AWS D1.2 Guides
AWS D1.2 Guides
AWS D1.2 Guides
com
AWS D1.2 (Structural Welding Code-Aluminum)
Quick Review on Essential Variables
1-Guide (General)
AWS D1.2, Table 3.1 A change in the mode of metal transfer
for GMAW, a change from AC to DC (GTAW, GMAW) or
vice versa, a change from DCEN to DCEP (GTAW) or vice
versa, a change on shielding gases, M-number, etc. are change
of essential variables and need re-qualification of WPS (by
PQR).
2-Guide (Position)
AWS D1.2, Table 3.1 Vertical Welding: For any pass from
upward to downward or vice versa is essential variable. Also
change from forehand to backhand and vice versa (except as
stated in Table 4.4) are essential variables.
Position Qualified*
F
F, H
H
F, V
V
F, OH
OH
F, V, OH
All Positions
F
F, H
V
All Positions
F, H, OH
All Positions
WPSAmerica.com
AWS D1.2 (Structural Welding Code-Aluminum)
Quick Review on Essential Variables
3-Guide (Thickness/Diameter of Base Metal Range)
AWS D1.2, Table 3.4:
Test on Plate, CJP Groove Welds:
T: Thickness of Test Coupon Welded
T less than 1/8 in. (3 mm):
Qualified Thickness Range: T Min., 2T Max.
T from 1/8 in. (3 mm), to 3/8 in. (10 mm), incl.:
Qualified Thickness Range: 1/8 in. (3 mm) Min., 2T Max.
T over 3/8 in. (10 mm), to less than 1 in. (25 mm):
Qualified Thickness Range: 0.5T Min., 2T Max.
T 1 in. (25 mm) and over:
Qualified Thickness Range: 0.5T Min., Unlimited
PAGE 2 OF 6
WPSAmerica.com
AWS D1.2 (Structural Welding Code-Aluminum)
Quick Review on Essential Variables
4-Guide (Diameter of Base Metal Range)
AWS D1.2, Table 3.4
Test on Pipe (Tube), CJP Groove Welds:
Tests on Cyclically Loaded Tubular Structures:
A) Job Size Test Pipes:
A.1) Nominal Diam. Less than 24 in. (610 mm):
T less than 1/8 in. (3 mm):
Qualified Thickness Range: T Min., 2T Max.
T from 1/8 in. (3 mm) to 3/8 in. (10 mm), incl.:
Qualified Thickness Range: 1/8 in. (3 mm) Min., 2T Max.
T over 3/8 in. (10 mm), but less than 3/4 in. (19 mm):
Qualified Thickness Range: T/2 Min., 2T Max.
T from 3/4 in. (19 mm) and over:
Qualified Thickness Range: T/2 Min., 2T Max.
Qualified Nominal Diameter of Pipe (Tube) Size:
Test diameter and over
PAGE 3 OF 6
WPSAmerica.com
AWS D1.2 (Structural Welding Code-Aluminum)
Quick Review on Essential Variables
4-Guide (Diameter of Base Metal Range)
AWS D1.2, Table 3.4
Test on Pipe (Tube), CJP Groove Welds:
Tests on Cyclically Loaded Tubular Structures:
A.2) Nominal Diam. from 24 in. (610 mm) and over:
T from 1/8 in. (3 mm) to 3/8 in. (10 mm), incl.:
Qualified Thickness Range: 1/8 in. (3 mm) Min., 2T Max.
Qualified Nominal Diameter of Pipe (Tube) Size:
Test diameter and over
T over 3/8 in. (10 mm), but less than 3/4 in. (19 mm):
Qualified Thickness Range: T/2 Min., 2T Max.
Qualified Nominal Diameter of Pipe (Tube) Size:
24 in. (610 mm OD) and over
T from 3/4 in. (19 mm) and over:
Qualified Thickness Range: 3/8 in. (10 mm) Min., Unlimited
Qualified Nominal Diameter of Pipe (Tube) Size:
24 in. (610 mm OD) and over
B) Standard Test Pipes:
2 in. Sch. 80 or 3 in. Sch. 40
Qualified Thickness Range:
1/8 in. (3 mm) Min., 1/2 in. (13 mm) Max.
Qualified Nominal Diameter of Pipe (Tube) Size:
3/4 in. (19 mm OD) through 4 in. (100 mm OD)
6 in. Sch. 120 or 8 in. Sch. 80
Qualified Thickness Range: 3/8 in. (10 mm) Min., Unlimited
Qualified Nominal Diameter of Pipe (Tube) Size:
4 in. (100 mm OD) and over
PAGE 4 OF 6
WPSAmerica.com
AWS D1.2 (Structural Welding Code-Aluminum)
Quick Review on Essential Variables
4-Guide (Diameter of Base Metal Range)
AWS D1.2, Table 3.4
Test on Pipe (Tube), CJP Groove Welds:
Tests on Statically Loaded Tubular Structures:
C.1) Wrought material type
[6 thru 8 in. OD; T from 1/8 (3 mm) to 3/8 in. (10 mm) incl.]
Qualified Thickness Range:
1/8 in. (3 mm) Min., 2T Max.
Qualified Nominal Diameter of Pipe (Tube) Size:
3/4 in. (19 mm) Min., 16 in. (410 mm OD) Max.
C.2) Cast to Wrought or Cast to Cast material type
[3 thru 5 in. OD with T=3/16 in (5 mm)]
Qualified Thickness Range:
1/8 in. (3 mm) Min., 1/2 in. (13 mm) Max.
Qualified Nominal Diameter of Pipe (Tube) Size:
2 in. (50 mm) Min., 16 in. (410 mm OD) Max.
PAGE 5 OF 6
WPSAmerica.com
AWS D1.2 (Structural Welding Code-Aluminum)
Quick Review on Essential Variables
7-Guide (Joint)
AWS D1.2, Table 3.1: Essential Variables for Joints:
-A change in groove type (e.g., single-V to double-V), except
qualification of any CJP groove weld qualifies for any groove
detail as shown in Annex B1 except square groove joints
-A change in type of groove to a square groove
-A decrease of more than 5 degrees in the nominal groove
angle
-The omission, but not inclusion, of backgouging
-A change from permanent backing to temporary backing or no
backing
PAGE 6 OF 6