HighPROTEC

Protection Technology
made simple

MRDT4

Transformer Differential Protection Relay

Disturbance recorder
120 s non volatile,
32 samples per cycles
event recorder
300 events
Last 50 non volatile
Additional highlights
Inrush
Thermal replica
Four stages external protection
Plausibility checks
Adaptive parameter sets
Status display
Masking of unused functions
Commissioning support (forcing
and disarming relays)

Application

comprehensive measured values


and statistics
THD (total harmonic distortion)
Current phasors and angles
RMS and fundamental

The MRDT4 is a protection relay which


uses the latest Dual-Core-Processor
Technology to provide precise and reliable protective functions and is very
easy to operate. Its various protective
functions are specifically tailored to
the protection of two winding transformers and offers in addition to that
various overcurrent backup protection functions.

C.T. missmatch correction


Autom. magnitude and phase
compensation
Zero sequence removal
High set element (unrestraint)

All inclusive:
All protection features without
extra charge
Parameter setting and
evaluation software
Disturbance record analysis
software

Four stages (Backup Protection)


Overcurrent/short-circuit
protection (non-directional)
Earth fault protection
(non-directional)
Tripping characteristics:
DEFT
ANSI: NINV, VINV, EINV
IEC: NINV, VINV, LINV, EINV
Thermal Flat, IT, I2T, I4T

two stages transformer differential protection


Stabilized tripping characteristic,
transients and C.T. saturation
(temporarily restraint)
Various selectable transformer
groups

two stages ground differential


protection
Three point slope characteristic
High set element (non-restraint)

two stages unbalanced load


protection
Supervision by definite time or
tripping characteristic

iriG-B00X
Time accuracy of 1ms
All time synchronization
formats (IRIG-B000 ... B007)
36 UTC Time Zones
Transmission of up to 18 synchronized control commands
temperature protection
Buchholz (sudden pressure), ext.
oil temperature, and aux. temperature protection via digital
input
Parameter setting support by
software
Copy parameter sets
Compare parameter sets
Setting files are up and down
convertible (across versions)
supervision
Current transformer supervision
Circuit breaker failure protection
Trip circuit supervision
Cold load pickup
Switch onto fault

Functional Overview
Protective Functions

Elements

ANSI

Transformer differential protection (2 windings), Id>, Id>>,


Curve with zero point and two settable slopes and short circuit differential threshold Id>>, voltage ratio
between primary and secondary setable, Inrush stabilisation / detection 2 harmonics

87T

Restricted earth fault IdE>, IdE>>, characteristics similar to 87T

87G (64REF)

I, time overcurrent and short circuit protection (non-directional).


Tremendous reset options (instantaneous, definite time, reset characteristics according to IEC and ANSI).

50P, 51P

I2>, unbalanced load protection with evaluation of the negative phase sequence currents

46

IB, overload protection with thermal replica for transformers IEC60255-8, alarm and trip threshold

49T

IH2/In, inrush detection with evaluation of the 2nd harmonic

Inrush

IE, earth overcurrent and short circuit protection (non-directional).


Tremendous reset options (instantaneous, definite time, reset characteristics according to IEC and ANSI).

50N, 51N

ExP, External alarm and trip functions

Supervision functions

Elements

ANSI

CBF, circuit breaker failure protection for both circuit breakers

50BF

TCS, trip circuit supervision

74TC

CTS, current transformer supervision

60L

CLPU, cold load pickup

SOTF, switch onto fault

Non volatile event recorder up to 120 s with 32 samples per cycles

Connections

Functional overview in ANSI form


Typical Configuration
Winding Side 1

Winding Side 2

W1
74TC

W1
50N

W2
50N

W2
74TC

W1
86

W1
51N

W2
51N

W2
86

W1
Inrush

W1
87N

W2
87N

W2
Inrush

W1
50
W1
51
W1
46

Metering
Current Max/Min/Avg
THD Current
Current Phasors
Sequence Currents
Diff Currents
Harmonic Currents

W2
50
W2
51
W2
46
W2
50BF

W1
50BF
Fault recorder

URTD interface

MRDT4

49

Disturbance recorder

RTD
Prot
IRIG

W1 or W2
CLPU
W1 or W2
SOTF
87T
64REF

Comm Interface(s)
+Protocols

Breaker Wear (2 elements)

Event recorder

Order form MrDt4


non-directional transformer Differential Protection MrDt4
Digital
Inputs

Binary output relay

Housing

Large
display

8
16

7
13

B2
B2

Hardware variant 2
Standard

A
D
0

Housing and mounting


Door mounting
Door mounting 19 (flush mounting)
Communication protocol
Without protocol
RS485/terminals, Modbus RTU, IEC60870-5-103
Modbus TCP, IEC61850 prepared (Hardware interface)/Ethernet 100 MB/RJ45
connector
Profibus-DP, optic fibre
Profibus-DP, RS485/D-SUB
Optic fiber, Modbus RTU, IEC60870-5-103
RS485/D-SUB, Modbus RTU, IEC60870-5-103
Presetting of available menu languages
Standard English/German

A
B
A
B
c
D
e
F
G

The devices can be updated via device front interface (RS232) and PC locally

current inputs
Digital inputs
Power supply
terminals
Mounting
type of enclosure
Dimensions of housing
Weight (max. components)

4 (1 A and 5 A) with automatic short circuiters


Switching thresholds adjustable via software
Wide range power supply
All terminals plug type
Door mounting
IP54
212.7 mm x 173 mm x 209 mm (W x H x D)
approx. 4 kg

Woodward SEG GmbH & Co. KG


Krefelder Weg 47
D - 47906 Kempen

Service
Telefon: +49 (0) 21 52 1 45 - 6 14/3 34
Fax.: +49 (0) 21 52 1 45 - 4 55
e-mail: [email protected]

Visit us at www.eps.woodward.com

Enabling Electrical Power Systems Integration

DOK_FLY_MRDT4_12.09_EN

Sales Team
Phone: +49 (0) 21 52 1 45 - 1
Fax.: +49 (0) 21 52 1 45 - 3 54
e-mail: [email protected]

You might also like