STF Kemim Valve

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

IPR -B

pressure regulator
spring loaded

97/23/CE
Notified Body number 1370

IPR regulators are a new line of pressure


regulators direct operating type designed to
guarantee a high regulation accuracy and an
utmost easiness in use.
These devices are usually used in distribution and
industrial systems and are designed to be
installed in regulation units of canalized nets of
natural, manufactured and lpg gas or other non
corrosive gases, filtered at first.

STF KEMIM S.r.l.


strada provinciale 33 Km. 0,6
20080 Vernate (MI)
Tel. (39).02.9052621
Fax.(39).02.9052631
E-mail : [email protected]
www.samgasgroup.it

Rev. 02 del 01/01/2006

IPR -B
The mod. IPR pressure regulators are fail to
open type, which means that in case of
malfunction due to breaking of the main
diaphragm or as a result of a lack of impulse
downstream, the regulator will open up
completely.

The mod. IPR pressure regulators are top


entry type, which allows for maintenance
operations without having to remove the
body from the pipes.
Modular device allows for variation in its
configuration even when already installed
in stream. In addition, the modules can be
easily disassembled for eventual controls.
Technical features

body

- spheroidal cast iron GJS 40-18U LT


- steel ASTM A352 LCB
covers
- aluminium (EN AB 46100)
- steel (UNI EN 10028)
diaphragms synthetic rubber with cloth reinforcement
seats
stainless steel
springs
stainless steel
counterbalanced regulating device
diaphragm shock adsorber (on IPR 300 & 600)
built-in shut-off valve
built-in relief valve (on IPR 75 & 150)
anti-pumping device
large range of regulated pressure
prompt action

Diameters
Connections

IPR B 75

IPR B 150

1" x 1"

1" x 1"1/2

Outlet pressure range

IPR B 600

DN32

DN40

[bar]

5 & 19

[mbar]

10 4000

Regulating class

RG

[%]

up to 5

Closing pressure class

SG

[%]

up to 10

Working temperature

[C]

-20 60

Valve Coefficient

Cg

160

DN40

DN50

PN 16 & PN 25 (UNI2240)
ANSI 150 RF (B 16.5)

Rp (ISO 7/1)

Maximum inlet pressure

IPR B 300

281

459

574

928

1160

Rev. 02 del 01/01/2006

IPR -B
Versions available

Dimensioning

.BP

The choice of the regulator is made using the Cg


valve coefficient .
Cg coefficient is numerically equivalent to the value
of air flow in Scfh in critical conditions with full open
regulator operating with an upstream pressure of 1
psia and a temperature of 15 C.
Flow rates with maximum opening at different
operating conditions can be calculated as follows:

for an inlet pressure range of 0,5 5 bar


for an outlet pressure range of 10 150 mbar

.MP
for an inlet pressure range of 0,5 5 bar
for an outlet pressure range of 150 500 mbar

.AP

in non critical conditions (when Pe < 2 Pa )

a.

for an inlet pressure range of 0,5 5 bar


for an outlet pressure range of 500 4000 mbar

( Pe Pa)

Q = 0,526 * Cg * Pe * sin 93,5 *

Pe

.APS (non counterbalanced)

for an inlet pressure range of 2 19 bar


for an outlet pressure range of 500 4000 mbar

b.

.APA

for an inlet pressure range of 2 19 bar


for an outlet pressure range of 500 4000 mbar

in critical conditions (when Pe 2 Pa )

Q = 0,526 * Cg * Pe
where :
Q = capacity [Stm3/h]
Pe = absolute upstream pressure [bar]
Pa = absolute downstream pressure [bar]

H
1 x
1 x 1
11/2

DN 32

E
DN 40

DN 50

-B 150
-B 300
-B 600

[ mm. ]

100
130
183

weight

version

[ mm. ]
-B 75

223
223

254

Deg

220 385

90

135

220 385

90

135

400 450 151 240

175

400 460 165 250

175

189
BP
189
BP
310
BP
310
BP

189
MP
189
MP
310
MP
310
MP

[Kg.]

189 TR
AP - APS
189 TR
AP - APA
232
AP - APA
232
AP - APA

4,5
4,5
25
32

Rev. 02 del 01/01/2006