Frymaster GF14 Service & Parts Manual
Frymaster GF14 Service & Parts Manual
Frymaster GF14 Service & Parts Manual
APRIL 2009
*8195888*
NOTICE
This appliance is intended for professional use only and is to be operated by qualified
personnel only. A Frymaster/DEAN Factory Authorized Service Center (FASC) or other qualified
professional should perform installation, maintenance, and repairs. Installation, maintenance,
or repairs by unqualified personnel may void the manufacturers warranty. See Chapter 1 of
this manual for definitions of qualified personnel.
NOTICE
This equipment must be installed in accordance with the appropriate national and local codes of
the country and/or region in which the appliance is installed. See NATIONAL CODE
REQUIREMENTS in Chapter 2 of this manual for specifics.
DANGER
Adequate means must be provided to limit the movement of this appliance without depending
upon the gas line connection. Single fryers equipped with legs must be stabilized by installing
anchor straps. All fryers equipped with casters must be stabilized by installing restraining
chains. If a flexible gas line is used, an additional restraining cable must be connected at all
times when the fryer is in use.
DANGER
Do not stand on the fryer. Serious injury can result
DANGER
Do not store or use gasoline or other flammable liquids or vapors in the vicinity of this or any
other appliance.
DANGER
Instructions to be followed in the event the operator smells gas or otherwise detects a gas leak
must be posted in a prominent location. This information can be obtained from the local gas
company or gas supplier.
DANGER
This product contains chemicals known to the state of California to cause cancer and/or birth
defects or other reproductive harm.
Operation, installation, and servicing of this product could expose you to airborne particles of
glasswool or ceramic fibers, crystalline silica, and/or carbon monoxide. Inhalation of airborne
particles of glasswool or ceramic fibers is known to the State of California to cause cancer.
Inhalation of carbon monoxide is known to the State of California to cause birth defects or other
reproductive harm.
1.1
Functional Description
The GF14 and GF40 Series fryers contain a welded steel (stainless or cold-rolled) frypot that is
directly heated by gas flames that are diffused evenly over its lower surface by deflectors. In GF14s,
each deflector is made of a single piece of stainless steel; in GF40s, the deflectors are comprised of a
ceramic target attached to a stainless steel bracket. The rear deflector on both fryers consists of a
box-like mount that is attached to the flue assembly on the back of the fryer. As with the deflectors
on the burner assembly, the rear deflector on GF40 fryers has a ceramic target.
GF40 Fryers have ceramic "targets"
attached to stainless steel brackets.
GF14 Fryers have stainless steel
deflectors without ceramics.
The flames originate from orifices in a U-shaped burner manifold positioned beneath the frypot.
The orifice diameters differ for natural and Propane (LP) gas and for fryers as indicated in the
accompanying table (NOTE: This table shows only the orifices used in elevations up to 1999
feet/609 meters. See Chapter 2 (GF14) or Chapter 3 (GF40) for orifices required at other
elevations). GF14 fryers have one orifice per deflector; GF40 fryers have two orifices per deflector
assembly.
GF14/GF40 Series Orifice Sizes (0-1999 ft/609 m)
Fryer & Gas Type
Inches
Millimeters
GF14 Natural
0.065
1.65mm
GF14 Propane (LP)
0.041
1.05mm
GF40 Natural
0.057
1.45mm
GF40 Propane (LP)
0.034
0.86mm
An electromechanical millivolt gas valve regulates gas flow to the burner manifold. GF14/GF40
fryers use a pilot ignition system to control burner firing.
1-1
DANGER
Moving a fryer filled with cooking oil/shortening may cause spilling or splattering of
the hot liquid. Follow the draining instructions in Chapter 3 of the Installation and
Operation manual before attempting to relocate a fryer for servicing.
1. Drain all cooking oil/shortening from the fryer.
2. Shut off the gas supply to the unit and disconnect the unit from the gas supply.
3. Remove any attached restraining devices.
4. Relocate the fryer for service accessibility.
5. After servicing is complete, reconnect the unit to the gas supply and reattach the restraining
devices.
6. Refill the frypot with cooking oil/shortening.
1.3
1-2
Refer to Quarterly Checks and Services in Chapter 4 of the Installation and Operation manual.
1.4
Refer to Semi-Annual Checks and Services in Chapter 4 of the Installation and Operation manual.
1.5
DANGER
Drain the frypot or remove the handle from the drain valve before proceeding further.
Proper spacing of the edge of the deflectors is -inch (19mm) from the frypot side. To adjust target
spacing, bend the brackets to which they are attached away or toward the frypot to the proper
distance. (A length of board of the proper thickness is useful as a gauge to verify spacing and
alignment.) The illustration below depicts a typical GF40. The GF14 procedure is the same except
that there are no ceramic targets.
Frypot Side
.75-inch
(19mm)
Deflector
Edge
1.6
1. Remove the cap shown in the illustration below to access the pilot flame adjustment screw in the
gas valve.
1-3
2. Using a small, flat-tipped screwdriver, turn the pilot flame adjustment screw counterclockwise to
increase the length of the flame or clockwise to decrease the length of the flame. Adjust the
flame to a length of 1 to 1 inches (25 to 38 mm).
3. Reinstall the pilot flame adjustment screw cap.
1.7
1-4
Compression Nut
Thermostat Bulb
Capillary Tube
Large fitting screws
into frypot.
Attach wire 2C to
this terminal.
Attach wire 1C to
this terminal.
7. Position the thermostat bulb in the retaining clips and fold the clips down to secure it in place.
8. Gently form the capillary tube so that it lies close to the bottom surface and front wall of the
frypot, working any slack out through the fitting (see illustration above).
9. Tighten the capillary tube compression fitting and carefully coil the excess capillary tubing as
shown in the illustration on Page 1-4. Mount the thermostat control to the mounting bracket
using the screws removed in Step 4.
10. Connect the wires disconnected in Step 3 above to the thermostat as shown in the illustration on
Page 1-4.
11. Install the thermostat knob on the shaft of the thermostat control.
1-5
Attach hi-limit
wires to these
terminals.
Polarity does
not matter.
2.
Disconnect the wires from the gas valve terminal block, marking each wire to facilitate
reconnection.
3.
Disconnect the pipe union collar at the right side of the gas valve.
4.
On GF40 fryers, remove the burner heat shield hanger screws at the front of the burner and
remove the heat shield.
5.
Remove the burner hanger screws and lower the front of the burner assembly. Pull it forward to
clear the rear burner hanger, then lower the burner to the floor of the cabinet. Carefully pull the
burner assembly from the cabinet.
6.
GF14: Use a -inch box end wrench to remove the brass orifice that holds the deflector to the
burner manifold. Position the new deflector and reinstall the orifice.
GF40: To replace only the ceramic targets, straighten the target locking tab with a pair of
needle nose pliers or a screwdriver and slide the target up and off the bracket. Recover the
insulation from the old target and install with the replacement ceramic. Slide the replacement
target onto the bracket, then position the insulation in the opening between the bracket and the
ceramic. Bend the locking tab down to secure ceramic in place (see illustration below).
Bend this tab up
to release
ceramic and
insulation. When
new ceramic and
insulation have
been positioned
in bracket, bend
the tab down to
secure them in
place.
1-6
To replace the entire target assembly, use a -inch box end wrench to remove the brass orifices
that hold the assembly to the burner manifold. Position the new assembly and reinstall the
orifices.
WARNING
Use extreme care to prevent cross-threading and stripping when reinstalling the
brass orifices.
7. Reverse steps 1-5 to reinstall the burner assembly. Check spacing and alignment of targets in
accordance with Section 1.6.
1.7.4 Replacing the Gas Valve
DANGER
Drain the frypot or remove the handle from the drain valve before proceeding further.
1. Disconnect fryer from the gas supply.
2. Disconnect the wiring from the gas valve terminal block, marking each wire to facilitate
reconnection.
3. Disconnect the pilot gas line fitting from the gas valve and remove the vent tube.
4. GF14: Disconnect the pipe union to the right of the gas valve and rotate the valve assembly
outward just enough to allow the valve to be unscrewed from the burner manifold piping.
GF40: Disconnect the pipe unions at each side of the gas valve and remove the valve from the
assembly.
5. Remove the fittings from the old gas valve and install them on the replacement valve, using
Loctite PST56765 or equivalent pipe thread sealant on threads. Install the vent tube removed
from the old valve. DO NOT use thread sealant on the vent tube.
6. Reverse steps 1-4 to install the replacement valve, reconnecting the wiring in accordance with
the wiring diagram on the door of the fryer or with the notes made in Step 2. Return the fryer to
operation and check the burner manifold pressure in accordance with the procedure in the SemiAnnual Checks and Services of Chapter 4 of the Installation and Operation manual.
1.7.5 Replacing the Thermopile or Pilot Assembly
DANGER
Drain the frypot or remove the handle from the drain valve before proceeding further.
A pair of small screws (see illustration below) attaches the pilot assembly, which consists of the
pilot and the thermopile, to the burner manifold.
1-7
Mounting Screws
1. To replace only the thermopile, disconnect the leads from the gas valve, remove the guard, bend
the clip at the bottom of the pilot assembly outward, and press the thermopile out of the
assembly from the top. Reverse the procedure to install the replacement thermopile.
3: Press down on top of thermopile,
forcing it out of the pilot bracket.
1: Remove these screws
to release guard.
This section is intended to provide technicians with a general knowledge of the broad problem
categories associated with this equipment, and the probable causes of each. With this knowledge, the
technician should be able to isolate and correct any problem encountered.
Problems you are likely to encounter can be grouped into these broad categories:
1. Pilot failures
2. Improper burner functioning
3. Improper temperature control
1-9
4. Leaking
The probable causes and corrective actions for each category are discussed in the following sections.
1.8.1 Pilot Failures
Pilot failures fall into one or the other of two categories failure to light or failure to remain lit.
Pilot Fails to Light
1. Gas is not being supplied to the valve: Check for a closed gas cutoff valve upstream of the gas
valve. Also verify that the gas line quick disconnect fitting at the rear of the fryer (if so
equipped) is properly connected.
2. Blocked pilot orifice: If gas is reaching the valve but the pilot will not light, check for an
obstruction in the pilot orifice, especially in new installations. If the orifice is clear, check to be
sure that the pilot adjustment screw is not completely closed.
Pilot Does Not Remain Lit When Gas Valve Knob is Released
The electromechanical Honeywell gas valve used on the GF14 and GF40 fryers has a pair of
normally open coils (electromagnetic switches) that close when low voltage is applied to them. If
the coils do not close, the valve will not open to supply gas to the pilot or to the burner manifold.
Turning the gas valve knob to the pilot position and pressing it in bypasses the pilot coil, allowing
the pilot to be lighted. The pilot flame heats the thermopile, which generates the voltage required to
close the coils. If the pilot flame goes out when the knob is released, there are four probable causes:
1. Open or grounded high-limit: The high-limit thermostat functions as a normally closed
switch. If the high-limit is open or grounded, the gas valve coil will not pull in and no gas will be
supplied to the pilot or to the burner manifold.
Check and Corrective Action: Detach the high-limit leads from the gas valve and check for
continuity. If the high-limit fails the continuity check, it must be replaced.
2. Loose/corroded wiring connections on high-limit or thermopile: This has the same effect as
an open or grounded high-limit. If the gas valve coils do not receive the appropriate voltage
from the thermopile, they will not close and no gas will be supplied to the pilot or to the burner
manifold.
Check and Corrective Action: Check wiring connections for corrosion and tightness. Check
terminals to verify that they are securely attached to their leads.
3. Low or no voltage out of thermopile: If the tip of the thermopile is not surrounded by the pilot
flame, it will not generate sufficient voltage to the gas valve coils for them to close. No gas will
be supplied to the pilot or to the burner manifold.
Checks and Corrective Actions:
Observe pilot flame through the viewing port in the lower left corner of the frypot front baffle
assembly. If the pilot flame is less than 1-inch (25mm) adjust the pilot flame in accordance with
1-10
Section 1.7. If the flame is being blown away from the pilot, eliminate the draft that is causing it
to be blown away from the thermopile.
If the pilot flame correctly impinges the tip of the thermopile, connect a multimeter in series with
either of the thermopile leads and its gas valve terminal. Light the pilot and allow it to burn for
at least two minutes, then check the voltage output. If voltage is less than 400 millivolts, replace
the thermopile.
4. Malfunctioning gas valve: If either of the coils in the gas valve fails, no gas will be supplied to
the pilot or to the burner manifold.
Check and Corrective Action: If all the above checks are satisfactory, the gas valve has failed.
Replace the gas valve.
1-11
1-12
Thermopile
1C
2C
Operating Thermostat
1-13
High-Limit Thermostat
1C
2C
Operating Thermostat
Thermopile
1-14
8
2
6
Item
1
2
3
4
5
*
6
Part #
803-0015
803-0032
803-0197
803-0271
806-5518
910-7014
810-0070
810-0073
7
810-0072
810-0074
8
810-0083
810-0084
810-0088
810-0085
9
826-1095
*
826-0900
*
812-1226
* Not illustrated.
Component
Basket, Full
Rack, Basket Support
Cleanout Rod, 27-Inch
Basket, Twin
Cover, Frypot
Cover, Spreader Cabinet
Quick-Disconnect Fitting, Female
-inch
1-inch
Quick-Disconnect Fitting, Male
-inch
1-inch
Hose, Flexible Gas
-inch x 36-inch
-inch x 48-inch
1-inch x 36-inch
1-inch x 48-inch
Anchor Strap Kit (for use only on fryers equipped with legs)
Chain Restraint Kit (for use only on fryers equipped with casters)
Drain Extension
2-1
27
2-2
8
10
14
13
28
16
12
18
20
17
15
26
21
25
11
17
23
24
19
22
Item
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
Part #
200-0176
200-0177
200-0749
807-1603
807-1604
809-0092
809-0105
809-0173
809-0785
809-0951
826-1398
812-1223
812-0907
812-1204
826-1357
826-1386
826-1354
810-0135
826-1391
812-0906
812-0915
812-0910
810-0691
810-0703
810-1862
810-2071
810-2070
813-0022
813-0031
813-0062
813-0068
813-0087
813-0108
813-0154
813-0165
813-0173
813-0265
813-0460
813-0584
900-1032
910-1082
Component
Bracket, Front Manifold Mounting
Hanger, Rear Manifold
Guard, Thermopile
Valve, Honeywell Millivolt Gas (See NOTE 1.)
Natural (See NOTE 2.)
Propane (See NOTE 2.)
Screw, 5-40 x -inch Slotted Pan Head
Screw, #8 x -inch Slotted Hex Washer Head
Clip, Tinnerman
Screw, #14 x -inch Slotted Hex Washer Head
Clamp, Hose
Orifice
1.65 mm (for natural gas, 0-1999 feet/0-609 meters) (package of 10)
1.60 mm (for natural gas, 2000-3999/610-1219 meters)
1.55 mm (for natural gas, 4000-5999 feet/1220-1829 meters)
1.50 mm (for natural gas, 6000-7999 feet/1830-2438 meters)
1.45 mm (for natural gas, 8000-8999 feet/2439-2743 meters) (pkg of 10)
1.40 mm (for natural gas, 9000-9999 feet/2744-3048 meters) (pkg of 10)
1.05 mm (for Propane gas, 0-1999 feet/0-609 meters) (package of 10)
1.02 mm (for Propane gas, 2000-3999/610-1219 meters)
0.99 mm (for Propane gas, 4000-5999 feet/1220-1829 meters) (pkg of 10)
0.95 mm (for Propane gas, 6000-7999 feet/1830-2438 meters)
0.93 mm (for Propane gas, 8000-8999 feet/2439-2743 meters)
0.90 mm (for Propane gas, 9000-9999 feet/2743-3048 meters)
Tube, Gas Valve Vent
Gas Line, .25-inch x 17.50-inch
Manifold, Burner
Pilot Assembly (Includes bracket, hood, and thermopile. See NOTE 3.)
Natural Gas w/.024-inch Orifice 810-0149
Propane Gas w/.013-inch Orifice 810-0148
Nipple, -inch x Close BM NPT
Bushing, -inch x -inch BM NPT Reducer
Elbow, -inch x 90 BM NPT
Elbow, -inch x -inch BM NPT Reducer
Nipple, -inch x 1.50-inch BM NPT
Nipple, -inch x 24.50-inch BM NPT
Plug, -inch Hex Head Pipe
Elbow, -inch x 90 BM NPT Street
Union, -inch BM NPT
Nipple, -inch x 2.50-inch BM NPT
Nipple, -inch x 3.00-inch BM NPT
Reducer, --inch x -inch Bell
Bracket, Pilot Mounting
Deflector, GF14
2-3
2-4
3
26
27
17
11
21
15
16
24
14
19
18
22
12
20
10
13
23
10
25
10
CABINETRY COMPONENTS
Item
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
Part #
210-0384
806-3811
806-8396
826-1351
826-1362
809-0171
809-0191
809-0193
826-1371
826-1374
809-0413
809-0563
810-1105
810-1403
810-1508
824-0330
900-0943
900-1501
900-7131
900-7270
900-7312
910-3207
900-7310SP
910-7310SP
24
901-7311SP
911-7311SP
25
26
27
902-7311SP
912-7311SP
810-1422
826-1379
Component
Cap, Flue
Leg (set of 4)
Door Assembly
Retainer, Nut (Nutsert) (package of 10)
Nut, -20 Hex (package of 10)
Thumbscrew, -20 x 1-inch
Washer, -inch Lock
Washer, -inch Nylon Flat
Screw, #8 X -inch Hex Head Drill Point (package of 25)
Screw, #10 X -inch Hex Head (package of 25)
Spacer, -inch X .160-inch 8 Gauge Nylon
Bolt, -20 x -inch Carriage
Magnet, Offset Door
Hanger, Wireform Basket (for old-style extruded aluminum use 803-0028)
Hinge, Universal Door
Panel, GF14/GF40 Control
Bracket, Drain Extension
Mount, Thermostat
Support, Back
Base, One-Piece GF14 Cabinet
Brace, Cabinet Top
Deflector, Flue Exhaust
Back, Cabinet
Enameled Steel
Stainless Steel
Side, Left Cabinet
Enameled Steel
Stainless Steel
Side, Right Cabinet
Enameled Steel
Stainless Steel
Handle, Wireform Door
Screw, #10 X -inch Phillips Truss Head (package of 10)
2-5
2-6
18
3
4
17
19
13
12
11
15
11
13
14
17
16
10
20
Item
1
2
*
*
*
3
4
5
6
7
8
9
10
11
12
13
14
15
Part #
806-3958SP
806-3959SP
806-9710SP
806-4006
826-1177
807-1692
816-0578
816-0139
806-7972
826-1362
809-0190
809-0362
809-0409
809-0410
810-0647
810-1569
812-0169
812-0170
812-0481
812-0482
812-0483
826-1618
826-1617
823-2874SP
16
823-1024
17
823-1025
18
900-1090
19
900-3860
20
910-2113
* Not Illustrated.
Component
Complete Replacement Frypot with Flue and Insulation Installed
Stainless Steel
Cold-Rolled Steel
Stainless Steel (for SYSCO fryers w/Fenwal thermostat only)
Complete Front Combustion Chamber (Items 6, 8, 12, and 19)
Thermostat Assembly, High Limit
Thermostat, Sunne Operating
O-Ring, Thermostat Shaft
Knob, Thermostat Control
Thermostat, Fenwal Operating (for use in SYSCO fryers only)
Nut, -20 Hex (package of 10)
Washer, -inch Flat
Screw, #8 X 1-inch Hex Washer Head Drill Point
Screw, #10 X -inch Round Head One-way Security
Screw, #8 X -inch Phillips Head Drill Point
Holder, Security Screw
Valve, 1.25-inch Drain
Insulation, Banroc 12.00 X 1.75 X 1.00-inch
Insulation, Banroc 16.88 X 1.25 X 1.00-inch
Insulation, Front Combustion Chamber
Insulation, Side Combustion Chamber
Insulation, GF14 Frypot Rear
Replacement Frypot without Insulation
Stainless Steel
Cold-Rolled Steel
For use in SYSCO fryers using Fenwal operating thermostat only.
Flue
Side, Combustion Chamber
Cover, Pilot Viewport
Front, Combustion Chamber
Target, GF14 Rear
2-7
8
2
6
Item
1
2
3
4
5
*
6
Part #
803-0099
803-0132
803-0197
803-0271
806-5518
910-7014
810-0070
810-0073
7
810-0072
810-0074
8
810-0083
810-0084
810-0088
810-0085
9
826-1095
*
826-0900
*
812-1226
* Not illustrated.
Component
Basket, Full
Rack, Basket Support
Cleanout Rod, 27-Inch
Basket, Twin
Cover, Frypot
Cover, Spreader Cabinet
Quick-Disconnect Fitting, Female
-inch
1-inch
Quick-Disconnect Fitting, Male
-inch
1-inch
Hose, Flexible Gas
-inch x 36-inch
-inch x 48-inch
1-inch x 36-inch
1-inch x 48-inch
Anchor Strap Kit (for use only on fryers equipped with legs)
Chain Restraint Kit (for use only on fryers equipped with casters)
Drain Extension
3-1
23
22
10
5
16
11
17
3-2
13
14
18
19
15
18
20
21
14
12
12
Item
1
2
3
4
*
5
6
7
8
9
10
Part #
200-0749
806-0225SP
807-1603
807-1604
809-0092
809-0115
809-0785
809-0951
826-1357
826-1386
810-0361
810-0131
810-0951
810-0323
826-1387
810-0952
826-1352
812-0914
812-1302
812-0444
810-0691
810-0705
810-1830
810-1773
11
813-0031
12
813-0062
13
813-0068
14
813-0087
15
813-0108
16
813-0154
17
813-0165
18
813-0173
19
813-0247
20
813-0265
21
813-0320
22
823-0496
23
823-0574
* Not illustrated.
Component
Guard, Thermopile
Deflector Assembly
Valve, Honeywell Millivolt Gas (See NOTE 1.)
Natural (See NOTE 2.)
Propane (See NOTE 2.)
Screw, 5-40 x -inch Slotted Pan Head
Screw. #10-32 x -inch Truss Head (attaches Item 10 to Item 22)
Screw, #14 x -inch Slotted Hex Washer Head
Clamp, Hose
Orifice
1.45 mm (for natural gas, 0-1999 feet/0-609 meters) (package of 10)
1.40 mm (for natural gas, 2000-3999 feet/610-1219 meters) (pkg of 10)
1.36 mm (for natural gas, 4000-5999 feet/1220-1829 meters)
1.30 mm (for natural gas, 6000-7999 feet/1830-2438 meters)
1.25 mm (for natural gas, 8000-8999 feet/2439-2743 meters)
1.20 mm (for natural gas, 9000-9999 feet/2744-3048 meters)
0.86 mm (for Propane gas, 0-1999 feet/0-609 meters) (package of 10)
0.82 mm (for Propane gas, 2000-3999/610-1219 meters)
0.81 mm (for Propane gas, 4000-5999 feet/1220-1829 meters) (pkg of 10)
0.78 mm (for Propane gas, 6000-7999 feet/1830-2438 meters)
0.76 mm (for Propane gas, 8000-8999 feet/2439-2743 meters)
0.74 mm (for Propane gas, 9000-9999 feet/2743-3048 meters)
Tube, Gas Valve Vent
Gas Line, .25-inch x 23.00-inch
Pilot Assembly (Includes bracket, hood, and thermopile. See NOTE 3.)
Natural Gas w/.024-inch Right Angle Orifice 810-0149
Propane Gas w/.013-inch Right Angle Orifice 810-0148
Bushing, -inch x -inch BM NPT Reducer
Elbow, -inch x 90 BM NPT
Elbow, -inch x -inch BM NPT Reducer
Nipple, -inch x 1.50-inch BM NPT
Nipple, -inch x 24.50-inch BM NPT
Plug, -inch Hex Head Pipe
Elbow, -inch x 90 BM NPT Street
Union, -inch BM NPT
Nipple, -inch x 3.50-inch BM NPT
Nipple, -inch x 2.50-inch BM NPT
Nipple, -inch x 8.00-inch BM NPT
Manifold, Burner
Shield, Open Burner Heat
3-3
27
28
3-4
6
15
21
16
12
17
23
10
14
20
18
11
19
13
26
22
25
24
CABINETRY COMPONENTS
Item
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Part #
806-8396
826-1351
826-1362
809-0171
809-0191
809-0193
826-1371
826-1374
809-0413
809-0563
810-0356
810-0357
810-1105
810-1403
810-1508
824-0330
900-0943
900-1129
900-1501
900-4274
900-5764
900-6983SP
910-6983SP
23
901-7311SP
911-7311SP
24
25
26
27
28
902-7311SP
912-7311SP
910-3557
910-5038
810-1422
826-1379
Component
Door Assembly
Retainer, Nut (Nutsert) (package of 10)
Nut, -20 Hex (package of 10)
Thumbscrew, -20 x 1-inch
Washer, -inch Lock
Washer, -inch Nylon Flat
Screw, #8 X -inch Hex Head Drill Point (package of 25)
Screw, #10 X -inch Hex Head (package of 25)
Spacer, -inch X .160-inch 8 Gauge Nylon
Bolt, -20 X -inch Carriage
Caster w/o Brake, 5 Wheel
Caster w/Brake, 5 Wheel
Magnet, Offset Door
Hanger, Wireform Basket (for old-style extruded aluminum use 803-0028)
Hinge, Universal Door
Panel, GF14/GF40 Control
Bracket, Drain Extension
Support, Gas Line
Mount, Thermostat
Brace, GF40 Cabinet Top
Base, One-Piece GF40 Cabinet
Back, Cabinet
Enameled Steel
Stainless Steel
Side, Left Cabinet
Enameled Steel
Stainless Steel
Side, Right Cabinet
Enameled Steel
Stainless Steel
Deflector, GF40 Flue
Cap, Flue
Handle, Wireform Door
Screw, #10 X -inch Phillips Truss Head (package of 10)
3-5
16
3-6
17
18
13
21
22
23
12
19
20
10
11
14
13
11
12
15
4
8
Item
1
2
3
*
*
4
5
6
7
8
9
10
11
12
13
14
Part #
106-1679SP
806-4199SP
806-4308SP
900-6969
806-5566
806-5567SP
816-0174
816-0175
806-5778SP
826-1362
809-0170
809-0173
826-1371
809-0410
810-0500
812-0248
812-0249
812-0269
823-3470SP
823-1233SP
15
900-6441
16
806-7546
17
826-1809
*
816-0578
*
816-0139
18
810-1569
19
812-0246
20
812-0245
21
900-1090
22
810-0647
23
809-0409
* Not Illustrated.
Component
Complete Replacement Frypot with Flue and Insulation Installed
Stainless Steel
Cold-Rolled Steel
Complete Front Combustion Chamber (Items 1 and 19 through 23)
Baffle, Front Insulation
Panel Assembly, Rear Combustion Chamber
Flue Assembly with Insulation, Complete
Insulation, Flue Back
Insulation, Flue Front
Box Assembly, Flue Deflector
Nut, -20 Hex (package of 10)
Screw, #14 X -inch Slotted Pan Head
Clip, Tinnerman
Screw, #8 X -inch Hex Head Drill Point (package of 25)
Screw, #8 X -inch Phillips Head Drill Point
Spacer, -inch X 15/16-inch
Insulation, Kaowool M-Board 14.50 X15.93 X 0.25-inch
Insulation, Spinglas 16.75 X 19.38 X 1.00-inch
Insulation, Kaowool Blanket 14.00 X 14.00 X 0.50-inch
Replacement Frypot without Insulation
Stainless Steel
Cold-Rolled Steel
Side, Combustion Chamber
Thermostat Assembly, High Limit
Thermostat, Sunne Operating
O-Ring, Thermostat Shaft
Knob, Thermostat Control
Valve, 1.25-inch Drain
Insulation, Spinglas 15.00 X 16.37 X 1.00-inch
Insulation, Kaowool M-Board 15.00 X 16.37 X 0.25-inch
Cover, Pilot Viewport
Holder, Security Screw
Screw, #10 X -inch Round Head One-way Security
3-7
SERVICE HOTLINE
1-800-551-8633
819-5888