Ultima: X Series Gas Monitors
Ultima: X Series Gas Monitors
Ultima: X Series Gas Monitors
SIL-2 d
e
Certifi
X Factors
1
Calibration
As with all gas monitors, Ultima X Series Gas Monitors
must be calibrated periodically with the gas of interest to
ensure proper operation. The calibration process offers:
Easy-to-follow calibration instructions
displayed on monitor
Automatic adjustments
Date stamping
Selectable lockout of output signal during
calibration
Ability to calibrate at the installation location, or
remotely without systems interruptions (using
another base unit)
No need to open the enclosure during set-up and
calibration when using accessory calibrator, controller
or pushbutton
State-of-the-Art Display
Liquid crystal display conveniently alternates
between sensor reading and gas type and features
scrolling messaging, indicating ongoing diagnostic
checks such as sensor "end-of-life" condition.
World-Class Design
Engineering efforts feature a single-board design for
ultimate reliability and serviceability. The multipleentry mounting enclosure has been designed to be
separate from the electronics and sensor, allowing
for problem-free installation and servicing.
Ultima X3 Technology
[ X to the Power of 3 ]
PLC/DCS
[ProSoft-Tested]
Connect the X3 unit to
PLC/DCS control systems.
The X3 technology is
ProSoft-Certified. It has
been tested and found to
be compatible with AllenBradley PLC/ModBUS
connectivity by ProSoft
Technology, Inc.
Up to 3000 ft.
of 93 sensors
Any combination of electrochemical-, catalytic-, and infrared-type sensors are available
Scrolling display monitor scrolls through type and reading for all sensors attached
The Ultima X3 Monitor operates as a slave device on the network
Signal boost
Each sensor can be observed remotely up-to 3000ft. from the monitor
Universal 85-256VAC or 7-30VDC power supply available at remote condulet
ModBUS RTU Output
Industry-standard format
Provides an RS-485 half-duplex communication interface
Integration into PLC/DCS systems
Accessories
Power Supply
The Ultima X external power supply can power sensors remotely.
Internal power supply option is also available. One remote power supply
module can power:
Up to 5 electrochemical or oxygen sensors.
Up to 3 Combustible sensors
Pushbutton
The pushbutton allows the user to view various functions without the use
of the calibrator. The pushbutton allows the user to:
Acknowledge Alarms
Initialize Zero Calibration
Initialize SPAN Calibration
Initialize iCAL Calibration
Abort Calibration
Duct-Mount Kit
The Duct Mount Kit allows the user to monitor air within ductwork
using the Ultima XE, XA or XIR sensor. A quick-disconnect fitting
enables the calibration gas to reach the sensor without having to
remove the duct-mounted sensor.
Pump
Sampling pumps are available to bring a remote sample to a sensor.
The sampling modules are available in GP and XP versions of aspirated
and pumped modules.
Calibrator
The Ultima Monitor Calibrator offers the industrys simplest method of
calibration, an easy-to-use three button device that allows calibration
and address-change of the Ultima X Series Monitor.
Controller
The Ultima Monitor Controller provides complete access to all features
through its full-function keypad. It offers the ability to set alarm levels,
change span gas values and display date of last calibration.
Ultima XA Gas Monitor Water- and CorrosionResistant, All-Purpose, Polycarbonate Gas Detector
with Display
The Ultima XA Gas Monitor offers:
Nema 4X rating
Light-weight (Only 1.5 lbs)
Gases
Gas Types
Instrument Division:
P.O. Box 427, Pittsburgh
PA 15230 U.S.A.
www.MSAgasdetection.com
In U.S.:
Phone: 1-800-MSA-INST
Fax: 1-724-776-3280
In Canada:
Phone: 1-800-MSA-INST
Fax: 1-905-238-4151
In Mexico:
Phone: 52 55 21 22 5770
Fax: 52 (5) 3 59 43 30
MSA International:
Phone: 412-967-3228
Fax: 412-967-3373
XE, XA
XIR
XE, XA
XIR
XE, XA
<5%/year, typical
2%/year, typical
<10%/year, typical
<1% Full Scale
XE, XA
XE, XA
XE, XA
XE, XA
XIR
XE, XA
XIR
XE, XA
XE, XA
XIR
2 years typical
3 years typical
5 years typical
1 year XE, XA; 2 years XIR
7-30VDC (oxygen and toxics)
7-30VDC @ 450mA maximum (combustibles)
7-30VDC @ 750mA maximum (combustibles)
Temperature Range
Drift
Zero Drift
Span Drift
Noise
Accuracy
Repeatability
Linearity
Response Times
T20 O2 & toxics
T50 O2 & toxics
T50 combust.
T90 combust.
T90 combust.
Humidity
Sensor Life
Oxygen & Toxics
Combust.
Combust.
Warranty
Power Input
XE, XA
XE, XA
XIR
Wiring Requirements
Combust.
XE, XA, XIR
Oxygen & Toxics
XE, XA
Oxygen & Toxics
XE, XA
Signal Output
XE, XA
XE, XA, XIR
Relay Contact Rating
Housing Entries
XE, XIR
XA
Physical
XE
XA
XIR
Approval Ratings
XE
(Includes X3
Technology)
XA
XIR
XE & XIR
XE, XA, XIR
3-wire
2-wire; no LEDs or relays
3-wire; LEDs and/or relays
4-20mA 2-wire current sink
4-20mA 3-wire current source
5amp @ 220 VAC; 5amp @ 30 VDC
Four conduit entries, 3/4" NPT or 25mm
One Entry
316 Stainless Steel; 10.4lbs (4.7kg)
6.3"W x 3.9"D x 10.3"L (160 x 99 x 261mm)
Polycarbonate; 1.5lbs (0.68kg)
5.1"W x 2.9"D x 9.4"L (130 x 76 x 239mm)
316 Stainless Steel; 10.8lbs (4.9kg)
12.6"W x 3.9"D x 5.7"L (320 x 99 x 144mm)
UL 1203 &
CSA C22.2-30
Class I, Div. 1, Groups A, B, C, & D
Class II, Div 1, Groups F, G
Class III
CSA C22.2 No. 152 Class I, Div. 1, Groups A, B, C, & D
Nema 4X rating
UL 1203 &
CSA C22.2-30
Class I, Div. 1, Groups A, B, C, & D;
Class II, Div.1, Groups E, F, & G;
Class III
CSA C22.2 No. 152 Class I, Div. 1, Groups B, C, & D
EN 50018
Class I, Zone 1, Group IIC
CE Low Voltage Directive: 73/23/EEC
CE EMC Directive: 89/336/EEC