Insulator
Insulator
Insulator
Catalogue TD-IPS
ISO9001
SAI GLOBAL
FILE No. 000117
PERFORMANCE BENEFITS
The performance benefits of KLI InterPhase Spacer Insulators are listed below.
Improves Reliability (minimizes interruptions and outages due to conductor contact, flashovers or plant
damage in all types of environments)
Safety (light weight for handling and installation)
Service Life (consistent performance over its service life)
Life Cycle Cost (savings over porcelain insulators)
APPLICATION
One or two InterPhase Spacers are installed in each span. One Spacer is installed if there are two vertically
positioned conductors and it is installed at one-third of the span. Two Spacers are installed if there are three
vertically positioned conductors. The first Spacer is installed between the mid and lower conductors one-third of
the span from one end. The second Spacer is installed between the mid and upper conductor one-quarter of the
span from the other end. Contact your KLI Representative for application / placement instructions.
CORE ROD
The core rod of the insulator is made of a high quality, epoxy resin, E-Glass fiberglass rod that has been specially
formulated for electrical and mechanical applications.
HOUSING
The housing (includes sheath and sheds) of the insulator is one piece, high temperature vulcanized, injection
molded silicone rubber that is chemically bonded to the core rod. This ensures that the interface between the
rubber and rod is impenetrable against moisture ingress. KLI uses its own proprietary silicone rubber formula in
the manufacture of its insulators. The formulation has silicone rubber as the base polymer material with additives
to enhance its performance in wet and contaminated environments.
ITEM
1
2
3
4
5
6
7
SPECIFICATION
OPERATING VOLTAGE (PHASE PHASE)
MOUNTING ARRANGEMENT: 1) HORIZONTAL 2) VERTICAL
LENGTH L (CONDUCTOR CONDUCTOR)
CONDUCTOR DIAMETER (INCLUDING ARMOUR ROD IF APPLICABLE)
CONDUCTOR CLAMP: 1) SUSPENSION 2) K-CLAMP 3) RISER
POLLUTION LEVEL (IEC 60815)
EYE NUT OPTION FOR LIVE LINE APPLICATION (SEE DETAIL A)
DATA
kV
mm
mm
YES
NO
NOTE:
1. OTHER DESIGNS ARE AVAILABLE, PLEASE CONTACT KLI FOR DETAILS.
ITEM
1
2
3
4
5
6
7
SPECIFICATION
OPERATING VOLTAGE (PHASE PHASE)
MOUNTING ARRANGEMENT: 1) HORIZONTAL 2) VERTICAL
LENGTH L (CONDUCTOR CONDUCTOR)
CONDUCTOR DIAMETER (INCLUDING ARMOUR ROD IF APPLICABLE)
CONDUCTOR CLAMP: 1) SUSPENSION 2) K-CLAMP 3) RISER
POLLUTION LEVEL (IEC 60815)
EYE BOLT OPTION FOR LIVE LINE APPLICATION (SEE DETAIL A)
DATA
kV
mm
mm
YES
NO
NOTE:
1. OTHER DESIGNS ARE AVAILABLE, PLEASE CONTACT KLI FOR DETAILS.
ITEM
1
2
3
4
5
6
SPECIFICATION
DATA
kV
mm
mm
NOTE:
1. OTHER DESIGNS ARE AVAILABLE, PLEASE CONTACT KLI FOR DETAILS.
October 2013