Safety Precautions
Please keep to the safety precaution, for it is to prevent accidents and potential danger from occurring.
Safety precaution is classified into Warning and Caution and their meanings are as follows.
Warning
Caution
Violating the instruction may result in slight personal injury or product damage.
The indicated illustrations on the product and in the manual have the following meanings.
Be cautious, for danger may be present.
Be cautious, for there is a possibility of an electric shock.
After reading the instruction manual, keep it handy for quick reference.
Safety Precautions
Design Precautions
Warning
Install a safety circuit external to the HMI to protect the whole control system in case of
external power supply trouble.
Serious trouble may occur to the entire system due to erroneous output/operation of the HMI.
Design Precautions
Caution
In/output signal or communication cable should be at least 100mm apart from
High-voltage/power wires.
Otherwise, it may cause erroneous output/operation.
Installation Precautions
Caution
Use the HMI in an environment that meets the general specification contained in this
manual or datasheet.
Otherwise, it could result in electric shock, fire, erroneous operation or deterioration.
In case of much vibration in the installed environment, be sure to insulate the HMI from
direct vibration.
Otherwise, it could result in electric shock, fire or erroneous operation.
Be sure not to let foreign substances such as conductive debris inside the product.
Otherwise, it could result in electric shock, fire or erroneous operation.
Safety Precautions
Wiring Precautions
Warning
Be sure to turn off the HMI and external power before wiring.
Otherwise, it may result in an electric shock or damage to the product.
Caution
Wire correctly by checking each of the products rated voltage and terminal layout.
Otherwise, it may result in fire, electric shock or erroneous operation.
Be sure not to let any foreign substances such as wiring debris inside the module.
Such debris may cause fire, damage or erroneous operation.
Safety Precautions
Turn off the PLC and external power when cleaning or tightening the terminal.
Otherwise, it may cause electric shock or erroneous operation.
Do not charge, disassemble, heat, short circuit, solder, etc. the battery.
Mishandling the battery may cause overheating, crack, fire and may result in injury or fire.
Caution
Do not disassemble PCB from the product case or modify the product.
Otherwise, it may result in fire, electric shock or erroneous operation.
Use cellular phone or walky-talky at least 30cm away from the PLC.
Otherwise, it may result in erroneous operation.
Disposal Precaution
Caution
When disposing of this product or battery, treat it as industrial waste.
Otherwise, it may cause poisonous pollution or explosion.
Revision History
Revision History
Version
Date
Contents
V1.0
07.4
First Edition
V2.0
09.10
The number of Users manual is indicated the right side of the back cover.
LS Industrial Systems Co., Ltd 2006
All Rights Reserved.
Revised location
CH4, CH5, CH6, CH8
CH7.1
CH7
CH7
CH9
CH9
CH3, CH12, APP2
CH7
CH7
CH1
CH2
CH3
CH5
APP2
CH3, CH10
APP2
CH6.7
CH4.1
Chapter. 5 Diagnostics.......................................................................................................5-1~5-5
5.1 Screen Diagnosis..............................................................................................................................................................5-1
5.2 Touch Diagnosis................................................................................................................................................................5-2
5.3 Backup Memory Diagnosis..............................................................................................................................................5-2
5.4 Flash Memory Diagnosis Function..................................................................................................................................5-3
5.5 CF Card Diagnosis............................................................................................................................................................5-3
5.6 Serial Communication Diagnosis ....................................................................................................................................5-4
5.7 LED Diagnosis...................................................................................................................................................................5-5
5.8 Aux Diagnosis....................................................................................................................................................................5-5
10
Category
Contents
Chapter 1
General Introduction
Chapter 2
System Configuration
Chapter 3
Standard Specification
Chapter 4
System Configuration
Chapter 5
Diagnostics
Viewing information of
PLC Connection Status
Transmission of Project
from USB Storage Device
Chapter 8
Chapter 9
It describes the way to backup recipe, logging and etc. files by using
storage devices.
Chapter 10
Chapter 11
Maintenance
It describes inspection category and method for long normal operation of PLC
system.
Chapter 12
EMC Standard
Appendix 1
Troubleshooting
Appendix 2
Dimension
Appendix 3
Warranty and
Environment Policy
Chapter 6
Chapter 7
It describes the way to execute the project by using USB storage device.
Remark
This manual doesnt describe connection with XP-Builder and PLC. For their own function, Please refer to the related
manuals.
1-1
1.2 Feature
XGT Panel has the following features.
(1) Diverse external interface
(a) It maximizes customs use by providing diverse external interface including USB, CF card and Ethernet.
Expansion connector
CF card
Communication
Module
Memory Interface
Logging data
Image/font data
USB host
Printer
Etc.
Tool port (RS-232C): XP-Builder
USB Storage
Device
Keyboard,
Mouse
(b) It can be connected with control device such as PLC, INVERTER.
It can be connected by RS-232C, RS-422/485, Ethernet (10/100 BASE-T).
Ethernet
XP-Builder
Inverter
Open network
1-2
Inverter
Battery Cover
RS232C
RS422/RS485
Terminal Block Type
USB Port
Upload
(b) It provides the transmission function from USB storage device.
Data change
1-3
1-4
1-5
1.3 Terminology
It describes terms used in this manual.
Term
1-6
Definition
Example
Module
A standard element that has a specified function which configures the system.
Devices such as I/O board, which inserted onto the mother board or base unit.
Unit
PLC system
XP-Builder
Cnet module
Computer Link
FEnet module
RTC
Number
Name
Front view
Description
1) Analog touch panel: User touch input
2) LCD: screen indication
Indicates operation status of device
LED Status
Green
Red
2-1
Number
Name
Description
CF card interface
Power connection
terminal
USB interface
It consists of 2 ports.
1) USB memory connection: logging/recipe/screen data backup
2) USB memory connection: project data transmission/backup
3) User interface connection: use of mouse/keyboard
4) Printer connection: printing is available
Extension port
Reset switch
TOOL interface
RS-232C interface
1) project data transmission
2) logging/recipe/alarm/screen data backup
3) machine software upgrade
Setting switch
No use
A setting
B setting
A setting
B setting
No use of Watchdog
A setting
B setting
No.2
No.3
No.4
Extension module
fixation hall
RS-422/485 connector
RS-232C connector
Ethernet terminal
FG terminal
Remark
(1) For details about communication connection, please refer to the communication user manual.
(2) For details about installation, please refer to the Chapter 10
2-2
Prevention
tape
2. XP30-BTE
2-3
Number
Name
Front view
Description
1) Analog touch panel: User touch input
2) LCD: screen display
Indicates operation status of module.
LED Status
Green
Red
Power terminal
cover
USB interface
Communication
interface
Reset switch
Battery cover
Tool interface
RS-232C interface
1) Project data transmission
2) Logging/recipe/alarm/screen data backup
3) Machine software upgrade
Setting switch
Reserved
A setting
B setting
Asetting
B setting
No use of Watchdog
A setting
B setting
No.2
No.3
No.4
2-4
Power terminal
RS-232C communication speed is not fast so it takes long time to transmit project data into XGT Panel.
Project data can be quickly transmitted through Ethernet.
When LAN system is configured like the following figure, you can use it easily and effectively.
LAN
In case that LAN system is not configured, it provides 1:1 connection. (LAN cable should be cross cable.)
Ethernet
2-5
Remark
1) We recommend Ethernet more than RS-232C.
2) For the Ethernet cable manufacture, please refer to the communication manual.
3) For the project transmission method, please refer to the XP-Builder manual.
4) Ethernet is not supported on XP30-BTE
2-6
Category
Standard
Related standard
Ambient
operating
temperature
0+50
Storage
temperature
-20+60
Operating
humidity
1085%RH, non-condensing.
Storage
humidity
1085%RH, non-condensing.
Occasional vibration
Vibration
resistance
count
Frequency
Acceleration
Amplitude
5 f < 9
3.5 mm
9 f 150
9.8
Continuous vibration
Shock
endurance
Noise Immunity
X, Y, Z axis
Frequency
Acceleration
Amplitude
5 f < 9
1.75 mm
9 f 150
4.9
IEC 61131-2
* Duration time: 11
* Pulse wave: half sine pulse (3 shocks per axis, on X, Y, Z axis)
LSIS
Square wave
Impulse noise
AC: 1,500V
DC: 1,000V
Electrostatic
discharge Immunity
IEC 61131-2
IEC 61000-4-2
Radiated
electromagnetic
field noise
IEC 61131-2
IEC 61000-4-3
Category
Power module
Voltage
2 kV
Standard
Atmosphere
Altitude
10
Pollution degree
Less than 2
11
Cooling method
Air-cooling
1 kV
IEC 61000-4-4
3-1
Remark
(1) IEC(International Electrotechnical Commission)
: International private group facilitating international cooperation of electric/electronic standardization, issuing international
standards and operating the compliance evaluation systems.
(2) Pollution degree
: As an index representing the pollution degree of an environment to determine the insulation of a device, pollution degree 2
generally means the status generating non-conductive contamination. However, it also contains the status generating
temporarily conduction due to condensation.
(3) Radiated electromagnetic field noise for XP30-BTE is 80 ~ 1000MHz, 10 V/m (All others are same as shown on the table)
XP30-TTA/DC
Screen size
14 (5.7)
Display Resolution
Color indication
65,000 Color
Indication degree
Left/Right: 45 deg.
Upper: 40 deg.
Lower: 20 deg
Backlight
Left/Right: 70 deg.
Upper: 50 deg.
Lower: 70 deg.
CCFL (concluding LCD),
Supporting automatic On/Off
Backlight duration
50,000 hr.
60,000
Contrast
Brightness
230cd/
400cd/
Touch panel
Sound Output
Magnetic buzzer
Process
Graphic accelerator
Hardware Accelerator
Memory
3-2
Medium series
XP30-BTA/DC
XP30-BTE/DC
Flash
Operating RAM
Backup RAM
16MB
32MB
128KB
32MB
64MB
512KB
Backup data
Battery duration
Ethernet
USB Host
1 Channel
RS-232C
Terminal Block
Item
RS-422/485
CF Card
Expansion module
XP30-BTE/DC
Terminal Block
-
Medium series
XP30-BTA/DC
XP30-TTA/DC
1 Channel,RS-422/485 mode
1 Slot (Compact Flash)
Option module is available
Multi-language
Up to 4 language simultaneously
Animation
Recipe
available
Data logging
available
Script executor
available
Certifications
Protection standard
IP65F
Dimension (mm)
Panel cut (mm)
Rated voltage
8.5
Weight(Kg)
0.62
0.75
Large Series
XP70-TTA/DC
XP50-TTA/DC
Display type
Screen size
Display Resolution
26 (10.4)
31(12.1)
Color indication
Indication degree
XP80-TTA/DC
Left/Right: 65 deg.
Upper: 50 deg.
Lower: 60 deg.
Left/Right: 65 deg.
Upper: 45 deg.
Lower: 65 deg.
Left/Right: 65 deg.
Upper: 45 deg.
Lower: 75 deg.
Backlight
Backlight duration
50,000 hr.
Brightness
480cd/
430cd/
8 Line, analog
Sound Output
Magnetic buzzer
Process
Graphic accelerator
Hardware Accelerator
Memory
Touch panel
Flash
Operating RAM
Backup RAM
400cd/
32MB
64MB
512KB
Backup data
Battery duration
Ethernet
Item
XP50-TTA/DC
Large Series
XP70-TTA/DC
XP80-TTA/DC
USB Host
RS-232C
2 Channels
RS-422/485
CF Card
Expansion module
Multi-language
Up to 4 language simultaneously
Animation
Recipe
available
Data logging
available
Script executor
available
Certifications
Protection standard
Dimension (mm)
Panel cut (mm)
IP65F
240 x 174 x 73
228.5 x 158.5
Rated voltage
317 x 243 x 73
294.5 x 227.5
DC24V (Actual Range: 19.2 ~ 28.8V)
20
27
30
Weight(Kg)
1.4
2.2
2.4
Remark
(1) Notice in connecting with power
: Connecting AC power to the device using DC power may cause product break or fire. Be careful when connecting
(2) FG connection
: Use FG terminal (Chapter 2.1) for FG of the device. FG (Chapter 2.1) is for FG terminal of extension card.
(Except XP30-BTE)
(3) Prevention tape of Battery discharge
: There is prevention tape is to prevent the battery discharge. In order to use backup, remove the prevention tape.
(4) Battery operation and duration
: Battery is used to reserve backup data and RTC (data/time) when power is off.
Because battery is used when power is off, battery is not consumed when power is on.
(5) LCD Backlight replacement
: In XP50-TTA/DC, XP70-TTA/DC, XP80-TTA/DC, LCD backlight is replaceable.
However in XP30-BTE/DC, XP30-BTA/DC and XP30-TTA/DC, LCD backlight is not replaceable because
LCD and backlight is all-in-one type.
3-4
AC Type
Item
Large Series
XP80-TTA/AC
XP70-TTA/AC
Display type
XP90-TTA/AC
Screen size
26cm (10.4)
31cm (12.1)
38cm (15)
Display Resolution
Color indication
Indication degree
Backlight
Backlight Duration
Contrast
Brightness
65,000 Color
Left/Right: 65 deg.
Left/Right: 65 deg.
Left/Right: 75 deg
Upper : 45 deg.
Upper : 45 deg.
Upper : 50 deg
Lower : 65 deg.
Lower : 75 deg.
Lower : 60 deg
CCFL (Replacement is available), Supporting automatic On/Off
50,000 hr.
430cd/
400cd/
450cd/
Touch Panel
8 Line, analog
Sound Output
Magnetic buzzer
Process
Graphic Accelerator
Flash
Operating Ram
Backup Ram
Hardware Accelerator
32MB
64MB
Memory
2.
64MB
128MB
512KB
Backup data
Battery duration
Ethernet
USB Host
RS-232C
RS-422/485
CF Card
Expansion Module
Multi-language
Animation
Recipe
Data logging
Script executor
available
Certification
Protection standard
Dimension (mm)
Panel cut (mm)
Rated voltage
Power consumption (W)
Weight (Kg)
395 x 294 x 73
383.5 x 282.5
AC100~240V
40
2.4
46
3.9
3-5
3-6
4-1
Against no use for long time through XGT Panel, you can set Automatically turn off backlight function.
Set whether you use backlight automation On/Off function or not and time, then press OK button as follows.
As above, if you input 30, the backlight automatically turns off after 30 minute later. In off status, if you touch the panel, the backlight turns on.
4-2
Remark
You can set data/time at device information of communication dialog at the XP-Builder.
For details, please refer to the XP-Builders manual.
Remark
The condition is set as the above. No other setting is required. But in case of changing RS-232Cs communication speed, change
as above.
4-3
You can change IP address by pressing [Set] button of each IP address, Subnet Mask and Gateway. By pressing OK button, changed IP
information is reserved.
Remark
We recommend the following method, when connecting with PC solely.
1) XGT Panel setting
- IP Address : 192.168.0.10
- Subnet Mask: 255.255.255.0
- Gateway
: 192.168.0.1
2) PC setting
- IP Address : 192.168.0.11
- Subnet Mask: 255.255.255.0
- Gateway
: 192.168.0.1
4-4
UP button increase Contrast, DOWN button decrease Contrast. Contrast value is between 0~100.
Adjustment is only available for mono type XP30-BTA.(BTE)
Adjustment is available during operation.
If you press the screen for 3 second,
shows up. You can adjust contrast by pressing
button.
When setting [Auto Goto Screen], XGT Panel is rebooted. Or when downloading the edit data is completed, the screen automatically shows
up. If you cancel this setting, the user should press Start button in order to move to the screen.
If you select [Quick Start], when starting screen, screen shows promptly without showing progress bar because it doesnt caching the image
in advance. However, if you select this option, first screen shows slowly. Especially, if there are many animation object in screen, it may takes
several seconds based on image. But fast screen switching is available since second screen switching.
If you select [Hide Mouse Cursor], mouse cursor doesnt show after screen switching
You can set whether you use buzzer through [Buzzer On/Off] button.
4-5
4-6
Chapter 5. Diagnostics
Chapter 5. Diagnostics
It describes the diagnosis function for XGT Panels communication terminal, screen and touch function.
If you press [Diagnostics] button on the XGT Panels basic screen, the menu for diagnosis shows up.
Item
Display
XP30-BTE/DC
XP30-BTA/DC
XP30-TTA/DC
XP50-TTA/DC
XP70-TTA/AC(DC)
XP80-TTA/AC(DC)
XP90-TTA/AC
5-1
Chapter 5. Diagnostics
If the touched location is not correct, reset the Touch setting. For detailed information, please refer to the Chapter 4. System Configuration.
Remark
(1) If NVRAM Data Access Fail error is occurred, please contact with customer service center.
(2) If BATTERY STATUS BAD error is occurred, battery should be changed. Please contact with Customer service
center.
5-2
Chapter 5. Diagnostics
Remark
If Read Disk Information Error! occurs, please contact with Customer service center.
Remark
If Read Disk Information Error! occurs, please contact with Customer service center.
CF Card is not supported on XP30-BTE.
5-3
Chapter 5. Diagnostics
The followed feature is Loop Back terminal. In case of communication diagnosis, connect as followed feature.
The tool port terminal should be made as follows. (Connect the No.2 and 6 pin)
The RS-232C port terminal should be made as follows. (Connect the No.2 and 3 pin)
5-4
Chapter 5. Diagnostics
The RS-422/485 port terminal should be made as follows. (Connect the Pin No.4 with 8 and Pin No. 5 with 9)
5-5
[Method]
(a) Select [PLC Information] in the menu.
(b) Select the designated PLC. The listed PLC is the same as connection number which is set at [Common - Project Property Setting
PLC/Device settings] in XP-Builder.
6-1
Remark
The following PLC is available for view of PLC information.
- MASTER-K CPU, FEnet, Cnet
- GLOFA-GM CPU, FEnet, Cnet
- XGK/XGB/XGI CPU, FEnet, Cnet
6-2
Remark
The following PLC is available for viewing Error History.
- MASTER-K CPU doesnt have the Error History.
- GLOFA-GM CPU
- XGK/XGI CPU
- XGB CPU doesnt have the Error History.
Remark
The following PLC is available for viewing PLC operation mode conversion history.
- MASTER-K CPU doesnt have the history about operation mode conversion.
- GLOFA-GM CPU
- XGK/XGI CPU
- XGB CPU doesnt have the history about operation mode conversion.
6-3
You can check the history about when PLC was turned on and off
Remark
The following PLC is available for viewing the history of when our PLC was turned off and on.
- MASTER-K CPU doesnt have the history about when our PLC was turned on and off.
- GLOFA-GM CPU
- XGK/XGI CPU
- XGB CPU doesnt have the history about when our PLC was turned on and off.
Remark
The following PLC is available for viewing history about system..
- MASTER-K CPU doesnt have the history about system.
- Only GLOFA-GM CPU (GM4C) has the history about system. Other CPUs dont have the history about system.
- XGK/XGI CPU
- XGB CPU doesnt have the history about system.
6-4
Remark
-
For further information about the settings, please refer to the PLC user manual.
[Program Monitor] button is activated in case of LSIS PLC Direct Driver
6-5
2. In case of downloading the project by using CF card or USB storage equipment, touch [Project Download] button.
3. In case of transmitting the project data stored in the device to CF card or USB storage equipment, touch [Project Upload] button.
4. In case of updating the XGT Panel with XGT Panel Software stored in CF card or USB Storage equipment, touch [XGTPanel
Update]
7-1
2. In case of selecting [USB], the directory list under the path, \USB Storage\XP_Project\ shows. In case of selecting [CF], the
directory list under the path, \Storage Card\XP_Project\ shows. In case of downloading the project by using storage equipment,
the project should be saved in the one lower directory between those two directories.
3. Select one among directory lists and touch [OK]. Then downloading will start.
2. In case of selecting [USB], the path, \USB Storage\XP_Backup\, shows. In case of selecting [CF], the path, \Storage
Card\XP_Backup\, shows. Select one between two.
3. If you touch [OK] button, project backup file is transmitted to the selected path.
4. The project backup file is saved when Download project backup file is selected when downloading the project.
If you dont select, project backup file is not saved in the device and transmission to the storage equipment is not available.
7-2
2. In case of selecting [USB], the directory list under the path, \USB Storage\XP_Project\ shows. In case of selecting [CF], the
directory list under the path, \Storage Card\XP_Project\ shows. In case of updating the device by using storage equipment, the
XGTPanel Softwareproject should be saved in the one lower directory between those two directories.
3. If you touch [OK] button, the device is updated with XGTPanel Software in the designated path.
Notice
(1) Do not remove USB storage equipment or turn off the device during operation. It may cause abnormal installation of
project data.
(2) Do not remove or move the directory except CF or USB storage equipment. It may cause abnormal operation.
7-3
After downloading XGT Panel software from LSIS website, make a temporary folder and save it.
Designate the folder where the software will be saved in the XP-Builders [XGT Panel Update] windows and update XGT Panel by
[Send] menu. For more detailed information about XP-Builder, please refer to the XP-Builder user manual.
Remark
Do not remove communication cable or turn off the device during updating. It may cause the malfunction.
8-1
9-1
9-3
In order to use this monitoring function, you have to set about system alarm window
9-4
In case USB storage equipment (or CF storage equipment) is removed during operation after setting the path for saving Logging backup
file as USB storage equipment (or CF storage equipment) and downloading the project into device, the designated system alarm
(HS951.0) is set. In case storage equipment is equipped again, alarm is reset.
In case USB storage equipment (or CF storage equipment) is removed during operation after setting the path for saving Recipe backup
file as USB storage equipment (or CF storage equipment) and downloading the project into device, the designated system alarm
(HS951.1) is set. In case storage equipment is equipped again, alarm is reset.
In case USB storage equipment (or CF storage equipment) is removed during operation after setting the path for saving ScreenImage
backup file as USB storage equipment (or CF storage equipment) and downloading the project into device, the designated system alarm
(HS951.2) is set. In case storage equipment is equipped again, alarm is reset.
Internal address of the designated system alarm can be checked in XP-Builder as follows.
9-5
Remark
Anti-water and anti-vibration standard
IP standard is IEC 529 standard (international anti-water grade regulation) and it can be divided into protection grade against
invasion of solid matter and protection grade against invasion of water.
In the IP65 certification, it can be divided into protection against dust (6) and water jets from all sides (5).
IP20 is about protection against solid matter (2) whose diameter is more than 12mm and IP2 doesnt have protection about water
(0))
10-1
Classification
XP30-BTE
XP30-BTA
XP30-TTA
X (Wide)
1
156.0
XP50-TTA
228.5
XP70-TTA
294.5
XP80-TTA
294.5
383.5
XP90-TTA
0
1
0
1
0
+1
-0
1
0
Y (Height)
1
123.5
0
158.5
227.5
227.5
282.5
1.6~9.5
+1
-0
1
0
10-2
1
0
1
0
Unit: [mm]
Z (Thickness)
100
100
100
100
100
Remark
(1) To be affected at a minimum by the electromagnetic waves (radial noise) or heat from other controllers, it needs to keep its
distance as the above explanation.
(2) When installing, consider the power and communication cable wiring.
When fixing the product to panel, use the anti-vibration rubber packing.
The anti-vibration rubber packing is equipped at the XGT Panel basically.
Anti-vibration
rubber packing
Remark
Because the product can be affected by dust, use the anti-vibration rubber packing.
10-3
Upper
Lower
XP30-BTE
45 deg.
40 deg.
20 deg.
XP30-BTA
45 deg.
40 deg.
20 deg.
XP30-TTA
70 deg.
50 deg.
70 deg.
XP50-TTA
65 deg.
50 deg.
60 deg.
XP70-TTA
65 deg.
45 deg.
65 deg.
XP80-TTA
65 deg.
45 deg.
75 deg.
XP90-TTA
75 deg.
50 deg.
60 deg.
Remark
1) Because XP30-BTA (BTE) uses STN Mono LCD, it has poorer clearness and expression angle.
2) XP30-BTA (BTE) can adjust Contrast. Adjust Contrast according to environment.
(4) Fixation
Fix the XGT by using the bracket as follows. (The bracket is included in the product.)
Fix through
Panel
bracket
Fix through
bracket
Fix through
bracket
Fix through
bracket
10-4
10.2 Wiring
It describes the wiring that you should know when installing the XGT Panel.
Name
XP30-BTE/DC
XP30-BTA/DC
XP30-TTA/DC
XP50-TTA/DC
XP70-TTA/DC
XP80-TTA/DC
XP30-BTA/D1
XP50-TTA/D1
XP70-TTA/AC
XP80-TTA/AC
XP90-TTA/AC
DC 24V
DC 12~24V
AC 100~240V
Remark
(1) If AC power is applied into the product for DC power, It may cause damage or fire. Be careful of connection.
(2) /DC is the product which use DC 24V, /D1 is the product which use DC 12~24V, and
/AC is the product which use AC 100~240V. When using the product, check the label in the back of the product.
The power terminal should have the following specification.
3.2
3.2
Less than
Less than
6.00mm
6.00mm
Remark
(1) Because of voltage down, we recommend the thick stranded cable (more than 2 ).
(2) If possible, use the stranded cable and connect with minimum length.
(3) To easily classify the cable, use the different colors cable respectively.
10-5
Ground
DC Power connection
AC Power
100~220 V
Ground
AC 100~240V
AC power connection
Remark
(1) When the regulation of power is bigger than provision, use the constant voltage transformer.
(2) In case power has much noise, use the insulation transformer.
10-6
Constant
Voltage
Transformer
I/O power
I/O device
XGT Panel
E1
E2
Remark
(1) Separate the surge absorbers ground (E1) from XGT Panels ground (E2).
(2) Select a surge absorber so as not to exceed the maximum permissible voltage of a surge absorber even if power
voltage rises to maximum
When noise invades, use the insulation shield trans or noise filter.
Strand input power cable with minimum length and make sure the shield trans or noise filter is not crossed above the duct.
10-7
The other
devices
Type 3 ground
XGT
Panel
The other
devices
XGT
Panel
The other
devices
Type 3 ground
(4) Use the cable more than 2 mm2. Put the point of the ground near the XGT Panel and shorten the ground line.
Remark
If the ground status is poor or connected like C), it may cause malfunction or fault of communication.
Make sure that the ground status is good.
10-8
11.1 Maintenance
Because an error may be developed by environment, the periodic maintenance is needed. You should check the following categories once
or twice every 6 months.
Maintenance category
Power
Operating
temperature
Environment
Judgment standard
Operating
humidity
Vibration
Measure
Modify the source of electric power in order to be in the
fluctuation range of a permissible voltage.
0 ~ + 50
Modify the operating temperature and humidity to be proper.
10 ~ 85%RH
No vibration
There is no unwinding
There is no unwinding
reservation
Maintenance contents
connector
Indication LED
Measure
Fixed firmly
There is no unwinding
Correction
There is no unwinding
Status of communication
Judgment standard
Refer to the
appendix 1.
11-1
Maintenance method
Surrounding
temperature
0 ~ 50 C
Measure through
temperature/Hygrometer
Surrounding pollution
10 ~ 85%RH
There is no corrosive gas.
degree
Measure
Modify it to meet the general
standard.
(environment standard in the
panel)
Fixed firmly
Check by eye
There is no adhesion
There is no unwinding.
Check by eye
Correction
Check by eye
There is no unwinding.
Battery
Checking by eye
XGT Panel
Status
Unwinding, swing
Judgment standard
between compressed
terminals.
Unwinding of connector
Touch
status
11-2
There is no damage or
scratch/pollution
touch pad.
Remark
(1) Battery exchange time is expressed by alarm. System alarm is expressed when system alarm category is set at the XP-Builder
as follows.
(2) LCD backlights exchange is available for only XP50-TTA, XP70-TTA, XP80-TTA, XP90-TTA. In case of XP30-BTE, XP30BTA, XP30-TTA, you have to exchange the LCD when error occurs or product life is finished because LCD and backlight is one
product.
11-3
Result
1. Emission
Conducted emission
EN61000-6-4:2001
Radiated emission
EN61000-6-4:2001
EN61000-3-2:2000
EN61000-3-3:1995+A1:2001
NARE2)
NT RE3)
RE2)
NA
RE3)
NT
2. Immunity
Electrostatic discharge
Fast transient
Radio-frequency amplitude modulated electromagnetic field
(80-1000MHz)
Radio-frequency common mode
Surges
Voltage dips and interruptions
EN61000-6-2:2001
(EN61000-42:1995+A1:1998+A2:2001)
EN61000-6-2:2001
(EN61000-4-4:2004)
EN61000-6-2:2001
(EN61000-4-3:2002)
EN61000-6-2:2001
(EN61000-4-6:1996+A1:2001)
EN61000-6-2:2001
(EN61000-4-5:1995+A1:2001)
EN61000-6-2:2001
(EN61000-4-11:1994+A1:2001)
C
C
C
C
RE2)
NA
C RE3)
RE1) C=Conform
NC=Not Conform NT=Not Tested
NA=Not Applicable
RE2) Applicable to the only XP30-BTE/DC, XP30-BTA/DC, XP30-TTA/DC, XP50-TTA/DC, XP70-TTA/DC, XP80-TTA/DC
RE3) Applicable to the only XP70-TTA/AC, XP80-TTA/AC, XP90-TTA/AC
Directive:
Electromagnetic Compatibility Directive 89/336/EEC amended by the Directive 93/68/EEC
12-1
A grade device
This device acquires KCC for business. Be careful that.
If device is not purchased properly, exchange it to device for home.
12-2
Appendix 1. Troubleshooting
Appendix 1. Troubleshooting
1. Type of Problem
It classifies problems from XGT Panel including an indicated figure, indication of the object, and problems appeared when
downloading. Refer to the following chart.
Classification of problem
Description
Communication problem
In case that an error message occurs when operating the XGT Panel.
Please refer to the 6. Error message when executing program.
Contents
Communication time-out or system alarm which is registered as a system alarm at
the builder occurs in the HMI. (It is not recovered)
OS booting status, HMIs monitoring status, HMIs not monitoring status.
(including image data, diagnosis, setting , and engine update)
App.1-1
Appendix 1. Troubleshooting
Phenomenon. When touching the screen it reacts in a different area or it may not react at all.
<Reason>
1) Touchs Calibration setting is not proper.
2) Touch panel may be a break down.
<Solution>
1) Redo Calibration setting about touch. Refer to the [Device manual Ch.4.1 Touch Calibration].
2) It you cant go to setting menu, connect mouse to USB port and use mouse.
Buzzer does not sound.
Phenomenon
The switch is expressed but it doesnt work.
The switch is expressed but it doesnt work.
The switch is expressed but it doesnt work.
The switch is expressed but it doesnt work.
The switch is expressed but it doesnt work.
Image is not shown.
Image is not shown.
Appendix 1. Troubleshooting
Object type
N-State Lamp
Clock
Bit Message
Word Message
Numeric Display
Numeric input
Text Display
Text Input
Bit Window
Word Window
Bit Part
Word Part
Animation
Bar Graph
Pie Graph
Meter Graph
Closed Graph
Trend Graph
History Alarm Viewer
Datalist
Logging Viewer
Navigator
Phenomenon
Image is not shown.
Present time is shown.
Message is not shown. When designating the background image, image is shown as it is.
Message is not shown. When designating the background image, image is shown as it is.
The value is not shown. When designating the background image, image is shown as it is.
The value is not shown. When designating the background image, image is shown as it is.
Character string is not shown. When designating the background image, image is shown as it is.
Character string is not shown. When designating the background image, image is shown as it is.
The window screen set in the object is not shown. But if communication is set with other object in
the same window screen, it can be shown by that object.
The window screen set in the object is not shown. But if communication is set with other object in
the same window screen, it can be shown by that object.
The part screen set in the object is not shown. But if communication is set with other object in the
same part screen, it can be shown by that object.
The part screen set in the object is not shown. But if communication is set with other object in the
same part screen, it can be shown by that object.
Animation is not shown.
Graph is not shown. When designating the background image, image is shown as it is.
Graph is not shown. When designating the background image, image is shown as it is..
Graph is not shown. When designating the background image, image is shown as it is.
Graph is not shown. When designating the background image, image is shown as it is.
X, Y axis is shown normally but trend axis is not normally shown. When designating the
background image, image is shown as it is.
Change doesnt occur. When communication is abnormal, alarm occurs because it cant know
the status of alarm target device. But previous alarm data shows up as it is.
Value is not shown. Lattice of viewing data list of object is shown as it is.
Change doesnt occur. When communication is normal, the recorded log data is shown normally.
But, log data is shown as # when communication is abnormal.
Change doesnt occur. Because it shows the group of alarm already developed, though
communication is abnormal, if it has alarm data already developed, it shows the name of group
where each alarm is included.
App.1-3
Appendix 1. Troubleshooting
After switching the screen, the previous screen remains for a few minute.
Phenomenon. After switching the screen, when there is no background or image in the part or number indication device, the
previous screen remains for a few minute because of change of part.
<Reason>
After switching the screen, when connection is set up multiply or communication time-out occurs, the screen of previous part
remains in some object.
<Solution>
1) Its normal status. In case that multiple connection or communication is not good, when switching the screen, the remains
of previous screen can occur during the time-out hour.
The folded object doesnt sequentially show up.
Phenomenon. The number under the data list shows up above data list.
<Reason>
1) The device value is expressed at the top of object screen.
<Solution>
1) Its normal status. The folded window or part object is not included in screen, regardless of sequence of drawing, the
object changed recently is expressed at top of screen. So if possible, do not fold the object in screen.
App.1-4
Appendix 1. Troubleshooting
5. Communication Problem
It seems that communication does not work.
Phenomenon. On the screen where the object is not many, communication works but when you move the screen where the
object is many, timeout occurs.
<Reason>
1) In the device setting, the communication time-out is set to be too short.
<Solution>
1) It occurs because timeout is set much smaller than sum of request time of communication data and response time from
PLC. In the device setting at the XP-Builder, after setting communication time out to be big, download program and
execute again.
It seems that communication doesnt work.
Phenomenon. Communication doesnt work.
<Reason>
1) Communication setting or cable may be not normal.
<Solution>
1) In case of RS-232C, check whether connection setting is normal or not in XP-Builder.
2) In case of RS-422/485, check whether station and communication connection setting is normal or not.
3) If 1), 2) is normal, do diagnosis about PLC-RS232C, PLC-RS485/422 at the Serial diagnosis screen of device menu.
Refer to the [Device manual ch.5.6 Serial Communication Diagnosis]
4) If 3) is normal, check whether connection cable has error or not.
5) In case of Ethernet, check the port and IP setting about relative PLC.
App.1-5
Appendix 1. Troubleshooting
App.1-6
Appendix 1. Troubleshooting
Address
Device
setting
0x01
0x02
Error message
0x01
XGT
Panel
0x02
XGT
Panel
0x03
Device
diagnosis
Occurrence
location
0x04
XGT
Panel
XGT
Panel
0x05
XGT
Panel
0x06
XGT
Panel
0x01
XGT
Panel
0x02
XGT
Panel
0x03
XGT
Panel
Viewing
device
information
0x03
0x01
XGT
Panel
XGT Panel
Update
0x04
0x01
XGT
Panel
Switch
h05
h01
XGT
Panel
Invalid password.
App.1-7
Appendix 1. Troubleshooting
Error code
Object
Type
Number
indication
device/
Number
input device
Address
Occurrence
location
Error message
h01
XGT
Panel
h02
XGT
Panel
No input Data.
0x03
0x06
0x04
0x05
0x06
XGT
Panel
XGT
Panel
XGT
Panel
XGT
Panel
Lamp
0x07
None
Character
indication
device/
Character
input device
0x08
None
Message
0x09
None
Clock
0x0A
None
Animation
0x0B
None
Graph
0x0C
None
Window
0x0D
None
Part
0x0E
None
History alarm
0x0F
None
Flow alarm
0x20
None
0x21
None
0x22
None
0x23
None
0x24
None
0x25
None
System
alarm
Scheduler
related
Recipe
related
Logging
related
Data list
App.1-8
Appendix 1. Troubleshooting
Error code
Object
Type
Address
0x00
0x01
0x02
0x03
0x04
Project
download
Occurrence
location
Error message
Abnormal send-payload.
Please download project
again.
XP Builder
XP Builder
XGT
Panel
XP Builder
XP Builder
XP Builder
XP Builder
0x26
0x05
0x06
0x07
0x08
XP Builder
XP Builder
App.1-9
Appendix 1. Troubleshooting
Error code
Object
Type
Project
download
0x26
Address
Error message
0x09
XP Builder
0x0A
XP Builder
0x0B
XP Builder
0x0C
XGT
Panel
0x0D
XGT
Panel
0x0E
XGT
Panel
0x0F
XGT
Panel
There's no downloaded
project. It needs to download
whole project
0x10
App.1-10
Occurrence
location
XP Builder
Appendix 1. Troubleshooting
Error code
Object
Type
Address
0x11
Project
download
0x26
Occurrence
location
XGT
Panel
Error message
0x12
XGT
Panel
0x15
XGT
Panel
0x16
XGT
Panel
0x17
XGT
Panel
0x18
XGT
Panel
0x19
XGT
Panel
Failed to unmarshall
download file. Please
download project again.
0x1A
XGT
Panel
0x1B
XGT
Panel
App.1-11
Appendix 1. Troubleshooting
Error code
Object
Type
Project
download
Project
download
from USB
storage
device
App.1-12
Address
Error message
0x1C
XGT
Panel
0x1D
XGT
Panel
0x1E
XGT
Panel
0x1F
XGT
Panel/
XP-Builder
0x51
XGT
Panel
0x52
XGT
Panel
0x53
XGT
Panel
0x26
0x27
Occurrence
location
0x54
XGT
Panel
0x55
XGT
Panel
Appendix 1. Troubleshooting
Error code
Object
Type
Address
0x56
Project
download
from USB
storage
device
0x27
Occurrence
location
XGT
Panel
Error message
0x57
XGT
Panel
0x58
XGT
Panel
0x58
XGT
Panel
0x59
XGT
Panel
0x5A
XGT
Panel
0x5A
XGT
Panel
0x5B
XGT
Panel
0x5C
XGT
Panel
0x5D
XGT
Panel
App.1-13
Appendix 1. Troubleshooting
Error code
Object
Type
Project
download
from USB
storage
device
App.1-14
Address
Occurrence
location
Error message
0x5E
XGT
Panel
0x5F
XGT
Panel
0x60
XGT
Panel
0x61
XGT
Panel
0x62
XGT
Panel
0x63
XGT
Panel
0x64
XGT
Panel
Cannot unmarshall
download file.
0x65
XGT
Panel
0x66
XGT
Panel
0x67
XGT
Panel
0x68
XGT
Panel
0x27
Appendix 1. Troubleshooting
Error code
Object
Type
Address
0x01
0x02
0x03
0x04
XGT Panel
booting
Occurrence
location
XGT
Panel
XGT
Panel
XGT
Panel
XGT
Panel
Error message
Failed to rename
UpdateNew.exe
0x28
0x05
0x29
XGT
Panel
0x06
XGT
Panel
0x30
XGT
Panel
App.1-15
Appendix 1. Troubleshooting
Error code
Occurrence
location
Error message
0x31
XGT
Panel
Password-related command
transmission payload error
0x32
XGT
Panel
0x33
XGT
Panel
0x34
XGT
Panel
0x21
XGT
Panel/
XP-Builder
0x22
XGT
Panel/
XP-Builder
0x23
XGT
Panel/
XP-Builder
Object
Type
Communicati
on between
other XP
BuilderXGT Panel
XGT panel
S/W update
Address
0x30
0x24
0x25
0x30
App.1-16
0x26
XP-Builder
XP-Builder
XGT
Panel
Appendix 1. Troubleshooting
Error code
Object
Type
Address
Occurrence
location
Error message
XGT panel
S/W update
0x27
0x28
XGT
Panel
0x2A
XGT
Panel
(improper communication
command)
Current state is not
authorized.
(improper communication
command)
Modules to download is not
listed up yet.
0x2C
0x30
0x2B
XGT panel
S/W update
XGT
Panel
0x2D
XGT
Panel
XGT
Panel
XGT
Panel
App.1-17
Appendix 1. Troubleshooting
Error code
Object
Type
Address
0x2E
App.1-18
Occurrence
location
XGT
Panel
Error message
Appendix 2. Dimension
App.2-1
Appendix 2. Dimension
(3) XP50-TTA/DC
App.2-2
Appendix 2. Dimension
(5) XP80-TTA/AC, XP80-TTA/DC
(6) XP90-TTA/AC
App.2-3
Warranty
1. Warranty Period
The product you purchased will be guaranteed for 18 months from the date of manufacturing.
2. Scope of Warranty
Any trouble or defect occurring for the above-mentioned period will be partially replaced or repaired. However, please note the
following cases will be excluded from the scope of warranty.
Any trouble attributable to unreasonable condition, environment or handling otherwise specified in the manual,
Any trouble attributable to others products,
If the product is modified or repaired in any other place not designated by the company,
Due to unintended purposes
Owing to the reasons unexpected at the level of the contemporary science and technology when delivered.
Not attributable to the company; for instance, natural disasters or fire
3. Since the above warranty is limited to HMI unit only, make sure to use the product considering the safety for system
configuration or applications.
Environmental Policy
LS Industrial Systems Co.,Ltd supports and observes the environmental policy as below.
Environmental Management
LS Industrial Systems considers the
environmental preservation as the preferential
management subject and every staff of LS
Industrial Systems use the reasonable
endeavors for the pleasurably environmental
preservation of the earth.
About Disposal
LS Industrial Systems PLC unit is designed
to protect the environment. For the disposal,
separate aluminum, iron and synthetic resin
(cover) from the product as they are
reusable.
http://eng.lsis.biz
10310000867
HEAD OFFICE
LS tower, Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do
1026-6, Korea http://eng.lsis.biz
e-mail: [email protected]
Tel. (82-2)2034-4689, 4888
Fax.(82-2)2034-4648
LS Industrial Systems Tokyo Office >> Japan
Address: 16F, Higashi-Kan, Akasaka Twin Towers 17- 22,
2-chome, Akasaka, Minato-ku, Tokyo 107-8470, Japan
Tel: 81-3-3582-9128
Fax: 81-3-3582-2667
e-mail: [email protected]
LS Industrial Systems Dubai Rep. Office >> UAE
Address: P.O.BOX-114216, API World Tower, 303B, Sheikh
Zayed road, Dubai, UAE.
e-mail: [email protected]
Tel: 971-4-3328289 Fax: 971-4-3329444
LS-VINA Industrial Systems Co., Ltd. >> Vietnam
Address: LSIS VINA Congty che tao may dien Viet-Hung
Dong Anh Hanoi, Vietnam
e-mail: [email protected]
Tel: 84-4-882-0222 Fax: 84-4-882-0220
LS Industrial Systems Hanoi Office >> Vietnam
Address: Room C21, 5th Floor, Horison Hotel, 40 Cat Linh,
Hanoi, Vietnam
Tel: 84-4-736-6270/1 Fax: 84-4-736-6269
Dalian LS Industrial Systems co., Ltd, >> China
Address: No. 15 Liaohexi 3 Road, economic and technical
development zone, Dalian, China
e-mail: [email protected]
Tel: 86-411-8273-7777
Fax: 86-411-8730-7560
Fax: 86-532-583-3793
2009. 10