ADEC™ - Error List - 2006 - MTU® PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 33
At a glance
Powered by AI
The document lists various error codes and their descriptions related to an engine control unit.

Some of the errors listed include high fuel temperature, high charge air temperature, low lube oil pressure, high exhaust gas temperature, and engine overspeed.

The alarm configuration parameters and their details can be found in PR 2.8008.100.

ECU7 Software

ADEC Error List


2006-11-16
sorted by No. and ZKP-No.

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

FSW-No:

2_1_1_1_11_0 / 2_2_33_1_1_0

Application:

Universal / All Applications

Generated:

2006-11-16

Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
1 von 33

ECU7 Software

No.

ZKP-No.

Name

2.0122.931

HI T-Fuel

2.0122.932

SS T-Fuel

2.0121.931

HI T-Charge Air

2.0121.932

SS T-Charge Air

2.0124.931

HI T-Coolant Intercooler

10

2.0124.932

SS T-Coolant Intercooler

15

2.0100.921

LO P-Lube Oil

16

2.0100.922

SS P-Lube Oil

19

2.0126.931

HI T-Exhaust A

20

2.0126.932

SS T-Exhaust A

21

2.0127.931

HI T-Exhaust B

22

2.0127.932

SS T-Exhaust B

23

2.0152.921

LO Coolant Level

25

2.0154.931

HI P-Diff-Lube Oil

26

2.0154.932

SS P-Diff-Lube Oil

27

2.0151.931

HI Level Leakage Fuel

29

1.8004.206

HI ETC Idle Speed too High

30

2.2510.932

SS Engine Overspeed

31

2.3011.931

HI ETC1 Overspeed

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
Fuel temperature too high (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Fuel temperature too high (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Charge air temperature too high (limit 1) ==> Check InterCooler
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Charge air temperature too high (limit 2) ==> Check InterCooler
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant temperature of InterCooler too high (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant temperature of InterCooler too high (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Pressure of lube oil too low (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Pressure of lube oil too low (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Exhaust gas temperature (A-side) too high (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Exhaust gas temperature (A-side) too high (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Exhaust gas temperature (B-side) too high (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Exhaust gas temperature (B-side) too high (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant level too low (limit 1) ==> Check coolant level in compensation container
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Differential pressure of oilfilter too high (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Differential pressure of oilfilter too high (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Level of leakage fuel too high (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Idle Speed of one of the switcheable chargers too high.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Engine Overspeed (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Speed of basic charger too high (limit 1).
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
2 von 33

ECU7 Software
No.

ZKP-No.

Name

32

2.3012.932

SS ETC1 Overspeed

36

2.3013.931

HI ETC2 Overspeed

37

2.3013.912

SS ETC2 Overspeed

38

1.8004.205

AL ETC Speed Deviation

39

1.8004.204

AL ETC2 CutIn Failure

44

2.0153.921

LO Coolant Level Intercooler

51

2.0125.931

HI T-Lube Oil

52

2.0125.932

SS T-Lube Oil

57

2.0101.921

LO P-Coolant

58

2.0101.922

SS P-Coolant

59

2.0120.933

SS T-Coolant L3

60

2.0120.934

SS T-Coolant L4

63

2.0106.931

HI P-Crank Case

64

2.0106.932

SS P-Crank Case

65

2.0102.921

LO P-Fuel

66

2.0102.922

SS P-Fuel

67

2.0120.931

HI T-Coolant

68

2.0120.932

SS T-Coolant

81

1.8004.046

AL Rail Leakage

82

2.0104.931

HI P-Fuel (Common Rail)

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Speed of basic charger too high (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Speed of 1st switcheable charger too high (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Speed of 1st switcheable charger too high (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Speed deviation between basic turbo charger and one of the switcheable chargers.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Switching of charger ETC2 failed.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant level of intercooler too low (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Lube oil temperature too high (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Lube oil temperature to high (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant pressure too low (limit 1) ==> check cooling cycle.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant pressure too low (limit 2) ==> Engine stop or limitation of the injection quantity ==> check cooling cycle
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant temperature too high/ too low (limit 3).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant temperature too high/ too low (limit 4).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Crankcase pressure too high (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Crankcase pressure too high (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Fuel supply pressure too low (limit 1) ==> Check filter, fuel on low-pressure side
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Fuel supply pressure too low (limit 2) ==> Check filter (low-pressure side)
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant temperature too high (limit 1) ==> Check circulation of coolant
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant temperature too high (limit 2) ==> Check circulation of coolant
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Rail pressure gradient too low for Start or too high for Stop
(==> High-pressure system leaks, air in the system)
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Rail pressure > setpoint value => DBR reduction, shift of start of injection delayed
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
3 von 33

ECU7 Software
No.

ZKP-No.

83

2.0104.921

85

2.0128.931

86

2.0128.932

89

2.2500.030

90

2.1090.925

91

2.1090.924

92

2.1090.923

93

2.1090.922

94

2.1090.921

95

2.1090.920

102

1.8004.624

104

1.8004.623

118

2.0140.921

119

2.0140.922

120

2.0140.931

121

2.0140.932

122

2.0132.921

176

2.4000.004

Name

Description
(==> interphase transformer sticks or connections of the interphase transformer)
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Rail pressure < setpoint value => DBR reduction
LO P-Fuel (Common Rail)
(==> interphase transformer defective or leakage in high-pressure system)
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Umblasen' temperature too high (limit 1).
HI T-Umblasen
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Umblasen' temperature too high (limit 2).
SS T-Umblasen
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Engine is being stalled. The engine speed of the normally operating engine dropped below the limit from
parameter 2.2500.027 Limit Engine Speed Low without any stop request. For safety reason the engine is
SS Engine Speed too Low
stopped when this event occurs.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Idle speed not reached ==> Start abort ==> pay attention to other messages
SS Idle Speed Not Reached
(Alarm Configuration Parameter, for details see PR 2.8008.100)
SS Release Speed Not
Acceleration speed not reached ==> Start abort ==> observe other messages
Reached
(Alarm Configuration Parameter, for details see PR 2.8008.100)
SS Starter Speed Not
Starter speed not reached ==> Start abort ==> Starter does not turn or turns too slowly
Reached
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Preheat temperature too low (limit 2) ==> Coolant temperature for engine start too low ==> Bolting engine start
SS T-Preheat
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Preheat temperature too low (limit 1) ==> Coolant temperature for engine start too low
LO T-Preheat
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Prelubrication fault.
AL Prelubrication Fault
(Alarm Configuration Parameter, for details see PR 2.8008.100)
AL Fuel Cons. Counter
Fuel consumption counter defect.
Defect
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Engine Hours Counter defect.
AL Eng Hours Counter Defect
(Alarm Configuration Parameter, for details see PR 2.8008.100)
LO ECU Power Supply
Power supply voltage too low (limit 1) ==> Check battery / generator
Voltage
(Alarm Configuration Parameter, for details see PR 2.8008.100)
LOLO ECU Power Supply
Power supply voltage too low (limit 2) ==> Check battery / generator
Voltage
(Alarm Configuration Parameter, for details see PR 2.8008.100)
HI ECU Power Supply
Power supply voltage too high (limit 1) ==> Check battery / generator
Voltage
(Alarm Configuration Parameter, for details see PR 2.8008.100)
HIHI ECU Power Supply
Power supply voltage too high (limit 2) ==> Check battery / generator
Voltage
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Temperature of electronic too high (limit 1).
HI T-ECU
(Alarm Configuration Parameter, for details see PR 2.8008.100)
No (fitting) LifeData-Backup-System is available within a delaytime after ECU-Reset . ==> Backup-system has
AL LifeData not available
no LifeData-function or CAN bus interrupted to Backup-system.

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
4 von 33

ECU7 Software
No.

ZKP-No.

Name

177

2.4000.006

AL LifeData restore
incomplete

180

2.0500.680

AL CAN1 Node Lost

181

2.0500.681

AL CAN2 Node Lost

182

2.0500.682

AL CAN Wrong Parameters

183

2.0500.683

AL CAN No PU-Data

184

2.0500.684

AL CAN PU-Data Flash Error

186

2.0500.686

AL CAN1 Bus Off

187

2.0500.687

AL CAN1 Error Passive

188

2.0500.688

AL CAN2 Bus Off

189

2.0500.689

AL CAN2 Error Passive

190

2.0500.690

AL EMU Parameter Not


Supported

201

1.8004.570

SD T-Coolant

202

1.8004.572

SD T-Fuel

203

1.8004.571

SD T-Charge Air

205

1.8004.574

SD T-Coolant Intercooler

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
(Alarm Configuration Parameter, for details see PR 2.8008.100)
If the ADEC has to restore the LifeData from the backup-system and at least one checksum is wrong after the
upload or the upload is incomplete, then this failure is set.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Connection to a node on CAN bus 1 lost. ==> Check devices connected on CAN
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Connection to a node on CAN bus 2 lost. ==> Check devices connected on CAN
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Incorrect CAN parameter values have been entered.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
A CAN mode is selected which the communication is initialized aided of the PU data module. However,
required PU data module is not present or is not valid.
==> Check the devices connected by CAN
(Alarm Configuration Parameter, for details see PR 2.8008.100)
During attempt to copy a received PU data module to Flash module, a program error occurred. ==> Electronic
service
(Alarm Configuration Parameter, for details see PR 2.8008.100)
CAN Controller 1 is in "Bus Off" state => Automatic switchover to CAN2
==>causes e.g. short circuit, massive interference or baud rate incompatibility
(Alarm Configuration Parameter, for details see PR 2.8008.100)
CAN Controller 1 has signaled a warning. ==> causes e.g. lack of associated nodes, slight interference or
short-term bus overload.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
CAN-Controller 2 is in "Bus Off" state => Automatic switchover to CAN 1 ==>causes e.g. short circuit, massive
interference or baud rate incompatibility.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
CAN Controller 2 has signaled a warning. ==> causes e.g. lack of associated nodes, slight interference or
short-term bus overload.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
EMU parameters are not supported. ==> Incompatibility
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant temperature-sensor defect. ==> short circuit or cable breakage
==> Check sensor and cable (B6), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Fuel temperature-sensor defect. ==> short circuit or cable breakage
==> Check sensor and cable (B33), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Charge air temperature-sensor defect. ==> short circuit or cable breakage
==> Check sensor and cable (B9), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Intercooler coolant temperature-sensor defect. ==> short circuit or cable breakage
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
5 von 33

ECU7 Software
No.

ZKP-No.

Name

206

1.8004.576

SD T-Exhaust A

207

1.8004.577

SD T-Exhaust B

208

1.8004.566

SD P-Charge Air

211

1.8004.563

SD P-Lube Oil

212

1.8004.564

SD P-Coolant

213

1.8004.569

SD P-Coolant Intercooler

214

1.8004.568

SD P-CrankCase

215

1.8004.567

SD P-HD

216

1.8004.575

SD T-Lube Oil

219

1.8004.573

SD T-Intake Air

220

1.8004.584

SD Level Coolant Water

221

1.8004.585

SD P-Diff Lube Oil

222

1.8004.582

SD Level Leakage Fuel

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
==> Check sensor and cable (B26), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Exhaust gas temperature-sensor on A-side defect. ==> short circuit or cable breakage
==> Check sensor and cable (B4.21), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Exhaust gas temperature-sensor on B-side defect. ==> short circuit or cable breakage
==> Check sensor and cable (B4.22), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Charge air pressure-sensor defect. ==> short circuit or cable breakage
==> Check sensor and cable (B10), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Lube oil pressure-sensor defect. ==> short circuit or cable breakage ==> Check sensor and cable (B5), if
necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Collant pressure-sensor defect. ==> short circuit or cable breakage
==> Check sensor and cable (B16), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Intercooler coolant pressure-sensor defect. ==> short circuit or cable breakage
==> Check sensor and cable (B43), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Crankcase pressure-sensor defect. ==> short circuit or cable breakage ==> Check sensor and cable (B50), if
necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Rail pressure-sensor defect. ==> High-pressure controller emergency operation ==> short circuit or cable
breakage
==> Check sensor and cable (B48), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Lube oil temperature-sensor defect. ==> short circuit or cable breakage
==> Check sensor and cable (B7), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Intake air temperature-sensor defect. ==> short circuit or cable breakage
==> Check sensor and cable (B3), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Sensor for coolant level defect. ==> short circuit or cable breakage
==> Check sensor and cable (F33), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Sensor for differential pressure of lube oil defect. ==> short circuit or cable breakage
==> Check sensor and cable (B5), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Sensor for leakage level of fuel defect. ==> short circuit or cable breakage
==> Check sensor and cable (F46), if necessary replace it.
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
6 von 33

ECU7 Software
No.

ZKP-No.

Name

223

1.8004.583

SD Level Coolant Intercooler

227

1.8004.620

SD P-Lube Oil before Filter

229

1.8004.562

AL Stop Camshaft Sensor


Defect

230

1.8004.498

SD Crankshaft Speed

231

1.8004.499

SD Camshaft Speed

232

1.3011.128

SD Charger 1 Speed

233

1.3011.129

SD Charger 2 Speed

240

1.8004.565

SD P-Fuel

241

1.8004.581

SD T-Umblasen

242

1.8004.622

SD T-Coolant (R)

244

1.8004.621

SD P-Lube Oil (R)

245

2.8006.589

SD ECU Power Supply


Voltage

266

2.8006.586

SD Speed Demand

269

2.8006.588

SD Loadp.Analog filt

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Sensor for coolant level of intercooler defect. ==> short circuit or cable breakage
==> Check sensor and cable (F57), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Pressure sensor for lube oil before filter defect. ==> short circuit or cable breakage
==> Check sensor and cable (B5.3), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Sensor of Camshaft defect and sensor of crankshaft defect before. ==> Engine stop
==> Check sensor and cable of B1, if necessary replace it. ==> After Engine restart curing of failure.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Sensor defect on crankshaft. ==> short circuit or cable breakage
==> Check sensor and cable (B13), if necessary replace it. After Engine restart follows curing of failure.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Sensor defect on camshaft. ==> short circuit or cable breakage ==> Check sensor and cable (B1), if necessary
replace it. After Engine restart follows curing of failure.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Speed-sensor of basic charger defect. ==> short circuit or cable breakage
==> Check sensor and cable (B44.1), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Speed-sensor of switching charger defect. ==> short circuit or cable breakage
==> Check sensor and cable (B44.2), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Fuel pressure-sensor defect. ==> short circuit or cable breakage
==> Check sensor and cable (B34), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Temperature-sensor of recirculated charge air defect. ==> short circuit or cable breakage
==> Check sensor and cable (B49), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Redundant coolant temperature-sensor defect. ==> short circuit or cable breakage
==> Check sensor and cable, if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Redundant pressure sensor for lube oil defect. ==> short circuit or cable breakage
==> Check sensor and cable, if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Internal ECU error. ==> electronic defect
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Analog speed demand defect. ==> short circuit or cable breakage
==> Check setpoint tacho-generator and cable, if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Filtered analog load pulse signal not available. ==> short circuit or cable breakage
==> Check cable, if necessary replace it.
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
7 von 33

ECU7 Software
No.

ZKP-No.

Name

270

2.8006.590

SD Frequency Input

301

1.8004.500

AL Timing Cylinder A1

302

1.8004.501

AL Timing Cylinder A2

303

1.8004.502

AL Timing Cylinder A3

304

1.8004.503

AL Timing Cylinder A4

305

1.8004.504

AL Timing Cylinder A5

306

1.8004.505

AL Timing Cylinder A6

307

1.8004.506

AL Timing Cylinder A7

308

1.8004.507

AL Timing Cylinder A8

309

1.8004.508

AL Timing Cylinder A9

310

1.8004.509

AL Timing Cylinder A10

311

1.8004.510

AL Timing Cylinder B1

312

1.8004.511

AL Timing Cylinder B2

313

1.8004.512

AL Timing Cylinder B3

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Frequency input defect ==> short circuit or cable breakage
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder A1: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder A2: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder A3: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder A4: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder A5: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder A6: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder A7: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder A8: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder A9: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder A10: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder B1: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder B2: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder B3: timing value too low / high.
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
8 von 33

ECU7 Software
No.

ZKP-No.

Name

314

1.8004.513

AL Timing Cylinder B4

315

1.8004.514

AL Timing Cylinder B5

316

1.8004.515

AL Timing Cylinder B6

317

1.8004.516

AL Timing Cylinder B7

318

1.8004.517

AL Timing Cylinder B8

319

1.8004.518

AL Timing Cylinder B9

320

1.8004.519

AL Timing Cylinder B10

321

1.8004.520

AL Wiring Cylinder A1

322

1.8004.521

AL Wiring Cylinder A2

323

1.8004.522

AL Wiring Cylinder A3

324

1.8004.523

AL Wiring Cylinder A4

325

1.8004.524

AL Wiring Cylinder A5

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder B4: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder B5: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder B6: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder B7: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder B8: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder B9: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder B10: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder A1. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder A2. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder A3. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder A4. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder A5. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
9 von 33

ECU7 Software
No.

ZKP-No.

Name

326

1.8004.525

AL Wiring Cylinder A6

327

1.8004.526

AL Wiring Cylinder A7

328

1.8004.527

AL Wiring Cylinder A8

329

1.8004.528

AL Wiring Cylinder A9

330

1.8004.529

AL Wiring Cylinder A10

331

1.8004.530

AL Wiring Cylinder B1

332

1.8004.531

AL Wiring Cylinder B2

333

1.8004.532

AL Wiring Cylinder B3

334

1.8004.533

AL Wiring Cylinder B4

335

1.8004.534

AL Wiring Cylinder B5

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder A6. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder A7. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder A8. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder A9. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder A10. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder B1. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder B2. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder B3. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder B4. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder B5. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
10 von 33

ECU7 Software
No.

ZKP-No.

Name

336

1.8004.535

AL Wiring Cylinder B6

337

1.8004.536

AL Wiring Cylinder B7

338

1.8004.537

AL Wiring Cylinder B8

339

1.8004.538

AL Wiring Cylinder B9

340

1.8004.539

AL Wiring Cylinder B10

341

1.8004.540

AL Open Load Cylinder A1

342

1.8004.541

AL Open Load Cylinder A2

343

1.8004.542

AL Open Load Cylinder A3

344

1.8004.543

AL Open Load Cylinder A4

345

1.8004.544

AL Open Load Cylinder A5

346

1.8004.545

AL Open Load Cylinder A6

347

1.8004.546

AL Open Load Cylinder A7

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder B6. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder B7. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder B8. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder B9. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder B10. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder A1 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder A2 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder A3 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder A4 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder A5 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder A6 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder A7 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
11 von 33

ECU7 Software
No.

ZKP-No.

Name

348

1.8004.547

AL Open Load Cylinder A8

349

1.8004.548

AL Open Load Cylinder A9

350

1.8004.549

AL Open Load Cylinder A10

351

1.8004.550

AL Open Load Cylinder B1

352

1.8004.551

AL Open Load Cylinder B2

353

1.8004.552

AL Open Load Cylinder B3

354

1.8004.553

AL Open Load Cylinder B4

355

1.8004.554

AL Open Load Cylinder B5

356

1.8004.555

AL Open Load Cylinder B6

357

1.8004.556

AL Open Load Cylinder B7

358

1.8004.557

AL Open Load Cylinder B8

359

1.8004.558

AL Open Load Cylinder B9

360

1.8004.559

AL Open Load Cylinder B10

361

1.8004.496

AL Power Stage Low

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder A8 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder A9 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder A10 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder B1 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder B2 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder B3 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder B4 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder B5 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder B6 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder B7 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder B8 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder B9 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder B10 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Internal error of electronic (electronic defect possible) ==> Start ITS ==> if electronic o.k. continue to pay
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
12 von 33

ECU7 Software
No.

ZKP-No.

Name

362

1.8004.497

AL Power Stage High

363

1.8004.560

AL Stop Power Stage

365

1.8004.561

AL Stop MV-Wiring Ground

371

1.8004.634

AL Wiring TO 1

372

1.8004.635

AL Wiring TO 2

373

1.8004.636

AL Wiring TO 3

374

1.8004.637

AL Wiring TO 4

381

2.8006.638

AL Wiring TOP 1

382

2.8006.639

AL Wiring TOP 2

383

2.8006.640

AL Wiring TOP 3

384

2.8006.641

AL Wiring TOP 4

390

1.1085.009

AL MCR exceeded

392

2.0129.931

HI T-Coolant (R)

393

2.0129.932

SS T-Coolant (R)

394

2.0112.921

LO P-Lube Oil (R)

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
attention to messages.
If bit "1.1020.021" (Power Stage Failure: Stop Engine) set ==> Engine stop.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Internal error of electronic (electronic defect possible) ==> Start ITS ==> if electronic o.k. continue to pay
attention to messages.
If bit "1.1020.021" (Power Stage Failure: Stop Engine) set ==> Engine stop.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Internal error of electronic (electronic defect possible) ==> Start ITS ==> if electronic o.k. continue to pay
attention to messages.
If bit "1.1020.021" (Power Stage Failure: Stop Engine) set ==> Engine stop.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Cable line error ==> If bit "1.1020.021" (Power Stage Failure: Stop Engine) set ==> Engine stop
==> possible causes:
1. short circuit of injector line-plus to ground.
2. short circuit of injector line-minus to ground.
==> Check cable, if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit or open load on transistor output 1 (TO 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit or open load on transistor output 2 (TO 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit or open load on transistor output 3 (TO 3).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit or open load on transistor output 4 (TO 4).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit or open load on transistor output plant 1 (TOP 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit or open load on transistor output plant 2 (TOP 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit or open load on transistor output plant 3 (TOP 3).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit or open load on transistor output plant 4 (TOP 4).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
DBR/MCR Function: MCR (Maximum Continuous Rating) is exceeded.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Redundant coolant temperature too high (limit 1) ==> Check circulation of coolant
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Redundant coolant temperature too high (limit 2) ==> Check circulation of coolant
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Redundant pressure of lube oil too low (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
13 von 33

ECU7 Software
No.

ZKP-No.

Name

395

2.0112.922

SS P-Lube Oil (R)

396

1.8004.626

TD T-Coolant

397

1.8004.625

TD P-Lube Oil

400

2.8006.625

AL Open Load Digital Input 1

401

2.8006.626

AL Open Load Digital Input 2

402

2.8006.627

AL Open Load Digital Input 3

403

2.8006.628

AL Open Load Digital Input 4

404

2.8006.629

AL Open Load Digital Input 5

405

2.8006.630

AL Open Load Digital Input 6

406

2.8006.631

AL Open Load Digital Input 7

407

2.8006.632

AL Open Load Digital Input 8

408

2.8006.633

AL Open Load Emerg. Stop


Input ESI

410

2.0141.921

LO U-PDU

411

2.0141.922

LOLO U-PDU

412

2.0141.931

HI U-PDU

413

2.0141.932

HIHI U-PDU

414

2.0156.931

HI Level Water Fuel Prefilter

415

2.0107.921

LO P-Coolant InterCooler

416

2.0107.922

SS P-Coolant InterCooler

417

1.8004.594

SD Level Water Fuel Prefilter

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
Redundant pressure of lube oil too low (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Maximum deviation of coolant temperature.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Maximum deviation of lube oil pressure.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open Load on digitil input 1. ==> cable breakage or no resistance above switch
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open Load on digitil input 2. ==> cable breakage or no resistance above switch
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open Load on digitil input 3. ==> cable breakage or no resistance above switch
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open Load on digitil input 4. ==> cable breakage or no resistance above switch
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open Load on digitil input 5. ==> cable breakage or no resistance above switch
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open Load on digitil input 6. ==> cable breakage or no resistance above switch
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open Load on digitil input 7. ==> cable breakage or no resistance above switch
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open Load on digitil input 8. ==> cable breakage or no resistance above switch
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open Load on input for emergency stop. ==> cable breakage or no resistance above switch
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Power driver voltage (injectors) too low (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Power driver voltage (injectors) too low (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Power driver voltage (injectors) too high (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Power driver voltage (injectors) too high (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Water level of fuel prefilter too high (limit 1) ==> empty fuel prefilter
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant pressure of InterCooler too low (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant pressure of InterCooler too low (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Water level-sensor of fuel prefilter defect. ==> short circuit or cable breakage
==> Check sensor and cable, if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
14 von 33

ECU7 Software
No.

ZKP-No.

420

2.0160.921

421

2.0160.922

428

2.0130.921

440

2.0110.921

442

2.0110.931

444

1.8004.578

445

1.8004.580

448

2.0103.931

449

2.0103.932

450

2.8006.592

454

2.7000.011

455

2.8006.650

456

2.8006.651

460

2.8006.652

461

2.8006.653

462

2.8006.654

464

1.8004.589

467

2.0130.922

468

1.8004.579

469

1.8004.590

Name

Description
Input of Aux 1 injured limit 1.
AL L1 Aux 1
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Input of Aux 1 injured limit 2.
AL L2 Aux1
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Temperature input of Aux 1 injured limit 1.
AL L1 T-Aux 1
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Pressure input of Aux 1 injured limit 1.
AL L1 P-Aux 1
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Pressure input of Aux 1 injured limit 2.
AL L2 P-Aux1
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Sensor defect of Injector Power driver unit. ==> Internal error of ECU7. Change ECU7.
SD U-PDU
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Ambient air pressure-sensor defect.
SD P-Ambient Air
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Pressure of charge air too high (limit 1).
HI P-Charge Air
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Pressure of charge air too high (limit 2).
SS P-Charge Air
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Input of Idle/End-Torque defect. ==> short circuit or cable breakage
SD Idle/End-Torque Input [%] ==> Check transmitter and cable, if necessary replace it. After Engine restart follows curing of failure.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Power Reduction is activated.
SS Power Reduction Active
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Input of Aux 1 (plant) injured limit 1.
AL L1 Aux1 Plant
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Input of Aux 1 (plant) injured limit 2.
AL L2 Aux1 Plant
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Exhaust gas temperature of EMU too high (limit 1).
HI T-Exhaust EMU
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Exhaust gas temperature of EMU too low (limit 1).
LO T-Exhaust EMU
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant temperature of EMU injured limit 1.
HI T-Coolant EMU
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Analog input for pressure Aux 1 defect. ==> short circuit or cable breakage
SD P-AUX 1
==> Check transmitter of pressure and cable, if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Temperature input of Aux 1 injured limit 2.
AL L2 T-Aux1
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Analog input for Temperature Aux 1 defect.
SD T-AUX 1
(Alarm Configuration Parameter, for details see PR 2.8008.100)
SD AUX 1
Analog input for Aux 1 defect. ==> short circuit or cable breakage

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
15 von 33

ECU7 Software
No.

ZKP-No.

Name

470

1.8004.587

SD T-ECU

471

1.8004.592

SD Coil Current

472

2.8006.593

AL Stop SD

473

1.8004.593

AL Wiring PWM_CM2

474

2.8006.655

AL Wiring FO

475

1.8010.009

AL CR Trigger Engine Stop

476

1.8010.007

AL Crash Rec. Init. Error

478

2.8006.001

AL Comb. Alarm Yel (Plant)

479

2.8006.002

AL Comb. Alarm Red (Plant)

480

2.0291.921

AL Ext. Engine Protection

500

1.4500.900

AL Wiring POM Starter 1

501

1.4500.901

AL Wiring POM Starter 2

502

1.4500.902

AL Open Load POM


Alternator

503

1.4500.903

AL Battery Not Charging

504

1.4500.904

AL CAN POM Node Lost

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
==> Check transmitter and cable, if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
ECU temperature-sensor defect. ==> short circuit or cable breakage
==> Check sensor and cable, if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coil Current sensor defect. ==> short circuit or cable breakage
==> Check sensor and cable, if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Engine stop, because critical channel has sensor defect.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load or short circuit on channel PWM_CM2.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load or short circuit on frequency output (FO) channel.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Released in case of an engine stop in order to trigger the crash recorder.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Initial error of crash recorder.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Combined Alarm YELLOW (Plant).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Combined Alarm RED (Plant).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
External Engine Protection function active.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
A wiring fault has been detected in the connection of starter 1 of CPM. This could be an open load, cable break
or short circuit.
==> Check connection between POM and starter.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
A wiring fault has been detected in the connection of starter 2 of CPM. This could be an open load, cable break
or short circuit.
==> Check connection between POM and starter.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
An open load on POM's alternator output has been detected.
==> Check connection between POM and alternator.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Battery is not being charged by alternator.
==> Check alternator and connection.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
POM is missing on CAN bus.
==> Check connection and POM.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
16 von 33

ECU7 Software
No.

ZKP-No.

Name

505

1.4500.905

AL New POM Found

506

1.4500.906

AL Low Starter Voltage

507

1.4500.907

AL POM Error

508

1.4500.908

AL Wrong POM-ID

509

1.4500.909

AL Check POM Fuse

510

2.7002.010

AL Override applied

515

2.1090.926

AL Starter Not Engaged

543

2.0555.005

AL Multiple FDH Slaves

544

2.0555.003

AL Configuration Changed

555

2.0555.001

AL Call MTU Field Service

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
A new POM has been found connected to the ECU.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Battery voltage is too low for starting.
==> Check starter battery and cabling.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
A general POM error has been detected.
==> Replace POM.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
POM sends a different identification number (ID) than expected.
==> Check POM harness.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Reserved.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Override applied.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Starter of CPM / POM could not be engaged. => New starting attempt.
If the number of automatic starting attempts from PR 1.1090.134 Number of Starting Attempts has been
executed, starting procedure is aborted. Check CPM, starter and cabling.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
There is more than one device which is configured as Backup for FDH-Functionality.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Gets active in case of changing system configuration e. g. by changing ECU- or SAM-Device.
Remains until undo procedure or data is transfered by a valid maintenance case.
Is cancelled automatically.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Gets active in case of completing a maintenance-case which manipulates Engine-Parameters.
Remains also after switching on-off ECU until a valid release code is entered via Display- and Button-Control of
SAM-Device.
Release Code is available via Internet by a special procedure.
(Alarm Configuration Parameter, for details see PR 2.8008.100)

Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
17 von 33

ECU7 Software

ZKP-No.

No.

Name

1.1085.009

390

AL MCR exceeded

1.3011.128

232

SD Charger 1 Speed

1.3011.129

233

SD Charger 2 Speed

1.4500.900

500

AL Wiring POM Starter 1

1.4500.901

501

AL Wiring POM Starter 2

1.4500.902

502

AL Open Load POM


Alternator

1.4500.903

503

AL Battery Not Charging

1.4500.904

504

AL CAN POM Node Lost

1.4500.905

505

AL New POM Found

1.4500.906

506

AL Low Starter Voltage

1.4500.907

507

AL POM Error

1.4500.908

508

AL Wrong POM-ID

1.4500.909

509

AL Check POM Fuse

1.8004.046

81

AL Rail Leakage

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
DBR/MCR Function: MCR (Maximum Continuous Rating) is exceeded.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Speed-sensor of basic charger defect. ==> short circuit or cable breakage
==> Check sensor and cable (B44.1), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Speed-sensor of switching charger defect. ==> short circuit or cable breakage
==> Check sensor and cable (B44.2), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
A wiring fault has been detected in the connection of starter 1 of CPM. This could be an open load, cable break
or short circuit.
==> Check connection between POM and starter.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
A wiring fault has been detected in the connection of starter 2 of CPM. This could be an open load, cable break
or short circuit.
==> Check connection between POM and starter.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
An open load on POM's alternator output has been detected.
==> Check connection between POM and alternator.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Battery is not being charged by alternator.
==> Check alternator and connection.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
POM is missing on CAN bus.
==> Check connection and POM.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
A new POM has been found connected to the ECU.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Battery voltage is too low for starting.
==> Check starter battery and cabling.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
A general POM error has been detected.
==> Replace POM.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
POM sends a different identification number (ID) than expected.
==> Check POM harness.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Reserved.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Rail pressure gradient too low for Start or too high for Stop
(==> High-pressure system leaks, air in the system)
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
18 von 33

ECU7 Software
ZKP-No.

No.

Name

1.8004.204

39

AL ETC2 CutIn Failure

1.8004.205

38

AL ETC Speed Deviation

1.8004.206

29

HI ETC Idle Speed too High

1.8004.496

361

AL Power Stage Low

1.8004.497

362

AL Power Stage High

1.8004.498

230

SD Crankshaft Speed

1.8004.499

231

SD Camshaft Speed

1.8004.500

301

AL Timing Cylinder A1

1.8004.501

302

AL Timing Cylinder A2

1.8004.502

303

AL Timing Cylinder A3

1.8004.503

304

AL Timing Cylinder A4

1.8004.504

305

AL Timing Cylinder A5

1.8004.505

306

AL Timing Cylinder A6

1.8004.506

307

AL Timing Cylinder A7

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Switching of charger ETC2 failed.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Speed deviation between basic turbo charger and one of the switcheable chargers.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Idle Speed of one of the switcheable chargers too high.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Internal error of electronic (electronic defect possible) ==> Start ITS ==> if electronic o.k. continue to pay
attention to messages.
If bit "1.1020.021" (Power Stage Failure: Stop Engine) set ==> Engine stop.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Internal error of electronic (electronic defect possible) ==> Start ITS ==> if electronic o.k. continue to pay
attention to messages.
If bit "1.1020.021" (Power Stage Failure: Stop Engine) set ==> Engine stop.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Sensor defect on crankshaft. ==> short circuit or cable breakage
==> Check sensor and cable (B13), if necessary replace it. After Engine restart follows curing of failure.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Sensor defect on camshaft. ==> short circuit or cable breakage ==> Check sensor and cable (B1), if necessary
replace it. After Engine restart follows curing of failure.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder A1: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder A2: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder A3: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder A4: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder A5: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder A6: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder A7: timing value too low / high.
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
19 von 33

ECU7 Software
ZKP-No.

No.

Name

1.8004.507

308

AL Timing Cylinder A8

1.8004.508

309

AL Timing Cylinder A9

1.8004.509

310

AL Timing Cylinder A10

1.8004.510

311

AL Timing Cylinder B1

1.8004.511

312

AL Timing Cylinder B2

1.8004.512

313

AL Timing Cylinder B3

1.8004.513

314

AL Timing Cylinder B4

1.8004.514

315

AL Timing Cylinder B5

1.8004.515

316

AL Timing Cylinder B6

1.8004.516

317

AL Timing Cylinder B7

1.8004.517

318

AL Timing Cylinder B8

1.8004.518

319

AL Timing Cylinder B9

1.8004.519

320

AL Timing Cylinder B10

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder A8: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder A9: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder A10: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder B1: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder B2: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder B3: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder B4: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder B5: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder B6: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder B7: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder B8: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder B9: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Error in timing of injector cylinder B10: timing value too low / high.
==> if very often replace solenoid
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
20 von 33

ECU7 Software
ZKP-No.

No.

Name

1.8004.520

321

AL Wiring Cylinder A1

1.8004.521

322

AL Wiring Cylinder A2

1.8004.522

323

AL Wiring Cylinder A3

1.8004.523

324

AL Wiring Cylinder A4

1.8004.524

325

AL Wiring Cylinder A5

1.8004.525

326

AL Wiring Cylinder A6

1.8004.526

327

AL Wiring Cylinder A7

1.8004.527

328

AL Wiring Cylinder A8

1.8004.528

329

AL Wiring Cylinder A9

1.8004.529

330

AL Wiring Cylinder A10

1.8004.530

331

AL Wiring Cylinder B1

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
Short circuit in injector cable of cylinder A1. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder A2. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder A3. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder A4. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder A5. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder A6. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder A7. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder A8. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder A9. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder A10. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder B1. ==> interrupted ignition
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
21 von 33

ECU7 Software
ZKP-No.

No.

Name

1.8004.531

332

AL Wiring Cylinder B2

1.8004.532

333

AL Wiring Cylinder B3

1.8004.533

334

AL Wiring Cylinder B4

1.8004.534

335

AL Wiring Cylinder B5

1.8004.535

336

AL Wiring Cylinder B6

1.8004.536

337

AL Wiring Cylinder B7

1.8004.537

338

AL Wiring Cylinder B8

1.8004.538

339

AL Wiring Cylinder B9

1.8004.539

340

AL Wiring Cylinder B10

1.8004.540

341

AL Open Load Cylinder A1

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder B2. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder B3. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder B4. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder B5. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder B6. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder B7. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder B8. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder B9. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit in injector cable of cylinder B10. ==> interrupted ignition
==> Remove short circuit of solenoid (plus to ground) (e.g. replace injector)
==> after engine restart curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder A1 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
22 von 33

ECU7 Software
ZKP-No.

No.

Name

1.8004.541

342

AL Open Load Cylinder A2

1.8004.542

343

AL Open Load Cylinder A3

1.8004.543

344

AL Open Load Cylinder A4

1.8004.544

345

AL Open Load Cylinder A5

1.8004.545

346

AL Open Load Cylinder A6

1.8004.546

347

AL Open Load Cylinder A7

1.8004.547

348

AL Open Load Cylinder A8

1.8004.548

349

AL Open Load Cylinder A9

1.8004.549

350

AL Open Load Cylinder A10

1.8004.550

351

AL Open Load Cylinder B1

1.8004.551

352

AL Open Load Cylinder B2

1.8004.552

353

AL Open Load Cylinder B3

1.8004.553

354

AL Open Load Cylinder B4

1.8004.554

355

AL Open Load Cylinder B5

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder A2 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder A3 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder A4 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder A5 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder A6 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder A7 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder A8 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder A9 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder A10 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder B1 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder B2 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder B3 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder B4 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder B5 ==> Interrupted ignition ==> Check cable and solenoid if open load
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
23 von 33

ECU7 Software
ZKP-No.

No.

Name

1.8004.555

356

AL Open Load Cylinder B6

1.8004.556

357

AL Open Load Cylinder B7

1.8004.557

358

AL Open Load Cylinder B8

1.8004.558

359

AL Open Load Cylinder B9

1.8004.559

360

AL Open Load Cylinder B10

1.8004.560

363

AL Stop Power Stage

1.8004.561

365

AL Stop MV-Wiring Ground

1.8004.562

229

AL Stop Camshaft Sensor


Defect

1.8004.563

211

SD P-Lube Oil

1.8004.564

212

SD P-Coolant

1.8004.565

240

SD P-Fuel

1.8004.566

208

SD P-Charge Air

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder B6 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder B7 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder B8 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder B9 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load in injector cable of cylinder B10 ==> Interrupted ignition ==> Check cable and solenoid if open load
(e.g. replace injector) ==> after cycle curing of failure
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Internal error of electronic (electronic defect possible) ==> Start ITS ==> if electronic o.k. continue to pay
attention to messages.
If bit "1.1020.021" (Power Stage Failure: Stop Engine) set ==> Engine stop.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Cable line error ==> If bit "1.1020.021" (Power Stage Failure: Stop Engine) set ==> Engine stop
==> possible causes:
1. short circuit of injector line-plus to ground.
2. short circuit of injector line-minus to ground.
==> Check cable, if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Sensor of Camshaft defect and sensor of crankshaft defect before. ==> Engine stop
==> Check sensor and cable of B1, if necessary replace it. ==> After Engine restart curing of failure.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Lube oil pressure-sensor defect. ==> short circuit or cable breakage ==> Check sensor and cable (B5), if
necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Collant pressure-sensor defect. ==> short circuit or cable breakage
==> Check sensor and cable (B16), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Fuel pressure-sensor defect. ==> short circuit or cable breakage
==> Check sensor and cable (B34), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Charge air pressure-sensor defect. ==> short circuit or cable breakage
==> Check sensor and cable (B10), if necessary replace it.
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
24 von 33

ECU7 Software
ZKP-No.

No.

Name

1.8004.567

215

SD P-HD

1.8004.568

214

SD P-CrankCase

1.8004.569

213

SD P-Coolant Intercooler

1.8004.570

201

SD T-Coolant

1.8004.571

203

SD T-Charge Air

1.8004.572

202

SD T-Fuel

1.8004.573

219

SD T-Intake Air

1.8004.574

205

SD T-Coolant Intercooler

1.8004.575

216

SD T-Lube Oil

1.8004.576

206

SD T-Exhaust A

1.8004.577

207

SD T-Exhaust B

1.8004.578

444

SD U-PDU

1.8004.579

468

SD T-AUX 1

1.8004.580

445

SD P-Ambient Air

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Rail pressure-sensor defect. ==> High-pressure controller emergency operation ==> short circuit or cable
breakage
==> Check sensor and cable (B48), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Crankcase pressure-sensor defect. ==> short circuit or cable breakage ==> Check sensor and cable (B50), if
necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Intercooler coolant pressure-sensor defect. ==> short circuit or cable breakage
==> Check sensor and cable (B43), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant temperature-sensor defect. ==> short circuit or cable breakage
==> Check sensor and cable (B6), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Charge air temperature-sensor defect. ==> short circuit or cable breakage
==> Check sensor and cable (B9), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Fuel temperature-sensor defect. ==> short circuit or cable breakage
==> Check sensor and cable (B33), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Intake air temperature-sensor defect. ==> short circuit or cable breakage
==> Check sensor and cable (B3), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Intercooler coolant temperature-sensor defect. ==> short circuit or cable breakage
==> Check sensor and cable (B26), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Lube oil temperature-sensor defect. ==> short circuit or cable breakage
==> Check sensor and cable (B7), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Exhaust gas temperature-sensor on A-side defect. ==> short circuit or cable breakage
==> Check sensor and cable (B4.21), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Exhaust gas temperature-sensor on B-side defect. ==> short circuit or cable breakage
==> Check sensor and cable (B4.22), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Sensor defect of Injector Power driver unit. ==> Internal error of ECU7. Change ECU7.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Analog input for Temperature Aux 1 defect.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Ambient air pressure-sensor defect.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
25 von 33

ECU7 Software
ZKP-No.

No.

Name

1.8004.581

241

SD T-Umblasen

1.8004.582

222

SD Level Leakage Fuel

1.8004.583

223

SD Level Coolant Intercooler

1.8004.584

220

SD Level Coolant Water

1.8004.585

221

SD P-Diff Lube Oil

1.8004.587

470

SD T-ECU

1.8004.589

464

SD P-AUX 1

1.8004.590

469

SD AUX 1

1.8004.592

471

SD Coil Current

1.8004.593

473

AL Wiring PWM_CM2

1.8004.594

417

SD Level Water Fuel Prefilter

1.8004.620

227

SD P-Lube Oil before Filter

1.8004.621

244

SD P-Lube Oil (R)

1.8004.622

242

SD T-Coolant (R)

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
Temperature-sensor of recirculated charge air defect. ==> short circuit or cable breakage
==> Check sensor and cable (B49), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Sensor for leakage level of fuel defect. ==> short circuit or cable breakage
==> Check sensor and cable (F46), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Sensor for coolant level of intercooler defect. ==> short circuit or cable breakage
==> Check sensor and cable (F57), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Sensor for coolant level defect. ==> short circuit or cable breakage
==> Check sensor and cable (F33), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Sensor for differential pressure of lube oil defect. ==> short circuit or cable breakage
==> Check sensor and cable (B5), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
ECU temperature-sensor defect. ==> short circuit or cable breakage
==> Check sensor and cable, if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Analog input for pressure Aux 1 defect. ==> short circuit or cable breakage
==> Check transmitter of pressure and cable, if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Analog input for Aux 1 defect. ==> short circuit or cable breakage
==> Check transmitter and cable, if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coil Current sensor defect. ==> short circuit or cable breakage
==> Check sensor and cable, if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load or short circuit on channel PWM_CM2.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Water level-sensor of fuel prefilter defect. ==> short circuit or cable breakage
==> Check sensor and cable, if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Pressure sensor for lube oil before filter defect. ==> short circuit or cable breakage
==> Check sensor and cable (B5.3), if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Redundant pressure sensor for lube oil defect. ==> short circuit or cable breakage
==> Check sensor and cable, if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Redundant coolant temperature-sensor defect. ==> short circuit or cable breakage
==> Check sensor and cable, if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
26 von 33

ECU7 Software
ZKP-No.

No.

1.8004.623

104

1.8004.624

102

1.8004.625

397

1.8004.626

396

1.8004.634

371

1.8004.635

372

1.8004.636

373

1.8004.637

374

1.8010.007

476

1.8010.009

475

2.0100.921

15

2.0100.922

16

2.0101.921

57

2.0101.922

58

2.0102.921

65

2.0102.922

66

2.0103.931

448

2.0103.932

449

2.0104.921

83

2.0104.931

82

Name

Description
Engine Hours Counter defect.
AL Eng Hours Counter Defect
(Alarm Configuration Parameter, for details see PR 2.8008.100)
AL Fuel Cons. Counter
Fuel consumption counter defect.
Defect
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Maximum deviation of lube oil pressure.
TD P-Lube Oil
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Maximum deviation of coolant temperature.
TD T-Coolant
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit or open load on transistor output 1 (TO 1).
AL Wiring TO 1
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit or open load on transistor output 2 (TO 2).
AL Wiring TO 2
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit or open load on transistor output 3 (TO 3).
AL Wiring TO 3
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit or open load on transistor output 4 (TO 4).
AL Wiring TO 4
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Initial error of crash recorder.
AL Crash Rec. Init. Error
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Released in case of an engine stop in order to trigger the crash recorder.
AL CR Trigger Engine Stop
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Pressure of lube oil too low (limit 1).
LO P-Lube Oil
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Pressure of lube oil too low (limit 2).
SS P-Lube Oil
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant pressure too low (limit 1) ==> check cooling cycle.
LO P-Coolant
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant pressure too low (limit 2) ==> Engine stop or limitation of the injection quantity ==> check cooling cycle
SS P-Coolant
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Fuel supply pressure too low (limit 1) ==> Check filter, fuel on low-pressure side
LO P-Fuel
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Fuel supply pressure too low (limit 2) ==> Check filter (low-pressure side)
SS P-Fuel
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Pressure of charge air too high (limit 1).
HI P-Charge Air
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Pressure of charge air too high (limit 2).
SS P-Charge Air
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Rail pressure < setpoint value => DBR reduction
LO P-Fuel (Common Rail)
(==> interphase transformer defective or leakage in high-pressure system)
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Rail pressure > setpoint value => DBR reduction, shift of start of injection delayed
HI P-Fuel (Common Rail)
(==> interphase transformer sticks or connections of the interphase transformer)

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
27 von 33

ECU7 Software
ZKP-No.

No.

Name

2.0106.931

63

HI P-Crank Case

2.0106.932

64

SS P-Crank Case

2.0107.921

415

LO P-Coolant InterCooler

2.0107.922

416

SS P-Coolant InterCooler

2.0110.921

440

AL L1 P-Aux 1

2.0110.931

442

AL L2 P-Aux1

2.0112.921

394

LO P-Lube Oil (R)

2.0112.922

395

SS P-Lube Oil (R)

2.0120.931

67

HI T-Coolant

2.0120.932

68

SS T-Coolant

2.0120.933

59

SS T-Coolant L3

2.0120.934

60

SS T-Coolant L4

2.0121.931

HI T-Charge Air

2.0121.932

SS T-Charge Air

2.0122.931

HI T-Fuel

2.0122.932

SS T-Fuel

2.0124.931

HI T-Coolant Intercooler

2.0124.932

10

SS T-Coolant Intercooler

2.0125.931

51

HI T-Lube Oil

2.0125.932

52

SS T-Lube Oil

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Crankcase pressure too high (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Crankcase pressure too high (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant pressure of InterCooler too low (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant pressure of InterCooler too low (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Pressure input of Aux 1 injured limit 1.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Pressure input of Aux 1 injured limit 2.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Redundant pressure of lube oil too low (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Redundant pressure of lube oil too low (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant temperature too high (limit 1) ==> Check circulation of coolant
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant temperature too high (limit 2) ==> Check circulation of coolant
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant temperature too high/ too low (limit 3).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant temperature too high/ too low (limit 4).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Charge air temperature too high (limit 1) ==> Check InterCooler
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Charge air temperature too high (limit 2) ==> Check InterCooler
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Fuel temperature too high (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Fuel temperature too high (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant temperature of InterCooler too high (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant temperature of InterCooler too high (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Lube oil temperature too high (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Lube oil temperature to high (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
28 von 33

ECU7 Software
ZKP-No.

No.

Name

2.0126.931

19

HI T-Exhaust A

2.0126.932

20

SS T-Exhaust A

2.0127.931

21

HI T-Exhaust B

2.0127.932

22

SS T-Exhaust B

2.0128.931

85

HI T-Umblasen

2.0128.932

86

SS T-Umblasen

2.0129.931

392

HI T-Coolant (R)

2.0129.932

393

SS T-Coolant (R)

2.0130.921

428

AL L1 T-Aux 1

2.0130.922

467

AL L2 T-Aux1

2.0132.921

122

HI T-ECU

2.0140.921

118

2.0140.922

119

2.0140.931

120

2.0140.932

121

2.0141.921

410

LO U-PDU

2.0141.922

411

LOLO U-PDU

2.0141.931

412

HI U-PDU

2.0141.932

413

HIHI U-PDU

2.0151.931

27

HI Level Leakage Fuel

2.0152.921

23

LO Coolant Level

LO ECU Power Supply


Voltage
LOLO ECU Power Supply
Voltage
HI ECU Power Supply
Voltage
HIHI ECU Power Supply
Voltage

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
Exhaust gas temperature (A-side) too high (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Exhaust gas temperature (A-side) too high (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Exhaust gas temperature (B-side) too high (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Exhaust gas temperature (B-side) too high (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Umblasen' temperature too high (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Umblasen' temperature too high (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Redundant coolant temperature too high (limit 1) ==> Check circulation of coolant
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Redundant coolant temperature too high (limit 2) ==> Check circulation of coolant
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Temperature input of Aux 1 injured limit 1.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Temperature input of Aux 1 injured limit 2.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Temperature of electronic too high (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Power supply voltage too low (limit 1) ==> Check battery / generator
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Power supply voltage too low (limit 2) ==> Check battery / generator
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Power supply voltage too high (limit 1) ==> Check battery / generator
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Power supply voltage too high (limit 2) ==> Check battery / generator
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Power driver voltage (injectors) too low (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Power driver voltage (injectors) too low (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Power driver voltage (injectors) too high (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Power driver voltage (injectors) too high (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Level of leakage fuel too high (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant level too low (limit 1) ==> Check coolant level in compensation container
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
29 von 33

ECU7 Software
ZKP-No.

No.

Name

2.0153.921

44

LO Coolant Level Intercooler

2.0154.931

25

HI P-Diff-Lube Oil

2.0154.932

26

SS P-Diff-Lube Oil

2.0156.931

414

HI Level Water Fuel Prefilter

2.0160.921

420

AL L1 Aux 1

2.0160.922

421

AL L2 Aux1

2.0291.921

480

AL Ext. Engine Protection

2.0500.680

180

AL CAN1 Node Lost

2.0500.681

181

AL CAN2 Node Lost

2.0500.682

182

AL CAN Wrong Parameters

2.0500.683

183

AL CAN No PU-Data

2.0500.684

184

AL CAN PU-Data Flash Error

2.0500.686

186

AL CAN1 Bus Off

2.0500.687

187

AL CAN1 Error Passive

2.0500.688

188

AL CAN2 Bus Off

2.0500.689

189

AL CAN2 Error Passive

2.0500.690

190

AL EMU Parameter Not

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant level of intercooler too low (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Differential pressure of oilfilter too high (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Differential pressure of oilfilter too high (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Water level of fuel prefilter too high (limit 1) ==> empty fuel prefilter
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Input of Aux 1 injured limit 1.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Input of Aux 1 injured limit 2.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
External Engine Protection function active.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Connection to a node on CAN bus 1 lost. ==> Check devices connected on CAN
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Connection to a node on CAN bus 2 lost. ==> Check devices connected on CAN
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Incorrect CAN parameter values have been entered.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
A CAN mode is selected which the communication is initialized aided of the PU data module. However,
required PU data module is not present or is not valid.
==> Check the devices connected by CAN
(Alarm Configuration Parameter, for details see PR 2.8008.100)
During attempt to copy a received PU data module to Flash module, a program error occurred. ==> Electronic
service
(Alarm Configuration Parameter, for details see PR 2.8008.100)
CAN Controller 1 is in "Bus Off" state => Automatic switchover to CAN2
==>causes e.g. short circuit, massive interference or baud rate incompatibility
(Alarm Configuration Parameter, for details see PR 2.8008.100)
CAN Controller 1 has signaled a warning. ==> causes e.g. lack of associated nodes, slight interference or
short-term bus overload.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
CAN-Controller 2 is in "Bus Off" state => Automatic switchover to CAN 1 ==>causes e.g. short circuit, massive
interference or baud rate incompatibility.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
CAN Controller 2 has signaled a warning. ==> causes e.g. lack of associated nodes, slight interference or
short-term bus overload.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
EMU parameters are not supported. ==> Incompatibility
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
30 von 33

ECU7 Software
ZKP-No.

No.

Name
Supported

2.0555.001

555

AL Call MTU Field Service

2.0555.003

544

AL Configuration Changed

2.0555.005

543

AL Multiple FDH Slaves

2.1090.920

95

AL Prelubrication Fault

2.1090.921

94

LO T-Preheat

2.1090.922

93

SS T-Preheat

2.1090.923

92

2.1090.924

91

2.1090.925

90

SS Idle Speed Not Reached

2.1090.926

515

AL Starter Not Engaged

2.2500.030

89

SS Engine Speed too Low

2.2510.932

30

SS Engine Overspeed

2.3011.931

31

HI ETC1 Overspeed

2.3012.932

32

SS ETC1 Overspeed

2.3013.912

37

SS ETC2 Overspeed

2.3013.931

36

HI ETC2 Overspeed

SS Starter Speed Not


Reached
SS Release Speed Not
Reached

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Gets active in case of completing a maintenance-case which manipulates Engine-Parameters.
Remains also after switching on-off ECU until a valid release code is entered via Display- and Button-Control of
SAM-Device.
Release Code is available via Internet by a special procedure.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Gets active in case of changing system configuration e. g. by changing ECU- or SAM-Device.
Remains until undo procedure or data is transfered by a valid maintenance case.
Is cancelled automatically.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
There is more than one device which is configured as Backup for FDH-Functionality.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Prelubrication fault.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Preheat temperature too low (limit 1) ==> Coolant temperature for engine start too low
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Preheat temperature too low (limit 2) ==> Coolant temperature for engine start too low ==> Bolting engine start
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Starter speed not reached ==> Start abort ==> Starter does not turn or turns too slowly
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Acceleration speed not reached ==> Start abort ==> observe other messages
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Idle speed not reached ==> Start abort ==> pay attention to other messages
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Starter of CPM / POM could not be engaged. => New starting attempt.
If the number of automatic starting attempts from PR 1.1090.134 Number of Starting Attempts has been
executed, starting procedure is aborted. Check CPM, starter and cabling.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Engine is being stalled. The engine speed of the normally operating engine dropped below the limit from
parameter 2.2500.027 Limit Engine Speed Low without any stop request. For safety reason the engine is
stopped when this event occurs.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Engine Overspeed (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Speed of basic charger too high (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Speed of basic charger too high (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Speed of 1st switcheable charger too high (limit 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Speed of 1st switcheable charger too high (limit 1).
Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
31 von 33

ECU7 Software
ZKP-No.

No.

2.4000.004

176

2.4000.006

177

2.7000.011

454

2.7002.010

510

2.8006.001

478

2.8006.002

479

2.8006.586

266

2.8006.588

269

2.8006.589

245

2.8006.590

270

2.8006.592

450

2.8006.593

472

2.8006.625

400

2.8006.626

401

2.8006.627

402

2.8006.628

403

2.8006.629

404

2.8006.630

405

Name

Description
(Alarm Configuration Parameter, for details see PR 2.8008.100)
No (fitting) LifeData-Backup-System is available within a delaytime after ECU-Reset . ==> Backup-system has
AL LifeData not available
no LifeData-function or CAN bus interrupted to Backup-system.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
If the ADEC has to restore the LifeData from the backup-system and at least one checksum is wrong after the
AL LifeData restore
upload or the upload is incomplete, then this failure is set.
incomplete
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Power Reduction is activated.
SS Power Reduction Active
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Override applied.
AL Override applied
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Combined Alarm YELLOW (Plant).
AL Comb. Alarm Yel (Plant)
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Combined Alarm RED (Plant).
AL Comb. Alarm Red (Plant)
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Analog speed demand defect. ==> short circuit or cable breakage
SD Speed Demand
==> Check setpoint tacho-generator and cable, if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Filtered analog load pulse signal not available. ==> short circuit or cable breakage
SD Loadp.Analog filt
==> Check cable, if necessary replace it.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
SD ECU Power Supply
Internal ECU error. ==> electronic defect
Voltage
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Frequency input defect ==> short circuit or cable breakage
SD Frequency Input
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Input of Idle/End-Torque defect. ==> short circuit or cable breakage
SD Idle/End-Torque Input [%] ==> Check transmitter and cable, if necessary replace it. After Engine restart follows curing of failure.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Engine stop, because critical channel has sensor defect.
AL Stop SD
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open Load on digitil input 1. ==> cable breakage or no resistance above switch
AL Open Load Digital Input 1
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open Load on digitil input 2. ==> cable breakage or no resistance above switch
AL Open Load Digital Input 2
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open Load on digitil input 3. ==> cable breakage or no resistance above switch
AL Open Load Digital Input 3
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open Load on digitil input 4. ==> cable breakage or no resistance above switch
AL Open Load Digital Input 4
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open Load on digitil input 5. ==> cable breakage or no resistance above switch
AL Open Load Digital Input 5
(Alarm Configuration Parameter, for details see PR 2.8008.100)
AL Open Load Digital Input 6 Open Load on digitil input 6. ==> cable breakage or no resistance above switch

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
32 von 33

ECU7 Software
ZKP-No.

No.

Name

2.8006.631

406

AL Open Load Digital Input 7

2.8006.632

407

AL Open Load Digital Input 8

2.8006.633

408

AL Open Load Emerg. Stop


Input ESI

2.8006.638

381

AL Wiring TOP 1

2.8006.639

382

AL Wiring TOP 2

2.8006.640

383

AL Wiring TOP 3

2.8006.641

384

AL Wiring TOP 4

2.8006.650

455

AL L1 Aux1 Plant

2.8006.651

456

AL L2 Aux1 Plant

2.8006.652

460

HI T-Exhaust EMU

2.8006.653

461

LO T-Exhaust EMU

2.8006.654

462

HI T-Coolant EMU

2.8006.655

474

AL Wiring FO

Dokument
ADEC Error List SFW 2_1_1_1_11_0 SFW 2_2_33_1_1_0.doc

Description
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open Load on digitil input 7. ==> cable breakage or no resistance above switch
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open Load on digitil input 8. ==> cable breakage or no resistance above switch
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open Load on input for emergency stop. ==> cable breakage or no resistance above switch
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit or open load on transistor output plant 1 (TOP 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit or open load on transistor output plant 2 (TOP 2).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit or open load on transistor output plant 3 (TOP 3).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Short circuit or open load on transistor output plant 4 (TOP 4).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Input of Aux 1 (plant) injured limit 1.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Input of Aux 1 (plant) injured limit 2.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Exhaust gas temperature of EMU too high (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Exhaust gas temperature of EMU too low (limit 1).
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Coolant temperature of EMU injured limit 1.
(Alarm Configuration Parameter, for details see PR 2.8008.100)
Open load or short circuit on frequency output (FO) channel.
(Alarm Configuration Parameter, for details see PR 2.8008.100)

Version
1.0

Datum
00.00.2006

Autor
TEE

Seite
33 von 33

You might also like