXS ports
and two E&M ports

Loop-AM3440-8EM-x

Loop-AM3440-8EM-x-G

8-channel 2W/4W E&M plug-in card For x option, please refer to the
with 8 RJ45
table below for detail information

Loop-AM3440-12FXS-sn-pt

Loop-AM3440-12FXS-sn-pt-G

12-channel FXS plug-in card with


600/900 Impedance, Battery
Reverse, Loop Start and PLAR.
Without Ground Start and Metering
Pulse. Used with 12 RJ11.

Loop-AM3440-12FXS-P-sn-pt

Loop-AM3440-12FXS-P-sn-pt- 12-channel FXS plug-in card with


600/900 Impedance, Battery
G
Reverse, Loop Start, PLAR and
[PLAR bit programmable]. Without
Ground Start and Metering Pulse.
Used with 12 RJ11.

Loop-AM3440-12FXS-M-sn-pt

Loop-AM3440-12FXS-M-snpt-G

12-channel FXS plug-in card with


600/900 Impedance, Battery
Reverse, Loop Start, PLAR and
[Metering Pulse]. Used with 12
RJ11.

12FXS-GMP includes all FXS card


functions

Loop-AM3440-12FXS-MPPsn-pt-G

12-channel FXS plug-in card with


600/900 Impedance, Battery
Reverse, Loop Start, PLAR, [PLAR
bit programmable] and [Metering
Pulse]. Used with 12 RJ11.

pt= power type.

Loop-AM3440-12FXS-MPPsn-pt

12-channel FXS plug-in card with


600/900 Impedance, Battery
Reverse, Loop Start, PLAR and
[Ground Start]. Used with 12 RJ11.

For controller hardware version F and


software version 7.05.01 or newer
versions.

For sn option, please refer to the


table below for detail information

For pt option, please refer to the


table below for detail information

Loop-AM3440-12FXS-GSsn-pt

Loop-AM3440-12FXS-GSsn-pt-G

Loop-AM3440-12FXS-GMsn-pt

Loop-AM3440-12FXS-GM-sn-p 12-channel FXS plug-in card with


600/900 Impedance, Battery
t-G
Reverse, Loop Start, PLAR,
[Ground Start] and [Metering Pulse].
Used with 12 RJ11.

Loop-AM3440-12FXS-GMPsn-pt

Loop-AM3440-12FXS-GMPsn-pt-G

12-channel FXS plug-in card with


600/900 Impedance, Battery
Reverse, Loop Start, PLAR, [PLAR
bit programmable], [Ground Start]
and [Metering Pulse]. Used with 12
RJ11.

Loop-AM3440-12FXO

Loop-AM3440-12FXO-G

Loop-AM3440-12FXO-M

Loop-AM3440-12FXO-M-G

Loop-AM3440-12FXO-GS

Loop-AM3440-12FXO-GS-G

Loop-AM3440-12FXO-GM

Loop-AM3440-12FXO-GM-G

12-channel FXO plug-in card with


600/900 Impedance, Battery Reverse
and Loop Start. Without Ground Start
and Metering Pulse. Used with 12
RJ11.
12-channel FXO plug-in card with
600/900 Impedance, Battery
Reverse, Loop Start and [Metering
12FXO-GM includes all FXO card
Pulse]. Used with 12 RJ11.
functions
12-channel FXO plug-in card with
600/900 Impedance, Battery
Reverse, Loop Start and [Ground
Start]. Used with 12 RJ11.
12-channel FXO plug-in card with
600/900 Impedance, Battery
Reverse, Loop Start, [Ground Start]
and [Metering Pulse]. Used with 12
RJ11.

The IEEE1613 standard applies to


AM3440-CHA only

Loop-AM3440-12MAG-A-1G-x

Loop-AM3440-12MAG-A-1G-x
-G

12-channel Magneto ring-one-time


plug-in module w/ L1. GND

Loop-AM3440-12MAG-A-12-x

Loop-AM3440-12MAG-A-12-x
-G

12-channel Magneto ring-one-time


plug-in module w/ L1, L2

Loop-AM3440-12MAG-A-1G2-x Loop-AM3440-12MAG-A-1G2-x 12-channel Magneto ring-one-time


plug-in module w/ L1, L2, and L1.
-G
GND
Loop-AM3440-12MAG-1G-x

Loop-AM3440-12MAG-1G-x-G

Loop-AM3440-12MAG-12-x

Loop-AM3440-12MAG-12-x-G

Loop-AM3440-12MAG-1G2-x

This card can be used in


AM3440-A/B/C only.
12MAG-A-1G2 includes all function
of 12MAG-A cards.

For x option, please refer to the


table below for detail information
12-channel Magneto plug-in module This card can be used in
w/ L1. GND
AM3440-A/B/C only.

12-channel Magneto plug-in module


12MAG-1G2 includes all function of
w/ L1, L2
MAG cards.
Loop-AM3440-12MAG-1G2-x-G 12-channel Magneto plug-in module
w/ L1, L2, and L1. GND
For x option, please refer to the
table below for detail information

Dual Slot Plug-in Module


Loop-AM3440-6X21A

Loop-AM3440-6X21A-G

6-channel X.21/V.11 plug-in card


with DB15S connector

Loop-AM3440-6V35A

Loop-AM3440-6V35A-G

6-channel V.35 plug-in card with


DB25S connector via conversion
cable to M34
(2M bits per channel)

Loop-AM3440-6V36A

Loop-AM3440-6V36A-G

6-channel V.36 plug-in card with


DB25 connector via conversion
cable to DB37

Loop-AM3440-6E530A

Loop-AM3440-6E530A-G

6-channel EIA530 plug-in card


with DB25 connector

Loop-AM3440-6RS449A

Loop-AM3440-6RS449A-G

6-channel EIA530/RS449 plug-in


card with DB25 connector via
conversion cable to DB37

Includes a 30 cm conversion cable


(Loop-ACC-CAB-DB25M-30-1DB37
F)

Loop-AM3440-2GHL

Not available

2-channel G.SHDSL plug-in card


with line power source (140 Vdc,
110mA), (2 pair)

For AM3440-CHA only


Factory installed option available
with -48 Vdc, -125Vdc powered
chassis only.
With line power, takes 2 DTE slots
per card.

Loop-AM3440-4GHL

Not available

4-channel G.SHDSL plug-in card


with line power source (190 Vdc,
60mA), (1 pair)

Fan tray required.


For AM3440-CHA only
Factory installed option available
with -48 Vdc,-125Vdc powered
chassis only.
With line power, takes 2 DTE slots
per card.

Loop-AM3440-24FXS-sn-pt

Loop-AM3440-24FXS-P-sn-pt

Loop-AM3440-24FXS-sn-pt-G

24-channel FXS plug-in card with


600/900 Impedance, Battery
Reverse, Loop Start and PLAR.
Without Ground Start and
Metering Pulse

Loop-AM3440-24FXS-P-sn-pt-G 24-channel FXS plug-in card with


600/900 Impedance, Battery
Reverse, Loop Start, PLAR and
[PLAR bit programmable].
Without Ground Start and
Metering Pulse

Fan tray required.


24FXS-GMP includes all FXS card
functions.
pt= power type

For sn option, please refer to the


table below for detail information
For pt option, please refer to the
table below for detail information

Loop-AM3440-24FXS-M- sn-pt Loop-AM3440-24FXS-M- sn-pt-G 24-channel FXS plug-in card with


600/900 Impedance, Battery
Reverse,
Loop Start, PLAR and
[Metering Pulse].

The IEEE1613 standard applies to


AM3440-CHA only

Loop-AM3440-24FXS-MPPsn-pt

Loop-AM3440-24FXS-MPPsn-pt-G

24-channel FXS plug-in card with


600/900 Impedance, Battery
Reverse, Loop Start, PLAR,
[PLAR bit programmable] and
[Metering Pulse].

Loop-AM3440-24FXS-GSsn-pt

Loop-AM3440-24FXS-GSsn-pt-G

24-channel FXS plug-in card with


600/900 Impedance, Battery
Reverse, Loop Start, PLAR and
[Ground Start].

Loop-AM3440-24FXS-GMsn-pt

Loop-AM3440-24FXS-GMsn-pt-G

24-channel FXS plug-in card e


with 600/900 Impedance, Battery
Reverse, Loop Start, PLAR,
[Ground Start] and [Metering
Pulse].

Loop-AM3440-24FXS-GMPsn-pt

Loop-AM3440-24FXS-GMPsn-pt-G

24-channel FXS plug-in card with


600/900 Impedance, Battery
Reverse, Loop Start, PLAR,
[PLAR bit programmable],
[Ground Start] and [Metering
Pulse].

Loop-AM3440-24FXO

Loop-AM3440-24FXO-G

24-channel FXO plug-in card with


600/900 Impedance, Battery
Reverse and Loop Start.
Without Ground Start and
[Metering Pulse].

Loop-AM3440-24FXO-M

Loop-AM3440-24FXO-M-G

Loop-AM3440-24FXO-GS

Loop-AM3440-24FXO-GS-G

24-channel FXO plug-in card with


600/900 Impedance, Battery
Reverse, Loop Start and [Metering
Pulse].
24FXO-GM includes all FXO card
functions.
24-channel FXO plug-in card with
600/900 Impedance, Battery
Reverse, Loop Start and
[Ground Start].

Loop-AM3440-24FXO-GM

Loop-AM3440-24FXO-GM-G

24-channel FXO plug-in card with


600/900 Impedance, Battery
Reverse, Loop Start, [Ground
Start] and [Metering Pulse].

Accessories
Power Module
Loop-AM3440-SD

Loop-AM3440-SD-G

Loop-AM3440-S5

Loop-AM3440-S5-G

Loop-AM3440-SD125

Loop-AM3440-SD125-G

Single -48 Vdc (-36 to -75 Vdc)


For AM3440-CHA only
Power Module (100W)
For shared redundancy, order 2 single DC.
Single -48 Vdc (-36 to -75 Vdc)
Power Module (150W)
Single -125 Vdc (-40 to -150 Vdc) For AM3440-CHA only
Power Module (100W)
For shared redundancy, order 2 single DC
If the user orders -125 Vdc power module,
the maximum number of cards allowed in
slot 1 to 12 is:
Four 12-channel FXS
Nine 12-channel Magneto
Eleven 8-channel 2W/4W E&M
Six 8-channel OCU-DP
Two 4-channel G. SHDSL
(1 pair) with line power
Three 2-channel G. SHDSL (2 pairs)
with line power
Two 24-channel FXS
There are no limitations for other plug-in
cards in slot 1 to 12.
There are no limitations for any plug-in
cards in slot A to D.

Loop-AM3440-S524

Loop-AM3440-S524-G

Single -24 Vdc (-18 to -36 Vdc)


Power Module (150W)

Loop-AM3440-SDB

Loop-AM3440-SDB-G

Single -48 Vdc (-36 to -75 Vdc)


Power Module (100W)

Loop-AM3440-SAB

Loop-AM3440-SAB-G

Single AC plug-in power supply


(100 to 240 Vac, 50/60 Hz)

For power consumption details, please


refer to AM3440-A Users Manual.
For AM3440-CHA only
Cannot be used with MAG card.
For AM3440-CHB/CHC
For shared redundancy, order 2 single DC.
For AM3440-CHB/CHC
For AC, no redundancy
Choose an appropriate power cord

Mounting Ear
19/23 ear mounts

A pair of 19/23 ear mounts is supplied as part of standard package.


Note: For other sizes, please contact your nearest Loop sales representative.

Users Manual
Loop-AM3440-UM

Users Manual (optional, paper copy). A CD version of the manual is


For AM3440-CHA only
already included as standard equipment.
Loop-AM3440-UMB
Users Manual (optional, paper copy). A CD version of the manual is
For AM3440-CHB only
already included as standard equipment.
Loop-AM3440-UMC
Users Manual (optional, paper copy). A CD version of the manual is
For AM3440-CHC only
already included as standard equipment.
Power Cord(All power cord are RoHS compliant)
Loop-ACC-PC-USA
AC power cord for Taiwan/America
Loop-ACC-PC-EU
AC power cord for Europe
Loop-ACC-PC-UK
AC power cord for UK
Loop-ACC-PC-AUS
AC power cord for Australia
Loop-ACC-PC-CH
AC power cord for China
Power Adaptor(All power adaptor are RoHS compliant)
240 Watt, AC (3.6A, auto sensing) to DC (+48 Vdc, 5A) adaptor for USA
Loop-ACC-APA-240-G
240 Watt, AC (3.6A , auto sensing) to DC (+48 Vdc, 5A) adaptor for
Loop-ACC-APE-240-G
Europe
240 Watt, AC (3.6A, auto sensing) to DC (+48 Vdc, 5A) adaptor for UK
Loop-ACC-APU-240-G
Fan Tray

Loop-AM3440-FAN

Loop-AM3440-FAN-G

Fan tray

For AM3440-CHA only


Power supplied from rear of chassis.
If total power consumption of device
and cards is more than 60 Watts, an
additional fan tray is required. For
power consumption and fan tray plan,
please refer to AM3440-A Users
Manual.

FXO Box
Loop-AM3440-FXO BOX
External LCD
Loop-AM3440-LCD

Support FXO Interface Battery Feed


Loop-AM3440-LCD-G

External LCD and Keypad

Software
Loop-AM3440-ERING

ULSR-PDH Ring software


Note: ULSR ring only support E1 framed mode.
Loop-AM3440-TRING
ULSR-PDH Ring software
Note: ULSR ring only support T1 framed mode.
Conversion Cables(All conversion cables are RoHS compliant)
Loop-ACC-CAB-DB25MDB25/Male to eight BNC/Male cable; Length: 100 cm
100-8BNCM
Loop-ACC-CAB-DB25MDB25/Male to eight BNC/Female cable; Length: 100 cm
100-8BNCF
Loop-ACC-CAB-DB25MDB25/Male to eight BNC/Male cable; Length: 300 cm
300-8BNCM
Loop-ACC-CAB-DB25MDB25/Male to eight BNC/Female cable; Length: 300 cm
300-8BNCF
Loop-ACC-CAB-DB25MDB25/Male to four RJ48C/Male cable; Length: 100 cm
100-4RJ48M
Loop-ACC-CAB-DB25MDB25/Male to four RJ48C/Male cable; Length: 300 cm
300-4RJ48M
Loop-ACC-CAB-DB44MDSUB-44 pin/Male to two DSUB-25 pin/Female- one DSBU-9
100-2DB25F-1DB09F-DB
pin/Female (8P8C) plug, Length:100cm

only cover selected plug-in cards


only, contact your nearest Loop sales
representative for detail

Used with 4E1, M4E75, M4E120 and


FOM
Used with 4T1

Used in Loop-AM3440-M4E75
plug-in card
Used in Loop-AM3440-M4E75
plug-in card
Used in Loop-AM3440-M4E75
plug-in card
Used in Loop-AM3440-M4E75
plug-in card
Used in Loop-AM3440-M4E120
plug-in card
Used in Loop-AM3440-M4E120
plug-in card
Used in Loop-AM3440-8RS232-DB,
Loop-AM3440-8DBRA-DB plug-in
card
Used in Loop-AM3440-TS plug-in
card
Used in Loop-AM3440-6V35A and
Loop-AM3440-1V35 plug-in cards
Used in Loop-AM3440-6V36A and
Loop-AM3440-6R449A plug-in cards

Loop-ACC-CAB-DB44MDSUB-44 pin/Male to two DSUB-25 pin/Female- one DSBU-9


100-2DB25F-1DB09F-TS
pin/Female (8P8C) plug, Length:100cm
Loop-ACC-CAB-DB25MDSUB-25pin/Male to M34/Female V.35 Conversion cable
30-1M34F
Length: 30 cm
Loop-ACC-CAB-DB25M-30- DSUB-25pin/Male to DSUB-37/Female RS449 Conversion cable
1DB37F
Length: 30 cm
Y-Box(All Y-Box are RoHS compliant)
1 for 1 protection Y-Box with BNC connectors (4-E1)
Used with 4E1
Loop-VV-B-G
1 for 1 protection Y-Box with RJ48C connectors (16-E1)
Used with 4E1
Loop-VV-R-G
1 for 1 protection Y-Box with RJ48C connectors (16-T1)
Used with 4T1
Loop-VV-T-G
Blank Panels(All blank panels are RoHS compliant)
Blank Panel for Power Supply Slot (flat)
For AM3440-CHA only
30.000333.A00-G
Blank Panel for Power Supply Slot (flat)
For use in AM3440-CHB/CHC
30.001257.A00-G
Blank Panel for Controller Slot (flat)
For use in any AM3440 chassis
30.000349.A00-G
Blank Panel for mini Slot A-D (flat)
For use in AM3440-CHA/CHB/CHC
30.000335.A00-G
Blank Panel for Slot 1-12 (flat)
For use in AM3440-CHA/CHB/CHC
30.000331.A00-G
Blank Panel for Power Slot (u-shape)
For AM3440-CHA only
30.001028.A00-G
Blank Panel for Controller (u-shape)
For use in any AM3440 chassis
30.001029.A00-G
Blank Panel for mini Slot A-D (u-shape)
For use in AM3440-CHA/CHB/CHC
30.001030.A00-G
Blank Panel for Slot 1-12 (u-shape)
For use in AM3440-CHA/CHB/CHC
30.001027.A00-G
SFP Optical Modules
Please place your order using the 5-digit alphanumeric codes listed in the separate SFP Optical Module Brochure.
For 4E1 and 3E1cards
Where cc is used to select connector:
cc =
RJ48C connector
RJ
BNC connector
BNC

Description

Note

10

For FOM and 1FOMA card


Where opt is used to select optical module type (All optical modules are RoHS compliant):
opt =
Description
Note
Single optical module with dual uni-directional fiber, 1310 nm,
SAA
SC optical connector, 30 km - S1.1
Single optical module with dual uni-directional fiber, 1310 nm,
SBB
SC optical connector, 50 km - L1.1
Use dual fiber
Single optical module with dual uni-directional fiber, 1310 nm,
Units delivered ITU-T G.957
SCC
FC optical connector, 30 km - S1.1
application code
Single optical module with dual uni-directional fiber, 1550 nm,
SDD
SC optical connector, 20 km - S1.2
Single optical module with dual uni-directional fiber, 1550 nm,
SEE
SC optical connector, 100 km - L1.2
1310 nm from master to slave
Single optical module with single bi-directional fiber (master),
Order SSM to use with SSS
1310 nm transmit and 1550 receive, SC optical connector,
SSM
Use 1 fiber
30 km - S1.1/ S1.2
ITU-T G.957 application code
1550 nm from slave to master
Single optical module with single bi-directional fiber (slave),
Order SSS to use with SSM
1310 nm receive and 1550 transmit, SC optical connector,
SSS
Use 1 fiber
30 km - S1.1/ S1.2
ITU-T G.957 application code
Note: For other special optical modules, please contact your nearest Loop sales representative.
For Quad 2W/4W E&M card:
Where m is used to select QEM card signaling side (must select one):
m=
Description
B (carrier side) connects to A side.
B
A (exchange side) connects to B side. A side M lead to B side M lead, A side
A
E lead to B side E lead.

Note

Where n is used to select QEM card signaling type (must select one):
n=
Description
For voice transmission only.
O
Type I (Original) E&M Signaling Circuit
1
2

3
4
5

Note
Circuit Type doesnt matter.
M lead provides discharge for
the A side.
Type II Circuit. This design attempts to reduce ground noise by adding two Reduced ground noise. Ground
leads: SB (Signal to Battery) and SG (Signal to Ground)
current is eliminated at the cost
of two more wires per circuit.
Type III Circuit. The SG lead serves as a discharge for the M lead. Reduces Type III is rare because ground
delay caused by combination of (a) low current electronic detectors, and (b) currents on the E return would
long runs of the E and M leads.
cause noise
Type IV Circuit. Based on the Type 2 circuit. This E&M circuit provides
symmetry.
Type V Circuit. For applications where ground noise is not an issue.
Based on the Type 2 circuit.

For voice card(8-channel 2W/4W E&M, Quad 2W/4W E&M and QFXS/QFXO):
Where x is used to select all of voice card signaling bits. If this option is not required, omit the x field in the ordering code.
x=
Description
Note
Follows ETSI signaling bits
E
Follows ANSI signaling bits
A
Reverse for ON-HOOK and OFF-HOOK signaling bits exchange
R
Follows ANSI signaling bits and reverse bit
AR
8EM
Follows customers special bit or function assignment
S
Jumper selectable for all channels
Disable the function of the test button
S4
Forcing all ports to be OFF-HOOK when an alarm occurs
S5
Forcing all ports to be ON-HOOK when an alarm occurs
S6
Follows ETSI signaling bits
E
QEM
Follows ANSI signaling bits
A
Follows customer's special bits assignment
S
Follows ANSI signaling bits
QFXS/QFXO
A
A and S are for QFXS/QFXO
Follows customer's special bits assignment
S
Trunk condition OFF-HOOK
T
T, AT, ST are for QFXO only
AT

Follows ANSI signaling bits w/ trunk condition OFF-HOOK

11

ST

Follows customer's special bits assignment w/ trunk condition


OFF-HOOK

Note:
1. For S (customers special bit), please contact your nearest Loop sales representative.
2. If x is not selected from table above, the default setting for signaling bits is ETSI and for trunk condition is ON-HOOK.
For 12/24-channel FXS card:
Where sn is used to select special function. If this option is not required, omit the sn field in the ordering code.
sn =
Description
Note
FXS Loop Feed = -48 Vdc with 25 mA current limit; enable alarm tone; ring
sn = omit generator to automatic (power saver) mode
FXS Loop Feed = -48 Vdc with 35 mA current limit
S1
Remove alarm tone
S4
Double ring tone transmit
S5
Note: For sn (special function), please contact your nearest Loop sales representative.
Where pt is used to select the following functions.
pt=

Description

Note

PWR

complied with -48 Vdc(SD, S5, SDB), -125Vdc(SD125) and AC (SAB) power modules

PWRIE1613

complied with IEEE1613 standard, and with -48 Vdc(S5) power module

24

complied used with -24 Vdc(S524) power module

For AM3440-CHA only

For QFXS card:


Where pt is used to select the following functions.
pt=
Description
complied with -48 Vdc(SDB) and AC (SAB) power modules
PWR

Note

For Magneto Card:


Where x is used to select version type:
x=
Description

Note

16

16 Hz ring generator

20

20 Hz ring generator

25

25 Hz ring generator

50

50 Hz ring generator

20 Hz is the general setting for all


MAG cards. For special settings
(16,25,50), please specify your
need by filling in the x option.

For TDMoE:
SFP Optical/Electrical Module Plug-in option, please go to SFP Optical Module Brochure for detail.

12

Firmware Upgrade
Loop-AM3440-card- Firmware Upgrade and Warranty Renewal.
For available card types, please refer
FWUPGR
The Customer whose warranty has lapsed or desire to have a firmware upgrade to the table below for detail
can purchase this option.
information.
This will upgrade the firmware to the most current version and provide an
additional 12 months of support.
For Firmware Upgrade:
Where card is used to select card type:
card=
Description

Note

CCA

CPU card

M4E

Mini quad E1 card

4E1

Quad E1 card
Available for software version 3.02.01 or newer versions.

4T1

Quad T1 card
Available for software version 3.02.01 or newer versions.

RTA

RTA card
Available for software version 2.05.01 or newer versions.

RTB

RTB card
Available for software version 1.04.01 or newer versions.

3E1

3-port E1 card
Available for CHJ only and software version 1.02.01 or newer versions.

2GH

2-port G.SHDSL card


Available for software version 1.08.01 or newer versions.

4GH

4-port G.SHDSL card


Available for hardware version G and software version 4.01.01 or newer versions.

TDMoE

TDMoE card

12/24FXS

12/24 FXS card


Available for hardware version L and software version 3.01.01 or newer versions.

12/24FXO

12/24 FXO card


Available for hardware version G and software version 2.01.01 or newer versions.

8E&M

8-port E&M card


Available for software version 1.03.01 or newer versions.

8RS232

8 RS232 card
Available for software version 3.02.01 or newer versions.

8DBRA

8 Data Bridge A card

Conference

Conference card
Available for hardware version C and software version 1.02.01 or newer versions.

6V.36A

6-port V.36 card


Available for hardware version B and software version 2.03.01 or newer versions.

6V.35A

6-port V.35 card


Available for hardware version E and software version 2.03.01 or newer versions.

X.21/V.11

6-port X.21 card


Available for hardware version B and software version 2.03.01 or newer versions.

6EIA530/6RS449

6-port EIA530/RS449 card


Available for hardware version B and software version 2.03.01 or newer versions.

13

The list shown below is the discontinued chassis and plug in cards. For detail info, please contact your nearest Loop
sales representative.
Model
Description
Note
Loop-AM3440-CH
32 Mb/s cross-connect capacity backplane t without CPU, power AM3440-CH type Chassis
and plug-in cards
Loop-AM3440-6U
6-channel IDSL plug-in card
Loop-AM3440-10U
10-channel IDSL plug-in card
Loop-AM3440-3H
3-channel MDSL plug-in card (2Mb for 3-channel)
Loop-AM3440-3HA
3-channel MDSL plug-in card for
AM3440-A/B/C only
Loop-AM3440-3HAL
3-channel 6Mbits MDSL plug-in module with line power source AM3440-A only
Factory installed option available
with -48 Vdc powered chassis
only.
Loop-AM3440-5RS232
5-channel RS232 plug-in card with X.50 subrate plug-in module
Example 1:
Loop-AM3440-CHA, Loop-AM3440-CCA-E, Loop-AM3440-S5, Loop-AM3440-4E1-RJ, Loop-AM3440-8RS232
Loop-AM3440-FAN:
For 3440-A type chassis with a CPU card(E1 external clock), a single -48 Vdc 150W power module, 4-channel E1 interface with RJ48C
connectors, one 8RS232 plug-in module and fan tray.
Example 2:
Loop-AM3440-CHB, Loop-AM3440-CCA-E, Loop-AM3440-SDB, Loop-AM3440-M4E75, Loop-AM3440-8CD:
For 3440-B type chassis with a CPU card(E1 external clock), a single -48 Vdc 100W power module, one Mini Quad E1 interface with 75
ohm and one 8-channel G.703 interface at 64 Kbps data rate.
Example 3:
Loop-AM3440-CHC, Loop-AM3440-CCA-E, Loop-AM3440-SDB, Loop-AM3440-M4E120, Loop-AM3440-2GH:

For 3440-C type chassis with a CPU card(E1 external clock), a single -48 Vdc 100W power module, one Mini Quad
E1 interface with 120 ohm and one 2-channel G.SHDSL plug-in module (2 pair).

14

LOOP-AM3440 Access DCS-MUX Product Specifications


Network Line Interface - T1
Line Rate
1.544 Mbps 32ppm
Line Code
AMI or B8ZS
Input Signal
DSX-1 0 dB to -30 dB w/ALBO

Output Signal
Framing
Connector

DSX1w/0, -7.5, -15 dB LBO


D4/ESF (selectable)
RJ48C

Network Line Interface - E1


Line Rate
2.048 Mbps 50 ppm
Line Code
AMI or HDB3
Input Signal
ITU G.703
Output Signal
ITU G.703

Framing
Connector
Electrical
Jitter

ITU G.704
BNC/RJ48C
75 ohm Coax/120 ohm twisted pair
ITU G.823

Network Line Interface - Mini 4E1


Line Rate
2.048 Mbps 50 ppm
Line Code
AMI or HDB3
Input Signal
ITU G.703
Output Signal
ITU G.703

Framing
Connector
Electrical
Jitter

ITU G.704
DB25S
75 ohm Coax/120 ohm twisted pair
ITU G.823

Network Line Interface - 3E1


Line Rate
2.048 Mbps 50 ppm
Line Code
AMI or HDB3
Input Signal
ITU G.703
Output Signal
ITU G.703
Function
Support DS0-SNCP

Framing
Connector
Electrical
Jitter

ITU G.704
BNC/RJ48C
75 ohm Coax/120 ohm twisted pair
ITU G.823

Network Line Interface - 4E1


Line Rate
2.048 Mbps 50 ppm
Line Code
AMI or HDB3
Input Signal
ITU G.703
Output Signal
ITU G.703

Framing
Connector
Electrical
Jitter

ITU G.704
BNC/RJ48C
75 ohm Coax/120 ohm twisted pair
ITU G.823

Network Line Interface - 4T1


Line Rate
1.544 Mbps 32 ppm
Line Code
AMI or B8ZS
Input Signal
DSX-1 0 dB to -30 dB w/ALBO

Output Signal
Framing
Connector

DSX1w/0, -7.5, -15 dB LBO


D4/ESF (selectable)
RJ48C

ATM Frame Relay Network Line Interface (Discontinued)


Supporting Network Interworking (FRF.5) and service interworking (FRF.8).
Network Interface:
T1 ATM UNI
T1 Module:
FR (n x 64 Kbps, n=1 to 24)
E1 ATM UNI
E1 Module:
FR (n x 64 Kbps, n= 1 to 31)
Up to 31 logical FR channels can be concentrated/ de-concentrated to FR or ATM.
Service Ports:
n x 64 Kbps, n=1 to 24
T1/FT1 interface:
n x 64 Kbps, n= 1 to 31
E1/FE1 interface:
Support HDLC to FR
Support HDLC to ATM
Supporting FR to FR multiplexing.
Support up to 128 DLCIs for total of 31 FR interfaces.
Support up to 128 VCs.
Peak cell rate on DLCI basis.
Manufacturing disable/enable ATM scrambling for internal testing (E1 ATM only).
AAL0 and AAL5 are supported in the ATM adaptation layer.
Support VBR service.
ANSI and ITU FR management protocols are supported.
Flash memory software download through RS485.
Only the PVC type of ATM/FR service is supported.

15

Router Interface
Number of ports
Physical Interface
Connector
Routing protocol
Data Rates
Supporting Protocols
Router-A Interface
Number of ports
Physical Interface
Connector
Routing protocol
Supporting Protocols
Diagnostic
QoS
Router-B Interface
Number of ports
Physical Interface
Connector
Routing protocol
Supporting Protocols
Diagnostic
QoS

2 LAN ports, Max. 32 WAN ports


10 BaseT x 1, 10/100 BaseT x 1
RJ45
RIP-I, RIP-II
Channelized N x 64 Kbps up to T1/E1 capacity
TCP/IP, PPP, HDLC
2 LAN ports, Max. 64 WAN ports, Each WAN port has data rate n x 64K bps, 1 n 32 ( 4Mbps for total
of all 64 WAN ports
10/100 BaseT x 2
RJ45
RIP-I, RIP-II, OSPF, Static
PPP (IPCP/BCP), MLPPP, HDLC, Frame Relay, and Cisco compatible HDLC, NAT/NAPT, DHCP
Ping, Trace route
Rate limit
8 LAN ports, Max. 64 WAN ports. Each WAN port has data rate n x 64K bps, 1 n 32 ( 8Mbps for total
of all 64 WAN ports
10/100 BaseT x 8
RJ45
RIP-I, RIP-II, OSPF, Static
PPP (IPCP/BCP), MLPPP, HDLC, Frame Relay, and Cisco compatible HDLC, NAT/NAPT, DHCP
Ping, Trace route
Rate limit

Terminal Server Interface


Connector
Ports
Data Rate
Layer 2 Protocol of RS232 Async
Layer 2 Protocol of RS232 Sync
Terminal Server Function
Router Function

One DB-44 conversion cable to one DB-9 and two DB-25 connectors
One Async RS232 port, two Async/Sync RS232 ports.
The two Async/Sync ports can be configured independently as Asynchronous or
Synchronous.
Async: 1.2kbps, 2.4kbps, 4.8kbps, 9.6kbps, 19.2kbps, 38.4kbps
Sync: 64 kbps
raw data
PPP
Supports Telnet
RIP-I, RIP-II, Static Route

Fiber Optical Interface (FOM, 1FOM-A)


Source

MLM Laser

Line Code

Scrambled NRZ

Wavelength

1310 50 nm, 1550 40 nm

Detector Type

PIN-FET

Protection

Optional 1+1 APS

50 Km reach
NOTE: Longer or shorter, 15 to 120Km, on special order.

Optical Module
Fiber Direction
Wavelength (nm)
SAA
Dual uni-directional
1310
SBB
Dual uni-directional
1310
SCC
Dual uni-directional
1310
SDD
Dual uni-directional
1550
SEE
Dual uni-directional
1550
SSM
Single bi-directional (master)
1310/1550
SSS
Single bi-directional (slave)
1550/1310
NOTE: Other fiber optical options available on special order
G.SHDSL Line Interface
Number of ports
Line Rate for 4-channel G.shdsl
Line Rate for 2-channel G.shdsl
Line Code
Connector
Electrical
Sealing current
Clock Source
Diagnostic Test

Connector
SC (Subscriber Connector)
SC (Subscriber Connector)
FC (Fiber Connector)
SC (Subscriber Connector)
SC (Subscriber Connector)
SC (Subscriber Connector)
SC (Subscriber Connector)

2 or 4
n x 64Kbps (n= 3 to 31)
n x 64Kbps (n= 3 to 15)
16-TCPAM, full duplex with adaptive echo cancellation
RJ45
Unconditioned 19-26 AWG twisted pair
Max. 20 MA source current
From System, Line
G.SHDSL Loopback: To-LINE, To-bus
BERT: QRSS

16

Distance (km)
30
50
30
20
100
30
30

DTE Interface (X.21)


Data Port
Up to six 6-port DTE X.21 card; 1-port DTE X.21 card
Data Rate
56 or 64 Kbps, n = 1 to 32
Connector
DB15S
DTE Interface (V.35)
Data Port
Up to six 6-port DTE V.35 card; ; 1-port V.35 card
Data Rate
56 or 64 Kbps, n = 1 to 32
Connector
DB25S (optional conversion cable DB25S to M34 connector)
DTE Interface (V.36)
Data Port
Up to six 6-port DTE V.36 card
Data Rate
56 or 64 Kbps, n = 1 to 32
Connector
DB25S (optional conversion cable DB25S to DB37 connector)
DTE Interface (EIA530/RS449)
Data Port
Up to six 6-port EIA530 DTE card; 1-port EIA530 card
Data Rate
56 or 64 Kbps, n = 1 to 32
Connector
DB25S (optional conversion cable DB25S male to DB37 female connector for RS449)
DTE Interface (RS232/V.24)
Data Port
1-port RE232 card
Data Rate
56 or 64 Kbps *n, n=1 - 2
Mapping
Any sequential time slots

DTE Interface (RS232-X.50 mux. 8-port)


Data Port
Up to twelve 8-port RS232 cards
MUX
Maximum 5 subrate port per 64K bps
Data Rate
Mux mode
Asynchronous
Independent mode
Mux mode
Synchronous
Independent mode
Card Type
Eight RJ48

Port Number
1
2
Async/
Async/
Sync Note 1
Sync Note 1

3
Async

0.6K, 1.2K, 2.4K, 4.8K, 9.6K


0.6K, 1.2K, 2.4K, 4.8K, 9.6K, 19.2K, 38.4K
0.6K, 1.2K, 2.4K, 4.8K, 9.6K
0.6K, 1.2K, 2.4K, 4.8K, 9.6K, 19.2K, 38.4K, 48K, 64K
4
Async/
Sync Note 1

5
Async/
Sync Note 1

6
Async

7
Async

8
Async

Two DB44 + Two RJ48 Async/Sync Async/Sync Async


Async/Sync Async/Sync Async
Async
Async
Connector
Eight RJ48 (port 1 to port 8)
DB44 (port1,port2,port3), DB44 (port4,port5,port6), RJ48 (port7) and RJ48(port8)
Conversion Cable
A three-into-one conversion cable adapts the DB44 connector to 3 connecters (one DB9S and two
DB25S)
Electrical
RS232 Interface, DCE
Note 1: Sync- with rate up to 19.2 Kbps achieved by oversampling at 64 Kbps

DTE Interface (Data Bridge Card)


Data Port
Up to twelve 8-port data bridge card (each card supports up to 120 DS0 for data bridge)
Feature
20 end points per multi-drop circuit to into a logical ended 56K or 64K channel
Per port supports bridge function to N remote Trib. Site (N=1~20)
Data Rate
Asynchronous
Support to receive 1200 to 19200 bps asynchronous data via oversampling channel
Bridge function
one port with one DS-0 to many (Maximum is 20 for remote Tributary data box )
20 drops for each DS0 to remote Tributary data box and 8 ports RS232 shared the 128 channels.

17

8UDTEA (RS232/RS422/RS485) universial data Interface


Data Port
8 port UDTE card
ASYNC Data Rate
200,300, 600, 1200, 2400, 4800, 9600, 19.2K, 38.4K, 57.6K, 115.2K, 128K bps by
oversampling
Connector
RJ48C
Interface
DCE only
Flow Control (RS232 only)
Hardware (RTS and DTR), none
Loopback function
DTE to DTE loopback
DTE to Line loopback
1 Port OCU-DP Interface Card
Ports
Operating Modes
Dedicated Rates
OCU DP Operation
Local Loop Signal
Transmit Amplitude
Transmit Source Impedance
Receive Input Impedance
Receiver Sensitivity/ Dynamic
Range
Physical Interface
Network to Loop Test Codes
Loop to Network Test Codes
8 Port OCU-DP Interface Card
Ports
Line Status Indicator
Network Connector
Electrical Network Connection
Transmit Source Impedance
Receive Input Imdednace
Receiver Sensitivity
Dynamic Range
Pulse Amplitude

Sealing Current
Operating Modes
Circuit Rates
Encoding and decoding rules
Maintenance control

Fault and Performance


Enviroment
Specification Standard

1 Ports card
4-wire DDS or switched 56
SYNC: 2.4, 4.8, 9.6, 19.2, 56 and 64k clear channel
Conforms with AT&T Pub 41458
Conforms with AT&T 62310 and ANSI T1.410
Bipolar Return to zero, 50% duty cycle
+/- 1.5 V (+/- 10%) peak, all rates except 9.6k
+/- 0.75 V (+/- 10%) peak at 9.6k
135 Ohms +/- 20%
135 Ohms +/- 20%
0 to 43 dB loop loss at 72K & 56K
0 to 34 all other rates
4-wire loop interface
RJ45 modular connector
Zero code suppression, Idle, out of service, UMC, MOS, TC, ABS, channel loopback, OCU
and DSU loop-back, latch loop-back (TIP, LSC, LBE, FEV)
Zero code suppression, Idle
8 Ports for each card
Per Port 1 dual color LED; Red for LOS, Green for SYNC
RJ48S
Tip/Ring and Tip1/Ring1
135 Ohms +/-20%
135 Ohms +/-20%
0 to 43 dB loop loss at 72K & 56K
0 to 34 all other rates Automatic line equalization
+/- 1.5V (+/-10%) peak, all rates except 9.6K
+/-0.75 (+/-10%) peak at 9.6K
Bipolar Return to zero, 50 duty cycle
Typically 16mA DC
4-wire DDS
Switched 56 support is optional
SYNC: 2.4, 4.8, 9.6, 19.2, 56, 72 kbps (64k) clear channel
Conforms with AT&T Pub 41458
Use bipolar violation to indicate control information: Idle, out of service, Zero
Subsitution using unframed loops
DSU Non-latching loop-back code (for 2.4, 4.8, 9.6, 19.2, 56k circuit rate)
DSU Latching loop-back (TIP, LSC, LBE, FEV) code (for 72k circuit rate)
Machine maintenance OCU/DP card operation:
Payload loopback
OCU loopback
Local loopback
Bi-directional loopback
V.54 remote loopback code
Custom defined remote loopback code
BERT test support all ones, all zeros, 2047,511,63 pattern.
LOS, OOS, ES, SES and UAS alarm.
Current, last 96 registry and 7 days performance storage.
Operating: 0-50C
Storage: -25-75C
Humidity: Up to 90% RH non-condensing
ANSI T1.410; AT&T Pub 62319, AT&T Pub 62310, ITU-T V.54

18

Co-directional Interface
Interface
ITU G.703 64 Kbps co-directional interface
Connector
120ohm, RJ48
Line Distance
Up to 500 meters
Loopack
DTE Payload Loopback, Local Loopback
C37.94 Interface
Source
Wavelength
Connector
Optical Budget

Dry Contact Interface


Inputs 8-channel
Connector
Internal Resistance
Activation Current
Deactivation Current
Allowable Current

LED
820nm 2Km reach
ST
50 Mircon core/9.6 db
62.5 Mircon core/ 15db

2-port per card, 4-pair per port


RJ45
1K
3 ma
1.5 ma
4 ma

Dry Contact Type B Interface


Inputs 8-channel
2-port per card, 4-pair per port
Connector
RJ45
Internal Resistance
100 K
Activation Current
3 ma
Deactivation Current
1.5 ma
Allowable Current
4 ma

Outputs 8-channel
Connector
Initial Insulation Resistance
Max. Current
Max. Voltage

8-pair per card


Screw type
Min. 100M ohm (at 500 Vdc)
5A
100 Vdc, 250 Vac

Outputs 8-channel
Connector
Initial Insulation Resistance
Max. Current
Max. Voltage

8-pair per card


Screw type
Min. 1000M ohm (at 500 Vdc)
2A
220 Vdc, 250 Vac

Voice Card (Q2EM, Q4EM)


Connector
One 44-pin connector, adapter cable included for 4 RJ45 connectors.
Power
110-220Vac, 24Vdc, 48Vdc
Alarm Conditioning
CGA busy after 2.5 seconds of LOS, LOF
Encoding
A-law or -law, user selectable as a group
Impedance
Balanced 600 or 900
Longitudinal Rejection
55 dB
Longitudinal Max
2.5 volts peak AC
Longitudinal Balance
> 63dB
Gain Adjustment
0, -3, -6 or +7 dB for transmit (D/A) gain
(all port settings)
0, -3, -6 or +10 dB for receive (A/D) gain
Signal/Distortion
> 46dB with 1004 Hz, 0dBm input
Frequency Response
+0.5 to -0.9 dB from 300 to 3400 Hz
Idle Channel Noise
< 20 dBrnC0
Signaling
Type 1, Type 2, Type 3, Type 4, Type 5, and also TO (Transmit Only)
Modems
Full compatibility with V.90 modems
E Lead Sensor Current
0.25 mA (minimum)
Signaling Bit Setting
Jump Selectable
Operational Temp.
0C to +50C
Relative Humidity
0% to 95%
z
All in-band signaling tones are carried transparently by the digitizing process.
z
Customer is responsible for in-band signaling compatibility between a telephone and a switch, or between a PBX and a
switch.

19

Voice Card (8EM)


Connector
Alarm Conditioning
Encoding
Impedance
Gain Adjustment (Per-port setting)

Eight RJ45
CGA busy after 2.5 seconds of LOS, LOF
A-law or -law, user selectable together for all
Balanced 600 or 900 ohms
-16 to +7 dB / 0.1dB step for transmit (D/A) gain
-16 to +14 dB / 0.1dB step for receive (A/D) gain
I/O Power Range
A/D Analog input level: -66 dBm (0.00039 Vrms) ~ + 3 dBm (1.09 Vrms)
D/A Analog output level: -66 dBm (0.00039 Vrms) ~ + 4 dBm (1.22 Vrms)
Gain Variation
0.5 dB at 0 dBm0 input
Frequency Response
0.5 dB at 0 dBm0 input
Longitudinal Conversion Loss
> 46dB
Total Distortion
35 dB at 0 dBm0 input
Idle Noise
-65 dBm0p
Carrier Connection
Side A ( exchange side) and Side B (carrier side) setup by side switch
Idle Channel Noise
Max. 65 dBm0p
Wire Mode
2 wire and 4 wire (programmable)
Signaling
Type 1, Type 2, Type 3, Type 4, and Type 5, Transmit only (programmable)
Modems
Full compatibility with V.90 modems
z
All in-band signaling tones are carried transparently by the digitizing process.
z
Customer is responsible for in-band signaling compatibility between a telephone and a switch, or between a PBX and a
switch.
Voice Card 12 MAG (Magneto)
Connector
Alarm Conditioning
Encoding
Impedance
Longitudinal Conversion Loss
Gain Adjustment
Signal/ Distortion
Frequency Response
Idle Channel Noise
Signaling
Minimum Detectable Ringing Voltage
Crank Detectable Across
Crank Detected time
Ringing Generation

Ring duration

RJ11 x 12
CGA busy after 2.5 seconds of LOS, LOF
A-law or -law, user selectable together for all
Balanced 600 or 900 ohms (for magneto telephone impedance )
> 46dB
-21 to +10 dB / 0.1dB step transmit & receive
> 25dB with 1004 Hz, 0dBm input
- 0.25 to -1 dB from 300 to 3400 Hz, coincide with ITU-T G.712
Max. 65 dBm0p
16 Vrms
L1 & L2 Mode (Tip and Ring), L1 & GND Mode(Tip and GND)
Valid carnk: more than 250 ms
Invalid crank: less than 160 ms
Voltage: 76 Vrms (sine wave)
Frequency: 20Hz (with optional choices of 16, 25, 50 Hz)
Two optional modules are available for your choice:
1. 12MAG
Normal operation: Ring duration depends on cranking time
PLAR ON operation: when FXS pone off-hooked, the ring duration of the
far-end magneto phone could be 0.5, 1.0, 2.0 or 4.0 sec

2. 12MAG-A
Normal operation: Crank the phone for one time, and the ring duration of the
far-end phone could be 0.7, 1.5 or 2.0 sec
PLAR ON operation: when FXS phone off-hooked, the ring duration of the
far-end magneto phone could be 0.7, 1.5 or 3.0 sec
Ringing Send Across
L1 & L2 Mode (Tip and Ring), L1 & GND Mode(Tip and GND)
Signaling
Turn Magneto Phone crank (Ringing across Tip and Ring or Tip and Ground)
Signaling Bit A,B,C,D
Programable
y
Signaling is carried transparently by the digitizing process.
y
Use Magneto card default setting for communications between magneto telephones
y
Use Magneto card PLAR mode setting for communications between a magneto telephone and a regular telephone

20

Conference Card
RS232 Interface
Data Port
ASYNC Data Rate
SYNC
Connector
FXS Voice Interface
Connector
Encoding
Longitudinal Conversion Loss
Cross Talk Measure
Gain Adjustment
Signal/ Distortion
Idle Channel Noise
Loop Resistance
FXS Loop Feed
FXS Ringing

Signaling
E&M Voice Interface
Connector
Encoding
Impedance
Longitudinal Conversion Loss
Gain Adjustment
Signal/Distortion
Idle Channel Noise
Carrier Connection
Phone line power+12V
Operation mode
Wire Mode
Signaling Type
EM Ringing

2-ports per card


300, 600, 1.2K, 2.4K, 4.8K, 9.6K, 19.2K
not supported
Two DB9, DCE, female
Two RJ11
G.723
> 46dB
Max -70dBm0
transmit (D/A) gain 0, +6dB
receive (A/D) gain +6, 0, -6dB
> 25dB with 1004 Hz, 0dBm input
Max. 65 dBm0p
Max 1800 ohm
-48 Vdc with 25mA current limit per port
2 REN
20Hz
76 Vrms
2 sec on / 4 sec off for 1 min, or 1 sec on / 2 sec off for 30 sec (programmable)
Loop Start, DTMF
Two RJ45
G.723
Balanced 600 ohms
> 46dB
transmit (D/A) gain 0, +6dB
receive (A/D) gain +6, 0, -6dB
> 25dB with 1004 Hz, 0dBm input
Max. 65 dBm0p
Side A = exchange side, Side B = carrier side (Jumper selectable)
Type P (Jumper enable)
Master, standard (Jumper selectable)
4 wire
Type 1, Type 4, and Type 5 (Jumper selectable)
Single rainging for 5 sec only
2 sec on / 4 sec off for 1 min, or 1 sec on / 2 sec off for 30 sec (programmable)

21

Voice Card (QFXS, QFXO)


Quad FXS voice card (4 FXS per plug-in)
Quad FXO voice card (4 FXO per plug-in)
Connector
QFXS: 1, 2, 3, or 4 FXS per RJ11 connector, QFXO: 1, 2, 3, or 4 FXO per RJ11 connector
Power for QFXS
110-220Vac, -24Vdc or 48Vdc
Power for QFXO
110-220Vac, -24Vdc, and 48Vdc
Alarm Conditioning
CGA busy after 2.5 seconds of LOS, LOF
Encoding
A-law or -law, user selectable together for all
AC impedance
Balanced 600 or 900 ohms (selectable together for all)
Longitudinal Rejection
55 dB
Loss Adjustment
0, 3, 6, or 9 dB transmit & receive
Signal/ Distortion
> 46dB with 1004 Hz, 0dBm input
Frequency Response
- 0.25 to -1 dB from 300 to 3400 Hz
FXS Loop Feed
-48Vdc or -24Vdc with 25mA current limit per port
Jumper Selectable: 25mA, 30mA, 35mA
FXO
Ringing REN
0.5B (AC)
Detectable Ringing
25 Vrms
Loop Resistance
1800
DC impedance (ON-HOOK)
> 1M
DC impedance(OFF-HOOK) 235 @ 25mA feed
90 @ 100mA feed
FXS Ringing
Support 2 REN per port (1 REN = 6930 + 8 F)
20 Hz, other frequencies: 16.7Hz, 25 Hz, 50Hz (Jump selectable)
78 Vrms (sine wave) (45 Vrms to 86 Vrms wide range by Resistor selectable)
2 sec on 4 sec off, or 1 sec on 2 sec off optional for PLAR
Metering Pulse
12KHz/ 16KHz
y
Power: 10dBm
y
Sensitivity: -27dBm (-21dBm to -45dBm by Resistor selectable)
Signaling
Loop Start, GND-Start, Metering Pulse (12KHz, 16KHz), DTMF, Dialing Pulse, PLAR,
Battery Reverse (supports Line Reverse Signaling for Billing)
z
All in-band signaling tones are carried transparently by the digitizing process.
z
Customer is responsible for in-band signaling compatibility between a telephone and a switch, or between a PBX and a switch.
z
-24Vdc power is for FXS PCB version C and up
Voice Card (12FXS, 12FXO, 24FXS, 24FXO)
12 FXS/FXO Connector
Twelve RJ11
24 FXS/FXO Connector
One RJ21X Female
Alarm Conditioning
CGA busy after 2.5 seconds of LOS, LOF
Encoding
A-law or -law, user selectable together for all
AC Impedance
Balanced 600 or 900 ohms (selectable together for all)
Longitudinal Conversion Loss
> 46dB
Cross talk measure
Max -70dBm0
Gain Adjustment
-21 to +10 dB / 0.1dB step transmit & receive
Signal/ Distortion
> 25dB with 1004 Hz, 0dBm input
Frequency Response
- 0.25 to -1 dB from 300 to 3400 Hz, coincide with ITU-T G.712
Idle Channel Noise
Max. 65 dBm0p
Variation of Gain
0.5dB
FXO
Ringing REN
0.5B (AC)
Detectable Ringing
25 Vrms
Loop Resistance
1800
DC Impedance (ON-HOOK)
> 1M
DC Impedance (OFF-HOOK)
235 @ 25mA feed
90 @ 100mA feed
FXS Loop Feed
-48Vdc or -24Vdc with 25mA current limit per port
Jumper Selectable: 25mA, 30mA, 35mA
FXS signalling
Normal / Automatic Ring down
FXS Ringing
1 REN at 5K meters per port
16.7Hz, 20Hz, 25Hz, 50Hz, user selectable for all ports
38 to 85 Vrms (sine wave), 76 Vrms for default Ring Voltage
2 sec on 4 sec off, or 1 sec on 2 sec off optional for PLAR
Signaling
Loop Start, DTMF, pulse, PLAR, Battery Reverse
Optional Signaling (for special
Ground Start, Metering pulse (12 KHz, 16 KHz), and P( in PLAR mode, PLAR signalling bits
order)
are programmable.
Signaling Bit A,B,C,D
Programable bit
z
All in-band signaling tones are carried transparently by the digitizing process.
z
Customer is responsible for in-band signaling compatibility between a telephone and a switch, or between a PBX and a switch.
z
-24Vdc power is for FXS PCB version L and up

22

Phone Line Monitor Card


Connector
Alarm Conditioning
Encoding
Impedance
Total Distortion
Frequency Response

Four RJ11 connectors


CGA busy after 2.5 seconds of LOS, LOF
A-law or -law, user selectable as a group
Balanced 15K Ohm
> 35dB with 1004 Hz, 0dBm input
0 ~ -0.5 dB from 300 to 2000 Hz
-0.5 dB ~ -2 dB from 2000 to 3300 Hz
Idle Channel Noise
> -60 dBm0
Gain Adjustment
0, -3, -6 or +7 dB for PLM (B) transmit gain (D/A)
(All Port Setting)
0, -3, -6 or +3dB for PLM (A) receive gain (A/D)
Off-Hook Detect Level
< -6V Line to GND
Operational Temp.
0C to 50C
Relative Humidity
0% to 95%
Power
110 ~ 220 VAC, -48 Vdc
All in-band signaling tones are carried transparently by the digitizing process.
Signaling Bits
Normal

AB Bit Invert

Tx
Status

Rx

Line On Hook

Line Off Hook

Tx

Rx

PLM (A) to Line

Battery (-48V)

Battery (-6V)

PLM (B) to Monitor

23

TDMoE
Combo Gigabit Ethernet(GbE) Interface
Number of Ports
2
Speed
10/100/1000M bps
Connector
RJ45 for twisted pair GbE, LC for optical GbE, auto detection
Gigabit Ethernet(GbE) Interface
Number of Port
2
Speed
10/100/1000 BaseT
Connector
RJ45
Ethernet Function
Basic Features
MDI/MDIX for 10/100/1000M BaseT auto-sensing
Ping function contained ARP
Per port, programmable MAC hardware address learn limiting (max. MAC table 8192 (8k) entry)
Packet Delay Variation:
- Unframed T1: Up to 340 ms
- Framed T1: Up to 256 ms
- E1:up to 256 ms
- Framed T1 with CAS: Up to 192 ms
Packet Transparency
Packet transparency support for all types of packet types including IEEE 802.1q VLAN and 802.1ad
(Q-in-Q)
QoS
User configurable 802.1p CoS, ToS in out going IP frame
Traffic Control
Ingress packet Rate limiting buckets per port for Ethernet port
Supporting Rate-based and Priority-based rate limiting for LAN port
Granularity:

From 64 Kbps to 1 Mbps in increments of 64 Kbps

From 1 Mbps to 100 Mbps in increments of 1 Mbps

From 100 Mbps to 1000 Mbps in increments of 10Mbps

Link Aggregation

Pause frame issued when the traffic exceeding the limited rate before packet dropped following
IEEE802.3X
WAN support link aggregation

Jitter & Wander


PPM: per G.823 Traffic
PPB: per G.823 Synchronous
Standard Compliance
IETF
IEEE

TDMoIP (RFC5087), SAToP (RFC4553), CESoPSN (RFC5086)


802.1q, 802.1p, 802.1d, 802.3, 802.3u, 802.3x, 802.3z, 802.1s, 802.1w, 802.1AX

Clock Source
Internal, E1/T1 Line, External
Alarm Relay
Max. Current: 1A for 24VDC, 0.625A for 48VDC
Fuse alarm, performance alarm
System Configuration Parameters
Active Configuration, Stored Configuration, and Default Configuration (Stored in Non-volatile Memory)
Management
Console
Ethernet
Inband Management
Ethernet LCD
Performance Monitor
Performance Registers
Separate Registers
Performance Reports
Alarm Queue
Threshold

Electrical: RS232; Connector: DB9, female


User Interface: Menu driven VT-100
1 port, Connector: RJ45
10/100 Base T, SNMPv1, v3/Telnet/SSH
Inband 64 Kbps, support HDLC/PPP
Optional
Last 24 hours performance in 15 minute intervals and last 7 days in 24 hour summaries
Network, user, and remote site
Reports include E1 Bursty Errored Second, Severe Errored Second, Degraded Minutes. Also
available in Statistics (%)
To record the latest alarm type, location, and date & time
Bursty Seconds, Severely Errored Second, Degraded Minutes

Diagnostics

Loopback
Test Pattern

E1/T1 interface (Line Loopback, Payload Loopback, Local Loopback), DTE Loopback
(DTE-to-DTE, DTE to Line)
For Controller: 220-1, 215-1, 211-1, 29-1, and 4-bye user define pattern

24

Front Panel
Controller LED Indicators

Power, ACTIVE, ALARM


A, B, C, D slots: SYNC/TEST, LOF, BPV, RAI/AIS

Physical /Electrical
Dimensions
Power

Temperature
Humidity
Mounting
Line Power
Supply
Power
Consumption

AM3440-A
432.4 x 220 x 223.5 mm (WHD)
Single/ Dual -48 Vdc: -36 to -75 Vdc,
100 Watts max.
Single/ Dual -48 Vdc: -36 to -75 Vdc,
150 Watts max.
Single/ Dual -24 Vdc: -18 to -36 Vdc,
150 Watts max
Single/ Dual -125 Vdc: -40 to -150 Vdc,
100 Watts max
0-55C
0-95%RH (non-condensing)
Desk-top stackable, 19 /23 rack
mountable
Available only with DC power for
G.SHDSL card only
Max 110 Watts

Certification
AM3440-A
EN55022 Class A, EN50024, FCC Part 15
Class A, FCC Part 68, CS-03, IEC60950,
UL60950, IEC 61850-3, IEEE 1613

AM3440-B
438 x 110 x 224 mm (WHD)
Single/ Dual -48 Vdc: -36 to -75 Vdc,
100 Watts max.
Single AC: 100 to 240 Vac, 50/60 Hz

AM3440-C
438 x 132 x 224 mm (WHD)
Single/ Dual -48 Vdc: -36 to -75 Vdc,
100 Watts max.
Single AC: 100 to 240 Vac, 50/60 Hz

0-55C
0-95%RH (non-condensing)
Desk-top stackable, 19 /23 rack
mountable
N/A

0-55C
0-95%RH (non-condensing)
Desk-top stackable, 19 /23 rack
mountable
N/A

Max 45 Watts

Max 57 Watts

AM3440-B
EN55022 Class A, EN50024, EN300 386,
FCC Part 15 Class A, FCC Part 68, CS-03,
IEC60950-1, EN60950-1

AM3440-C
EN55022 Class A, EN50024, EN300 386,
FCC Part 15 Class A, IEC60950-1,
CS-03, EN60950-1

Note for IEC 61850-3 and IEEE1613:


(1) The certification only applies to AM3440-A, -48Vdc(150W) power module
(2) The magneto card does not support IEC 61850-3 and IEEE 1613
(3) Use shielding cable with the following modules:
Console port of CCA

SNMP of CCA

Single RS232

Single X.21

Single EIA530

Single V.35

Terminal Server

Router

Router-A

ATM/FR E1/T1

RS232-X.50

DTE of Conference

Input Port of Dry Contact

Input Port of Dry Contact B

RS232 X.50-8

V.35

V.36/RS449/EIA530

X.21

Compliance
ITU G.703, G.704, G.706, G.732, G.736, G.823, G.826, G.711, G.712, G.775, O.151, V.11, V.28, V.54
IETF SNMP v.3 (RFC2571~2575)
Specifications for Loop-VV Y-BOX
LINE
Connector
Port Number
Protection

Mechanical
Height
Width
Depth

BNC or RJ48C
For Y-BOX with BNC connectors: 4 line ports
For Y-BOX with RJ48C connectors: 16 line ports
For Y-BOX with BNC connectors: support 2 Quad E1 plug-in card, 4 active E1, 4 standby E1
For Y-BOX with RJ48C connectors: support 8 Quad E1 plug-in cards, 16 active E1, 16 standby E1
For Y-BOX with RJ48C connectors: support 8 Quad T1 plug-in cards, 16 active T1, 16 standby T1
44.5 mm/ 1.75 in
432 mm/ 17 in
100 mm/ 3.9 in

25

Application Illustration:

26

CTRL 2
CTRL 1
Plug - in(2)
Plug- in(1)

Mini Plug- in (C)


Mini Plug- in (B)
Mini Plug- in (A)

Mini Plug - in(D)

Plug -in (3)

1 - channel E1
1 - channel T1
Mini Quad E1
1 - channel E1 ATM Frame Relay (D)
1 - channel T1 ATM Frame Relay (D)
32 WAN port Router

6 - channel X.21/ V.11


6 - channel V.35
6 - channel V. 36
6 - channel EIA530/RS449
24 - channel FXS
24 - channel FXO

3 - channel E1
4 - channel E1

Note

64 WAN port Router


Fiber Optical Interface

4 - channel T1

3 - channel Terminal Server

2 - channel G.SHDSL w /o line power

Quad 2 W/4 W E&M

4 - channel G.SHDSL w /o line power


8 - channel G.703 64 Kbps

QFXS / QFXO

8 - channel Dry Contact I/O


8 - channel Dry Contact I/O Type B
8-

channel 2 W/4 W E&M

1- channel DTE (1X.21, 1V.35,


1RS232, or 1EIA530)
1- channel OCU-DP

Phone Line Moitor Card

12- channel FXS


12- channel FXO
12- channel Magneto
1-

channel C37. 94

4 - channel C37 . 94
8 - channel RS232 with X.50 subrate
8 - LAN- port / 64- WAN - port Router -B
Conference card
TDMoE
8- Data Bridge
Note: Not Applicable to DS0 SNCP function
(D) = Discontinued

1FOMA
8UDTEA

27

CTRL 2
CTRL 1
Plug - in(3)
Plug - in(2)
Plug - in(1)

Mini Plug-in (C)


Mini Plug-in (B)
Mini Plug-in (A)

Mini Plug-in(D)

Plug -in (5)


Plug -in (4)

1 - channel E1
1 - channel T1
Mini Quad E1
1 - channel E1 ATM Frame Relay (D)
1 - channel T1 ATM Frame Relay (D)
32 WAN port Router

6 - channel X.21/ V.11


6 - channel V.35
6 - channel V. 36
6 - channel EIA530/RS449
24- channel FXS
24 - channel FXO

3 - channel E1 Note
4 - channel E1

64 WAN port Router

4 - channel T1

3 - channel Terminal Server

Fiber Optical Interface

2 - channel G.SHDSL w /o line power

Quad 2 W/4 W E&M

4 - channel G.SHDSL w /o line power


8 - channel G.703 64 Kbps

QFXS / QFXO

8 - channel Dry Contact I/O


8 - channel Dry Contact I/O type B
8-

channel 2 W/4 W E&M

1 - channel DTE
(1X.21, 1V.35, 1RS232, or 1EIA530)
1- channel OCU-DP

Phone Line Moitor Card

12- channel FXS


12- channel FXO
12- channel Magneto
1-

channel C37. 94

4 - channel C37 . 94
8 - channel RS232 with X.50 subrate
8 - LAN- port / 64- WAN - port Router -B
Conference card
TDMoE
8- Data Bridge

Note : Only CHCJ Unit applicable to


DS0 SNCP function
(D) = Discontinued

1FOMA
8UDTEA

28

ULSR Ring Application

E1
HDLC

Router

Port A
4E1

TS31
TS1-30

TS1-30

Management PC

MASTER
Port B
4E1

TS1-2
TS3-4

Port A
4E1

TS30
TS5-31

TS5-6
TS7-8
TS29

TS30

Clk: A/B

HDLC

Port A
4E1

HDLC

TS29

SLAVE #4

Port A
4E1

TS27
TS15-16
TS13-14

Port B
4E1

Port C
4E1

TS28

HDLC

Port D
4E1

TS1-31

Clk: A/B

Clk: A/B

SLAVE #2
Port D
4E1

Port D
4E1

TS27

TS1-12
TS17-31

Port B
4E1

TS1-4
TS1-31
TS9-31

TS1-31

TS1-31

Clk: A/B

HDLC

Port C
4E1

Port B
4E1

TS1-31

SLAVE #1
Port D
4E1

TS1-31

Inband

Inband Mamnagement is set up by


assigning1 DS0 (64K) for inband
management purposes on the TSl
timeslot map of each AM 3440-A unit.

Port C
4E1

TS1-31

Clk: A/Internal

Port C
4E1

HDLC

Port A
4E1

Port B
4E1

TS1-8
TS13-31
TS28
TS11-12
TS9-10

SLAVE #3
Port C
4E1

Note: ULSR ring does not suport E1 unframed mode. Users must use E1 framed mode to set up a ULSR ring.

LoopTelecom.com

LOOP TELECOMMUNICATION INTERNATIONAL, INC.


ISO 9001/ISO 14001

Worldwide

Taipei, Taiwan

North America

Tianjin China

8F, No. 8, Hsin Ann Road,


Science-Based Industrial Park
Hsinchu, Taiwan 30078
Tel:+886-3-578-7696
Fax:+886-3-564-6272
www.LoopTelecom.com
[email protected]

6F, No. 36, Alley 38, Lane 358,


Rueiguang Road,
Neihu, Taiwan 11492
Tel:+886-2-2659-0399
Fax:+886-2-2659-2325
[email protected]

8 Carrick Road
Palm Beach Gardens
Florida 33418, U.S.A.
Tel:+1-561-627-7947
Fax:+1-561-627-6615
[email protected]

No. 240 Baidi Road


Nankai District
Tianjin 300192 China
Tel:+86-22-8789-4027
Fax:+86-22-8789-0344
[email protected]

2012 Loop Telecommunication International, Inc.


Version 81 6 JUNE 2012

All Rights Reserved


Subject to change without notice

29

You might also like