Water Flow Test: Case Study
Water Flow Test: Case Study
Water Flow Test: Case Study
Case Study: Water Flow Test FLUXUS F601 Portable Flow Meter
New Ross, Co. Wexford, Ireland
Problem
Our Customer wanted to prove his water pump The Customer expected the water flow of 300NCMH
performance. and this value proved to be correct. We attach the test
report from this measurement.
Solution
The solution was the portable FLUXUS F601 - a robust The FLUXUS F601 Portable Flow Meter is an ideal
clamp-on flowmeter which is suitable for the non- tool for service work and quick control ultrasonic
invasive flow measurements. Clamp-on-transducers are measurements. The measurement is pressure
quickly fixed on the pipe, without process interruption independent and can take place on pipes of almost any
and without production stop. materials and on almost any liquid.
Customer Name
MODE: STORED
NAME: SCANDATA
CHAN: 1 (A:)
\COMMENTS
\PARAMS
Par.Record:
Pipe:
Roughness: 0.1 mm
Medium: Water
Medium Temp.: 7C
Damping: 30 s
300,00
280,00
260,00
240,00
220,00
200,00
Volume Flow [m3/h]
180,00
160,00
140,00
120,00
100,00
80,00
60,00
40,00
20,00
0,00