ICS3.5 Serial Manager V 1.1.
software manual
2011.07
2011.07
Preface
Thank you for using the ICS3.5 Serial Manager. The purpose of this software is to change the configuration of
ICS3.5 standard servo motor. Before using, please read the following carefully.
Disclaimer
This software is a free software. Redistribution is allowed, but in doing so, please attach this software
manual.
Copyright for the present software, as well as all rights for the designs of icons other than the following
Primo icons and the Kondo Science logo belongs to Kondo Kagaku Co., Ltd.
The present software may not be sold or leased without permission.
Please use the present software at your own personal risk. The creators are not liable for any failures that
may result from using this software.
Specifics of the present software may be changed or modified without prior notice.
The present software may not be disassembled, decompiled, or reverse engineered.
The icons used in the present software are those of Primo Icon Set by Webdesigner Depot
(http://www.webdesignerdepot.com).
Operating Requirements
.NET Framework2.0
Operation on WindowsXP SP2(32bit), WindowsVista(32bit) and Windows7(32bit) have been confirmed.
How to Use
Install/Uninstall
After extracting the file, please confirm that the following files are in the folder.
ICS3.5Manager.exe (executable file)
IcsBaseClass.dll (library file)
ICS3.5 ManagerSoftwareManual.pdf (the file you are reading now)
When uninstalling, delete the entire folder including the extracted files.
Connecting Equipments
Real-time operation (operation test) and various settings of servo are enabled by connecting the
ICS-USB adapter HS No.02043 or the ICS-USB adapter No.01106 to servo and another power
source.
Y harness
ICS-USB adapter HS
A servo motor
An attachment ICS-USB adapter HS
Or ICS-USB adapter
set
A power source
Extension cord
An attachment ICS-USB adapter HS
set
Connect to the Y harness using connection cables accompanying the servo motor.
only one should be connected.
For power, use DC 9V ~ 12V.
internal components.
Basically,
Operation outside this range may cause damage to the servo's
When changing settings of the main unit, the ICS-USB adapter HS and the servo motor can be
directly connected (but not for real-time operation).
Do not set the baudrate to above 115 kbps when using the ICS-USB adapter.
Software Execution
By executing ICS3.5Manager.exe, the following screen appears.
File - Help
FILE ... For saving current settings, reading saved data, and exiting present software.
HELP... Displays version information of the present software.
COM Setting
Set and connect COM port.
Select COM number distributed to ICS-USB adapter HS and baudrate (communication speed); open port
with the "Connect" button.
*COM number can be confirmed using the Device Manager on Windows. For details, see the manual
accompanying ICS-USB adapter HS.
Baudrate may be changed while port is connected.
Besides communication speed, "Auto" is also available in the Baudrate section. This function
automatically matches the servo's communication speed and ID. When this article is selected at a state
of disconnection/connection, automatic reconnection takes place.
Read, Write, Reset
Read and Write EEPROM settings for the servo connected.
The reset button resets the settings on display to the standard condition at software execution. Under this
condition, settings are not written to servo. To reflect settings to servo, press Write.
Display Status
Description of buttons and current status are displayed.
RAM
Changing contents of the servo RAM.
ID --- Write and retrieve ID. (Initial value: 0)
Position --- Operation of servo that is connected.
angle of the servo.
Press the FREE button to obtain the present
Stretch --- The present value of stretch is set and retrieved.
Speed --- The present value of speed is set and retrieved.
Temperature --- The present temperature is retrieved.
"Retrieve" button to retrieve consecutive data.
Check "Real-time" and press the
Current --- The present electric current is obtained. Check "Real-time" and press the "Retrieve"
button to retrieve consecutive data.
[Position] Real-time operation of servo
Servo motor is moved in real-time by operation of the Manager.
Range of Parameter
Around Step
Backward 350011500 Forward
10
Relationship Between
Parameter and Angle of
Position of Servo
Parameter
Angle of Operation
3500
-135Backward
7500
0Neutral
11500
135
Around Step(10)
0.34
[Stretch] [Speed]
Real-time setting change of servo.
Servo motor settings are changed in real-time by operation of the manager.
* This feature is for checking operation. The parameters set at this point will not be written to the
servo.
Range of ParameterStretch
Soft 1 127 Hard
Range of ParameterSpeed
Slow 1 127 Fast
[Temperature] [Current]
Servo motor temperature and electric current are retrieved in real-time by operation of the manager.
Check "Real-time" and press the "Retrieve" button to retrieve consecutive data.
Range of ParameterTemperature
High 1127 Low
Value
Temperrature
73
100
84
95
96
90
108
85
121
80
Range of ParameterCurrent
Forward Low 64 127 High
Backward Low 0 63 High
Forward
Backward
Value
Current
Value
Current
64
0A
0A
64
0.1A
0.1A
69
0.5A
0.5A
74
1.0A
10
1.0A
79
1.5A
15
1.5A
84
2.0A
20
2.0A
Settings
Changes settings within servo (EEPROM).
*
Baudrate --- Sets the baudrate between servo motor and board. (Initial value: 115.2 kbps)
When using ICS-USB adapter, do not change from 115.2 kbps.
Option Flags (Modes) --- Select use of reverse, dedicated serial, slave, and rotate mode.
Stretch --- Changes retention characteristics of the servo motor.
Speed --- Sets the maximum rotation speed of the servo motor.
Punch --- Sets the torque offset when servo motor is in operation.
Dead Band --- Sets neutral band (dead-band) of servo motor.
Response --- Sets the rising characteristics when servo motor is operated.
Dumping --- Sets the outage property of the servo motor.
Protection --- Sets time until protection start-up when output shaft locks.
Limiter --- Specifies maximum operating angle of the servo motor.
Temperature Limit --- Sets the operating point for protective functions in case of temperature
rise.
Current Limit --- Sets the operating point for protective functions in case of current overload.
User Offset --- Sets optional position offset for user.
Version --- Displays firmware version.
[Stretch]
Changes the retention characteristic of the servo motor.
Initial
Range of ParameterStretch
Soft 1 127 Hard
Stretch
SET1
SET2
SET3
60
60
30
90
Stretch (SET1) (SET2) (SET3) are values used in the characteristic change in HeartToHeart3.
[Speed]
Sets the maximum rotation speed of the servo motor.
Initial
Range of ParameterSpeed
Slow 1 127 (Fast)
127
[Punch]
Sets the torque offset when servo motor is in operation.
Initial
Range of ParameterPunch
Low 0 10 High
[Dead Band]
Sets neutral band (dead-band) of servo motor.
Range of ParameterDead Band
Initial
Min 0 10 Max
[Response]
Sets the rising characteristics at operation startup of output shaft.
The smaller the number, the smoother the initial motion appears.
Initial
Range of ParameterResponse
Slow 1 5 Fast
[Dumping]
Sets the braking characteristic of the output shaft at motion stoppage.
The smaller the number, the smoother the motion until stoppage appears.
Initial
Range of ParameterDumping
Slow 1 255 Fast
40
[Protection]
Sets time until protection operation startup.
The protection function is a protective feature for lockup. When in operation, the servo power is
automatically reduced by 50%.
Recovery automatically occurs when lockup is resolved.
Protection is only valid when the servo speed parameter is set to 127.
Range of Parameter
Offset
Per one Parameter
Initial
Short 10 255
Long
0.056 sec
20
[Limiter]
Sets the maximum operation range of servo.
Range of ParameterLimiter
Initial
Limiter Forword
Min 8000 11500 Max
11500Max
Limiter Backword
Min 3500 7500 Max
3500Min
[Temperature Limit]
Set the temperature threshold.
When the sensor mounted on the servo board receives an output larger than the set temperature,
servo goes to a state of weakness. When the temperature decreases below the threshold, motion
is resumed.
Range of ParameterTemperature
High 1 127 Low
Initial
75
102
Temperature
Value
100
73
95
84
90
96
85
108
80
121
[Cu[rrent Limit]
Sets the electric current threshold.
When the sensor mounted on the servo board receives a value larger than the set electric current,
servo goes to a state of weakness. When the current decreases below the threshold, motion is
resumed.
Range of ParameterCurrent
Low 0 63 High
Current
Value
0A
0.1A
0.5A
1.0A
10
1.5A
15
2.0A
20
Initial
40
4.0A
[User Offset]
The user can arbitrarily set the initial position of the output shaft.
Range of ParameterUser Offset
Initial
Backward -127 127 Forward
[Option Flags (Modes)]
Reverse
Reverses the direction of rotation of the servo to signal. (Initial: OFF)
Serial
Check for serial control and remove check for PWM control. (Initial: ON)
Slave
Prevents servo from responding to the board. By setting this, communication interference is
avoided when using double servo joints with the same ID on a robot. (Initial: OFF)
Rotation
Set the servo axis to rotate like a wheel.
(Initial: OFF)
Exit