_ZXL004_ExeZeroReset (1/3)
ZXL
-004
Execute Zero Reset: _ZXL004_ExeZeroReset
Basic
function
Symbol
Executes a zero reset for the Smart Sensor.
Start trigger
Busy Flag
Unit selection
Serial Port No.
File name
Applicable
models
Function
description
FB
precautions
Busy Flag
Normal end
Error end
Lib\FBL\omronlib\LaserSensor\ZXL\_ZXL004_ExeZeroReset10.cxf
Laser Sensor
ZX-LDA-N
CPU Unit
Conditions
for usage
_ZXL004_ExeZeroReset
(BOOL)
(BOOL)
EN
ENO
(INT)
(BOOL)
UnitSelect
BUSY
(INT)
(BOOL)
PortNo
OK
(BOOL)
NG
CS1*-CPU**H Unit version 3.0 or higher
CJ1*-CPU**H Unit version 3.0 or higher
CJ1M-CPU** Unit version 3.0 or higher
CP1H
CP1L (except 10 points CPU)
CS1W-SCU21-V1, CJ1W-SCU21-V1, CJ1W-SCU41-V1 Unit Version 1.2 or higher
CS1W-SCB21-V1 and CS1W-SCB41-V1 Unit Version 1.2 or higher
Serial
Communications
Units/Boards
CX-Programmer
Version 5.0 or higher
External Connections
Can be used only for 1:1 connections.
(FB "_ZXLN***" can be used for 1:N connections)
Communications must be within one network and cannot cross to another network.
Communications Settings
The communications settings of the serial port must be the same as those of the Laser Sensor.
The communications settings of the specified serial port can be set to the default Laser Sensor settings
using the Set Communications Port (_ZXL600_SetComm) function block, and the other Laser Sensor
settings using the Set Serial Gateway Mode (_SCx604_SetPortGATEWAY) function block.
CPU Unit Settings
PLC Setup: Shared Settings for Communications Instructions in FBs
Communications Instruction Response Timeout Time (default: 2 s) 5 s recommended
Number of retries (default: 0)
Shared Resources
Communications ports (internal logical ports)
When the Start Trigger turns ON, a zero reset is executed for the Smart Sensor connected to the Serial Port
specified by the Connection unit and Serial port No.
The FB is processed over multiple cycles. The BUSY output variable can be used to check whether the
FB is being processed.
OK or NB will be turned ON for one cycle only after processing is completed. Use these flags to detect
the end of FB processing.
Time Chart
Start Trigger
ON
OFF
Busy Flag
ON
OFF
Normal End (OK) or
Error End (NG)
ON
OFF
FB execution completed.
EN input
condition
Restrictions
Input
variables
Output
variables
Connect EN to an OR between an upwardly differentiated condition for the start trigger and the BUSY
output from the FB.
Always use an upwardly differentiated condition for EN.
If the input variables are out of range, the ENO Flag will turn OFF and the FB will not be processed.
This FB requires multiple cycles to process. Always connect an OR including the BUSY output variable
to the EN input variable to ensure that the FB is processed to completion (see Symbol).
Do not turn the BUSY output variable ON or OFF outside the FB.
_ZXL004_ExeZeroReset (2/3)
Other
Application
example
Up to 3 seconds may be required for this FB to be completed (i.e., from EN turning ON until the OK or
NG Flag turns ON).
Whether the zero reset value is written to EEPROM is determined by the Zero Reset Memory Setting,
just as it is when the zero reset is used for the Smart Sensor.
Set the Zero Reset Memory Setting to OFF. There is a limit on the number of times that the zero reset
value can be written by executing a zero reset, just as there is for writing parameters (1 million writes).
An execution error will occur if the Smart Sensor cannot execute the zero reset function, e.g., if the
display value is not being held or the detection range would be exceeded.
Additional Information: Section 6 Auxiliary Functions in the ZX-L-N Series Smart Sensors Laser Type
Users Manual (Z197)
A Smart Sensor is connected 1:1 to serial port 1 on a Serial Communications Board (SCB).
When bit A turns ON, a zero reset is performed for the Smart Sensor.
Connection unit: SCB (#BBBB)
Serial Port No.: 1
SCB
CPU
Smart Sensor
SCU
1:1 connection
Bit A
Bit B
Unit selection
#BBBB
Serial Port No.
&1
_ZXL004_ExeZeroReset
(BOOL)
(BOOL)
EN
ENO
(INT)
(BOOL)
UnitSelect
BUSY
(INT)
(BOOL)
PortNo
OK
(BOOL)
NG
Busy Flag
Bit B
Normal end
Bit C
Error end
Bit D
Bit C
Processing for operation commands
Related
manuals
Related FBs
ZX-L-N Series Smart Sensors Laser Type Users Manual (Z197)
Using the Zero Reset Function in Section 6 AUXILIARY FUNCTIONS
ZX Series Smart Sensors Operation Manual (Z157)
3-3-4 Zero Reset Function
4-3-4 Zero Reset Function
Release Zero Reset (_ZXL005_StopZeroReset)
_ZXL004_ExeZeroReset (3/3)
Variable Tables
Input Variables
Name
EN
Variable name
EN
Data type
BOOL
Default
Range
Unit selection
Serial Port No.
UnitSelect
PortNo
INT
INT
&0
&1
At right.
&1 to &2
Description
1 (ON): FB started.
0 (OFF): FB not started.
Specify the Unit and the serial port.
Only serial port 2 of CP1H/CP1L M-type
CPU unit is possible to use this FB.
Connected to CPU Unit
Unit selec tion
Serial port No.
#FFFF
Not access ed.
(CP1H/CP1L-M: Serial Port2
CP1L-L14/20: Serial Port1)
Connected to Serial Communication B oar d(SCB)
Unit selec tion
#BBBB
Serial port No.
&1: Serial Port 1
&2: Serial Port 2
Connected to S eri al Commu nication Unit( SCU )
Unit selection
SCU Unit No. (&0 to &15)
Serial port No.
&1: Serial Port 1
&2: Serial Port 2
Output Variables
Name
ENO
(May be omitted.)
Busy Flag
Variable name
ENO
Data type
BOOL
BUSY
BOOL
Normal end
OK
BOOL
Error end
NG
BOOL
Range
Description
1 (ON): FB processed normally.
0 (OFF): FB not processed or ended in an error.
Automatically turns OFF when processing is
completed.
Turns ON for one cycle when processing ends
normally.
Turns ON for one cycle when processing ends in an
error.
Internal Variables
Internal variables are not output from the FB.
If the NG Flag from the FB turns ON, the following internal variables can be monitored to obtain information on the error.
Name
Variable name
Data type
Range
Description
Error code
ErrorCode
WORD
The results information from the Smart Sensor is
output to the Error Code.
See below.
Error Code Details
Code
Contents
#0000
Normal end
#2203
Operation error
#2204
Version History
Version
1.00
Operation error
Date
2004.6.
Meaning
A setting is incorrect. Refer to the Smart Sensor Operation Manual for setting
error conditions for teaching and the zero reset function.
The Sensor is not in RUN mode.
Contents
Original production
Note
This manual is a reference that explains the function block functions.
It does not explain the operational limitations of Units, components, or combinations of Units and components. Always read
and understand the Operation Manuals for the systems Units and other components before using them.