GUNTAMATIC Prospectus Englisch 05
GUNTAMATIC Prospectus Englisch 05
GUNTAMATIC Prospectus Englisch 05
GUNTAMATIC Biomass
Boiler Heating Range
Well established
Holistic thinking
With more than 120 sales and service agents in 17 countries, we are well established across Europe. We have built
a reputation for high-quality products from development
through to production and from sales through to service.
As a systems provider we develop and produce highly durable and efficient boilers. The highly economical BIOSTAR range of pellet boilers is a perfect example.
Established:
Company structure:
Sales and service agents:
Sales agents:
Equity ratio:
1963
Family-owned
120
In 17 countries
100 %
Our aim is
to do
what we are
best at
making
innovative,
safe and
reliable
products.
Contents
The better the product, the lower the operating costs. This is
why we pay attention to every detail in production.
Biostar
Biocom and Powercorn
Powerchip
BMK
PRO
Technical Information Biostar
Technical Information Biocom
Technical Information Powerchip
Technical Information PRO
Technical Information BMK
Guarantees and service levels
4
6
8
10
12
14
16
18
20
22
23
Discover the
BIOSTAR Family
Our BIOSTAR systems are the first series-produced, low-temperature wood
pellet boilers and feature leading technologies based on many years of
research and development. The latest generation of boilers have touchscreen control panels, our highest ever heating efficiencies and an
unrivalled standard of usability.
Highly adaptable
NO BUFFER NEEDED
Perfect combustion
The sophisticated control software ensures that the hot air fan
ignites the fuel quickly and efficiently. Grain or wood pellets
are burned at the ideal degassing temperature of approx.
650C so that the formation of clinker is avoided. A moving,
self cleaning step grate provides for the right amount of
movement in the bed of glowing fuel and the easy removal
of ash. The combustion gases produced are cleanly
converted into energy in a generously dimensioned
secondary combustion zone using secondary air.
Experience the
POWERCHIP boiler range
The user-friendly and ultra-efficient POWERCHIP range offers unique fuel
flexibility. These boilers will burn wood chips, wood pellets, grain or
miscanthus and fuel type can be changed at the touch of a button. They are
especially suitable for factories, schools, agricultural facilities and
district heating schemes. With touch-screen control panels they are also
very easy to operate.
Perfect combustion
The combustion gases are cleanly converted into hot water in a specially developed heat exchanger and dust removed by an efficient vacuum separator. The adjoining
jacket-and-tube heat exchanger constantly cleans itself
using moving turbulators and converts every degree of heat
produced.
Maximum safety
Wood chips, wood pellets, miscanthus or grain are conveyed by the fuel store feed auger, which is monitored by
a burnback-inhibiting chute with safety cover into the feed
auger. A sophisticated lambda control constantly optimises
the fuel feed rate. Additional operational reliability is provided by the fill-level indicator in the boiler.
The integral flue draught fan not only provides exactly the
right amount of air but also creates a constant draw in the
firebox. In conjunction with the burnback-inhibiting fuel chute and a tested fire safety flap, complete burn-back protection is provided for. The touch screen control panel offers
fault diagnosis and the option of remote monitoring from
your mobile phone ensures you are always in control.
10
BMK Future-proof
heating
The new BMK is the ideal solution for anyone looking for an innovative
and solid log boiler. It is exceptionally user-friendly, durable and sets new
standards in terms of efficiency and reliability.
11
12
THE PRO
INDUSTRIAL BIOMASS PLANT
THE PRO SERIES OFFERS UNRIVALLED LEVELS OF FUEL ECONOMY AND SAFETY FOR
Medium to large scale WOOD PELLET AND WOOD CHIP HEATING. THANKS TO THE
MODULAR DESIGN, THESE medium to large scale SYSTEMS ARE VERY FLEXIBLE AND
OFFER HEAT OUTPUTS OF UP TO 1000 KW.
13
MAXIMUM SAFETY
SELF CLEANING
14
biostar
Technical data
and specifications
Biostar Flex-Vacuum fuel outfeed
1. Door to ash bin
2. Grate cleaning plate
3. Primary Air
4. Self-cleaning grate
5. Secondary air
6. Spiral jet
7. Burn back proof drop shaft
8. Combustion zone
9. Automatic heat exchanger cleaning
10. Cleaning motor
11. Hot air ignition
12. Ceramic insulation
13. Full insulation
14. Turbulator
15. Tubular heat exchanger
16. Extraction draught fan
17. Flue gas sensor
18. Lambda probe
19. Touch screen control panel
20. Fill level sensor
21. Motor
22. Drive
23. Suction fan
24. Hopper tank
25. Conveyor auger for pellets
26. Monitoring sensor
27. Rotary sluice valve
Modulating bio
combustion control
Perfect modulation at peak efficiency
from 26-100%, enables the boiler to automatically adjust to suit heat demand.
This avoids cold starts, lengthens
the boilers working life, drives high
combustion efficeincies, and leads to
reduced fuel consumption.
Heat exchanger
15
min. 170
1056 *
1056*
914
914
1950
1950
1567
1567
1343
1343
1720
1720
min. 250
Length of storage
1080- 1,559
1559
= FLEX
1,080
= FLEX
1 1
1560- 2,039
2039
= FLEX
1,560
= FLEX
1.51,5
2040- 2,519
2519
= FLEX
2,040
= FLEX
2 2
2520- 2,999
2999
= FLEX
2,520
= FLEX
2.52,5
3000- 3,479
3479
= FLEX
3,000
= FLEX
3 3
3480-
auf Anfrage
3,480
= On= request
Vacuum tube
1950
1950
120
120
RR
130
RR 130
min. 420
max. 850
min. 400
7.5
8.3
11
14
Width
2.1
2.9
2.5
2.9
Depth
2.1
1.7
2.5
2.9
Height
min. 200
Filling and
air-extraction
pipes
min.
200
Width
Height
Rigid steel
plate floor
min. 500
Technical data
12
15
23
Pellets ENPlusS A1
Pellets ENPlus A1
Pellets ENPlus A1
Rated output
12
15
23**
kW
Minimum output
3.3
3.5
6.9
kW
Fuel
EU-Norm EN14961-2
0,1
0,1
0,15
mbar
38 - 80
38 - 80
38 - 80
Boiler weight
298
300
305
kg
600
600
600
l/h
mbar
Boiler temperature
11.7
17.2
37.7
automatic
automatic
automatic
Depth
38
38
38
litres
94.7
94.8
94.7
min.
200
16
biocom / Powercorn
technical DatA
and specifications
Biocom / Powercorn
1. Firebox door
2. Step grate - primary air
3. Combustion chamber
4. Fill level indicator
5. Spiral jet - secondary air
6. Gas combustion zone
7. Boiler lid
8. Turbulators
9. Heat exchanger tubes
10. Combustion fan
11. Heat exchanger cleaning mechanism
12. Flue pipe connection
13. Lamda probe
14. Thermostat
15. Cleaning/ grate drive
16. Ash auger
17. Ash bin
18. Touch screen control panel
19. Stainless steel liner for grain
17
Safety
fittings, 3/4
Length
of storage
1080
1559
= FLEX 1
1,080 -2039
1,559 ==FLEX
1560
FLEX 11,5
1,560 - 2,039 = FLEX 1.5
2040 2519 = FLEX 2
2,040 - 2,519 = FLEX 2
2520 2999 = FLEX 2,5
2,520 - 2,999 = FLEX 2.5
3000
-3479
FLEX 33
3,000
3,479 == FLEX
3480
FLEX 3,5
3,480 -3959
3,959 =
= FLEX
3.5
3960
-4439
FLEX 4
3,960
4,430 =
= FLEX
4
4440
FLEX 4.5
4,5
4,440 -4919
4,919 =
= FLEX
4920
FLEX 55
4,920 -5399
5,399 = FLEX
1030
1030
Sensor for
safety fittings
1890
1890
721
721
Boiler sensor
476
476
769
769
780
780
Additional
connection,
Flow, 1
min.
400
790790
min.
500
1474
1474
min.
800
980
980
min.
500
min. 420
max. 850
Width 300 mm
Height 250 mm
1030
1030
780
780
The vacuum system picks up the pellets at the end of the outfeed
auger and conveys them to the fuel hopper.
min.
400
min.
400
The storeroom does not have to be directly adjacent to the boiler room. The vacuum tube can span
distances of up to 25 m.
7.5
8.3
11
14
Width
2.1
2.9
2.5
2.9
2.1
1.7
2.5
2.9
Depth
Height
min. 200
Filling and
air-extraction
pipes
Width
Height
1.9-2.5 m
Rigid
steel plate
floor
Technical data
min.
200
Depth
min.
200
min. 500
BIOCOM 30
BIOCOM 40
POWERCORN 30
BIOCOM 50
BIOCOM 75
BIOCOM 100
POWERCORN 50 POWERCORN 75
Fuel BIOCOM
Wood pellets ENPlus A1 and A2
EU-Norm EN14961-2
Fuel POWERCORN
Wood pellets ENPlus A1 and A2; Grain NORM M7139*** (Miscanthus and agricultural pellets****)
Boiler output: Wood pellets
7-30
9-40
12-50
22-75
22-100
kW
Boiler output: Grain (with slaked lime additive) 7-25
12-40
21-70
Required flue draught
0.15
0.15
0.15
0.15
0.15
mbar
Boiler temperature Wood pellets
50-80
50-80
50-80
60-80
60-80
C
Boiler temperature Grain
70-80
70-80
70-80
Return temperature Wood pellets
>40
>40
>40
>45
>45
C
Return temperature Grain
>55
>55
>55
Pump (RA60 with thermal store)
Pump (return boost with thermal store)
Return boost
Water capacity
128
128
147
256
256
litres
Operating pressure (max.)
3
3
3
3
3
bar
Ash bin, "grate"
60
60
60
80
80
litres
Ash bin, "heat exchanger"
12
12
12
12
12
litres
Flue connection diameter
150
150
150
180
180
mm
*
**
*
**
*
**
Weight
550 / 562
553
585 / 667
865 / 890
865
kg
*
**
Weight of lower unit
340
340
340 / 410
430
430
kg
Weight of heat exchanger
180* / 192**
183
215* / 227**
405
405
kg
Weight of feed auger
70
70
70
70
70
kg
Weight of drive unit
26
26
26
26
26
kg
Weight Including feed auger
40
40
40
40
40
kg
Safety heat exchanger
Yes
Power supply
230 V / 13 A
In cascade mode, up to four boilers can be connected
*
Details for BIOCOM range
**
Details for POWERCORN range
***
The boiler is capable of burning grain if permitted by local regulations and the specified emission limits are complied with.
****
The systems are fundamentally suitable for use with organic fuels; however there are no specific type approvals available. The possibility of such
use should be verified in each particular case with reference to the relevant local regulations and emission limits.
18
Powerchip
technical DatA
and specifications
Powerchip
1. Firebox door
2. Step grate - primary air
3. Combustion chamber
4. Fill level indicator
5. Spiral jet - secondary air
6. Gas combustion zone
7. Boiler lid
8. Turbulators
9. Heat exchanger tubes
10. Combustion fan
11. Heat exchanger cleaning mechanism
12. Flue pipe connection
13. Lamda probe
14. Thermostat
15. Cleaning/ grate drive
16. Ash auger
17. Ash bin
18. Touch screen control panel
19
21
23
20
22
19
Powerchip up to 50 kW
W
1574
790
950
950
385
Temperature relief
connections 3/4
Return 5/4
Minimum room height 2200
Sensor for
temperature relief 3/4
Boiler sensor
721
721
Flow 5/4
Additional
connection 1/2
1670
1670
Pivot point
RR 150
769
769
778
778
476
476
Powerchip187575 kW or over
1090
1090
1875
3855
38
980
980
Flow 2
Minimum room height 2400
Flow 2
Temperature relief
connections 3/4
850
850
1/2
1/2
18
45
1845
Return 2
Return 2
Pivot point
RR 180
782
782
778
778
476
476
min. 500
min. 500
15744
157
min. 400
180
1175
1175
min. 800
Pivot point
950
Technical data
Fuel
Boiler output
Wood chips 7 - 30
Wood pellets 7 - 30
Grain 7 - 25
Miscanthus 7 - 25
0.15
Powerchip 75
Powerchip 100
NORM M7133
EU-Norm EN14961-2
NORM M7139
kW
kW
kW
kW
mbar
Boiler temperature
65 - 80 (70 Grain)
65 - 80 (70 Grain)
65 - 80 (70 Grain)
65 - 80 (70 Grain)
Return temperature
55
55
55
55
Return boost
Water capacity
Operating pressure (max.)
Ash bin, "grate"
Ash bin, "heat exchanger"
System width
Flue pipe connection diameter
Overall weight (without feed auger)
Weight of lower unit
Weight of heat exchanger
Weight of feed auger
Temperature-relief heat exchanger
Power supply
128
3
60
12
1574
150
550
340
180
75
147
3
60
12
1574
150
585
340
215
75
256
3
80
12
1875
180
865
430
405
75
256
3
80
12
1875
180
865
430
405
75
litres
bar
litres
litres
mm
mm
kg
kg
kg
kg
Yes
400 V / 13 A
In cascade mode up to four different boilers can be combined. * In order to ensure fault-free operation, the G50 standard criteria must be precisely complied with. Therefore, please make sure wood chipper blades are sharp or alternatively use G30 woodchips. ** additional equipment required.
*** additional lining required.
20
11
4
10
4
7
15
14
12
8
13
Length of storage
1,080 - 1,559 = FLEX 1
1950 cm
mind. 2.5 m
Vacuum
Tube
1.6 m
max. 850 cm
min. 420 cm
21
Agitator Diameter
Rhr
1.5 towerks5.0 m
durchmes ser
1,5 bis 5,0 m
Auger
length up to 7bis
m maximum
Schnec
kenlnge
max. 7 m
1700
1700
2300
2300
250
250
Mountedrohrabgang
flue outlet
(Rauch
drehba r)
2100
2100
Technical data
188
199,5* / 250**
0,1
60 - 85
55
600
max. 3
max. 240
250
approx. 2,000
Yes
400 V / 20 A
NORM M7133
EU-Norm EN14961-2
EU-Norm EN14961-2
kW
kW
0,1
60 - 85
55
1.200
max. 3
max. 480
2x 250
approx. 4,000
Yes
400 V / 20 A
0,1
60 - 85
55
1.800
max. 3
max. 720
3x 250
approx. 6,000
Yes
400 V / 20 A
0,1
60 - 85
55
2.400
max. 3
max. 960
4x 250
approx. 8,000
Yes
400 V / 20 A
mbar
C
C
litres
bar
litres
mm
kg
22
bMK
technical DatA
and specifications
BMK
1. Large primary combustion chamber
2. Cast iron grate
3. Ash bin
4. Preheated secondary air
5. Preheated primary air
6. Turbo secondary combustion area
7. Turbulators
8. Cleaning lever
9. Combustion fan
10. Flue pipe connection
11. Touch screen control panel
12. Low energy servo motos for primary and secondary air
13. Thick all round insulation
14. Secondary gas duct
15. Automatic Ignition Option
Heat exchanger:
Dimensions D
Technical data
BMK 20/30
BMK 40/50
20/30
40/50
kW
Width, D
973
973
mm
Height, E
1440
1640
mm
Depth, F
940
940
mm
166
215
litres
Heating output
Boiler dimensions with insulation
Fuel capacity
Fuel box width
370
370
mm
580
580
mm
Dimensions C
Water capacity
125
175
Liter
Dimensions A
bar
630
730
kg
R 1 1/4
R 1 1/4
Zoll
1047 / 568
1247 / 568
mm
1334
1534
mm
150
150
mm
0.12
0.12
mbar
Width
965
965
mm
Height
1310
1510
mm
795
795
mm
230V / 13 A
230V / 13 A
Depth
Power supply
Dimensions B
160
Dimensions E
Dimensions F
23
Guarantees and
service levels
As a market leader, we pay special attention to the build
quality of each and every boiler. If you should encounter
any problems we will make sure you are offered a suitable
solution as quickly as is possible.
Because of our approved network of service agents we
can offer the highest levels of customer service available.
GUNTAMATIC
heating
solutions
BIOSTAR
Low-temperature pellet boiler
BMK
Log boiler
Heating GmbH
Bruck 7 . 4722 Peuerbach . Austria
Tel. 0043(0)7276-2441-0 . Fax 0043(0)7276-3031 . [email protected] . www.guntamatic.com
06/2013 . Subject to printing errors and technical amendments.