XP30-90 Hardware Manual

Download as pdf or txt
Download as pdf or txt
You are on page 1of 88

Right choice for ultimate yield

LSIS strives to maximize customers' profit in gratitude of choosing us for your


partner.

Programmable Logic Controller

XGT PANEL
XGT PANEL Series

Users Manual
XP30-BTE
XP30-BTA
XP30-TTA
XP50-TTA
XP70-TTA
XP80-TTA
XP90-TTA

z Read

this manual carefully before


installing, wiring, operating, servicing
or inspecting this equipment.

z Keep

this manual within easy reach


for quick reference.

http://eng.lsis.biz

Safety Precautions

Before using the product


To use the product safely and effectively, please read this instruction manual thoroughly before use.

Please keep to the safety precaution, for it is to prevent accidents and potential danger from occurring.

Safety precaution is classified into Warning and Caution and their meanings are as follows.

Warning

Violating the instruction may result in serious personal injury or death.

Caution

Violating the instruction may result in slight personal injury or product damage.

The indicated illustrations on the product and in the manual have the following meanings.
Be cautious, for danger may be present.
Be cautious, for there is a possibility of an electric shock.

After reading the instruction manual, keep it handy for quick reference.

Safety Precautions

Design Precautions
Warning
Install a safety circuit external to the HMI to protect the whole control system in case of
external power supply trouble.
Serious trouble may occur to the entire system due to erroneous output/operation of the HMI.

Design Precautions
Caution
In/output signal or communication cable should be at least 100mm apart from
High-voltage/power wires.
Otherwise, it may cause erroneous output/operation.

Installation Precautions

Caution
 Use the HMI in an environment that meets the general specification contained in this
manual or datasheet.
Otherwise, it could result in electric shock, fire, erroneous operation or deterioration.

 In case of much vibration in the installed environment, be sure to insulate the HMI from
direct vibration.
Otherwise, it could result in electric shock, fire or erroneous operation.

 Be sure not to let foreign substances such as conductive debris inside the product.
Otherwise, it could result in electric shock, fire or erroneous operation.

Safety Precautions

Wiring Precautions
Warning
 Be sure to turn off the HMI and external power before wiring.
Otherwise, it may result in an electric shock or damage to the product.

Caution
 Wire correctly by checking each of the products rated voltage and terminal layout.
Otherwise, it may result in fire, electric shock or erroneous operation.

 Tighten terminal screws with specified torque when wiring.


If terminal screws are loose, it may result in short circuits, fire or erroneous operation.

 Use the exclusive HMI 3-type grounding for the FG terminal.


If not grounded, it may result in erroneous operation.

 Be sure not to let any foreign substances such as wiring debris inside the module.
Such debris may cause fire, damage or erroneous operation.

Safety Precautions

Startup and Maintenance Precautions


Warning
 Do not touch the terminals while power is on.
Otherwise, it may cause electric shock or erroneous operation.

 Turn off the PLC and external power when cleaning or tightening the terminal.
Otherwise, it may cause electric shock or erroneous operation.

 Do not charge, disassemble, heat, short circuit, solder, etc. the battery.
Mishandling the battery may cause overheating, crack, fire and may result in injury or fire.

Caution
 Do not disassemble PCB from the product case or modify the product.
Otherwise, it may result in fire, electric shock or erroneous operation.

 Use cellular phone or walky-talky at least 30cm away from the PLC.
Otherwise, it may result in erroneous operation.

Disposal Precaution
Caution
 When disposing of this product or battery, treat it as industrial waste.
Otherwise, it may cause poisonous pollution or explosion.

Revision History

Revision History
Version

Date

Contents

V1.0

07.4

First Edition

V2.0

09.10

1. Initial screen changed (horizontal bar -> square box type)


2. Menu name of initial screen changed
(Download From USB -> Storage Download)
3. Selecting one project file among many project files is available
4. Sending project file by CF card is available
5. File backup function by external storage equipment added
6. Format of backup file is changed into CSV format
7. New module XP80-TTA/AC added
8. Project upload function by external storage equipment added
9. Update function by external storage equipment added
10. XP30-BTE interface added
11. Figure and name of each part for XP30-BTE added
12. Specification of XP30-BTE added
13. Aux diagnosis function added
14. Dimension of XP30-BTE added
15. Specification of XP90-TTA/AC, XP70/80-TTA/DC added
16. Dimension of XP90-TTA/AC, XP70/80-TTA/DC added
17. PLC communication setting option in device menu added
18. Multi-Touch function in environment setting added

The number of Users manual is indicated the right side of the back cover.
LS Industrial Systems Co., Ltd 2006
All Rights Reserved.

Revised location
CH4, CH5, CH6, CH8
CH7.1
CH7
CH7
CH9
CH9
CH3, CH12, APP2
CH7
CH7
CH1
CH2
CH3
CH5
APP2
CH3, CH10
APP2
CH6.7
CH4.1

Chapter. 1 General Introduction ...................................................................................... 1-1~1-6


1.1 Usage of User Manual......................................................................................................................................................1-1
1.2 Feature...............................................................................................................................................................................1-2
1.3 Terminology .......................................................................................................................................................................1-6

Chapter. 2 System Configuration....................................................................................... 2-1~2-6


2.1 Name and Function of Each Part ....................................................................................................................................2-1
2.2 System Configuration .......................................................................................................................................................2-5

Chapter. 3 Standard Specification....................................................................................3-1~3-6


3.1 General Standards............................................................................................................................................................3-1
3.2 Function Standards...........................................................................................................................................................3-2

Chapter. 4 System Configuration.....................................................................................4-1~4-6


4.1 Touch Calibration...............................................................................................................................................................4-1
4.2 Backlight Setting................................................................................................................................................................4-2
4.3 Date Time Setting..............................................................................................................................................................4-3
4.4 PC Connection Setting .....................................................................................................................................................4-3
4.5 Ethernet Setting.................................................................................................................................................................4-4
4.6 Contrast Setting (only for XP30-BTA/DC).......................................................................................................................4-5
4.7 Environment Setting..........................................................................................................................................................4-5

Chapter. 5 Diagnostics.......................................................................................................5-1~5-5
5.1 Screen Diagnosis..............................................................................................................................................................5-1
5.2 Touch Diagnosis................................................................................................................................................................5-2
5.3 Backup Memory Diagnosis..............................................................................................................................................5-2
5.4 Flash Memory Diagnosis Function..................................................................................................................................5-3
5.5 CF Card Diagnosis............................................................................................................................................................5-3
5.6 Serial Communication Diagnosis ....................................................................................................................................5-4
5.7 LED Diagnosis...................................................................................................................................................................5-5
5.8 Aux Diagnosis....................................................................................................................................................................5-5

Chapter. 6 Viewing Information of PLC Connection Status .......................................6-1~6-5


6.1 Connection Information ....................................................................................................................................................6-2
6.2 PLC Information ................................................................................................................................................................6-2
6.3 History of PLC Error ........................................................................................................................................................6-3
8

6.4 History of PLC Mode Conversion ..................................................................................................................................6-3


6.5 History of PLC Power .....................................................................................................................................................6-4
6.6 History of PLC System ...................................................................................................................................................6-4
6.7 PLC Communication Configuration Settings ................................................................................................................6-5

Chapter. 7 Storage Function .................................................................................................... 7-3


7.1 General Introduction ........................................................................................................................................................7-1
7.2 Downloading Project through the Storage Equipment ..................................................................................................7-2
7.3 Uploading Project through the Storage Equipment .......................................................................................................7-2
7.4 Updating the Device through Storage Equipment .........................................................................................................7-3

Chapter. 8 XGT Panel S/W Update .......................................................................................... 8-1


8.1 General Introduction ........................................................................................................................................................8-1

Chapter. 9 File Backup through External Storage Equipment........................................... 9-5


9.1 Path Structure in case of File Backup .............................................................................................................................9-1
9.2 Operation setting when there is no Space for Backup...................................................................................................9-3
9.3 Monitoring Connection Status of External Storage Equipment.....................................................................................9-4

Chapter. 10 Installation and Wiring............................................................................. 10-1~10-8


10.1 Installation......................................................................................................................................................................10-1
10.1.1 Installation environment.....................................................................................................................................10-1
10.1.2 Notice in handling...............................................................................................................................................10-2
10.1.3 Notice in installing the panel..............................................................................................................................10-2
10.2 Wiring .............................................................................................................................................................................10-5
10.2.1 Power wiring.......................................................................................................................................................10-5
10.2.2 Ground wiring .....................................................................................................................................................10-8

Chapter. 11 Maintenance ...............................................................................................11-1~11-3


11.1 Maintenance..................................................................................................................................................................11-1
11.2 Daily Maintenance.........................................................................................................................................................11-1
11.3 Periodical Maintenance ................................................................................................................................................11-2

Chapter. 12 EMC Standard Certification ................................................................... 12-1~12-2


12.1 Requirement for EMC Standard Certification ...........................................................................................................12-1
12.1.1 CE standard certification ..................................................................................................................................12-1
12.1.2 MIC standard certification ................................................................................................................................12-2
9

12.2 Requirement for Low Voltage Command Suitability..................................................................................................12-2


12.2.1 Standard applied for XGT Panel.......................................................................................................................12-2
12.2.2 Selection of XGT Panel ...................................................................................................................................12-2

Appendix 1. Troubleshooting ......................................................Appendix1-1~Appendix1-18


1. Type of Problem .................................................................................................................................................Appendix 1-1
2. Problem when Starting.......................................................................................................................................Appendix 1-1
3. Reaction Problem when touching.....................................................................................................................Appendix 1-2
4. Indication Problem of Figure and Object..........................................................................................................Appendix 1-2
5. Communication Problem...................................................................................................................................Appendix 1-5
6. CF/USB Removal of Memory Card..................................................................................................................Appendix 1-6
7. Error Message during Execution of Program ..................................................................................................Appendix 1-7

Appendix 2. Dimension ............................................................... Appendix 2-1~ Appendix 2-3

10

Chapter 1. General Introduction

Chapter 1. General Introduction


1.1 Usage of User Manual
This manual provides information of each products specification, usage and so on. This is necessary to use XGT Panel for medium and large
HMI system.
The user manuals configuration is as follows.
Sequence

Category

Contents

Chapter 1

General Introduction

It describes this manuals configuration, products feature and term.

Chapter 2

System Configuration

It describes feature and system configuration of each XGT Panel.

Chapter 3

Standard Specification

It describes XGT Panels general and function specification.

Chapter 4

System Configuration

It describes XGT Panels system configuration.

Chapter 5

Diagnostics

It describes XGT Panels self-diagnosis.

Viewing information of
PLC Connection Status
Transmission of Project
from USB Storage Device

It describes the way on connection status information of PLC which is


connected with XGT Panel.

Chapter 8

XGT Panel S/W Update

It describes the way to update engine at XGT Panel.

Chapter 9

Backup files by using


Storage Devices

It describes the way to backup recipe, logging and etc. files by using
storage devices.

Chapter 10

Installation and Wiring

It describes an installation, wiring and caution for reliability of PLC system.

Chapter 11

Maintenance

It describes inspection category and method for long normal operation of PLC
system.

Chapter 12

EMC Standard

It describes system configuration for EMC standard.

Appendix 1

Troubleshooting

It describes a variety of error contents and measure.

Appendix 2

Dimension

It describes the dimension of XGT Panel.

Appendix 3

Warranty and
Environment Policy

Chapter 6
Chapter 7

It describes the way to execute the project by using USB storage device.

Remark
This manual doesnt describe connection with XP-Builder and PLC. For their own function, Please refer to the related
manuals.

1-1

Chapter 1. General Introduction

1.2 Feature
XGT Panel has the following features.
(1) Diverse external interface
(a) It maximizes customs use by providing diverse external interface including USB, CF card and Ethernet.

Expansion connector

CF card

Communication
Module

Memory Interface
Logging data
Image/font data

USB host
Printer

Etc.
Tool port (RS-232C): XP-Builder

USB Storage
Device
Keyboard,
Mouse
(b) It can be connected with control device such as PLC, INVERTER.
It can be connected by RS-232C, RS-422/485, Ethernet (10/100 BASE-T).

Ethernet
XP-Builder
Inverter
Open network

1-2

Inverter

Chapter 1. General Introduction


(c) XP30-BTE, economic type, is not supported for Ethernet, expansion connector and CF card..

Battery Cover

RS232C
RS422/RS485
Terminal Block Type

USB Port

(2) Based on Windows CE


(a) Adoption of Microsoft Companys Windows CE
Windows CE 5.0
(b) Advantage
It provides stable software capacity by using Microsoft Companys platform.
It can process diverse function simultaneously.
It provides diverse interface including Ethernet, USB, CF card.
The user interface including mouse and keyboard can be connected.
It has high flexibility like computer software.
Fast reaction is available when adding new equipment.
Wide data sharing and management with upper system is available. (Later)
(3) Improvement of project transmission time
(a) It provides Ethernet which is faster than RS-232C.
Download

Upload
(b) It provides the transmission function from USB storage device.
Data change

1-3

Chapter 1. General Introduction


(4) High quality screen
(a) It provides the high quality screen and clearness by high quality LCD.
It adopts TFT LCD which supports the 65,536 colors. (XP30-BTE/DC and XP30-BTA/DC adopts STN Mono LCD.)
(b) It provides diverse graphic type.
It is available to express precisely and actually.
It provides the simple moving function with GIF support.
(5) Analog touch Panel
(a) It adopts analog (resistor film method) Touch Panel.
Visibility is improved without the grids.
(b) It provides high touch resolution.
It can control Touch Panel precisely.

(6) Multilingual and diverse font


(a) It supports the multilingual function.
It transmits the Windows/User font used in computer to XGT Panel.
Additional language development is not necessary.
Multilingual language is an advantage of Windows CE.
(b) It can express four kinds of language simultaneously.
It can express 4 kinds of language simultaneously.
Language switching is available by using special switch during operation.
(c) It can provide the various fonts.
Various expressions are available by using the Windows/User font.
Font size and type can be adjusted freely.

1-4

Chapter 1. General Introduction


(7) Advanced function
(a) Alarm function
The History alarm can be classified alarm group and alarm list and selected alarm can be expressed by alarm search.
The Flow alarm indicates current or the latest alarm at the bottom of screen.
The System alarm indicates the important problems from operation.
(b) Logging function
It provides conditional logging according to device condition and continuous periodic logging which operates periodically
according to time and device status.
It provides 255Kbyte areas for backup.
Backup into CF card or USB storage device is available.
Backup datas type is stored in Excel, it is easy to use.
(c) Recipe function
It provides READ/WRITE function.
A recipe provides Max. 100 Dwords and 16 blocks.
Backup into the CF card or USB storage device is available.
Backup datas type is stored in Excel, it is easy to use.
(d) Scheduler function
It can be set up to Max. 32.
(e) Print function
It provides a Screen/Alarm print function.
It can be printed by USB printer.
(f) Script function
It provides more flexible function by user Script.
It can be diversely applied to such as including Global/Object/Screen indication and so on.
(8) Stable product suitable for international standards
(a) CE, KCC standard acquisition
(b) UL standard acquisition

1-5

Chapter 1. General Introduction

1.3 Terminology
It describes terms used in this manual.
Term

1-6

Definition

Example

Module

A standard element that has a specified function which configures the system.
Devices such as I/O board, which inserted onto the mother board or base unit.

Ex.) CPU module


Power module,
I/O module

Unit

A single module or group of modules that perform an independent


operation as a part of PLC system.

Ex.) Basic unit,


Extension unit

PLC system

System consisted of PLC and peripheral device which can be controlled by


user program.

XP-Builder

Software used to write and edit the project.

Cnet module

Computer Link

FEnet module

Fast Ethernet Network

RTC

Abbreviation of Real Time Clock. It is used to call general IC that contains


clock function.

Chapter 2. System Configuration

Chapter 2. System Configuration


Here describes the feature of XGT Panel and system configuration.

2.1 Name and Function of Each Part


1. XP30-BTA, XP30/50/70/80-TTA

Number

Name
Front view

Description
1) Analog touch panel: User touch input
2) LCD: screen indication
Indicates operation status of device

LED Status

Green
Red

Normal RUN status


(monitoring, downloading the project data)
Initializing the status when booting
(HMI does not operate)
Error occurs
(communication error, project data error)

2-1

Chapter 2. System Configuration

Number

Name

Description

Panel fixed part

XGT Panel is fixed at panel by bracket.

CF card interface

1) Logging/recipe/screen data backup


2) Upgrade of windows CE is available.

Power connection
terminal

It consists of power input and FG terminal.

USB interface

It consists of 2 ports.
1) USB memory connection: logging/recipe/screen data backup
2) USB memory connection: project data transmission/backup
3) User interface connection: use of mouse/keyboard
4) Printer connection: printing is available

Extension port

Extension module installation

Reset switch

Hardware reset switch

TOOL interface

RS-232C interface
1) project data transmission
2) logging/recipe/alarm/screen data backup
3) machine software upgrade

Setting switch

Device setting switch


No.1

No use
A setting

Normal operation (basic setting)

B setting

When upgrading Windows CE

A setting

Use of Watchdog (basic setting)

B setting

No use of Watchdog

A setting

RS-422/485 terminal resistor setting (120)

B setting

No use of RS-422/485 terminal resistor

No.2

No.3

No.4

Extension module
fixation hall

Extension module fixation hall

RS-422/485 connector

RS-422/485: PLC/control machine communication

RS-232C connector

RS-232C: PLC/control machine communication

Ethernet terminal

Ethernet: 10/100 BASE-T


1) Project data transmission
2) logging/recipe/alarm/screen data backup
3) machine software upgrade
4) PLC/control machine communication

FG terminal

FG terminal hole for extension module

Remark
(1) For details about communication connection, please refer to the communication user manual.
(2) For details about installation, please refer to the Chapter 10

2-2

Chapter 2. System Configuration


When you use the XGT Panel, the prevention tape is installed to prevent battery discharge.
If you remove this prevention tape, backup is available.
In order to remove tape, pull tape downward like the following figure.

Prevention
tape

2. XP30-BTE

2-3

Chapter 2. System Configuration

Number

Name
Front view

Description
1) Analog touch panel: User touch input
2) LCD: screen display
Indicates operation status of module.

LED Status

Green
Red

Normal RUN status


(monitoring, downloading the project data)
Initializing mode when booting
(HMI does not Ready)
Error occurs
(communication error, project data error)

Panel fixed part

XGT Panel is fixed at panel by bracket.

Power terminal
cover

Prevention from electric shock

USB interface

Communication
interface

1) USB memory connection: logging/recipe/screen data backup


2) USB memory connection: project data transmission/backup
3) User interface connection: use of mouse/keyboard
4) Printer connection: printing is available
RS-232C, RS-422/485: For communication with controller
(PLC)

Reset switch

Hardware reset switch

Battery cover

Open or close when replacing the battery

Tool interface

RS-232C interface
1) Project data transmission
2) Logging/recipe/alarm/screen data backup
3) Machine software upgrade

Setting switch

Module setting switch


No.1

Reserved
A setting

Normal operation (basic setting)

B setting

When upgrading Windows CE

Asetting

Use of Watchdog (basic setting)

B setting

No use of Watchdog

A setting

RS-422/485 terminal resistor setting (120)

B setting

No use of RS-422/485 terminal resistor

No.2

No.3

No.4

2-4

Power terminal

It consists of power input and FG terminal

Chapter 2. System Configuration

2.2 System Configuration


In order to use XGT Panel, write project data at the XP-Builder and transmit it to the XGT Panel.
XGT Panel can be basically connected through RS-232C.
Maximum communication speed is 115,200 [bps].

RS-232C communication speed is not fast so it takes long time to transmit project data into XGT Panel.
Project data can be quickly transmitted through Ethernet.
When LAN system is configured like the following figure, you can use it easily and effectively.

LAN

In case that LAN system is not configured, it provides 1:1 connection. (LAN cable should be cross cable.)

Ethernet

2-5

Chapter 2. System Configuration


When communication is not available to transmit project data, USB storage device is available
For details, please refer to the Chapter.7 and XP-Builder user manual.

Remark
1) We recommend Ethernet more than RS-232C.
2) For the Ethernet cable manufacture, please refer to the communication manual.
3) For the project transmission method, please refer to the XP-Builder manual.
4) Ethernet is not supported on XP30-BTE

2-6

Chapter 3. Standard Specification

Chapter 3. Standard Specification


3.1 General Standards
XGT Panels general standard is as follows.
No.

Category

Standard

Related standard

Ambient
operating
temperature

0+50

Storage
temperature

-20+60

Operating
humidity

1085%RH, non-condensing.

Storage
humidity

1085%RH, non-condensing.
Occasional vibration

Vibration
resistance

count

Frequency

Acceleration

Amplitude

5 f < 9

3.5 mm

9 f 150

9.8

10 times for each

Continuous vibration

Shock
endurance

Noise Immunity

X, Y, Z axis

Frequency

Acceleration

Amplitude

5 f < 9

1.75 mm

9 f 150

4.9

IEC 61131-2

* Maximum shock acceleration: 147 (15g)


IEC 61131-2

* Duration time: 11
* Pulse wave: half sine pulse (3 shocks per axis, on X, Y, Z axis)

LSIS

Square wave
Impulse noise

AC: 1,500V
DC: 1,000V

Electrostatic
discharge Immunity

Voltage: 6 kV (Discharge by contact)

IEC 61131-2
IEC 61000-4-2

Radiated
electromagnetic
field noise

27 ~ 500 MHz, 10 V/m

IEC 61131-2
IEC 61000-4-3

Fast transient &


Burst noise

Category

Power module

Voltage

2 kV

Standard

Communication interface IEC 61131-2

Atmosphere

Free from corrosive gases and excessive dust

Altitude

Less than 2,000m (6,562 ft)

10

Pollution degree

Less than 2

11

Cooling method

Air-cooling

1 kV

IEC 61000-4-4

3-1

Chapter 3. Standard Specification

Remark
(1) IEC(International Electrotechnical Commission)
: International private group facilitating international cooperation of electric/electronic standardization, issuing international
standards and operating the compliance evaluation systems.
(2) Pollution degree
: As an index representing the pollution degree of an environment to determine the insulation of a device, pollution degree 2
generally means the status generating non-conductive contamination. However, it also contains the status generating
temporarily conduction due to condensation.
(3) Radiated electromagnetic field noise for XP30-BTE is 80 ~ 1000MHz, 10 V/m (All others are same as shown on the table)

3.2 Function Standards


XGT Panels function standard is as follows.
1. DC type
(1) Medium Series
Item
Display type

XP30-TTA/DC

STN mono LCD

TFT Color LCD

Screen size

14 (5.7)

Display Resolution

320 x 240 pixel

Color indication

8 step Gray Scale

65,000 Color

Indication degree

Left/Right: 45 deg.
Upper: 40 deg.
Lower: 20 deg

Backlight

LED Type CCFL (concluding LCD)

Left/Right: 70 deg.
Upper: 50 deg.
Lower: 70 deg.
CCFL (concluding LCD),
Supporting automatic On/Off

Backlight duration

50,000 hr.

60,000

Contrast

Adjust through touch/parameter

Brightness

230cd/

400cd/

Touch panel

4 Line type, analog

Sound Output

Magnetic buzzer

Process

ARM920T (32bit RISC), 200MHz

Graphic accelerator

Hardware Accelerator

Memory
3-2

Medium series
XP30-BTA/DC

XP30-BTE/DC

Flash
Operating RAM
Backup RAM

16MB
32MB
128KB

32MB
64MB
512KB

Backup data

Date/Hour data and Logging/Alarm/Recipe data

Battery duration

Approx. 3 years (Operating ambient temperature of 25)

Ethernet

USB Host

1 Channel

RS-232C

Terminal Block

1 Channel, IEEE802.3, 10/100Base-TX


2 Channels, USB 2.0
(printer, USB memory stick driver is available)
2 Channels

Chapter 3. Standard Specification

Item
RS-422/485
CF Card
Expansion module

XP30-BTE/DC
Terminal Block
-

Medium series
XP30-BTA/DC
XP30-TTA/DC
1 Channel,RS-422/485 mode
1 Slot (Compact Flash)
Option module is available

Multi-language

Up to 4 language simultaneously

Animation

GIF format is available

Recipe

available

Data logging

available

Script executor

available

Certifications

CE, UL, KCC

Protection standard

IP65F

Dimension (mm)
Panel cut (mm)

181 x 140 x 56.5


156 x 123.5

Rated voltage

181 x 140 x 66.5


156 x 123.5
DC24V (Actual Range: 19.2 ~ 28.8V)

Power consumption (W)

8.5

Weight(Kg)

0.62

0.75

(2) Large Series


Item

Large Series
XP70-TTA/DC

XP50-TTA/DC

Display type
Screen size

TFT Color LCD


21 (8.4)

Display Resolution

26 (10.4)

31(12.1)

640 x 480 pixel

Color indication
Indication degree

XP80-TTA/DC

800 x 600 pixel


65,000 Color

Left/Right: 65 deg.
Upper: 50 deg.
Lower: 60 deg.

Left/Right: 65 deg.
Upper: 45 deg.
Lower: 65 deg.

Left/Right: 65 deg.
Upper: 45 deg.
Lower: 75 deg.

Backlight

CCFL (Replacement is available), Supporting automatic On/Off

Backlight duration

50,000 hr.

Brightness

480cd/

430cd/
8 Line, analog

Sound Output

Magnetic buzzer

Process

ARM920T (32bit RISC), 200MHz

Graphic accelerator

Hardware Accelerator

Memory

Touch panel

Flash
Operating RAM
Backup RAM

400cd/

32MB
64MB
512KB

Backup data

Date/Hour data and Logging/Alarm/Recipe data

Battery duration

Approx. 3 years (Operating ambient temperature of 25)

Ethernet

1 Channel, IEEE802.3, 10/100Base-TX


3-3

Chapter 3. Standard Specification

Item

XP50-TTA/DC

Large Series
XP70-TTA/DC

XP80-TTA/DC

USB Host

2 Channels, USB 2.0 (printer, USB memory stick driver is available)

RS-232C

2 Channels

RS-422/485

1 Channel, RS-422/485 mode

CF Card

1 Slot (Compact Flash)

Expansion module

Option module is available

Multi-language

Up to 4 language simultaneously

Animation

GIF format is available

Recipe

available

Data logging

available

Script executor

available

Certifications

CE, UL, KCC

Protection standard
Dimension (mm)
Panel cut (mm)

IP65F
240 x 174 x 73
228.5 x 158.5

Rated voltage

317 x 243 x 73
294.5 x 227.5
DC24V (Actual Range: 19.2 ~ 28.8V)

Power consumption (W)

20

27

30

Weight(Kg)

1.4

2.2

2.4

Remark
(1) Notice in connecting with power
: Connecting AC power to the device using DC power may cause product break or fire. Be careful when connecting
(2) FG connection
: Use FG terminal (Chapter 2.1) for FG of the device. FG (Chapter 2.1) is for FG terminal of extension card.
(Except XP30-BTE)
(3) Prevention tape of Battery discharge
: There is prevention tape is to prevent the battery discharge. In order to use backup, remove the prevention tape.
(4) Battery operation and duration
: Battery is used to reserve backup data and RTC (data/time) when power is off.
Because battery is used when power is off, battery is not consumed when power is on.
(5) LCD Backlight replacement
: In XP50-TTA/DC, XP70-TTA/DC, XP80-TTA/DC, LCD backlight is replaceable.
However in XP30-BTE/DC, XP30-BTA/DC and XP30-TTA/DC, LCD backlight is not replaceable because
LCD and backlight is all-in-one type.

3-4

Chapter 3. Standard Specification

AC Type
Item

Large Series
XP80-TTA/AC

XP70-TTA/AC

Display type

XP90-TTA/AC

TFT Color LCD

Screen size

26cm (10.4)

31cm (12.1)

38cm (15)

Display Resolution

640 x 480 pixel

800 x 600 pixel

1024 x 768 pixel

Color indication
Indication degree
Backlight
Backlight Duration
Contrast
Brightness

65,000 Color
Left/Right: 65 deg.
Left/Right: 65 deg.
Left/Right: 75 deg
Upper : 45 deg.
Upper : 45 deg.
Upper : 50 deg
Lower : 65 deg.
Lower : 75 deg.
Lower : 60 deg
CCFL (Replacement is available), Supporting automatic On/Off
50,000 hr.
430cd/
400cd/
450cd/

Touch Panel

8 Line, analog

Sound Output

Magnetic buzzer

Process

ARM920T (32bit RISC), 200MHz

Graphic Accelerator
Flash
Operating Ram
Backup Ram

Hardware Accelerator
32MB
64MB

Memory

2.

64MB
128MB
512KB

Backup data

Date/Hour data and Logging/Alarm/Recipe data

Battery duration

Approx. 3 years (Operating ambient temperature of 25)

Ethernet

1Channel, IEEE802.3, 10/100Base-TX

USB Host
RS-232C
RS-422/485
CF Card
Expansion Module
Multi-language
Animation
Recipe
Data logging

2 Channels, USB 2.0 (printer, USB memory stick driver is available)


2 Channels
1 Channel,RS-422/485 mode
1 Slot (Compact Flash)
Option module is available
Up to 4 language simultaneously
GIF format is available
available
available

Script executor

available

Certification
Protection standard
Dimension (mm)
Panel cut (mm)
Rated voltage
Power consumption (W)
Weight (Kg)

CE, UL, KCC


IP65F
317 x 243 x 73
294.5 x 227.5
37
2.2

395 x 294 x 73
383.5 x 282.5
AC100~240V
40
2.4

46
3.9

3-5

Chapter 3. Standard Specification


Remark
(1) Notice in connecting with power
: If you connect DC power to the device using AC power, the product doesnt work. Please be careful when connecting.
(2) FG connection
: Use FG terminal (Chapter 2.1) for FG of the device. FG (Chapter 2.1) is for FG terminal of extension card.
(Except XP30-BTE)
(3) Prevention tape of Battery discharge
: There is prevention tape is to prevent the battery discharge. In order to use backup, remove the prevention tape.
(4) Battery operation and duration
: Battery is used to reserve backup data and RTC (data/time) when power is off.
Because battery is used when power is off, battery is not consumed when power is on.
(5) LCD Backlight replacement
: In XP70-TTA/AC, XP80-TTA/AC, XP90-TTA/AC, LCD backlight is replaceable.

3-6

Chapter 4. System Configuration

Chapter 4. System Configuration


It describes the system configuration including XGT Panels time setting, Ethernet connection setting, connection with
PC and backlight.
If you press [Settings] button in XGT Panels basic screen, you can set XGT Panels environment as follows.

XGT Panels basic screen

XGT Panels System Configuration screen

4.1 Touch Calibration


When the location is not recognized in XGT Panel, Touchs scale can be adjusted in XGT Panel. If you press [Touch Calibration] button in
System Configuration, the setting screen shows up. If you press five + marks, XGT Panels touch location adjustment is completed.

4-1

Chapter 4. System Configuration


If you press two points simultaneously while [Allow Multi-touch] is selected, XGT Panel recognizes as if middle point between two points is
selected. If you press two points simultaneously while [Allow Multi-touch] is not selected, XGT Panel recognizes as if any point is not
selected.
Remark
(1) XGT Panels Touch Calibration setting is basically set. If Touch location error is big, adjusting menu with touch can be
hard through touch. In that case, You can select the Touch Calibration setting menu by USB mouse.
(2) When touch location changes in using, redo touch setting.
(3) If you dont allow Multi-touch, sensitivity is lower than when allowing Multi-touch.

4.2 Backlight Setting


If you press [Backlight Setting] button in [System Configuration] screen as follows, setting screen shows up.

Against no use for long time through XGT Panel, you can set Automatically turn off backlight function.
Set whether you use backlight automation On/Off function or not and time, then press OK button as follows.

As above, if you input 30, the backlight automatically turns off after 30 minute later. In off status, if you touch the panel, the backlight turns on.

4-2

Chapter 4. System Configuration

4.3 Date Time Setting


If you press [DateTime Setting] button in [System Configuration] as follows, you can set XGT Panels data and time.

Remark
You can set data/time at device information of communication dialog at the XP-Builder.
For details, please refer to the XP-Builders manual.

4.4 PC Connection Setting


If you press [PC Conn Setting] button in [System Configuration] screen as follows, you can set RS-232C and TCP/IPs port number to
communicate with PC.

Remark
The condition is set as the above. No other setting is required. But in case of changing RS-232Cs communication speed, change
as above.

4-3

Chapter 4. System Configuration

4.5 Ethernet Setting


If you press [Ethernet Setting] button in [System Configuration] screen as follows, you can change IP to use Ethernet.

You can change IP address by pressing [Set] button of each IP address, Subnet Mask and Gateway. By pressing OK button, changed IP
information is reserved.

Remark
We recommend the following method, when connecting with PC solely.
1) XGT Panel setting
- IP Address : 192.168.0.10
- Subnet Mask: 255.255.255.0
- Gateway
: 192.168.0.1

2) PC setting
- IP Address : 192.168.0.11
- Subnet Mask: 255.255.255.0
- Gateway
: 192.168.0.1

Ethernet is not supported on XP30-BTE


If you reboot after pressing [Disable] button, the device will not use Ethernet. In this case, booting speed gets faster. If you use
Ethernet again, reboot after pressing [Enable].
[

4-4

Chapter 4. System Configuration

4.6 Contrast Setting (only for XP30-BTA(BTE)/DC)


If you press [Contrast Setting] button on [System Configuration] screen, you can adjust mono LCDs Contrast.

UP button increase Contrast, DOWN button decrease Contrast. Contrast value is between 0~100.
Adjustment is only available for mono type XP30-BTA.(BTE)
Adjustment is available during operation.
If you press the screen for 3 second,
shows up. You can adjust contrast by pressing
button.

4.7 Environment Setting


If you press [Environment Setting] button in [System Configuration] screen as follows, you can set Auto Goto Screen and Buzzer On/Off.

When setting [Auto Goto Screen], XGT Panel is rebooted. Or when downloading the edit data is completed, the screen automatically shows
up. If you cancel this setting, the user should press Start button in order to move to the screen.
If you select [Quick Start], when starting screen, screen shows promptly without showing progress bar because it doesnt caching the image
in advance. However, if you select this option, first screen shows slowly. Especially, if there are many animation object in screen, it may takes
several seconds based on image. But fast screen switching is available since second screen switching.
If you select [Hide Mouse Cursor], mouse cursor doesnt show after screen switching
You can set whether you use buzzer through [Buzzer On/Off] button.

4-5

Chapter 4. System Configuration


If you setting [Disable menu Bar], the menu bar basically provided to go out from monitoring screen to the waiting screen doesnt show. In
this case, if you want to go out to the waiting screen, you have to use the special switch to close the monitoring screen.
If you select the image through [Set Background Image], background image of waiting screen is set as the selected image. If you want to
cancel, press [Delete Background Image]
Remark
The buzzer can be set at the machine information tap of communication conversation box.
Please refer to the XP-Builders manual.

4-6

Chapter 5. Diagnostics

Chapter 5. Diagnostics
It describes the diagnosis function for XGT Panels communication terminal, screen and touch function.
If you press [Diagnostics] button on the XGT Panels basic screen, the menu for diagnosis shows up.

XGT Panels environment setting screen

XGT Panels basic screen

5.1 Screen Diagnosis


If you press [Screen] button, screens continuously change into diverse color with buzzer. For XP30-BTA/DC product, screen changes into 8
steps light. After all screen for diagnosis pass. Then, Close button shows up with white ground.
If you press Close button, the initial screen shows up.

Screen when XGT Panels screen diagnosis

XGT Panels XGT Panel diagnosis screen

Item

Display

XP30-BTE/DC

XP30-BTA/DC

BLACK > 8 steps gray scale


screen > WHITE

XP30-TTA/DC

XP50-TTA/DC

XP70-TTA/AC(DC)

XP80-TTA/AC(DC)

XP90-TTA/AC

RED > GREEN > BLUE > BLACK > WHITE

5-1

Chapter 5. Diagnostics

5.2 Touch Diagnosis


If you touch the screen, the touched location is displayed as follows. If pressing the [OK] button, you can quit the screen.

If the touched location is not correct, reset the Touch setting. For detailed information, please refer to the Chapter 4. System Configuration.

5.3 Backup Memory Diagnosis


If you press [Backup Memory] button, you can see the result of diagnosis in the result windows.

Remark
(1) If NVRAM Data Access Fail error is occurred, please contact with customer service center.
(2) If BATTERY STATUS BAD error is occurred, battery should be changed. Please contact with Customer service
center.

5-2

Chapter 5. Diagnostics

5.4 Flash Memory Diagnosis Function


If you press [NOR Flash] button, you can see the result of diagnosis in the result widows.

Remark
If Read Disk Information Error! occurs, please contact with Customer service center.

5.5 CF Card Diagnosis


If you press [CF Card] button, the result of diagnosis shows up in the result windows.

Remark
If Read Disk Information Error! occurs, please contact with Customer service center.
CF Card is not supported on XP30-BTE.

5-3

Chapter 5. Diagnostics

5.6 Serial Communication Diagnosis


If you press [Serial] button, you can diagnose Serial ports which is equipped at XGT Panel.
(In case of diagnosis purpose, you have to connect the loop-back terminal at each port.)

The followed feature is Loop Back terminal. In case of communication diagnosis, connect as followed feature.
The tool port terminal should be made as follows. (Connect the No.2 and 6 pin)

The RS-232C port terminal should be made as follows. (Connect the No.2 and 3 pin)

5-4

Chapter 5. Diagnostics

The RS-422/485 port terminal should be made as follows. (Connect the Pin No.4 with 8 and Pin No. 5 with 9)

5.7 LED Diagnosis


If you press [LED] button, you can check whether LED is converted into designated color or not at the bottom of XGT Panel.

5.8 AUX Diagnosis


If you press [Aux Interface] button, you can check the functions of card that is currently connected.
(Not supported on XP30-BTE)

5-5

Ch.6 Viewing Information of PLC Connection Status

Chapter 6. Viewing Information of PLC Connection Status


You can see the diverse information including XGT Panels and PLCs CPU information through View PLC Connection Status Information.

[Method]
(a) Select [PLC Information] in the menu.
(b) Select the designated PLC. The listed PLC is the same as connection number which is set at [Common - Project Property Setting
PLC/Device settings] in XP-Builder.

(c) Press [SHOW INFO]


(d) You can check the connection information of XGT Panel, information of PLC CPU, history of error, mode conversion, PLC power cut
and system.
Remark
You can check the status of PLC connection after project data is transmitted into XGT Panel.

6-1

Ch.6 Viewing Information of PLC Connection Status

6.1 Connection Information


You can check the setting items for the connection with PLC such as Vender of PLC, Target device, Connection type, Connection
information and Timeout value in the XP-Builder.

6.2 PLC Information


You can check CPU type of PLC, operation mode, state, version, and scan time.

Remark
The following PLC is available for view of PLC information.
- MASTER-K CPU, FEnet, Cnet
- GLOFA-GM CPU, FEnet, Cnet
- XGK/XGB/XGI CPU, FEnet, Cnet

6-2

Ch.6 Viewing Information of PLC Connection Status

6.3 History of PLC Error


You can check the PLC Error History.

Remark
The following PLC is available for viewing Error History.
- MASTER-K CPU doesnt have the Error History.
- GLOFA-GM CPU
- XGK/XGI CPU
- XGB CPU doesnt have the Error History.

6.4 History of PLC Mode Conversion


You can check the history about our PLCs RUN/STOP operation mode.

Remark
The following PLC is available for viewing PLC operation mode conversion history.
- MASTER-K CPU doesnt have the history about operation mode conversion.
- GLOFA-GM CPU
- XGK/XGI CPU
- XGB CPU doesnt have the history about operation mode conversion.
6-3

Ch.6 Viewing Information of PLC Connection Status

6.5 History of PLC Power

You can check the history about when PLC was turned on and off

Remark
The following PLC is available for viewing the history of when our PLC was turned off and on.
- MASTER-K CPU doesnt have the history about when our PLC was turned on and off.
- GLOFA-GM CPU
- XGK/XGI CPU
- XGB CPU doesnt have the history about when our PLC was turned on and off.

6.6 History of PLC System


You can check history about PLC system.

Remark
The following PLC is available for viewing history about system..
- MASTER-K CPU doesnt have the history about system.
- Only GLOFA-GM CPU (GM4C) has the history about system. Other CPUs dont have the history about system.
- XGK/XGI CPU
- XGB CPU doesnt have the history about system.

6-4

Ch.6 Viewing Information of PLC Connection Status

6.7 PLC Communication Configuration Settings


You can select [Settings] button to change PLC communication settings

Remark
-

For further information about the settings, please refer to the PLC user manual.
[Program Monitor] button is activated in case of LSIS PLC Direct Driver

6-5

Chapter 7. Storage Function

Chapter 7. Storage Function


7.1 General Introduction
Downloading the user project made in XP-Builder from PC, uploading the project stored in the device to PC, updating the device and
etc are available through connection with XGT Panel with Serial cable or Ethernet cable generally. However, when those connections
are not available, you can use CF card, USB storage equipment

1. If you touch [Storage Function], the following dialog box shows.

2. In case of downloading the project by using CF card or USB storage equipment, touch [Project Download] button.
3. In case of transmitting the project data stored in the device to CF card or USB storage equipment, touch [Project Upload] button.
4. In case of updating the XGT Panel with XGT Panel Software stored in CF card or USB Storage equipment, touch [XGTPanel
Update]

7-1

Chapter.7 Storage Function

7.2 Downloading Project through the Storage Equipment


1. If you touch [Project Download], the following dialog shows.

2. In case of selecting [USB], the directory list under the path, \USB Storage\XP_Project\ shows. In case of selecting [CF], the
directory list under the path, \Storage Card\XP_Project\ shows. In case of downloading the project by using storage equipment,
the project should be saved in the one lower directory between those two directories.
3. Select one among directory lists and touch [OK]. Then downloading will start.

7.3 Uploading Project through the Storage Equipment


1. If you touch [Project Upload], the following dialog shows.

2. In case of selecting [USB], the path, \USB Storage\XP_Backup\, shows. In case of selecting [CF], the path, \Storage
Card\XP_Backup\, shows. Select one between two.
3. If you touch [OK] button, project backup file is transmitted to the selected path.
4. The project backup file is saved when Download project backup file is selected when downloading the project.
If you dont select, project backup file is not saved in the device and transmission to the storage equipment is not available.

7-2

Chapter 7. Storage Function

7.4 Updating the Device through Storage Equipment


1. If you touch [Project Upload], the following dialog shows.

2. In case of selecting [USB], the directory list under the path, \USB Storage\XP_Project\ shows. In case of selecting [CF], the
directory list under the path, \Storage Card\XP_Project\ shows. In case of updating the device by using storage equipment, the
XGTPanel Softwareproject should be saved in the one lower directory between those two directories.
3. If you touch [OK] button, the device is updated with XGTPanel Software in the designated path.

Notice
(1) Do not remove USB storage equipment or turn off the device during operation. It may cause abnormal installation of
project data.
(2) Do not remove or move the directory except CF or USB storage equipment. It may cause abnormal operation.

7-3

Chapter 8. XGT Panel S/W Update

Chapter 8. XGT Panel S/W Update


8.1 General Introduction
It describes the function for updating the XGT Panel software.
New function is added to XGT software, you need to update a version of XGT .
Please refer to the following.
[Method]
Select [Upgrade -> Update XGT Panel] on the XGT Panels main screen. Then XGT Panel becomes update mode. In order to
return to the main screen, touch a screen for 3 seconds.

After downloading XGT Panel software from LSIS website, make a temporary folder and save it.
Designate the folder where the software will be saved in the XP-Builders [XGT Panel Update] windows and update XGT Panel by
[Send] menu. For more detailed information about XP-Builder, please refer to the XP-Builder user manual.

Remark
Do not remove communication cable or turn off the device during updating. It may cause the malfunction.

8-1

Chapter 9. File Backup through External Storage Equipment

Chapter 9 File Backup through External Storage Equipment


Describes on management function about external storage equipment saving backup data of logging, recipe, and screen image
(1) XGT Panel can backup the logging, recipe, and screen image data at CF card or USB storage equipment according to setting in XPBuilder.
(2) In case there is no space for backup in the designated storage equipment, it continues backup deleting previous data or stops backup
according to setting in XP-Builder
(3) Monitors attachment status of backup equipment at XP-Builder.

9.1 Path Structure in case of File Backup


Backup path structure of logging, recipe, and screen image is as follows.
Root directory of CF or USB storage equipment
Logging
1 (Logging Number)
YYYY.MM.BeginDay.EndDay.0
DD.BeginHour.EndHour.0 (space for one folder is full)
DD.BeginHour.EndHour.1 (There is free space for one folder)
DD.BeginHour. FF (There is free space for one folder)
HH.BeginMinute.FF
Lhhmmss0.CSV
2 (same as lower structure 1)
Recipe
Rhhmmss0.CSV (same as lower structure of each logging number)
ScreenImage
Shhmmss0.BMP (same as lower structure of each logging number)

1. Path structure in case of logging backup


(1) Directory named Logging is created under the root directory of USB/CF storage equipment
(2) The directory whose name is logging number is created under Logging directory.
(3) The directory whose name is year, month is created under Logging number directory.
(a) Includes day directory under
(b) Up to 500 day directories can be created.
(c) Name of year, month directory includes the firstly created day information under its directory

9-1

Chapter 9. File Backup through External Storage Equipment


Ex) In case directory is created in 2010, October and includes directory since 15th under, directorys name is
: 2010.10.15.FF
FF at end means the directory can save more data created in 2010, October (currently, the number of lower directory is 500
or less)
(d) In case month is changed, changes directory name to day information of last created day directory.
Ex) In case month becomes November from October and directory from 15th directory to 30th have been created in 2010, October
directory.
: 2010.10.15.30.0
(e) Though month is not changed, in case the number of day directory under year, month directory is 500 or above, directory name is
changed into name including day information of last created day directory.
th
Ex) In case the number of directory from first to 15 is 500 or above in the directory created in 2010, October.
: 2010.10.01.15.0
(f) In case there is the year, month directory having same start day and end day when changing directorys name due to over 500 day
directories or change of month, last digit index number increases.
Ex) In case there are three year, month directories that are having over 500 day directories created in October first and 2010 year
October directory
: 2010.10.01.01.0
: 2010.10.01.01.1
: 2010.10.01.01.2
(4) Day directory is created under year, month directory
(a) Hour directory is created under day directory
(b) Day directory can have up to 500 hour directory
(c) Name of day directory includes not day information but also hour information of first created hour directory
(d) Relation between day directory and hour directory is same as relation between year month directory and day directory.
(5) Directory whose name includes hour information is created under day directory.
(a) Hour directory includes backup file under
(b) Hour directory can include up to 500 backup file
(c) Name of hour directory include not only hour information but also minute information of first created file under
(d) Relation between hour directory and backup file is same as relation between year, month directory and day directory.
(6) Name of logging backup file includes the created hour, minute, second information.
(a) Backup file is created in CSV format.
(b) File name start with L meaning logging and includes hour, minute, second, index information
(c) In case backup file is created at the same time in terms of second, index information at the end of file name increases.
2. Path structure in case of recipe backup
(1) Directory named Recipe is created under USB/CF storage equipment root directory.
(2) Year, month directory is created under Recipe directory
(3) The lower directory structure is same as that of logging backup path structure.
(4) Name of recipe backup file includes the created hour, minute, second information.
(a) Backup file is created in CSV format.
(b) File name start with R indicating recipe and includes hour, minute, second, index information.
(c) In case backup file is created at the same time in terms of second, index information at the end of file name increases.
3. Path structure in case of screen backup
(1) Directory named Screen Image is created under USB/CF storage equipment root directory.
(2) Directory whose name is year, month is created under Screen Image directory.
(3) The lower directory structure is same as that of logging.
(4) Name of screen image backup file includes hour, minute, second information.
(a) Backup file is created in bitmap format.
(b) File name starts with S and includes hour, minute, second, index information.
9-2

Chapter 9. File Backup through External Storage Equipment


(c) In case backup file is created at the same time in terms of second, index information at the end of file name increases.
Remark
(1) When changing device time, in case of changing current time into after time, we guarantee the normal operation. But in
case of changing current time into early time, we dont guarantee the normal operation. In this case, you have to delete
directory including the changed hour and its lower directory for normal operation. For example, if you change time from
December 10th to December 5th, you have to delete year, month directory created in December 10th and restart the device
(2) Sorting by project is not supported for each logging, recipe, screen image. For example, there are no.1, 2, 3 logging
groups in the project A. And in case each logging group backups the file, 1, 2, 3 directories are created and each data is
saved under each directory. Then, in case file backup occurs in the project B having no.1, 2 logging group, backup file is
created in same directory of project A. In this case, you have to sort the backup files of project A and B based on the
created time.

9.2 Operation setting when there is no Space for Backup


You can designate in the XP-Builder whether to cancel the backup or delete the oldest backup file and execute backup when there is no
space in the storage equipment.
[Project Property Setting -> Storage Settings -> Backup Storage -> Delete old file if disk full]
1. In case of backup, deleting the oldest data
(1) In case there is no space for backup, searches the oldest year, month directory under Logging, Recipe, ScreenImage. (But in case
of Logging, finds under Logging number directory. That is, when executing backup about Logging number 2, in case there is no
backup data in Logging number 2 directory and there is data only in logging number 1, data of logging number 1 is not
searched/deleted.)
(2) Searches the oldest day directory under the oldest year, month directory.
(3) Searches the oldest hour directory under the oldest day directory.
(4) Deletes the oldest backup file under the oldest hour directory
(5) Checks the space and if more space is necessary, the above steps of (1) ~ (4) are repeated and checks the space.
(6) When deleting file, in case all data in hour directory are deleted, relevant hour directory is deleted.
(7) When deleting hour directory, in case all hour directories in day directory are deleted, relevant hour directory is deleted.
(8) When deleting day directory, in case all day directories in year, month directory are deleted, relevant year, month directory is deleted.
Remark
(1) In unknown directory or file (user file or directory), searches the oldest thing among normal backup files except unknown
directory or file.
(2) In case there is nothing except user data in now searched directory, backup operation fails. XGT Panel cant delete user
data, at this point, operation stops.

9-3

Chapter 9. File Backup through External Storage Equipment

9.3 Monitoring Connection Status of External Storage Equipment


XGT Panels monitors connection status about external storage equipment designated when setting backup path in XP-Builder.
The following figure is backup path specified in XP-Builder.

In order to use this monitoring function, you have to set about system alarm window

9-4

Chapter 9. File Backup through External Storage Equipment

In case USB storage equipment (or CF storage equipment) is removed during operation after setting the path for saving Logging backup
file as USB storage equipment (or CF storage equipment) and downloading the project into device, the designated system alarm
(HS951.0) is set. In case storage equipment is equipped again, alarm is reset.
In case USB storage equipment (or CF storage equipment) is removed during operation after setting the path for saving Recipe backup
file as USB storage equipment (or CF storage equipment) and downloading the project into device, the designated system alarm
(HS951.1) is set. In case storage equipment is equipped again, alarm is reset.
In case USB storage equipment (or CF storage equipment) is removed during operation after setting the path for saving ScreenImage
backup file as USB storage equipment (or CF storage equipment) and downloading the project into device, the designated system alarm
(HS951.2) is set. In case storage equipment is equipped again, alarm is reset.
Internal address of the designated system alarm can be checked in XP-Builder as follows.

9-5

Chapter 10. Installation and Wiring

Chapter 10. Installation and Wiring


10.1 Installation
10.1.1 Installation environment
This machine has high reliability regardless environment. But for reliability and stability, be careful the followings

(1) Environment condition


(a) Install at the panel which can protect this machine from water and dust.
XGT Panel is designed by IP65 Standard in front parts and IP20 Standard in rear parts.
(b) Install at the place where impact and vibration is not continuously applied.
XGT Panel is designed to meet IEC standard (IEC 61131-2).
(c) Do not expose this machine to direct light.
(d) Do not install at the place where rapid temperature change can occur.
Moisture by rapid temperature change can cause malfunction and damage.
(e) This machine should be installed within 0 ~ 50C, otherwise the screen may be changed or cause malfunction
(f) This machine should be installed within 10~85% relative-humidity.
Moisture by rapid temperature change can cause malfunction and damage.
(g) Avoid corrosive gas and burnable gas.

(2) Installation construction


(a) When doing screws processing or wiring construction, be careful that the remains do not enter the XGT Panel inside.
(b) Install at the place where you can easily control.
(c) Do not install with high voltage machine within same Panel.
(d) Keep distance of more than 100mm from duct for wiring and peripheral machine.
(e) Ground at the place where few noises develops.

(3) Anti-heat design of control panel


(a) In case of installing XGT Panel in the airtight panel, consider the heat by other machine as well as own heat. In case that the air
circulates through a ventilating opening or a general pan, XGT Panel system can be influenced by in-draft of dust or gas.
(b) We recommend you to install a filter or to use an airtight heat exchanger.

Remark
Anti-water and anti-vibration standard
IP standard is IEC 529 standard (international anti-water grade regulation) and it can be divided into protection grade against
invasion of solid matter and protection grade against invasion of water.
In the IP65 certification, it can be divided into protection against dust (6) and water jets from all sides (5).
IP20 is about protection against solid matter (2) whose diameter is more than 12mm and IP2 doesnt have protection about water
(0))

10-1

Chapter 10. Installation and Wiring


10.1.2 Notice in handling
It describes the notice from opening to installation.
Do not drop or cause heavy impact.
Do not disassemble voluntarily. When doing this, we are not responsible for the product.
When wiring, be careful that the remains do not enter into XGT Panel.

10.1.3 Notice in installing the panel


Here describes how to install XGT Panel in panel and notice.

(1) Panel cut


Before installing the XGT Panel in panel, panel should be made with the following dimension.

Classification
XP30-BTE
XP30-BTA
XP30-TTA

X (Wide)
1
156.0

XP50-TTA

228.5

XP70-TTA

294.5

XP80-TTA

294.5
383.5

XP90-TTA

0
1
0
1
0
+1
-0
1
0

Y (Height)
1
123.5
0
158.5
227.5
227.5
282.5

1.6~9.5

+1
-0
1
0

10-2

1
0
1
0

Unit: [mm]
Z (Thickness)

Chapter 10. Installation and Wiring

(2) Panel installation


Keep the distance of 100 mm between XGT Panel and panel per each direction.
Unit: [mm]

100

100

100

100

100

Remark
(1) To be affected at a minimum by the electromagnetic waves (radial noise) or heat from other controllers, it needs to keep its
distance as the above explanation.
(2) When installing, consider the power and communication cable wiring.
When fixing the product to panel, use the anti-vibration rubber packing.
The anti-vibration rubber packing is equipped at the XGT Panel basically.

Anti-vibration
rubber packing

Remark
Because the product can be affected by dust, use the anti-vibration rubber packing.
10-3

Chapter 10. Installation and Wiring

(3) Installation location


When installing the XGT Panel, consider screen and use of touch.
When you dont see within the following angle, you may not see clearly. When installing, consider angle.
Classification

Angle (left and right)

Upper

Lower

XP30-BTE

45 deg.

40 deg.

20 deg.

XP30-BTA

45 deg.

40 deg.

20 deg.

XP30-TTA

70 deg.

50 deg.

70 deg.

XP50-TTA

65 deg.

50 deg.

60 deg.

XP70-TTA

65 deg.

45 deg.

65 deg.

XP80-TTA

65 deg.

45 deg.

75 deg.

XP90-TTA

75 deg.

50 deg.

60 deg.

Remark
1) Because XP30-BTA (BTE) uses STN Mono LCD, it has poorer clearness and expression angle.
2) XP30-BTA (BTE) can adjust Contrast. Adjust Contrast according to environment.

(4) Fixation
Fix the XGT by using the bracket as follows. (The bracket is included in the product.)
Fix through
Panel

bracket

Fix through
bracket

Fix through
bracket
Fix through
bracket

10-4

Chapter 10. Installation and Wiring

10.2 Wiring
It describes the wiring that you should know when installing the XGT Panel.

10.2.1 Power wiring


XGT Panel is divided into the DC product and the AC product.
Power

Name
XP30-BTE/DC
XP30-BTA/DC
XP30-TTA/DC
XP50-TTA/DC
XP70-TTA/DC
XP80-TTA/DC
XP30-BTA/D1
XP50-TTA/D1
XP70-TTA/AC
XP80-TTA/AC
XP90-TTA/AC

DC 24V

DC 12~24V
AC 100~240V

Remark
(1) If AC power is applied into the product for DC power, It may cause damage or fire. Be careful of connection.
(2) /DC is the product which use DC 24V, /D1 is the product which use DC 12~24V, and
/AC is the product which use AC 100~240V. When using the product, check the label in the back of the product.
The power terminal should have the following specification.
3.2

3.2

Less than

Less than

6.00mm

6.00mm

The power cable should have the following specification.


Type

Cable specification (Unit: )

Power and protection ground

1.5 (AWG16) ~ 2.5 (AWG12)

Remark
(1) Because of voltage down, we recommend the thick stranded cable (more than 2 ).
(2) If possible, use the stranded cable and connect with minimum length.
(3) To easily classify the cable, use the different colors cable respectively.
10-5

Chapter 10. Installation and Wiring

Wiring of power is as follows.

Ground

DC Power connection

AC Power
100~220 V

Ground
AC 100~240V
AC power connection

Remark
(1) When the regulation of power is bigger than provision, use the constant voltage transformer.
(2) In case power has much noise, use the insulation transformer.

10-6

Chapter 10. Installation and Wiring


Separate the XGT Panel power from the I/O device and main circuit device.
Main Power

XGT Panel power

Constant
Voltage
Transformer

I/O power
I/O device

Main circuit power


Main circuit device
Remark
Separate the XGT Panels power from the main circuit (high voltage, large current) cable, I/O signal cable.
If possible, install with a interval of more than 100mm.
Against the surge and lighting, use the surge absorber as follows.

XGT Panel

E1

E2

Surge absorber to prevent the lighting

Remark
(1) Separate the surge absorbers ground (E1) from XGT Panels ground (E2).
(2) Select a surge absorber so as not to exceed the maximum permissible voltage of a surge absorber even if power
voltage rises to maximum

When noise invades, use the insulation shield trans or noise filter.
Strand input power cable with minimum length and make sure the shield trans or noise filter is not crossed above the duct.

10-7

Chapter 10. Installation and Wiring


10.2.2 Ground wiring
(1) Our XGT Panel has enough anti-noise measure, so except that there are many noises specially, the ground is not
needed. When doing ground, please refer to the followings.
(2) The ground should be the exclusive ground.
The ground should be type 3 ground (ground resistor is less than 100).
(3) When not doing the exclusive ground, do common ground like figure B).
XGT
Panel

The other
devices

Type 3 ground

A) Exclusive ground: Best

XGT
Panel

The other
devices

XGT
Panel

The other
devices

Type 3 ground

B) Common ground: Good

C) Common ground: Poor

(4) Use the cable more than 2 mm2. Put the point of the ground near the XGT Panel and shorten the ground line.
Remark
If the ground status is poor or connected like C), it may cause malfunction or fault of communication.
Make sure that the ground status is good.

10-8

Chapter 11. Maintenance

Chapter 11. Maintenance


To keep the XGT Panel best, examine the XGT Panel.

11.1 Maintenance
Because an error may be developed by environment, the periodic maintenance is needed. You should check the following categories once
or twice every 6 months.
Maintenance category

Within the power change range


(Within 15% / +10%)

Power
Operating
temperature
Environment

Judgment standard

Operating
humidity
Vibration

Getting loose of power terminal


Getting loose of communication
connector

Measure
Modify the source of electric power in order to be in the
fluctuation range of a permissible voltage.

0 ~ + 50
Modify the operating temperature and humidity to be proper.
10 ~ 85%RH
No vibration

Use the anti-vibration rubber and make a count measure.

There is no unwinding

Screw the unwound terminal.

There is no unwinding

Screw the unwound terminal.

Amount of reserved part and


Reserved part

reservation

Refill the insufficiency and improve the reservation.

Check the status

11.2 Daily Maintenance


Check the followings daily.
Maintenance category
Status of panel adhesion

Getting loose of power terminal

Maintenance contents

connector
Indication LED

Measure

Check the unwound screw of the bracket

Fixed firmly

Wind the screw

Getting loose of power terminal screw

There is no unwinding

Wind the screw

Keep the proper distance.

Correction

Unwinding of fixed screw

There is no unwinding

Wind the screw

Check the lighting

Green LED should be turned on

Reduce the distance between


compressed terminals.

Status of communication

Judgment standard

Refer to the
appendix 1.

11-1

Chapter 11. Maintenance

11.3 Periodical Maintenance


Check the followings once or twice every six months and take measure.
Maintenance category

Maintenance method

Surrounding
temperature

0 ~ 50 C
Measure through

Environment Surrounding humidity

temperature/Hygrometer

Surrounding pollution

Measure of corrosive gas

10 ~ 85%RH
There is no corrosive gas.

degree

Measure
Modify it to meet the general
standard.
(environment standard in the
panel)

Shake the XGT Panel

Fixed firmly

Check by eye

There is no adhesion

Wind the screw by driver

There is no unwinding.

Wind the screw

Check by eye

Keep the proper distance.

Correction

Check by eye

There is no unwinding.

Power voltage maintenance

Check the power voltage of


input terminal of power by
test

AC100~240V: AC85~ 264V


DC24V: DC19.2 ~ 28.8V

Battery

Check when battery is


exchanged and voltage drop
is indicated (It is expressed
by system alarm)

Check the total of power


stoppage time and
guarantee duration
There is no battery voltage
drop indication

Checking by eye

Check the guarantee duration

XGT Panel
Status

Unwinding, swing

Judgment standard

Dust, foreign matter


adhesion
Unwinding of screw

Wind the screw


-

Reduce the distance


Connection
status

between compressed
terminals.
Unwinding of connector

LCD Backlight maintenance

Touch
status

11-2

Touch location error


Touch pad malfunction

Check at the Diagnostics of


XGT Panel
Checking by eye

Appropriate touch location

Wind the fixed screw of


connector
Supply power modification
If guarantee duration is
exceeded even tough there is
no battery voltage drop
indication, change the battery.
When error occurs, change
the backlight.
Reset at the setting of XGT
Panel.

There is no damage or

When error occurs, change

scratch/pollution

touch pad.

Chapter 11. Maintenance

Remark
(1) Battery exchange time is expressed by alarm. System alarm is expressed when system alarm category is set at the XP-Builder
as follows.

(2) LCD backlights exchange is available for only XP50-TTA, XP70-TTA, XP80-TTA, XP90-TTA. In case of XP30-BTE, XP30BTA, XP30-TTA, you have to exchange the LCD when error occurs or product life is finished because LCD and backlight is one
product.

11-3

Chapter 12. EMC Standard Certification

Chapter 12. EMC Standard Certification


12.1 Requirement for EMC Standard Certification
EMC command is regulated on It doesnt produce the Strong electromagnetic waves: Emission and It is not affected by electromagnetic
wave from external: Immunity. The following is describing the contents to meet the EMC command when configuring the system by using
the XGT Panel. This is a summary document for the request and standard which our company has obtained from EMC but we don't assure
that all devices manufactured according to these contents are not suitable for the below standards. The final manufacturer needs to finally
judge about the fitness method or fitness judgment of EMC command.

12.1.1 CE standard certification


The XGT Panel applies EN61000-6-4, EN61000-6-2, EN61000-3-2 and EN61000-3-3 among the CE standard.
Standard

Result

1. Emission
Conducted emission

EN61000-6-4:2001

Radiated emission

EN61000-6-4:2001

Harmonic current emission

EN61000-3-2:2000

Voltage fluctuations and flicker

EN61000-3-3:1995+A1:2001

NARE2)
NT RE3)
RE2)
NA
RE3)
NT

2. Immunity
Electrostatic discharge

Fast transient
Radio-frequency amplitude modulated electromagnetic field
(80-1000MHz)
Radio-frequency common mode
Surges
Voltage dips and interruptions

EN61000-6-2:2001
(EN61000-42:1995+A1:1998+A2:2001)
EN61000-6-2:2001
(EN61000-4-4:2004)
EN61000-6-2:2001
(EN61000-4-3:2002)
EN61000-6-2:2001
(EN61000-4-6:1996+A1:2001)
EN61000-6-2:2001
(EN61000-4-5:1995+A1:2001)
EN61000-6-2:2001
(EN61000-4-11:1994+A1:2001)

C
C
C
C
RE2)

NA
C RE3)

RE1) C=Conform
NC=Not Conform NT=Not Tested
NA=Not Applicable
RE2) Applicable to the only XP30-BTE/DC, XP30-BTA/DC, XP30-TTA/DC, XP50-TTA/DC, XP70-TTA/DC, XP80-TTA/DC
RE3) Applicable to the only XP70-TTA/AC, XP80-TTA/AC, XP90-TTA/AC

Directive:
Electromagnetic Compatibility Directive 89/336/EEC amended by the Directive 93/68/EEC

12-1

Chapter 12. EMC Standard Certification


12.1.2 KCC standard certification
The XGT Panel acquire the electromagnetic fitness registration (KCC specification) certified by wave laboratory under informationcommunication part.

A grade device
This device acquires KCC for business. Be careful that.
If device is not purchased properly, exchange it to device for home.

12.2 Requirement for Low Voltage Command Suitability


It is required to get the needed Stability for the device operated at AC50~1000V, DC75~1500Vs power. The following describes attention
about installation and wiring for the suitability when using the XGT Panel. Though the following data is made by requirement of regulation and
standard, we dont guarantee that all devices are suitable for the above command. The method to be suitable for the EMC command and
judgment of suitability should be finally made by device manufacturer himself.

12.2.1 Standard certification for XGT Panel


XGT Panel is according to the EN6100-1 (stability of device used in the measure, control laboratory).
XP70-TTA/AC among the XGT Panel is made to meet the above standard.

12.2.2 Selection of XGT Panel


(1) XP70-TTA/AC, XP80-TTA/AC, XP90-TTA/AC
Because the Power module whose rated input voltage is AC110/220V has danger voltage (voltage of more than 42.4V), the
product which is suitable for CE mark is having the improved insulation between internal 1 and 2.

(2) XP30-BTE/DC, XP30-BTA/DC, XP30-TTA/DC, XP50-TTA/DC, XP70-TTA/DC, XP80-TTA/DC


The I/O module under DC24V exceeds the range of low voltage command target.

12-2

Appendix 1. Troubleshooting

Appendix 1. Troubleshooting
1. Type of Problem
It classifies problems from XGT Panel including an indicated figure, indication of the object, and problems appeared when
downloading. Refer to the following chart.
Classification of problem

Description

Problem when starting

Malfunction when starting.


Please refer to the 2. problem when starting.

Problem when touching

In case that there is no reaction when touching.


Please refer to the 3. reaction problem when touching.

Display problem of figure and


object.

In case that the figure or object is different from when editing.


Please refer to the 4. Indication problem of figure and object.

Communication problem

In case that communication is not executed properly.


Please refer to the 5. Communication problem.

Error message when


executing program

In case that an error message occurs when operating the XGT Panel.
Please refer to the 6. Error message when executing program.

2. Problem when Starting


Why does black screen shows up when turning on the device?
Phenomenon. When turning on the device, black screen shows up and the booting is impossible.
<Reason>
1) Because the device is not set as a booting mode.
2) Black screen may appear because of malfunction of backlight.
<Solution>
1) Because the device is not set as a booting mode, the above problem can occur. Check whether the number 2 switch at
DIP switch in the back of the device is in A direction or not.
When is LED color changed?
Check the followings.
Display color
RED
GREEN

Contents
Communication time-out or system alarm which is registered as a system alarm at
the builder occurs in the HMI. (It is not recovered)
OS booting status, HMIs monitoring status, HMIs not monitoring status.
(including image data, diagnosis, setting , and engine update)

App.1-1

Appendix 1. Troubleshooting

3. Reaction Problem when Touching


When touching the screen it reacts in a different area or it may not react at all?

Phenomenon. When touching the screen it reacts in a different area or it may not react at all.
<Reason>
1) Touchs Calibration setting is not proper.
2) Touch panel may be a break down.
<Solution>
1) Redo Calibration setting about touch. Refer to the [Device manual Ch.4.1 Touch Calibration].
2) It you cant go to setting menu, connect mouse to USB port and use mouse.
Buzzer does not sound.

Phenomenon. When pressing buzzer, buzzer does not sound.


<Reason>
1) When that the switch operates but the buzzer doesnt sound, the buzzer is set as no sound.
2) If the switch doesnt work too, it seems that some error occurs in the touch function.
<Solution>
1) Redo environment setting for buzzer to sound. Refer to the [device manual Ch.4.7 Environment Setting].
2) After setting to use buzzer, check whether the buzzer sounds or not in the 1)s setting windows.

4. Display problem of Figure and Object


The shape of object is not shown or the number or character value which has to be shown is not shown.
Phenomenon. The shape of object is not shown or the number or character value which has to be shown is not shown.
<Reason>
The connection with PLC connected with each project is disconnected or NAK occurs.
<Solution>
1) When the communication is executed at first, Check the cable connected with PLC is OK or not.
2) If object where the offset is set is not shown, check whether address range is exceeded or not.
3) In case that communication is not OK, when communication is abnormal, the following message shows up in the XGT
Panel.
Object type
Bit Switch
Word Switch
Change Screen Switch
Special Switch
Multi Switch
Bit Lamp
Word Lamp
App.1-2

Phenomenon
The switch is expressed but it doesnt work.
The switch is expressed but it doesnt work.
The switch is expressed but it doesnt work.
The switch is expressed but it doesnt work.
The switch is expressed but it doesnt work.
Image is not shown.
Image is not shown.

Appendix 1. Troubleshooting
Object type
N-State Lamp
Clock
Bit Message
Word Message
Numeric Display
Numeric input
Text Display
Text Input
Bit Window
Word Window
Bit Part
Word Part

Animation
Bar Graph
Pie Graph
Meter Graph
Closed Graph
Trend Graph
History Alarm Viewer
Datalist
Logging Viewer
Navigator

Phenomenon
Image is not shown.
Present time is shown.
Message is not shown. When designating the background image, image is shown as it is.
Message is not shown. When designating the background image, image is shown as it is.
The value is not shown. When designating the background image, image is shown as it is.
The value is not shown. When designating the background image, image is shown as it is.
Character string is not shown. When designating the background image, image is shown as it is.
Character string is not shown. When designating the background image, image is shown as it is.
The window screen set in the object is not shown. But if communication is set with other object in
the same window screen, it can be shown by that object.
The window screen set in the object is not shown. But if communication is set with other object in
the same window screen, it can be shown by that object.
The part screen set in the object is not shown. But if communication is set with other object in the
same part screen, it can be shown by that object.
The part screen set in the object is not shown. But if communication is set with other object in the
same part screen, it can be shown by that object.
Animation is not shown.
Graph is not shown. When designating the background image, image is shown as it is.
Graph is not shown. When designating the background image, image is shown as it is..
Graph is not shown. When designating the background image, image is shown as it is.
Graph is not shown. When designating the background image, image is shown as it is.
X, Y axis is shown normally but trend axis is not normally shown. When designating the
background image, image is shown as it is.
Change doesnt occur. When communication is abnormal, alarm occurs because it cant know
the status of alarm target device. But previous alarm data shows up as it is.
Value is not shown. Lattice of viewing data list of object is shown as it is.
Change doesnt occur. When communication is normal, the recorded log data is shown normally.
But, log data is shown as # when communication is abnormal.
Change doesnt occur. Because it shows the group of alarm already developed, though
communication is abnormal, if it has alarm data already developed, it shows the name of group
where each alarm is included.

The number indication object value is shown as # or ~.


Phenomenon. The number indication object value is shown as # or ~.
(Same phenomenon occurs at the number input device, viewing data list, and viewing logging)
<Reason>
1) This happens when digit is not correct or type is not BCD.
<Solution>
1) When the number to be expressed exceeds the number set in the object, # is expressed. In case of this, set the digit
largely and after download again, execute program again.
2) When the numeric display object is expressed as BCD type, the data whose type is not BCD is expressed as ~. In case
of this, adjust device value as BCD type.
3) This phenomenon occurs at the data list object, numeric input, numeric display device, and logging viewer.

App.1-3

Appendix 1. Troubleshooting

After switching the screen, the previous screen remains for a few minute.
Phenomenon. After switching the screen, when there is no background or image in the part or number indication device, the
previous screen remains for a few minute because of change of part.
<Reason>
After switching the screen, when connection is set up multiply or communication time-out occurs, the screen of previous part
remains in some object.
<Solution>
1) Its normal status. In case that multiple connection or communication is not good, when switching the screen, the remains
of previous screen can occur during the time-out hour.
The folded object doesnt sequentially show up.
Phenomenon. The number under the data list shows up above data list.
<Reason>
1) The device value is expressed at the top of object screen.
<Solution>
1) Its normal status. The folded window or part object is not included in screen, regardless of sequence of drawing, the
object changed recently is expressed at top of screen. So if possible, do not fold the object in screen.

The object always shows up above the figure.


Phenomenon. I downloaded the figure above the object in XP-Builder, but the object always shows up above the figure.
<Reason>
1) In XGT Panel, The object always shows up above the figure.
<Solution>
1) Its normal status. The object always shows up above figure in the XGT Panel.

App.1-4

Appendix 1. Troubleshooting

5. Communication Problem
It seems that communication does not work.
Phenomenon. On the screen where the object is not many, communication works but when you move the screen where the
object is many, timeout occurs.
<Reason>
1) In the device setting, the communication time-out is set to be too short.
<Solution>
1) It occurs because timeout is set much smaller than sum of request time of communication data and response time from
PLC. In the device setting at the XP-Builder, after setting communication time out to be big, download program and
execute again.
It seems that communication doesnt work.
Phenomenon. Communication doesnt work.
<Reason>
1) Communication setting or cable may be not normal.
<Solution>
1) In case of RS-232C, check whether connection setting is normal or not in XP-Builder.
2) In case of RS-422/485, check whether station and communication connection setting is normal or not.
3) If 1), 2) is normal, do diagnosis about PLC-RS232C, PLC-RS485/422 at the Serial diagnosis screen of device menu.
Refer to the [Device manual ch.5.6 Serial Communication Diagnosis]
4) If 3) is normal, check whether connection cable has error or not.
5) In case of Ethernet, check the port and IP setting about relative PLC.

App.1-5

Appendix 1. Troubleshooting

6. CF/USB Removal of Memory Card


When removing the CF/USB memory card, device is stopped for some times.
Phenomenon. This happens when doing data backup including logging, recipe.
<Reason>
1) This happens because memory card is removed when doing data backup.
<Solution>
1) If possible, when monitoring XGT Panel, do not remove the memory card and after going out to the waiting screen,
execute the removing.
2) Inescapably you have to remove it during the operation, remove when backup does not occur. If the above phenomenon
occurs, it works normally after about 10 seconds.

App.1-6

Appendix 1. Troubleshooting

7. Error Message during Execution of Program


In case that problems occur during execution of XGT Panel including the start of device, diagnosis of device and environment setting,
project download, monitoring of control device, and error messages occur as type of box. At this time the message indicates the code
made by 4 digit number. The front 2 number indicate code of object and work, the rear 2 number is message number. In case that
the present error message is indicated as [0101], an error message occurs when doing diagnosis about the status of NVRAM. When
an error message occurs, refer to the rows number and sequence and find the category of reason and measure.
Error code
Object
Type

Address

Device
setting

0x01

0x02

Error message

0x01

XGT
Panel

NVRAM Data Access ...


FAILED!

0x02

XGT
Panel

BATTERY STATUS ... NOT


GOOD!

0x03
Device
diagnosis

Occurrence
location

0x04

XGT
Panel
XGT
Panel

Write Operation FAILURE!


Read Disk Information Error!

0x05

XGT
Panel

Write Operation FAILURE!

0x06

XGT
Panel

Read Disk Information Error!

0x01

XGT
Panel

Invalid timeout value.

0x02

XGT
Panel

Not found XGT Panel


configuration file.

0x03

XGT
Panel

Please enter an integer


between 0 and 255.

Viewing
device
information

0x03

0x01

XGT
Panel

No project in XGT Panel.

XGT Panel
Update

0x04

0x01

XGT
Panel

Failed to Start engine.


Please update engine again.

Switch

h05

h01

XGT
Panel

Invalid password.

Reason and measure


Failed to check whether backup memory is normal
or not. If this symptom is repeated, contact the near
Customer Service Center.
Backup data is not valid. If this symptom is repeated
when turning power off and on, remove XGT
Panels power and exchange the battery.
The built-in Flash disk has an error. Contact the
near Customer Service Center.
The built-in Flash disk has an error. Contact the
near Customer Service Center.
Check that CF card is empty, and equip CF card
and test again. If same symptom is repeated, CF
card or CF card slot of XGT Panel may have a
problem.
Check that CF card is empty, and equip CF card
and test again. If same symptom is repeated, CF
card or CF card slot of XGT Panel may have a
problem.
You inputted the wrong time which is not within
backlight setting time range. Input the effective time.
There is no setting information data of XGT Panel. If
this symptom is repeated when turning power off
and on, contact the near Customer Service Center.
When setting IP, the values within 0~255 are
effective. Input the value within the above range.
Now, there is no downloaded project so you cant
see connection information. Download the project
from XP-Builder.
Because of update error or Flash disk error,
program cant be executed. If you can update, redo
the above procedure. If you cant, contact the near
Customer Service Center.
There is password in the each object. When editing
the project downloaded in the present device, input
the designated password at the project property
information.

App.1-7

Appendix 1. Troubleshooting
Error code
Object
Type

Number
indication
device/
Number
input device

Address

Occurrence
location

Error message

Reason and measure

h01

XGT
Panel

Can't write Data.

Because of communication error, the value cant be


inputted. Check the communication status and input
again.

h02

XGT
Panel

No input Data.

You tried to input with no value. Input the value

Exceeded the max length.

You exceed the maximum length to input.

0x03
0x06
0x04
0x05

0x06

XGT
Panel
XGT
Panel
XGT
Panel
XGT
Panel

Exceeded the minimum


Value.
Exceeded the maximum
Value.
Invalid at Input Case.

You exceed the maximum value to input.


You exceed the minimum value to input.
When you input the value, input cant be done
because of wrong input. Check the input condition
of each object in the Builder and input again.

Lamp

0x07

None

Character
indication
device/
Character
input device

0x08

None

Message

0x09

None

Clock

0x0A

None

Animation

0x0B

None

Graph

0x0C

None

Window

0x0D

None

Part

0x0E

None

History alarm

0x0F

None

Flow alarm

0x20

None

0x21

None

0x22

None

0x23

None

0x24

None

0x25

None

System
alarm
Scheduler
related
Recipe
related
Logging
related
Data list

App.1-8

Appendix 1. Troubleshooting
Error code
Object
Type

Address

0x00

0x01

0x02

0x03

0x04
Project
download

Occurrence
location

Error message

Reason and measure

Abnormal send-payload.
Please download project
again.

Communication status is abnormal. Check the


connection of communication cable.

There's not Password File.

This message shows up when making it newly


because there is no password setting file in the
device. When making it newly, it is initialized with no
password.

Failed to Create Password


File.

It make new password setting file when there is no


password setting file. But downloading is stopped
when it fails to make this file because of device
error. If this problem is repeated, Contact the near
Customer Service Center.

Invalid Backup Media.

Communication status is abnormal. Route


information is not correct to save project data. If this
problem is repeated, Contact the near Customer
Service Center.

Failed to Create Inited


Version File.

In case that the version information file doesnt exist


in the device, that file is made newly. In case that
the device has error and fails to make that file,
download is stopped. If this problem is repeated,
Contact the near Customer Service Center.

File Size Error.

There is version information file. In case that


because of error of device, it fails to read version
information, because the device doesnt know
version, download is stopped. If this problem is
repeated, Contact the near Customer Service
Center.

XP Builder

Failed to get Project ID.

In case of not reading file where project property is


included, download is stopped. If this problem is
repeated, Contact the near Customer Service
Center.

XP Builder

Failed to read history alarm


data.

In case of not reading information about alarm


history because of error of NVRAM, download is
stopped. If this problem is repeated, Contact the
near Customer Service Center.

Failed to read CF Card


information.

Project is set to store data at CF card equipped at


device. By the way, now it cant read information
about CF card. Check the installation status of CF
card and if it is normal, check the CF card. If this
problem is repeated, contact Customer Service
Center.

XGT
Panel

XP Builder

XP Builder

XP Builder

XP Builder

0x26

0x05

0x06

0x07

0x08

XP Builder

XP Builder

App.1-9

Appendix 1. Troubleshooting
Error code
Object
Type

Project
download

0x26

Address

Error message

Reason and measure

0x09

XP Builder

Failed to read USB


information.

Project is set to store data at USB storage device


equipped at device. By the way, now it cant read
information about USB storage device. Check the
installation status of USB storage device and if it is
normal, check USB storage device. If this problem
is repeated, contact Customer Service Center.

0x0A

XP Builder

Failed to read Flash memory


information.

In case that it cant know information about memory


status, download is stopped. If this problem is
repeated, contact Customer Service Center.

Failed to clear Temp


Directory.

In case that because of error of Flash Disk, it cant


delete the directory made temporally for download
because of error of Flash Disk, download is
stopped. If this problem is repeated, contact
Customer Service Center.

Failed to delete Font File.


Please reboot XGT Panel.

In case that it fail to delete the font file of previous


project because of error of XGT Panel, download is
stopped. If this problem is repeated, contact
Customer Service Center.

Failed to delete Image File.


Please reboot XGT Panel.

In case that it fail to delete the image file of previous


project because of error of XGT Panel, download is
stopped. If this problem is repeated, contact
Customer Service Center.

0x0B

XP Builder

0x0C

XGT
Panel

0x0D

XGT
Panel

0x0E

XGT
Panel

Failed to delete Sound File.


Please reboot XGT Panel.

In case that it fail to delete the sound file of


previous project because of error of XGT Panel,
download is stopped. If this problem is repeated,
contact Customer Service Center.

0x0F

XGT
Panel

There's no downloaded
project. It needs to download
whole project

It cant download part or fixed part in case there is


no downloaded project. In case of this, download
again. If this problem is repeated, contact Customer
Service Center.

Backup path is invalid.


Please check the path that
project is downloaded.

When user change the storage location of project


data including image and font, if there is not
respective routine, it make newly. By the way,
download is stopped in case it fails to make newly.
When it is designated as CF card, it can occur in
case CF card is not installed. If this problem is
repeated and not referred in the above, contact
Customer Service Center.

0x10

App.1-10

Occurrence
location

XP Builder

Appendix 1. Troubleshooting
Error code
Object
Type

Address

0x11

Project
download

0x26

Occurrence
location

XGT
Panel

Error message

Failed to delete previous


project archive. Please
reboot XGT Panel.

0x12

XGT
Panel

Failed to delete past project


data files. Please download
project again.

0x15

XGT
Panel

Failed to initialize LOGGING


area in NV RAM. Please
download project again.

0x16

XGT
Panel

Failed to initialize RECIPE


area in NV RAM. Please
download project again.

0x17

XGT
Panel

Failed to initialize ALARM


area in NV RAM. Please
download project again.

0x18

XGT
Panel

Failed to install font files.


Please download project
again.

0x19

XGT
Panel

Failed to unmarshall
download file. Please
download project again.

0x1A

XGT
Panel

Failed to install new project


data files. Please download
project again.

0x1B

XGT
Panel

Failed to merge data files.


Please download project
again.

Reason and measure

The project backup file downloaded already can be


deleted because of error of XGT Panel. Reboot
XGT Panel. If this problem is repeated, contact
Customer Service Center.
When downloading, the log data area in the NVRAM is initialized in case of selecting previous
projects the monitor data deletion option. By the
way, in case of failing this, downloading is stopped.
If this problem is repeated, contact Customer
Service Center.
When downloading, the log data area in the NVRAM is initialized in case of selecting previous
projects the monitor data deletion option. By the
way, in case of failing this, downloading is stopped.
If this problem is repeated, contact Customer
Service Center.
When downloading, the alarm history in the NVRAM is initialized in case of selecting the previous
projects monitor data deletion option. By the way, in
case of failing this, downloading is stopped. If this
problem is repeated, contact Customer Service
Center.
The downloaded font file is moved into original
storage location but when this fails, downloading is
stopped. If this symptom is repeated, contact
Customer Service Center.
The project data is divided into several files
according to the contents but when this fails,
downloading is stopped. If this symptom is
repeated, contact Customer Service Center.
The data divided according to the contents is
moved to the original storage location but when this
fails, downloading is stopped. If this symptom is
repeated, contact Customer Service Center.
The downloaded project is not installed normally
because of error of the Flash Disk. Download the
project again. If this symptom is repeated, contact
Customer Service Center.
The downloaded project zip file is moved to the
original storage location but when it fails,
downloading is stopped. If this symptom is
repeated, contact Customer Service Center.

App.1-11

Appendix 1. Troubleshooting
Error code
Object
Type

Project
download

Project
download
from USB
storage
device

App.1-12

Address

Error message

Reason and measure

0x1C

XGT
Panel

Failed to save new project


archive. Please download
project again.

There is a program to reboot engine program after


downloading in the device but when it fails, this
message shows up. But because the downloading
is completed if you reboot engine directly, it works
normally. The program name to reboot is
startup.exe and it can be installed by engine
upgrade function.

0x1D

XGT
Panel

Failed to XGP Panel startup


program. Please update
XGT Panel Software.

It cant find software to reboot XGT Panel.


Update the XGT Panel.

0x1E

XGT
Panel

Project data is not


downloaded. Please
download project again.

The project data was not downloaded normally


because of communication error. Check the
connection status of communication cable and If
this symptom is repeated, contact Customer
Service Center.

0x1F

XGT
Panel/
XP-Builder

Failed to read Version


information file. Please
download project again.

There is version information file but when it cant


read file normally because of the device error,
downloading is stopped because it doesnt know
version. If this symptom is repeated, contact
Custom Service Center

0x51

XGT
Panel

Cannot find project data in


USB Storage

There is no USB or device status of USB is not


good or project is not saved properly.

0x52

XGT
Panel

Project information file is not


in USB Storage.

The project is not saved normally in the USB.


Check whether there is XP_Project folder and
[project name].inf in the USB or not.

0x53

XGT
Panel

Failed to read project


information file.

It cant read project information file because the


project is not saved in the USB normally. Save the
project again from XP-Builder to the USB.

0x26

0x27

Occurrence
location

0x54

XGT
Panel

Device type is not matched.

The connected device type is not same as the


device type set in the project in the USB. In case of
this, project cant be downloaded into the device.
Edit the project again or download according to the
connected device.

0x55

XGT
Panel

Cannot read user password.

Information about the password cant be red


because of the device error. If this symptom is
repeated, contact Customer Service Center.

Appendix 1. Troubleshooting
Error code
Object
Type

Address

0x56

Project
download
from USB
storage
device

0x27

Occurrence
location
XGT
Panel

Error message

Reason and measure

Password is not matched.

When saving the project, the password inputted by


user is not same as present connection password.
Input correct password and save the project.

0x57

XGT
Panel

Cannot read XGT Panel


software version.

There is version information file but when it cant


read file normally because of the device error,
downloading is stopped because it doesnt know
version. If this symptom is repeated, contact
Customer Service Center.

0x58

XGT
Panel

XGT Panel software is old


version. Please update XGT
Panel.

The version of XP-Builder where project is saved is


not compatible with present XGT Panel. Update the
XGT Panel.

0x58

XGT
Panel

XP-Builder is old version.


Please update XP-Builder.

The version of XP-Builder where project is saved is


not compatible with present XGT Panel. Update the
XGT Panel.

0x59

XGT
Panel

Cannot read download data


format version.

There is storage structure version information file.


But when it cant read this file because of the device
error, downloading is stopped because it doesnt
know the version. If this symptom is repeated,
contact Customer Service Center.

0x5A

XGT
Panel

Download data format


version is not matched.
Please update XGT Panel.

Data storage type is not correct. Update XGT


Panel.

0x5A

XGT
Panel

Download data format


version is not matched.
Please update XP-Builder.

Data storage type is not correct. Update the XPBuilder.

0x5B

XGT
Panel

Data file path is invalid.

There is no project data file at designated location.


Check the connection status of USB and if there is
no error, save the project to USB again.

0x5C

XGT
Panel

Download file name length is


invalid.

The name of project data file is not saved correctly.


Save the project at the USB again. If this symptom
is repeated, contact Customer Service Center.

Cannot find download file.

The project data file cant be found. Save the project


data file at the USB again. When this symptom is
repeated, check the USB. If there is no error,
contact Customer Service Center.

0x5D

XGT
Panel

App.1-13

Appendix 1. Troubleshooting
Error code
Object
Type

Project
download
from USB
storage
device

App.1-14

Address

Occurrence
location

Error message

0x5E

XGT
Panel

Download file size is invalid.

0x5F

XGT
Panel

Cannot find project backup


file.

0x60

XGT
Panel

Project backup file size is


invalid.

0x61

XGT
Panel

Font file name length is


invalid.

0x62

XGT
Panel

Font file is not downloaded.

0x63

XGT
Panel

Font file size is invalid.

0x64

XGT
Panel

Cannot unmarshall
download file.

0x65

XGT
Panel

Cannot delete previous


project data.

0x66

XGT
Panel

Cannot move new font files.

0x67

XGT
Panel

Cannot move new project


data files.

0x68

XGT
Panel

Cannot move project backup


file.

0x27

Reason and measure


The project data file is not saved correctly. Save the
project data file at the USB again. When this
symptom is repeated, check the USB. If there is no
error, contact Customer Service Center.
The project backup file which should be
downloaded is not downloaded because of
communication error. Download again.
The project backup file is saved incorrectly. Save
the project at the USB storage equipment again.
When this symptom is repeated, check the USB
storage equipment and if the USB is normal,
contact Customer Service Center.
The font files name is saved incorrectly. Save the
project in the USB again. If this symptom is
repeated, contact Customer Service Center.
The font file which is needed for project is not saved
in the USB storage equipment. Save the project in
the USB. If this symptom is repeated, contact
Customer Service Center.
The font file is not saved correctly. Save the project
at the USB. Save the project at the USB. If this
symptom is repeated, check the USB and if the
USB is normal, contact Customer Service Center.
The data cant be analyzed because the project
data file is not saved correctly. Save the project at
the USB again. If this symptom is repeated, check
the USB and if the USB is normal, contact
Customer Service Center.
The data of the project cant be deleted because of
device error. If this symptom is repeated, check the
USB and if the USB is normal, contact Customer
Service Center.
Downloaded font file is moved to the original
storage location. But when it fails, the downloading
is stopped. If this symptom is repeated, contact
Customer Service Center.
The project data classified according to the content
is moved to the original storage location. But when it
fails, the downloading is stopped. If this symptom is
repeated, contact Customer Service Center.
The downloaded project zip data is moved to the
original storage location. But when it fails, the
downloading is stopped. If this symptom is
repeated, contact Customer Service Center.

Appendix 1. Troubleshooting
Error code
Object
Type

Address

0x01

0x02

0x03

0x04
XGT Panel
booting

Occurrence
location

XGT
Panel

XGT
Panel

XGT
Panel

XGT
Panel

Error message

Previous instance is not


terminated.

XGT Panel software was already started. Reboot


the device. If this symptom is repeated, contact
Customer Service Center.

Start Server Fail. Restart


XGT Panel

The XGT Panel software cant initialize the


communication status normally. Check the
communication status again. If this symptom is
repeated when communication is normal, contact
Customer Service Center.

Failed to Start Echo Server.

The XGT Panel software cant initialize the


communication status normally. Check the
communication status again. If this symptom is
repeated when communication is normal, contact
Customer Service Center.

Failed to accept connection.

The XGT Panel software cant initialize the


communication with the XP-Builder normally. Check
the communication status again. If this symptom is
repeated when communication is normal, contact
Customer Service Center.

Failed to rename
UpdateNew.exe

In the present XGT Panel the new updated XGT


Panel softwares name can not be changed.
After rebooting the XGT Panel, update again. When
rebooting, if you cant start engine, delete
\\FlashDisk\LSISProduct\UpdateNew.exe in the
XGT Panel. Then if you touch Update.exe and
execute the XGT Panel, it can be update mode. Try
update again. If this symptom is repeated, contact
Customer Service Center

0x28

0x05

0x29

XGT
Panel

Reason and measure

0x06

XGT
Panel

Failed to Delete Update.exe.

The new module is downloaded by the XGT Panel


update but the previous module is not deleted.
Reboot the device. If the XGT Panel software is not
started normally, touch
\\FlashDisk\LSISProduct\Update.exe in the XGT
Panel. At this time, if XGT is set as update mode,
update again. If this symptom is repeated, contact
Customer Service Center.

0x30

XGT
Panel

Failed to modify password


file.

The device connection password cant be modified


because of error of Flash Disk of XGT Panel.
Reboot the device. If this symptom is repeated,
contact Customer Service Center.

App.1-15

Appendix 1. Troubleshooting
Error code

Occurrence
location

Error message

0x31

XGT
Panel

Password-related command
transmission payload error

It failed to set and modify password because of


communication status error. If this symptom is
repeated, contact Customer Service Center.

0x32

XGT
Panel

There is no XGT Panel


connection setting file.

The connection setting file of XGT Panel cant be


found.

0x33

XGT
Panel

Modified content cant be


saved in the XGT Panel
connection setting file.

The modified information cant be saved at the


connection setting file of XGT Panel. If this symptom
is repeated, contact Customer Service Center..

0x34

XGT
Panel

Failed to set the time

The XGT Panels time cant be set. If this symptom


is repeated, contact Customer Service Center.

0x21

XGT
Panel/
XP-Builder

Failed to Create Initialized


Module Version File.

Because the each module version information cant


be read because of XGT Panels error, it failed to
initialize. If this symptom is repeated, contact
Customer Service Center.

0x22

XGT
Panel/
XP-Builder

Module version file size is


invalid.

The each module version information cant be read


because of XGT Panels error. If this symptom is
repeated, contact Customer Service Center.

0x23

XGT
Panel/
XP-Builder

Can't Read module version


file.

The each module version information cant be read


because of XGT Panels error. If this symptom is
repeated, contact Customer Service Center.

There's no file to download.

The version information list to update is empty.


Check the module folder newly designated at XPBuilder and if there is no error, download XGT
Panel module and try update again. If this symptom
is repeated, contact Customer Service Center.

Downloaded file is not


Module to download.

The wrong file which is not in the new module list of


XGT Panel is downloaded. Try update of XGT
Panel again. If this symptom is repeated, contact
Customer Service Center.

Not enough space in flash


memory.

The space to copy new module in XGT Panel is not


enough. After deleting the unnecessary file or
backing up the previous file to the movable storage
equipment, try update again. If this symptom is
repeated after deleting, contact Customer Service
Center.

Object
Type

Communicati
on between
other XP
BuilderXGT Panel

XGT panel
S/W update

Address

0x30

0x24

0x25

0x30

App.1-16

Reason and measure

0x26

XP-Builder

XP-Builder

XGT
Panel

Appendix 1. Troubleshooting
Error code
Object
Type

Address

Occurrence
location

Error message

XGT panel
S/W update
0x27

0x28

XGT
Panel

Failed to Start Engine.


Please update engine again.

0x2A

XGT
Panel

Failed to write Write Data to


Module version File.

It is failed to record the version information during


update of XGT Panel. If this symptom is repeated,
contact Customer Service Center.

There's no downloaded file.

To reboot the engine is not available because of


wrong file which is developed by downloading
wrong module or communication error.
Touch \\FlashDisk\LSISProduct\Update.exe and set
the device as update mode. Then update again. If
this symptom is repeated, contact Customer
Service Center.

(improper communication
command)
Current state is not
authorized.

To reboot the engine is not available because of


wrong file which is developed by downloading
wrong module or communication error.
Touch \\FlashDisk\LSISProduct\Update.exe and set
the device as update mode. Then update again. If
this symptom is repeated, contact Customer
Service Center.

(improper communication
command)
Modules to download is not
listed up yet.

To reboot the engine is not available because of


wrong file which is developed by downloading
wrong module or communication error.
Touch \\FlashDisk\LSISProduct\Update.exe and set
the device as update mode. Then update again. If
this symptom is repeated, contact Customer
Service Center.

0x2C

0x30

Failed to Copy module .dll

The new module is not installed because of XGT


Panels error. After rebooting the device, touch
\\FlashDisk\LSISProduct\Update.exe and set the
device as update mode. Then update again. If this
symptom is repeated, contact Customer Service
Center.
To reboot the engine is not available because of
wrong file which is developed by downloading
wrong module or communication error.
Touch \\FlashDisk\LSISProduct\Update.exe and set
the device as update mode. Then update again. If
this symptom is repeated, contact Customer
Service Center.

0x2B

XGT panel
S/W update

XGT
Panel

Reason and measure

0x2D

XGT
Panel

XGT
Panel

XGT
Panel

App.1-17

Appendix 1. Troubleshooting
Error code
Object
Type

Address

0x2E

App.1-18

Occurrence
location

XGT
Panel

Error message

Failed to Initialize Update


program.

Reason and measure


XGT cant be set as update mode because of XGT
Panel error. After downloading new XGT Panel
module through homepage, etc., copy
UpdateNew.exe file among new module to the
\\FlashDisk\LSISProduct\ directory of XGT Panel
through the movable storage equipment. Then
reboot the XGT Panel and go update mode and
update again. If this symptom is repeated, contact
Customer Service Center.

Appendix 2. Dimension

Appendix 2. Dimension (Unit: mm)


(1) XP30-BTE/DC

(2) XP30-BTA/DC, XP30-TTA/DC

App.2-1

Appendix 2. Dimension

(3) XP50-TTA/DC

(4) XP70-TTA/AC, XP70-TTA/DC

App.2-2

Appendix 2. Dimension
(5) XP80-TTA/AC, XP80-TTA/DC

(6) XP90-TTA/AC

App.2-3

Warranty and Environmental Policy

Warranty

1. Warranty Period
The product you purchased will be guaranteed for 18 months from the date of manufacturing.
2. Scope of Warranty
Any trouble or defect occurring for the above-mentioned period will be partially replaced or repaired. However, please note the
following cases will be excluded from the scope of warranty.
Any trouble attributable to unreasonable condition, environment or handling otherwise specified in the manual,
Any trouble attributable to others products,
If the product is modified or repaired in any other place not designated by the company,
Due to unintended purposes
Owing to the reasons unexpected at the level of the contemporary science and technology when delivered.
Not attributable to the company; for instance, natural disasters or fire

3. Since the above warranty is limited to HMI unit only, make sure to use the product considering the safety for system
configuration or applications.

Environmental Policy

LS Industrial Systems Co.,Ltd supports and observes the environmental policy as below.

Environmental Management
LS Industrial Systems considers the
environmental preservation as the preferential
management subject and every staff of LS
Industrial Systems use the reasonable
endeavors for the pleasurably environmental
preservation of the earth.

About Disposal
LS Industrial Systems PLC unit is designed
to protect the environment. For the disposal,
separate aluminum, iron and synthetic resin
(cover) from the product as they are
reusable.

LS values every single customers.


Quality and service come first at LSIS.
Always at your service, standing for our customers.

http://eng.lsis.biz

10310000867

HEAD OFFICE
LS tower, Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do
1026-6, Korea http://eng.lsis.biz
e-mail: [email protected]
Tel. (82-2)2034-4689, 4888
Fax.(82-2)2034-4648
LS Industrial Systems Tokyo Office >> Japan
Address: 16F, Higashi-Kan, Akasaka Twin Towers 17- 22,
2-chome, Akasaka, Minato-ku, Tokyo 107-8470, Japan
Tel: 81-3-3582-9128
Fax: 81-3-3582-2667
e-mail: [email protected]
LS Industrial Systems Dubai Rep. Office >> UAE
Address: P.O.BOX-114216, API World Tower, 303B, Sheikh
Zayed road, Dubai, UAE.
e-mail: [email protected]
Tel: 971-4-3328289 Fax: 971-4-3329444
LS-VINA Industrial Systems Co., Ltd. >> Vietnam
Address: LSIS VINA Congty che tao may dien Viet-Hung
Dong Anh Hanoi, Vietnam
e-mail: [email protected]
Tel: 84-4-882-0222 Fax: 84-4-882-0220
LS Industrial Systems Hanoi Office >> Vietnam
Address: Room C21, 5th Floor, Horison Hotel, 40 Cat Linh,
Hanoi, Vietnam
Tel: 84-4-736-6270/1 Fax: 84-4-736-6269
Dalian LS Industrial Systems co., Ltd, >> China
Address: No. 15 Liaohexi 3 Road, economic and technical
development zone, Dalian, China
e-mail: [email protected]
Tel: 86-411-8273-7777
Fax: 86-411-8730-7560

LS Industrial Systems (Shanghai) Co., Ltd. >> China


Address: Room E-G, 12th Floor Huamin Empire Plaza,
No. 726, West Yanan Road, Shanghai, China
Tel: 86-21-5237-9977
LS Industrial Systems(Wuxi) Co., Ltd. >> China
Address: 102-A National High & New Tech Industrial
Development Area, Wuxi, Jiangsu, China e-mail: [email protected]
Tel: 86-510-534-6666
Fax: 86-510-522-4078
LS Industrial Systems Beijing Office >> China
Address: B-tower 17th Floor, Beijing Global Trade Center building,
No. 36, BeiSanHuanDong-Lu, DongCheng-District, Beijing, China
Tel: 86-10-5825-6025
LS Industrial Systems Guangzhou Office >> China
Address: Room 1403, 14F, New Poly Tower, 2 Zhongshan Liu
Rad, Guangzhou, China
e-mail: [email protected]
Tel: 86-20-8326-6754
Fax: 86-20-8326-6287
LS Industrial Systems Chengdu Office >> China
Address: Room 2907, Zhong Yin B/D, No. 35, Renminzhong(2)Road, Chengdu, China
e-mail: [email protected]
Tel: 86-28-8612-9151
Fax: 86-28-8612-9236
LS Industrial Systems Qingdao Office >> China
Address: 12th Floor, Guodong building, No52 Jindun Road,
Chengdu, China
e-mail: [email protected]
Tel: 86-532-580-2539

LS Industrial Systems constantly endeavors to improve its product so that


Information in this manual is subject to change without notice.
LS Industrial Systems Co., Ltd 2009 All Rights Reserved.

Fax: 86-532-583-3793

2009. 10

You might also like