LUCIFERCatlogoGeral

> 5,000
Product references

This catalogue is a comprehensive list of Parker FCDE


products. It will help to identify appropriate valves and
coils and enable the user to generate ordering numbers.
The catalogue is intended for use by Parker Sales personnel
with the aim to select the most suitable solenoid valves
for customers.

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

PARKER FCDE

Who we are?

History
Parker FCDE has been a leading player in the
manufacturing and development of solenoid valve
technologies for over 60 years, with continuous
research and development bringing innovative
solutions to the marketplace, for example leading
the way in the utilisation of synthetic ruby for critical
water applications or the unsurpassed reliability and
precision of our pressure regulators. The expertise
accumulated and developed through the years is
evident in the superior quality of FCDE solutions.

The Fluid Control Division in Europe (FCDE) is a


division of Parker Hannin, the global leader in
motion and control technologies.
FCDE core competences are the development
and manufacturing of an extremely diverse
range of uid control products, including
solenoid valves and pressure regulators.

Where we are?

Markets

Our European headquarters are located in


Geneva, this is also where our R&D, Marketing,
Application Support and Product Management
functions are located.

Our products and solutions are typically designed


for markets including Industrial Equipment, Industrial
Automation, Mobile, Transportation, Life Sciences,
Beverage dispensing and for Fluid and Process
Control.

FCDE Products are mainly manufactured at


locations in Carouge (Geneva - Switzerland)
and Gessate (Milan - Italy).

Benets
The modular concept of our products, having
separate solenoid valves and electrical parts,
provides the customer with increased exibility by
allowing numerous combinations. This additional
exibility can enable distributors to greater reduce
valve inventory levels, whilst retaining the same
number of capabilities. Parker also has unrivalled
experience in developing customised product
solutions complying with the highest technical,
environmental, energy and service life requirements.

The
Parker
Sales
Companies
and
comprehensive distribution network support
you, wherever you are.

PARKER FCDE - GENEVA - SWITZERLAND

PARKER FCDE - MILAN - ITALY

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

GENERAL CATALOGUE FCDE


TABLE OF CONTENT
INTRODUCTION
Markets and applications ................................................................................................................................................................................. 06
A complete range of solenoid valves ......................................................................................................................................................... 08
A modular concept .............................................................................................................................................................................................. 10
ATEX Certification................................................................................................................................................................................................. 12
World class standards........................................................................................................................................................................................ 13
How to use this catalogue ............................................................................................................................................................................... 14
How to select a valve ......................................................................................................................................................................................... 16
How to order ........................................................................................................................................................................................................... 18
Coil groups............................................................................................................................................................................................................... 24

2 WAY VALVES
Valves for dry or lubricated air, neutral gases and liquids................................................................................................................ 27
Valves for water and neutral liquids ............................................................................................................................................................ 79
Anti water hammer valves..............................................................................................................................................................................113
Hot water and steam valves .........................................................................................................................................................................125
Valves for hydraulic oil and neutral liquids (up to 100 bar) ...................................................................................................................141
High corrosion resistant valves (303 Stainless Steel) ................................................................................................................................157
High corrosion resistant valves (316L Stainless Steel) ..............................................................................................................................165
Oil burner valves .................................................................................................................................................................................................177
Fast switching valves .......................................................................................................................................................................................197
Valves for beverage dispensing - Liquipure .......................................................................................................................................201

3 WAY VALVES
Valves for dry or lubricated air, neutral gases and liquids..............................................................................................................207
Valves for hydraulic oil and neutral liquids (up to 75 bar) .....................................................................................................................247
High corrosion resistant valves (303 Stainless Steel).................................................................................................................................251
Valves for beverage dispensing - Liquipure .......................................................................................................................................257

2 & 3 WAY VALVES FOR TRANSPORTATION


2 way.........................................................................................................................................................................................................................265
3 way.........................................................................................................................................................................................................................271

5 WAY DISTRIBUTORS FOR PNEUMATIC APPLICATIONS


5 way pneumatic distributors (Pipe mounting/Sub-base mounting).........................................................................................................275
4

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY PNEUMATIC DISTRIBUTORS FOR ACTUATION CONTROL


3 & 5 way pneumatic valves for actuator control (Pipe mounting) ...................................................................................................301
3 & 5 way pneumatic valves for actuator control (NAMUR)..............................................................................................................333
316L Stainless Steel 3 & 5 way valves for actuator control (Pipe mounting and NAMUR)........................................................375

EEXPRESS BUS MANIFOLD FOR ACTUATOR CONTROL


EExpress Bus Manifold for actuator control.........................................................................................................................................407

ELECTROPNEUMATIC PRESSURE REGULATORS


EPP4 Series - Basic, Comfort , Comfort ATEX Ranges .................................................................................................................411

COILS, HOUSINGS & ELECTRICAL PARTS


Introduction............................................................................................................................................................................................................443
Coils...........................................................................................................................................................................................................................453
Explosion Proof Electrical Parts..................................................................................................................................................................489
Housings .................................................................................................................................................................................................................522
Coil Accessories .................................................................................................................................................................................................526
Explosive Environments..................................................................................................................................................................................528
Coil Appendices..................................................................................................................................................................................................538

TECHNICAL INFORMATION ABOUT SOLENOID VALVES


Technical information about solenoid valves .......................................................................................................................................545

APPENDIX
Table of sub-bases for valves ......................................................................................................................................................................568
Index for Valves ...................................................................................................................................................................................................574

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

MARKETS AND APPLICATIONS

INDUSTRIAL & AUTOMATION

In order to bring customers


the best solution, Parker
offers a wide range
of products that can be divided
into specic markets:

O
O
O
O

PROCESS CONTROL
O
O
O
O
O

Compressors
Blowing
Textile
Pressure Regulation

FOOD & BEVERAGE

Valve Actuation
Oil & Gas
On & Off-Shore
Petro-Chimical
Pharmaceutical

O
O
O
O

Professional Coffee Machines


Sparkling Water
Soft Drinks
Water Dispensing

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COOLING & CLIMATE CONTROL


O
O

TRANSPORTATION

Water dispensing
Cooling systems

O
O
O
O

LIFE SCIENCE
O
O
O
O

Trucks
Trains
Bus and Coach
Marine

O
O

Military
Agriculture

HEATING SYSTEMS

Sterilizers / Autoclaves
Breathing
Water purification
Table-top equipment

O
O
O

Industrial Oil Burners


Fuel Transfer
Gas Transfer

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

A COMPLETE RANGE OF SOLENOID VALVES


FOR FLUID CONTROL

2 WAY VALVES
O
O
O
O
O
O

3 WAY VALVES

For dry or lubricated air,


neutral gases and liquids
For water and neutral liquids
Anti water hammer
Hot water and steam
For hydraulic oil and
neutral liquids (Max. 100 bar)
High corrosion
resistant

For dry or lubricated air


For hydraulic oil and
neutral liquids (Max. 75 bar)
O High corrosion resistant
O
O

(303 Stainless Steel)


O

Liquipure
for beverage
dispensing

(303 Stainless Steel)


(316L Stainless Steel)

Oil burner
O Fast switching
O Liquipure for
beverage dispensing
O

2 & 3 WAY VALVES


FOR TRANSPORTATION

5 WAY DISTRIBUTORS
FOR PNEUMATIC APPLICATIONS

2 way- direct and


piloted
O 3 way- direct
operated

Pipe mounted/ Sub-base mounting

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY PNEUMATIC


DISTRIBUTORS
FOR ACTUATION CONTROL

COILS & ELECTRICAL


PARTS
Coils
Housings
O Explosion-Proof
Electrical
Parts
O

Pipe mounted
O NAMUR interface
O 316L Stainless Steel

EEXPRESS BUS MANIFOLD


FOR ACTUATOR CONTROL

EPP4 SERIES
ELECTROPNEUMATIC
PRESSURE REGULATORS

(Pipe mounted
and with
NAMUR
interface)

ATEX zone 1/21

Basic
O Comfort
O Comfort ATEX
O

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

A MODULAR CONCEPT FOR EVERY APPLICATION


CHOOSE BETWEEN:

Actuation Modes
Direct Operated Manual Reset
Magnalift
Externally Operated
Pilot Operated
Material Types
Anodized Aluminium
Brass
303 Stainless St. Zinc Alloy
316L Stainless St. POM
Mounting Solutions
Banjo
Pipe
Sub-base
CETOP
NAMUR
ISO
Control Functions
Normally Closed Control by Electric
Impulse
Normally Open
Universal
Dual Solenoids
PWM
Internal Design
Diaphragm
Piston
Poppet
Spool
Seals
FKM
NBR
EPDM

Ruby
PUR
PCTFE
10

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

11

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

ATEX CERTIFICATION

ELECTRICAL PART ATEX CERTIFICATION


A selection of FCDE electrical parts conform to the terms
of the 94/9/EC directive and are made for potentially explosive
environments - zone 0/20, 1/21 and 2/22.
Within the coil section, the presence of the ATEX logo
shows that the coil is ATEX approved.

MECHANICAL PART ATEX CERTIFICATION


A selection of FCDE mechanical parts conform to the terms
of the 94/9/CE directive specific to non electrical equipment
for use within potentially explosive environments zones 0/20, 1/21 and 2/22.
NAMUR & piped valve ranges now include a marking which
indicates mechanical ATEX approval.
Within the valve section, the presence of the ATEX logo
shows that the valve is ATEX approved.

SOLENOID VALVE CERTIFICATION


When both the electrical and mechanical part are
ATEX approved, the solenoid valve can be used in explosive
atmospheres.
The solenoid valve will be delivered assembled and tested.

12

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

PARKER FCDE IS MEETING


WORLD CLASS STANDARDS
QUALITY STANDARDS:





O ISO 9001

O ISO 14001

O ISO TS 16949

CERTIFICATIONS AND APPROVALS:


Our products have been approved and are compliant with the relevant market requirements including:


















O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O

CE
ATEX
RoHS
UL
Reach
IECEx
CSA
Gost
SVGW
DIN
AGA
TUV
Kosha
IMQ
NSF
VDE
13

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

HOW TO USE
THIS CATALOGUE
This catalogue is a comprehensive list of Parker FCDE products. It will help to identify appropriate valves
and coils and enable the user to generate ordering numbers. The catalogue is intended for use by Parker
Sales personnel with the aim to select the most suitable solenoid valves for customers.
This catalogue is split by product family. You will find a summary page at the beginning of each valve
section. For ease of use, each valve section is divided by application.
On the first page of each Application section, you will find an overview of the products within and their
technical characteristics, to guide you to the relevant page (example below):

SECTION SUMMARY PAGE


2 WAY VALVES

Product family

VALVES FOR DRY OR LUBRICATED


AIR, NEUTRAL GASES AND LIQUIDS

Oil

Actuation

Body

Function

Direct
Operated

Brass/Pipe mounting

Normally Closed

Normally Open

Magnalift

Brass/Pipe mounting

Control by Electric Impulse


Normally Closed
Normally Open
Normally Closed

Pilot
Operated

Brass/Pipe mounting

Normally Closed

Brass/Sub-base
mounting

Normally Open

Control by Electric Impulse

Brass/Sub-base
mounting

Normally Closed
Normally Open

Water

Air

2/2

Port
Size

Orice
(mm)

Flow
Factor
Kv(l/min)

MOPD
(bar)

Max
Fluid
Temp. (C)

Page

Page

Parker
Valves

Parker
LUCIFER
Valves

1/8''
1/4''
3/8''
1/2''
1/8''
1/4''
1/4''
5 mm
5 mm
3/8''
1/2''
3/4''
1''
1/4''
3/8''
1/2''
3/4''
1''
1 1/2''
2''
1/4''
3/8''
1/2''
3/4''
1''
1 1/4''
1 1/2''
2''
1/4''
3/8''
1/2''
3/4''
1''
14 mm
14 mm

1.2 to 3
1.2 to 6
4 to 6
8.5 to 11
2.5
1.5 to 3
3 to 5
1.5 to 3
1.5
13 to 15
13 to 15
15 to 20
15 to 25
8 to 12
11 to 13
11 to 15
15 to 20
18 to 28
40
40
8
11 to 13
13 to 15
15 to 20
25 to 40
28
40
40
12
12
12
18
18
14
14

4.5
13
12
36
3.5
4
11
4.5
1.5
65
65
100
170
36
50
60
135
270
425
540
36
50
60
135
420
270
420
540
32
45
50
100
110
45
46

70
100
10
4
30
40
20
100
20
20
20
20
20
40
40
40
40
16
16
16
40
40
40
40
16
16
12
12
12
12
12
12
12
40
40

140
140
120
120
140
140
100
130
120
140
140
140
140
140
140
120
120
120
120
120
140
140
140
120
120
120
100
120
100
100
100
100
100
140
120

2
4
12
20
20
20
20
28
28
28
28
42
42
42
42
-

6
6
10
10
14
14
14
16
18
22
22
24
24
30
32
34
36
38
40
40
44
44
44
46
46
46
46
46
48
48
48
48
48
50
50

Application
Number of ways / positions
Actuation
Applicable Fluids
Actuation, body and function
Body
Mounting
Function
Technical features

Related page

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

For further technical information regarding Actuation, Body and Function, please refer to the technical
information section at the end of the catalogue.
14

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

Applicable Markets
for this valve category

Applicable Approvals
within this page

Quick selection table with


Min/Max values for all valves on the page

SECTION PRODUCT PAGE


2 WAY VALVES

2 WAY VALVES

2/2

HOT WATER AND STEAM VALVES


MAGNALIFT

For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

From

3/8''

15

65

-10

Amb Temp
(C)
-10

To

1''

15

80

10

140

50

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

Orice

BSP

mm
15

3/8''

1''

Housing
Ref.

Coil
Ref.

2995

481865

AC
W
8

481000

DC
W
-

Coil
Group

2.0

Dwg.
No.

3732

65

3.9

10

120 EPDM

221G1303

4270

2.0

3732

15

65

3.9

140 EPDM

221G1303

4270

486265

14

14

2.0

3732

15

65

3.9

140 EPDM

221G1303

2995

492425

14

14

2.0

3732

221G1330

2995

481865

2.1

3732

15

65

3.9 4500

10

10

-10

120

FKM

221G1330

492070

2.1

3732

15

65

3.9 4500

10

10

-10

120

FKM

221G1330

492190

11

2.1

3732

10

221G1503

65

3.9 4500

10

10

-10

100

FKM

2995

481865

10

221G1503

4270

481000

2.0

3732

15

65

3.9

10

140 EPDM

221G1503

4270

486265

14

14

2.0

3732

15

65

3.9

140 EPDM

221G1503

2995

492425

14

14

2.0

3732

15

80

4.8

10

100 EPDM

221G1603

2995

481865

2.0

3444

15

80

4.8

10

15

80

4.8

15

3/4''

Valve
Ref.
221G1303

Power

15

15

1/2''

Drawing 3732

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
65 3.9
0
10
0 100 EPDM

Parker LUCIFER
Valves

Flow
factors

15

65
65

3.9
3.9

0
0

100 EPDM
120 EPDM

2.0

3732

120 EPDM

221G1603

4270

481000

2.0

3444

140 EPDM

221G1603

4270

486265

14

14

2.0

3444

15

80

4.8

140 EPDM

221G1603

2995

492425

14

14

2.0

3444

15

80

4.8

10

100 EPDM

221G1703

2995

481865

2.0

15

80

4.8

10

120 EPDM

221G1703

4270

481000

2.0

3445

15

80

4.8

10

10

140 EPDM

221G1703

4270

486265

14

14

2.0

3445

15

80

4.8

10

10

140 EPDM

221G1703

2995

492425

14

14

2.0

3445

Drawing 3444

3445

Notes:
1.Valve only compatible with hydraulic oil and neutral liquids
2.Valves with model number ending in 30 or 31 are mainly equipped with electrical parts for explosion proof applications or with standard DC coils.

Drawing 3445

108

Ordering information

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

ISO
Symbol

109

A choice of Coil Groups


compatible with the selected valve.

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

Dimensional 2D* and


3D drawings

* 2D drawing shown always corresponds to the standard coil.

15

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

HOW TO SELECT
A VALVE
Once you are in the selected family

and application .

The table is designed to help you navigate to the products matching your criteria.

First decide the actuation


, then move accross the table selecting your body material
function
and technical requirements
.

After you have found products fiting within your specification, please go to the corresponding page
number in the final column
, here you will find a selection of products that match your criteria.

SELECT PRODUCT FAMILY

SELECT APPLICATION

SELECT ACTUATION

SELECT BODY

SELECT FUNCTION

SELECT TECHNICAL DATA

SELECT CORRESPONDING PAGE

16

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

VALVES FOR DRY OR LUBRICATED


AIR, NEUTRAL GASES AND LIQUIDS

Oil

Actuation
Direct
Operated

Body
Brass/Pipe mounting

Normally Open

Magnalift

Brass/Pipe mounting

Control by Electric Impulse


Normally Closed
Normally Open
Normally Closed

Pilot
Operated

Brass/Pipe mounting

Normally Closed

Brass/Sub-base
mounting

Normally Open

Control by Electric Impulse

Brass/Sub-base
mounting

Normally Closed
Normally Open

Air

2/2

Port
Size

Orice
(mm)

Flow
Factor
Kv(l/min)

MOPD
(bar)

Max
Fluid
Temp. (C)

Page

Page

Parker
Valves

Parker
LUCIFER
Valves

1/8''
1/4''
3/8''
1/2''
1/8''
1/4''
1/4''
5 mm
5 mm
3/8''
1/2''
3/4''
1''
1/4''
3/8''
1/2''
3/4''
1''
1 1/2''
2''
1/4''
3/8''
1/2''
3/4''
1''
1 1/4''
1 1/2''
2''
1/4''
3/8''
1/2''
3/4''
1''
14 mm
14 mm

1.2 to 3
1.2 to 6
4 to 6
8.5 to 11
2.5
1.5 to 3
3 to 5
1.5 to 3
1.5
13 to 15
13 to 15
15 to 20
15 to 25
8 to 12
11 to 13
11 to 15
15 to 20
18 to 28
40
40
8
11 to 13
13 to 15
15 to 20
25 to 40
28
40
40
12
12
12
18
18
14
14

4.5
13
12
36
3.5
4
11
4.5
1.5
65
65
100
170
36
50
60
135
270
425
540
36
50
60
135
420
270
420
540
32
45
50
100
110
45
46

70
100
10
4
30
40
20
100
20
20
20
20
20
40
40
40
40
16
16
16
40
40
40
40
16
16
12
12
12
12
12
12
12
40
40

140
140
120
120
140
140
100
130
120
140
140
140
140
140
140
120
120
120
120
120
140
140
140
120
120
120
100
120
100
100
100
100
100
140
120

2
4
12
20
20
20
20
28
28
28
28
42
42
42
42
-

6
6
10
10
14
14
14
16
18
22
22
24
24
30
32
34
36
38
40
40
44
44
44
46
46
46
46
46
48
48
48
48
48
50
50

Function
Normally Closed

Water

17

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

HOW TO ORDER
BETWEEN TWO PRODUCT RANGES

SELECT CORRESPO

Parker [Blue Table]


O Valves and coils have to be
2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

O Valves and coils are

BRASS
PIPE MOUNTING

delivered as separate
elements

NORMALLY CLOSED
Port Orice
size

BSP
1/8''

1/4''

mm
2.5

Flow
factors

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h m3/h bar bar bar C C
3.3 0.197 0
5
-10 140 FKM

Power

Parker Valves
Valve Order
Number

Valve
Type

Coil
Type

363380

PM146FV

ZB12

AC
W
-

4.5 0.27

-10

140

FKM

363390

PM146HV

ZB09

4.5 0.27

-10

140

FKM

363390

PM146HV

ZB12

Coil
Group

DC
W
12 20.1/20.2
-

Dwg.
No.

034

20.1/20.2

034

12 20.1/20.2

034

2.5

2.2 0.13

10

-10

140

FKM

398006 1

N74.4WV

WB4.5 230/50-60

4.5

2.5

2.2 0.13

10

-10

140

FKM

398007 1

N74.4WV

WB4.5 24/50-60

4.5

1.3

065

2.5

2.2 0.13

-10

140

FKM

398008 1

N74.4WV

WB5.0 12DC

1.3

065

2.5

2.2 0.13

-10

140

FKM

398010 1

N74.4WV

WB5.0 24DC

1.3

065

2.5

2.2 0.13

19

-10

140

FKM

398012 1

N74.4WV

WB8.0 230/50-60

1.3

065

2.5

3.3 0.197

10

-10

140

FKM

363439

PM146WV

ZB09

20.1/20.2

035

25

3 3 0 197

10

10

140

FKM

363439

PM146WV

ZB12

12 20 1/20 2

035

ordered separately
(for exceptions please check
footnotes)

1.3

O For ATEX application

please make your selection


within Parker Lucifer valves

065

O You have to order:

Valve + Coil

Order Separately

VALVE

COIL

Valve order example:

Coil order example:

363380

304002

18

CAUTION: For N74, N79, 131.4,


131, 175, 180, 161 valves series,
the valve order number indicates
assembled valve and coil for the
voltage shown.

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

NDING PAGE

Parker Lucifer [Orange Table]


O Available in quantities as

small as one piece

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
PIPE MOUNTING

BSP

Orice

mm
4

configurations

Flow
factors

Operating
Fluid
Pressure
Temp.
Differential
Min Max(MOPD) Min Max
Kv
KV
Qn
AC DC
l/min m3/h l/min bar bar bar C
C
7.5 0.45 480
0
10
4
-10 100

Parker LUCIFER
Valves

Seat
Seal

FKM

Power

Valve
Ref.

Housing
Ref.

Coil
Ref.

121K3206

2995

481865

AC
W
8

DC
W
9

Coil
Group

2.0

Dwg.
No.

3551

7.5

0.45

480

10

-10

120

FKM

121K3206

4270

481000

2.0

3551

7.5

0.45

480

10

10

-10

120

FKM

121K3206

4270

486265

14

14

2.0

3551

5
3/8''

11

0.66

750

assembled
O Available in ATEX

NORMALLY CLOSED
Port
size

O Valves and coils delivered

11

0.66

750

2.8

-10

120

FKM

121K3106

4270

481000

2.0

3551

11

0.66

750

-10

-10

120

100

FKM

FKM

121K3106

121K3106

4270

2995

486265

481865

14

14

2.0

2.0

3551

3551

12

0.72

1100

1.1

-10

100

FKM

121K3306

2995

481865

2.0/14.2

3551

12

0.72

1100

1.5

-10

120

FKM

121K3306

4270

481000

2.0/14.2

3551

12

0.72

1100

-10

120

FKM

121K3306

4270

486265

14

14

2.0/14.2

3551

85

25

15

1600

11

05

10

100

FKM

E121K46

2995

481865

20

3427

O You have to order:

Valve + Housing + Coil

One Order

VALVE
HOUSING
COIL

Valve and coil order example:

121K3206

Valve Reference

2995

Housing

481865A2

Coil and Voltage Code

19

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

HOW TO ORDER
PARKER VALVES
A PARKER SOLENOID VALVE IS COMPOSED OF 2 ELEMENTS:
The Valve

and the Coil . Both should be ordered separately.

Use the valve order


number (6 digits)
to order the valve.

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port Orice
size

BSP
1/8''

1/4''

Valve order N example:

mm
2.5

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h m3/h bar bar bar C C
3.3 0.197 0
5
-10 140 FKM

Power

Parker Valves
Valve Order
Number
363380

Valve
Type

Coil
Type

PM146FV

ZB12

AC
W
-

4.5 0.27

-10

140

FKM

363390

PM146HV

ZB09

4.5 0.27

-10

140

FKM

363390

PM146HV

ZB12

Coil
Groupp

DC
W
12 20.1/20.2
-

Dwg.
No.

034

20.1/20.2

034

12 20.1/20.2

034

2.5

2.2 0.13

10

-10

140

FKM

398006 1

N74.4WV

WB4.5 230/50-60

4.5

2.5

2.2 0.13

10

-10

140

FKM

398007 1

N74.4WV

WB4.5 24/50-60

4.5

1.3

065

2.5

2.2 0.13

-10

140

FKM

398008 1

N74.4WV

WB5.0 12DC

1.3

065

2.5

2.2 0.13

-10

140

FKM

398010 1

N74.4WV

WB5.0 24DC

1.3

065

2.5

2.2 0.13

19

-10

140

FKM

398012 1

N74.4WV

WB8.0 230/50-60

1.3

065

2.5

3.3 0.197

10

-10

140

FKM

363439

PM146WV

ZB09

20.1/20.2

035

10

363439

PM146WV

2.5

ZB12

4.5 0.27

-10

140

FKM

363444

PM146YV

ZB09

4.5 0.27

-10

140

FKM

363444

PM146YV

ZB12

4.5

363380

Flow
factors

3.3 0.197

-10

-10

140

140

FKM

FKM

363457

PM146.3KV

ZB14

1.3

12 20.1/20.2
-

065

035

20.1/20.2

035

12 20.1/20.2

035

0.527

14

4.5

0.527

2.5

-10

140

FKM

363457

PM146.3KV

ZB16

16

20.2

035

13

0.75

-10

140

FKM

363467

PM146.3ABV

ZB14

14

20.2

20.2

035

035

13

0.75

-10

140

FKM

363467

PM146.3ABV

ZB16

16

20.2

035

Notes:
1.Ordering number is for an assembled valve and coil, with the voltage shown.

20

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

HOW TO ORDER
PARKER COILS
PARKER COILS HAVE TO BE ORDERED SEPARATELY
FROM THE VALVES

Use the coil order


number (6 digits)
to order the coils

COILS
COIL GROUP

20.1
20

COILS FOR
DIN PLUG CONNECTION

ZB CO
COIL SERIES
These co
coils can be mounted with every Parker solenoid valves
corresponding to the specified Coil Group.
correspo
column "Coil Group" within valve pages.
See colum
with H class copper wire, moulded in thermoplastic
Coil manufactured
manu
material polyester with 30% glass fiber.
IP65 protection rate with EN 175301-803:2006-A. Three pin connector.
This coil conforms to the IEC/CENELEC safety standards and complies
with European low-voltage directive.
For UL recognized version: UL file MH19410.
DIN plug connector to be ordered separately (see coil accessories section).

Specication

Standard
ZB09/ZB12

Reference (without DIN plug)


Coil Group
Degree of protection
Class of insulation
Electrical connection

Elect.
Power

Ambient temperature
DC
AC

P (cold) 20C
P (cold) 20C
Attraction cold

Weight
Voltages "Un"

VAC/Hz

- 10% to + 10% of Un for AC


- 5 % to + 10 % for Un DC.

Coil order N example:

304002

UL recognized version
ZB09 for AC only
20.1

ZB09 24/50-60
ZB09 12/50-60
ZB09 230/50-60
ZB09 115/50-60
ZB09 100/50-60
ZB09 240/50-60
ZB09 48/50-60
ZB09 110-120/60
ZB09 380/50-60

IP65 according to IEC / EN 60529 standards (with DIN plug and gasket)
F 155C
The coil is connected with a 2 P + E plug according to EN 175301-803 - A
-10C to +50C
The application is limited also by the temperature range of the valve.
12 W
9W
25 VA
130 g
Order Number
VDC
Order Number
VAC/Hz
304004
304002
304012
304010
304009
304014
304008
304011
304016

ZB12 12DC
ZB12 24DC
ZB12 110DC
ZB12 48VDC

304018
304020
304022
304021

ZB09 24/60
ZB09 110-120/60
ZB09 208-240/60

Order Number
304048
304011
304051

To Order a Coil: Use 6 digits ordering number - Code Example: ZB09 24/50-60 = 304004
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

32

Important:
Valves will be delivered as separate
elements and in box quantities.

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

Coil section at the end of the catalogue

CAUTION: For ATEX applications, please refer to Parker Lucifer Valves.

21

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

HOW TO ORDER
PARKER LUCIFER SOLENOID VALVES
A PARKER LUCIFER SOLENOID VALVE IS COMPOSED OF 3 ELEMENTS:
The Valve

+ Housing + Coil .

1. Choose the valve reference


2. Choose the housing
3. Choose the coil

Choose the Valve


Reference.

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

Orice

mm
4

depending on
the protection level
(IP 44 to IP 67 found
in the coil section)

1/2''

Seat
Seal

FKM

Parker LUCIFER
Valves

Power

Valve
Ref.

Housing
Ref.

Coil
Ref.

121K3206

2995

481865

AC
W
8

DC
W
9

Coil
Group

2.0

Dwg.
No.

3551

7.5

0.45

480

10

-10

120

FKM

121K3206

4270

481000

2.0

3551

7.5

0.45

480

10

10

-10

120

FKM

121K3206

4270

486265

14

14

2.0

3551

11

0.66

750

2.8

-10

120

FKM

121K3106

4270

481000

2.0

3551

11

0.66

750

-10

120

FKM

121K3106

4270

486265

14

14

2.0

3551

 Select the housing

Operating
Fluid
Pressure
Temp.
Differential
Min Max(MOPD) Min Max
Kv
KV
Qn
AC DC
l/min m3/h l/min bar bar bar C
C
7.5 0.45 480
0
10
4
-10 100

4
5
3/8''

Flow
factors

11

12

0.66

0.72

750

1100

-10

-10

100

100

FKM

FKM

121K3106

121K3306

2995

2995

481865

481865

2.0

2.0/14.2

3551

1.1

12

0.72

1100

1.5

-10

120

FKM

121K3306

4270

481000

2.0/14.2

3551

12

0.72

1100

-10

120

FKM

121K3306

4270

486265

14

14

2.0/14.2

3551

3551

8.5

25

1.5

1600

1.1

0.5

-10

100

FKM

E121K46

2995

481865

2.0

3427

8.5

25

1.5

1600

2.2

0.5

-10

120

FKM

E121K46

4270

481000

2.0

3427

8.5

25

1.5

1600

1.2

-10

120

FKM

E121K46

4270

486265

14

14

2.0

3427

11

36

2.16

2500

0.7

0.3

-10

100

FKM

E121K45

2995

481865

2.0

3427

11

36

2.16

2500

1.2 0.35 -10

120

FKM

E121K45

4270

481000

2.0

3427

11

36

2.16

2500

2.5

120

FKM

E121K45

4270

486265

14

14

2.0

3427

0.7

-10

Notes:
1.With manual override

10

22

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

Parker Lucifer coils are available in many different voltages.


Choose the one you need by putting the voltage code at the end of your ordering number.

Choose the coil


and voltage code.

COILS
COIL GROUP

Coil Ref.

2.0/2.1

COILS FOR
DIN PLUG CONNECTION

COILS 32 mm

Voltage
Code

These coils can be mounted with every Parker solenoid valves


corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
This is an encapsulated assembly comprising a coil, integral
magnetic iron path and snap-on plug connection.
The synthetic material encapsulation provides an effective compact
housing, offering full protection against dust, oil, water, etc.
Ease of mounting in confined space - offers shock and corrosion
protection - simplifies conversion of existing equipment to other
requirements, etc.
Coils conform to the IEC/CENELEC safety standards and complies with
European low-voltage directive.
Specication

Standard
481865
482725

Ref. (without DIN plug)


Ref. (with DIN plug)
Coil Group
Degree of protection
Class of insulation
Electrical connection

2.0 / 2.1

Elect. Power

Ambient temperature

Valve and coil order example:

DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"

VAC/Hz

- 10% to + 10% of the Un

121K3206 - 2995 - 481865A2


Valve
Reference

Housing

Coil and
Voltage Code

Double frequency
483510
482635

24/50
48/50
110/50
220-230/50

IP65 according to IEC / EN 60529 standards (with DIN plug).


F 155C
The coil is connected with a 2 P + E plug according to EN 175301-803 type A
-40C to +50C
The application is limited also by the temperature range of the valve.
9W
12 W
8W
9W
26 VA (9 W)
32 VA (10 W)
130 g (without plug)
Code
VDC
Code
VAC/Hz
A2
A4
A5
3D

24
48
110

C2
C4
C5

24/50, 24/60
48/50, 48/60
110-115/50, 120/60
220-240/50, 240/60

Code
P0
S4
S5
S6

To Order a Coil choose Coil Ref + Voltage Code, example: 481865 for 24 VDC = 481865C2
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

These coils must be used with


suitable housings, see example
below:
The coil assembly kit Ref. 2995
corresponds to the "housing" of
Lucifer valve numbering system
(Valve - housing - coil - voltage).
It is composed of a nameplate
giving details of the valve type,
a round washer and a nut
to ensure the fixing between
32 mm coil and the valve.
Parker Hannin Corporation
Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

18

Important:
Valve, Housing or Coil can be ordered separately for use as a replacement or spare part.
23

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

HOW TO USE COIL GROUPS


WITHIN A VALVE PAGE
One of Parker's strengths is the modularity, adaptability and flexibility of our products.
When you select a solenoid valve, the coils displayed in the table have been chosen as they will fulfill
the majority of application requirements.

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

However, in some specific cases,


you will need special features that
will lead you to choose another coil.

BSP

3/8''

Groups have been created in order


to facilitate the selection of a compatible coil with the chosen valve.

Orice

mm
4

Operating
Fluid
Pressure
Temp.
Differential
Min Max(MOPD) Min Max
Qn
AC DC
Kv
KV
C
l/min m3/h l/min bar bar bar C
7.5 0.45 480
0
10
4
-10 100

Seat
Seal

Parker LUCIFER
Valves

Power

Valve
Ref.

Housing
Ref.

Coil
Ref.

FKM

121K3206

2995

481865

AC
W
8

DC
W
9

Coil
Group

2.0

Dwg.
No.

3551

7.5

0.45

480

10

-10

120

FKM

121K3206

4270

481000

2.0

3551

7.5

0.45

480

10

10

-10

120

FKM

121K3206

4270

486265

14

14

2.0

3551

11

0.66

750

-10

100

FKM

121K3106

2995

481865

2.0

3551

11

0.66

750

2.8

-10

120

FKM

121K3106

4270

481000

2.0

3551

11

0.66

750

-10

120

FKM

121K3106

4270

486265

14

14

2.0

3551

1.1

FKM

121K3306

2995

481865

12

0.72

1100

1.5

-10

120

FKM

121K3306

4270

481000

2.0/14.2

3551

12

0.72

1100

-10

120

FKM

121K3306

4270

486265

14

14

2.0/14.2

3551

8.5

25

1.5

1600

1.1

0.5

-10

100

FKM

E121K46

2995

481865

2.0

3427

8.5
1/2''

Flow
factors

12

25

0.72

1.5

1100

1600

2.2

0.5

-10

FKM

E121K46

4270

2.0/14.2

2.0

3551

481000

25

1.5

1600

1.2

-10

120

FKM

E121K46

4270

486265

14

14

2.0

3427

11

36

2.16

2500

0.7

0.3

-10

100

FKM

E121K45

2995

481865

2.0

3427

11

36

2.16

2500

1.2 0.35 -10

120

FKM

E121K45

4270

481000

2.0

3427

11

36

2.16

2500

2.5

120

FKM

E121K45

4270

486265

14

14

2.0

3427

-10

120

8.5

0.7

-10

100

3427

Notes:
1.With manual override

10

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

It is also possible to choose the coil rst and then select the valve using coil groups.

24

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

HOW TO USE COIL GROUPS


WITHIN A COIL PAGE
The coil section is at the end of the catalogue and displays the specifications of each coil, along with the
reference number, class of insulation, ambient temperature, electrical power and weight.

COILS
COIL GROUP

2.0/2.1

COILS FOR
DIN PLUG CONNECTION

COILS 32 mm

When refering to the coil section


you will find the coil group for
each coil. This allows you to
discover which other coils are
compatible with the valve you
have chosen.

These coils can be mounted with every Parker solenoid valves


corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
This is an encapsulated assembly comprising a coil, integral
magnetic iron path and snap-on plug connection.
The synthetic material encapsulation provides an effective compact
housing, offering full protection against dust, oil, water, etc.
Ease of mounting in confined space - offers shock and corrosion
protection - simplifies conversion of existing equipment to other
requirements, etc.
Coils conform to the IEC/CENELEC safety standards and complies with
European low-voltage directive.
Specication

Standard
481865
482725

Ref. (without DIN plug)


Ref. (with DIN plug)
Coil Group
Degree of protection
Class of insulation
Electrical connection

DC
AC

Double frequency
483510
482635
2.0 / 2.1

Ambient temperature
Elect. Power

As indicated before, the valve


121K3206 is proposed with coil
481865 but is also compatible
with the 2.0 coil group. This
means the coil 482725 is also
compatible with the chosen
valve as it is within this group.

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"

VAC/Hz

- 10% to + 10% of the Un

24/50
48/50
110/50
220-230/50

IP65 according to IEC / EN 60529 standards (with DIN plug).


F 155C
The coil is connected with a 2 P + E plug according to EN 175301-803 type A
-40C to +50C
The application is limited also by the temperature range of the valve.
9W
12 W
8W
9W
26 VA (9 W)
32 VA (10 W)
130 g (without plug)
Code
VDC
Code
VAC/Hz
A2
A4
A5
3D

24
48
110

C2
C4
C5

24/50, 24/60
48/50, 48/60
110-115/50, 120/60
220-240/50, 240/60

Code
P0
S4
S5
S6

To Order a Coil choose Coil Ref + Voltage Code, example: 481865 for 24 VDC = 481865C2
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

These coils must be used with


suitable housings, see example
below:
The coil assembly kit Ref. 2995
corresponds to the "housing" of
Lucifer valve numbering system
(Valve - housing - coil - voltage).
It is composed of a nameplate
giving details of the valve type,
a round washer and a nut
to ensure the fixing between
32 mm coil and the valve.
18

25

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

26

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

VALVES FOR DRY OR LUBRICATED


AIR, NEUTRAL GASES AND LIQUIDS

Oil

Actuation
Direct
Operated

Body
Brass/Pipe mounting

Normally Open

Magnalift

Brass/Pipe mounting

Control by Electric Impulse


Normally Closed
Normally Open
Normally Closed

Pilot
Operated

Brass/Pipe mounting

Normally Closed

Brass/Sub-base
mounting

Normally Open

Control by Electric Impulse

Brass/Sub-base
mounting

Normally Closed
Normally Open

Air

2/2

Port
Size

Orice
(mm)

Flow
Factor
Kv(l/min)

MOPD
(bar)

Max
Fluid
Temp. (C)

Page

Page

Parker
Valves

Parker
LUCIFER
Valves

1/8''
1/4''
3/8''
1/2''
1/8''
1/4''
1/4''
5 mm
5 mm
3/8''
1/2''
3/4''
1''
1/4''
3/8''
1/2''
3/4''
1''
1 1/2''
2''
1/4''
3/8''
1/2''
3/4''
1''
1 1/4''
1 1/2''
2''
1/4''
3/8''
1/2''
3/4''
1''
14 mm
14 mm

1.2 to 3
1.2 to 6
4 to 6
8.5 to 11
2.5
1.5 to 3
3 to 5
1.5 to 3
1.5
13 to 15
13 to 15
15 to 20
15 to 25
8 to 12
11 to 13
11 to 15
15 to 20
18 to 28
40
40
8
11 to 13
13 to 15
15 to 20
25 to 40
28
40
40
12
12
12
18
18
14
14

4.5
13
12
36
3.5
4
11
4.5
1.5
65
65
100
170
36
50
60
135
270
425
540
36
50
60
135
420
270
420
540
32
45
50
100
110
45
46

70
100
10
4
30
40
20
100
20
20
20
20
20
40
40
40
40
16
16
16
40
40
40
40
16
16
12
12
12
12
12
12
12
40
40

140
140
120
120
140
140
100
130
120
140
140
140
140
120
120
120
120
120
120
120
140
140
140
120
120
120
100
120
100
100
100
100
100
140
120

28
30
38
46
46
46
46
54
54
54
54
68
68
68
68
-

32
32
36
36
40
40
40
42
44
48
48
50
52
56
58
60
62
64
66
66
70
70
70
72
72
72
72
72
74
74
74
74
74
76
76

Function
Normally Closed

Water

27

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port Orice
size

BSP

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
Kv KV Qn
l/min m3/h m3/h bar bar bar C C
0.7 0.04 0
20
-10 140 FKM

Power

Parker Valves
Valve Order
Number

Valve
Type

Coil
Type

DC
W
-

Coil
Group

Dwg.
No.

398018 1

N74.4IV

WB4.5 115/50-60

AC
W
4.5

1.3

064

1.5

0.06

20

-10

140

FKM

398017 1

N74.4AV

WB4.5 115/50-60

4.5

1.3

064

1.5

0.06

20

-10

140

FKM

398014 1

N74.4AV

WB4.5 230/50-60

4.5

1.3

064

1.5

0.06

20

-10

140

FKM

398030 1

N74.4AV

WB4.5 24/50-60

4.5

1.3

064

1.5

0.06

10

-10

140

FKM

398034 1

N74.4AV

WB5.0 12DC

1.3

064

1.5

0.06

10

-10

140

FKM

398016 1

N74.4AV

WB5.0 24DC

1.3

064

1.5

0.06

10

-10

140

FKM

398013 1

N74.4AVA.5

WB5.0 5.0 24DC

1.3

064

1.5 0.09

20

-10

140

FKM

363378

PM146BV

ZB09

20.1/20.2

034

12 20.1/20.2

034

mm
1.2

1.5

1/8''

Flow
factors

1.5

1.5 0.09

18

-10

140

FKM

363378

PM146BV

ZB12

1.5 0.09

15

-10

140

FKM

398050 1

N74.4BV

WB4.5 115/50-60

4.5

1.3

064

1.5 0.09

15

-10

140

FKM

398042U 1

N74.4BV

WB4.5 115/60

4.5

1.3

064

1.5 0.09

15

-10

140

FKM

398046U 1

N74.4BV

WB4.5 208-240/60 4.5

1.3

064

1.5 0.09

15

-10

140

FKM

398038 1

N74.4BV

WB4.5 230/50-60

4.5

1.3

064

1.5 0.09

15

-10

140

FKM

398048 1

N74.4BV

WB4.5 24/50-60

4.5

1.3

064

1.5 0.09

-10

140

FKM

398029 1

N74.4BV

WB5.0 12DC

1.3

064

1.5 0.09

-10

140

FKM

398028 1

N74.4BV

WB5.0 24DC

1.3

064

2.5

2.2 0.13

10

-10

140

FKM

398026 1

N74.4FV

WB4.5 115/50-60

4.5

1.3

064

2.5

2.2 0.13

10

-10

140

FKM

398003 1

N74.4FV

WB4.5 115/60

4.5

1.3

064

2.5

2.2 0.13

10

-10

140

FKM

398000 1

N74.4FV

WB4.5 230/50-60

4.5

1.3

064

2.5

2.2 0.13

10

-10

140

FKM

398024 1

N74.4FV

WB4.5 24/50-60

4.5

1.3

064

2.5

2.2 0.13

10

-10

140

FKM

398001 1

N74.4FV

WB4.5 240/50-60

4.5

1.3

064

2.5

2.2 0.13

-10

140

FKM

398052 1

N74.4FV

WB5.0 12DC

1.3

064

2.5

2.2 0.13

-10

140

FKM

398022 1

N74.4FV

WB5.0 24DC

1.3

064

2.5

3.3 0.197

10

-10

140

FKM

363380

PM146FV

ZB09

20.1/20.2

034

Notes:
1.Ordering number is for an assembled valve and coil, with the voltage shown.

28

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

1.2

0.7

-10

-10

To

1/8''

2.5

3.3

20

140

50

Drawing 064

Drawing 034

29

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port Orice
size

Flow
factors

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h m3/h bar bar bar C C
3.3 0.197 0
5
-10 140 FKM

BSP

mm
2.5

1/8''

4.5 0.27

1/4''

Power

Parker Valves
Valve Order
Number

Valve
Type

Coil
Type

363380

PM146FV

ZB12

AC
W
-

-10

140

FKM

363390

PM146HV

ZB09

Coil
Group

DC
W
12 20.1/20.2
-

Dwg.
No.

034

20.1/20.2

034

12 20.1/20.2

034

4.5 0.27

-10

140

FKM

363390

PM146HV

ZB12

2.5

2.2 0.13

10

-10

140

FKM

398006 1

N74.4WV

WB4.5 230/50-60

4.5

1.3

065

2.5

2.2 0.13

10

-10

140

FKM

398007 1

N74.4WV

WB4.5 24/50-60

4.5

1.3

065

2.5

2.2 0.13

-10

140

FKM

398008 1

N74.4WV

WB5.0 12DC

1.3

065

2.5

2.2 0.13

-10

140

FKM

398010 1

N74.4WV

WB5.0 24DC

1.3

065

2.5

2.2 0.13

19

-10

140

FKM

398012 1

N74.4WV

WB8.0 230/50-60

1.3

065

2.5

3.3 0.197

10

-10

140

FKM

363439

PM146WV

ZB09

20.1/20.2

035

2.5

3.3 0.197

10

-10

140

FKM

363439

PM146WV

ZB12

4.5 0.27

-10

140

FKM

363444

PM146YV

ZB09

4.5 0.27

4.5

12 20.1/20.2
-

20.1/20.2

-10

140

FKM

363444

PM146YV

ZB12

-10

140

FKM

363457

PM146.3KV

ZB14

14

2.5

-10

140

FKM

363457

PM146.3KV

ZB16

16

20.2

035

-10

140

FKM

363467

PM146.3ABV

ZB14

14

20.2

035

-10

140

FKM

363467

PM146.3ABV

ZB16

16

20.2

035

0.527

4.5

0.527

13

0.75

13

0.75

12 20.1/20.2

035
035

20.2

035
035

Notes:
1.Ordering number is for an assembled valve and coil, with the voltage shown.

30

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

2.5

2.2

-10

-10

To

1/4''

13

19

140

50

Drawing 034

Drawing 065

Drawing 035

31

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

Orice

mm
1.5

1/4''

Housing
Ref.

Coil
Ref.

121M14

8993

121M14

8993

Power

Coil
Group

Dwg.
No.

3382

481180

AC
W
4

DC
W
5

1.1

488980

2.5

1.1

3382

2.0

3510
3510

0.9 0.054 70

20

-10

75

1.5

1.5 0.09

80

60

25

-30

75 PCTFE

E121K14

2995

481865

1.5

1.5 0.09

80

70

30

-30

75 PCTFE

E121K14

4270

481000

2.0

1.5

1.5 0.09

80

70

55

-30

75 PCTFE

E121K14

4270

486265

14

14

2.0

3510

0.12 125

10

-10

75

FKM

121M13

8993

481180

1.1

3382

FKM

Valve
Ref.

IS

1.5

2
1/8''

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h m3/h bar bar bar C
C
0.9 0.054 70
0
20 12 -10 75 FKM

Parker LUCIFER
Valves

Flow
factors

0.12 125

10

2.5

-10

75

FKM

121M13

8993

488980

2.5

1.1

3382

2.5

3.5 0.21 220

28

10

-30

100 Ruby

E121K23

2995

481865

2.0

3510

2.5

3.5 0.21 220

34

12

-30

130 Ruby

E121K23

4270

481000

2.0

3510

2.5

3.5 0.21 220

50

22

-30

120 Ruby

E121K23

4270

486265

14

14

2.0

3510

4.5 0.27 320

10

-10

100

FKM

121K1302

2995

481865

2.0

3510

4.5 0.27 320

10

-10

120

FKM

121K1302

4270

481000

2.0

3510

4.5 0.27 320

10

10

-10

120

FKM

121K1302

4270

486265

14

14

2.0

3510

1.2

0.85 0.051 50

80

36

-30

100 Ruby

E121K65

2995

481865

2.0

3510

1.2

0.85 0.051 50

100

43

-30

130 Ruby

E121K65

4270

481000

2.0

3510

1.2

0.85 0.051 50

100

75

-30

120 Ruby

E121K65

4270

486265

14

14

2.0

3510

1.5

1.5 0.09

80

-20

75

PUR

121K0497

2995

482740

1.6

6.0/8.0

8274

1.5

1.5 0.09

80

10

10

-20

75

PUR

121K0497

495900

2.5

6.0/8.0

8274

1.5

1.5 0.09

80

10

-20

75

PUR

121K0497

495910

6.0/8.0

8274

1.5

1.5 0.09

80

-20

75

PUR

121K0497

2995

496125

2
0.3
to 3
1.6

6.0/8.0

8274

1.5

1.5 0.09

80

60

25

-30

75 PCTFE

E121K04

2995

481865

2.0

3510

1.5

1.5 0.09

80

70

30

-30

75 PCTFE

E121K04

4270

481000

2.0

3510

1.5

1.5 0.09

80

70

55

-30

75 PCTFE

E121K04

4270

486265

14

14

2.0

3510

1.5

1.5 0.09

80

20

20

-10

100

FKM

E121K0402

2995

481865

2.0/3.0

3510

1.5

1.5 0.09

80

20

20

-10

120

FKM

E121K0402

4270

481000

2.0/3.0

3510

1.5

1.5 0.09

80

60

25

-30

100 Ruby

E121K67

2995

481865

2.0

3510

1.5

1.5 0.09

80

75

30

-30

130 Ruby

E121K67

4270

481000

2.0

3510

1.5

1.5 0.09

80

100

55

-30

120 Ruby

E121K67

4270

486265

14

14

2.0

3510

2.5

3.5 0.21 220

14

-10

100

FKM

121K0706

2995

481865

2.0

3510

2.5

3.5 0.21 220

14

-10

120

FKM

121K0706

4270

481000

2.0

3510

2.5

3.5 0.21 220

14

14

-10

120

FKM

121K0706

4270

486265

14

14

2.0

3510

2.5

3.5 0.21 220

28

10

-30

75 PCTFE

E121K07

2995

481865

2.0

3510

2.5

3.5 0.21 220

34

12

-30

75 PCTFE

E121K07

4270

481000

2.0

3510

2.5

3.5 0.21 220

50

22

-30

75 PCTFE

E121K07

4270

486265

14

14

2.0

3510

Notes:
1.Valve compatible with water up to 40C
2.With manual override

32

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

1.2

0.9

2.5

-30

-20

To

1/4''

4.5

100

130

50

Drawing 3382

Drawing 3510

Drawing 8274

33

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

1/4''

Orice

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h m3/h bar bar bar C
C
3.5 0.21 220 0
28 10 -30 100 Ruby

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.

Housing
Ref.

IS

Coil
Ref.

Power

Dwg.
No.

E121K63

2995

481865

AC
W
8

2.0

3510

2.5

3.5 0.21 220

34

12

-30

130 Ruby

E121K63

4270

481000

2.0

3510

2.5

3.5 0.21 220

50

22

-30

120 Ruby

E121K63

4270

486265

14

14

2.0

3510

3.5 0.21 250

-20

75

121K0397

2995

482740

1.6

6.0/8.0

8023

495900

2.5

8023

495910

6.0/8.0

8023

2995

496125

2
0.3
to 3
1.6

6.0/8.0

6.0/8.0

8274

mm
2.5

PUR

DC
W
9

Coil
Group

3.5 0.21 250

4.5

-20

75

PUR

121K0397

3.5 0.21 250

4.5

-20

75

PUR

121K0397

3.5 0.21 250

-20

75

PUR

121K0397

4.5 0.27 320

20

-30

75 PCTFE

E121K03

2995

481865

2.0/3.0

3510

4.5 0.27 320

25

8.5

-30

75 PCTFE

E121K03

4270

481000

2.0/3.0

3510

4.5 0.27 320

36

15

-30

75 PCTFE

E121K03

4270

486265

14

14

2.0/3.0

3510

4.5 0.27 320

10

-10

100

FKM

E121K0302

2995

481865

2.0

3510

4.5 0.27 320

10

8.5

-10

120

FKM

E121K0302

4270

481000

2.0

3510

4.5 0.27 320

10

-10

100

FKM

E121K0302

4270

486265

14

14

2.0

3510

4.5 0.27 320

10

-10

100

FKM

E121K0352

2995

481865

2.0

3510

4.5 0.27 320

10

8.5

-10

120

FKM

E121K0352

4270

481000

2.0

3510

4.5 0.27 320

10

10

-10

120

FKM

E121K0352

4270

486265

14

14

2.0

3510

4.5 0.27 320

20

-30

100 Ruby

E121K64

2995

481865

2.0

3510

4.5 0.27 320

25

8.5

-30

130 Ruby

E121K64

4270

481000

2.0

3510

4.5 0.27 320

36

15

-30

120 Ruby

E121K64

4270

486265

14

14

2.0

3510

7.5 0.45 480

10

-10

100

FKM

121K02

2995

481865

2.0

3510

7.5 0.45 480

10

-10

120

FKM

121K02

4270

481000

2.0

3510

7.5 0.45 480

10

10

-10

120

FKM

121K02

4270

486265

14

14

2.0

3510

7.5 0.45 480

10

-10

100

FKM

121K0250

2995

481865

2.0

3510

7.5 0.45 480

10

-10

120

FKM

121K0250

4270

481000

2.0

3510

7.5 0.45 480

10

10

-10

120

FKM

121K0250

4270

486265

14

14

2.0

3510

11

0.66 750

-10

100

FKM

121K01

2995

481865

2.0/14.2

3510

11

0.66 750

2.8

-10

120

FKM

121K01

4270

481000

2.0/14.2

3510

11

0.66 750

-10

120

FKM

121K01

4270

486265

14

14

2.0/14.2

3510

11

0.66 750

-10

100

FKM

121K0106

2995

481865

2.0

3510

11

0.66 750

2.8

-10

120

FKM

121K0106

4270

481000

2.0

3510

11

0.66 750

-10

120

FKM

121K0106

4270

486265

14

14

2.0

3510

11

0.66 750

-10

100

FKM

121K0150

2995

481865

2.0

3510

11

0.66 750

2.8

-10

120

FKM

121K0150

4270

481000

2.0

3510

11

0.66 750

-10

120

FKM

121K0150

4270

486265

14

14

2.0

3510

Notes:
1.Valve compatible with water up to 40C
2.With manual override

34

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

2.5

3.5

-30

-20

To

1/4''

11

50

130

50

Drawing 3510

Drawing 8023

Drawing 8274

35

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

3/8''

1/2''

Orice

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h m3/h bar bar bar C
C
7.5 0.45 480 0
10
4
-10 100 FKM

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.

Housing
Ref.

Coil
Ref.

IS

Power

Dwg.
No.

121K3206

2995

481865

AC
W
8

2.0

3551

7.5 0.45 480

10

-10

120

FKM

121K3206

4270

481000

2.0

3551

7.5 0.45 480

10

10

-10

120

FKM

121K3206

4270

486265

14

14

2.0

3551

11

0.66 750

-10

100

FKM

121K3106

2995

481865

2.0

3551

11

0.66 750

2.8

-10

120

FKM

121K3106

4270

481000

2.0

3551

11

0.66 750

-10

120

FKM

121K3106

4270

486265

14

14

2.0

3551

12

0.72 1100

1.1

-10

100

FKM

121K3306

2995

481865

2.0/14.2

3551

12

0.72 1100

1.5

-10

120

FKM

121K3306

4270

481000

2.0/14.2

3551

12

0.72 1100

-10

120

FKM

121K3306

4270

486265

14

14

2.0/14.2

3551

mm
4

DC
W
9

Coil
Group

8.5

25

1.5 1600

1.1

0.5

-10

100

FKM

E121K46

2995

481865

2.0

3427

8.5

25

1.5 1600

2.2

0.5

-10

120

FKM

E121K46

4270

481000

2.0

3427

8.5

25

1.5 1600

1.2

-10

120

FKM

E121K46

4270

486265

14

14

2.0

3427

11

36

2.16 2500

0.7

0.3

-10

100

FKM

E121K45

2995

481865

2.0

3427

11

36

2.16 2500

1.2 0.35 -10

120

FKM

E121K45

4270

481000

2.0

3427

11

36

2.16 2500

2.5

120

FKM

E121K45

4270

486265

14

14

2.0

3427

0.7

-10

Notes:
1.Valve compatible with water up to 40C
2.With manual override

36

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/8''

7.5

0.3

-10

-10

To

1/2''

11

36

10

120

50

Drawing 3551

Drawing 3427

37

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY OPEN
Port Orice
size

BSP

mm
1.5
1.5

1/4''

Flow
factors

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv
KV
Qn
AC DC
l/min m3/h m3/h bar bar bar C C
1.3 0.078
0
22
-10 140 FKM
1.3

0.078

22

-10

140

FKM

Power

Parker Valves
Valve Order
Number

Valve
Type

Coil
Type

363475

PM151GV

ZB09

AC
W
9

363475

PM151GV

ZB12

Coil
Group

Dwg.
No.

DC
W
-

20.1/20.2

036

12

20.1/20.2

036

1.8

0.11

18

-10

140

FKM

362290

PM136.2FV

ZB14

14

20.2

020

1.8

0.11

18

-10

140

FKM

362290

PM136.2FV

ZB16

16

20.2

020

2.5

0.15

12

-10

140

FKM

363570

PM151HV

ZB09

20.1/20.2

036

2.5

0.15

12

-10

140

FKM

363570

PM151HV

ZB12

12

20.1/20.2

036

0.24

5.5

-10

140

FKM

363282

PM136YV

ZB14

14

20.2

020

0.24

5.5

-10

140

FKM

363282

PM136YV

ZB16

16

20.2

020

38

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

1.5

1.3

5.5

-10

-10

To

1/4''

22

140

50

Drawing 036

Drawing 020

39

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY OPEN
Port
size

BSP
1/8''

1/4''

Orice

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV
Qn
AC DC
l/min m3/h l/min bar bar bar C
C
3.5 0.21
0
30
-30 140 Ruby

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

Coil
Group

Dwg.
No.

3510

122K9363

4270

481044

AC
W
14

2.5

3.5 0.21

30

30

-30

140 Ruby

122K9363

4270

486265

14

14

2.2

3510

1.5

1.5 0.09

9.6

30

30

-10

100 PCTFE

122K84

2995

481865

2.1

3510

mm
2.5

DC
W
-

2.2

1.5

1.5 0.09

9.6

30

30

-10

100 PCTFE

122K84

4270

481000

2.1

3510

1.5

1.5 0.09

9.6

30

30

-10

120 PCTFE

122K84

4270

486265

14

14

2.0

3510

1.5

1.5 0.09

80

20

20

-10

100

FKM

122K8406

2995

481865

2.1

3510

1.5

1.5 0.09

80

20

20

-10

120

FKM

122K8406

4270

481000

2.1

3510

1.5

1.5 0.09

80

40

40

-30

100 Ruby

122K8408

2995

481865

2.1

3510

1.5

1.5 0.09

80

40

40

-30

130 Ruby

122K8408

4270

481000

2.1

3510

1.5

1.5 0.09

80

40

40

-30

130 Ruby

122K8408

4270

486265

14

14

2.0

3510

2.5

0.18

180

12

12

-30

75 PCTFE

122K83

2995

481865

2.1

3510

2.5

0.18

180

12

12

-30

75 PCTFE

122K83

4270

481000

2.1

3510

2.5

0.18

180

12

12

-30

75 PCTFE

122K83

4270

486265

14

14

2.0

3510

2.5

0.18

180

12

12

-10

100

FKM

122K8306

2995

481865

2.0

3510

2.5

0.18

180

12

12

-10

120

FKM

122K8306

4270

481000

2.0

3510

0.18

2.5

180

12

12

-10

120

FKM

122K8306

4270

486265

14

14

2.0

3510

2.5

3.5 0.21

30

-30

140 Ruby

122K8363

4270

481044

14

2.2

3510

2.5

3.5 0.21

30

30

-30

140 Ruby

122K8363

4270

486265

14

14

2.2

3510

Coil
Group

Dwg.
No.

8296

BRASS
PIPE MOUNTING

CONTROL BY ELECTRIC IMPULSE


Port
size

Orice

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
4.5 0.27 320 0
20
-30 75 PCTFE

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.

Housing
Ref.

Coil
Ref.
484990

AC
W
11

DC
W
-

4.0

485400

13

4.0

8296

4269

484990

11

4.0

8296

4269

485400

13

4.0

8296

BSP

mm
3

125K03

4269

1/4''

4.5 0.27 320

-30

75 PCTFE

125K03

4269

11

0.66 750

-10

100

FKM

125K01

11

0.66 750

1.5

-10

100

FKM

125K01

40

Power

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

1.5

1.5

1.5

-30

-10

To

1/4''

11

40

140

50

Drawing 3510

Drawing 8296

41

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
SUB-BASE MOUNTING

NORMALLY CLOSED
Port
size

Orice

Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

Dwg.
No.

121F4417

2995

483510

2.0

3509

1.5

1.5 0.09

80

60

25

-30

100 Ruby

121F67

2995

481865

2.0

3509

1.5

1.5 0.09

80

75

30

-30

130 Ruby

121F67

4270

481000

2.0

3509

1.5

1.5 0.09

80

100

55

-30

120 Ruby

121F67

4270

486265

14

14

2.0

3509

1.5

1.5 0.09

80

60

25

-30

75 PCTFE

E121F44

2995

481865

2.0

3509

1.5

1.5 0.09

80

70

30

-30

75 PCTFE

E121F44

4270

481000

2.0

3509

1.5

1.5 0.09

80

70

55

-30

75 PCTFE

E121F44

4270

486265

14

14

2.0

3509

1.5

1.5 0.09

80

20

20

-10

100

FKM

E121F4406

2995

481865

2.0

3509

1.5

1.5 0.09

80

20

20

-10

120

FKM

E121F4406

4270

481000

2.0

3509

1.5

1.5 0.09

80

20

20

-10

120

FKM

E121F4406

4270

486265

14

14

2.0

3509

2.5

3.5 0.21 220

28

10

-30

75 PCTFE

121F47

2995

481865

2.0

3509

2.5

3.5 0.21 220

34

12

-30

75 PCTFE

121F47

4270

481000

2.0

3509

2.5

3.5 0.21 220

50

22

-30

75 PCTFE

121F47

4270

486265

14

14

2.0

3509

2.5

3.5 0.21 220

14

-10

100

FKM

121F4706

2995

481865

2.0

3509

2.5

3.5 0.21 220

14

-10

120

FKM

121F4706

4270

481000

2.0

3509

2.5

3.5 0.21 220

14

14

-10

120

FKM

121F4706

4270

486265

14

14

2.0

3509

2.5

3.5 0.21 220

28

10

-30

100 Ruby

121F63

2995

481865

2.0

3509

2.5

3.5 0.21 220

34

12

-30

130 Ruby

121F63

4270

481000

2.0

3509

2.5

3.5 0.21 220

50

22

-30

120 Ruby

121F63

4270

486265

14

14

2.0

3509

4.5 0.27 320

10

-10

100

121F4317

2995

483510

2.0

3509

4.5 0.27 320

20

-30

100 Ruby

121F64

2995

481865

2.0

3509

4.5 0.27 320

25

8.5

-30

130 Ruby

121F64

4270

481000

2.0

3509

4.5 0.27 320

36

15

-30

120 Ruby

121F64

4270

486265

14

14

2.0

3509

4.5 0.27 320

20

-30

75 PCTFE

E121F43

2995

481865

2.0

3509

4.5 0.27 320

25

8.5

-30

75 PCTFE

E121F43

4270

481000

2.0

3509

4.5 0.27 320

36

15

-30

75 PCTFE

E121F43

4270

486265

14

14

2.0

3509

4.5 0.27 320

10

-10

100

FKM

E121F4302

2995

481865

2.0/3.0

3509

4.5 0.27 320

10

8.5

-10

120

FKM

E121F4302

4270

481000

2.0/3.0

3509

4.5 0.27 320

10

10

-10

120

FKM

E121F4302

4270

486265

14

14

2.0/3.0

3509

FKM

42

DC
W
-

Coil
Group

AC
W
9

mm
1.5

SB

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
1.5 0.09 80
0
20
-10 100 EPDM

Parker LUCIFER
Valves

Flow
factors

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

5 mm

1.5

1.5

-30

-10

To

5 mm

4.5

100

130

50

Drawing 3509

43

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
SUB-BASE MOUNTING

NORMALLY OPEN
Port
size

SB

Orice

mm
1.5
1.5

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
1.5 0.09 80
0
20 20 -10 100 FKM

Parker LUCIFER
Valves

Flow
factors

1.5 0.09

80

20

20

-10

120

FKM

Valve
Ref.

Housing
Ref.

Coil
Ref.

122F44

2995

122F44

4270

44

Power

Coil
Group

Dwg.
No.

481865

AC
W
8

DC
W
9

2.1

3509

481000

2.1

3509

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

5 mm

1.5

1.5

20

-10

-10

To

5 mm

1.5

1.5

20

120

50

Drawing 3509

45

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
MAGNALIFT

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port Orice
size

Flow
factors

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
Kv KV Qn
l/min m3/h m3/h bar bar bar C C
40 2.4
0
5
-10 140 FKM

Power

Parker Valves
Valve Order
Number

Valve
Type

Coil
Type

Dwg.
No.

3/8''

mm
13

361810

PM123IV

ZB09

AC
W
9

20.1

004

1/2''

13

40

2.4

-10

140

FKM

361850

PM123AV

ZB09

20.1

003

3/4''

20

100

-10

140

FKM

361910

PM123CV

JB14

14

21.0

005

1''

25

117

-10

140

FKM

361950

PM123DV

JB14

14

21.0

006

BSP

46

DC
W
-

Coil
Group

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/8''

13

40

-10

-10

To

1''

25

117

140

50

Drawing 004

Drawing 003

Drawing 005

Drawing 006

47

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
MAGNALIFT

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

3/8''

1/2''

Orice

Flow
factors
Qn
l/min
4500

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

Dwg.
No.

221G13

2995

481865

2.0

3732

NBR

221G13

4270

481000

2.0

3732

100

NBR

221G13

4270

486265

14

14

2.0

3732

100

FKM

221G23

2995

481865

2.0

3732

120

FKM

221G23

4270

481000

2.0

3732

140

FKM

221G23

4270

486265

14

14

2.0

3732

10

-10

100

FKM

221G2330

12

2995

481865

2.1

3732

10

10

-10

100

FKM

221G2330

12

492070

2.1

3732

10

10

-10

100

FKM

221G2330

12

492190

11

2.1

3732

4500

16

-10

100

NBR

221G15

2995

481865

2.0

3732

3.9

4500

16

-10

100

NBR

221G15

4270

481000

2.0

3732

3.9

4500

16

-10

100

NBR

221G15

4270

486265

14

14

2.0

3732

65

3.9

4500

10

-10

100

FKM

221G1530

2995

481865

2.1

3732

15

65

3.9

4500

10

10

-10

120

FKM

221G1530

492070

2.1

3732

15

65

3.9

4500

10

10

-10

120

FKM

221G1530

492190

11

2.1

3732

15

65

3.9

4500

16

100

FKM

221G25

2995

481865

2.0

3732

15

65

3.9

4500

16

120

FKM

221G25

4270

481000

2.0

3732

15

65

3.9

4500

20

140

FKM

221G25

4270

486265

14

14

2.0

3732

15

65

3.9

4500

10

-10

100

FKM

221G2530

12

2995

481865

2.1

3732

15

65

3.9

4500

10

10

-10

100

FKM

221G2530

12

492070

2.1

3732

15

65

3.9

4500

10

10

-10

100

FKM

221G2530

12

492190

11

2.1

3732

15

65

3.9

4500

16

-10

15

65

3.9

4500

16

16

-10

15

65

3.9

4500

16

15

65

3.9

4500

16

15

65

3.9

4500

20

15

65

3.9

4500

15

65

3.9

4500

15

65

3.9

4500

15

65

3.9

15

65

15

65

15

100

DC
W
-

Coil
Group

AC
W
8

mm
15

Kv KV
l/min m3/h
65 3.9

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
bar bar bar C
C
0
16
-10 100 NBR

Notes:
1.Valve only compatible with hydraulic oil and air/neutral gases
2.Valves with model number ending in 30 or 31 are mainly equipped with electrical parts for explosion proof applications or with standard DC coils.
3.With 4 position selector for controlled closure rate

48

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/8''

15

65

-10

-10

To

1/2''

15

65

20

140

50

Drawing 3732

49

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
MAGNALIFT

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

3/4''

Orice

Flow
factors
Qn
l/min
6000

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

DC
W
-

Coil
Group

Dwg.
No.

221G16

2995

481865

AC
W
8

2.0

3444

15

80

4.8

6000

16

-10

100

FKM

221G16

4270

481000

2.0

3444

15

80

4.8

6000

-10

100

FKM

221G16

4270

486265

14

14

2.0

3444

15

80

4.8

6000

16

-10

100

NBR

221G1610

2995

481865

2.0

3444

15

80

4.8

6000

16

-10

100

NBR

221G1610

4270

481000

2.0

3444

15

80

4.8

6000

16

-10

100

NBR

221G1610

4270

486265

14

14

2.0

3444

15

80

4.8

6000

10

10

-10

100

FKM

221G1630

2995

481865

2.1

3444

15

80

4.8

6000

10

10

-25

40

FKM

221G1630

492070

2.1

3444

15

80

4.8

6000

10

10

-25

40

FKM

221G1630

492190

11

2.1

3444

15

80

4.8

6000

10

10

-10

100

FKM

221G1631

23

2995

481865

2.1

3444

15

80

4.8

6000

10

10

-25

40

FKM

221G1631

23

492070

2.1

3444

15

80

4.8

6000

10

10

-25

40

FKM

221G1631

23

15

80

4.8

6000

16

100

FKM

221G26

15

80

4.8

6000

16

120

FKM

221G26

15

80

4.8

6000

20

140

FKM

221G26

15

80

4.8

6000

10

-10

100

FKM

221G2630

mm
15

Kv KV
l/min m3/h
80 4.8

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
bar bar bar C
C
0
16
-10 100 FKM

492190

11

2.1

3444

2995

481865

2.0

3444

4270

481000

2.0

3444

4270

486265

14

14

2.0

3444

12

2995

481865

2.1

3444

15

80

4.8

6000

10

10

-25

40

FKM

221G2630

12

492070

2.1

3444

15

80

4.8

6000

10

10

-25

40

FKM

221G2630

12

492190

11

2.1

3444

Notes:
1.Valve only compatible with hydraulic oil and air/neutral gases
2.Valves with model number ending in 30 or 31 are mainly equipped with electrical parts for explosion proof applications or with standard DC coils.
3.With 4 position selector for controlled closure rate

50

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/4''

15

80

-25

-10

To

3/4''

15

80

20

140

50

Drawing 3444

51

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
MAGNALIFT

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

1''

Orice

Flow
factors
Kv KV
l/min m3/h
80 4.8

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

DC
W
-

Coil
Group

Dwg.
No.

221G17

2995

481865

AC
W
8

2.0

3445

15

80

4.8

6000

16

-10

100

NBR

221G17

4270

481000

2.0

3445

15

80

4.8

6000

16

-10

100

NBR

221G17

4270

486265

14

14

2.0

3445

15

80

4.8

6000

16

-10

100

NBR

221G1710

2995

481865

2.0

3445

15

80

4.8

6000

16

-10

100

NBR

221G1710

4270

481000

2.0

3445

15

80

4.8

6000

16

-10

100

NBR

221G1710

4270

486265

14

14

2.0

3445

15

80

4.8

6000

10

10

-10

100

FKM

221G1730

12

2995

481865

2.1

3445

15

80

4.8

6000

10

10

-10

120

FKM

221G1730

12

492070

2.1

3445

15

80

4.8

6000

10

10

-10

120

FKM

221G1730

12

492190

11

2.1

3445

15

80

4.8

6000

16

100

FKM

221G27

2995

481865

2.0

3445

15

80

4.8

6000

16

120

FKM

221G27

4270

481000

2.0

3445

15

80

4.8

6000

20

120

FKM

221G27

4270

486265

14

14

2.0

3445

15

80

4.8

6000

10

100

FKM

221G2730

12

2995

481865

2.1

3445

15

80

4.8

6000

10

10

-10

65

FKM

221G2730

12

492070

2.1

3445

15

80

4.8

6000

10

10

-10

75

FKM

221G2730

12

492190

11

2.1

3445

25

170 10.2

14000

16

-10

100

NBR

221G21

2995

481865

2.0

3448

25

170 10.2

14000

16

-10

100

NBR

221G21

4270

481000

2.0

3448

25

170 10.2

14000

16

-10

100

NBR

221G21

4270

486265

14

14

2.0

3448

25

160

9.6

14000

16

100

FKM

221G2106

2995

481865

2.0

3448

25

160

9.6

14000

16

120

FKM

221G2106

4270

481000

2.0

3448

25

160

9.6

14000

16

120

FKM

221G2106

4270

486265

14

14

2.0

3448

25

160

9.6

14000

16

-10

100

NBR

221G2110

2995

481865

2.0

3448

25

160

9.6

14000

16

-10

100

NBR

221G2110

4270

481000

2.0

3448

25

160

9.6

14000

16

-10

100

NBR

221G2110

4270

486265

14

14

2.0

3448

25

170 10.2

14000

10

-10

100

FKM

221G2130

12

2995

481865

2.1

3448

25

170 10.2

14000

10

10

-25

40

FKM

221G2130

12

492070

2.1

3448

25

170 10.2

14000

10

10

-25

40

FKM

221G2130

12

492190

11

2.1

3448

25

170 10.2

14000

10

100

FKM

221G2136

2995

481865

2.0

3448

25

170 10.2

14000

10

100

FKM

221G2136

4270

481000

2.0

3448

mm
15

Qn
l/min
6000

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
bar bar bar C
C
0
16
-10 100 NBR

Notes:
1.Valve only compatible with hydraulic oil and air/neutral gases
2.Valves with model number ending in 30 or 31 are mainly equipped with electrical parts for explosion proof applications or with standard DC coils.
3.With 4 position selector for controlled closure rate

52

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1''

15

80

-25

-10

To

1''

25

170

20

120

50

Drawing 3445

Drawing 3448

53

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port Orice
size

Flow
factors

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
Kv KV Qn
l/min m3/h m3/h bar bar bar C C
33
2
0.5 16
-10 90 NBR

Coil
Type

366501 1

PM168.1IN

ZB09

-10

90

NBR

366501 1

PM168.1IN

ZB12

15

-10

90

NBR

366770

PM173IN

WB4.5

4.5

1.3

12

-10

90

NBR

366770

PM173IN

WB5.0

1.3

054

16

-10

90

NBR

366511 1

PM168.1AN

ZB09

20.1/20.2

046
046

3/8''

13

33

0.5

13

50

0.35

13

50

0.35

13

42

2.5

0.5

1''

Valve
Type

Dwg.
No.

16

mm
13

3/4''

Valve Order
Number

Coil
Group

AC
W
9

BSP

1/2''

Power

Parker Valves

DC
W
-

20.1/20.2

048

12

20.1/20.2

048
054

13

42

2.5

0.5

16

-10

90

NBR

366511 1

PM168.1AN

ZB12

12

20.1/20.2

13

58

3.5

0.35

15

-10

90

NBR

366775

PM173AN

WB4.5

4.5

1.3

053

13

58

3.5

0.35

12

-10

90

NBR

366775

PM173AN

WB5.0

1.3

053

20

117

0.5

16

-10

90

NBR

366521 1

PM168.1CN

ZB09

20.1/20.2

046

20

117

0.5

16

-10

90

NBR

366521 1

PM168.1CN

ZB12

12

20.1/20.2

046

25

133

0.5

16

-10

90

NBR

366531 1

PM168.1DN

ZB09

20.1/20.2

047

25

133

0.5

-10

90

NBR

366531 1

PM168.1DN

ZB12

12

20.1/20.2

047

Notes:
1.Valve only compatible with air and neutral gases

54

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/8''

13

33

-10

-10

To

1''

25

133

16

90

50

Drawing 048

Drawing 054

Drawing 046

Drawing 053

Drawing 047

55

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

1/4''

Orice

Flow
factors
Qn
m3/h
1600

E321H11

Valve
Ref.

Housing
Ref.

Coil
Ref.

IS

Power

DC
W
9

Coil
Group

Dwg.
No.

124

2995

481865

AC
W
8

2.0

3523

36

2.16

1600

0.3

40

30

-10

100

NBR

E321H11

124

4270

481000

2.0

3523

36

2.16

1600

0.3

40

40

-10

100

NBR

E321H11

124

4270

486265

14

14

2.0

3523

11

28

1.68

1800

0.2

10

-10

100

FKM

E321K10

2995

481865

2.0

3429

11

28

1.68

1800

0.2

10

-10

100

FKM

E321K10

4270

481000

2.0

3429

12

30

1.8

2150

0.3

10

10

-10

100

FKM

321K31

8993

481180

1.1

7093

12

30

1.8

2150

0.3

10

-10

75

FKM

321K31

8993

488980

2.5

1.1

7093

12

30

1.8

2150

0.3

10

10

-10

100

FKM

321K3106

8993

481180

1.1

7093

12

30

1.8

2150

0.3

10

-10

75

FKM

321K3106

8993

488980

2.5

1.1

7093

12

32

1.92

2150

0.3

12

12

-10

100

FKM

321K4156

2995

481865

2.1/3.0

7094

12

32

1.92

2150

0.3

12

12

-10

120

FKM

321K4156

4270

481000

2.1/3.0

7094

mm
8

Kv KV
l/min m3/h
36 2.16

Parker LUCIFER
Valves

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
bar bar bar C
C
0.3 40 25 -10 100 NBR

Notes:
1.Minimum pressure differential = 0.3 bar for opening and 0 bar for closing
2.Pilot seat disc in synthetic Ruby
3.Valve only compatible with air and neutral gases
4.With 4 position selector for controlled closure rate

Drawing 7094

56

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

28

-10

-10

To

1/4''

12

36

40

120

50

Drawing 3523

Drawing 3429

Drawing 7093

57

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

3/8''

Orice

Flow
factors
Kv KV
l/min m3/h
50
3

Parker LUCIFER
Valves

Qn
m3/h
2800

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
bar bar bar C
C
0.3 40 25 -10 100 NBR

E321H13

Valve
Ref.

Housing
Ref.

Coil
Ref.

IS

Power

Dwg.
No.

124

2995

481865

AC
W
8

2.0

3521

11

50

2800

0.3

40

30

-10

100

NBR

E321H13

124

4270

481000

2.0

3521

11

50

2800

0.3

40

40

-10

100

NBR

E321H13

124

4270

486265

14

14

2.0

3521

11

36

2.16

2500

0.2

10

-10

100

FKM

E321K13

4270

481000

2.0

3429

11

36

2.16

2500

0.2

10

10

-10

100

FKM

E321K13

4270

486265

2.0

3429

36

2.16

2500

0.2

10

-10

100

NBR

E321K1314

2995

483466

2.0

3429

11

36

2.16

2500

0.2

10

10

-10

100

NBR

E321K1314

4270

486265

14
8 to
11
14

14

11

14

2.0

3429

12

45

2.7

3050

0.3

10

10

-10

100

FKM

321K33

8993

481180

1.1

7093

12

45

2.7

3050

0.3

10

-10

75

FKM

321K33

8993

488980

2.5

1.1

7093

12

45

2.7

3050

0.3

10

10

-10

100

FKM

321K3306

8993

481180

1.1

7093

12

45

2.7

3050

0.3

10

-10

75

FKM

321K3306

8993

488980

2.5

1.1

7093

12

45

2.7

3050

0.3

12

12

-10

100

FKM

321K4356

2995

481865

2.1/3.0

7094

12

45

2.7

3050

0.3

12

12

-10

120

FKM

321K4356

4270

481000

2.1/3.0

7094

mm
11

DC
W
9

Coil
Group

Notes:
1.Minimum pressure differential = 0.3 bar for opening and 0 bar for closing
2.Pilot seat disc in synthetic Ruby
3.Valve only compatible with air and neutral gases
4.With 4 position selector for controlled closure rate

Drawing 7094

58

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/8''

11

36

-10

-10

To

3/8''

12

50

40

120

50

Drawing 3521

Drawing 3429

Drawing 7093

59

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

1/2''

Orice

Flow
factors
Kv KV
l/min m3/h
36 2.16

Qn
m3/h
2500

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
bar bar bar C
C
0.2 10
3
-10 100 NBR

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

IS

Power

Coil
Group

Dwg.
No.

3427

E321K15

2995

481865

AC
W
8

11

36

2.16

2500

0.2

10

10

-10

120

NBR

E321K15

4270

486265

14

14

2.0

3427

11

36

2.16

2500

0.2

10

-10

100

FKM

E321K1514

2995

481865

2.0

3427

11

36

2.16

2500

0.2

10

-10

120

FKM

E321K1514

483371

2.0

3427

11

36

2.16

2500

0.2

10

-10

100

NBR

E321K25

2995

481865

2.0

3427

11

36

2.16

2500

0.2

10

-10

120

NBR

E321K25

492070

2.0

3427

12

50

3400

0.3

10

10

-10

100

NBR

321K35

8993

481180

1.1

7093

12

50

3400

0.3

10

-10

75

NBR

321K35

8993

488980

2.5

1.1

7093

12

50

3400

0.3

10

10

-10

100

FKM

321K3506

8993

481180

1.1

7093

12

50

3400

0.3

10

-10

75

FKM

321K3506

8993

488980

15

60

3.6

3150

0.3

10

-10

100

NBR

321H1590

2995

483580.01 *

15

60

3.6

3150

0.3

10

-10

100

NBR

321H1590

488660.01 *

15

60

3.6

3150

0.3

10

-10

100

NBR

321H1590

495910

15

3150

1.5

40

40

-10

50

PUR

321H35

23

2995

481865

2.5
0.5
to 3
0.3
to 3
0.3
to 3
9

15

3150

1.5

40

40

-10

50

PUR

321H35

23

4270

481000

15

60

3.6

3150

0.3

40

25

-10

100

NBR

E321H15

124

2995

481865

15

60

3.6

3150

0.3

40

30

-10

100

NBR

E321H15

124

4270

481000

15

60

3.6

3150

0.3

40

40

-10

100

NBR

E321H15

124

4270

486265

mm
11

DC
W
9

2.0

1.1

7093

7.0/8.0

3978

7.0/8.0

3978

7.0/8.0

3978

2.1

3522

2.1

3522

2.0

3522

2.0

3522

14

14

2.0

3522

Notes:
1.Minimum pressure differential = 0.3 bar for opening and 0 bar for closing
2.Pilot seat disc in synthetic Ruby
3.Valve only compatible with air and neutral gases
4.With 4 position selector for controlled closure rate

Drawing 3522

60

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/2''

11

-10

-10

To

1/2''

15

60

40

120

50

Drawing 3427

Drawing 7093

Drawing 3978

61

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

3/4''

Orice

mm
15

Flow
factors
Kv KV
l/min m3/h
-

Parker LUCIFER
Valves

Qn
m3/h
3550

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
bar bar bar C
C
1.5 40 40 -10 50 PUR

321H36

Valve
Ref.

Housing
Ref.

Coil
Ref.

23

2995

23

4270

IS

Power

Coil
Group

Dwg.
No.

481865

AC
W
8

DC
W
9

2.1

3696

481000

2.1

3696
7097

15

3550

1.5

40

40

-10

50

PUR

321H36

18

100

9400

0.3

10

10

-10

100

NBR

321K36

8993

481180

1.1

18

100

9400

0.3

10

-10

75

NBR

321K36

8993

488980

2.5

1.1

7097

18

100

9400

0.3

10

10

-10

100

FKM

321K3606

8993

481180

1.1

7097

18

100

9400

0.3

10

-10

75

FKM

321K3606

8993

488980

2.5

1.1

7097

20

135

8.1

9500

0.3

16

16

-10

100

NBR

E321G36

2995

481865

2.0

3442

20

135

8.1

9500

0.3

16

16

-10

100

NBR

E321G36

4270

481000

2.0

3442

20

135

8.1

9500

0.3

16

16

-10

100

FKM

E321G3606

2995

481865

2.0/14.1

3442

20

135

8.1

9500

0.3

16

16

-10

120

FKM

E321G3606

4270

481000

2.0/14.1

3442

20

135

8.1

9500

0.3

16

16

-10

120

FKM

E321G3606

4270

486265

14

14

2.0/14.1

3442

Notes:
1.Minimum pressure differential = 0.3 bar for opening and 0 bar for closing
2.Pilot seat disc in synthetic Ruby
3.Valve only compatible with air and neutral gases
4.With 4 position selector for controlled closure rate

62

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/4''

15

-10

-10

To

3/4''

20

135

40

120

50

Drawing 3696

Drawing 7097

Drawing 3442

63

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

1''

Orice

Flow
factors

mm
18

Kv KV
l/min m3/h
110 6.6

Qn
m3/h
10150

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
bar bar bar C
C
0.3 10 10 -10 100 NBR

18

110

6.6

10150

0.3

10

-10

75

NBR

18

110

6.6

10150

0.3

10

10

-10

100

18

110

6.6

10150

0.3

10

-10

25

185 11.1

14100

0.3

10

-10

25

185 11.1

14100

0.3

10

-10

Parker LUCIFER
Valves
Valve
Ref.

IS

Power

Housing
Ref.

Coil
Ref.

321K37

8993

321K37

8993

FKM

321K3706

8993

75

FKM

321K3706

8993

75

FKM

321G3790

2995

483580.01 *

75

FKM

321G3790

488660.01 *

Coil
Group

Dwg.
No.

7098

481180

AC
W
4

DC
W
5

1.1

488980

2.5

1.1

7098

481180

1.1

7098

488980

25

185 11.1

14100

0.3

10

-10

75

FKM

321G3790

495910

25

180 10.8

14000

0.3

16

16

-10

100

NBR

E321G37

2995

481865

2.5
0.5
to 3
0.3
to 3
0.3
to 3
9

25

180 10.8

14000

0.3

16

16

-10

100

NBR

E321G37

4270

481000

2.0

3442

25

180 10.8

14000

0.3

16

16

-10

100

FKM

E321G3706

2995

481865

2.0/14.1

3442

25

180 10.8

14000

0.3

16

16

-10

120

FKM

E321G3706

4270

481000

2.0/14.1

3442

25

180 10.8

14000

0.3

16

16

-10

120

FKM

E321G3706

4270

486265

14

14

2.0/14.1

3442

28

270 16.2

18000

0.3

16

16

-10

100

NBR

E321G38

2995

481865

2.0

3442

28

270 16.2

18000

0.3

16

16

-10

100

NBR

E321G38

4270

481000

2.0

3442

28

270 16.2

18000

0.3

16

16

-10

100

FKM

E321G3806

2995

481865

2.0

3442

28

270 16.2

18000

0.3

16

16

-10

120

FKM

E321G3806

4270

481000

2.0

3442

28

270 16.2

18000

0.3

16

16

-10

100

FKM

E321G3806

4270

486265

14

14

2.0

3442

1.1

7098

7.0

3442

7.0

3442

7.0

3442

2.0

3442

Notes:
1.Minimum pressure differential = 0.3 bar for opening and 0 bar for closing
2.Pilot seat disc in synthetic Ruby
3.Valve only compatible with air and neutral gases
4.With 4 position selector for controlled closure rate

64

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1''

18

110

-10

-10

To

1''

28

270

16

120

50

Drawing 7098

Drawing 3442

65

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

1 1/2''

2''

Orice

Flow
factors

mm

Kv KV
l/min m3/h

Qn
m3/h

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
bar bar bar C
C

40

425 25.5

31500

0.5

Parker LUCIFER
Valves

IS

Valve
Ref.

Housing
Ref.

Coil
Ref.

321G3990

2995

483580.01 *
488660.01 *

Power

40

425 25.5

31500

0.5

10

-10

75

NBR

321G3990

40

425 25.5

31500

0.5

10

-10

75

NBR

321G3990

495910

40

420 25.2

31500

0.3

16

-10

100

NBR

E321G39

2995

481865

DC
W
0.5
to 3
0.3
to 3
0.3
to 3
9

40

420 25.2

31500

0.3

16

8.5

-10

100

NBR

E321G39

4270

481000

40

420 25.2

31500

0.3

16

-10

100

FKM

E321G3906

2995

481865

40

420 25.2

31500

0.3

16

8.5

-10

120

FKM

E321G3906

4270

481000

40

420 25.2

31500

0.3

16

16

-10

100

FKM

E321G3906

4270

486265

40

540 32.4

38100

0.5

10

-10

75

FKM

321G4090

2995

483580.01 *

40

540 32.4

38100

0.5

10

-10

75

FKM

321G4090

488660.01 *

40

540 32.4

38100

0.5

10

-10

75

FKM

321G4090

495910

40

540 32.4

40000

0.3

16

-10

100

NBR

E321G40

2995

481865

40

540 32.4

40000

0.3

16

8.5

-10

100

NBR

E321G40

4270

40

540 32.4

40000

0.3

16

-10

100

FKM

E321G4006

40

540 32.4

40000

0.3

16

8.5

-10

120

FKM

40

540 32.4

40000

0.3

16

-10

120

FKM

10

-10

75

NBR

AC
W
-

Coil
Group

Dwg.
No.

7.0

8113

7.0

8113

7.0

8113

2.0

3442

2.0

3442

2.0

3442

2.0

3442

14

2.0

3442

7.0

8113

7.0

8113

7.0

8113

14
0.5
to 3
0.3
to 3
0.3
to 3
9

2.0

3442

481000

2.0

3442

2995

481865

2.0

3442

E321G4006

4270

481000

2.0

3442

E321G4006

4270

486265

14

14

2.0

3442

Notes:
1.Minimum pressure differential = 0.3 bar for opening and 0 bar for closing
2.Pilot seat disc in synthetic Ruby
3.Valve only compatible with air and neutral gases
4.With 4 position selector for controlled closure rate

66

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1 1/2''

40

420

-10

-10

To

2''

40

540

16

120

50

Drawing 8113

Drawing 3442

67

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY OPEN
Port Orice
size

BSP
3/8''
1/2''
3/4''
1''

Flow
factors

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h m3/h bar bar bar C C
33
2
0.5
16 -10 90 NBR

Power

Parker Valves
Valve Order
Number

Valve
Type

Coil
Type

Dwg.
No.

366601 1

PM169.1IN

ZB16

AC
W
-

20.1/20.2

052

13

33

0.5

16

-10

90

NBR

366601 1

PM169.1IN

ZH14

20.1/20.2

052

13

42

2.5

0.5

16

-10

90

NBR

366606 1

PM169.1AN

ZB16

12

20.1/20.2

049

13

42

2.5

0.5

16

-10

90

NBR

366606 1

PM169.1AN

ZH14

20.1/20.2

049

20

117

0.5

16

-10

90

NBR

366611 1

PM169.1CN

ZB16

12

20.1/20.2

050

20

117

0.5

16

-10

90

NBR

366611 1

PM169.1CN

ZH14

20.1/20.2

050

25

133

0.5

16

-10

90

NBR

366616 1

PM169.1DN

ZB16

12

20.1/20.2

051

25

133

0.5

16

-10

90

NBR

366616 1

PM169.1DN

ZH14

20.1/20.2

051

mm
13

DC
W
12

Coil
Group

Notes:
1.Valve only compatible with air and neutral gases

Drawing 051

68

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/8''

13

33

16

-10

-10

To

1''

25

133

16

90

50

Drawing 052

Drawing 049

Drawing 050

69

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY OPEN
Port
size

BSP

1/4''

3/8''

1/2''

Orice

Flow
factors
Qn
l/min
1600

322H71

Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

DC
W
9

Coil
Group

Dwg.
No.

13

2995

481865

AC
W
8

2.0

3523

36

2.16

1600

0.3

40

30

-10

100

NBR

322H71

13

4270

481000

2.0

3523

36

2.16

1600

0.3

40

40

-10

100

NBR

322H71

13

4270

486265

14

14

2.0

3523

36

2.16

0.3

40

40

-10

100

FKM

322H7106

13

2995

481865

2.0/14.1

3523

36

2.16

0.3

40

40

-10

120

FKM

322H7106

13

4270

481000

2.0/14.1

3523

36

2.16

0.3

40

40

-10

140

FKM

322H7106

13

4270

486265

14

14

2.0/14.1

3523

11

50

3240

0.3

40

40

-10

75

NBR

322H73

13

2995

481865

2.0

3523

11

50

3240

0.3

40

40

-10

75

NBR

322H73

13

4270

481000

2.0

3523

11

50

3240

0.3

40

40

-10

75

NBR

322H73

13

4270

486265

14

14

2.0

3523

11

50

0.3

40

40

-10

100

FKM

322H7306

13

2995

481865

2.0/14.1

3523

11

50

0.3

40

40

-10

100

FKM

322H7306

13

4270

481000

2.0/14.1

3523

11

50

0.3

40

40

-10

140

FKM

322H7306

13

4270

486265

14

14

2.0/14.1

3523

mm
8

Kv KV
l/min m3/h
36 2.16

Parker LUCIFER
Valves

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
bar bar bar C
C
0.3 40 25 -10 100 NBR

15

60

3.6

3890

0.3

15

15

-10

100

NBR

322G75

2995

481865

2.1

3522

15

60

3.6

3890

0.3

15

15

-10

100

NBR

322G75

4270

481000

2.1

3522

15

60

3.6

3890

0.3

20

20

-10

100

FKM

322G7506

2995

481865

2.0

3522

15

60

3.6

3890

0.3

20

20

-10

100

FKM

322G7506

4270

481000

2.0

3522

15

60

3.6

3890

0.3

20

20

-10

100

FKM

322G7506

4270

486265

14

14

2.0

3522

15

3150

1.5

40

40

-10

50

PUR

322H35

2995

481865

2.1

7569

15

3150

1.5

40

40

-10

50

PUR

322H35

4270

481000

2.1

7569

15

60

3.6

3890

0.3

40

40

-10

100

NBR

322H75

13

2995

481865

2.0

3522

15

60

3.6

3890

0.3

40

40

-10

100

NBR

322H75

13

4270

481000

2.0

3522

15

60

3.6

3890

0.3

40

40

-10

100

NBR

322H75

13

4270

486265

14

14

2.0

3522

15

60

3.6

0.3

40

40

-10

100

FKM

322H7506

13

2995

481865

2.0/14.1

3522

15

60

3.6

0.3

40

40

-10

120

FKM

322H7506

13

4270

481000

2.0/14.1

3522

15

60

3.6

0.3

40

40

-10

140

FKM

322H7506

13

4270

486265

14

14

2.0/14.1

3522

Notes:
1.Minimum pressure differential = 0.3 bar for opening and 0 bar for closing
2.Minimum pressure differential = 1.5 bar for opening and 0.3 bar for closing
3.Pilot seat disc in synthetic Ruby
4.Valve only compatible with air and neutral gases

70

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

15

-10

-10

To

1/2''

15

60

40

140

50

Drawing 3523

Drawing 3522

Drawing 7569

71

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY OPEN
Port
size

BSP

3/4''

1''

1 1/4''
1 1/2''

2''

Orice

mm
15

Flow
factors
Kv KV
l/min m3/h
-

Parker LUCIFER
Valves

Qn
l/min
3550

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
bar bar bar C
C
1.5 40 40 -10 50 PUR

322H36

Valve
Ref.

Housing
Ref.

Coil
Ref.

24

2995

24

4270

Power

Coil
Group

Dwg.
No.

481865

AC
W
8

DC
W
9

2.1

7570

481000

2.1

7570

15

3550

1.5

40

40

-10

50

PUR

322H36

20

135

8.1

9500

0.3

16

16

-10

100

NBR

322G36

2995

481865

2.1

3442

20

135

8.1

9500

0.3

16

16

-10

100

NBR

322G36

4270

481000

2.1

3442

20

135

8.1

9500

0.3

16

16

-10

100

FKM

322G3606

2995

481865

2.1

3442

20

135

8.1

9500

0.3

16

16

-10

120

FKM

322G3606

4270

481000

2.1

3442

25

180 10.8 14000

0.3

16

16

-10

100

NBR

322G37

2995

481865

2.1

3442

25

180 10.8 14000

0.3

16

16

-10

100

NBR

322G37

4270

481000

2.1

3442

25

180 10.8 14000

0.3

16

16

-10

100

FKM

322G3706

2995

481865

2.1

3442

25

180 10.8 14000

0.3

16

16

-10

120

FKM

322G3706

4270

481000

2.1

3442

28

270 16.2 18000

0.3

16

16

-10

100

NBR

322G38

2995

481865

2.1

3442

28

270 16.2 18000

0.3

16

16

-10

100

NBR

322G38

4270

481000

2.1

3442

40

420 25.2 31500

0.3

12

12

-10

100

FKM

322G3906

2995

481865

2.1

3442

40

420 25.2 31500

0.3

12

12

-10

100

FKM

322G3906

4270

481000

2.1

3442

28

270 16.2 18000

0.3

16

16

-10

100

FKM

322G3806

2995

481865

2.1

3442

28

270 16.2 18000

0.3

16

16

-10

120

FKM

322G3806

4270

481000

2.1

3442

40

420 25.2 31500

0.3

12

12

-10

100

NBR

322G39

2995

481865

2.1

3442

40

420 25.2 31500

0.3

12

12

-10

100

NBR

322G39

4270

481000

2.1

3442

40

540 32.4 40000

0.3

12

12

-10

100

NBR

322G40

2995

481865

2.1

3442

40

540 32.4 40000

0.3

12

12

-10

100

NBR

322G40

4270

481000

2.1

3442

40

540 32.4 40000

0.3

12

12

-10

100

FKM

322G4006

2995

481865

2.1

3442

40

540 32.4 40000

0.3

12

12

-10

120

FKM

322G4006

4270

481000

2.1

3442

Notes:
1.Minimum pressure differential = 0.3 bar for opening and 0 bar for closing
2.Minimum pressure differential = 1.5 bar for opening and 0.3 bar for closing
3.Pilot seat disc in synthetic Ruby
4.Valve only compatible with air and neutral gases

72

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/4''

15

12

-10

-10

To

2''

40

540

40

120

50

Drawing 7570

Drawing 3442

73

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
PILOT OPERATED

BRASS
PIPE MOUNTING

CONTROL BY ELECTRIC IMPULSE


Port
size

BSP
1/4''
3/8''
1/2''
3/4''
1''

Orice

mm
12
12

Flow
factors
Kv KV
l/min m3/h
32 1.92
32

1.92

Parker LUCIFER
Valves

Qn
l/min
2150

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
bar bar bar C
C
0.3 12
-10 100 FKM

Valve
Ref.

Housing
Ref.

Coil
Ref.

325K4106

4269

2150

0.3

325K4106

4269

12

-10

100

FKM

Power

Coil
Group

Dwg.
No.

484990

AC
W
11

DC
W
-

4.0

7094

485400

13

4.0

7094

12

45

2.7

3050

0.3

12

-10

100

FKM

325K4306

4269

484990

11

4.0

7094

12

45

2.7

3050

0.3

12

-10

100

FKM

325K4306

4269

485400

13

4.0

7094

12

50

3400

0.3

12

-10

100

FKM

325K4506

4269

484990

11

4.0

7094

12

50

3400

0.3

12

-10

100

FKM

325K4506

4269

485400

13

4.0

7094

18

100

9400

0.3

12

-10

100

FKM

325K4606

4269

484990

11

4.0

7099

18

100

9400

0.3

12

-10

100

FKM

325K4606

4269

485400

13

4.0

7099

18

110

6.6

10150

0.3

12

-10

100

FKM

325K4706

4269

484990

11

4.0

7100

18

110

6.6

10150

0.3

12

-10

100

FKM

325K4706

4269

485400

13

4.0

7100

74

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

12

32

12

-10

-10

To

1''

18

110

12

100

50

Drawing 7094

Drawing 7099

Drawing 7100

75

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
PILOT OPERATED

BRASS
SUB-BASE MOUNTING

NORMALLY CLOSED
Port
size

SB

Orice

Flow
factors

mm
14

Kv KV
Qn
l/min m3/h l/min
2100

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
bar bar bar C
C
1.5 40 40 -10 50 PUR

Parker LUCIFER
Valves
Valve
Ref.

Power

Housing
Ref.

Coil
Ref.

Coil
Group

Dwg.
No.

3520

321F35

2995

481865

AC
W
8

DC
W
9

14

2100

1.5

40

40

-10

50

PUR

321F35

2995

492425

14

14

2.0
2.0

3520

14

2100

13

13

-10

50

PUR

421F35

2995

481865

2.1

3520

14

45

2.7

2100

0.3

40

25

-10

100

NBR

E321F32

2995

481865

2.0

3520

14

45

2.7

2100

0.3

40

30

-10

100

NBR

E321F32

4270

481000

2.0

3520

14

45

2.7

2100

0.3

40

40

-10

100

NBR

E321F32

4270

486265

14

14

2.0

3520

14

45

2.7

0.3

40

25

-10

100

FKM

E321F3202

1234

2995

481865

2.0

3520

14

45

2.7

0.3

40

30

-10

120

FKM

E321F3202

1234

4270

481000

2.0

3520

14

45

2.7

0.3

40

40

-10

140

FKM

E321F3202

1234

4270

486265

14

14

2.0

3520

Coil
Group

Dwg.
No.

Notes:
1.Minimum pressure differential = 0.3 bar for opening and 0 bar for closing
2.Pilot seat disc in synthetic Ruby
3.Valve only compatible with hydraulic oil and neutral liquids
4.With 4 position selector for controlled closure rate

BRASS
SUB-BASE MOUNTING

NORMALLY OPEN
Port
size

SB

Orice

Flow
factors

mm
14

Qn
Kv KV
l/min m3/h l/min
2100

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
bar bar bar C
C
1.5 40 40 -10 50 PUR

Parker LUCIFER
Valves
Valve
Ref.

Power

Housing
Ref.

Coil
Ref.

322F35

2995

481865

AC
W
8

DC
W
9

2.1

7527

14

46

2.76

0.3

40

40

-10

75

NBR

322F72

124

2995

481865

2.1

3520

14

46

2.76

0.3

40

40

-10

75

NBR

322F72

124

4270

481000

2.1

3520

14

45

2.7

0.3

40

40

100

FKM

322F7206

1234

2995

481865

2.1/14.1

3520

14

45

2.7

0.3

40

40

120

FKM

322F7206

1234

4270

481000

2.1/14.1

3520

Notes:
1.Minimum pressure differential = 0.3 bar for opening and 0 bar for closing
2.Pilot seat disc in synthetic Ruby
3.Valve only compatible with hydraulic oil and neutral liquids
4.With 4 position selector for controlled closure rate

76

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

14 mm

14

13

-10

-10

To

14 mm

14

46

40

140

50

Drawing 3520

Drawing 7527

77

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

78

Parker Hannin Corporation


Fluid Control Division Europe
Geneva - Switzerland
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

VALVES FOR WATER AND NEUTRAL


LIQUIDS

Water

Actuation
Direct
Operated

Body
Brass/Pipe mounting

Brass/Sub-base
mounting

Pilot
Operated

Brass/Pipe mounting

Normally Open
Control by Electric Impulse
Normally Closed
Normally Closed

Normally Open

Brass/Sub-base
mounting

Port
Size

Orice
(mm)

Flow
Factor
Kv(l/min)

MOPD
(bar)

Max
Fluid
Temp. (C)

Page

Page

Parker
Valves

Parker
LUCIFER
Valves

1/8''
1/4''
3/8''
1/2''
1/4''
1/4''
SB
5 mm
1/4''
3/8''
1/2''
3/4''
1''
1 1/4''
1 1/2''
2''
1/4''
3/8''
1/2''
3/4''
1''
1 1/4''
1 1/2''
2''
2 1/2''
3''

1.5 to 3
1.5 to 6
4 to 6
8.5 to 11
2.5
5
2 to 2.5
1.5 to 3
11 to 12
11 to 13
11 to 13
18 to 20
18 to 28
35
40
40 to 50
12
12 to 13
12 to 15
18 to 20
18 to 25
35
40
50
65
75

4.5
13
12
36
3
11
3
4.5
32
50
50
140
270
420
500
620
32
50
60
140
180
420
500
620
1100
1334

20
20
10
4
12
5
15
20
12
20
20
20
20
10
16
16
12
20
20
20
20
10
12
10
10
10

140
140
120
120
120
100
140
120
120
140
140
140
140
140
140
140
120
140
140
140
140
140
140
140
90
90

80
82
90
94
94
94
94
96
96
96
106
106
106
106
106
106
106
106
106

84
84
86
86
86
88
92
98
98
100
102
104
104
104
108
108
108
108
110
110
-

14 mm

14

45

40

100

110

Function
Normally Closed

Normally Closed

2/2

79

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR WATER AND NEUTRAL LIQUIDS


DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port Orice
size

BSP

mm
1.5
1.5

1/8''

Flow
factors

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
Kv KV Qn
l/min m3/h m3/h bar bar bar C C
1.5 0.09 0
20
-10 140 FKM
1.5 0.09

Power

Parker Valves
Valve Order
Number

Valve
Type

Coil
Type

DC
W
-

Coil
Group

Dwg.
No.

363378

PM146BV

ZB09

AC
W
9

20.1/20.2

034

18

-10

140

FKM

363378

PM146BV

ZB12

12

20.1/20.2

034

2.2

0.12

10

-10

140

FKM

392349 12

161.4AV

KT09 115/50

22.0

043

2.2

0.12

10

-10

140

FKM

392355 12

161.4AV

KT09 230/50

22.0

043

2.2

0.12

10

-10

140

FKM

392335 12

161.4AV

KT09 24/50

22.0

043

2.2

0.12

10

-10

140

FKM

392366 12

161.4AV

KT09 240/50

22.0

043

2.2

0.12

-10

140

FKM

392372 12

161.4AV

KT10 12 DC

10

22.0

043

0.12

-10

140

FKM

392370 12

161.4AV

KT10 24 DC

10

22.0

043

2.5

3.3 0.197

10

-10

140

FKM

363380

PM146FV

ZB09

20.1/20.2

034

2.5

3.3 0.197

-10

140

FKM

363380

PM146FV

ZB12

12

20.1/20.2

034

2.8

2.9 0.174

-10

140

FKM

392389 12

161.4BV

KT09 115/60

22.0

043

2.8

2.9 0.174

-10

140

FKM

392388 12

161.4BV

KT09 230/50

22.0

043

4.5 0.27

-10

140

FKM

363390

PM146HV

ZB09

20.1/20.2

034

4.5 0.27

-10

140

FKM

363390

PM146HV

ZB12

12

20.1/20.2

034

2.2

Notes:
1.Maximum pressure for steam: 4 Bar (140C)
2.Ordering number is for an assembled valve and coil, with the voltage shown.

80

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

1.5

1.5

-10

-10

To

1/8''

4.5

20

140

50

Drawing 034

Drawing 043

81

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR WATER AND NEUTRAL LIQUIDS


DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port Orice
size

BSP

1/4''

Flow
factors

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h m3/h bar bar bar C C
2 0.12 0
10
-10 140 FKM

Power

Parker Valves
Valve Order
Number

Valve
Type

Coil
Type

Dwg.
No.

392408 12

161.4EV

KT09 115/50

AC
W
9

22.0

044

2.2

0.12

10

-10

140

FKM

392408 12

161.4EV

KT09 115/60

22.0

044

2.2

0.12

10

-10

140

FKM

392409 12

161.4EV

KT09 208-230/60

22.0

044

2.2

0.12

10

-10

140

FKM

392395 12

161.4EV

KT09 230/50

22.0

044

2.2

0.12

10

-10

140

FKM

392173 12

161.4EV

KT09 24/50

22.0

044

2.2

0.12

10

-10

140

FKM

392396 12

161.4EV

KT09 240/50

22.0

044

2.2

0.12

-10

140

FKM

392170 12

161.4EV

KT10 12V DC

10

22.0

044

mm
2.2

DC
W
-

Coil
Group

0.12

-10

140

FKM

392169 12

161.4EV

KT10 24 DC

10

22.0

044

2.5

3.3 0.197

10

-10

140

FKM

363439

PM146WV

ZB09

20.1/20.2

035

2.5

3.3 0.197

10

-10

140

FKM

363439

PM146WV

ZB12

12

20.1/20.2

035

4.5 0.27

-10

140

FKM

363444

PM146YV

ZB09

20.1/20.2

035

4.5 0.27

-10

140

FKM

363444

PM146YV

ZB12

12

20.1/20.2

035

2.2

4.5

0.527

-10

140

FKM

363457

PM146.3KV

ZB14

14

20.2

035

4.5

0.527

2.5

-10

140

FKM

363457

PM146.3KV

ZB16

16

20.2

035

13

0.75

-10

140

FKM

363467

PM146.3ABV

ZB14

14

20.2

035

13

0.75

-10

140

FKM

363467

PM146.3ABV

ZB16

16

20.2

035

Notes:
1.Maximum pressure for steam: 4 Bar (140C)
2.Ordering number is for an assembled valve and coil, with the voltage shown.

82

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

2.2

-10

-10

To

1/4''

13

10

140

50

Drawing 044

Drawing 035

83

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR WATER AND NEUTRAL LIQUIDS


DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

Orice

BSP

mm
1.5

1/8''

1.5

1/4''

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
0.9 0.054 70
0
20 12 -10 75 FKM

Parker LUCIFER
Valves

Flow
factors

0.9 0.054 70

Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

DC
W
5

Coil
Group

Dwg.
No.

121M14

8993

481180

AC
W
4

1.1

3382

20

-10

75

FKM

121M14

8993

488980

2.5

1.1

3382
3382

0.12 125

10

-10

75

FKM

121M13

8993

481180

1.1

0.12 125

10

2.5

-10

75

FKM

121M13

8993

488980

2.5

1.1

3382

2995

481865

2.0/3.0

3510

1.5

1.5 0.09

80

20

20

-10

100

FKM

E121K0402

1.5

1.5 0.09

80

20

20

-10

120

FKM

E121K0402

4270

481000

2.0/3.0

3510

2.5

3.5 0.21 220

14

-10

100

FKM

121K0706

2995

481865

2.0

3510

2.5

3.5 0.21 220

14

-10

120

FKM

121K0706

4270

481000

2.0

3510

2.5

3.5 0.21 220

14

14

-10

120

FKM

121K0706

4270

486265

14

14

2.0

3510

4.5 0.27 320

10

-10

100

FKM

E121K0302

2995

481865

2.0

3510

4.5 0.27 320

10

8.5

-10

120

FKM

E121K0302

4270

481000

2.0

3510

4.5 0.27 320

10

-10

100

FKM

E121K0302

4270

486265

14

14

2.0

3510

4.5 0.27 320

10

-10

100

FKM

E121K0352

2995

481865

2.0

3510

4.5 0.27 320

10

8.5

-10

120

FKM

E121K0352

4270

481000

2.0

3510

4.5 0.27 320

10

10

-10

120

FKM

E121K0352

4270

486265

14

14

2.0

3510

7.5 0.45 480

10

-10

100

FKM

121K02

2995

481865

2.0

3510

7.5 0.45 480

10

-10

120

FKM

121K02

4270

481000

2.0

3510

7.5 0.45 480

10

10

-10

120

FKM

121K02

4270

486265

14

14

2.0

3510

7.5 0.45 480

10

-10

100

FKM

121K0250

2995

481865

2.0

3510

7.5 0.45 480

10

-10

120

FKM

121K0250

4270

481000

2.0

3510

7.5 0.45 480

10

10

-10

120

FKM

121K0250

4270

486265

14

14

2.0

3510

11

0.66 750

-10

100

FKM

121K01

2995

481865

2.0/14.2

3510

11

0.66 750

2.8

-10

120

FKM

121K01

4270

481000

2.0/14.2

3510

11

0.66 750

-10

120

FKM

121K01

4270

486265

14

14

2.0/14.2

3510

11

0.66 750

-10

100

FKM

121K0106

2995

481865

2.0

3510

11

0.66 750

2.8

-10

120

FKM

121K0106

4270

481000

2.0

3510

11

0.66 750

-10

120

FKM

121K0106

4270

486265

14

14

2.0

3510

11

0.66 750

-10

100

FKM

121K0150

2995

481865

2.0

3510

11

0.66 750

2.8

-10

120

FKM

121K0150

4270

481000

2.0

3510

11

0.66 750

-10

120

FKM

121K0150

4270

486265

14

14

2.0

3510

Notes:
1.With manual override

84

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

1.5

0.9

-10

-10

To

1/4''

11

20

120

50

Drawing 3382

Drawing 3510

85

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR WATER AND NEUTRAL LIQUIDS


DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

3/8''

1/2''

Orice

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
7.5 0.45 480 0
10
4
-10 100 FKM

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

Dwg.
No.

121K3206

2995

481865

AC
W
8

2.0

3551

7.5 0.45 480

10

-10

120

FKM

121K3206

4270

481000

2.0

3551

7.5 0.45 480

10

10

-10

120

FKM

121K3206

4270

486265

14

14

2.0

3551

11

0.66 750

-10

100

FKM

121K3106

2995

481865

2.0

3551

11

0.66 750

2.8

-10

120

FKM

121K3106

4270

481000

2.0

3551

11

0.66 750

-10

120

FKM

121K3106

4270

486265

14

14

2.0

3551

12

0.72 1100

1.1

-10

100

FKM

121K3306

2995

481865

2.0/14.2

3551

12

0.72 1100

1.5

-10

120

FKM

121K3306

4270

481000

2.0/14.2

3551

12

0.72 1100

-10

120

FKM

121K3306

4270

486265

14

14

2.0/14.2

3551

mm
4

DC
W
9

Coil
Group

8.5

25

1.5 1600

1.1

0.5

-10

100

FKM

E121K46

2995

481865

2.0

3427

8.5

25

1.5 1600

2.2

0.5

-10

120

FKM

E121K46

4270

481000

2.0

3427

8.5

25

1.5 1600

1.2

-10

120

FKM

E121K46

4270

486265

14

14

2.0

3427

11

36

2.16 2500

0.7

0.3

-10

100

FKM

E121K45

2995

481865

2.0

3427

11

36

2.16 2500

1.2 0.35 -10

120

FKM

E121K45

4270

481000

2.0

3427

11

36

2.16 2500

2.5

120

FKM

E121K45

4270

486265

14

14

2.0

3427

Coil
Group

Dwg.
No.

0.7

-10

Notes:
1.With manual override

BRASS
PIPE MOUNTING

NORMALLY OPEN
Port
size

Orice

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
3 0.18 180 0
12 12 -10 100 FKM

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.

Housing
Ref.

Coil
Ref.

BSP

mm
2.5

122K8306

2995

1/4''

2.5

0.18 180

12

12

-10

120

FKM

122K8306

4270

2.5

0.18 180

12

12

-10

120

FKM

122K8306

4270

86

Power

481865

AC
W
8

DC
W
9

2.0

3510

481000

2.0

3510

486265

14

14

2.0

3510

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

2.5

0.3

-10

-10

To

1/2''

11

36

12

120

50

Drawing 3551

Drawing 3427

Drawing 3510

87

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR WATER AND NEUTRAL LIQUIDS


DIRECT OPERATED

BRASS
PIPE MOUNTING

CONTROL BY ELECTRIC IMPULSE


Port
size

BSP
1/4''

Orice

mm
5
5

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
11 0.66 750 0
5
-10 100 FKM

Parker LUCIFER
Valves

Flow
factors

11

0.66 750

1.5

-10

100

FKM

Valve
Ref.

Housing
Ref.

Coil
Ref.

125K01

4269

125K01

4269

88

Power

Coil
Group

Dwg.
No.

484990

AC
W
11

DC
W
-

4.0

8296

485400

13

4.0

8296

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

11

1.5

-10

-10

To

1/4''

11

100

50

Drawing 8296

89

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR WATER AND NEUTRAL LIQUIDS


DIRECT OPERATED

BRASS
SUB-BASE MOUNTING

NORMALLY CLOSED
Port Orice
size

SB

mm
2
2.5

Flow
factors

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h m3/h bar bar bar C C
2 0.12 0
15
-10 140 FKM
3

0.18

10

-10

140

FKM

Power

Parker Valves
Valve Order
Number

Valve
Type

Coil
Type

360469

PM125BV

397146J

PM125CV.2

90

Coil
Group

Dwg.
No.

ZB09

AC
W
9

DC
W
-

20.1/20.2

007

ZB09

20.1/20.2

007

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

SB

10

-10

-10

To

SB

2.5

15

140

50

Drawing 007

91

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR WATER AND NEUTRAL LIQUIDS


DIRECT OPERATED

BRASS
SUB-BASE MOUNTING

NORMALLY CLOSED
Port
size

Orice

Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

Dwg.
No.

E121F4406

2995

481865

2.0

3509

1.5

1.5 0.09

80

20

20

-10

120

FKM

E121F4406

4270

481000

2.0

3509

1.5

1.5 0.09

80

20

20

-10

120

FKM

E121F4406

4270

486265

14

14

2.0

3509

4.5 0.27 320

10

-10

100

FKM

E121F4302

2995

481865

2.0/3.0

3509

4.5 0.27 320

10

8.5

-10

120

FKM

E121F4302

4270

481000

2.0/3.0

3509

4.5 0.27 320

10

10

-10

120

FKM

E121F4302

4270

486265

14

14

2.0/3.0

3509

92

DC
W
9

Coil
Group

AC
W
8

mm
1.5

SB

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
1.5 0.09 80
0
20 20 -10 100 FKM

Parker LUCIFER
Valves

Flow
factors

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

5 mm

1.5

1.5

-10

-10

To

5 mm

4.5

20

120

50

Drawing 3509

93

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR WATER AND NEUTRAL LIQUIDS


PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port Orice
size

Flow
factors

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Valve Order
Min Max(MOPD) Min Max
Number
Kv KV Qn
AC DC
l/min m3/h m3/h bar bar bar C C
50
3
0.1 10 10 -10 140 EPDM 443778W 1

Valve
Type

Coil
Type
481865

2.0

028

481865

2.0

028

7321BIN01

481865

2.0

028

444492W

7321BIV00

481865

2.0

028

140 EPDM

443781W 1

7321BAH00

481865

2.0

028

-10

90

NBR

443779W

7321BAN00

481865

2.0

028

20

-10

90

NBR

443780W 2

7321BAN01

481865

2.0

028

FKM

7321BIH00

3/8''

13

50

0.1

20

20

-10

90

NBR

443776W

7321BIN00

13

50

0.1

20

20

-10

90

NBR

443777W 2

13

50

0.1

20

20

-10

140

FKM

13

50

0.1

10

10

-10

13

50

0.1

20

20

13

50

0.1

20

1''

Dwg.
No.

DC
W
9

mm
13

3/4''

Coil
Group

AC
W
8

BSP

1/2''

Power

Parker Valves

13

50

0.1

20

20

-10

140

444494W

7321BAV00

481865

2.0

028

20

140

8.4

0.1

10

10

-10

140 EPDM

443785W 1

7321BCH00

481865

2.0

057

20

140

8.4

0.1

20

20

-10

90

NBR

443782W

7321BCN00

481865

2.0

057

20

140

8.4

0.1

10

10

-10

90

NBR

443783W 2

7321BCN01

481865

2.0

057

20

140

8.4

0.1

20

20

-10

140

FKM

444497W

7321BCV00

481865

2.0

057

25

160

9.6

0.1

10

10

-10

140 EPDM

443789W 1

7321BDH00

481865

2.0

057

25

160

9.6

0.1

20

20

-10

90

NBR

443786W

7321BDN00

481865

2.0

057

25

160

9.6

0.1

10

10

-10

90

NBR

443787W 2

7321BDN01

481865

2.0

057

25

160

9.6

0.1

20

20

-10

140

FKM

443804W

7321BDV00

481865

2.0

057

Notes:
1.Maximum pressure for steam: 4 Bar (140C)
2.With manual override

94

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/8''

13

50

10

-10

-10

To

1''

25

160

20

140

50

Drawing 028

Drawing 057

95

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR WATER AND NEUTRAL LIQUIDS


PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port Orice
size

Flow
factors

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Valve Order
Min Max(MOPD) Min Max
Number
Kv KV Qn
AC DC
l/min m3/h m3/h bar bar bar C C
420 25.2 0.1 10 10 -10 140 EPDM 443793W 1

Valve
Type

Coil
Type

Dwg.
No.

058

481865

DC
W
9

2.0

481865

2.0

058

7321BEN01

481865

2.0

058

443797W 1

7321BFH00

481865

2.0

058

443794W

7321BFN00

481865

2.0

058

443795W 2

7321BFN01

481865

2.0

058

140 EPDM

443801W 1

7321BGH00

481865

2.0

058

-10

90

NBR

443798W

7321BGN00

481865

2.0

058

-10

90

NBR

443799W 2

7321BGN01

481865

2.0

058

mm
35

7321BEH00

1 1/4''

35

420 25.2

0.1

10

10

-10

90

NBR

443790W

7321BEN00

35

420 25.2

0.1

-10

90

NBR

443791W 2

40

500

30

0.1

10

10

-10

140 EPDM

40

500

30

0.1

10

10

-10

90

NBR

40

500

30

0.1

-10

90

NBR

50

620 37.2

0.1

10

10

-10

50

620 37.2

0.1

10

10

50

620 37.2

0.1

2''

Coil
Group

AC
W
8

BSP

1 1/2''

Power

Parker Valves

Notes:
1.Maximum pressure for steam: 4 Bar (140C)
2.With manual override

96

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1 1/4''

35

420

-10

-10

To

2''

50

620

10

140

50

Drawing 058

97

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR WATER AND NEUTRAL LIQUIDS


PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

1/4''

3/8''

Orice

Flow
factors
Qn
l/min
1800

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

DC
W
9

Coil
Group

Dwg.
No.

E321K10

2995

481865

AC
W
8

2.0

3429

11

28

1.68

1800

0.2

10

-10

100

FKM

E321K10

4270

481000

2.0

3429

12

30

1.8

2150

0.3

10

10

-10

100

FKM

321K31

8993

481180

1.1

7093

12

30

1.8

2150

0.3

10

-10

75

FKM

321K31

8993

488980

2.5

1.1

7093

12

32

1.92

2150

0.3

12

12

-10

100

NBR

321K4106

2995

481865

2.1/3.0

7094

mm
11

Kv KV
l/min m3/h
28 1.68

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
bar bar bar C
C
0.2 10
3
-10 100 FKM

12

32

1.92

2150

0.3

12

12

-10

120

NBR

321K4106

4270

481000

2.1/3.0

7094

11

36

2.16

2500

0.2

10

-10

100

FKM

E321K13

4270

481000

2.0

3429

11

36

2.16

2500

0.2

10

10

-10

100

FKM

E321K13

4270

486265

14

2.0

3429

11

36

2.16

2500

0.2

10

-10

100

NBR

E321K1314

2995

483466

2.0

3429

11

36

2.16

2500

0.2

10

10

-10

100

NBR

E321K1314

4270

486265

14
8 to
11
14

14

2.0

3429

12

45

2.7

3050

0.3

10

10

-10

100

FKM

321K33

8993

481180

1.1

7093

12

45

2.7

3050

0.3

10

-10

75

FKM

321K33

8993

488980

2.5

1.1

7093

12

45

2.7

3050

0.3

12

12

-10

100

FKM

321K4306

2995

481865

2.1/3.0

7094

12

45

2.7

3050

0.3

12

12

-10

120

FKM

321K4306

4270

481000

2.1/3.0

7094

Notes:
1.Pilot seat disc in synthetic Ruby
2.With manual override

98

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

11

28

-10

-10

To

3/8''

12

45

12

120

50

Drawing 3429

Drawing 7093

Drawing 7094

99

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR WATER AND NEUTRAL LIQUIDS


PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

1/2''

Orice

Flow
factors
Qn
l/min
2500

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

Coil
Group

Dwg.
No.

3427

E321K15

2995

481865

AC
W
8

11

36

2.16

2500

0.2

10

10

-10

120

NBR

E321K15

4270

486265

14

14

2.0

3427

11

36

2.16

2500

0.2

10

-10

100

FKM

E321K1514

2995

481865

2.0

3427

11

36

2.16

2500

0.2

10

-10

120

FKM

E321K1514

483371

2.0

3427

11

36

2.16

2500

0.2

10

-10

100

NBR

E321K25

2995

481865

2.0

3427

11

36

2.16

2500

0.2

10

-10

120

NBR

E321K25

492070

2.0

3427

12

50

3400

0.3

10

10

-10

100

NBR

321K35

8993

481180

1.1

7093

12

50

3400

0.3

10

-10

75

NBR

321K35

8993

488980

2.5

1.1

7093

12

50

3400

0.3

12

12

-10

100

FKM

321K4506

2995

481865

2.1/3.0

7094

12

50

3400

0.3

12

12

-10

120

FKM

321K4506

4270

481000

2.1/3.0

7094

12

50

3400

0.3

12

12

-10

100

FKM

321K4556

2995

481865

2.1/3.0

7094

12

50

3400

0.3

12

12

-10

120

FKM

321K4556

4270

481000

2.1/3.0

7094

mm
11

Kv KV
l/min m3/h
36 2.16

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
bar bar bar C
C
0.2 10
3
-10 100 NBR

DC
W
9

2.0

Notes:
1.Pilot seat disc in synthetic Ruby
2.With manual override

100

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/2''

11

36

-10

-10

To

1/2''

12

50

12

120

50

Drawing 3427

Drawing 7093

Drawing 7094

101

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR WATER AND NEUTRAL LIQUIDS


PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

3/4''

Orice

Kv KV
l/min m3/h
100 6

Qn
l/min
9400

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
bar bar bar C
C
0.3 10 10 -10 100 NBR

18

100

9400

0.3

10

-10

75

NBR

18

100

9400

0.3

12

12

-10

100

18

100

9400

0.3

12

12

-10

18

100

9400

0.3

12

12

-10

18

100

9400

0.3

12

12

20

135

8.1

9500

0.3

16

16

20

135

8.1

9500

0.3

16

16

mm
18

Flow
factors

Parker LUCIFER
Valves
Valve
Ref.

Power

Housing
Ref.

Coil
Ref.

321K36

8993

321K36

8993

FKM

321K4606

2995

120

FKM

321K4606

100

FKM

321K4656

-10

120

FKM

321K4656

4270

481000

-10

100

NBR

E321G36

2995

481865

-10

100

NBR

E321G36

4270

481000

Coil
Group

Dwg.
No.

7097

481180

AC
W
4

DC
W
5

1.1

488980

2.5

1.1

7097

481865

2.1/3.0

7099

4270

481000

2.1/3.0

7099

2995

481865

2.1/3.0

7099

2.1/3.0

7099

2.0

3442

2.0

3442

Notes:
1.Pilot seat disc in synthetic Ruby
2.With manual override

102

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/4''

18

100

-10

-10

To

3/4''

20

135

16

120

50

Drawing 7097

Drawing 7099

Drawing 3442

103

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR WATER AND NEUTRAL LIQUIDS


PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

1''

1 1/2''
2''

Orice

Flow
factors
Kv KV
Qn
l/min m3/h l/min
110 6.6 10150

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
bar bar bar C
C
0.3 10 10 -10 100 NBR

mm
18
18

110

6.6

10150

0.3

10

-10

75

NBR

18

110

6.6

10150

0.3

12

12

-10

100

18

110

6.6

10150

0.3

12

12

-10

18

110

6.6

10150

0.3

12

12

-10

18

110

6.6

10150

0.3

12

12

25

180 10.8 14000

0.3

16

16

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

321K37

8993

321K37

8993

FKM

321K4706

2995

120

FKM

321K4706

100

FKM

321K4756

-10

120

FKM

321K4756

-10

100

NBR

E321G37

Power

Coil
Group

Dwg.
No.

7098

481180

AC
W
4

DC
W
5

1.1

488980

2.5

1.1

7098

481865

2.1/3.0

7100

4270

481000

2.1/3.0

7100

2995

481865

2.1/3.0

7100

4270

481000

2.1/3.0

7100

2995

481865

2.0

3442

25

180 10.8 14000

0.3

16

16

-10

100

NBR

E321G37

4270

481000

2.0

3442

28

270 16.2 18000

0.3

16

16

-10

100

NBR

E321G38

2995

481865

2.0

3442

28

270 16.2 18000

0.3

16

16

-10

100

NBR

E321G38

40

420 25.2 31500

0.3

16

-10

100

NBR

E321G39

40

420 25.2 31500

0.3

16

8.5

-10

100

NBR

E321G39

40

540 32.4 40000

0.3

16

-10

100

NBR

E321G40

40

540 32.4 40000

0.3

16

8.5

-10

100

NBR

E321G40

4270

481000

2.0

3442

2995

481865

2.0

3442

4270

481000

2.0

3442

2995

481865

2.0

3442

4270

481000

2.0

3442

Notes:
1.Pilot seat disc in synthetic Ruby
2.With manual override

104

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1''

18

110

-10

-10

To

2''

40

540

16

120

50

Drawing 7098

Drawing 7100

Drawing 3442

105

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR WATER AND NEUTRAL LIQUIDS


PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY OPEN
Port size Orice

Flow
factors

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Valve Order
Min Max(MOPD) Min Max
Number
Kv KV Qn
AC DC
l/min m3/h m3/h bar bar bar C C
50
3
0.1 10 10 -10 140 EPDM 444600W

Power

Parker Valves
Valve
Type

Coil
Type

Coil
Group

Dwg.
No.

481865

AC
W
8

DC
W
9

2.0

060

481865

2.0

060

7322BIV00

481865

2.0

060

444601W

7322BAH00

481865

2.0

060

NBR

443806W

7322BAN00

481865

2.0

060

FKM

444500W

7322BAV00

481865

2.0

060

-10

140 EPDM

444602W

7322BCH00

481865

2.0

061

20

-10

90

NBR

443807W

7322BCN00

481865

2.0

061

20

20

-10

140

FKM

444501W

7322BCV00

481865

2.0

061

0.1

10

10

-10

140 EPDM

444603W

7322BDH00

481865

2.0

061

0.1

20

20

-10

90

NBR

443808W

7322BDN00

481865

2.0

061

9.6

0.1

20

20

-10

140

FKM

444502W

7322BDV00

481865

2.0

061

35

420 25.2

0.1

10

10

-10

140 EPDM

444576W

7322BEH00

481865

2.0

062

35

420 25.2

0.1

10

10

-10

90

443809W

7322BEN00

481865

2.0

062

40

500

30

0.1

10

10

-10

140 EPDM

444604W

7322BFH00

481865

2.0

062

40

500

30

0.1

10

10

-10

90

443810W

7322BFN00

481865

2.0

062

50

620 37.2

0.1

10

10

-10

140 EPDM

444605W

7322BGH00

481865

2.0

062

50

620 37.2

0.1

10

10

-10

90

NBR

443811W

7322BGN00

481865

2.0

062

2 1/2''

65

1100 66

0.2

10

10

-10

90

NBR

444513W

7322BLN06

481865

2.0

063

3''

75

1334 80

0.2

10

10

-10

90

NBR

444503W

7322BMN06

481865

2.0

063

BSP

mm
13

7322BIH00

3/8''

13

50

0.1

20

20

-10

90

NBR

443805W

7322BIN00

13

50

0.1

20

20

-10

140

FKM

444499W

13

50

0.1

10

10

-10

140 EPDM

13

50

0.1

20

20

-10

90

13

50

0.1

20

20

-10

140

20

140

8.4

0.1

10

10

20

140

8.4

0.1

20

20

140

8.4

0.1

25

160

9.6

25

160

9.6

25

160

1/2''

3/4''

1''

1 1/4''
1 1/2''
2''

NBR
NBR

Drawing 062

106

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/8''

13

50

10

-10

-10

To

3''

75

1334

20

140

50

Drawing 060

Drawing 061

Drawing 063

107

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR WATER AND NEUTRAL LIQUIDS


PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY OPEN
Port
size

BSP
1/4''
3/8''

1/2''

3/4''

Orice

Flow
factors

mm
12

Kv KV
Qn
l/min m3/h l/min
32 1.92 2150

Parker LUCIFER
Valves

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
bar bar bar C
C
0.3 12 12 -10 100 FKM

Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

Coil
Group

Dwg.
No.

7094

322K4106

2995

481865

AC
W
8

DC
W
9

12

32

1.92

2150

0.3

12

12

-10

120

FKM

322K4106

4270

481000

2.1
2.1

7094

12

45

2.7

3050

0.3

12

12

-10

100

FKM

322K4306

2995

481865

2.1

7094

12

45

2.7

3050

0.3

12

12

-10

120

FKM

322K4306

4270

481000

2.1

7094

12

50

3400

0.3

12

12

-10

100

FKM

322K4506

2995

481865

2.1

7094

12

50

3400

0.3

12

12

-10

120

FKM

322K4506

4270

481000

2.1

7094

15

60

3.6

3890

0.3

15

15

-10

100

NBR

322G75

2995

481865

2.1

3522

15

60

3.6

3890

0.3

15

15

-10

100

NBR

322G75

4270

481000

2.1

3522

18

100

9400

0.3

12

12

-10

100

FKM

322K4606

2995

481865

2.1

7099

18

100

9400

0.3

12

12

-10

120

FKM

322K4606

4270

481000

2.1

7099

20

135

8.1

9500

0.3

16

16

-10

100

NBR

322G36

2995

481865

2.1

3442

20

135

8.1

9500

0.3

16

16

-10

100

NBR

322G36

4270

481000

2.1

3442

Drawing 3442

108

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

12

32

12

-10

-10

To

3/4''

20

135

16

120

50

Drawing 7094

Drawing 3522

Drawing 7099

109

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR WATER AND NEUTRAL LIQUIDS


PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY OPEN
Port
size

BSP

1''

1 1/2''

Orice

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.

Housing
Ref.

Coil
Ref.

mm
18

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV
Qn
AC DC
l/min m3/h l/min bar bar bar C
C
110 6.6 10150 0.3 12 12 -10 100 FKM

322K4706

2995

18

110

10150

0.3

12

12

-10

120

FKM

322K4706

4270

25

180 10.8 14000

0.3

16

16

-10

100

NBR

322G37

25

180 10.8 14000

0.3

16

16

-10

100

NBR

40

420 25.2 31500

0.3

12

12

-10

100

40

420 25.2 31500

0.3

12

12

-10

100

6.6

Power

Coil
Group

Dwg.
No.

481865

AC
W
8

DC
W
9

2.0

7100

481000

2.0

7100

2995

481865

2.1

3442

322G37

4270

481000

2.1

3442

NBR

322G39

2995

481865

2.1

3442

NBR

322G39

4270

481000

2.1

3442

Coil
Group

Dwg.
No.

BRASS
SUB-BASE MOUNTING

NORMALLY CLOSED
Port
size

Orice

mm
14
SB

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
45 2.7 2100 0.3 40 25 -10 100 NBR

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.
E321F32

14

45

2.7 2100 0.3

40

30

-10

100

NBR

E321F32

14

45

2.7 2100 0.3

40

40

-10

100

NBR

E321F32

Housing
Ref.

Coil
Ref.

2995

4270

4270

Power

481865

AC
W
8

DC
W
9

2.0

3520

481000

2.0

3520

486265

14

14

2.0

3520

Notes:
1.Pilot seat disc in synthetic Ruby

110

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

14 mm

14

45

12

-10

-10

To

1 1/2''

40

420

40

120

50

Drawing 7100

Drawing 3442

Drawing 3520

111

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

112

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

ANTI WATER HAMMER VALVES

Water

Actuation
Magnalift
Pilot
Operated

Body
Brass/Pipe mounting
Brass/Pipe mounting

Function
Normally Closed
Normally Closed

Normally Open

2/2

Port
Size

Orice
(mm)

Flow
Factor
Kv(l/min)

MOPD
(bar)

Max
Fluid
Temp. (C)

Page

Page

Parker
Valves

Parker
LUCIFER
Valves

1''
1/4''
3/8''
1/2''
3/4''
1''
1 1/4''
1 1/2''
2''
2 1/2''
3''
3/4''
1''
1 1/4''
1 1/2''
2''

15 to 25
12
12
12
18 to 20
18 to 25
25 to 28
35 to 40
40 to 50
65
75
20
25
28
40
40

170
32
45
50
135
180
280
500
620
1100
1334
135
180
270
425
540

10
12
12
12
16
16
16
16
16
10
10
16
16
16
12
12

140
120
120
120
120
120
100
100
100
90
90
100
100
100
100
100

116
116
116
116
116
116
-

114
118
118
118
118
120
120
120
120
122
122
122
122
122

113

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

ANTI WATER HAMMER VALVES


MAGNALIFT

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

1''

Orice

Flow
factors

mm
15

Qn
Kv KV
l/min m3/h l/min
80 4.8 6000

Operating
Fluid
Pressure
Temp.
Differential
Min Max(MOPD) Min Max
AC DC
bar bar bar C
C
0
10 -10 100

Parker LUCIFER
Valves

Seat
Seal

Valve
Ref.

Housing
Ref.

Power

Coil
Ref.

DC
W
9

Coil
Group

Dwg.
No.

FKM

221G1731

12

2995

481865

AC
W
-

2.1

3445

15

80

4.8

6000

10

10

-10

120

FKM

221G1731

12

492070

2.1

3445

15

80

4.8

6000

10

10

-10

120

FKM

221G1731

12

492190

11

2.1

3445

25

160

9.6

10

100 EPDM

221G2103

2995

481865

2.0

3448

25

160

9.6

10

120 EPDM

221G2103

4270

481000

2.0

3448

25

160

9.6

10

10

120 EPDM

221G2103

4270

486265

14

14

2.0

3448

25

160

9.6

140 EPDM

221G2103

2995

492425

14

14

2.0

3448

25

170 10.2 14000

10

-10

100

FKM

221G2131

12

2995

481865

2.1

3448

25

170 10.2 14000

10

10

-25

40

FKM

221G2131

12

492070

2.1

3448

25

170 10.2 14000

10

10

-25

40

FKM

221G2131

12

492190

11

2.1

3448

Notes:
1.Valves with model number ending in 30 or 31 are mainly equipped with electrical parts for explosion proof applications or with standard DC coils.
2.With 4 position selector for controlled closure rate

114

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1''

15

80

-25

-10

To

1''

25

170

10

140

50

Drawing 3445

Drawing 3448

115

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

ANTI WATER HAMMER VALVES


PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

Orice

Flow
factors

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
Kv
KV Qn
l/min m3/h m3/h bar bar bar C C
140 8.4
0.1 10 10 -10 90 NBR

Power

Parker Valves
Valve Order
Number

Valve
Type

Coil
Type

Coil
Group

Dwg.
No.

057

1''

mm
20

443784W 1

7321BCN02

481865

AC
W
8

1 1/4''

25

160

9.6

0.1

10

10

-10

90

NBR

443788W 1

7321BDN02

481865

2.0

057

35

420 25.2

0.1

-10

90

NBR

443792W 1

7321BEN02

481865

2.0

058
058

BSP

1 1/2''

DC
W
9

2.0

40

500

0.1

-10

90

NBR

443796W 1

7321BFN02

481865

2.0

2''

50

620 37.2

0.1

-10

90

NBR

443800W 1

7321BGN02

481865

2.0

058

2 1/2''

65

1100

66

0.2

10

10

-10

90

NBR

443802W 1

7321BLN02

481865

2.0

059

3''

75

1334

80

0.2

10

10

-10

90

NBR

443803W 1

7321BMN02

481865

2.0

059

30

Notes:
1.With manual override

116

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1''

20

140

-10

-10

To

3''

75

1334

10

90

50

Drawing 057

Drawing 058

Drawing 059

117

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

ANTI WATER HAMMER VALVES


PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP
1/4''
3/8''

1/2''

3/4''

Orice

Flow
factors
Qn
l/min
2150

Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

DC
W
9

Coil
Group

Dwg.
No.

321K4106

2995

481865

AC
W
8

2.1/3.0

7094

12

32

1.92

2150

0.3

12

12

-10

120

NBR

321K4106

4270

481000

2.1/3.0

7094

12

45

2.7

3050

0.3

12

12

-10

100

FKM

321K4306

2995

481865

2.1/3.0

7094

12

45

2.7

3050

0.3

12

12

-10

120

FKM

321K4306

4270

481000

2.1/3.0

7094

12

50

3400

0.3

12

12

-10

100

FKM

321K4506

2995

481865

2.1/3.0

7094

12

50

3400

0.3

12

12

-10

120

FKM

321K4506

4270

481000

2.1/3.0

7094

12

50

3400

0.3

12

12

-10

100

FKM

321K4556

2995

481865

2.1/3.0

7094

12

50

3400

0.3

12

12

-10

120

FKM

321K4556

4270

481000

2.1/3.0

7094

18

100

9400

0.3

12

12

-10

100

FKM

321K4606

2995

481865

2.1/3.0

7099

18

100

9400

0.3

12

12

-10

120

FKM

321K4606

4270

481000

2.1/3.0

7099

18

100

9400

0.3

12

12

-10

100

FKM

321K4656

2995

481865

2.1/3.0

7099

18

100

9400

0.3

12

12

-10

120

FKM

321K4656

4270

481000

2.1/3.0

7099

20

135

8.1

9500

16

16

-10

100

NBR

E321G3610

2995

481865

2.0

3442

20

135

8.1

9500

16

16

-10

100

NBR

E321G3610

4270

481000

2.0

3442

mm
12

Kv KV
l/min m3/h
32 1.92

Parker LUCIFER
Valves

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
bar bar bar C
C
0.3 12 12 -10 100 NBR

Notes:
1.With manual override
2.With manual override and 4 position selector for controlled closure rate - without manual override and without 4 position selector on request: use same reference removing sufx '10',
e.g. E321G36

118

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

12

32

12

-10

-10

To

3/4''

20

135

16

120

50

Drawing 7094

Drawing 7099

Drawing 3442

119

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

ANTI WATER HAMMER VALVES


PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

1''

1 1/4''
1 1/2''
2''

Orice

Flow
factors

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

mm
18

Kv KV
Qn
l/min m3/h l/min
110 6.6 10150

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
bar bar bar C
C
0.3 12 12 -10 100 FKM

321K4706

2995

18

110

6.6

10150

0.3

12

12

-10

120

FKM

321K4706

4270

18

110

6.6

10150

0.3

12

12

-10

100

FKM

321K4756

18

110

6.6

10150

0.3

12

12

-10

120

FKM

321K4756

25

180 10.8 14000

0.3

16

16

-10

100

NBR

E321G3710

25

180 10.8 14000

0.3

16

16

-10

100

NBR

E321G3710

28

280 16.8 18000

0.3

16

16

-10

100

NBR

E321G3810

28

280 16.8 18000

0.3

16

16

-10

100

NBR

E321G3810

40

420 25.2 31500

0.3

16

-10

100

FKM

E321G3910

40

420 25.2 31500

0.3

16

8.5

-10

100

FKM

40

540 32.4 40000

0.3

16

-10

100

40

540 32.4 40000

0.3

16

8.5

-10

100

Power

Coil
Group

Dwg.
No.

7100

481865

AC
W
8

DC
W
9

2.1/3.0

481000

2.1/3.0

7100

2995

481865

2.1/3.0

7100

4270

481000

2.1/3.0

7100

2995

481865

2.0

3442

4270

481000

2.0

3442

2995

481865

2.0

3442

4270

481000

2.0

3442

2995

481865

2.0

3442

E321G3910

4270

481000

2.0

3442

FKM

E321G4010

2995

481865

2.0

3442

FKM

E321G4010

4270

481000

2.0

3442

Notes:
1.With manual override
2.With manual override and 4 position selector for controlled closure rate - without manual override and without 4 position selector on request: use same reference removing sufx '10',
e.g. E321G36

120

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1''

18

110

-10

-10

To

2''

40

540

16

120

50

Drawing 7100

Drawing 3442

121

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

ANTI WATER HAMMER VALVES


PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY OPEN
Port
size

BSP
3/4''
1''
1 1/4''
1 1/2''
2''

Orice

Flow
factors

Parker LUCIFER
Valves

mm
20

Kv KV
Qn
l/min m3/h l/min
135 8.1 9300

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
bar bar bar C
C
0.3 16 16 -10 100 NBR

322G3610

20

135

9300

0.3

16

16

-10

100

NBR

322G3610

25

180 10.8 14000

0.3

16

16

-10

100

NBR

322G3710

25

180 10.8 14000

0.3

16

16

-10

100

NBR

28

270 16.2 18000

0.3

16

16

-10

100

28

270 16.2 18000

0.3

16

16

-10

40

425 25.5 31000

0.3

12

12

40

425 25.5 31000

0.3

12

40

540 32.4 40000

0.3

40

540 32.4 40000

0.3

8.1

Valve
Ref.

Housing
Ref.

Coil
Ref.

2995

4270

322G3710

NBR

100

-10

12

12
12

Power

Coil
Group

Dwg.
No.

481865

AC
W
8

DC
W
9

2.1

3442

481000

2.1

3442

2995

481865

2.1

3442

4270

481000

2.1

3442

322G3810

2995

481865

2.1

3442

NBR

322G3810

4270

481000

2.1

3442

100

NBR

322G3910

2995

481865

2.1

3442

-10

100

NBR

322G3910

4270

481000

2.1

3442

12

-10

100

NBR

322G4010

2995

481865

2.1

3442

12

-10

100

NBR

322G4010

4270

481000

2.1

3442

Notes:
1.With 4 position selector for controlled closure rate

122

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/4''

20

135

12

-10

-10

To

2''

40

540

16

100

50

Drawing 3442

123

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

124

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

HOT WATER AND STEAM VALVES

100

Steam

Actuation
Direct
Operated

Magnalift

Pilot
Operated

Body

Function

Water

2/2

Port
Size

Orice
(mm)

Flow
Factor
Kv(l/min)

MOPD
(bar)

Max
Fluid
Temp. (C)

Page

Page

Parker
Valves

Parker
LUCIFER
Valves

3.2
11
12
36

30
30
5
4

140
180
140
120

126
126
-

128
128
128

Brass/Pipe mounting

Normally Closed

1/8''
1/4''
3/8''
1/2''

2.5
2.5 to 5
6
8.5 to 11

303 Stainless St./Pipe


mounting
Brass/Pipe mounting

Normally Closed

1/4''

1.5 to 5

10

100

180

130

Normally Closed

Brass/Pipe mounting

Normally Closed

3/8''
1/2''
3/4''
1''
3/8''
1/2''
3/4''
1''

15
15
15
15
10 to 16
10 to 16
18 to 27
18 to 27

65
65
80
80
78
78
193
193

10
10
10
10
16
16
14
14

140
140
140
140
180
180
180
180

134
134
136
136

132
132
132
132
138
-

125

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

HOT WATER AND STEAM VALVES


MAGNALIFT

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port Orice
size

BSP
1/8''

1/4''

mm
2.5
2.5

Flow
factors

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h m3/h bar bar bar C C
3.2 0.192 0
30
-30 140 Ruby
3.2 0.192

17

-30

140 Ruby

Power

Parker Valves
Valve Order
Number

Valve
Type

Coil
Type

362496J

PM140IR

ZB09

AC
W
9

362496J

PM140IR

ZB12

Coil
Group

Dwg.
No.

DC
W
-

20.1/20.2

027

12

20.1/20.2

027

2.5

3.2 0.192

30

-30

140 Ruby

362518J 1

PM140CR

ZB09

20.1/20.2

026

2.5

3.2 0.192

17

-30

140 Ruby

362518J 1

PM140CR

ZB12

12

20.1/20.2

026

2.5

3.2 0.192

30

-30

140 Ruby

362518J 1

PM140CR

ZH14

14

20.1/20.2

026

2.5

3.2 0.192

17

-30

140 Ruby

362518J 1

PM140CR

ZH16

16

20.1/20.2

026

4.2 0.25

10

-10

140 EPDM

360470 2

PM126YH

ZB09

20.1/20.2

008

4.2 0.25

-10

140 EPDM

360470 2

PM126YH

ZB12

12

20.1/20.2

008

4.2 0.25

10

-10

140 EPDM

360470 2

PM126YH

ZH14

14

20.1/20.2

008

4.2 0.25

-10

140 EPDM

360470 2

PM126YH

ZH16

16

20.1/20.2

008

4.2 0.25

10

-10

180 PTFE

360475 2

PM126YT

ZH14

14

20.1/20.2

008

4.2 0.25

10

-10

180 PTFE

360475 2

PM126YT

ZH16

16

20.1/20.2

008

30

-30

140 Ruby

362524J

PM140DR

ZB09

20.1/20.2

026

0.24

0.24

12

-30

140 Ruby

362524J

PM140DR

ZB12

12

20.1/20.2

026

0.24

30

-30

140 Ruby

362524J

PM140DR

ZH14

14

20.1/20.2

026
026

0.24

12

-30

140 Ruby

362524J

PM140DR

ZH16

16

20.1/20.2

3.3

0.2

10

-10

140 EPDM

364880J 2

PM158IH

ZH14

14

20.2

042

3.3

0.2

-10

140 EPDM

364880J 2

PM158IH

ZH16

16

20.2

042

3.3

0.2

10

-10

180 PTFE

364884J 2

PM158IT

ZH14

14

20.2

042

3.3

0.2

10

-10

180 PTFE

364884J 2

PM158IT

ZH16

16

20.2

042

Notes:
1.DIN-EN-ISO 23553-1 (2009-10) approved for oil burners
2.Maximum pressure for steam: 4 Bar (140C)

126

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

2.5

3.2

-30

-10

To

1/4''

4.2

30

180

50

Drawing 027

Drawing 026

Drawing 008

Drawing 042

127

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

HOT WATER AND STEAM VALVES


DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

1/4''

3/8''

1/2''

Orice

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
4.5 0.27 0
10
7
0 100 EPDM

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

Dwg.
No.

121K0323

2995

481865

AC
W
8

2.0

3510

4.5 0.27

10

8.5

120 EPDM

121K0323

4270

481000

2.0

3510

4.5 0.27

10

10

120 EPDM

121K0323

4270

486265

14

14

2.0

3510

4.5 0.27

10

10

120 EPDM

121K0323

2995

492425

14

14

2.0

3510

11

0.66 750

100 EPDM

121K0103

2995

481865

2.0

3510

11

0.66 750

2.8

120 EPDM

121K0103

4270

481000

2.0

3510

11

0.66 750

120 EPDM

121K0103

4270

486265

14

14

2.0

3510

11

0.66 750

3.5

120 EPDM

121K0103

2995

492425

14

14

2.0

3510

11

0.66 750

100

FKM

121K0113

2995

481865

2.0

3510

12

0.72 1100

1.1

100 EPDM

121K3303

2995

481865

2.0

3551

12

0.72 1100

1.5

120 EPDM

121K3303

4270

481000

2.0

3551

12

0.72 1100

120 EPDM

121K3303

4270

486265

14

14

2.0

3551

12

0.72 1100

140 EPDM

121K3303

2995

492425

14

14

2.0

3551

8.5

25

1.5

2.2

0.5

120 EPDM

E121K4603

4270

481000

2.0

3427

8.5

25

1.5

1.2

120 EPDM

E121K4603

4270

486265

14

14

2.0

3427

8.5

25

1.5

120 EPDM

E121K4603

2995

492425

14

14

2.0

3427

11

36

2.16

1.2 0.35

120 EPDM

E121K4503

4270

481000

2.0

3427

11

36

2.16

2.5

0.7

120 EPDM

E121K4503

4270

486265

14

14

2.0

3427

11

36

2.16

2.5

0.5

120 EPDM

E121K4503

2995

492425

14

14

2.0

3427

mm
3

128

DC
W
9

Coil
Group

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

4.5

0.4

-10

To

1/2''

11

36

10

140

50

Drawing 3510

Drawing 3551

Drawing 3427

129

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

HOT WATER AND STEAM VALVES


DIRECT OPERATED

303 STAINLESS ST.


PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

1/4''

Orice

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
1.5 0.09 80
0
60 25
0 100 Ruby

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

Dwg.
No.

121V5463

2995

481865

AC
W
8

2.0

8116

1.5

1.5 0.09

80

75

30

130 Ruby

121V5463

4270

481000

2.0

8116

1.5

1.5 0.09

80

100

55

140 Ruby

121V5463

4270

486265

14

14

2.0

8116

2.5

3.5 0.21 220

28

10

100 Ruby

121V5763

2995

481865

2.0

8116

2.5

3.5 0.21 220

34

12

130 Ruby

121V5763

4270

481000

2.0

8116

2.5

3.5 0.21 220

50

22

140 Ruby

121V5763

4270

486265

14

14

2.0

8116

4.5 0.27 315

20

100 Ruby

121V5363

2995

481865

2.0

8116

4.5 0.27 315

25

8.5

130 Ruby

121V5363

4270

481000

2.0

8116

4.5 0.27 315

36

15

140 Ruby

121V5363

4270

486265

14

14

2.0

8116

mm
1.5

DC
W
9

Coil
Group

0.42 450

12

100 Ruby

121V5263

2995

481865

2.0

8116

0.42 450

15

130 Ruby

121V5263

4270

481000

2.0

8116

0.42 450

22

10

180 Ruby

121V5263

4270

486265

14

14

2.0

8116

10

0.6

750

8.5

100 Ruby

121V5163

2995

481865

2.0

8116

10

0.6

750

10

3.5

130 Ruby

121V5163

4270

481000

2.0

8116

10

0.6

750

14

6.5

140 Ruby

121V5163

4270

486265

14

14

2.0

8116

Notes:

130

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

1.5

1.5

-10

To

1/4''

10

100

180

50

Drawing 8116

131

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

HOT WATER AND STEAM VALVES


MAGNALIFT

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

3/8''

1/2''

3/4''

1''

Orice

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
Kv KV Qn
C
l/min m3/h l/min bar bar bar C
65 3.9
0
10
0 100 EPDM

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

Dwg.
No.

221G1303

2995

481865

AC
W
8

2.0

3732

15

65

3.9

10

120 EPDM

221G1303

4270

481000

2.0

3732

15

65

3.9

140 EPDM

221G1303

4270

486265

14

14

2.0

3732

15

65

3.9 4500

10

10

-10

100

FKM

221G1330

2995

481865

2.1

3732

15

65

3.9 4500

10

10

-10

120

FKM

221G1330

492070

2.1

3732

15

65

3.9 4500

10

10

-10

120

FKM

221G1330

492190

11

2.1

3732

15

65

3.9

10

100 EPDM

221G1503

2995

481865

2.0

3732

mm
15

DC
W
-

Coil
Group

15

65

3.9

10

120 EPDM

221G1503

4270

481000

2.0

3732

15

65

3.9

10

140 EPDM

221G1503

4270

486265

14

14

2.0

3732

15

80

4.8

10

100 EPDM

221G1603

2995

481865

2.0

3444

15

80

4.8

10

120 EPDM

221G1603

4270

481000

2.0

3444

15

80

4.8

140 EPDM

221G1603

4270

486265

14

14

2.0

3444

15

80

4.8

10

100 EPDM

221G1703

2995

481865

2.0

3445

15

80

4.8

10

120 EPDM

221G1703

4270

481000

2.0

3445

15

80

4.8

10

10

140 EPDM

221G1703

4270

486265

14

14

2.0

3445

Notes:
1.Valves with model number ending in 30 or 31 are mainly equipped with electrical parts for explosion proof applications or with standard DC coils.

132

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/8''

15

65

-10

-10

To

1''

15

80

10

140

50

Drawing 3732

Drawing 3444

Drawing 3445

133

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

HOT WATER AND STEAM VALVES


PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port Orice
size

Flow
factors

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h m3/h bar bar bar C C
22 1.32 0.5 16
-30 160 PTFE

BSP

mm
10

3/8''

16

78

16
10
1/2''

Power

Parker Valves
Valve Order
Number

Valve
Type

Coil
Type

Dwg.
No.

364520 1

PM156.2IR

ZB09

AC
W
9

20.1

041

10

-30

180 PTFE

362262

PM135IT

ZH14

14

20.1/20.2

017

0.5

10

-30

180 PTFE

362262

PM135IT

ZH16

16

20.1/20.2

017

0.5

16

-30

160 PTFE

364525 1

PM156.2AR

ZB09

20.1

038

0.5

10

-30

180 PTFE

362263

PM135AT

ZH14

14

20.1/20.2

016

0.5

10

-30

180 PTFE

362263

PM135AT

ZH16

16

20.1/20.2

016

4.7

0.5

78

4.7

24

1.44

16

78

4.7

16

78

4.7

DC
W
-

Coil
Group

Notes:
1.Maximum pressure for steam: 6.5 Bar (160C)

134

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/8''

10

22

10

-30

-10

To

1/2''

16

78

16

180

50

Drawing 041

Drawing 017

Drawing 038

Drawing 016

135

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

HOT WATER AND STEAM VALVES


PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port Orice
size

Flow
factors

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
3
3
l/min m /h m /h bar bar bar C C
37 2.22 0.5 14
-30 160 PTFE

Valve Order
Number

Valve
Type

Coil
Type

Dwg.
No.

364530 1

PM156.2CR

ZB09

20.1

039

10

-30

180 PTFE

362264

PM135CT

ZH14

14

20.1/20.2

018

0.5

10

-30

180 PTFE

362264

PM135CT

ZH16

16

20.1/20.2

018

0.5

14

-30

160 PTFE

364535 1

PM156.2DR

ZB09

20.1

040

0.5

10

-30

180 PTFE

362265

PM135DT

ZH14

14

20.1/20.2

019

0.5

10

-30

180 PTFE

362265

PM135DT

ZH16

16

20.1/20.2

019

mm
18

3/4''

27

193 11.6

0.5

27

193 11.6

18

42

2.52

27

193 11.6

27

193 11.6

DC
W
-

Coil
Group

AC
W
9

BSP

1''

Power

Parker Valves

Notes:
1.Maximum pressure for steam: 6.5 Bar (160C)

136

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/4''

18

37

10

-30

-10

To

1''

27

193

14

180

50

Drawing 039

Drawing 018

Drawing 040

Drawing 019

137

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

HOT WATER AND STEAM VALVES


PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

Orice

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
36 2.16 0.2 10
4
0 120 EPDM

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.

Housing
Ref.

BSP

mm
11

E321K1503

4270

1/2''

11

36

2.16

0.2

10

100 EPDM

E321K1503

4270

11

36

2.16

0.2

10

120 EPDM

E321K1503

4270

138

Coil
Ref.

Power

Coil
Group

Dwg.
No.

481000

AC
W
8

DC
W
8

2.0

3427

483520

2.0

3427

486992

10

2.0

3427

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/2''

11

36

-10

To

1/2''

11

36

10

120

50

Drawing 3427

139

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

140

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

VALVES FOR HYDRAULIC OIL AND


NEUTRAL LIQUIDS (UP TO 100 BAR)

Oil

Actuation
Direct
Operated

Body
Brass/Pipe mounting

Pilot
Operated

Orice
(mm)

Flow
Factor
Kv(l/min)

MOPD
(bar)

Max
Fluid
Temp. (C)

Page

Page

Parker
Valves

Parker
LUCIFER
Valves

1/8''
1/4''
3/8''
1/8''
1/4''

1.5 to 2.5
1.2 to 3
4 to 6
2.5
1.5 to 2.5

3.5
4.5
12
3.5
3.5

70
100
10
30
40

130
130
120
140
140

142
142
144
144
144

Normally Closed

5 mm

1.5 to 3

4.5

100

130

146

Normally Closed

1/4''
3/8''
1/2''
1/4''
3/8''
1/2''
14 mm
14 mm

8
11
15
8
11
15
14
14

36
50
60
36
50
60
45
45

40
40
40
40
40
40
40
40

140
140
140
140
140
140
140
120

148
148
150
152
152
152
154
154

Normally Closed

Normally Open

Brass/Sub-base
mounting

2/2

Port
Size

Function

Normally Open
Brass/Sub-base
mounting
Brass/Pipe mounting

Water

Normally Closed
Normally Open

141

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR HYDRAULIC OIL AND NEUTRAL


LIQUIDS (UP TO 100 BAR)
DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

1/8''

1/4''

Orice

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
Kv KV Qn
C
l/min m3/h l/min bar bar bar C
1.5 0.09 80
0
60 25 -30 75 PCTFE

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

Dwg.
No.

E121K14

2995

481865

AC
W
8

2.0

3510

1.5

1.5 0.09

80

70

30

-30

75 PCTFE

E121K14

4270

481000

2.0

3510

1.5

1.5 0.09

80

70

55

-30

75 PCTFE

E121K14

4270

486265

14

14

2.0

3510

2.5

3.5 0.21 220

28

10

-30

100 Ruby

E121K23

2995

481865

2.0

3510

2.5

3.5 0.21 220

34

12

-30

130 Ruby

E121K23

4270

481000

2.0

3510

2.5

3.5 0.21 220

50

22

-30

120 Ruby

E121K23

4270

486265

14

14

2.0

3510

1.2

0.85 0.051 50

80

36

-30

100 Ruby

E121K65

2995

481865

2.0

3510

1.2

0.85 0.051 50

100

43

-30

130 Ruby

E121K65

4270

481000

2.0

3510

1.2

0.85 0.051 50

100

75

-30

120 Ruby

E121K65

4270

486265

14

14

2.0

3510

1.5

1.5 0.09

80

60

25

-30

75 PCTFE

E121K04

2995

481865

2.0

3510

1.5

1.5 0.09

80

70

30

-30

75 PCTFE

E121K04

4270

481000

2.0

3510

1.5

1.5 0.09

80

70

55

-30

75 PCTFE

E121K04

4270

486265

14

14

2.0

3510

1.5

1.5 0.09

80

60

25

-30

100 Ruby

E121K67

2995

481865

2.0

3510

1.5

1.5 0.09

80

75

30

-30

130 Ruby

E121K67

4270

481000

2.0

3510

1.5

1.5 0.09

80

100

55

-30

120 Ruby

E121K67

4270

486265

14

14

2.0

3510

2.5

3.5 0.21 220

28

10

-30

100 Ruby

E121K63

2995

481865

2.0

3510

2.5

3.5 0.21 220

34

12

-30

130 Ruby

E121K63

4270

481000

2.0

3510

2.5

3.5 0.21 220

50

22

-30

120 Ruby

E121K63

4270

486265

14

14

2.0

3510

4.5 0.27 320

20

-30

75 PCTFE

E121K03

2995

481865

2.0/3.0

3510

4.5 0.27 320

25

8.5

-30

75 PCTFE

E121K03

4270

481000

2.0/3.0

3510

mm
1.5

142

DC
W
9

Coil
Group

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

1.2

0.85

-30

-10

To

1/4''

4.5

100

130

50

Drawing 3510

143

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR HYDRAULIC OIL AND NEUTRAL


LIQUIDS (UP TO 100 BAR)
DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

Orice

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
4.5 0.27 320 0
36 15 -30 75 PCTFE

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.

Housing
Ref.

Coil
Ref.

Coil
Group

Dwg.
No.

486265

AC
W
14

DC
W
14

2.0/3.0

3510

481865

2.0

3510

4270

481000

2.0

3510

E121K64

4270

486265

14

14

2.0

3510

FKM

121K3206

2995

481865

2.0

3551

120

FKM

121K3206

4270

481000

2.0

3551

120

FKM

121K3206

4270

486265

14

14

2.0

3551

-10

100

FKM

121K3106

2995

481865

2.0

3551

2.8

-10

120

FKM

121K3106

4270

481000

2.0

3551

-10

120

FKM

121K3106

4270

486265

14

14

2.0

3551

1.1

-10

100

FKM

121K3306

2995

481865

2.0/14.2

3551

0.72 1100

1.5

-10

120

FKM

121K3306

4270

481000

2.0/14.2

3551

0.72 1100

-10

120

FKM

121K3306

4270

486265

14

14

2.0/14.2

3551

Coil
Group

Dwg.
No.

BSP

mm
3

E121K03

4270

1/4''

4.5 0.27 320

20

-30

100 Ruby

E121K64

2995

4.5 0.27 320

25

8.5

-30

130 Ruby

E121K64

4.5 0.27 320

36

15

-30

120 Ruby

7.5 0.45 480

10

-10

100

7.5 0.45 480

10

-10

7.5 0.45 480

10

10

-10

11

0.66 750

11

0.66 750

11

0.66 750

12

0.72 1100

12

12

3/8''

Power

BRASS
PIPE MOUNTING

NORMALLY OPEN
Port
size

BSP
1/8''

1/4''

Orice

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
3.5 0.21 0
30
-30 140 Ruby

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

122K9363

4270

481044

AC
W
14

2.2

3510

30

30

-30

140 Ruby

122K9363

4270

486265

14

14

2.2

3510

1.5 0.09 9.6

30

30

-10

100 PCTFE

122K84

2995

481865

2.1

3510

1.5

1.5 0.09 9.6

30

30

-10

100 PCTFE

122K84

4270

481000

2.1

3510

1.5

1.5 0.09 9.6

30

30

-10

120 PCTFE

122K84

4270

486265

14

14

2.0

3510

1.5

1.5 0.09

80

40

40

-30

100 Ruby

122K8408

2995

481865

2.1

3510

1.5

1.5 0.09

80

40

40

-30

130 Ruby

122K8408

4270

481000

2.1

3510

1.5

1.5 0.09

80

40

40

-30

130 Ruby

122K8408

4270

486265

14

14

2.0

3510

2.5

3.5 0.21

30

-30

140 Ruby

122K8363

4270

481044

14

2.2

3510

2.5

3.5 0.21

30

30

-30

140 Ruby

122K8363

4270

486265

14

14

2.2

3510

mm
2.5
2.5

3.5 0.21

1.5

144

DC
W
-

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

1.5

1.5

1.1

-30

-10

To

3/8''

12

40

140

50

Drawing 3510

Drawing 3551

145

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR HYDRAULIC OIL AND NEUTRAL


LIQUIDS (UP TO 100 BAR)
DIRECT OPERATED

BRASS
SUB-BASE MOUNTING

NORMALLY CLOSED
Port
size

Orice

Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

Dwg.
No.

121F67

2995

481865

2.0

3509

1.5

1.5 0.09

80

75

30

-30

130 Ruby

121F67

4270

481000

2.0

3509

1.5

1.5 0.09

80

100

55

-30

120 Ruby

121F67

4270

486265

14

14

2.0

3509

1.5

1.5 0.09

80

60

25

-30

75 PCTFE

E121F44

2995

481865

2.0

3509

1.5

1.5 0.09

80

70

30

-30

75 PCTFE

E121F44

4270

481000

2.0

3509

1.5

1.5 0.09

80

70

55

-30

75 PCTFE

E121F44

4270

486265

14

14

2.0

3509

2.5

3.5 0.21 220

14

-10

100

FKM

121F4706

2995

481865

2.0

3509

2.5

3.5 0.21 220

14

-10

120

FKM

121F4706

4270

481000

2.0

3509

2.5

3.5 0.21 220

14

14

-10

120

FKM

121F4706

4270

486265

14

14

2.0

3509

2.5

3.5 0.21 220

28

10

-30

100 Ruby

121F63

2995

481865

2.0

3509

2.5

3.5 0.21 220

34

12

-30

130 Ruby

121F63

4270

481000

2.0

3509

2.5

3.5 0.21 220

50

22

-30

120 Ruby

121F63

4270

486265

14

14

2.0

3509

4.5 0.27 320

20

-30

100 Ruby

121F64

2995

481865

2.0

3509

4.5 0.27 320

25

8.5

-30

130 Ruby

121F64

4270

481000

2.0

3509

4.5 0.27 320

36

15

-30

120 Ruby

121F64

4270

486265

14

14

2.0

3509

4.5 0.27 320

20

-30

75 PCTFE

E121F43

2995

481865

2.0

3509

4.5 0.27 320

25

8.5

-30

75 PCTFE

E121F43

4270

481000

2.0

3509

4.5 0.27 320

36

15

-30

75 PCTFE

E121F43

4270

486265

14

14

2.0

3509

146

DC
W
9

Coil
Group

AC
W
8

mm
1.5

SB

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
1.5 0.09 80
0
60 25 -30 100 Ruby

Parker LUCIFER
Valves

Flow
factors

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

5 mm

1.5

1.5

-30

-10

To

5 mm

4.5

100

130

50

Drawing 3509

147

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR HYDRAULIC OIL AND NEUTRAL


LIQUIDS (UP TO 100 BAR)
PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

1/4''

3/8''

Orice

Flow
factors

mm
8

Qn
Kv KV
l/min m3/h l/min
36 2.16 1600

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
bar bar bar C
C
0.3 40 25 -10 100 NBR

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

DC
W
9

Coil
Group

Dwg.
No.

E321H11

124

2995

481865

AC
W
8

2.0

3523

36

2.16 1600

0.3

40

30

-10

100

NBR

E321H11

124

4270

481000

2.0

3523

36

2.16 1600

0.3

40

40

-10

100

NBR

E321H11

124

4270

486265

14

14

2.0

3523

36

2.16

0.3

40

25

-10

100

FKM

E321H21

1234

2995

481865

2.0

3523

36

2.16

0.3

40

30

-10

120

FKM

E321H21

1234

4270

481000

2.0

3523

36

2.16

0.3

40

40

-10

140

FKM

E321H21

1234

4270

486265

14

14

2.0

3523

11

50

2800

0.3

40

25

-10

100

NBR

E321H13

124

2995

481865

2.0

3521

11

50

2800

0.3

40

30

-10

100

NBR

E321H13

124

4270

481000

2.0

3521

11

50

2800

0.3

40

40

-10

100

NBR

E321H13

124

4270

486265

14

14

2.0

3521

11

50

0.3

40

25

-10

100

FKM

E321H23

1234

2995

481865

2.0

3521

11

50

0.3

40

30

-10

120

FKM

E321H23

1234

4270

481000

2.0

3521

11

50

0.3

40

40

-10

140

FKM

E321H23

1234

4270

486265

14

14

2.0

3521

11

36

2.16

0.2

20

-10

100 Ruby

E321K63

2995

483510

2.0

3429

11

36

2.16

0.2

30

-10

140 Ruby

E321K63

4270

488553

2.0

3429

11

36

2.16

0.2

30

-10

120 Ruby

E321K63

492190

11

2.0

3429

Notes:
1.Minimum pressure differential = 0.3 bar for opening and 0 bar for closing
2.Pilot seat disc in synthetic Ruby
3.Valve only compatible with hydraulic oil and neutral liquids
4.With 4 position selector for controlled closure rate

148

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

36

-10

-10

To

3/8''

11

50

40

140

50

Drawing 3523

Drawing 3521

Drawing 3429

149

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR HYDRAULIC OIL AND NEUTRAL


LIQUIDS (UP TO 100 BAR)
PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

1/2''

Orice

Flow
factors

mm
15

Kv KV
Qn
l/min m3/h l/min
60 3.6 3150

Parker LUCIFER
Valves

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
bar bar bar C
C
0.3 40 25 -10 100 NBR

E321H15

Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

DC
W
9

Coil
Group

Dwg.
No.

124

2995

481865

AC
W
8

2.0

3522

15

60

3.6

3150

0.3

40

30

-10

100

NBR

E321H15

124

4270

481000

2.0

3522

15

60

3.6

3150

0.3

40

40

-10

100

NBR

E321H15

124

4270

486265

14

14

2.0

3522

15

60

3.6

0.3

40

25

-10

100

FKM

E321H25

1234

2995

481865

2.0/14.2

3522

15

60

3.6

0.3

40

30

-10

120

FKM

E321H25

1234

483371

2.0/14.2

3522

15

60

3.6

0.3

40

40

-10

140

FKM

E321H25

1234

4270

486265

14

14

2.0/14.2

3522

Notes:
1.Minimum pressure differential = 0.3 bar for opening and 0 bar for closing
2.Pilot seat disc in synthetic Ruby
3.Valve only compatible with hydraulic oil and neutral liquids
4.With 4 position selector for controlled closure rate

150

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/2''

15

60

25

-10

-10

To

1/2''

15

60

40

140

50

Drawing 3522

151

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR HYDRAULIC OIL AND NEUTRAL


LIQUIDS (UP TO 100 BAR)
PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY OPEN
Port
size

Orice

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV
Qn
AC DC
l/min m3/h l/min bar bar bar C
C
36 2.16
0.3 40 40 -10 100 FKM

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.

Housing
Ref.

Coil
Ref.

3523

481865

2.0/14.1

481000

2.0/14.1

3523

4270

486265

14

14

2.0/14.1

3523

1234

2995

1/4''

36

2.16

0.3

40

40

-10

120

FKM

322H7106

1234

4270

36

2.16

0.3

40

40

-10

140

FKM

322H7106

1234

1/2''

Dwg.
No.

DC
W
9

mm
8

3/8''

Coil
Group

AC
W
8

BSP

322H7106

Power

11

50

3240

0.3

40

40

-10

75

NBR

322H73

124

2995

481865

2.0

3523

11

50

3240

0.3

40

40

-10

75

NBR

322H73

124

4270

481000

2.0

3523

11

50

3240

0.3

40

40

-10

75

NBR

322H73

124

4270

486265

14

14

2.0

3523

11

50

0.3

40

40

-10

100

FKM

322H7306

1234

2995

481865

2.0/14.1

3523

11

50

0.3

40

40

-10

100

FKM

322H7306

1234

4270

481000

2.0/14.1

3523

11

50

0.3

40

40

-10

140

FKM

322H7306

1234

4270

486265

14

14

2.0/14.1

3523

15

60

3.6

3890

0.3

20

20

-10

100

FKM

322G7506

13

2995

481865

2.0

3522

15

60

3.6

3890

0.3

20

20

-10

100

FKM

322G7506

13

4270

481000

2.0

3522

15

60

3.6

3890

0.3

20

20

-10

100

FKM

322G7506

13

4270

486265

14

14

2.0

3522

15

60

3.6

3890

0.3

40

40

-10

100

NBR

322H75

124

2995

481865

2.0

3522

15

60

3.6

3890

0.3

40

40

-10

100

NBR

322H75

124

4270

481000

2.0

3522

15

60

3.6

3890

0.3

40

40

-10

100

NBR

322H75

124

4270

486265

14

14

2.0

3522

15

60

3.6

0.3

40

40

-10

100

FKM

322H7506

1234

2995

481865

2.0/14.1

3522

15

60

3.6

0.3

40

40

-10

120

FKM

322H7506

1234

4270

481000

2.0/14.1

3522

15

60

3.6

0.3

40

40

-10

140

FKM

322H7506

1234

4270

486265

14

14

2.0/14.1

3522

Notes:
1.Minimum pressure differential = 0.3 bar for opening and 0 bar for closing
2.Pilot seat disc in synthetic Ruby
3.Valve only compatible with hydraulic oil and neutral liquids
4.With 4 position selector for controlled closure rate

152

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

36

20

-10

-10

To

1/2''

15

60

40

140

50

Drawing 3523

Drawing 3522

153

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR HYDRAULIC OIL AND NEUTRAL


LIQUIDS (UP TO 100 BAR)
PILOT OPERATED

BRASS
SUB-BASE MOUNTING

NORMALLY CLOSED
Port
size

Orice

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
45 2.7
0.3 40 25 -10 100 FKM

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.

Housing
Ref.

Coil
Ref.

BSP

mm
14

1234

2995

SB

14

45

2.7

0.3

40

30

-10

120

FKM

E321F3202

1234

4270

14

45

2.7

0.3

40

40

-10

140

FKM

E321F3202

1234

4270

E321F3202

Power

Coil
Group

Dwg.
No.

481865

AC
W
8

DC
W
9

2.0

3520

481000

2.0

3520

486265

14

14

2.0

3520

Coil
Group

Dwg.
No.

Notes:
1.Minimum pressure differential = 0.3 bar for opening and 0 bar for closing
2.Pilot seat disc in synthetic Ruby
3.Valve only compatible with hydraulic oil and neutral liquids
4.With 4 position selector for controlled closure rate

BRASS
SUB-BASE MOUNTING

NORMALLY OPEN
Port
size

Orice

BSP

mm
14

SB

14

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
45 2.7
0.3 40 40
0 100 FKM

Parker LUCIFER
Valves

Flow
factors

45

2.7

0.3

40

40

120

FKM

Valve
Ref.

Power

Housing
Ref.

Coil
Ref.

322F7206

1234

2995

481865

AC
W
8

322F7206

1234

4270

481000

DC
W
9

2.1/14.1

3520

2.1/14.1

3520

Notes:
1.Minimum pressure differential = 0.3 bar for opening and 0 bar for closing
2.Pilot seat disc in synthetic Ruby
3.Valve only compatible with hydraulic oil and neutral liquids
4.With 4 position selector for controlled closure rate

154

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

14 mm

14

45

25

-10

-10

To

14 mm

14

45

40

140

50

Drawing 3520

155

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

156

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

HIGH CORROSION RESISTANT


VALVES (303 STAINLESS STEEL)

Oil

Actuation
Direct
Operated

Body
303 Stainless St./Pipe
mounting

Function
Normally Closed
Normally Open

Water

Air

2/2

Port
Size

Orice
(mm)

Flow
Factor
Kv(l/min)

MOPD
(bar)

Max
Fluid
Temp. (C)

Page

Page

Parker
Valves

Parker
LUCIFER
Valves

1/4''
1/4''

1.5 to 5
2.5

10
3

100
12

180
120

158
162

157

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

HIGH CORROSION RESISTANT VALVES


(303 STAINLESS STEEL)
DIRECT OPERATED

303 STAINLESS ST.


PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

1/4''

Orice

mm
1.5

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
Kv KV Qn
C
l/min m3/h m3/h bar bar bar C
1.5 0.09 80
0
20 20 -10 100 FKM

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.

Housing
Ref.

Coil
Ref.

IS

Power

Coil
Group

Dwg.
No.

8116

121V5406

2995

481865

AC
W
8

FKM

121V5406

4270

481000

2.0

8116

100 Ruby

121V5463

2995

481865

2.0

8116

30

130 Ruby

121V5463

4270

481000

2.0

8116

55

140 Ruby

121V5463

4270

486265

14

14

2.0

8116

-20

75

121V5497

2995

482740

1.6

3.0/6.0/8.0

8024

2.5

3.0/6.0/8.0

8024

3.0/6.0/8.0

8024

1.5

1.5 0.09

80

20

20

-10

1.5

1.5 0.09

80

60

25

1.5

1.5 0.09

80

75

1.5

1.5 0.09

80

100

1.5

1.5 0.09

80

120

PUR

1.5

1.5 0.09

80

10

10

-20

75

PUR

121V5497

495900

1.5

1.5 0.09

80

10

-20

75

PUR

121V5497

495910

DC
W
9

2.0

1.5

1.5 0.09

80

-20

75

PUR

121V5497

2995

496125

2
0.3
to 3
1.6

3.0/6.0/8.0

8024

2.5

3.5 0.21 220

14

-10

100

FKM

121V5706

2995

481865

2.0

8116

2.5

3.5 0.21 220

14

-10

120

FKM

121V5706

4270

481000

2.0

8116

2.5

3.5 0.21 220

14

14

-10

120

FKM

121V5706

4270

486265

14

14

2.0

8116

2.5

3.5 0.21 220

28

10

100 Ruby

121V5763

2995

481865

2.0

8116

2.5

3.5 0.21 220

34

12

130 Ruby

121V5763

4270

481000

2.0

8116

2.5

3.5 0.21 220

50

22

140 Ruby

121V5763

4270

486265

14

14

2.0

8116

4.5 0.27 315

10

-10

100

FKM

121V5306

2995

481865

2.0

8116

4.5 0.27 315

10

8.5

-10

120

FKM

121V5306

4270

481000

2.0

8116

4.5 0.27 315

10

10

-10

120

FKM

121V5306

4270

486265

14

14

2.0

8116

4.5 0.27 315

20

100 Ruby

121V5363

2995

481865

2.0

8116

4.5 0.27 315

25

8.5

130 Ruby

121V5363

4270

481000

2.0

8116

4.5 0.27 315

36

15

140 Ruby

121V5363

4270

486265

14

14

2.0

8116

Notes:
1.Valve only compatible with hydraulic oil and neutral liquids

158

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

1.5

1.5

-20

-20

To

1/4''

4.5

100

140

50

Drawing 8116

Drawing 8024

159

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

HIGH CORROSION RESISTANT VALVES


(303 STAINLESS STEEL)
DIRECT OPERATED

303 STAINLESS ST.


PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

1/4''

Orice

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h m3/h bar bar bar C
C
3.5 0.21 220 0
2
-20 75 PUR

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.

Housing
Ref.

IS

Coil
Ref.

Power

121V5397

2995

482740

AC
W
-

3.5 0.21 220

4.5

-20

75

PUR

121V5397

495900

2.5

3.5 0.21 220

4.5

-20

75

PUR

121V5397

495910

3.5 0.21 220

mm
3

Coil
Group

Dwg.
No.

3.0/6.0/8.0

8024

DC
W
1.6

3.0/6.0/8.0

8024

3.0/6.0/8.0

8024

-20

75

PUR

121V5397

2995

496125

2
0.3
to 3
1.6

3.0/6.0/8.0

8024

0.42 450

10

-10

100

FKM

121V5206

2995

481865

2.0

8116

0.42 450

10

-10

120

FKM

121V5206

4270

481000

2.0

8116

0.42 450

10

10

-10

120

FKM

121V5206

4270

486265

14

14

2.0

8116

0.42 450

3.5

3.5

100 PTFE

121V5212

2995

481865

2.0

8116

0.42 450

3.5

3.5

130 PTFE

121V5212

4270

481000

2.0

8116

0.42 450

3.5

3.5

130 PTFE

121V5212

4270

486265

14

14

2.0

8116

0.42 450

12

100 Ruby

121V5263

2995

481865

2.0

8116

0.42 450

15

130 Ruby

121V5263

4270

481000

2.0

8116

0.42 450

22

10

180 Ruby

121V5263

4270

486265

14

14

2.0

8116

10

0.6

750

-10

100

FKM

121V5106

2995

481865

2.0

8116

10

0.6

750

2.8

-10

120

FKM

121V5106

4270

481000

2.0

8116

10

0.6

750

-10

120

FKM

121V5106

4270

486265

14

14

2.0

8116

10

0.6

2.8

100 PTFE

121V5112

2995

481865

2.0

8116

10

0.6

2.8

2.8

130 PTFE

121V5112

4270

481000

2.0

8116

10

0.6

2.8

2.8

130 PTFE

121V5112

4270

486265

14

14

2.0

8116

10

0.6

750

8.5

100 Ruby

121V5163

2995

481865

2.0

8116

10

0.6

750

10

3.5

130 Ruby

121V5163

4270

481000

2.0

8116

10

0.6

750

14

6.5

140 Ruby

121V5163

4270

486265

14

14

2.0

8116

Notes:
1.Valve only compatible with hydraulic oil and neutral liquids

160

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

3.5

-20

-20

To

1/4''

10

22

180

50

Drawing 8024

Drawing 8116

161

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

HIGH CORROSION RESISTANT VALVES


(303 STAINLESS STEEL)
DIRECT OPERATED

303 STAINLESS ST.


PIPE MOUNTING

NORMALLY OPEN
Port
size

BSP
1/4''

Orice

mm
2.5
2.5

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
3 0.18 180 0
12 12 -30 100 FKM

Parker LUCIFER
Valves

Flow
factors

0.18 180

12

12

-30

120 Ruby

Valve
Ref.

Housing
Ref.

Coil
Ref.

122V8306

2995

122V8306

4270

162

Power

Coil
Group

Dwg.
No.

481865

AC
W
8

DC
W
9

2.1

8116

481000

2.1

8116

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

2.5

12

-30

-10

To

1/4''

2.5

12

120

50

Drawing 8116

163

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

164

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

HIGH CORROSION RESISTANT


VALVES (316L STAINLESS STEEL)

Oil

Actuation

Body

Function

Direct
Operated

316L Stainless St./Pipe Normally Closed


Mounting

Magnalift

316L Stainless St./Pipe Normally Closed


Mounting

Water

Air

2/2

Port
Size

Orice
(mm)

Flow
Factor
Kv(l/min)

MOPD
(bar)

Max
Fluid
Temp. (C)

Page

Page

Parker
Valves

Parker
LUCIFER
Valves

1/4''
1/8''
1/2''
3/8''
1/4''
1/2''
3/4''
3/8''
1''

1.5 to 3.5
1.5 to 2.5
5 to 6.2
5 to 6.2
1
15
24
15
24

2.3
2.3
13
13
0.6
50
95
40
105

20
20
4
4
98
10
10
10
10

140
140
140
140
75
140
140
140
140

166
166
168
168
172
172
172
174

170
-

165

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

HIGH CORROSION RESISTANT VALVES


(316L STAINLESS STEEL)
DIRECT OPERATED

316L STAINLESS ST.


PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

1/8''

1/4''

Orice

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv
KV
Qn
AC DC
l/min m3/h l/min bar bar bar C
C
1
0.06
0
20
-10 140 FKM

Parker
Valves

Flow
factors

Power

Valve
Ref.

Housing
Ref.

Coil
Ref.

Coil
Group

Dwg.
No.

074

201LG1GVG2

WB4.5

AC
W
4.5

1.5

0.06

10

-10

140

FKM

201LG1GVG2

WB5.0

1.1/1.3

074

1.8

0.11

15

-10

140

FKM

201LG1JVG2

WB4.5

4.5

1.1/1.3

074

mm
1.5

DC
W
-

1.1/1.3

1.8

0.11

-10

140

FKM

201LG1JVG2

WB5.0

1.1/1.3

074

2.5

2.3

0.14

10

-10

140

FKM

201LG1LVG2

WB4.5

4.5

1.1/1.3

074

2.5

2.3

0.14

-10

140

FKM

201LG1LVG2

WB5.0

1.1/1.3

074

1.5

0.06

20

-10

140

FKM

201LG2GVG2

WB4.5

4.5

1.1/1.3

075

1.5

0.06

10

-10

140

FKM

201LG2GVG2

WB5.0

1.1/1.3

075

1.8

0.11

15

-10

140

FKM

201LG2JVG2

WB4.5

4.5

1.1/1.3

075

1.8

0.11

-10

140

FKM

201LG2JVG2

WB5.0

1.1/1.3

075

2.5

2.3

0.14

10

-10

140

FKM

201LG2LVG2

WB4.5

4.5

1.1/1.3

075

2.5

2.3

0.14

-10

140

FKM

201LG2LVG2

WB5.0

1.1/1.3

075

0.5

0.027

-10

140

FKM

201LG2NVG7

481865

2.0

076

0.5

0.027

10

11

-10

140

FKM

201LG2NVG7

491514

13

16

2.0

076

3.5

0.6

0.036

-10

140

FKM

201LG2PVG7

481865

2.0

076

3.5

0.6

0.036

-10

140

FKM

201LG2PVG7

491514

13

16

2.0

076

166

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

1.5

0.5

-10

-10

To

1/4''

3.5

2.3

20

140

50

Drawing 074

Drawing 075

Drawing 076

167

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

HIGH CORROSION RESISTANT VALVES


(316L STAINLESS STEEL)
DIRECT OPERATED

316L STAINLESS ST.


PIPE MOUNTING

NORMALLY CLOSED
Port
size

Orice

BSP

mm
5

3/8''

1/2''

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv
KV
Qn
AC DC
l/min m3/h l/min bar bar bar C
C
11 0.66
0
3
3
-10 140 FKM

Parker
Valves

Flow
factors

11

0.66

-10

140

FKM

Valve
Ref.

Housing
Ref.

Power
Coil
Ref.

201LG3SVG7

481865

AC
W
8

201LG3SVG7

491514

13

Coil
Group

Dwg.
No.

DC
W
9

2.0

077

16

2.0

077

6.2

13

0.78

-10

140

FKM

201LG3UVG7

481865

2.0

077

6.2

13

0.78

-10

140

FKM

201LG3UVG7

491514

13

16

2.0

077

11

0.66

-10

140

FKM

201LG4SVG7

481865

2.0

078

11

0.66

-10

140

FKM

201LG4SVG7

491514

13

16

2.0

078

6.2

13

0.78

-10

140

FKM

201LG4UVG7

481865

2.0

078

6.2

13

0.78

-10

140

FKM

201LG4UVG7

491514

13

16

2.0

078

168

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/8''

11

-10

-10

To

1/2''

6.2

13

140

50

Drawing 077

Drawing 078

169

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

HIGH CORROSION RESISTANT VALVES


(316L STAINLESS STEEL)
DIRECT OPERATED

316L STAINLESS ST.


PIPE MOUNTING

NORMALLY CLOSED
Port
size

Orice

mm
1

1/4''
NPT

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h m3/h bar bar bar C
C
0.6 0.036 40
0
98 -40 75 PUR

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.
U121V5595

IS

Housing
Ref.

Coil
Ref.

Power

Coil
Group

Dwg.
No.

AC
W
-

DC
W
1.8

9.0/10.1

6713

0.3

9.0/10.1

6713

492210

0.6 0.036 40

98

-40

75

PUR

U121V5595

496565

0.6 0.036 40

98

98

-40

75

PUR

U121V5595

496800

9.0/10.1

6713

0.6 0.036 40

98

98

-40

75

PUR

U121V5595

496895

9.0/10.1

6713

0.6 0.036 40

98

98

-40

75

PUR

U121V5596

492310

10.1

6713

0.6 0.036 40

98

98

-40

75

PUR

U121V5596

496560

10.1

6713

0.6 0.036 40

98

98

-40

75

PUR

U121V5596

496800

10.1

6713

483270

11.0

6714

483270.02

11.0

6714

40

98

98

-10

75

PUR

U121V55961D

40

98

98

-10

75

FKM

U121V55961D

Notes:
Valve delivered with an individual material traceability certicate (3.1 following EN10204)

170

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

98

-40

-40

To

1/4''

0.6

98

75

50

Drawing 6713

Drawing 6714

171

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

HIGH CORROSION RESISTANT VALVES


(316L STAINLESS STEEL)
MAGNALIFT

316L STAINLESS ST.


PIPE MOUNTING

NORMALLY CLOSED
Port
size

Orice

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
Kv KV Qn
C
l/min m3/h l/min bar bar bar C
40 2.4
0
10
-10 85 EPDM

Parker
Valves

Flow
factors

Valve
Ref.

BSP

mm
15

3/8''

15

40

2.4

10

-10

140 EPDM

221S10E

15

40

2.4

10

-10

85

FKM

221S10F

1/2''

3/4''

221S10E

15

40

2.4

10

-10

85

FKM

221S10F

15

50

10

-10

85

EPDM

221S15E

15

50

10

-10

140 EPDM

221S15E

15

50

10

-10

85

FKM

221S15F

15

50

10

-10

85

FKM

221S15F

24

95

5.7

10

-10

85

EPDM

221S20E

24

95

5.7

10

-10

140 EPDM

221S20E

24

95

5.7

10

-10

85

FKM

221S20F

24

95

5.7

10

-10

85

FKM

221S20F

Power

Housing
Ref.

Coil
Ref.

2995
4270

Coil
Group

Dwg.
No.

067

481865

AC
W
8

DC
W
-

2.0

486265

14

14

2.0

067

2995

481865

2.0

067

4270

486265

14

14

2.0

067

2995

481865

2.0

068

4270

486265

14

14

2.0

068

2995

481865

2.0

068

4270

486265

14

14

2.0

068

2995

481865

2.0

069

4270

486265

14

14

2.0

069

2995

481865

2.0

069

4270

486265

14

14

2.0

069

Notes:
1.Maximum pressure for steam: 4 Bar (140C)

172

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/8''

15

40

-10

-10

To

3/4''

24

95

10

140

50

Drawing 067

Drawing 068

Drawing 069

173

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

HIGH CORROSION RESISTANT VALVES


(316L STAINLESS STEEL)
MAGNALIFT

316L STAINLESS ST.


PIPE MOUNTING

NORMALLY CLOSED
Port
size

Orice

Parker
Valves

Flow
factors

BSP

mm
24

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
105 6.3
0
10
-10 85 EPDM

221S25E

2995

1''

24

105

6.3

10

-10

140 EPDM

221S25E

4270

24

105

6.3

10

-10

85

FKM

221S25F

24

105

6.3

10

-10

85

FKM

221S25F

Valve
Ref.

Power

Housing
Ref.

Coil
Ref.

Coil
Group

Dwg.
No.

070

481865

AC
W
8

DC
W
-

2.0

486265

14

14

2.0

070

2995

481865

2.0

070

4270

486265

14

14

2.0

070

Notes:
1.Maximum pressure for steam: 4 Bar (140C)

174

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1''

24

105

-10

-10

To

1''

24

105

10

140

50

Drawing 070

175

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

176

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

OIL BURNER VALVES

Oil Burner

Actuation
Direct
Operated

Magnalift
Pilot
Operated
Pilot
Operated

Body

Function

2/2

Port
Size

Orice
(mm)

Flow
Factor
Kv(l/min)

MOPD
(bar)

Max
Fluid
Temp. (C)

Page

Page

Parker
Valves

Parker
LUCIFER
Valves

1/8''
1/4''
3/8''
1/2''
1/8''
1/4''

1.7 to 4
2.5 to 4
5 to 11
5 to 14
2.5 to 3
2.5 to 3

5.3
6.5
22
25
4
4

30
30
30
30
30
30

160
160
160
160
160
160

178
180
182
182
186
186

184
184
184
184
188
188

Brass/Pipe mounting

Normally Closed

Brass/Pipe mounting

Normally Open

Brass/Sub-base
mounting
Brass/Pipe mounting
Brass/Pipe mounting

Normally Closed

14 mm

14

25

30

160

188

Normally Closed
Normally Closed

1/2''
1/4''
3/8''
1/2''

15
8
11
15

50
36
50
60

5
40
40
40

140
140
160
160

190
192
192
194

14 mm

14

45

30

160

194

Brass/Sub-base
mounting

Normally Closed

177

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

OIL BURNER VALVES


DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port Orice
size

BSP

1/8''

Flow
factors

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Valve Order
Min Max(MOPD) Min Max
Number
Kv KV Qn
AC DC
l/min m3/h m3/h bar bar bar C C
1.4 0.086 0
25
-10 90 NBR 390034 2

Power

Parker Valves
Valve
Type

Coil
Type

Dwg.
No.

131IN

KT09 110-120/60

AC
W
9

22.0

015

1.7

1.4 0.086

25

-10

90

NBR

390085 2

131IN

KT09 208-230/60

22.0

015

1.7

1.4 0.086

25

-10

90

NBR

390005 2

131IN

KT09 24/50

22.0

015

1.7

1.4 0.086

22

-10

90

NBR

390120 2

131IN

KT10 24 DC

10

22.0

015

1.7

1.4 0.086

25

-10

90

NBR

390300 12

131INDIN

XT09 230/50

22.0

015

1.7

1.4 0.086

25

-10

90

FKM

390086 2

131IV

KT09 208-230/60

22.0

015

1.7

1.4 0.086

25

-10

90

FKM

390088 12

131IV

KT09 230/50

22.0

015

1.7

1.4 0.086

25

-10

90

FKM

390089 2

131IV

KT09 240/50

22.0

015

mm
1.7

DC
W
-

Coil
Group

2.2

0.12

15

-10

90

NBR

390216 2

131AN

KT09 208-230/60

22.0

015

2.2

0.12

15

-10

90

NBR

390165 2

131AN

KT09 230/50

22.0

015

2.2

0.12

15

-10

90

NBR

390145 2

131AN

KT09 24/50

22.0

015

2.2

0.12

15

-10

90

NBR

390150 2

131AN

KT09 42/50

22.0

015

2.2

0.12

13

-10

90

NBR

390195 2

131AN

KT10 12 DC

10

22.0

015

0.12

13

-10

90

NBR

390215 2

131AN

KT10 24 DC

10

22.0

015

2.5

3.2 0.192

30

-30

140 Ruby

362496J

PM140IR

ZB09

20.1/20.2

027

2.5

3.2 0.192

17

-30

140 Ruby

362496J

PM140IR

ZB12

12

20.1/20.2

027

2.8

2.9 0.174

-10

140

FKM

390445 2

131.4BV

KT09 115/50

22.0

012

2.8

2.9 0.174

-10

140

FKM

390457 2

131.4BV

KT09 115/60

22.0

012

2.8

2.9 0.174

-10

140

FKM

390458 2

131.4BV

KT09 208-230/60

22.0

012

2.8

2.9 0.174

-10

140

FKM

390465 2

131.4BV

KT09 230/50

22.0

012

2.8

2.9 0.174

-10

140

FKM

390405 2

131.4BV

KT09 24/50

22.0

012

2.8

2.9 0.174

-10

140

FKM

390495 2

131.4BV

KT10 12 DC

10

22.0

012

2.8

2.9 0.174

-10

140

FKM

390505 2

131.4BV

KT10 24 DC

10

22.0

012

2.2

Notes:
1.DIN-EN-ISO 23553-1 (2009-10) approved for oil burners
2.Ordering number is for an assembled valve and coil, with the voltage shown.

178

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

1.7

1.4

-30

-10

To

1/8''

2.8

3.2

30

140

50

Drawing 015

Drawing 027

Drawing 012

179

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

OIL BURNER VALVES


DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port Orice
size

BSP

1/8''

1/4''

Flow
factors

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Valve Order
Min Max(MOPD) Min Max
Number
Kv KV Qn
AC DC
l/min m3/h m3/h bar bar bar C C
4 0.24 0
30
-30 140 Ruby 362510J 1

Power

Parker Valves
Valve
Type

Coil
Type

Dwg.
No.

PM140.4AR

ZH14

AC
W
14

20.2

025

5.3 0.318

-10

90

NBR

390874 2

131.4CG

KT09 115/50

22.0

013

5.3 0.318

-10

90

NBR

390813 2

131.4CG

KT09 115/60

22.0

013

5.3 0.318

-10

90

NBR

390878 2

131.4CG

KT09 230/50

22.0

013

5.3 0.318

-10

90

NBR

390805 2

131.4CG

KT09 24/50

22.0

013

5.3 0.318

-10

90

NBR

390875 2

131.4CG

KT09 240/50

22.0

013

5.3 0.318

-10

90

NBR

390803 2

131.4CG

KT10 12DC

10

22.0

013

5.3 0.318

-10

90

NBR

390802 2

131.4CG

KT10 24 DC

10

22.0

013

2.5

3.2 0.192

30

-30

140 Ruby

362518J 1

PM140CR

ZB09

20.1/20.2

026

2.5

3.2 0.192

17

-30

140 Ruby

362518J 1

PM140CR

ZB12

12

20.1/20.2

026

2.5

3.2 0.192

30

-30

140 Ruby

362518J 1

PM140CR

ZH14

14

20.1/20.2

026

2.5

3.2 0.192

17

-30

140 Ruby

362518J 1

PM140CR

ZH16

16

20.1/20.2

026

2.8

2.9 0.174

-10

140

FKM

390560 2

131.4FV

KT09 115/50

22.0

014

2.8

2.9 0.174

-10

140

FKM

390560 2

131.4FV

KT09 115/60

22.0

014

2.8

2.9 0.174

-10

140

FKM

390626 2

131.4FV

KT09 208-230/60

22.0

014

2.8

2.9 0.174

-10

140

FKM

390580 2

131.4FV

KT09 230/50

22.0

014

2.8

2.9 0.174

-10

140

FKM

390525 2

131.4FV

KT09 24/50

22.0

014

2.8

2.9 0.174

-10

140

FKM

390605 2

131.4FV

KT10 12 DC

10

22.0

014

2.8

2.9 0.174

-10

140

FKM

390625 2

131.4FV

KT10 24 DC

10

22.0

014
026

mm
3

DC
W
-

Coil
Group

0.24

30

-30

140 Ruby

362530J 1

PM140.4DR

ZH14

14

20.2

0.24

30

-30

140 Ruby

362524J

PM140DR

ZB09

20.1/20.2

026

0.24

12

-30

140 Ruby

362524J

PM140DR

ZB12

12

20.1/20.2

026

0.24

30

-30

140 Ruby

362524J

PM140DR

ZH14

14

20.1/20.2

026

0.24

12

-30

140 Ruby

362524J

PM140DR

ZH16

16

20.1/20.2

026

5.3 0.318

-10

90

NBR

390915 2

131.4GG

KT09 115/50

22.0

013

5.3 0.318

-10

90

NBR

390945 2

131.4GG

KT09 230/50

22.0

013

5.3 0.318

-10

90

NBR

390895 2

131.4GG

KT09 24/50

22.0

013

5.3 0.318

-10

90

NBR

390975 2

131.4GG

KT09 240/50

22.0

013

5.3 0.318

-10

90

NBR

390995 2

131.4GG

KT10 12 DC

10

22.0

013

5.3 0.318

-10

90

NBR

390997 2

131.4GG

KT10 24 DC

10

22.0

013

5.3 0.318

-10

140

FKM

390668 2

131.4GV

KT09 115/50

22.0

014

5.3 0.318

-10

140

FKM

390700 2

131.4GV

KT09 115/60

22.0

014

5.3 0.318

-10

140

FKM

390725 2

131.4GV

KT09 208-230/60

22.0

014

Notes:
1.DIN-EN-ISO 23553-1 (2009-10) approved for oil burners
2.Ordering number is for an assembled valve and coil, with the voltage shown.

180

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

2.5

2.9

-30

-10

To

1/4''

5.3

30

140

50

Drawing 025

Drawing 013

Drawing 026

Drawing 014

181

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

OIL BURNER VALVES


DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port Orice
size

BSP

1/4''

3/8''
1/2''

Flow
factors

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Valve Order
Min Max(MOPD) Min Max
Number
Kv KV Qn
AC DC
l/min m3/h m3/h bar bar bar C C
5.3 0.318 0
2
-10 140 FKM 390705 2

Power

Parker Valves
Valve
Type

Coil
Type

Dwg.
No.

131.4GV

KT09 230/50

AC
W
9

22.0

014

5.3 0.318

-10

140

FKM

390650 2

131.4GV

KT09 24/50

22.0

014

5.3 0.318

-10

140

FKM

390718 2

131.4GV

KT09 240/50

22.0

014

5.3 0.318

-10

140

FKM

390720 2

131.4GV

KT10 12 DC

10

22.0

014

5.3 0.318

-10

140

FKM

390721 2

131.4GV

KT10 24 DC

10

22.0

014

10 0.612

-10

140

FKM

364010

PM153BV

ZB14

14

20.2/22.0

037

10 0.612

1.5

-10

140

FKM

364010

PM153BV

ZB16

16

20.2/22.0

037

10 0.612

-10

140

FKM

364035

PM153GV

ZB14

14

20.2/22.0

037

10 0.612

1.5

-10

140

FKM

364035

PM153GV

ZB16

16

20.2/22.0

037

mm
4

DC
W
-

Coil
Group

Notes:
1.DIN-EN-ISO 23553-1 (2009-10) approved for oil burners
2.Ordering number is for an assembled valve and coil, with the voltage shown.

182

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

5.3

-10

-10

To

1/2''

10

140

50

Drawing 014

Drawing 037

183

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

OIL BURNER VALVES


DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP
1/8''
1/4''
3/8''
1/2''

Orice

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
4 0.24 0
30
-30 160 Ruby

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

Dwg.
No.

13

8520.23

483824

AC
W
19

14.1

3292

4.5 0.27

30

-30

160 Ruby

121K6423

13

8520.23

483824

19

14.1

3292

6.5 0.39

30

160 Ruby

121K6220

13

8520.23

483541

20

14.1

3510

12

0.72

120 Ruby

121K3321

2995

492425

14

14

14.1

3551

mm
3

121K2423

DC
W
-

Coil
Group

11

22

1.32

30

160

FKM

121G2320

123

8520.23

483541

20

14.1

3646

14

25

1.5

30

160

FKM

121G2520

123

8520.23

483541

20

14.1

3646

14

25

1.5

30

160

FKM

121G2523

123

8520.23

483824

19

14.1

3646

Notes:
1.DIN-EN-ISO 23553-1 (2009-10) approved for oil burners
2.Max. Static pressure = 30 bar; max pressure differential = 0.2 bar
3.Valve only compatible with hydraulic oil and neutral liquids

Drawing 3646

184

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

-30

To

1/2''

14

25

30

160

60

Drawing 3292

Drawing 3510

Drawing 3551

185

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

OIL BURNER VALVES


DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY OPEN
Port Orice
size

BSP
1/8''
1/4''

Flow
factors

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h m3/h bar bar bar C C
4 0.24 0
30
-30 160 Ruby

Power

Parker Valves
Valve Order
Number

Valve
Type

Coil
Type

Dwg.
No.

360451J

PM120.4IR

ZB14

AC
W
14

20.2

001

0.24

30

-30

160 Ruby

360451J 1

PM120.4IR

ZH14

14

20.2

001

0.24

30

-30

160 Ruby

360452J

PM120.4AR

ZB14

14

20.2

001

0.24

30

-30

160 Ruby

360452J 1

PM120.4AR

ZH14

14

20.2

001

mm
3

DC
W
-

Coil
Group

Notes:
1.DIN-EN-ISO 23553-1 (2009-10) approved for oil burners

186

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

30

-30

-10

To

1/4''

30

160

50

Drawing 001

187

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

OIL BURNER VALVES


DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY OPEN
Port
size

BSP

Orice

1/8''

mm
2.5

1/4''

2.5

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
3.5 0.21 0
30
-30 160 Ruby

Parker LUCIFER
Valves

Flow
factors

3.5 0.21

30

-30

160 Ruby

Valve
Ref.
122K9321
122K8321

Housing
Ref.

Coil
Ref.

12

8520.23

12

8520.23

Power

Coil
Group

Dwg.
No.

483824

AC
W
19

DC
W
-

14.1

6766

483824

19

14.1

6766

Coil
Group

Dwg.
No.

14.1

7638

Notes:
1.DIN-EN-ISO 23553-1 (2009-10) approved for oil burners
2.Valve only compatible with hydraulic oil and neutral liquids

BRASS
SUB-BASE MOUNTING

NORMALLY CLOSED
Port
size

SB

Orice

mm
14

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
25 1.5
0
30
0 160 FKM

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.
121F2523

12

Housing
Ref.

Coil
Ref.

8520.23

483824

Power

AC
W
19

DC
W
-

Notes:
1.DIN-EN-ISO 23553-1 (2009-10) approved for oil burners
2.Valve only compatible with hydraulic oil and neutral liquids

188

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

2.5

3.5

30

-30

To

14 mm

14

25

30

160

60

Drawing 6766

Drawing 7638

189

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

OIL BURNER VALVES


MAGNALIFT

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

Orice

BSP

mm

1/2''

15

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
Kv KV Qn
C
l/min m3/h l/min bar bar bar C

Parker LUCIFER
Valves

Flow
factors

50

140

FKM

Valve
Ref.
221G2523

Housing
Ref.

Coil
Ref.

8520.23

483824

Power

AC
W

DC
W

19

Coil
Group

Dwg.
No.

14.1

8298

Notes:
1.DIN-EN-ISO 23553-1 (2009-10) approved for oil burners

190

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/2''

15

50

To

1/2''

15

50

140

60

Drawing 8298

191

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

OIL BURNER VALVES


PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

Orice

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
AC DC
Kv KV Qn
C
l/min m3/h l/min bar bar bar C
36 2.16 0.3 40 25 -10 100 FKM

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.

Housing
Ref.

BSP

mm
8

E321H21

234

2995

1/4''

36

2.16

0.3

40

30

-10

120

FKM

E321H21

234

4270

36

2.16

0.3

40

40

-10

140

FKM

E321H21

234

11

40

2.4

0.3

30

3/8''

160 Ruby

11

50

0.3

40

25

-10

100

FKM

E321H23

50

0.3

40

30

-10

120

FKM

E321H23

11

50

0.3

40

40

-10

140

FKM

E321H23

Coil
Group

Dwg.
No.

481865

AC
W
8

DC
W
9

2.0

3523

481000

2.0

3523

4270

486265

14

14

2.0

3523

8520.23

483541

20

14.1

3633

234

2995

481865

2.0

3521

234

4270

481000

2.0

3521

234

4270

486265

14

14

2.0

3521

321H2322

11

Coil
Ref.

Power

124

Notes:
1.DIN-EN-ISO 23553-1 (2009-10) approved for oil burners
2.Minimum pressure differential = 0.3 bar for opening and 0 bar for closing
3.Pilot seat disc in synthetic Ruby
4.Valve only compatible with hydraulic oil and neutral liquids

192

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

36

25

-10

-10

To

3/8''

11

50

40

160

50

Drawing 3523

Drawing 3633

Drawing 3521

193

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

OIL BURNER VALVES


PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

1/2''

Orice

mm
15

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
60 3.6
0.3 30
0 160 Ruby

Parker LUCIFER
Valves

Flow
factors

15

60

3.6

0.3

30

15

60

3.6

0.3

40

25

15

60

3.6

0.3

40

15

60

3.6

0.3

40

Valve
Ref.
321H2522

Housing
Ref.

Coil
Ref.

14

8520.23

14

8520.23

Power

Coil
Group

Dwg.
No.

3633

483541

AC
W
20

DC
W
-

14.1

483824

19

14.1

3633

2995

481865

2.0/14.2

3522

160 Ruby

321H2523

-10

100

FKM

E321H25

234

30

-10

120

FKM

E321H25

234

483371

2.0/14.2

3522

40

-10

140

FKM

E321H25

234

4270

486265

14

14

2.0/14.2

3522

Coil
Group

Dwg.
No.

14.1

7639

Notes:
1.DIN-EN-ISO 23553-1 (2009-10) approved for oil burners
2.Minimum pressure differential = 0.3 bar for opening and 0 bar for closing
3.Pilot seat disc in synthetic Ruby
4.Valve only compatible with hydraulic oil and neutral liquids

BRASS
SUB-BASE MOUNTING

NORMALLY CLOSED
Port
size

SB

Orice

mm
14

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
3
l/min m /h l/min bar bar bar C
C
45 2.7
0
30
0 160 FKM

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.
321F2523

123

Housing
Ref.

Coil
Ref.

8520.23

483824

Power

AC
W
19

DC
W
-

Notes:
1.DIN-EN-ISO 23553-1 (2009-10) approved for oil burners
2.Minimum pressure differential = 0.3 bar for opening and 0 bar for closing
3.Valve only compatible with hydraulic oil and neutral liquids

194

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/2''

14

45

25

-10

-10

To

14 mm

15

60

40

160

50

Drawing 3633

Drawing 3522

Drawing 7639

195

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

196

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

FAST SWITCHING VALVES

Air

Actuation
Magnalift

Body
Brass/Pipe mounting

Function
Normally Closed

2/2

Port
Size

Orice
(mm)

Flow
Factor
Kv(l/min)

MOPD
(bar)

Max
Fluid
Temp. (C)

Page

Page

Parker
Valves

Parker
LUCIFER
Valves

3/8''

40

198

197

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

FAST SWITCHING VALVES


MAGNALIFT

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

BSP

Orice

mm

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

AC
W

DC
W

Coil
Group

Dwg.
No.

40

PUR

221J3301E

2995.6

483816

14

8020

40

PUR

221J3301E

4270

486265

14

8020

3/8''

Notes:
1.For more details, please consult catalogue 8674UK

198

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/8''

To

3/8''

40

50

Drawing 8020

199

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

200

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

VALVES FOR BEVERAGE


DISPENSING - LIQUIPURE

2/2

100

Steam

Actuation

Body

Direct Operated Stainless St./Sub-base

Function
Normally Closed

mounting

201

Water

Port
Size

Orice
(mm)

Flow
Factor
Kv(l/min)

MOPD
(bar)

Max
Fluid
Temp. (C)

Parker
Valves

Page

SB

1.5 to 3

4.2

20

202

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR BEVERAGE DISPENSING LIQUIPURE


DIRECT OPERATED

STAINLESS ST.
SUB-BASE MOUNTING

NORMALLY CLOSED
Port
size

Orice

Power

Valve
Ref.

Housing
Ref.

Coil
Ref.

DC
W
16

Coil
Group

Dwg.
No.

2019F1GRG7

D4

AC
W
13

24.0

071

1.5

1.3

0.08

20

20

-10

140

Ruby

2019F1GRG7

D5

24.0

071

1.5

1.3

0.08

20

20

-10

140

Ruby

2019F1GRG7

LA

24.0

071

1.5

1.3

0.08

20

20

-10

140

Ruby

2019F1GRG7

LB-LC

13

16

24.0

071

1.5

1.3

0.08

20

-10

140

Ruby

2019F1GRG7

XS03

24.0

071

1.5

1.3

0.08

20

20

-10

140

FDA FKM

2019F1GVG7

D4

13

16

24.0

071

1.5

1.3

0.08

20

20

-10

140

FDA FKM

2019F1GVG7

D5

24.0

071

1.5

1.3

0.08

20

20

-10

140

FDA FKM

2019F1GVG7

LA

24.0

071

1.5

1.3

0.08

20

20

-10

140

FDA FKM

2019F1GVG7

LB-LC

13

16

24.0

071

1.5

1.3

0.08

20

-10

140

FDA FKM

2019F1GVG7

XS03

24.0

071

2.3

0.14

15

15

-10

140

Ruby

2019F1JRG7

D4

13

16

24.0

071
071

mm
1.5

SB

Operating
Fluid
Seat Seal
Pressure
Temp.
Differential
Min Max(MOPD) Min Max
Qn
AC DC
Kv
KV
C
l/min m3/h l/min bar bar bar C
1.3 0.08
0
20 20 -10 140
Ruby

Parker
Valves

Flow
factors

2.3

0.14

15

15

-10

140

Ruby

2019F1JRG7

D5

24.0

2.3

0.14

15

15

-10

140

Ruby

2019F1JRG7

LA

24.0

071

2.3

0.14

15

15

-10

140

Ruby

2019F1JRG7

LB-LC

13

16

24.0

071

2.3

0.14

15

-10

140

Ruby

2019F1JRG7

XS03

24.0

071

2.3

0.14

15

15

-10

140

FDA FKM

2019F1JVG7

D4

13

16

24.0

071
071

2.3

0.14

15

15

-10

140

FDA FKM

2019F1JVG7

D5

24.0

2.3

0.14

15

15

-10

140

FDA FKM

2019F1JVG7

LA

24.0

071

2.3

0.14

15

15

-10

140

FDA FKM

2019F1JVG7

LB-LC

13

16

24.0

071

2.3

0.14

15

-10

140

FDA FKM

2019F1JVG7

XS03

24.0

071

2.5

3.2

0.19

10

10

-10

140

Ruby

2019F1LRG7

D4

13

16

24.0

071

2.5

3.2

0.19

10

10

-10

140

Ruby

2019F1LRG7

D5

24.0

071

2.5

3.2

0.19

10

10

-10

140

Ruby

2019F1LRG7

LA

24.0

071

2.5

3.2

0.19

10

10

-10

140

Ruby

2019F1LRG7

LB-LC

13

16

24.0

071

202

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

SB

1.5

1.3

10

-10

-10

To

SB

2.5

3.2

20

140

50

Drawing 071

203

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES

2/2

VALVES FOR BEVERAGE DISPENSING LIQUIPURE


DIRECT OPERATED

STAINLESS ST.
SUB-BASE MOUNTING

NORMALLY CLOSED
Port
size

Orice

mm
2.5
2.5

SB

Operating
Fluid
Seat Seal
Pressure
Temp.
Differential
Min Max(MOPD) Min Max
Kv
KV
Qn
AC DC
l/min m3/h l/min bar bar bar C
C
3.2 0.19
0
10
-10 140
Ruby

Parker
Valves

Flow
factors

3.2

0.19

10

10

-10

140

FDA FKM

Power

Valve
Ref.

Housing
Ref.

Coil
Ref.

2019F1LRG7

2019F1LVG7

Coil
Group

Dwg.
No.

XS03

AC
W
9

DC
W
-

24.0

071

D4

13

16

24.0

071
071

2.5

3.2

0.19

10

10

-10

140

FDA FKM

2019F1LVG7

D5

24.0

2.5

3.2

0.19

10

10

-10

140

FDA FKM

2019F1LVG7

LA

24.0

071

2.5

3.2

0.19

10

10

-10

140

FDA FKM

2019F1LVG7

LB-LC

13

16

24.0

071

2.5

3.2

0.19

10

-10

140

FDA FKM

2019F1LVG7

XS03

24.0

071

4.2

0.25

-10

140

Ruby

2019F1NRG7

D4

13

16

24.0

071
071

4.2

0.25

-10

140

Ruby

2019F1NRG7

D5

24.0

4.2

0.25

-10

140

Ruby

2019F1NRG7

LA

24.0

071

4.2

0.25

-10

140

Ruby

2019F1NRG7

LB-LC

13

16

24.0

071

4.2

0.25

-10

140

Ruby

2019F1NRG7

XS03

24.0

071

4.2

0.25

-10

140

FDA FKM

2019F1NVG7

D4

13

16

24.0

071
071

4.2

0.25

-10

140

FDA FKM

2019F1NVG7

D5

24.0

4.2

0.25

-10

140

FDA FKM

2019F1NVG7

LA

24.0

071

4.2

0.25

-10

140

FDA FKM

2019F1NVG7

LB-LC

13

16

24.0

071

4.2

0.25

-10

140

FDA FKM

2019F1NVG7

XS03

24.0

071

204

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

SB

2.5

3.2

-10

-10

To

SB

4.2

10

140

50

Drawing 071

205

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

206

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

VALVES FOR DRY OR LUBRICATED


AIR, NEUTRAL GASES AND LIQUIDS

Oil

Actuation
Direct
Operated

Body
Brass/Pipe mounting

Pilot
Operated

Flow
Factor
Kv(l/min)

MOPD
(bar)

Max
Fluid
Temp. (C)

Page

Page

Parker
Valves

Parker
LUCIFER
Valves

1/8''
1/8''-1/4''
1/4''
1/4''
1/8''
1/4''
1/4''
SB
3.5 mm
5 mm
5 mm
1/8''-1/5''
5 mm

1.2 to 2.5
2.5
1 to 4.5
1.5 to 3
1.5 to 2.5
0.8 to 3.5
1.5
1.3
1.2 to 1.5
1 to 2.5
1.5 to 2.5
1.5
1.5 to 2.5

3.5
3.5
7
4.5
3.5
5
1.5
1
0.9
3.5
2.2
1.5
3.5

20
7
30
16
10
30
16
20
10
16
15
10
10

140
75
140
120
140
140
100
140
75
120
120
120
120

208
208
220
220
226
-

Normally Closed

1/8''

1.2

10

50

234

Normally Closed

5 mm

1.5

1.5

15

100

236

Normally Closed

3 mm

10

50

238

Normally Closed

1/4''
1/2''
1/4''
1/2''

6.5 to 8
14
8
14

20
20
-

15
15
40
15

75
75
75
100

240
242
242
244

1/2''

15

10

75

244

Normally Closed

Control by Electric Impulse


Normally Closed

Normally Open
Anodized aluminium/
Sub-base mounting/
Poppet

3/2

Orice
(mm)

Normally Open
Universal
Anodized aluminium/
Banjo
303 Stainless St./Subbase mounting
POM/Sub-base
mounting
Anodized aluminium/
Pipe mounting

Air

Port
Size

Function

Normally Open
Universal

Brass/Sub-base
mounting

Water

210
218

224
228
228
230
232
232

Normally Closed

207

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

3/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

Orice

BSP

1/8''

1/4''

(2)
mm

Flow
factors
1

(2)

Kv
l/min

Operating
Pressure
Differential

Fluid
Temp.

Seat
Seal

(2) Min Max(MOPD) Min Max

KV
l/min

bar

AC
bar

DC
bar

Power

Parker Valves
Valve Order
Number

Valve
Type

Coil
Type

AC
W

DC
W

Coil
Group

Dwg.
No.

1.2

1.6

0.7

0.04

-10

140

FKM

398102 1

N79.4IV

WB4.5 115/50-60

4.5

1.3

066

1.2

1.6

0.7

0.04

14

-10

140

FKM

398104 1

N79.4IV

WB4.5 230/50-60

4.5

1.3

066

1.2

1.6

0.7

0.04

14

-10

140

FKM

398120 1

N79.4IV

WB4.5 24/50-60

4.5

1.3

066

1.2

1.6

0.7

0.04

14

-10

140

FKM

398100 1

N79.4IV

WB4.5 42/50-60

4.5

1.3

066

1.2

1.6

0.7

0.04

14

-10

140

FKM

398108 1

N79.6IV

WB4.5 115/50-60

4.5

1.3

080

1.2

1.6

0.7

0.04

14

-10

140

FKM

398110 1

N79.6IV

WB4.5 230/50-60

4.5

1.3

080

1.2

1.6

0.7

0.04

14

-10

140

FKM

398152 1

N79.6IV

WB4.5 24/50-60

4.5

1.3

080

1.5

1.6

0.06

-10

140

FKM

398112 1

N79.4AV WB4.5 230/50-60

4.5

1.3

066

1.5

1.6

0.06

-10

140

FKM

398122 1

N79.4AV

WB4.5 24/50-60

4.5

1.3

066

1.5

1.6

0.06

-10

140

FKM

398138 1

N79.6AV WB4.5 115/50-60

4.5

1.3

080

1.5

1.6

0.06

-10

140

FKM

398130U 1

N79.6AV

4.5

1.3

080

1.5

1.6

0.06

-10

140

FKM

398114 1

N79.6AV WB4.5 230/50-60

4.5

1.3

080

1.5

1.6

0.06

-10

140

FKM

398142 1

N79.6AV WB4.5 240/50-60

4.5

1.3

080

1.5

1.5

1.2

0.07

20

-10

140

FKM

362560J

PM141AV

ZB09

1.6

1.5

0.09

-10

140

FKM

398134U 1

N79.6BV

WB4.5 115/60

4.5

1.3

080

1.6

1.5

0.09

-10

140

FKM

398136U 1

N79.6BV WB4.5 208-240/60 4.5

1.3

080

1.6

1.5

0.09

-10

140

FKM

398132 1

N79.6BV WB4.5 230/50-60

4.5

1.3

080

2.5

0.12

15

-10

140

FKM

362570J

PM141BV

ZB09

20.1/20.2 029

2.5

0.12

15

-10

140

FKM

362620J

PM141FV

ZB09

20.1/20.2 033

2.5

2.5

2.8

0.17

-10

140

FKM

362630J

PM141GV

ZB09

20.1/20.2 033

WB4.5 115/60

20.1/20.2 029

Notes:
1.Ordering number is for an assembled valve and coil, with the voltage shown.

208

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

1.2

0.7

-10

-10

To

1/4''

2.5

2.8

20

140

50

Drawing 066

Drawing 080

Drawing 029

Drawing 033

209

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

3/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

Orice

BSP

1/8''

(2)

Flow
factors
1

(2)

Kv
l/min

mm

(2)

KV
l/min

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

IS

Power

AC
W

DC
W

Coil
Group

Dwg.
No.

3382

1.2

1.5

0.7

0.9 0.042 0.054

10

10

-10

75

FKM

131M15

8993

488980

2.5

1.1

1.5

1.5

0.9

0.9 0.054 0.054

-10

75

FKM

131M14

8993

488980

2.5

1.1

3382

1.5

1.5

1.5

1.5 0.09 0.09

15

15

-10

120

FKM

E131K14

4270

481000

2.1

3510

1.5

1.5

1.5

1.5 0.09 0.09

15

15

-10

100

FKM

E131K14

2995

481865

2.1

3510

2.5

2.5

3.5 0.15 0.21

10

10

-10

120

FKM

131K16

4270

481000

2.1

3510

2.5

2.5

3.5 0.15 0.21

10

10

-10

100

FKM

131K16

2995

481865

2.1

3510

2.5

2.5

3.5 0.15 0.21

10

10

-10

120

FKM

131K1650 1

4270

481000

2.1

3510

2.5

2.5

3.5 0.15 0.21

10

10

-10

100

FKM

131K1650 1

2995

481865

2.1

3510

2.5

2.5

3.5

3.5 0.21 0.21

-10

120

FKM

E131K13

4270

481000

2.0

3510

2.5

2.5

3.5

3.5 0.21 0.21

-10

100

FKM

E131K13

2995

481865

2.0

3510

2.5

2.5

3.5

3.5 0.21 0.21

-10

100

FKM

E131K13

4270

486265

14

14

2.0

3510

2.5

2.5

0.18 0.18

-20

75

PUR

131K0397

2995

482740

1.6

6.0/8.0

8023

2.5
1/8''- 2.5
1/4''
2.5

2.5

0.18 0.18

-20

75

PUR

131K0397

495900

2.5

6.0/8.0

8023

2
0.3
to 3
8
9
0.5
to 3
0.3
to 3
0.3
to 3

1/4''

2.5

0.18 0.18

-20

75

PUR

131K0397

495910

2.5

3.5

3.5 0.21 0.21

-40

75

PUR

E131K0358 1

4270

481000

2.5

2.5

3.5

3.5 0.21 0.21

-40

75

PUR

E131K0358 1

2995

481865

0.6

0.6 0.036 0.036

10

-10

55

FKM

131K0490

2995

483580.01 *

0.6

0.6 0.036 0.036

10

-10

75

FKM

131K0490

488660.01 *

0.6

- 0.036 -

10

-10

75

FKM

131K0490

495910

6.0/8.0

8023

2.1

3510

2.1

3510

7.0

7058

7.0

7058

7.0

7058

Notes:
1.With manual override

Drawing 7058

210

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

0.6

-40

-40

To

1/4''

2.5

3.5

15

120

50

Drawing 3382

Drawing 3510

Drawing 8023

211

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

3/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

Orice

BSP

1/4''

(2)

Flow
factors
1

(2)

Kv
l/min

mm

(2)

KV
l/min

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

IS

Coil
Ref.

Power

AC
W

Coil
Group

Dwg.
No.

DC
W

1.2

1.5

0.8

1.5 0.048 0.09

30

-30

130 Ruby

E131K64

4270

481000

2.0

3510

1.2

1.5

0.8

1.5 0.048 0.09

30

30

-30

140 Ruby

E131K64

4270

486265

14

14

2.0

3510

1.2

1.5

0.8

1.5 0.048 0.09

30

-30

130 Ruby

E131K6450 1

4270

481000

2.0

3510

1.2

1.5

0.8

1.5 0.048 0.09

30

30

-30

140 Ruby

E131K6450 1

4270

486265

14

14

2.0

3510

1.5

1.5

1.5

1.5 0.09 0.09

-20

75

PUR

131K0497

2995

482740

1.6

6.0/8.0

8023

1.5

1.5

1.5

1.5 0.09 0.09

-20

75

PUR

131K0497

495900

2.5

8023

1.5

1.5

1.5 0.09 0.09

-20

75

PUR

131K0497

495910

6.0/8.0

8023

1.5

1.5

1.5

1.5 0.09 0.09

-20

75

PUR

131K0497

2995

496125

2
0.3
to 3
1.6

6.0/8.0

1.5

6.0/8.0

8023

1.5

1.5

1.5

1.5 0.09 0.09

16

16

-10

120

FKM

E131K04

4270

481000

2.0

3510

1.5

1.5

1.5

1.5 0.09 0.09

16

16

-10

100

FKM

E131K04

2995

481865

2.0

3510

1.5

1.5

1.5

1.5 0.09 0.09

16

16

-10

120

FKM

E131K04

4270

486265

14

14

2.0

3510

1.5

1.5

1.5

1.5 0.09 0.09

15

15

-10

120

FKM

E131K0450 1

4270

481000

2.1

3510

1.5

1.5

1.5

1.5 0.09 0.09

15

15

-10

100

FKM

E131K0450 1

2995

481865

2.1

3510

2.5

4.5 0.15 0.27

10

10

-10

75

FKM

131T23

4270

481000

2.0

3223

2.5

4.5 0.15 0.27

10

10

-10

75

FKM

131T23

2995

481865

2.0

3223

2.5

4.5 0.15 0.27

10

10

-10

75

FKM

131T23

4270

486265

14

14

2.0

3223

2.5

4.5 0.15 0.27

10

10

-10

75

FKM

131T2301 1

4270

481000

2.0

3223

2.5

4.5 0.15 0.27

10

10

-10

75

FKM

131T2301 1

2995

481865

2.0

3223

2.5

4.5 0.15 0.27

10

10

-10

75

FKM

131T2301 1

4270

486265

14

14

2.0

3223

Notes:
1.With manual override

212

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

1.2

0.8

-30

-20

To

1/4''

2.5

30

140

50

Drawing 3510

Drawing 8023

Drawing 3223

213

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

3/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

Orice

BSP

1/4''

(2)
mm

Flow
factors
1

(2)

Kv
l/min

(2)

KV
l/min

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

IS

Power

AC
W

Coil
Group

Dwg.
No.

DC
W

2.5

2.5

3.5 0.15 0.21

10

10

-10

120

FKM

E131K06

4270

481000

2.0

8119

2.5

2.5

3.5 0.15 0.21

10

10

-10

100

FKM

E131K06

2995

481865

2.0

8119

2.5

2.5

3.5 0.15 0.21

10

10

-10

120

FKM

E131K06

4270

486265

14

14

2.0

8119

2.5

2.5

3.5 0.15 0.21

10

10

-10

120

FKM

E131K0650 1

4270

481000

2.1

3510

2.5

2.5

3.5 0.15 0.21

10

10

-10

100

FKM

E131K0650 1

2995

481865

2.1

3510

2.5

2.5

-20

75

PUR

131K0397

2995

496125

1.6

6.0/8.0

8023
3223

0.18 0.18

2.5

3.5

3.5

5.5 0.21 0.33

-10

75

FKM

131T29

4270

481000

2.1

2.5

3.5

3.5

5.5 0.21 0.33

-10

75

FKM

131T29

2995

481865

2.1

3223

2.5

3.5

3.5

5.5 0.21 0.33

-10

75

FKM

131T2901 1

4270

481000

2.1

3223

2.5

3.5

3.5

5.5 0.21 0.33

-10

75

FKM

131T2901 1

2995

481865

2.1

3223

Notes:
1.With manual override

Drawing 3223

214

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

2.5

-20

-20

To

1/4''

2.5

3.5

10

120

50

Drawing 8119

Drawing 3510

Drawing 8023

215

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

3/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

Orice

BSP

1/4''

(2)

Flow
factors
1

(2)

Kv
l/min

mm

(2)

KV
l/min

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

IS

Power

AC
W

Coil
Group

Dwg.
No.

DC
W

2.5

2.7

15 0.162 0.9

0.1

-10

75

FKM

E131E03

4270

481000

2.0

3525

2.5

2.7

15 0.162 0.9

0.1

-10

75

FKM

E131E03

2995

481865

2.0

3525

2.5

2.7

15 0.162 0.9

0.1

-10

75

FKM

E131E03

4270

486265

14

14

2.0

3525

2.5

2.5

3.5

3.5 0.21 0.21

-10

100

FKM

E131K03

4270

481000

2.0

3510
3510

2.5

2.5

3.5

3.5 0.21 0.21

-10

100

FKM

E131K03

2995

481865

2.0

2.5

2.5

3.5

3.5 0.21 0.21

-40

75

PUR

E131K0308

4270

481000

2.1

3510

2.5

2.5

3.5

3.5 0.21 0.21

-40

75

PUR

E131K0308

2995

481865

2.1

3510

2.5

2.5

3.5

3.5 0.21 0.21

-10

120

FKM

E131K0350 1

4270

481000

2.1

3510

2.5

2.5

3.5

3.5 0.21 0.21

-10

100

FKM

E131K0350 1

2995

481865

2.1

3510

2.5

2.5

3.5

3.5 0.21 0.21

-30

130 Ruby

E131K63

4270

481000

2.0

3510

2.5

2.5

3.5

3.5 0.21 0.21

-30

100 Ruby

E131K63

2995

481865

2.0

3510

2.5

2.5

3.5

3.5 0.21 0.21

-30

130 Ruby

E131K6350 1

4270

481000

2.1

3510

2.5

2.5

3.5

3.5 0.21 0.21

-30

100 Ruby

E131K6350 1

2995

481865

2.1

3510

4.5

0.27 0.36

10

-10

75

FKM

131T22

4270

481044

14

2.2

3223

4.5

0.27 0.36

10

-10

75

FKM

131T22

2995

492425

14

2.2

3223

4.5

0.42 0.54

-10

75

FKM

131T21

4270

481000

2.0

3223

4.5

0.42 0.54

-10

75

FKM

131T21

2995

481865

2.0

3223

4.5

0.42 0.54

-10

75

FKM

131T21

4270

486265

14

14

2.0

3223

Notes:
1.With manual override

216

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

2.5

2.7

-40

-40

To

1/4''

4.5

10

130

50

Drawing 3525

Drawing 3510

Drawing 3223

217

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

3/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY OPEN
Port
size

Orice

BSP

1/4''

(2)

Flow
factors
1

(2)

Kv
l/min

mm

(2)

KV
l/min

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

AC
W

DC
W

Coil
Group

Dwg.
No.

1.5

1.5

1.4

1.4 0.084 0.084

16

16

-10

120

FKM

132K04

4270

481000

2.1

3510

1.5

1.5

1.4

1.4 0.084 0.084

16

16

-10

100

FKM

132K04

2995

481865

2.1

3510

1.8

1.8 0.108 0.108

10

10

-10

120

FKM

132K06

4270

481000

2.1

3510

1.8

1.8 0.108 0.108

10

10

-10

100

FKM

132K06

2995

481865

2.1

3510

2.5

4.5 0.15 0.27

10

-10

75

FKM

132T23

4270

481000

2.0

3223

2.5

4.5 0.15 0.27

10

-10

75

FKM

132T23

2995

481865

2.0

3223

2.5

4.5 0.15 0.27

10

-10

75

FKM

132T23

4270

486265

14

2.0

3223

2.5

4.5 0.15 0.27

10

-10

75

FKM

132T2301 1

4270

481000

2.0

3223

2.5

4.5 0.15 0.27

10

-10

75

FKM

132T2301 1

2995

481865

2.0

3223

2.5

4.5 0.15 0.27

10

-10

75

FKM

132T2301 1

4270

486265

14

2.0

3223

2.5

2.5

2.2

2.2 0.132 0.132

-10

120

FKM

132K03

4270

481000

2.1

3510

2.5

2.5

2.2

2.2 0.132 0.132

-10

100

FKM

132K03

2995

481865

2.1

3510

4.5

0.27 0.36

10

-10

75

FKM

132T22

4270

481044

14

2.2

3223

4.5

0.27 0.36

-10

75

FKM

132T22

2995

492425

14

2.2

3223

Notes:
1.With manual override

218

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

1.5

1.4

-10

-30

To

1/4''

4.5

16

120

50

Drawing 3510

Drawing 3223

219

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

3/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
PIPE MOUNTING

UNIVERSAL
Port
size

Orice

BSP
1/8''

1/4''

(2)

Flow
factors
1

(2)

Kv
l/min

mm

Operating
Pressure
Differential

(2)
KV
l/min

Fluid
Temp.

Seat
Seal

Min Max(MOPD) Min Max


bar

AC
bar

DC
bar

Power

Parker Valves
Valve Order
Number

Valve
Type

Coil
Type

AC
W

Coil
Group

Dwg.
No.

DC
W

1.5

1.5

1.2

0.07

10

-10

140

FKM

362410J

PM139AV

ZB09

20.1/20.2

022

1.5

1.5

1.2

0.07

10

-10

140

FKM

362410J

PM139AV

ZB12

12

20.1/20.2

022

0.12

-10

140

FKM

362460J

PM139FV

ZB09

20.1/20.2

022

0.12

-10

140

FKM

362460J

PM139FV

ZB12

12

20.1/20.2

022

2.5

2.5

2.8

0.17

-10

140

FKM

362470J

PM139GV

ZB09

20.1/20.2

022

2.5

2.5

2.8

0.17

-10

140

FKM

362470J

PM139GV

ZB12

12

20.1/20.2

022

3.5

2.5

0.3

-10

140

FKM

362475J

PM139LV

ZB09

20.1/20.2

022

3.5

2.5

0.3

-10

140

FKM

362475J

PM139LV

ZB12

12

20.1/20.2

022

220

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

1.5

1.2

-10

-10

To

1/4''

3.5

10

140

50

Drawing 022

221

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

3/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
PIPE MOUNTING

UNIVERSAL
Port
size

1.5

1.5

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
1 (2) 1 (2) Min Max (MOPD) Min Max
Kv
KV
AC DC
l/min
m3/h
bar bar bar C
C
1.5 1.5 0.09 0.09 0
10
10 -10 100 FKM

E133K14

2995

481865

AC
W
8

2.1

3510

1.5

1.5

1.5

1.5 0.09 0.09

10

10

-10

120

FKM

E133K14

4270

481000

2.1

3510

2.5

2.5 0.15 0.15

-10

100

FKM

E133K16

2995

481865

2.1

3510

2.5

-10

120

FKM

E133K16

4270

481000

2.1

3510

2.5

2.5

3.5

3.5 0.21 0.21

-10

100

FKM

E133K13

2995

481865

2.1

3510

2.5

2.5

3.5

3.5 0.21 0.21

-10

120

FKM

E133K13

4270

481000

2.1

3510

Orice

BSP

1/8''

1/4''

(2)
mm

Parker LUCIFER
Valves

Flow
factors

0.15

Valve
Ref.

Housing
Ref.

Coil
Ref.

IS

Power

DC
W
9

Coil
Group

Dwg.
No.

0.8

0.8

0.3

0.3 0.018 0.018

30

30

-10

100

FKM

E133K05

2995

481865

2.1

3510

0.8

0.8

0.3

0.3 0.018 0.018

30

30

-10

120

FKM

E133K05

4270

481000

2.1

3510

0.8

0.8

0.3

0.3 0.018 0.018

30

30

-10

120

FKM

E133K05

4270

486265

14

14

2.0

3510

1.5

1.5

1.5

1.5 0.09 0.09

-20

75

PUR

133K0497

2995

482740

1.6

6.0/8.0

8023

1.5

1.5

1.5

1.5 0.09 0.09

-20

75

PUR

133K0497

495900

2.5

8023

1.5

1.5

1.5 0.09 0.09

-20

75

PUR

133K0497

495910

6.0/8.0

8023

1.5

1.5

1.5

1.5 0.09 0.09

-20

75

PUR

133K0497

2995

496125

2
0.3
to 3
1.6

6.0/8.0

1.5

6.0/8.0

8023

1.5

1.5

1.5

1.5 0.09 0.09

10

10

-10

100

FKM

E133K04

2995

481865

2.0

3510

1.5

1.5

1.5

1.5 0.09 0.09

10

10

-10

120

FKM

E133K04

4270

481000

2.0

3510

1.5

1.5

1.5

1.5 0.09 0.09

10

10

-10

120

FKM

E133K04

4270

486265

14

14

2.0

3510

1.5

1.5

1.5

1.5 0.09 0.09

10

10

-10

100

FKM

E133K0450 1

2995

481865

2.1

3510

1.5

1.5

1.5

1.5 0.09 0.09

10

10

-10

120

FKM

E133K0450 1

4270

481000

2.1

3510

2.5

2.5 0.15 0.15

-10

75

FKM

133T23

2995

481865

2.1

3223

2.5

2.5 0.15 0.15

-10

75

FKM

133T23

4270

481000

2.1

3223

2.5

2.5 0.15 0.15

-10

75

FKM

133T2301 1

2995

481865

2.1

3223

2.5

2.5 0.15 0.15

-10

75

FKM

133T2301 1

4270

481000

2.1

3223

2.5

2.5 0.15 0.15

-10

100

FKM

E133K06

2995

481865

2.0/3.0

3510

2.5

2.5 0.15 0.15

-10

120

FKM

E133K06

4270

481000

2.0/3.0

3510

2.5

2.5 0.15 0.15

-10

120

FKM

E133K06

4270

486265

14

14

2.0/3.0

3510

2.5

2.5 0.15 0.15

-10

100

FKM

E133K0650 1

2995

481865

2.1

3510

2.5

2.5 0.15 0.15

-10

120

FKM

E133K0650 1

4270

481000

2.1

3510

2.5

2.5

3.5

3.5 0.21 0.21

-10

100

FKM

E133K03

2995

481865

2.0

3510

2.5

2.5

3.5

3.5 0.21 0.21

-10

120

FKM

E133K03

4270

481000

2.0

3510

2.5

2.5

3.5

3.5 0.21 0.21

-10

120

FKM

E133K03

4270

486265

14

14

2.0

3510

2.5

2.5

3.5

3.5 0.21 0.21

-10

100

FKM

E133K0350 1

2995

481865

2.1

3510

2.5

2.5

3.5

3.5 0.21 0.21

-10

120

FKM

E133K0350 1

4270

481000

2.1

3510

4.5

4.5 0.27 0.27

-10

75

FKM

133T21

2995

481865

2.1

3223

4.5

4.5 0.27 0.27

-10

75

FKM

133T21

4270

481000

2.1

3223

Notes:
1.With manual override

222

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

0.8

0.3

-20

-20

To

1/4''

4.5

30

120

50

Drawing 3510

Drawing 8023

Drawing 3223

223

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

3/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
PIPE MOUNTING

UNIVERSAL
Port
size

Orice

BSP
1/4''

(2)

Flow
factors
1

(2)

Kv
l/min

mm

(2)

KV
m3/h

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

IS

Power

AC
W

Coil
Group

Dwg.
No.

DC
W

4.5

4.5 0.27 0.27

-10

75

FKM

133T2101 1

2995

481865

2.1

3223

4.5

4.5 0.27 0.27

-10

75

FKM

133T2101 1

4270

481000

2.1

3223

Coil
Group

Dwg.
No.

4.0

8104

Notes:
1.With manual override

BRASS
PIPE MOUNTING

CONTROL BY ELECTRIC IMPULSE


Port
size

Orice

BSP
1/4''

(2)
mm

1.5

1.5

Flow
factors
1

(2)

Kv
l/min
1.5

(2)

KV
l min
/

1.5 0.09 0.09

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C
0

16

-10

100

FKM

224

Parker LUCIFER
Valves
Valve
Ref.
135K04

Housing
Ref.

Coil
Ref.

4269

485400

Power

AC
W

DC
W

13

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

1.5

1.5

-10

-10

To

1/4''

4.5

16

100

50

Drawing 3223

Drawing 8104

225

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

3/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
SUB-BASE MOUNTING

NORMALLY CLOSED
Port
size

Orice

(2)
mm

SB

Flow
factors
1

(2)

Kv
l/min

Operating
Pressure
Differential

(2)
KV
l/min

Fluid
Temp.

Seat
Seal

Min Max(MOPD) Min Max


bar

AC
bar

DC
bar

Power

Parker Valves
Valve Order
Number

Valve
Type

Coil
Type

AC
W

DC
W

Coil
Group

Dwg.
No.

1.3

2.5

0.06

20

10

-30

140 Ruby

360490J 1

PM128GR

ZB09

20.1/20.2

009

1.3

2.5

0.06

20

10

-30

140 Ruby

360480J 1

PM128IR

YB09

20.1/20.2

010

1.3

2.5

0.06

20

10

-30

140 Ruby

360480J 1

PM128IR

ZB09

20.1/20.2

010

1.3

2.5

0.06

20

10

-10

140

FKM

360506 1

PM128ISV

ZB09

20.1/20.2

010

1.3

2.5

0.06

20

10

-10

140

FKM

360479J 1

PM128IV

ZB09

20.1/20.2

010

Notes:
1.Maximum static pressure: 14.5 Bar (for Viton sealing, maximum static pressure: 12 Bar)

226

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

SB

1.3

10

-30

-10

To

SB

1.3

20

140

50

Drawing 009

Drawing 010

227

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

3/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
SUB-BASE MOUNTING

NORMALLY CLOSED
Port
size

1.2

1.5

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
1 (2) 1 (2) Min Max (MOPD) Min Max
Kv
KV
AC DC
l/min
l/min
bar bar bar C
C
0.7 0.9 0.042 0.054 0
10
10 -10 75 FKM

1.2

1.5

0.7

Orice

(2)
mm

SB

SB

Flow
factors

0.9 0.042 0.054

10

10

-10

75

FKM

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

131M75

8993

131M7550 1

8993

IS

Coil
Ref.

Power

Coil
Group

Dwg.
No.

488980

AC
W
2

DC
W
2.5

1.1

3383

488980

2.5

1.1

3383

1.5

1.5

0.9

0.9 0.054 0.054

-10

75

FKM

131M74

8993

488980

2.5

1.1

3383

1.5

1.5

0.9

0.9 0.054 0.054

-10

75

FKM

131M7450 1

8993

488980

1.1

3383

0.6

0.6 0.036 0.036

10

-10

75

FKM

131F4490

2995

483580.01 *

7.0

7057

0.6

0.6 0.036 0.036

10

-10

75

FKM

131F4490

488660.01 *

7.0

7057

0.6

0.6 0.036 0.036

10

-10

75

FKM

131F4490

495910

7.0

7057

1.5

1.5

2.2 0.09 0.132

16

-10

100

FKM

131F4410

2995

481865

2.5
0.5
to 3
0.3
to 3
0.3
to 3
9

2.1

3509

1.5

1.5

1.5

1.5 0.09 0.09

-20

75

PUR

131F4497

2995

482740

1.6

6.0/8.0

8022

1.5

1.5

1.5

1.5 0.09 0.09

-20

75

PUR

131F4497

495900

2.5

8022

1.5

1.5

1.5 0.09 0.09

-20

75

PUR

131F4497

495910

6.0/8.0

8022

1.5

1.5

1.5

1.5 0.09 0.09

-20

75

PUR

131F4497

2995

496125

2
0.3
to 3
1.6

6.0/8.0

1.5

6.0/8.0

8022

Notes:
1.With manual override

Drawing 8022

228

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3.5 mm

0.6

-20

-20

To

5 mm

1.5

1.5

16

100

50

Drawing 3383

Drawing 7057

Drawing 3509

229

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

3/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
SUB-BASE MOUNTING

NORMALLY CLOSED
Port
size

Orice

(2)

(2)

Kv
l/min

mm

SB

Flow
factors
1

(2)

KV
l/min

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C

Parker LUCIFER
Valves
Valve
Ref.

IS

Housing
Ref.

Coil
Ref.

Power

AC
W

DC
W

Coil
Group

Dwg.
No.

3509

1.5

1.5

1.5

1.5 0.09 0.09

15

15

-10

100

FKM

E131F44

2995

481865

2.1

1.5

1.5

1.5

1.5 0.09 0.09

15

15

-10

120

FKM

E131F44

4270

481000

2.1

3509

1.5

1.5

1.5

1.5 0.09 0.09

15

15

-10

100

FKM

E131F4450 1

2995

481865

2.1

3509

1.5

1.5

1.5

1.5 0.09 0.09

15

15

-10

100

FKM

E131F4450 1

4270

481000

2.1

3509

2.5

2.5

3.5 0.15 0.21

10

10

-10

100

FKM

131F46

2995

481865

2.1

3509

2.5

2.5

3.5 0.15 0.21

10

10

-10

120

FKM

131F46

4270

481000

2.1

3509

2.5

2.5

3.5 0.15 0.21

10

10

-10

100

FKM

131F4650 1

2995

481865

2.1

3509

2.5

2.5

3.5 0.15 0.21

10

10

-10

120

FKM

131F4650 1

4270

481000

2.1

3509

2.5

2.5

3.5

3.5 0.21 0.21

-10

100

FKM

E131F43

2995

481865

2.1

3509

2.5

2.5

3.5

3.5 0.21 0.21

-10

120

FKM

E131F43

4270

481000

2.1

3509

2.5

2.5

3.5

3.5 0.21 0.21

-10

100

FKM

E131F4350 1

2995

481865

2.0

3509

2.5

2.5

3.5

3.5 0.21 0.21

-10

120

FKM

E131F4350 1

4270

481000

2.0

3509

2.5

2.5

3.5

3.5 0.21 0.21

-10

100

FKM

E131F4350 1

4270

486265

14

14

2.0

3509

Coil
Group

Dwg.
No.

Notes:
1.With manual override

BRASS
SUB-BASE MOUNTING

NORMALLY OPEN
Port
size

Orice

(2)

(2)

Kv
l/min

mm

SB

Flow
factors
1

(2)
KV
l/min

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

AC
W

DC
W

1.5

1.5

1.4

1.4 0.084 0.084

15

15

-10

75

FKM

132F44

4270

481000

2.1

3509

1.5

1.5

1.4

1.4 0.084 0.084

15

15

-10

75

FKM

132F44

2995

481865

2.1

3509

1.8

1.8 0.108 0.108

10

10

-10

120

FKM

132F46

4270

481000

2.1

3509

1.8

1.8 0.108 0.108

10

10

-10

100

FKM

132F46

2995

481865

2.1

3509

2.5

2.5

2.2

2.2 0.132 0.132

-10

75

FKM

132F43

4270

481000

2.0

3509

2.5

2.5

2.2

2.2 0.132 0.132

-10

75

FKM

132F43

2995

481865

2.0

3509

2.5

2.5

2.2

2.2 0.132 0.132

-10

75

FKM

132F43

4270

486265

14

14

2.0

3509

230

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

5 mm

1.5

1.4

-10

-30

To

5 mm

2.5

3.5

15

120

50

Drawing 3509

231

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

3/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

BRASS
SUB-BASE MOUNTING

UNIVERSAL
Port
size

Orice

(2)

SB

(2)

Kv
l/min

mm
SB

Flow
factors
1

(2)

KV
l/min

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

AC
W

DC
W

Coil
Group

Dwg.
No.

1.5

1.5

1.5

1.5 0.09 0.09

10

10

-10

100

FKM

E133F4450 1

4270

481000

2.1

3509

1.5

1.5

1.5

1.5 0.09 0.09

10

10

-10

120

FKM

E133F4450 1

2995

481865

2.1

3509

1.5

1.5

1.5

1.5 0.09 0.09

10

10

-10

120

FKM

E133F44

4270

481000

2.1

3509

1.5

1.5

1.5

1.5 0.09 0.09

10

10

-10

100

FKM

E133F44

2995

481865

2.1

3509

2.5

2.5 0.15 0.15

-10

120

FKM

133F46

4270

481000

2.1

3509

2.5

2.5 0.15 0.15

-10

100

FKM

133F46

2995

481865

2.1

3509

2.5

2.5

3.5

3.5 0.21 0.21

-10

120

FKM

E133F43

4270

481000

2.1

3509

2.5

2.5

3.5

3.5 0.21 0.21

-10

100

FKM

E133F43

2995

481865

2.1

3509

Notes:
1.With manual override

232

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''-1/5''

1.5

1.5

-10

-10

To

5 mm

2.5

3.5

10

120

50

Drawing 3509

233

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

3/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

ANODIZED ALUMINIUM
BANJO

NORMALLY CLOSED
Port Orice
size

Flow
factor

1
BSP

1/8''

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C
0
10
10 -10 50 NBR

Parker LUCIFER
Valves
Valve
Ref.

Housing Ref.

mm
1.2

Qn
l/min
50

131B04 12

1.2

50

10

10

-10

50

NBR

131B04 12

1.2

50

10

10

-10

50

NBR

131B04 12

1.2

50

10

10

-10

50

NBR

1.2

50

10

10

-10

50

1.2

50

10

10

-10

50

Power
Coil
Ref.

Coil
Group

Dwg.
No.

496131

AC
W
3

DC
W
3

1.2

8226

496482

1.2

8226

496637

1.2

8226

131B14 12

496131

1.2

8227

NBR

131B14 12

496482

1.2

8227

NBR

131B14 12

496637

1.2

8227

Notes:
1.Valve only compatible with air and neutral gases
2.With manual override

234

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

1.2

50

10

-10

-10

To

1/8''

1.2

50

10

50

50

Drawing 8226

Drawing 8227

235

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

3/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

303 STAINLESS ST.


SUB-BASE MOUNTING

NORMALLY CLOSED
Port
size

Orice

BSP
SB

(2)
mm

1.5

1.5

Flow
factors
1

(2)

Kv
l/min
1.5

(2)
KV
l/min

2.2 0.09 0.132

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C
0

15

15

-10

100

NBR

236

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

131F5406

2995

481865

Power

AC
W

DC
W

Coil
Group

Dwg.
No.

2.1

3509

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

5 mm

1.5

1.5

15

-10

-10

To

5 mm

1.5

1.5

15

100

50

Drawing 3509

237

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

3/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
DIRECT OPERATED

POM
SUB-BASE MOUNTING

NORMALLY CLOSED
Port
size

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
1 (2) 1 (2) Min Max (MOPD) Min Max
Kv
KV
AC DC
l/min
l/min
bar bar bar C
C
2
2 0.12 0.12 0
10
10 -10 50 FKM

Orice

(2)
mm

SB

Parker LUCIFER
Valves

Flow
factors

0.12 0.12

10

10

-10

50

FKM

Valve
Ref.

Housing
Ref.

Coil
Ref.

E131F26 12

2995

E131F26 2

2995

Power

Coil
Group

Dwg.
No.

481865

AC
W
8

DC
W
9

2.1/3.0

3601

482730

2.1/3.0

3601

Notes:
1.20% Switch-on - max. 2 min
2.With manual override

238

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3 mm

10

-10

-10

To

3 mm

10

50

50

Drawing 3601

239

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

3/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
PILOT OPERATED

ANODIZED ALUMINIUM
PIPE MOUNTING

NORMALLY CLOSED
Port
size

Orice

Parker LUCIFER
Valves

(2)

Kv
l/min

Valve
Ref.

Housing
Ref.

IS

Coil
Ref.

Power

Dwg.
No.

6.5

6.5

10

0.6

10

-10

55

NBR

331B7490 1

2995

483580.01 *

6.5

6.5

10

0.6

10

-10

75

NBR

331B7490 1

488660.01 *

6.5

6.5

10

0.6

10

-10

75

NBR

331B7490 1

495910

6.5

10

0.6

10

10

-10

75

NBR

E331B74 13

2995

481865

6.5

10

0.6

10

10

-10

75

NBR

E331B74 13

4270

485100

2.1

3240

20

20 1.2 1.2

15

15

-10

75

FKM

E331B01 2

4270

481000

2.1

3234

20

20 1.2 1.2

15

15

-10

75

FKM

E331B01 2

2995

481865

2.1

3234

20

20 1.2 1.2

15

15

-10

75

FKM

E331B01 2

483371

2.1

3234

mm

AC
W

Coil
Group

DC
W
0.5
to 3
0.3
to 3
0.3
to 3
9

BSP

1/4''

(2)

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
1 (2) Min Max (MOPD) Min Max
KV
AC DC
l/min
bar bar bar C
C

Flow
factors

7.0/8.0

8270

7.0/8.0

8270

7.0/8.0

8270

2.1

3240

Notes:
1.Valve only compatible with air and neutral gases
2.Valve only compatible with hydraulic oil and air/neutral gases
3.With manual override

240

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

6.5

10

10

-10

-10

To

1/4''

20

15

75

50

Drawing 8270

Drawing 3240

Drawing 3234

241

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

3/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
PILOT OPERATED

ANODIZED ALUMINIUM
PIPE MOUNTING

NORMALLY CLOSED
Port
size

14

14

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
1 (2) Min Max (MOPD) Min Max
KV
AC DC
l/min
bar bar bar C
C
1
15
-10 75 FKM

14

14

Orice

BSP
1/2''

(2)

Parker LUCIFER
Valves

Flow
factors
1

(2)

Kv
l/min

mm

15

15

-10

75

FKM

Valve
Ref.

Housing
Ref.

E331B21 1

2995

E331B21 1

IS

Coil
Ref.

Power

Coil
Group

Dwg.
No.

482722

AC
W
10

DC
W
-

2.1

3238

483371

2.1

3238

Coil
Group

Dwg.
No.

Notes:
1.Valve only compatible with air and neutral gases
2.Valve only compatible with hydraulic oil and air/neutral gases
3.With manual override

ANODIZED ALUMINIUM
PIPE MOUNTING

NORMALLY OPEN
Port
size

10

10

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
1 (2) Min Max (MOPD) Min Max
KV
AC DC
l/min
bar bar bar C
C
0.6 0.6 1
40
40 -10 75 PCTFE

332B02 13

2995

481865

AC
W
8

2.1

8114

10

10

0.6

0.6

40

40

-10

75 PCTFE

332B02 13

4270

481000

2.1

8114

20

20

1.2

1.2

15

15

-10

75

FKM

E332B01 3

2995

481865

2.1

3234

20

20

1.2

1.2

15

15

-10

75

FKM

E332B01 3

4270

481000

2.1

3234

20

20

1.2

1.2

15

15

-10

75

FKM

E332B01 3

483371

2.1

3234

Orice

BSP

1/4''

(2)

(2)

Kv
l/min

mm

Parker LUCIFER
Valves

Flow
factors

Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

DC
W
9

Notes:
1.Pilot seat discs in Kel-F (PCTFE); valve with pilot return pipe
2.Valve only compatible with air and neutral gases
3.Valve only compatible with hydraulic oil and air/neutral gases

242

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

10

15

-10

-10

To

1/2''

14

20

40

75

50

Drawing 3238

Drawing 8114

Drawing 3234

243

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

3/2

VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL


GASES AND LIQUIDS
PILOT OPERATED

ANODIZED ALUMINIUM
PIPE MOUNTING

NORMALLY OPEN
Port
size

Orice

BSP
1/2''

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C

Flow
factors

(2)

(2)

Kv
l/min

mm

(2)

KV
l/min

Parker LUCIFER
Valves

Power

Valve
Ref.

Housing
Ref.

Coil
Ref.

AC
W

DC
W

Coil
Group

Dwg.
No.

14

14

15

15

-10

100

FKM

E332B21 2

2995

481865

2.1

3238

14

14

15

15

-10

100

FKM

E332B21 2

4270

481000

2.1

3238

Notes:
1.Pilot seat discs in Kel-F (PCTFE); valve with pilot return pipe
2.Valve only compatible with air and neutral gases
3.Valve only compatible with hydraulic oil and air/neutral gases

ANODIZED ALUMINIUM
SUB-BASE MOUNTING

NORMALLY CLOSED

mm
15

Qn
l/min
5000

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C
0.5 10
10 -10 75 FKM

E331L21 1

2995

15

5000

0.5

E331L21 1

Port Orice
size

Flow
factor

SB

10

10

-10

75

FKM

Parker LUCIFER
Valves
Valve
Ref.

Housing Ref.

Power
Coil
Ref.

Coil
Group

Dwg.
No.

481865

AC
W
8

DC
W
9

2.1/3.0

3130

483371

2.1/3.0

3130

Notes:
1.With manual override

244

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/2''

14

10

-10

-10

To

1/2''

15

5000

15

100

50

Drawing 3238

Drawing 3130

245

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

246

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

VALVES FOR HYDRAULIC OIL AND


NEUTRAL LIQUIDS (UP TO 75 BAR)

Oil

Actuation
Pilot
Operated

Body
Anodized aluminium/
Pipe mounting

Function
Normally Closed

Water

3/2

Port
Size

Orice
(mm)

Flow
Factor
Kv(l/min)

MOPD
(bar)

Max
Fluid
Temp. (C)

Page

Page

Parker
Valves

Parker
LUCIFER
Valves

1/4''

10

40

75

248

247

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

3/2

VALVES FOR HYDRAULIC OIL AND


NEUTRAL LIQUIDS (UP TO 75 BAR)
PILOT OPERATED

ANODIZED ALUMINIUM
PIPE MOUNTING

NORMALLY CLOSED
Port
size

Orice

BSP
1/4''

(2)

Flow
factors
1

(2)

Kv
l/min

mm

(2)
KV
m3/h

10

10

0.6

0.6

10

10

0.6

0.6

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C
1
40
40 -10 75 NBR
1

40

40

-10

75

NBR

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

331B02 1

2995

331B02 1

4270

Power

Coil
Group

Dwg.
No.

481865

AC
W
8

DC
W
9

2.1

8114

481000

2.1

8114

Notes:
1.Pilot seat discs in Kel-F (PCTFE); valve with pilot return pipe

248

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

10

40

-10

-10

To

1/4''

10

40

75

50

Drawing 8114

249

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

250

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

HIGH CORROSION RESISTANT


VALVES (303 STAINLESS STEEL)

Oil

Actuation
Direct
Operated

Body
303 Stainless St./Pipe
mounting

Function
Normally Closed
Universal

Water

Air

3/2

Port
Size

Orice
(mm)

Flow
Factor
Kv(l/min)

MOPD
(bar)

Max
Fluid
Temp. (C)

Page

Page

Parker
Valves

Parker
LUCIFER
Valves

1/4''
1/4''
1/4''

1 to 2.5
1 to 2.5
1.5 to 2.5

3.5
3.5
3.5

15
15
10

180
180
180

252
252
254

251

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

3/2

HIGH CORROSION RESISTANT VALVES


(303 STAINLESS STEEL)
DIRECT OPERATED

303 STAINLESS ST.


PIPE MOUNTING

NORMALLY CLOSED
Port
size

Orice

(2)

Kv
l/min

(2)
KV
m3/h

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C

Parker LUCIFER
Valves

IS

Coil
Ref.

Power

Valve
Ref.

Housing
Ref.

FKM

131V5490

2995

483580.01 *

488660.01 *

Dwg.
No.

7.0

6740

7.0

6740

0.6

0.6

0.6 0.036 0.036

10

-10

75

FKM

131V5490

0.6

0.6 0.036 0.036

10

-10

75

FKM

131V5490

495910

1.5

1.5

1.5

1.5 0.09 0.09

15

15

-10

120 FKM

131V5406

4270

481000

2.1

8116

1.5

1.5

1.5

1.5 0.09 0.09

15

15

-10

100 FKM

131V5406

2995

481865

2.1

8116

1.5

1.5

1.5

1.5 0.09 0.09

15

15

130 Ruby

131V5463 1

4270

481000

2.0

8116

1.5

1.5

1.5

1.5 0.09 0.09

15

15

100 Ruby

131V5463 1

2995

481865

2.0

8116

1.5

1.5

1.5

1.5 0.09 0.09

15

15

180 Ruby

131V5463 1

4270

486265

14

14

2.0

8116

1.5

1.5

1.5

1.5 0.09 0.09

-20

75

131V5497

2995

482740

1.6

mm

0.6 0.036 0.036

10

-10

55

PUR

1.5

1.5

1.5

1.5 0.09 0.09

-20

75

PUR

131V5497

495900

1.5

1.5

1.5

1.5 0.09 0.09

-20

75

PUR

131V5497

495910

AC
W

Coil
Group

DC
W
0.5
to 3
0.3
to 3
0.3
to 3
8

BSP

1/4''

(2)

Flow
factors

2.5
*

7.0

6740

3.0/6.0/8.0 8024

2 3.0/6.0/8.0 8024
0.3 3.0/6.0/8.0 8024
to 3
1.6 3.0/6.0/8.0 8024

1.5

1.5

1.5

1.5 0.09 0.09

-20

75

PUR

131V5497

2995

496125

2.5

2.5

3.5

3.5 0.21 0.21

-10

120 FKM

131V5306

4270

481000

2.1

8116

2.5

2.5

3.5

3.5 0.21 0.21

-10

100 FKM

131V5306

2995

481865

2.1

8116

2.5

2.5

3.5

3.5 0.21 0.21

-30

130 Ruby

131V5363 1

4270

481000

2.0

8116

2.5

2.5

3.5

3.5 0.21 0.21

-30

100 Ruby

131V5363 1

2995

481865

2.0

8116

2.5

2.5

3.5

3.5 0.21 0.21

-30

180 Ruby

131V5363 1

4270

486265

14

14

2.0

8116

2.5

2.5

-20

75

PUR

131V5397

2995

482740

1.6

6.0/8.0

8024

2.5

2
0.3
to 3
1.6

6.0/8.0

8024

0.18 0.18

2.5

2.5

0.18 0.18

-20

75

PUR

131V5397

495900

2.5

2.5

0.18 0.18

-20

75

PUR

131V5397

495910

2.5

2.5

0.18 0.18

-20

75

PUR

131V5397

2995

496125

6.0/8.0

8024

6.0/8.0

8024

Notes:
1.Valve only compatible with hydraulic oil and neutral liquids

252

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

0.6

-30

-20

To

1/4''

2.5

3.5

15

180

50

Drawing 6740

Drawing 8116

Drawing 8024

253

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

3/2

HIGH CORROSION RESISTANT VALVES


(303 STAINLESS STEEL)
DIRECT OPERATED

303 STAINLESS ST.


PIPE MOUNTING

UNIVERSAL
Port
size

1.5

1.5

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
1 (2) 1 (2) Min Max (MOPD) Min Max
Kv
KV
AC DC
l/min
m3/h
bar bar bar C
C
1.5 1.5 0.09 0.09 0
10
10 -10 120 FKM

1.5

1.5

1.5

1.5 0.09 0.09

10

10

-10

1.5

1.5

1.5

1.5 0.09 0.09

10

10

130 Ruby

133V5463 1

4270

481000

1.5

1.5

1.5

1.5 0.09 0.09

100 Ruby

133V5463 1

2995

481865

2.0

1.5

1.5

1.5

1.5 0.09 0.09

10

10

180 Ruby

133V5463 1

4270

486265

14

14

2.0

8116

2.5

2.5

3.5

3.5 0.21 0.21

-10

120

FKM

133V5306

4270

481000

2.1

8116

2.5

2.5

3.5

3.5 0.21 0.21

-10

100

FKM

133V5306

2995

481865

2.1

8116

2.5

2.5

3.5

3.5 0.21 0.21

130 Ruby

133V5363 1

4270

481000

2.0

8116

2.5

2.5

3.5

3.5 0.21 0.21

100 Ruby

133V5363 1

2995

481865

2.0

8116

2.5

2.5

3.5

3.5 0.21 0.21

180 Ruby

133V5363 1

4270

486265

14

14

2.0

8116

Orice

BSP

1/4''

(2)
mm

Parker LUCIFER
Valves

Flow
factors

100

FKM

Valve
Ref.

Housing
Ref.

133V5406

4270

133V5406

2995

Coil
Ref.

Power

Coil
Group

Dwg.
No.

8116

481000

AC
W
8

DC
W
8

2.1

481865

2.1

8116

2.0

8116
8116

Notes:
1.Valve only compatible with hydraulic oil and neutral liquids

254

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

1.5

1.5

-10

-10

To

1/4''

2.5

3.5

10

180

50

Drawing 8116

255

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

256

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

VALVES FOR BEVERAGE


DISPENSING - LIQUIPURE

3/2

100

Steam

Actuation

Body

Direct Operated Stainless St./Sub-base

Function
Normally Closed

mounting

257

Water

Port
Size

Orice
(mm)

Flow
Factor
Kv(l/min)

MOPD
(bar)

Max
Fluid
Temp. (C)

Parker
Valves

Page

SB

1.5 to 3

4.2

14

140

258

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

3/2

VALVES FOR BEVERAGE DISPENSING LIQUIPURE


DIRECT OPERATED

STAINLESS ST.
SUB-BASE MOUNTING

NORMALLY CLOSED
Port
size

Orice

(2)

Kv
l/min

(2)

KV
m3/h

Operating
Fluid
Seat Seal
Pressure
Temp.
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C
0
14
14 -10 140
Ruby

Parker
Valves

Power

Valve
Ref.

Housing
Ref.

Coil
Ref.

Dwg.
No.

1.5

2.5

1.3

0.08

3019F1GRG7

D4

24.0

072

1.5

2.5

1.3

0.08

14

14

-10

140

Ruby

3019F1GRG7

D5

24.0

072

1.5

2.5

1.3

0.08

14

14

-10

140

Ruby

3019F1GRG7

LA

24.0

072

1.5

2.5

1.3

0.08

14

14

-10

140

Ruby

3019F1GRG7

LB-LC

13

16

24.0

072

1.5

2.5

1.3

0.08

14

-10

140

Ruby

3019F1GRG7

XS03

24.0

072

1.5

2.5

1.3

0.08

14

14

-10

140 FDA FKM

3019F1GVG7

D4

13

16

24.0

072

1.5

2.5

1.3

0.08

14

14

-10

140 FDA FKM

3019F1GVG7

D5

24.0

072

1.5

2.5

1.3

0.08

14

14

-10

140 FDA FKM

3019F1GVG7

LA

24.0

072

1.5

2.5

1.3

0.08

14

14

-10

140 FDA FKM

3019F1GVG7

LB-LC

13

16

24.0

072

1.5

2.5

1.3

0.08

14

-10

140 FDA FKM

3019F1GVG7

XS03

24.0

072

1.5

2.5

1.3

0.08

14

14

-10

140

Ruby

301XGFRTG7

D4

13

16

24.0

073

1.5

2.5

1.3

0.08

14

14

-10

140

Ruby

301XGFRTG7

D5

24.0

073

1.5

2.5

1.3

0.08

14

14

-10

140

Ruby

301XGFRTG7

LA

24.0

073

1.5

2.5

1.3

0.08

14

14

-10

140

Ruby

301XGFRTG7

LB-LC

13

16

24.0

073

1.5

2.5

1.3

0.08

14

-10

140

Ruby

301XGFRTG7

XS03

24.0

073

1.5

2.5

1.3

0.08

14

14

-10

140 FDA FKM

301XGFVTG7

D4

13

16

24.0

073

1.5

2.5

1.3

0.08

14

14

-10

140 FDA FKM

301XGFVTG7

D5

24.0

073

1.5

2.5

1.3

0.08

14

14

-10

140 FDA FKM

301XGFVTG7

LA

24.0

073

1.5

2.5

1.3

0.08

14

14

-10

140 FDA FKM

301XGFVTG7

LB-LC

13

16

24.0

073

1.5

2.5

1.3

0.08

14

-10

140 FDA FKM

301XGFVTG7

XS03

24.0

073

2.5

2.2

0.13

10

10

-10

140

Ruby

3019F1JRG7

D4

13

16

24.0

072

2.5

2.2

0.13

10

10

-10

140

Ruby

3019F1JRG7

D5

24.0

072

2.5

2.2

0.13

10

10

-10

140

Ruby

3019F1JRG7

LA

24.0

072

2.5

2.2

0.13

10

10

-10

140

Ruby

3019F1JRG7

LB-LC

13

16

24.0

072

mm

258

DC
W
16

Coil
Group

AC
W
13

BSP

SB

(2)

Flow
factors

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

SB

1.5

1.3

10

-10

-10

To

SB

2.2

14

140

50

Drawing 072

Drawing 073

259

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

3/2

VALVES FOR BEVERAGE DISPENSING LIQUIPURE


DIRECT OPERATED

STAINLESS ST.
SUB-BASE MOUNTING

NORMALLY CLOSED
Port
size

Orice

BSP

SB

(2)
mm

Flow
factors
1

(2)

Kv
l/min

(2)

KV
m3/h

Operating
Fluid
Seat Seal
Pressure
Temp.
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C
Ruby

Parker
Valves

Power

Valve
Ref.

Housing
Ref.

Coil
Ref.

AC
W

Coil
Group

Dwg.
No.

DC
W

2.5

2.2

0.13

10

-10

140

3019F1JRG7

XS03

24.0

072

2.5

2.2

0.13

10

10

-10

140 FDA FKM

3019F1JVG7

D4

13

16

24.0

072

2.5

2.2

0.13

10

10

-10

140 FDA FKM

3019F1JVG7

D5

24.0

072

2.5

2.2

0.13

10

10

-10

140 FDA FKM

3019F1JVG7

LA

24.0

072

2.5

2.2

0.13

10

10

-10

140 FDA FKM

3019F1JVG7

LB-LC

13

16

24.0

072

2.5

2.2

0.13

10

-10

140 FDA FKM

3019F1JVG7

XS03

24.0

072

2.5

2.2

0.13

10

10

-10

140

Ruby

301XGFRTJ7

D4

13

16

24.0

073

2.5

2.2

0.13

10

10

-10

140

Ruby

301XGFRTJ7

D5

24.0

073

2.5

2.2

0.13

10

10

-10

140

Ruby

301XGFRTJ7

LA

24.0

073

2.5

2.2

0.13

10

10

-10

140

Ruby

301XGFRTJ7

LB-LC

13

16

24.0

073

2.5

2.2

0.13

10

-10

140

Ruby

301XGFRTJ7

XS03

24.0

073

2.5

2.2

0.13

10

10

-10

140 FDA FKM

301XGFVTJ7

D4

13

16

24.0

073

2.5

2.2

0.13

10

10

-10

140 FDA FKM

301XGFVTJ7

D5

24.0

073

2.5

2.2

0.13

10

10

-10

140 FDA FKM

301XGFVTJ7

LA

24.0

073

2.5

2.2

0.13

10

10

-10

140 FDA FKM

301XGFVTJ7

LB-LC

13

16

24.0

073

2.5

2.2

0.13

10

-10

140 FDA FKM

301XGFVTJ7

XS03

24.0

073

2.5

2.5

2.8

0.17

6.5

6.5

-10

140

Ruby

3019F1LRG7

D4

13

16

24.0

072

2.5

2.5

2.8

0.17

6.5

6.5

-10

140

Ruby

3019F1LRG7

D5

24.0

072

2.5

2.5

2.8

0.17

6.5

6.5

-10

140

Ruby

3019F1LRG7

LA

24.0

072

2.5

2.5

2.8

0.17

6.5

6.5

-10

140

Ruby

3019F1LRG7

LB-LC

13

16

24.0

072

2.5

2.5

2.8

0.17

6.5

-10

140

Ruby

3019F1LRG7

XS03

24.0

072

2.5

2.5

2.8

0.17

6.5

6.5

-10

140 FDA FKM

3019F1LVG7

D4

13

16

24.0

072

2.5

2.5

2.8

0.17

6.5

6.5

-10

140 FDA FKM

3019F1LVG7

D5

24.0

072

2.5

2.5

2.8

0.17

6.5

6.5

-10

140 FDA FKM

3019F1LVG7

LA

24.0

072

2.5

2.5

2.8

0.17

6.5

6.5

-10

140 FDA FKM

3019F1LVG7

LB-LC

13

16

24.0

072

2.5

2.5

2.8

0.17

6.5

-10

140 FDA FKM

3019F1LVG7

XS03

24.0

072

2.5

2.5

2.8

0.17

6.5

6.5

-10

140

Ruby

301XGFRTL7

D4

13

16

24.0

073

2.5

2.5

2.8

0.17

6.5

6.5

-10

140

Ruby

301XGFRTL7

D5

24.0

073

2.5

2.5

2.8

0.17

6.5

6.5

-10

140

Ruby

301XGFRTL7

LA

24.0

073

2.5

2.5

2.8

0.17

6.5

6.5

-10

140

Ruby

301XGFRTL7

LB-LC

13

16

24.0

073

2.5

2.5

2.8

0.17

6.5

-10

140

Ruby

301XGFRTL7

XS03

24.0

073

2.5

2.5

2.8

0.17

6.5

6.5

-10

140 FDA FKM

301XGFVTL7

D4

13

16

24.0

073

2.5

2.5

2.8

0.17

6.5

6.5

-10

140 FDA FKM

301XGFVTL7

D5

24.0

073

2.5

2.5

2.8

0.17

6.5

6.5

-10

140 FDA FKM

301XGFVTL7

LA

24.0

073

2.5

2.5

2.8

0.17

6.5

6.5

-10

140 FDA FKM

301XGFVTL7

LB-LC

13

16

24.0

073

260

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

SB

2.2

6.5

-10

-10

To

SB

2.5

2.8

10

140

50

Drawing 072

Drawing 073

261

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES

3/2

VALVES FOR BEVERAGE DISPENSING LIQUIPURE


DIRECT OPERATED

STAINLESS ST.
SUB-BASE MOUNTING

NORMALLY CLOSED
Port
size

Orice

BSP

SB

(2)
mm

Flow
factors
1

(2)

Kv
l/min

(2)

KV
m3/h

Operating
Fluid
Seat Seal
Pressure
Temp.
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C

Parker
Valves

Power

Valve
Ref.

Housing
Ref.

Coil
Ref.

AC
W

Coil
Group

Dwg.
No.

DC
W

2.5

2.5

2.8

0.17

6.5

-10

140 FDA FKM

301XGFVTL7

XS03

24.0

073

2.5

3.3

0.2

-10

140

Ruby

3019F1NRG7

D4

13

16

24.0

072

2.5

3.3

0.2

-10

140

Ruby

3019F1NRG7

D5

24.0

072

2.5

3.3

0.2

-10

140

Ruby

3019F1NRG7

LA

24.0

072

2.5

3.3

0.2

-10

140

Ruby

3019F1NRG7

LB-LC

13

16

24.0

072

2.5

3.3

0.2

-10

140

Ruby

3019F1NRG7

XS03

24.0

072

2.5

3.3

0.2

-10

140 FDA FKM

3019F1NVG7

D4

13

16

24.0

072

2.5

3.3

0.2

-10

140 FDA FKM

3019F1NVG7

D5

24.0

072

2.5

3.3

0.2

-10

140 FDA FKM

3019F1NVG7

LA

24.0

072

2.5

3.3

0.2

-10

140 FDA FKM

3019F1NVG7

LB-LC

13

16

24.0

072

2.5

3.3

0.2

-10

140 FDA FKM

3019F1NVG7

XS03

24.0

072

2.5

4.2

0.25

-10

140

Ruby

301XGFRTN7

D4

13

16

24.0

073

2.5

4.2

0.25

-10

140

Ruby

301XGFRTN7

D5

24.0

073

2.5

4.2

0.25

-10

140

Ruby

301XGFRTN7

LA

24.0

073

2.5

4.2

0.25

-10

140

Ruby

301XGFRTN7

LB-LC

13

16

24.0

073

2.5

4.2

0.25

-10

140

Ruby

301XGFRTN7

XS03

24.0

073

2.5

4.2

0.25

-10

140 FDA FKM

301XGFVTN7

D4

13

16

24.0

073

2.5

4.2

0.25

-10

140 FDA FKM

301XGFVTN7

D5

24.0

073

2.5

4.2

0.25

-10

140 FDA FKM

301XGFVTN7

LA

24.0

073

2.5

4.2

0.25

-10

140 FDA FKM

301XGFVTN7

LB-LC

13

16

24.0

073

2.5

4.2

0.25

-10

140 FDA FKM

301XGFVTN7

XS03

24.0

073

262

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 WAY VALVES
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

SB

2.5

2.8

-10

-10

To

SB

4.2

6.5

140

50

Drawing 073

Drawing 072

263

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 & 3 WAY VALVES FOR TRANSPORTATION

264

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 & 3 WAY VALVES FOR TRANSPORTATION

2 WAY

Water

Actuation
Pilot
Operated

Body
Brass/Quick Coupling
Brass/Barb Fitting
Brass/Pipe Mounting

Function
Normally Closed
Normally Closed
Normally Closed

2/2

Port
Size

Orice
(mm)

Flow
Factor
Kv(l/min)

MOPD
(bar)

Max
Fluid
Temp. (C)

Page

Page

Parker
Valves

Parker
LUCIFER
Valves

10 mm
10 mm
12.7 mm
15.9 mm

11
11
11
11

12
12
33
36

3
3
3
3

90
90
90
90

266
266
268
268

265

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 & 3 WAY
VALVES FOR
TRANSPORTATION

2/2

2 WAY
PILOT OPERATED

BRASS
QUICK COUPLING

NORMALLY CLOSED
Port
size

Orice

Valve
Ref.

Housing
Ref.

Coil
Ref.

Voltage

Power

DC
W
9

Coil
Group

Dwg.
No.

321K1543

2168

495294

12 VDC

AC
W
-

13.0

8242

11

12

0.72

0.2

-40

90

EPDM

321K1543

2169

495294

24 VDC

13.0

8242

11

12

0.72

0.2

-40

90

EPDM

321K1543

2168

496193

12 VDC

13.0

8242

11

12

0.72

0.2

-40

90

EPDM

321K1543

2169

496193

24 VDC

13.0

8242

Voltage

Power

Coil
Group

Dwg.
No.

mm
11
10 mm

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
12 0.72 0.2
3
-40 90 EPDM

Parker LUCIFER
Valves

Flow
factors

BRASS
BARB FITTING

NORMALLY CLOSED
Port
size

Orice

Valve
Ref.

Housing
Ref.

Coil
Ref.

321K1535

2168

495294

12 VDC

AC
W
-

13.0

8241

11

12

0.72

0.2

-40

90

EPDM

321K1535

2169

495294

24 VDC

13.0

8241

11

12

0.72

0.2

-40

90

EPDM

321K1535

2168

496193

12 VDC

13.0

8241

11

12

0.72

0.2

-40

90

EPDM

321K1535

2169

496193

24 VDC

13.0

8241

mm
11
10 mm

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
3
l/min m /h l/min bar bar bar C
C
12 0.72 0.2
3
-40 90 EPDM

Parker LUCIFER
Valves

Flow
factors

266

DC
W
9

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 & 3 WAY
VALVES FOR
TRANSPORTATION
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

10 mm

11

12

-40

-40

To

10 mm

11

12

90

80

Drawing 8242

Drawing 8241

267

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 & 3 WAY
VALVES FOR
TRANSPORTATION

2/2

2 WAY
PILOT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port
size

Orice

12.7
mm

15.9
mm

Valve
Ref.

Housing
Ref.

Coil
Ref.

Voltage

Power

Dwg.
No.

321K1523

2168

495294

12 VDC

13.0

8238

11

36

2.16

0.2

-40

90

EPDM

321K1523

2169

495294

24 VDC

13.0

8238

11

36

2.16

0.2

-40

90

EPDM

321K1523

2168

496193

12 VDC

13.0

8238

11

36

2.16

0.2

-40

90

EPDM

321K1523

2169

496193

24 VDC

13.0

8238

11

33

1.98

0.2

-40

90

EPDM

321K1536

2168

495294

12 VDC

13.0

8282

11

33

1.98

0.2

-40

90

EPDM

321K1536

2169

495294

24 VDC

13.0

8282

11

33

1.98

0.2

-40

90

EPDM

321K1536

2168

496193

12 VDC

13.0

8282

11

33

1.98

0.2

-40

90

EPDM

321K1536

2169

496193

24 VDC

13.0

8282

11

36

2.16

0.2

-40

90

EPDM

321K1537

2168

495294

12 VDC

13.0

8281

11

36

2.16

0.2

-40

90

EPDM

321K1537

2169

495294

24 VDC

13.0

8281

11

36

2.16

0.2

-40

90

EPDM

321K1537

2168

496193

12 VDC

13.0

8281

11

36

2.16

0.2

-40

90

EPDM

321K1537

2169

496193

24 VDC

13.0

8281

268

DC
W
9

Coil
Group

AC
W
-

mm
11
1/2''
BSP

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
l/min m3/h l/min bar bar bar C
C
36 2.16 0.2
3
-40 90 EPDM

Parker LUCIFER
Valves

Flow
factors

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 & 3 WAY
VALVES FOR
TRANSPORTATION
For this
page

Port
size

Orice
(mm)

Kv
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/2''

11

33

-40

-40

To

15.9 mm

11

36

90

80

Drawing 8238

Drawing 8282

Drawing 8281

269

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 & 3 WAY VALVES FOR TRANSPORTATION

270

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 & 3 WAY VALVES FOR TRANSPORTATION

3 WAY

Air

Actuation
Direct
Operated

Body
Brass/Quick Coupling

Function
Normally Closed

3/2

Port
Size

Orice
(mm)

Flow
Factor
Kv(l/min)

MOPD
(bar)

Max
Fluid
Temp. (C)

Page

Page

Parker
Valves

Parker
LUCIFER
Valves

1/8''

1.8

80

272

271

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 & 3 WAY
VALVES FOR
TRANSPORTATION

3/2

3 WAY
DIRECT OPERATED

BRASS
QUICK COUPLING

NORMALLY CLOSED
Port size

Orice

BSP
1/8''

Flow
factor

(2)
mm

Qn
l/min

Operating
Fluid
Pressure
Temp.
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C

Parker LUCIFER
Valves

Seat Seal

Power

Valve
Ref.

Housing
Ref.

Coil
Ref.

AC
W

DC
W

Coil
Group

Dwg.
No.

1.8

1.5

110

-30

80

TPE/PVDF

131K0648

2161

495294

13.0

7872

1.8

1.5

110

-30

80

TPE/PVDF

131K0648

2161

496193

13.0

7872

272

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

2 & 3 WAY
VALVES FOR
TRANSPORTATION
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

1.8

110

-30

-30

To

1/8''

1.8

110

80

85

Drawing 7872

273

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY DISTRIBUTORS FOR PNEUMATIC APPLICATIONS

274

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY DISTRIBUTORS FOR PNEUMATIC APPLICATIONS

5 WAY PNEUMATIC DISTRIBUTORS


(PIPE MOUNTING/SUB-BASE MOUNTING)

Air

Actuation
Pilot
Operated

Body
Anodized aluminium/
Pipe mounting

Function
Normally Closed

Control by Electric Impulse


Anodized aluminium/
Pipe mounting/Poppet
Anodized aluminium/
Sub-base mounting
Anodized aluminium/
Sub-base mounting/
Poppet

Anodized aluminium/
CETOP/Poppet
Zinc Alloy/Pipe
mounting/Poppet
POM/CETOP/Poppet

Externally
Operated

Anodized aluminium/
Sub-base mounting

Normally Closed
Dual Solenoids
Normally Closed
Control by Electric Impulse
Normally Closed

Dual Solenoids
Control by Electric Impulse
Dual Solenoids
Normally Closed
Dual Solenoids
Normally Closed
Control by Electric Impulse
Normally Closed

5/2

Port
Size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Max
Fluid
Temp. (C)

Page

Page

Parker
Valves

Parker
LUCIFER
Valves

1/8''-1/4''
1/4''
1/2''
1/8''-1/4''
1/4''
1/8''
1/8''
1/8''
1/8''
1/8''
4 mm
4 mm
-

6
6 to 14
14
6
8 to 14
4
4
6
6
15
15
4
4
15

630
2500
2500
630
2500
400
315
630
630
5000
5000
400
315
5000

10
40
15
10
15
10
10
10
10
10
10
10
10
10

75
75
75
75
75
75
75
75
75
75
75
75
75
75

276
276
278
280
280
282
282
284
284
286
286
286
288
288

1/8''

800

10

75

288

1/4''
1/4''
1/8''
1/8''

8
8
6 to 8
6
6

1400
1400
800
800
800

10
10
10
10
10

75
100
75
75
75

290
292
292
294
296

1/8''

800

10

75

298

275

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY VALVES

5/2

5 WAY PNEUMATIC DISTRIBUTORS


(PIPE MOUNTING/SUB-BASE MOUNTING)
PILOT OPERATED

ANODIZED ALUMINIUM
PIPE MOUNTING

NORMALLY CLOSED
Port Orice
size

Flow
factor

1
BSP

1/8''1/4''

1/4''

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C
1
10
10 -10 75 FKM

Parker LUCIFER
Valves
Valve
Ref.

Housing Ref.

mm
6

Qn
l/min
630

341B34 3

4270

630

10

10

-10

75

FKM

341B34 3

2995

630

10

10

-10

75

FKM

341B34 3

630

10

10

-10

75

FKM

630

10

10

-10

75

560

10

-10

560

10

560

10

630

10

630

10

640

640

IS
Coil
Ref.

Power

Coil
Group

Dwg.
No.

481000

AC
W
8

DC
W
8

2.0

3286

481865

2.0

3286

4270

486265

14

14

2.0

3286

341B3403

4270

481000

2.1

3286

FKM

341B3403

2995

481865

2.1

3286

55

NBR

341B3490

2995

483580.01

7.0/8.0

3561

-10

75

NBR

341B3490

488660.01

7.0/8.0

3561

-10

75

NBR

341B3490

495910

7.0/8.0

3561

10

-25

75

PUR

341B3440

4270

481000

9
0.5
to 3
0.3
to 3
0.3
to 3
8

2.1

3286

10

-25

75

PUR

341B3440

2995

481865

2.1

3286

40

40

-10

75

NBR

341B02 2

4270

481000

2.1

8115

40

40

-10

75

NBR

341B02 2

2995

481865

2.1

8115

Notes:
1.Valve only compatible with air and neutral gases
2.Valve with pilot return pipe on exhaust port
3.With ow regulator

276

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY VALVES
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''-1/4''

560

10

-25

-25

To

1/4''

640

40

75

50

Drawing 3286

Drawing 3561

Drawing 8115

277

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY VALVES

5/2

5 WAY PNEUMATIC DISTRIBUTORS


(PIPE MOUNTING/SUB-BASE MOUNTING)
PILOT OPERATED

ANODIZED ALUMINIUM
PIPE MOUNTING

NORMALLY CLOSED
Port Orice
size

Flow
factor

1
BSP
1/4''

1/2''

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C
1
15
15 -10 75 NBR

Parker LUCIFER
Valves
Valve
Ref.

Housing Ref.

mm
8

Qn
l/min
1000

E341B01

2995

1000

15

15

-10

75

NBR

E341B01

4270

14

2500

15

15

-10

75

NBR

E341F21

14

2500

15

15

-10

75

NBR

14

2500

15

15

-10

75

NBR

IS
Coil
Ref.

Power

Coil
Group

Dwg.
No.

481865

AC
W
8

DC
W
9

2.1

3309

485100

2.1

3309

4270

481000

2.1

3310

E341B21 1

2995

481865

2.1

3315

E341B21 1

483371

2.1

3315

Notes:
1.Valve only compatible with air and neutral gases
2.Valve with pilot return pipe on exhaust port
3.With ow regulator

278

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY VALVES
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

1000

15

-10

-10

To

1/2''

14

2500

15

75

50

Drawing 3309

Drawing 3310

Drawing 3315

279

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY VALVES

5/2

5 WAY PNEUMATIC DISTRIBUTORS


(PIPE MOUNTING/SUB-BASE MOUNTING)
PILOT OPERATED

ANODIZED ALUMINIUM
PIPE MOUNTING

CONTROL BY ELECTRIC IMPULSE


Port Orice
size

Flow
factor

Valve
Ref.

Housing Ref.

Power
Coil
Ref.

Coil
Group

Dwg.
No.

3286

345B34 12

4269

484990

630

10

-10

75

NBR

345B34 12

4269

485400

13

4.0

3286

1000

15

-10

75

NBR

345B04

4269

484990

11

4.0

3309

mm
6
1/8''1/4''
6

1/4''

Parker LUCIFER
Valves

AC
W
11

BSP

Qn
l/min
630

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C
1
10
-10 75 NBR

DC
W
-

4.0

1000

15

-10

75

NBR

345B04

4269

485400

13

4.0

3309

14

2500

15

-10

75

NBR

345B24

4269

484990

11

4.0

3315

14

2500

15

-10

75

NBR

345B24

4269

485400

13

4.0

3315

Notes:
1.Valve only compatible with air and neutral gases
2.With ow regulator

280

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY VALVES
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''-1/4''

630

10

-10

-10

To

1/4''

14

2500

15

75

50

Drawing 3286

Drawing 3309

Drawing 3315

281

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY VALVES

5/2

5 WAY PNEUMATIC DISTRIBUTORS


(PIPE MOUNTING/SUB-BASE MOUNTING)
PILOT OPERATED

ANODIZED ALUMINIUM
PIPE MOUNTING

NORMALLY CLOSED
Port Orice
size

Flow
factor

1
BSP

1/8''

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C
1
10
10 -10 75 NBR

Parker LUCIFER
Valves
Valve
Ref.

Housing Ref.

mm
4

Qn
l/min
400

341L9101

400

10

10

-10

75

NBR

341L9101

400

10

10

-10

75

NBR

341L9101

400

10

10

-10

75

NBR

341L9101

Power
Coil
Ref.

Coil
Group

Dwg.
No.

482605

AC
W
4

DC
W
5

1.1

3894

482606

2.5

1.1

3894

8993

488980

2.5

1.1

3894

8993

495865

2.5

1.1

3894

Coil
Group

Dwg.
No.

ANODIZED ALUMINIUM
PIPE MOUNTING

DUAL SOLENOIDS
Port Orice
size

Flow
factor

1
BSP

1/8''

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C
2
10
10 -10 75 NBR

Parker LUCIFER
Valves
Valve
Ref.

Housing Ref.

mm
4

Qn
l/min
315

347L9101

315

10

10

-10

75

NBR

347L9101

315

10

10

-10

75

NBR

347L9101

315

10

10

-10

75

NBR

347L9101

282

Power
Coil
Ref.

482605

AC
W
4

DC
W
5

1.1

3896

482606

2.5

1.1

3896

8993

488980

2.5

1.1

3896

8993

495865

2.5

1.1

3896

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY VALVES
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

315

10

-10

-10

To

1/8''

400

10

75

50

Drawing 3894

Drawing 3896

283

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY VALVES

5/2

5 WAY PNEUMATIC DISTRIBUTORS


(PIPE MOUNTING/SUB-BASE MOUNTING)
PILOT OPERATED

ANODIZED ALUMINIUM
SUB-BASE MOUNTING

NORMALLY CLOSED
Port Orice
size

Flow
factor

SB

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C
1
10
10 -10 75 FKM

Parker LUCIFER
Valves
Valve
Ref.

Housing Ref.

mm
6

Qn
l/min
630

341F34 1

2995

630

10

10

-10

75

FKM

341F34 1

4270

630

10

10

-10

75

FKM

341F3403

Power
Coil
Ref.

Coil
Group

Dwg.
No.

3287

481865

AC
W
8

DC
W
9

2.1

481000

2.1

3287

2995

481865

2.1

3287

630

10

10

-10

75

FKM

341F3403

4270

481000

2.1

3287

630

10

10

-25

75

NBR

341F3440

2995

481865

2.1

3287

Coil
Group

Dwg.
No.

Notes:
1.With ow regulator

ANODIZED ALUMINIUM
SUB-BASE MOUNTING

CONTROL BY ELECTRIC IMPULSE


Port Orice
size

Flow
factor

SB

mm
6

Qn
l/min
630

630

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C
1
10
-10 75 FKM
1

10

-10

75

FKM

Parker LUCIFER
Valves
Valve
Ref.

Housing Ref.

Power
Coil
Ref.

345F34 1

4269

484990

AC
W
11

345F34 1

4269

485400

DC
W
-

4.0

3287

13

4.0

3287

Notes:
1.With ow regulator

284

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY VALVES
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

SB

630

10

-25

-25

To

SB

630

10

75

50

Drawing 3287

285

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY VALVES

5/2

5 WAY PNEUMATIC DISTRIBUTORS


(PIPE MOUNTING/SUB-BASE MOUNTING)
PILOT OPERATED

ANODIZED ALUMINIUM
SUB-BASE MOUNTING

NORMALLY CLOSED

mm
15

Qn
l/min
5000

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C
0.5 10
10 -10 75 FKM

E341L21

2995

15

5000

0.5

10

10

-10

75

FKM

E341L21

15

5000

0.5

10

-10

55

NBR

341L2190

2995

483580.01

Port Orice
size

Flow
factor

SB

SB

SB

Parker LUCIFER
Valves
Valve
Ref.

Housing Ref.

IS
Coil
Ref.

Power

Coil
Group

Dwg.
No.

481865

AC
W
8

DC
W
9

2.1/3.0

3299

495905

2.1/3.0

3299

7.0

8271

7.0

8271

7.0

8271

400

10

10

-10

75

NBR

341L9201

482605

8
0.5
to 3
0.3
to 3
0.3
to 3
5

1.1

3895

400

10

10

-10

75

NBR

341L9201

482606

2.5

1.1

3895

400

10

10

-10

75

NBR

341L9201

8993

488980

2.5

1.1

3895

400

10

10

-10

75

NBR

341L9201

8993

495865

2.5

1.1

3895

15

5000

0.5

10

-10

75

NBR

341L2190

488660.01

15

5000

0.5

10

-10

75

NBR

341L2190

495910

286

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY VALVES
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

SB

400

10

-10

-10

To

SB

15

5000

10

75

50

Drawing 3299

Drawing 8271

Drawing 3895

287

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY VALVES

5/2

5 WAY PNEUMATIC DISTRIBUTORS


(PIPE MOUNTING/SUB-BASE MOUNTING)
PILOT OPERATED

ANODIZED ALUMINIUM
SUB-BASE MOUNTING

DUAL SOLENOIDS
Port Orice
size

Flow
factor

SB

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C
2
10
10 -10 75 NBR

Parker LUCIFER
Valves
Valve
Ref.

Housing Ref.

mm
4

Qn
l/min
315

347L9201

315

10

10

-10

75

NBR

347L9201

315

10

10

-10

75

NBR

347L9201

315

10

10

-10

75

NBR

347L9201

Power
Coil
Ref.

Coil
Group

Dwg.
No.

482605

AC
W
-

DC
W
5

1.1

3897

482606

2.5

1.1

3897

8993

488980

2.5

1.1

3897

8993

495865

2.5

1.1

3897

Coil
Group

Dwg.
No.

ANODIZED ALUMINIUM
SUB-BASE MOUNTING

CONTROL BY ELECTRIC IMPULSE

mm
15

Qn
l/min
5000

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C
0.5 10
-10 75 NBR

345L21

4269

15

5000

0.5

345L21

4269

Port Orice
size

Flow
factor

SB

10

-10

75

NBR

Parker LUCIFER
Valves
Valve
Ref.

Housing Ref.

Power
Coil
Ref.

484990

AC
W
11

DC
W
-

4.0

3299

485400

13

4.0

3299

Coil
Group

Dwg.
No.

1.1

3694

ANODIZED ALUMINIUM
CETOP

DUAL SOLENOIDS
Port Orice
size

Flow
factor

1
BSP
1/8''

mm
6

Qn
l/min
800

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C
1
10
10 -10 75 NBR

Parker LUCIFER
Valves
Valve
Ref.
347L04

288

Housing Ref.

8993

Power
Coil
Ref.

488980

AC
W
2

DC
W
2.5

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY VALVES
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

SB

315

10

-10

-10

To

4 mm

15

5000

10

75

50

Drawing 3897

Drawing 3299

Drawing 3694

289

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY VALVES

5/2

5 WAY PNEUMATIC DISTRIBUTORS


(PIPE MOUNTING/SUB-BASE MOUNTING)
PILOT OPERATED

ZINC ALLOY
PIPE MOUNTING

NORMALLY CLOSED
Port Orice
size

Flow
factor

1
BSP

1/4''

1/4''
NPT

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C
1
10
10 -10 75 NBR

Parker LUCIFER
Valves
Valve
Ref.

Housing Ref.

mm
8

Qn
l/min
1400

341L11

1400

10

10

-10

75

NBR

341L11

1400

10

10

-10

75

NBR

341L11

1400

10

10

-10

75

NBR

1400

10

10

-10

75

Power
Coil
Ref.

Coil
Group

Dwg.
No.

482605

AC
W
4

DC
W
5

1.1

3434

482606

2.5

1.1

3434

8993

488980

2.5

1.1

3434

341L11

8993

495865

2.5

1.1

3434

NBR

E341L1130

2995

481865

2.1/3.0

3539
3539

1400

10

10

-10

75

NBR

E341L1130

483371

2.1/3.0

1400

10

10

-10

75

FKM

U341L1130

2995

481865

2.1

8297

1400

10

10

-10

75

FKM

U341L1130

2995

491514

11

12

2.1

8297

290

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY VALVES
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

1400

10

-10

-10

To

1/4''

1400

10

75

50

Drawing 3434

Drawing 3539

Drawing 8297

291

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY VALVES

5/2

5 WAY PNEUMATIC DISTRIBUTORS


(PIPE MOUNTING/SUB-BASE MOUNTING)
PILOT OPERATED

ZINC ALLOY
PIPE MOUNTING

DUAL SOLENOIDS
Port Orice
size

Flow
factor

1
BSP

1/4''

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C
1
10
10 -10 75 NBR

Parker LUCIFER
Valves
Valve
Ref.

Housing Ref.

mm
8

Qn
l/min
1400

347L11 1

1400

10

10

-10

75

NBR

347L11 1

1400

10

10

-10

75

NBR

347L11 1

1400

10

10

-10

75

NBR

1400

10

10

-10

100

1400

10

10

-10

100

Power
Coil
Ref.

Coil
Group

Dwg.
No.

482605

AC
W
4

DC
W
5

1.1

3461

482606

2.5

1.1

3461

8993

488980

2.5

1.1

3461

347L11 1

8993

495865

2.5

1.1

3461

FKM

E347L1130 1

2995

481865

2.1/3.0

3541

FKM

E347L1130 1

4270

481000

2.1/3.0

3541

Power

Coil
Group

Dwg.
No.

Notes:
1.With manual override

POM
CETOP

NORMALLY CLOSED
Port Orice
size

Flow
factor

1
BSP
-

mm
6

Qn
l/min
800

800

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C
1
10
10 -10 75 FKM
1

10

10

-10

75

FKM

Parker LUCIFER
Valves
Valve
Ref.

Housing Ref.

IS
Coil
Ref.

E341L02

2995

481865

AC
W
8

E341L02

4270

481000

DC
W
9

2.1/3.0

3513

2.1/3.0

3513

Notes:
1.Manual override and ow regulating screws standard
2.With manual override

292

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY VALVES
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

800

10

-10

-10

To

1/4''

1400

10

100

50

Drawing 3461

Drawing 3541

Drawing 3513

293

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY VALVES

5/2

5 WAY PNEUMATIC DISTRIBUTORS


(PIPE MOUNTING/SUB-BASE MOUNTING)
PILOT OPERATED

POM
CETOP

NORMALLY CLOSED
Port Orice
size

Flow
factor

1
BSP

1/8''

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C
1
10
10 -10 75 FKM

Parker LUCIFER
Valves
Valve
Ref.

Housing Ref.

mm
8

Qn
l/min
800

341L04 1

800

10

10

-10

75

FKM

341L04 1

800

10

10

-10

75

FKM

341L04 1

800

10

10

-10

75

FKM

800

10

-10

75

IS
Coil
Ref.

Power

Coil
Group

Dwg.
No.

482605

AC
W
4

DC
W
5

1.1

3437

482606

2.5

1.1

3437

8993

488980

2.5

1.1

3437

341L04 1

8993

495865

2.5

1.1

3437

NBR

341L0197

2995

482740

1.6

6.0/8.0

8021

2.5

6.0/8.0

8021

6.0/8.0

8021

800

10

10

-10

75

NBR

341L0197

495900

800

10

-10

75

NBR

341L0197

495910

800

10

-10

75

NBR

341L0197

2995

496125

2
0.3
to 3
1.6

6.0/8.0

8021

800

10

10

-10

75

NBR

341L05 2

482605

1.1

3430

800

10

10

-10

75

NBR

341L05 2

482606

2.5

1.1

3430

800

10

10

-10

75

NBR

341L05 2

8993

488980

2.5

1.1

3430

800

10

10

-10

75

NBR

341L05 2

8993

495865

2.5

1.1

3430

800

10

-10

75

FKM

E341L01 1

2995

482722

10

2.1/3.0

3255

800

10

10

-10

75

FKM

E341L01 1

483371

2.1/3.0

3255

800

10

10

-10

75

FKM

E341L01 1

2995.33

491514

11

12

2.1/3.0

3255

Notes:
1.Manual override and ow regulating screws standard
2.With manual override

Drawing 3255

294

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY VALVES
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

800

10

-10

-20

To

1/8''

800

10

75

50

Drawing 3437

Drawing 8021

Drawing 3430

295

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY VALVES

5/2

5 WAY PNEUMATIC DISTRIBUTORS


(PIPE MOUNTING/SUB-BASE MOUNTING)
PILOT OPERATED

POM
CETOP

CONTROL BY ELECTRIC IMPULSE


Port Orice
size

Flow
factor

1
BSP
1/8''

mm

Qn
l/min

800

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C
1

10

-10

75

FKM

Parker LUCIFER
Valves
Valve
Ref.
345L01 1

Housing Ref.

4269

Power
Coil
Ref.

485400

AC
W

DC
W

13

Coil
Group

Dwg.
No.

4.0

3255

Notes:
1.Manual override and ow regulating screws standard

296

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY VALVES
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

800

10

-10

-10

To

1/8''

800

10

75

50

Drawing 3255

297

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY VALVES

5/2

5 WAY PNEUMATIC DISTRIBUTORS


(PIPE MOUNTING/SUB-BASE MOUNTING)
EXTERNALLY OPERATED

ANODIZED ALUMINIUM
SUB-BASE MOUNTING

NORMALLY CLOSED
Port Orice
size

Flow
factor

SB

mm

Qn
l/min

800

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C
C
1
10
10 -10 75 FKM/
NBR

Parker LUCIFER
Valves
Valve
Ref.
541L01

298

Housing Ref.

Power
Coil
Ref.
-

AC
W

DC
W

Coil
Group

Dwg.
No.

3254

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

5 WAY VALVES
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

800

10

-10

-10

To

1/8''

800

10

75

50

Drawing 3254

299

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY PNEUMATIC DISTRIBUTORS FOR ACTUATION CONTROL

300

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY PNEUMATIC DISTRIBUTORS FOR ACTUATION CONTROL

3 & 5 WAY PNEUMATIC VALVES FOR


ACTUATOR CONTROL (PIPE MOUNTING)

3/2
5/2

Air

Actuation
Direct
Operated

Body
Brass/Pipe mounting

Brass/Sub-base
mounting

Pilot
Operated

Anodized aluminium/
Pipe mounting
Anodized aluminium/
Pipe mounting/Spool

Function
Normally Closed

Normally Open
Universal
Control by Electric Impulse
Normally Closed
Universal
Universal
Normally Closed

Dual Solenoids

Manual Reset Brass/Pipe mounting

Control by Electric Impulse


Universal

Port
Size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Max
Fluid
Temp. (C)

Page

Page

Parker
Valves

Parker
LUCIFER
Valves

1/8''
1/8''-1/4''
1/4''
1/4''
1/4''
1/4''
5 mm
1/8''

1.2 to 1.5
2.5
1 to 4.5
2.5
6
2.5
2.5
2

70
220
500
220
680
220
180
140

10
7
16
7
10
7
2
7

75
75
120
75
75
100
75
120

302
302
302
308
308
310
312
312

1/4''

680

10

80

314

1/8''
1/4''
1/2''
1/8''
1/4''
1/2''
1/8''
1/4''

4 to 15
7 to 8
12
4
7 to 8
12
4
6

600
1400
3000
400
1400
3000
600
680

10
10
10
10
10
10
10
10

80
80
50
80
80
50
80
65

316
318
322
324
326
328
328
330

301

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3/2

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING)
DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port Orice Flow
size

factor
1
BSP
1/8''
1/8''1/4''

1/4''

Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C C
0
10
10 -10 75 FKM

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

ATEX
Zone

Protection
Mode

Power

Dwg.
No.

1.1

3382

mm
1.2

Qn
l/min
50

131M15

8993

488980

1.5

70

-10

75

FKM

131M14

8993

488980

2.5

1.1

3382

2.5

220

-40

75

PUR

E131K0358 1 2995

481865

2.1

3510

2.5

220

-40

75

PUR

E131K0358 1 4270

481000

2.1

3510

36

10

-10

55

FKM

131K0490

2995

483580.01 0-20

Ex ia IIC T6

7.0

7058

36

10

-10

75

FKM

131K0490

488660.01 0-20

Ex ia IIC T6

7.0

7058

36

10

-10

75

FKM

131K0490

Ex ia IIC T4 to T6

8
0.5
to 3
0.3
to 3
0.3
to 3

7.0

7058

495910

0-20

AC DC
W W
2 2.5

Coil
Group

Notes:
1.With manual override

302

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

36

-40

-40

To

1/4''

2.5

220

10

75

50

Drawing 3382

Drawing 3510

Drawing 7058

303

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3/2

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING)
DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED
Port Orice Flow
size

factor
1
BSP

1/4''

Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C C
0
7
-20 75 PUR

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

ATEX
Zone

Protection
Mode

Power

mm
1.5

Qn
l/min
80

131K0497

2995

482740

1.5

80

-20

75

PUR

131K0497

495900

1-21 Ex d mb IIC T4 to T6 2.5

1.5

80

-20

75

PUR

131K0497

495910

0-20

Ex ia IIC T4 to T6

1.5

80

-20

75

PUR

131K0497

2995

496125

2-22

Ex nAC IIC T5/T6

1.5

80

16

16

-10 100 FKM

E131K04

2995

481865

1.5

80

16

16

-10 120 FKM

E131K04

4270

481000

1.5

80

16

16

-10 120 FKM

E131K04

4270

1.5

80

15

15

-10 100 FKM

1.5

80

15

15

140

10

10

140

10

140

140

140

AC DC
W W
- 1.6

Coil
Group

Dwg.
No.

6.0/8.0

8023

6.0/8.0

8023

6.0/8.0

8023

2
0.3
to 3
1.6

6.0/8.0

8023

2.0

3510

2.0

3510

486265

14 14

2.0

3510

E131K0450 1 2995

481865

2.1

3510

-10 120 FKM

E131K0450 1 4270

481000

2.1

3510

-10 100 FKM

E131K06

2995

481865

2.0

8119

10

-10 120 FKM

E131K06

4270

481000

2.0

8119

10

10

-10 120 FKM

E131K06

4270

486265

14 14

2.0

8119

10

10

-10 100 FKM

E131K0650 1 2995

481865

2.1

3510

10

10

-10 120 FKM

E131K0650 1 4270

481000

2.1

3510

Notes:
1.With manual override

304

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

1.5

80

-20

-20

To

1/4''

140

16

120

50

Drawing 8023

Drawing 3510

Drawing 8119

305

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3/2

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING)
DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY CLOSED

mm
2.5

Qn
l/min
220

Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C C
0.1 7
7
-10 75 FKM

2.5

220

0.1

-10

75

FKM

2.5

220

0.1

-10

75

2.5

220

-40

2.5

220

-40

2.5

220

2.5

220

4.5

500

4.5

500

Port Orice Flow


size

factor
1
BSP

1/4''

Parker LUCIFER
Valves
Valve
Ref.

ATEX
Zone

Protection
Mode

Power

Coil
Group

Dwg.
No.

Housing
Ref.

Coil
Ref.

E131E03

2995

481865

2.0

3525

E131E03

4270

481000

2.0

3525

FKM

E131E03

4270

486265

14 14

2.0

3525

75

PUR

E131K0308

2995

481865

2.1

3510

75

PUR

E131K0308

4270

481000

2.1

3510

-10 100 FKM

E131K0350 1 2995

481865

2.1

3510

-10 120 FKM

E131K0350 1 4270

481000

2.1

3510

-10

75

FKM

131T2101 1

2995

481865

2.1

3223

-10

75

FKM

131T2101 1

4270

481000

2.1

3223

AC DC
W W
8 9

Notes:
1.With manual override

306

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

2.5

220

-40

-40

To

1/4''

4.5

500

120

50

Drawing 3525

Drawing 3510

Drawing 3223

307

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3/2

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING)
DIRECT OPERATED

BRASS
PIPE MOUNTING

NORMALLY OPEN
Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C C
0
7
3.5 -10 75 FKM

Port Orice Flow


size

factor
1
BSP
1/4''

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

ATEX
Zone

Protection
Mode

Power

AC DC
W W
8 9

Coil
Group

Dwg.
No.

mm
2.5

Qn
l/min
220

132T29

2995

481865

2.0

3223

2.5

220

3.5

-10

75

FKM

132T29

4270

481000

2.0

3223

2.5

220

-10

75

FKM

132T29

4270

486265

14

2.0

3223

Coil
Group

Dwg.
No.

BRASS
PIPE MOUNTING

UNIVERSAL
Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
/
l min bar bar bar C C
680 0 10 10 -25 65 NBR

U133X0111

680

10

-25

75

NBR

U133X0111

680

10

10

-25

65

NBR

U133X01111D

Port Orice Flow


size
factor
1
BSP

mm
6

1/4''
NPT

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

ATEX
Zone

Protection
Mode

Coil
Ref.
492310

1-21

492965.01 0-20
483270

1-21

Ex e mb II T3 to T6
Ex ia IIC T6
Ex d IIC T4 to T6

Power

AC DC
W W
6 6 9.0/10.1/10.2 7422
0.3 9.0/10.1/10.2 7422
- to
3
8 8
11.0
7438

Notes:
1.DC voltage only. Minimum drop off voltage is 15% of nominal voltage (former DIN 19251)

308

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

2.5

220

3.5

-25

-25

To

1/4''

680

10

75

50

Drawing 3223

Drawing 7422

Drawing 7438

309

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3/2

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING)
DIRECT OPERATED

BRASS
PIPE MOUNTING

UNIVERSAL
Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C
680 0
10 -25 65 NBR

Valve
Ref.

Housing
Ref.

Coil
Ref.

U133X0131 1

492310

1-21

680

U133X0131 1

496700

1-21 Ex d mb IIC T4 to T6

Parker LUCIFER
Valves

Port Orice Flow


size
factor
1
BSP
1/4''
NPT

mm
6
6

10

-25

65

NBR

ATEX
Zone

Protection
Mode

Ex e mb II T3 to T6

Power

AC DC
W W
6

Coil
Group

Dwg.
No.

10.1/10.2

8280

10.1/10.2

8280

Power

Coil
Group

Dwg.
No.

4.0

3510

Notes:
1.DC voltage only. Minimum drop off voltage is 15% of nominal voltage (former DIN 19251)

BRASS
PIPE MOUNTING

CONTROL BY ELECTRIC IMPULSE

mm

Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C

2.5

220

Parker LUCIFER
Valves

Port Orice Flow


size

factor
1
BSP
1/4''

-10 100 FKM

Valve
Ref.
135K03

Housing
Ref.

Coil
Ref.

4269

485400

310

ATEX
Zone

Protection
Mode

AC DC
W W
-

13

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

2.5

220

-25

-25

To

1/4''

680

10

100

50

Drawing 8280

Drawing 3510

311

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3/2

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING)
DIRECT OPERATED

BRASS
SUB-BASE MOUNTING

NORMALLY CLOSED
Port Orice Flow
size

factor
1

SB

Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C C
0
2
-20 75 PUR

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

ATEX
Zone

Protection
Mode

Power

mm
2.5

Qn
l/min
180

131F4397

2995

482740

2.5

180

-20

75

PUR

131F4397

495900

1-21 Ex d mb IIC T4 to T6 2.5

2.5

180

-20

75

PUR

131F4397

495910

0-20

Ex ia IIC T4 to T6

2.5

180

-20

75

PUR

131F4397

2995

496125

2-22

Ex nAC IIC T5/T6

ATEX
Zone

Protection
Mode

AC DC
W W
- 1.6
2
0.3
to 3
1.6

Coil
Group

Dwg.
No.

6.0/8.0

8022

6.0/8.0

8022

6.0/8.0

8022

6.0/8.0

8022

Coil
Group

Dwg.
No.

2.1

3509

2.1

3509

BRASS
SUB-BASE MOUNTING

UNIVERSAL
Port Orice Flow
size

factor
1

SB

mm
2

Qn
l/min
140

140

Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C C
0
7
7
-10 100 FKM
0

-10 120 FKM

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

133F4650 1

2995

481865

133F4650 1

4270

481000

Power

AC DC
W W
8 9
8

Notes:
1.With manual override

312

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

140

-20

-20

To

5 mm

2.5

180

120

50

Drawing 8022

Drawing 3509

313

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3/2

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING)
DIRECT OPERATED

ANODIZED ALUMINIUM
PIPE MOUNTING

UNIVERSAL
Port Orice Flow
size
factor

Fluid
Temp.

Operating
Pressure
Differential
Min Max (MOPD)
Qn
AC DC
l/min bar bar bar
680 0 10 10

Min Max
C C
-25 75 NBR

133X01

680

-25 65 NBR

133X01

BSP

mm
6
6

1/4''

1/4''
NPT

10

Parker LUCIFER
Valves

Seat
Seal

Valve
Ref.

Housing
Ref.

ATEX
Zone

Protection
Mode

Power

Dwg.
No.

Coil
Ref.

AC DC
W W
492310 1-21 Ex e mb II T3 to T6 6 6 9.0/10.1/10.2 6960
0.3 9.0/10.1/10.2 6960
492965.01 0-20
Ex ia IIC T6
- to
3
496700 1-21 Ex d mb IIC T4 to T6 6 6 9.0/10.1/10.2 6960

680

10

10

-25 65 NBR

133X01

680

10

10

-25 65 NBR

133X01

496895

680

10

10

-25 80 FKM

133X01001D

483270

1-21

Ex d IIC T4 to T6

680

10

10

-25 65 NBR

U133X01

496700

1-21 Ex d mb IIC T4 to T6

314

Coil
Group

9.0/10.1/10.2 6960
11.0

7031

9.0/10.1/10.2 7422

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

680

10

-25

-25

To

1/4''

680

10

80

50

Drawing 6960

Drawing 7031

Drawing 7422

315

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

5/2

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING)
PILOT OPERATED

ANODIZED ALUMINIUM
PIPE MOUNTING

NORMALLY CLOSED
Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
AC DC
Qn
l/min bar bar bar C C
600 2
10
10 -25 50 NBR

600

10

10

-25

80

NBR

600

10

10

-25

80

NBR

600

10

10

-25

80

NBR

600

10

10

-40

65

600

10

10

-40

65

600

10

-20

65

Port Orice Flow


size
factor
1
BSP

1/8''

mm
4

600

10

10

-20

65

600

10

-20

65

600

10

-20

65

Parker LUCIFER
Valves
Valve
Ref.

ATEX
Zone

Protection
Mode

Housing
Ref.

Coil
Ref.

341P01 2

482606

1-21

Ex mb IIC T4/T5

341P01 2

8993

488980

341P21 12

2995

481865

341P21 12

4270

481000

PUR

341P2108 2

2995

PUR
NBR/
PUR
NBR/
PUR
NBR/
PUR
NBR/
PUR

341P2108 2

Power

Coil
Group

Dwg.
No.

AC DC
W W
2 2.5

1.1

7302

2.5

1.1

7302

2.1

7296

2.1

7296

481865

2.1

7296

4270

481000

2.1

7296

341P2197 2

2995

482740

1.6

6.0/8.0 8027

341P2197 2

495900

1-21

Ex d mb IIC T4 to T6

2.5

6.0/8.0 8027

341P2197 2

495910

0-20

Ex ia IIC T4 to T6

0.3
to 3

6.0/8.0 8027

341P2197 2

2995

496125

2-22

Ex nAC IIC T5/T6

1.6

6.0/8.0 8027

Notes:
1.Pilot seat in FKM
2.With manual override

316

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

600

10

-40

-40

To

1/8''

600

10

80

50

Drawing 7302

Drawing 7296

Drawing 8027

317

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

5/2

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING)
PILOT OPERATED

ANODIZED ALUMINIUM
PIPE MOUNTING

NORMALLY CLOSED
Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C

Port Orice Flow


size
factor
1
BSP

1/8''

1/4''

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

ATEX
Zone

Protection
Mode

Coil
Ref.

Power

Coil
Group

Dwg.
No.

7.0

7351

7.0

7351

7.0

7351

1.2

8218

15

600

10

-10

55

NBR

341P2190 2

2995

483580.01 0-20

Ex ia IIC T6

15

600

10

-10

75

NBR

341P2190 2

488660.01 0-20

Ex ia IIC T6

15

600

10

-10

75

NBR

341P2190 2

495910

0-20

Ex ia IIC T4 to T6

1250 2.5

10

10

-10

50

NBR

341P03 2

496131

AC DC
W W
0.5
- to
3
0.3
- to
3
0.3
- to
3
3 3

1250 2.5

10

10

-10

50

NBR

341P03 2

496482

1.2

8218

1250 2.5

10

10

-10

50

NBR

341P03 2

496637

22

Ex tD A22 IP65 - T95C

1.2

8218

1250 2.5

10

10

-10

50

NBR

341P33 2

2995

481865

2.1

8219

1250 2.5

10

10

-10

50

NBR

341P33 2

495870

2-22

Ex nAC IIC T3/T4

2.1

8219

1250 2.5

10

10

-10

50

NBR

341P33 2

495905

1-21

Ex d mb IIC T4

2.1

8219

1400

10

10

-25

80

NBR

341P02 2

482606

1-21

Ex mb IIC T4/T5

2.5

1.1

7314

1400

10

10

-25

80

NBR

341P02 2

8993

488980

2.5

1.1

7314

mm

Notes:
1.Pilot seat in FKM
2.With manual override

Drawing 7314

318

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

600

10

-25

-25

To

1/4''

15

1400

10

80

50

Drawing 7351

Drawing 8218

Drawing 8219

319

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

5/2

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING)
PILOT OPERATED

ANODIZED ALUMINIUM
PIPE MOUNTING

NORMALLY CLOSED
Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C
1400 2
10
10 -25 80 NBR

1400

10

10

-25

80

NBR

1400

10

-25

55

NBR

341P2290

2995

483580.01 0-20

1400

10

-25

75

NBR

341P2290

488660.01 0-20

Ex ia IIC T6

1400

10

-25

75

NBR

341P2290

495910

0-20

Ex ia IIC T4 to T6

8
0.5
to 3
0.3
to 3
0.3
to 3

80

NBR/
PUR
NBR/
PUR
NBR/
PUR
NBR/
PUR

341P2297 2

2995

482740

1.6

6.0/8.0 8030

Port Orice Flow


size
factor
1
BSP

1/4''

mm
8

1400

10

-20

1400

10

10

-20

80

1400

10

-20

80

1400

10

-20

80

Parker LUCIFER
Valves
Valve
Ref.

ATEX
Zone

Protection
Mode

Power

Housing
Ref.

Coil
Ref.

341P22 2

2995

481865

AC DC
W W
8 9

341P22 2

4270

481000

Ex ia IIC T6

Coil
Group

Dwg.
No.

2.1

7319

2.1

7319

7.0

7352

7.0

7352

7.0

7352

341P2297 2

495900

1-21

Ex d mb IIC T4 to T6

2.5

6.0/8.0 8030

341P2297 2

495910

0-20

Ex ia IIC T4 to T6

0.3
to 3

6.0/8.0 8030

341P2297 2

2995

496125

2-22

Ex nAC IIC T5/T6

1.6

6.0/8.0 8030

Notes:
1.Pilot seat in FKM
2.With manual override

320

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

1400

10

-25

-25

To

1/4''

1400

10

80

50

Drawing 7319

Drawing 7352

Drawing 8030

321

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

5/2

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING)
PILOT OPERATED

ANODIZED ALUMINIUM
PIPE MOUNTING

NORMALLY CLOSED

mm
12

Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C
3000 2.5 10
10 -10 50 NBR

12

3000 2.5

10

10

-10

50

NBR

12

3000 2.5

10

10

-10

50

NBR

12

3000 2.5

10

10

-10

50

12

3000 2.5

10

10

-10

12

3000 2.5

10

10

-10

Port Orice Flow


size
factor
1
BSP

1/2''

Parker LUCIFER
Valves
Valve
Ref.

ATEX
Zone

Protection
Mode

Power

Coil
Group

Dwg.
No.

Housing
Ref.

Coil
Ref.

341P04 2

496131

AC DC
W W
3 3

1.2

8220

341P04 2

496482

1.2

8220

341P04 2

496637

22

Ex tD A22 IP65 - T95C

1.2

8220

NBR

341P34 2

2995

481865

2.1

8221

50

NBR

341P34 2

2995

495870

2-22

Ex nAC IIC T3/T4

2.1

8221

50

NBR

341P34 2

495905

1-21

Ex d mb IIC T4

2.1

8221

Notes:
1.Pilot seat in FKM
2.With manual override

322

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/2''

12

3000

10

-10

-10

To

1/2''

12

3000

10

50

50

Drawing 8220

Drawing 8221

323

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

5/2

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING)
PILOT OPERATED

ANODIZED ALUMINIUM
PIPE MOUNTING

DUAL SOLENOIDS
Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C
400 2 10 10 -25 80 NBR

400

10

10

-25

80

NBR

400

10

10

-25

80

400

10

10

-25

400

10

-25

400

10

400

10

Port Orice Flow


size
factor
1
BSP

1/8''

mm
4

Parker LUCIFER
Valves

Protection
Mode

Power

Coil
Group

Dwg.
No.

1.1

7306

Housing
Ref.

Coil
Ref.

347P01 2

482606

1-21

Ex mb IIC T4/T5

AC DC
W W
2 2.5

347P01 2

8993

488980

2 2.5

1.1

7306

NBR

347P21 12

2995

481865

2.1

7298

80

NBR

347P21 12

4270

481000

2.1

7298

55

NBR

347P2190

2995

483580.01 0-20

7.0

7353

-25

75

NBR

347P2190

488660.01 0-20

7.0

7353

-25

75

NBR

347P2190

7.0

7353

NBR/
PUR
NBR/
PUR
NBR/
PUR
NBR/
PUR

347P2197 2

2995

482740

347P2197 2

495900

1-21

Ex d mb IIC T4 to T6

400

10

-20

65

400

10

10

-20

65

400

10

-20

65

400

10

-20

65

Valve
Ref.

ATEX
Zone

495910

0-20

Ex ia IIC T6
Ex ia IIC T6
Ex ia IIC T4 to T6

8
0.5
- to
3
0.3
- to
3
0.3
- to
3

1.6

2.5 2

347P2197 2

495910

0-20

Ex ia IIC T4 to T6

0.3
- to
3

347P2197 2

2995

496125

2-22

Ex nAC IIC T5/T6

1.6

6.0/8.0

8028

6.0/8.0

8028

6.0/8.0

8028

6.0/8.0

8028

Notes:
1.Pilot seat in FKM
2.With manual override

Drawing 8028

324

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

400

10

-25

-25

To

1/8''

400

10

80

50

Drawing 7306

Drawing 7298

Drawing 7353

325

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

5/2

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING)
PILOT OPERATED

ANODIZED ALUMINIUM
PIPE MOUNTING

DUAL SOLENOIDS
Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C
1250 2.5 10 10 -10 50 NBR

1250 2.5

10

10

-10

50

NBR

1250 2.5

10

10

-10

50

1250 2.5

10

10

-10

1250 2.5

10

10

-10

1250 2.5

10

10

-10

50

1400

10

10

-25

80

1400

10

10

-25

80

1400

10

10

-25

1400

10

10

-25

Port Orice Flow


size
factor
1
BSP

1/4''

mm
7

Parker LUCIFER
Valves
Valve
Ref.

ATEX
Zone

Protection
Mode

Power

Coil
Group

Dwg.
No.

1.2

8222

Housing
Ref.

Coil
Ref.

347P03 2

496131

347P03 2

496482

1.2

8222

NBR

347P03 2

496637

22

Ex tD A22 IP65 - T95C

1.2

8222

50

NBR

347P33 2

2995

481865

2.1

8223

50

NBR

347P33 2

2995

495870

2-22

Ex nAC IIC T3/T4

2.1

8223

NBR

347P33 2

495905

1-21

Ex d mb IIC T4

2.1

8223

NBR

347P02 2

482606

1-21

Ex mb IIC T4/T5

2 2.5

1.1

7316

NBR

347P02 2

8993

488980

2 2.5

1.1

7316

80

NBR

347P22 2

2995

481865

2.1

7321

80

NBR

347P22 2

4270

481000

2.1

7321

AC DC
W W
3 3

Notes:
1.Pilot seat in FKM
2.With manual override

Drawing 7321

326

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

1250

10

-25

-25

To

1/4''

1400

10

80

50

Drawing 8222

Drawing 8223

Drawing 7316

327

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

5/2

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING)
PILOT OPERATED

ANODIZED ALUMINIUM
PIPE MOUNTING

DUAL SOLENOIDS

mm
12

Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C
3000 2.5 10 10 -10 50 NBR

12

3000 2.5

10

10

-10

50

NBR

12

3000 2.5

10

10

-10

50

NBR

12

3000 2.5

10

10

-10

50

12

3000 2.5

10

10

-10

50

12

3000 2.5

10

10

-10

50

Parker LUCIFER
Valves

Port Orice Flow


size
factor
1
BSP

1/2''

Valve
Ref.

ATEX
Zone

Protection
Mode

Power

Coil
Group

Dwg.
No.

1.2

8224

Housing
Ref.

Coil
Ref.

347P04 2

496131

347P04 2

496482

1.2

8224

347P04 2

496637

22

Ex tD A22 IP65 - T95C

1.2

8224

NBR

347P34 2

2995

481865

2.1

8225

NBR

347P34 2

2995

495870

2-22

Ex nAC IIC T3/T4

2.1

8225

NBR

347P34 2

495905

1-21

Ex d mb IIC T4

2.1

8225

Coil
Group

Dwg.
No.

4.0

8123

AC DC
W W
3 3

Notes:
1.Pilot seat in FKM
2.With manual override

ANODIZED ALUMINIUM
PIPE MOUNTING

CONTROL BY ELECTRIC IMPULSE


Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C

Parker LUCIFER
Valves

Port Orice Flow


size

factor
1
BSP
1/8''

mm
4

600

10

-25

80

NBR

Valve
Ref.
345P21

Housing
Ref.

Coil
Ref.

4269

485400

328

ATEX
Zone

Protection
Mode

Power

AC DC
W W
-

13

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''

600

10

-25

-25

To

1/2''

12

3000

10

80

50

Drawing 8224

Drawing 8225

Drawing 8123

329

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3/2

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING)
MANUAL RESET

BRASS
PIPE MOUNTING

UNIVERSAL
Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C
680 0
10 10 -25 65 NBR

Valve
Ref.

Housing
Ref.

Coil
Ref.

U033X0111

492310

1-21

680

U033X0111

496700

1-21 Ex d mb IIC T4 to T6

Port Orice Flow


size
factor
1
BSP
1/4''
NPT

mm
6
6

10

10

-25 65

NBR

Parker LUCIFER
Valves

330

ATEX
Zone

Protection
Mode

Ex e mb II T3 to T6

Power

Coil
Group

Dwg.
No.

AC DC
W W
6 6 10.1/10.2/12.0 7641
6

10.1/10.2/12.0 7641

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

680

10

-25

-25

To

1/4''

680

10

65

65

Drawing 7641

331

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY PNEUMATIC DISTRIBUTORS FOR ACTUATION CONTROL

332

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY PNEUMATIC DISTRIBUTORS FOR ACTUATION CONTROL

3 & 5 WAY PNEUMATIC VALVES FOR


ACTUATOR CONTROL (NAMUR)

3/2
5/2
5/3

Air

Actuation
Direct
Operated
Pilot
Operated

Body
Anodized aluminium/
NAMUR
Anodized aluminium/
NAMUR/Spool

Function
Normally Closed
Solenoid operated - spring
return
Dual Solenoids

W1 closed center position

Anodized aluminium/
NAMUR/Poppet
Air Operated Anodized aluminium/
NAMUR

W3 exhausted in center
position
Control by Electric Impulse
Solenoid operated - spring
return
W1 closed center position
Air operated - spring return

Air operated and return

Port
Size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Max
Fluid
Temp. (C)

Page

Page

Parker
Valves

Parker
LUCIFER
Valves

1/4''

680

10

75

334

1/8''-1/4''
1/4''
1/2''
1/8''-1/4''
1/4''
1/2''
1/8''-1/4''
1/4''

4 to 8
7 to 8
12
4
7 to 8
12
4
4 to 7

1400
1400
3000
400
1400
3000
400
1250

10
10
10
10
10
10
10
10

80
80
50
80
120
120
80
120

340
336
336
352
354
356
358
358

1/4''

1250

10

50

360

1/8''-1/4''

600

10

80

362

1/8''-1/4''

355

10

75

362

1/4''
1/8''-1/4''
1/4''
1/2''
1/4''

7
4
7
12
7

1250
600
1250
3000
1250

10
10
10
10
10

50
80
50
50
50

372
368
366
366
370

333

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3/2

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (NAMUR)
DIRECT OPERATED

ANODIZED ALUMINIUM
NAMUR

NORMALLY CLOSED
Port Orice Flow
size

factor
1
BSP

1/4''

1/4''
NPT

Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C C
0
10
10 -25 75 NBR

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

ATEX
Zone

Protection
Mode

Power

Coil
Group

Dwg.
No.

Coil
Ref.

mm
6

Qn
l/min
680

AC DC
W W
492310 1-21 Ex e mb II T3 to T6 6 6 9.0/10.1
0.3 9.0/10.1
492965.01 0-20
Ex ia IIC T6
- to
3
496700 1-21 Ex d mb IIC T4 to T6 6 6 9.0/10.1

131X1101

680

10

-25

75

NBR

131X1101

680

10

10

-25

75

NBR

131X1101

680

10

10

-25

75

NBR

131X1101

496895

9.0/10.1

680

10

-25

65

NBR

131X1131 1

492310

1-21

Ex e mb II T3 to T6

10.1/10.2 7336

680

10

-25

65

NBR

131X1131 1

496700

1-21 Ex d mb IIC T4 to T6

10.1/10.2 7336

680

10

-25

65

NBR

131X1131 1

496895

680

10

-25

75

NBR

U131X1101

680

10

10

-25

65

NBR

U131X1101

496700

680

10

10

-25

65

NBR

U131X1101

496895

492965.01 0-20

Ex ia IIC T6

1-21 Ex d mb IIC T4 to T6
-

7336
7336
7336
7336

8 10.1/10.2 7336
0.3 10.1/10.2 7336
- to
3
6 6 10.1/10.2 7336
8

10.1/10.2 7336

Notes:
1.DC voltage only. Minimum drop off voltage is 15% of nominal voltage (former DIN 19251)

334

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

680

10

-25

-25

To

1/4''

680

10

75

65

Drawing 7336

335

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3/2

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (NAMUR)
PILOT OPERATED

ANODIZED ALUMINIUM
NAMUR
SOLENOID OPERATED - SPRING RETURN
Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C
1250 2.5 10
10 -10 50 NBR

1250

2.5

10

10

-10

50

NBR

1250

2.5

10

10

-10

50

NBR

12

3000

10

10

-10

50

12

3000

10

10

-10

12

3000

10

10

-10

12

3000

10

10

12

3000

10

10

Port Orice Flow


size

factor
1
BSP
1/4''

1/2''

mm
7

Parker LUCIFER
Valves
Valve
Ref.

ATEX
Zone

Housing
Ref.

Coil
Ref.

331N03 3

496131

331N03 3

496482

331N03 3

496637

NBR

331N04 3

496131

50

NBR

331N04 3

496482

50

NBR

331N04 3

496637

-10

50

NBR

331N0402

496131

-10

50

NBR

331N0402

496482

Protection
Mode

Power

Coil Dwg.
Group No.

AC DC
W W
3 3

1.2

8056

1.2

8056

22

Ex tD A22 IP65 - T95C

1.2

8056

1.2

8060

1.2

8060

22

Ex tD A22 IP65 - T95C

1.2

8060

1.2

8251

1.2

8251

Notes:
1.DC voltage only. Minimum drop off voltage is 15% of nominal voltage (former DIN 19251)
2.With captured exhaust
3.With manual override

336

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

1250

10

-10

-10

To

1/2''

12

3000

10

50

50

Drawing 8056

Drawing 8060

Drawing 8251

337

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3/2

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (NAMUR)
PILOT OPERATED

ANODIZED ALUMINIUM
NAMUR
SOLENOID OPERATED - SPRING RETURN

mm
12

Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C
3000 2.5 10
10 -10 50 NBR

12

3000

2.5

10

10

-10

50

NBR

12

3000

2.5

10

10

-10

50

NBR

12

3000

2.5

10

10

-10

50

NBR

Port Orice Flow


size

factor
1
BSP

1/2''

Parker LUCIFER
Valves
Valve
Ref.

ATEX
Zone

Protection
Mode

Housing
Ref.

Coil
Ref.

331N34 3

2995

481865

331N34 3

2995

495870

2-22

331N34 3

495905

331N3402

2995

481865

Power

Coil Dwg.
Group No.

AC DC
W W
8 9

2.1

8210

Ex nAC IIC T3/T4

2.1

8210

1-21

Ex d mb IIC T4

2.1

8210

2.1

8252

Notes:
1.DC voltage only. Minimum drop off voltage is 15% of nominal voltage (former DIN 19251)
2.With captured exhaust
3.With manual override

338

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/2''

12

3000

10

-10

-10

To

1/2''

12

3000

10

50

50

Drawing 8210

Drawing 8252

339

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (NAMUR)

3/2-5/2 PILOT OPERATED


ANODIZED ALUMINIUM
NAMUR

SOLENOID OPERATED - SPRING RETURN


Operating
Pressure
Differential
1
Min Max (MOPD)
Qn
AC DC
mm l/min bar bar bar
4
600 2
10 10

Port Orice Flow


size
factor

BSP

1/8''1/4''

Fluid
Temp.

Seat Seal

Parker LUCIFER
Valves
Valve
Ref.

Min Max
C C
-25 80

NBR

341N01 23

NBR

Housing
Ref.

Coil
Ref.

ATEX
Zone

Protection
Mode

Power

AC DC
W W
2 2.5

Coil
Group

Dwg.
No.

1.1

7301

8993

488980

600

10

10

-25 80

341N11 23

8993

488980

2.5

1.1

7300

600

10

10

-25 80 FKM/NBR 341N21 3

2995

481865

2.1

7311

600

10

10

-25 80 FKM/NBR 341N21 3

4270

481000

600

10

-25 55 FKM/NBR 341N2190 3

2995

600

10

-25 55 FKM/NBR 341N2190 3

483580.01 0-20
495910

0-20

Ex ia IIC T6
Ex ia IIC T4 to T6

8
0.5
- to
3
0.3
- to
3

2.1

7311

7.0/8.0

7874

7.0/8.0

7874

Notes:
1.DC voltage only. Minimum drop off voltage is 15% of nominal voltage (former DIN 19251)
2.With captured exhaust
3.With manual override

Drawing 7874

340

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''-1/4''

600

10

-25

-25

To

1/8''-1/4''

600

10

80

50

Drawing 7301

Drawing 7300

Drawing 7311

341

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (NAMUR)

3/2-5/2 PILOT OPERATED


ANODIZED ALUMINIUM
NAMUR

SOLENOID OPERATED - SPRING RETURN


Operating
Pressure
Differential
1
Min Max (MOPD)
Qn
AC DC
mm l/min bar bar bar
4
600 2
10 10

Port Orice Flow


size
factor

BSP

1/8''1/4''

Fluid
Temp.

Seat Seal

Valve
Ref.

Min Max
C C
-25 80

Parker LUCIFER
Valves
Housing
Ref.

Coil
Ref.

ATEX
Zone

Protection
Mode

Power

AC DC
W W
8 9

Coil
Group

Dwg.
No.

2.1

7295

NBR

341N31 3

2995

481865

600

10

10

-25 80

NBR

341N31 3

2995

495870

2-22

Ex nAC IIC T3/T4

2.1

7295

600

10

10

-25 65

NBR

341N31 3

495905

1-21

Ex d mb IIC T4

2.1

7295

600

10

10

-25 80

NBR

341N3102

2995

481865

2.1

7295

600

10

10

-40 65

PUR

341N3108 3

2995

481865

2.1

7295

600

10

10

-40 65

PUR

341N3108 3

4270

481000

2.1

7295

600

10

10

-40 65

PUR

341N3128

2995

481865

2.1

7295

600

10

10

-40 65

PUR

341N3128

4270

481865

2.1

7295

600

10

-25 80 FKM/NBR 341N3130 13

2995

481865

2.1

7295

600

10

-25 80 FKM/NBR 341N3130 13

492190

1-21

Ex e mb IIC T3/T4

2.1

7295

600

10

-25 80 FKM/NBR 341N3130 13

495905

1-21

Ex d mb IIC T4

2.1

7295

600

10

-10 55

NBR

341N3190

2995

483580.01 0-20

Ex ia IIC T6

600

10

-10 75

NBR

341N3190

488660.01 0-20

Ex ia IIC T6

600

10

-10 75

NBR

341N3190

495910

0-20

Ex ia IIC T4 to T6

600

10

-25 65

NBR

341N3196

2995

482740

8
0.5
to 3
0.3
to 3
0.3
to 3
1.6

600

10

10

-25 65

NBR

341N3196

495900

1-21

Ex d mb IIC T4 to T6

2.5

600

10

-25 65

NBR

341N3196

495910

0-20

Ex ia IIC T4 to T6

600

10

-25 65

NBR

341N3196

2995

496125

2-22

Ex nAC IIC T5/T6

600

10

-25 65

NBR

341N3197 3

2995

482740

600

10

10

-25 65

NBR

341N3197 3

495900

600

10

-25 65

NBR

341N3197 3

495910

600

10

-25 65

NBR

341N3197 3

2995

496125

7.0

7349

7.0

7349

7.0

7349

6.0/8.0

8017

2
0.3
- to
3
- 1.6

6.0/8.0

8017

6.0/8.0

8017

6.0/8.0

8017

1.6

6.0/8.0

8017

1-21

Ex d mb IIC T4 to T6

2.5

8017

Ex ia IIC T4 to T6

6.0/8.0

8017

2-22

Ex nAC IIC T5/T6

2
0.3
- to
3
- 1.6

6.0/8.0

0-20

6.0/8.0

8017

Notes:
1.DC voltage only. Minimum drop off voltage is 15% of nominal voltage (former DIN 19251)
2.With captured exhaust
3.With manual override

342

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''-1/4''

600

10

-40

-25

To

1/8''-1/4''

600

10

80

50

Drawing 7295

Drawing 7349

Drawing 8017

343

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (NAMUR)

3/2-5/2 PILOT OPERATED


ANODIZED ALUMINIUM
NAMUR

SOLENOID OPERATED - SPRING RETURN


Operating
Fluid Seat Seal
Pressure
Temp.
Differential
1
Min Max (MOPD) Min Max
Qn
AC DC
mm l/min bar bar bar C C

Port Orice Flow


size
factor

BSP

1/8''1/4''

1/4''

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

ATEX
Zone

Protection
Mode

Coil
Ref.

Power

Coil
Group

Dwg.
No.

7.0

7350

7.0

7350

AC DC
W W
0.5
- to
3
0.3
- to
3
0.3
- to
3
- 1.6

7.0

7350

6.0/8.0

8029

2.5

2
0.3
- to
3
- 1.6

6.0/8.0

8029

6.0/8.0

8029

6.0/8.0

8029

1.6

6.0/8.0

8029

2
0.3
- to
3
- 1.6

6.0/8.0

8029

6.0/8.0

8029

1400

10

-25 55

NBR

341N3290

2995

483580.01 0-20

Ex ia IIC T6

1400

10

-25 75

NBR

341N3290

488660.01 0-20

Ex ia IIC T6

1400

10

-25 75

NBR

341N3290

495910

0-20

Ex ia IIC T4 to T6

1400

10

-20 80

NBR

341N3296

2995

482740

1400

10

10

-20 80

NBR

341N3296

495900

1-21

Ex d mb IIC T4 to T6

1400

10

-20 80

NBR

341N3296

495910

0-20

Ex ia IIC T4 to T6

1400

10

-20 80

NBR

341N3296

2995

496125

2-22

Ex nAC IIC T5/T6

1400

10

-20 80

NBR

341N3297 3

2995

482740

1400

10

10

-20 80

NBR

341N3297 3

495900

1-21

Ex d mb IIC T4 to T6

2.5

1400

10

-20 80

NBR

341N3297 3

495910

0-20

Ex ia IIC T4 to T6

1400

10

-20 80

NBR

341N3297 3

2995

496125

2-22

Ex nAC IIC T5/T6

6.0/8.0

8029

1250 2.5

10

10

-10 50

NBR

341N05 3

496131

1.2

8162

1250 2.5

10

10

-10 50

NBR

341N05 3

496482

1.2

8162

1250 2.5

10

10

-10 50

NBR

341N05 3

496637

22

Ex tD A22 IP65 - T95C 3

1.2

8162

Notes:
1.DC voltage only. Minimum drop off voltage is 15% of nominal voltage (former DIN 19251)
2.With captured exhaust
3.With manual override

344

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''-1/4''

1250

10

-25

-25

To

1/4''

1400

10

80

50

Drawing 7350

Drawing 8029

Drawing 8162

345

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (NAMUR)

3/2-5/2 PILOT OPERATED


ANODIZED ALUMINIUM
NAMUR

SOLENOID OPERATED - SPRING RETURN


Operating
Pressure
Differential
1
Min Max (MOPD)
Qn
AC DC
mm l/min bar bar bar
7 1200 2.5 10 10

Port Orice Flow


size
factor

BSP

1/4''

Fluid
Temp.

Seat Seal

Min Max
C C
-10 50

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

ATEX
Zone

Protection
Mode

Power

AC DC
W W
3 3

Coil
Group

Dwg.
No.

NBR

341N0502

496131

1.2

8253

1200 2.5

10

10

-10 50

NBR

341N0502

496482

1.2

8253

1200 2.5

10

10

-10 50

NBR

341N35 3

2995

481865

2.1

8213

1200 2.5

10

10

-10 50

NBR

341N35 3

2995

495870

2-22

Ex nAC IIC T3/T4

2.1

8213

1200 2.5

10

10

-10 50

NBR

341N35 3

495905

1-21

Ex d mb IIC T4

2.1

8213

1200 2.5

10

10

-10 50

NBR

341N3502

2995

481865

2.1

8254

1200 2.5

10

10

-10 50

NBR

341N3502

4270

481000

2.1

8254

1400

10

10

-25 80

NBR

341N02 23

8993

488980

2.5

1.1

7313

Notes:
1.DC voltage only. Minimum drop off voltage is 15% of nominal voltage (former DIN 19251)
2.With captured exhaust
3.With manual override

Drawing 7313

346

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

1200

10

-25

-25

To

1/4''

1400

10

80

50

Drawing 8253

Drawing 8213

Drawing 8254

347

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (NAMUR)

3/2-5/2 PILOT OPERATED


ANODIZED ALUMINIUM
NAMUR

SOLENOID OPERATED - SPRING RETURN


Operating
Pressure
Differential
1
Min Max (MOPD)
Qn
AC DC
mm l/min bar bar bar
8 1400 2
10 10

Port Orice Flow


size
factor

BSP

1/4''

Fluid
Temp.

Seat Seal

Valve
Ref.

Min Max
C C
-25 80

Parker LUCIFER
Valves
Housing
Ref.

Coil
Ref.

ATEX
Zone

Protection
Mode

Power

AC DC
W W
2 2.5

Coil
Group

Dwg.
No.

NBR

341N12 23

8993

488980

1.1

7312

1400

10

10

-25 80

NBR

341N22 3

2995

481865

2.1

7318

1400

10

10

-25 80

NBR

341N22 3

4270

481000

2.1

7318

1400

10

10

-25 80

NBR

341N32 3

2995

481865

2.1

7317

1400

10

10

-25 80

NBR

341N32 3

2995

495870

2-22

Ex nAC IIC T3/T4

2.1

7317

1400

10

10

-25 80

NBR

341N32 3

495905

1-21

Ex d mb IIC T4

2.1

7317

1400

10

10

-25 80

NBR

341N3202

2995

481865

2.1

7317

1400

10

10

-25 80

NBR

341N3202

2995

495870

2-22

Ex nAC IIC T3/T4

2.1

7317

1400

10

10

-25 80

NBR

341N3202

495905

1-21

Ex d mb IIC T4

2.1

7317

Notes:
1.DC voltage only. Minimum drop off voltage is 15% of nominal voltage (former DIN 19251)
2.With captured exhaust
3.With manual override

348

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

1400

10

-25

-25

To

1/4''

1400

10

80

50

Drawing 7312

Drawing 7318

Drawing 7317

349

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

5/2

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (NAMUR)
PILOT OPERATED

ANODIZED ALUMINIUM
NAMUR
SOLENOID OPERATED - SPRING RETURN
Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C
1250 2.5 10
10 -10 50 NBR

1250

2.5

10

10

-10

50

NBR

1250

2.5

10

10

-10

50

NBR

12

3000

10

10

-10

50

12

3000

10

10

-10

12

3000

10

10

-10

12

3000

2.5

10

10

12

3000

2.5

10

12

3000

2.5

10

Port Orice Flow


size

factor
1
BSP
1/4''

1/2''

mm
7

Parker LUCIFER
Valves
Valve
Ref.

ATEX
Zone

Protection
Mode

Power

Coil
Group

Dwg.
No.

Housing
Ref.

Coil
Ref.

341N03 3

496131

341N03 3

496482

341N03 3

496637

22

NBR

341N04 3

496131

50

NBR

341N04 3

496482

50

NBR

341N04 3

496637

22

-10

50

NBR

341N34 3

2995

481865

10

-10

50

NBR

341N34 3

2995

495870

2-22

Ex nAC IIC T3/T4

2.1

8211

10

-10

50

NBR

341N34 3

495905

1-21

Ex d mb IIC T4

2.1

8211

AC DC
W W
3 3

1.2

8063

1.2

8063

Ex tD A22 IP65 - T95C 3

1.2

8063

1.2

8065

1.2

8065

Ex tD A22 IP65 - T95C 3

1.2

8065

2.1

8211

Notes:
1.DC voltage only. Minimum drop off voltage is 15% of nominal voltage (former DIN 19251)
2.With captured exhaust
3.With manual override

350

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

1250

10

-10

-10

To

1/2''

12

3000

10

50

50

Drawing 8063

Drawing 8065

Drawing 8211

351

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

5/2

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (NAMUR)
PILOT OPERATED

ANODIZED ALUMINIUM
NAMUR

DUAL SOLENOIDS
Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C
400 2
10 10 -25 50 NBR

400

10

10

-25

80

NBR

400

10

10

-25

80

400

10

10

-25

400

10

10

-25

Port Orice Flow


size
factor
1
BSP

1/8''1/4''

mm
4

Parker LUCIFER
Valves
Valve
Ref.

ATEX
Zone

Protection
Mode

Power

Coil
Group

Dwg.
No.

1.1

7305

Housing
Ref.

Coil
Ref.

347N11 12

482606

1-21

Ex mb IIC T4/T5

347N11 12

8993

488980

2.5

1.1

7305

FKM

347N31 2

2995

481865

2.1

7297

80

FKM

347N31 2

2995

495870

2-22

Ex nAC IIC T3/T4

2.1

7297

80

FKM

347N31 2

495905

1-21

Ex d mb IIC T4

Ex ia IIC T6

483580.01 0-20

AC DC
W W
2 2.5

400

10

-25

55

PUR

347N3190

2995

400

10

-25

65

FKM

347N3197 2

2995

482740

400

10

10

-25

65

FKM

347N3197 2

495900

1-21

Ex d mb IIC T4 to T6

2.5

400

10

-25

65

FKM

347N3197 2

495910

0-20

Ex ia IIC T4 to T6

400

10

-25

65

FKM

347N3197 2

2995

496125

2-22

Ex nAC IIC T5/T6

8
2.1
7297
0.5
7.0
8141
to 3
1.6 3.0/6.0/8.0 7297
2 3.0/6.0/8.0 7297
0.3 3.0/6.0/8.0 7297
to 3
1.6 3.0/6.0/8.0 7297

Notes:
1.With captured exhaust
2.With manual override

352

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''-1/4''

400

10

-25

-25

To

1/8''-1/4''

400

10

80

50

Drawing 7305

Drawing 7297

Drawing 8141

353

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

5/2

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (NAMUR)
PILOT OPERATED

ANODIZED ALUMINIUM
NAMUR

DUAL SOLENOIDS
Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C
1250 1.5 10 10 -10 50 NBR

1250 1.5

10

10

-10

50

NBR

1250 1.5

10

10

-10

50

1250 2.5

10

1250 2.5

7
8

Port Orice Flow


size
factor
1
BSP

1/4''

Parker LUCIFER
Valves

Protection
Mode

Housing
Ref.

Coil
Ref.

347N03 2

496131

347N03 2

496482

NBR

347N03 2

496637

10

-10 120 NBR

347N33 2

2995

481865

10

10

-10 120 NBR

347N33 2

2995

495870

2-22

1250 2.5

10

10

-10 120 NBR

347N33 2

495905

1400

10

10

-10

65

NBR

347N12 12

482606

1400

10

10

-25

80

NBR

347N12 12

8993

1400

10

10

-25

80

NBR

347N32 2

2995

1400

10

10

-25

80

NBR

347N32 2

2995

1400

10

10

-25

80

NBR

347N32 2

mm
7

Valve
Ref.

ATEX
Zone

Power

AC DC
W W
3 3

Coil
Group

Dwg.
No.

1.2

8057

1.2

8057

22 Ex tD A22 IP65 - T95C 3

1.2

8057

2.1

8209

Ex nAC IIC T3/T4

2.1

8209

1-21

Ex d mb IIC T4

2.1

8209

1-21

Ex mb IIC T4/T5

2.5

1.1

7315

488980

2.5

1.1

7315

481865

2.1

7320

495870

2-22

Ex nAC IIC T3/T4

2.1

7320

495905

1-21

Ex d mb IIC T4

2.1

7320

Notes:
1.With captured exhaust
2.With manual override

Drawing 7320

354

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

1250

10

-25

-25

To

1/4''

1400

10

120

50

Drawing 8057

Drawing 8209

Drawing 7315

355

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

5/2

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (NAMUR)
PILOT OPERATED

ANODIZED ALUMINIUM
NAMUR

DUAL SOLENOIDS
Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C
3000 1.5 10 10 -10 50 NBR

12

3000 1.5

10

10

-10

50

NBR

12

3000 1.5

10

10

-10

50

12

3000 2.5

10

12

3000 2.5

12

3000 2.5

Port Orice Flow


size
factor
1
BSP

1/2''

mm
12

Parker LUCIFER
Valves
Valve
Ref.

ATEX
Zone

Protection
Mode

Housing
Ref.

Coil
Ref.

347N04 2

496131

347N04 2

496482

NBR

347N04 2

496637

10

-10 120 NBR

347N34 2

2995

481865

10

10

-10 120 NBR

347N34 2

2995

495870

2-22

10

10

-10 120 NBR

347N34 2

495905

1-21

Power

AC DC
W W
3 3

Coil
Group

Dwg.
No.

1.2

8154

1.2

8154

22 Ex tD A22 IP65 - T95C 3

1.2

8154

2.1

8212

Ex nAC IIC T3/T4

2.1

8212

Ex d mb IIC T4

2.1

8212

Notes:
1.With captured exhaust
2.With manual override

356

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/2''

12

3000

10

-10

-10

To

1/2''

12

3000

10

120

50

Drawing 8154

Drawing 8212

357

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

5/3

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (NAMUR)
PILOT OPERATED

ANODIZED ALUMINIUM
NAMUR

W1 CLOSED CENTER POSITION


Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C
400 2
10
10 -25 80 NBR
400

10

10

-25

80

NBR

400

10

-10

65

NBR

1250

10

10

-10

50

1250

10

10

-10

50

1250

10

10

-10

50

1250 2.5

10

1250 2.5

1250 2.5

Port Orice Flow


size
factor
1
BSP

mm
4
1/8''1/4''
4

1/4''

Parker LUCIFER
Valves
Valve
Ref.

ATEX
Zone

Protection
Mode

Power

Housing
Ref.

Coil
Ref.

342N11 12

482606

1-21

Ex mb IIC T4/T5

342N11 12

8993

488980

342N3197 2

495910

0-20

Ex ia IIC T4 to T6

NBR

342N03 2

496131

2.5
0.3
- to
3
3 3

NBR

342N03 2

496482

NBR

342N03 2

496637

22

Ex tD A22 IP65 - T95C

10

-10 120 NBR

342N33 2

2995

481865

10

10

-10 120 NBR

342N33 2

2995

495870

2-22

10

10

-10 120 NBR

342N33 2

495905

1-21

AC DC
W W
2 2.5
2

Coil
Group

Dwg.
No.

1.1

7305

1.1

7305

6.0/8.0

7297

1.2

8057

1.2

8057

1.2

8057

2.1

8209

Ex nAC IIC T3/T4

2.1

8209

Ex d mb IIC T4

2.1

8209

Notes:
1.With captured exhaust
2.With manual override

Drawing 8209

358

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''-1/4''

400

10

-25

-25

To

1/4''

1250

10

120

50

Drawing 7305

Drawing 7297

Drawing 8057

359

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

5/3

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (NAMUR)
PILOT OPERATED

ANODIZED ALUMINIUM
NAMUR
W3 EXHAUSTED IN CENTER POSITION
Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C
1250 3
10
10 -10 50 NBR

1250

10

10

-10

50

NBR

1250

10

10

-10

50

NBR

Port Orice Flow


size

factor
1
BSP

1/4''

mm
7

Parker LUCIFER
Valves
Valve
Ref.

ATEX
Zone

Protection
Mode

Housing
Ref.

Coil
Ref.

343N03 1

496131

343N03 1

496482

343N03 1

496637

22

Power

AC DC
W W
3 3

Coil
Group

Dwg.
No.

1.2

8057

1.2

8057

Ex tD A22 IP65 - T95C 3

1.2

8057

Notes:
1.With manual override

360

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

1250

10

-10

-10

To

1/4''

1250

10

50

50

Drawing 8057

361

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (NAMUR)

3/2-5/2 PILOT OPERATED


ANODIZED ALUMINIUM
NAMUR

CONTROL BY ELECTRIC IMPULSE


Port Orice Flow
size

factor
1
BSP
1/8''1/4''

mm

Qn
l/min

600

Operating
Fluid
Seat Seal
Pressure
Temp.
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C C
2

10

-25

80

FKM/NBR

Parker LUCIFER
Valves
Valve
Ref.
345N31 12

Housing
Ref.

Coil
Ref.

4269

485400

ATEX Protection
Zone
Mode

Power

Coil
Group

Dwg.
No.

4.0

7295

AC DC
W W
-

13

Notes:
1.Pilot seat in FKM
2.With manual override

ANODIZED ALUMINIUM
NAMUR
SOLENOID OPERATED - SPRING RETURN
Operating
Parker LUCIFER
Fluid
Seat Seal
Pressure
Temp.
Valves
Differential
Valve
Housing
Coil
Min Max (MOPD) Min Max
Ref.
Ref.
Ref.
Qn
AC DC
l/min bar bar bar C C
355 1
10
10 -10 75
NBR
341L9504 12
482605

ATEX
Zone

1-21

Ex mb IIC T4

1.1

7009

355

10

10

-10

75

NBR

341L9504 12

482606

1-21

Ex mb IIC T4/T5

2.5

1.1

7009

355

10

10

-10

75

NBR

341L9504 12

8993

488980

2.5

1.1

7009

355

10

10

-10

75

NBR

341L9504 12

8993

495865

2-22

Ex nAC IIC T5

2.5

1.1

7009

355

10

10

-10

75

NBR

341L9534 12

2995

481865

355

10

10

-10

75

NBR

341L9534 12

2995

495870

2-22

Ex nAC IIC T3/T4

2.1/7.0 3990

355

10

10

-10

75

NBR

341L9534 12

495905

1-21

Ex d mb IIC T4

2.1/7.0 3990

Port Orice Flow


size
factor
1
BSP

1/8''1/4''

mm
4

Protection
Mode

Power

AC DC
W W
4 5

Coil Dwg.
Group No.

2.1/7.0 3990

Notes:
1.Pilot seat in FKM
2.With manual override

362

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''-1/4''

355

10

-25

-25

To

1/8''-1/4''

600

10

80

50

Drawing 7295

Drawing 7009

Drawing 3990

363

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (NAMUR)

3/2-5/2 PILOT OPERATED


ANODIZED ALUMINIUM
NAMUR

SOLENOID OPERATED - SPRING RETURN


Operating
Fluid
Seat Seal
Pressure
Temp.
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C

Port Orice Flow


size
factor
1
BSP

1/8''1/4''

mm

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.
2995

355

10

-10

55

NBR

341L9594

355

10

-10

75

NBR

341L9594 1 2

ATEX
Zone

Protection
Mode

Coil
Ref.
483580.01 0-20
495910

Ex ia IIC T6

0-20

Ex ia IIC T4 to T6

Power

Coil Dwg.
Group No.

AC DC
W W
0.5
7.0
3992
- to
3
0.3
7.0
3992
- to 3
- 1.6 6.0/8.0 8025

355

10

-10

75

NBR/PUR

341L9597 2

2995

482740

355

10

10

-10

75

NBR/PUR

341L9597 2

495900

1-21 Ex d mb IIC T4 to T6 2.5

355

10

-10

75

NBR/PUR

341L9597 2

495910

0-20

Ex ia IIC T4 to T6

355

10

-10

75

NBR/PUR

341L9597 2

2995

496125

2-22

Ex nAC IIC T5/T6

2 6.0/8.0 8025
0.3 6.0/8.0 8025
to 3
1.6 6.0/8.0 8025

355

10

-25

55

NBR/PUR

341L9598

2995

Ex ia IIC T6

0.5
to 3

483580.01 0-20

7.0

3992

Notes:
1.Pilot seat in FKM
2.With manual override

364

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''-1/4''

355

10

-25

-10

To

1/8''-1/4''

355

10

75

50

Drawing 3992

Drawing 8025

365

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3/2

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (NAMUR)
EXTERNALLY OPERATED

ANODIZED ALUMINIUM
NAMUR

AIR OPERATED - SPRING RETURN


Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C
1250 2.5 10
10 -10 50 NBR
3000

Port Orice Flow


size

factor
1
BSP
1/4''

mm
7

1/2''

12

2.5

10

10

-10

50

NBR

Parker LUCIFER
Valves
Valve
Ref.

ATEX
Zone

Protection
Mode

Housing
Ref.

Coil
Ref.

531N03

531N04

366

Power

AC DC
W W
-

Coil
Group

Dwg.
No.

8058

8061

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

1250

10

-10

-10

To

1/2''

12

3000

10

50

50

Drawing 8058

Drawing 8061

367

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (NAMUR)

3/2-5/2 EXTERNALLY OPERATED


ANODIZED ALUMINIUM
NAMUR

AIR OPERATED - SPRING RETURN


Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C
600
2
10
10 -25 80 NBR
600

Port Orice Flow


size

factor
1
BSP
1/8''1/4''

mm
4
4

10

10

-40

50

NBR

Parker LUCIFER
Valves
Valve
Ref.

ATEX
Zone

Protection
Mode

Housing
Ref.

Coil
Ref.

541N01

541N0108

368

Power

AC DC
W W
-

Coil
Group

Dwg.
No.

7309

7309

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/8''-1/4''

600

10

-40

-40

To

1/8''-1/4''

600

10

80

50

Drawing 7309

369

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

5/2

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (NAMUR)
EXTERNALLY OPERATED

ANODIZED ALUMINIUM
NAMUR

AIR OPERATED - SPRING RETURN

1/4''

mm
7

Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C
1250 2.5 10
10 -10 50 NBR

1/2''

12

3000

Parker LUCIFER
Valves

Port Orice Flow


size

factor
1
BSP

2.5

10

10

-10

50

NBR

Valve
Ref.

ATEX
Zone

Protection
Mode

Housing
Ref.

Coil
Ref.

541N03

541N04

ATEX
Zone

Protection
Mode

Power

AC DC
W W
-

Coil
Group

Dwg.
No.

8064

8066

Coil
Group

Dwg.
No.

8059

ANODIZED ALUMINIUM
NAMUR

AIR OPERATED AND RETURN

mm

Qn
l/min

Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
AC DC
bar bar bar C C

1250

2.5

Port Orice Flow


size

factor
1
BSP
1/4''

10

10

-10

50

NBR

Parker LUCIFER
Valves
Valve
Ref.
547N03

Housing
Ref.

Coil
Ref.

370

Power

AC DC
W W
-

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

1250

10

-10

-10

To

1/2''

12

3000

10

50

50

Drawing 8064

Drawing 8066

Drawing 8059

371

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

5/3

3 & 5 WAY PNEUMATIC VALVES


FOR ACTUATOR CONTROL (NAMUR)
EXTERNALLY OPERATED

ANODIZED ALUMINIUM
NAMUR

W1 CLOSED CENTER POSITION


Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C

Port Orice Flow


size

factor
1
BSP
1/4''

mm
7

1250

2.5

10

10

-10

50

NBR

Parker LUCIFER
Valves
Valve
Ref.
542N03

Housing
Ref.

Coil
Ref.

372

ATEX
Zone

Protection
Mode

Power

Coil
Group

Dwg.
No.

8059

AC DC
W W
-

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

1250

10

-10

-10

To

1/4''

1250

10

50

50

Drawing 8059

373

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY PNEUMATIC DISTRIBUTORS FOR ACTUATION CONTROL

374

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY PNEUMATIC DISTRIBUTORS FOR ACTUATION CONTROL

316L STAINLESS STEEL 3 & 5 WAY


VALVES FOR ACTUATOR CONTROL
(PIPE MOUNTING AND NAMUR)

3/2
5/2

Air

Actuation
Direct
Operated

Body

Function

316L Stainless St./Pipe Universal


mounting
316L Stainless St./Sub- Normally Closed
base mounting

Pilot
Operated

316L Stainless St./


NAMUR
316L Stainless St./Pipe
mounting
316L Stainless St./Pipe
mounting/Spool

Universal
Normally Closed
Normally Closed

Normally Closed
Dual Solenoids
316L Stainless St./
Normally Closed
NAMUR/Spool
Solenoid operated - spring
return
Dual Solenoids
Manual Reset 316L Stainless St./Pipe Universal
mounting

Port
Size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Max
Fluid
Temp. (C)

Page

Page

Parker
Valves

Parker
LUCIFER
Valves

1/4''
3/8''
5 mm
6 mm
1/4''

2 to 6
6
2.5
2.5
6

680
680
220
220
680

12
10
14
10
10

80
75
80
75
65

376
382
384
384
384

3/8''

680

10

75

386

3/8''

1400

10

80

388

3/8''
3/8''
3/8''-1/4''

8
8
8

1400
1400
1400

10
10
10

80
80
80

388
392
394

3/8''-1/4''

1400

10

80

394

3/8''-1/4''
1/4''
3/8''

8
6
6

1400
680
680

10
10
10

80
75
65

398
400
404

375

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3/2

316L STAINLESS STEEL 3 & 5 WAY VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING AND NAMUR)
DIRECT OPERATED

316L STAINLESS ST.


PIPE MOUNTING

UNIVERSAL
Port Orice Flow
size
factor

Fluid
Temp.

Operating
Pressure
Differential
Min Max (MOPD)
Qn
AC DC
l/min bar bar bar
140 0 12 12

Min Max

C C
-25 65 FKM U133V5595 2

140

12

-25 75 FKM U133V5595 2

140

12

12

-25 65 FKM U133V5595 2

140

12

12

-25 80 FKM U133V55951D 2

140

12

12

-25 65 FKM U133V7595

140

12

-25 60 FKM U133V7595

mm
2

1/4''
NPT

Seat
Seal

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

ATEX
Zone

Coil
Ref.
492310

1-21

492965.01 0-20
496800

1-21

483270.02 1-21

AC DC
W W
Ex e mb II T3 to T6 6 6
0.3
Ex ia IIC T6
- to
3
Ex d mb IIC T4
8 8
Ex d IIC T4 to T6

Ex e mb II T3 to T6

Coil
Group

Dwg.
No.

9.0/10.1

6713

9.0/10.1

6713

9.0/10.1

6713

11.0

6714

140

12

-25 65 FKM U133V7595

496565

0-20 Ex ia IIB/IIC T4 to T6

9.0/10.1

8166

2.5

220

8.5

-25 75 FKM U133V5695 2

492210

1-21

Ex e mb II T3 to T6

- 1.8

9.0/10.1

6713

2.5

220

8.5

-25 75 FKM U133V5695 2

Ex ia IIC T6

- 1.8

9.0/10.1

6713

2.5

220

8.5

8.5

-25 75 FKM U133V5695 2

Ex d mb IIC T4

9.0/10.1

6713

2.5

220

8.5

8.5

-10 75 FKM U133V56951D 23

Ex d IIC T4 to T6

11.0

6714

2.5

220

8.5

8.5

-25 75 FKM U133V7695

Ex e mb II T3 to T6

9.0/10.1

8166

2.5

220

8.5

-25 65 FKM U133V7695

220

8.5

-25 65 FKM U133V7695

1-21

Power

6
0.3
- to
3
- 0.3

2.5

492310

Protection
Mode

492965.01 0-20

492965.01 0-20
496800

1-21

483270.02 1-21
492310

1-21

492965.01 0-20
496565

Ex ia IIC T6

Ex ia IIC T6

0-20 Ex ia IIB/IIC T4 to T6

6
0.3
- to 3
- 0.3

9.0/10.1

8166

9.0/10.1

8166

9.0/10.1

8166

9.0/10.1

8166

Notes:
1.DC voltage only (or coil with rectier). Minimum drop off voltage is 15% of nominal voltage (former DIN 19251)
2.Valve delivered with an individual material traceability certicate (3.1 following EN10204)
3.Valve only compatible with hydraulic oil and air/neutral gases
4.With manual override

376

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

140

8.5

-25

-25

To

1/4''

2.5

220

12

80

50

Drawing 6713

Drawing 6714

Drawing 8166

377

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3/2

316L STAINLESS STEEL 3 & 5 WAY VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING AND NAMUR)
DIRECT OPERATED

316L STAINLESS ST.


PIPE MOUNTING

UNIVERSAL
Port Orice Flow
size
factor

Fluid
Temp.

Operating
Pressure
Differential
Min Max (MOPD)
Qn
AC DC
l/min bar bar bar
680 0 10 10

Min Max

680

10

680

680

680

680

Parker LUCIFER
Valves
Valve
Ref.

ATEX
Zone

Protection
Mode

Housing
Ref.

Coil
Ref.

C C
-25 65 NBR U133X5152 14

492310

1-21

10

-25 65 NBR U133X5152 14

496700

1-21 Ex d mb IIC T4 to T6

10

-25 65 NBR U133X5156 24

10

10

-25 65 NBR U133X5156 24

10

-25 65 NBR U133X5156 24

10

10

-25 65 NBR U133X5156 24

680

10

10

-25 75 NBR U133X51561D 24

680

10

10

-25 65 NBR U133X5192 12

492310

1-21

680

10

10

-25 65 NBR U133X5192 12

680

10

-25 65 NBR U133X5196 2

680

10

-25 65 NBR U133X5196 2

680

10

10

-25 65 NBR U133X5196 2

mm
6

1/4''
NPTF

Seat
Seal

Power

AC DC
W W
Ex e mb II T3 to T6 6 6

Dwg.
No.

10.1

7770

10.1

7770

6
0.3
to 3
6
0.3
to 3
6

Ex d IIC T4 to T6

11.0

7011

Ex e mb II T3 to T6

10.1

6904

496700

1-21 Ex d mb IIC T4 to T6

10.1

6904

492210

1-21

- 1.8 9.0/10.1/10.2 6904


0.3 9.0/10.1/10.2 6904
- to
3
6 6 9.0/10.1/10.2 6904

482870.01 0-20
492310

1-21

492965.01 0-20
496700

492965.01 0-20
496700

Ex ia IIC T6

Ex e mb II T3 to T6

Ex ia IIC T6

1-21 Ex d mb IIC T4 to T6

483270.02 1-21

Coil
Group

Ex e mb II T3 to T6
Ex ia IIC T6

1-21 Ex d mb IIC T4 to T6

9.0/10.1/10.2 7770
9.0/10.1/10.2 7770
9.0/10.1/10.2 7770
9.0/10.1/10.2 7770

Notes:
1.DC voltage only (or coil with rectier). Minimum drop off voltage is 15% of nominal voltage (former DIN 19251)
2.Valve delivered with an individual material traceability certicate (3.1 following EN10204)
3.Valve only compatible with hydraulic oil and air/neutral gases
4.With manual override

378

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

680

10

-25

-25

To

1/4''

680

10

75

65

Drawing 7770

Drawing 7011

Drawing 6904

379

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3/2

316L STAINLESS STEEL 3 & 5 WAY VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING AND NAMUR)
DIRECT OPERATED

316L STAINLESS ST.


PIPE MOUNTING

UNIVERSAL
Port Orice Flow
size
factor

Fluid
Temp.

Operating
Pressure
Differential
Min Max (MOPD)
Qn
AC DC
l/min bar bar bar
680 0 10 10

Min Max

C C
-25 65 NBR U133X51961D 2

680

10

10

-25 65 NBR U133X7156 4

680

10

-25 65 NBR U133X7196

680

10

-25 65 NBR U133X7196

680

10

10

-25 65 NBR U133X7196

mm
6
1/4''
NPTF

Seat
Seal

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

ATEX
Zone

Protection
Mode

Coil
Ref.
483270.02 1-21

Ex d IIC T4 to T6

Power

AC DC
W W
8 8

496700

1-21 Ex d mb IIC T4 to T6

492210

1-21

- 1.8
0.3
- to
3
6 6

492965.01 0-20
496700

Ex e mb II T3 to T6
Ex ia IIC T6

1-21 Ex d mb IIC T4 to T6

Coil
Group

Dwg.
No.

11.0

7038

9.0/10.1/10.2 8168
10.1/10.2

8169

10.1/10.2

8169

10.1/10.2

8169

Notes:
1.DC voltage only (or coil with rectier). Minimum drop off voltage is 15% of nominal voltage (former DIN 19251)
2.Valve delivered with an individual material traceability certicate (3.1 following EN10204)
3.Valve only compatible with hydraulic oil and air/neutral gases
4.With manual override

380

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

680

10

-25

-25

To

1/4''

680

10

65

65

Drawing 7038

Drawing 8168

Drawing 8169

381

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3/2

316L STAINLESS STEEL 3 & 5 WAY VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING AND NAMUR)
DIRECT OPERATED

316L STAINLESS ST.


PIPE MOUNTING

UNIVERSAL
Port Orice Flow
size
factor

Fluid
Temp.

Operating
Pressure
Differential
Min Max (MOPD)
Qn
AC DC
l/min bar bar bar
680 0 10 10

Min Max

C C
-25 65 NBR U133X5296 2

680

10

-25 65 NBR U133X5296 2

680

10

10

-25 65 NBR U133X5296 2

AC DC
W W
492310 1-21 Ex e mb II T3 to T6 6 6 9.0/10.1/10.2 7669
0.3 9.0/10.1/10.2 7669
492965.01 0-20
Ex ia IIC T6
- to
3
496700 1-21 Ex d mb IIC T4 to T6 6 6 9.0/10.1/10.2 7669

680

10

10

-25 75 NBR U133X52961D 2

483270.02 1-21

mm
6
3/8''
NPTF

Seat
Seal

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

ATEX
Zone

Protection
Mode

Power

Coil
Group

Dwg.
No.

Coil
Ref.

Ex d IIC T4 to T6

11.0

7670

Notes:
1.DC voltage only (or coil with rectier). Minimum drop off voltage is 15% of nominal voltage (former DIN 19251)
2.Valve delivered with an individual material traceability certicate (3.1 following EN10204)
3.Valve only compatible with hydraulic oil and air/neutral gases
4.With manual override

382

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/8''

680

10

-25

-25

To

3/8''

680

10

75

65

Drawing 7669

Drawing 7670

383

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3/2

316L STAINLESS STEEL 3 & 5 WAY VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING AND NAMUR)
DIRECT OPERATED

316L STAINLESS ST.


SUB-BASE MOUNTING

NORMALLY CLOSED

mm
2.5

Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C
220
0
12 -25 65 FKM

U131F5695 1

2.5

220

12

-25

65

FKM

U131F5695 1

2.5

220

12

12

-25

75

FKM

U131F5695 1

2.5

220

14

14

-10

80

FKM

U131F56951D 12

2.5

220

10

10

-25

75

FKM

U131F5295

Parker LUCIFER
Valves

Port Orice Flow


size
factor
1

SB

SB

Valve
Ref.

Housing
Ref.

ATEX
Zone

Coil
Ref.
492210

1-21

492965.01 0-20
496800

1-21

483270.02 1-21
496560

1-21

Protection
Mode

Power

Coil
Group

AC DC
W W
Ex e mb II T3 to T6 - 1.8 9.0/10.1
0.3 9.0/10.1
Ex ia IIC T6
- to
3
Ex d mb IIC T4
8 8 9.0/10.1

Dwg.
No.

3782
3782
3782

Ex d IIC T4 to T6

11.0

3783

Ex d mb IIC T4

9.0/10.1

8174

Coil
Group

Dwg.
No.

Notes:
1.Valve delivered with an individual material traceability certicate (3.1 following EN10204)
2.Valve only compatible with hydraulic oil and air/neutral gases

316L STAINLESS ST.


SUB-BASE MOUNTING

UNIVERSAL
Operating
Pressure
Differential
1
Min Max (MOPD)
Qn
AC DC
mm l/min bar bar bar
6
680 0
10 10

Port Orice Flow


size
factor

1/4''
NPTF

680

10

10

Fluid
Temp.

Seat
Seal

Min Max

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

ATEX
Zone

Protection
Mode

Power

AC DC
W W
Ex e mb II T3 to T6 6 6 9.0/10.1/10.2 3572

C C
-25 65 FKM

U133X5195 1

492310

1-21

-25 65 FKM

U133X5195 1

496700

1-21 Ex d mb IIC T4 to T6 6

9.0/10.1/10.2 3572

Notes:
1.Valve delivered with an individual material traceability certicate (3.1 following EN10204)

Drawing 3572

384

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

SB

2.5

220

10

-25

-25

To

SB

680

14

80

50

Drawing 3782

Drawing 3783

Drawing 8174

385

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3/2

316L STAINLESS STEEL 3 & 5 WAY VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING AND NAMUR)
DIRECT OPERATED

316L STAINLESS ST.


SUB-BASE MOUNTING

UNIVERSAL
Operating
Pressure
Differential
1
Min Max (MOPD)
Qn
AC DC
mm l/min bar bar bar
6
680 0
10 10

Port Orice Flow


size
factor

1/4''
NPTF

Fluid
Temp.

Seat
Seal

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

C C
-25 65 FKM

Min Max

U133X51951D 1

680

10

10

-25 65 FKM

U133X51951D 1

680

10

-25 65 FKM

U133X7195

680

10

-25 65 FKM

U133X7195

680

10

10

-25 65 FKM

U133X7195

ATEX
Zone

Protection
Mode

Coil
Ref.
1-21

Ex d IIC T4 to T6

483270.02 1-21

483270

Ex d IIC T4 to T6

492210

1-21

Power

AC DC
W W
8 8
8

Coil
Group

Dwg.
No.

11.0

3688

11.0

3688

Ex e mb II T3 to T6

- 1.8 9.0/10.1/10.2 8172


0.3 9.0/10.1/10.2 8172
492965.01 0-20
Ex ia IIC T6
- to
3
496700 1-21 Ex d mb IIC T4 to T6 6 6 9.0/10.1/10.2 8172

Notes:
1.Valve delivered with an individual material traceability certicate (3.1 following EN10204)

316L STAINLESS ST.


NAMUR

NORMALLY CLOSED
Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
1
Min Max (MOPD) Min Max
Qn
AC DC
mm l/min bar bar bar C C
6
680 0
10
10 -25 65 NBR

Port Orice Flow


size
factor

3/8''
NPT

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

U131X1201 1

680

10

-25

75

NBR

U131X1201 1

680

10

10

-25

65

NBR

U131X1201 1

ATEX
Zone

Protection
Mode

Power

Coil
Group

Dwg.
No.

Coil
Ref.

AC DC
W W
492310 1-21 Ex e mb II T3 to T6 6 6 9.0/10.1/10.2 7668
0.3 9.0/10.1/10.2 7668
492965.01 0-20
Ex ia IIC T6
- to
3
496700 1-21 Ex d mb IIC T4 to T6 6 6 9.0/10.1/10.2 7668

Notes:
1.Valve delivered with an individual material traceability certicate (3.1 following EN10204)

386

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

680

10

-25

-25

To

3/8''

680

10

75

65

Drawing 3688

Drawing 8172

Drawing 7668

387

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

5/2

316L STAINLESS STEEL 3 & 5 WAY VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING AND NAMUR)
PILOT OPERATED

316L STAINLESS ST.


PIPE MOUNTING

NORMALLY CLOSED
Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C
1400 2
10
10 -25 80 NBR

Valve
Ref.

Housing
Ref.

Coil
Ref.

U441P3250 12

4270

481000

1400

U441P3250 12

2995

481865

Parker LUCIFER
Valves

Port Orice Flow


size

factor
1

3/8''
NPT

mm
8
8

10

10

-25

80

NBR

ATEX
Zone

Protection
Mode

Power

Coil
Group

Dwg.
No.

AC DC
W W
8 8

2.1

7565

2.1

7565

Notes:
1.Pilot seat in FKM
2.Valve with external pilot pressure minimum 4 bar

316L STAINLESS ST.


PIPE MOUNTING

NORMALLY CLOSED
Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C
1400 2
10
10 -25 80 NBR

Valve
Ref.

Housing
Ref.

U341P0250 123

8993

481045

1400

10

10

-25

80

NBR

U341P0250 123

482606

1-21

Ex mb IIC T4/T5

2.5

1.1

7578

1400

10

10

-25

80

NBR

U341P3250 1

4270

481000

2.1

7558

1400

10

10

-25

80

NBR

U341P3250 1

2995

481865

2.1

7558

1400

10

10

-25

80

NBR

U341P3250 1

2995

492453

2.1

7558

Port Orice Flow


size
factor
1
mm
8
3/8''
NPT

Parker LUCIFER
Valves

ATEX
Zone

Protection
Mode

Coil
Ref.

Power

AC DC
W W
2 2.5

Coil Dwg.
Group No.

1.1

7578

Notes:
1.Pilot seat in FKM
2.With captured exhaust
3.With manual override

388

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/8''

1400

10

-25

-25

To

3/8''

1400

10

80

50

Drawing 7565

Drawing 7578

Drawing 7558

389

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

5/2

316L STAINLESS STEEL 3 & 5 WAY VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING AND NAMUR)
PILOT OPERATED

316L STAINLESS ST.


PIPE MOUNTING

NORMALLY CLOSED
Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C

Port Orice Flow


size
factor
1
mm
3/8''
NPT

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

1400

10

-25

55

NBR

U341P3292 1

2995

1400

10

10

-25

75

NBR

U341P3295 1

1400

10

-25

75

NBR

U341P3295 1

ATEX
Zone

Protection
Mode

Coil
Ref.
483580.01 0-20
492310

1-21

492965.01 0-20

Ex ia IIC T6
Ex e mb II T3 to T6
Ex ia IIC T6

Power

Coil Dwg.
Group No.

AC DC
W W
0.5
7560
- to
3 7.0
6 6 9.0/10.1 7561
0.3 9.0/10.1 7561
- to
3

Notes:
1.Pilot seat in FKM
2.With captured exhaust
3.With manual override

390

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/8''

1400

10

-25

-25

To

3/8''

1400

10

75

50

Drawing 7560

Drawing 7561

391

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

5/2

316L STAINLESS STEEL 3 & 5 WAY VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING AND NAMUR)
PILOT OPERATED

316L STAINLESS ST.


PIPE MOUNTING

DUAL SOLENOIDS
Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C
1400 2
10
10 -25 80 NBR

U347P3250 1 4270

481000

1400

10

10

-25

80

NBR

U347P3250 1

483371

1-21

Ex e mb IIC T4

2.1

7563

1400

10

10

-25

75

NBR

U347P3295 1

492310

1-21

Ex e mb II T3 to T6

10.1

7564

1400

10

10

-25

75

NBR

U347P3295 1

496800

1-21

Ex d mb IIC T4

10.1

7564

Port Orice Flow


size

factor
1
mm
8
3/8''
NPT

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

ATEX
Zone

Protection
Mode

Coil
Ref.

Power

AC DC
W W
8 8

Coil
Group

Dwg.
No.

2.1

7563

Notes:
1.Pilot seat in FKM

392

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/8''

1400

10

-25

-25

To

3/8''

1400

10

80

50

Drawing 7563

Drawing 7564

393

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

316L STAINLESS STEEL 3 & 5 WAY VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING AND NAMUR)

3/2-5/2 PILOT OPERATED


316L STAINLESS ST.
NAMUR

NORMALLY CLOSED
Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C
1400 2
10
10 -25 80 NBR

U341N3250 1 2995

1400

10

10

-25

80

NBR

U341N3250 1

1400

10

-25

55

NBR

U341N3292 1 2995

1400

10

10

-25

75

NBR

U341N3295 1

492310

1-21

Ex e mb II T3 to T6

1400

10

10

-25

75

NBR

U341N3295 1

496800

1-21

Ex d mb IIC T4

Port Orice Flow


size

factor
1
mm
8
3/8''1/4''
NPT

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

ATEX
Zone

Protection
Mode

Coil
Ref.
481865

492190

1-21

Ex e mb IIC T3/T4

483580.01 0-20

Ex ia IIC T6

Power

Coil
Group

Dwg.
No.

AC DC
W W
8 9

2.1

7554

11

2.1

7554

9
0.5
- to
3
6 6

7.0

7556

10.1

7696

10.1

7696

Notes:
1.Pilot seat in FKM
2.With captured exhaust
3.With manual override

394

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/8''-1/4''

1400

10

-25

-25

To

3/8''-1/4''

1400

10

80

50

Drawing 7554

Drawing 7556

Drawing 7696

395

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

316L STAINLESS STEEL 3 & 5 WAY VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING AND NAMUR)

3/2-5/2 PILOT OPERATED


316L STAINLESS ST.
NAMUR

SOLENOID OPERATED - SPRING RETURN


Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C
1400 2
10
10 -25 80 NBR
1400

Port size Orice Flow

factor
1

3/8''1/4''NPT

mm
8
8

10

10

-25

80

NBR

Parker LUCIFER
Valves
Valve
Ref.

ATEX
Zone

Housing
Ref.

Coil
Ref.

U341N0250 123

482606

1-21

U341N0250 123

8993

488980

Protection
Mode

Power

Coil Dwg.
Group No.

Ex mb IIC T4/T5

AC DC
W W
2 2.5

1.1

7577

2 2.5

1.1

7577

Notes:
1.Pilot seat in FKM
2.With captured exhaust
3.With manual override

396

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/8''-1/4''

1400

10

-25

-25

To

3/8''-1/4''

1400

10

80

50

Drawing 7577

397

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

5/2

316L STAINLESS STEEL 3 & 5 WAY VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING AND NAMUR)
PILOT OPERATED

316L STAINLESS ST.


NAMUR

DUAL SOLENOIDS
Port size

3/8''1/4''NPT

Operating
Fluid
Seat
Pressure
Temp. Seal
Differential
Min Max (MOPD) Min Max
Qn
AC DC
l/min bar bar bar C C
1400 2
10
10 -25 80 NBR

U347N3250 1 4270

481000

1400

U347N3250 1 2995

481865

Orice Flow

factor

mm
8
8

10

10

-25

80

NBR

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

ATEX
Zone

Protection
Mode

Coil
Ref.

Power

AC DC
W W
8 8
8

Coil
Group

Dwg.
No.

2.1

7557

2.1

7557

Notes:
1.Pilot seat in FKM

398

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/8''-1/4''

1400

10

-25

-25

To

3/8''-1/4''

1400

10

80

50

Drawing 7557

399

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3/2

316L STAINLESS STEEL 3 & 5 WAY VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING AND NAMUR)
MANUAL RESET

316L STAINLESS ST.


PIPE MOUNTING

UNIVERSAL
Operating
Pressure
Differential
1
Min Max (MOPD)
Qn
AC DC
mm l/min bar bar bar
6
680 0 10 10

Port Orice Flow


size
factor

6
1/4''
NPTF

680

10

Fluid
Temp.

Seat
Seal

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

C C
-25 65 NBR

U033X5152 12

-25 65 NBR

U033X5156 2

Min Max

ATEX
Zone

Coil
Ref.
492310

1-21

482870.01 0-20

680

10

10

-25 65 NBR

U033X5156 2

492310

1-21

680

10

-25 65 NBR

U033X5156 2

492335

0-20

496700

1-21

680

10

10

-25 65 NBR

U033X5156 2

680

10

10

-25 75 NBR

U033X51561D 2

483270.02 1-21

Protection
Mode

Power

AC DC
W W
Ex e mb II T3 to T6 6 6
0.3
Ex ia IIC T6
- to
3
Ex e mb II T3 to T6 6 6
0.3
NEMA 4-4X
- to
3
Ex d mb IIC T4 to T6 6 6
Ex d IIC T4 to T6

Coil
Group

Dwg.
No.

10.1/10.2

7029

10.1/10.2/12.0 7771
10.1/10.2/12.0 7771
10.1/10.2/12.0 7771
10.1/10.2/12.0 7771
11.0

7030

Notes:
1.DC voltage only (or coil with rectier). Minimum drop off voltage is 15% of nominal voltage (former DIN 19251)
2.Valve delivered with an individual material traceability certicate (3.1 following EN10204)

400

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

680

10

-25

-25

To

1/4''

680

10

75

65

Drawing 7029

Drawing 7771

Drawing 7030

401

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3/2

316L STAINLESS STEEL 3 & 5 WAY VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING AND NAMUR)
MANUAL RESET

316L STAINLESS ST.


PIPE MOUNTING

UNIVERSAL
Operating
Pressure
Differential
1
Min Max (MOPD)
Qn
AC DC
mm l/min bar bar bar
6
560 0 10 10

Port Orice Flow


size
factor

1/4''
NPTF

Fluid
Temp.

Seat
Seal

Min Max
C C
-25 65 NBR

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

Coil
Ref.

ATEX
Zone

Protection
Mode

Power

Coil
Group

Dwg.
No.

AC DC
W W
Ex e mb II T3 to T6 6 6 10.1/10.2/12.0 3594

U033X5195 2

492310

1-21

560

10

10

-25 65 NBR

U033X5195 2

496700

1-21 Ex d mb IIC T4 to T6

10.1/10.2/12.0 3594

680

10

10

-25 65 NBR

U033X71561

492310

1-21

Ex e mb II T3 to T6

9.0/10.1/10.2 8168

680

10

10

-25 65 NBR

U033X7156

496560

1-21

Ex d mb IIC T4

9.0/10.1/10.2 8168

680

10

10

-25 65 NBR

U033X7156

496700

1-21 Ex d mb IIC T4 to T6

9.0/10.1/10.2 8168

680

10

10

-25 65 NBR

U033X7156

496895

9.0/10.1/10.2 8168

Notes:
1.DC voltage only (or coil with rectier). Minimum drop off voltage is 15% of nominal voltage (former DIN 19251)
2.Valve delivered with an individual material traceability certicate (3.1 following EN10204)

402

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

1/4''

560

10

-25

-25

To

1/4''

680

10

65

65

Drawing 3594

Drawing 8168

403

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS

3/2

316L STAINLESS STEEL 3 & 5 WAY VALVES


FOR ACTUATOR CONTROL (PIPE MOUNTING AND NAMUR)
MANUAL RESET

316L STAINLESS ST.


PIPE MOUNTING

UNIVERSAL
Operating
Fluid Seat
Pressure
Temp. Seal
Differential
1
Min Max (MOPD) Min Max
Qn
AC DC
mm l/min bar bar bar C C

Port Orice Flow


size
factor

6
3/8''
NPTF

680

10

-25 65 NBR

Parker LUCIFER
Valves
Valve
Ref.

Housing
Ref.

U033X5256 2

ATEX
Zone

Coil
Ref.
482870.01 0-20

Protection
Mode

Power

Coil
Group

Dwg.
No.

AC DC
W W
0.3 10.1/10.2/12.0 7671
Ex ia IIC T6
- to
3
Ex e mb II T3 to T6 6 6 10.1/10.2/12.0 7671

680

10

10

-25 65 NBR

U033X5256 2

492310

1-21

680

10

10

-25 65 NBR

U033X5256 2

496700

1-21 Ex d mb IIC T4 to T6

680

10

10

-25 65 NBR

U033X52561D 2

483270

1-21

Ex d IIC T4 to T6

11.0

7672

680

10

10

-25 65 NBR

U033X52561D 2

483270.02 1-21

Ex d IIC T4 to T6

11.0

7672

10.1/10.2/12.0 7671

Notes:
1.DC voltage only (or coil with rectier). Minimum drop off voltage is 15% of nominal voltage (former DIN 19251)
2.Valve delivered with an individual material traceability certicate (3.1 following EN10204)

404

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

3 & 5 WAY
PNEUMATIC
DISTRIBUTORS
For this
page

Port
size

Orice
(mm)

Qn
(l/min)

MOPD
(bar)

Fluid Temp
(C)

Amb Temp
(C)

From

3/8''

680

10

-25

-25

To

3/8''

680

10

65

65

Drawing 7671

Drawing 7672

405

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EExPressTM Bus Manifold

406

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EExPressTM Bus Manifold

FOR PNEUMATIC ACTUATOR


CONTROL IN ATEX ZONES

407

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EExPressTM
Bus Manifold

FOR PNEUMATIC ACTUATOR CONTROL


EX BUS MANIFOLD
FOR PNEUMATIC ACTUATOR CONTROL
Parkers EExPress bus manifold package has been designed for the
control of pneumatic actuators in the Process Industry where hazardous
environments Zone 1, 21 and or Zone 2, 22 are present.
EExPress is a stackable system that includes Gateway - Input sensor
modules - Solenoid valve modules.
NAMUR Standard ON/OFF Where the (NPN) sensor can be directly
connected on the input sensor module.
The Ex manifold uses the Profibus DP protocol.

INCREASED PROCESS PRODUCTIVITY


When plant installations are
simplified, the engineering study,
component packages and man
hour costs are reduced, this
results in a quicker production
start-up.
Through more efficient process
control, quality and quantity of
production is improved.

EExPress bus manifold replaces


a lot of proprietary components,
thus reducing cost of installation.
EExPress bus manifold simplifies
commissioning time resulting in
quicker plant start up time.
EExPress bus manifold reduces
overall product life cost through
reduction in maintenance costs.

A USER FRIENDLY PRODUCT


EExPress uses the well known
profibus DP protocol.
It as been designed to aproach
a "plug and play" usage.

At a glance at the LED the user


knows immediately the current
production Process status.
Authorised users may re-adress
the 5/2 valves directly from the
manifold.

408

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EExPressTM
Bus Manifold

PLANT INSTALLATION SIMPLIFICATION


EExPress significantly reduces
the
need
of
electronic
components such as couplers,
repeaters,
safety
barriers,
PLC, etc.

It significantly reduces the need


of mechanical components
such as pressurised cabinets,
pneumatic piping, electrical
wiring, connectors, etc.

One bus address can operate


and control up to 32 x solenoid
valves on one manifold (or
combination of sensor modules
and solenoid valves).

Integrated solution with high


flow valves and sensor signal
inputs.

BETTER PROCESS & PERSONNEL SAFETY


With separated wiring, the bus
communication* is maintained
"ON" even if the coil voltage
supply is cut.
Solenoid valve status + inputs
sensor status + safety pressure
status, etc.

The diagnostic capabilities offer


permanently a real reliable
Process Control.
It provides more efficient
Process
Control
due
to
centralised mounting close to
actuators.

Ex px [ia] [ib] ib mb IIC T5


Ex tD A21 IP65 T100C
protection as well as the
patented
coil
connection
eliminate risks associated with
bad handling.
eg.: disconnection of bus or sensor
connectors in presence of gases.

PROVEN ACHIEVEMENT THROUGH


INNOVATIVE FLUID CONTROL

0081

IECEx LCI 07.0027 X

II 2/(1) G D

LCIE 01 ATEX 6013 X

Ex px [ia] [ib] ib mb IIC T5


Ex tD A21 IP65 T100C

409

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

410

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

ELECTROPNEUMATIC
PRESSURE REGULATORS

aerospace
climate control
electromechanical
filtration
fluid & gas handling
hydraulics
pneumatics
process control
sealing & shielding

411

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

ELECTROPNEUMATIC
PRESSURE REGULATORS
Lucifer EPP4 Programmable
Pressure Regulator
EPP4 is an electro pneumatic pressure regulator with
integrated electronic system.
A pulsed width modulated solenoid valve controls the output
pressure proportionally to an analog input signal.
Very high accuracy is guaranteed thanks to a high precision
closed loop signal provided by a built in pressure sensor.

Market
Robotics
Paper industry
Machine tools
Mobile
Buildings
Textile
Instrumentation
Semi conductor

Description of Applications
Welding
Speed and brake control
Sanding
Cutting
Humidication
Tension regulation
Painting
Presses
Polishing
Adaptative suspension control
412

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

Value Propositions for the Lucifer


EPP4 Range of Proportional
Pressure Regulators
O

All parameters fully adjustable through the PC software Calys

Easy to use software

Long life expectancy

Compact and light

Limited inventory

Low power

Flexible remote display positioning

Proven expertise of Parker, a pioneer


in pressure regulation technology

Calys
C
alys Software
ffor EP
EPP
PP Comfort
Calys is a unique software in house developed to configurate
all the parameters of the EPP4 Comfort range.
Calys is an option of the EPP4. To use CALYS,
you need to order cable reference 496449 wich permits the communication
between the EPP4 and a PC.
Calys offers many capabilities:
O

It enables distributors to reduce inventory by keeping a generic EPP4


in stock and adjust it to the needs of each customer application.
They can switch for example from 0-10 V to 4-20 mA, or from 0-7 bar
pressure range to 0-5 bar.

Engineers designing a pneumatic system are able to monitor


precisely all the important values (electrical or pneumatical) directly
on their laptop.

After sales technicians are able to receive via email all


the parameters measured by the EPP4 installed on a machine
wherever its location allowing remote ma intenance operation.

O PID regulation parameters can be adjusted with Calys to match


required regulator response (like slow or reactive).

To download free Calys software click on www.parker.com/FCDE/Support


413

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

ELECTROPNEUMATIC
PRESSURE REGULATORS

414

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

TABLE OF CONTENT

Introduction EPP

........................... page

EPP4 Basic Range


EPP4 Comfort
Range

..................... page

418

......................................... page

422

EPP4 Comfort HP
Range

........................ page

426

......................................... page

432

.................................................... page

438

EPP4 Comfort
Range ATEX

Accessories

415

416

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

INTRODUCTION

Description Operation
The EPP4 Series is a family of electrically remotecontrolled pneumatic pressure regulators with
closed loop integrated electronic control.

regulator; when energised this valve will fill the


servo-chamber for increasing the pressure at the
outlet A of the regulator.

It allows regulating the outlet pressure


proportionally to an electrical control signal.
The EPP4 regulator comprises a traditional
servo-operated pneumatic pressure regulator,
where the pilot chamber is fed y one or the other of
two pulse width modulated 2-way solenoid valves.

When the other "exhaust valve" is energised


(reduction of pressure at the outlet A of the
regulator), the pressure of the servo-chamber will
be exhausted through a discharge orifice located
between the cover and the body and directly fed
to the atmosphere without silencer.

The pressure sensor measures the outlet pressure


of the regulator and provides a feedback signal to
the controller.
Any difference between the control signal and the
feedback signal is converted to a digital signal to
energise the coil of one or the other 2-way valves
to correct the position of the regulator.

The exhaust of the main regulated pressure will be


made through the quick exhaust R.
The use of a conventional silencer is recommended.
Both solenoid valves assure the Filling or Emptying
of the servo-chamber in order to increase or
decrease the pressure at the outlet of the regulator.
In rest position of the valves all ports are blocked.

The control signal can be a voltage (0-10 V) or a


current (4-20 mA). The inlet of the "Filling Valve"
is connected directly to the main inlet P of the

Filling positon

Stand by position

416

Emptying position

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

Block Diagram
The controller receives both the control signal (set
pressure) and the feedback signal from the sensor
(outlet pressure).

The same feedback signal from the sensor is


used for the output feedback in voltage and
current.

Any difference between the two amplifier inputs


results in a corresponding output which drives
the appropriate 2-way pulse width modulated
solenoid valve so that the pilot piston moves to
correct the pressure.

The digital signal (alarm) is activated when the


conditions (out of pressure or time tolerance) are
met.

24 V

DC
+

Differential
amplier

U/I - Control signal

0-10 V, 4-20 mA

Pulse width
modulated
2-way solenoid
valves

Sensor output
signals

PID
W

0-10 V, 4-20 mA
0-24 V, Alarm

Feedback loop

Pressure
sensor

Regulated pressure
0.05 - 10 bar
Exhaust

Servo-chamber

EPP4 possible executions : Basic and Comfort


EPP4 Basic and Comfort ranges share the same
reliable mechanical parts. Proportional regulation
is also identical for the two different executions,
giving the same characteristics for hysteresis or
precision for instance.

PLC

U Out

Remote display

24 V

PC

Calys software

Comfort range regulators have a second M12


connector, that can be used to connect a remote
display showing the current regulated pressure,
or a PC to easily set the regulation's parameters.
These are the key feature options for a comfortable
use.

The B connector
offers connection
to the remote
display or the PC.

417

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

LUCIFER EPP4 BASIC 1/4" & 1/2"


TECHNICAL DATA
Basic 1/4"
Fluids:

Lubricated or non lubricated air and neutral gases Recommended ltration: 50 m

Temperature range:
Inlet pressure range:
The inlet pressure must always be at least 1 bar
above the regulated pressure.
Outlet pressure range:

Ambient: 0C to +50 C
Fluid: 0C to +50 C
1 to 12 bar

50 mbar (factory set up)

Air consumption at constant control signal:

Supply voltage:

24 V DC 15 % (Max. ripple 1 V)
Max. 2.8 W with 24 V DC and constant changes of the control signal
< 1.5 W without change of control signal

Control signal:
Max. ow:
Indicative response time: With a volume of 330
cm at the outlet of the regulator
Filling 2 to 4 bar:
Filling 2 to 8 bar:
Emptying 4 to 2 bar:
Emptying 8 to 2 bar:
Safety position:

Analog 0 - 10 V
Analog 4 - 20 mA
70 m3/h

150 m3/h

50 msec
100 msec
70 msc
130 msc

60 msec
120 msec
90 msec
190 msc

In case of control signal failure or if it is less than 50mV, the regulated pressure drops
automatically to 0 bar (atmospheric pressure). In case of voltage supply failure,
the regulated pressure will be kept constant.
M12 - 4 pin; 4 x 0.34 mm2

Electrical connection:
Life expectancy:
Mounting position:

> 50 Million changes of control signal steps


Indifferent (recommended position: upright; electronic part on top)

Resistance to vibrations:

30 g in all directions

Degree of protection:

IP 65

Assembly:

Silicone free

Electromagnetic compatibility:
In accordance with:

Installation and setting instructions:

1 to 12 bar

0.05 to 10 bar

Hysteresis:

Power consumption:

Basic 1/2"

EN 61000-6-1: 2001
EN 61000-6-2: 2001
EN 61000-6-3: 2001
EN 61000-6-4: 2001
See our "Notice 408038, 408014" and appendix supplied with the product.

Note: Parker reserves the right to change specifications without notification.

418

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

LUCIFER EPP4 BASIC 1/4" & 1/2"


FLOW CURVES
Flow Curve Basic 1/4"
9

Outlet pressure - bar

8
7
6
5
4
3
2
1
0
0

20

40

60

70

80

100

120

Flow rate - m3/h

Flow Curve Basic 1/2"


9

Outlet pressure - bar

8
7
6
5
4
3
2
1
0
0

25

50

75

100

125

150

175

Flow rate - Nm3/h

419

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

LUCIFER EPP4 BASIC 1/4" & 1/2"


REFERENCES
Codes

Pipe

P4BG2001A001
P4BG2001A002
P4BG2001A003
P4BG2001A004
P4BG2001A005
P4BG2001A006
P4BG2001A007
P4BG2001A008
P4BG2001A009
P4BG2003A002 *
P4BG2003A003 *

G 1/4
G 1/4"
G 1/4"
G 1/4"
G 1/4"
G 1/4"
G 1/4"
G 1/4"
G 1/4"
G 1/4
G 1/4

0
0
0
0
0
0
0
0
0
0
0

G 1/2"
G 1/2"
G 1/2"
G 1/2"
G 1/2
G 1/2
G 1/2"
G 1/2"
G 1/2
G 1/2
NPT 1/4
NPT 1/4
NPT 1/2
NPT 1/2

0
0
0
0
0
0
0
0
0
0
0
0
0
0

P4BG4001A002
P4BG4001A003
P4BG4001A004
P4BG4001A005
P4BG4001A006
P4BG4001A007
P4BG4001A008
P4BG4001A009
P4BG4004A010 ***
P4BG4051A002 **
P4BN2001A002
P4BN2001A003
P4BN4001A002
P4BN4001A003

Pressure Range
(bar)

Control Signal
(see options)

Drawing
Number

4 bar
10 bar
10 bar
6 bar
6 bar
5 bar
5 bar
7 bar
7 bar
10 bar
10 bar

4 - 20 mA
0 - 10 V
4 - 20 mA
0 - 10 V
4 - 20 mA
0 - 10 V
4 - 20 mA
0 - 10 V
4 - 20 mA
0 - 10 V
4 - 20 mA

1
1
1
1
1
1
1
1
1
1
1

10 bar
10 bar
6 bar
6 bar
5 bar
5 bar
7 bar
7 bar
4 bar
10 bar
10 bar
10 bar
10 bar
10 bar

0 - 10 V
4 - 20 mA
0 - 10 V
4 - 20 mA
0 - 10 V
4 - 20 mA
0 - 10 V
4 - 20 mA
0 - 10 V
4 - 20 mA
4 - 20 mA
0 - 10 V
4 - 20 mA
0 - 10 V

2
2
2
2
2
2
2
2
2
2
2
2
2
2

* Integrated pilot exhaust


** O2
*** External pressure supply

420

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

LUCIFER EPP4 BASIC 1/4" & 1/2"


DIMENSIONS DRAWINGS EPP4 BASIC 1/4"

Drawing 1

DIMENSIONS DRAWINGS EPP4 BASIC 1/2"

Drawing 2

421

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

LUCIFER EPP4 COMFORT 1/4" & 1/2"


TECHNICAL DATA
Comfort 1/4"
Fluids:
Temperature range:
Inlet pressure range:
The inlet pressure must always be at least 1
bar above the regulated pressure.
Outlet pressure range:
Hysteresis:
Air consumption at constant control signal:
Supply voltage:
Power consumption:

Control signal:

Outlet sensor signal:

Max. ow:
Indicative response time:
Filling 2 to 4 bar :
Filling 2 to 8 bar:
Emptying 4 to 2 bar:
Emptying 8 to 2 bar:
Safety position:

Electrical connection:
Life expectancy:
Mounting position:
Resistance to vibrations:
Degree of protection:
Assembly:
Electromagnetic compatibility:
In accordance with:

Installation and setting instructions:

Comfort 1/2"

Lubricated or non lubricated air and neutral gases - Recommended ltration: 50 m


Ambient: 0C to +50 C
Fluid: 0C to +50 C
1 to 12 bar

1 to 12 bar

0.05 to 10 bar
50 mbar (factory set up)
0
24 V DC 15 % (Max. ripple 1 V)
Max. 2.8 W with 24 V DC
and constant changes
of the control signal < 1.5 W
without change of control signal
Analog 0 - 10 V
Analog 4 - 20 mA
Analog 0 - 10 V
Digital 0/24 V for alarm features:
Standard for 0 - 10 bar; Adjustable
Adjustable pressure error (+/-)
Adjustable delay ON
Analog 4 - 20 mA
Adjustable delay OFF
Standard for 0 - 10 bar; Adjustable
Adjustable logic (+/-)
150 m3/h
70 m3/h
With a volume of 330 cm at the outlet of the regulator
50 msec
60 msec
100 msec
120 msec
70 msc
90 msec
130 msc
190 msc
In case of control signal failure or if it is less than 50 mV,
the regulated pressure drops automatically to 0 bar
(atmospheric pressure).
In case of voltage supply failure, the regulated pressure will be kept constant.
M12 - 8 pin; male connector power supply/control signal
M12 - 5 pin; male connector communication
> 50 Million changes of control signal steps
Indifferent (recommended position: upright; electronic part on top)
30 g in all directions
IP 65
Silicone free
EN 61000-6-1: 2001
EN 61000-6-2: 2001
EN 61000-6-3: 2001
+ A11 2004 edition (01/07/07)
EN 61000-6-4: 2001
See our "Notice 408128, 408134" and appendix supplied with the product.

Note: Parker reserves the right to change specifications without notification.

422

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

LUCIFER EPP4 COMFORT 1/4" & 1/2"


Flow Curves
Flow Curve 1/4"
9

Outlet pressure - bar

8
7
6
5
4
3
2
1
0
0

20

40

60

70

80

100

120

Flow rate - Nm3/h

Flow Curve 1/2"


9

Outlet pressure - bar

8
7
6
5
4
3
2
1
0
0

25

50

75

100

125

150

175

Flow rate - Nm3/h

423

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

LUCIFER EPP4 COMFORT1/4" & 1/2"


REFERENCES
Codes

Pipe

Pressure Range
(bar)

Control Signal
(see options)

Display

Drawing
Number

P4CG2001C001
P4CG2001C002
P4CG2001C005
P4CG2001C006
P4CG2002C001
P4CG2002C002
P4CG2003C001 *
P4CG2003C002 *
P4CG2002C007
P4CG2002C008
P4CN2001C001
P4CN2001C002
P4CN2002C001
P4CN2002C002

G 1/4
G 1/4
G 1/4
G 1/4
G 1/4
G 1/4
G 1/4
G 1/4
G 1/4
G 1/4
1/4 NPT
1/4 NPT
1/4 NPT
1/4 NPT

0
0
0
0
0
0
0
0
0
0
0
0
0
0

10
10
7
7
10
10
10
10
7
7
10
10
10
10

0-10 V
4-20 mA
0-10 V
4-20 mA
0-10 V
4-20 mA
0-10 V
4-20 mA
0-10 V
4-20 mA
0-10 V
4-20 mA
0-10 V
4-20 mA

included
included
included
included
included
included

3
3
3
3
3
3
3
3
3
3
3
3
3
3

P4CG4001C001
P4CG4001C002
P4CG4001C005
P4CG4001C006
P4CG4002C001
P4CG4002C002
P4CG4002C005
P4CG4002C006
P4CG4051C001 **
P4CG4051C002 **
P4CN4001C001
P4CN4001C002
P4CN4002C001
P4CN4002C002

G 1/2
G 1/2
G 1/2
G 1/2
G 1/2
G 1/2
G 1/2
G 1/2
G 1/2
G 1/2
1/2 NPT
1/2 NPT
1/2 NPT
1/2 NPT

0
0
0
0
0
0
0
0
0
0
0
0
0
0

10
10
7
7
10
10
7
7
10
10
10
10
10
10

0-10 V
4-20 mA
0-10 V
4-20 mA
0-10 V
4-20 mA
0-10 V
4-20 mA
0-10 V
4-20 mA
0-10 V
4-20 mA
0-10 V
4-20 mA

-
-
included
included
included
included
included
included

4
4
4
4
4
4
4
4
4
4
4
4
4
4

* Integrated pilot exhaust


** O2

424

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

LUCIFER EPP4 COMFORT 1/4" & 1/2"


DIMENSIONS DRAWINGS EPP4 COMFORT RANGE 1/4"

Drawing 3

DIMENSIONS DRAWINGS EPP4 COMFORT RANGE 1/2"

Drawing 4

425

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

LUCIFER EPP4 COMFORT 1/2"HP, 1" & 2"


TECHNICAL DATA
Comfort 1/2" HP
Fluids:
Temperature range:
Inlet pressure range:
The inlet pressure must always be at least 1
bar above the regulated pressure.
Outlet pressure range:

Comfort 1"

1 to 21 bar
0.05 to 20 bar

Hysteresis:
Air consumption at constant control signal:
Supply voltage:

1 to 21 bar

1 to 12 bar

0.05 to 20 bar
100 mbar if P inlet 10 bar
200 mbar if P inlet > 10 bar
0

0.05 to 10 bar

24V DC 15%
Max. 6 W with 24 V DC
and constant changes
of thecontrol signal < 2 W
without change of control signal

Power consumption:

Analog 0 - 10 V
Analog 4 - 20 mA

Control signal:

Digital 0/24 V for alarm features:


Adjustable pressure error (+/-)
Adjustable delay ON
Adjustable delay OFF
Adjustable logic (+/-)

Analog 0 - 10 V
Standard for 0 - 10 bar; Adjustable
Outlet sensor signal:
Analog 4 - 20 mA
Standard for 0 - 10 bar; Adjustable
Max. ow:
Indicative response time:
Filling 2 to 8 bar:
Emptying 8 to 2 bar:

Safety position:

Electrical connection:
Life expectancy:
Mounting position:
Resistance to vibrations:
Degree of protection:
Assembly:
Electromagnetic compatibility:
In accordance with:
Installation and setting instructions:

Comfort 2"

Lubricated or non lubricated air and neutral gases - Recommended ltration: 50 m


Ambient: 0C to +50C
Fluid: 0C to +50C

150 m3/h

1 000 m3/h

2 700 m3/h

With a volume of 330 cm at the outlet of the regulator


120 msec
250 msec
250 msec
190 msc
400 msc
400 msc
In case of control signal failure or if it is less than
50 mV, the regulated pressure drops automatically to
0 bar atmospheric pressure (for pressure ranges
from 0-10 bar, 100 mV for pressure range over 10 bar).
In case of voltage supply failure, the regulated pressure
will be kept constant.
M12 - 8 pin; male connector power supply/control signal
M12 - 5 pin; male connector communication
> 20 Million changes of control signal steps
Indifferent (recommended position: upright; electronic part on top)
30 g in all directions
IP 65
Silicone free
EN 61000-6-1: 2001
EN 61000-6-2: 2001
EN 61000-6-3: 2001
+ A11 2004 edition (01/07/07)
EN 61000-6-4: 2001
See our "408 193" and appendix supplied with the product.

Note: Parker reserves the right to change specications without notication.

426

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

LUCIFER EPP4 COMFORT 1/2"HP, 1" & 2"


FLOW CURVES
Flow Curve 1/2"HP
9

Outlet pressure - bar

8
7
6
5
4
3
2
1
0
0

25

50

75

100

125

150

175

Flow rate - Nm3/h

Flow Curve 1"


7

Outlet pressure - bar

6
5
4
3
2
1
0
0

160

320

480

640

800

960

1120

1280

1 800

2 100

2 400

Flow rate - Nm3/h

Flow Curve 2"


7

Outlet pressure - bar

6
5
4
3
2
1
0
0

300

600

900

1 200

1 500

Flow rate - Nm3/h

427

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

LUCIFER EPP4 COMFORT 1/2"HP


REFERENCES
Codes

Pipe

Max inlet pressure


(bar)

Pressure range
(bar)

Control signal
(see options)

Dimensional
Drawing

P4CG4101D001

G1/2

15

12

0-10 V

P4CG4201D005

G1/2

21

P4CG4201D003

G1/2

21

16

0-10 V

20

0-10 V

P4CG4201D004

G1/2

21

20

4-20 mA

Other specific settings or specialties are available, please contact us.

428

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

LUCIFER EPP4 COMFORT 1/2"HP


DIMENSIONS DRAWINGS

Drawing 5

Drawing 6

429

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

LUCIFER EPP4 COMFORT 1" & 2"


REFERENCES
Codes

Pipe

Max inlet pressure


(bar)

Pressure range
(bar)

Control signal
(see options)

Dimensional
Drawing

P4CG6101C009

G1

12

P4CG6101C011

G1

12

3.5

4-20 mA

5.0

0-10 V

P4CG6101C010

G1

12

P4CG6101C001

G1

12

6.0

4-20 mA

10

0-10 V

P4CG6101C002

G1

12

10

4-20 mA

P4CG6201D001

G1

21

12

P4CG6201D003

G1

21

20

0-10 V

P4CG9101C012

G2

12

4.0

4-20 mA

P4CG9101C010

G2

12

6.0

4-20 mA

P4CG9101C001

G2

12

10

0-10 V

P4CG9101C002

G2

12

10

4-20 mA

Other specific settings or specialties are available, please contact us.

430

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

LUCIFER EPP4 COMFORT 1" & 2"


DIMENSIONS DRAWINGS EPP4 COMFORT
RANGE 1"

Drawing 7

DIMENSIONS DRAWINGS EPP4 COMFORT


RANGE 2"

Drawing 8

431

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

LUCIFER EPP4 COMFORT 1/2", 1" & 2" ATEX


TECHNICAL DATA
Comfort 1/2"
ATEX
Fluids:
Temperature range:
Inlet pressure range:
The inlet pressure must always be at least 1
bar above the regulated pressure.
Outlet pressure range:
Hysteresis:
Air consumption at constant control signal:
ATEX certication:
Supply voltage:
Power consumption:
Control signal:

Outlet sensor signal:

Max. ow:
Indicative response time:
Filling 2 to 8 bar:
Emptying 8 to 2 bar:
Safety position:

Electrical connection:
Life expectancy:
Mounting position:
Resistance to vibrations:
Degree of protection:
Assembly:

Comfort 2"
ATEX

Lubricated or non lubricated air and neutral gases - Recommended ltration: 50 m


Ambient: 0C to +50C
Fluid: 0C to +50C
Inlet pressure range: 1 to 12 bar
Outlet pressure range: 0.05 to 10 bar
100 mbar
0
Ex II 3 G/D
Ex nA IIC T4 Gc
Ex tc IIIB T130C Dc
24V DC 15 %
Max. 6 W with 24 V DC
and constant changes of thecontrol signal < 2 W
without change of control signal
Analog 0 - 10 V
Analog 4 - 20 mA
Analog 0 - 10 V
Digital 0/24 V for alarm features:
Standard for 0 - 10 bar; Adjustable
Adjustable pressure error (+/-)
Adjustable delay ON
Analog 4 - 20 mA
Adjustable delay OFF
Standard for 0 - 10 bar; Adjustable
Adjustable logic (+/-)
1 000 m3/h
2 700 m3/h
150 m3/h
With a volume of 330 cm at the outlet of the regulator
120 msec
250 msec
250 msec
190 msc
400 msc
400 msc
In case of control signal failure or if it is less than 50 mV, the regulated pressure drops
automatically to 0 bar atmospheric pressure (for pressure ranges
from 0-10 bar, 100 mV for pressure range over 10 bar).
In case of voltage supply failure, the regulated pressure will be kept constant.
M12 - 8 pin; male connector power supply/control signal
M12 - 5 pin; male connector communication
> 20 Million changes of control signal steps
Indifferent (recommended position: upright; electronic part on top)
30 g in all directions
IP 54
Silicone free
EN 61000-6-1: 2001
EN 61000-6-2: 2001
EN 61000-6-3: 2001
+ A11 2004 edition (01/07/07)
EN 61000-6-4: 2001

Electromagnetic compatibility:
In accordance with:
Installation and setting instructions:

Comfort 1"
ATEX

See our "408 283" and appendix supplied with the product.

Note: Parker reserves the right to change specifications without notification.

432

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

LUCIFER EPP4 COMFORT 1/2", 1" & 2" ATEX


FLOW CURVES
Flow Curve 1/2"
9

Outlet pressure - bar

8
7
6
5
4
3
2
1
0
0

25

50

75

100

125

150

175

Flow rate - Nm3/h

Flow Curve 1"


7

Outlet pressure - bar

6
5
4
3
2
1
0
0

160

320

480

640

800

960

1120

1280

1 800

2 100

2 400

Flow rate - Nm3/h

Flow Curve 2"


7

Outlet pressure - bar

6
5
4
3
2
1
0
0

300

600

900

1 200

1 500

Flow rate - Nm3/h

433

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

LUCIFER EPP4 COMFORT 1/2" ATEX


REFERENCES
Codes

Pipe

Max inlet pressure


(bar)

Pressure range
(bar)

Control signal
(see options)

Dimensional
Drawing

P4CG4461C001

G1/2

12

10

0-10 V

P4CG4461C002

G1/2

12

10

4-20 mA

P4CG4465C001 **

G1/2

P4CG4465C002 **

G1/2

12

10

0-10 V

12

10

4-20 mA

** O2
Other specific settings or specialties are available, please contact us.

434

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

LUCIFER EPP4 COMFORT 1/2" ATEX


DIMENSIONS DRAWINGS

Drawing 9

435

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

LUCIFER EPP4 COMFORT 1" & 2" ATEX


REFERENCES
Codes

Pipe

Max inlet pressure


(bar)

Pressure range
(bar)

Control signal
(see options)

Dimensional
Drawing

P4CG6161C001

G1

12

10

0-10 V

11

P4CG6161C002

G1

12

10

4-20 mA

11

P4CG9161C001

G2

12

10

0-10 V

12

P4CG9161C002

G2

12

10

4-20 mA

12

Other specific settings or specialties are available, please contact us.

436

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

LUCIFER EPP4 COMFORT 1" & 2" ATEX


DIMENSIONS DRAWINGS EPP4 COMFORT RANGE 1"

Drawing 11

DIMENSIONS DRAWINGS EPP4 COMFORT


RANGE 2"

Drawing 12

437

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

LUCIFER EPP4 ACCESSORIES


MOUNTING BRACKETS FOR EPP4 1/4" BASIC / COMFORT

This mounting bracket is delivered as a standard with all EPP4 1/4''.


438

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

LUCIFER EPP4 ACCESSORIES


MOUNTING BRACKETS FOR EPP4 1/2" BASIC / COMFORT

Order reference 491367

Order reference 491366


439

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

LUCIFER EPP4 ACCESSORIES


POWER SUPPLY/CONTROL SIGNAL CABLE
FOR BASIC AND COMFORT VERSIONS.

Cable for Basic EPP4


O

2 m cable with moulded straight M12-4 pole

Order Ref. P8L-MC04A2A-M12

Cable for Comfort EPP4


O

2 m cable with moulded straight M12-8 pole

Order Reference 496796

440

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

LUCIFER EPP4 COMFORT ACCESSORIES


SOFTWARE
Calys is a unique software
in house developed to
configurate all the parameters
of the EPP4 Comfort range.
Calys is an option of the EPP4.
A specific cable is needed for
the communication between
the EPP4 and a PC.
Calys offers many capabilities:
O

Live monitoring (control


signal, regulated pressure,
supply voltage,)

Recording of the main


parameters (control signal,
regulated pressure, supply
voltage,) in an Excel file

Free calibration for


the inputs and outputs

Adjustable alarm (positivenegative, pressure limits,


delays)

Configuration files easy


to duplicate

Complete and interactive help


file

Data in 4 different

pressure units
O

Menus in 4 languages
(English, German, French
and Italian)
Specific communication cable PC-EPP4
with RS232 and USB connection
Order Reference 496449
This option is for safe area only.

To download free Calys software click on


www.parker.com/FCDE/Support
441

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EPP4 Series

LUCIFER EPP4 COMFORT ACCESSORIES


REMOTE DISPLAY
This option includes the Remote Display
and 1.5 meter connecting cable.
Connected to the pressure regulator,
it offers flexible monitoring.
Compact and highly readable remote
LED display:
O

Bar and PSI scales

Security lock

1.5 m cable

Mounting brackets

Order the Remote Display


under reference 496490
This option is for safe area only.

PANEL MOUNTING KIT


2-M3

26.6
30

19

(10)

30

20

15

23

1155

Order the Panel Mounting


Kit under reference 496610
442

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS, HOUSINGS & ELECTRICAL PARTS

A COMPLETE RANGE OF COILS, HOUSINGS


AND ELECTRICAL PARTS FOR SOLENOID VALVES

443

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS, HOUSINGS
& ELECTRICAL
PARTS

DEFINITIONS
HOUSINGS OR COIL ASSEMBLY KITS,
COILS AND ELECTRICAL PARTS

Housing:

We define a housing as the combination of the fixing elements


including the nameplate
, the cover
or the subplate
and
the envelope itself
or
which protects the coil and its electrical
components. The housings may be made of metal or plastic material.

Coil assembly kit:

The coil assembly kit


or
is the set comprising a plate, washer
and nut. Sometimes coil assembly kits consist only of a nut or a
special fixing device.

Coil:
This consists of the winding and its plastic moulding. There are three
different types of coils distinguished by their shape and dimensions:
40 mm
, 32 mm
and 22 mm
.

Electric part:
The electric part is the set comprising the housing, the assembly kit
and the coil.

Attention:
Any Lucifer coil or electrical part may be energised only when mounted on a valve.
Otherwise there is a risk of damaging the product and its surroundings (overheating, explosion, fire, etc.).

444

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS, HOUSINGS
& ELECTRICAL
PARTS

TABLE OF CONTENT
INTRODUCTION
Index by Coil Reference................................................................................................................................................................................. 446
Index by Coil Group ......................................................................................................................................................................................... 448
Index for Explosion Proof Electrical Parts............................................................................................................................................. 450
List of Coil Groups ............................................................................................................................................................................................ 451

COILS
Coils for DIN plug connection ..................................................................................................................................................................... 454
Coils with flying leads...................................................................................................................................................................................... 477
Coils with screw terminal............................................................................................................................................................................... 482
Coils with ISO-DIN connector..................................................................................................................................................................... 488

EXPLOSION PROOF ELECTRICAL PARTS


Level of protection "nc AC

.......................................................................................................................................................................... 490

Level of protection "db" ................................................................................................................................................................................. 498


Level of protection "mb"................................................................................................................................................................................ 499
Level of protection "db mb"......................................................................................................................................................................... 504
Level of protection "eb" ................................................................................................................................................................................. 509
Level of protection "ia" ................................................................................................................................................................................... 513

HOUSINGS ....................................................................................................................................................................................................... 522

COIL ACCESSORIES .............................................................................................................................................................................. 526

EXPLOSIVE ENVIRONMENTS ........................................................................................................................................................ 528

COIL APPENDICES
Guidance chart for IS-Barriers.................................................................................................................................................................... 538
Table of voltage codes for coils and electrical parts ....................................................................................................................... 540
445

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS, HOUSINGS
& ELECTRICAL
PARTS

INDEX BY COIL REFERENCE


Coil
Coil
Reference Group

Designation

481000
481044
481180
481865
482605
482606
482730
482740
482870.01
483270
483371
483510
483520
483541
483580.01
483590
483764
483816
483824
484990
485100
485400
486265
488143
488553
488650.01
488660.01
488670.01
488980
490885
490890
491514

2.0/2.1

Coil with screw terminal, 40 mm

2.0/2.2

Coil with screw terminal High power, 40 mm

492070

2.0/2.1

492190

2.0/2.1

492210

9.0

492310

10.1

492335
492425
492453
492670
492912
492965.01
493640
494040

12.0

Power
DC
Pn ( W )

Power
Ambient UL Degree of
AC
Protection
Pn (W) Temperature

ATEX
or NEMA 4X
Protection (Gas)

Page

2.0/2.1

Coil with screw terminal,double frequency, H class, 40 mm

9.0

-40C to +50C

IP 44 to 67

7.0

Explosion proof intrinsically safe electrical part "ia", 50 mm

0.3 to 3.0

-40C to +65C

IP66

II 1 G Ex ia IIC T6

7.0

Explosion proof intrinsically safe electrical part "ia", 50 mm

3.0

-40C to +65C

IP67

II 1 G Ex ia IIC T6

7.0

Explosion proof intrinsically safe electrical part "ia", 50 mm

0.3 to 3.0

-40C to +65C

IP65

II 1 G Ex ia IIC T6

1.1

Coil for DIN plug connection, low power, 22 mm

2.5

2.0

-40C to +50C

7.0

Explosion proof intrinsically safe electrical part, "NEMA", 50 mm

3.0

7.0

Explosion proof intrinsically safe electrical part, "NEMA", 50 mm

3.0

2.0/2.1

Coil for DIN plug connection, 32 mm, UL


Explosion proof encapsulated electrical part "mb",
with water proof metal housing, 50mm
Explosion proof increased safety
and encapsulated electrical part "eb", 50 mm
Explosion proof increased safety
and encapsulated electrical part "eb", "Booster", 50 mm
Explosion proof increased safety
and encapsulated electrical part "eb", 50 mm
Explosion proof intrinsically safe electrical part, "NEMA", 50 mm

11.0

-40C to +50C

IP65

482
483
461
454
499
499
456
457
417
498
509
454
482
485
513
463
459
460
485
487
484
487
484
464
486
518
519
520
461
518
519
458

8.0

9.0

-40C to +65C

IP67

II 2 G Ex mb II T4 / T5

501

8.0

8.0

-40C to +50C

IP 44 to 67

14.0

-40C to +50C

IP 44 to 67

1.1

Coil for DIN plug connection, 22 mm

5.0

4.0

-40C to +50C

IP65

2.0/2.1

Coil for DIN plug connection, 32 mm

9.0

8.0

-40C to +50C

IP65

1.1

Explosion proof encapsulated electrical part "mb", 32 mm

5.0

4.0

-40C to +65C

IP65

II 2 G Ex mb II T4 / T5

1.1

Explosion proof encapsulated electrical part "mb", low power, 32 mm

2.5

2.0

-40C to +65C

IP65

II 2 G Ex mb II T4 / T5

3.0

Coil for DIN plug connection, reduced power, 32 mm

7.0

6.0

-40C to +50C

IP65

6.0

Coil for DIN plug connection, low power, 32 mm

1.6

-40C to +50C

IP65

12.0

Explosion proof intrinsically safe electrical part "ia", 50 mm

3.0

-40C to +65C

IP66

II 1 G Ex ia IIC T6

11.0

Flame proof electrical part "db", 50 mm

8.0

8.0

-40C to +80C -

IP66

II 2 G Ex db IIC T4/T5/T6

2.0/2.1

Explosion proof increased safety electrical part "eb", 50 mm

8.0

8.0

-40C to +65C

IP67

II 2 G Ex eb IIC T4

2.0/2.1

Coil for DIN plug connection, 32 mm

9.0

-40C to +50C

IP65

2.0/2.1

Coil with screw terminal, double frequency, 40 mm

9.0

-40C to +50C

IP 44 to 67

-40C to +50C

IP 44 to 67

-40C to +55C -

IP65

II 1 G Ex ia IIC T6

14.1

Coil with screw terminal, high temperature-high power, 40 mm

20.0

20.0

7.0

Explosion proof intrinsically safe electrical part "ia", 32 mm

3.0

1.1

Coil for DIN plug connection,double frequency, 22 mm

3.0

-40C to +50C

IP65

14.2

Coil for DIN plug connection, 32 mm, UL

9.0

-40C to +50C

IP65

2.2

Coil for DIN plug connection for Jet Valves, 32 mm

14.0

14.0

-40C to +50C

IP65

14.1

Coil with screw terminal, high temperature-high power, 40 mm

19.0

19.0

-40C to +50C

IP 44 to 67

4.0

Coil with screw terminal,bistable,for impulse applications, 40 mm

11.0

-40C to +50C

IP44

2.0/2.1
4.0
2.0/2.2
1.1

Coil with screw terminal,high temperature, 40 mm

8.0

8.0

-40C to +50C

IP 44 to 67

Coil with screw terminal,bistable,for impulse applications, 40 mm

13.0

-40C to +50C

IP44

Coil with screw terminal,high temperature-high power, 40 mm

14.0

14.0

-40C to +50C

IP 44 to 67

2.5

-40C to +50C

IP65

Coil for DIN plug connection,double frequency, 22 mm

IP65

-40C to +60C -

NEMA 4 - 4X

Cl. I, Div.I, Gr. A, B, C, D

-40C to +60C -

NEMA 4 - 4X

Cl. I, Div.I, Gr. A, B, C, D

9.0

11.0

-40C to +75C -

IP66

II 2 G Ex eb mb II T3 / T4

512

1.0 to 1.8

-40C to +75C -

IP66

II 2 G Ex eb mb II T5 / T6

511

6.0

6.0

-40C to +75C -

IP66

II 2 G Ex eb mb II T4 / T5

510

3.0

-40C to +60C -

NEMA 4 - 4X

Cl. I, Div.I, Gr. A, B, C, D


-

2.0/2.1

Flame proof encapsulated electrical part "db mb", double frequency

8.0

8.0

-40C to +75C -

IP65

II 2 G Ex db mb IIC T4

2.0/2.1

Explosion proof increased safety electrical part "eb", 50 mm


Coil with ISO-DIN connector, 12-24VDC
for transportation applications, 32 mm
Explosion proof electrical part "nc AC", low power, 22 mm

8.0

8.0

-40C to +90C -

IP67

II 2 G Ex eb IIC T3 / T4

517
455
455
500
462
516
508
509

9.0

-40C to +120C -

IP69K

488

2.5

2.0

-40C to +50C

IP65

II 3 G Ex nc AC IIC T5

Explosion proof electrical part "nc AC", 32 mm

9.0

8.0

-40C to +50C

IP65

II 3 G Ex nc AC IIC T3 / T4

490
492

2.0/2.2

Coil for DIN plug connection, high temperature, 32 mm

14.0

14.0

-40C to +50C

IP65

2.0/2.1

Coil for DIN plug connection, high temperature, 32 mm

9.0

8.0

-40C to +50C

IP65

2.0/2.1

Explosion proof encapsulated electrical part "mb", 32 mm

9.0

8.0

-40C to +50C

IP65

II 2 G Ex mb II T4

1.1

Coil for DIN plug connection, 22 mm, UL

4.0

3.0

-40C to +50C

IP65

9.0

Explosion proof intrinsically safe electrical part "ia", " Booster", 50 mm 0.3 to 2.3

-40C to +65C

IP66

II 1 G Ex ia IIC T6

495294

13.0

495865
495870

1.1
2.0/2.1

446

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS, HOUSINGS
& ELECTRICAL
PARTS

INDEX BY COIL REFERENCE


Coil
Coil
Reference Group
495875
495880
495900
495905
495910
495915
496081
496082
496110
496125
496131
496155
496193

Designation

Power
DC
Pn ( W )

Power
Ambient UL Degree of
AC
Protection
Pn (W) Temperature

2.0/2.1

Explosion proof electrical part "nc AC", 32 mm

7.0

6.0

-40C to +50C

IP65

2.0/2.2

Explosion proof electrical part "nc AC", 32 mm

14.0

14.0

-40C to +50C

IP65

Flame proof encapsulated electrical part "db mb", low power, 37 mm

2.0

2.5

-40C to +65C

IP67

Flame proof encapsulated electrical part "db mb", 37 mm

8.0

8.0

-40C to +65C

IP67

0.3 to 1.2

-40C to +80C -

IP67
IP67

6.0
2.0/2.1
8.0

Explosion proof intrinsically safe electrical part "ia", "booster", 37 mm

4.0

Explosion proof increased safety electrical part "nc AC", 50 mm

13.0

11.0

-40C to +65C

2.0/2.1

Coil with ying leads,IP 67, 32 mm

9.0

9.0

-40C to +50C

2.0/2.2

Coil with ying leads, IP 67, 32 mm, UL

16.0

2.0/2.1

Explosion proof electrical part "nc AC", 32 mm

13.0-14.0 -40C to +120C

IP67

IP67

9.0

-40C to +50C

IP65
IP65

6.0

Explosion proof electrical part "nc AC", low power, 32 mm

1.6

-40C to +50C

1.2

Coil for DIN plug connection, double frequency, 22 mm

3.0

3.0

-40C to +50C

IP65

Explosion proof increased safety electrical part "nc AC", 50 mm


Coil with ISO-DIN connector, 12-24VDC,
for transportation applications, 32 mm
Coil for DIN plug connection, double frequency coil, 22 mm

14.0

14.0

-40C to +65C

IP67

Flame proof encapsulated electrical part "db mb", 37 mm

2.0/2.2
13.0

1.2
496482
10.2
496555
10.1
496560
9.0
496565
1.2
496637
10.2
496700
10.1
496800
10.1
496895
24.0
D4
24.0
D5
2.0/2.1
HZ10
2.0/2.2
HZ11
21.0
JB14
21.0
JB16
22.0
KH09
22.0
KT09
22.0
KT10
24.0
LA
24.0
LB-LC
1.3
WB4.5
1.3
WB4.5 UR
1.3
WB5.0
WB5.0
1.3
cURus
1.3
WB8.0
24.0
XS03
23.0
XT09
20.1
YB09
20.1
YB12
20.0
ZB09
20.0
ZB12
20.2
ZB14
20.2
ZB16
20.2
ZH14
20.2
ZH16

Flame proof encapsulated electrical part "db mb", 37 mm

Page

494
495
II 2 G Ex db mb IIC T4 / T5 / T6 504
II 2 G Ex db mb IIC T4
505
II 1 G Ex ia IIC T6 / T5 /T4 514
II 3 G Ex nc AC IIC T3
496
480
481
II 3 G Ex nc AC IIC T3 / T4 492
II 3 G Ex nc AC IIC T5 / T6 493
465
II 3 G Ex nc AC IIC T3
497
II 3 G Ex nc AC IIC T3 / T4
II 3 G Ex nc AC IIC T3

9.0

-40C to +120C -

IP69K

488

3.0

3.0

-40C to +50C

IP65

466

6.0

6.0

-40C to +65C

IP67

II 2 G Ex db mb IIC T4 / T5 / T6 506

-40C to +65C

506
515
II 3 D Ex TC IIIC T 95C
491
II 2 G Ex db mb IIC T4 / T5 / T6 507
II 2 G Ex db mb IIC T4
507
476
554
555
II 2 G EX mb II T4 / T5
502
II 2 G EX mb II T4 / T5
503
470
470
471
471
471
478
479
467
467
467

8.0

8.0

0.77 to 2.58

IP67

-40C to +80C -

IP67

Explosion proof electrical part "nc AC", double frequency, 22 mm

3.0

Flame proof encapsulated electrical part "db mb", 37 mm

6.0

3.0

-40C to +50C

IP65

6.0

-40C to +65C

Flame proof encapsulated electrical part "db mb", 37 mm

IP67

8.0

8.0

-40C to +65C

IP67

Coil for DIN plug connection for oil and gas, 37 mm

8.0

8.0

-40C to +50C

IP65

Coil for DIN plug connection, 32 mm, UL

16.0

13.0

-40C to +50C

IP65

Coil for DIN plug connection, 32 mm

9.0

8.0

-40C to +50C

IP65
IP65

Explosion proof intrinsically safe electrical part "ia", " Booster", 37 mm

ATEX
or NEMA 4X
Protection (Gas)

Explosion proof encapsulated electrical part "mb", double frequency

8.0

8.0

-40C to +50C

Explosion proof encapsulated electrical part "mb", double frequency

14.0

14.0

-40C to +50C

IP65

Coil for DIN plug connection

16.0

-10C to +50C

IP65

Coil for DIN plug connection

14.0

-10C to +50C

IP65

Coil for DIN plug connection

9.0

-10C to +80C -

IP65

Coil for DIN plug connection

9.0

-10C to +50C

IP65

Coil for DIN plug connection

10.0

-10C to +50C

IP65

Coil with ying leads, IP67, 32 mm

9.0

9.0

-10C to +50C

IP67

Coil with ying leads, 32 mm, UL

16.0

13.0-14.0 -10C to +50C

II 2 G Ex db mb IIC T4

II 1 G Ex ia IIC T6 / T5 / T4

IP67

4.5

-10C to +50C

IP65

Coil for DIN plug connection, 22 mm

4.5

-10C to +50C

IP65

Coil for DIN plug connection, 22 mm

5.0

-10C to +50C

IP65

Coil for DIN plug connection, 22 mm

5.0

-10C to +50C

IP65

467

Coil for DIN plug connection, 22 mm

8.0

-10C to +50C

IP65

Coil for DIN plug connection, 32 mm

9.0

-40C to +50C

IP65

Coil for DIN plug connection

9.0

-10C to +50C

IP54

Coil with ying leads, IP67, UL for AC

9.0

-10C to +50C

IP67

12.0

-10C to +50C

IP67

9.0

-10C to +50C

IP65

467
475
472
477
477
468
468
469
469
469
469

Coil for DIN plug connection, 22 mm

Coil with ying leads, IP67


Coil for DIN plug connection, UL for AC
Coil for DIN plug connection

12.0

-10C to +50C

IP65

Coil for DIN plug connection, high power - high temperature series

14.0

-10C to +50C

IP65

Coil for DIN plug connection, high power - high temperature series

16.0

-10C to +50C

IP65

Coil for DIN plug connection, high power - high temperature series

14.0

-10C to +80C -

IP65

Coil for DIN plug connection, high power - high temperature series

16.0

-10C to +80C -

IP65

447

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS, HOUSINGS
& ELECTRICAL
PARTS

INDEX BY COIL GROUP


Coil
Coil
Designation
Group Reference

Power
DC
Pn ( W )

Power
Ambient UL Degree of
AC
Protection
Pn (W) Temperature

ATEX
or NEMA 4X
Protection (Gas)

Page

Explosion proof encapsulated electrical part "mb", 32 mm

9.0

8.0

-40C to +50C

IP65

II 2 G Ex mb II T4

461
462
462
464
463
490
499
499
465
466
491
467
467
467
467
467
482
484
454
455
480
481
454
482
486
458
494
492
492
500

2.0/2.1

492070

Explosion proof encapsulated electrical part "mb",


with water proof metal housing, 50 mm

8.0

9.0

-40C to +65C

IP67

II 2 G Ex mb II T4 / T5

501

2.0/2.1
2.0/2.1
2.0/2.1
2.0/2.1

493640

Flame proof encapsulated electrical part "db mb", double frequency

8.0

8.0

-40C to +75C -

IP65

II 2 G Ex db mb IIC T4

495905

Flame proof encapsulated electrical part "db mb", 37 mm

8.0

8.0

-40C to +65C

IP67

II 2 G Ex db mb IIC T4

494040

Explosion proof increased safety electrical part "eb", 50 mm

8.0

8.0

-40C to +90C -

IP67

II 2 G Ex eb IIC T3 / T4

483371

8.0

8.0

-40C to +65C

IP67

II 2 G Ex eb IIC T4

2.0/2.1

492190

Explosion proof increased safety electrical part "eb", 50 mm


Explosion proof increased safety
and encapsulated electrical part "eb", 50 mm

508
505
509
509

9.0

11.0

-40C to +75C -

IP66

II 2 G Ex eb mb II T3 / T4

512

2.0/2.2
2.0/2.2
2.0/2.2
2.0/2.2
2.0/2.2
2.0/2.1
2.0/2.2
2.2
3.0
4.0
4.0
4.0

486265

Coil with screw terminal,high temperature-high power, 40 mm

14.0

14.0

-40C to +50C

IP 44 to 67

492425

Coil for DIN plug connection, high temperature, 32 mm

14.0

14.0

-40C to +50C

IP65

481044

Coil with screw terminal High power, 40 mm

14.0

-40C to +50C

IP 44 to 67

495880

Explosion proof electrical part "nc AC", 32 mm

14.0

14.0

-40C to +50C

IP65

II 3 G Ex nc AC IIC T3
II 3 G Ex nc AC IIC T3

484
455
483
495
497
502
503
460
456
487
487
496

488980
1.1
492912
1.1
481180
1.1
488143
1.1
483590
1.1
495865
1.1
482606
1.1
482605
1.1
496131
1.2
496482
1.2
496637
1.2
WB5.0
1.3
1.3 WB5.0 cURus
WB4.5
1.3
WB4.5 UR
1.3
WB8.0
1.3
2.0/2.1 481000
2.0/2.1 485100
2.0/2.1 481865
2.0/2.1 492453
2.0/2.1 496081
2.0/2.2 496082
2.0/2.1 483510
2.0/2.1 483520
2.0/2.1 488553
2.0/2.1 491514
2.0/2.1 495875
2.0/2.1 495870
2.0/2.1 496110
2.0/2.1 492670

496155

Coil for DIN plug connection, low power,22 mm

2.5

2.0

-40C to +50C

IP65

Coil for DIN plug connection, UL 22 mm

4.0

3.0

-40C to +50C

IP65

Coil for DIN plug connection, 22 mm

5.0

4.0

-40C to +50C

IP65

Coil for DIN plug connection,double frequency, 22 mm

2.5

-40C to +50C

IP65

Coil for DIN plug connection,double frequency, 22 mm

3.0

-40C to +50C

IP65

2.5

2.0

-40C to +50C

IP65

II 3 G Ex nc AC IIC T5

Explosion proof electrical part "nc AC", low power, 22 mm


Explosion proof encapsulated electrical part "mb", low power, 32 mm

2.5

2.0

-40C to +65C

IP65

II 2 G Ex mb II T4 / T5

Explosion proof encapsulated electrical part "mb", 32 mm

5.0

4.0

-40C to +65C

IP65

II 2 G Ex mb II T4 / T5

Coil for DIN plug connection, double frequency, 22 mm

3.0

3.0

-40C to +50C

IP65

Coil for DIN plug connection,double frequency coil, 22 mm

3.0

3.0

-40C to +50C

IP65

Explosion proof electrical part "nc AC", 22 mm, double frequency

3.0

3.0

-40C to +50C

IP65

II 3 D Ex tc IIIC T 95C

Coil for DIN plug connection, 22 mm

5.0

-10C to +50C

IP65

Coil for DIN plug connection, 22 mm

5.0

-10C to +50C

IP65

Coil for DIN plug connection, 22 mm

4.5

-10C to +50C

IP65

Coil for DIN plug connection, 22 mm

4.5

-10C to +50C

IP65

Coil for DIN plug connection, 22 mm

8.0

-10C to +50C

IP65

Coil with screw terminal, 40 mm

8.0

8.0

-40C to +50C

IP 44 to 67

Coil with screw terminal,high temperature, 40 mm

8.0

8.0

-40C to +50C

IP 44 to 67

Coil for DIN plug connection, 32 mm

9.0

8.0

-40C to +50C

IP65

Coil for DIN plug connection, high temperature, 32 mm

9.0

8.0

-40C to +50C

IP65

Coil with ying leads, IP 67, 32 mm

9.0

9.0

-40C to +50C

IP67

Coil with ying leads,IP 67, 32 mm, UL

16.0

IP67

13.0-14.0 -40C to +120C

Coil for DIN plug connection, 32 mm

9.0

-40C to +50C

IP65

Coil with screw terminal, double frequency, 40 mm

9.0

-40C to +50C

IP 44 to 67

Coil with screw terminal,double frequency, H class, 40 mm

9.0

-40C to +50C

IP 44 to 67

Coil for DIN plug connection, 32 mm, UL

11.0

-40C to +50C

IP65

Explosion proof electrical part "nc AC", 32 mm

7.0

6.0

-40C to +50C

IP65

II 3 G Ex nc AC IIC T3 / T4

Explosion proof electrical part "nc AC", 32 mm

9.0

8.0

-40C to +50C

IP65

II 3 G Ex nc AC IIC T3 / T4

Explosion proof electrical part "nc AC", 32 mm

9.0

-40C to +50C

IP65

II 3 G Ex nc AC IIC T3 / T4

Explosion proof increased safety electrical part "nc AC", 50 mm

14.0

14.0

-40C to +65C

IP67

HZ10

Explosion proof encapsulated electrical part "mb", double frequency

8.0

8.0

-40C to +50C

IP65

II 2 G Ex mb II T4 / T5

HZ11

Explosion proof encapsulated electrical part "mb", double frequency

14.0

14.0

-40C to +50C

IP65

II 2 G Ex mb II T4 / T5

483816

Coil for DIN plug connection for Jet Valves, 32 mm

14.0

14.0

-40C to +50C

IP65

482730

Coil for DIN plug connection, reduced power, 32 mm

7.0

6.0

-40C to +50C

IP65

485400

Coil with screw terminal,bistable, for impulse applications, 40 mm

13.0

-40C to +50C

IP44

484990

Coil with screw terminal,bistable, for impulse applications, 40 mm

11.0

-40C to +50C

IP44

495915

Explosion proof increased safety electrical part "nc AC", 50 mm

13.0

11.0

-40C to +65C

IP67

II 3 G Ex nc AC IIC T3

448

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS, HOUSINGS
& ELECTRICAL
PARTS

INDEX BY COIL GROUP


Coil
Coil
Designation
Group Reference
6.0
6.0
6.0
7.0
7.0
7.0
7.0
7.0
7.0
8.0

Power
DC
Pn ( W )

Power
Ambient UL Degree of
AC
Protection
Pn (W) Temperature

482740

Coil for DIN plug connection, low power, 32 mm

1.6

-40C to +50C

496125

Explosion proof electrical part "nc AC", low power, 32 mm

1.6

-40C to +50C

495900

-40C to +65C

Flame proof encapsulated electrical part "db mb", low power, 37 mm

2.0

2.5

483580.01

Explosion proof intrinsically safe electrical part "ia", 32 mm

3.0

-40C to +55C -

488660.01

Explosion proof intrinsically safe electrical part "ia", 50 mm

3.0

-40C to +65C

488650.01

Explosion proof intrinsically safe electrical part "ia", 50 mm

0.3 to 3.0

-40C to +65C

Explosion proof intrinsically safe electrical part "ia", 50 mm

488670.01

ATEX
or NEMA 4X
Protection (Gas)

Page

457
490
IP67
II 2 G Ex db mb IIC T4 / T5 / T6 504
IP65
II 1 G Ex ia IIC T6
513
IP67
II 1 G Ex ia IIC T6
519
IP66
II 1 G Ex ia IIC T6
518
IP65
II 1 G Ex ia IIC T6
520
NEMA 4 - 4X
Cl. I, Div.I, Gr. A, B, C, D
518
NEMA 4 - 4X
Cl. I, Div.I, Gr. A, B, C, D
519
IP67
II 1 G Ex ia IIC T6 / T5 /T4
514
IP65

IP65

II 3 G Ex nc AC IIC T5 / T6

0.3 to 3.0

-40C to +65C

490885

Explosion proof intrinsically safe electrical part, "NEMA", 50 mm

3.0

-40C to +60C -

490890

Explosion proof intrinsically safe electrical part, "NEMA", 50 mm

3.0

-40C to +60C -

495910

Explosion proof intrinsically safe electrical part "ia", "booster", 37 mm 0.3 to 1.2.0

-40C to +80C -

9.0

492210

-40C to +75C -

IP66

II 2 G Ex eb mb II T5 / T6

511

9.0
9.0
10.1
10.1
10.1

496565

Explosion proof increased safety


1.0 to 1.8
and encapsulated electrical part "eb", " Booster", 50 mm
Explosion proof intrinsically safe electrical part "ia", " Booster", 37 mm 0.77 to 2.58

-40C to +80C -

IP67

II 1 G Ex ia IIC T6 / T5 / T4

492965.01

Explosion proof intrinsically safe electrical part "ia", " Booster", 50 mm 0.3 to 2.3

-40C to +65C

IP66

II 1 G Ex ia IIC T6

8.0

8.0

-40C to +65C

IP67

II 2 G Ex db mb IIC T4

10.1

492310

Flame proof encapsulated electrical part "db mb", 37 mm


Explosion proof increased safety
and encapsulated electrical part "eb", 50 mm

515
516
476
506
507

6.0

6.0

-40C to +75C -

IP66

II 2 G Ex eb mb II T4 / T5

510

10.2
10.2
11.0
12.0
12.0

496555

Flame proof encapsulated electrical part "db mb", 37 mm

6.0

6.0

-40C to +65C

IP67

II 2 G Ex db mb IIC T4 / T5 / T6 506

496700

Flame proof encapsulated electrical part "db mb", 37 mm

6.0

6.0

-40C to +65C

IP67

II 2 G Ex db mb IIC T4 / T5 / T6 507

483270

Flame proof electrical part "db", 50 mm

8.0

8.0

-40C to +80C -

IP66

II 2 G Ex db IIC T4/T5/T6

Explosion proof intrinsically safe electrical part "ia", 50 mm

3.0

-40C to +65C

IP66

II 1 G Ex ia IIC T6

496895

Coil for DIN plug connection for oil and gas, 37 mm

8.0

8.0

-40C to +50C

IP65

496560

Flame proof encapsulated electrical part "db mb", 37 mm

8.0

8.0

-40C to +65C

IP67

II 2 G Ex db mb IIC T4

496800

492335

Explosion proof intrinsically safe electrical part, "NEMA", 50 mm

3.0

-40C to +60C -

NEMA 4 - 4X

Cl. I, Div.I, Gr. A, B, C, D

498
517
517

13.0

495294

9.0

-40C to +120C -

IP69K

488

13.0

496193

Coil with ISO-DIN connector, 12-24VDC


for transportation applications, 32 mm
Coil with ISO-DIN connector, 12-24VDC
for transportation applications, 32 mm

9.0

-40C to +120C -

IP69K

488

14.1
14.1
14.2
20.0
20.0
20.1
20.1
20.2
20.2
20.2
20.2
21.0
21.0
22.0
22.0
22.0
23.0
24.0
24.0
24.0
24.0
24.0

483824

Coil with screw terminal, high temperature-high power, 40 mm

19.0

19.0

-40C to +50C

IP 44 to 67

483541

Coil with screw terminal, high temperature-high power, 40 mm

20.0

20.0

-40C to +50C

IP 44 to 67

483764

Coil for DIN plug connection, 32 mm, UL

485
485
459
468
468
477
477
469
469
469
469
470
470
471
471
471
472
474
478
473
479
475

482870.01

ZB12

Coil for DIN plug connection

ZB09

Coil for DIN plug connection, UL for AC

YB12

Coil with ying leads, IP67

YB09

Coil with ying leads, IP67, UL for AC

9.0

-40C to +50C

IP65

12.0

-10C to +50C

IP65

9.0

-10C to +50C

IP65

12.0

-10C to +50C

IP67

9.0

-10C to +50C

IP67

ZB16

Coil for DIN plug connection, high power -high temperature series

16.0

-10C to +50C

IP65

ZH16

Coil for DIN plug connection, high power -high temperature series

16.0

-10C to +80C -

IP65

ZB14

Coil for DIN plug connection, high power -high temperature series

14.0

-10C to +50C

IP65

ZH14

Coil for DIN plug connection, high power -high temperature series

14.0

-10C to +80C -

IP65

JB14

Coil for DIN plug connection

16.0

-10C to +50C

IP65

JB16

Coil for DIN plug connection

14.0

-10C to +50C

IP65

KT10

Coil for DIN plug connection

10.0

-10C to +50C

IP65

KH09

Coil for DIN plug connection

9.0

-10C to +80C -

IP65

KT09

Coil for DIN plug connection

9.0

-10C to +50C

IP65

XT09

Coil for DIN plug connection

9.0

-10C to +50C

IP54

D5

Coil for DIN plug connection, 32 mm

9.0

8.0

-40C to +50C

IP65

LA

Coil with ying leads, IP67, 32 mm

9.0

9.0

-10C to +50C

IP67

D4

Coil for DIN plug connection, 32 mm, UL

16.0

13.0

-40C to +50C

IP65

LB-LC

Coil with ying leads, IP 67, 32 mm, UL

16.0

IP67

XS03

Coil for DIN plug connection, 32 mm

IP65

449

13.0-14.0 -10C to +50C


9.0

-40C to +50C

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS, HOUSINGS
& ELECTRICAL
PARTS

INDEX FOR EXPLOSION PROOF ELECTRICAL PARTS


Coil
Coil Designation
Reference Group
496637

Power
DC
Pn ( W )

Power
Ambient UL Degree of
AC
Protection
Pn (W) Temperature

ATEX
or NEMA 4X
Protection (Gas)

Page

3.0

3.0

-40C to +50C

IP65

II 3 D Ex tc IIIC T 95C

491

495880

2.0/2.2 Explosion proof electrical part "nc AC", 32 mm

14.0

14.0

-40C to +50C

IP65

II 3 G Ex nc AC IIC T3

495

496155

2.0/2.2 Explosion proof increased safety electrical part "nc AC", 50 mm

14.0

14.0

-40C to +65C

IP67

II 3 G Ex nc AC IIC T3

497

13.0

11.0

-40C to +65C

IP67

II 3 G Ex nc AC IIC T3

496

495915

1.2

4.0

Explosion proof electrical part "nc AC", 22 mm, double frequency

Explosion proof increased safety electrical part "nc AC", 50 mm

495870

2.0/2.1 Explosion proof electrical part "nc AC", 32 mm

9.0

8.0

-40C to +50C

IP65

II 3 G Ex nc AC IIC T3 / T4

492

495875

2.0/2.1 Explosion proof electrical part "nc AC", 32 mm

7.0

6.0

-40C to +50C

IP65

II 3 G Ex nc AC IIC T3 / T4

494

496110

2.0/2.1 Explosion proof electrical part "nc AC", 32 mm

9.0

-40C to +50C

IP65

II 3 G Ex nc AC IIC T3 / T4

492

495865

1.1

Explosion proof electrical part "nc AC", low power, 22 mm

2.5

2.0

-40C to +50C

IP65

II 3 G Ex nc AC IIC T5

490

496125

6.0

Explosion proof electrical part "nc AC", low power, 32 mm

1.6

-40C to +50C

IP65

II 3 G Ex nc AC IIC T5 / T6

493

2.0/2.1 Explosion proof encapsulated electrical part "mb", 32 mm

9.0

8.0

-40C to +50C

IP65

II 2 G Ex mb II T4

500

492670
482605

1.1

Explosion proof encapsulated electrical part "mb", 32 mm

5.0

4.0

-40C to +65C

IP65

II 2 G Ex mb II T4 / T5

498

482606

1.1

Explosion proof encapsulated electrical part "mb", low power, 32 mm

2.5

2.0

-40C to +65C

IP65

II 2 G Ex mb II T4 / T5

498

492070

proof encapsulated electrical part "mb",


2.0/2.1 Explosion
with water proof metal housing, 50 mm

8.0

9.0

-40C to +65C

IP67

II 2 G Ex mb II T4 / T5

501

HZ10

2.0/2.1 Explosion proof encapsulated electrical part "mb", double frequency

8.0

8.0

-40C to +50C

IP65

II 2 G Ex mb II T4 / T5

502

HZ11

2.0/2.2 Explosion proof encapsulated electrical part "mb", double frequency

14.0

14

-40C to +50C

IP65

II 2 G Ex mb II T4 / T5

503

8.0

8.0

-40C to +80C -

IP66

II 2 G Ex db IIC T4/T5/T6

498

483270

11.0

Flame proof electrical part "db", 50 mm

493640

2.0/2.1 Flame proof encapsulated electrical part "db mb", double frequency

8.0

8.0

-40C to +75C -

IP65

II 2 G Ex db mb IIC T4

508

495905

2.0/2.1 Flame proof encapsulated electrical part "db mb", 37 mm

8.0

8.0

-40C to +65C

IP67

II 2 G Ex db mb IIC T4

505

496560

10.1

Flame proof encapsulated electrical part "db mb", 37 mm

8.0

8.0

-40C to +65C

IP67

II 2 G Ex db mb IIC T4

506

496800

10.1

Flame proof encapsulated electrical part "db mb", 37 mm

8.0

8.0

-40C to +65C

IP67

II 2 G Ex db mb IIC T4

507

495900

6.0

Flame proof encapsulated electrical part "db mb", low power, 37 mm

2.0

2.5

-40C to +65C

IP67

II 2 G Ex db mb IIC T4 / T5 / T6 504

496555

10.2

Flame proof encapsulated electrical part "db mb", 37 mm

6.0

6.0

-40C to +65C

IP67

II 2 G Ex db mb IIC T4 / T5 / T6 506

496700

10.2

Flame proof encapsulated electrical part "db mb", 37 mm

6.0

6.0

-40C to +65C

IP67

II 2 G Ex db mb IIC T4 / T5 / T6 507

494040

2.0/2.1 Explosion proof increased safety electrical part "eb", 50 mm

8.0

8.0

-40C to +90C -

IP67

II 2 G Ex eb IIC T3 / T4

509

483371

2.0/2.1 Explosion proof increased safety electrical part "eb", 50 mm

8.0

8.0

-40C to +65C

IP67

II 2 G Ex eb IIC T4

509

492190

proof increased safety


2.0/2.1 Explosion
and encapsulated elect. part "eb", 50 mm
proof increased safety
10.1 Explosion
and encapsulated electrical part "eb", 50 mm
Explosion proof increased safety
9.0
and encapsulated electrical part "eb", " Booster", 50 mm

9.0

11.0

-40C to +75C -

IP66

II 2 G Ex eb mb II T3 / T4

512

492310
492210

6.0

6.0

-40C to +75C -

IP66

II 2 G Ex eb mb II T4 / T5

510

1.0 to 1.8

-40C to +75C -

IP66

II 2 G Ex eb mb II T5 / T6

511

0.3 to 1.2

-40C to +80C -

IP67

II 1 G Ex ia IIC T6 / T5 /T4

514

495910

8.0

Explosion proof intrinsically safe electrical part "ia", "booster", 37 mm

496565

9.0

Explosion proof intrinsically safe electrical part "ia", " Booster", 37 mm 0.77 to 2.58

-40C to +80C -

IP67

II 1 G Ex ia IIC T6 / T5 / T4

515

483580.01

7.0

Explosion proof intrinsically safe electrical part "ia", 32 mm

3.0

-40C to +55C -

IP65

II 1 G Ex ia IIC T6

513

488650.01

7.0

Explosion proof intrinsically safe electrical part "ia", 50 mm

0.3 to 3.0

-40C to +65C

IP66

II 1 G Ex ia IIC T6

518

488660.01

7.0

Explosion proof intrinsically safe electrical part "ia", 50 mm

3.0

-40C to +65C

IP67

II 1 G Ex ia IIC T6

519

488670.01

7.0

0.3 to 3

-40C to +65C

IP65

II 1 G Ex ia IIC T6

520

492965.01

9.0

0.3 to 2.3

-40C to +65C

IP66

II 1 G Ex ia IIC T6

516

482870.01

12.0

Explosion proof intrinsically safe electrical part "ia", 50 mm


Explosion proof intrinsically safe electrical part "ia", " Booster", 50
mm
Explosion proof intrinsically safe electrical part "ia", 50 mm

3.0

-40C to +65C

IP66

II 1 G Ex ia IIC T6

517

490885

7.0

Explosion proof intrinsically safe electrical part, "NEMA", 50 mm

3.0

-40C to +60C -

NEMA 4 - 4X

Cl. I, Div.I, Gr. A, B, C, D

518

490890

7.0

Explosion proof intrinsically safe electrical part, "NEMA", 50 mm

3.0

-40C to +60C -

NEMA 4 - 4X

Cl. I, Div.I, Gr. A, B, C, D

519

492335

12.0

Explosion proof intrinsically safe electrical part, "NEMA", 50 mm

3.0

-40C to +60C -

NEMA 4 - 4X

Cl. I, Div.I, Gr. A, B, C, D

517

450

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS, HOUSINGS
& ELECTRICAL
PARTS

LIST OF COIL GROUPS


Parker coils and electrical parts are classified by groups determining their compatibility with Parker solenoid
valves.

Group

For application with

1.1

Standard valves or on 2000 Series with standard pilot

1.2

Standard valves or on 2000 Series for high ow

1.3

Standard valves or on 2000 Series of W coil

2.0

Standard valves or on 7000 Series with standard pilot

2.1

Standard valves or on 7000 Series, for coils 8 - 9 W

2.2

Standard valves or on 7000 Series, for coils 14 W

3.0

Standard valves or on 7000 Series with reduced power

4.0

Standard valves or on 7000 Series, for bistable (Impulse) coils or electrical parts

6.0

Special valves "97" or on 7000 Series, for Intrinsicaly safe coils or electrical parts

7.0

Special valves "90", for coils and intrinsically safe electrical parts

8.0

Special valves "97" or on 7000 Series, for Intrinsicaly safe coils or electrical parts with booster

9.0

Special valves "xx" or on 9000 Series, for Intrinsicaly safe coils or electrical parts with booster

10.1

Standard valves or on 9000 Series with standard pilot

10.2

Standard valves or on 9000 Series "db mb"

11.0

Standard valves or on 9000 Series "1D"

12.0

Standard valves or on 9000 Series with manual reset

13.0

Special valves or on 7000 Series for Transportation

14.1

Special valves or on 7000 Series for Oil Burners

14.2

Special valves or on 7000 Series for Oil Burners

20.1

Standard valves or on 7000 Series for Z-Y coil

20.2

Standard valves or on 7000 Series for Z-Y "High Power" coil

21.0

Standard valves or on 7000 Series for J-B coil

22.0

Standard valves for KP-KT-KH coil

23.0

Standard valves for XP-XT coil for Oil Burners

24.0

Standard valves for Liquipure coils for Beverage Dispensing

451

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS

452

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS

TABLE OF CONTENT
INTRODUCTION
Index by Coil Reference................................................................................................................................................................................. 446
Index by Coil Group ......................................................................................................................................................................................... 448
Index for Explosion Proof Electrical Parts............................................................................................................................................. 450
List of Coil Groups ............................................................................................................................................................................................ 451

COILS
Coils for DIN plug connection ..................................................................................................................................................................... 454
Coils with flying leads...................................................................................................................................................................................... 477
Coils with screw terminal............................................................................................................................................................................... 482
Coils with ISO-DIN connector..................................................................................................................................................................... 488

EXPLOSION PROOF ELECTRICAL PARTS


Level of protection "nc AC

.......................................................................................................................................................................... 490

Level of protection "db" ................................................................................................................................................................................. 498


Level of protection "mb"................................................................................................................................................................................ 499
Level of protection "db mb"......................................................................................................................................................................... 504
Level of protection "eb" ................................................................................................................................................................................. 509
Level of protection "ia" ................................................................................................................................................................................... 513

HOUSINGS ....................................................................................................................................................................................................... 522

COIL ACCESSORIES .............................................................................................................................................................................. 526

EXPLOSIVE ENVIRONMENTS ........................................................................................................................................................ 528

COIL APPENDICES
Guidance chart for IS-Barriers.................................................................................................................................................................... 538
Table of voltage codes for coils and electrical parts ....................................................................................................................... 540
453

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

2.0/2.1

COILS FOR
DIN PLUG CONNECTION

COILS 32 mm
These coils can be mounted with every Parker solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
This is an encapsulated assembly comprising a coil, integral
magnetic iron path and snap-on plug connection.
The synthetic material encapsulation provides an effective compact
housing, offering full protection against dust, oil, water, etc.
Ease of mounting in confined space - offers shock and corrosion
protection - simplifies conversion of existing equipment to other
requirements, etc.
Coils conform to the IEC/CENELEC safety standards and complies with
European low-voltage directive.
Specication

Standard
481865
482725

Ref. (without DIN plug)


Ref. (with DIN plug)
Coil Group
Degree of protection
Class of insulation
Electrical connection

2.0 / 2.1

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of the Un

Double frequency
483510
482635

VAC/Hz
24/50
48/50
110/50
220-230/50

IP65 according to IEC / EN 60529 standards (with DIN plug).


F 155C
The coil is connected with a 2 P + E plug according to EN 175301-803 type A
-40C to +50C
The application is limited also by the temperature range of the valve.
9W
12 W
8W
9W
26 VA (9 W)
32 VA (10 W)
130 g (without plug)
Code
VDC
Code
VAC/Hz
A2
A4
A5
3D

24
48
110

C2
C4
C5

24/50, 24/60
48/50, 48/60
110-115/50, 120/60
220-240/50, 240/60

Code
P0
S4
S5
S6

To Order a Coil choose Coil Ref + Voltage Code, example: 481865 for 24 VDC = 481865C2
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

These coils must be used with


suitable housings, see example
below:
The coil assembly kit Ref. 2995
corresponds to the "housing" of
Lucifer valve numbering system
(Valve - housing - coil - voltage).
It is composed of a nameplate
giving details of the valve type,
a round washer and a nut
to ensure the fixing between
32 mm coil and the valve.
454

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

2.0/2.1
2.2

COILS FOR
DIN PLUG CONNECTION

HIGH TEMPERATURE COILS 32 mm


These coils can be mounted with every Parker solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
This is an encapsulated assembly comprising a coil, integral
magnetic iron path and snap-on plug connection.
The synthetic material encapsulation provides an effective compact
housing, offering full protection against dust, oil, water, etc.
Ease of mounting in confined space - offers shock and corrosion
protection - simplifies conversion of existing equipment to other
requirements, etc.
Coils conform to the IEC/CENELEC safety standards and complies with
European low-voltage directive.
Specication
Ref. (without DIN plug)
Ref. (with DIN plug)
Coil Group
Degree of protection
Class of insulation
Electrical connection

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of the Un

VAC/Hz
24/50
48/50
110/50
220/50-230/50

High temperature

High temp. + high power

492453
492726

492425
492727

2.0 / 2.1

2.0 / 2.2

IP65 according to IEC / EN 60529 standards (with DIN plug).


H 180C
The coil is connected with a 2 P + E plug according to EN 175301-803 type A
-40C to +50C
The application is limited also by the temperature range of the valve.
9W
14 W
12 W
21 W
8W
14 W
26 VA (9 W)
55 VA (18 W)
130 g (without plug)
Code
VDC
Code
VAC/Hz
Code
VDC
A2
A4
A5
3D

24

C2

24/50
110/50
230/50

A2
A5
F4

24

Code
C2

To Order a Coil choose Coil Ref + Voltage Code, example: 492453 for 24VDC= 492453C2
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

These coils must be used with


suitable housings, see example
below:
The coil assembly kit Ref. 2995
corresponds to the "housing" of
Lucifer valve numbering system
(Valve - housing - coil - voltage).
It is composed of a nameplate
giving details of the valve type,
a round washer and a nut
to ensure the fixing between
32 mm coil and the valve.
455

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

3.0

COILS FOR
DIN PLUG CONNECTION

REDUCED POWER COIL 32 mm


These coils can be mounted with every Parker solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
This is an encapsulated assembly comprising a coil, integral
magnetic iron path and snap-on plug connection.
The synthetic material encapsulation provides an effective compact
housing, offering full protection against dust, oil, water, etc.
Ease of mounting in confined space - offers shock and corrosion
protection - simplifies conversion of existing equipment to other
requirements, etc.
Coils conform to the IEC/CENELEC safety standards and complies with
European low-voltage directive.
Specication

Reduced power
482730
482735
3.0

Ref. (without DIN plug)


Ref. (with DIN plug)
Coil Group
Degree of protection
Class of insulation
Electrical connection

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of the Un

VAC/Hz

IP65 according to IEC / EN 60529 standards (with DIN plug).


F 155C
The coil is connected with a 2 P + E plug according to EN 175301-803 type A
-40C to +50C
The application is limited also by the temperature range of the valve.
7W
9W
6W
20 VA (7 W)
130 g (without plug)
Code
VDC

24/50
48/50
110/50-115/50
220-230/50

A2
A4
A7
3D

24
48

Code
C2
C4

To Order a Coil choose Coil Ref + Voltage Code, example: 482730 for 24VDC = 482730C2
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

These coils must be used with


suitable housings, see example
below:
The coil assembly kit Ref. 2995
corresponds to the "housing" of
Lucifer valve numbering system
(Valve - housing - coil - voltage).
It is composed of a nameplate
giving details of the valve type,
a round washer and a nut
to ensure the fixing between
32 mm coil and the valve.
456

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

6.0

COILS FOR
DIN PLUG CONNECTION

LOW POWER COIL 32 mm


These coils can be mounted with every Parker solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
This is an encapsulated assembly comprising a coil, integral
magnetic iron path and snap-on plug connection.
The synthetic material encapsulation provides an effective compact
housing, offering full protection against dust, oil, water, etc.
Ease of mounting in confined space - offers shock and corrosion
protection - simplifies conversion of existing equipment to other
requirements, etc.
Coils conform to the IEC/CENELEC safety standards and complies with
European low-voltage directive.
Specication
Reference (without DIN plug)
Reference (with DIN plug)
Coil Group
Degree of protection
Class of insulation
Electrical connection

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of the Un

Miniwatt
482740
482745
6.0
IP65 according to IEC / EN 60529 standards (with DIN plug).
F 155C
The coil is connected with a 2 P + E plug according to EN 175301-803 type A
-40C to +50C
The application is limited also by the temperature range of the valve.
1.6 W
2.1 W
130 g (without plug)
VDC
Code
24
48
110

C2
C4
C5

To Order a Coil choose Coil Ref + Voltage Code, example: 482740 for 24VDC = 482740C2
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

These coils must be used with


suitable housings, see example
below:
The coil assembly kit Ref. 2995
corresponds to the "housing" of
Lucifer valve numbering system
(Valve - housing - coil - voltage).
It is composed of a nameplate
giving details of the valve type,
a round washer and a nut
to ensure the fixing between
32 mm coil and the valve.
457

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

2.0/2.1

COILS FOR
DIN PLUG CONNECTION

UL COIL 32 mm
This coil can be mounted with every Parker solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
This is an encapsulated assembly comprising a coil, integral
magnetic iron path and snap-on plug connection.
The synthetic material encapsulation provides an effective compact
housing, offering full protection against dust, oil, water, etc.
Ease of mounting in confined space - offers shock and corrosion
protection - simplifies conversion of existing equipment to other
requirements, etc.
Coils conform to the IEC/CENELEC safety standards and complies with
European low-voltage directive.
Specication

UL-recognized coil - UL File E125678 - designation AMIF


491514
2.0 / 2.1

Reference (without DIN plug)


Coil Group
Degree of protection
Class of insulation
Electrical connection

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
- 15% to +10% of the Un

VAC/Hz

IP65 according to IEC / EN 60529 standards (with DIN plug).


F (155C)
The coil is connected with a 2 P + E plug according to EN 175301-803 type A
-40C to 50C
The application is limited also by the temperature range of the valve.
12 W
16 W
11 W
40 VA (13 W)
130 g (without plug)
Code
VDC

110/50-120/60
220/50-240/60

P3
Q3

24

Code
C2

To Order a Coil choose Coil Ref + Voltage Code, example: 491514 for 24VDC = 491514C2
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

These coils must be used with


suitable housings, see example
below:
The coil assembly kit
Ref. 2995 with non UL valve
and Ref. 2995.03 with UL valve
correspond to the "housing" of
Lucifer valve numbering system
(Valve - housing - coil - voltage).
It is composed of a nameplate
giving details of the valve type,
a round washer and a nut
to ensure the fixing between
32 mm coil and the valve.
458

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

14.2

COILS FOR
DIN PLUG CONNECTION

UL COIL 32 mm
This coil can be mounted with every Parker solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
This is an encapsulated assembly comprising a coil, integral
magnetic iron path and snap-on plug connection.
The synthetic material encapsulation provides an effective compact
housing, offering full protection against dust, oil, water, etc.
Ease of mounting in confined space - offers shock and corrosion
protection - simplifies conversion of existing equipment to other
requirements, etc.
Coils conform to the IEC/CENELEC safety standards and complies with
European low-voltage directive.
Specication
Reference (without DIN plug)
Coil group
Degree of protection
Class of insulation
Electrical connection

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
- 15% to +10% of the Un

Coil for oil burner - UL recognized


483764
14.2
IP65 according to IEC / EN 60529 standards (with DIN plug).
F 155C
With DIN 43650 A Plug
-40C to 50C
The application is limited also by the temperature range of the valve.
9W
138 g
VAC/Hz
Code
240/50-60
110/50-115/60
230/50-240/60

Q1
Q9
T1

To Order a Coil choose Coil Ref + Voltage Code, example: 483764 for 240/50-60 = 483764Q1
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

These coils must be used with


suitable housings, see example
below:
The coil assembly kit Ref. 2995
corresponds to the "housing" of
Lucifer valve numbering system
(Valve - housing - coil - voltage).
It is composed of a nameplate
giving details of the valve type,
a round washer and a nut
to ensure the fixing between
32 mm coil and the valve.
459

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

2.2

COILS FOR
DIN PLUG CONNECTION

COIL 32 mm FOR JET VALVES


This coil can be mounted with every Parker solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
This is an encapsulated assembly comprising a coil, integral
magnetic iron path and snap-on plug connection.
The synthetic material encapsulation provides an effective compact
housing, offering full protection against dust, oil, water, etc.
Ease of mounting in confined space - offers shock and corrosion
protection - simplifies conversion of existing equipment to other
requirements, etc.
Coils conform to the IEC/CENELEC safety standards and complies with
European low-voltage directive.
Specication
Reference
Coil Group
Degree of protection
Class of insulation
Electrical connection

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of the Un

32 mm coil 14 W
483816
2.2
IP65 according to IEC / EN 60529 standards (with DIN plug).
F 155C
With DIN 43650 A Plug
-40C to +50C
The application is limited also by the temperature range of the valve.
14 W
14 W
160 g
VAC/Hz
Code
VDC
24/50
A2
24 V

Code
C2

To Order a Coil choose Coil Ref + Voltage Code, example: 483816 for 24VDC = 483816C2
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

These coils must be used with


suitable housings, see example
below:
The coil assembly kit Ref. 2995
corresponds to the "housing" of
Lucifer valve numbering system
(Valve - housing - coil - voltage).
It is composed of a nameplate
giving details of the valve type,
a round washer and a nut
to ensure the fixing between
32 mm coil and the valve.
460

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

1.1

COILS FOR
DIN PLUG CONNECTION

COILS 22 mm
These coils can be mounted with every Parker solenoid valves
corresponding to the specied Coil Group.
See column "Coil Group" within valve pages.
This coil is designed for valves equipped with a miniature tube
assembly (2000 series valves). This is an encapsulated assembly
comprising a coil, integral magnetic iron path and snap-on plug
connection.
The synthetic material encapsulation provides an effective compact
housing, offering full protection against dust, oil, water, etc.
Ease of mounting in confined space - offers shock and corrosion protection
- simplifies conversion of existing equipment to other requirements, etc.
Coil conforms to the IEC/CENELEC safety standards and complies with
European low-voltage directive.
Specication

Low power
488980
481045

Ref. (without DIN plug)


Ref. (with DIN plug)
Coil Group
Degree of protection
Class of insulation
Electrical connection

1.1

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of the Un

High power
481180
481530

VAC/Hz
24/50
48/50
110/50-115/50

IP65 according to IEC / EN 60529 standards (with DIN plug).


F 155C
The coil is connected with a 2 P + E plug according to EN 175301-803 type B.
-40C to +50C
The application is limited also by the temperature range of the valve.
2.5 W
5W
3W
6.5 W
2W
4W
5.7 VA (2.5 W)
8.9 VA (5 W)
100 g with DIN Plug
Code
VDC
Code
VAC/Hz
Code
VDC
A2
A4
0A

24
48
110

C2
C4
C5

24/50
110/50-115/50
220/50-230/50

A2
0A
3D

24

Code
C2

To Order a Coil choose Coil Ref + Voltage Code, example: 488980 for 24VDC = 488980C2
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

These coils must be used with


suitable housings, see example
below:
The coil assembly kit Ref. 8993
corresponds to the numbering
system for Lucifer valve housings
(Valve - housing - coil - voltage).
It is composed of a nameplate
with the details of the valve
type, a washer and a nut
to secure the 22 mm coil to
the valve.
461

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

1.1

COILS FOR
DIN PLUG CONNECTION

UL COIL 22 mm
These coils can be mounted with every Parker solenoid valves
corresponding to the specied Coil Group.
See column "Coil Group" within valve pages.
This coil is designed for valves equipped with a miniature tube
assembly (2000 series valves). This is an encapsulated assembly
comprising a coil, integral magnetic iron path and snap-on plug
connection.
The synthetic material encapsulation provides an effective compact
housing, offering full protection against dust, oil, water, etc.
Ease of mounting in confined space - offers shock and corrosion protection
- simplifies conversion of existing equipment to other requirements, etc.
Coil conforms to the IEC/CENELEC safety standards and complies with
European low-voltage directive.
Specication

Standard UL (only if used with 321K, 121M, 131M valves)


492912
492919
1.1

Reference (without DIN plug)


Reference (with DIN plug)
Coil Group
Degree of protection
Class of insulation
Electrical connection

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
- 15% to +10% of the Un

VAC/Hz

IP65 according to IEC / EN 60529 standards (with DIN plug).


A 105C for UL/CSA
The coil is connected with a 2 P + E plug according to EN 175301-803 type B.
-40C to +50C
The application is limited also by the temperature range of the valve.
4W
4.5 W
3W
7.5 VA (4 W)
100 g with DIN Plug
Code
VDC

24/50-24/60
48/50-48/60
115/50-120/60
230/50-240/60

P0
S4
P8
T1

24

Code
C2

To Order a Coil choose Coil Ref + Voltage Code, example: 492912 for 24VDC = 492412C2
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

These coils must be used with


suitable housings, see example
below:
The coil assembly kit Ref. 8993
corresponds to the "housing" of
Lucifer valve numbering system
(Valve - housing - coil - voltage).
It is composed of a nameplate
giving details of the valve type,
a round washer and a nut
to ensure the fixing between
32 mm coil and the valve.
462

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

1.1

COILS FOR
DIN PLUG CONNECTION

DOUBLE FREQUENCY COIL 22 mm


This coil can be mounted with every Parker solenoid valves
corresponding to the specied Coil Group.
See column "Coil Group" within valve pages.
This coil is designed for valves equipped with a miniature tube assembly
(2000 series valves). This is an encapsulated assembly comprising a
coil, integral magnetic iron path and snap-on plug connection.
The synthetic material encapsulation provides an effective compact
housing, offering full protection against dust, oil, water, etc.
Ease of mounting in confined space - offers shock and corrosion protection
- simplifies conversion of existing equipment to other requirements, etc.
Coil conforms to the IEC/CENELEC safety standards and complies with
European low-voltage directive.
DIN plug connector to be ordered separately (see coil accessories section).
Specication
Reference (without DIN plug)
Coil group
Degree of protection
Class of insulation
Electrical connection

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of the Un

Double frequency
483590
1.1
IP65 according to IEC / EN 60529 standards (with DIN plug).
F 155C
The coil is connected with a 2 P + E plug according to EN 175301-803 type B.
-40C to +50C
The application is limited also by the temperature range of the valve.
3W
7.5 VA (4 W)
100 g with DIN Plug
VAC/Hz
Code
24/50, 24/60
48/50, 48/60
110-115/50, 120/60
220-240/50, 240/60

P0
S4
S5
S6

To Order a Coil choose Coil Ref + Voltage Code, example: 483590 for 24/50,24/60 = 483590P0
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

These coils must be used with


suitable housings, see example
below:
The coil assembly kit Ref. 8993
corresponds to the "housing" of
Lucifer valve numbering system
(Valve - housing - coil - voltage).
It is composed of a nameplate
giving details of the valve type,
a round washer and a nut
to ensure the fixing between
32 mm coil and the valve.
463

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

1.1

COILS FOR
DIN PLUG CONNECTION

DOUBLE FREQUENCY COIL 22 mm


This coil can be mounted with every Parker solenoid valves
corresponding to the specied Coil Group.
See column "Coil Group" within valve pages.
This coil is designed for valves equipped with a miniature tube assembly
(2000 series valves). This is an encapsulated assembly comprising a
coil, integral magnetic iron path and snap-on plug connection.
The synthetic material encapsulation provides an effective compact
housing, offering full protection against dust, oil, water, etc.
Ease of mounting in confined space - offers shock and corrosion protection
- simplifies conversion of existing equipment to other requirements, etc.
Coil conforms to the IEC/CENELEC safety standards and complies with
European low-voltage directive.
DIN plug connector to be ordered separately (see coil accessories section).
Specication
Reference (without DIN Plug)
Coil group
Degree of protection
Class of insulation
Electrical connection

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of the Un

Double frequency
488143
1.1
IP65 according to IEC / EN 60529 standards (with DIN plug).
F 155C
The coil is connected with a 2 P + E plug according to EN 175301-803 type B.
-40C to +50C
The application is limited also by the temperature range of the valve.
2.5 W
60 g
VAC/Hz
Code
P1
P6

100/50-60
200/50-60

To Order a Coil choose Coil Ref + Voltage Code, example: 488143 for 100/50-60 = 488143P1
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

These coils must be used with


suitable housings, see example
below:
The coil assembly kit Ref. 8993
corresponds to the "housing" of
Lucifer valve numbering system
(Valve - housing - coil - voltage).
It is composed of a nameplate
giving details of the valve type,
a round washer and a nut
to ensure the fixing between
32 mm coil and the valve.
464

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

1.2

COILS FOR
DIN PLUG CONNECTION

DOUBLE FREQUENCY COIL 22 mm


This coil can be mounted with every Parker solenoid valves
corresponding to the specied Coil Group.
See column "Coil Group" within valve pages.
This coil is designed for valves equipped with a miniature tube assembly
(2000 series valves). This is an encapsulated assembly comprising a
coil, integral magnetic iron path and snap-on plug connection.
The synthetic material encapsulation provides an effective compact
housing, offering full protection against dust, oil, water, etc.
Ease of mounting in confined space - offers shock and corrosion protection
- simplifies conversion of existing equipment to other requirements, etc.
Coil conforms to the IEC/CENELEC safety standards and complies with
European low-voltage directive.
DIN plug connector to be ordered separately (see coil accessories section).
Specication

Double frequency
496131
1.2

Reference (without DIN Plug)


Coil group
Degree of protection
Class of insulation
Electrical connection

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of the Un

VAC/Hz
24/50-60
110/50-60
230/50-60
48/50-60

IP65 according to IEC / EN 60529 standards (with DIN plug).


F 155C
The coil is connected with a 2 P + E plug according to EN 175301-803 type B.
-40C to +50C
The application is limited also by the temperature range of the valve.
3W
3W
60 g
Code
VDC
P0
P2
P9
S4

24 V
48 V
110 V

Code
C2
C4
C5

To Order a Coil choose Coil Ref + Voltage Code, example: 496131 for 24VDC = 496131C2
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

"The housing kit is already included in the coil reference, it is not needed to order it separately."

465

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

1.2

COILS FOR
DIN PLUG CONNECTION

DOUBLE FREQUENCY COIL 22 mm


This coil can be mounted with every Parker solenoid valves
corresponding to the specied Coil Group.
See column "Coil Group" within valve pages.
This coil is designed for valves equipped with a miniature tube assembly
(2000 series valves). This is an encapsulated assembly comprising a
coil, integral magnetic iron path and snap-on plug connection.
The synthetic material encapsulation provides an effective compact
housing, offering full protection against dust, oil, water, etc.
Ease of mounting in confined space - offers shock and corrosion protection
- simplifies conversion of existing equipment to other requirements, etc.
Coil conforms to the IEC/CENELEC safety standards and complies with
European low-voltage directive.
DIN plug connector to be ordered separately (see coil accessories section).
Specication

Double frequency
496482
1.2

Reference (without DIN Plug)


Coil group
Degree of protection
Class of insulation
Electrical connection

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of the Un

VAC/Hz
24/50-60
110/50-60
230/50-60
48/50-60

IP65 according to IEC / EN 60529 standards (with DIN plug).


F 155C
The coil is connected with a 2 P + E plug according to EN 175301-803 type B.
-40C to +50C
The application is limited also by the temperature range of the valve.
3W
3W
75 g
Code
VDC
P0
P2
P9
S4

24 V
48 V
110 V

Code
C2
C4
C5

To Order a Coil choose Coil Ref + Voltage Code, example: 496482 for 24VDC = 496482C2
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

"The housing kit is already included in the coil reference, it is not needed to order it separately."

466

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

1.3

COILS FOR
DIN PLUG CONNECTION

WB COIL SERIES 22 mm
These coils can be mounted with every Parker solenoid valves corresponding
to the specied Coil Group. See column "Coil Group" within valve pages.
These coils can be mounted with the majority of type 2 operators. Coil
manufactured with H class copper wire, moulded in thermoplastic material
polyester with 30% glass ber. IP65 protection rate with DIN 43650A three
pin connector and appropriate gasket.
The synthetic material encapsulation provides an effective compact housing,
offering full protection against dust, oil, water, etc. Coils conforms to the IEC/
CENELEC safety standards and complies with European low-voltage directive.
For UL recognized version: UL file MH19410.
DIN plug connector to be ordered separately (see coil accessories section).
Specication
Ref. (without DIN plug)
Coil Group
Degree of protection
Class of insulation
Electrical connection

Elect.
Power

Ambient temperature
DC
AC

P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of Un for AC
- 5 % to + 10 % for Un DC

Standard
WB4.5 for AC
WB5.0 for DC

UL recognized version
WB4.5 UR
WB5.0 cURus (only 24VDC)
1.3

High Power
WB8.0

IP65 according to IEC / EN 60529 standards (with DIN plug + gasket)


F 155C
F 155C
F 155C
The coil is connected with a 2 P + E plug according to EN 175301-803 type B.
-10C to +50C
-10C to +50C
-10C to +50C
The application is limited also by the temperature range of the valve.
5W
4.5 W
4.5 W
8W
7.5 VA
7.5 VA
11 VA
90 g (without plug)
WB4.5 VAC/Hz

Order Number

WB4.5 UR VAC/Hz

Order Number

WB8.0 VAC/Hz

Order Number

100/50-60
115/50-60
230/50-60
110/50

302609
304260
302612
304316

115/60
208-240/60
24/60

304087
304089
304086

115/50-60
230/50-60
24/50-60

302672
302674
302670

WB5.0 VDC

Order Number

WB5.0 cURus VDC

Order Number

110 VDC
12 VDC

302660
302652

24 VDC

302654

To Order a Coil: Use 6 digits ordering number - Code Example: WB8.0 for 115/50-60 = 302672
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

467

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

20.1

COILS FOR
DIN PLUG CONNECTION

ZB COIL SERIES
These coils can be mounted with every Parker solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
Coil manufactured with H class copper wire, moulded in thermoplastic
material polyester with 30% glass fiber.
IP65 protection rate with EN 175301-803:2006-A. Three pin connector.
This coil conforms to the IEC/CENELEC safety standards and complies
with European low-voltage directive.
For UL recognized version: UL file MH19410.
DIN plug connector to be ordered separately (see coil accessories section).

Specication

Standard
ZB09/ZB12

Reference (without DIN plug)


Coil Group
Degree of protection
Class of insulation
Electrical connection

20.1

Elect.
Power

Ambient temperature
DC
AC

P (cold) 20C
P (cold) 20C
Attraction cold

Weight
Voltages "Un"
-10% to +10% of Un for AC
- 5 % to + 10 % for Un DC.

UL recognized version
ZB09 for AC only

VAC/Hz
ZB09 24/50-60
ZB09 12/50-60
ZB09 230/50-60
ZB09 115/50-60
ZB09 100/50-60
ZB09 240/50-60
ZB09 48/50-60
ZB09 110-120/60
ZB09 380/50-60

IP65 according to IEC / EN 60529 standards (with DIN plug and gasket)
F 155C
The coil is connected with a 2 P + E plug according to EN 175301-803 - A
-10C to +50C
The application is limited also by the temperature range of the valve.
12 W
9W
25 VA
130 g
Order Number
VDC
Order Number
VAC/Hz
304004
304002
304012
304010
304009
304014
304008
304011
304016

ZB12 12DC
ZB12 24DC
ZB12 110DC
ZB12 48VDC

304018
304020
304022
304021

ZB09 24/60
ZB09 110-120/60
ZB09 208-240/60

Order Number
304048
304011
304051

To Order a Coil: Use 6 digits ordering number - Code Example: ZB09 24/50-60 = 304004
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

468

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

20.2

COILS FOR
DIN PLUG CONNECTION

ZB/ZH HIGH POWER - HIGH TEMPERATURE COIL SERIES


These coils can be mounted with every Parker solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
Coil manufactured with H class copper wire, moulded in thermoplastic
material polyester with 30% glass fiber.
IP65 protection rate with EN 175301-803:2006-A. Three pin connector.
This coil conforms to the IEC/CENELEC safety standards and complies
with European low-voltage directive.
DIN plug connector to be ordered separately (see coil accessories section).

Specication

High power

Ref. (without DIN plug)


Ref. (with DIN plug)
Coil Group
Degree of protection
Class of insulation
Electrical connection

ZB14/ZB16

Elect.
Power

AC

ZH14/ZH16
20.2

IP65 according to IEC / EN 60529 standards (with DIN plug and gasket)
F 155C
The coil is connected with a 2 P + E plug according to EN 175301-803 - A
ZB14/ZB16 -10C to +50C
ZH14/ZH16 -10C to +80C
The application is limited also by the temperature range of the valve.

Ambient temperature
DC

High temperature + high power

P (cold) 20C
P (cold) 20C
Attraction cold

Weight
Voltages "Un"
-10% to +10% of Un for AC
- 5 % to + 10 % for Un DC

VAC/Hz

Order
Number

VDC

ZB14 12/50-60
ZB14 24/50-60
ZB14 100/50-60
ZB14 115/50-60
ZB14 230/50-60
ZB14 240/50-60
ZB14 380/50-60
ZB14 48/50-60

304052
304054
304084
304060
304062
304064
304066
304058

ZB16 12DC
ZB16 24DC
ZB16 110DC

16 W
14 W
33 VA
130 g (without plug)
Order
VAC/Hz
Number

Order
Number

VDC

Order
Number

304068
304070
304072

304100
304102
304104

ZH16 24DC
ZH16 12DC

304112
304110

ZH14 24/50-60
ZH14 115/50-60
ZH14 230/50-60

To Order a Coil: Use 6 digits ordering number - Code Example: ZH16 for 24VDC = 304112
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

469

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

21.0

COILS FOR
DIN PLUG CONNECTION

JB COIL SERIES
These coils can be mounted with every Parker solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
Coil manufactured with H class copper wire, moulded in thermoplastic
material polyester with 30% glass fiber.
IP65 protection rate with EN 175301-803:2006-A. Three pin connector.
This coil conforms to the IEC/CENELEC safety standards and complies
with European low-voltage directive.
DIN plug connector to be ordered separately (see coil accessories section).

Specication

Standard
JB14/JB16
21.0

Ref. (without DIN plug)


Coil Group
Degree of protection
Class of insulation
Electrical connection

Elect.
Power

Ambient temperature
DC
AC

P (cold) 20C
P (cold) 20C
Attraction cold

Weight
Voltages "Un"
-10% to +10% of Un for AC
- 5 % to + 10 % for Un DC.

VAC/Hz
JB14 24/50-60
JB14 115/50-60
JB14 230/50-60
JB14 240/50-60

IP65 according to IEC / EN 60529 standards (with DIN plug and gasket)
F 155C
The coil is connected with a 2 P + E plug according to EN 175301-803 - A
-10C to +50C
The application is limited also by the temperature range of the valve.
16 W
14 W
55 VA
130 g (without plug)
Order Number
VDC
Order Number
304900
304910
304915
304920

JB16 12DC
JB16 24DC
JB16 196DC

304945
304950
304958

To Order a Coil: Use 6 digits ordering number - Code Example: JB16 for 12 VDC = 304945
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

470

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

22.0

COILS FOR
DIN PLUG CONNECTION

KT/KH COIL SERIES


These coils can be mounted with every Parker solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
Coil manufactured with H class copper wire, moulded in thermoplastic
material polyester with 30% glass fiber.
IP65 protection rate with EN 175301-803:2006-A. Three pin connector.
This coil conforms to the IEC/CENELEC safety standards and complies
with European low-voltage directive.
DIN plug connector to be ordered separately (see coil accessories section).

Specication

Standard
KT09/KT10

Ref. (without DIN plug)


Coil Group
Degree of protection
Class of insulation
Electrical connection

22.0

Elect.
Power

Ambient temperature
DC
AC

P (cold) 20C
P (cold) 20C
Attraction cold

Weight
Voltages "Un"
-10% to +10% of Un for AC
- 5 % to + 10 % for Un DC

High Temperature
KH09

VAC/Hz
KT09 24/50
KT09 115/50
KT09 208-230/60
KT09-230/50
KT09 240/50

IP65 according to IEC / EN 60529 standards (with DIN plug and gasket)
F 155C
180 (H)
The coil is connected with a 2 P + E plug according to EN 175301-803 - A
-10C to +50C
-10C to +80C
The application is limited also by the temperature range of the valve.
10 W
9W
9W
20 VA
20 VA
150 g (without plug)
Order
VDC
Order
VAC/Hz
Number
Number
304621
304631
304656
304639
304641

KT10 12DC
KT10 24DC

304666
304971

KH09 24/50
KH09 230/50

Order
Number
304746
304748

To Order a Coil: Use 6 digits ordering number - Code Example: KT10 for 12VDC = 304666
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

471

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

23.0

COILS FOR
DIN PLUG CONNECTION

XT09 COIL SERIES


This coil can be mounted with every Parker solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
Coil manufactured with H class copper wire, moulded in thermoplastic
material polyester with 30% glass fiber. IP54 protection rate with
special 2P+E connection. Special plug with integrated powercord
available separately.
This coil conforms to the IEC/CENELEC safety standards and complies
with European low-voltage directive.
DIN plug connector to be ordered separately (see coil accessories section).
Specication
Ref. (without DIN plug)
Coil Group
Degree of protection
Class of insulation
Electrical connection

Elect.
Power

Ambient temperature
DC
AC

P (cold) 20C
P (cold) 20C
Attraction cold

Weight
Voltages "Un"
-10% to +10% of Un for AC

For Heating Applications


XT09
23.0
IP54 according to IEC / EN 60529 standards (with special plug supplied separately)
F 155C
Special 2 P + E plug connection
-10C to +50C
The application is limited also by the temperature range of the valve.
9W
22 VA
150 g (without plug)
VAC/Hz
Order Number
XT09 230/50
304776

To Order a Coil: Use 6 digits ordering number - Code Example: XT09 230/50 = 304776
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

472

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

24.0

COILS FOR
DIN PLUG CONNECTION

D4 SERIES - UL COILS 32 mm
This coil is UL-approved as a recognized component for the insulation
Class 155, conforms to the IEC/CENELEC safety standards and complies
with European low-voltage directive.
DIN plug connector to be ordered separately (see coil accessories section).

Specication

UL Recognized
D4 Series
24.0

Reference (without DIN plug)


Coil group
Degree of protection
Class of insulation
Electrical Connection

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of Un for AC

VAC/Hz

IP65 according to IEC / EN 60529 standards (with DIN plug)


F 155C
The coil is connected with a 2 P + E plug according to EN 175301-803 type A
-40C to +50C
The application is limited also by the temperature range of the valve.
16 W
13 W
40 VA
130 g
Code
VDC

24/60
110/50 - 120/60
220/50 - 240/60

24

D4E
D4F
D4G

Code
D4B

To Order a Coil: Use 6 digits ordering number - Code Example: D4 for 24VAC/60Hz = D4E
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

43,4

37,3

32

19,5

473

23,9

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

24.0

COILS FOR
DIN PLUG CONNECTION

D5 COIL SERIES 32 mm
Encapsulated in synthetic material, Connector for 2P+E according
with DIN EN 175301-803, Form A, IP65 degree of protection to be
considered with connector plug only.
This coil conforms to the IEC/CENELEC safety standards and complies
with European low-voltage directive.
DIN plug connector to be ordered separately (see coil accessories section).

Specication

Mono Frequency VDE Coil


D5 Series
24.0

Reference (without DIN plug)


Coil group
Degree of protection
Class of insulation
Electrical connection

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
P (cold) 20C
Attraction cold

Weight
Voltages "Un"
-10% to +10% of Un for AC

VAC/Hz
24/50
110/50
220-230/50
24/60
230/60
115/60

IP65 according to IEC / EN 60529 standards (with DIN plug)


F 155C
The coil is connected with a 2 P + E plug according to EN 175301-803 type A.
-40C to +50C
The application is limited also by the temperature range of the valve.
9W
8W
40 VA
130 g
Code
VDC
24

D5H
D5XA5
D5L
D5E
D5XJ3
D5XK8

Code
D5B

To Order a Coil: Use 6 digits ordering number - Code Example: D5 for 24 VAC/60 Hz = DSE
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.
43,4

37,3

32

19,5

474

23,9

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

24.0

COILS FOR
DIN PLUG CONNECTION

XS03 COIL SERIES 32 mm


Encapsulated in synthetic material, Connector for 2P+E according
with DIN EN 175301-803, Form A, IP65 degree of protection to be
considered with connector plug only.
This coil conforms to the IEC/CENELEC safety standards and complies
with European low-voltage directive.
DIN plug connector to be ordered separately (see coil accessories section).

Specication

Bi- Frequency VDE Coil


XS03 Series
24.0

Reference (without DIN plug)


Coil group
Degree of protection
Class of insulation
Electrical Connection

IP65 according to IEC / EN 60529 standards (with DIN plug)


F 155C
The coil is connected with a 2 P + E plug according to EN 175301-803 type A
-40C to +50C
The application is limited also by the temperature range of the valve.
9W
32 VA
130 g
VAC/Hz
Code

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of Un for AC

24/50 - 24/60
110-115/50 - 120/60
220-240/50 - 240/60

XS09XM
XS03XS5
XS03XS6

To Order a Coil: Use 6 digits ordering number - Code Example: XS03 for 24/50-24/60 = XS09XM
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

43,4

37,3

32

19,5

475

23,9

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

10.1

COILS FOR
DIN PLUG CONNECTION

COIL FOR OIL AND GAS 37 mm


This coil can be mounted with every Parker solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
This is an encapsulated assembly comprising a coil, integral
magnetic iron path and snap-on plug connection.
The synthetic material encapsulation provides an effective compact
housing, offering full protection against dust, oil, water, etc.
Ease of mounting in confined space - offers shock and corrosion protection
- simplifies conversion of existing equipment to other requirements, etc.
Coils conform to the IEC/CENELEC safety standards and complies with
European low-voltage directive.
DIN plug connector to be ordered separately (see coil accessories section).
Specication

Coil for Oil and Gas 8 W


496895
10.1

Reference (with DIN plug)


Coil group
Degree of protection
Class of insulation
Electrical connection

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of the Un

VAC/Hz
230/50-60
110/50-60
24/50-60
48/50-60

IP65
H 180C
With DIN plug 492459 (AC) or 486586 (DC)
-40C to +50C
The application is limited also by the temperature r ange of the valve.
8W
8W
273 g
Code
VDC
P9
P2
P0
S4

24
48
110

Code
C2
C4
C5

To Order a Coil choose Coil Ref + Voltage Code, example: 496895 for 24VDC = 496895C2
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

476

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

20.1

COILS WITH
FLYING LEADS

YB COIL SERIES IP67


These coils can be mounted with every Parker solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
Coil manufactured with H class copper wire, moulded in thermoplastic
material polyester with 30% glass fiber.
IP67 protection rate. Electrical connection: 2 x 1000 mm cables.
This coil conforms to the IEC/CENELEC safety standards and complies
with European low-voltage directive.
For UL recognized version: UL file MH19410.

Specication

Standard
YB09/YB12

Reference
Coil Group
Degree of protection
Class of insulation
Electrical connection

20.1

Elect.
Power

Ambient temperature
DC
AC

P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of Un for AC
- 5 % to + 10 % for Un DC.

UL recognized version
YB09

VAC/Hz
YB09 115/50-60
YB09 230/50-60
YB09 24/50-60
YB09 240/50-60

IP67 according to IEC / EN 60529 standards


F 155C
The coil is connected with a 2 x 1000 mm ying leads integrated.
-10C to +50C
The application is limited also by the temperature range of the valve.
12 W
9W
9W
24 VA
24 VA
150 g
Order Number
VDC
Order Number
VAC/Hz
Order Number
304396
304398
304390
304400

YB12 12DC
YB12 24DC

304412
304416

YB09 24/60
YB09 110-120/60
YB09 208-240/60

304481
304488
304483

To Order a Coil: Use 6 digits ordering number - Code Example: YB09 for 24 VAC/60 Hz = 304481
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

477

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

24.0

COILS WITH
FLYING LEADS

LA COIL SERIES 32 mm IP67


Encapsulated in synthetic material. Degree of protection IP67 as per
IEC/EN60529.
Connection: 2 x 500 mm cables.
This coil conforms to the IEC/CENELEC safety standards and complies
with European low-voltage directive.

Specication

Coil with two 500 mm ying leads


LA Series
24.0

Reference
Coil group
Degree of protection
Class of insulation

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of Un for AC

VAC/Hz
24/50 - 24/60
110-115/50 - 120/60
220-240/50 - 240/60

IP67 according to IEC / EN 60529 standards


F 155C
-10C to +50C
The application is limited also by the temperature range of the valve.
9W
9W
32 VA
180 g
Code
VDC
24

LAM
LAXS5
LAXS6

Code
LAB

To Order a Coil: Use 6 digits ordering number - Code Example: LA Series for 24 VDC = LAB
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

51,3

5.5

35,8

32

5
500 cable

19,3

478

32

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

24.0

COILS WITH
FLYING LEADS

LB-LC COIL SERIES 32 mm UL IP67


Encapsulated in synthetic material. Degree of protection IP67 as per
IEC/EN60529.
Connection: 2 x 500mm cables.
This coil is UL-approved as a recognized component for the insulation
Class 155, conforms to the IEC/CENELEC safety standards and complies
with European low-voltage directive.

Specication

UL Coil with two 500 mm ying leads


LB-LC Series
24.0

Reference
Coil group
Degree of protection
Class of insulation

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"

VAC/Hz

-10% to +10% of Un for AC

24/60
110/50 - 120/60
208-240/60
220/50 240/60

IP67 according to IEC / EN 60529 standards


F 155C
-10C to +50C
The application is limited also by the temperature range of the valve.
16 W
13-14 W
40 VA
180 g
Code
VDC
LBE
LBF
LBXU3
LBG

24

Code
LCB

To Order a Coil: Use 6 digits ordering number - Code Example: LB-LC for 24 VDC = LCB
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

51,3

5.5

35,8

32

5
500 cable

19,3

479

32

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

2.0/2.1

COILS WITH
FLYING LEADS

COIL 32 mm IP67
This coil can be mounted with every Parker solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
This is an encapsulated assembly comprising a coil, integral
magnetic iron path and snap-on plug connection.
The synthetic material encapsulation provides an effective compact
housing, offering full protection against dust, oil, water, etc.
Ease of mounting in confined space - offers shock and corrosion
protection - simplifies conversion of existing equipment to other
requirements, etc.
Coils conform to the IEC/CENELEC safety standards and complies with
European low-voltage directive.
Specication

Coil with two 500 mm ying leads


496081
2.0 / 2.1

Reference
Coil Group
Degree of protection
Class of insulation

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of Un for AC

VAC/Hz

IP67 according to IEC / EN 60529 standards


F 155C
- 40 C to +50C
The application is limited also by the temperature range of the valve.
9W
9W
32 VA
180 g
Order Number
VDC

24/50 - 24/60
110-115/50 - 120/60
220-240/50 - 240/60

24
12

439816
439820
439822

Order Number
439818
439814

To Order a Coil: Use 6 digits ordering number - Code Example: 496081 for 24VDC = 439818
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

38

For Parker Lucifer valves please order housing Ref: 2995

500 5 cable

52

32

480

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

2.0/2.2

COILS WITH
FLYING LEADS

COIL 32 mm IP67 UL
This coil can be mounted with every Parker solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
This is an encapsulated assembly comprising a coil, integral
magnetic iron path and snap-on plug connection.
The synthetic material encapsulation provides an effective compact
housing, offering full protection against dust, oil, water, etc.
Ease of mounting in confined space - offers shock and corrosion
protection - simplifies conversion of existing equipment to other
requirements, etc.
Coils conform to the IEC/CENELEC safety standards and complies with
European low-voltage directive.
Specication

UL Coil with two 500 mm ying leads


496082
2.0 / 2.2

Reference
Coil Group
Degree of protection
Class of insulation

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"

VAC/Hz

IP67 according to IEC / EN 60529 standards


F 155C
-40C to +120C
The application is limited also by the temperature range of the valve.
16 W
13-14 W
40 VA
180 g
Order Number
VDC

24/60
110/50 - 120/60
208-240/60
220/50 - 240/60

-10% to +10% of Un for AC

439826
439828
439824
439834

24
12

Order Number
439832
439830

To Order a Coil: Use 6 digits ordering number - Code Example: 496082 for 24VDC= 439832
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

38

For Parker Lucifer valves please order housing Ref: 2995

500 5 cable

52

32

481

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

2.0/2.1

COILS WITH
SCREW TERMINALS

STANDARD COILS 40 mm
These coils can be mounted with every Parker Solenoid Valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
They can be mounted with all metal housings.
The coil winding is completely encapsulated in synthetic material.
Easy mounting in confined spaces. Electrical connection with screw
terminals for wire up to 1.5 mm2.
Coils conform to the IEC/CENELEC safety standards and complies with
European low-voltage directive.
Specication

Standard
481000

Reference
Coil Group
Class of insulation

2.0 / 2.1

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of the Un
(-15 % to +5 %
for double-frequency coil
with voltage code
S6 if 240 V/50/Hz is used).

Double Frequency
483520

VAC/Hz
24/50
48/50
110/50-115/50
220/50-230/50

F 155C
-40C to +50C
The application is limited also by the temperature range of the valve..
8W
9W
8W
9W
32 VA (9 W)
36 VA (10 W)
130 g
130 g
Code
VDC
Code
VAC/Hz
A2
A4
0A
3D

24
48
110

C2
C4
C5

24/50-60
48/50-60
110-115/50-120/60
220-240/50-240/60

Code
P0
S4
S5
S6

To Order a Coil choose Coil Ref + Voltage Code, example: 481000 for 24VDC = 481000C2
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

These coils must be used with suitable housings, see examples below:

Ref. 4270 - Protection IP 44

482

Ref. 4538 - Protection IP 67


Parker Hannin Corporation
Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

2.0/2.2

COILS WITH
SCREW TERMINALS

HIGH POWER COILS 40 mm


This coil can be mounted with every Parker Solenoid Valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
They can be mounted with all metal housings.
The coil winding is completely encapsulated in synthetic material.
Easy mounting in confined spaces. Electrical connection with screw
terminals for wire up to 1.5 mm2.
Coils conform to the IEC/CENELEC safety standards and complies with
European low-voltage directive.
Specication
Reference
Coil Group
Class of insulation

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of the Un

High Power
481044
2.0 / 2.2
F 155C
-40C to +50C
The application is limited also by the temperature range of the valve.
14 W
56 VA (20 W)
130 g
VAC/Hz
Code
24/50
110/50
220/50
230/50

A2
A5
A7
F4

To Order a Coil choose Coil Ref + Voltage Code, example: 481044 for 24VAC/50Hz = 481044A2
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

These coils must be used with suitable housings, see examples below:

Ref. 4270 - Protection IP 44

483

Ref. 8520 - Protection IP 67


Parker Hannin Corporation
Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

2.0/2.1
2.2

COILS WITH
SCREW TERMINALS

HIGH TEMPERATURE COILS 40 mm


These coils can be mounted with every Parker Solenoid Valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
They can be mounted with all metal housings.
The coil winding is completely encapsulated in synthetic material.
Easy mounting in confined spaces. Electrical connection with screw
terminals for wire up to 1.5 mm2.
Coils conform to the IEC/CENELEC safety standards and complies with
European low-voltage directive.
Specication

High Temperature
485100
2.0 / 2.1

Reference
Coil Group
Class of insulation

H 180C
-40C to +50C
The application is limited also by the temperature range of the valve.
8W
14 W
9W
21 W
8W
14 W
32 VA (9 W)
56 VA (20 W)
140 g
Code
VAC/Hz
Code
VDC

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of the Un

High Temperature & High Power


486265
2.0 / 2.2

VAC/Hz
24/50
110/50-115/50
220/50-230/50

A2
0A
3D

24/50
110/50
220/50
230/50

A2
A5
A7
F4

12
24
48

Code
C1
C2
C4

To Order a Coil choose Coil Ref + Voltage Code, example: 485100 for 24VAC/50Hz = 485100A2
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

These coils must be used with suitable housings, see examples below:

Ref. 4270 - Protection IP 44

484

Ref. 8520 - Protection IP 67


Parker Hannin Corporation
Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

14.1

COILS WITH
SCREW TERMINALS

HIGH TEMPERATURE & HIGH POWER COILS 40 mm OIL BURNER


These coils can be mounted with every Parker Solenoid Valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
They can be mounted with all metal housings.
The coil winding is completely encapsulated in synthetic material.
Easy mounting in confined spaces. Electrical connection with screw
terminals for wire up to 1.5 mm2.
Coils conform to the IEC/CENELEC safety standards and complies with
European low-voltage directive.
This coil range is used only in safety application according to DIN/EN/
ISO 23551-1:2009-10 (Oil burners)
Specication

High Temperature & High power


483824

Reference
Coil Group
Class of insulation

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of the Un

483541
14.1

VAC/Hz
24/50
110/50-115/50
220/50-230/50

H 180C
-40C to +50C
The application is limited also by the temperature range of the valve.
19 W
20 W
19 W
20 W
19 W
20 W
56 VA (20 W)
56 VA (20 W)
130 g
Code
VAC/Hz
Code
VDC
A2
0A
3D

24/50
110/50
230/50

A2
A5
F4

24
48

Code
C2
C4

To Order a Coil choose Coil Ref + Voltage Code, example: 483541 for 24VDC = 483541C2
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

These coils must be used with suitable housings, Ref: 8760.24 and Ref: 8520.23

Ref. 8760.24

485

Ref. 8520.23
Parker Hannin Corporation
Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

2.0/2.1

COILS WITH
SCREW TERMINALS

COIL DOUBLE FREQUENCY 40 mm H CLASS


This coil can be mounted with every Parker Solenoid Valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
They can be mounted with all metal housings.
The coil winding is completely encapsulated in synthetic material.
Easy mounting in confined spaces. Electrical connection with screw
terminals for wire up to 1.5 mm2.
Coils conform to the IEC/CENELEC safety standards and complies with
European low-voltage directive.
Specication
Reference
Coil Group
Class of insulation

Elect. Power

Ambient temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of the Un

Double Frequency 100 V - 200 V


488553
2.0/2.1
H 180C
-40C to +50C
The application is limited also by the temperature range of the valve.
9W
130 g
VAC/Hz
Code
P1
P6

110/50-60
200/50-60

To Order a Coil choose Coil Ref + Voltage Code, example: 488553 for 110/50-60 = 488553P1
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.

These coils must be used with suitable housings, see examples below:

Ref. 4270 - Protection IP 44

486

Ref. 2985 - Protection IP 54


Parker Hannin Corporation
Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

4.0

COILS WITH
SCREW TERMINALS

BISTABLE COILS 40 mm FOR IMPULSE APPLICATIONS


These coils can be mounted with every Parker solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
These coils are specially designed for Lucifer bistable (or impulse
or magnetic latch) solenoid valves for Heating Applications.
They can be mounted only with the Lucifer metallic housing 4269.
The coil winding is completely encapsulated in synthetic material.
Easy mounting in confined spaces. Electrical connection with screw
terminals for wire up to 1.5 mm2.
Coils conform to the IEC/CENELEC safety standards and complies with
European low-voltage directive.
Specication

Bistable (Impulse)
484990

Reference
Coil Group
Class of insulation
Ambient temperature

Electr. Power consuption

Length of impulses

DC

AC

Attraction (hot)
Attraction (cold)
Release (hot)
Release (cold)
Attraction (hot)
Attraction (cold)
Release (hot)
Release (cold)

Weight
Voltages "Un"
-10% to +10% of the Un

485400
4.0

VAC/Hz

F 155C
-40C to +50C
The application is limited also by the temperature range of the valve.
Switch on (terminals A-B): minimum 50 ms
Switch off (terminals A-C): minimum 35 ms
13 W
19 W
8W
10 W
11 W
17 W
4W
7W
150 g
Code
VDC

24/50-24/60
48/50-48/60
110-115/50-115/60
220-230/50-60

P0
S4
1P
3P

Code
C2
C4
C5

24
48
110

To Order a Coil choose Coil Ref + Voltage Code, example: 485400 for 24VDC = 485400C2
More voltage possibilities can be found in the table of voltage codes at the end of the coil section.
These coils must be used with suitable housings, see examples below:
DIAGRAM
Alternating Current

Direct Current

Only an electrical impulse given to terminals A-C reverses the magnetic eld.
This magnetic eld demagnetises the reversible magnet enough to allow the
return spring to bring the plunger back to its initial position and close the valve.

Ref. 4269 - Protection IP 44

487

Ref. 2985 - Protection IP 54


Parker Hannin Corporation
Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COILS
COIL GROUP

13.0

COILS WITH ISO-DIN


CONNECTORS

COILS 12 V - 24 V FOR TRANSPORTATION APPLICATIONS 32 mm


These coils can be mounted with every Parker solenoid valves corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
These coils are specially designed for Lucifer solenoid
valves for Transportation Applications.
They can be mounted with the standard Lucifer housing
2161 or customized housing.
The coil winding is completely encapsulated in epoxy.
Easy mounting and dismounting in confined spaces.
Bayonet twist and lock coupling for tight, vibration resistant
connection.
Coils conform to the IEC/CENELEC safety standards and
complies with European low-voltage directive.
Specication
Reference
Coil Group
Degree of protection
Ambiant temperature

Transportation
496193

495294
13.0

IP69K per DIN 400050 part 9


-40C to +120C
The application is limited also by the temperature range of the valve and duty cycle of the valve.

Insulation Class

F 155C
ISO 15170-A1-2.3-Sn/K2

DIN 72585-A3-2.1
9w
147 g

Elect. Power

Electrical connection
Pn (hot)
DC
P (cold) 20C
Pn (holding)
AC
Attraction cold
Weight
Voltages "Un"
- 30% to + 30% of the Un

VDC

Code

VDC

Code

12
24

C1
C2

12
24

C1
C2

To Order a Coil choose Coil Ref + Voltage Code, example: 496193 for 24VDC = 496193C2
These coils must be used with suitable housings Ref.2161.

488

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS

TABLE OF CONTENT
INTRODUCTION
Index by Coil Reference................................................................................................................................................................................. 446
Index by Coil Group ......................................................................................................................................................................................... 448
Index for Explosion Proof Electrical Parts............................................................................................................................................. 450
List of Coil Groups ............................................................................................................................................................................................ 451

COILS
Coils for DIN plug connection ..................................................................................................................................................................... 454
Coils with flying leads...................................................................................................................................................................................... 477
Coils with screw terminal............................................................................................................................................................................... 482
Coils with ISO-DIN connector..................................................................................................................................................................... 488

EXPLOSION PROOF ELECTRICAL PARTS


Level of protection "nc AC

.......................................................................................................................................................................... 490

Level of protection "db" ................................................................................................................................................................................. 498


Level of protection "mb"................................................................................................................................................................................ 499
Level of protection "db mb"......................................................................................................................................................................... 504
Level of protection "eb" ................................................................................................................................................................................. 509
Level of protection "ia" ................................................................................................................................................................................... 513

HOUSINGS ....................................................................................................................................................................................................... 522

COIL ACCESSORIES .............................................................................................................................................................................. 526

EXPLOSIVE ENVIRONMENTS ........................................................................................................................................................ 528

COIL APPENDICES
Guidance chart for IS-Barriers.................................................................................................................................................................... 538
Table of voltage codes for coils and electrical parts ....................................................................................................................... 540
489

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

ELECTRICAL PARTS
"nc AC"

ELECTRICAL PART LOW POWER 22 mm


This coil can be mounted with every Parker ATEX solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
Application:
Control of solenoid valves in dangerous areas where explosion-proof
protection Ex nc AC IIC T5 is required.
Benefits:
The synthetic material encapsulation of the coil provides an effective
compact housing, offering full protection against dust, oil, water, etc.
Small size for ease of mounting in confined spaces.
Reference

495865
LCIE 05 ATEX 6003 X
1.1

Certicate
Coil Group
Type of protection

Gas
Dust

II 3 G - Ex nc AC IIC T5
II 3 D - Ex tc IIIC - T 95C
IP65 (with plug) according to IEC/EN 60529
-40C to +50C
The application is limited also by the temperature range of the valve.

Degree of protection
Ambiant temperature
Insulation Class
Electrical connection
Elect. Power

ZONE 2/22

1.1

DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of the Un

F 155C
These coils with connection 2P + G - when mounted together with the supplied Pg 9 plug
(delivered with the coil),
2.5 W
3W
2W
5.7 VA (2.5 W)
120 g
VAC/Hz
Code
VDC
Code
24/50
48/50
110/50-115/50
220/50-230/50

A2
A4
0A
3D

24
48
110

C2
C4
C5

To Order a Coil choose Coil Ref + Voltage Code, example: 495865 for 24VDC = 495865C2

490

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

1.2

ELECTRICAL PARTS
"nc AC"
ZONE 2/22

ELECTRICAL PART DOUBLE FREQUENCY 22 mm


This coil can be mounted with every Parker ATEX solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
Application:
Control of solenoid valves in dangerous areas where explosion-proof
protection Ex nc AC IIC T5 is required.
Benefits:
The synthetic material encapsulation of the coil provides an effective
compact housing, offering full protection against dust, oil, water, etc.
Small size for ease of mounting in confined spaces.
Specication

Double Frequency
496637
ATEX
1.2

Reference
Certicate
Coil group
Type of protection

Gas
Dust

Degree of protection
Ambiant temperature
Elect. Power

Insulation Class
Pn (hot)
DC
P (cold) 20C
Pn (holding)
AC
Attraction cold
Weight
Voltages "Un"
-10% to +10% of the Un

VAC/Hz
24/50-60
110/50-60
230/50-60
48/50-60

II 3 D - Ex tc IIIC - T 95C
IP65 (with plug) according to IEC/EN 60529
-40C to +50C
The application is limited also by the temperature range of the valve.
F 155C
3W
3W
5.7 VA (2.5 W)
75 g
Code
VDC
P0
P2
P9
S4

24 V
48 V
110 V

Code
C2
C4
C5

To Order a Coil choose Coil Ref + Voltage Code, example: 496637 for 24VDC = 496637C2

491

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

ELECTRICAL PARTS
"nc AC"

ELECTRICAL PART 32 mm
These coils can be mounted with every Parker ATEX solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where
explosion-proof protection Ex nc AC IIC T3 to T6 is required.
Ease of mounting in confined space - offers shock and corrosion
protection - simplifies conversion of existing equipment to other
requirements, etc. Coils conforms to the IEC/CENELEC safety standards
and complies with European low-voltage directive.
Small size for ease of mounting in confined spaces.
Reference

495870

496110
LCIE 05 ATEX 6003 X
2.0 / 2.1

Certicate
Coil Group
Type of protection

Gas
Dust

Degree of protection
Insulation Class
Duty cycle
Ambiant temperature
Elect. Power

ZONE 2/22

2.0/2.1

DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of the Un

II 3 G - Ex nc AC IIC T3 / T4
II 3 G - Ex nc AC IIC T3 / T4
II 3 D - Ex tc IIIC - T195C / T130C
II 3 D - Ex tc IIIC - T195C / T130C
IP65 (with plug) according to IEC/EN 60529
F (155C)
100%
-40C to +50C
The application is limited also by the temperature range of the valve.
9W
12 W
8W
9W
26 VA (9 W)
32 VA (10 W)
150 g
VAC/Hz
Code
VDC
Code
VAC/Hz
Code
24/50
48/50
110/50
220-230/50

A2
A4
A5
3D

24
48
110

C2
C4
C5

24/50-60
48/50-60
110/50-60
220/50-60

P0
S4
S5
S6

To Order a Coil choose Coil Ref + Voltage Code, example: 495870 for 24VDC = 495870C2

492

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

6.0

ELECTRICAL PARTS
"nc AC"
ZONE 2/22

ELECTRICAL PART LOW POWER 32 mm


This coil can be mounted with every Parker ATEX solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where
explosion-proof protection Ex nc AC IIC T3 to T6 is required.
Ease of mounting in confined space - offers shock and corrosion
protection - simplifies conversion of existing equipment to other
requirements, etc. Coils conforms to the IEC/CENELEC safety standards
and complies with European low-voltage directive.
Small size for ease of mounting in confined spaces.
Reference

496125
LCIE 05 ATEX 6003 X
6.0

Certicate
Coil group
Type of protection

Gas
Dust

Degree of protection
Insulation Class
Duty cycle

Elect. Power

Ambiant temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of the Un

II 3 G - Ex nc AC IIC T5 / T6
II 3 D - Ex tc IIIC - T80C /T95C
IP65 (with plug) according to IEC/EN 60529
F (155C)
100%
-40C to +50C
The application is limited also by the temperature range of the valve.
1.6 W
2.1 W
150 g
VDC
Code
24
48
110

C2
C4
C5

To Order a Coil choose Coil Ref + Voltage Code, example: 496125 for 24VDC = 496125C2

493

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

ELECTRICAL PARTS
"nc AC"

ELECTRICAL PART 32 mm
This coil can be mounted with every Parker ATEX solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where
explosion-proof protection Ex nc AC IIC T3 to T6 is required.
Ease of mounting in confined space - offers shock and corrosion
protection - simplifies conversion of existing equipment to other
requirements, etc. Coils conforms to the IEC/CENELEC safety standards
and complies with European low-voltage directive.
Small size for ease of mounting in confined spaces.
Specication

32 mm Coil "nc AC"


495875
LCIE 05 ATEX 6003 X
2.0 / 2.1

Reference
Certicate
Coil Group
Type of protection

Gas
Dust

Degree of protection
Insulation Class
Duty cycle
Ambiant temperature
Elect. Power

ZONE 2/22

2.0/2.1

DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of the Un

VAC/Hz
220-230/50

II 3 G - Ex nc AC IIC T3 / T4
II 3 D - Ex tc IIIC - T195C / T130C
IP65 (with plug) according to IEC/EN 60529
F 155C
100%
-40C to +50C
The application is limited also by the temperature range of the valve.
7W
6W
180 g
Code
VDC
3D
24

Code
C2

To Order a Coil choose Coil Ref + Voltage Code, example: 495875 for 24VDC = 495875C2

494

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

NON ENCAPSULATED
ELECTRICAL PARTS
"nc AC"

2.0/2.2

ZONE 2/22

ELECTRICAL PART 32 mm
This coil can be mounted with every Parker ATEX solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where
explosion-proof protection Ex nc AC IIC T3 to T6 is required.
Ease of mounting in confined space - offers shock and corrosion
protection - simplifies conversion of existing equipment to other
requirements, etc. Coils conforms to the IEC/CENELEC safety standards
and complies with European low-voltage directive.
Small size for ease of mounting in confined spaces.
Specication

32 mm Coil "nc AC"


495880
LCIE 05 ATEX 6003X
2.0 / 2.2

Reference
Certicate
Coil Group
Type of protection

Gas
Dust

Degree of protection
Insulation Class
Duty cycle

Elect. Power

Ambiant temperature
DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of the Un

VAC/Hz
24/50
110/50
230/50

II 3 G - Ex nc AC IIC T3 65C
II 3D - Ex tc IIIC - T195C
IP65 (with plug) according to IEC/EN 60529
H 180C
100%
-40C to +50C
The application is limited also by the temperature range of the valve.
14 W
14 W
180 g
Code
VDC
A2
A5
F4

24

Code
C2

To Order a Coil choose Coil Ref + Voltage Code, example: 495880 for 24VDC = 495880C2

495

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

495915 - ELECTRICAL PARTS 50 mm


This coil can be mounted with every Parker ATEX solenoid valves
corresponding to the specied Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where
explosion-proof protection - Ex nc AC IIC T3 is required.
Benets: Rotatable housing 360, galvanized steel with internal and
external screw terminals for earth connection.
Small size for ease of mounting in confined space. Simplifies conversion
of existing equipment to hazardous area requirements.

Reference

495915
LCIE 05 ATEX 6010 X
4.0

Certicate
Coil group
Type of protection

Gas
Dust

II 3 G - Ex nc AC IIC T3
II 3 D - Ex tc IIIC - T 195C
-40C to +65C
The application is limited also by the temperature range of the valve.
F 155C

Ambient temperature
Insulation Class
Electrical connection
Consomation Electrique

ZONE 2/22

4.0

INCREASED SAFETY
ELECTRICAL PARTS
"nc AC"

AC

DC

By special cable gland M20 x 1.5 "EX eb" on screw terminals for wires up to 1.5 mm2.
Cable with outside diameter 6.5 mm to 13.5 mm can be simply sealed using the rubber gland
with resilient sealing rings supplied

Attraction (hot)
Attraction (cold) 20C
Release (hot)
Release (cold) 20C
Attraction (hot)
Attraction (cold) 20C
Release (hot)
Release (cold) 20C

Weight
Voltages "Un"
-10% to +10% of the Un

11 W
17 W
4W
7W
-

13 W
19 W
8W
10 W
320 g

VAC/Hz

Code

VDC

Code

110-115/50-60
220-230/50-60
48/50-60
24/50-60

1P
3P
S4
P0

24
48

C2
C4

Duty cycle

Continuous duty solenoid (ED 100%)

To Order a Coil choose Coil Ref + Voltage Code,


example: 495915 for 24VDC = 495915C2
Schema
AC

DC

As soon as an electrical impulse is given to the terminals A-B, the electromagnetical force attracts
the plunger and simultneously magnetizes a reversible permanent magnet ring. This magnet
retains the plunger in place. It stays in position even without current. Only an electrical impulse
given to terminals A-C reserves the magnetic eld. This magnetic eld demagnetises the reversible
magnet enough to allow the return spring to bring the plunger back to its initial position and close the valve.
Switch: Switch on (terminals A-B): Minimum 50 ms (maximum 1 s)
AC: Switch off (terminals A-C): Minimum 35 ms (maximum 1 s)

496

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

INCREASED SAFETY
ELECTRICAL PARTS
"nc AC"

2.0/2.2

ZONE 2/22

3.5.1 ELECTRICAL PARTS 496155


These coils can be mounted with every Parker solenoid valves
corresponding to the specied Coil Group.
See column "Coil Compatibility Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where
explosion-proof protection Ex nAC IIC T3 is required.
Benets: Rotatable housing 360, galvanized steel with internal and
external screw terminals for earth connection.
Small size for ease of mounting in confined space.Simplifies conversion
of existing equipment to hazardous area requirements.

Reference

496155
LCIE 05 ATEX 6010 X
2.0/2.2

Certicate
Coil Group
Type of protection

Gas
Dust

II 3 G D - Ex nc AC IIC T3
II 3 G D - Ex tc IIIC - T 195 C
IP67
-40C to +65C
The application is limited also by the temperature range of the valve.
F 155C

Degree of protection
Ambiant temperature
Insulation Class

Elect. Power

Electrical connection
DC
AC

By special cable gland or M20x1.5 "Ex nc AC" on screw terminals for wires up to 1.5 mm.
Cables with outside diameter 6.5 mm to 13.5 mm can be simply sealed using the rubber gland
with resilient sealing rings supplied.

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of the Un

14 W
21 W
14 W
56 VA (20 W)
320 g
VAC/Hz

Code

VDC

Code

24/50
110/50
230/50

A2
A5
F4

24
48

C2
C4

To Order a Coil choose Coil Ref + Voltage Code, example: 496155 for 24VAC/50Hz = 496155A2

Fuses:
Both electrical parts have to be connected
in series with a safety fuse according to IEC 60127-3.

497

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

FLAME PROOF
ELECTRICAL PARTS
"db"

483270 & 483270.02 - ELECTRICAL PARTS 50 mm


These coils can be mounted with every Parker ATEX solenoid valves
corresponding to the specied Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where
explosion-proof protection Ex db IIC T4 to T6 is required.
Benets: Rotatable 360, housing made of cast iron with internal
connection chamber: Cover made of aluminium alloy fixed with 4 screws.
The electromagnetic control pilot is composed of three main elements:
housing, coil and plunger tube including housing plate.
Small size for ease of mounting in confined space.
483270 (M20 x 1.5)
483270.02 (1/2 NPT)
LCIE 02 ATEX 6008 X
11.0

Reference
Certicate
Coil group
Type of protection

Gas
Dust

Degree of protection
Ambient temperature
Class of insulation
Electrical connection
Elect. Power

ZONE 1/21

11.0

DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of the Un

II 2 G - Ex db IIC T4
II 2 D - Ex tb IIIC - T130C

II 2 G - Ex db IIC T5
II 2 G - Ex db IIC T6
II 2 D - Ex tb IIIC - T 95C
II 2 D - Ex tb IIIC - T 80C
IP66 with appropriate cable gland
-40 to +80C
-40C to +75C
-40C to +60C
The application is limited also by the temperature range of the valve.
F (155 )
The electrical connection is made within the housing connection chamber on an accessible screw terminal. The cable
entry to the connecting chamber is made through 1/2" NPT thread suitable for tting an approved Ex db IIC cable gland.
8W
9W
8W
9W
1100 g (with coil)
VAC/Hz
Code
VDC
Code
24/50-60
110-115/50-60
220-230/50-60

P0
1P
3P

24
48
110

C2
C4
C5

To Order a Coil choose Coil Ref + Voltage Code, example: 483270 for 24VDC = 483270C2

Plunger tube:
The plunger tube is welded to the stainless steel plate and is thus integrated
to the housing which is screwed on the valve body.
This electrical part is supplied only as complete unit mounted on a valve,
as the "Ex db" protection depends on minimum gap between plunger tube,
plate and housing.

498

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

ENCAPSULATED
ELECTRICAL PARTS
"mb"

1.1

ZONE 1/21

ELECTRICAL PART LOW POWER 22 mm


These coils can be mounted with every Parker ATEX solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
Application:
Control of solenoid valves in dangerous areas where explosion-proof
protection Ex mb II T4 or T5 is required.
Benefits:
Coil and magnetic circuit encapsulated in synthetic material - offering
shock and corrosion protection. AC coils with integrated thermal fuse.
Small size for ease of mounting in confined spaces.
Reference

482605

Certicate
Coil Group
Type of protection

Gas
Dust

Degree of protection
Ambiant temperature

Elect. Power

Insulation Class
Electrical connection
Pn (hot)
DC
P (cold) 20C
Pn (holding)
AC
Attraction cold
Weight
Voltages "Un"
-10% to +10% of the Un

482606 or 482606.160*
LCIE 02 ATEX 6014 X - IECEx LCI 07.0026 X
1.1

II 2 G - Ex mb II T4
II 2 G - Ex mb II T4
II 2 G - Ex mb II T5
II 2 D - Ex tb IIIC - T130C
II 2 D - Ex tb IIIC - T130C
II 2 D - Ex tb IIIC - T 95C
IP65 (with plug) according to IEC/EN 60529
-40C to +50C
-40C to +65C
-40C to +40C
The application is limited also by the temperature range of the valve.
F 155C
Cable connection (3 x 0.75 mm) encapsulated with coil, cable material according to application
5W
2.5 W
6.5 W
3W
4W
2W
8.9 VA (5 W)
5.7 VA (2.5 W)
150 g
VAC/Hz
Code
VDC
Code
VAC/Hz
Code
VDC
Code
24/50
110/50-115/50
220/50-230/50

A2
0A
3D

24
110

C2
C5

24/50
48/50
110/50-115/50
220/50-230/50

A2
A4
0A
3D

24
48
110

C2
C4
C5

To Order a Coil choose Coil Ref + Voltage Code, example: 482605 for 24VDC = 482605C2
* 482606.160 - 6 m cable length

Fuses:
Both electrical parts 482605 & 482606 have to be connected in series
with a safety fuse according to CEI 60127-3. Indicating example bellow:
482605:
DC:
AC 50 HZ:
AC 60 Hz:

12 V, 1000 mA - 24 V, 500 mA - 48 V, 200 mA - 110 V, 100 mA


24 V, 500 mA - 48 V, 250 mA - 110/115 V, 100 mA - 220/230 V, 3 mA
24 V, 630 mA - 110/115 V, 125 mA - 220/230 V, 63 mA

482606:
DC:
AC 50 HZ:
AC 60 Hz:

12 V, 400 mA - 24 V, 200 mA - 48 V, 100 mA - 110 V, 50 mA


24 V, 250 mA - 48 V, 125 mA - 110/115 V, 63 mA - 220/230 V, 32 mA
24 V, 315 mA - 110/115 V, 63 mA - 220/230 V, 32 mA

499

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

ENCAPSULATED
ELECTRICAL PARTS
"mb"

ELECTRICAL PART 32 mm
This coil can be mounted with every Parker ATEX solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where
explosion-proof protection Ex mb II T4 is required.
Benefits: Coil and magnetic circuit encapsulated in synthetic material
offering shock and corrosion protection. AC/DC coils with integrated
thermal fuse. DC coils with integrated surge suppression diode.
Small size for ease of mounting in confined spaces.

Reference

492670 or 492670.10* or 492670.160**


LCIE 02 ATEX 6015 X
2.0 / 2.1

Certicate
Coil Group
Type of protection

Gas
Dust

Degree of protection
Ambiant temperature
Class of insulation
Electrical connection
Pn (hot)
DC
P (cold) 20C
Pn (holding)
AC
Attraction cold
Weight
Voltages "Un"
-10% to +10% of the Un
Elect. Power

ZONE 1/21

2.0/2.1

II 2 G - Ex mb II T4
II 2 D - Ex tb IIIC - T130C
IP65 (With DIN Plug connector) acc. to IEC 60529
-40C to +40C
The application is limited also by the temperature range of the valve.
F 155C
Cable connection (3 x 1.5 mm) encapsulated with coil, cable material according to application
9W
12 W
8W
26 VA (9 W)
320 g
VAC/Hz
Code
VDC
Code
48/50
230/50

A4
F4

24
48
110

C2
C4
C5

To Order a Coil choose Coil Ref + Voltage Code, example: 492670 for 24VDC = 492470C2
* 492670.10 for stainless steel application - 3 m cable length
** 492670.160 - 6 m cable length

Special conditions:
The supply connection lines have to be xed and positioned in such a way that they
are protected against mechanical damages.
It is necessary to use a safety fuse with a nominal current
corresponding to the coil current (max. 3 x nominal according
to IEC 60127 and IEC 60269) against short-circuits.
Recommended values:
DC:
12 V, 1250 mA - 24 V, 630 mA - 48 V, 315 mA - 110 V, 125 mA
AC 50 HZ: 24 V, 1000 mA - 48 V, 500 mA - 110 V, 250 mA - 230 V, 100 mA
AC 60 Hz: 240 V, 100 mA

500

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

ENCAPSULATED
ELECTRICAL PARTS
"mb"

2.0/2.1

ZONE 1/21

WITH WATER PROOF METAL HOUSING 50 mm


These coils can be mounted with every Parker ATEX solenoid valves
corresponding to the specied Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where
explosion-proof protection Ex mb II T4 or T5 is required.
Benets: Epoxy-coated steel housing - solenoid coil, rectifier (silicium
diodes), fuse and varistor protection element are completely encapsulated
in the coil housing by means of epoxy resin.
Small size for ease of mounting in confined space. Simplifies conversion
of existing equipment to hazardous area requirements.
492070
492070.160 ( with 6m cable length )
LCIE 02 ATEX 6017 X - IECEx LCI 09.0024 X
2.0 / 2.1

Reference
Certicate
Coil Group
Type of protection

Gas
Dust

Ambient temperature

Elect. Power

Insulation Class
Electrical connection
Pn (hot)
DC
P (cold) 20C
Pn (holding)
AC
Attraction cold
Weight
Voltages "Un"
-10% to +10% of the Un

II 2 G - Ex mb II T4
II 2 G - Ex mb II T5
II 2 D - Ex tb IIIC - T130C
II 2 D - Ex tb IIIC - T95C
-40C to +65C
-40C to +40C
The application is limited also by the temperature range of the valve.
F 155C
Cable connection (3 x 1.5 mm) with cable gland M20 x 1.5, external earth screw connection.
8W
10 W
9W
11 W
500 g
VAC/Hz
Code
VDC
Code
24/50-60
110/50-60
220/50-60
230/50-60
240/50-60

P0
P2
R5
P9
Q1

24
48
110

C2
C4
C5

To Order a Coil choose Coil Ref + Voltage Code, example: 492070 for 24VDC = 492070C2

501

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

ENCAPSULATED
ELECTRICAL PARTS
"mb"

HZ10 COIL DOUBLE FREQUENCY


This coil can be mounted with every Parker ATEX solenoid valves
corresponding to the specied Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where
explosion-proof protection Ex mb II T4 or T5 is required.

Specication

Double Frequency
HZ10
LCIE 02 ATEX 6020 X - IECEx LCI 08.0027 X
2.0 / 2.1

Reference
Certicate
Coil Group
Type of protection

Gas
Dust

II 2 G - Ex mb II T4/T5
II 2 D - Ex tb IIIC T
IP65 (with plug)according to IEC/EN 60529
-40C to + 65C
The application is limited also by the temperature range of the valve.

Degree of protection
Ambient temperature
Insulation Class
Duty cycle
Electrical connection
Pn (hot)
DC
P (cold) 20C
Pn (holding)
AC
Attraction cold
Weight
Voltages "Un"

H 180C
100% continuous
Cable connection (3 x 1.5 mm) with cable gland M20 x 1.5, external earth screw connection.
8W
8W
299 g
VAC/Hz
Code
VDC
Code

Elect. Power

ZONE 1/21

2.0/2.1

-10% to +10% of the Un

24
110

C2
C5

110/50
220/50

A5
A7

To Order a Coil choose Coil Ref + Voltage Code, example: HZ10 for 24VDC = HZ10C2

1.53

3.86

Dimensions in Inches.

3.05

1.62

502

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

ENCAPSULATED
ELECTRICAL PARTS
"mb"

2.0/2.2

ZONE 1/21

HZ11 COIL DOUBLE FREQUENCY


This coil can be mounted with every Parker ATEX solenoid valves
corresponding to the specied Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where explosionproof protection Ex mb II T4 or T5 is required.

Specication

Double Frequency
HZ11
LCIE 02 ATEX 6020 X - IECEx LCI 08.0027 X
2.0 / 2.2

Reference
Certicate
Coil Group
Type of protection

Gas
Dust

II 2 G - Ex mb II T4/T5
II 2 D - Ex tb IIIC T
IP65 (with plug)according to IEC/EN 60529
-40C to + 50C
The application is limited also by the temperature range of the valve..

Degree of protection
Ambient temperature

H 180 C
100% continuous
14 W
14 W
299 g

Elect. Power

Insulation Class
Duty cycle
Pn (hot)
DC
P (cold) 20C
Pn (holding)
AC
Attraction cold
Weight
Voltages "Un"
-10% to +10% of the Un

VAC/Hz

Code

VDC

Code

110/50
220/50

A5
A7

24 V

C2

To Order a Coil: Coil Ref + Voltage Code, example: HZ11 for 24VDC = HZ11C2

1.53

3.86

Dimensions in Inches.

3.05

1.62

503

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUPS

FLAME PROOF ENCAPSULATED


ELECTRICAL PARTS
"db mb"

495900 - LOW POWER ELECTRICAL PARTS 37 mm


This coil can be mounted with every Parker ATEX solenoid valves corresponding to the specied Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas
where explosion-proof protection Ex db mb IIC T4 to T6 is
required.
Benets: Rotatable 360 fibreglass-reinforced plastic
housing (class H). Solenoid coil, rectifier (silicium diodes),
fuses and varistor protection are completely encapsulated
into the coil housing by epoxy resin for shock and corrosion
protection.
The plastic housing is delivered with M20 x 1.5 cable gland
certified for use "db" protection. Small size for ease of
mounting in confined space.
Reference
495900
Certicate
LCIE 03 ATEX 6451 X - IECEx LCI 06.0004 X
Coil Group
6.0
Type of protection

Gas
Dust

Degree of protection
Ambient temperature
Class of insulation
Electrical connection
Pn (hot)
P (cold) 20C
Pn (holding)
AC
Attraction cold
Voltages "Un"
Elect. Power

ZONE 1/21

6.0

DC

-10% to +10% of Un for AC


- 10 % to + 10 % for Un DC.

II 2 G - Ex db mb IIC T4 / T5 / T6
II 2 D Ex tb IIIC - 130C / 95C / 80C

II 2 G - Ex db mb IIC T5 / T6
II 2 D Ex tb IIIC - 95C / 80C

IP67
-40C to +65C / +55C / +40C
-40C to +65C / +55C
The application is limited also by the temperature range of the valve.
H (180 )
Electric connection is done in the connection box on an easily accessible connector terminals. The introduction of the cable
( min 5 mm, max. 11 mm, section max. 2.5 mm) in the connection box passes by the built in M20 x 1.5 cable gland
2W
2.5 W
2.5 W
3W
VAC/Hz
Code
VDC
Code
24/50
48/50
115/50
230/50

A2
A4
E5
F4

24
48
110

C2
C4
C5

To Order a Coil: Coil Ref + Voltage Code, example: 495900 for 24VDC = 495900C2

504

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUPS

FLAME PROOF ENCAPSULATED


ELECTRICAL PARTS
"db mb"

2.0/2.1

ZONE 1/21

495905 - ELECTRICAL PARTS 37 mm


These coils can be mounted with every Parker ATEX solenoid valves
corresponding to the specied Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where
explosion-proof protection Ex db mb IIC T4 is required.
Benets: Rotatable 360 fibreglass-reinforced plastic housing (class H).
Solenoid coil, rectifier (silicium diodes), fuses and varistor protection are
completely encapsulated into the coil housing by epoxy resin for shock
and corrosion protection.
The plastic housing is delivered with M20 x 1.5 cable gland certified for
use "db" protection. Small size for ease of mounting in confined space.
Reference

495905

Certicate
Coil Group
Type of protection

Gas
Dust

Degree of protection
Ambient temperature
Class of insulation
Electrical connection
Elect. Power

Pn (hot)
P (cold) 20C
Pn (holding)
AC
Attraction cold
Voltages "Un"
DC

-10% to +10% of Un for AC


- 10 % to + 10 % for Un DC.

495905.05
LCIE 03 ATEX 6451 X - IECEx LCI 06.0004 X
2.0 / 2.1

II 2 G - Ex db mb IIC T4
II 2 D - Ex tb IIIC - 130C
IP67
-40C to +65C
The application is limited also by the temperature range of the valve.
H (180 )
Electric connection is done in the connection box on an easily accessible connector terminals. The introduction of the cable
( min 5 mm, max. 11 mm, section max. 2.5 mm) in the connection box passes by the built in M20 x 1.5 cable gland.
8W
9W
8W
9W
VAC/Hz
Code
VDC
Code
24/50
48/50
115/50
230/50

A2
A4
E5
F4

24
48
110

C2
C4
C5

To Order a Coil choose Coil Ref + Voltage Code, example: 495905 for 24VDC = 495905C2

495905

*495905.05

505

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

496555 & 496560 - ELECTRICAL PARTS 37 mm


These coils can be mounted with every Parker ATEX solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where
explosion-proof protection Ex db mb IIC T4 to T6 is required.
Benefits: Rotatable 360 fibreglass-reinforced plastic housing (class H).
Solenoid coil, rectifier (silicium diodes), fuses and varistor protection are
completely encapsulated into the coil housing by epoxy resin for shock
and corrosion protection.
The plastic housing is delivered with M20 x 1.5 cable gland certified for
use "db" protection. Small size for ease of mounting in confined space.
Reference

496555

Type of protection

496560
LCIE 07 ATEX 6075 X - IECEx LCI 07.0014X

Certicate
Coil Group
Gas
Dust

10.2

10.1

II 2 G - Ex db mb IIC T4 / T5 / T6
II 2 D - Ex tb IIIC - T130 / 95 / 80C

II 2 G - Ex db mb IIC T4
II 2 D - Ex tb IIIC - T130C

Degree of protection

IP 67

Ambiant temperature

-40C to +65C
The application is limited also by the temperature range of the valve.
H (180 )
Electric connection is done in the connection box on an easily accessible connector terminals. The introduction of the cable
( min 5 mm, max. 11 mm, section max. 2.5 mm) in the connection box passes by the built in M20 x 1.5 cable gland.
6W
8W
7.5 W
10.5 W
6W
8W
7.5 W
10.5 W
VAC/Hz
Code
VDC
Code
VAC/Hz
Code
VDC
Code

Class of insulation
Electrical connection
Pn (hot)
P (cold) 20C
Pn (holding)
AC
Attraction cold
Voltages "Un"
Elect. Power

ZONE 1/21

10.2/10.1

FLAME PROOF ENCAPSULATED


ELECTRICAL PARTS
"db mb"

DC

-10% to +10% of the Un

230/50-60
110/50-60
24/50-60
48/50-60

P9
P2
P0
S4

24
48
110

C2
C4
C5

230/50-60
110/50-60
24/50-60
48/50-60

P9
P2
P0
S4

24
48
110

C2
C4
C5

To Order a Coil choose Coil Ref + Voltage Code, example: 496555 for 24VDC = 496555C2

506

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

10.2/10.1

FLAME PROOF ENCAPSULATED


ELECTRICAL PARTS
"db mb"
ZONE 1/21

496700 & 496800 - ELECTRICAL PARTS 37 mm


These coils can be mounted with every Parker ATEX solenoid valves
corresponding to the specied Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where
explosion-proof protection Ex db mb IIC T4 to T6 is required.
Benets: Rotatable 360 fibreglass-reinforced plastic housing (class H).
Solenoid coil, rectifier (silicium diodes), fuses and varistor protection are
completely encapsulated into the coil housing by epoxy resin for shock
and corrosion protection.
The plastic housing is delivered with 1/2" or M20 x 1.5 threaded hole for wide
range of cable glands. Small size for ease of mounting in confined space.
Reference

496700

Type of protection

496800
LCIE 07 ATEX 6075 X - IECEx LCI 07.0014X

Certicate
Coil Group
Gas
Dust

10.2

10.1

II 2 G - Ex db mb IIC T4 / T5 / T6
II 2 D - Ex tb IIIC - T130 / 95 / 80C

II 2 G - Ex db mb IIC T4
II 2 D - Ex tb IIIC - T130C

IP67

Degree of protection
Ambiant temperature
Class of insulation
Electrical connection
Elect. Power

Pn (hot)
P (cold) 20C
Pn (holding)
AC
Attraction cold
Voltages "Un"
DC

-10% to +10% of the Un

-40C to +35C / +50C / +65C


-40C to +65C
The application is limited also by the temperature range of the valve.
H (180)
Electric connection is done in the connection box on an easily accessible connector terminals. The introduction of the cable
( min 5 mm, max. 11 mm, section max. 2.5 mm) in the connection box passes by the built in M20 x 1.5 cable gland.
6W
8W
7.5 W
10.5 W
6W
8W
7.5 W
10.5 W
VAC/Hz
Code
VDC
Code
VAC/Hz
Code
VDC
Code
230/50-60
110/50-60
24/50-60
48/50-60

P9
P2
P0
S4

24
48
110

C2
C4
C5

230/50-60
110/50-60
24/50-60
48/50-60

P9
P2
P0
S4

24
48
110

C2
C4
C5

To Order a Coil choose Coil Ref + Voltage Code, example: 496700 for 24VDC = 496700C2

507

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

FLAME PROOF ENCAPSULATED


ELECTRICAL PART
"db mb"

493640 OR HZ09 - ELECTRICAL PARTS


This coil can be mounted with every Parker ATEX solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where
explosion-proof protection Ex db mb II 2 G/D T4 to T5 is required.
Benefits: Metal armature encapsulated in synthetic material provides
high shock and corrosion protection.
Small size for ease of mounting in confined space.

Reference

493640 or HZ09
493640.60* or HZ55

Certicate
Coil Group

LCIE 02 ATEX 6009 X


2.0 / 2.1

Type of protection

Gas
Dust

Degree of protection
Ambiant temperature
Class of insulation
Electrical connection
Elect. Power

ZONE 1/21

2.0/2.1

DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
- 15% to +10% of the Un

VAC/Hz
110/50
110-120/50-60
220-240/50-60

II 2 G - Ex db mb T4/T5
II 2 D - Ex tb IIIC - T130C / T95C
IP65
- 40C to +75C / +40C
The application is limited also by the temperature range of the valve.
F (155 )
Special "Ex db" cable gland, galvanized steel, with EPDM sealing.
(EPR) cable, outside diameter 7.3 0.5 mm and 3000 mm long.
8W
9W
8W
32 VA (9 W)
500 g
Code
VDC
A5
P3
Q3

24
48
120

To Order a Coil choose Coil Ref + Voltage Code, example: 493640 for 24VDC = 493640C2

Code
C2
C4
C6

* 493640.60 - 6 m cable length

Fuses
This electrical part is equipped with a standard thermal cut-off fuse on all
models and voltages
This electrical part must be connected in series with a safety fuse according
to IEC 60127-3.
DC: 24V, 400 mA
AC: 110/50-120/60, 200 mA
220/50-240/60, 100 mA
230/50, 95 mA

508

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

INCREASED SAFETY
ELECTRICAL PARTS
"eb"

2.0/2.1

ZONE 1/21

483371 & 494040 - ELECTRICAL PARTS 50 mm


This coil can be mounted with every Parker ATEX solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where
explosion-proof protection Ex eb II T3 orT4 is required.
Benefits: Rotatable housing 360, galvanized steel with internal and
external screw terminals for earth connection.
Small size for ease of mounting in confined space.Simplifies conversion
of existing equipment to hazardous area requirements.

Reference

483371
LCIE 02 ATEX 6011 X

Certicate
Coil Group

2.0 / 2.1

Type of protection

Gas
Dust

Degree of protection
Ambiant temperature
Class of insulation

Elect. Power

Electrical connection
DC
AC

494040
LCIE 02 ATEX 6013 X

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of the Un

II 2 G - Ex eb IIC T4
II 2 D - Ex tb IIIC - T130C

II 2 G - Ex eb IIC T3 / T4
II 2 D - Ex tb IIIC - T195C / T130C

IP67
-40C to +65C
-40C to +90C / to +65C
The application is limited also by the temperature range of the valve.
F 155C
F (180)
By special cable gland or M20 x 1.5 "Ex eb" on screw terminals for wires up to 1.5 mm. Cables with outside diameter
6.5 mm to 13.5 mm can be simply sealed using the ru bber gland with resilient sealing rings supplied.
8W
8W
9W
9W
8W
8W
32 VA (9 W)
32 VA (9 W)
320 g
VAC/Hz
Code
VDC
Code
VAC/Hz
Code
VDC
Code
24/50
48/50
110-115/50
220-230/50

A2
A4
OA
3D

24
48
110

C2
C4
C5

220-230/50

3D

24

C2

To Order a Coil choose Coil Ref + Voltage Code, example: 483371 for 24VDC = 483371C2

Fuses:
Both electrical parts have to be connected in series
with a safety fuse according to IEC 60127-3.
483371:
DC:
24 V, 400 mA - 48V, 250 mA - 110 V, 100 mA
AC 50HZ: 24 V, 630 mA - 48V, 315 mA - 110 V, 160 mA - 220/230 V, 80 mA

494040:
DC:
12 V, 400 mA - 24V, 200 mA - 48 V, 100 mA - 110V, 50 mA
AC 50HZ: 24 V, 250 mA - 48V, 125 mA - 110/115 V, 63 mA - 220/230 V, 32 mA

509

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

INCREASED SAFETY
AND ENCAPSULATED
ELECTRICAL PARTS "eb"

492310 - ELECTRICAL PARTS 50 mm


This coil can be mounted with every Parker ATEX solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where
explosion-proof protection Ex eb mb II T4 to T5 is required.
Benefits: Rotatable 360 fibreglass-reinforced plastic housing. Solenoid
coil, rectifier (silicium diodes), fuses and varistor protection are
completely encapsulated into the coil housing by epoxy resin for shock
and corrosion protection.
Small size for ease of mounting in confined space.
Reference

492310
LCIE 02 ATEX 6023 X - IECEx LCI 06.0011 X
10.1

Certicate
Coil group
Type of protection

Gas
Dust

Degree of protection
Ambiant temperature
Class of insulation
Electrical connection
Pn (hot)
DC
P (cold) 20C
Pn (holding)
AC
Attraction cold
Weight
Voltages "Un"
-10% to +10% of the Un
Elect. Power

ZONE 1/21

10.1

II 2 G - Ex eb mb II T4 / T5
II 2 D - Ex tb IIIC - T130C / T95C
IP66
-40C to +75C / to +40C
The operating temperature of the valve/coil can be limited by that of the valve
F 155C
Connection box with terminals and cable entry via gland M20 x 1.5 - Possibility for additional earth via external screw.
6W
7.5 W
6W
7.5 W
500 g
VAC/Hz
Code
VDC
Code
24/50-60
48/50-60
230/50-60

P0
S4
P9

24
48
110

C2
C4
C5

To Order a Coil choose Coil Ref + Voltage Code, example: 492310 for 24VDC = 492310C2

510

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

492210 - ELECTRICAL PARTS "BOOSTER" 50 mm


These coils can be mounted with every Parker ATEX solenoid valves
corresponding to the specied Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where
explosion-proof protection - Ex eb mb IIC T5/T6 is required.
Benets: Rotatable housing 360, galvanized steel with internal and
external screw terminals for earth connection.
Small size for ease of mounting in confined space. Simplifies conversion
of existing equipment to hazardous area requirements.

Reference

492210
LCIE 02 ATEX 6023 X - IECEx LCI 06.0011 X
9.0

Certicate
Coil group
Type of protection
Degree of protection
Ambient temperature
Insulation Class
Electrical connection
Power consumption DC
Attraction current
Voltage DC
Resistance
Inductance
Capacitance
Response time
Weight

Gas
Dust

II 2 G - Ex eb mb IIC T5 / T6
II 2 D - Ex tb IIIC - T95C / T80C
IP66
-40C to +75C / +40C
The operating temperature of the valve/coil can be limited by that of the valve
F 155C
Connection box with terminals and cable entry via gland M20 x 1.5
Possibility for additional earth via external screw
1 to 1.8 W according to length of cable
I min = 60 mA (I nominal = 75 mA)
U nominal = 24 VDC (C2), Umin = 21.6 VDC
23 + (R = 270 )
0 mH
0 F
2-4s
500 g

To Order a Coil choose Coil Ref + Voltage Code, example: 492210 for 24VDC = 492210C2

Indications:
Booster for Offshore valves

These electrical parts need an external fuse of I = 100 mA

511

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

ZONE 1/21

9.0

INCREASED SAFETY
AND ENCAPSULATED
ELECTRICAL PARTS "eb"

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

INCREASED SAFETY
AND ENCAPSULATED
ELECTRICAL PARTS "eb"

492190 - ELECTRICAL PARTS 50 mm


This coil can be mounted with every Parker ATEX solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where
explosion-proof protection Ex eb mb IIC T3 to T4 is required.
Benefits: Rotatable 360, fiberglass -reinforced plastic housing.
Solenoid coil, rectifier (silicium diodes), fuses and varistor protection are
completely encapsulated into the coil housing by epoxy resin for shock
and corrosion protection.
Small size for ease of mounting in confined space.
Reference

492190
LCIE 02 ATEX 6023 X - IECEx LCI 06.0011 X
2.0 / 2.1

Certicate
Coil Group
Type of protection

Gas
Dust

Degree of protection
Ambient temperature
Insulation Class
Electrical connection
Electrical
consumption

ZONE 1/21

2.0/2.1

DC
AC

Pn (hot)
P (cold) 20C
Pn (holding)
Attraction cold

Weight
Voltages "Un"
-10% to +10% of the Un

VAC/Hz
24/50-60
48/50-60
110/50-60
230/50-60

II 2 G - Ex eb mb IIC T3 / T4
II 2 D - Ex tb IIIC - 195C / 130C
IP66
-40C to +75C / +40C
The operating temperature of the valve/coil can be limited by that of the valve
F 155C
Connection box with terminals and cable entry via gland M20 x 1.5
Possibility for additional earth via external screw
9W
11 W
11 W
13 W
320 g
Code
VDC
P0
S4
P2
P9

24
48
110

Code
C2
C4
C5

To Order a Coil choose Coil Ref + Voltage Code, example: 492190 for 24VDC = 492190C2

512

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

INTRINSICALLY SAFE
ELECTRICAL PARTS
"ia"

7.0

ZONE 0/20

ELECTRICAL PARTS 32 mm "IS"


These coils can be mounted with every Parker ATEX solenoid valves
corresponding to the specied Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where
explosion-proof protection Ex ia or ib IIC T6 is required.
Benets: Fully encapsulated assembly comprising a coil, metal armature,
three diodes circuit and DIN plug connection.
The encapsulation provides an effective compact housing offering full
protection against dust, oil, water, etc.
Small size for ease of mounting in confined space.
Reference (without plug)
(with plug)

LCIE 02 ATEX 6065 X - IECEx LCI 07.0025 X


7.0

Certicate
Coil Group
Type of protection
Degree of protection
Ambiant temperature
Class of insulation
Electrical connection

Power

Maximum supply voltage


DC

483580.01 or DZ12
483960.01 or DZ13

Minimum
Maximum

Gas
Dust

II 1 G - Ex ta IIIC - T6
II 1 D - Ex ta IIIC - T80C
IP65 with plug
- 40C + 55C
The operating temperature of the valve/coil can be limited by that of the valve.
F 155C
The coil is connected with a 2P + E plug according to EN 175301-803 type A
Contact 1 is marked as the positive pole .
28 VDC (N7) - 110 mA
The minimum operating voltage at maximum 60C is 14 VDC.
500 mW
3W
Depending on applied voltage, IS barrier type and resistance of connected cable

Coil resistance at 20C


Impedance
Apparent inductance
Apparent capacitance

340
340
0 mH
0 F

Weight

160 g (with plug)

To Order a Coil choose Coil Ref + Voltage Code, example: 483580 for 28VDC = 483580N7
Important
The intrinsically safe supply circuit should have enough capacity in all
environmental conditions to assure a minimum operating current of 35 mA
through the coil.
The minimal holding current is 20 mA.

For the barrier compatibility see the corresponding table in in appendix


section.

513

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

495910 - MINIWATT - 0.3 W


ELECTRICAL PARTS "IS" "BOOSTER" 37 mm
These coils can be mounted with every Parker ATEX solenoid valves
corresponding to the specied Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where
explosion-proof protection Ex ia IIC T4 to T6 is required.
Benets: Rotatable 360 fibreglass-reinforced plastic housing (class H).
Solenoid coil, rectifier (silicium diodes), fuses and varistor protection are
completely encapsulated into the coil housing by epoxy resin for shock
and corrosion protection.
The plastic housing is delivered with M20 x 1.5 cable gland. Small size for
ease of mounting in confined space.
495910

Reference

Type of protection
Degree of protection
Ambiant temperature
Electrical connection
Maximum supply voltage
Minimum
DC
Maximum
Line check
Coil resistance at 20C
Impedance
Apparent inductance
Apparent capacitance
Response time
Weight

495910.02 (Blue Cable Gland)


LCIE 03 ATEX 6464 X - IECEx LCI 07.0006 X
8.0

Certicate
Coil Group

Power

ZONE 0/20

8.0

INTRINSICALLY SAFE
ELECTRICAL PARTS
"ia"

Gas
Dust

II 1 G - Ex ta IIIC - T6 T5 T4

II 1 G - Ex ia IIB - T6 T5 T4
II 1 D - tD A20 - T80 T95 T130C
IP67
- 40C to +65C / +75C / +80C
The application is limited also by the temperature range of the valve..
Electric connection is done in the connection box on an easily accessible connector terminals. The introduction of the cable
( min 7 mm, max. 11 mm, section max. 2.5 mm) in the connection box passes by the built in M20 x 1.5 cable gland
28 VDC (N7) - 110 mA
28 VDC (N7) - 280 mA
0.3 W (with 13 VDC)
0.3 W (with 13 VDC)
1.2 W (with 24 VDC)
2.58 W (with 24 VDC)
Depending on applied voltage, IS barrier type and resistance of connected cable
4 mA or 5 VDC max
Charge ~ 550 - Holding ~ 500
0 mH
0 F
2-3s
500 g

To Order a Coil choose Coil Ref + Voltage Code, example: 495910 for 28VDC = 495910N7

514

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

INTRINSICALLY SAFE
ELECTRICAL PARTS
"ia"

9.0

ZONE 0/20

496565 ELECTRICAL PARTS "BOOSTER"


"IS" 37 mm
This coil can be mounted with every Parker ATEX solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where
explosion-proof protection Ex ia IIC T4 to T6 is required.
Benefits: Rotatable 360 fibreglass-reinforced plastic housing (class H).
Solenoid coil, rectifier (silicium diodes), fuses and varistor protection are
completely encapsulated into the coil housing by epoxy resin for shock
and corrosion protection.
The plastic housing is delivered with M20 x 1.5 cable gland. Small size
for ease of mounting in confined space.
Reference

496565

Certicate
Coil group

LCIE 08 ATEX 6071 X - IECEx LCI 08.0030 X


9.0

Type of protection

Gas
Dust

Degree of protection
Ambiant temperature
Electrical connection
Minimum Courant of function
Minimum voltage
of function at 60C
Safety parameters
Maximum acceptable values:
Ui (V) / Ii (mA) / Pi (W)

II 1 G - Ex ia IIC - T6 / T5 / T4
II 1 D - Ex ta IIIC - T80 / T95 T130C

II 1 G - Ex ia IIB - T6 / T5 / T4
II 1 D - Ex ta IIIC - T80 / T95 T130C

IP67
- 40C to +65C / +75C / +80C
The application might also be limited by the temperature range of the valve.
Cable connection through a plastic cable gland M20 x 1.5 allowing use of cable diameter from 7 to 12 mm.
Additional earth connection possible with external screw terminal.
20 mA
28 VDC (N7)
28 V / 110 mA / 0.77 W
27 V / 120 mA / 0.81 W
26 V / 135 mA / 0.88 W
25 V / 150 mA / 0.94 W
24 V / 170 mA/ 1.02 W

28 V / 280 mA / 1.96 W
27 V / 320 mA / 2.16 W
26 V / 350 mA / 2.27 W
25 V / 390 mA / 2.43 W
24 V / 430 mA/ 2.58 W

Line check
Apparent Impedance Typ.
Apparent Inductance
Apparent Capacitance

4 mA or 5 VDC max
Attraction ~ 600 - Holding ~ 570
0 mH
0 F

Response Time Typ.


Weight

2-4s
500 g

To Order a Coil choose Coil Ref + Voltage Code,


example: 496565 for 13VDC = 496565N7

515

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

492965 ELECTRICAL PART


"BOOSTER" "IS" 50 mm
This coil can be mounted with every Parker ATEX solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where
explosion-proof protection Ex ia or ib IIC T6 is required.
Benefits: Rotatable 360 housing, epoxy-coated metal housing and cover.
Coil, electronic circuits and other elements required for intrinsic safety are
completely encapsulated in the housing with epoxy material for shock and
corrosion protection.
Small size for ease of mounting in confined space.
Reference

492965.01 - Stainless steel xation

Certicate
Coil Group

LCIE 02 ATEX 6066 X - IECEx LCI 07.0007 X


9.0

Type of protection
Degree of protection
Ambiant temperature
Electrical connection
Maximum supply voltage
Minimum
DC
Maximum
Power

ZONE 0/20

9.0

INTRINSICALLY SAFE
ELECTRICAL PARTS
"ia"

Line check
Coil resistance at 20C
Impedance
Apparent inductance
Apparent capacitance

Gas
Dust

II 1 G - Ex ia IIC - T6
II 1 D - Ex ta IIIC - T80C
IP66
- 40C to +65C
The application is limited also by the temperature range of the valve.
Cable connection through a plastic or stainless steel cable gland M20 x 1.5 allowing use of cable diameter
from 10 to 12 mm. Additional earth connection possible with external screw terminal.
28 VDC (N7) - 110 mA
0.3 W (avec 13 VDC)
2.3 W (avec 24 VDC)
Depending on applied voltage, IS barrier type and resistance of connected cable
4 mA or 5 VDC max
85
275 (with 13 VDC) - 260 (with 24 VDC)
0 mH
0 F

Response time
Weight

2-4s
500 g

To Order a Coil choose Coil Ref + Voltage Code, example: 492965.01 for 28VDC = 492965.01N7

Important
The intrinsically safe supply circuit should have enough capacity in all
environmental conditions to assure a minimum operating current of 29 mA
through the coil.
The minimal holding current is 20 mA.

For the barrier compatibility see the corresponding table in appendix section.

516

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

12.0

INTRINSICALLY SAFE
ELECTRICAL PARTS
"ia"
ZONE 0/20

482870.01 & 492335 "NEMA"


ELECTRICAL PARTS "IS" 50 mm
These coils can be mounted with every Parker ATEX solenoid valves
corresponding to the specied Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where an
explosion-proof protection Ex ia IIC or IIB T6 is required.
Benets: Rotatable 360 housing, polyamid with fibreglass housing and
cover. Coil, electronic circuits and other elements required for intrinsic
safety are completely encapsulated in the housing with epoxy material for
shock and corrosion protection.
Small size for ease of mounting in confined space.
Reference

482870.01

492335

Certicate
Coil Group

LCIE 02 ATEX 6024 X

LCIE - FM - CSA

Type of protection
Degree of protection
Ambiant temperature
Electrical connection

Power

Maximum supply voltage


Minimum
DC
Maximum

12,0
Gas
Dust

II 1 G - Ex ia IIC - T6
Cl. I, Div.I, Gr. A, B, C, D
Cl. II, Div.I, Gr. E, F, G
II 1 D - Ex ta IIIC - T80C
IP66
NEMA 4 - 4X
- 40C to +65C
+60C
The application is limited also by the temperature range of the valve.
Cable connection through a stainless steel cable gland M20 x 1.5 allowing use of cable diameter from 10 to 12 mm.
Additional earth connection possible with external screw terminal.
28 VDC (N7) - 280 mA
30 VDC (N7) - 100 mA
300 mW
3W
Depending on applied voltage, IS barrier type and resistance of connected cable

Coil resistance at 20C


Impedance
Apparent inductance
Apparent capacitance

295
345
0 mH
0 F

Weight

500 g

To Order a Coil choose Coil Ref + Voltage Code, example: 492335 for 30VDC = 492335N7

Important
The intrinsic safety supply circuit must have sufcient capacitance in all
ambient conditions to guarantee a minimum operating current in excess of
29 mA across the coil.
The minimum current for holding in the energised position is 20 mA

For the barrier compatibility see the corresponding table in appendix section.

517

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

488650.01 & 490885 "NEMA"


ELECTRICAL PARTS "IS" 50 mm
This coil can be mounted with every Parker ATEX solenoid valves
corresponding to the specied Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where
explosion-proof protection Ex ia or ib IIC T6 is required.
Benets: Rotatable 360 housing, polyamid with fibreglass housing and
cover. Coil, electronic circuits and other elements required for intrinsic
safety are completely encapsulated in the housing with epoxy material for
shock and corrosion protection.
Small size for ease of mounting in confined space.
Reference

488650.01
LCIE 02 ATEX 6024 X

Certicate
Coil Group

Degree of protection
Ambiant temperature
Electrical connection
Maximum supply voltage
DC

490885
LCIE / FM / CSA
7.0

Type of protection

Power

ZONE 0/20

7.0

INTRINSICALLY SAFE
ELECTRICAL PARTS
"ia"

Minimum
Maximum

Gas
Dust

II 1 G - Ex ia IIC - T6
Cl. I, Div.I, Gr. A, B, C, D
Cl. II, Div.I, Gr. E, F, G
II 1 D - Ex ta IIIC - T80C
IP66
NEMA 4 - 4X
- 40C to +65C
60C
The operating temperature of the valve/coil can be limited by that of the valve.
Cable entry through a cable gland M20 x1.5. Screw terminals for leads 3 x 1.5 mm max.
Additional earth connection possible with external screw terminal
28 VDC (N7) - 110 mA
30 VDC(N7) - 100 mA
The minimum operating voltage at maximum 60C is 11.5 VDC.
300 mW
3W
Dependent on the applied voltage, type of barrier IS and the resistance of the connected cable

Coil resistance at 20C


Impedance
Apparent inductance
Apparent capacitance

295
345
0 mH
0 F

Weight

500 g

To Order a Coil choose Coil Ref + Voltage Code, example: 490885 for 30VDC = 490885N7

Important
The intrinsically safe supply circuit should have enough capacity in all
environmental conditions to assure a minimum operating current of 29 mA
through the coil.
The minimal holding current is 20 mA.

For the barrier compatibility see the corresponding table in appendix section.

518

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

7.0

INTRINSICALLY SAFE
ELECTRICAL PARTS
"ia"
ZONE 0/20

488660.01 & 490890 " NEMA"


ELECTRICAL PARTS "IS" 50 mm
These coils can be mounted with every Parker ATEX solenoid valves
corresponding to the specied Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where
explosion-proof protection Ex ia or ib IIC T6 is required.
Benets: Rotatable 360 housing, epoxy-coated metal housing and
cover. Coil, electronic circuits and other elements required for intrinsic
safety are completely encapsulated in the housing with epoxy material
for shock and corrosion protection.
Small size for ease of mounting in confined space.
Reference

488660.01
LCIE 02 ATEX 6024 X

Certicate
Coil Group

7.0

Type of protection
Degree of protection
Ambiant temperature
Electrical connection

Power

Maximum supply voltage


DC

490890
LCIE / FM / CSA

Minimum
Maximum

Gas
Dust

II 1 G - Ex ia IIC - T6
Cl. I, Div.I, Gr. A, B, C, D
Cl. II, Div.I, Gr. E, F, G
II 1 D - Ex ta IIIC - T80C
IP67
NEMA 4 - 4X
- 40C to +65C
+60C
The operating temperature of the valve/coil can be limited by that of the valve
Cable entry through a cable gland M20 x1.5. Screw terminals for leads 3 x 1.5 mm max.
Additional earth connection possible with external screw terminal.
28 VDC - 110 mA (N7)
30 VDC - 100 mA (N7)
The minimum operating voltage at maximum 60C is 11.5 VDC.
300 mW
3W
Dependent on the applied voltage, type of barrier IS and the resistance of the connected cable

Coil resistance at 20C


Impedance
Apparent inductance
Apparent capacitance

295
345
0 mH
0 F

Weight

500 g

To Order a Coil choose Coil Ref + Voltage Code, example: 490890 for 30VDC = 490890N7
Important
The intrinsic safety supply circuit must have sufcient capacitance in all
ambient conditions to guarantee a minimum operating current in excess of
29 mA across the coil.
The minimum current for holding in the energised position is 20 mA.

For the barrier compatibility see the corresponding table in appendix section.

519

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSION PROOF
ELECTRICAL PARTS
COIL GROUP

488670.01 - ELECTRICAL PARTS "IS" 50 mm


This coil can be mounted with every Parker ATEX solenoid valves
corresponding to the specified Coil Group.
See column "Coil Group" within valve pages.
Application: Control of solenoid valves in dangerous areas where
explosion-proof protection Ex ia or ib IIC T6 is required.
Benefits: Rotatable 360 housing, epoxy-coated metal housing and
cover. Coil, electronic circuits and other elements required for intrinsic
safety are completely encapsulated in the housing with epoxy material
for shock and corrosion protection.
Small size for ease of mounting in confined space.
Reference

488670.01

Certicate
Coil group

LCIE 02 ATEX 6024 X


7.0

Type of protection
Degree of protection
Ambiant temperature
Electrical connection
Maximum supply voltage
Power

ZONE 0/20

7.0

INTRINSICALLY SAFE
ELECTRICAL PARTS
"ia"

DC

Minimum
Maximum

Gas
Dust

II 1 G - Ex ia IIC - T6
II 1 D - Ex ta IIIC - T80C
IP65
- 40C to +65C
The operating temperature of the valve/coil can be limited by that of the valve
Cable entry through a cable gland M20 x1.5. Screw terminals for leads 3 x 1.5 mm max.
Additional earth connection possible with external screw terminal.
28 VDC (N7) - 110 mA
The minimum operating voltage at maximum 60C is 11.5 VDC.
300 mW
3W
Dependent on the applied voltage, type of barrier SI and the resistance of the connected cable

Coil resistance at 20C


Impedance
Apparent inductance
Apparent capacitance

295
345
0 mH
0 F

Weight

500 g

To Order a Coil choose Coil Ref + Voltage Code, example: 488670.01 for 28VDC = 488670.01N7

Important
The intrinsic safety supply circuit must have sufcient capacitance in all
ambient conditions to guarantee a minimum operating current in excess of
29 mA across the coil.
The minimum current for holding in the energised position is 20 mA.

For the barrier compatibility see the corresponding table in appendix section.

520

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

HOUSINGS

TABLE OF CONTENT
INTRODUCTION
Index by Coil Reference................................................................................................................................................................................. 446
Index by Coil Group ......................................................................................................................................................................................... 448
Index for Explosion Proof Electrical Parts............................................................................................................................................. 450
List of Coil Groups ............................................................................................................................................................................................ 451

COILS
Coils for DIN plug connection ..................................................................................................................................................................... 454
Coils with flying leads...................................................................................................................................................................................... 477
Coils with screw terminal............................................................................................................................................................................... 482
Coils with ISO-DIN connector..................................................................................................................................................................... 488

EXPLOSION PROOF ELECTRICAL PARTS


Level of protection "nc AC

.......................................................................................................................................................................... 490

Level of protection "db" ................................................................................................................................................................................. 498


Level of protection "mb"................................................................................................................................................................................ 499
Level of protection "db mb"......................................................................................................................................................................... 504
Level of protection "eb" ................................................................................................................................................................................. 509
Level of protection "ia" ................................................................................................................................................................................... 513

HOUSINGS ....................................................................................................................................................................................................... 522

COIL ACCESSORIES .............................................................................................................................................................................. 526

EXPLOSIVE ENVIRONMENTS ........................................................................................................................................................ 528

COIL APPENDICES
Guidance chart for IS-Barriers.................................................................................................................................................................... 538
Table of voltage codes for coils and electrical parts ....................................................................................................................... 540
521

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

HOUSINGS
HOUSING

4270

COIL STANDARD HOUSING


WITH SCREW TERMINALS

Standard housing:

4270

Reference:
Material:

Epoxy-coated steel with cataphoresis traitement

Degree of protection:

IP according to IEC/EN 60529


IP 10 with armoured conduit
IP 44 with cable gland

Electrical connection:

Can be made with armoured conduit or cable gland


M12x1.5. Parts No. 484092 and 484093 to be ordered
separately.
Grounding connection by screw M3 on the inside
of housing base plate.

Weight:

120 g

Benefits:
This metal housing offers the ideal protection against shocks and corrosion- rotatable 360 - easy mounting
in confined spaces - single-nut mounting - light weight - simplifies conversion of existing equipment to other
requirements.
Application:
The majority of the Lucifer valves can be fitted with this standard housing, and can be mounted with several
compatible Lucifer coils grupe.
Compatible coils:
O 481000 - Standard Coil
8W
Class F (155C)
O 483520 - Double-Frequency Coil
9W
Class F (155C)
O 481044 - Standard High-Power Coil
14 W
Class F (155C)
O 485100 - Standard High-Temperature Coil
8W
Class H (180C)
O 486265 - High-Temperature and High-Power Coil
14 W
Class H (180C

522

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

HOUSINGS
HOUSING

4269

HOUSING FOR BISTABLE


(IMPULSE) COILS

Housing for bistable coil:

4269

Reference:
Material:

Epoxy-coated steel

Degree of protection:

IP according to IEC/EN 60529


IP 10 with armoured conduit
IP 44 with cable gland

Electrical connection:

Can be made with armoured conduit or cable gland


M12x1.5. Parts No. 484092 and 484093 to be ordered
separately.
Grounding connection by screw M3 on the inside
of housing base plate.

Weight:

120 g

Benefits:
This metal housing offers the ideal protection against shocks and corrosion- rotatable 360 - easy mounting
in confined spaces - single-nut mounting - light weight - simplifies conversion of existing equipment to other
requirements.
Application:
This housing is specially designed for group 706 coils and can be mounted only with valves controlled by
electrical impulses.
Compatible coils:
O 484990 - Impulse coil for AC
11 W
Class F (155C)
O 485400 - Impulse coil for DC
13 W

Class F (155C)

523

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

HOUSINGS
HOUSING

4538

WATERPROOF AND DUSTPROOF


HOUSING

Waterproof housing:

4538

Reference:
Material:
Degree of protection:

Galvanized passivated steel

Electrical connection:

Cable connection by cable gland M12x1.5 according to


DIN 46320. Cable with outer diameter 6.5 - 13.5 mm can
be simply sealed using a rubber gland with resilient sealing
rings.

IP according to IEC/EN 60529


IP 67 with cable gland

The enclosure is internally and externally tted with


grounding and earthing screw terminals.

Weight:

180 g

Benefits:
This enclosure is dust- and waterproof. It corresponds to the degree of "International Protection" IP 67
according to IEC / EN 60529. Corrosion resistant, the metal housing offers good protection for the coil against
shocks and other outside influences - rotatable 360 - easy mounting in confined spaces - easy access to the
screw terminals - single-nut mounting - light weight - simple conversion of existing electrical equipment to
other requirements without interruption of fluid passage in the valve.
Application:
This housing can be equipped with several coils of our programme, like the standard, double-frequency and
magnetic latch coils.
Compatible coils:
O 481000 - Standard Coil
8W
Class F (155C)
O 483520 - Double-Frequency Coil
9W

Class F (155C)

O 484990 - Impulse Coil for AC


11 W
Class F (155C)
O 485400 - Impulse Coil for DC
13 W
Class H (180C)

524

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

HOUSINGS
HOUSING

8520

WATERPROOF HOUSING
FOR HIGH-TEMPERATURE COILS

Waterproof housing:

8520

Reference:
Material:
Degree of protection:

Galvanized passivated steel

Electrical connection:

Cable connection by cable gland M12x1.5 according to


European standards. Cable with outer diameter 6.5 - 13.5
mm can be simply sealed using a rubber gland with resilient
sealing rings.
The enclosure is internally and externally tted
with grounding and earthing screw terminals.

Weight:

180 g

IP according to IEC/EN 60529


IP 67 with cable gland

Benefits:
This enclosure is dust- and waterproof. It corresponds to the degree of "International Protection" IP 67
according to IEC / EN 60529. Corrosion resistant, the metal housing offers good protection for the coil against
shocks and other outside influences - rotatable 360 - easy mounting in confined spaces - easy access to the
screw terminals - single-nut mounting - light weight - simple conversion of existing electrical equipment to
other requirements without interruption of fluid passage in the valve.
Application:
The majority of the Lucifer valves can be fitted with this housing and can be mounted with several
compatible Lucifer coils for high temperature (14 W, 8 W Class F or H).
Compatible coils:
O 481044 - High Power Coil
14 W
Class F (155C)
O 486265 - High Power Coil
14 W
Class H (180C)
O 485100 - Coil for High Temperature
8W
Class H (180C)

525

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COIL
ASSEMBLY KITS
ACCESSORIES

22 mm
32 mm

COIL ASSEMBLY KITS

COIL ASSEMBLY KIT FOR 22 mm COIL


The coil assembly kit corresponds to the numbering system for Lucifer
valve housings (Valve - housing - coil - voltage).
It is composed of a nameplate with the details of the valve type, a washer
and a nut to secure the 22 mm coil to the valve.
Caution: these coil assembly kits for 22 mm coils are not adapted for
high flow valves, ask your distributor for the adapted kit.
Reference

Specication

Application

8993

Standard - aluminium nameplate - passivated washer and nut - pressure indication in [bar]

Standard valves

8993.03

Standard - aluminium nameplate - passivated washer and nut - pressure indication in [psi]

Standard valves

8122

Special - aluminium nameplate - stainless steel washer and nut - pressure indication in [psi]

316L St. Steel Valves

8567

Special - knurled at aluminium nut

Water valves- series 321K3

COIL ASSEMBLY KIT FOR 32 mm COIL


The coil assembly kit corresponds to the "housing" of Lucifer valve
numbering system (Valve - housing - coil - voltage).
It is composed of a nameplate giving details of the valve type, a round
washer and a nut to ensure the fixing between 32 mm coil and the valve.

Reference

Specication

Application

2995

Standard - Aluminium nameplate - Passivated iron washer and nut - Pressure indication in [bar]

2995.03

Standard - Aluminium nameplate - Passivated iron washer and nut - Pressure indication in [psi]q

UL / CSA valves

8132

Special - Aluminium nameplate - Stainless steel washer and nut - Pressure indication in [psi]

316L St. Steel valves

2161

Special - Aluminium nameplate - Passivated iron washer and nut - Pressure indication in [bar]

Transportation valves

2168

Special AD Blue - Aluminium nameplate - Passivated iron washer and nut - Pressure indication in [bar]

Transportation valves

2169

Special AD Blue - Aluminium nameplate - Passivated iron washer and nut - Pressure indication in [bar]

Transportation valves

526

Standards valves

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COIL
ACCESSORIES

ACCESSORIES

DIN PLUG CONNECTOR ACCORDING TO EN 175301-803 -B


No. 481043
Electrical connection suitable for all 22 mm coils
(e.g. 488980, 481180)

DIN PLUG CONNECTOR ACCORDING TO EN 175301-803 - A


No. 486586 for standard version
No. 492645 for high temperature version
Electrical connection suitable for all 32 mm coils
(e.g. 481865, 492425)

STAINLESS STEEL ASSEMBLY KIT


Nut No. 482213 M14 x 1+ Ring No. 482214 +
O-Ring No. 483917
Coil assembly kit for offshore electrical parts
(e.g. 482870.01, 483330.01, 492210, 492965.01, 496565, 496700)

PLASTIC NUT WITH METAL INSERT


No. 8886
For Oil & Gaz electrical parts
(e.g. 492965.01, 492300, )

CABLE GLAND
No. 492398 - Pg 13.5 -Ex eb II
No. 493841 - M20x1.5 - Ex ia IIC
Electrical connection and mooring cable with 6 to 12 mm diameter, for electrical
parts approved "eb mb" or "ia"
(e.g. 492190, 492965.)
CABLE GLAND
No. 493426 - 1/2"-14 NPT
Electrical connection and mooring cable with 6 to 12 mm diameter, for flameproof
approved electrical parts
(e.g. 493640)

527

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSIVE
ENVIRONMENTS

INTRODUCTION

Current European regulations concerning electrical equipment for potentially explosive environments are based on
optional and partial European directives which require regular modification in the form of application or adaptation
directives in order to keep pace with technical developments.
The basic European text in this field, directive 76/117/EC, which allow the free circulation of goods within the
European Union, provides the general framework for the present regulations.
Electrical equipment for use in potentially explosive environments is certified by a government-approved body when
it meets relevant European standards (EN 60079-0 and upwards) covering each type of protection (db, ia, eb, m, p,
etc). Such equipment is then issued with a an EC type examination certicate, entitling it to carry the distinctive
marking.
This mark opens the way for trading within the European Union and occasionally beyond.
Although largely beneficial, it has revealed certain drawbacks, notably a lack of flexibility and the absence of a global
concept for safety. It has now been completely revised by the new European directive 94/9/EC from March 23,
1994.
The EC type examination certificate to harmonised standards obtained in compliance with previous directives will
remain valid until June 30, 2003, but their validity will cover only conformity to the harmonised standards specified
in these directives.

EUROPEAN MEMBER COUNTRIES

528

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSIVE
ENVIRONMENTS

DEFINITIONS
EXPLOSIVE ENVIRONMENTS
Mixture with air, under atmospheric conditions, of flammable substances in the form of gases, vapours, mists or
dusts in which, after combustion has occurred, combustion spreads to the entire unburned mixture.

HAZARDOUS AREAS
A hazardous area is an area in which an explosive gas environment is present, or may be expected to be
present, in quantities such as to require special precautions for construction, installation and use of electrical
apparatus.

INGREDIENTS FOR AN EXPLOSION


When combustible materials are mixed with air, an explosive mixture is produced. Danger of explosion therefore
exists wherever these hazardous materials are handled: such a condition is to be found on the biggest chemical
plant as well as at the smallest filling station.
Nowadays with the use of electronic and electrical instrumentation in process control, the risk of combustion
by electrical energy has increased sharply.
To protect personnel and expensive equipment special precautions should be taken to prevent
combustion of those dangerous substances. Conditions likely to ignite explosive mixtures are as follows:
O When combustible materials are mixed with air, an explosive mixture is produced. Danger of explosion
therefore exists wherever these hazardous materials are handled: such a condition is to be found on the
biggest chemical plant as well as at the smallest filling station.
O Nowadays with the use of electronic and electrical instrumentation in process control, the risk of
combustion by electrical energy has increased sharply.
O To protect personnel and expensive equipment special precautions should be taken to prevent combustion
of those dangerous substances. Conditions likely to ignite explosive mixtures are as follows:

529

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSIVE
ENVIRONMENTS

DEFINITIONS
ZONES
The hazardous areas are classified in zones based on the frequency of the occurrence and the duration of an
explosive gas environment as follows:

Zone 0 (20)

Zone 1 (21)

Zone 2 (22)

An area in wich an explosive


gas (dust) atmosphere is present
CONTINUOUSLY or is present for
LONG PERIODS (~1000 h/y).

An area in wich an explosive


gas (dust) atmosphere is present
LIKELY TO OCCUR in normal
operation (~10 to 999 h/y).

An area in wich an explosive


gas (dust) atmosphere is not
LIKELY TO OCCUR and if it does
occur it will exist for short period
only (~1 to 10 h/y).

Mode of protection: ia - ma - px -

Mode of protection: db - eb - ib - mb - px -

Mode of protection: n - mc - ic - pz -

CLASSIFICATION OF HAZARDOUS LOCATION


Explosive
Environment

Continuous
Presence

Intermittent Presence

Occasional Presence

(normal operation conditions)

(abnormal operation)

IEC

Zone 0 (gas)
Zone 20 (dust)

Zone 1 (gas)
Zone 21 (dust)

Zone 2 (gas)
Zone 22 (dust)

Europe

Zone 0 (gas)
Zone 20 (dust)

Zone 1 (gas)
Zone 21 (dust)

Zone 2 (gas)
Zone 22 (dust)

Cl. I Div. 1 (gas)


Cl. II Div. 1 (dust)
Cl.III Div. 1 (bres)

Cl. I Div. 1 (gas)


Cl. II Div. 1 (dust)
Cl.III Div. 1 (bres)

Cl. I Div. 2 (gas)


Cl. II Div. 2 (dust)
Cl.III Div. 2 (bres)

Canada (CEC)
USA (NEC)

(CEC): Code Canadien dElectricit / (NEC): National Electrical Code

Example:

530

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSIVE
ENVIRONMENTS

DEFINITIONS
CLASSIFICATION OF HAZARDOUS LOCATION
Category

Fault protection

Atmosphere

Zone

Example of protections

G (Gas)
D (Dust)

0
20

"ia", "ma", "px"


or "ia-ma", "db/eb"

G (Gas)
D (Dust)

1
21

EC Type examination by Notied Body annex III

2 types of protection or
2 indpendant faults

Very high level

EC Type examination by Notied Body annex III


One type of protection

High level

Habitual frequent malfunction

One type of protection


lb, db, mb, eb, py, o,

Internal production inspection EC declaration of conformity

G (Gas)
D (Dust)

Required level of protection

Normal

2
22

n, ic, pz,
A, C, L, P, R

Classication of Hazardous Location


Group

I
IIA
IIB
IIC

Gas Reference
Methane
Propane
Ethylene
Hydrogen / Acethylene

Surface Temperature Classes


Class Temperature

Max. Temperature

T1

450C

600

560C Hydrogen

Gas & Ignition Temperature

T2

300C

500

537C Methane

T3

200C

400

425C Ethylene

T4

135C

300

T5

100C

200

T6

85C

100

305C Acetylene
210C Kerozene
160C Ethylether
95C Carbon disulphide

T1
T1
T2
T2
T3
T4
T6

0
531

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSIVE
ENVIRONMENTS

MODE OF PROTECTION USED


BY PARKER LUCIFER
MODES DE PROTECTION
Concept
Flameproof enclosure
Encapstulation
Increased Safety
Intrinsic Safety
Pressurized apparatus
Concept Cat. 3 apparatus

Gas

Code

Zones

Dust

Gas

db

tb

1/2

Dust
21/22

ma / mb / mc

tb / tc

0/1/2

20/21/22

eb

1/2

ia / ib / ic

ta / tb / tc

0/1/2

20/21/22

px / py / pz

pD

1/2

21/22

nA
nL
nR
nC

2
2
2
2

532

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSIVE
ENVIRONMENTS

STANDARDS AND TYPE


OF PROTECTION
APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES
EQUIPMENT GROUP II
EPL

Ga

Standards
EN / IEC

Protection

Title

60079-0

General requirements

60079-11

ia

Intrinsic safety

60079-18

ma

60079-28

Gb

Encapsulation

60079-26

Equipment with equipment protection level (EPL) Ga (Zone 0)


op is

Protection of equipment and transmission systems using optical radiation

60079-1

db

Flameproof enclosures

60079-2

p, px, py

Pressurized enclosures

60079-5

Powder lling

60079-6

Oil immersion

60079-7

eb

Increased safety

60079-11

ib

Intrinsic safety

60079-18

mb

Encapsulation

60079-25

Intrinsically safe systems

60079-27
60079-28

Gc

Fieldbus intrinsically safe concept (FISCO)


op is
op pr
op sh

Protection of equipment
and transmission systems using optical radiation

60079-11

Ic

Intrinsic safety

60079-18

mc

Encapsulation

60079-15

nA

Non sparking

60079-15

nR

Restricted breathing enclosure

60079-15

nL

Limited energy (only old edition)

60079-15

nC

Equipment producing operational sparks

60079-2

pz

Pressurized enclosures

60079-27
60079-28

Concept de rseau de terrain de scurit intrinsque (FISCO)


op is
op pr
op sh

Protection of equipment
and transmission systems using optical radiation

EPL = Equipement Protection Level

533

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSIVE
ENVIRONMENTS

STANDARDS AND TYPE


OF PROTECTION
ELECTRICAL EQUIPMENT FOR USE IN AREAS
WITH COMBUSTIBLE DUST - EQUIPMENT GROUP III
EPL

Standards
EN / IEC
60079-0

General requirements

Da

60079-31
60079-11
61241-18

ta
ia
ma

Protection by enclosure
Protection by intrinsic safety (iaD IEC/EN 61241-11)
Protection by encapsulation

Db

60079-31
60079-11
60079-18
IEC 61241-4

tb
ib
mb
pD

Protection by enclosure
Protection by intrinsic safety (ibD IEC/EN 61241-11)
Protection by encapsulation
Type of protection "pD"

Dc

60079-31
60079-11
60079-18
IEC 61241-4

tc
ic
mc
pD

Protection by enclosure
Protection by intrinsic safety
Protection by encapsulation
Type of protection "pD"

Protection

Title

EPL = Equipement Protection Level

NON ELECTRICAL EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERE


Standards

Protection

Title

EN 13463-1

Basic method and requirements

EN 13463-2
EN 13463-3
EN 13463-5
EN 13463-6
EN 13463-7
EN 13463-8

fr
db
c
b
p
k

Protection by ow restricting enclosure


Protection by ameproof enclosure
Protection by constructional safety
Protection by control of ignition source
Protection by pressurized enclosure
Protection by liquid immersion

ZONES AND EQUIPEMENT PROTECTION LEVEL (EPL)


Zone
0
1
2

Gas

EPL

Zone
20
21
22

Ga
Ga and Gb
Ga, Gb and Gc

Dust

EPL
Da
Da and Db
Da, Db and Dc

CATEGORIES AND EQUIPEMENT PROTECTION LEVEL (EPL)


Categories
1
2
3

Gas

Dust

Safety

Ga
Gb
Gc

Da
Db
Dc

Very high
High
Normal

534

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSIVE
ENVIRONMENTS

EXAMPLES OF MARKING
ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES
EQUIPMENT GROUP II

Ex de IIC T5 Gb
Equipment Groups
(Dust)
IIA
IIB
IIC

Aceton, ethane, benzene,


petrol, butane, propane,
methane
Ethylene, town gas
Hydrogen, acetylene

Temperature
Class
T1
T2
T3
T4
T5
T6

Ignition
Temperature of
Gas or Vapour

Maximum admissible
surface temperature for
permanently hot surfaces

> 450C

440C

> 300C

290C

> 200C

195C

> 135C

130C

> 100C

95C

> 85C

80C

Zone
0
1
2

Equipment
Protection Level (EPL)
Ga
Gb and Ga
Gc, Gb and Ga

ELECTRICAL EQUIPMENT FOR USE IN AREAS


WITH COMBUSTIBLE DUST - EQUIPMENT GROUP III
Surface Temperature Max.

Ex tb IIIC T95C Db
Ex tb IIIC T95C
Equipment Groups
(Dust)
IIIA
IIIB
IIIC

Zone

Fibres

20

Non-conductive dust

21

Conductive dust

22

535

Equipment
Protection Level (EPL)
Da
Db and Da
Dc, Db and Da

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSIVE
ENVIRONMENTS

WHAT ABOUT THE DIRECTIVE ?


(94/9/EC - 1994-03-23)

WHAT ABOUT THE DIRECTIVE ? (94/9/EC - 1994-03-23)


In keeping with the "new approach", the new directive lays down the framework for a total harmonization of
regulations covering this field.
It makes no direct references to standards but sets out the essential health and safety requirements to be met
and introduces the CE marking.

ATEX 100 A DIRECTIVE - NEW APPROACH


GROUP I

GROUP II

DIRECTIVE

(mines)

(surface)

(machines)

82/130/CEE
88/035/CEE
91/269/CEE
94/044/CEE

76/117/CEE
79/196/CEE
84/047/CEE
88/571/CEE
90/487/CEE
94/026/CEE

98/37/CE
(ESR 1.5.7)

94/9/EC

THE FRAMEWORK OF THE DIRECTIVE


The main principles of the new directive can be summarized as follows:
O It applies to electric and non-electric equipment.
O It defines essential health and safety requirements.
O It takes into consideration all potential hazards equipment may cause, in particular at design and production
level.
O The one directive applies to both mines susceptible to fire damp and surface industries.
O It stresses the importance of equipment being used in accordance with its intended purpose.
O It recognises The European Standards Committee CEN and the European Committee for Electrotechnical
Standardisation CENELEC as competent bodies to fix the required harmonised standards.
O It provides for the contribution of labour and management.
O It defines procedures for assessing conformity to essential requirements, on the basis of modules which
qualify equipment to carry the CE mark of conformity.

APPLICATIONS
The directive applies to the industrial field and concerns the following equipment:
O Equipment (machines, apparatus, etc.)
O Protective systems (discharge devices, explosion suppression devices, etc.)
O Components (parts with no autonomous function, terminals, etc.)
O Safety devices, controlling devices and regulating devices intended for use outside potentially
explosive environments but required for safety with respect to explosions (relays, barriers, pressure
switches, thermostats, etc.)
536

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

EXPLOSIVE
ENVIRONMENTS

WHAT ABOUT THE DIRECTIVE ?


(94/9/EC - 1994-03-23)

EXCLUDED FROM THE SCOPE OF THE NEW DIRECTIVE


The following equipment falls outside the scope of the new directive:
O Medical devices intended for use in a medical environment.
O Equipment and protective systems relating only to the risk of explosion
of unstable chemical substances (explosives, etc.)
O Equipment intended for use in domestic and non-commercial environments.
O Personal protective equipment covered by directive 89/686/EC.
O Seagoing vessels and mobile offshore units.
O Means of transport, except for vehicles intended for use in a potentially explosive environment.

APPLICATION DATES
ATEX 100A DIRECTIVE - NEW APPROACH

94/9/EC
Application dates
Transposition to national law

1/9/1995

Application (optional)

1/3/1996

Application (total)

1/7/2003

POTENTIAL IGNITION SOURCES AND OTHER HAZARDS


TO BE CONTROLLED
The following all represent potential hazards:
O Various sources of ignition, such as sparks, flames, electric arcs, high surface temperature, acoustic energy,
optical radiation or electromagnetic waves.
O Static electricity.
O Pressure compensation operations.
O Disturbance from external sources, such as changing environmental conditions, extraneous voltage,
humidity, vibration or contamination.
Provision is also made for specific requirements governing devices used to provide additional equipment safety.
These requirements necessitate detailed analysis to asses the operational reliability of such devices and their
interaction with other components connected with the equipment.
537

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COIL
APPENDICES

GUIDANCE CHART FOR IS-BARRIERS


Manufacturer

Reference

IS Standard Electrical Parts

Ex

Ex ia IIC T6 Ex ia IIC T6 Ex ia IIC T6


Ex ia
Ex ia IIB T6
488650.01/02
490885
483580.01/03
490880
482160,01
488660,01
490890
483960.01/03 (493997)
488670,01
(490895)
LCIE/AUS LCIE/FM/CSA LCIE/AUS LCIE/FM/CSA
LCIE

A puissance 3
ABB

BRADLEY
COOPER

ELCON

GEORGIN

Hima

MTL

Pepperl
& Fuchs

NAEV 22-140
NAEV 26-100
V171132-54
V171132-55
V171132-61
DO 890
S900-DO4-EX
FEX-EX 24V
LB 2101
LB 2105
LB 2112
1881 / 1882
471 / 472
2871/2872
2874/2875/2876
AVB 122
AVB 125
AVB 128
F3328A
F3335
H4007
728P, 7128P,
7728P
728, 7028,
7128, 7728
3021, 4021,
4021S
3022
4023
4024
4025

ia
ia
ib
ib
ia
ib
ib
ia
ia
ia
ia
ia
ia
ia
ia
ia
ia
ia
ib
ib
ib

ia

ia

5021, 5023, 5024

ia

5025
4521 / 4523 /
4524
5521 / 5523 /
5524
Z 728
Z 779
EGA-041-3
KFD2-SD-EX1.36
KFD2-SL-EX1.36
KFD2-SD-EX1.48
KFD2-SL-EX1.48
KFD2-SLEX1.48.90A
KFD2-SLEX1.48.90A

ia

ia
ia
ia
ia
ia

ia
ia
ia
ia
ia
ia
ia
ia
ia
ia

IS Booster Electrical Parts


Ex ia IIC T6
482870,01

Ex ia
492335

LCIE

LCIE/FM/CSA

LCIE

LCIE

LCIE

ia

KFD2-SL2-EX1.LK

ia

ia
ia
ib
ib

KFD2-SL2-EX2
KSD2-BO-EX
RSD-BO-EX4
RSD-VO-EX8

538

Ex ia IIC T6
495910

Ex ia IIC T6 Ex ia IIC T6
492965.01/02
496565

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COIL
APPENDICES

GUIDANCE CHART FOR IS-BARRIERS


Manufacturer

Reference

IS Standard Electrical Parts

Ex

Ex ia IIC T6 Ex ia IIC T6 Ex ia IIC T6


Ex ia
Ex ia IIB T6
488650.01/02
490885
483580.01/03
490880
482160,01
488660,01
490890
483960.01/03 (493997)
488670,01
(490895)
LCIE/AUS LCIE/FM/CSA LCIE/AUS LCIE/FM/CSA
LCIE

SIEMENS

STAHL

Turck

BARTEC

5RD00-0AB0
7RD00-0AB0
7RD01-0AB0
7RD10-0AB0
7RD11-0AB0
7RD20-0AB0
7RD21-0AB0
9001/01-252100-14
9001/01-280100-10
9001/01-280110-10
9002/13-280100-04
9311/52-11-10
9111/63-11-00
9351/10-15-10
9351/10-16-10
9351/10-17-10
9381/10-187050-10
9381/10-246055-10
9381/10-246070-10
9465/12-04-11
9475/12-04-21
9475/12-04-31
9475/12-08-41
9475/12-08-51
9475/12-08-61
MK72-S01-EX
MK72-S02-EEX
MK72-S04-EEX
MK72-S05-EEX
MK72-S06-EEX
MK72-S07-EEX
MK72-S09-EEX
MK72-S12-EEX
MC72 - 41
MC72 - 43
MC72 - 44
07-73312301/1000
07-73312301/1100

IS Booster Electrical Parts


Ex ia IIC T6
482870,01

Ex ia
492335

Ex ia IIC T6 Ex ia IIC T6
492965.01/02
496565

Ex ia IIC T6
495910

LCIE

LCIE/FM/CSA

LCIE

LCIE

ib
ia
ia
ia
ia
ia
ia

ia

27 V

27 V

24 V

24 V

24 V

ia

ia

24 V

24 V

27 V

27 V

24 V

24 V

24 V

17 V

17 V

17 V

ia
ia
ia
ia
ia

25 V
25 V
-

15 V
15 V

15 V
15 V

15 V
15 V

ib

ib

25 V
25 V
-

ia

ib

ib
ia/ib
ia/ib
ia/ib
ib
ia/ib
ib
ib
ib
ib
ib
ib
ia
ia
ia
ia
ia

ia
ia

539

LCIE

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COIL
APPENDICES

TABLE OF VOLTAGE CODES FOR COILS


AND ELECTRICAL PARTS
This table is showing the most commonly used voltage codes, for other voltages, please ask us.

115/60

110/50-120/60

100/50-115/60

110-115/60

110-115/50-60

O
O

110/50-60

110/50

110-115/50 120/60

110-115/50

100/50-60

O
O
O
O
O

100/50

O
O
O
O
O

196 DC

2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
-

110 DC

1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.2
1.2
1.2
1.3
1.3
1.3
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
3.0
3.0

C7 E6 P1 A5 0A S5 P2 1P 6J 0P P3 K8

48 DC

481045
481180
481530
482605
482606
483590
488143
488980
492912
495865
496131
496482
496637
WB4.5
WB5.0
WB8.0
481000
481865
482635
482725
483371
483510
483520
485100
488553
488947
491514
492070
492190
492453
492670
492726
493640
494040
495870
495875
495905
496081
496082
496110
HZ10
481044
483816
486265
492425
492727
495880
496155
HZ11
482730
482735

30 DC

Sub-Group
28 DC

Group

24 DC

Coil

12 DC

C1 C2 N7 L8 C4 C5

220 DC

VOLTAGE CODES

O
O

O
O

O
O
O

O
O
O
O
O
O

O
O

O
O

O
O
O
O

O
O
O

O
O
O
O

O
O
O

O
O
O
O

O
O

O
O

O
O

O
O

O
O

O
O

O
O

O
O

O
O
O

O
O
O
O
O

O
O

O
O
O
O
O
O
O
O
O
O
O
O
O

O
O
O
O
O

O
O
O
O
O

O
O

O
O
O

O
O

O
O

O
O
O
O
O
O

O
O
O
O
O

O
O
O
O
O
O
O
O
O

O
O
O
O

540

O
O

O
O
O
O

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COIL
APPENDICES

48/50-60

48/50

380/50-440/60

380/50-60

380/50

240/50-60

240/60

B8 Q1 A9 Q2 5P A4 S4

240/50

O
O
O

24/50-60

24/60

24/50

230/50-60

230/60

230/50

220-240/50

220/50-240/60

220-240/60

220-230/60

O
O
O

220-230/50-60

220-230/50

220/50-60

220/60

220/50

208-240/60

A7 B7 R5 3D 7J 3P 4K Q3 S6 F4 J3 P9 A2 B2 P0

208-230/60

200-230/60

200/50-60

12/50-60

12/50

A1 1W P6 S2

O
O

O
O

O
O

O
O
O
O

O
O
O
O

O
O

O
O

O
O

O
O
O

O
O
O

O
O

O
O

O
O

O
O

O
O
O

O
O

O
O

O
O
O

O
O
O

O
O

O
O
O
O
O
O

O
O
O
O
O

O
O
O

O
O

O
O
O

O
O

O
O

O
O

O
O

O
O

O
O
O
O
O
O

O
O

O
O

O
O

O
O

O
O
O
O
O
O
O
O

O
O

O
O
O

O
O
O

541

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COIL
APPENDICES

TABLE OF VOLTAGE CODES FOR COILS


AND ELECTRICAL PARTS
This table is showing the most commonly used voltage codes, for other voltages, please ask us.

115/60

110/50-120/60

100/50-115/60

110-115/60

110-115/50-60

O
O

110/50-60

O
O
O
O
O
O
O
O
O

110-115/50 120/60

O
O

110-115/50

O
O

110/50

100/50-60

100/50

O
O
O

C7 E6 P1 A5 0A S5 P2 1P 6J 0P P3 K8

196 DC

O
O
O
O
O
O

110 DC

48 DC

30 DC

4.0
4.0
4.0
6.0
6.0
6.0
6.0
7.0
7.0
7.0
7.0
7.0
7.0
8.0
9.0
9.0
9.0
10.1
10.1
10.1
10.1
10.1
10.2
10.2
11.0
11.0
12.0
12.0
13.0
13.0
14.1
14.1
14.2
20.1
20.1
20.1
20.1
20.2
20.2
20.2
20.2
21.0
21.0
22.0
22.0
22.0
23.0
24.0
24.0
24.0
24.0
24.0

28 DC

Sub-Group
24 DC

484990
485400
495915
482740
482745
495900
496125
483580.01
488650.01
488660.01
488670.01
490885
490890
495910
492210
492965.01
496565
492300
492310
496560
496800
496895
496555
496700
483270
483270.02
492335
482870.01
495294
496193
483541
483824
483764
YB09
YB12
ZB09
ZB12
ZB14
ZB16
ZH14
ZH16
JB14
JB16
KH09
KP10
KT09
XT09
D4
D5
LA
LB-LC
XS03

Group

12 DC

Coil

C1 C2 N7 L8 C4 C5

220 DC

VOLTAGE CODES

O
O
O
O
O
O

O
O

O
O
O
O
O

O
O

O
O
O
O
O
O
O
O
O

O
O

O
O

O
O

O
O

O
O
O
O

O
O

O
O
O

O
O
O

O
O

O
O

O
O
O

O
O
O
O

O
O
O
O

O
O

O
O
O
O

542

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

COIL
APPENDICES

48/50-60

48/50

380/50-440/60

380/50-60

380/50

240/50-60

O
O

O
O
O
O
O
O
O

O
O

O
O

O
O

O
O

O
O

O
O
O
O

240/60

B8 Q1 A9 Q2 5P A4 S4

240/50

24/50-60

24/60

24/50

230/50-60

230/60

230/50

220-240/50

220/50-240/60

220-240/60

220-230/50-60

220-230/60

220-230/50

220/50-60

220/60

220/50

208-240/60

A7 B7 R5 3D 7J 3P 4K Q3 S6 F4 J3 P9 A2 B2 P0

208-230/60

200-230/60

200/50-60

12/50-60

12/50

A1 1W P6 S2

O
O

O
O

O
O
O

O
O
O
O

O
O

O
O
O
O
O
O

543

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

TECHNICAL
INFORMATION

544

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

TECHNICAL
INFORMATION

TECHNICAL INFORMATION
ABOUT SOLENOID VALVES

545

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

TECHNICAL
INFORMATION

TECHNICAL INFORMATION
ABOUT SOLENOID VALVES
General Information
Solenoid valves are electro-mechanical devices used for interrupting or diverting the flow
of fluids by opening or closing one or more orifices.
The solenoid valve is a combination
of three basic components:
1. An electromagnet consisting of a solenoid
(windings) and a magnetic yoke.
2. A pilot with a moveable plunger (which,
in some cases directly opens and closes
the valve).
3. A valve body with an orifice opened
or closed by plunger or diaphragm
to enable or prevent
ow
p
fl
flow
of the medium.
m
m.

1. Solenoid

2. Pilot

3. Valve body

Operating principles
The term solenoid refers to operator and coil, also known as pilot or magnetic actuator.
The coil consists of copper wire wound on a support reel. When electric current is applied into the coil,
magnetic flow lines are generated which are stronger in the coil center.
This magnetic flow raises the moveable plunger in the coil until it brings it into contact with the pole
piece. The valve body has an orifice through which the fluid flows when the valve is open.
The moveable plunger has an integral seat which when the solenoid coil is energised, moves off the
valve (direct operated) orifice or diaphragm (pilot operated) orifice opening the valve.
When the coil is de-energised, a return spring brings the plunger back to the original closing position,
thus cutting off the flow of the fluid.
546

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

TECHNICAL
INFORMATION

BASIC COMPONENTS
OF A SOLENOID VALVE
Valve body:

Main part of the solenoid valve including ports, seat and orifices.

Solenoid tube
assembly:

Cylinder, in stainless steel, hermetically sealed and closed at one extremity.


It is the guide channel of the moveable plunger which is moved magnetically.
The solenoid coil is fitted on the external side of the enclosing tube.

Moveable plunger:

Made by ferritic stainless steel, it is attracted by the solenoid magnetic


field and slides inside the tube.

Plunger spring
(or return spring):

Used to hold the moveable plunger in position and to return it when


de-energized.

Seat seal:

Part of the moveable plunger, it is used to close a valves main orifice


or pilot orifice.

Electromagnet
(or solenoid coil):

Electrical part consisting of a copper windings (solenoid) along,


with a magnetic yoke (armature), when electric current flows through,
it generates a magnetic field atracting the moveable plunger.

Housing:

Part that contains and protects the coil.

Yoke:

Metalic case surounding the coil and concentring electro-magnetic force


on the moveable plunger.

Solenoid tube assembly


Housing

Yoke

Solenoid coil

Moveable plunger

Plunger spring

Seat seal

Valve body

547

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

TECHNICAL
INFORMATION

TECHNICAL VOCABULARY USED IN TABLES

Actuation

Body

Port
Size

Function

Orice
(mm)

Flow
Factor
Kv(l/min)

MOPD
(bar)

Max
Fluid
Temp. (C)

Page

Page

Parker
Valves

Parker
LUCIFER
Valves

NORMALLY CLOSED
Port
size

Orice

BSP

mm

Flow
factors

Operating
Fluid
Pressure
Temp.
Differential
Min Max(MOPD) Min Max
Kv
KV
Qn
AC DC
l/min m3/h l/min bar bar bar C
C

Parker LUCIFER
Valves

Seat
Seal
Valve
Ref.

Housing
Ref.

Coil
Ref.

Power

AC
W

Coil
Group

Dwg.
No.

DC
W

The basic technical features of each solenoid valve are indicated in the tables, the terminology used
is shown and explained below. Please notice that in certain sections you will have the choice between
two product ranges: Parker valves, within blue tables and the Parker Lucifer valves, within orange tables.

Actuation:

The mechianical method used to control the flow.

Body:

Main part of the solenoid valve with the ports, seats and orifice
needed.

Function:
Port Size:

The way the valve operates when de-energised.


Fitting dimensions are defined as threaded in inches (G), in BSP
or Sub-base, when a flat interface for ports is adopted.

Orice (mm):

Main orifice diameter in millimetres (nominal diameter).

Flow Factors:

Define the quantity of water which flows through the solenoid valve
with a pressure drop of 1 bar during one minute.
Expressed in l/min and m3/h.

Max Fluid Temperature:

Maximum fluid temperature the valve can withstand.

Max Ambient Temperature:

Maximum ambient temperature the valve can withstand.

Minimum Operating
Pressure Differential:

The lowest differential pressure required for operation (bar).

Maximum Operating
Pressure Differential
(MOPD):

The highest working differential pressure with 90% of the rated voltage
(-10% Vn) applied to the solenoid coil (for AC) and 95% of the rated
voltage (-5% Vn)(for DC).

548

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

TECHNICAL
INFORMATION

NORMALLY CLOSED
Port Orice
size

BSP

mm

Flow
factors

Operating
Fluid
Seat
Pressure
Temp.
Seal
Differential
Min Max(MOPD) Min Max
Kv KV Qn
AC DC
3
3
l/min m /h m /h bar bar bar C C

Power

Parker Valves
Valve Order
Number

Valve
Type

Coil
Type

AC
W

Coil
Group

Dwg.
No.

DC
W

Fluid Temperature:

Minimum and Maximum admissible temperature


for the media used (C).

Seat seal:

Material used for the seat discs.

Valve order number:

Applicable for Parker Valves shown in blue tables.


The valve order number refers to the valves only.
(please refer to the "How To Order" section for more details).

Valve ref.:

Applicable for Parker Lucifer Valves shown in orange tables.


The valve ref. refers to the valve.
(please refer to the "How To Order" section for more details).

Valve type:

Refers to the Parker valve type

Housing ref.:

Only for Parker Lucifer valves shown in orange tables, you can choose
the housing to protect the coil.

Coil Ref.:

Compatible coil reference.

Coil type:

Compatible coil advised.

Power:

Power consumption of a specific electrical part on selected pressure


vessel, rated by AC and DC (W). Power consumption must be
considered in cold conditions for the coil, at TAmb: +20C.
For 483510, 481865 and 496081 series, power consumption indicated
in the tables must be considered in warm conditions.

Coil group:

Please refer to the specific section for the coil compatibility groups.

Dwg. No.:

Drawing number.

549

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

TECHNICAL
INFORMATION

TECHNICAL INFORMATION

Solenoid valves are highly engineered products that can be used in many diverse applications.
In addition to operational functionality, media compatibility and suitability for the operating environement
when selecting the best product for a given application.
This section provides a brief overview of the components, actuation and function modes of solenoid
valves avaible from Parker Hanninfin - FCDE.

Different Technologies:
Solenoid valves are electrically operated devices used to control flow.
The most common types of solenoid valve are:

Direct Operated
Valves

Magnalift Valves

Pilot Operated
Valves

550
50

Parker Hannin Corporation


Fluid Contro
Control Division Europe
General Catalogue FCDE
FCDE/0110/UK/V1.0

TECHNICAL
INFORMATION

DIRECT OPERATED VALVE

Magnetic force is used directly to open or close the plunger which controls the passage of the fluid.
Performances are limited by the coil, the pressure, and the valve orifice size. For direct operated valves,
the minimum working pressure is 0 bar and the maximum pressure relies on the combination (valve/coil)
chosen.

Direct Operated Valve


De-energised

Energised

Example:

121 Series
146 Series
N74 Series
551

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

TECHNICAL
INFORMATION

PILOT OPERATED VALVE

To control a higher flow, it is necessary to use pilot operated valves. The supply pressure enters
the direct operated "pilot stage" which directs the flow to a "pilot chamber" which,in turn, applies
the pilot pressure over a large area (generally a diaphragm or piston). Therefore, a large force is
generated to move the main sealing elements against higher pressure or over a large orifice.
One condition of operation is to have a minimum pressure available to shift the valve (indicated in
the catalogue). In most applications, this presents no particular problems (refer to magnalift valve
section). The pressure rating of the valve starts between 0.1 to 0.5 bar (depending on the valve).
(NB. Pilote Operated Valves are also called Servo Operated Valves).

Pilot Operated Valve


De-energised

Energised

Example:

321 Series
7321B Series
168.1 Series
552

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

TECHNICAL
INFORMATION

MAGNALIFT VALVE

The magnalift valves combine the features of the direct operated and pilot operated valves.
A mechanical link between the plunger and diaphragm retainer allows the valve to operate as
a direct operated valve at low pressures and as a pilot operated valve at higher pressures.
Magnalift valves are specially designed for applications where 0 pressure is needed to operate
the valve, as well as bigger flow than a direct operated valve.

Magnalift Operated Valve


De-energised

Energised

Example:

221 Series
123 Series

553

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

TECHNICAL
INFORMATION

NORMALLY CLOSED VALVE

Most of our valves are available in normally closed and normally open configuration when not
energized. In certain applications, you may require a normally open valve (open function in case
of current failure). The differentiating factor of design of this technology, is based upon the design
of the seat seal, which is reversed in comparaison to a normally closed valve.

Normally Closed Valve


De-energised

Energised

Example:

121 Series
146 Series
N74 Series
554

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

TECHNICAL
INFORMATION

NORMALLY OPEN VALVE

Normally Open Valve


De-energised

Energised

Example:

122 Series
136 Series
7322B Series
555

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

TECHNICAL
INFORMATION

FLOW AND PRESSURE RANGES

Area of operation:
Each valve principle, as described in the previous pages, has a defined area of operation related to its
pressure and flow capabilities. The following graph shows which type of valve is suitable for a certain
situation.

Orifice (mm)
100
75
50

25
20
15
14

Q Direct Operated
10

Q Magnalift

Q Pilot Operated
5
4

1
0 0.1

0.2 0.3

0.5

10

16 20

40

60

Pressure Max (bar)


100

Areas of operation of Parker solenoid valves.

556

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

TECHNICAL
INFORMATION

SIZING SOLENOID VALVES

The correct choice of solenoid valve is essential as it determines the regulation and performance
required for practical application on a system. In order to decide on the exact type of solenoid valve,
various parameters have to be known.
However the calculation method, based on the flow coefficient Kv, has proved highly practical as it can
be determined on the basis of:
O
O

Required flow rate


Flow resistance

O
O

Type of fluid and relative viscosity


Specific gravity and temperature

This flow coefficient Kv is determined as defined in the VDI/VDE 2173 standards.


It represents the flow of water in m3/h or L/min with a temperature from 5 to 30C which passes
through the solenoid valve with a pressure drop of 1 bar.
Note:
The ow coefcient
used in the USA is
known as Cv and
represents the water
ow rate in US gallons
per minute with a
pressure drop P
of 1 psi.

Ps

Sp

VE1
Rs

P1

P2

1-D

10 - D

20 - D

Nr

To convert Cv in Kv
and vice versa use:
1 Kv = 0.862 Cv
1 Cv = 1.16 Kv

15 - D

Vs

Cr
Mp

FG

FG = Grid Filter

Mp = Pump

Vs = Safety Valve

Nr = Check Valve

Sp = Pressure Tank

Ps = Static Pressure Manometer

After existing conditions have been converted into this factor Kv, the type of valve is found by referring
to the pages in the related sections in this catalogue.
Parameters used for selecting the solenoid valve are in the table next page.
Consult conversion tables of the various units of measurement as defined by the ISO
(International Standards Organisation) - I.S. (International System) set out in this catalogue.
557

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

TECHNICAL
INFORMATION

FLOW AND PRESSURE RANGES

Pressure
symbol
unit of measurement
Working pressure

Temperature of the medium


symbol
(t)
unit of measurement
[C]

(P)
[bar]

Flow rate

Pressure drop
symbol
(P)
unit of measurement
[bar]
Pressure difference between inlet (P1)
and outlet (P2) of the solenoid valve when
a medium is flowing through the valve
(P = P1 - P2).
Flow cfcient
symbol
unit of measurement

for liquids
symbol
unit of measurement

(Kv)
[m3/h]

Specic gravity of the medium


symbol
( a)
unit of measurement
[Kg/dm3]

(Q)
[m3/h]

for gases
symbol
unit of measurement

(Qn)
[Nm3/h]

for steam
symbol
unit of measurement

(Qv)
[Kg/h]

Specic volume
symbol
unit of measurement

(Vs)
[m3/Kg]

a) Solenoid valves for liquids:


Flow rate:

Flow coefcient:
Kv = Q

6P
a

Q = Kv

where: Q = m3/h
6P = bar
a = Kg/dm3

a
6P

In the case of liquids with viscosity greater than 3E (22 cStokes) the Kv is modied according to
the formula:
Kv1 = Kv + C

C=b

Kv + 1

200 Q
where C is the viscosity correction factor calculated by means of the formula:
where:
b = kinematic viscosity of the uid expressed in centistokes
Kv = ow rate factor of the solenoid valve
Q = ow rate in m3/h.

Pressure drop:
6P = a ( Q )2
Kv

558

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

TECHNICAL
INFORMATION

b) Solenoid valves for gases:


If 6P 1/2 P1 use the following formulae:
Flow rate: Qn = 514 Kv

where: Qn = Nm3/h

2
Pressure drop: 6P = (273 + t) a n Qn
P2
(514 Kv)2

6P P2
a n (273 + t)

P1 = bar

Flow coefcient: Kv = Qn
514

P2 = bar

If 6P > 1/2 P1 use the following formula:

(273+t) a n
6P P2

Qn = 757 Kv

6P P2
(273 + t) a n

t = C
a n = Kg/m3

c) Solenoid valves for steam:


If P 1/2 P1 use the following formulae:
6P
Flow rate:
Qv = 31,7 Kv
Vs

where: Qv = Kg/h

6P = bar

Pressure drop:

6P = Vs

Qv2
(31,7 x Kv)2

If P > 1/2 P1 use the following formula:

Vs = m3/Kg

Qv = 22,4 KV

Flow coefcient: Kv = Qv
31,7

Vs
6P

P1
VS

Notes:
1) Should the value P not be specied, use the following, which is based on experience:


For liquids only in the case of free discharge P = 90% of the input pressure (P1).

For gases never use a P of more than 50% of the absolute inlet pressure, since the excessive
pressure drop may cause an irregular flow rate. In most cases, P can be considered as 10%
of the input pressure.

2) Specic volume value (Vs) for dry saturated steam, see the table in diagram 3.
559

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

TECHNICAL
INFORMATION

FLOW RATE FOR LIQUIDS

The liquid ow through a pipe or a valve is given by:

Q = Kv
Where

6P

= Flow [l/min]

P = Differential Pressure [bar]

= Density of the fluid [kg/dm3]


(water a = 1 [kg/d m3])

kv = Flow Factor [m3/h]

Flow factor kv:

Maximum ow rate Qmax.

The kv flow factor of a valve is defined as


the flow rate of water in litres per minute with
a pressure drop of 1 bar across the valve.

For particular 2-way valves the maximum flow


must be limited for reasons of mechanical
resistance and durability.

Valve manufactuerers use different definitions


for kv. It may be expressed in l/h or m3/h.

A very high flow velocity may dislocate a popet


sealing or a diaphragm.

Care should therefore be taken when comparing


values.

Maximum flow rates are indicated in the catalogue.

Flow
factors
Qn
Kv
KV
l/min m3/h l/min

NORMALLY CLOSED
Port
size

BSP

Orice

mm

Flow
factors

Operating
Fluid
Pressure
Temp.
Differential
Min Max(MOPD) Min Max
Kv
KV
Qn
AC DC
l/min m3/h l/min bar bar bar C
C

Seat
Seal

Parker LUCIFER
Valves
Valve
Ref.

560

Housing
Ref.

Coil
Ref.

Power

AC
W

Coil
Group

Dwg.
No.

DC
W

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

TECHNICAL
INFORMATION

Speccic gravity of process uid


a [Kg/dm3]

Flow cfcient
Kv [m3/ h]

1.8

24
20
15
12
10
8
6

1.6

1.4

1.2

1
0.9

0.7

0.30

0.5

0.20

40

60
50
40
30
24
20
15
12
10
8
6

30
25
20
15

10
9
8
7
6

4
3
2

0.40

0.6

Pressure drop
6P[bar]

120

1
0.80
0.60

0.8

Flow rate
Q [m3/ h]

0.10

1
0.80
0.60

0.40
0.30

2.5

0.20
1.5

0.060
0.10

0.040
0.030

0.060

0.020
0.016
0.012
0.010

0.040
0.030

1
0.9
0.8
0.7
0.6

0.020
0.016
0.012
0.010

0.006

0.5
0.4

0.006

0.3
0.25

Auxiliary Line

0.2
0.15

0.1

Monogram for liquid ow calculation

Specic gravity of the most common uids ( a = Kg/dm3 ) - (t = 15C - P = 760 mm Hg)
Acetone

0.76

Benzenol

0.90

Naphtha

0.76

Water

1.00

Beer

1.02

Pentane

0.63

Sea water

1.02

Hexane

0.66

Vegetable oil

0.92

Ethyl alcohol

0.79

Ethane

0.68

Hydraulic oil

0.92

Methyl alcohol

0.81

Diesel oil

0.70

Wine

0.95

Petrol

0.68

Milk

1.03

561

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

TECHNICAL
INFORMATION

FLOW RATE FOR GASES

The gas ow through a valve is given by:

Q = C P1 kT
Where

t aair / agas

= Flow Rate [dm3/s]

= Conductance [dm3/s.bar]

P1 = Inlet Pressure [bar abs]

= Specific Weight [kg/m3]

kT = Temperature Correction Factor

1 -- P2/P1 -- b
1 -- b

t=

293
273 + Temp. C

kT =

Nominal Flow Qn:


Calculations can be made with specific flow factors based on the CETOP RP 50P standard.
For practical purposes and ease of valve selection the catalogue shows the nominal flow Qn.
The nominal flow Qn is defined as the flow rate (L/min) of air across the valve when the inlet
pressure P1 = 6 bar and the pressure drop P = 1 bar.
N.B.
The values of the flow factors and flow rates mentioned in catalogues are subjet to +/-15% tolerances.

Pneumatic application:

aair / agas = 1

a) Choked ow conditions P2 b.P1


in this case t = 1 --> Q = C . P1 . kT
b) Free ow conditions P2 > b.P1
in this case --> Q = C . P1 . kT . t
562

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

TECHNICAL
INFORMATION

a
(Kg/dm3)

t
(C)

Kv

6p
(bar)

Q
(m3/ h)
0.1 0.2 0.3 0.5

2 345

10 20

50 100

100000

80

50000

3
-50

10

5000
3000
2000

5
3
2

1000

300
200

+50

1
0.8
0.6
0.4
0.3

+100

0.2

0.4

100

0.1
0.08

0.2

50
30
20

50

10000

30
20

60

30000
20000

60

40
30
25
20
16

500

0.1

12
10
8
6
80
60
50
40
30
25
20
16
12
10
8
6
5
4
3
2
1.5
1
0.5
0.2
0

10
5
3
2

0.02
0.01
0.006

1
0.5
0.3
0.2
0.1

5
4
3
2

P 1 (bar)

1.5
.5
1
0.5
.2
0.2
0

Auxiliary Line

Auxiliary Line

Auxiliary Line

Critical speed

t = Fluid Temperature a N = Specic Gravity Kv = Flow Cfcient Qn = Flow Rate

p = Pressure Drop

P1 = Inlet Pressure

Specic gravity of the most common gases ( a = Kg/m3 ) - (t = 0C - P = 760mm Hg)


Acetylene
Carbon dioxide
Air
Argon
Nitrogen
Butane

1.176
1.965
1.293
1.780
1.255
2.000

Helium
Ethane
Ethylene
Hydrogen

0.179
1.035
1.259
0.089

563

Natural gas
Methane
Carbon monoxide
Oxygen
Propane
Steam

0.723
0.722
1.250
1.429
1.520
0.805

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

TECHNICAL
INFORMATION

TECHNICAL INFORMATION
Diagram 3 for Dry Satured Steam

Steam (Dry Satured) Data


P2 bar

0.02

0.01
0.03

0.06
0.1

0.1

10

0.2
0.2

0.5

50

1
0.5

100

2
3
4
5

0.04
0.05

500

1.5

10
1000

20

30

4
5

0.06
0.07
0.08
0.09

50

0.1

5000
10

100
10000

15

200
300

20

400

30

0.15

0.2

500

50000

30
26

28
24

22
20
18
16
14
12

1000
50

0.3

100000

0.4

10
9
8
7

Temp. C Vs m3/Kg

0.01

6.6

131.600

10.00

179.0

0.200

0.02

17.1

68.300

110.00

183.2

0.181

0.03

23.7

46.500

120.00

187.1

0.176

0.04

28.6

35.500

13.00

190.7

0.155

0.05

32.5

28.700

14.00

194.1

0.144

0.06

35.8

24.200

15.00

197.4

0.135

0.08

41.1

18.500

16.00

200.4

0.126

0.10

45.4

15.000

17.00

203.4

0.119

0.20

5 9.7

7.800

18.00

206.2

0.113

0.30

68.7

5.330

19.00

208.8

0.107

0.40

75.4

4.070

20.00

211.4

0.102

0.50

80.9

3.300

22.00

216.2

0.093

0.60

85.5

2.790

24.00

220.8

0.085

0.70

89.5

2.410

26.00

225.0

0.079

0.80

93.0

2.130

28.00

229.0

0.073

0.90

96.2

1.910

30.00

232.8

0.068

1.00

99.1

1.730

32.00

236.4

0.064

1.50

110.8

1.180

34.00

239.8

0.060

2.00

119.6

0.900

36.00

243.1

0.057

2.50

126.8

0.730

38.00

246.2

0.053

3.00

132.9

0.620

40.00

249.2

0.051

3.50

138.2

0.530

45.00

256.2

0.045

4.00

142.9

0.470

50.00

262.7

0.040

4.50

147.2

0.420

55.00

268.7

0.036

5.00

151.1

0.380

60.00

274.3

0.033

5.50

154.7

0.350

65.00

279.6

0.030

6.00

158.1

0.320

70.00

284.5

0.028

6.50

161.2

0.300

80.00

293.6

0.024

7.00

164.2

0.280

90.00

301.9

0.021

7.50

167.0

0.260

100.00

309.5

0.018

8.00

169.6

0.250

150.00

340.5

0.011

8.50

172.1

0.230

200.00

364.2

0.006

9.00

174.5

0.220

225.00

374.0

0.003

9.50

176.8

0.210

100
0.5

500000
200

P2 bar

0.05

0.3

Temp. C Vs m3/Kg

0.6

1000000

0.7
300

0.8

Auxiliary Line

0.6
1

1.5
1
2
2.5
0.5

Kv = Flow Coefficient

Qv = Flow Rate

p = Pressure Drop

564

Vs = Specific Volume

P2 = Outlet Pressure

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

TECHNICAL
INFORMATION

VISCOSITY CONVERSION TABLE

Centistokes
cStokes mm/S

Engler
E

Saybolt Universal Second


SSU

Rewood Second N1
SRW N1

12

65

55

22

100

90

30

140

120

28

175

155

45

210

185

60

275

245

75

10

345

305

90

12

415

370

115

15

525

465

150

20

685

610

200

26

910

810

300

39

1 385

1 215

400

53

1 820

1 620

500

66

2 275

2 025

750

97

3 365

2 995

1 500

197

6 820

6 075

OTHER USEFUL FORMULAS

Formulas:

Examples:

= (F - 32) x 5/9

(167F-32) x 5/9

= 75C

= (C x 9/5) + 32

(30C x 9/5) + 32

= 86F

m /h

= l/min x 0.06

100 l/min x 0.06

= 6 m3/h

l/min

= m3/h x 16,67

9 m3/h x 16,67

= 150 l/min

-4

= 5 m3/sec

m /sec

= m /h x 2,778 x 10

18.000 m /h x 2.778 x 10 -4

m3/sec

= l/min x 1,667 x 10-5

479.904 l/min x 1.667 x 10-5 = 8 m3/sec

565

Parker Hannin Corporation


Fluid Control Division Europe
CH-1227 Carouge-Genve
General Catalogue FCDE/0110/UK/V1.0

APPENDIX

566

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

APPENDIX

APPENDIX

567

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

APPENDIX

TABLE OF SUB-BASES FOR VALVES (Examples)


This table is showing examples of existing Sub-bases and possible Valves associations.
For more detail see sub-bases drawings in the following pages.
Sub-Base
Reference

488860.01
/.02/.03
/.04/.05

486162
/63/64

487165
/67/69

485635
/36/37

481168.02
/.04/.06
/.08/.10

481964.04
/.06/.08/.10

485291

485290

XGSPG1
/XGSPG2

Drawing

Valve
Reference
131F4480

131F4480

131F46

O
O

131F4650
131M74

131M74

131M7450

131M7450

131M75

131M7550

132F43

132F44

132F46

133F46

133F4650

2019F1

3019F1

O
O

301XGR
341F34

341F3403

O
O

341L11

341L2190
O

341L9101
O

345F34

347L11
O

E131F26
E131F43

E131F4350

E131F44

E131F4450

E133F43

E133F4350

E133F44

E133F4450

O
O

E331L21

568

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

APPENDIX

TABLE OF SUB-BASES FOR VALVES (Examples)

Drawing 1

Drawing 2
569

Quantity
of Valves by
Assembly

Reference
Numbers

A
mm

B
mm

Weight
g

1
2
3
4
5

488860-01
488860-02
488860-03
488860-04
488860-05

23.5
47.0
70.5
94.0
117.5

16.0 0.1
39.5 0.1
63.0 0.1
86.5 0.1
110.0 0.1

25
45
70
120
120

Quantity
of Valves by
Assembly

Reference
Numbers

A
mm

B
mm

Weight
g

2
3
5

486162
486163
486164

93
126
192

79
112
178

150
210
420

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

APPENDIX

TABLE OF SUB-BASES FOR VALVES (Examples)

Drawing 3

Drawing 4
570

Quantity
of Valves by
Assembly

Reference
Numbers

A
mm

B
mm

Weight
g

1
2
3

487165
487167
487169

56
89
188

44
77
176

85
135
300

Quantity
of Valves by
Assembly

Reference
Numbers

A
mm

B
mm

Weight
g

2
3
5

485635
485636
485637

128.2
178.7
279.7

115.0
165.5
266.5

1000
1400
2250

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

APPENDIX

TABLE OF SUB-BASES FOR VALVES (Examples)

Drawing 5

Drawing 6
571

Quantity
of Valves by
Assembly

Feeder
Reference

A
B
C
D Sealing Screw Set No.
mm mm mm mm 487758 481169* 481206

2
4
6
8
10

481168.02
481168.04
481168.06
481168.08
481168.10

72
120
168
216
264

Quantity
of Valves by
Assembly

Feeder
Reference

A
B
C
D Sealing Screw Set No.
mm mm mm mm 487758 481169* 481206

4
6
8
10

481964.04
481964.06
481964.08
481964.10

184
260
336
412

78
126
174
222
270

174
250
326
402

102
150
198
246
294

225
301
377
453

123
171
219
267
315

204
280
356
432

4
8
12
16
20

8
12
16
20

2
4
6
8
10

4
6
8
10

1
1
1
1
1

1
1
1
1

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

APPENDIX

TABLE OF SUB-BASES FOR VALVES (Examples)

Drawing 7

Drawing 8
572

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

APPENDIX

TABLE OF SUB-BASES FOR VALVES (Examples)

N2 Fixing holes M5 x 0.8

15

24

24

A*

A*

16
8

N4 Fori M4 x 0.7
N4 Holes M4 x 0.7

34

34
40

Port

Kit
Reference

To be used
with

Box
Quantity

Screws

1/8"G
1/4"G

XGSPG1
XGSPG2

Any version
Any version

10
10

Included
Included

Drawing 9
573

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

APPENDIX

INDEX FOR VALVES


Valve Reference
U
U
U
U
U
U
U
U
PM
PM
E
E
E
E

E
E
E
E
E
E

E
E

Page

Valve Reference

Page

330
033X0111
400
033X5152
400
033X5156
400
033X51561D
402
033X5195
404
033X5256
404
033X52561D
402
033X7156
186
120.4AR
186
120.4IR
188
121F2523
42,146
121F43
42,92
121F4302
42
121F4317
42,146
121F44
42,92
121F4406
42
121F4417
42
121F47
42,146
121F4706
42,146
121F63
42,146
121F64
42,146
121F67
184
121G2320
184
121G2520
184
121G2523
34,84
121K01
128
121K0103
34,84
121K0106
128
121K0113
34,84
121K0150
34,84
121K02
34,84
121K0250
34,142,144
121K03
34,84
121K0302
128
121K0323
34,84
121K0352
34
121K0397
32,142
121K04
32,84
121K0402
32
121K0497
32
121K07
32,84
121K0706
32
121K1302
32,142
121K14
32,142
121K23

121K2423
121K3106
121K3206
121K3303
121K3306
121K3321
121K45
121K4503
121K46
121K4603
121K6220
121K63
121K64
121K6423
121K65
121K67
121M13
121M14
121V5106
121V5112
121V5163
121V5206
121V5212
121V5263
121V5306
121V5363
121V5397
121V5406
121V5463
121V5497
121V5595
121V5596
121V55961D
121V5706
121V5763
122F44
122K83
122K8306
122K8321
122K8363
122K84
122K8406
122K8408
122K9321
122K9363

184
36,86,144
36,86,144
128
36,86,144
184
36,86
128
36,86
128
184
34,142
34,144
184
32,142
32,142
32,84
32,84
160
160
130,160
160
160
130,160
158
130,158
160
158
130,158
158
170
170
170
158
130,158
44
40
40,86
188
40,144
40,144
40
40,144
188
40,144

E
E
E
E
E
E
E
E

U
U
U

Valve Reference

Page

122V8306
123AV
123CV
123DV
123IV
125BV
125CV.2
125K01
125K03
126YH
126YT
128GR
128IR
128ISV
128IV
131.4BV
131.4CG
131.4FV
131.4GG
131.4GV
131AN
131B04
131B14
131E03
131F26
131F43
131F4350
131F4397
131F44
131F4410
131F4450
131F4490
131F4497
131F46
131F4650
131F5295
131F5406
131F5695
131F56951D
131IN
131INDIN
131IV
131K03
131K0308
131K0350

162
46
46
46
46
90
90
40,88
40
126
126
226
226
226
226
178
180
180
180
180,182
178
234
234
216,306
238
230
230
312
230
228
230
228
228
230
230
384
236
384
384
178
178
178
216
216,306
216,306

PM
PM
PM
PM
PM
PM

PM
PM
PM
PM
PM
PM

E
E
E
E
E
E

U
U
U

E
E
E
574

Valve Reference
E
E
E

E
E
E
E

E
E
E
E

U
U

131K0358
131K0397
131K04
131K0450
131K0490
131K0497
131K06
131K0648
131K0650
131K13
131K14
131K16
131K1650
131K63
131K6350
131K64
131K6450
131M14
131M15
131M74
131M7450
131M75
131M7550
131T21
131T2101
131T22
131T23
131T2301
131T29
131T2901
131V5306
131V5363
131V5397
131V5406
131V5463
131V5490
131V5497
131X1101
131X1101
131X1131
131X1201
132F43
132F44
132F46
132K03

Page
210,302
210,214
212,304
212,304
210,302
212,304
214,304
272
214,304
210
210
210
210
216
216
212
212
210,302
210,302
228
228
228
228
216
306
216
212
212
214
214
252
252
252
252
252
252
252
334
334
334
386
230
230
230
218

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

APPENDIX

INDEX FOR VALVES


Valve Reference

Page

132K04
132K06
132T22
132T23
132T2301
132T29
133F43
133F44
133F4450
133F46
133F4650
133K03
133K0350
133K04
133K0450
133K0497
133K05
133K06
133K0650
133K13
133K14
133K16
133T21
133T2101
133T23
133T2301
133V5306
133V5363
133V5406
133V5463
133V5595
133V55951D
133V5695
133V56951D
133V7595
133V7695
133X01
133X01
133X01001D
133X0111
133X01111D
133X0131
133X5152
133X5156
133X51561D

218
218
218
218
218
308
232
232
232
232
312
222
222
222
222
222
222
222
222
222
222
222
222
224
222
222
254
254
254
254
376
376
376
376
376
376
314
314
314
308
308
310
378
378
378

E
E
E

E
E
E
E
E
E
E
E
E
E

U
U
U
U
U
U
U
U
U
U
U
U
U

Valve Reference
U
U
U
U
U
U
U
U
U
U
PM
PM
PM
PM

PM
PM
PM
PM
PM
PM
PM
PM
PM
PM
PM
PM
PM
PM
PM
PM
PM
PM
PM
PM
PM
PM
PM
PM
PM
PM
PM
PM
PM

133X5192
133X5195
133X51951D
133X5196
133X51961D
133X5296
133X52961D
133X7156
133X7195
133X7196
135AT
135CT
135DT
135IT
135K03
135K04
136.2FV
136YV
139AV
139FV
139GV
139LV
140.4AR
140.4DR
140CR
140DR
140IR
141AV
141BV
141FV
141GV
146.3ABV
146.3KV
146BV
146FV
146HV
146WV
146YV
151GV
151HV
153BV
153GV
156.2AR
156.2CR
156.2DR

Page

Valve Reference

Page

Valve Reference

Page

378
384
386
378
380
382
382
380
386
380
134
136
136
134
310
224
38
38
220
220
220
220
180
180
126,180
126,180
126,178
208
208
208
208
30,82
30,82
28,80
28,30,80
30,80
30,82
30,82
38
38
182
182
134
136
136

PM 156.2IR
PM 158IH
PM 158IT
161.4AV
161.4BV
161.4EV
PM 168.1AN
PM 168.1CN
PM 168.1DN
PM 168.1IN
PM 169.1AN
PM 169.1CN
PM 169.1DN
PM 169.1IN
PM 173AN
PM 173IN
2019F1GRG7
2019F1GVG7
2019F1JRG7
2019F1JVG7
2019F1LRG7
2019F1LVG7
2019F1NRG7
2019F1NVG7
201LG1GVG2
201LG1JVG2
201LG1LVG2
201LG2GVG2
201LG2JVG2
201LG2LVG2
201LG2NVG7
201LG2PVG7
201LG3SVG7
201LG3UVG7
201LG4SVG7
201LG4UVG7
221G13
221G1303
221G1330
221G15
221G1503
221G1530
221G16
221G1603
221G1610

134
126
126
80
80
82
54
54
54
54
68
68
68
68
54
54
202
202
202
202
202,204
204
204
204
166
166
166
166
166
166
166
166
168
168
168
168
48
132
132
48
132
48
50
132
50

221G1630
221G1631
221G17
221G1703
221G1710
221G1730
221G1731
221G21
221G2103
221G2106
221G2110
221G2130
221G2131
221G2136
221G23
221G2330
221G25
221G2523
221G2530
221G26
221G2630
221G27
221G2730
221J3301E
221S10E
221S10F
221S15E
221S15F
221S20E
221S20F
221S25E
221S25F
3019F1GRG7
3019F1GVG7
3019F1JRG7
3019F1JVG7
3019F1LRG7
3019F1LVG7
3019F1NRG7
3019F1NVG7
301XGFRTG7
301XGFRTJ7
301XGFRTL7
301XGFRTN7
301XGFVTG7

50
50
52
132
52
52
114
52
114
52
52
52
114
52
48
48
48
190
48
50
50
52
52
198
172
172
172
172
172
172
174
174
258
258
258,260
260
260
260
262
262
258
260
260
262
258

575

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

APPENDIX

INDEX FOR VALVES


Valve Reference

Page

301XGFVTJ7
301XGFVTL7
301XGFVTN7
321F2523
321F32
321F3202
321F35
321G36
321G3606
321G3610
321G37
321G3706
321G3710
321G3790
321G38
321G3806
321G3810
321G39
321G3906
321G3910
321G3990
321G40
321G4006
321G4010
321G4090
321H11
321H13
321H15
321H1590
321H21
321H23
321H2322
321H25
321H2522
321H2523
321H35
321H36
321K10
321K13
321K1314
321K15
321K1503
321K1514
321K1523
321K1535

260
260,262
262
194
76,110
76,154
76
62,102
62
118
64,104
64
120
64
64,104
64
120
66,104
66
120
66
66,104
66
120
66
56,148
58,148
60,150
60
148,192
148,192
192
150,194
194
194
60
62
56,98
58,98
58,98
60,100
138
60,100
268
266

E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E

E
E
E
E
E
E

Valve Reference

321K1536
321K1537
321K1543
321K25
321K31
321K3106
321K33
321K3306
321K35
321K3506
321K36
321K3606
321K37
321K3706
321K4106
321K4156
321K4306
321K4356
321K4506
321K4556
321K4606
321K4656
321K4706
321K4756
321K63
322F35
322F72
322F7206
322G36
322G3606
322G3610
322G37
322G3706
322G3710
322G38
322G3806
322G3810
322G39
322G3906
322G3910
322G40
322G4006
322G4010
322G75
322G7506

Page

Valve Reference

268
268
266
60,100
56,98
56
58,98
58
60,100
60
62,102
62
64,104
64
98,118
56
98,118
58
100,118
100,118
102,118
102,118
104,120
104,120
148
76
76
76,154
72,108
72
122
72,110
72
122
72
72
122
72,110
72
122
72
72
122
70,108
70,152

E
E
E
E

E
E
E
E

576

322H35
322H36
322H71
322H7106
322H73
322H7306
322H75
322H7506
322K4106
322K4306
322K4506
322K4606
322K4706
325K4106
325K4306
325K4506
325K4606
325K4706
331B01
331B02
331B21
331B74
331B7490
331L21
331N03
331N04
331N0402
331N34
331N3402
332B01
332B02
332B21
341B01
341B02
341B21
341B34
341B3403
341B3440
341B3490
341F21
341F34
341F3403
341F3440
341L01
341L0197

Page
70
72
70
70,152
70,152
70,152
70,152
70,152
108
108
108
108
110
74
74
74
74
74
240
248
242
240
240
244
336
336
336
338
338
242
242
244
278
276
278
276
276
276
276
278
284
284
284
294
294

Valve Reference
E

E
U
E

U
U
U

341L02
341L04
341L05
341L11
341L1130
341L1130
341L21
341L2190
341L9101
341L9201
341L9504
341L9534
341L9594
341L9597
341L9598
341N01
341N02
341N0250
341N03
341N04
341N05
341N0502
341N11
341N12
341N21
341N2190
341N22
341N31
341N3102
341N3108
341N3128
341N3130
341N3190
341N3196
341N3197
341N32
341N3202
341N3250
341N3290
341N3292
341N3295
341N3296
341N3297
341N34
341N35

Page
292
294
294
290
290
290
286
286
282
286
362
362
364
364
364
340
346
396
350
350
344
346
340
348
340
340
348
342
342
342
342
342
342
342
342
348
348
394
344
394
394
344
344
350
346

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

APPENDIX

INDEX FOR VALVES


Valve Reference

U
U

341N3502
341P01
341P02
341P0250
341P03
341P04
341P21
341P2108
341P2190
341P2197
341P22
341P2290
341P2297
341P3250
341P3292
341P3295
341P33
341P34
342N03
342N11
342N3197
342N33
343N03
345B04
345B24
345B34
345F34
345L01
345L21
345N31
345P21
347L04
347L11
347L1130

Page
346
316
318
388
318
322
316
316
318
316
320
320
320
388
390
390
318
322
358
358
358
358
360
280
280
280
284
296
288
362
328
288
292
292

Valve Reference

U
U

347L9101
347L9201
347N03
347N04
347N11
347N12
347N31
347N3190
347N3197
347N32
347N3250
347N33
347N34
347P01
347P02
347P03
347P04
347P21
347P2190
347P2197
347P22
347P3250
347P3295
347P33
347P34
421F35
441P3250
531N03
531N04
541L01
541N01
541N0108
541N03
541N04

Page

Valve Reference

Page

Valve Reference

Page

282
288
354
356
352
354
352
352
352
354
398
354
356
324
326
326
328
324
324
324
326
392
392
326
328
76
388
366
366
298
368
368
370
370

542N03
547N03
7321BAH00
7321BAN00
7321BAN01
7321BAV00
7321BCH00
7321BCN00
7321BCN01
7321BCN02
7321BCV00
7321BDH00
7321BDN00
7321BDN01
7321BDN02
7321BDV00
7321BEH00
7321BEN00
7321BEN01
7321BEN02
7321BFH00
7321BFN00
7321BFN01
7321BFN02
7321BGH00
7321BGN00
7321BGN01
7321BGN02
7321BIH00
7321BIN00
7321BIN01
7321BIV00
7321BLN02
7321BMN02

372
370
94
94
94
94
94
94
94
116
94
94
94
94
116
94
96
96
96
116
96
96
96
116
96
96
96
116
94
94
94
94
116
116

7322BAH00

106

7322BAN00

106

7322BAV00

106

7322BCH00

106

7322BCN00

106

7322BCV00

106

7322BDH00

106

7322BDN00

106

7322BDV00

106

7322BEH00

106

7322BEN00

106

7322BFH00

106

7322BFN00

106

7322BGH00

106

7322BGN00

106

7322BIH00

106

7322BIN00

106

7322BIV00

106

7322BLN06

106

7322BMN06

106

N74.4AV

28

N74.4AVA.5

28

N74.4BV

28

N74.4FV

28

N74.4IV

28

N74.4WV

30

N79.4AV

208

N79.4IV

208

N79.6AV

208

N79.6BV

208

N79.6IV

208

WARNING - USER RESPONSIBILITY


FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN
CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker-Hannin Corporation, its subsidiaries and authorized distributors provide product or system options
for further investigation by users having technical expertise.
The user, through its own analysis and testing, is solely responsible for making the nal selection of the system and components and assuring that all
performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application,
follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials
provided from Parker or its subsidiaries or authorized distributors.
To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specications
provided by the user, the user is responsible for determining that such data and specications are suitable and sufcient for all applications and
reasonably foreseeable uses of the components or systems.

577

Parker Hannin Corporation


Fluid Control Division Europe
General Catalogue FCDE/0110/UK/V1.0

Parkers
Motion &
Control
Technologies
At Parker, were guided
by a relentless drive to help
our customers become more
productive and achieve higher
levels of protability by
engineering the best systems
for their requirements.
It means looking at customer
applications from many angles
to nd new ways to create
value.

Aerospace

Climate Control

Key Markets

Key Products

Key Markets

Key Products

Aftermarket services
Commercial transports
Engines
General & business
aviation
Helicopters
Launch vehicles
Military aircraft
Missiles
Power generation
Regional transports
Unmanned aerial
vehicles

Control systems &


actuation products
Engine systems
& components
Fluid conveyance
systems & components
Fluid metering, delivery
& atomization devices
Fuel systems
& components
Fuel tank inerting systems
Hydraulic systems
& components
Thermal management
Wheels & brakes

Agriculture
Air conditioning
Construction Machinery
Food & beverage
Industrial machinery
Life sciences
Oil & gas
Precision cooling
Process
Refrigeration
Transportation

Accumulators
Advanced actuators
CO2 controls
Electronic controllers
Filter driers
Hand shut-off valves
Heat exchangers
Hose & ttings
Pressure regulating
valves
Refrigerant distributors
Safety relief valves
Smart pumps
Solenoid valves
Thermostatic expansion
valves

Whatever the motion and


control technology need,
Parker has the experience,
breadth of product and global
reach to consistently deliver.
No company knows more
about motion and control
technology than Parker.
For further info call
00800 27 27 5374

Hydraulics

Pneumatics

Key Markets

Key Products

Key Markets

Key Products

Aerial lift
Agriculture
Alternative energy
Construction machinery
Forestry
Industrial machinery
Machine tools
Marine
Material handling
Mining
Oil & gas
Power generation
Refuse vehicles
Renewable energy
Truck hydraulics
Turf equipment

Accumulators
Cartridge valves
Electrohydraulic actuators
Human machine
interfaces
Hybrid drives
Hydraulic cylinders
Hydraulic motors &
pumps
Hydraulic systems
Hydraulic valves &
controls
Hydrostatic steering
Integrated hydraulic
circuits
Power take-offs
Power units
Rotary actuators
Sensors

Aerospace
Conveyor & material
handling
Factory automation
Life science & medical
Machine tools
Packaging machinery
Transportation &
automotive

Air preparation
Brass ttings & valves
Manifolds
Pneumatic accessories
Pneumatic actuators
& grippers
Pneumatic valves
& controls
Quick disconnects
Rotary actuators
Rubber & thermoplastic
hose & couplings
Structural extrusions
Thermoplastic tubing
& ttings
Vacuum generators,
cups & sensors

Electromechanical

Filtration

Key Markets

Key Products

Key Markets

Key Products

Key Markets

Key Products

Aerospace
Factory automation
Life science & medical
Machine tools
Packaging machinery
Paper machinery
Plastics machinery
& converting
Primary metals
Semiconductor &
electronics
Textile
Wire & cable

AC/DC drives & systems


Electric actuators, gantry
robots & slides
Electrohydrostatic actuation
systems
Electromechanical actuation
systems
Human machine interface
Linear motors
Stepper motors, servo
motors, drives & controls
Structural extrusions

Aerospace
Food & beverage
Industrial plant
& equipment
Life sciences
Marine
Mobile equipment
Oil & gas
Power generation &
renewable energy
Process
Transportation
Water Purication

Analytical gas generators


Compressed air lters
& dryers
Engine air, coolant, fuel
& oil ltration systems
Fluid condition
monitoring systems
Hydraulic & lubrication
lters
Hydrogen, nitrogen
& zero air generators
Instrumentation lters
Membrane & ber lters
Microltration
Sterile air ltration
Water desalination &
purication lters &
systems

Aerial lift
Agriculture
Bulk chemical handling
Construction machinery
Food & beverage
Fuel & gas delivery
Industrial machinery
Life sciences
Marine
Mining
Mobile
Oil & gas
Renewable energy
Transportation

Check valves
Connectors for
low pressure uid
conveyance
Deep sea umbilicals
Diagnostic equipment
Hose couplings
Industrial hose
Mooring systems &
power cables
PTFE hose & tubing
Quick couplings
Rubber & thermoplastic
hose
Tube ttings & adapters
Tubing & plastic ttings

Process Control

Fluid & Gas Handling

Sealing & Shielding

Key Markets

Key Products

Key Markets

Key Products

Alternative fuels
Biopharmaceuticals
Chemical & rening
Food & beverage
Marine & shipbuilding
Medical & dental
Microelectronics
Nuclear Power
Offshore oil exploration
Oil & gas
Pharmaceuticals
Power generation
Pulp & paper
Steel
Water/wastewater

Analytical Instruments
Analytical sample
conditioning products
& systems
Chemical injection ttings
& valves
Fluoropolymer chemical
delivery ttings, valves
& pumps
High purity gas delivery
ttings, valves, regulators
& digital ow controllers
Industrial mass ow
meters/controllers
Permanent no-weld
tube ttings
Precision industrial
regulators & ow
controllers
Process control double
block & bleeds
Process control ttings,
valves, regulators &
manifold valves

Aerospace
Chemical processing
Consumer
Fluid power
General industrial
Information technology
Life sciences
Microelectronics
Military
Oil & gas
Power generation
Renewable energy
Telecommunications
Transportation

Dynamic seals
Elastomeric o-rings
Electro-medical
instrument
design & assembly
EMI shielding
Extruded & precision-cut,
fabricated elastomeric
seals
High temperature metal
seals
Homogeneous & inserted
elastomeric shapes
Medical device fabrication
& assembly
Metal & plastic retained
composite seals
Shielded optical windows
Silicone tubing
& extrusions
Thermal management
Vibration dampening

Parker Worldwide
AE United Arab Emirates,
Dubai
Tel: +971 4 8127100
[email protected]
AT Austria, Wiener Neustadt
Tel: +43 (0)2622 23501-0
[email protected]
AT Eastern Europe, Wiener
Neustadt
Tel: +43 (0)2622 23501 900
[email protected]

IE Ireland, Dublin
Tel: +353 (0)1 466 6370
[email protected]

North America

IT Italy, Corsico (MI)


Tel: +39 02 45 19 21
[email protected]

US USA, Cleveland
Tel: +1 216 896 3000

KZ Kazakhstan, Almaty
Tel: +7 7272 505 800
[email protected]

Asia Pacic

NL The Netherlands, Oldenzaal


Tel: +31 (0)541 585 000
[email protected]

AZ Azerbaijan, Baku
Tel: +994 50 2233 458
[email protected]

NO Norway, Asker
Tel: +47 66 75 34 00
[email protected]

BE/LU Belgium, Nivelles


Tel: +32 (0)67 280 900
[email protected]

PL Poland, Warsaw
Tel: +48 (0)22 573 24 00
[email protected]

BY Belarus, Minsk
Tel: +375 17 209 9399
[email protected]

PT Portugal, Leca da Palmeira


Tel: +351 22 999 7360
[email protected]

CH Switzerland, Etoy
Tel: +41 (0)21 821 87 00
[email protected]

RO Romania, Bucharest
Tel: +40 21 252 1382
[email protected]

CZ Czech Republic, Klecany


Tel: +420 284 083 111
[email protected]

RU Russia, Moscow
Tel: +7 495 645-2156
[email protected]

DE Germany, Kaarst
Tel: +49 (0)2131 4016 0
[email protected]

SE Sweden, Spnga
Tel: +46 (0)8 59 79 50 00
[email protected]

DK Denmark, Ballerup
Tel: +45 43 56 04 00
[email protected]

SK Slovakia, Bansk Bystrica


Tel: +421 484 162 252
[email protected]

ES Spain, Madrid
Tel: +34 902 330 001
[email protected]

SL Slovenia, Novo Mesto


Tel: +386 7 337 6650
[email protected]

FI Finland, Vantaa
Tel: +358 (0)20 753 2500
[email protected]

TR Turkey, Istanbul
Tel: +90 216 4997081
[email protected]

FR France, Contamine s/Arve


Tel: +33 (0)4 50 25 80 25
[email protected]

UA Ukraine, Kiev
Tel +380 44 494 2731
[email protected]

GR Greece, Athens
Tel: +30 210 933 6450
[email protected]

UK United Kingdom, Warwick


Tel: +44 (0)1926 317 878
[email protected]

HU Hungary, Budapest
Tel: +36 23 885 470
[email protected]

ZA South Africa, Kempton Park


Tel: +27 (0)11 961 0700
[email protected]

2012 Parker Hannin Corporation.


All rights reserved.

CA Canada, Milton, Ontario


Tel: +1 905 693 3000

AU Australia, Castle Hill


Tel: +61 (0)2-9634 7777
CN China, Shanghai
Tel: +86 21 2899 5000
HK Hong Kong
Tel: +852 2428 8008
IN India, Mumbai
Tel: +91 22 6513 7081-85
JP Japan, Tokyo
Tel: +81 (0)3 6408 3901
KR South Korea, Seoul
Tel: +82 2 559 0400
MY Malaysia, Shah Alam
Tel: +60 3 7849 0800
NZ New Zealand, Mt Wellington
Tel: +64 9 574 1744
SG Singapore
Tel: +65 6887 6300
TH Thailand, Bangkok
Tel: +662 186 7000-99
TW Taiwan, Taipei
Tel: +886 2 2298 8987
South America
AR Argentina, Buenos Aires
Tel: +54 3327 44 4129
BR Brazil, Sao Jose dos Campos
Tel: +55 800 727 5374
CL Chile, Santiago
Tel: +56 2 623 1216
MX Mexico, Apodaca
Tel: +52 81 8156 6000
Ed. 2012-06-19

Europe, Middle East, Africa

General Catalogue FCDE/0110/UK/V1.0 - 06/2012

EMEA Product Information Centre


Free phone: 00 800 27 27 5374
(from AT, BE, CH, CZ, DE, DK, EE, ES, FI, FR, IE, IL.
IS, IT, LU, MT, NL, NO, PL, PT, RU, SE, SK, UK, ZA)

US Product Information Centre


Toll-free number: 1-800-27 27 537
www.parker.com

Your local authorized Parker Distributor

You might also like