X-Shield SF Primer is a high-performance, solvent-free primer suitable for use with epoxy coatings and floor systems. It has advantages such as meeting VOC limits, being formaldehyde-free, having low viscosity and penetrating surfaces well to enhance bonding. The primer has a pot life of 60 minutes, dries in 3 hours, and can be recoated within 6-24 hours. It should be applied in a single 100 micron wet coat by roller, brush or airless spray. Surface preparation requires cleaning and profile grinding to CSP 4-5 prior to moisture testing and application of the primer.

Uploaded by

Ahmed Taha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
214 views2 pages

X-Shield SF Primer PDF

X-Shield SF Primer is a high-performance, solvent-free primer suitable for use with epoxy coatings and floor systems. It has advantages such as meeting VOC limits, being formaldehyde-free, having low viscosity and penetrating surfaces well to enhance bonding. The primer has a pot life of 60 minutes, dries in 3 hours, and can be recoated within 6-24 hours. It should be applied in a single 100 micron wet coat by roller, brush or airless spray. Surface preparation requires cleaning and profile grinding to CSP 4-5 prior to moisture testing and application of the primer.

Uploaded by

Ahmed Taha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Technical Data Sheet

X-Shield SF Primer
High performance primer for epoxy coating and floor systems
Product Description
X-Shield SF Primer is a high penetration primer suitable for
use with a wide range of epoxy coatings and floor
systems.
Advantages
Meets SCAQMD Rule 1113 & LEED VOC Limits
Formaldehyde free
Low viscosity
Solvent free
Penetrating
Enhances bond
Stops out gassing
Specification Compliance
SCAQMD Rule 1113
LEED NC2009 IEQ 4.2

30260413

Application Guidelines
Epoxy coating and floor systems should be applied by
experienced coating crews. X-Calibur provides detailed
method statements on all its products for use in various
applications. These must be referred to prior to starting
work. The information below is a summary intended for
guidance only.
Surface Preparation
The substrate must be structurally sound. Loose
or unsound concrete should be removed and made good.
Surfaces must be entirely free of oil, grease, paint, corrosion deposits, dust, laitance or other surface deposits.
The surface should be prepared by captive blasting to
produce a lightly exposed aggregate surface i.e. a ICRI
CSP 4 or 5 surface profile. Any bug holes (blow holes)
should be filled with X-Shield BugFill or X-Shield Primer
Filler.

Laboratory Test Data


Property

Typical Results
100%

Volume solids
Specific gravity

1.05 0.05

Pot life

60 mins at 30C (86F)

Touch dry

3 hours at 30C (86F)

Recoat time

6 to 24 hours at 30C (86F)

Volatile Organic Content


VOC = 0 g/L
Theoretical Coverage
X-Shield SF Primer 10m per liter (110ft2 per quart).
Actual coverage will depend on wastage and surface
profile and can be up to 30% or more higher than
theoretical coverage.
Packaging
1, 5 and 15 liter packs
1 quart and 1 gallon packs - USA.
Shelf Life
18 months when stored below 30C (86F) under shade in a
dry environment.

Moisture Testing
The concrete slab should be tested for moisture with the
Rapid RH system following the procedure in ASTM
F2170. If the humidity reading is greater than 80% then
conduct moisture vapor emission rate (MVER) testing
using the procedure in ASTM F1869. (Both test kits are
available for purchase from X-Calibur). If the MVER is
under 3lbs/1000ft2/24h use X-Shield SF Primer. If the
MVER is 3 to 5 lbs/1000ft2/24h use a single coat X-Shield
MT Primer at 165 microns wft. If the MVER is 5 to 12
lbs/1000ft2/24h use two coats of X-Shield MT Primer at
200 microns wft per coat.
Mixing
Mix X-Shield SF Primer using the following technique.
Add the hardener Part B into the base Part A and mix
using a slow speed drill (500 rpm) with an X-Shield
Coating Mixer Paddle for 3 minutes or until both
components have fully dispersed and are uniform in
color. Be sure to rotate the mixer throughout the drum.
Mix only full packs.
Application
Apply a single coat of 100 micron (4mils) wet film
thickness using brush, roller or airless spray.
When using airless spray, tip size should be 0.015 to
0.0018 at a pressure of 2200psi. Allow to dry before
over coating. Ensure that no ponding of the primer

occurs and that it is not applied too thick. Recoat after 6


to 24 hours at 30C (86F). If the primer is left to dry for
more than 24 hours the surface will have to be
re-primed. Porous substrates may require a two coat
application. Clean equipment using X-Shield Solvent S.
Limitations
Will not accommodate movement cracks.
Do not be apply within 3C of the dewpoint or if it is
within 5C of the dewpoint and dropping.
Avoid excessive application.
Avoid skin contact.
Do not discard into the water system.
Health and Safety
This product is for industrial use only by trained
operatives. It is potentially hazardous if not used
correctly. Please refer to the Material Safety Data
Sheet (MSDS) prior to the purchase and use of
this product. The MSDS can be obtained via our
website www.x-calibur.us

Warranties
X-Calibur supplies products that comply with the
properties shown on the current datasheets. In the
unlikely event that products supplied are proved not to
comply with these properties, then we will replace the
non-compliant product or refund the purchase price.
X-Calibur does not warrant or guarantee the installation
of the products as it does not have control of the
installation or end use of the products. Any suspected
defects must be reported to X-Calibur in writing within
five working days of being detected. X-Calibur
Construction Systems Inc. makes no warranty as to
merchantability or fitness for a particular purpose
and this warranty is in lieu of all other warranties
express or implied. X-Calibur Construction Systems
Inc. shall not be liable for damages of any sort including
remote or consequential damages, down time, or delay.

Authorized Technical Specialist


Please note that only X-Calibur Authorized Technical
Specialists (ATSs) are permitted to change any of the
information in this data sheet or to provide written
recommendations concerning the use of this product.
Visit www.x-calibur.us for a full list of X-Calibur ATSs.
Datasheet Validity
X-Calibur makes modifications to its product datasheets
on a continuous basis. Please check the datasheet
update section on www.x-calibur.us to ensure you have
the latest version.

www.x-calibur.us

You might also like