8314
Pressure transmitter
Ceramic measurement cell
Two-wire version
Compact, stable construction for the highest
operational reliability
Type 8314 can be combined with...
Media stop system if bursting pressure exceeded
Type 8624
Type 2712
Type 0911
PI controller
Continuous control
valve
Process indicator
PLC
The compact pressure transmitter Type 8314 meets the highest requirements with regard to mechanical loading, EMC characteristics and operational
reliability and is particularly suitable for demanding industrial applications.
General data
Electrical data
Body material
Stainless steel 1.4305 AISI 303
Power supply (U)
8 up to 33 V DC, unregulated
Wetted parts
materials
Ceramics (Al2O3), stainless steel 1.4305
(1.4404 AISI 316L on request), FKM seal, PPS
Output signal (two-wire)
Standard 4 up to 20 mA signal
Electrical connection
M12 x 1 plug
Load in
< (U - 8 V) / 0.02 A
Process connection
G 1/4 external to DIN 3852 Form E
Protected
connection
Short-circuit proof & protected against
reversal polarity
Installation
as required, preferably with pressure
connection in downward position
Measurement
principle
Ceramic technology
Measurement
procedure
Relative pressure measurement
Measuring range
0 up to 1, 4, 6, 10, 16, 40 or 100 bar
Overload
3 x full scale at 0 ... 4 bar
2.5 x full scale at 6 ... 100 bar
Bursting pressure
3 x full scale at 0 ... 4 bar
2.5 x full scale at 6 ... 100 bar
patented media stop system to prevent
escape of media if the bursting pressure
range is exceeded ( 4 bar nominal pressure)
Fluid temperature
5F up to 257F (-15C up to +125C)
Accuracy
Sum of linearity, hysteresis and reproductibility: 0.3% of F.S.*
Balancing accuracy of zero point and full
scale: 0.3% of F.S.*
Long term stability
0.5% of F.S. / 10 year
Dynamic response
Suitable for static and dynamic measurements
response time < 2 ms, typ. 1ms
Environment
Ambient temperature
5F up to 185F (-15C up to +85C)
Temperat. coefficient
< 0.015% of F.S.* / C (Tcoef. zero point and sensitivity)
Standard and approvals
Protection class
IP67
Interference
emission
Acc. to EN 50081-1 and EN 55022
Interference stability
Acc. to EN 50082-2
* F.S. = full scale
www.burkertusa.com
p. /2
8314
Dimensions [mm]
Electrical connections
2-wires
(4-20 mA)
IN +
G 1/4
18.8 0.1
SW 21
1
12
4
3
56
2.1
OUT
Ordering chart transmitter Type 8314 and accessories
550 364
0 to 4
550 365
0 to 6
552 954
0 to 10
550 366
0 to 16
552 955
0 to 40
550 367
0 to 100
550 368
10
0
Further versions on request
15
20
bar
Pressure
Other measuring ranges
Accessories
Port connection
NPT 1/4
Electrical connection
connectors
Additional
electrical outputs
Item no.
Item no.
0 to 1
Description
G 1/4
Pressure
range [bar]
Process
connection
Transmitter
5-pin M12 female cable connector
with palstic threaded locking ring
917 116
5-pin M12 female connector moulded
on cable (2 m, shielded)
438 680
EMC acc. to harmonised standards for interference resistance EN 50082-2, IEC 61000-6-2 and
EN 61326-1, interference radiation EN 50081-1, EN 55022, CISPR 22, EN 61326-1
Interference stability
Test Norm / Test condition
Effects
Electro-static discharge
ESD
EN 61000-4-2
15 kV air, 89 kV contact discharge
No effects
High frequency electro-magnetic irradiation
EN 61000-4-3
200 V/m, 80 ... 100 MHz
No effects
Line related high frequency coupling
EN 61000-4-6
30 V, 0.15 ... 80 MHz
No effects
Fast transients (Bursts)
EN 61000-4-4 / 4 kV
No effects
Magnetic fields
EN 61000-4-8 / 30 A/m, 50 Hz
No effects
Surge voltage
EN 61000-4-5 / Line-Line, Line-Case
500V, 12 Ohm, 9 F
Radiometric Line-Line 500V, 2 Ohm, 18 F
No failure
Insulation voltage
500 V DC (optional 1000 V DC)
350 V AC (optional 700 V AC)
No effects
Interference transmitted
Test standard / Test condition
Effects
Line - related interference
EN 55022
Interference
0.15 ... 30 MHz
No emission
Radiation from body
30 ... 1000 MHz, 10 meter
No emission
Test / Admissions
Shock acc. IEC 28-2-27
75G, 11 ms half sine wave, all three directions. Free fall from 1 m on concrete (6x)
Constant schock acc. IEC 68-2-29
40G for 6 ms, 1000 x all three directions
Vibration acc. IEC 68-2-6
20G, 9...200 Hz, 2...9 Hz with amplit. +/- 15 mm, 1 Octave/min all three directions,
50 constant load
To find your nearest Burkert facility, click on the orange box
In case of special application conditions,
please consult for advice.
p. /2
www.burkert-usa.com
We reserve the right to make technical
changes without notice.
0612/3_US-en_1000082477