Chapter 6-Connections PDF
Chapter 6-Connections PDF
Chapter 6-Connections PDF
Bolted Connections
Bolted connections are employed mainly in structures subjected under reversed and vibration loads, over all in
members with heavy conditions.
The black hexagon bolt shown in the Figure below with nut and washer is the most commonly used structural
fastener.
If the force P is large enough, the bolt could fail in shear; breaking by sliding of its fibres along the shear planes.
The area of the steel bolt resisting the failure is the circular area of the bolt shank. The resisting force depends
upon the number of shear planes.
2.
3.
Tension in the direction of the acting force along the shank of the bolt.
Shear and bearing should be present at the same time in the joint. It will be seen that bolt may be designed on the
basis of their strength in shear or their strength in bearing.
In actual design the lesser of these two values will have to use.
When designing of this type of connection, the following questions should be asked:
1. Is the connection in single or double shear?
2. What is the safe appropriate shear load on one bolt?
3. What is the safe bearing load on one bolt?
Chapter 6- Connections
Tensile area
(mm2)
84
157
245
303
353
459
561
Shank area
(mm2)
113
201
314
380
452
572
707
Shear capacity
Provided that no reductions are required for long joints the shear capacity for shear plane F v,Rd of a bolt shall be
taken as:
0.6 fub
but
0.87 f yb
Bearing capacity.
The effective capacity of a bolt in bearing on any ply shall be taken as the lesser of the bearing capacity of the bolt
and the bearing capacity of the connected ply.
The bearing capacity of the bolt.
Fbb, Rd dtfbb, d
Where d
is the nominal diameter of the bolt
t
is the thickness of the ply (the minimum thickness on one part of the joint)
fbb,d is the design bearing strength of the bolt.
The bearing capacity of the connected ply.
Where fbp,d
e1
fbb, d
0.9 fub f yb
Where fyb
fub
M
fy
fu
Fbp, Rd dtfbp, d
and
fbp, d
0.8 fu f y
M2
Ft , Rd ft , d As
ft , d
0.7 fub
but
1.0 f yb
The partial safety factor for all the cases are M = 1.25
Chapter 6- Connections
Fv, Sd
Fv.Rd
Ft , Sd
Ft , Rd
1.4
Where Fv,Sd is the design shear force per bolt for the ultimate limit state
Ft,Sd
is the design tensile force per bolt for the ultimate limit state
Fv,Rd is the shear capacity per bolt
Ft,Rd
is the tension capacity per bolt.
Notes:
1. The size of the holes are given in Table 6.1
2. The edge distances and spacing of holes for fasteners are given in Table 6.2
d+1
d+2
d+2
d+3
d+1
d+2
d+2
d+3
d+1
d+2
d+2
d+3
d+4
d+5
d+6
d+8
d+4
d+6
d+8
d + 10
2.5d
2.5d
2.5d
2.5d
Edge distances
Minimum
edge
distance
e1
e2
Hole distances
e1
1.25 do
e2
e1
e2
Minimum
hole
distance p1
2.5 d0
Maximum
Hole
distance p1
in
unstiffeded
plates
14 t
or 200
mm
1.4 do
4
Maximum
Edge
distance
12 t
or
150 mm
Chapter 6- Connections
Bolt grades.
The grade of the bolt is given by two figures separated by a point. The first figure is 1% of the minimum ultimate
strength in N/mm2 and the second is 1/10th of the percentage ratio of the minimum yield strength. Thus 5.6 grade
means that the minimum ultimate strength is 500 N/mm2 and the yield strength is 60% of this strength which is 300
N/Mm2. the nominal values of the yield strength fyb and the ultimate strength fub to be adopted as characteristic
values in calculations are given below.
Bolt grade
fyb (N/mm2)
fu (N/mm2)
4.6
240
400
4.8
320
400
5.6
300
500
5.8
400
500
6.8
480
600
8.8
640
800
10.9
900
1000
Welded Connections
Welding is the process of materials(usually metal) by heating them to a suitable temperatures
such that the materials unite into one material. Arc welding is the general term for the many
processes that use electrical energy in the form of an electrical arc to generate the heat necessary
for welding. The welding process is shown in the following figure.
Types of weld.
The commom types of weld are illustrated in Table 6.3. To study the behaviour of the joints they are divided mainly
into 2 types, Butt weld and Fillet ones.
Butt welds. This type is used mostly to join the ends of plates of same or similar thickness. You can use it also in
welding of beams with sections I or C. Their disadvantage consists in to achieve complete penetration. For foils
thickness bigger than 10 mm it is necessary to prepare the borders appropriately, that wich requires of special cares
and appropriate facilities. This work is carried out in shops where the welding process can be controlled with
quality.
Chapter 6- Connections
Then, the tensile stress due to the axial force P on the welding section 1 1 is: f st
P
P
ft , it is similar
Lst
bt
to the tension that take place in a section 2 2 for the base metal. Usually if the resistance of the material of
contribution of the electrode is bigger than that of the base netal, the resistance of the joint is guaranteed and it is not
necessary further calculation.
Fillet welds.
Fillet welds may be used for connecting parts where the fusion faces form an angle of between 60 0 and 1200.
Smaller angles are also permitted. However, in such a cases the weld shall be considered to be partial penetratrion
butt weld.
Fillet welds terminating at the ends or sides of parts should be returned continuously around the corners for a
distance of not less than twice the length s of the weld unless access or the configuration renders this impracticable.
This detail is particularly important for filled welds on the tension side of parts carrying a bending load.
In lap joints the minimum lap shall be no less than 4t where t is the thickness of the thinner part joined. Single fillet
welds should only be used where the parts are restrained to prevent opening of the joint.
As it is observed in the figure, the tensions that appear in the welding chord are of shear, being the points of the
ends (A and B) the most loaded for what reach the yiend point first. Then the interior points go reaching the yield
point gradually and in the moment of the failure, all the points of the welding chord will be working contributing the
maximum resistance evenly. Numerous researsh works show that the failure really happens for the half plane of the
cord, that which defines the efective area as the product of multiplying the effective with of the throat of the cord (a)
for the longitude of the chord.
Throat thickness.
The effective throat size a of a fillet weld shall be taken as the perpendicular distance from the root of the weld to a
straight line joining the fusion faces wich lies within the cross-section of the weld. It is not, however, be taken as
greater than 0.707 times the effective leg with s.
The throat thickness of a fillet weld should not be less than 3 mm.
Design Strength.
The codes usually use they calculate the maximum force that resists the unit of longitude.
The design strength Fw,Rd of a fillet weld per unit of length shall be obtained from:
Fw, Rd f vw, d a ; where f vw, d is the design shear strength of the weld and shall be determined from:
f vw, d
0.63 f ye
Mw
but f v, w
0.65 fu
Mw
Long joints.
In lap joints the design resistance of a fillet weld shall be reduced by multipliying it by a reduction factor Lw to
allow for the effects of non-uniform distribution of the stresses along its length.
This provision is not apply when the stress distribution along the weld corresponds to the stress distribution in the
adjacent base metal, as for esample, in the case of weld connecting the flange and the web of a plate girder.
Generally in lap joints longer than 150a reduction factor Lw should be taken as Lw,1 given by:
Lw,1 1.2 0.2L j /(150a) but Lw.1 1.0 ; where Lj is the overall length of the lap in the direction of
Chapter 6- Connections
Lw,2 1.1 Lw / 17 but 0.6 Lw,2 1.0 ; where Lw is the length of the weld in meter.
Types of elctrodes.
For a common structural steel, the AWS (American Welding Society) recommends electrodes types E 60 XX and E
70 XX. E denotes electrode, the first 2 numbers represent the tensile strength of the electrode in Ksi (kilopound
per square inches); the Xs refer to factors such as the suitable welding positions, etc. Recommended power supply
etsthen for the electrodes abobe the tensile strength are 60 Ksi (414 Mpa) and 70 Ksi ( 483 Mpa) respectively.
Chapter 6- Connections
Examples on connections
Bolted connections.
Example 1. The connection shown in the Figure below is subjected to a design tensile force of 240 kN. The steel
Grade is Fe 430, the bolt Grade 8.8 and its diameter is 20 mm. Check that the connection is adequate.
Fv, Rd f vd As
2 x0.6 fub As
Mb
2 x0.87 f yb As
Mb
Fbb, Rd
dt 0.9 fub f yb
Mb
Chapter 6- Connections
1
e1 t fbb, d ( per bolt)
2
dt 0.8 fu f y
Fbp, Rd d t fbp, d
Fbp, Rd
M2
20 x15x0.8430 275x103
240
Fbp, Rd
135.36
120 kN. Ok
1.25
2
1 50 x15x0.8430 275x103
and x
169.2 135.36 OK
2
1.25
( governs design)
Fbp, Rd
d t 0.8 fu ft
1
e1t fbp, d
2
20x70.8430 275x103
240
63.2 kN
60 kN ( per angle)
1.25
2 x2
1 50 x7 x0.8430 275x103
x
79.0 63.2 OK
2
1.25
and
Example Nr 2.
Check that the secondary girder to primary girder connection by means of angles shown in the figure below is
adequate. All data required are provided in the figure.
Main girder, Secondary girder and Angles L 90 x 9 with Steel Grade F e 430, fu = 275 N/mm2.
Bolts Grade 8.8, fyb = 640 N/mm2, fub = 800 N/mm2; Diameter 22 mm.
Bolt area at the bottom of the thread: As = 303 mm2.
Applied load: Shear force V = 890 kN (at the centreline of the web of the main girder).
Solution:
Diameter of holes d0 = d + 2 = 22 + 2 = 24 mm.
Minimum edge distance, e1 = 1.25 d0 = 1.25 x 24 = 30 mm < 40 mm. OK.
Minimum hole distance, p1 = 2.50 d0 = 2.50 x 24 = 60 mm = 60 mm OK.
Maximum edge distance, e1 = 12 t = 12 x 9 = 108 mm > 40 mm OK.
Maximum hole distance, p1 = 14 t = 14 x 9 = 126 mm > 60 mm OK.
Shear Capacity of bolts.
Assumptions: - one shear area per bolt.
- threads area in the shear plane.
Chapter 6- Connections
Fv, Rd f vd
Shear capacity of a bolt:
0.6 fub As
Mb
0.87 f yb As
Mb
0.6 x800x303x10
890
116.4
49.4 kN
1.25
2 x9
0.87 x640x303x103
and
135 116.4 kN OK
1.25
Fbb, Rd d t fbb, d
dt 0.9 fub f yb
Mb
Fbp, Rd
dt 0.8 fu f y
Mb
1.25
1 e t f
2
OK
bp, d
89.3 kN 49.4 OK
1.25
1 40x9 x0.8430 275x103
and x
81.2 89.3 but 49.4 kN OK .
2
1.25
Capacity of connection Secondary Girder and connection Angle (welded).
f R , w f vw, d 0.63
f ye
Mw
but 0.65
fv, w
Mw
890 kN
14.04 kN / cm 2
63.9 cm 2
fb, w
fu
Wweld
2 x0.566x562
591.66 cm 3
6
8010 kN cm
13.54 kN / cm 2
591.66 cm 3
Chapter 6- Connections
f R, w
fb2,w f v2,w
43
22.36 kN / cm 2
1.25
Welded Connections.
Example Nr 1. (Checking problem).
In the beam to column connection shown in the figure, the steel plate is supporting a support factored reaction of
525 kN from the beam. If the size of the weld is 8 mm and steel Grade Fe 360, check if the connection is adequate.
f vw, d
0.63 f ye
Mw
Fw, Rd f vw, d a
0.65 fu
Mw
In most practical cases, the quality of the electrodes are greater than that of the base metal and then the ultimate
tensile strength of the weaker part joined, that is, the base metal govern the design. Therefore the second statement
of the equation is checked.
0.65x360
x5.66 1059.55N / mm
1.25
3
And the total resistance force F 1059.55 N / mmx818 mmx10 866 kN 525 kN OK .
Fw, Rd
10
Chapter 6- Connections
2
2
F
F b F1b F1 F ; Thus F2
3
3
3
therefore; F1 is taken by two chord (filled weld) length L1each and F2 is taken by the lower two fillet weld length L2
each.
Example: Compute the welds required for connecting two angles 75x75x8 mm to a gusset plate with a thickness 10
mm. The factored tensile force in the angle is 450 kN. The material is steel Grade 430.
Geometry, Materials.
Plate and angles Grade 430 steel,
fy = 275 N/mm2 ;
Size of the welds 8 mm; take s = 6 mm.
Throat thickness a = 0.707 x 6 = 4.24 mm.
fu = 430 N/mm2
2
2
F1 x 450 kN 300 kN
3
3
450
F2
150 kN
3
F1
2). Design strength per unit length. (Suppose the weaker part is the base steel).
Fw, Rd
0.65x 430
x 4.24 948N / mm.
1.25
L1
F1
2 ( fillet welds ) Fw, Rd
300x103 N
158.2 mm
2 x948 N / mm
11
Chapter 6- Connections
Principle: The flanges take the acting bending moment and the web takes shear force.
M is discomposed into a couple of forces F.
F = M/h acting on the flange levels.
Then F
284 kN m
532 kN .
0.533 m
A 180tc, p
tc , p
-
Mo x532x103
N pl , Rd
Af y
Mo
532 kN
1.1x532x103
2128 mm 2
275
fy
2128 mm 2
11.82 mm take 12 mm.
180 mm
suppose size of the weld 8 mm < 12 mm.
throat thickness a 0.707x8 mm 5.66 mm
0.65x 430
x5.66 1266 N / mm
1.25
F
532x103 N
Fw, Rd
0.65x 430
x 4.24 948N / mm
1.25
3
The total resistance force 948N / mm x 350 mm x 10 331.8 kN 142 kN OK .
Strength per unit length
12
Fw, Rd
Chapter 6- Connections