Acsr - Astm b232

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3
At a glance
Powered by AI
The document lists technical specifications for various types of aluminium conductors, including their dimensions, weights, breaking strengths, resistances and current ratings.

For each conductor type, the document lists the number and diameter of aluminium and steel wires, cross-sectional area, overall diameter, weight, breaking load, resistance and maximum current carrying capacity.

The standard lengths listed per reel for all conductor types is 2000 meters.

ACSR

ACSR

Aluminium Conductor Galvanized Steel Reinforced


Standard Specification : ASTM B 232 : 2001

Galvanized Steel
Aluminium

Technical Properties
Number / Diameter
of Wire
Type

Al

GSW

Calculated Cross
Section Area
Al

GSW

Approx.
Overall
Diameter

Approx.
Weight of
Conductor

Calculated
Breaking
Load

DC
Resistance
at 20 C
Max.
Ohm/km

Current
Carrying
Capacity *

Standard
Length
per Reel

No. / mm

No. / mm

mm

mm

mm

kg/km

kN

Thraser

76 / 4.43

19 / 2.07

1171.4

63.9

45.79

3,759

251.9

0.02477

1,654

1,000

Kiwi

72 / 4.41

7 / 2.94

1099.8

47.5

44.10

3,431

221.7

0.02642

1,592

1,000

Bluebird

84 / 4.07

19 / 2.44

1092.8

88.8

44.76

3,736

268.0

0.02656

1,596

1,000

Chukar

84 / 3.70

19 / 2.22

903.2

73.5

40.70

3,089

227.8

0.03216

1,429

1,000

Falcon

54 / 4.36

19 / 2.62

806.2

102.4

39.26

3,046

243.0

0.03601

1,344

1,000

Lapwing

45 / 4.78

7 / 3.18

807.5

55.6

38.22

2,670

187.4

0.03583

1,336

1,000

Parrot

54 / 4.25

19 / 2.55

766.1

97.0

38.25

2,892

230.5

0.03794

1,303

1,000

Nuthatch

45 / 4.65

7 / 3.10

764.2

52.8

37.20

2,529

177.6

0.03774

1,295

1,000

Plover

54 / 4.14

19 / 2.48

726.9

91.8

37.24

2,742

218.4

0.04002

1,261

1,000

Bobolink

45 / 4.53

7 / 3.02

725.3

50.1

36.24

2,400

170.5

0.03984

1,253

1,000

Martin

54 / 4.02

19 / 2.41

685.4

86.7

36.17

2,586

206.1

0.04238

1,218

1,000

Dipper

45 / 4.40

7 / 2.93

684.2

47.2

35.19

2,263

160.7

0.04216

1,210

2,000

Pheasant

54 / 3.90

19 / 2.34

645.1

81.7

35.10

2,435

194.1

0.04501

1,173

2,000

Bittern

45 / 4.27

7 / 2.85

644.4

44.7

34.17

2,133

151.6

0.04480

1,167

2,000

Skylark

36 / 4.78

1 / 4.78

646.0

17.9

33.46

1,919

117.2

0.04457

1,162

2,000

Grackle

54 / 3.77

19 / 2.27

602.8

76.9

33.97

2,280

184.2

0.04803

1,127

2,000

Bunting

45 / 4.14

7 / 2.76

605.8

41.9

33.12

2,004

142.4

0.04779

1,121

2,000

Finch

54 / 3.65

19 / 2.19

565.0

71.6

32.85

2,133

174.6

0.05144

1,080

2,000

Bluejay

45 / 4.00

7 / 2.66

565.5

38.9

31.98

1,870

132.7

0.05118

1,074

2,000

Curlew

54 / 3.51

7 / 3.51

522.5

67.7

31.59

1,976

161.5

0.05518

1,033

2,000

Ortolan

45 / 3.85

7 / 2.57

523.9

36.3

30.81

1,734

123.3

0.05517

1,025

2,000

Tanager

36 / 4.30

1 / 4.30

522.8

14.5

30.10

1,553

94.8

0.05488

1,021

2,000

Cardinal

54 / 3.38

7 / 3.38

484.5

62.8

30.42

1,833

149.7

0.05973

983

2,000

Rail

45 / 3.70

7 / 2.47

483.8

33.5

29.61

1,602

116.1

0.05975

975

2,000

Catbird

36 / 4.14

1 / 4.14

484.6

13.5

28.98

1,440

87.9

0.05944

971

2,000

Canary

54 / 3.28

7 / 3.28

456.3

59.1

29.52

1,726

141.0

0.06332

948

2,000

Ruddy

45 / 3.59

7 / 2.40

455.5

31.7

28.74

1,509

109.4

0.06332

940

2,000

Mallard

30 / 4.14

19 / 2.48

403.8

91.8

28.96

1,841

171.2

0.07186

886

2,000

* Note :

Ambient temperature : 35o C


wind velocity : 0.6 m/sec
Continuous operating temperature of conductor : 80C

Conductivity of Al
: 61% IACS
Solar absorbtion coefficient
: 0.5
Emissivity with respect to black body : 0.6

www.kmi.co.id

PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification

Technical Properties
Number / Diameter
of Wire

Calculated Cross
Section Area

Approx.
Weight of
Conductor

Calculated
Breaking
Load

DC
Resistance
at 20 C
Max.

Current
Carrying
Capacity *

Standard
Length
per Reel

Ohm/km

Al

GSW

Al

GSW

Approx.
Overall
Diameter

No. / mm

No. / mm

mm

mm

mm

kg/km

kN

Condor

54 / 3.08

7 / 3.08

402.3

52.2

27.72

1,522

124.3

0.07173

876

2,000

Tern

45 / 3.38

7 / 2.25

403.8

27.8

27.03

1,335

97.5

0.07168

869

2,000

Drake

26 / 4.44

7 / 3.45

402.6

65.4

28.11

1,627

139.7

0.07167

880

2,000

Cuckoo

24 / 4.62

7 / 3.08

402.3

52.2

27.72

1,522

123.8

0.07166

876

2,000

Coot

36 / 3.77

1 / 3.77

401.9

11.2

26.39

1,194

72.9

0.07134

865

2,000

Redwing

30 / 3.92

19 / 2.35

362.1

82.4

27.43

1,651

153.7

0.07987

828

2,000

Starling

26 / 4.21

7 / 3.28

361.9

59.1

26.68

1,465

125.9

0.07963

823

2,000

Stilt

24 / 4.39

7 / 2.92

363.3

46.9

26.32

1,372

113.3

0.07961

820

2,000

Gannet

26 / 4.07 7 / 3.16

338.3

54.9

25.8

1,366

117.3

0.08551

786

2,000

Flamingo

24 / 4.23

7 / 2.82

337.3

43.7

25.4

1,276

105.5

0.08546

783

2,000

Egret

30 / 3.70

19 / 2.22

322.6

73.5

25.9

1,472

140.6

0.08984

769

2,000

Scoter

30 / 3.70

7 / 3.70

322.6

75.3

25.9

1,484

135.5

0.08984

769

2,000

Grosbeak

26 / 3.97

7 / 3.09

321.8

52.5

25.2

1,302

111.9

0.08957

763

2,000

Rook

24 / 4.14

7 / 2.76

323.1

41.9

24.8

1,222

101.0

0.08960

760

2,000

Swift

36 / 3.38

1 / 3.38

323.0

9.0

23.7

960

60.7

0.08916

751

2,000

Kingbird

18 / 4.78

1 / 4.78

323.0

17.9

23.9

1,030

69.7

0.08914

754

2,000

Teal

30 / 3.61

19 / 2.16

307.1

69.6

25.2

1,398

133.4

0.09443

744

2,000

Wood Duck

30 / 3.61

7 / 3.61

307.1

71.6

25.3

1,413

129.0

0.09443

745

2,000

Squab

26 / 3.87

7 / 3.01

305.8

49.8

24.5

1,236

108.1

0.09422

739

2,000

Peacock

24 / 4.03

7 / 2.69

306.1

39.8

24.2

1,159

95.9

0.09413

736

2,000

Eagle

30 / 3.46

7 / 3.46

282.1

65.8

24.2

1,298

122.9

0.1027

706

2,000

Dove

26 / 3.72

7 / 2.89

282.6

45.9

23.6

1,142

101.1

0.1024

701

2,000

Parakeet

24 / 3.87

7 / 2.58

282.3

36.6

23.2

1,068

88.3

0.1024

698

2,000

Ospray

18 / 4.47

1 / 4.47

282.5

15.7

22.4

900

61.0

0.1019

692

2,000

Hen

30 / 3.20

7 / 3.20

241.3

56.3

22.4

1,110

105.2

0.1197

639

2,000

Hawk

26 / 3.44

7 / 2.68

241.6

39.5

21.8

978

86.7

0.1196

635

2,000

Flicker

24 / 3.58

7 / 2.39

241.6

31.4

21.5

915

76.8

0.1195

632

2,000

Pelican

18 / 4.14

1 / 4.14

242.3

13.5

20.7

772

52.3

0.1189

627

2,000

Lark

30 / 2.92

7 / 2.92

200.9

46.9

20.4

924

90.3

0.1437

569

2,000

Ibis

26 / 3.14

7 / 2.44

201.3

32.7

19.9

814

72.1

0.1435

565

2,000

Brant

24 / 3.27

7 / 2.18

201.6

26.1

19.6

762

64.7

0.1434

563

2,000

Chickadee

18 / 3.77

1 / 3.77

200.9

11.2

18.9

640

43.4

0.1427

557

2,000

Oriole

30 / 2.69

7 / 2.69

170.5

39.8

18.8

785

77.4

0.1698

511

2,000

Linnet

26 / 2.89

7 / 2.25

170.6

27.8

18.3

690

62.8

0.1696

507

2,000

Merlin

18 / 3.47

1 / 3.47

170.2

9.5

17.4

543

38.2

0.1686

501

2,000

Ostrich

26 / 2.73

7 / 2.12

152.2

24.7

17.3

615

56.6

0.1900

471

2,000

Partridge

26 / 2.57

7 / 2.00

134.9

22.0

16.3

545

50.2

0.2136

437

2,000

Waxwing

18 / 3.09

1 / 3.09

135.0

7.5

15.5

430

30.3

0.2127

432

2,000

Penguin

6 / 4.77

1 / 4.77

107.2

17.9

14.3

433

37.1

0.2666

377

2,000

Cochin

12 / 3.37

7 / 3.37

107.0

62.4

16.9

785

91.8

0.2697

393

2,000

Brahma

16 / 2.86

19 / 2.48

102.8

91.8

18.1

1,005

126.5

0.2803

394

2,000

Dorking

12 / 3.20

7 / 3.20

96.5

56.3

16.0

708

82.8

0.2986

368

2,000

Dotterel

12 / 3.08

7 / 3.08

89.4

52.2

15.4

656

76.7

0.3221

351

2,000

Pigeon

6 / 4.25

1 / 4.25

85.1

14.2

12.8

344

29.4

0.3365

325

2,000

Guinea

12 / 2.92

7 / 2.92

80.4

46.9

14.6

589

71.1

0.3583

327

2,000

Leghorn

12 / 2.69

7 / 2.69

68.2

39.8

13.5

500

60.7

0.4234

294

2,000

Quail

6 / 3.78

1 / 3.78

67.3

11.2

11.3

272

23.3

0.4243

280

2,000

Minorca

12 / 2.44

7 / 2.44

56.1

32.7

12.2

412

50.2

0.5142

260

2,000

Type

* Note :

Ambient temperature
wind velocity
Continuous operating temperature of conductor

: 35o C
: 0.6 m/sec
: 80C

Conductivity of Al : 61% IACS


Solar absorbtion coefficient : 0.5
Emissivity with respect to black body : 0.6

www.kmi.co.id

PT. KMI Wire and Cable Tbk reserves the right to change the data content without prior notification

Technical Properties
Number / Diameter
of Wire
Type

Calculated Cross
Section Area

Al

GSW

Al

GSW

Approx.
Overall
Diameter

Approx.
Weight of
Conductor

Calculated
Breaking
Load

DC
Resistance
at 20 C
Max.
Ohm/km

Current
Carrying
Capacity *

Standard
Length
per Reel

No. / mm

No. / mm

mm

mm

mm

kg/km

kN

Raven

6 / 3.37

1 / 3.37

53.5

8.9

10.1

216

19.4

0.5341

242

2,000

Patrel

12 / 2.34

7 / 2.34

51.6

30.1

11.7

379

46.2

0.5600

246

2,000

Robin

6 / 3.00

1 / 3.00

42.4

7.1

9.0

171

15.8

0.6743

208

2,000

Grouse

8 / 2.54

1 / 4.24

40.5

14.1

9.3

222

22.9

0.7089

205

2,000

Sparate

7 / 2.47

1 / 3.30

33.5

8.6

8.2

159

16.1

0.8497

181

2,000

Sparrow

6 / 2.67

1 / 2.67

33.6

5.6

8.0

136

12.7

0.8499

180

2,000

Swanate

7 / 1.96

1 / 2.61

21.1

5.4

6.5

100

10.5

1.353

135

2,000

Swan

6 / 2.12

1 / 2.12

21.2

3.5

6.4

86

8.3

1.353

134

2,000

Turkey

6 / 1.68

1 / 1.68

13.3

2.2

5.0

54

5.3

2.152

100

2,000

* Note :

Ambient temperature
wind velocity
Continuous operating temperature of conductor

: 35o C
: 0.6 m/sec
: 80C

Conductivity of Al : 61% IACS


Solar absorbtion coefficient : 0.5
Emissivity with respect to black body : 0.6

www.kmi.co.id

PT. KMI Wire and Cable Tbk reserves the right to change the data content without prior notification

You might also like